Loading...
14100131Patricia Garcia From: Sent: Thursday, May 07, 2015 9:16 AM To: Patricia Garcia Subject: Bulding permit 14100131 - Please cancel Patricia, We talked a short while back. Looks like this building permit was requested by solar panel contractor company (I got a quote from SunRun). I decided not to go ahead with the project of installing solar panels on my roof. So please cancel this permit. Best Regards, CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 11882 SHASTA SPRING CT CONTRACTOR: REC SOLAR, INC. PERMIT NO: 14100131 OWNER'S NAME: SAN LUIS OBISPO, CA 93401 PHONE NO: (888)657-6527 ❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL COMMERCIAL INSTALL (10) PV SOLAR PANELS ON EXISTING SFDWL, License Class Lic. # 70S l 100 AMP SUBPANEL ao Contractor Date I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the Sq. Ft Floor Area: Valuation: $6500 performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this APN Number: 36655023 00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT IRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WIT 180 DAYS PERMIT ISSUANCE OR to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save 180 DAY _ FROM LAS CALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities, judgments, -- costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply Issued by --'� Date: with all non -point source regulations per the Cupertino Municipal Code, Section 9 18. / / RE -,ROOFS: All roofs shall be inspected prior to an roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. ❑ OWNER -BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) I, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(a) should I store or handle hazardous I have and will maintain a Certificate of Consent to self -insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and I have and will maintain Worker's Compensation Insurance, as provided for by the Health & Safety Code, Se tionA5 5, 25533Can5,4. Section 3700 of the Labor Code, for the performance of the work for which thispermit Owner agent:Date: is issued. or authorized I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code, I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued (Sec. 3097, Civ C ) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, ARCHITECT'S DECLARATION costs, and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understand and will comply with all non -point source regulations per the Cupertino Municipal Code, Section Licensed Professional 9 18. Signature Date ALTERNATIVE ENERGY PERMIT APPLICATION is COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION p 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 CUPERTFNO (408) 777-3228 • FAX (408) 777-3333 • building(a,cupertino.org \� 1 \ PROJECT ADDRESS I ,! APN # I ^ to -02 OWNERNAME AILSTREET ADDRESS � C STAT ZI � FAX se_ a,4 ❑ OWNER ❑ OWNER -BUILDER ❑ OWNERAGENT CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME ^ LICEIJB'ij 125VI LICENSE E BUS. LIC # COMPANY NAME v IE-MAIL(J FAX STREETADDRESS V ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS. LIC # COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE USE OF ❑ SFD or Duplex ❑ Multi -Family PROJECT IN WILDLAND PROJECT IN STRUCTURE: ❑ Commercial URBAN INTERFACE AREA ❑ Yes ❑ No FLOOD ZONE ❑ Yes ❑ NO ❑ SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PANELS: NUMBER OF PANELSIUNITS: KILOWATTS (COMMERCIAL ONLY): TOTAL VALUAT DESCRIPTION OF WORK . ; w , - ` Scla.,n.Q,l � a PV_n1fhA16i kA&I -1 I96Ln-e_l By my signature below, I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. I hNp read this application and the informationmeda: d the Description of Work and verify it is accurate. I agree to comply with all plicable local ordinances and state laws relatize represen tives of C erti to enter the above -identified ption purposes. Signature of Applicant/Agent: Date: 1g -?1W7 SUPPLEMENTAL INFORMATION REQUIRED PVApp_2011.doc revised 03/16/11 CITY OF CUPERTINO FFF. FCTTMATOR — BUILDING DIVISION ADDRESS: 11882 Shasta spring ct DATE: 10/22/2014 REVIEWED BY: Mendez APN: BP#: *VALUATION: 1$6,500 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY SFD or Du lex USE: P Alternative Energy System IPHOTOVRES Photovoltaic System PENTAMATION SOLAR -RES PERMIT TYPE: WORK install 10 v solar panels on existing sfdwl 100 amp subpanel SCOPE $0.00 Ofi3c 5'jcC h, fnV Plumb. flan Cheel, Plumb. Penna;a; 1`ee Otlwi Plumb fns; , 1117w1h, hi s11. Fee Elec. Plan Check 0.0 1 hrs $0.00 Elec. Permit Fee: IEPERMIT Other Elec. Insp. 0.0 hrs $48.00 1"I c'. h . NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Pire, Janttary sewer uisrrlcr, acnoor mi ___ I*--- ,. - 1.....,.11 #L.., -1------- rnntact the Dent for addn'l info. FEE ITEMS (Fee Resolution 11-053 Eff. LL 31 FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 = # $236.00 Alternative Energy System IPHOTOVRES Photovoltaic System Suppl. PC Fee: Reg. OT 0.0 hrs $0.00 PME Plan Check: $0.00 100 amps $48.00 Electrical IBELEC200 Services Permit Fee: $0.00 Suppl. Insp. Feer Reg. ® OT ro,0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $48.00 _FT Administrative Fee: 1ADMIN $45.00 E) Work Without Permit? 