R-2014-38b .
OFFICE OF COMMUNITY DEVELOPMENT
CITY HALL
10300 TORRE AVENUE •CUPERTINO, CA 95014-3255
C U P E RT I N O (408) 777-3308 • FAX(408)777-3333•planningCc�cupertino.orq
January 9, 2015
jack Lin
6805 Westmoor Way
San Jose, Ca. 95129
SUBJECT:TWO STORY PERMIT ACTION LETTER—Application R-2014-38:
This letter confirms the decision of the Director of Community Development, given on January 9, 2015,
approving a Two Story Permit to allow the construction of a 2,409 square foot single family residence,
located at 18930 Barnhart Avenue,with the following conditions:
1. APPROVED PROjECT
This approval is based on a plan set entitled, "Mr. Biao Residence Rebuild, 18930 Barnhart Ave.,
Cupertino CA 95014-3669" consisting of ten sheets labeled "A1.1 to A3.3, CALG, C.Oand 3D", dated
May 12, 2014, except as may be amended by conditions in this resolution.
2. ANNOTATION OF THE CONDITIONS OF APPROVAL
The conditions of approval set forth shall be incorporated into and annotated on the building plans.
3. ACCURACY OF THE PROJECT PLANS
The applicant/property owner is responsible to verify all pertinent property data including but not
limited to property boundary locations, building setbacks, property size, building square footage,
any relevant easements and/or construction records. Any misrepresentation of any property data
may invalidate this approval and may require additional review.
4. CONSULTATION WITH OTHER DEPARTMENTS
The applicant is responsible to consult with other departments and/or agencies with regard to the
proposed project for additional conditions and requirements. Any misrepresentation of any
submitted data may invalidate an approval by the Community Development Department.
5. COMPLIANCE WITH PUBLIC WORKS CONFIRMATION FORM
The project shall comply with the requirements indicated on the Public Works Confirmation form,
including, but not limited to, dedications, easements, off-site improvements, undergrounding of
utilities, all necessary agreements, and utility installations/relocations as deemed necessary by the
Director of Public Works and required for public health and safety. The Public Works Confirmation
is a preliminary review, and is not an exhaustive review of the subject development. Additional
requirements may be established and implemented during the construction permitting process. The
project construction plans shall address these requirements with the construction permit submittal,
and all required improvements shall be completed to the satisfaction of the Director of Public Works
prior to final occupancy.
Two Story Permit Action Letter Page 2
R-2014-38
6. PRIVACY PROTECTION COVENANT
The property owner shall record a covenant on this property to inform future property owners of the
privacy protection measures and tree protection requirements consistent with the R-1 Ordinance, for
all windows with views into neighboring yards and a sill height that is 5 feet or less from the second
story finished floor. The precise language will be subject to approval by the Director of Community
Development. Proof of recordation must be submitted to the Community Development Department
prior to final occupancy of the residence.
7. LANDSCAPE PROTECT SUBMITTAL
Prior to issuance of building permits, the applicant shall submit a full landscape project submittal per
sections 14.15.040 A, B, C, and D of the Landscaping Ordinance if more than 2,500 square feet of
landscaping area is proposed. T'he Water-Efficient Design Checklist (Appendix A of Chapter 14.15),
Landscape and Irrigation Design Plans, and Water Budget Calculations shall be reviewed and
approved to the satisfaction of the Director of Community Development prior to issuance of building
permits.
8. EXTERIOR BUILDING MATERIALS/TREATMENTS
Final building exterior treatment plan (including but not limited to details on exterior color, material,
architectural treatments and/or embellishments) shall be reviewed and approved by the Director of
Community Development prior to issuance of building permits. The final building exterior plan
shall closely resemble the details shown on the original approved plans. Any exterior changes
determined to be substantial by the Director of Community Development shall require a minor
modification approval with neighborhood input.
9. INDEMNIFICATION
To the extent permitted by law, the Applicant shall indemnify and hold harmless the City, its City
Council, its officers, employees and agents (the "indemnified parties") from and against any claim,
action, or proceeding brought by a third party against the indemnified parties and the applicant to
attack, set aside, or void this ordinance or any permit or approval authorized hereby for the project,
including (without limitation) reimbursing the City its actual attorneys' fees and costs incurred in
defense of the litigation. The City may, in its sole discretion, elect to defend any such action with
attorneys of its choice.
10. NOTICE OF FEES,DEDICATIONS, RESERVATIONS OR OTHER EXACTIONS
The Conditions of Project Approval set forth herein may include certain fees, dedication
requirements, reservation requirements, and other exactions. Pursuant to Government Code Section
66020(d) (1), these Conditions constitute written notice of a statement of the amount of such fees, and
a description of the dedications, reservations, and other exactions. You are hereby further notified
that the 90-day approval period in which you may protest these fees, dedications, reservations, and
other exactions, pursuant to Government Code Section 66020(a), has begun. If you fail to file a
protest within this 90-day period complying with all of the requirements of Section 66020, you will
be legally barred from later challenging such exactions.
Please note that if this permit is not vested within a year, it shall expire on January 9, 2016.
Two Story Permit Action Letter Page 3
R-2014-38
Staff has made all the findings that are required for approval of a Two Story Permit as required by the of
Cupertino's Municipal Code, Chapter 19.28.140(A).
1. The project is consistent with the Cupertino General Plan, any applicable specific plans, zoning ordinances
and the purposes of this title.
The proposed project is consistent with the General Plan as the project is within the Low
Density land use area. There are no applicable specific plans that affect the project. The
project has been found to be consistent with the requirements of Cupertino Municipal Code
Chapter 19.28 Single Family (R-1) Residential.
2. The granting of the permit will not result in a condition that is detrimental or injurious to property
improvements in the vicinity, and will not be detrimental to the public health, safety or welfare.
The granting of the permit will not result in a condition that is detrimental or injurious to
property improvements in the vicinity, and will not be detrimental to the public health, safety
or welfare as the projects is located within the R1-5 (Single Family Residential) zoning district,
and will be compatible with the surrounding uses and neighborhood.
3. The proposed project is harmonious in scale and design with the general neighborhood.
The proposed project is located in a residential area consisting of single family homes. The
proposed project maintains the single family home scale found throughout the neighborhood.
4. Adverse visual impacts on adjoining properties have been reasonably mitigated.
Any potential adverse impacts on adjoining properties have been reasonably mitigated
through the privacy protection waiver form and installation of privacy protection trees as
required.
Also,please note that an appeal of this decision can be made within 14 calendar days from the date of
this letter. If this happens, you will be notified of a public hearing, which will be scheduled before
the Planning Commission.
Sincer ly,
Ellen Yau
Assistant Planner
(408) 777-1360
elleny@cupertino.org
Enclosures:
Approved Plan Set
CC:Biao or Young Ding, 18930 Barnhart Ave,Cupertino,Ca. 95014
0
GENERAL I� JTES
1. IT IS THE RESPONSIBILITY OF THE CONTRACTOR AND SUBCONTRACTORS TO
CHECK AND VERIFY ALL DIMENSIONS AND CONDITlONS INDICATED ON THESE
DRAWINGS AND MAKE KNOWN ANY DISCREPANCIES PRIOR TO COMMENCING
THEIR WORK.
2. THESE DRAWINGS ARE INTENDED FOR USE IN A NEGOTIATED CONSTRUCTION
CONTRACT AND,11iEREFORE,MAY NOT SPECIFlCALLY DETAILS OR SPECIFY
MATERIALS AND/OR MANUFACTURERS.
3. THE CONTRACTOR SHALL PROVIDE ALL SAMPLES AND/OR CUT-SHEETS AS
REOUIRED TO ASSIST OWNER OR HIS AGENT IN MAKING MATERIAL SELECTIONS.
4. FOR THE PURPOSE OF ESTIMATING, THE CONTRACTOR SHALL USE THE
MATERIALS SELECTED BY THE OWNER,OR IN ABSENCE OF SAME,HE SHAL�
PROVIDE AN ALLOWANCE AMOUNT AND SO CONDITION ANY COST ESTIMATE.
5. ALL MATERIALS SPECIFIED IN THESE DRAWINGS SHALL BE INCLUDED IN SUCH
ESTI M ATE.
6. NO GUARANTEE OF QUAUTY OF CONSTRUC110N IS IMPLIED OR INTENDED BY
THE CONSIRUCTION DOCUMENTS, AND THE CONTRACTOR SHALL ASSUME FULL
RESPONSIBILIN FOR ANY OR ALL CONSTRUCTION DEFlCIENCIES.
7. THE GENERAL CONTRACTOR SHALL HOLD HARMLESS,INDEMNIFY AND DEFEND
THE DESIGNER FROM ANY ACT10N INITIATED BY THE INITIAL OWNER OR ANY
SUBSEOUENT OWNERS FOR CONSTRUCTION DEFICIENCIES,MODIFICATIONS OR
SUCH CONDITIONS NMICH MAY BE BEYOND THE CONTROL OF 1HE ARCHITECT.
8. ALL WORK SHALL COMPLY WITH APPLICABLE CODES AND TRADE STANDARDS
WHICH GOVERN EACH PHASE OF WORK,INCLUDING BUT NOT LIMITED TO
CALIFORNIA BUILDING CODE(CBC), CALIFORNIA MECHANICAL CODE(CMC),
NA710NAL ELECTRICAL CODE(NEC),CALIFORNIA PLUMBING CODE(CPC), AND
ALL APPLICABLE LOCAL CODES AND LEGISLATION.
9. THE CONTRACTOR SHALL REVIEW AND RECORD THE CONDITIONS OF ALL
EXISTING SITE IMPROVEMENTS INCLUDING PAVED AREAS,HE SHALL MAKE
KNOWN ALL EXISTING DAMAGED OR DISREPAIRED ITEMS AND CONDITIONS THAT
MAY WORSEN DUE TO THE CONSTRUCTION.
10. ALL 17EMS IN GOOD CONDITION SHALL BE MAINTAIN IN THEIR PRESENT
CONDITION AND ANY REPAIR OR DAMAGE WHICH OCCURS DURING
CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.
11. CONTRACTOR SHALL THOROUGHLY EXAMINE THE SITE AND SATISFY HIMSELF
AS OF 1HE CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED.
12. TNE CONTRACTOR SHALL VERIFY AT THE SITE ALL MEASUREMENTS
AFFECnNG HIS WORK AND SHALL BE RESPONSIBLE FOR THE CORRECTNESS OF
SAME.
13. NO EXTRA COMPENSATION WILL BE ALLOWED TO THE CONTRACTOR FOR THE
EXPENSES DUE TO HIS NEGLECT TO EXAMINE OR FAILURE TO DISCOVER
CONDI110NS WHICH MAY AFFECT HIS WORK.
14. ALL NEW INTERIOR PAtNT COLOR,FLOOR,WALLS AND CEILING FINISHES
SHALL BE SEIECTED BY OWNER AT THE TIME WHEN IT IS NECESSARY FOR
THE COMPLETION OF P-IE PROJECT.
15. ALL PUBLIC IMPROVEMENTS SHALL BE MADE IN ACCORDANCE WITH THE
LATEST ADOPTED CITY STANDARDS.
16. THE STORING Of GOODS AND MATERIA�S ON SIDEWALK AND/OR STREET WALL
NOT BE ALLOWED UNLESS THE CONTRACTOR HAS APPLIED AND SECURED A
SPECIAL PERMIT WHICH ALLOWS SUCH STORAGE TO BE PLACED.
17. SPECIAL INSPECTIONS ARE REQUIRED FOR THE INSTALLATION OF EXPDXY
ANCHORS AND HOLDOWNS. SUBMIT A COMPLETED CITY OF CUPERTINO SPECIAL
INSPECTION AND TESTING SCHEDULE. TO OBTAIN FORM TO GO THE BUILDING
DEPARTMENT WEBSITE(WWW.CUPERTINO.ORG)UNDER FORMS AND GUIDES.
18. PROVIDE(2)WET STAMPED AND SIGNED COPIES OF A REVIEW LETTER FROM
THE GEOTECHNICAL/CIVIL ENGINEER FOR THE FOUNDATION PLAN AND DETAILS
TO SHOW THAT HE/SHE HAS REVIEWED THEM AND TAHT 1}iE OVERALL
PROJECT DESIGN IS IN GENERAL CONFORMITY WITH THE GEOlECHNICAL SOILS
ENGINEERING RECOMMENDATIONS FOR THE PROPOSED CONSTRUCTION.
SCOPE OF WORK
1. NEW 15T FLOOR INCLUDES: (N)PORCH,(N)LJVING RM.,(N)POWDER RM.,
(N)LOBBY, (N)BATH#1, (N)BEDROOM #1, (N)LAU.
(N)FAMILY RM.,(N)KITCHEN AND(N)DINING RM.
NEW 2ND FLOOR INCLUDES: (N)BEDROOM#2, (N)BEDROOM #3, (N)M.BEDROOM,
(N)M. BATH,(N)BATH �2 AND(N)LOUNGE.
THE TOTAL 1ST FLOOR iS 1,617 S.F. (GARAGE 442 INCLUDED)
2ND FLOOR IS 792 S.F.
2. ALL NEW WINDOWS ARE DOUBLE PANEL.
3. INSTALL NEW ROOF,ROOFING TO BE LT. WT. CONC. TILE ROOF.
4. NEW EXTERIOR STUCCO FINISHED.
5. RELATED ELECTRICAL,MECHANICAL AND PLUMBING WORK.
6. (N)ELECTR�CAL PANEL TO BE 200 AMP.
7. (N)GAS MTER.
SYMBOLS
BLDG G. .TA
SITE AREA: 1229 ACRE Q
5,355 SQ.FT.
EXISl1NG BUILDING FLOOR AREA(ALL DEMOLISHED) 0
FLOOR AREA: 1ST FL 1,080 SQ.FT.
2ND FL 0 SO. FT.
CARPORT 225 50. FT.
TOTAL EXISTING FLOOR: 1,080 SQ. FT.
PROPOSED ADDITION FLOOR AREA
LIVING+GARAGE AREA:1ST FL 1,645 SQ. F.�
2ND FL SQ.FT.
2ND FL./15T FL. RAT10= 46.35 7. Q
PORCH(UNCOUNTED) 50 SQ. FT.
GARAGE 443 S0. FT.
TOTAL PROPOSED FLOOR z•40� SQ. FT.
MAX. ALLOWED FLOOR AREA
5,355 X 45�= 2.409.75 SQ. FT.
TOTAL FLOOR AREA
1,202+ 762+443= 2,�� S0. FT. �
F.A.R.: 2,407/5,355= 44.95 7.<45:
MAX. LOT COVERAGE fOR R-1 Z NE I 45i =
1,927/5,355= 35.99 9<459�
LANDSCAPE AREA: 2.85� SQ. FT.
LANDSCAPE COVERAGE 53.22 9;
APN: 375-33-007
ZONE: R1-5
OCCUPANCY: R-3/U
CON5IRUCTION TYPE: V-B
570RY(IES): 2
AUTO. FIRE SPRINKLER: YES
DESIGN COMPLY WITH:
2013 CBC Ed.
2013 CRC Ed.
2013 CFC Ed.
2013 CMC Ed.
2013 CPC Ed.
2013 CALIFORNIA ELECTRIACL CODE Ed.
2013 CALIFORNIA ENERGY CODE Ed.
_ 2013 CALIFORNIA GREEN BUILDING CODE Ed.
