Loading...
14090184 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 10789 S, QU CONTRACTOR:ALLEN SIGNS INC PERMIT NO: 14090184 OWNER'S NAME: PACIFIC RIM PARK LLC 1982 STONE AVE DATE ISSUED:09/26/2014 OWNER'S PHONE: 4082554163 SAN JOSE,CA 95125 PHONE NO:(408)280-6500 LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL COMMERCIAL ❑ 22 /, HS2 ACADEMY-INSTALL(N)ILLUMINATED WALL SIGN License Class�� Lic.# �J`i' TO Contractor 'P/>n 51 Date (E)CIRCUIT I hereby affirm that I am licens d under the provisions of Chapler 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the f, performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$2000 {IC-L ;have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:36934052.10789 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct.I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DA IT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 DA M L LED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the granting of this permit. Additionally,the applicant understands and will comply ued by: I o with all non-point source regulations per the Cupertino Municipal Code,Section 9 18. � G RE-ROOFS: Signature Date [ u' All roofs shall be inspected prior to any roofing material being installed.If a roof is installed without first obtaining an inspection,I agree to remove all new materials for inspection. E] OWNER-WILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of Signature of Applicant: Date: the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER I,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) 1,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sections 25505,25533,and 25534. Section 3700 of the Labor Code,for the performance of the work for which this (.�� Date: permit is issued. Owner or authorized agent: I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct.I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 918. Signature Date SIGN PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION V` 10300 TORRE AVENUE•CUPERTINO, CA 95014-3255 CUPERTiNO (408)777-3228•FAX(408)777-3333•building aacupertino.org -61anev 4ve PROJECT ADDRESS (62"-A APN# z- 4) OWNER AME S S r l PHONE ftf-2 y41 E-MAIL STREET ADDRESS,,,J CITY,STATE,ZIP FAX CONTACT NAMEi PHONE / E-MAIL �b STREET ADDRESS V2 CITY,STATE,ZIP FAX Aiyne Ave- ❑ OWNER ❑ OWNER-BUILDER ❑ OWNER AGENT CONTRACTOR ❑CONTRACTOR AGENT ❑ ARCHITECT ❑ENGINEER ❑ DEVELOPER ❑TENANT CO =N LICENSE NUMBER W.-3 Qn-SP-0 7LICENSE TYPE BUS.LIC# .� COMPANY NAMEr E-MAIL FAX [ 1 STREET ADDRESSCITY,STATE,ZIP, J- PHON119E O _ ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS.LIC# COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE DESCRIPTION OF WORK K l t V►�I.L/�Y1. 'Ci�_ Sl USE OF ❑ SFD or Duplex .❑ Multi-Family ILLUMINATED SIGN TYPE NO.OF SIGN AREA VALUATION STRUCTURE: ❑ Commercial (Y/N) (CODE) SIGNS (SQ.FT-) h�..(s) SIGN TYPE CODES: ` 2 DO c) B - BANNER SIGN M - MONUMENT(GROUND)SIGN BL - BLADE SIGN P -PROJECTING SIGN D - DEVELOPMENT ID SIGN SP -SPECIAL EVENT BANNER DI - DIRECTIONAL SIGN T -TEMPORARY E - ELECTRONIC W -WALL SIGN READERBOARD WI -WINDOW SIGN TAL VALUATION: By my signature below,I certify to each of the following: I am the property owner or authorized agent Cadon the property owner's behalf. 1 have read this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to buildin c nstmctI . I authorize representatives of Cupertino to enter the above-' entified property for inspection purposes. Signature of Applicant/Agent: Date: a2-il a ,5 t SUPPLEMENTAL INFO TION REQUIRED rle Site Plan Prv�ca> ' F W w Elevations ES �'�'B DA`Is-.ptArt.)2EVIEw _Sign Details-including UL listing(s)applicableQP Structural Calculations(ifapplicable) LARGE �_g Copy of Planning Approval Letter or Meeting with Planning Prior to submittal of Building Permit application. SignApp_201 1.doc revised 03/16/11 CITY OF CUPERTINO FEE ESTIMATOR- BUILDING DIVISION 7ADDRESS: 10789 BLANEY AVE DATE: 09/26/2014 REVIEWED BY: MELISSA 36934052.10789 BP#: 14090184 VALUATION: $2,000 