RM-2014-29b OFFICE OF COMMUNITY DEVELOPMENT CITY HALL 10300 TORRE AVENUE•CUPERTINO, CA 95014-3255 C U P E RT 1 N O (408)777-3308• FAX(408)777-3333•planninc�[a�cupertino.orcl December 10, 2014 Li Cui 1690 Lee Drive Mountain View, CA 94040 SUBJECT: MINOR RESIDENTIAL PERMIT ACTION LETTER—Application RM-2014-29: This letter confirms the decision of the Director of Community Development, given on December 10, 2014, approving a Minor Residential Permit to allow a first floor addition to encroach six (6) feet six (6) inches into the required twenty (20) foot rear yard setback, located at 866 Bette Avenue, with the following conditions: 1. APPROVED PROJECT This approval is based on plan set entitled "Li Cui, Address: 866 Bette Avenue, Cupertino CA 95014" consisting of five sheets labeled "A0.0-A0.4", dated "Received November 10, 2014" except as may be amended by conditions in this resolution. 2. RESTRICTION ON FUTURE EXTENSIONS OF LEGAL NON-CONFORMING WALL LINES. Per the R1 Ordinance,no future extensions of legal.non-conforming wall lines within the required side yard setbacks are permitted for the life of the house. The property owner shall record a covenant on this property to inform future property owners of the restriction against the future extension of non-conforming wall lines. The precise language will be subject to approval by the Director of Community Development. Proof of recordation must be submitted to the Community Development Department prior to final occupancy of the residence. 3. SIDE YARD SETBACK COVENANT The property owner shall record a covenant on this property to inform future property owners that the north side yard setback is the conforming setback and the south side is the nonconforming setback. Any future additions along the south side property line must be setback at least 10 feet from the south side property line (and/or subject to the discretionary approval of the City of Cupertino) in order to provide a combined side yard setback of 15 feet The precise language will be subject to approval by the Director of Community Development. Proof of recordation must be submitted to the Community Development Department prior to final occupancy of the residence. 4. ANNOTATION OF THE CONDITIONS OF APPROVAL The conditions of approval set forth shall be incorporated into and annotated on the building plans. Minor Residential Permit Action Letter Page 2 RM-2014-29 5. ACCURACY OF THE PROTECT PLANS The applicant/property owner is responsible to verify all pertinent property data including but not limited to property boundary locations, building setbacks, property size, building square footage, any relevant easements and/or construction records. Any misrepresentation of any property data may invalidate this approval and may require additional review. 6. CONSULTATION WITH OTHER DEPARTMENTS The applicant is responsible to consult with other departments and/or agencies with regard to the proposed project for additional conditions and requirements. Any misrepresentation of any submitted data may invalidate an approval by the Community Development Department. 