0 Yes (F) No $0.00 Advanced Planning_Eee $0.00 Select a Non -Residential Building or Structure G 0 i Travel Documentation Fee: ITRAVDOC $48.00 Strong- Motion. Fee: IBSEISMICR $0.85 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $1.00 aIBM$142.85 $284.00 TOTAL FEE: $426.85 Revised: 08/20/2014 T, 5 E R I F1, I ® L— I L— I I I d L— I 'I L.- I -N, t -j I LJ L.. i \ .J L.- I \ I i,._...JJ NominalPower-P,,(Wp) - 295 NominaiPowerVoltage'-V,,M' ZY-5AS 29D NominalPowerCurrent-lW (A� SM &M 664 &W 577 VA Open Circuit Voltage-V.oc(V) Cft- it W+5 NominaFbpemftcell temperature MOf7 W+5 01+5 v/+5 NominalPowerVoltage-V.P(V) zw (mai,degtessioninperformanceoffi p.a.) �iAi;IEC(�1"� i[� (ammoola resistance)&. Ms egg Nominal PowerCurrent- Ip (A) as 90 Did Open Circuit Voltage -Voc(V) ���f products, services and Investment op portuntties for the solarandelectronics industries. Togetherwithour partners,wecreate value by .373 324 37.6 37,8 Short Circuit Current- Isc (A) 835 am a,j* WK 90 142 "s .A HS S W, 6.6 NominatPower-P,p(Wp) U9 1 VJWLBB M NominaiPowerVoltage'-V,,M' ZY-5AS 29D NominalPowerCurrent-lW (A� SM &M 664 &W 577 VA Open Circuit Voltage-V.oc(V) 34 Wo A9 1A67' ShortUrcuit.Current- Isc(A) 6M 7AD 7M 7.V 7.3 7.24 NominaFbpemftcell temperature MOf7 .# "AA japarproductwarranty 25ft"arlinearpoweroutputwarranfT (mai,degtessioninperformanceoffi p.a.) �iAi;IEC(�1"� i[� (ammoola resistance)&. Y�!{saFt iMst • seventy level 6�. PVQ KemberofPVCydee ii"��>Csi�46fat�E1[rA�011`�' ���f products, services and Investment op portuntties for the solarandelectronics industries. Togetherwithour partners,wecreate value by Vw23Wemployeesworldwidegeneratedrevenuesofmore 0=01IDblllion,iR billion:. - ��L wwwrecgroup.com a lCeree r REC PeaMeduks i AEC Peak Energy Integrated 1P addles, (valid as ofSepterrmer1,2011) Th is:Lirriited Wawa , lts sial d onlyf i Nord sAmer`ica, Central Ar-nerica:and South America' and for all REC Products �,(as defined above) soldlaYter,Septemborl,.2011 ar later. REC'MOD:ULES PTI IfD:((ea''theWanrtar`orRCisses>he foowingvountaryarrantyt-userwhor purchased the ProdOO tin oine�.o`ft.he;above;mentianed countri' and putthe Product into use for the firsttime (the`tOrigmal End-Userl. In additlon1'6t id,rights>underithis Limited Warranty, the Original End -User may be entitled to -statutory warranty rights under:applicdble nationallawsbwhi hishall notbe affected orgimited in anyway by this Limited Warranty. 1. 1prodluuctB9l'larm Subject to the terns and�cenditlon5fc►fythis L[mited Warranty, REC ,warrants that the Products: • Are ''free from dlefect .iin material andtworkmanshipfor a period,ofl0years-flrom the date of purchase by the Original End -User (note*xceedti ga maa6r'i )e:riod.ofl:0:5years fram:thedate of production as identified on the Product) (the -'Warranty Period) �uso8nn.a'ccordance witKthe-installationinstructions available to download fsrom www. recgroup.com. Willremain safearid operatuonal if cable and corinectorplugs are installed profess ionallyand are not permanently positioned.in�wai6,er; provider however,thatdarrageto the cableicaused by:abrasion on a rough surface due to insufficient fixii arrto;unprotecte4 r%nning o'fthe cable over sharp edges.is�excluded. Damage caused by aniirnnals is also excluded. O Will;not.,exp::erlence-freezing.up=afthe�,aluminum•frames if installed correctly. The outer appearance ofthePro, ck, indludingscratches, stains,,rust, mould,.discoloration and.other signs of nonrnal wear and tear, which o.cciurred anfter deliver y or'tnetallatioa, do.not constItUte defects, provided the functionality of the Product Is not affected. Glasslbreak gecai7, shutes adefed ,' Iy if.not causedby any external influence. If a defectoccurs duiringth,eWilrrantyPerted�affectingthe'functionality of the Product, REC will, at:its sole option: n Repairthe defectlweProduct. Re.placethe Praduct.with�anjegu'ivalentproduct. Refund the currentma ket,price+of an>equivalerit product at the time of -the claim. ll.Paws -l; Utpaut m Subject to the termsand.�c tn_lltlar� oft '.is ited:Warranty,.REC uilarrants thattheactual power output of the Product will reach at least 97% oilthe i ameplate po�penowtspecified ori the Product during :the firstyear (calculated from the date of production as identliged om the Product). Rr<arn the second year, the actual power output will annually by no more than ,0.7%,:foraperiodof,24,years,so!ith.atbythe'endofthe25thyear,an.actual.outputofat east80:2%ofthenamepilatepower outspecified on theProduictw0ltre adhloved. This 9 wer to nat ucaiillde mei on of theggass, the solar cell, the emmobeddli g ll, thejuneOnibox al ilo ennaa bora-, nderinermmi uase. if theiProduct:does rwtireach the;warrantedipower output levelsset:outabove when -measured by the'Warrantor or by an independent:measurfngalnstltute;agreed-to :prior totestingbythe'Warrantor, under standard test conditions- IEC 61215) and taking into accourit a.