Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
14120025
CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 1091 MILKY WAY CONTRACTOR:SUN WORK PERMIT NO: 14120025 RENEWABLE ENERGY PROJECTS OWNER'S NAME: MURGAI VISHAL&SHALINI 477 VALLEY WAY DATE ISSUED: 12/04/2014 OWNER'S PHONE: 4082533540 MILPITAS,CA 95035 PHONE NO:(650)520-9918 15Y LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL 0 COMMERCIAL INSTALL 17 PANEL PV SYSTEM ON SFDWL ROOF TOP License Class 4(C- Lic.# 6121,1 32. 4.42 t✓ w ,,,, te,towsv y KW Contractor Date I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$15250 P I have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:36219005 00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT -1' I'1 S I WORK IS NOT STARTED correct.I agree to comply with all city and county ordinances and state laws relating WIIII 180 DAYS OF 'ERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 1 ;YS FRO i AST CALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the Issued by: Date: 2 11+ granting of this permit. Additionally,the applicant understands and will comply 41 with all non-point source regulations per the Cupertino Municipal Code,Section 9 18. RE-ROOFS: Signature Signature %^' Date 2lw7l y All roofs shall be inspected prior to any roofing material being installed.If a roof is installed without first obtaining an inspection,I agree to remove all new materials for inspection. ❑ OWNER-BUILDER DECLARATION Signature of Applicant: Date. I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER I,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) I,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sections 25505,25533,and 25534. / Section 3700 of the Labor Code,for the performance of the work for which this Owner or authorized agent .4— Date: (2/4/ `'t permit is issued. I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's CONSTRUCTION LENDING AGENCY Compensation laws of California. If,after making this certificate of exemption,I become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct.I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9 18. Signature Date • \000.4,,, ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION nQj 5`'9S: 10300 TORRE AVENUE•CUPERTINO,CA 95014-3255 \'V 4 . ` (408)777-3228• FAX(408)777-3333•buildinq cupertino.orq a CUPERTINO \ PROJECT ADDRESS t(J^q 1 /-1. 1 /y 1.-..)7/ Dq PN# 2 1 9 005-, , OWNER NAME l PHONE yO c 33- 5�p I E-MAILf7GCrJ" STREET ADDRESS t_ CITY, STATE,ZIP FAX CONTACT NAME J PHONE ibsy E-MAIL xe.A,e., Volt S?a -9g,V le S e,1 .H,,,,.o rtr ,a,) STREET ADDRESS CITY,STATE,ZIP FAX y 7-) l/�llrr.� t-./u� �// r-0,0,47.5 CA 9 so°35 (65 n, C2-0-91,P ❑ OWNER 0 OWNER-BUILDER 0 OWNER AGENT �/CONTRACTOR 0 CONTRACTOR AGENT 0 ARCHITECT 0 ENGINEER 0 DEVELOPER 0 TENANT CONTRACTOR NAME , LICE NUM R LICENSE TYPELBUS.LIC# �...L.,F,et, �e.o-..n6/C. 6...3 A"jec-1 COMPANY NAM W E-MAIL FAX 420 STREET ADDRESS CITY,STATE,ZIP PHONE 64/1-4i 6/ c0 i 4KC.IL ...- ARCHITECT/ENGINEER ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS.LIC# COMPANY NAME E-MAIL FAX STREET ADDRESS- CITY,STATE,ZIP PHONE USE OF 52,SFD or Duplex 0 Multi-Family PROJECT IN WILDLAND PROJECT IN STRRUUCTURE: ❑ Commercial URBAN INTERFACE AREA 0 Yes 0 No FLOOD ZONE 0 Yes 0 No IQ SOLAR PANELS 0 ELECTRIC VEHICLE CHARGING STATION 0 SOLAR WATER HEATING 0 OTHER: FOR SOLAR PANELS: NUMBER OF PANELS/UNITS: -,,, KILOWATTS(COMMERCIAL ONLY): TOTAL VALUATION: f 5-2 co , c,,,.O� 17 5/,tiZo DESCRIPTION OF WORKn �, 412 0 las; 5,44... 74...6 ✓om6� ao'1t,� rV Sym RECEIVED BY By my signature below,I certify to each of the following: I am the property owner or authorized agent to act on th owner .ehalf. I h. e read this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply wit all applicable local ordinances and state laws relating to building construction. I authorize representatives of Cupertino to enter the above-identified property for inspection purposes. Signature of Applicant/Agent: —....."---- Date: 12 / N/ f el SUPPLEMENTAL INFORMATION REQUIRED , ,; ovoCE USE;dNLY` ,,i;,;_ t❑ OVER THE-COUNTER' Y , : F,c EXPRESS ' Ut.. t It*hn DD rm U y * z dl ❑ LAicE'' z Z .. . MAJOR s PVApp_2011.doc revised 03/16/11 CITY OF CUPERTINO Ajhoolive2FEE ESTIMATOR- BUILDING DIVISION ADDRESS: 1091 milky way DATE: REVIEWED BY: Mendez , 1' -tp. ti APN: BP#: *VALUATION: $15,250 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY PENTAMATION USE: SFD or Duplex PERMIT TYPE: SOLAR-RES WORK install 17 panel pv system on sfdwl roof top 4.42 kw SCOPE 4 Plumb. Phut Cheri. J ',Phi: Pet uri Fee: Piece!,. Permit Pee 1 e: 0::ch. jeep n OtherPlumb fuse n Outer LLC Le:. IFIsI:>. n isleImp. l e' Plumb. Imp. Tee- 1ie,:. Imp I'ee NOTE: This estimate does not include fees due to other Departments(Le.Planning,Public Works,Fire,Sanitary Sewer District,School District,etc.). These fees are based on the preliminary information available and are only an estimate. Contact the Dept for addn'I info. FEE ITEMS (Fee Resolution 11-053 Eff 7/1/13) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 1 # Alternative Energy System Suppl. PC Fee: 0 Reg. 0 OT 0.0 hrs $0.00 $236.00 1PHOTOVRES Photovoltaic System PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Fee:® Reg. 0 OT 0,0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 (]ontsti'uc/ion .7.Ia: ,1(471117/ !POI/ ee: 0 Work Without Permit? 