VICINITY MAP
� « � _ ��_.
� � �q -
� �� � , 6
'�, � ,��
� �
�r � � :.:.F;
� i .�' yn
�
��� �
��C3�4 � .�"��5+C�1''�'��'.
� 'T��t�r��r�c+ga'.
�'�C'!td�a5t�ti�e.� � '....�
i
� �
!: �'
�
�::::
' 1tllittgW�Fay.
P�Ss�?'�
�
•I '
�
I
� �
1
I
I
� ol
o�
nl
0
�
I
I
I
i
I�li l -�� I
,; , �'�.: �� C�
� ; � ` �, E; _..
�0. � >4 �,� � _
�. % � .. ...
. ,;
..
� � ,
� � �:
:��'.�t�fl!��P � �� '�j�. .
1�t '�
.�r
... :.;����4"�S@t1�R��exa .?�: ;+k.F�e�` ,..
SHEET INDEX
A1.7 TITLE SHEET & SITE PLAN
�•� LOT COVERAGE
A2.1 PROPOSED 1 ST FLOOR PLAN
�•2 PROPOSED 2ND FLOOR PLAN
A3.1 (N) ELEVATIONS
A3.2 (N) ELEVATIONS
A3.3 ROOF REF. & SECTION
;ALG CALGREEN RESIDENTIAL CHECKLIST
C.O SITE SURVEY
( /� �COLUMN GRID LINE N0. O EXIS�ING DOOR 3D
�/ 3D PERSPECTIVE RENDERING
NO SECTION N0. Np DOOR N0.
A.X � SECTION SHEET N0. A � DOOR SCHEDULE i,,
DOOR TYPE
NO ELEVATION N0. N� INlERIOR ELEVAT10�r,� .
q -..:. �.�'^"^_'r-
M
A.X ELEVATION SHEET N0. A�x INDICATOR �� `t`$��' "
x i'^
y, , ,. . � .:.,
DETAIL N0. 6.> � 3��
NO RM.< ROOM NAME ,';,E �_ �
t
FLOOR FINISH `
, . ,.....
DETAIL SHEET N0. F�' E (�:
,�, ., ..
� 'ak� i i 7�'',f:
, .....,:....
il rn, ;
REVISION N0.
e.uwYlNiolrt'i.�J:Ki'J'Y:Ad.MY.w+ifi'�^.
,..-<-„_.-s
�r v/ '�'I f�
�
I
1
�
EN E REBUILD
MR
. BIAO R
ES
ID C
18930 BARNHART AVE., CUPERTINO, CA 95014-3669
,s-o• � . e'-�'
r,,;W;�ll�
� xo.o
�---
��
���
762 SF
6'-7" 6'-0' 15'-0' �
�
51.00'
---- - �------�
(
I
0
(�o'�xs'7 /
/54 (ry /
i mw.a�. �^�a1a /
c� a��--
woowvu Q� �':
I
�-------� I
I I ',
� cN�u.emrsoou I j
� xo.o �
I I I
L------J
�---�
j[�1 BEnROOU�SI
� ro�l
��___J
I�� --a �`��
LYJ
�-
---� i
� �
IN1 STAIR Ho.o �
°'D I I
v,'nrcx'G � L---J I
n
rzw a
(MYlp�O
: .. . ............ ..CORESS ... ......:.
, .. .
is'-o' �1 z'-io' a•-io• i3'-<� _ is._p.
I
�
�
�---------------
51.00'
•NOTE: 0 si-o-
THE TREE IN THE N RTHWEST
CORNER IS A SlREET TREE. THIS
WILL NEED TO BE PROTECTED
DUTING CONSTRUC110N.
AN ISA-CERTIFIED ARBORIST WILL
BE REOUIRED TO VERIFY Tl-IE
SPECIES AND HEALTH OF THE TREE
AND THAT TREE PROTECTION
MEASURES ARE IN PLACE PRIOR TO
CONSTRUCTION. THE ARBORIST WILL
ALSO NEED TO VERIFY THE HEALTH
OF THE TREE.
'�' -
��-
�y�.�. �.
...�. �B�x�r�r�.._...._
�,�- .-�=,,,
762 S F °
CITY STANDARD TREE PROTECTION MEASURES �
IN
I�
��
I
�
�
0
s-o- ai-o' s'-o'
(N)15 ALLON -•.---.. (N)15 GALLON
ITALJAN CYPRE55 ITALIA CYPRESS
6'HT. 51.00' 6'HT.
�- --- --- -- -- -- - =---- _ --i
� '0010"tREE(S)
;' � �� 5' P.U.E.�� �.. �.
�� 12"PALM __ _ _ _�
, ---- ..- _ ,,
� ;' LANDSCAPE 2,850 SF �
�� .: ; I ;
< _�w , ;:; _ . � °
� (N) 15 GALLON �
( ITALIAN CYPRESS I
(N)75 GALLON � 6'HT. '... I
ITALIAN CYPRESS " �
6'H T.
,.
� • ` ;,.
�. .:� __..._ .._... .._. . _._ _I
I �Z�-„� J I
� v (E)PEACH iREE � „
� TO REMAIN ; ,o
� , DIA. 0'-6" ;,.<i
,I �.I .. . ., ����.)
� '; 8-0- sF I
� � i� �
I � °......:..... _o.. 12"TREE�S) �°°
�
, ,< . ..
, , .
� : an•o•x..o. .� .:; � . . '.1
� . ; .: ..............„. ,.. .
��� c���.� ,r I
;' °::; 'i
. r • •
(N) 15 ALLON I �MNV
_ ITALIAN C RESS � (N)KITCHEN (Nl FAYI:Y R11
6'HT.���.� , nF " xc.o
.;
� : I �
� y I nDwo (N)PAN7RY
� � I MDYO
'a oi +� � -------- II--11� / If
o . „RO_
� �
� � �
,i
i ��
I i
I
.�� �
�
�.N� � i
��, •' I�1
I� ��
�1
�- �
l i �, �
`II • •
��
�L : • � ._�
xrt(Nl L.Wd�G
�a�
zo'-o'
.o
Ml 2c�AR CAR,
, aa2 tl9F
__,_, i/I!o:
i
��
. :.3'I' -
� , �I�I_ ��
'J���°.i�
�i!!� �
�iRUB I
!� '�:::
6"HT.
�
I ..... F'�'O y,�7"S � . _
.,. ...,. ...
.....:::.:�'n�.c (N)6'0'�!'0' 'l,p ... ..,._.O
Q. SDMG/SG. E�F �
i rtu>.a �..,. �'.
H
�..
c, �
m
<. e ,o
50 SF, � �
I . ._ . � ,. �.. 1
I. .. .. , k�'�.. R� . �x ..
� � , e
i � i
� G 17-10' ,n Q
� I
6.-0. I 5'-0" 3'-1' 6'-11"N '-0 '-6 a'-8' . .. . a 6� ..'S-0�
24"TREE '
� � �
I "� C IV�, IMPERVf US 378�SF
L . � J
------�-� ------- ---- - -
51.00' 30"TREE
NOTE: CONSiRUCT SIDEWALKS, WALKWAYS
0 AND/OR PATI05 WITH PERMEABLE SITE PLAN
SURFACES.
�NOTE: PRIOR TO ISSUANCE OF BUILDING scn�:i/a'-i'-o"
PERMIT, 1HE LANDSCAPE WATER-EFFICtENCY
CHECKLJST IN APPENDIX A OF CHAPTER 14.15
WILL NEED TO BE FILLED OUT AND A FULL �q
LANDSCAPE PROJECT SUBMITTAL PER SECTION
14.15.040 WILL BE REQUIRED.IT IS PREFERRED
THAT THIS INFORMATION BE PROVIDED AT THE
T1ME OF THE PLANNING ENTITLEMENT.
•NOTE: USE ONE OR MORE OF DESIGN
MEASURES BELOW,
A. DIRECT ROOF RUNOFF ONTO
VEGETATED AREAS.
B. DIRECT ROOF RUNOFF INTO
CISTERNS OR RAIN BARRELS FOR
REUSE.
C. DIRECT RUNOFF FROM SIDEWALKS,
WALKWAYS, AND/OR PATI05 ONTO
VEGETATED AREAS.
D. DIRECT RUNOFF FROM DRIVEWAYS
AND/OR UNCOVERED PARKING LOTS
ONTO VEGETATED AREAS.
E. CONSTRUCT SIDEWALKS,WALKWAYS
AND/OR PATI05 WITH PERMEABLE
SURFACES.
1 202 SF �°
i
50 SF
GARAGE
443 SF
WHY
Constuction
DESIGNER
Jack Lin CSLB#964820
6805 Westmoor Woy
San Jose,CA 95129
TEL: (408) 218-0587
Email: fu333�yahoo.com
NI deaa Eevq�a,wrongemente k Olan¢
�naco+N o.re{+rexnled by Mn arwinq
o.��e ey o�e<n��,.ty oe
A 9 YCOrRUC11lMI
a�a "an ca�Ke aoa e�.�oP�a
ra a cb�»�m,
th q 'fietl project. Norie ol vu�
�ee.eh�v��.o,a�y.,��t.o.a^�e
ohdl be ueedm co dxlosed lo y
pmm.firm ryoration im ony
p�rpove M�aleoevm It�wl N<
nM v�r.���o�
w�e r caavuctw„
ui�nro.m�a�w�n<s� m<a ey m
p�,�.. vao� a vos�t
eDRemtohvea M t il ttlty tnex.
ShoWd anY�^w fl'l nc�nalelmcy
����u�a��y.tn-orco.m��c
�
be nobf d tar n�tr t' proir to
proceeEng t�a y sWctbn.
OWNER:
MR. Bao Ding
TEL: 408-828-9808
EMAIL: ghifeng�yahoo.com
MR, Young Ding
TEL: 408-623-5809
W
� ■
z W �
W Q M
� ,
� t
� � �
�:i
�
W = ,Q+
� Z v
� Q Z
z °0 �
� � W
Q M p.
��/� _ '
■ W U
� !�
�
TITLE SHEET
�
SITE PLAN
�a,�: 05/12/14
�oa No. WHY14-0542
ISSUE&REVISION
07/02/14 LANNING REVIE
10 11/17/14 LANNING REVIE
12/04/14 LANNING REV1E
3
4
5
6
7
8
9
10
11
SHEET N0.
A1 .1
DRAWN BY: JL
DEMOLITION NOTES
1. THE GENERAL CONTRACTOR SHALL FURNISH ALL LABOh �MATERIALS AS
REQUIRED TO COMPLETE DEMOLITION AND REMOVAL OF ALL ITEMS INDICATED
ON RC USA DRAWINGS OR AS OTHERWISE DIRECTED BY THE OWNER.
2. THE CONTRACTOR TO VIEW AND VERIFY ACTUAL CONDITIONS AT ALL
LOCATIONS WHERE ALTERATIONS TO THE EXISTING BUILDING OCCUR. WHEN
WALLS, PARIITIONS, AND OTHER WORK EXISTS WFiERE NEW WORK IS
INDICATED, ALL SUCH EXISTING WORK SHALL BE REMOVED. VERIFY A�L SUCH
CONDI110N5 AT THE SITE.
3. THE CONTRACTOR SHALL REPORT TO ARCHITECT ANY AND ALL CONDITIONS
WHICH MAY INTERFERE WITH OR OTHERWISE AFFECT OR PREVENT THE
PROPER EXECUTION AND COMPLETION OF THE WORK OF THIS CONTRACT.
4. THE GENERAL CONTRACTOR SHALL EXECUTE ALL WORK WITHIN THE
REGULAl10NS OF THE BUILDING FOR DEMOLITION AND REMOVAL OF DEBRIS,
INCLUDING OVERTIME WORK REQUIRED.
5. THE GENERAL CONTRACTOR SHALL AT ALL TIMES PROTECT THE PROPERTY
OF THE BUILDING LANDLORD INCLUDING, BUT NOT LIMITED TO FLOOR
COVERING, CEILING GRiD AND TILE. LIGHT FIXTURES, DOORS, WINDOWS,
FRAMES, HARDWARE, CABINETRY, PLUMBING FIXTURES, ELECTRICAL AND AIR
CONDITIONING EQUIPMENT, PERIPHERAL ENCLOSURES, ETC.
6. THE GENERAL CONTRACTOR SHALL ERECT ALL NECESSARY PLASTIC DROP
CLOTH BARRIERS TO PROTECT ADJACENT BUILDING PROPERTY WHILE
DEMOUTION AND CONSTRUCTION ARE IN PROGRESS.
7. THE GENERAL CONTRACTOR SHALL SURVEY ALL EXISTWG FINISHED
SURFACES TO INCLUDE CORNER BEADS, STOPS, ETC., FOR CHIPS, CRACKS,
HOLES, DAMAGED SURFACES, AND ANY OTHER DEFECTS CAUSING AN
APPEARANCE DIFFERENT FROM A NEW,FINISHED, INSTALLATION. THESE
DEFECTIVE SURFACES SHALL BE REPAIRED OR, IF BEYOND REPAIR, THE
GENERAL CONTRACTOR SHALL REMOVE ALL EXISTING AND INSTALL NEW
SURFACES TO THE SATISFACTION OF TSCGI AND THE OWNER.
8. THE GENERAL CONTRACTOR SHALL INSPECT ALL EXISTING SURFACES AND
WHERE AS A RESULT OF DEMOLITION, FINISHED SURFACES DO NOT ALIGN,
THE EXISIING SURFACE SHALL BE CUT AND PATCHED.
9. ALL DAMAGED ExISTiNG AREAS TO REMAIN AND EXISTING AREAS AFFECTED
BY DEMOLITION OR NEW CONSTRUCTION WORK SHOWN ON DRAWINGS SHALL
BE PATCHED AS REQUIRED TO MATCH IMMEDIATE EXISTING ADJACENT AREAS
IN MATERIAL, FIRE-RATING,FINISH, AND COLOR, UNLESS OTHERWISE NOTED.
10 ALL WORK DEMOLISHED SHALL BE REMOVED FROM THE PREMISES EXCEPT
iTEMS TO BE REUSED OR RETURNED TO THE OWNER OR AS OTHERWISE
UIRECTED.
11. IN ALL AREAS WHERE DEMOLITION (REMOVAL OF TILE, PARTITIONS, ETC.
CAUSES AN UNEVENNESS IN THE SLAB, THE CONTRACTOR SHALL PATCH TO
LEVEL THE SLAB TO F'r CEIVE NEW FINISH FLOOR�NG.
12. ALL EXPOSED LIGHT FIXTURES, WIRING, SWITCHES, CONDUIT,AND METAL
MOLDING NOT BEING REUSED SHALL BE REMOVED AND EITHER STORED OR
DISPOSED OF BY THE GENERAL CONTRACTOR AS INSTRUCTED BY THE
OWNER.