7. EXTERIOR BUILDING MATERIALS/TREATMENTS Final building exterior treatment plan (including but not limited to details on exterior color, material, architectural treatments and/or embellishments) shall be reviewed and approved by the Director of Community Development prior to issuance of building permits. The final building exterior plan shall closely resemble the details shown on the original approved plans. Any exterior changes determined to be substantial by the Director of Community Development shall require a minor modification approval with neighborhood input. 8. INDEMNIFICATION To the extent permitted by law, the Applicant shall indemnify and hold harmless the City, its City Council, its officers, employees and agents (the "indemnified parties") from and against any claim, action, or proceeding brought by a third party against the indemnified parties and the applicant to attack, set aside, or void this ordinance or any permit or approval authorized hereby for the project, including (without limitation) reimbursing the City its actual attorneys' fees and costs incurred in defense of the litigation. 'The City may, in its sole discretion, elect to defend any such action with attorneys of its choice. 9. NOTICE OF FEES, DEDICATIONS, RESERVATIONS OR OTHER EXACTIONS The Conditions of Project Approval set forth herein may include certain fees, dedication requirements, reservation requirements, and other exactions. Pursuant to Government Code Section 66020(d) (1), these Conditions constitute written notice of a statement of the amount of such fees, and a description of the dedications, reservations, and other exactions. You are hereby further notified that the 90-day approval period in which you may protest these fees, dedications, reservations, and other exactions, pursuant to Government Code Section 66020(a), has begun. If you fail to file a protest within this 90-day period complying with all of the requirements of Section 66020, you will be legally barred from later challenging such exactions. Please note that if this permit is not vested within a year, it shall expire on December 10, 2015. Staff has made all the findings that are required for approval a Minor Residential Permit as required by the of Cupertino's Municipal Code, Chapter 19.28.140 (A). 1. The project is consistent with the Cupertino General Plan, an�applicable specific plans, zoning ordinances and the purposes of this title. � Minor Residential Permit Action Letter Page 3 RM-2014-29 The proposed project is consistent with the General Plan as the project is within the Low Density land use area. There are no applicable specific plans that affect the project. The project has been found to be consistent with the requirements of Cupertino Municipal Code Chapter 19.28 Single Family(R-1) Residential. 2. The granting of the permit will not result in a condition that is detrimental or injurious to property improvements in the vicinity, and will not be detrimental to the public health, safety or welfare. The granting of the permit will not result in a condition that is detrimental or injurious to property improvements in the vicinity, and will not be detrimental to the public health, safety or welfare as the projects is located within the R1-6 (Single Family Residential) zoning district, and will be compatible with the surrounding uses and neighborhood. 3. The proposed project is harmonious in scale and design with the general neighborhood. The proposed project is located in a residential area consisting of single family homes. The proposed project maintains the single-story scale found throughout the neighborhood. 