Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
14110115
CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 10166 CAROL LEE DR CONTRACTOR:COBALT POWER PERMIT NO: 14110115 SYSTEMS,INC OWNER'S NAME: MOUNTAIN VIEW,CA 94043 PHONE NO:(650)938-9574 LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL ❑ COMMERCIAL ❑ INSTALL 12 PANEL PV SYSTEM ON SFDWL ROOF TOP License Class 0( ) Lic.# 4.2D k- �p Contractor CGaV, U � Date 1 Yv I hereby affirm that I am licensed under the provisions of Chapt•r 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$24655 I have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:31623060 00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct.I agree to comply with all city and county ordinances and state laws relating WITHIN ! F PERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 1 • S FROM LAST CALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, - costs,and expen -s whic• ay accrue against said City in consequence of the granting of ,e9rmit.,As•itionally,the applicant understands and will comply Issued by: Date: 1I;2 / with al c -pc). .tree ,-gulations per the Cupertino Municipal Code,Section 9 18 RE-ROOFS: Si!rat. Date ( All roofs shall be inspected prior to any roofing material being installed.If a roof is installed without first obtaining an inspection,I agree to remove all new materials for inspection. • OWNER-BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER I,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) I,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I •quipment or dam/' es which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined ' fr ' Area Air I trity Management District I performance of the work for which this permit is issued. will maintain compliance the • pe :no • cipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety • Date:l! ��iV permit is issued. / I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,I CTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct.I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9 18. Signature Date \ ,..„. � ALTERNATIVE ENERGY PERMIT APPLICATION � t COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION �� 10300 TORRE AVENUE••CUPERTINO, CA 95014-3255 °\ (408)777-3228• FAX(408)777-3333•buildinq(a)cupertino.orq \ CUPERTINO PROJECT ADDRESSS tD` ^ ( ø -ot D• , n APN# 61(.0 23 n4VIu .W OWNER NAME ( CONTACT NAME \ / STREET ADDRESS ff \rnotV ( 1 I1wiAEt\vA 674A"r3FAX ❑ OWNER 0 OWNER-BUILDER 0 OWAGENT NACTOR0 CONTRACTOR AGENT 0 ARCHITECT 0 ENGINEER 0 DEVELOPER ❑ TENANT CooRACTO\t„ ` _ - m � LICENSE Mr LICENYE BUS.LIC# CrApY Na \-- ! � %NlfAA, krOi I CCA''-J - cn R-901 13v"v t 4/1A 1 ,S O ST• ! ES j CITY, TATE,ZIP ` n (, Prw)c(u/-A -11(1,ittA( Q� �M/--e Cn(1� ,. v l ���v llll���[�j "I'� ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS.LIC# COMPANY NAME E-MAIL FAX STREET ADDRESS � CITY,STATE,ZIP PHONE USE OF �GCJ JFD or Duplex 0 Multi-Family PROJECT IN WILDLAND PROJECT IN STTRUCTURE. ( ❑ Commercial URBAN INTERFACE AREA 0 Yes 0 No FLOOD ZONE ❑ Yes ❑ No •�,yOLAR PANELS !Y 0 ELECTRIC VEHICLE CHARGING STATION 0 SOLAR WATER HEATING 0 OTIILR: FOR SOLAR PANELS: ll NUMBER OF PANELS/UNITS: ,1..., 6KILOWAA1 TTS(COMMERCIAL ONLY): , T Vi ALU/ N:' DESCRIPTION OF WORK rIpti `-`] \ i Jni 1 C ,, �\I I D p IV r U` 7 rf CU/k 06/Akpk C ,C,- CEIVED$ r To m.x�E '= @; '+ ' ma RE ovog By my signature below,I certify to each of the follow' : I am the property owner or authorized agent to act on the property owner's behalf. I have read this application and the informati. I h• e provided is co I have read the Description of Work and verify it is accur te. I agree to comply with all applicable local ordinances and state laws re:ting to .. . ••const ,n. I authorize representatives of Cupertino to enter the abo -iden Tied property for inspection purposes. � I L Signature of Applicant/Agei11: /' l 7�;#, / Date: PPLEME AL INFORMATION REQUIRED h * OFkTCEt7SE ONJ ,4 Vxz aQ'WW r �'- ❑ OYER THJiCOUNTERh �._: y- lz F.x T .EXPRESS 4 h Uvte. `"r4, - .,. >U STAI ARD a_x c .." ,,' Y mizRA.