13. THE GENERAL CONTRACTOR SHALL FURNISH A SYSTEM OF TEMPORARY
LIGHTS THROUGHOUT THE SPACE UNDER DEMOLITION AS REQUIRED.
14. THE GENERAL CONTRACTOR SHALL CAP OFF BEHIND FINISHED SURFACES
ALL PROJECT PLUMBING,FLOOR ELECTRICAL/TELEPHONE OUTLETS, AND ALL
OTHER PROJECTING ITEMS THAT ARE BEING ABANDONED.
15. TNE GENERAL CONTRACTOR SHALL REMOVE ALL WALL CONDUITS LEFT AFTER
WALL DEMOLITION INCLUDING SWITCH BOXES, PLATES, BRIDGES, OR ANY
OTHER TELEPHONE OR ELECTRICAL WIRING OR EQUIPMENT. VERIFY WITH
TENANT REUSE OF EXISTING CABLING PRIOR TO REMOVAL.
16 ALL��EXISTING TO REMAIN", °EXISTING��, "REI.00ATED", OR "NEW" ITEMS
INSTALLED BY THE GENERAL CONTRACTOR, IN ADDITION TO BEING AMPLY
PROTECTED THROUGHOUT THE PERIOD OF CONSTRUCTION, SHALL BE
THOROUGHLY CLEANED TO THE SATISFACTION OF TSCGI PRIOR TO BEING
TURNED OVER TO THE OWNER.
17. REFER TO ENGINEERING DRAWINGS FOR REMOVAL AND/OR RELOCATION IF
REQUIRED OF HAVOC DUCTS, DIFFUSERS, SPRINKLER HEADS, EXIT LIGHTS,
ETC.
18. SOME DOORS AND FRAMES TO BE REMOVED SHALL BE RETURNED TO
OWNER. HANDLE CAREFU�LY AND STORE ON SITE.
GENERAL DEMOLITION NOTES
1. THE GENERAL CONTRACTOR AND ALL SUB-CONTRACTORS SHALL
THOROUGHLY FAMILIARIZE HIMSELF WITH THE EXISTING CONDITIONS OF THE
PROJECT AND THE CONTRACT DOCUMENTS IN ORDER THAT DEMOLITION
WORK WILL INCLUDE DEMOLISHING ALL iTEMS INCIDENTALS, WHETHER CALLED
FOR OR NOT.
2. THE GENERAL CONTRACTOR SHALL REVIEW THE DRAWINGS AND
SPECIFICATIONS TO COORDINATED WITH EXISTING BUILDING CONDITIONS. ANY
VARIANCE OR DISCREPANCY THAT ARISE FROM ABOVE REVIEW SHALL BE
REPORTED TO THE ARCHITECT IMMEDIATELY FOR RESOLUTION.
3. CONDUIT DEMOLITION TO MINIMIZE INTERFERENCE WtTH ADJACENT
STRUCTURES.
4. PROVIDE, ERECT, AND MAINTAIN TEMPORARY BARRIERS AND SECURITY
DEVICES.
5. ANY STRUCTURAL SUPPORT, BRACING AND SHORING NEED TO HAVE
ENGINEER REVIEW PRIOR TO COMMENCE THE WORK.
6. LOCATE EXISTING UNDERGROUND UTILITIES IN AREA TO AVOID DAMAGE BY
DEMOUTION.
7 ALL DEMOLITION WORK TO BE PERFORM CAREFU�LY, ITEMS TO BE REMOVED
NEED TO REMOVE,DUMP AT LEGAL DUMP SITE,CLEAN THE WORK AREA
AND PREPARE THE AREA TO RECEIVE NEW WORK AS SPECIFIED ON THE
DRAWINGS.
8. BACKFILL AREAS EXCAVATED AND OPEN PITS AND HOLES CAUSED BY A
RESULT OF DEMOLITION.
9. ROUGH GRADE AND COMPACT AREAS AFFECTED BY DEMOLITION TO MAINTAIN
SITE GRADES AND CONTOURS.
10. UNLESS WHERE NOTED OTHERWISE, IMMEDIATELY REMOVE DEMOLISHEU
MATERIAL FROM SITE. LEAVE SITE IN CLEAN CONDITION.
11. DO NOT BURN OR BURY MATERIALS ON SITE.
12. REMOVE AND PROMPTLY DISPOSE OF CONTAMINATED, VERMIN INFESTED, OR
DANGEROUS MATERIALS ENCOUNTERED. REPORT TO ARCHITECT AND RELATED
AGENCIES AS REQUIRED.
13. CONDLIIT OPERATIONS WITH MINIMUM INTERFERENCE TO USE AND THOROUGH
PUBLIC WAY. MAINTAIN PROTECTED EGRESS AND ACCESS AT ALL TIMES.
14. DO NOT CLOSE OR OBSTRUCT ROADWAYS OR SIDEWALKS WITHOUT PERMITS.
15. ANY PIPE, CONDUIT, OR CABLE ORIGINALLY CONNECTED TO THE REMOVED
ITEMS TO BE DISCONNECTED AND CAPPED PROPERLY. IF THE ITEMS IS PART
OF A SYSTEM THEN NEED TO RE-CONNECT TO EXISTING SYSTEM AND KEEP
IN A WORKING CONDITION.
16. THE LOCATION OF DISCONNECTED AND/OR CAPPED LINES SHALL IDENTIFIED
PUBLIC WORKS NOTES
1. ONSITE DRAINAGE (WITH ARROW AND SLOPE PEF ,GE) NO
CONCENTRATED FLOW ACROSS THE RIGHT-OF-WA�. rv0 DRAINAGE ONTO
NEIGHBORING PROPERTIES. ALL DRAINAGE TO LANDSCAPE SEE ADDITIONAL
COMMENTS#6.
2. CLEARLY SHOW ALL UTILITIES FROM THE HOUSE/PROJECT SITE TO THE
STREET(ELECTRIC, ELECTRIC PANEL, GAS, WATER, SEWER), INDICATE AS
NEW(N)OR EXISTING(E).
3. APPROVAL OF THESE PLANS DOES NOT RELEASE HE OWNER AND/OR
CONTRACTOR OF THE RESPONSIBILITY FOR THE CORRECTIONS OF MISTAKES,
ERRORS, OR OMISSIONS CONTAtNED THEREIN. IF DURING THE COURSE OF
CONSTUCTION IMPROVEMENTS, PUBLIC INTEREST REQUIRES A MODIFICATION
OF/OR A DEPARTURE FROM THE CITY OF CUPERTINO SPECIFICATION OR
THESE IMPROVEMENT PLANS, THE CITY ENGINEER SHALL HAVE THE
AUTHORITY TO REQUIRE SUCH MODIFICATION OR DEPARTURE AND TO
SPECIFY THE MANNER IN WHICH THE SAME IS TO BE COMPLETED, AT 7}-IE
SOLE EXPENSE OF THE OWNER AND/OR CONTRACTOR.
4. CONTACT PUBUC WORKS, (408) 777-3104, FOR INSPECTION OF GRADING,
STORM DRAINAGE, AND PUBLIC IMPROVEMENTS.
5. ALL PUBLIC IMPROVEMENTS MUST BE COMPLETED PRIOR TO OCCUPANCY.
6. CONTRACTOR IS RESPONSIBILE FOR DUST CONTROL AND ENSURING THE
AREA ADJACENT TO THE WORK IS LEFT IN A CLEAN CONDICTION.
7. CONTRACTOR SHALL REVIEW CITY DETAIL 6-4 ON TREE PROTECTION PRIOR
TO ACCOMPLISHING ANY WORK OR REMOVING ANY TREES.
8. UTILIZE BEST MANAGEMENT PRACTICES(BMP'S), AS REQUIRED BY THE
STATE WATER RESOURCES CONTROL BOARD,FOR ANY ACTIVITY, WHICH
DISTUR85 THE SOIL.
9. A WORK SCHEDULE OF GRADING AND EROSION &SEDIMENT CONTROL PLAN
SHALL BE PROVIDED TO THE CITY ENG�NEER BY AUGUST 15. NO HILLSIDE
GRADING SHALL BE PERFORMED BETWEEN OCTOBER 1 TO APRIL 15.
10. ALL NEW ELECTRICAL SERVICE(POWER, PHONE, AND/OR CABLE)SHALL BE
UNDERGROUNDED.
11. TO INITIATE RELEASE OF BONDS, CONTACT THE PUBLIC WORKS INSPECTOR
FOR FINAL INSPECTION.
12. ALL DOWNSPOUTS TO BE RELEASED TO THE GROUND SURFACE, DIRECTED
AWAY FROM BUILDING FOUNDATIONS AND DIRECTED TO LANDSCAPED AREAS.
13. PRIOR TO BEGINING ANY WORK WITHIN THE PUBLIC RIGHT OF WAY, THE
CONTRACTOR WILL BE RESPONSIBLE FOR PULLING AN ENCROACHMENT
PERMIT FROM THE PUBLIC WORKS DEPARTMENT.
* NOTES: �
A. "THE PROPERTY OWNER SHALL RECORD A
COVENANT ON THE PROPERTY FOR THE NEW
TREES/SHRUBS PLANTED FOR THE PURPOSSE OF
PRIVACY PROTECTION, AND REQUIRED FRONT YARD
TREE."
B. "FOLLOWING COMPLETION OF PLANTING, AN
AFFIDAVIT FROM THE ISA-CERTIFIED ARBORIST SHALL
BE PROVIDED CONFIRMING THAT THE NEW TREES HAVE
BEEN PLANTED PROPERLY AND ACCORDING TO
APPROVAL PLAN."
C. "A PLANNING DIVISION INSPECTION IS REQUIRED TO
VERIFY EXTERIOR MATERIALS/FINISHED, TREES,
LANDSCAPING, AND OTHER SITE WORK."
RESIDENTIAL PROJECT
COVER SHEET
ASSESSOR'S PARCEL NUMBER: 375-33-007
NAME OF OWNER. MR.BIAO D�NG
PROJECT ADDRESS.18930 BARNHART AVE.,CUPERTINO
CONTACT PERSON. MR. JACK LIN PHONE. 408-218-0587
FAX.
NET SOUARE FOOTAGE OF LOT. 5,355 S.F
z
EXISTING PROPOSED
SQUARE FOOTAGE: FIRST FLOOR: 1,080 1.202
SECOND FLOOR: 762 �
GARAGE: 225 CARPORT 44
TOTAL: 1.080 2.407
ARE THERE AT LEAST TWO 10 FOOT BY 20 F00T CLEAR SPACES INSIDE
THE GARAGE? �y N
IS PRIVACY PROlECTION PLANTING REOUIRED FOR THE PROJECT? YO N
BUILD IT GREEN TOTAL POINTS N /A
ON WHAT FLOOR(S)IS WORK BEING DONE? NO
BRIEF DESCRIPTION OF WORK. NEW FLOOR INCLUDES:
1ST FL� (�LIVING RM.(N)PORCH.(N)POWDER.(p{)LOBBY.(N)2 CAR GARAGE
(N)BATHROOM #�1. (N)BEDROOM#t. (N)FAMILY RM.,(N)KITCHEN AND(N)DINING
2Nf FL. : (N1 BEDROOM �2. (l�BEDROOM �3.{�1 M. BEDROOM (Ni M. BATH
AND(N)LOUNGE
CODE EDITIONS:2013 CBC (Y N)2013 CFC (Y N)2013 CMC (Y N)
2013 CPC (Y N)2013 NEC (Y N)
EFFECTIVE 1/1/11
2ND FL AREA ENCLOSED BY 2ND FL EXIERIOR
WALLS 782 S.F.
(2ND FL.ROOF EAVES ExCLUDED)
�
2ND FL AREA ENCLOSED BY ROOF EAVES
908 S.F.
(2ND FL.ROOF EAVES INCLUDED)
�
51.00'
O' ��
� 10'TREE(S) �
12"PALIA.
(N)15 GALLOH+ - . s .� . .•. .�-.�I N)15 GALLON
ITALIAN CYPRESS� � -�
6'HT. . ��'�f �'�� -TALIAN CWRESS
HT.
ITALIAN CYPRE55� ���� �����)15 GALLON
6'HT. .� - ' ' ��TALIAN CYPRESS
(N)15 GALLON� <. ..�. �`�6'HT.
ITALIAN C1PRE55t ., ��� �. ;� � N)15 GALLON
6'HT.j ..: .... �, .� .. .::.�TALIAN C1PRE55
(N)15 GALLONI � � . .� HT.
ITALIAN CYPRESSI .-:� .-.� .� :-��.�: .�.` �� �� �.. N)15 GALLON
6'HT. : ��� �- � �-��TALIAN CYPRESS
� ........... . .._..... .. �.. � 'HT.
(N)15 GALLON� �� � -
ITALIAN C1PRE55� -� �� �� 15 CALLON
6'HT. .( .CYpRESS
� .. . . Ki'::HT.� .
r� ����� �
� . .. •. � 6' aawnu Y .�.. ..,...'..,� .�1
;+'�Fo% �'Y�� I
�� �
.12"fREE(S)� �
(N)15 GALLON . .. ',. r-----, � <<..�,,�.:
ITALIAN C1PRE55�.... � ....��..br�� �•TREE O I
6'HT. ..��, � rwi��.,+.,�� � .
I` I I I Y ',':�:, �� N)1 aILON
ITALIAN SCYPRE55 l .-.. �� j� L-----J � 'jREEO ..�TA WRESS
6'HT. , T.
N 15 GALLON� I r__ I '�. N)15 GALLON
�� '� 'ITA CYPRESS
ITALJAN CYPRESS� . ' ��1�uc f---1 � ,
6'HT. � � L-- �����,�„,,,��� �pgJ. T.
(N)15 GALLON I' .......`I ' ' F�ry�� 15 GALLON
ITALIAN CYPRESS --J � � T IAN CYPRESS
6'HT.� ������� (n11� I� ��.6SF�i T.
1 �-�-� 762 SF 0 , �s�N)15 GALLON
� .....•� � .,-. �..T IAN CYPRESS
��I � �/ bea.� HT.
b� � L�J � t,�� �(N 15 GALLON
o�X . . �:�TA AN CYPRESS
--� I �'
. I . �! 15 GALLON
I �y�g M�",�0°"�I I :�pTpLI�qN CYPRE55
I I j6 Ri.
i �f� �au � �-_� I .. ,,O
1�
� v �cac4bLas
,..
I ..,. _.......,,............ .......
� r., ..<.;..
i . ,.. '
� �
� � �
� Q24'TREE �
( ,. 30'TREE I
� `,:%::;....�
L----------- -------�J
BARNHART AVE.
2� SF
-----,
,---
-- � �-,
� �
I I
I �
I �
I �
I �
I �
I �
� I
I �
�
� 762 SF ;
I �
I �
�-, I
� I
I �
I �
� ,
I �
I__ �
I �
�---- �
51
�
•NOTE:
IN ORDER TO USE 7HE ExISTING 7REE5 AS PART OF
THE PRIVACY PLANNING.THE CITY REWIRES A LETTER
fROM AN IN7ERNATIONALLY CERTIFlED ARBORIST OR
UNDSCAPE ARCHIiECT STATING TAHT THE TREES
PROPOSED VALL MEET OR ExCEEp HEIGHT,SPREnD
AND GROWTH RATE.