4. Adverse visual impacts on adjoining properties have been reasonably mitigated. Any potential adverse impacts on adjoining properties have been reasonably mitigated through the maintenance of a six (6) foot high fence surrounding the rear portion of the property. Additionally, all adjacent property owners were notified of the project with no comments submitted in regards to the project. Also, please note that an appeal of this decision can be made within 14 calendar days from the date of this letter. If this happens, you will be notified of a public hearing, which will be scheduled before the Planning Commission. Since y, Erick Serrano Assistant Planner City of Cupertino ericks@cupertino.or� Enclosures: Approved Plan Set G:\Planning\MinorResidentinl\RM,R£�RMApprovals\2014\RM-2014-29Actionletter.doc GENERALNOTES IT IS THE RESPONSIBILITY OF THE CONTRACTOR AND SUBCONTRACTORS TO CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS INDICATED ON THESE DRAWINGS AND MAKE KNOWN ANY DISCREPANCIES PRIOR TO COMMENCING THEIR WORK THESE DRAWINGS P,REA INTENDED FOR USE IN A NEGOTIATED CONSTRUCTION CONTRACT AND,THEREFORE,MAY NOT SPECIFICALLY DETAIL OR SPECIFY MATERIAL AND/OR MANUFACTURERS THE CONTRACTOR SHALL PROVIDE ALL SAMPLES AND OR CUTS AS REQUIRED TO ASSIST OWNER OR HIS AGENT IN MAKING MATERIAL SELECTIONS.FOR THE PURPOSE OF ESTIMATING,THE CONTRACTORS SHALL USE THE MATERIALS SELECTED BY THE OWNER,OR IN ABSENCE OF SAME,HE SHALL PROVIDE AN ALLOWANCE AMOUNT AND SO CONDITION ANY COST ESTIMATE..ALL MATERIALS SPECIFIED IN THESE DRAWINGS SHALL BE INCLUDED IN SUCH ESTIMATE NO GUARANTEE OF QUALITY OF CONSTRUCTION IS IMP�IED OR INTENDED BY THE ARCHITECTURAL DOCUMENTS,AND THE CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR ANY OR ALL CONSTRUCTION DEFICIENGES. THE GENERAL CONTRACTOR SHALL HOLD HARMLESS,INDEMNIFY AND DEFEND THE DESIGNER FROM ANY ACTION INITIATED BY THE INITIAL OWNER OR ANY SUBSEQUENT OWNERS FOR CONSTRUCTION DEFICIENCIES,MODIFICATIONS OR SUCH CONDITIONS WHICH MAY BE BEYOND THE CONTROL OF THE DESIGNER. ALL WORK SHALL COMPLY WITH APPLICABLE CODES AND TRADE STANDARDS WHICH GOVERN EACH PHASE OF WORK,INCLUDING BUT NOT LIMITED TO:UNIFORM BUILDING CODE(UBC),UNIFORM MECHANICAL CODE(UMC),NATIONAL ELECTRICA�CODE(NEC),NATIONAL PLUMBING CODE(NPC),AND ALL APPLICABLE LOCAL CODES AND LEGISLATION. THE CONTRACTOR SHALL REVIEW AND RECORD THE CONDITIONS OF ALL EXISTING SITE IMPROVEMENTS INCLUDING PAVED AREAS.HE SHALL MAKE KNOWN ALL EXISTING DAMAGED OR DISREPAIRED ITEMS AND CONDITIONS THAT MAY WORSEN DUE TO THE CONSTRUCTION.ALL ITEMS IN GOOD CONDITION SHALL BE MAINTAIN IN THEIR PRESENT CONDITION AND ANY REPAIR OR DAMAGE WHICH OCCURS DURING CONSTRUCTION SHALL BE TFiE RESPONSIBILITY OF THE CONTRACTOR. CONTRACTOR SHALL THOROUGHLY EXAMINE THE SITE AND SATISFY HIMSELF AS OF THE CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED.THE CONTRACTOR SHALL VERIFY AT THE SITE ALL MEASUREMENTS AFFECTING HIS WORK AND SHALL BE RESPONSIBLE FOR THE CORRECTNESS OF SAME.NO EXTRA COMPENSATION WILL BE ALLOWED TO THE CONTRACTOR FOR THE EXPENSES DUE TO HIS NEGLECT TO EXAMINE OR FAILURE TO DISCOVER CONDITIONS WHICH MAY AFFECT HIS WORK. ALL NEW INTERIOR PAINT COLOR,FLOOR,WALLS AND CEILING FINISHES SHALL BE SELECTED BY OWNER AT THE TIME WHEN IT IS NECESSARY FOR THE