0 Yes (J No $0.00 Advanced Planning Fee: $0.00 Select a Non-Residential 0 t ? Fees: Building or Structure 7wIllnervalionStrong Motion Fee: IBSEISMICR $1.98 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $1.00 e *04 $2.98 $236.00 TOTAL FEE:-1 $238.98 Revised: 10/01/2014 COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION -CUPERTINO PROJECT DETAILS: PROPERTY LINES: APPROVED PERMITTING AUTHORITY NOTES: This set of plans and specifications MUST be kept at the job site during construction. It is unlawful to make any ARRAY PITCH: 18.5° (4:12) chan9es or alterations on same, or to deviate therefrom, without approval from the Building Official. Iv�D ARRAY FACING: 160° (SSE) The Stamping of this plan and specifications SHALL NOT SITE LATITUDE: 37.31° (379 8'N) be held tp_permit o num" '.n approval of the violation DEC 0 4 2014 of any"provisions .41 _Ci Ordinance or State Law. TYPE OF STRUCTURE: residence TE I441ly --- MIT NO. 1 y 126C�Z ' — nerirli I�. „, ROOF CONSTRUCTION: 4:12 cross hipped, , Milky 3/4"spaced planks over 2x4" rafters, Way spaced 24"on center, 7' 6" maximum span ..-0000.. , AGE OF STRUCTURE: #years - - , ROOFING TYPE: stone-coated steel panel ['LOT YLAIvb CHECKED BY AGE OF ROOFING: 20 years /2! )ATE / 11 NUMBER OF STORIES: 1 PIAN'I" 5EPT. EXPOSURE CATEGORY: B DATE ****** BLDG. DEPT.HOUSE ACCESS REQUIRED: n0 , - , CONTACT NAME: Vishal Murgai .._ N CONTACT PHONE NUMBER: (408) 533-5401 cell AEA rvo r 'I� OUiidl jr p�"�ertment W � � ' + EVIEVVED SUR CODE COMM t�eure�ve3 Lay, � LIAs�ft;E Project Drawing CUSTOMER NAME: Murgai, Vishal SYSTEM SIZE: 4.420 kWdc-stc SYSTEM RATING: 3.400 kWac-field ` 477 Valley Way SITE ADDRESS: 1091 Milky Way, Cupertino, CA 95014 unWork Milpitas, CA 95035 MODULE TYPE AND NUMBER: REC Solar REC-260-PE BLK (17) Renewable EnergyP. ,ro' cts AUTHORITY HAVING JURISDICTION: City of Cupertino "' (650) 520-9918 INVERTER TYPE AND NUMBER: Enphase M215-60-2LL-S22 (17) CA License No. 920732 (650) 350-4331 fax DATE: 3 December 2014 DRAWING NUMBER: SW.0320.PD.A.01 SCALE: 1:240 (1 inch = 20 feet) STRUCTURAL LOAD CALCULATIONS: [As per ASCE 7-10,see Unirac design load worksheet for additional detail] Building height=12 ft Building least horizontal dimension=50 ft Risk category= II Exposure category=B Roof pitch= 18.5 degrees Roof zone location=2—end zones Effective wind area= 10.9 sf Basic wind speed= 110 mph Net design wind pressure=<12.5 psf, -34.7 psf> Existing Main Service Panel \- Adjustment factor for height and exposure= 1 Topographic factor= 1 FRONT OF HOUSE Design wind load=<12.5 psf,-34.7 psf>x 1 x 1 =<12.5 psf,-34.7 psf> 1/2"EMT conduit carrying 4, #10 AWG THWN-2 conductors(2 Deadnloadload= psf T ungrounded ac lines,ac neutral, Total design load, 0 psf ldownforce case 1 and equipment ground) Oo 0 =2.8 psf+0 psf=2.8 psf Total design load,downforce case 2 =2.8psf+.6x12.5psf= 10.3psf Total design load, downforce case 3 =2.8psf+.45x 12.5 psf+.75x0 psf=8.4 psf Total design load, uplift =.6x2.8psf+.6x-34.7psf=-19.1psf Per penetration area= 10.9 sf Point load, dead=2.8 psf x 10.9 sf=31 lbs - Array Point load,downforce= 10.3 psf x 10.9 sf=112 lbs oint load, uplift=-19.1 psf x 10.9 sf=-208 lbs of 17,260-watt Photovoltaic Modules with 17,215-watt NEMA 6 D�pal8nt grid-tie Solar Microinverters,mounted using Unirac SolarMount l � y Lag screw type=2 x(5/16"x 31/2"SS) 41'�� standard rail attached to rafters every 48"using lag screws,with - +� r Embedded thread depth=2 x 31/2"—1" 2 x 21/2 penetrations through the steel panels avoided using QuickScrews _ Rafter wood type=Douglas Fir—Larch WaAp# Stone Coat roof hooks and penetrations through the underlayment 5(1��6"lag screw withdrawal cap. =266 lbs/in sealed using a high-performance scypolymer bonding sealant RPVIEVVEL� rOR CODE COMPLIANp3tnt withdrawal cap.