SHALL DWBLE CHECK AND FOLLOW UP WI1H
LANDSCAPE DE9GN BY LANDSCAPE ARCHITET IN THE
BUILDING PERMIT SET LAiER.
+NOTES: Q
LANDSCAPES WITH MORE 7NAN 2,500 SOUARE FEET
N7LL NEED TO COMPLETE A LANDSCAPE SUBMITTAL
THIS CAN BE COMPLETID CONCURRENTLY WIlH
BUILDING PERMIT.
1 PRIVACY PLANTING
N TS
�
15T FL&2ND Fi.AREA ENCLOSED BY ALL EXTERIOR
WALLS 1,750 S.F.
(GARAGE 443 SF k PORCH 50 SF INCLUDED)
,-------
I _
� � I
I � I I
I � I I
� , , �
I
� i 202 SF � '
i � � I I
� , � �
I � I I
� � I
I � i I
� � I I
I � I I
I �_� I I
' ' GA G E �
I �
I
' 44 �SF �
I
� �_ I I
� j I I
I �--- -------I I
I �
� `� ,, PORC ; ----'
----- � 50 SF �
I I
° �;� �::':.. ; .; �-�i��- ,��� LOT COVERAGE: =1,927/5,355=35.99%<45% �
:. , ....... _�_....._,�,---,..ad�yC!.��...:.�......r.�.�m
` �.' ` ��� �!`P`� 18930 BARNHART AVE.
. � tie�. �
a� '.';; �.:) r 4�1�.:. . -...,.,.-..����%�......mo,..r,,....�...s-
� �,:k.,'i ..t,+,:. ... .�...
`i . _. ,.,.Y. ....,...,�t.....P<d ..a,,....,�,.....r.�.�...,
�������t,<'��ti
.�i�i.h �.
��!] ��1Ynri. ��_���a
�ICA�� ....i�� �
15T FL AREA ENCLOSED BY 15T FL.EX7ERIOR WALLS
1,202+443+50�1.695 S.F.
(GARACE 443 SF dc PORCH 50 SF INCLUDm)
0
LOT COVQ2AGE AREA 1,92�S.F.
(INCLUDES 1ST FL STRUCNRE,ROOF OVERHANGS,
COVERD PORCH AND ANY PORTION OF THE SECOND
STORY THAT COVERS THE LAND BUT NOT INCLUDED
IN THE FlRST FLOOR AREA.)
2 LOT COVERAGE
N TS
WHY
Constuction
DESIGNER
Jack Lin CSLB jJ964820
6805 Westmoor Way
San Jose,CA 95129
TEL: (408) 218-0587
Email: fu333�yahoo.com
ui e�.e�y�..a,.a�ya„��ie e piao.
inbcated a r�pra+enled by}hn dm�ing
�.e nr a�a m.y��.cy m
w a ecoisnnc�
�a ��a �.<a a�e ee�wea
ror uce on. a cb�.rn.
the epecfwE pr�jecl. NoM o�w h
w�e�s�.. �.�c, p�,
enan ne�xda cw d�oxe�o y
Dmon,firtn porotion�v ony
P��oe�.na�s«�.uno�,i me
tta,�e.�or
w e vcaenuc�
ui mo�ai��.�o ee.<.m�e ey w
GO V� 4D Rt
p t t M t il lA ty t^n�.
Sh Id y fl t tency
ppea'lh ba g N' ffi e muat
n ure� �wo o to
P.o�e�a��y.�u,aoy��.c�,<e�o�.
OWNER:
MR.Bao Ding
1EL: 408-828-9808
EMAIL: ghifeng�yahoo.com
MR. Young Ding
1EL 408-623-58�9
W
t� .
Z W �
W Q M
0 �
� r
� � o
::�i
W = Q�♦
� Z V
� Q Z
Z °� �
O W
0 M a '
o> >
. oo v
o� �
�
LOT
COVERAGE
&PRIVACY
PLANTING
�,a�: 05/12/14
�oe No. WHY14-0542
ISSUE&REVISION
07/02/14 LANNING REVIE
Q1 11/17/14 LANNING REVIE
12/04/14 LANNING REVIE
3
4
s
6
7
s
9
10
11
SHEET N0.
A2.0
DRAWN BY: JL
WALL LEGEND
EXISTING CONSTRUCTION TO REMAIN 12. PROVIDE ATTIC VENTILATION AS PER (2010 CRC SEC. , �ND THE
CALIFORNIA ENERGY STANDARDS COMMISSION.)
� (N)FURRED WALL/COLUMN.
13. FACTORY BUILT FIREPLACES AND FACTORY BUILT CHIMNEYS SHALL BE LISTED
-' "� NEW WOOD FRAMING WALL OUT OF 2X4 WOOD STUDS O 16"O.C. AND INSTALLED IN ACCORDANCE WITH THE TERMS OF THEIR LIST�NG AND THE
AND IN 11-IE EXTERIOR STUCCO 7/8"MIN. STUCCO 0/METAL MANUFACTURER'S INSRUCTIONS AS PER (2010 CRC SEC. R1004 AND R1005)
WOOD BURNING APPLIANCES WITHIN THE SACRAMENTO METROPOLITAN AIR
LATH 0/TWO LAYERS OF GRADE'D'BLDG.PAPER 0/ pUALITY MANAGEMENT DISTRICT(SMAQMD)NEED APPROVAL FROM SMAQMD.
PLYWOOD. (916-874-4884).
������� NEW 2X4 WOOD STUDS�i6"O.C. W/1/2" THK. GYP.BD.ON 14. PROVIDE UNDER FLOOR CLEARANCES AS PER 2010 CRC SEC110N R317. A
THE BOTH SIDES MINIMUM OF 12" CLEARANCE TO UNDER FLOOR GIRDERS AND 18" CLEARANCE
TO FLOOR JOISTS IS REQUIRED UNLESS PRESERVATIVE-TREATED WOOD OR
NEW 2X4 WOOD STUDS�16"O.C. W/1/2"THK. GYP.BD.ON WOOD NATURALLY DURABLE TO DECAY IS UTILLIZED. A MINIMUM 18-INCH BY
THE BOTH SIDES USE WONDER BD. OR DUROCK AS BACKING 24-INCH ACCESS OPENING SHALL BE PROVIDED TO THE CRAWL SPACE.
MATERIAL AND WATER PROOFED MATERIAL (2010 CRC SEC. R408.4.)
��� GARAGE COMMON INTERIOR WALL NEEDS TO BE SHEATHED NIITH 15. FIRE BLOCKING AND DRAFT STOPPING SHALL BE INSTALLED ACCORDING.
AT LEAST 1/2"THICK DRYWALL, AND THE CEILING SURFACE
REOUIRES MINIMUM 5/8" THICK�INTERIOR SIDE. (2010 CRC SEC. R302.11.)
ONE HOUR RATED EXTERIOR WALL 2X4 WOOD STUDS�16"O.C. �6. ALL GYPSUM BOARD, STUCCO, PLASTER, AND LATH SHALL BE INSTALLED.
W/7/8°STUCCO�EXTERIOR SIDE. (2010 CRC CHAPTER 7.)
S.G. SAFETY GLAZING WINDOW/TEMPERED GLASS 17. EXTERIOR wALL COVERINGS SHALL BE APPUED. (2010 CRC SEC. R703.)
F� �� 18. ALL CIMNEYS ATTACHED TO ANY APPLIANCE OR FIRELACE THAT BURNS SOLID
(�x\I CRAWL ACCESS 18"X24"MIN. (2010 CRC SEC.R408.2) FUEL SHALL BE EOUIPPED WITH AN APPROVED APARK ARRESTER.
�__�
� %'' ATT1C ACCESS 22"X30"MIN. (2010 CRC SEC. R5017) (2010 CRC R1003.9.1)
��� � A HEAD ROOM CLEAR HEIGHT IN A ATT1C AT LEAST 30° 19. FIXTURES SHALL BE SPACED IN ACCORDANCE WITH THE CALIFORNIA PLUMBING
�_��� AT THE AT11C ACCESS" CODE. (2010 CRC R307.1)
20. BATHTUB AND SHOWER FLOORS AND WALLS ABOVE BATHTUBS WITH INSTALLED
WINDOW LIGHT/VENT CAL SHOWER HEADS AND IN SHOWER COMPARTMENTS SHALL BE FINISHED WITH A
NONABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A HEIGHT
OF NOT LESS THAN 6 FEET(1829 MM)ABOVE THE FLOOR (2010 CRC R307.2)
21. SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER CONVEYANCE OR
VENTILATION UGHTING OTHER APPROVED POINT OF COLLECTION THAT DOES NOT CREATE A HAZARD.
LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM FOUNDATION
ROOM NAME AND ROOM SIZE AREA REQ'D AREA REO'D PROVIDED WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 INCHES(152 MM) WITHIN THE
LOCATION (S F) - (4i)OR -(8i)OR M�NDOW FIRST 10 FEET(3048 MM). (2010 CRC R401.3)
� 5 S.F. MIN. 10 S.F. MIN. AREA(S.F.)
NOTES TO WINDOW AND DOOR
1. PROVIDE AT LEAST ONE WINDOW IN EACH BEDROOM TO COMPLY WIITH AS
REQUIRED FOR ESCAPE OR RESCUE; REQUIRED OPENING OF MINIMUM NET
CLEAR AREA IS 5.7 S.F. MIN, (5 S.F. MIIN. IF THEY ARE WITHIN 44 INCHES
ABOVE OR BELOW GRADE, HIGHT 24 INCHES MIN., WIDTH 20 INCHES MIN.,
AND BOTTOM, CLEAR OPENING 441NCHE5 MAX. ABOVE FLOOR.
(2010 CRC SEC 310.)
2. WINDOWS WITH AN OPENING SILL HEIGHT MORE THAN 72 INCHES ABOVE GRADE
SHALL HAVE THE LOWEST PART OF THE OPENING PORTION AT LEAST 24 INCHES
ABOVE THE FINISHED FLOOR. GLAZING BETWEEN THE FLOOR AND A HEIGHT OF 24
INCHES SHALL BE FIXED AND ANY OPENINGS SHALL NOT PASS A 4 INCH SPHERE
(2010 CRC SEC R612.2).
3. OPENABLE PORTION OF NEW WINDOWS ARE TO SAl1FY THE REQUIRED
NATURAL LIGHT(S%)VENTILATION (4%).(2010 CRC SEC. R303.1)
4. SEE TITLE 24 ENERGY REPORT FOR REAL U VALUES OF WINDOW AND DOORS.
5. A PERMANENT LABEL PER CBC SEC 2406.4 SHALL IDENTIFY EACH LIGHT OF
SAFETY GLAZING.
6. THRESHOLDS AT DOORWAYS SHALL NOT EXCEED 0.75 INCHES IN HEIGHT FOR
SLIDING DOORS AND 0.5 INCHES FOR OTHER DOORS.(CBC 1008.1.7)LANDINGS MAY
BE UP TO 7 75 INCHES BELOW TOP OF THRESHOLDS IN R-2 OR R-3(CBC
1008.7.6). THIS INCLUDES A 7 INCH FINISHED FLOOR TO LANDING HEIGHT AND A
3/4 INCH THRESHOLD.
NOTES TO BUILDING
1. BRACED WALL PANELS SNALL BEGIN NO MORE THAN 8 FEET(2440 MM)FROM
EACH END OF A BTACED WALL LINE AND SHALL BE SPACED A MAXIMUM OF 25
FEET(7620 MM) ON CENTER. (2010 CRC R602.12.1.2)
2. IN R-3 AND U OCCUPANCIES, NO OPENINGS ARE ALLOWED IN WALLS 3 FEET
OR CLOSER TO PROPERTY LINE,OPENINGS IN WALLS BETWEEN 3 FEET AND UP
TO 5 FEET FROM PROPERTY LINE CAN BE UP TO 25 7 OF WALL AREA. ALL
WALLS LESS THAN 5 FEET FROM THE PROPERTY LINE MUST BE FIRE RESISTIVE
CONSTRUCTION, (2010 CRC TABLE 302.1). EAVES MUST BE PROTECTED IF ANY
PART OF THEM EXTENDS INTO THE AREA WERE OPENINGS ARE PROHIBITED.
THIS MEANS THAT AN EAVE CAN EXTEND TO A POINT 24 INCHES FROM THE
PROPERTY LINE. BUT NO CLOSER.
3. PROVIDE 2X6 �ALL PLUMBING WALL LOAD BEARING WALL AS INDICATED ON
STRUCTURE DWG.
4. PLATE WASHERS, A MINIMUN OF 0.229 INCH BY 3 INCHES BY 3 INCHES (5.8
MM BY 76 MM BY 76 MM) IN SIZE, SHALL BE PROVIDED BETWEEN THE
FOUNDATION SILL PLATE AND THE NUT EXCEPT WHERE APPROVED ANCHOR
STRAPS ARE USED. (2010 CRC R602.11.1)
5. SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER CONVEYANCE OR
OTHER APPROVED POINT OF COLLECTION THAT DOES NOT CREATE A HAZARD.
LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM FOUNDATION
WALLS THE GRADE SHALL FALL A MINIMUM OF 6 INCHES(152 MM)WITHIN THE
FIRST 10 FEET(3048MM). (2010 CRC R401 3)
6. DUCTS WITHIN PRIVATE GARAGES ARE TO BE CONSTRUCTED OF STEEL HAVING
A THICKNESS NOT LESS THAN N0. 26 GAUGE SHEET STEEL AND HAVE NO
OPENINGS INTO THE GARAGE. (2010 CRC SEC. R302.5.2)
7. HABITABLE SPACES WITNIN A DWELLING UNIT, OTHER THAN KITCHENS,SHALL
NOT BE LE55 THAN 7-FEET IN ANY DIRECTION AND HAVE A MINIMUM OF 70
SQUARE FEET OF FLOOR AREA (EXCEPT KITCHENS).
(2010 CRC SEC. R304.)
8. PROVIDE SAFETY GLAZING FOR ALL GLAZtNG LOCATED IN HAZARDOUS
LOCATIONS AS SPECIFIED IN (2010 CRC SEC R308 4.)
9. SHOWERS IN ALL OCCUPANCIES SHALL BE FINISHED WITH A NONABSORBENT
SURFACE TO A HEIGHT OF 6-FEET ABOVE THE FLOOR.
(2010 CRC SEC. R307.)
10. PROVIDE AN APPROVED ATTIC ACCESS 22"X30"WITH 30 INCHES MINIMUM
VERTICAL HEADROOM (2010 CRC SEC. R807)
11. ENCLOSED ACCESSIBLE SPACE NUDER STAIRS SHALL HAVE WALLS,
UNDER-STAIR SURFACES, AND ANY SOFFITS PROTECTED ON THE ENCLOSE SIDE
WITH 1/2 INCH GYPSUM BOARD. (2010 CRC SEC. R302.7)
GARAGE NOTES
1 GARAGE COMMON INTERIOR wALL NEEDS TO BE SHEATHED WITH AT LEAST
1/2° THICK DRYWALL, AND THE CEILING SURFACE REQUIRES MINIMUM 5/8"
THICK�INTERIOR S�DE.