COMPLETION OF THE PROJECT. ALL PUBLIC IMPROVEMENTS SHALL BE MADE IN ACCORDANCE WITH THE LATEST ADOPTED CITY STANDARDS.THE STORING OF GOODS AND MATERIALS ON SIDEWALK AND/OR STREET WALL NOT BE ALLOWED UNLESS THE CONTRACTOR HAS APPLIED AND SECURED A SPECIAL PERMIT WHICH ALLOW SUCH STORAGE TO BE PLACED. THE PROPERTY OWNER SHALL RECORD A COVENANT ON THE PROPERTY FOR THE NEW TREES/SHRUBS PLANTED FOR PURPOSE OF REQUIRED REPLACEMENT TREES,PRIVACY PROTECTION,AND REQUIRED FRONT YARD TREE. _ � PROJECT DESCRIPTION: ONE STORY SINGLE FAMILY HOME FRONT AND REAR YARD BUILDING AODITION OF 595 SF. ��� �t�, SITE PLAN LEGEND: �� P.U.E EASEMENT �� W.C.E EASEMENT � PROPOSED REAR YARD I 1 PROPOSED BUILDING ADDITION DRAINAGE DIRECTION MIN SLOPE 2%(IMPERVIOUS) AND 5%(LANDSCAPE)AWAY FROM BUILIDNG _ �EXISTING 6 HIGH FENCE TO REMAIN O ~ Z PROPERTYUNE SETBACKLINE Z II �PROPERTY LINE , --�-------------------------.-------.----- i � �----�------------------------------ : � �--I------------------------------------J I � � � I I (E)ELEC PANEL TO _'_•�'_'�'_'_•�'_'_'_--'_'—'_' —' REMAIN I � I � � � �------- ---- �� I � — -------- I i � � � � I (E)AC UNIT TO iI � REMAIN i i ' � i � � I � —— J � � +i-9�_z� I ��, (E BUILDING SETBA K o i i g � � I I � ', j I I � I � � � , � � i i ( � � -�---f- -------•---- � � � � . G, . � a S�C� � � � I � � -�---�- •---•-�---- EXISTING SITE 1/8"=1'-0" MULBERRY 19"DIA TO B i REMOVE � � '_-----------------�---- � � � I � ----•-------•—•---•I•---' I �,_a. BETTE AVE NOTE: t.PROVIDE POSITIVE DRAINAGE TO ROOF DRAINS FROM ALL PARTS OF THE ROOF. 2.D.S.o—� INDICATES 2'x3"26 GA.G.I. DOWNSPOUTS W SPLASH BOX LOCATED AS SHOWN. 3.PROVIDES 5"-26 GA.G.I OGEE GUTTER OVER 2x8 SPRUCE FASCIA BLARD- TYP. 4.ROOF PITCH TO MATCH EXISTING ROOF TYP.- U.N.O. 5.ROOF MATERIAL To MATCH EXISTING ROOF OVER 30p FELT-TYP. 6.PROVIDE NECESSARY FLASHING AT ALL ROOF AND WALL CONNECTIONS AS RE�UIRED. 7.PROVIDE 3/4"THICK T&G PLANKS(i�ROOF OVERHANG AREA. � o � N + � W a a m m i----------.___._.----� --- --- - --------� � -� �,, - - - -�-,�. - �.,�� .- �.��:� _ �:ti T_ �,..- _ .�' _ �-�� -- �-- =�-1 � �. I I �. �,`(E)EIEC'PANEL TO � ;, RE N I L1_.�ssz.-- --.�s�--- .,_. �: _ � TO MATCH TO MATCH l � I I EXISTING EXISTING �' S ^� 'DS � i i — , � _; �1� I i pS i — — ----� fi— �— � , � i � i', '� I I I� (�)AC UNIT I i � �Ri MAIN � i i i� i , i ! i� i I ' +/_9}�(E)BUILDING SEjBACK � � � � I �+i-s�� EAVE SET BA TO M � ( � � � � i i i i ( DS � r'-f � � � � ' s-o° ' 0 SETBAC N I I � � � � L._ I I � I � � DS I � � � I � .i-s,_�„ i EXISTING EAVE SETBACK i � ' +/-5:12 I +/-5:12 i I TO MATCH i TO MATCH � � EXISTING � EXISTIN= \ � � �`, I �----- - 1 ------- ----- 7 � � — ----------- - — ---- ---�-- �5----' � � � I io,_a, � ( )WALKW PRO SED BUILDING SE BACK (E)DRIVEWAY ( � ' I I � I ( � -�- ---•-----•-•-�-�-----•-----.-._�---•-•a1 2 PROPOSED SITE PLAN _ 1/8"=1'_0" PROJECT INFORMATION PROPERTY: 866 BETTE AVE, CUPERTINO,CA95014 APN: 36&24-047 OWNER: LI CUI LOT SIZE: 6,000 SF LOT ZONING: R-1-6 TYPE OF CONSTRUCTION:TYPE V-B OCCUPANCY: R-3 EXISTING BUILDING AREA: 1,080 SF. EXISTING GARAGE AREA: 468 SF. (FUTURE GARAGE RESERVE AREA:27.3 SF) PROPOSED ADDITION AREA: 943 SF. (INCLUDES FUTURE GARAGE RESERVE AREA:27.3 SF) LOT COVERAGE: 2,491 SF/6,000 SF=41.3%.