--*3%�tolerance range, then REC�will, at its sole option: • Repairthe.Product • Replace -the Prodfuct;wIth,an egWvaleritproduct orto supply additional modules as necessaryto_achieve the warranted percentage of specified powerout ut. • Refund the current, rriarketpriice;of an equivalent product at thetime of thetdlalm 1 excluding moddles show1ng"4 =asipart;offibetproduct:name. z Defined as all member states afthe:Organiza ion of.American States,'OAS. Rev. G:1, 5-e9tember2MI This warrantyis only appllcable Inthe member states of the Organization of AmericanSStates, OAS 119a vadrra"Isy %aaunamrm4uns,; wa nammuanas arm ZXclusoons. 1. This Limited Warranty is not.transferable by Original End -User, except to a subsequent owner of the solar power facility atwhich the Product was originally installed and remains installed, provided that this solar power facil airy has not , beenaltered in any wayo.rmoved from the structure or property at which it was originally installed. 2.. Notification of arwarranty claim hereunder must be given without undue delay after detection of the defect aradiprior to the expiration ofthe applicable Warranty Period and: in accordance with the procedure as set out in section IV below 3.. Please mete that: thirs Inuit Wiarraunt ¢Ibex not covert nor w1 tha.W arranntor raim burse, anyon-site Babowor other oastslacuroret k�con necdo n-withthedo-i nstaibt.i®nswam® a of defective Products, transport o t:hare- Instailladons of rep tacedi®r repalrodPooducts erasnycoau ponen tL 4. The Warrantormay use remanufactured or refurbished parts or products when repairing or replacing any Products under this Limited Warranty. Any exchangedor replaced parts or Products will become the property of REC: The WarrantyPeriods set out In sections I. and 11. ab-ave.will not be extendedin.anyway in the event of a replacement or repa* of a - Product. 5. This Limited Warranty requires that the Product is installed accordingto the latest safety, installation and operation instructions provided by REC and does not apply to damage, malfunction, power output or service failures whiich have beencaused by: (�) repair, modifications or removal of the Product by someone other than a qualified service technician; (b) any improper: attachment, installation or application of the Product or (c) abuse, misuse; accident, negligent acts,. power failures orsurges, lightning fire; flood, accidental breakage, actions of third parties and other events or•accidents outside REC's reasonable control and;/br notarising under normal operating conditions. 6. This Limited Warranty is provided voluntarily and free of charge and does not constitute an independent guarantee promise. Therefore, if any defectmaterially affects the functionality of the Product or results in a power outp:vt below the warrantedlevels, the Original End User's remedies are limited exclusively to the remedies set out under sections I. and 111.1n the warranty cases specified herein. REC ASSUMES N0WARRANTI ES, EXPRESS OR IMP LIIE% OTHER'THAK THE WAR ANTIE MADE P EREINAI SIPIECIlFICALLY. DISC P AIMS ALL OTHERWARRANTIES,. MERCHANTABIII.B'i OR FffN ES F® , A P9ARTIC,ULAR! PUR,IPOSEo. REC EXCLUDES. ALL LIABILI UIPES-FOR AN Y SPECIAL,INCIDIrgt IA4,,, CONSEQUENT, IIAL OR PUN ITTIVE-DAMAGE FROM 1H UIS OR LOSS OF -US GF -THE PROD gCT TOPEg gw : WARRANTED INCL DING NOT LIMITED 10 DAMAc ES FOS LOO F'POW EP, LOSTROFITS, OR SAVINGS NOR IEXPPENS ES ARI�IIs1S!FRg~D14,THI )-PPA (M AIMS: This does not apply to the extent the Warrantor is liable under applicable mandatory product liability -laws or incases of intent or gross negligence onthe-part of the Warrant>Tr. 7. This Limited Warranty shall be governed by and construed in.accordance withthe laws of the State of California without giving;effect to its conflict of laws provisions. The United Nations Convention on Contracts for the International Sale of Goods (1980) shall not apply to orgovern this Limited Warranty or anyaspectof any dispute arisingthere frornl IM, War ran q Chimra Procedure Claims under this Limited Warranty must be made by notifying the authorized distributor or seller where the Product was first purchased. A claim maybe registered at: www.recgroup.com/warranty For a Warranty Claim:to be processed, proof of the original purchase of the Product and any subsequent sales including transfer of this Warranty need to accompany the claim. The claim must include a description of the alleged defects, as well as the Product's serial:number(s). Prior to returning any Products or components to REC, an RMA (Return Merchandise Authorization) number is required, which may be obtained by contacting