2. ONE HOUR RATED EXTERIOR WALL 2X4 WOOD STUDS�16" O.C. W/7/8"
STUCCO�EXTERIOR S�DE.
3. ALL DRYWALL SEAMS MUST BE TAPED/FINISHED WITH JOINT COMPOUND
AND SOME JURISDICTIONS MIGHT REQUtRE FIRE RATED JOINT TAPE FOR THIS
PURPOSE.
4. THE GARAGE FIRE WALL SHOULD HAVE NO MISSING/DAMAGED DRYWALL
SECTIONS,ANY PENETRATION MUST BE SEALED (FIRE RATED CAULKING
WOULD BE PERFECT FOR SMALL GAPS AROUND THE PIPES, AIR DUCTS,
DOOR FRAMES, ECT).
5. ENTRY DOORS FROM �l-1E GARAGE INTO THE HOUSE AT LEAST 20 MINUTE
FIRE RESISTANCE RA7ED OR 1 3/8" SOLID CORE DOORS.
6. DOORS REOUIRE PROPER WEATHER STRIPPING TO CREATE AN AIR TIGHT
BARRIER BETWEEN THE GARAGE AND A LIVING QUARTERS.
7. THERE SHOULD BE NO OPENINGS BETWEEN THE GARAGE AND ROOMS USED
FOR SLEEPING PURPOSES.
8. A FORCED AIR HEATING SYSYEM DISTRIBUTING AIR THROUNGH THE HOUSE
WI1H A REGISTER(SUPPLY OR RETURN)OPEN IN THE GARAGE. THE AIR
DUCT OPENING SEALED WITH SHEET METAL AND FIRE RATED CAULKiNG.
METAL AIR DUCTS EXPOSED IN THE GARAGE AREA SHOULD BE AT LEAST 26
GA. STEEI,NO PLAS�IC OR ALUMINUM (THIN WALL OR FLEXIBLE TYPE)VENT
HOSES PENETRATING THE SEPARATION WALLS ARE PERMITTED - IF THERE'S
NO OTHER WAY TO RUN THOSE VENT PIPES, INSULATE IT, BOX IT OUT AND
FINISH IT WITH 5/8 DRYWALL(TYPE X, TAPED)
9. GARAGE FLOOR MUST BE NON-COMBUSTIBLE MATERIAL AND SLOPED
TOwARDS THE FLOOR DRAIN OR OVERHEAD DOORS
10. ATTIC ACCE55 INSTALLED IN THE GARAGE. THE GARAGE FIRE WALL/
HOUSE SEPARATION WALL SHOULD EXTEND ALL THE WAY TO THE ROOF
DECKING OR GARAGE SECTION SHOULD HAVE A 5/B"DRYWALL CEILING
INSTALLED.
11. GARAGE RECEPTACLE OUTLETS SHALL BE AT LEAST 18"ABOVE THE FLOOR.
5�. .. �
N
3i
o,
°z'
3
z
�1
A+B+C+D+E+F=1,202S.F.
18+424+514+1+49+185=1,202S.F.
G+H=443S.F.
GARAGE 6+437=443 S.F.
_
3
w
J
z
a
�
z
� �
N +6 G,
ti
iv l��`\j-��Q
O�� �
� �
� ���� 3
I °Za� �
0
co �oww z
z�� 3
�
o T!y-�O•.
i F FO -1-
N. �A!�sn
i <.
I �
� � I
i � �
�n I �
I �
��J
�
o ���
I °zd
i� �o w
Z J H
.�N
16'-7"
(N)5'0"X4'0"
_ SLIDING
J � x � L_ �N)
I REF
I
�
I
I
I
)t� �N) KITCHEN
� TILE
UP
__10'��..._ ____..
�.....:..`.........:...:...:.:
(N)8'0"X6'8"
TEMP. GL.
SLIDING DR.
�N) FAMILY RM.
HDWD
�
i N NOOK
i HDWD (N) PANTRY
I HDWD
I
i---------------- N LAU.
I TILE
L_- (N)W II��
TI
��x��� (N RYER
I����I� 'O'
N COAT
(N)W.H.
� DINiNG RM. Howo � ' �
HDWD 2R �Ni LANDING
N POWDER corvc. s�ne
TILE�
O'•�
� +6.
's c
�,.c
m�i.
�N) LIVING RM.
HDWD
1,202 SF N Hs�AiR
(N)
5'0"X6'8"
fr\ DR. /
+6' , `� ` �
O
�N�6.0„XS,o.. ,��o� ': N.:r�,�� ._
SLIDING/S.G. F�+�Q : CON6. SLltB "
TEMP. GL
EGRESS � .:�;�
2R
50 SF
6'-11° 2.-0., .,-6' 6'-2.' ._6
� �
�•: r ',,- _�;
` � -�'��._�.�.
;. x
_... .,.- •--.Y.�
,�q .. . .- '�1►4z.w. -. �+.'rwwtfo_^e ^y�y�y�
!
�!s�� f '.�� t��.r:�. :;,
, , .
'�� `, i_ � 'i ..,- ��,`�.,.. �._a......�.-.�,..,..�....d.,......,,.,,,,,.,,,=
,,�a .,_ -...,�„-.`., .:,� �
�
f����t ��.�..�
� F,Ja s p '
. ....e: . � .
.. . ..
�f�� r�ry .... ..w<.
,� - �
14"-0.'
UP
2R
�:
.N................ �' ..:
�.............<
(N)5'0"X6'8"
TEMP. GL.
SLIDING DR.
(N) BEDROOM �1
HDWD
0
i
�
(N) BATH �1
TILE
�SHWR�
V.I.C. �-� o c�
� � \ /\ �viJ
\/ x\�
/\ o Z a
--- /// \\\ � � ���
?,cJn
I
(N) 2 CAR GARAGE o �
' CONC. SLAB x z
a�
442 SF Z
(N) 16'0"X7'0" GARAGE DOOR �
i
�
'v
19'-4.'
PROPOSED 1 ST FLOOR PLAN
SCALE: t/4"= 1'-0"
�
� A
WHY
Constuction
DESIGNER
Jack Lin CSLB�964820
6805 Westmoor Way
San Jose,CA 95129
TEL: (408) 218-0587
Emoil: fu333�yahoo.com
NI keoe,deagie,arrvngmmenle k plana
dicoled or npr�untad by fhw Erawmg
o.�.a er.a�d�n��.,a..ry oi
MBYCO�MI1OCIfON
aoe.�. .�oi<a,��Ka a�a xK+w�a
ro�use ma�n ne�an.ro�,
the epx�ified projttt� Noirc of eucA
idem.desi9ns.afonqemenls a da+a
aholl be uud b`a dscloxd lo any
ve�no�.n�o,omorouo�,ia o�Y
��oe�.natsoe.x nnwi m<
�n«���.��o�m
w'BYCtlMIfOCIlI1M
ai��ro�au���.<o ee.Y.m.e er di
P.+,o�:.oa,�pao��:onC proFCt
prcxntativea Ma�vll ulilitY Mae.
ShoWd any erra,canflicl w ncineleTmcy
appear n Ne ba�ng+,Nb aK�e u t
n��onr a ro.n:o-��t�.o.a,to
o.00«emy.rtn a�y�o�s��,ce�o�.
OWNER:
MR. Bao Ding
TEL: 408-828-9808
EMAIL: ghifeng�yahoo.com
MR. Young Ding
1EL: 408-623-5809
W
V
Z
W
�
�
�
�
�
�
�
�
�
■
�
�
■
W
Q
�
�
QT
i
L�
�
�
�
�M
W
�
o�
�
�
M
r
�
::�i
�
Q
V
Z
�
�
W
�
V
PROPOSED
1ST
FLOOR PLAN
�A�: 05/12/14
�oa No. WHY14-0542
I ISSUE&REVISION
12/04/14
SHEET N0.
A2.1
DRAWN BY: J�
WALL LEGEND
_..............._._......_..
EXISTING CONSTRUCTION TO REMAIN
� (N)FURRED WALL/COLUMN.
NEW WOOD FRAMING WALL OUT OF 2X4 WOOD STUDS O 16"O.C.
AND IN THE EXTERIOR S1l.1CC0 7/8"MIN. STUCCO 0/METAL
LATH 0/TWO LAYERS OF GRADE'D'BLDG. PAPER 0/
PLYWOOD.
������� NEW 2X4 WOOD STUDS m 16"O.C.W/1/2"THK. GYP. BD. ON
1HE BOTH SIDES
NEW 2X4 WOOD STUDS O 16"O.C.W/1/2"THK. GYP. BD. ON
THE BOTH SIDES USE WONDER BD.OR DUROCK AS BACKING
MATERIAL AND WATER PROOFED MATERIAL.
��� GARAGE COMMON INTERIOR WALL NEEDS TO BE SHEATHED WITH
AT LEAST 1/2'THICK DRYWALL, AND THE CEILING SURFACE
REOUIRES MINIMUM 5/8"THICK O INTERIOR SIDE.
ONE HOUR RATED EXTERIOR WALL 2X4 WOOD STUDS O 16" O.C.
W/7/8"STUCCO m EXIERIOR SIDE.
S.G. SAFETY GLAZING WINDOW/TEMPERED GLASS
F��'I
I x I CRAWL ACCESS 18°X24"MIN. (2010 CRC SEC.R408.2)
����
� %'' ATT1C ACCESS 22"X30"MIN. (2010 CRC SEC.R5017)
��` � A HEAD ROOM CLEAR HEIGHT IN A AT11C AT LEAST 30"
�__�., AT THE AT11C ACCESS"
WINDOW LIGHT/VENT CAL
VENTILATION LIGHTING
ROOM NAME AND ROOM SIZE AREA REQ'D AREA REQ'D PROVIDED
LOCATION (S.F.) -�4%)OR -(87)OR �NDOW
5 S.F. MIN. 10 S.F. MIN. AREA(S.F.)
NOTES TO WINDOW AND DOOR
1. PROVIDE AT LEAST ONE WINDOW IN EACH BEDROOM TO COMPLY WIITH AS
REQUIRED FOR ESCAPE OR RESCUE; REQUIRED OPENING OF MINIMUM NET
CLEAR AREA IS 5.7 S.F. MIN.,(5 S.F. MIIN. IF THEY ARE WITHIN 44 INCHES
ABOVE OR BELOW GRADE, HIGHT 24 INCHES MIN., WIDTH 20 INCHES MIN.,
AND BOTTOM,CLEAR OPENING 44 INCHES MAX. ABOVE FLOOR.
(2010 CRC SEC 310.)
2. WINDOWS WITH AN OPENING SILL HEIGHT MORE THAN 72 INCHES ABOVE GRADE
SHALL HAVE THE LOWEST PART Of'THE OPENING PORTION AT LEAST 24 INCHES
ABOVE THE FINISHED FLOOR. GLAZING BETWEEN THE FLOOR AND A HEIGHT OF 24
INCHES SHALL BE FIXED AND ANY OPENINGS SHALL NOT PASS A 4 INCH SPHERE
(2oio cRC sEC Rsiz z).
3. OPENABLE PORTION OF NEW WINDOWS ARE TO SATIFY THE REQUIRED
NATURAL LIGHT(8%)VENTILATION(47). (2010 CRC SEC. R303.1)
4. SEE TITLE 24 ENERGY REPORT FOR REAL U VALUES OF WINDOW AND DOORS.
5 A PERMANENT LABEL PER CBC SEC. 2406.4 SHALL IDENTIFY EACH LIGHT OF
SAFETY GLAZING.
6. THRESHOLDS AT DOORWAYS SHALL NOT EXCEED 0.75 INCHES IN HEIGHT FOR
SLIDING DOORS AND 0.5 INCHES FOR OTHER DOORS.(CBC 1008.1 7)LANDINGS MAY
BE UP TO 7.75 INCHES BELOW TOP OF THRESHOLDS IN R-2 OR R-3(CBC
1006.1.6). THIS INCIUDES A 7 INCH FINISHED FLOOR TO LANDING HEIGHT AND A
3/4 INCH THRESHOLD.
NOTES TO BUILDING
1. BRACED WALL PANELS SHALL BEGIN NO MORE THAN 8 FEET(2440 MM)FROM
EACH END OF A BTACED WALL LINE AND SHALL BE SPACED A MAXIMUM OF 25
FEET(7620 MM)ON CENTER.(2010 CRC R602.12.1.2)
2. IN R-3 AND U OCCUPANGES,NO OPENINGS ARE AL�OWED IN WALLS 3 FEET
OR CLOSER TO PROPERTY LINE,OPENINGS IN WALLS BETWEEN 3 FEET AND UP
TO 5 FEET FROM PROPERTY LINE CAN BE UP TO 25%OF WALL AREA. ALL
WALLS LESS THAN 5 FEET FROM THE PROPERTY LINE MUST BE FIRE RESISTIVE
CONSTRUCTION, (2010 CRC TABLE 302.1). EAVES MUST BE PROTECTED IF ANY
PART Of THEM EXTENDS INTO THE AREA WERE OPENINGS ARE PROHIBtTED.
THIS MEANS THAT AN EAVE CAN EXTEND TO A POINT 24 INCHES FROM THE
PROPERTY LINE,BUT NO CLOSER.
3. PROVIDE 2X6�ALL PLUMBING WALL LOAD BEARING WALL AS INDICATED ON
STRUCTURE DWG.
4. PLATE WASHERS,A MINIMUN OF 0.229 INCH BY 3 INCHES BY 3 INCHES (5.8
MM BY 76 MM BY 76 MM) IN SIZE.SHALL BE PROVIDED BETWEEN THE
FOUNDATION SILL PLATE AND THE NUT EXCEPT WHERE APPROVED ANCHOR
STRAPS ARE USED. (2010 CRC R602.11.1)
5. SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER CONVEYANCE OR
OTHER APPROVED POINT OF COLLECTiON THAT DOES NOT CREA7E A HAZARD.
LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM FOUNDATION
WALLS THE GRADE SHALL FALL A MINIMUM OF 6 INCHES(152 MM)WITHIN THE
FIRST 10 FEET(3048MM). (2010 CRC R401.3)
6. DUCTS WITHIN PR�VATE GARAGES ARE TO BE CONSTRUCTED OF STEEL HAVING
A THICKNESS NOT LESS THAN N0. 26 GAUGE SHEET STEEL AND HAVE NO
OPENINGS INTO THE GARAGE.(2010 CRC SEC R302.5.2)
7. HABITABLE SPACES WITNIN A DWELLING UNIT,OTHER THAN KITCHENS, SHALL
NOT BE LESS THAN 7-FEET IN ANY DIRECTION AND HAVE A MINIMUM OF 70
SQUARE FEET OF FLOOR AREA(EXCEPT KITCHENS).
(2010 CRC SEC.R304.)
8. PROVIDE SAFETY GLAZING FOR ALL GLAZING LOCATED IN HAZARDOUS
LOCATIONS AS SPECIFIED IN. (2010 CRC SEC. R308.4.)