(WO EAVE,PORCH,ETC) 2,920 SF/6,000 SF=48.6%(W/EAVE,PORCH,ETC) PROPOSED FRONT YARD AREA: 1,200 SF IMPERVIOUS AREA IN FRONT YARD AREA:570SF<50%*1,200 SF PROPOSED REAR YARD AREA:1,204 SF>FRONT60'x20'=1,200SF �. : � .��� VICINITY MAP - SITE ._����►}� f!� ��l .���.���0��: � ���gnat� �,;i ��. APPLICABLE CODES � � � 2013 CALIFORNIA RESIDENTIAL CODE 3 2013 CALIFORNIA BUILDING CODE 3 2013 CALIFORNIA ELECTRIC CODE3 2013 CALIFORNIA MECHANICAL CODE3 2013 CALIFORNIA PLUMBING CODE 3 2013 CALIFORNIA ENERGY CODE 3 2013 CALIFORNIA GREEN BUILDING STANDARDS CODE SYMBOLS 1 A ORIDETTER UMBER GRID LINE � DETAILNUMBER DETAIL -501 SHEET WHERE DETAIL IS DRAWN.SAME DISCIPLINE SECTION NUMBER SECTION A-301 SHEET WHERE SECTION IS §AFtE-6($LT�CTR� F H 4 INSULTION WALL TYPE STUD SIZE WALL TYPE WALL EXTENT Q DELTA DRAWING 1 SEE DESCRIPTION BLOCK REVISION ON SAME SHEET FOR DATE 8 DESCRIPTION O KEYED NOTES SEE DESCRIPTION KEYNOTE LIST ON SAME SHEET o�`�`� � FILLED LINE INDICATES PLAN NORTH NORTH DASHED ARROW ARROW INDICATES TRUE NORTH �,_a, BETTEAVE DRAWING INDEX A0.0 SITE PIAN A0.1{1 DEMOUTION PLAN A0.2 PROPOSED FLOOR PLAN A0.3 BUILDING ELEVATIONS A0.4 BUILDING SECTIONS LI CUI (OWNER) Address: 866 BETTE AVE, CUPERTINO, CA95014 Email: Li_cui68@yahoo.com .i�z--����%�.� Nov 1 o zo�4 ��: ,� , �f, ' �..�._.�..��f_��i`-� , w,,. -:� � DCEY PtAN i - ... � ,�- �... ._. _-.�...,_.. os. . - . � .. , ......,. _.._._ --+'�r....:y�.ac.�.-...�.�.�,...-.,�/:...<<_�..«.,.....�..-...........r.y.r PLANNING SUBMITTAL REVISION 11.05.2014 PLANNING SUBMITTAL 10.15.2014 NO. DESCRIPTION DATE CLIENT Owner PROJECT CUI RESIDENCE ADDRESS Enter address here PROJECT NO. project Number SCALE ��g��=1'-0" TITLE SITE PLAN • / ' 2013 0 �________________ -----------� }r-- __,�-. --,; ---- �--�--------- � �' ii �i u ii u ii � �i ii �i ii �i u ii w ii ii ii �L--�I �----------, �-n I r--,I � IIII I� � IIII I� --� `L---J r-�� i��r �' \ / � I! \ / I' li �� II _�U� r=� �-�---1--�--------------� r; _ . _ _ _ . , �. . .. . .�. .. �..s.. _.. �� �� — �� �� � � �� f �� i () � �� �� � �� U . -�.'_�.._..,Y. LEGEND EXISTING WALLS TO REMAIN. --=EXISTING WALLS TO REMOVE. DEMOLITION PLAN ,ia„_,,_o„ �"�. ����i��i��`��.�_�,..�m � �� a����rati�� �'�—,�f��� �..x�.,�,.�.�+ �ppr�val D�t� 7 ;��=i�--��,,.a.�....� �i�naturE ,�s:;= .- ; , , .,...,...�_--�--.� (�ase Managerl �' -� �� LI CUI (OWNER) Address: 866 BETTE AVE, CUPERTINO, CA95014 Email: Li_cui68@yahoo.com KEY PLAN PLANNING SUBMITTAL REVISION 11.05.2014 PLANNING SUBMITTAL 10.15.2014 NO. DESCRIPTION DATE CLIENT Owner PROJECT CUI RESIDENCE ADDRESS Enter address here PROJECT NO. project Number SCALE AS SHOWN TITLE DEMOLITION PLAN � � � 2o�s cQ LEGEND EXISTING WALL TO REMAIN AND REPAIR AS REQUIRED. �r 2x4 or 2x6 WOOD STUDS�16"O.C.W/ 1/2"THK.GYP.BD.ON BOTH SIDES USE W/R GREEN GYP.BD.�WET WALLS(1/2"CDX PLYVNOOD O/STUD �SHEAR WALLS).ADD SOUND BATT INSULATION. �2x4 OR 2�VNOOD STUDS�16" O.C.W/1/2"THK.GYP.BD. INTERIOR SIDE 7/S"CEMENT PLASTER OVER PAPER BACKED LATH OR WOOD SIDING OVER 15#BLDG.PAPER(PAINTED) OVER 1/2"CDX PLYVNOOD. (SEE ELEVATIONS FOR EXTERIOR FINISH) i �`,�''��f f •.,gr�. j# �i.��.��i�e'�,�it�d' ,�. 1� ° _ ,� ...r��r%,c���z.�r= '�,�� ;��plicati �.� ��.��?�!„�.� II,� �1�Y C.�t ��3 t _...�����_:, �T �, •' , �. �i�na�ure � ...r� "=. I;Ca�e Manager? .M� I NOTE: 'ALL ESCAPE OR RESCUE WINDOWS SHALL HAVE A MINIMUM NET CLEAR OPENABLE AREA OF 5.7 SQUARE FEET.THE MINIMUM NET CLEAR OPENABLE HEIGHT DIMENSION SHALL BE 24". THE MINIMUM NET CLEAR OPENABLE WIDTH DIMENSION SHALL BE 20". WHEN WINDOWS ARE PROVIDED AS A MEANS OF ESCAPE OR RESCUE,THEY SHALL HAVE A FINISHED SILL HEIGHT NOT MORE THAN 44" ABOVE F�OOR. 