REC via the aforesaid address. This warranty is valldfor Products sold on or after September], 2011. Singapore, 01.0 201 Thiswarrantyis'onlyapplicable in themember states of the.Organintion of American States,OAS Rev. G.1, Septernber=l The most common residential inverter is the ideal size for an average - sized family home. This family of -single-phase string inverter complements the typical number of rooftop solar panels, allowing home -owners to get the most efficient energy harvesting for the size of the property. This rugged outdoor inverter has been designed as a completely sealed unit to withstand the. harshest environmental conditions. One of the key benefits of the Uno family of single-phase inverters is the dual input section to process two strings with independent MPPT especially useful for rooftop installations with two different orientations (ie East and West). The high speed MPPT offers real-time power tracking and improved energy harvesting. The transformerless operation gives the highest efficiency of up to 97.0%. The wide input voltage range makes the inverter suitable to low power installations with reduced string size. • Each inverter is set on specific grid codes which can be selected in the field • Single phase output • Dual input sections with independent MPPT, allows optimal energy harvesting from two sub -arrays oriented in different directions • Wide input range • High speed and precise MPPT algorithm for real time power tracking and improved energy harvesting • Flat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power range • Outdoor NEMA U rated enclosure for unrestricted use under any environmental conditions • Integrated DC disconnect switch in compliance with international Standards (-S Version) • RS -485 communication interface (for connection to laptop or datalogger) • Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI -DESKTOP • Integrated Arc Fault Detection and Interruption (-A Version) a Nominal Output Power W 3000 3600 3300 3800 4200 MaximumOutP ut Power W 3000 1 33002 3300 3600 1 40002 4000' ' 3300 r 42002 42002 ' 4200 4.600' 46002 Rated G rid ACVoltage V 208 240 I 277 206 240 277 208 240 i 277 s; 208 240 277 IrputSide(DC). _. ._w�= _.. _ _ § - v-. 2 NumberofIndependentMPPTChannals 2 2 2 Maximum Usable Powerfor Each Channel -.... W 2000 3000 3000 3000 Absolute Maximum Voltage (Vmax)_ V " 600 _ Start-Up Voltage(Vstart) - V j Y 200 (adj. 120-350) Full Power MPPTVokage Range V i 160-530 120-530 14D-530 140-530 Operating MPPTVokage Range V _ 0.7xVstart-5580 (>= 90V) - - - ----- ----- Maximum Current (ldcmax) for both MPPT in Parallel A 20 32 32 32 Maximum Usable Current per Channel A 10 16 16 16 Maximum Short Circuit Current Limit per Channel A 12S 20.0 200 20.0 Number ofWire Landing TerminalsPerChannel2 - ._ .__. __.. _ pairs Array Wiring Termination Terminal block, Pressure Clamp, AW310-AW34 Qutput Side (AC) Split Split- 10/2W 10/2W Split ~ 10/2W 10/2W Split- 10/2W Connection Type Grid3W 10/2W 10/2W 0/3W 10/2W 0/3W 0/3W .__ 0/3 AdjustableVoltage Range (Venin-Vmax) V 183-228 211-264 244304 183-228 211-264 244304 183 228 211 264 ' 244304 183-228 211-264 244304 Grid Frequency Hz 60 - Adjustable Grid Frequency Range . Hz 57-605 Maximum Current (tacmax)Arms 14.5 14.5 12.0 17.2 16.0 16.0 16.0 16.0 16.0 _ 20.0 20.0 20.0 Power Factor -- .. > 0.995 _. .. - ..._ _ _. Total Harmonic Distortion At Rated Power % <2 Grid Wring Termination Type Terminal block Pressure Clamp MG10 AWG4 - ProtectionDevices ` 4 �� Input Reverse Polarity Protection Yes Over-Voltage Protection Type Varistor, 2 for each channel PV Array Ground Fault Detection Pre startup Rlso and dynamic GFDI (Requires Floating Arrays) Output Anti-Islanding Protection - _ Meets UL 1741AEE1547 requirements _ .. External AC OCPD Rating Ate_ 20 ; _ _ 20 , - . 15 25 20 20 20 20 20 25 25 25, _ _ _.. __. Over-Voltage Protection Type r r Varistor, 2 (L, - L2 / L, - G) Efficiency- fficiency ,MaximumE(ficiency Maximum Efficiency 969 97 97 97 CEC Efficiency % 96 Operating Performance Night Time Consumption _..__W^"a_._ <0.6 Stand By Consumption Wens <8 Communication - User-Interface - 16 characters x 2 lines LCD display Remote Monitoring (1xRS485 incl) AURORA-UNIVERSAL (opt.) Wired Local Monitoring (1xRS485 incl.) PVI-USB-RS485_232 (opt), PVI-DESKTOP (opt) Wireless Local Monitoring PVI-DESKTOP (opt) with PVI-RADIOMODULE (opt) Environmental Ambient Air Operating Temperature Range *F CC .