9. SHOWERS IN ALL OCCUPANCIES SHALL BE FINISHED WITH A NONABSORBENT
SURFACE TO A HEIGHT OF 6-FEET ABOVE THE FLOOR.
(2010 CRC SEC.R307)
10. PROVIDE AN APPROVED ATTIC ACCESS 22"X30" WITH 30 INCHES MINIMUM
VERTICAL HEADROOM (2010 CRC SEC R807.)
11. ENCLOSED ACCESSIBLE SPACE NUDER STAIRS SHALL HAVE WALLS,
UNDER-STAIR SURFACES, AND ANY SOFFITS PROTECTED ON THE ENCLOSE SIDE
WITH i/2 INCH GYPSUM BOARD. (2010 CRC SEC. R302 7)
12 PROVIDE ATTIC VENTIL/+TION AS PER (2010 CRC SEC n , AND THE
CALIFORNIA ENERGY STANDARDS COMMISSION)
13. FACTORY BUILT FIREPLACES AND FACTORY BUILT CHIMNEYS SHALL BE LISTED
AND INSTALLED IN ACCORDANCE WITH THE TERMS OF THEIR LISTING AND THE
MANUFACTURER'S INSRUCTIONS AS PER(2010 CRC SEC. R1004 AND R1005.)
WOOD BURNING APPLIANCES WITHIN THE SACRAMENTO METROPOLITAN AIR
OUALITY MANAGEMENT DISTRICT(SMAQMD) NEED APPROVAL FROM SMAQMD
(916-874-4884).
14. PROVIDE UNDER FLOOR CLEARANCES AS PER 2010 CRC SECTION R317. A
MINIMUM OF 12°CLEARANCE TO UNDER FLOOR GIRDERS AND 18" CLEARANCE
TO FLOOR JOISTS IS REQUIRED UNLE55 PRESERVATIVE-TREATED WOOD OR
WOOD NATURALLY DURABLE TO DECAY tS UTILLIZED. A MINIMUM 18-INCH BY
24-INCH ACCESS OPENING SHALL BE PROVIDED TO THE CRAWL SPACE.
(2010 CRC SEC. R408.4.)
15. FIRE BLOCKING AND DRAFT STOPPING SHALL BE INSTALLED ACCORDING.
(2010 CRC SEC R302.11.)
16. ALL GYPSUM BOARD, STUCCO, PLASTER, AND LATH SHALL BE INSTALLED.
(2010 CRC CHAPTER 7.)
17. EXTERIOR WALL COVERINGS SHALL BE APPLIED. (2010 CRC SEC. R703.)
18. ALL CIMNEYS ATTACHED TO ANY APPUANCE OR FIRELACE THAT BURNS SOLID
FUEL SHALL BE EOUIPPED WITH AN APPROVED APARK ARRESTER.
(2010 CRC R1003.9.1)
19. FIXTURES SHALL BE SPACED IN ACCORDANCE WITH THE CALIFORNIA PLUMBING
CODE. (2010 CRC R307.1)
20. BATHTUB AND SHOWER FLOORS AND WALLS ABOVE BATHTUBS WITH INSTALLED
SHOWER HEADS AND IN SHOWER COMPARTMENTS SHALL BE FINISHED WITH A
NONABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A HEIGHT
OF NOT LESS THAN 6 FEET(1829 MM) ABOVE 1}-IE FLOOR. (2010 CRC R307.2)
21. SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER CONVEYANCE OR
OTHER APPROVED POINT OF COLLECTION THAT DOES NOT CREATE A HAZARD
LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM FOUNDATION
WALLS. THE GRADE SHALL FALL A MINIMUM OF 6�NCHES(152 MMj WITHIN THE
FIRST 10 FEET(3048 MM). (2010 CRC R401.3)
GARAGE NOTES
1. GARAGE COMMON INTERIOR WALL NEEDS TO BE SHEATHED WITH AT LEAST
1/2°THICK DRYWALL, AND THE CEILING SURFACE REQUIRES MINIMUM 5/8"
THICK�INTERIOR SIDE.
2. ONE HOUR RATE�ExTERIOR WALL 2X4 WOOD STUDS�16"O.C. W/7/8"
STUCCO�EXTERIOR SIDE.
3. ALL DRYWALL SEAMS MUST BE TAPED/FINISHED WITH JOINT COMPOUND
AND SOME JURISDICl10NS MIGHT REQUIRE FIRE RATED JOINT TAPE FOR THIS
PURPOSE.
4. THE GARAGE FIRE WALL SHOULD HAVE NO MISSING/DAMAGED DRYWALL
SEC�IONS,ANY PENETRATION MUST BE SEALED (FIRE RATED CAULKING
WOULD BE PERFECT FOR SMALL GAPS AROUND THE PIPES, AIR DUCTS,
DOOR FRAMES, ECT).
5. ENTRY DOORS FROM THE GARAGE INTO 7}-IE HOUSE AT LEAST 20 MINUTE
FIRE RESISTANCE RATED OR 1 3/8" SOLID CORE DOORS.
6. DOORS REQUIRE PROPER WEATHER STRIPPING TO CREATE AN AIR TIGHT
BARRIER BETWEEN THE GARAGE AND A LIVING QUARIERS
7 THERE SHOULD BE NO OPENINGS BETWEEN THE GARAGE AND ROOMS USED
FOR SLEEPING PURPOSES.
8. A FORCED AIR HEAl1NG SYSYEM DISTRIBUTING AIR THROUNGH THE HOUSE
WITH A REGISTER(SUPPLY OR RETURN) OPEN IN THE GARAGE. THE AIR
DUCT OPENING SEALED WITH SHEET METAL AND FIRE RATED CAULKING.
METAL AIR DUCTS EXPOSED IN THE GARAGE AREA SHOU�D BE AT LEAST 26
GA. STEEL, NO PLASTIC OR ALUMINUM (THIN WALL OR FLEXIBLE TYPE)VENT
HOSES PENETRATING THE SEPARATION WALLS ARE PERMITTED - IF THERE'S
NO OTHER WAY TO RUN THOSE VENT PIPES, INSU�ATE IT, BOX IT OUT AND
FINISH IT WITH 5/8 DRYWALL(TYPE X, TAPED)
9. GARAGE FLOOR MUST BE NON-COMBUSTIBLE MATERIAL AND SLOPED
TOwARDS THE FLOOR DRAIN OR OVERHEAD DOORS.
10. ATT1C ACCESS INSTALLED IN THE GARAGE. THE GARAGE FIRE WALL/
HOUSE SEPARATION WALL SHOULD EXTEND ALL THE WAY TO THE ROOF
DECKING OR GARAGE SECTION SHOULD HAVE A 5/8"DRYWALL CEILING
INSTALLED.
11. GARAGE RECEPTACLE OUTLETS SHALL BE A7 LEAST 18"ABOVE THE FLOOR.
�
21'-0" Q .
(N)WINDOWSILL
1 3'-4"
1 S.-2.'
21' 0"
536+185+41=762 S.F.
�
O
I
�
O�
�
X�
. Z
�o
z�
��
I
�
�
i
in
0
y(.�N
xZW
i o��
�I �ui w
Z
N
i�
, �P � '�'��-.�
. . . :_...,_....�,........,...-,..�,.,,.,. ..a.ww....w..:_.,....�,.......�.,......M..�,..o
t
i �i, �( "`
4 ...� i f�.tiY:4����'
,,. ..N..,_.. .,. ,.,... . -�>,.»...,...,..�...W........,.........._
�4'^ .� .-'} �": /r'C�-J�. /�
(
. .- ......,.,�.- . ._.. ;+.........T,. ......�.-.....�,
,:,� _,.
�r „ ., .,t �.�.*'rr4 a.=
¢.�'? s f `.,L V
.. .F.. � �n..�.�.r y.�..d>+.�..cn
3,_6.. 4._8,. 2,_4., 3,_4„ 3,_4,. 2._4„ �._9..
(N)5'�X6'0��
SLIDIN /S.G.
�
� TEM GL ,��J
0 5��, G S T�+F:
(N)30"X3'0° �1�' Q. �''O�
SLIDI G/S.G. `F` �
TE P. GL. WINDOWSILL
M. ATH
� T1LE
r___--_ -_-�
� �
� I I
I I
i (N) M. BEDROOM i
� � HDWD �
� � �
I I
I I
� L-------- -J
�-------
i N M.W.I.C.
� HDWD
�
L -
fN) LOUNGE
HDWD
762 SF
�- --,
I I
� �
��) BEDROOM �3i
I HDWD I
� �
I I
_J
� N----
HDWD
N BAT 2 �SHWR�
TILE �y\ ��
�---a \/
I\ /I /\
� \ /� � �/-\i
� � � � �-'�
L_��_J � �
�-------�
I
I I
I I
(ND BEDROOM �2i
N STAIR i How� i
HDWD I I
I I
(N)2'o"xs'o" io L__ __J
SLIDING/S.G. Ulo
TEMP. GL z I x
(N)5'0"XS'0"
SLIDING
EGRESS
2�-10" � 4'-10" � 2'-il" � 10'-5..
�
O�J
N �
X�� �
�
o z� o,
in Q
vJlW-
�
I
N
o�
�J
X�� �
o Z� �
^0� N
VJ F-
�
PROPOSED 2ND FLOOR PLAN
SCALE: i/4"= 1�-0"
z`�
A
� A
WHY
Constuction
DESIGNER
Jack Lin CSLB �964820
6805 Westmoor Way
San Jose.CA 95129
TEL: (408) 218-0587
Email: fu333�yahoo.com
^�dsas.%.eq�a.m.mge.nenta s pm.
dicolM rapnawilW by lhia traring
matl by,antl fhe prapwlY of
���carraon�
a t.aT��«�a x.�op.a
ea�Y�ww� a o.��
n.+a��n.a o a�i No,.« n
ao.,w�y�.. v«o«�i. P�m.
nan w .a cr o.a�xio.w eo y
o�,�,.�a��:����.a�Y
p��o.�.noe.oe... �eno�<�n�
•ritten D��seicn ol
M�Y CIIflWN.TRN
ui„rm.�ou«�i.�o e.K.re.e ey ai
pwema.carpanin md propct
reprexn�olires N<��il ula�ln nai
S�hould y ma. sict etm<y
ppear m N<barinq,t�ie olfice murt
De notMbA�o�hrtruc[Ime o�or m
praeeEln9 M�n mY conatrucllm.
ON?JER:
MR. Bao Ding
TEL: 408-828-9808
EMAIL: ghifeng�yahoo.com
MR. Young Ding
TEL: 408-623-5809
�
V
�
W
�
�
�
W
�
�
�
�
�
■
�
�
W
Q
�
�
a
_
Z
�
Q
�
�
�M
W
r
�
�
�
M
�
r
�,A
/r�I
VI
a
V
O
Z
i
�
:�.�
�
�.i
PROPOSED
2ND
FLOOR PLAN
DA�: 05/12/14
�oa No. WHY14-0542
ISSUE&REVISION
12/01/14
SHEET N0.
A2.2
DRAWN BY: JL
0
I
N
� 28'MAX. HEIGHT I
----------------------'--------------
I PROPERTY L�NE ' WALL PAINT KELLY-MOORE KM3502-2 PROPERTY LINE I
I MOUDLING&TRIM KELLY-MOORE KM3452-2 �
" TWO LAYERS OF 15#FELT FOR ROOF
CEM. TILES
STUCCO WALL
_ TOP
2ND FL.
2ND FL. SUBFLOOR I
o °
i I iST FL.
o TOP OF PLATE
N
-(N)CHIMNEY �\
/� o 'i \
i �
/ "� ° \
� � � I �
/ ih �
/ o ,'1 II o \
/ I I �
� � � \
� . , . — ., . I . I _- �
. . . i � �. �, . �
���i . ��H-.., — _��'————� � ���� �- �—I—J \
—
- - - -
v�
T P F RI ao
�
I �
2ND FL. `�
TOP OF PLATE
�
I
m
�
FL SUBFLOOR i
o �
GARAGE � N
TOP OF PLATE
I
� --i
� �; �
o � �
�' _ � LJ� �� � v� `� � 18930 � I
` , I,� e , � � ,_----- - -.
I �J, JI� ` iT �
(N1 FFNr o a � a� �—'�� � i '�.._
(N)FEN_CE�
I I o i �E
u � � J�_F I`��'i !�i li � F __ � �I I�- I � .
h LJ !�— �I���� .
�I ''� � I I o
. , �,n -
. r, � I
i �d; .i �I���� - — -
i
—�i ��^ o
�
o i — — JI�
,II�—
� i�
i
I
� I! -
- i
�I I
- — , cD
O
io o � ��i�' '�� � �� II ��I �
� �i
, �I I
. -. ,., . I���--�� �,�, `=s°
--- ��=------ � 1SUBFLOOR N o -o�=!�,o- o '�` - _/I li ° i�I rrJl�=� �ti�q,_E �,�;, I ��' I
O O O I �L�__-�I.____, 'II i
cO (N)LANDING �CURB LINE �THE NATURA�(EXISTING)GRADE LINE
FOUNDATIONVENTN0.01-N0.04 "CRAWL SPACE VENTS DO NOT 'PROVIDE WEEP SCREED AT FOUNDATION PLATE LINE ON ALL STUCCO WALLS(2013 CRC SEC. R 703.6.2.1)
OCCUR IN SHEAR WALLS. WEEP SCREED SHALL BE 4"ABOVE EARTH AND 2" ABOVE PAVED AREA.
NOTES
' WOOD SUPPORTED BY EXTERIOR FOUNDATION
WALLS. WOOD FRAMING MEMBERS, INCLUDING WOOD
SHEATHING, THAT REST ON EXTERIOR FOUNDATION
WALLS AND ARE LE55 THAN 8 INCHES(203 MM)
FROM EXPOSED EARTH SHALL BE OF NATURALLY
DURABLE OR PRESERVAl1VE-TREATED WOOD.
* EXCEPTION. [DSA-SS&OSHPD 1,2 AND 4]AT
EX7ERIOR WALLS WHERE THE EARTH IS PAVED WITH
AN ASPHALT OR CONCRETE SLAB AT LEAST 18
INCHES(457 MM)WIDE AND DRAINING AWAY FROM
THE BUILDING, THE BOTTOM OF SILLS ARE PERMITTED
TO BE 6 INCHES(152 MM ) ABOVE THE TOP OF
SUCH SLAB. OTHER EQUIVALENT MEANS OF TERMITE
AND DECAY PROTECTION MAY BE ACCEPTED BY THE
ENFORCEMENT AGENCY.
(CBC 2304.11.2.2)
� —__-----_—_�____ 28� MAX. HEIGHT _____�_______
I PROPERTY LINE ' WALL PAINT KELLY-MOORE KM3502-2 PROPERTY LINE
I MOUDLING&TRIM KELLY-MOORE KM3452-2
�i •TWO LAYERS OF 15#fELT FOR ROOF
� CEM. TILES
STUCCO WALL
�
I =-.-i
o I ,
� 2ND FL. ' I
^ TOP OF PLATE PROPERTY LINE
0
1' il
� I r�-�i �'.n
- ��� '� �
\�� �I�I I�iil � I �a - - ���
—�n �'=��..J �I'I ��i'..
io Ir �I ��'�'�I�',�.�,.I 'I—�� —
I ���II���, Lu��L—J .� I I ,�I�— .I�`
'o n�l IJ n i I I I' I
�C I�� '� �I� ��'�—
I^ I�—�I�
� ILJ� '�I'�; �.'�I� �,,�'�,�—
„ —��—
�._,,rt� ,,.r �', —
,_.. ..�� , �I��ii. .i- -
— 0--O_,-,=0,— O— _ �I ,I� 'II� f,I�,- �_G.