=5"x 266 lbs/in= 1330 lbs Reviewed By •';'r. _Rafter details=2x4",24"on center,7'6"span reir Site Drawing CUSTOMER NAME: Murgal, Vishal SYSTEM SIZE: 4.420 kWdc-stc SYSTEM RATING: 3.400 kWac-field 477 Valley Way SITE ADDRESS: 1091 Milky Way, Cupertino, CA 95014 SunWorkl Milpitas, CA 95035 MODULE TYPE AND NUMBER: REC Solar REC-260-PE BLK (17) Renewable Energy.Pr© €&s (650) 520-9918 AUTHORITY HAVING JURISDICTION: City Of Cupertino INVERTER TYPE AND NUMBER: Enphase M215-60-2LL-S22 (17) CA License No. 920732 (650) 350-4331 fax DATE: 3 December 2014 DRAWING NUMBER: SW.0320.SD.A.01 SCALE: 1:120 (1 inch = 10 feet) • 2x6"ridge board 2x4"rafters 2x6"purlin spaced 24"on center with 7,6„ I pp p- maximum span rr --j —,-:j—.--7---r---�- —r--=-r---I—_ 7—_ .I—.- T_-_r -r , . 1 T above 2x4„ I 1 I I I I ceiling joists {I� mI I 1 I I ! {I) mI T I T I p p T T I T I I II I I I I I I, II 7 ] 7 I I ist' I 7 Y ----1II ---_�-___ --_moi--_` _--_�____�__ I I I I I I I I I I I I I I I I I I I I I I I I I I I CUPERTINO 2x4"exterior walls i I ; Guildirg Department with double top I �l plates and studs l :1,, L 0 4 2014 16"on center REVIEVVED rOR CODE COMPLIANCE Reviewed By. j5 .• !/•- ;,r Framing Drawing CUSTOMER NAME: Murgai, Vishal SYSTEM SIZE: 4.420 kWdc-stc SYSTEM RATING: 3.400 kWac-field 477 Valley Way SITE ADDRESS: 1091 Milky Way, Cupertino, CA 95014 SunWork f' _ Milpitas, CA 95035 MODULE TYPE AND NUMBER: REC Solar REC-260-PE BLK (17) Renewable EnergyProjects (650) 520-9918 AUTHORITY HAVING JURISDICTION: City Of Cupertino INVERTER TYPE AND NUMBER: Enphase M215-60-2LL-522 (17) CA License No. 920732 (650) 350-4331 fax DATE: 3 December 2014 DRAWING NUMBER: SW.0320.FD.A.01 SCALE: 1:60 (1 inch = 5 feet) , jj 3S` Geocel® setting the standardrm Mt GeoGreer -. BONDING SEALANT Adheres To:Asphalt shingles,steel, concrete,EPDM,primed TPO,primed 1.PRODUCT NAME: PVC,Hypalon(black only),metal,wood, GeoGreen 4500*Roof Bonding Sealant and other common buldarg substrates 2.MANUFACTURER: Composition and Mat rial& ,:i! GEOCEL,LLC Proprietary,non-solvent technology P.O.Box 398 Elkhart,IN 46515 USA Grade:Gun grade consetency Phone:(800)348-7615 Rimer.Not required on most surfaces. Fax(800)348-7009 e:O.Ok On TPO and PVC membranewww.GeocelUSAwm GtJ[DY'' - applications,a printer isrequired. Geocel recommends using 45PTM Low Roof hook sealingto beprovided 3.IRODUCT DESCRIPTION: , VOC,TPO&PVC Perrier. GeoGreen 4500®Roof Bonding Sealant i„,; by original roofing contractor in Packaging 10 fl.oz.cm1rdge is a premium Scypofymerg I one-con ponent,proprietary,non-advent .- Colors:Black and white accordance with applicable codes 1 bonding sealant specifically designed ......�� and standards I fa ; and •me technology o500 Lirrdtatiot •Do not use on unpruned TPO or PVC Sealant results m a product that .: �� membranes knmediatey withstands ponding water5(-1, ..,... ;, •Do not use black 4500 Roof Sealant while bonding to many common roofing " on white EPDM substrates. s. •Do not use white 4500 Roof Sealant on black EPDM Product Benefits: • Appkes,adheres,and cures underwater • 2 products int-lap adhesive& ti.,-'r scrim edge sealant . • No additional adhesives or sealants needed • • Remains flexible • Works with EPDM membranes,tapes, and patches • Meets LEED&NAHB guidelines : • Safe,non-flammable,non-solvent formulation 4....,:f.1 , Basic Uses:For repakf ig and sealing x a„„' „ • /�►(�,, . -f _ S ISO around through-roof projections, _ 5E a termination points,and flashings.Also as '�""n — L. o' ,�N ,l t an EPDM lap cement adhesive or scrim a 'u, taool,seas,,,•v� l , edge sealant. j i s_i1-fli 'i'I a(tfTj'tent izEVIEWEL i-CR CODE COMPLIANCE- :eviewe3 8y _50te", •.47-‘,.,y' Attachment Detail CUSTOMER NAME: Murgai, Vishal SYSTEM SIZE: 4.420 kWdc-stc SYSTEM RATING: 3.400 kWac-field .ox rfr Valley J '�� 477 Way ._._ SITE ADDRESS: 1091 Milky Way, Cupertino, CA 95014 WorkMilpitas, CA 95035 MODULE TYPE AND NUMBER: REC Solar REC-260-PE BLK (17) Renewable Energy.P.rojerts AUTHORITY HAVING JURISDICTION: City Of Cupertino (650) 520-9918 INVERTER TYPE AND NUMBER: Enphase M215-60-2LL-S22 (17) CA License No. 920732 (650) 350-4331 fax DATE: 3 December 2014 DRAWING NUMBER: SW.00320.AD.A.01 SCALE: 1:2 (1 inch = 2 inches) Enphase M215-60-2LL-S22 Solar Microinverters (1 branch circuit of 17 in parallel) ELECTRICAL CALCULATIONS: G O O O . O O O O O O O O O O O O O [As pert the 2013 revision of the California Electrical N Code, pertinent articles cited below] ..... _ • • Module Electrical Specifications: L1 L2 • —i— Pmp= 260 W Maximum System Voltage [690.7] Vmp= 30.7 V — + — + — + — + — + — + — + — + — + — + — + — + — + — + — + — + — + Imp= 8.5 A Module nominal open circuit voltage=37.8 V 1 ci IQ L CI QI IQ 1 QI IQ L ci IQ 1 1 QI IQ sc = 9.0 V ILowest temperature on record=-7'C sc= 9.0 A Open circuit voltage temperature coeff.=-.27%/t Low temperature voltage correction coeff.