-10; ❑ LARGE " r y;: - 1 P VApp_2011.doc revised 03/16/11 CITY OF CUPERTINO FEE ESTIMATOR—BUILDING DIVISION Joel ADDRESS: 10166 carol lee dr DATE: 11/20/2014 REVIEWED BY: Mendez APN: BP#: *VALUATION: $24,655 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY PENTAMATION USE: SFD or Duplex PERMIT TYPE: SOLAR-RES WORK install 12 panel pv system on sfdwl roof top SCOPE 1 1:11'-::“:44Tri!:LP:':AdigaMINORMOSTMeitlilaiketti= kc:/,. f Farr Chet k Plumb Plant t"/In/ ; I I him' Plum("heck Much Pe.',mit Fee_ Plumb Permit Fee: t let Permit Pee ()him Malt Irl/I Other Plumb lnsp. tlaet i Iec. „sr.- m Ie hum. [eh Plumb. Insp. Fee: I lec. imp fee: NOTE:This estimate does not include fees due to other Departments(i.e.Planning,Public Works,Fire,Sanitary Sewer District,School District,etc.). These fees are based on the preliminary information available and are only an estimate. Contact the Dept for addn'l info. FEE ITEMS (Fee Resolution 11-053 Elf 7/1/13) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 1 # Alternative Energy System Suppl. PC Fee: ® Reg. 0 OT 0.0 hrs $0.00 $236.00 1PHOTOVRES Photovoltaic System PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Fee:® Reg. 0 OT 0,0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 t.'ons rtic lion .Tax: t;i11lint',trail ye.' :ce: 0 Work Without Permit? 0 Yes 0 No $0.00 Advanced Planning Fee: $0.00 Select a Non-Residential 0 Building or Structure 0 F e,S Strong Motion Fee: IBSEISMICR $3.21 Select an Administrative Item Bldg Stds Commission Fee: 1BCBSC $1.00 .A $4.21 $236.00 �� ' To AUFEE: °� $240.21 Revised: 10/01/2014 Provide Weather Resistant Labels Per Scope of Work CEC&Local Jurisdiction Requirements To Install a Photovoltaic System For an Existing Residence See Sheet 2 of 8-1 Run DC Lines in Watertight Metallic Conduit I For PV Array Layout on Roof and in Eaves,T Paint to Match Existing System Consist of the following: Yp g N Y (Where Visible).All DC Wires to be Type THWN-2 -(12) SPR-X21-345 Solar Panels �IVED P.I'c� +✓rtL.,.ine -(1)SolarEdge SE3800A-US Inverter -(1)Square D Q0200TR AC Disconne t ;in,:\,, 2 0 2014 Existing Residence Project Data C©MM�} 1�D ....,.0, ME D -`kr''-oject Location - 10166 Carol Lee Drive,Cupertino CA 95014 BUILDING DIVISION -CUPER i"i ?O APP ® ® A.P.N. -316-23-060 (County of Santa Clara) I Provide Weather Resistant Labels Per This Stt of plans and specifications MUST kept at the CEC&Local Jurisdiction Requirements '{ job site duri ig construction. It is unlawful to make changes or alterations on same, or t0 deijate I ect Description - Solar Photovoltaic System Mount Inverter,AC and DC Disconnects on g Interior Wall of Garage therefrom, without approval from the Buil�inc OffiCplicable Codes - California Electrial Code 2013 Edition �� The Stampin of this plan and specifications l SHALL( MOT National Electrical Code 2011 Edition v / be held to permit or to be an approval of 1-1-., violation (Article 690-Solar Photovoltaic Systems) t 0 of any provisi� any City Ordinance or St ite L . . 20 WalkwayFETWIT --.�� ��Project Notes t7 ' 1.Unwounded Photovoltaic System E. I 01 I 2.All Work to be Performed to the Applicable Building Code. I Applicable Code(s): -National Electrical Code 2011 Edition(Article 690) I 3.Attached Documents Denote PV System Configuration. 00 O O I / I Cobalt Power Systems to Provide Complete Installation and PV tem J Operational Sys • Driveway ED E y ,•.'"-----'7f--, Sheet Index �11= r1�� I Sheet 1 -Site Plan t'M..i117,4 13u�ldrt; 1 ...... Sheet 2-PV Array Layout d I �� Dea f ( Sheet 3-Elevation Details kF ��`.g 2 0 2014 t.._ _yam! ��V:d Sheet 4-Mounting Detail ® Sheet 5-Mounting Detail tiE EWEIJ I:OR CODE COMPLIANCE — — — — — — Property Line — — — — — — — Sheet 7-System ScheSheet 6-PV Array matic e k rv'e4ro c Ly %v ,a�jq7 New 125A Service Entrance Panel Sheet 8-System Schematic and PG&E Meter ,s ' f PLAINS _ Provide Weather Resistant Labels Per . n CHECKED Inn CEC&Local Jurisdiction Requirements _ 4/ w ting Roof 4:12 Pitch or ;an Legend llA'EE I� Z��T -'-� Hori .n.Mat'1:Comp Shingle Project Gopal Chotani Photovoltaic System //� N SE -Service Entrance Panel