-. _ _ 13 to+140 (-25 to+60) with derating above 122 (50) - - Ambient Air StorageTemperature Range °F CC) -40 to 176 (-40 t0+80) _ Relative Humidity %RH0-100 ..... __._.. _-.._.. condensing„ Acoustic Noise Emission Level db (A) @1 in i < 50 Maximum Operating Altitude without Derailing ft(m) 6560 (2000) Mechanical Spa cifications. Enclosure rating NEMA 4X Cooling Natural Convection Dimensions (H x W x D) in (mm) 33.8 x 12.8 x-8.7 (859 x 325 x 222) . ......... Weight <47.3 (213) Shipping Weight Ib (kg) <60 (27.0) Mounting SystemWall bracket Trade size KOs:Qeax1%21and Conduit Connections' (tea x 1-1/4, 3 places side, front, rear) Side: (2) plugged 3/4"openings, (2) Concentric EKOs 3/4;1" _Back (4)ConcentricEK0_s_3/4 I'__ _ -- DC Switch Rating{Per Contact) AN 25/600 Safety Isolation Level Transformedess (Floating Array) Safety and EMC Standard UL 1741 IEE1547, IEE1547.1, CSA C222 N.1071-01, UL1998 UL16998, FCC Part 15 Class B Safety Approval .,CSA. Warranty :. Standard Warranty Extended Warranty years 15 & 20 Available Models12 Standard-WlthoutDCSwtlehandlMdngBox . PVI30-0UTD-US PA46-0UTD-US PVI-3.8-0UTD-US PVI-42-OUTD-US _- Standard -With OC Switch and Wiring Box ._ PVI-3.0-0UTD-S-US .... ... .-, PVI-3.6-0UTD-S-US PVI-3.8-0UTD-S-US PVI-4.2-0UTD-S-US With DC Switch, Wiring box and Arc Fauk Detector PVI-3.0-0UTD-S-US-A PVI-3.6-OUTD-S-US-A PVI-3.8-OUTD-S-US-A PVI-4.2-0UTD-S-US-A and Interrupter *All data is subject to change without notice 'Capability enabled at nominal AC voltage and with sufficient DC power available 'When equipped with optional DC switch and Wiring Box • ! • • a Mi LA S N _Arww� ower-onecom T-- `77773"F 77777 rOne Renewable Energy •Worldwide Salesfices tr Name/Regilon aha Asia Pa `'+612097,2,513&79g85888 111 sales australia@power one ,com Ana (Shanghai)) - $ A"zin Pei�ic 6 21 X505 69088 sales.chna@power onecom ha Asre Pac�fi`t +65 6896 3363 sales India@power-one com pan Asri'acific 03 4580 27141+81 34580 2714 sales�apan@power one com' iga ore Asra �aGific +65 6$96 33b3 sales singapore@power-onexom lgiumZTheNetherlantls/Luxembourg E roper +3222060338` sa)esbelgium@poweronecom ince urope' +33 (0)141 796740 sales France@power one com many Europe . +49{7641955 2020 sales germany@power one com .ece Europe 00 800 00287672 sales greece@power-one com Euroae i 00 8U0 00287673 sales Italy@power one com am Europe R +34,91 879 88 54 sales pato@power one+com rtetl`IUngdom EU�Co,pe� +44103 823 323 sales ok@power one com baK s�ian? tlleE sty +97150,104142 salesdubai@power oneco� x ei z§ Mitld)est +92.03°5448884 sales Israel@power.-one com, ada Horth America +1877 261 137,4' sa(es.canada@power one corn R4East NorthAmenca +1 S77 261 1374 saleS.usaeast@power one com- Atentral NorthAnenca,1;87T261-1374 sales.uacentralpower-onecom' IC=West r _ _ North4menca +1:8772611,3,74 sales:usawest@powerone:com _ - Renewable EnemySaluliaar STANDARD PRODUCT WARRANTY Seller warrants Products manufactured and sold by Seller will be in good working order In accordance with Seller's standard specifications upon delivery to Customer, and that Monitoring Services will perform substantially in accordance with the service decrrintinn or the and user documentation as follows Product North Worldwide Except America North America Single Phase String PV 10 years from 5 years from Inverter shipment shipment Three Phase String PV NA 5 years from Inverter shipment Less than 10kW Three Phase String PV 10 years from 10 years from Inverter shipment shipment greater or equal to 10kW Central PV Inverters -- 5 years from 5 years from shipment. shipment Wind Inverters 5 years from, 2 years from shipment shipment Accessories 2-5 years 2-5 years from from shipment as shipment as specified by Seller specified by Seller Combiner Boxes 5 years from 5 years from shipment shipment Micro Inverters 10 years from 10 years from shipment shipment Concentrator Data Device 10 years from 10 years from (CDD) Hardware Only shipment shipment Aurora Micro Inverter 10 years from 10 years from Hardware Accessories shipment shipment Aurora Vision- 2 years from 2 years from activation activation a. If within the applicable warranty term, any Product or Services shall be proved to Seller's satisfaction to be non -conforming, or if such Products or Services become inoperable due to defects in materials or workmanship, such Product or Services shall be repaired or replaced at Seller's sole option. Repair parts or replacement products may be new, remanufactured or refurbished, at Seller's sole discretion. Corrective actions on any defective Products or Services covered by warranty shall be initiated by Seller within three (3) business days of receipt of written notification of such defect from Buyer, unless prevented by a force majeure event, or by Buyer or any third party. With respect to defective Monitoring Services, if Seller is unable to correct the defect or re -perform the Monitoring Services or to deliver a substitute service within one hundred and twenty (120) days, Seller will provide,Buyer with a pro rata refund of any pre- paid fees for the remainder of the Contract term and the refund shall be Buyer's sole remedy. With respect to defective hardware, If the Seller is unable to correct the defect or fails to deliver a substitute product within sixty (60) days after receipt of the defective hardware, Sellerwill provide Buyer with a pro rata