OPERM TYP E:: Building Permit PIAN('111'('K F)"i'f-: PRIMARYPENTAMATION 1 CEAP5 USE. Sign PERMIT TYPE: WORK HS2 ACADEMY- INSTALL N ILLUMINATED WALL SIGN TOE CIRCUIT SCOPE SIGN TYPE FEE ID QTY SIGN FEE Wall Sign,Electric 1SIGNWELEC 1 $286 TOTALS: $286.00 tlt,, Pion('yra,;,d; 1'I111ttb. Plan t'hcck #Branch Circuits 1 $48.00 t:'?';?tit f'>e' 1>lump, J•S�i:: IESIGN Elec.Permit Fee: IEPERMIT F e:rm7 ' };r;ar" , rrs? Olhei-Plumb lmo Other Elec.Insp. 0.0 $48.00 Phmib7 lnv). Fee: 1 pec.If t. 1're: NOTE: This estimate does not include fees due to other Departments(Le.Planning,Public Works,Fire,Sanitary Sewer District,School District,etc). These fees are based on the prelimina information available and are only an estimate. Contact the De t or addn'l info. FEE ITEMS(Fee Resolution 11-053 E . 7/1/13) FEE QTY/FEE MISC ITEMS Suppl. PC Fee: (E) Reg. Q OT 0.0 hrs $0.00 Permit Fee: $286.00 Suppl. Insp. Feer Reg. ® OT 10.0 hrs $0.00 PME Unit Fee: $48.00 PME Permit Fee: $48.00 Consfrl'wtio?z Tax: F 1 C/In I/I i�0-'�[i V PI? Work Without Permit? ® Yes (E) No $0.00 Sign Master Plan: 0 Yes (F) No $0.00 Travel Documentation Fee: ITRAVDOC $48.00 Strong Motion Fee: IBSEISMICO $0.56 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $1.00 5 $431.56 $0.00 TOTAL FEE: $431.56 sin Revised: 08/20/2014 STATE OF CALIFORNIA siGh UGt4TtNG CEC-NRCC 1LM01-$Revised o611 CAUFORMA ENERGY OQWA"ON CERTIFICATE OF COMPLIANCE—DATA FIELD DEFINITIONS AND CALCULATIMIS NRCC LT5-01-E Sigri Lighting (Page 1 of 41 Project Name: A43 2- Ai�deg-1Date Prepared: Project Address: D Location of Sign I0 Outdoor Signs ©Indoor Signs Phase of Sign Construction Ja New Signs Q Sign Alterations Type of Lighting Control ffi New Lighting Controls Q Replaced Lighting Controls Q Not installing Lighting Controls This Certificate of Compliance includes the follow toepr nts(cheek all that apply). Cl Mandatory Measures(Lighting Controls) 13 Maximum Allowed Lighting Rower ©Specific Lighting Sources DOCUMENTATION AU #f0R'SVECLAiVASt14ISfiM 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name Documentation gnatur_Qn company 5lgrrature Date Allen Si s Inc l Adoiress. CW HERS Certification l ottof 19e): 1982 Stone Ave city/state/z: Plume. Sian Jose,CA 95125 F 408-280-6500 RESPONSIM E PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury,under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division.3 of the Business and Professions,Code to accept responsibittty for the building design or system design identified an this Certificate of Compliance(responsible designer). 3. The energy features and performance specifications,materials,components,and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24,Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,worksheets,calculations,plans and specifications submitted to the enforcement agency for approval with this bu'►lding.perr It application. 5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permits)issued for the building,and made available to thii enforcemeint agency for all applicable inspections.l understand that a completed signed copy of this Certificate of Compliance Is required to be Included with the documentation the builder:provides to the building owner at occupancy. Responsible Designere: , Resport§ibleDesigner 1 t Company: _ Date Signed Allen Si S InC Iq Address: 1982 Stone Ave License: C45,834580 rlty/state/Zlp: Phone 40$-2$13-6500 San A 95125 CA Building Energy Efficiency Standards-2013 Nonresidential Compliance lune 201.3 STATE OF CALIFORNIA SIGN LIGHTING ` CEC-NRCC-LTS-01=E Revised 08113 CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE—DATA FIELD DEFINITIONSAND CALCULATIONS „ NRCC-LTS-01-E Sign Lighting (Page of 4) ProJea Name: Prepared� 3.Mandatory Sign Lighting Controls NOTES: 1. The some responsible person may install both the sign lighting power and the sign lighting controls,or a different responsible person. install the sign fighting controls than the'resporWbfe person installing the sign 4fiting power. 