ANNIN' D Address 7' ii- -Roof PV Array, 10166 Carol Lee Drive, Cupertino CA 95014 ti (12)S Mounted rSPR-X21-345 DATE sss Maude Ave. Date Drawing Title Rev J i _u Tel View,CA 94043 °�. Mount Modules Flat and Parallel to Existing Roof Site Plan Tel 650-938-9574 Nov 17,2014 Site Plan 1 a' Total Area 215 sq ft,Total Weight 610 lbs BLDG. DEP*: 3/32"_ , „ - a � Fax 650-938-9573 Scale: — 1 0 1 I-i POWER SYSTEMS INC. Nµµ,cobaltpower.com Sheet Signed�� 2.8 lbs/sq ft,See Sheets 2 and 3 ©Cobalt Power Systems,Inc. 1 of g G L J -1 Ridge N ®\ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ V \ \ \ \ \ \ \ \ \ \ \ NW 1100.- \ \ \ \ \ \ \ `� \ cs \ \ `r' \ \ ;" 1-1 1-2 \ \ \ V \ \ \ \ ) \ " ® 1_3;: \ \ \' \ \ BB 3 of 8 / I• I / / / 0 0 or'% Al Existing Roof 4 of 8 Matti: Comp Shingle PV Modules to be Mounted Flat and Parallel to Plane of Roof \ I \ \ Projection Above Existing , \ Existing Ridge Beam Roof 10"Typ .. \ Lidai AtAlt I` TTTT -'-\-----------'-' Ra.I I Existing 2x6 Collar Ties Existing 2x6 Roof Rafter Elevation Above Roof First Story- Section AA Scale:NTS Existing Roof 1A2 Mat'1: Comp Shingle 5� of8� / PV Modules to be Mounted Flat and �( Parallel to Plane of Roof Existing Ridge Beam t'U' ��` � 1-s, up�p:11:1" e`\\ Projection Above Existing 3a ;& "__... ..... ... __ ... ___.._........._.____._ Roof 6 yp4"Ttr=tll���r-1'�, �v ,I 1 review 1t3 llF �OM,pt! B ep lsy `.:5 '7'''l " Existing 2x6 Roof Rafter Project Exterior Wall� : H"--------- �` I Exterior Wall Gopal Chotani Photovoltaic System Elevation Above Roof Second Story- Section BB Address N Scale:NTS 10166 Carol Lee Drive, Cupertino CA 95014 0 885 Maude Ave. Date Drawing Title Rev _1_1_1_1._; Mt View,CA 94043 ,_ Tel Nov 17, 2014 173 SALT Elevation Details .__..POWER SYSTEMS INC. Fax .cobaitpower Sheet Signed www.cobaltpower.com � ©Cobalt Power Systems,Inc. 3 of 8 KC .0EI L 1 . • %" SS Nut/Lockwasher,Typ. Top Clamp linakidge haw 142014 Mr.David E.Tait Pgr 5 of 11 4"x 2Y2" SS Bolt intaRidge 71R100Rol Roans*hirawattag Spans—Straclund Analysis CO3 / xx Iron Ridge PV Support Rail Photovoltaic Module and"L"Foot Bracket TaMe 4 -MO Siam 7to27 1 * WINO Osumi 11Axe.1,�1 %"X 1"SS Bolt, Exposure mph ower 10 20 30 40 60 80 70 88 90 SS Nut/Lockwasher,TypN 100 112 9977 03 7722 6644 58 Par 53 4499 4488 4343 .; 105 112 97 83 72 64 58 53 49 48 43 %"x 1" SS Bolt Gy � 110 112 97 _ 83 72 04 56 53 49 48 43 120 112 97 83 72 64 58 53 40 48 43 and Lockwasher,Typ .----'010 \ r 130 112 97 83 72 84 58 53 40 48 43 .. 140 105 07 83 72 84 58 53 49 48 43 Ez Mount 5" �� 150 98 511 _' 82 72 04 Si 63 49 48 43 Extension Post 180 82 92 81 72 64 68 63 49 48 43 170 87 87 79 71 64 58 83 49 48 43 105 112 97 83 72 84 58 53 49 46 43 11% Mounting Base and 1115 112 91 8H 72 6t Sd 53 49 48 43 EPDM Gasket 110 112 97 83 72 64 58 53 49 46 43 120 103 97 83 72 64 53 53 49 48 43 130 98 95 82 72 64 68 Ei3 49 48 43 Aluminum Flashing 1,1:C C 140 89 88 80 71 64 58 53 49 46 43 '; . 150 64 84 , 78 7U 84 58 53 49 48 43 100 M 79 78 89 63 58 53 49 48 43 Existing Roof , 170 112 04 8374 72 644 62 58 53 49 48 43 Mat'l: Comp Shinglebks 100 97 49 48 43 105 109 97 83 72 64 58 53 49 40 43 110 103 97 83 72 64 58 53 49 48 43 :12''''t2 120 915 55 82 72 84 58 53 49 48 43 ` �� t 4'3 F 130 88 88 80 71 64 58 53 49 48 43 f 140 82 82 78 70 83 58 53 49 46 43 160 77 77 78 66 68 63 49 48 43 ' ` 4,,' Ez Mount Assembly to be Bolted to 160 79 73 7s 67 6611 57 53 49 48 43 Roof Rafter with(1)5/16"x 4"Stainless 170 48 43 Steel Lag Bolt Per Mfg's Installation 9455-19441/411 Instructions.Min Embedment 3" 1 Existing 2x6 Roof Rafters @ 24"O.C. Photovoltaic Panel Mounting - Detail Al Applies to Modules 1-4 through 1-12 Straituallidhuntatiguhre.39e. ConaltingSmicsnallinadEurzettentietitess Scale:NTS -5- Attachment Notes: ii,ri,;.„'.:.,:-.. , y CUPERTINO I.Panels to be Mounted on Aluminum Rail , �`;ulldir gDC,+pc]rtrp►e-See Manufacturer's Spec Sheets for Integrated Grounding r 1 i_ a mss ` a Mounting Base and �� 2.PV Attachment to Roof Structure using%6"Lag Screws EPDM Gasket ``j r -See Detail Al r = t,.v)''_' ) , TAluminum Flashing ( .J171 u(�p�s��C , ` 3.Attachment Points every 96"O.C.,and/or kevlewea B . _-jay„ /47 `- i i ' per Manufacture's Installation Instructions ! Roof Rafteriiii\j .' 