refund. Buyer shall cooperate with Seller as required to perform corrective actions. A defect is deemed to have been corrected when the repaired or replaced product is shipped to Buyer or when Monitoring Services operate in a joint test performed by the parties or when Buyer finds the Monitoring Services to be in operation, but in all events no later than one (1) day after Seller informs Buyer that the defect has been corrected. If a defect claimed by Buyer is not covered under the scope of this warranty, AURORA Photovoltaic Inverters Buyer shall pay Seller for all work related to the research and identification of the defect according to Seller's standard price list then in effect or, with respect to any work performed by a subcontractor, according to the rates charged by such subcontractor. If no defect is found, Buyer shall pay troubleshooting costs in the amount of $250 for String Inverters that have a power rating under 10kW, $500 for String Inverters that have 10kW and higher power rating, $1,000 for Central Modules and $75 for Micro Inverters. b. Extended warranties of up to five, ten, fifteen or twenty years for PV String Inverter products may be purchased within thirty-six (36) months of commissioning. c. As specified by Seller, costs of all or part of inbound and outbound shipping costs for products covered by warranty may be covered by Seller. Buyers who fail to return the defective unit will be charged for the replacement unit. d. The following events are not covered by warranty and may void Buyer's warranty: i. Failure of Buyer or an installer to follow Seller's installation, operation or maintenance instructions; ii. Repair, modification or movement of the Product by Buyer or anyone other than Seller or its authorized representative, or incorrect attachment to other products not provided by Seller; iii. damage resulting from power surges and acts of nature, Including but not limited to storms, lightning, overvoltage, fire, flood, pests, or other events outside of Seller's control; iv. damage resulting from abuse, misuse, negligence, accident, action of third parties, improper or noncompliant use or operation, including inadequate ventilation and circulation, improper installation, commissioning, start up, maintenance, or storage, excessive pollution, dirt or dust intrusion into the Product, or installation in a corrosive environment; v. abnormal or unintended use; vi. damage during transportation; vii. normal wear and tear; vill. damage resulting from failure viii. damage resulting from failure to properly maintain the Products, or from unauthorized repairs or repair attempts; ix. labor, installation, removal, transportation, or reinstallation of components for warranty service or any other expenses that may be incurred in connection with repair or replacement of a Product, including, but not limited to, costs related to unusual Installation conditions, including impediments to access (including inadequate elevator access), rental of special tools or removal or installation of parts necessary to mount or remove the Product; x. temporary loss of power or production (Including any rebate, refund, or other benefit associated therewith); A. consumable components of any Product, including but not limited to fuses, filters, fans, and batteries; xii, aspects of any Product not affecting its function, including but not limited to cosmetic aspects; All. damage to equipment not manufactured by Seller or resulting from use with other products not provided by Seller, including External Facilities; or Av. costs arising from Buyer's failure to provide Seller or its authorized representative with adequate access to the Products. e. With respect to Products or Monitoring Services for which Seller has received the full purchase price, Buyer's warranty rights may be assigned, without Seller's consent, to any end user of the Products or Monitoring Services for the term of the remaining warranty period. Seller's written consent is required in order to assign warranty rights for any Products or Monitoring Services for which Seller has not been paid in full. f. Any extension of the standard warranty must be specifically agreed to in writing by Seller and shall be at an additional cost to Buyer. rive viw ; 9&MV17bkfimwSaeh a7s BCE.00689.1_AB fre/'-�lle� AURORA �Aenewable Energy So/uflons Photovoltaic Inverters WARRANTY REGISTRATION CARD END-USER NAME/SITE LOCATION Site Address City/State ZIP Code Site Phone E -Mail NAME OF INSTALLATION COMPANY Contractor's License Number Address City/State ZIP Code Telephone E -Mail Power -One Inverter Model Number Power -One Inverter Serial Number Manufacture of Panel(s) Panel Model Number Number of Strings Connected to Inverter Number of Panels per String Installer Printed Name Date of Commissioning Installer Signature Today's Date Power -One Renewable Energy Solutions LLC Attn: Global Services Department 3201 East Harbour Drive Phoenix, AZ 85034 Tel#:1 +877-261-1374 Fax#:1 +480-452-0111 RE-Warranty-Americas@Power-One.com wer-©W® 'Awewob/e &eigySolofions BCE.00689.1_AB L �IL W 3;T 1' F Fpit L�4t 1�TJL S V,. W LEMO, pr 7fl 3, Nt1�FaSE ---------- OEM---------------------- MlR �� f�KieiASrAR 7h__... g — •,�:.