'TYPICAL ALL PLUMBING WALL BEARING WALLS AND WALL EXCEED 10'-0"HIGH SHALL BE 2x6 STUDS�16"O.C. 'TYPICAL ALL WATER SUPPLY PIPE TO BE COPPER. 'ADD SOUND BATT INSULATION IN ALL NEW WALLS. FIOOR PLAN NOTES: 1.PROVIDE 3'x3'MIN CONC.LANDING AT ALL NEW EXTERIOR DOOR,8'MAX.FROM FINISHED FLOOR. 2.TOILET ACCESS AREA SHALL BE 24"(D)x30"(V1n 3.SHOWER PAN SIZE PER OWNER WlfILE TO 72" U.N.O.PROVIDE SOAP DISH. 4.ALL PLUMBING FIXTURES SHALL BE OF UPC APPROVED PRODUCTS.THE FIXTURE IN SHOWER SHALL HAVE PRESSURE OR THERMOSTATIC MIXING VALVE THAT LIMIT WATER TEMPERATURE TO 120 F. 5.PROVIDE"DUROCK"OR"WONDER BOARD" WALL LINING AROUND SHOWER/BATHTUB AREA. CULTURE MARBLE OR TILE FINISH. 6.SHOWER CURTAIN ROD. 7.IC60#ER-5965,2'-0"'x3'-6"'SKYLIGHT,TYP. 8.NEW ACCESS TO CRAWL SPACE. 9.SUN TUNNEL SIZE PER OWNER GENERAL PLAN NOTES: 1.ALL INTERIOR DOORS TO BE HOLLOW CORE 1 3/8"THK.U.N.O.(SEE PLAN FOR SIZE) 2.ALL HOUSE TO GARAGE DOORS TO BE SOLID CORE 1 3/8"THK.SELF CLOSING AND TIGHT FITTING.(SEE PLAN FOR S�ZE) 3.ALL ENTRY DOORS TO BE SOLID CORE 1 3/4" THK. (SEE PLAN FOR SIZE) 4.PROVIDE A LANDING WITH A MIN.DEPTH OF 36" AT THE EXIT DOOR PER UBC 1004.9 5.WINDOWS AND GLAZED DOORS MUST HAVE LABELS FOR THE"U"AND"SHGC"FACTORS THAT ARE REQUIRED BY THE ENERGY DOCUMENTATION. NOTE: 'PROVIDE W/R GREEN GYP.BD @ AROUND SHOWER,TUBS PER SEC.2512 UBC. 'ALL BATHROOM LIGHTS SHALL BE FLUORECENT LIGHTS. 'ALL SHOWER OR TUB GLASS DOOR SHALL BE TEMPERED GLASS. 'PROVIDE A MIN.5 SQ.FT.MECHANICAL VENTILATING SYSTEM FOR BATH,UTILITY ROOM,AND ROOM OF SIMILAR NATURE. 'THE SHOWERS AND TUB/SHOWER WALLS SHALL HAVE A MOISTURE RESISTANT UNDERLAYMENT TO A MIN.HEIGHT OF 70"ABOVE THE DRAIN INLET PER SEC.807.1.3 OF 2010 CBC, 'PROVIDE SOUND BATT INSULATION BETWEEN ALL BEDROOMS AND BATHS. 'PROVIDE 12"MINIMUM CLEARANCE IN FRONT OF 2"OR LESS UNDER-FLOOR CLEANOUT PIPING AND 13"IF MORE THAN 2" DIAMETER PIPE.J 'NO UNDER-FLOOR CLEANOUT SHALL BE LOCATED MORE THAN 20 FEET FROM CRAWL HOLE ACCESS PANEL.(CPC 707.10) 'OUTDOOR A/C SUCTION LINE INSULATION EXPOSED TO WEATHER SHALL BE PROTECTED FHOM UN DETERIORATION OR PHYSICAL DAMAGE.(GEES 150Q)2 150(m)9, 'THE"F.A.U."WHICH LOCATED IN THE ATTIC NEED TO BE WITHIN 20'FROM THE ACCESS AND HAS A CONTINUOUS SOLID WALKWAY AT 24"WIDE.PROVIDE A SWITCH-CONTROLLED LIGHT PER CMC 908.0, •ENVIRONMENTAL AIR DUCTS SUCH AS VENTILATION FOR HUMAN USAGE,KITCHEN RANGE EXHAUST.BATHROOM EXHAUST,AND CLOTHES DRYER EXHAUST SHALL BE EQUIPPED WITH BACK-DRAFT DAMPER PER CMC 504.1. "A DEDICATED 2QAMP CIRCUIT SHALL BE PROVIDED TO SERVE THE REQUIRED BATHROOM OUTLETS.THIS CIRCUIT CANNOT SUPPLY ANY OTHER RECEPTACLES LIGHT/FAN PER CEC210.11(C)(3). 'LIGHT FIXTURES IN TUB OR SHOWER ENCLOSURES ARE LAGELED'SUITABLE_FOR DAMP LOCATIONS"PER CEC 410-4(a). •ALL RECESSED LIGHT FIXTURES SHALL BF IC RATED OR FIXTURES NOT IDENTIFIED FOR CONTACT WI INSULATION SHALL HAVE ALL RECESS PARTS SPACED AT FAST 1/2"FROM COMBUSTIBLE MATERIAL AND 3"FROM THERMAL INSULATION PER CEC 41a66. 'BATHROOM SHALL BE HIGH EFFICACY LUMINAIRES OR CONTROLLED BY AN OCCUPANT SENSOR THAT DOES NOT TURN ON AUTOMATICALLY OR HAVE AN ALWAYS ON OPTION. 