2. The Mandatory Mearstrres(sant lfglttng controls)are' for cw*libnce.�:Ii*s4a fighting Standards.. If the pemw responsible for installing the sign lighting power is not also responsible for the sign sighting,controls,then the owner of the sign, general contractor,or architect shad be responsible to have the sign lighting controls irwallecL 3. -f more.than one person has.responsibility for compliance, each,responsible person shall prepare and sign a Certificate of Compliance and an_fnstitrltation Cert*cote applicable to the portion of constrrlction film ey arae response;alternaMsely, the person with chief responsibility for.construction shalt prepare_cand sign the"Certificate of Compliance Declaration.Statement for the entire construction. 3a. statements of Responstbl'AV:Any person signing the Certificate of Compliance Declaration Statemeent an page 1 of 4 on this SLTG-1C shall complete Part 3a.Check Yes or No for all of the following statements: I have responsibility for installing the sign lighting cbntrol5 t Yes,complete_parts.3a and 3b.of.this form 0 No complete part 3a.ofthis form There are no existing sign lighting controls and 1 will be`installing compliant sign lighting controls $l Yes 13 filo 3 There are no existing sign lighting controls and someone else will be responsible to install compliant sign lighting controls Yes to filo There are existing sign lighting controls that do not comply with the applicable provision of§110.9 and§2301.3 and I will be 4 installing compliant sign lighting controls Q Yes 1Z No There are existing sign lighting controls that do not comply with the applicable provision of§110:9 and§130.3 acid someone --- S else will be responsible to install compliant sign lighting controls ❑Yes I No 3b.Mandatory-Sign iightlat controls If the person signing the Certificate of Compliance Declaration Statement on page 1 of 4 of this SLTCr1C is responsible for complying with the sighs lighting control`requirements,.that person shall'ahswer.all of the following questions: If there are construction documents,.indicate where on the build4 g`plans the mandatory measures(sign lighting control)note block can be located: i §130.3(a)1-All indoor sigh lighting is controlled with an automatic time-switch control or astronomical time- Y N NA switch control. © Q f3l §130.3(a#2A. All outdoor sign lighting is controlled with a photocontrol in addition to an automatic time- Y N NA 2 switch control,or an astronomical tirrie=switch control. - _ 181 ❑ 13 EXCEPTiON to Section 130.3(a)2A:Outdoor signs in tunnels,and signs in large permanently covered outdoor Y NA areas that are intended to be continuously lit,24 hours per day and 365 days per year. ❑ 09 §130.3(a)2B. All outdoor sign lighting that is ON both day and.night is controlled with a dimmer that provides the ability to automatically reduce sign lighting power by a minimum of 65 percent during nighttime hours. Y N NA 3 signs that are illuminated at night and for more than 1 hour during daylight hours shall be considered ON both ❑ ❑ W day and night. EXCEPTION to Section 130.3(a)M.Outdoor signs in tunnels and targe covered areas that are intended to be Y NA illuminated both day and night. ❑ M §130.3(a)3. Demand Responsive Electronic Message Center Control.An Electronic Message Center(EMC) Y N N/A having a new connected lighting power load greater than 15 kW has a control Installed that is capable of ❑ ❑ Z 4 reducing the lighting power by a minimum of 30 percent when receiving a demand response signal. EXCEPTION to Section 13a3(a)3:Lighting for EMCs that is not permitted by a health or life safety statute, Y NA ordinance,or regulation to be reduced by 30 percent. ❑ IN Field Inspector Notes: 3 lune cA Building Energy Efriciency standards-2013 Nonresidential Compfiance 20#1 STATF,QF CALIFORNIA SIGN LIGHTING CEGNRCC LTS-O t-E Revised 06/13. CALIFORNIA ENERGY COMMISSiON CERTtFIC'ATE OF COMPLiANCE DATA FIELD DEFiNITtONS AND CALCULATIONS NRCC-LT"1-E sign Lighting (Pae 3 of 4)' Project Name: (Yate Prepared: 4.Maximum Allowed Lightlne Power Method of Compliance Certificate of Compliance and Meld inspection Energy Checklist Complete this part if there are signs using the maximum allowed lighting power method of compliance.