I N
i
�
I �
� "�
TOP OF RIDGE _,
_ r'� (N)CHIMNEY
'o
� � I
�'I
\
o .
' i \ I o
o I / .
i � ,� _�
� � rn
m
/ �
\
/ � ii, , , o I \
/ . . . `n � . � �`'-lr o .
° I � �_�,=u_� �i _i , i � _i
0
i 2ND FL SUBFLOOR / � �I;� <v � _I'<'E �
�-, o - - _- - ---- ------ =� i' i _ �
�' i GARAGE �: i
TOP OF PLATE TOP OF PLATE o
N
':�� � �s;�l�,�.3��
. ♦� ..'' � . ...,,�...,�,..,.�.�....r+�.�.....sy..,,.�.....or..�...��.��.s.....o.�....r,n
"�,5 �
, l�R' �y�;
.�;�.r� �E �f�t °�,,,, �
`��;{)�f`f �.J� ;i d�j..t ._._n . .»w�c..���,.�.��. �.�rw-uv.�...�.a�w.
i .�i!,«3�., er '+,'�'
- +��B�I��,�'3�,,' 3'.-�..-....� .._ ..... - i ...r.� . . ..u. .r�.w.....w�.�.�.ar
(���'::��F�f���`�Y `
� � � o
� ` ��'' y-'; � FENCE I
N FENCE _ v
- a .
� )
.
. -i o
F - r�� �=. -_
�
i
<o Jr.,- �;.G� .�. ° ,�-- - �
o �
o � �
I _I _,.i.T: .I
� I a I c�
� �, p �r�� '� ' �i i li .. I�:� 1ST FL.
I =- - ----- --- -- ------ SUBFLOOR
O -- O ---- � O O O
——————— ——————--———————— " :
THE NATURAL(EXISTING)GRADE LINE� CURB LINE� (N)LANDING -�
FOUNDATIONVENTN0.07-N0.10 *CRAWL SPACE VENTS DO NOT "PROVIDE WEEP SCREED AT FOUNDATION PLATE LINE ON ALL STUCCO WALLS(2010 CRC SEC. R 703.6.2.1)
OCCUR IN SHEAR wALLS. WEEP SCREED SHALL BE 4" ABOVE EARTH AND 2" ABOVE PAVED AREA.
0
1 NORTH ELEVATION
,i4•-,�-o-
ZSOUTH ELEVATION
,�4•=,.-o�
WHY
Constuction
DESIGNER
Jack Lin CSLB#964820
6805 Westmoor Way
San Jose,CA 95129
TEL: (408) 218-0587
Email: fu333�yahoo.com
Ni dro,.e�y�..>.�y�,���.s pm�.
me��o�.a o.,.�.mew nr an e,�.my
omM br,and the prapMy of
M 9 Y CQMRUCII[N
aoa.� �mc.e,�.dKe,�a a�K+ev�e
ro�� a„ �ctb�.ro�,
tne�e��rKa o.o��no�.oi d,
�aao�.e�qns. y�.�ta o po�e
.nan n��cee�ey o dwosed to w�r
peram.firm rpora[im ta my
�urpoae+haleoewr nMWI the
'tlm pamiwim of
N 9 YCQRI�UC11fM
ui�+o.mo+w��.e x m a ey ai
<e„o�a�«�va��o a P x c
crcK�tan.en m t n tunr mex.
sno�ie o�y�..« �n�Kt o�����e�si e�r
ppw n the bvwnye,lhie oNcv mu t
be notifkd tar nsW<lions prdr to
o.00«a��y.ro,a,y�o�.�ti<e�o�.
OWNER:
MR. Bao Ding
TE�: 408-828-9808
EMAIL: ghifeng�yahoo.com
MR. Young Ding
TEL: 408-623-5809
W
� •
Z W �
W Q M
o '
N �
� � o
�
W = Q
� z �
(' Q z
Z m o�c
O W
Q M a
� '
■ � �
� r
�
II ELEVATIONS I
�A�: 05/12/14
�oe No. WHY14-0542
ISSUE&REVISION
07/02/14 LANNING REVIE
01 11/17/14 LANNING REVIE
12/04/14 LANNING REVIE
SHEET N0.
A3.1
DRAWN BY: JL
0
28'MAX. HEIGHT
__________�__�_________/__��___�—____��_��__�______�_________________
I PROPERTY LINE � ' WALL PAINT KELLY-MOORE KM3502-2 � PROPERTY LINE I
N I � MOUDLING &TRIM KELLY-MOORE KM3452-2 � \ I N
� "TWO LAYERS OF 15�j FELT FOR ROOF �
� CEM. TILES � � a
TOP OF RIDGE STUCCO WALL � � TOP OF RIDGE
mTOP OF RI T.I' i� � -�--.��---r- \ `�
�`r` T-?' '-'--�-- -' \ � TOP OF RIDGE �
i� / � -`� � =r,�-- ..---�- ' �� �.�-�-�-- _-I. .� . �..r�___, \
`� 2ND FL. I / / .--'-,� ��� _i�--�r- - �--w�r. ---�-�--.- -�- ;�T - � 2ND FL. i
TOP OF PLATE / \ TOP OF PLATE
/
\
/
i
\
/ o �
I � ;•� 'o � � �
� i o _
o I / ''u� i \ I o
i ---J
_ . i
�
�
� �
� / � O �
�
/ � M �
/ — _J
�
pI � ��T!-��.�r�—I,-r-�—� � � �-�.T- �'�,L�. � \ � I Oj O
j _ 2ND FL. SUBFLOOR / ^`�--�����-`�-T'-�r- -r' ��—,- �-���-r`rT, F,,-= � �v \ 2ND FL SUBFLOOR i
�� 1
� o - �-��_ � , i--�--=r-�.=�� rr�- - � ^o �
I---r- ,------,--r - 1 ST FL.
N
I - N I
o T P F P AT
0 0 L E
P A
N TO OF PL TE o
O N
� � _ �,.��. ���' '� �* `�i:�'—��I, I'��'�..o �II Ji. � �
�j i� � � I I� I �" � --------_---- — — ----- �E)FENCE� o
�-_ �F
�, I � `D �ti� II o w.F � � —
m
�
ii�i ° � .
� � o
-
i� 'v> �
� . �
0 0
I
i ,
1
ST FL
I �I � � .
�.-
. _ �_ �J_
F
15T L
I
�
-------
SUBFLOOR , �
� �
SUBFLOOR
d o 0 0
I r
.
� THE NATURAL(EXISTING)GRADE LINE (N)LANDIN (N)LANDIN (N)LANDING �
FOUNDATIONVENTN0.11-�10.15 •CRAWL SPACE VENTS DO NOT *PROVIDE WEEP SCREED AT FOUNDATION PLATE LINE ON ALL STUCCO WALLS(2010 CRC SEC. R 703.6.2.1)
OCCUR IN SHEAR WALLS. WEEP SCREED SHALL BE 4" ABOVE EARTH AND 2"ABOVE PAVED AREA.
1 WEST ELEVATION
,i4-=,�-o•
� , . n
. � /�-�>I�-3�
� , u� . �V.f,.. . � ....
,, .¢ � ,. �, .r__ ... -
.,. , '.t.,�,-����>._
r a � _� � : - r ,��. -:..;:__.�.�..��,...o,.,..d.........
���;�,�t . <.r. ' �'S�'�� .,/, � ...,�L;.:,..,:-.
�S�.E Fr,� , s.. .�,. ,�,,,,��„�,� �
`-..sl�e..�!i��'�;�
, I't^ ' 28' MAX. HEIGHT
�,ur�a' �,4��i:i�nr, r�
�----�----------- ----------------------------------------------------
PROPERTY LINE *WALL PAINT KELLY-MOORE KM3502-2 PROPERTY LINE I
N I +TWO LAYERS OF 15#FELT FOR ROOF MOUDLING&TRIM KELLY-MGORE KM3452-2 I N
CEM. TILES i
`* STUCCO WALL a
TOP OF RIDGE TOP OF RIDGE
N TOP OF RIDGE � � � :T�-?=-i , ': i� -,---i�--T-,�,-, � °° �'
� / , =7-r-----f------Y i:'--YI--��--��--r�`rI-�� � � \ �
� 2ND FL. / i i � I I T_'� ,�- \ \ I 2ND FL �'
TOP OF PLATE
/ TOP OF PLATE
\
� (N)CHIMNEY \
/ o �
� i .
�/ � I!i ''� ° \ � I
o I /
o i
i �
_ \ I o
.
� / io � o i
a�
\ .
,
� �
o �. I�� �
�
i � �
i � �
� , , � ,�; , � \ .
� i � / ° � ,- ' I ;, �`- ' ,'I , �L._� � � � b
2ND FL SUBFLOOR � i� -'�� ' �r-=r'--�-� �1 \
F i i -i- , 2ND FL. SUBF�OOR
� • - - T �-��� -- -- - -- �
i o �.�� r?,-�� , � �n �
1 T F
�
S L . ^o
� -� --T-�-- 1ST FL c�
o TOP OF PLATE �
N TOP OF PLATE o
� o `�
i
��� � v
� '--? —. �
(N)FENCE � ' ' -
- o o �a .
o F- - ----------- i i "� -
_ - -,��- � i I o
� — .. c0 iD - � N I
� .,. ._�T_ . �
.
: , _���r
o T ��`` i,' �-J�T
� -�- �_ �-- -- — -
I ° � ° '
15T FL. N - o I
- �� n' � 1 ST FL.
SUBFLOOR ------ - - ----- ---- --
0 0 0 0 0 0 0 0 0 0 0 , SUBFLOOR
���T_T
� (N)LANDING THE NATURAL(EXISTING)GRADE LINE� �
FWNDATION VENT N0.18-N026 �CRAWL SPACE VENTS DO NOT 'PROVIDE WEEP SCREED AT FOUNDATION PLATE LINE ON ALL STUCCO WALLS (2010 CRC SEC. R 703 6.2.1)
OCCUR IN SHEAR WALLS. WEEP SCREED SHALL BE 4"ABOVE EARTH AND 2"ABOVE PAVED AREA.
2 EAST ELEVATION �
,�4•-,�-o•
WHY
Constuction
DESIGNER
Jack Lin CSLB#964820
6805 Westmoor Way
Son Jose,CA 95129
TEL: (408) 218-0587
Email: fu333�yahoo.com
NI idwa.E�yn�.arrmgwnanta h plma
di o1�d rRrwenlM pr tAia ba�ing
meE by,anE Ne praprty of
M��M7171(,Tpl
a . �.e.tiw..a ma e..xoo.a
ro�..oo aw m�o«�o� �n,
M�+V�cifiM Proj�ct�Nms W euc�
�aaa.aaipn.m.rnqw.�..�f•a p�ma
.nan w�.e eca e�Kio.w�o y
p..,�.n�„o wv����o�m,a�y
p,�w..na�so...r �mo��m�
'itm D�iesim oi
M�Y CRiTIOCIffIF
ui��r �o m e....rwe ey wi
a..�, v� e p.oMe
ny��� m e.0�urcro��.
snowe y n«« n.cs��y
p�not111Mtior hetructlmpe office muet
proY lo
proceeEMp vlt�mY wnatructlm
OWNER:
MR.Bao Ding
TEL: 408-828-9808
EMAIL: ghifeng�yahoo.com
MR. Young Ding
lEL: 408-623-5809
W
C� .
Z W °'
W Q °
o '
� H �
� � o
�
W a °'
� Z V
� Q Z
Z m �
� O W
Q �"� a
�M '
■ �/ U
� �
�
ELEVATIONS
DA�: OS/12/14
�os No. WHY14-0542
ISSUE&REVISION
07/02/14 LANNING REVIE
1 11/17/14 LANNING REWE
12/01/14 LANNING RENE
3
4
5
6
7
8
9
10
11
SHEET N0.
A3.2
DRAWN BY: JL
(N) 1 ST FLOOR ROOF PLAN
SCALE: 1/S"=1'-0"
j .. ,'.. _ �...... _�.....a�`"'�`'�..���' �. -�.
�'�f �� y--�. ';fli•�.K:r;P'�i
t� N ;!.F 5 j`*`�1 I '<�.,......�.,...�,.�.rac��w.,..a+«.a..... ....-,.............v.....�...�..,..,«.s.
�ya,r^m '�a�L..,�, ����'( �cJ
F r,i,:i . .s��.,_...,_ ....-... ._...,. ...�.�. ....,....,-�.•.s.�.---�—�
�!9 . _... .. . .. .
q'�p,c ioi 9'•.��"1'l i:".:
P�,i�t�°i��.,..,3� ._ ��....�K....�._..,�a.
,� �s n-. -�-� y.. -
`i .
0
G�
�
7R' MAX. HFIC;HT
(N) 2ND FL. ROOF PLAN
SCALE: 1/8"= 1'-0"
1
_ �
�
�
SECTION
WHY
Constuction
DESIGNER
Jack Lin CSLB�/964820
6805 Westmoor Way
San Jose,CA 95129
TEL: (408) 218-0587
Email: fu333�yahoo.com
NI idwe.d�aqm.a�y.m.�c.a qa,
indicot�G or r�nvmlM by 1Ais tra�ing
med Ey,anE Ne p�oprty d
�1'�Y C�IfOCII[11
onE wr�nwtM,�wlwd�a ee�o�a
fa u and In nxtion�ith,
U�lpKifi�E proj�ct�Nm�M fuc�
iMa4 asig�s.ortonqwnnls r Dlma
��all Ds usM Ey or EiulosM to my
pwsm,frtn or corporalim 1or ony
puryose��atsoewr Wit�oul t�e
.nu�v�.�,�.e�o�
M�Y CO�TIUCII[l11
NI hformation y[o De+wifi�tl by dl
pwsm�,companin mE propct
rcpnMm����uat.0�nnr m�.
sno��a o�y N* �n�«a �.,�e�<y
aoo�m�n�n�a.�ys,tn�e oM�e�,.�
De natMbd 1or haWctlme proY to
p.oc<sa�a.+in mr coox�u<uon.
OWNER:
MR. Bao Ding
TEL: 408-828-9808
EMAIL: ghifeng�yahoo.com
MR. Young Ding
TEL: 408-623-5809
W
C� .
Z W o�
W Q °
0 '
_ H �
� � o
�
W a °'
� �
Z
(' Q z
Z m �
— o W
Q M a
O/�>� >
■ �ly U
� ��
�
ROOF REF.
�
SECTION
oa�: 05/12/14
�06 No. WHY14-0542
ISSUE&REVISION
07/02/14 LANNING RENE
1 11/17/14 LANNING RENE
12/01/14 LANNING RENE
3
4
5
6
7
8
9
10
11
SHEET N0.