= 1.09 , , Limit open circuit voltage=37.8 V x 1.09=41.2 V REC Solar REC-260-PE BLK Photovoltaic Modules (17 individual module circuits) Inverter Electrical Specifications: Pmax-ac= 215 W Maximum Circuit Current [690.8] Enphase ET10-240 trunk cable Vmax-dc= 45.0 V Module nominal short circuit current=9.0 A #10 AWG solid bare eq.ground Imax-dc= 15.0 A � Possible sustained irradiance coeff. = 1.25 Existing Murray bonded to mountingrails and module frames Vnom-ac= 240 V Limit short circuit current=9.0 A x 1.25=11.3.A 200 A Single-Phase 240 V Imax-ac= 0.90 A Main Service Panel PV Array Electrical Circuit 1 Allowable Continuous Current Waterproof Specifications: 240 Vac 2-pole Splice P 3655 W Conductor size=#10 AWG 20 A Circuit Breaker (1) max-ac= Connector V Conductor temperature rating90t J . f� r oo-dc= 37.8 V p = ISc-dc= 9.0 A Base conductor ampacity[310.15]=40 A .i Vnom-ac= 240 V Highest ambient temperature=67t Ambient temperature derating coeff. [310.15]=.58 200 A Imax-ac= 15.3 A Grouped current-carrying conductor count=2 Multiple conductor derating coeff. [310.15]= 1 Corrected ampacity=40 A x.58 x 1 =23.2 A Allowable continuous current=23.2 A x.8=18.6 A M - e — '/z" EMT conduit: #10 AWG THWN-2 line 1CUPERTp O #10 AWG THWN-2 line 2 #10 AWG THWN-2 neutral 1, ANIti ,- auiIdirq Depart-tent ® ' #10 AWG THWN-2 eq. ground 1-::17.:,,,',:, UTILITY GRID e C. t.., ti q' 2014 REVIEWED rOR CODE COMPLIB,NCf Revieweo By _1< -Y 11-477-‘-'1V Electrical Drawing CUSTOMER NAME: Murgai, Vishal SYSTEM SIZE: 4.420 kWdc-stc SYSTEM RATING: 3.400 kWac field 477 Valley Way SITE ADDRESS: 1091 Milky Way, Cupertino, CA 95014 ,;^Su W0r % �4J Milpitas, CA 95035 MODULE TYPE AND NUMBER: REC Solar REC-260-PE BLK (17) _ Renewable Energy_Projects (650) 520-9918 AUTHORITY HAVING JURISDICTION: City of Cupertino INVERTER TYPE AND NUMBER: Enphase M215-60-2LL-S22 (17) CA License No. 920732 (650) 350-4331 fax DATE: 3 December 2014 DRAWING NUMBER: SW.0320.ED.A.01 SCALE: N/A PHOTOVOLTAIC SYSTEM INTERT1E fes, -W RN N`G r�rf; PHOTOTOLTAIC SCONNECTED SOURCE CIRCUIT WIRING MAY REMAIN ENERGIZED AFTER SYSTEM DISCONNECTION DURING DAYLIGHT NOMINAL OPERATING AC VOLTAGE 240 V MAX OPERATING AC CURRENT 15.3 A For service contact SunWork Renewable Energy Projects www.sunwork.org (650)520-9918 (650) 350-4331 fax Labeling for Main Service Panel, engraved sun resistant placard mechanically attached to the front surface of the enclosure of the existing main service panel with aluminum rivets PHOTOVOLTAIC SYSTEM WARNING! SOLAR BACKIFED .:11 m.."ul''ER f IN0 INVERTS OUTPUT CONNECTION _7 DO'NOT RELOCATEOVERCURRENTL-VICE T•UJIding Dtpar ent Y Labeling for Circuit Breaker, ref1 dery outdoor sticker affixed to the deadfront face of the existing main servici i rh IVV L) s-OR C ODE COMPLIANCE f evIewei By _fir,,. Labeling Detail CUSTOMER NAME: Murgal, Vishal SYSTEM SIZE: 4.420 kWdc-stc SYSTEM RATING: 3.400 kWac field it 477 Valley Way SITE ADDRESS: 1091 Milky Way, Cupertino, CA 95014 nwO C ' fr Milpitas, CA 95035 MODULE TYPE AND NUMBER: REC Solar REC-260-PE BLK (17) Renewable Energy Projects (650) 520-9918 AUTHORITY HAVING JURISDICTION: City of Cupertino INVERTER TYPE AND NUMBER: Enphase M215-60-2LL-S22 (17) CA License No. 920732 (650) 350-4331 fax DATE: 3 December 2014 DRAWING NUMBER: SW.0320.LD.A.01 SCALE: 1:1 (1 inch = 1 inch) R 4 ENERGIZING LIFE TOGETHER REC p zg r`4 "3s �k gz & ,,ry�y gam} d il5d!�° o q vt S , • ., / / ' / ,, i / i / ' / 1 g ''':11111-;,; ''''..,:::,E INI*� �''sig� r�F� /sem J s ,/ice t' Utz If , g x Yp / .....„„,„ sl 4 Y h£ y ....,. _..,. . ._ .., ,.,„_, 4 1 „...._ . ., _... ,„.„ ,. , fi� Y v . _._:,., __ _,.. ._ . ___.. _ .._..__„...,„ _ x ,32 YS „,„:„ ‘. _. tt ... $ j .....,._ . '- ,,,,„_,,,, ////,' ':.'.'.',1 Y J,F 1 ,-.1,tI �IIsl� / "' fl/J ' - iris , 1 ��I o� `P7�____, -/ �./- - _. / ,.� �1d _ puri tF //// , _.,,,,/.. ,.. v. // h t - ' <III E i f „// { (fJJ 1 ' ' /j ti- i i r. ,ar-----�1 i s,rr..+" 4 t 4. ,3 £ r i"Y f44.... - t y' . -ri . a ;gg 'N.f 1 1 I. i ,. , ,i _ ., i '' ..z+r t . gga.»:�' , i il' ?r e 6555=0.1 o P:,551555555,- 11 3543 1506 '' , , `,�V 61 Y jQ „l a . � ±008 I co Te';, r ; rxrS �:1 s 4 ,,y � ;; 5 4 f':e T .rX-S"d 9 yow gm �6"' �iv..�.`....f.... Y ` cCu..;f'+ f T " p i .. ',• . Mounting holes TEM Ami R.E R 1 MSS -71'' el � `Wf r � i 1.77 J ,�''fk" ���y ".4R All measurements in inches `.�',' �,W' ,-n �� `�A9�',�'+��€r 3 ...,.� ^ua ? ��.: ELEC3RICALDATA @ STC REC235PE REC240PE REC245PE REC250PE REC255PE REC260PE +L �' GENERAL DATA " BLK BLK BLK BLK BLK BLK i a, �I- '.y-1 6'a� �„ 3" spy l ' -.,,f, T�z}y „IA': l' , Nominal Power-P . (W) 235 240 245 250 255 260 at it ate,`' r+,Pa p tom � ''F� s� �a-`�-. -��� � sr Watt Class Sorting-(W) 0/+5 0/+5 0/+5 0/+5 0/+5 01+5 i t' s,, r ,.