4.Torque Specifications-Unless Otherwise Specified Project -Torque all PV module racking bolts as follows: Gopal Chotani Photovoltaic System Seal Roof Penetration and Surrounding 84 in/lbs for 1/4"bolts Address N t Area with RainBuster 850 264 in/lbs for 3/8"bolts 10166 Carol Lee Drive, Cupertino CA 95014 o 885 Maude Ave. Date Drawing Title Rev fi=t y Mt View,CA 94043 1 a Perspective Ez Mount Flashing Detail+ Tel Nov 17, 2014 TS �.�c BALT MountingDetails - _!_.t _.3..... Fax 650-938-9573 Scale:NTS I—1—I POWER R SYSTEMS 1NC. www.cobattpower.com Sheet Signed�� ©Cobalt Power Systems,Inc. 4 of 8 First Story o L 1 T Top Clamp I/a" SS Nut/Lockwasher,Typ. / Page /l/ lir r�David 1E Te8ut r[ e s of xl y"x 2%" SS Bolt �x X11,100 Rea, f1 �g Sura C '" f8 Iron Ridge PV SupportRail �� and"L"Foot Bracket y Photovoltaic Ta6103-848383l1R45r11ASG asaatsia,pe71uZ7 - > "1,1i111-- Module 1art1a9 rrira936 S8aed Snail LAW /4 '' -.r1.-1',,:..VP'1' �"x 1" SS Bolt, �, ,,,� „�, 9� 10 20 30 40 !1d 80 70 80 90 ,r�+ _ fel r urr c� SS Nut/Lockwasher,Typ 100 112 87 72 64 50 5 49 48 Psi 43 105 112 97 d3 72 64 9 49 48 43 �1%'`�s� Counter Flashing 110 112 679 r+ r27 tea g 48 48 43 I 120 112 0► - 03 72 84 5d 53 a8 48 43 Mounting Base and 140 112 0 " 83 12 64 5 63 49 43 48 43 ,� EPDM Gasket /40 a2 _ 7z as 8d 53 49 48 3 180 82 18 72 84 5d 83 49 48 48 170 87 d7 78 T1 a4 bg 49 49 43 .,,a Aluminum Flashing 1a0 112 fir _ as rx s4 se ytt 4f 46 43 105 112 87 83 72 84 5d 53 48 48 43 v nw. 1111 111 07 89 72 84 59 SCI 49 4d 45 • 120 103 9T _ : 72 84 sass ; 49 48 43 Existing Roof Cogr \� I' Mat'1: CompShingle C, 139 99 ' s2 Tz 8a Get +18 48 4s 1411 d9 d9 50 71 84 53 5'3 494949 9 48 473 , 15t1 Ha 7g 7tl W 5!I 535-J Kf 49 46 4'J 180 7!1 78 78 8d 5E Si 40 48 49 170 74 74 74 87 82 52 52- MI to 48 49 , � 100 74 97 72 84 5d 53 48 49 43 Ez Mount Assembl to be Bolted to 1a5 tad 97 d3 72 G4 511 59 411 49 49 y 119 um 97 83 72 54 59 53 49 46 43 Roof Rafter with(1)5/16"x 4"Stainless le 128 45 95 d2 72 84 6d eta 49 48 43 Steel Lag Bolt Per Mfg's InstallationscategolY 17JD dd d8 d0 71 84 5tl ss 49 48 ' 140 dR 78 70 s3 50 53 49 4d 43 / '' •.--•s I: Instructions.Min Embedment 3" 160 77 ,„82 7 78 ad 82 ce 5 48 48 4g 160 77 7] 7s 67 61 57 59 49 46 43 170 to 58 ed 65 88 ...°1 8 53 49 46 43 Existing 2x6 Roof Rafters I4o._,,x+pagrlx @ 24"O.C. Photovoltaic Mounting Detail Applies to ModulesPanel 1-1 through- 1-3A2 Scale:NTS Sr,56Ognrrda�o�,s778c. �sn, .®atrt -5m Attachment Notes: I.Panels to be Mounted on Aluminum Rail C UPERTINO Mounting Base and -See Manufacturer's Spec Sheets for Integrated Grounding t ,,c1 Fi � uildirg Department EPDM Gasket '�' t r 2.PV Attachment to Roof Structure using%6"LagScrews G`_ � ,y'J s �„ Aluminum Flashing ,.ei 'Ai, - a,= � i r` See Detail Al ' f EVlttskl ; t Uh t. SUE CUPJ;PLI PVG � 3.Attachment Points every96"O.C.,and/or ` per Manufacture's Installation Instructions Reviewed By ././.17-.,,,,, Roof Rafter 1,—;...„.......-:......., 4.Torque Specifications-Unless Otherwise Specified Project Seal Roof Penetration and Surrounding GO al Chotani Photovoltaic S stem Area with RainBuster 850 -Torque all PV module racking bolts as follows: P Y 84 in/lbs for 1/4"bolts Address 264 in/lbs for 3/8"volts 10166 Carol Lee Drive, Cupertino CA 95014 A 0 Perspective Ez Mount Flashing Detail 885 Maude Ave. Date Drawing Title Rev Scale:NTS - - Mt view,CA 94043 °' I , Nov 17, 2014 1 0 B LT Tel 650 938-9574 Mounting Details - J 1 J_., Fax 650-938-9573 4 U 7 !J POWER SYSTEMS tNG• www.cobaltpower.com Sheet 8 Second Story Signed j� ©Cobalt Power Systems,Inc. 5 of 11 L J Signage/Label Legend Tag Language Material Description Location OWarning:2 Sources of Power PV Permanent Fade Resistant Material Plaques, Service Entrance Disconnect @ Adjacent Location Red Background,White Engraved Letters, Panel 3"x 4"Min.Size OCaution: Solar PV Wiring May Remain Energized Permanent Fade Resistant Material All Solar Conduit, After Disconnection During