(Complete part 5 of this Certificate of If there*are signs using the Speclf c:I1%.ting solutes method of comploncel A B C D E 5 !> l ! opnoNAL-Energy F€fied inspector SymbolComplies Or Code Description of the Sign Verified Labe1(see Allotted Watts Design watts YIN Check that sign i iWutdohs below) complies _ co 05 to w p gr an z .. h �f... 3_.: E3 13.. 13.13;. ' 0 0 EV E3 t3 13 > 13 El 13 0 D A Symbol or code usedon the plans(when plans are required)and other documents,, 8 A description of the sWt,or location of signon the building;and the toration o€signon constsuctim documents- OPTIONAL ocumentsOPTIONAL-Check this box only if this sign has a permanent,pre-printed,factory-installed,,ENi RGY VERIFIED label,confirming that the sign complies with the:Seetlnn W.8 of the California 2013 Title 24,.Part 6 Standards;using tate Maximurn Allowed Lighting.Power method of compliance. The only labels that will be recognized for this purpose are ENERGY VERIFIED Certification Marks authorized by Underwriters Laboratodq s t1)or other Product Certification Body accredited to ISO/JEC Guide 55 by the American National Standards Institute in accordance with iSOAEC 17011.Surveillance by the Accredited Certification Body shall be an ongoing annual inspection program carried out by a Type A inspection body in accordance with ISO/iEC 17020.For signs with such an ENERGY VERIFIED label, columns'D'through'.l',are not required to be fitted.out,Note:.Using an ENERGYVERiFIED label is an optional method to validate compliance.An ENERGY,VERIFIED label is not needed for compliance. D The sign area in square feet. E List"i"if the sign is infernal"ritum r ated..List;g"if the sign is externally illuminated. F Allowed watts per square foot. Enter 121f.the sign.1s fisted as."1"in cotumn E.Enter 2.3 if sign is listed as"E"in column I- G Multiply the square footage in column 0 times the aff6void.Lighting,Power Density(LPD=watts)In column F. H Show the total instailed,wattfli the.si n,-as determined according to thea linable provisions of§130(c). I Enter Y if the number in column H.Is less than orequal to the number in column G. Otherwise,the slgn does not comply. J This page doubles as a field inspection checklist. Field Inspector Notes: CA Building Energy Efficiency Standards-2013 Nonresidentiat Compliance June 2013 STATE Of CALIFORNIA SIGN LIGHTING , CEGNRC�trs o t e osrr3 CALIFORNIA irtMGY.Gt}M(yitSSIt3N ot CERTIFICATE OF COMPLIANCE—DATA FIELD DEFINITIONS AND CALCULATIONS NRCt L7�-01'-E Sigtr lighting' A.Page4 r)f 41; P N I1ate Prelwrkd: 5.Specific lifth#iria Source Method of Compliance ificate-of Ca pRanee and Field kispeakm Enew Checkft Corr€plete this part ifthereare signs using the Specific'lighting source:method of compliance. (Complete part 4 of this Certificate 0 Compliance if therm are signs using the roaxitnurn allowed fighting i rer; t d c*ffq3fiatrce) , t..li! _ - a OPTIONAL Specific light source used for Symbol ENERGY VERIFIED cpmpliax ce ��� or Description label Shall include only lighting Cede (see Instructions teeluriagies Inc€#e#ows below) List all that apply LED Letter Si __ 37 0 A Symbol or code used on the plans(when plans are required)and other documents.' 8 A narrative description of-the sign,oriocation of sign on the building;and the-locatioa_of sign on'bristrucdah documents _ C. OPTIONAL-Check this,box only if this sign,has a permanent,pre-printed,factory-installed ENERGY VERIFIED label,confirming that this sign complies with the Section 140.8 of the California 2033 Title 24,Part-6 Standards,using the Specific-Ligli Source Method of Compliance.The only labels-that'will be recognized for this purpose are ENERGY VERIFIED Certification Marks authorized by-underwriters Laboratories{UL)or other Product Certlfication Body accredited to ISO/IEC,Guide.55 by the American