-;000 iomP Nominal Power Voltage-VMPP(V) 29.5 29.7 301 30.2 30.5 30.7 z ?oda a 3 �1 a 6 zli Nominal Power Current IM,P(A) 8.06 8.17 8.23 8.30 8.42 8.50 '' I A., l" Open Circuit Voltage-Vac(V) 36.6 36.8 37.1 37.4 37.6 37.8 . �' i`°, rag AIVo,1 b 4` ' Short Circuit Current-Isc(A) 8.66 8.75 8.80 8.86 8.95 9.01 s Panel Efficiency(%) 14.2 14.5 14.8 15.1 15.5 15.8 �i� a .. `_= 41" , 4 Analysed data demonstrates that 99.7%of panels produced have current andvoltage tolerance of±.3%from nominal values. ,� 1,d a = a^a Values at standard test conditions STC(airmass AM 15,irradiance 1000 W/m',cell temperature 25°C). ' Atlow irradiance of200W/ma(Am 15and cell temperature 25°C)at least 97%of the STC panel efficiency will be achieved. a ar�i- g , eksim .f ELECTRICALDATAi NOCT REC235PE REC240PE REC245PE REC250PE REC255PE REC260PE MAXIMUM RATINGS BLK BLK BLK BLK BLK BLK a.a� .;z7t i' 13 64:04 'ax'.:u i l ' p§' Nominal Power-PMp (Wp) 179 183 187 189 193 197 �4j 4 W. 4' Nominal Power Voltage-VMPP(V) 27.5 277 28.1 283 28.5 29.0 rs a a,P y� Nominal Power Current-I (A) 6.51 6.58 6.64 6.68 6.77 6.81 4. MP, a 4 � Open Circuit Voltage Voc(V) 342 34.4 34.7 35.0 353 35.7 " �� k a , Short Circuit Current-IK(A) 6.96 7.03 7.08 7.12 7.2. 7.24 ' Y " - ,v,„;--;.A'1Nominal operating cell temperature NOCT(800 WmAM 15,windspeed 1 m/s,ambient temperature 20°Ci. ,x sy •4 aa" @ Tf� f a t�Fft6 CERTIFICATION WARRANTY MECHANICAL DATA , , 4" ` �'10yearproductwarranty. v 1 cO usE E3 25 year linea r power output warranty a_ r r` , of u (max.de cession in performance of 0.7%pa.). 4 UL1703,IEC 62716(ammonia resistance)&IEC 61701 I s ifi . a �(salt mist corrosion-severity leve l6). 31 _ , aaz �gfi " e ,,,,,n,,,,,•;,40.., c ':' a s ; n . r . REC is a leadingglobal provider of solar electricity solutions.With nearlytwo decadesof expertise,we offer sustainable,high-performing amu, ��� products,services and investment opportunities for the solar and electronics industries.Together with our partners,we create value by providing solutions that better meet the world's growing electricity needs.Our 2,300 employees worldwide generated revenues of more than NOK 7 billion in 2012,approximately USD 1.3 billion. www.recgroup.com 835 Aerovista Place,Ste 230 San Luis Obispo,CA 93401 Dir 805 704 3226 Fax 805 457 6104 ICn�_C avw,r,e; rouo.corn SunWork Renewable Energy Projects PO Box 60250 Palo Alto,CA 94306 ATTN: Reuben Veek RE: Unirac UGC-1 Clip Grounding Authorization San Luis Obispo, May 18, 2012 To Whom It May Concern: REC Solar approves the the Unirac UGC-1 product to electrically bond and ground the REC Peak Energy series module frame. Using this system meets the manufacturer requirements for bonding and grounding and will not void the warranty for installations performed in accordance with the manufacturer's guidelines. Best regards, CO„,e, C George McClellan REC Solar US LLC Technical Sales Manager SOLARMOUN1 Technical Datasheets a:'UNIRAC A HILTI GROUP COMPANY SolarMount Technical Datasheet Pub 100602-ltd V1.0 June 2010 SolarMount Module Connection Hardware 1 Bottom Up Module Clip 1 Mid Clamp 2 End Clamp 2 SolarMount Beam Connection Hardware 3 L-Foot 3 SolarMount Beams 4 SolarMount Module Connection Hardware SolarMount Bottom Up Module Clip Part No. 321001, 321002 iy • Bottom Up Clip material: One of the following extruded aluminum Bottom , - alloys:6005-T5,6105-T5, 6061-T6 Up Clip `,t-'4;•%,,,,1 • Ultimate tensile: 38ksi,Yield: 35 ksi '4„ T • Finish:Clear Anodized • Bottom Up Clip weight:—0.031 lbs(14g) Beam - = Bolt ' Allowable and design loads are valid when components are assembled with SolarMount series beams according to authorized UNIRAC documents is x r • Assemble with one'/"-20 ASTM F593 bolt, one Y4"-20 ASTM F594 r k serrated flange nut, and one IA"flat washer • Use anti-seize and tighten to 10 ft-lbs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third- party test results from an IAS accredited laboratory • Module edge must be fully supported by the beam * NOTE ON WASHER: Install washer on bolt head side of assembly. DO NOT install washer under serrated flange nut Applied.Load Average Allowable Safety Design Resistance Direction Ultimate Load Factor, Load Factor, lbs(N) lbs(N) FS lbs(N) 0 Tension,Y+ 1566(6967) 686(3052) 2.28 1038(4615) 0.662 Y t- Transverse,X± 1128(5019) 329(1463) 3.43 497(2213) 0.441 - -0-X Sliding,Z± 66(292) 27(119) 2.44 41 (181) 0.619 Dimensions specified in inches unless noted SOLARMOUNT Technical Datasheets ::'UNI RAC A HILTI GROUP COMPANY SolarMount Mid Clamp Part No.320008,320009,320019,320020,320021, 320084,320085,320086,320087,320120,320122 Bolt • Mid clamp material: One of the following extruded aluminum la �' ; alloys: 6005-T5, 6105-T5, 6061-T6 ci ;" ,,,tzfrv- • Ultimate tensile: 38ksi,Yield: 35 ksi � * ; ..'