Daylight Hours Interior And Exterior — Warning:Electric Shock Hazard-DO NOT TOUCH Permanent Fade Resistant Material Service Entrance 33 TERMINALS-Terminals on Both Line and Load Panel Sides May be Energized in the Open Position Ridge n Photolvoltaic Array DC Disconnect Switch Permanent Fade Resistant Material Plaques, All DC — �/ Red Background,White Engraved Letters, Disconnects _ 3"x 4"Min.Size r O Ungrounded System Permanent Fade Resistant Material Plaques, Inverter C l C3 Red Background,White Engraved Letters, 3"x 4"Min.Size 6 Photolvoltaic Array AC Disconnect Switch Permanent Fade Resistant Material Plaques, All AC •••.....„-- Red Background,White Engraved Letters, Disconnects ./ 3"x 4"Min.Size 2 Caution:Solar PV System Installed-When Power Permanent Fade Resistant Material Plaques, Service Entrance Ois Disconnected,Solar Panels and Wiring May Red Background,White Engraved Letters, Panel(Interior and Remain Energized During Daylight Hours 3"x 4"Min.Size Exterior) I I 0 0 0 0 0 In 0 Ridge fit,, -- i ibI ° I 6 'Si 2 �a: u LC Inv D0 ® ;fir �" C`'�PERTIN� t �_ r }. wilding DeQa'tr1eni 4 xr. = -.r ti.lw 2i 2O1 L rOR CODE CC7M!}Ltr4N C 6 Keviewea 0Y. Legend u SE -Service Entrance Panel Project DC DC Disconnect PV Array Signage Gopal Chotani Photovoltaic System Scale:Y8"= 1'0" Address A- AC -AC Disconnect 10166 Carol Lee Drive, Cupertino CA 95014 0 Inv -Inverter Date Drawing Title li s 885 Maude Ave. I Rev `r ,1�€.-i._; Mt View,CA 94043 Nov 17, 2014 1 =' -� C ci B�4LT Tel PV Array Signage L J -SolarEdge Power Optimizer P400,Typ. _ POLI R SYSTEMS INC. Fax 650-938-9573 Sheet Signed www.cobaltpower.com ©Cobalt Power Systems,Inc. 6 of 8 KC 8 L J PV Panel and Rack Grounding per To PV Rail/ IronRidge UL2703 Integrated Ground Application ‘ -Reference IronRidge Installation Instructions n • II _.� \/ I. Raintight Junction Box r Gnd 1-1 1-2 1-3 1-4 1-5 1-6 1-7 1-8 1-9 1-10 1-11 1-12 , r+ri r{-- r+—:i r.,-1 ri-- ri—ri r+-i r{-� r+ r+ r+ r+ •..,\ I 7-1+ I I r----i I 1--( I I 1--T I I 1— I 1—Z 1— I I Photovoltaic Arra Strin 1 I Opt I I Opt I I Opt I I Opt I I Opt I I Opt I I Opt I I Opt I I Opt I 1 Opt I 1 Opt I I Opt I y g L_J L_J L_J L_J L_J L_J L_J L_J L_J L_J L_J L_J - (12)SunPowerSPR-X21-345 (12)SolarEdge Power Optimizer P400 (2)#10 AWG NCI PV Wire E Lt - ----J 1 Waterproof Conduit Run.Use Watertight Fittings. �` All Conductors 90°C,600VDC Wet Rated, / t Type THWN-2 or USE-2,AWG Sizes As Shown 5.�)(1)Red#10 AWG (1)Gm#10 AWG(.7) ��}f— (1)Blk#l0AWG (1)Gm#8 AWG C—_i Calculation of Electrical Parameters 1. SolarEdge Power Optimizer Pairing with SunPower PV Module SunPower Module SolarEdge P400 Electrical Characteristics Max Input Power=400W T —1 I DC 1 Min Input Voltage=8V 1 _ 1 Max Input Voltage=80V I �+— Max Input Current=10A Max Output Current=15A SunPower SPR-X21-345 PV Module Electrical Characteristics ‘(+1 I I (_\ EGC GEC -1 +1 I Max Input Power=345W-OK(less than 400W) \ l + _ `l 1 Min Input Voltage=57.3V-OK(more than 8V) Max Input Voltage=Voc+(Lowest Temp-25°C)x(Voltage Temp Coef.) 68.2V+(-7.2°C-25°C)x(-0.1674V/°C)=73.6V-OK(less than 80V) �� SolarEdge (� Max Input Current=6.39A-OK(less than l0A) To Sheet 8 Max Output Current=(Total String Power)/(Fixed String Voltage) Ground GEC per%6'Stainless Steel Ground Star Label Conductors as Shown (12 PV Modules x 345W per PV Module)/(350V)=11.8A-OK(less than 15A) Washer Connection between SolarEdge Power ..:-- __J — Optimizer and Power Rail 2. Negative and Positive DC Conductors From PV Array to DC Disconnect SolarEdge Power SolarEdge P400 Power Optimizer Max Output Current=15A Optimizer {,° ,,, Increase Isc by Factor of 1.25 per NEC=18.8A 3 [J #10 AWG,90°C THWN-2,Ampacity per NEC 310.15(B)(16)=40A 4,7° Typical Temp Range Calculation:Use Derating Factor of 0.58 Typical SolarEdge Power Optimize . f�tWIIC�It" Q� 2 Current Carrying Conductors in Conduit-No Fill Factor Derating Required and PV Module Wirin: Confi'urati s i v," t P�r�e't1 per NEC Table 310.15(B)(3)(a) (1)Power Optimizer Per PV Module'^ ) 2 li ! Therefore#10 Ampacity is 40A x 0.58=23.2A-OK(more than 18.8A) SJ� 3. Ground