National Standards institute in accordance with ISOAEC 17011.Surveillance by the Accredited Certification Body shall bean ongoing annual inspection program carried out by Type A Inspection body in accordance with ISO/IEC 17020:For s#gris'with"such an ENERGY VERIFIED label,column 1Y is not required to be filled out.Note:Using an ENERGY VERIFIED label is an optional method to validate compliance.An ENERGY VERIFIED label is not.needed for.compliance. Specific Ugh t source Compliance Met#rl od. The signs}identified above use only the foitoanng#ighting technoiogies: List'all applicable numbers(1 through io):that apply in column D above far each row. -... I 'High*erri='si3d#iirsst. _. amps" Metal halide lamps;that are pulse start-or ceramic served by a ballast that has a mir imum..effciency of.88.percent or._ Z.- greater,Ballast,efficlency is,the;measured putput vrattage to thelamp d}vided by the measured operating input wattage when tested according to ANSI C82.6-2005.' > r. Metal halide;tarrrps that are pulse start that are.3,20watts or smaller.;artnpt 250 watt or17S wattiarnps:and.ace served by a ballast that has a ini6imum efficiency of 80 percent. Ballast efficiency is measured output wattage to the Iarrtp riivided the'm6asured vWatg input grattage when tested accoi`dli*to ,NSI C 2.6-2005. - Neori orcold cathode igmps vritEi transformer or power siepply preq xznefcercgreat 75# cent 4 when xhe transformer or power supp{y rated output current is less than 50 MA.The ratio of the output watmge to the'input wattage is at 1t10 ort iubiiag Toad. - k> - Neem or cir[d cathode lamps with transformer bt power supply efFuenzy eatertharr or eiluat#£r a iarmui in efflclency of 68 tiercent 5 when the traces€ormeror powers ly€ated�tput current is td iii d€ o waif a to wut wattge is at 100 percent tubing load. I uorescentiighting systems meeting one a#the following requirements A Use only Wraps vrt}t a rrii trrrt3rm Ior rendering index(tERi);IIf. SO,or-B.Use-"electronic ballasts with a fiunciameatai output.frequen not lessAan 20 kHx ..J -7. Light einiiting=diodes tel wrtF apower supply having'aiz ef#iciedc S#rtgle voltage external paver supplies that are desrgned to convert 12o volt AC input intolpwer voltage,OC or AC output,and have a 811 nameptate°outputpower less lanor equal"fcs 2tf wattsshaH ciirrrp{y witl%;tiri<applcatrle{ #ueisaenls of the l#pp#iarice ffflii±rcyr Regulations(Title 20)­1-1,1111 'Compact.fluoresceMlaqnps thatdo not ergtartr amediumscrew base sockets"!0* n E Thlspage'doubles as afield inspection checklist. ......... ... _ _. CA Building Energy Efficiency Standards-2013 Nonresidential Compliance � .- lune_2013 HS2 ACADEMY BUILDING SIGN ELEVATION: 10789-A S. BLANEY AVE. CITY OF CUPERTINO 12'-0" SIGN AT: 10789-A BOLLINGER RD. 5TORE FRONTAGE RACEWAY PAINTED TO �l Suild g®Rr,�� MATCH BUILDING COLOR dd �� De5395 CR055ROAD5 XECKED T PLA EwEp FpRCt7 By f eviewed 8y 5"THICK INDIVIDUAL CHAN Tr )f ERNALLY ILLUMINATED 3/4"BRONZE COLOR TRIM CAP, 11 NTL�eB�d`8LaPWNT DE PLANNING DEPT. LETTERS WILL BE RED COLO11PCc/�Q����p74 _ CUPERTINO 5CALE:1/4"= - T :5EP-19=20T4 ROVED BUILDING ELEVATION: ® �1� lob site during construchonCitliosnu awSulbo make ante _----- — changes or alterations on same, or to deviate HS2ACADEMY therefrom, without approul from the Buildin n{��,,� 10789-AS.BLANEY�IVE. roping of this p;an a d s ecifi�;,ri 95hliCtTIY WWALL CITY OF CUPERTIN�E held to ermit Or" F ons SHALL NOT a - al of a. � � of any provis tt��>GithruRNC ,,Yl �V►'tP.6" nY inance or State L � aw. P1N TTERS 10 as _l _ LA5TIC FACE 10 LOW VOLTAGE 01?1 #10x3"SCREW %'_ ♦ �� �"� TRANSFORMER MIN.3 PER LETTER DI5C0 T LED SHEET METAL RACEWAY � :i2i i 4. 1.5"x1.5"x1/5"x2" ANGLE IRON BRACKET . 1/4"x3"TOGGLE BOLT �F/C7 lzplb AT TOP&BOrTON Z®J� �Y MOUNTING DETAIL 1982 Stone Ave San Jose,Ca.95125 cnV All designs&art works belong to E-mail:allensigns@yahoo.com ff 40, 280 6 00 //'IR 40 5 28g=87 00 Allen Signs Inc any duplication is State Contractor License#834580 prohibited-----Copy right 2014