A3.3
DRAWN BY: JL
2010 CALGREEN RESIDENTIAL CHECKLIST—
MANDATORYITEMS
COMMUNITY DEVELOPMENT OEPARTMGNT•BUILDING DIVISION
GUPERTiNO �ERT SALVADOR,P.E.,C.6.0.,BUtLDINO OFFICIqI
10300 TQRRE AVENUE�CUPERTtNO,CA 850143255
(408)777-3228�FAX{�OB)777-3333•4ylldina�taoeAlno.ora
PURPOSE; '
The 2010 CaiGreen Code applies to a�newly conatructed hoteis,motels,lodging houses,dwellings,
dormitories,condominiums,shetters,congregate residenoes,empJoyee housing,factory-built housing and
other types of sweilings with sleeping accommodations and new accessory builtlings associated with such
usea.Existing sRe and landscaping improvements lhat are not olherwise dislurbed are not subjecf to lhe
requirements of CALGreen.
Pro�e�t Na�,�: 18930 Barnhart Ave.,Cupertino,CA 95014-3669
._._ __.. . _.....___ ________-----....--------
Pro�ecrAddress: 18930 Barnhart Ave,,Cupertino,CA 95014-3869
Pro�ec►�escripaon: To bui(d a two stories new house 2,409 S.F.
Instructions:
1. The Owner or the Owner's agent shall employ a licensed professionai experienced with the 2070 Calitornia
Green Buifding Standards Codes to veriry and essure that all requlred work descrlbed hereln Is properly
planned and implemented in Me project.
2. The Ilcensed professional,in coAaboration with the owner and the desi0n prot`essional shall initial Column
2 of this chedslist,sign and date Section 1-Design Verifieation at the end of this checktist end heve the
chedclist printed on fhe approved plans for the project.
3. Prfor to final Inspection by the Building Oepartment,the Ilcensed prolesslonal shall complete Column 3
and sign and date Sectlon 2-Implementatlon Veriflcatlon at the end of this chedclist and submit the
completed torm to the BulMing Inspector.
Pagc 1 of 5 CalGrecn 70IO.dnc re�r.rerf 08�271!1
Pagn A of 5 C�olRrer,n_20/O.Aac rorised 08?7/7!
Page 2 of 5 (,'o!f,rr.en_2010.dac revissd OR�77111
CALGREEN SIGNATURE DECLARATIONS
Project Name: 18930 Barnhart Ave.,Cupertino,CA 95014-3669
Pro�ect Ewd�ess: 18930 Barnhart Ave.,Cupertino,CA 95014-3669
Project Description: To build a two stories new house 2,409 S.F.
SECTION 1—DESIGN VERIFICATION
Cernplete all ilnes d Sectlon 1—"Desfgn Verification"and submlt the completed checklist(Columns 1 and 2)with the
plarn and building permlt appl�aHon to the Bullding Depertment.
Tiae ativner and design prMessionel�espa�slble fa compfiance with CetGreen Staoderds heve revis�i the plans and
certtly lhat Ihe ltema checked above are hereby�ncorporated Into the project plans and will be Implemented into the
project in accordance with the requiroments set forlh in tha 2010 Ca6(ornia Green BuiWing Standards Code as
adopted by the Clty of Cupertino.
Owners Signature
Owner's Mame(Please Prmt)
Deaipn Professional's Signature
Design Prolesslonal's Neme(Please PrinQ
Signatura of License Profecsional responslble(or CalOreen complfance
Name of License Professional rcsponsible for CalGreen compliance(Please Print)
EmaH Address far Llcanse Proteaslonal responsWk for CalGraen complianu
Date
Dafe
Date
Phone
SECTION 2—IMPLEMENTATION VERIFICATION
Complete,stgn and submll the compeied checklist.Including cdumn 3,togelher with aIl orig&�al slgnatures on Section
2 to the Bullding Oepartment prior to Buildfng DeparlmeM flnal inspectton.
I have inspected the work and have recelved sut(�cient documerNation io verify and certify thai the project idenN(ied
above was construcled M accadance wlth Ih(s Green BuiMing Checkllst and In accordar�ce with the requirements of
ce
the 2010 Celifwnia Green 0uilding Standards Code as adopted by the CNy of Cupertino.
i Signat:ue ot Ucense Proteasbne?responaR�le(or CalGreen compllenoe Date
Name of License Professionel reapottaible fa CalGreen oompliance(Please Prini) Phone
Page S of y CdGrrei�_70f O.Aoc reoixd 08/27/l 1
.� . !
Fireplaces•
4.5Q3.1 tnataN only a direct ve�t sealedrnmlwstion gas cx sealed wood- � �
buming flreplace,or a sealed waodstove.
PoilntarK Control .
4.504.1 Dud openings and other related air distribution component openings � �
shall be covered dunng construdion.
4.'3042.1 A�esives,sejalants and caulks shall be wmpliant with VOC and � �
other toxic compound limits.
4.50i.2.2 PaiMs,stains and other coatings shail be compliant with VOC limits. � ❑
4.504.2.3 Aerosol paiMs and other cuatings shall be compliaM with product � �
weiphted MIR Limits for ROC and other toxic compounds. __ _. _____
d.504.2,4 Documentation shall be provided to verity that compliant�lOC I�mit � �
finish materials have been used.
4.304.3 Carpe!and carpet systems shall be complfant with VOC limits. � �
4.504.4 F7t1y(50)percenl offloor arez receiving resilieM flooring shall compty
wtlh the VOC�mission limits defined in 1he Collabora6ve for High Perfortnance � �
Schools(CHPS)Low-emitting Materials List or De certifled under the Resilient
Floor Covenng Institute(RCFq F1oorScore program.
4.b04.5 Particleboard,medium density fiberboard(MDF),and hardwood
plywood used in interia finish systems shall comply with low fortnaldehyCe � �
emission stendards.
Interibr'Moisfure:Cor►trol
4.505.2 Vapor retarder and caplUery break is iristalled et slab on grada
foundaUons. � ❑
4.505.3 Moislure content of building materials used in waA and floor framing is � �
diedced before endosure.
Page 3 af 5 fa!Crren_ZOIO.doe rcvlxed 0&7T,�11
/z"�-`�`f''��
�..,. ..�.. , � ��,.,.,- ��:.. -�f,..,s_..,.-�:.,,.�.�.�:u
.,._i x . ..,.. .
A �r� 1 �`1
's'��' , ,j� �":"{,* . ..�._.. %..���l�,. .,,,.,...,... w.�
, .
,. <,.,.,,. .....,._._.
"a� -�. -.-.,,...,--<.
°�s"�,�`R,Ya:��:
�w�t,;;�._ . . _
,=;::,�':i;,;�;,.,,. -.,. .. �.,s� ...,...a..�.
WHY
Constuction
DESIGNER
Jock Lin CSLB�964820
6805 Westmoor Way
Son Jose,CA 95129
TEL: (408) 218-0587
Email: fu333�yahoo.com
AN'rJeaa,denign�,mangemente h plana
indlcvlW or rq�untW by Uh Aro.ing
a�ned by, d N�propMy of
i 9 Y MRQCIKtI
a�e.Y .rome.�.w.ee a�e a�.aw�a
�«�M �a h���«t�«�.��,.
Ne�aifwE projttt.Nme of euch
idem.dnip�a,vranqaments ar plana
.nai n��xe er a e��o�d io�Y
Dman.firm tt coryaatim Ior any
-iwwe.note«K..rtnwt me
�ne�v.���..��oi
N9YCU�fOCIfIEi
Aq hformet'ion i�to De vttifie0 by tll
per.n,..canono�e.ene u.ok�t
.ee.<x�euinee mac.n u�,r meM.
SToWd any arw,cmflkl or mlmcy
oppeor In!h<trawhqa,thie otfice muat
be nolifieE tw Fatructcns prdr to
prxeedinq�itA my conal�uctlm.
OWNER:
MR. Bao Ding
TEL: 408-828-9808
EMAIL: ghffeng�yahoo.com
MR. Young Ding
TEL: 408-623-5809
W
C� .
Z W �
W a M
� ,
� r"
� � 0
�
W a �
= a
� Z c.i
� Q Z
Z 00 �
— o W
Q M p,
O> >
■ � �
� �
�
CALGREEN
CHECKLIST
DArE: 05/12/14
�oe No. WHY14-0542
ISSUE &REVISION
07/02/14 LANNING REV1E
Q1 11/17/14 LANNING REVIE
2
3
4
s
6
7
8
9
10
11
SHEET N0.
CALG o
DRAWN BY: JL
�
L�
LE�
AC ASPHALT CONCRETE
BC BUIIDING CORNER
BW BACK OF WALK
CB GTCH BASIN
CMP CORRUGATED MEfAL PIPE
CO CLEAN OUf
CRN CROYIN
DW DRNEWAY
�� ��N.87'39,5�3°W. ��51.00' �� � ���;��
—- - -- -- -- -- - EP EDGE OF PAVEM
- - --
-- -- -- -- -- -- -
-—�————————————————�-- � 5�P.U.E�'O EE(S) F�' FCOR fENCE CORNER�
————— — 12'PALA1 — — ——1- —————————————————�——————————————— FD FOUND
——————————— — — — �b�yp � � FF FlNISHED FLOOR
i I c �
I ' o +�'A�',� a +G96�, +, I � fL FLOW L1NE
FH FlRE HYDRNlT
I I �, N I G I FW FRONT OF WNJC
G GROUND
G� GC GARAGE CORNER
� � ,9ra. ap � � GF GARAGE FACE/FRONT
$ � GFC GROUND AT FENCE
I � A' S.1 Go,6p 27.2 � I ' GM CJaS MEfER
I I �r I HCR WWDICAP RAMP
o LOT 57 � �� ��
� � o AREA = 5,355tSQ FT. o � �P ��P��
i i ^ i � i �c LJP OF GUTTER
G I 0/H OVERHEAD
I I PC PROPERTY CORNER
ez o Rw R�raNiNC wnLL
� � o s �0 2o s� srR�r ucHr
12'fREE(S) � I SSCO SANRARY SEWER CLFiWOUT
� � � CP��I I SDIAH STOR DRAIN�AUWHOLE�
I I 18930 BARNHARD AVENU ��� TBC TOP 9ACK ROLLm CURB
.96
� TC TOP OF CURB
IXISTIN6 HOUSE �6°' � � TOB TOP OF B�WK
� I 1 G FF=197.02 TOE TOE OF BANK
I � 8'TREEA � I TP TOP OF PAVEMENT
I I I TRC TOP OF ROLLED CURB
PN TOP OF WAI.L
U/G UNDERGROUND
� � 5 Z � w P �Flm�Y PIPE
I I I 0°ti F o I WA1 WATER MEiER BOX
�°6 �°� I -C1V- CABLE TELEVISION UNE
I I SNRUBg�A �
-E- ELECTFtIGL LNIE
�°�0 -G- GIIS LINE
I I �o +�Q96�� 9.2 i -D- SfORM DRNN UNE NE
� I A 9�0� 6
-T- TELEPHONE UNE
I I 9'T REE, }V 9 61 �E ti�r -W- WATER uNE
` +�9 SHRUB
3 3 enss OF e�iw�cs
I I o c p � THE BEARING,N8T39'S3�N,OF THE CENTER
� � L1NE OF BARNHARD AVENUE,AS SHOWN ON
� �' �N TIiAT CERTAIN MAP FlLED IN THE OFFlCE OF
I I N tO o°`9 N iHE RECORDER OF SANfA CLARA COUNIY,
N Y 28�PALM O6`� ,96� � 'r N SfAiE OF GLJFORNfA,IN BOOK 42 OF A�WS
�A g g AT PAGE 27,WAS USED AS THE BASIS OF
� � i 9�P^� �� � BEARINGS SHOWN ON THIS AUP.
t � � �
I I I +�Q � I ���,A„� 0
�
� � I 24'fREE 1 G9y�� , � � TBM QEV=195.00 QISSUMED)
I �
I—— — —— I_ O19y0 1
_ __ __ __ 1_ __ __ __ _ __ __ �__
_ _ _ __ _ __ __ __ __ __ __ ___
+ 30'fREE �N��
N.87'39'53"W. 51.00' �
UNDERGROUND UfIUiIES. SHOWN PER
a e�a`� MAYFBE DIFFERO�fT TWW RAS�SHOWN.
�`�`9`' �°j .�-a$`' BffORE D(CAVATION.CALL UNDERGROUND
ti............--r 1� s�mcE u�(usn)�-eao-s�2-2�.
�
9M k '�A' �4
� I..f�t�IMF
LOT 57,TRACE N0.1088,MAP Rff:BOOK
B��� ��� �M9�oo � �O' �� 42 PAGE 24 TO 29
E1=195.00 ��'
1.MEhSUREMENf OF BUILDING LINE IS TO
---- -- /----- ----- ---- -------- ---------------------------- ------------- THEFACEOFSNCCOORSIDING
��� NOT IPROVIDED,ONSfTE EASEMENT W�IS NOT
EVALUATED.
MON 3.iHIS IS NOT A TOPO SURVEY. 1}IE
/ WRPOSE IS TO DffINE THE BUILDING
/ FOOTPRINT RElATIVE TO THE PROPER7Y LINE.
/ ��� � .r ,.I.e.�._.._-as+a«..w.-..c.,c�
,�t.�/'�" ��
.: , , /.� . -
� , , �� _
, , � ' . ..�.�...... ,��..,�:-�_..
��' ._ .. . ,. . .
/ sa �
` ��4�¢5 n' t: "s -� '���� . .. . -
�
�' t�k��� F� .
, ��• i
/ ti, t� '`"j .. _ .,.A. , _..,.z .,...,.�,�s_.
�� � • � ��r ��. ..,.........+l+:-.,...
..'E:M1 D } R�� rT' t ..
��Iy�)) '`ti���7 �r�' , __ . .._,. ,_._..
��I�� `���4.4.. •_. ._... ... . .. .. . .s "
O :d: . �� w�a...�•r...,a�.r
� ���,-������
`�,�.,J;`;,��^�..
�
DING
RESIDENCE
18930 BARNHARD AVENUE
CUPERTINO,CA
APN:375-33-007
W E C
i A s E O C 1 A T E S
�2625 M�DLEFIEI.D RD#658
PAIA ALTO, CA 94306
�TEL: (650)823-6466
FAX: (650)887-1294
IICENSB STAI�S AND SIGNATURE
����
Cs ;_,�f�
U�'L�,4tA ip�
������.�
�
z *
�.,� �..ox�s ��r
r'�`rn.,�a.iL� e�`�
-�.
ISSUED
DA�� Oct 3,2014
SCALE: 1"=10'
DRAWN: �
10018
SHEEf TITLE:
SITE
SURVEY
SHEET N0.
C.�
Qe v+ec
�
�,
i
' f
f
� � �-
0 � �
�
� � C
Q �
W �
p� z �
� Q :
Z � o
— o �
Q M 0
O�
. 00 �
� �
�
3D
��n�n�r►�rn�
,