�i• m� Li ��`, SPF;i"R �IPF�fIT tuFi�lil� TT�'�� I -VA 4MQE NUT T mg �r1. r ori r� ffil'4A$E ��•'� W�,/ Fiu&�.. LI•r� ���i,� 1. i3 1" R�1f PROJECT NOTES: SYSTEM INFORMATION VICINITY MAP - SCALE: NTS MODULE NOTES: TABLE OF CONTENTS 1. 2550W DC, 3000W AC SOLAR PHOTOVOLTAIC SYSTEM. 1. REC SOLAR: REC255PE(BLK) DIMENSIONS: PAGE 2. (10) REC SOLAR: REC255PE(BLK) MODULES WITH (1) MAGNETIC TRUE 65.55" x 39.02" x 1.5" # DESCRIPTION POWER -ONE: PVI-3.0-OUTD-S-US-A (240V) INVERTER. ARRAY PITCH ORIENTATION ORIENTATION °°� M A�' 2. PORTRAIT: CLAMP 8.2"-16.4" FROM EDGE 3. TWO STORY COMP SHINGLE ROOF AT 25° PITCH. �3. LANDSCAPE: CLAMP 0"- 9.8" FROM EDGE 4. CONSTRUCTION FOREMAN TO CONFIRM FINAL CONDUIT AR -01 25° 1660 180° $' a Mµ"` - PV -01 SITE PLAN &MECHANICAL RACKING NOTES: RUN PLACEMENT WITH CUSTOMER. h f' 1. SNAPNRACK SERIES 100 OR S100 UL LISTED; PV -02 ELECTRICAL 5. ROOF STRUCTURE: 2X6 RAFTERS 16 OC WITH 7 MAX " UNSUPPORTED SPAN. _ FLUSH MOUNT L -FOOT. SEE PEN D01. ^^. 2. 8'- 0" MAX RAIL SPAN 6. APN #: 36655023 t �� 3. 2' - 8" MAX RAIL END OVERHANG -PV-03-- THREE LINEDIAGRAM7. CONTACT: SIVA BUDARAJU, (408) 242-3192 4. RAFTER AND PENETRATION LOCATIONS TO BE 8. DESIGN CRITERIA: PV -04 SIGNAGE 8.1. SYSTEM WEIGHT: 3LBS/SQFT. M DETERMINED IN THE FIELD < 5. LAG SCREWS: 5/16" X 3.5": 2.5" MIN EMBEDMENT 8.2. EFFECTIVE WIND SPEED: 110 MPH 3 -SEC GUST. § `" PV -05 SIGNAGE u r SITE PLAN - SCALE =1/16"=1'ANs ® D1 - AR -01 - SCALE: 3/32" =1'-0" CHECKED BY ' -6'-2"—,' 33'-2" 16' NOTES TO INSTALLER: (E) RESIDENCE ARRAY WILL BE VISIBLE FROM ADJACENT PATE PROPERTIES 7'-2" PL EPT. FIRE SETBACKS (3' TYP) DATE 5 6". PL PL ', 5'-2" (E) DRIVEWAY SHASTA SPRING CT. A fFl_-�'__ i a PL (E) SERVICE ENTRANCE & MAIN PANEL (N) SUB PANEL (E) FENCE PL I 24'-8" y PL 5' PL (N) ARRAY AR -01 (181 SQ.FT.) (N) INVERTER WITH INTEGRATED DC DISCONNECT (N) AC DISCONNECT (N) SUN RUN METER SUNRUN, INC. 2300ZANKERROAD,UNITF,SANJOSE,CA95131 DESIGNER: sunrun CA CL#750184 PHONE 40"94-3082 REGALADO FAX 408.8949294 0 DRAFTER: OEPOMO "TID .WEPT. — (E) CHIMNEY D2 - ROOF SECTION C QQ�UNtTY DE`A.2 --ME BUILDING NO APPiZOVE Tha sat of plans and spc�il',.t ons UST be kept at th3 sOLAR job site during construct .. ; . is u lawNI to ke -���.,+ RYiCKING� ChB ps or afteratlo C. ga 04�IAP t amtron Without app+ :I . n theBBuiillding Off The SWOng of this p+_n c;-' acifi SHALL N, - beheld to per i ort • L -',Y01 ral of the viclat�'_' d any provi c� _`ini nce or State I DATE PERWT NO. � MING 0 (E) PROP SUNRUN PROJECT NUMBER: BUDARAJU (102R-882BUDA) M( 0 222014 uoding Department a,3 ol GCT 2 2 20% REVIEVVED FOR CODE COMPLIANCE Reviewed 8y: ��.., 2X6 TRUSSES 2 16" O.0 LUAU =AKIN" VVALLJ BUDARAJU RESIDENCE 11882 SHASTA SPRING CT, CUPERTINO, CA 95014 SITE PLAN & MECHANICAL TOP PLATE REV: A PV -01 8/5/2014 LINE DIAGRAM: UTILITY GRID 120/240 VAC SINGLE PHASE SERVICE 141 METER _#_:- SUNRUN INSTALLED 100A PGE 1005145724 SUB PANEL FACILITY LOADS 50A SUB FEEDER BREAKER EXISTING MODULE CHARACTERISTICS SYSTEM CHARACTERISTICS - INVERTER 1 REC SOLAR: REC255PE(BLK) 255 W SYSTEM SIZE 2550 W OPEN CIRCUIT VOLTAGE 37.6 V SYSTEM OPEN CIRCUIT VOLTAGE 404 V OPEN CIRCUIT VOLTAGE: (690.7) 40.4 V SYSTEM OPERATING VOLTAGE 305 V MAX POWER VOLTAGE 30.5 V MAX ALLOWABLE DC VOLTAGE 600 V SHORT CIRCUIT CURRENT 8.95 A SYSTEM OPERATING CURRENT 8.42 A SHORT CIRCUIT CURRENT (690.8(A)(1)) 11.19 A SYSTEM SHORT CIRCUIT CURRENT 11.19 A 200A MAIN 100 AMP CONDUIT CONDUCTOR NEUTRAL PANEL � RELOCATED NONE LOCKABLE POWER -ONE: HOT BREAKER SUN RUN BLADE TYPE PVI-3.0-OUTD-S-US-A (240V) BUSSED 3 METER AC DISCONNECT 3000 WATT INVERTER 4 3 3 (2) 4 AWG THHN/THWN-2 3 0_ — o (1) 8 AWG THHNrrHWN-2 ` O--- WITH 690.35. 4. MODULES CONFORM TO AND ARE #10 SS EXTERNAL TOOTH LOCK(STAR)WASHER MODULE FRAME OR RAIL REVIEVI,LL `-' FLr CURE COMPLIANCE LISTED UNDER UL 1703. 5. INVERTER CONFORMS TO AND IS Geo FACILITY 9POUND 20A PV 250V METER SOCKET SQUARE D DUAL MPPT TRACKERS STRING BREAKER AT 125A CONTINUOUS & DU221 RB COMBINER & LOAD RATED DC 8.95 AMPS MODULE SHORT BOTTOM OF 240V METER 3R, 30A DISCONNECT AND AFCI BUSBAR 200A, FORM 2S 120/240VAC CIRCUIT CIRCUIT (690.8 (a) & 690.8 NOTES TO INSTALLER: 1. 376 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE. 2. ADD 20 AMP PV BREAKER TO EXISTING SUB PANEL. 