Conductor From PV Array to Inverter REVIEWED OR C{jpE 1.25*Isc=1.25 x 6.39A=8.0A-#10 is OK ()11/jp(t � No Temp or Fill Factor Derating Required-Not a Current Carrying Conductor levied eri BLI V� Y 4. AC Conductors From Inverter to Service Entrance Panel Project QST SolarEdge SE3800A-US-U Gopal Chotani Photovoltaic System Max Inverter Output Current=16A.Minimum Ckt Brkr=16A x 1.25=20A. N 20A Breaker and#10 AWG is OK per NEC Table 310.15(B)(16)and 240.4(D) Address 47 5. Grounding 10166 Carol Lee Drive, Cupertino CA 95014 0 Note-Unless Otherwise Specified: DC Grounding Electrode Conductor From Inverter is#8 in Conduit,#6 Outside 885 Maude Ave. Rev `r Date DrawingTitle Conduit,#4 to Uffer Ground,per NEC 250.66 -J-,j--_.i a Provide WarningLabelsperNEC and Local _J 1—— Mt View,CA 94043 .,J_l Nov 17, 2014 1 Tel Jurisdiction Requirements Equipment Grounding Conductor From Inverter is Same Size as Ungrounded -1-1i BAL System Schematic U ._1._I _}_„ Fax 650-938-9573 Conductors or Larger,per NEC 690.45,250.122 - J t POWER SYSTEMS INC. www.cobaltpower.com Sheet Signed Ungrounded Photovoltaic System g y ©Cobalt Power Systems,Inc. 7 of 8 KC L 1 From Sheet 7 EGC GEC -I +1 DC Disconnect at Inverter 18A 600VDC P/O SolarEdge SE3800A-US-U(240V)Inverter L1 O/ O /— L2 _ To PG&E d Revenue Meter N PV System AC Disconnect at Inverter 1 Inverter Lockable,Unfused,240 VAC,60A SolarEdge SE3800A-US-U(240V) SquareD QO200TR \ LI L2 N \i (3)#10 AWG New I25A Service Entrance Panel, L 1 .. 125A 125A Main Disconnect ___�Internal Inverter 240 VAC L2 I I �o- Connection 1 ' N f 71 — 1:11--.HI-1 O— + N L2 LI DC In - �� 0 O EGC OT PV Gnd 0 (3)#10 AWG 0 n LI,20A Breaker OT GEC i ' L2,20A Breaker O i i N \1 Bond PV System Ground to Gnd(EGC) Gnd(EGC) Gnd(EGC) Existing Grounding System CE �� CUPERTINO dir, � Gnd(GEC) Gnd(GEC) � 1UIi Qep nt I I Existing Grounding to %, Provide Grounding Electrode Conductor to Grounding '� Electrode ry t a F Electrode,and Equipment Grounding Conductor per —_— NEC � 690.47,250.64 and 250.122 %EV�EVIEL } t-R C�D� c, Reviewea t3 OMP�IAN Project Gopal Chotani Photovoltaic System Address V 10166 Carol Lee Drive, Cupertino CA 95014 0 885 Maude Ave. Date DrawingTitle Rev v li .....1_1...21.....i— Mt View,CA 94043 Nov 17 2014 1 c Q GALT Tel 650-938-9574 System Schematic R J Fax 650-938-9573 — t j .-.1.. l,-,/ POWER SYSTEMS INC. www.cobaltpower.com Sheet Signed ©Cobalt Power Systems,Inc. 8 of 8 KC o L 1 - SUNP1-'0=I WER X-SERIES S LAR PA\ELS MORE ENERGr C _ � , rT , -. ti.ff , a Y UNMATCHED PERFORMANCE, RELIABILITY &AESTHETICS ` ` ` SERIES r ♦ . . . ♦ ♦ k' of ia,mJ. • 21.5%efficiency Ideal for roofs where spaceNis'atva premium or __� •< . .. where future expansionrr ight,be needed. SIGNATURE'BLACK X21 -345 PANEL • Maximum performance: X21 335 PANEL Designed,to deliver the most energy to >"E HIGHEST EFFICIENCY' demanding real world conditlons7in partial shade and hot rooftop temperatures 12"3 Generate more energy per square foot -�; � • Premium aesthetics § X-Series residential panels convert more sunlight to Litt r )0.-,, `in���ll 0 SunPower®Signature Black X$enes parcels; more power per panel,'and 7 energy persc1 f.Tii 23 r"�;� jr- t u blend harmoniously into your roof The most years.3'4 elegantyour home ` ' s ig g ,g � HIGHEST ENERGY PRC ��.,,,FIION i s Y „s 3 Highyear oneperformance deters in �� tr rated .?� Produce more energy per rat`# r� `g,::.i ,��y;Ptold� �' 9 VI �7r gY , " :,, . This advantage increases over producing 21 �more ergy over the 4,t- first 25 years to meet your needs.° 1-7eu12`�te0 a 120°fo Moe Energy�, � 110% Per RateWait tt Maxeon®Solar Cells:PundameMr lly,6e#ter o , l e Engineerea for Performance designee 1'or durability j i OCi;o 0 a �''4Z ' v: year 2> • 8fl"/n Ai' E Engineered for peace of�mind= �' .