'ALL OTHER INTERIOR ROOM EXCEPT CLOSETS LESS THAN 70 S.F.SHALL BE HIGH EFFICACY LUMINAIRES OR CONTROLLED BY A MANUAL ON OCCUPANT SENSOR OR DIMMER, 'ALL OUTDOOR DOOR LIG!ITING THAT IS MOUNTED TO THE BUILDING SHALL BE HIGH EFFICACY LUMINAIRES OR CONTROLLED BY PHOTO.CONTROU MOTION SENSOR COMBINATION. 'VENTIL ATION IN THE BATHROOM SHALL PROVIDE 5 AIR CHANGES PER HOUR AND BE CONNECTED TO THE OUTSIDE AS PER CBC 1203.3. io < �� b �� O m \� � � ( � h i � . i b R. 9 �I no.a �___ __ __ _ � ' , i A0.4 A0.3 2 � (f�UTILITY CL05�T (E)LAUNDRY � DINNING RO __ ,_—v--.�:_ 2 PROPOSED FLOOR PLAN 1/4"=1'-0" 0 � �,_5. -�_ .: � --- . _ (E)SUDING DOOR SLIDING DOOR (E)AC UNIT TO REMAIN �� LI CUI (OWNER) Address: 866 BETTE AVE, CUPERTINO, CA95014 Email: Li cui68@yahoo.com KEY PLAN PLANNING SUBMITTAL REVISION 11.05.2014 PLANNING SUBMITTAL 10.15.2014 NO. DESCRIPTION DATE CLIENT Owner PROJECT CUI RESIDENCE ADDRESS Enter address here PROJECT NO. pro�ect Number SCALE As indicated TITLE PROPOSED FLOOR PLAN � ' 2013 CQ ��i ��������t�i 1 ----�--.____.-°_ .i��������1Q�i ��'��'�� -����� �a�j� � � -� ������i�1� ���, __��� e.�.�„_.»r__..,�.,....�.,. '�'�.'�, ... �^�ij.�;F•�vt�`�'`.;',.'. ELEVATION NOTES: 1.NEW ROOF MATERIAL TO MATCH EXISTING. 7.DECORATIVE 14"x18"GABLE VENT W 4"TRIM. 2.WOOD SIDING FINISH,COLOR TO MATCH EXISTING. 8.EXISTING ROOF TO REMAIN. 3.WOOD TRIM @ EAVE W!GUTTER. 9.STONE OR SLATE VENEER OPTIONAL PER OWNER. 4.4"WOOD TRIM @ WINDOW SILL. 10.WEEP SCREED.A MIN OF 26 GA.CORROSION-RESISTANT WEEP SCREED W/A MIN VERTICAL ATTACHMENT FLAGE 5.4"WOOD TRIM AROUND WINDOW/DOOR. OF FOUNDATION PLATE LINE ON ALL EXTERIOR STUD WALLS W/STUCCO.THE SCREED SHALL BE PLACED A MIN OF 4" 6.145.5"x5.5"UNDER FLOOR VENT ABOVE THE EARTH OR 2"ABOCE PAVED AREAS AND SHA�L BE OF A TYPE WHICH WILL ALLOW TRAPPED WATER To DRAIN TO THE EXTERIOR OF THE BUILDING. PROPERTY LINE ---� I I e �'�� , ' I I , ` �I I ' , , L i I m �� � i' ➢ o k'--c ----- �. h m �� � � I , � NOTE: j �� J� �'r , ANY CHANGES TO THE APPROVED I I : ,>�L_JI�JL��I� COLORS,MATERIALS,AND EXTERIOR � � ������_ FINISHES SHALL BE REVIEWED AND , ,� APPROVED BY THE CITY OF CUPERTINO I i O � � � PLANNING DIVISION PRIOR TO I NSTALLATION/APPLICATION. I- 5._�, CONFORMING SET6 CK �PROPOSED EAST ELEVATION _,___________ ___ �3/16"_�'-0" -. _.--- Q � � r n � v � PROPERTY LINE� i � \ � � , , , , , , , „ O � \\ �' � I z g 2�� N ���. � I W S � � I � 4 o I b ( Q �' � � s o I - — — I _ � � ', �o �c �o�-a� �, SET BACK ---�N�T.O.P--- / _ m � °> II � - ------- �PROPOSED WEST ELEVATION ` 3/16"=1'-0" � 'v o � m � N. n �. io n o ° m ------- ---�— 0 0 0 � o 0 0 0 0 0 �PROPOSED NORTH E�EVATION �' 3/16"=1'-0" � � N�T_O F �li � �� o °' m ---- -------�---�--C----C. ----,—�----�, ----�-------------- i� � --- .—�-----C, — 4 PROPOSED S( �- 3/16"=1'-0" LI CUI (OWNER) Address: 866 BETTE AVE, CUPERTINO, CA95014 Email: Li_cui68@yahoo.com KEY PLAN PLANNING SUBMITTAL REVISION 11.05.2014 PLANNING SUBMITTAL 10.15.2014 NO. DESCRIPTION DATE CLIENT Owner PROJECT CUI RESIDENCE ADDRESS Enter address here PROJECT NO project Number SCALE 3/16"=1'-0" TITLE BUILDING ELEVATIONS �, � t 2013 CD I i8J 16d / i ��, RAFTER TIE SIMPE,ON"Ulb" I-IAN!sER.tTP. ��t7 P.MStA14 �,, ,� •as�o�. :;�'�; � RCCf PLr.,.00D ; �R r�.aN � � R�+FTER JO ST `�� PER PLAN , �� `� \ /B 6d �� h�� �� I .'\ ��. \� •'\�� '��. ,�. 2x6 Rt+fi�R TI£•�Fe'C.G. .''