*„ • Finish: Clear or Dark Anodized . �, V . '-` Mid clamp weight 0.050 lbs(23g) . 1 ; , �� -\. • Allowable and design loads are valid when components are 4,Val:'-. C T , assembled according to authorized UNIRAC documents ' 3 • Values represent the allowable and design load capacity of a single kms, mid clamp assembly when used with a SolarMount series beam to 3 retain a module in the direction indicated �� -:_ Assemble mid clamp with one Unirac W'-20 T-bolt and one W-20 {t � 4,, ASTM F594 serrated flange nut � ?N . Use anti-seize and tighten to 10 ft-lbs of torque U. • Resistance factors and safety factors are determined according to -,r,„ � - .: part 1 section 9 of the 2005 Aluminum Design Manual and third- -, party test results from an IAS accredited laboratory Applied Load Average Allowable Safety Design Resistanc 1. DISTANCE Direction Ultimate Load Factor, Load Facto BETWEEE N MODULES lbs(N) lbs(N) FS lbs(N) Tension,Y+ 2020(8987) 891 (3963) 2.27 1348(5994) 0.66 Transverse,Z± 520(2313) 229(1017) 2.27 346(1539) 0.66- A Sliding,X± 1194(5312) 490(2179) 2.44 741 (3295) 0.621 vX Dimensions specified in inches unless noted SolarMount End Clamp Part No.320002,320003,320004,320005,320006, 320012,320013,320014,320015,320016,320017, 320079,320080,320081,320082,320083,320117, 320118,320123,320124,320173,320185,320220, • End clamp material: One of the following extruded aluminum 320233,320234,320331alloys:6005-15, 6105-15, 6061-16 g ', 0, • Ultimate tensile:38ksi,Yield: 35 ksi - : ,',-;',- 7t41.' • Finish: Clear or Dark Anodized .�; • End clamp weight:varies based on height: -0.058 lbs(26g) V ' �. : `.> d Clamp • Allowable and design loads are valid when components are ` ta,* `' ` ` 41 -44 -I assembled according to authorized UNIRAC documents , '401 (1?�A • Values represent the allowable and design load capacity of a singl- end clamp assembly when used with a SolarMount series beam to *-' I retain a module in the direction indicated s ti • Assemble with one Unirac%"-20 T-bolt and one%%20 ASTM F594 x eea` .. ;( serrated flange nut " ✓ � • Use anti-seize and tighten to 10 ft-lbs of torque a • Resistance factors and safety factors are determined according to ," '' part 1 section 9 of the 2005 Aluminum Design Manual and third- ,Y o '- party test results from an 1AS accredited laboratory A ;fid,./ • Modules must be installed at least 1.5 in from either end of a beam --►X Applied Load Average Allowable Safety Design Resistanc- ':MINIMU°'- Direction Ultimate Load Factor, Loads Facto lbs(N) lbs(N) FS lbs(N) HEIGHT __j VARIES Tension,Y+ 1321 (5876) 529(2352) 2.50 800(3557) 0.60. MODULE THIIXNESS Transverse,Z± 63(279) 14(61) 4.58 21 (92) 0.331 1 Sliding,X± 142(630) 52(231) 2.72 79(349) 0.55. Dimensions speci d , SOLARMOUNT Technical Datasheets IPU N I RAC A-a-9 GROUP COMPANY SolarMount Beam Connection Hardware SolarMount L-Foot Part No. 310065, 310066, 310067, 310068 • L-Foot material:One of the following extruded aluminum alloys:6005- . - '` T5,6105-T5,6061-T6 • Ultimate tensile:38ksi,Yield:35 ksi - '`'' = Finish:Clear or Dark Anodized {= • L-Foot weight:varies based on height—0.215 lbs(98g) Allowable and design loads are valid when components are Bea " assembled with SolarMount series beams according to authorized Bolt UNIRAC documents i L-Foot • For the beam to L-Foot connection: •Assemble with one ASTM F593%"-16 hex head screw and one ,�= errated ASTM F594%serrated flange nut Flange Nu ♦ _>• •Use anti-seize and tighten to 30 ft-lbs of torque f,. • Resistance factors and safety factors are determined according to part " 3' 1 section 9 of the 2005 Aluminum Design Manual and third-party test Y results from an IAS accredited laboratory A NOTE: Loads are given for the L-Foot to beam connection only; be -►X sure to check load limits for standoff,lag screw,or other attachment method 3.01 Applied Load Average Safety Design Resistance 3X SLOT FOR Direction Ultimate Allowable Load Factor, Load Factor, 3$HARDWARE lbs(N) lbs(N) FS lbs(N) 0 Sliding,Z± 1766(7856) 755(3356) 2.34 1141 (5077) 0.646 - 2 0 - Tension,Y+ 1859(8269) 707(3144) 2.63 1069(4755) 0.575 Dimensions specified in inches unless noted Compression,Y- 3258(14492) 1325(5893) 2.46 2004(8913) 0.615 Traverse,X± 486(2162) 213(949) 2.28 323(1436) 0.664 SOLARMOuNT Technical Datasheets U I RAC A HILTI GROUP COMPAN` SolarMount Beams Properties Units SolarMount SolarMount HD Beam Height in 2.5 3.0 Approximate Weight(per linear ft) plf 0.811 1.271 Total Cross Sectional Area in2 0.676 1.059 Section Modulus(X-Axis) in3 0.353 0.898 Section Modulus(Y-Axis) in3 0.113 0.221 Moment of Inertia(X-Axis) in4 0.464 1.450 Moment of Inertia(Y-Axis) in4 0.044 0.267 Radius of Gyration(X-Axis) in 0.289 1.170 Radius of Gyration(Y-Axis) in 0.254 0.502 SLOT FOR T-BOLT OR 1,728 1 SLOT FOR T-BOLT OR 4" HEX HEAD SCREW 1/4 HEX HEAD SCREW 2X SLOT FOR SLOT FOR BOTTOM CUP iti� 2.500 BOTTOM CUPiii-',7 3.000 lilT 1.316 I1, SLOT FOR 3/8"HEX BOLT ili / SLOT FOR 1385 3/8" HEX BOLT .387 1 .750 4.1 1.207 Y Y 1.875 A --I.