( Designed to deliver consistent il-du Je-free 7 °" energy over a very long lifetime 4$ 60°k " :5 — —__ '.',;c'''' s to. ts zo zs Designed for durability/ ,0 Years a„fiuCYp,,, The SunPower Maxeon Solar Cell'is the only cell built on a solid copper foundation virtually o 1Q% ' J ?, Nuaintai s High p€tozoN , ` impervious to the corroSiol and crackingithat Power at Nigh Temps '' ia; Conventional Pane s-5 degradeo No 1 ig^t-induced:: p ci =.: — Degradation Same excellent durability as F Series panels 6 R xs , #1 Ranked in Fraunhofer d!t biIiiy test to 4 High Average Watts o p wer maintained.an Atlas 25 + rn 4% Be:ter Low Light and comprehensive PVDI Durability test t I . spec ray Resp ;se W 2Oa *',;; ... _ *._: High-Performa33ce o Ant•Reflective Gass sunpowercorp.com S U N PRIME R. X-SERIES S LAR PANELS MORE ENERGY. FOR LIFE.' : , SUNPOWER OFFERS THE BEST COMBINED POWER AND PRODUCT WARRANTY POWER WARRANTY PRODUCT WARRANTY 100% 9s iI55 2"0 .5 10 15 2, 25 Years Years More guaranteed power:95%for first 5 years,-0.4%/yr.to year 25.8 Combined Power and Product Defect 25 year coverage that includes panel replacement costs.9 ELECTRICAL DATA ' OPERATING CONDITION AND MECHANICAL DATA X21-335-BLK X21-345 Temperature -40°F to+185°F(-40°C to+85°C) Nominal Power12(Pnom) 335 W 345 W Wind:50 psf, 2400 Pa,245 kg/m2 front&back T- +5/ 0 Max load Snow: 1 12 psf,5400 Pa,550kg/m2 front Power Tolerance +5/-0/a +5 -0% Impact Avg.Panel Efficiency" 21.1% • 21.5% 1 inch (25 mm)diameter hail at 52 mph(23 m/s) resistance ;.... Rated Voltage(Vmpp) 57.3 V 57.3 V Appearance Class A+ Rated Current(Impp) 5.85 A 6.02 A • Solar Cells 96 Monocrystalline Maxeon Gen III Cells Open Circuit Voltage(Voc) 67.9 V 68.2 V Tempered Glass High Transmission Tempered Anti-Reflective Voltage Short-Circuit Current(Isc) 6.23 A 6.39 A Junction Box IP-65 Rated Maximum System Voltage.... 600 V UL; 1000 V IEC yConnectors MC4 Compatible MaximumFuse Series 20 A � ------- - ---__._.. _. ... . .._ _. . ._ �__.... .. Frame Class 1 black anodized,highest AAMA Rating Power Temp Coef (Pmpp) -0.30%/°C Weight 41 lbs(18.6 kg) Voltage Temp Coef (Voc) 167.4 mV PC Current Temp Coef. (Isc) 3.5 mA PC TESTS AND CERTIFICATIONS REFERENCES: Standard tests UL 1703,IEC 61215, IEC 61730 1 All comparisons are SPR-X21-345 vs.a representative conventional panel:240W, Quality tests ISO 9001 2008, ISO 14001:2004 approx.1.6 m2,15%efficiency. EHS Compliance RoHS,OHSAS 18001:2007,lead-free 2 PVEvolution Labs"SunPower Shading Study,"Feb 2013. Ammonia test IEC 62716 3 Typically 8-10%more energy per watt,BEW/DNV Engineering"SunPower Yield Report," Jan 2013,with CFV Solar Test Lab Report#12063,Jan 2013 temp.coef.calculation. Salt Spray test IEC 61701(passed maximum severity) 4 SunPower 0.25%/yr degradation vs.1.0%/yr cony.panel.Campeau,Z.et al."SunPower PID test Potential-Induced Degradation free: 1000V 10 Module Degradation Rate,"SunPower white paper,Feb 2013;Jordan,Dirk"SunPower Available listings CEC,UL,TUV,MCS Test Report,"NREL,Oct 2012. 5"SunPower Module 40-Year Useful Life"SunPower white paper,Feb 2013.Useful life is 99 out of 100 panels operating at more than 70%of rated power. 6 Higher than E Series which is highest of all 2600 panels listed in Photon Intl,Feb 2012. ° / —{ 7 1%more energy than E-Series panels,8%more energy than the average of the top 10 " panel companies tested in 2012(151 panels,102 companies),Photon Intl,Mar 2013. ° 8 Compared with the top 15 manufacturers.SunPower Warranty Review,Feb 2013. ° 9(146 r)Y1 9 Some exclusions apply.See warranty for details. ° o/ 77.-----11/71-11 WI ti[9] 10 X-Series same as E-Series,5 of top 8 panel manufacturers were tested by Fraunhofer ° ISE,"PV Module Durability Initiative Public Report,"Feb 2013. 11 Compared with the non-stress-tested control panel.X-Series same as E-Series,tested in t Atlas 25+Durability test report,Feb 2013. —/ 12 Standard Test Conditions(1000 W/m2 irradiance,Mt 1.5,25°C). 4E n' [1,B1inl l 1559mm " ° 13 Based on average of measured power values during production. ; [6?.4in] See http://www.sunpowercorp.com/fads for more reference information. For further details,see extended datasheet:www.sunpowercorp.com/datasheets Read safety and installation instructions before using this product. 