.514 r—R^•�dF PLT�.,00[: 435 s �\ Pif PLAM � II"OL �\ ,Y / I �I �/',, r �J 1,� / \ —Fu - 2x S1UD UidLL � •16"C:. � 695 L , �—�6d+3'^C. � �7 ` —EN. if�� EN. � P92 f'I..dN7 �i■� �O n BUILDING LONGITUDE SECTION � � 1/4"=1'-0" ��2"PL7�..00G:GCic JR CSB: t..i'2d•6"O.C.EGG� 15:16d�6TTAGHED 2"CC F ELC � GPILiVG JCISTB �� tG RAFtER JCISt� \ Ie00F ECG�NGIL'NCs _ ' ,�i :x BLJGKiNG � � /�� ; ' ,�yi _,\ , , r SEE ARGF1 D.JGS �� !"� �—� �JR RCOF SLOF� ; t�+ + � :�� + ;^r� + ; SiMP50N HI IP—'� / •EAGH R R JGIS�,� � `, ' RAFTER JOISTS I°�R PLAN / `' � ��/ �\��' C�IL7JG JOISTS PER PL•+N � I M �A35 CLIP�24"JC fDCsE NA LNG �1 ' \ � !36�Ibd�EAGH SIDE � W�1ERE TOP PIsATE SPL CE, LAP 60"C.G.71"P-U.ON CH.-B.AD. \ � F�ADER PER PLAN �,kt£RE CG.r.JRS �RQ�a`J v�J'-�-' I t�F{ERE OCGURS � FOR FI�PROFFII�Ks -5l�D. 57lIDU.ALL-SAI3. '�� � SHEAR TRANSFER ��� 6 SHEAR TRANSFER�a EAVE �° 2 ROOF SNE.Of1�lr►.� 2x BLfGG•BRGGES PER PLAN \� gd o 4"D.G. 8d`b"OG� �'\ * \ \ \ �r r� r;`� � I�ADER;MC9T �\ _ 1 . F- % GCf1MONLT"Cs4RAGE% � J J ------ %/ � `� _ ; � � � --�,e�"PL.�.C���L.'8d•b"DG � �� f�" ��E 3iJPP�R?EP�PI.� � z � _- �'-e'M'N.PaNEL LENGiH tL� q ����C�1 � ' 0 / �DBL JOf57:3R BLK'� � iTP-��10LC-DC4N 0 //- i' _ QEp(-�D�qO�pUyM�p�7�BJILDMG OFF C�4L.IE00'C..dd°AG 7Y v£D ___ - !��n ar�c�ac�rs u� - XS'X3;'6"�R r ' l5EC.180Fab' �' �Caror�;oNtinwous foR 16d•b" PER'SW' LB�L'iTF�I OFg�,a�D Jl4LL LI1� ST,JCU.ALL-SAD.�, " \�--- u��oNE�IQEB.aR coNlhJ.k:+JS � toP a�earr� �o�e��r��eoof,r.� \ � -SAD. ALTERNATIVE BRACING WALL ��2�� 7 GABLE END BRACE X � a _ � DBL�OISf EaCN S�DE oF or-�N rKr OPENING�a ROOF/ FLOOR bd�6„�� , RO�?RJSS—-�- 'R.4F�ER SIH� �2X6 CIAGJIVGL BRGCiNW•6'-0�� �/'A3S'GL'P PER BRGGE k� � ?x4 GONT. A35 CL'P•14"C!'. CEILING JCISTS--� � �• � 3 2x Ra�7�le;w � '435'U.'P E6 Slp� j� TC ix C.ONT.SLEEPER / �Ro'�5►�4T1�I�NG i' Q'�. � EDGE Nl�iLMG �—ix SLE�pER u,�' C 3;'bd/?RU55 RL�FTER% 34' I 8 I CALIFORNIA VALLEY FRAMING I �' I 4 �,_ �.'r-r..-�� (E)GA T�'=' C�16 ::TF.A� C��iTi��U'��� AL'J�.G THE 'P;H�JLE LEh:�TH (?F THE E,.TI=E _H:,E�_w�LL AEOVE TYPICAL 24 GA.GALV.SHEET METAL GUTER AND DOWN SPOUT. TYPICAL 2x8 REDWOOD FASCIA BD. TYP.REPLACE THE(E) ROOFING TO COMPOSITION SHINGLE W/#306LDG.PAPER O/ PLYWOOD SHEATHING OI ROOF FRAMING i i bl c� � �'� � n BUILDING LATITUDE SECTION 1/4"=1'-0" rc�� �-�aTE .J'JFLE 7= 3x �Sl.c^Kiv., rT�r. ? 1 i1.i EA ..:I i)E HEAC>E�i ftl''LE STUi�`: ��(j � �7� _...,. STA�;ERED ?x4 :TUC` `� ,J .J.�. �'U�^H SILL v4'HERE :��C'..<�; P✓4XI�,�U�� HEA�EI� �Na. r.c��i���a� o�E.ir c .,�Er�i��c. �'IZE 'FE?,ING, �,N-':N-FE�?�INGI 1 x 4 3' 0" 3-6'� � x -, �.'_G" 5. ,,,, _ -� '� � n ?� �- ,� x � r:'-' i �' � K �� � �� �.,. t��A:�11a�1�1 ��:%U:,H `>ILL ���AN r.�;'�flv�.L. ��=�E'�,!^,�-. �IZE .� x 4 - �l x 1 1-- iUB DIAPHRAGM 1/2"=1'-0" iTT')V1 F L�TE �� ��..n+����������'� 1-,C;LE ix ,'.T ,:.. .: �' ....�.,a�:.a+*�.s-���«. .v...r I,�c. ,� iI^r� n LE (.?I-FLE., t�'"�! °��1�,i'IIL+tUt�t1�!_ �.,,��1�,�������:�,�1G.. >TU��`; qT 4 ,� �.. 3 � s .-.� ,� -, Y ,� HE� E_� ���C���I ���� . � ..,r_ � ��� I ;x HEN �E�%�, �t =;ILL,, ,. � T T�� :�,���� �ig����,r� . - � , ;t��.�?�fana�n -.Tt,���_ � � / LI CUI (OWNER) Address: 866 BETTE AVE, CUPERTINO, CA95014 Email: Li cui68@yahoo.com KEY PLAN PLANNING SUBMITTAL REVISION 11.05.2014 PLANNING SUBMITTAL 10.15.2014 NO. DESCRIPTION DATE CLIENT Owner PROJECT CUI RESIDENCE ADDRESS Enter address here PROJECT NO. p�.pj�Number SCALE AS SHOWN TITLE BUILDING SECTIONS � ' / 2013 cQ