-X -►X SolarMount Beam SolarMount HD Beam Dimensions specified in inches unless noted r SolarMount Unirac Code-Compliant Installation Manual :'U NI RAC [3.4] Installing SolarMount with grounding clips and lugs Clips and lugs are sold separately. Top mis mounting 1 , J clamps l.�.i �_ i Module ' I bolt Nib °"."N' 1 I 1 I Figure 26.Slide UGC-1 grounding *US s1 a UGC-1 _- clip into top mounting slot of rail. � Lr Torque modules in place on top of Conforms toaim clip.Nibs will penetrate rail anod- UL Standard 467 iaation and create grounding path ill' through rail(see Fig 3,reverse side). SolarMount®rail(any type) Figure 27.Insert a bolt in the WE EB Lug aluminum rail or through the clearance hole in the stainless steel flat washer.Place the stainless steel flat washer on the bolt,oriented so the dimples will contact the --,, aluminum raiL Place the lug portion F t on the bolt and stainless steel flat _ / d washer.Install stainless steel flat WEEBLug4404;410,101. washer,lock washer and nut. g Tighten the nut until the dimples are completely embedded into the rail -' and lug.The embedded dimples make Stainless Steel Flat agas-tight mechanical connection Washer(WEEB) and ensure good electrical connection between the aluminum rail and the ! Iug through the WEEB. , ount0 rail , ,._ (any hype) Figure 28.UGC-1 layout for even Figure 29.Single wire grounding and odd number of modules in row. with spliced rails. "X"denotes places to install UGC-1. KEY r aC k k PV module I SolarMount rail(any type) 4 Rail splice I * \ X Grounding lug Even Number of Modules in row — Copper wee I , ass < j +x—R aaa - l Odd Number of Modules in row Y Single grounding wire for entire array Page 25 Oa U N I RAC Unirac Code-Compliant Installation Manual SolarMount 10 year limited Product Warranty, 5 year limited Finish Warranty Unirac,Inc.,warrants to the original purchaser specified by AAMA 609&610-02—"Cleaning If within the specified Warranty periods the ("Purchaser")of product(s)that it manufactures and Maintenance for Architecturally Finished Product shall be reasonably proven to be ("Product")at the original installation site that Aluminum"(www.aamanet.org)are not followed defective,then Unirac shall repair or replace the the Product shall be free from defects in material by Purchaser.This Warranty does not cover defective Product,or any part thereof,in Unirac's and workmanship for a period of ten(10)years, damage to the Product that occurs during its sole discretion.Such repair or replacement shall except for the anodized finish,which finish shipment,storage,or installation. completely satisfy and discharge all of Unirac's shall be free from visible peeling,or cracking or liability with respect to this limited Warranty. This Warranty shall be VOID if installation of the chalking under normal atmospheric conditions Product is not performed in accordance with Under no circumstances shall Unirac be liable for a period of five(5)years,from the earlierUnirac's written installation instructions,or if the for special,indirect or consequential damages of I)the date the installation of the Product is Product has been modified,repaired,or reworked arising out of or related to use by Purchaser of completed,or 2)30 days after the purchase of the Product. in a manner not previously authorized by Unirac the Product by the original Purchaser("Finish IN WRITING,or if the Product is installed in Manufacturers of related items,such as PV Warranty"). an environment for which it was not designed. modules and flashings,may provide written The Finish Warranty does not apply to any foreign Unirac shall not be liable for consequential, warranties of their own.Unirac's limited Warranty residue deposited on the finish.All installations contingent or incidental damages arising out of covers only its Product,and not any related items. in corrosive atmospheric conditions are excluded. the use of the Product by Purchaser under any The Finish Warranty is VOID if the practices circumstances. ��� � NJ I RAC 1411 Broadway Boulevard NE ,age Albuquerque NM 87102-1545 USA 26 Stare Coat Steel ,_, ti - ,,.. _. („411., ... 1_21„ - , .. 1,11 xi , .:,4,4,.. ... ., . , A„,,,..j.,...ii! ,,_ ',_ ,--.-:-.., s table Roof01.t. 4-. ),(01-7: ., , , Hook .. alaim For Sidiails )( ) \-.- ( coAlun wwwo Steel re ,� acT � -� SCA9OS14 SCA9a :14•Ifi!,- $CA9Q r , , x. 4a 1 . I 3/8" --.