0 April 2013 SunPower Corporation.All rights reserved.SUNPOWER,the SUNPOWER logo,MAXEON,MORE ENERGY.FOR LIFE.,and SIGNATURE are trademarks or registered trademarks of SunPower s u n powercorp.com Corporation.Specifications included in this dotosheet are subject to change without notice. Document#504828 Rev A/LTR_EN 4. solar - • • rr, CC W SolarEdge Single Phase Inverters CSC For North America W SE3000A-US/ SE3800A-US/ SE5000A-US/ SE6000A-US/ SE7600A-US/ SE10000A-US I SE11400A-US „,.„:r„, •. .,,,:?,:•:u:.--;,,',.,,-,-,• -,,,,N.,,,,,,,,,,,,,,,,„,,,,,, ,•$,„ . it a •a solar - 9 0 a aw. Single Phase Inverters for North America SE3000A-US I SE3800A-US I SE5000A-US i SE6000A-US I SE7600A-US/SE10000A-US I SE11400A-US i SE3000A-US . SE3800A-US i SES000A-US SE6000A-US.i SE7600A-US SE10000A-US I SE1.1400A-US OUTPUT 9980 @ 208V i Nominal AC Power Output I 3000 I 3800 1 5000 6000 7600 1 11400 I VA 10000®240V • . ° , • ! ! @ 10800 @ Max.AC Power Output 3300 • 4150 i 54000 4 6000 8350 1 12000 i VA ; 545 ®2208V 0V 10950®2208V 40V 1 , 1 . , AC Output Voltage Min.-Nom.-Max.ii! I i , ! ..• - - / - V - 183-208-229 Vac • . . AC Output Voltage Min.-Nom.-Max.(1) I I ; V I / 1 l V V I V 211-240-264 Vac I ; • AC Frequency Min.-Nom.-Max.I'l 1 59.3-60-60.5(with HI country setting 57-60-60.5) . Hz • • , ' • i 42 @ 208V 48®208V I . Max.Continuous Output Current 12.5 I 16 , , 42' 25 32 @ 240V I 4.7. i5 . A ! 21®240V , , GFDI I 1 A . , . .; • Utility Monitoring,Islanding Protection,Country Configurable Thresholds Yes 1 Yes INPUT T -- Recommended Max.DC Power'') 3750 4750 6250 7500 i 9500 12400 i 14250 I W Transformer-less,Ungrounded Yes ' . . . • ,„ „ Max.Input Voltage 500 1 Vdc , Nom.DC Input Voltage325 @ 208V/350 @ 240V Vdc . 1 16.5®208V I Max.Input Currento! 9.5 I 13 I 15.5 e 240V 18 23 33 @ 208V I 34.5 . Adc Max.Input Short Circuit Current 45 , Adc . ' . . , . Reverse-Polarity Protection Yes , • . • • . . • . . Ground-Fault Isolation Detection 60Oko Sensitivity , I Maximum Inverter Efficiency 97.7 ! 98.2 ! 98.3 98.3 1 98 98 98 • % . ( , , 97.5 98 97.5®208V 97 @ 208V I • CEC Weighted Efficiency 97.5 97.5 97.5®240V 1 97.5 i % 98 @ 240V , i - Nighttime Power Consumption <2.5 -- <4 w . .... . , ADDITIONAL FEATURES Supported Communication Interfaces RS485,RS232,Ethernet,ZigBee(optional), . • . Revenue Grade Data,ANSI C12.1 Optional , , . Rapid Shutdown-NEC 2014 690.12 Functionality enabled when SolarEdge rapid shutdown kit is installed!s! STANDARD COMPLIANCE , .Safety UL1741,UL16998,UL1998,CSA 22.2 . . ' Grid Connection Standards IEEE1547 . . . . ' , . • Emissions FCC partly class B INSTALLATION SPECIFICATIONS ..., . AC output conduit size/AWG range , 3/4"minimum/16-6 AWG „ 3/4"minimum/8-3AWG 1 , DC input conduit . size/#of strings/ 3/4"minimum/1-2 strings/16-6 AWG 3/4"minimum/1-2 strings/14-6 AWG AWG range , • Dimensions with Safety Switch 30.5 x 12.5 x 7/ . . 30.5 x 12.5 x 7.5/ ' in! 303 x 12.5 x 10.5/775 x 315 x 260 -(HxWxD) 775 x 315 x 172 775 x 315 x 191 mm , . Weight with Safety Switch 51.2/23.2 54.7/24.7 . 88.4/40.1 . lb/kg Cooling Natural Convection Fans(user replaceable) . ; . Noise <25 . <50 . : dBA Min.-Max.Operating Temperature -13 to+140/-25 to+60(-40 to+60 version availablelt) : *F/'C , Range . Protection Rating NEMA 3R • , . , , . a)For other regional settings please contact SolarEdge support. l'n Limited to 125%for locations where the yearly average high temperature.above 77'F/25'C and to 135%for locations where its below 77'F/25'C. For detailed information,refer to httpl/www.solaredge.bsifiles/odfs/inverter dc oversizine euide.odf A higher current source may be used;the inverter will limit its input current to the values stated. Revenue grade inverter P/N:SExxxxA-US000NNR2 Rapid shutdown kit P/N:5E1000-RSD-51 (s)-40 version P/N:5ExxxxA-USO5ONNU4 t,,,,i-p,T ;,,' 7:; ,' , .,t4,,,, ''' • ''''l • ' - elf) •:"•)* 51.111SPE RoH„,..,,'....7..E.,-. SolarEdge Technologies,Inc,All rights reserved.SOLAREDOE.the SolarEdge logo.OPTIMIZED BY SOLAFiEDOE .-" ltl.'''-'-„ l'"•---ll"-7.--,-----,,,,--,,t,,-...,--..., are trademarks or registerd trademarks Of SotarEdge Technologies,Inc,All other trademarksmentioned herein are trademarks of their respective owners.Date:07/2014.11.0T.Subject to change without nonce.