3. ATTACH INVERTER TO THE TOP LUGS OF THE SUN RUN METER BASE. 4. REMEMBER TO LEAVE UTILITY -SIDE POWER ON TO THE SUN RUN METER WHEN YOU LEAVE THE SITE. THE RED "POWER ON" LIGHT ON THE COMMUNICATION COLLAR WILL REMAIN ON CONSTANTLY. (INSIDE OR FRONT OF PANEL) JUNCTION BOX 2 OR EQUIVALENT r-1 PV MODULES REC SOLAR: REC255PE(BLK) +'�/ (10) MODULES `tt'' (1) STRING OF (10) MODULES CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (2) 10 AWG PV WIRE NONE (1) 10 AWG BARE COPPER 2 3/4" EMT OR EQUIV. (2) 10 AWG THHNfTHWN-2 NONE (1) 8 AWG THHN/THWN-2 3 3/4" EMT.OR EQUIV. (2) 10 AWG THHN/THWN-2 (1) 10 AWG THHNITHWN-2 (1) 8 AWG THHN/THWN-2 4 1-1/4" EMT OR EQUIV. (2) 4 AWG THHN/THWN-2 (1) 4 AWG THHN/THWN-2 (1) 8 AWG THHNrrHWN-2 GROUNDING DETAIL ELECTRICAL NOTES: 1. PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2011 NEC. 2. ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH 2011 NEC. CUPERTINO 3. PHOTOVOLTAIC SYSTEM IS #1Od4SSLOCK NUT F BUIlding ©epa UNGROUNDED. NO CONDUCTORS 'M ARE SOLIDLY GROUNDED IN THE ` INVERTER. SYSTEM COMPLIES WITH 690.35. 4. MODULES CONFORM TO AND ARE #10 SS EXTERNAL TOOTH LOCK(STAR)WASHER MODULE FRAME OR RAIL REVIEVI,LL `-' FLr CURE COMPLIANCE LISTED UNDER UL 1703. 5. INVERTER CONFORMS TO AND IS 10AWGBARECU VNRE #10 -24 x 314' SS HCS BOLT i ��?fedjlf LISTED UNDER UL 1741. SS SET SCREW INCLUDED 6. ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. LAY-IN Dun. RRAATMED� 8.95 AMPS MODULE SHORT (TIN PLATED CU) CIRCUIT CURRENT. O 13.98 AMPS DERATED SHORT CIRCUIT CIRCUIT (690.8 (a) & 690.8 (b)). NOTE: REMOVAL OF PAINT IS NOT NEEDED PER UL 1703.11.3 AND 1703.11.4 SUNRUN, INC. CA CL #750184 23002ANKERROAD,UNITF,SANJOSE,CA95131 PHONE 408 740.3082 DESIGNER: REGALADO SUNRUN PROJECT NUMBER: BUDARAJU RESIDENCE ELECTRICAL PV -02 REV: A sunrun FAX408-894-9294 _ BUDARAJU (102R-882BUDA) 11882 SHASTA SPRING CT, CUPERTINO, CA 95014 _ 8/5/2014 DRAFTER: OEPOMO THREE LINE DIAGRAM 120/240 VAC # CONDUIT SINGLE PHASE SERVICE NEUTRAL GROUND 1 NONE (2) 10 AWG PV WIRE SUNRUN (1) 10 AWG BARE COPPER 2 3/4" EMT OR EQUIV. METER #: 100A (1) 8 AWG THHN/THWN-2 3 OPGE 1005145724 SUB PANEINSTALLED (1) 8 AWG THHN/THWN-2 UTILITY 1-1/4" EMT OR EQUIV. EXISTING (1) 4 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 GRID 200A MAIN 100 AMP PANEL RELOCATED HOT- BREAKER BUSSED 3 SUN RUN 4 METER LOCKABLE BLADE TYPE 3 AC DISCONNECT oho FACILITY I LOADS I V V 50A SUB _ 20A PV 250V METER SOCKET SQUARE D FEEDER BREAKER AT 125A CONTINUOUS & DU221 RB BREAKER BOTTOM OF 240V METER 3R, 30A BUSBAR 200A, FORM 2S 120/240VAC POWER -ONE: 3 PVI-3.0-OUTD-S-US-A (240V) /2- 3000 3000 WATT INVERTER o ---ego DUAL MPPT TRACKERS STRING JUNCTION BOX COMBINER & LOAD RATED DC OR EQUIVALENT DISCONNECT AND AFCI CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (2) 10 AWG PV WIRE NONE (1) 10 AWG BARE COPPER 2 3/4" EMT OR EQUIV. (2) 10 AWG THHN/THWN-2 NONE (1) 8 AWG THHN/THWN-2 3 3/4" EMT OR EQUIV. (2) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 4 1-1/4" EMT OR EQUIV. (2) 4 AWG THHN/THWN-2 (1) 4 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 _ 1 PV MODULES REC SOLAR: REC255PE(BLK) (10) MODULES (1) STRINGS OF (10) MODULES C PERTINO Suilc,,,g Depart -hent } OCT s.< REVIEWED FOR COo- COMPLIANCE Reviewed By. SUNRUN, INC. 2300ZANKERROAD,UNITF,SANJOSE,CA95131 DESIGNER: REV: A CL#750184 PHONE 40&74&082 REGALADO SUNRUN PROJECT NUMBER: BUDARAJU RESIDENCE THREE LINE PV -03 sunrunICAFAX 409-894-9294 DRAFTER: OEPOMO IBUDARAJU (102R-882BUDA) 11882 SHASTA SPRING CT, CUPERTINO, CA 95014 DIAGRAM 8/5/2014 t 8" , LABEL MAIN SERVICE: CEC 705.12(D) - (4) & CRC 331.2.2. 7"- 1 "- 1„ CAUTION: } LABEL ALL D/C CONDUIT, RACEWAY, CABLES, ENCLOSURES EVERY TEN FEET. CRC 331.2.4 AND 2012 FC 605.11.1.4 3" 6" LABEL A/C AND D/C DISCONNECTS: CEC 690.14(C)(2) LABEL ON POI BREAKER IF OCPDS EXCEED 100% OF BUS RATING CEC 705.12(D)(7) LABEL D/C DISCONNECT, JUNCTION BOXES, COMBINER, AND DEVICES IN UNGROUNDED SYSTEMS /TRANCFCIRMFRI FSSI [:FC 690.35(F) -LETTERING SHALL BE RED PLASTIC -LETTERING SHALL BE ENGRAVED 1/2" HIGH AND WILL BE WHITE LETTERING ON GREEN OR RED PLASTIC C E PERTINO pB CONIPLIANCE LABEL D/C DISCONNECT CEC 690.17 SUNRUN, INC. 2300ZANKERROAD,UNITF,SANJOSE,CA95731 DESIGNER: REV: A CA CL#750184 PHONE 406.74&3062 REGALADO SUNRUN PROJECT NUMBER: BUDARAJU RESIDENCE SIGNAGE PV -04 sunrun FAX 406-694-9294 I DRAFTER: OEPOMO BUDARAJU (102R-882BUDA) 11882 SHASTA SPRING CT, CUPERTINO, CA 95014 8/5/2014 -LETTERING SHALL BE RED PLASTIC -LETTERING SHALL BE ENGRAVED 1/2" HIGH AND WILL BE WHITE LETTERING ON GREEN OR RED PLASTIC PLACARD: DC DISCONNECTS, OCPD LABEL D/C DISCONNECT, JUNCTION BOXES, COMBINER, AND DEVICES IN UNGROUNDED SYSTEMS (TRANSFORMERLESS) CEC 690.35(F) LABEL A/C DISCONNECT OR POI BREAKER IS USED AS A/C DISCONNECT CEC 690.54 CAUTION: POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN t 1N1 SOLAR PANELS ON ROOF Deper E T L UV71EAED R Reviewed By SERVICE ENTRANCE INVERTER VNTH INTEGRATED AND PV BREAKER DC DISCONNECT DISCONNECT AC DISCONNECT SUNRUN, INC. 2300ZANKERROAD, UNIT F,SAN PHONE40&748-3082 DESIGNER: REGALADO SUNRUN PROJECT NUMBER: BUDARAJU RESIDENCE SIGNAGE REV: A PV -05 sunrun CA CL#750184 FAX 40"94-e2s4 BUDARAJU (102R-882BUDA) 11882 SHASTA SPRING CT, CUPERTINO, CA 95014 8/5/2014 o DRAFTER: OEPOMO