- -r-f.m.,�,._. 5/16^ )' _ ,�.1-314„ 314" :' '314" tslot for 1-1/4" 5/16-18 , 116 18" RBolt 3118" 5" , sam am I 4-3l4" f 1-3/8" ' 1-3/4' j "' 1 n .fsJ y w ,__ � 318' 1-1/4" ± 7!8' Mounting Screw Hole �_ 3/4" 1-4•• `-for#14 g 5116 „y s,,,_�. Mounting Screws t.,;? El 1 ; 2-1/2" ? ...7,,,,, 1-9/16"Slot for 36 �r1s^ #14&5/16 Mounting Screws _.-._,_ 5830 Las Positas Road, Livermore, 94551 3948 Airway Drive, Rock Hill, South Carolina 29732 '"\i_ _ to A •\ r''"" nn Ili I Californian _ -_ Jnnn\ -„- -in-sr 1 _ _1 fl_ _ _1 _ s, . , , instction$ _ _ ___, \\ __ \ lk_. \_ ___ _ 1 1 / / J 1 — Locate Roof Rafters ___ ` L err". .fi "�", ` 3ja- -T,' f s, • , 6 3#f itea Y Pbn-are"‘,f +'-;t--3,---'`7'-'-'"� { '.r4 "�. ' :}', ' a4 0 rile Remove After marking, remove the tile directly over the rafter. 9 Fill & DriH& -.7- t---- Is , . ,. Set your roof hook in the desired location.Using a pencil, mark the center of the holes. Drill a pilot hole in each of the two holes using a 3/16" drill bit. Ensure that your sealant is room temperature and fill any hole as well as applying to the underside of the roof hook. 4 , f Fasten Hook to Roo . likii ... * Use the screws that came with the bracket and secure to the rafter. . ? � place Tile Secure Lower the tile down and secure back to roof. 1 r _, :_,,,,,,, _ _ _z,, _, , ..--.: _- - __, ,,-,:: - - - ff .2, k _ % �L.ar -1....r ---i'i; -)1_,3;:t ,;-:!.. ,_1-..:t. 1 , .„,,. ,,,,,, 1 q, t, 'tfitai- ,:kt:2'.:,. FF '' ,:, ;:‘: 90..!> 1 ; i V 7 * Enphase®Microinverters Enphase® M215 1 1 __ _ .. _ F„ , i a , ,,, .....,_,,,,,i1.,„,„,,,,,,,,,,,.....,„,,,,,,,,,,,..,„--„1,,.. 7„.. T } +f[trey £ ,._..z,-,—,, 4.1.--. ,,, , .,, .,,,,,,r* The Enphase M215 Microinverter with integrated ground delivers increased energy harvest and reduces design and installation complexity with its all-AC approach. With the advanced M215, the DC circuit is isolated and insulated from ground, so no Ground Electrode Conductor(GEC) is required for the microinverter.This further simplifies installation, enhances safety, and saves on labor and materials costs. The Enphase M215 integrates seamlessly with the Engage® Cable, the Envoy®Communications Gateway", and Enlighten®, Enphase's monitoring and analysis software. PRODUCTIVE SIMPLE RELIABLE - Maximizes energy production -No GEC needed for microinverter - More than 1 million hours of testing - Minimizes impact of shading, - No DC design or string calculation and millions of units shipped dust, and debris required - Industry-leading warranty, up to 25 - No single point of system failure - Easy installation with Engage years Cable Te] enphase® $A® ENERGY C US • Enphase®M215 Microinverter II DATA INPUT DATA(DC) M215-60-2LL-S22-IG/S23-IG/S24-IG Maximum input DC voltage 48 V Peak power tracking voltage 27 V-39 V Operating range 16 V-48 V Min/Max start voltage 22 V 648 V Max DC short circuit current 15 A Max input current 10 A OUTPUT DATA(AC) @208 VAC @240 VAC Peak output power ; 225 225 W Rated(continuous)output power 215 W 215 W Nominal output current 11 A(A rms at nominal duration) 0.9 A(A rms at nominal duration) Nominal voltage/range 208 V/183-229 V 240 V/211-264 V Nominal frequency/range 600.657-61 Hz 60.0/57-61 Hz Extended frequency range* 57-62.5 Hz 57-62.5 Hz Power factor >0.95 >0,95 Maximum units per 20 A branch circuit 25(three phase) 17(single phase) Maximum output fault current 850 mA rms for6 cycles 850 mA rms for 6 cycles _EFFICIENCY — CEC'weighted efficiency 240 VAC CEC weighted efficiency,208 VAC 96.5% Peak inverter efficiency 96.5% Static MPPT efficiency(weighted,reference EN50530) 99.4% Night time power consumptiora. 65 mW max . . : MECHANICAL DATA Ambient temperature range -40°C to+65°C Dimensions(WxHxD) 163 mm x 173 mm x 25 mm(without mounting bracket) Weight 1.6 kg(3.4 lbs). Cooling Natural convection-No fans Enclosure environmental rating Outdoor-NEMA 6 FEATURES Compatibility Compatible with 60-cell PV modules. Communication Power line Integrated ground The DC circuit meets the requirements for ungrounded PV arrays in NEC 690.35.Equipment ground is provided in the Engage Cable.No additional GEC or ground is required_Ground fault protection(GFP)is integrated into the microinverter. Monitoring Enlighten Manager and MyEnlighten monitoring options Compliance UL1741/1EEE1547, FCC Part 15 Class B,CAN/CSA-C22.2 NO.0-M91, 0.4-04,and 107.1-01 Frequency ranges can be extended beyond nominal if required by the utility To learn more about Enphase Microinverter technology, el enphase® visit enphase,com L J E N E R G Y 2014 Enphase Energy.All rights reserved.All trademarks or brands in this document are registered by their respective owner.