Loading...
14120051 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 10592 JOHNSON AVE CONTRACTOR:SOLARCITY PERMIT NO: 14120051 OWNER'S NAME: GREG SHEPHERD 3055 CLEARVIEW WAY DATE ISSUED: 12/10/2014 OWNER'S PHONE: 4085053410 SAN MATEO,CA 94402 PHONE NO:(650)638-1028 LICENSE ONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL ❑ COMMERCIAL ❑ 't INSTALL 14 PANEL PV SYSTEM ON SFDWL ROOFTOP 3.64 License Class c-�, ip p p c.# p p p (c) q KW j ! Contractor Date I hereby affirat I am licensed under the provisions of Chapter 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$8000 I have and will maintain Worker's Compensation hisurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:37528030 00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct.I agree to comply with all city and county ordinances and state laws relating WIT�IIN 180 DAYS OF PERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 DAYS FRAS ALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the granting of this permit. Additi lly, applicant understands and will comply Issued by: Date: Ja U LI-1 with all non-point source reg ons the Cupertino Municipal Code,Section 9 18. RE-ROOFS: Signature Date 102 /�/►� All roofs shall be inspected prior to any roofing material being installed.If a roof is installed without first obtaining an inspection,I agree to remove all new materials for inspection. ❑ OWNER-BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of Signature of Applicant: Date: the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER 1,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) 1,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(x)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use egmpmeut or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area i6r,Qu lity Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino uni ' al Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sections 25505 533, d 25534. Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Owner or authorized agent: Date: a M H I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address 1 certify that I have read this application and state that the above information is correct.1 agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino,against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9 18. Signature Date ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION go 10300 TORRE AVENUE•CUPERTINO,CA 95014-3255 CUPERTINO (408)777-3228•FAX(408)777-3333• building0cupertino.org PROJECT ADDRESS 10592 Johnson Ave. APN# . .�5 '­' OWNER NAME Anthony Chung PHGNE408-505-3410 E-MAIL STREET ADDRESS 10592 Johnson Ave. CITY, STATE,ZIP Cupertino,CA950 1 4 FAX CONTACT NAME Marjan Javanmard PHONE 650.477.6430 E-MAIL mjavanmard@solarcity.com STREET ADDRESS 391 Foster City Blvd CITY,STATE, ZIP Foster City, CA 94404 FAX ❑OWNER ❑ OWNER-BUILDER ❑ OWNER AGENT ❑ CONTRACTOR 0 CONTRACTOR AGENT ❑ ARCHITECT . ❑ENGINEER ❑ DEVELOPER TENANT CONTRACTOR NAMESOIarCity Corporation LICENSE NUMBER 888104 LICENSE TYPE C10 BUS.LIC#288 COMPANY NAME SolarCity Corporation E-MAIL mjavanmard@Solarcity.Com FAX 00 STREET ADDRESS 391 Foster City Blvd CITY,STATE,ZIP Foster City, CA 94404 PHONE 650.477.6430 ARCHITECTIENGINEER NAME LICENSE NUMBER BUS.LIC# COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE USE OF ❑ SFD or Duplex ❑ Multi-Family PROJECT IN WILDLAND PROJECT IN STRUCTURE: ❑ Commercial URBAN INTERFACE AREA ❑ Yes ❑ NO FLOOD ZONE ❑ Yes ❑ No ❑SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PANELS. NUMBER OF PANELS/UNITS: KILOWATTS(COMMERCIAL ONLY): TOTAL VALUATION: 00 0 00 DESCRIPTION OF WORK Installation-(14) rooftop flush mounted solar panel (3.64) kW 'RECEIVED BY: / ✓ ,, By my signature below,I certify to each of the following: I am the perry ner or authorized agent to act on the property owner's behalf. I have read this application and the information I have provided' correct. I h scription of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to building constructio . autl nz rep ese 'ves of Cu ertino to enter the above-identified property for inspection purposes. Signature of Applicant/Agent: Date: Q 1144 SUPPLE=NtFftFORMATION REQUIRED T;` o cE tisE oivt Y ;: W OVER-TW-COUNTER JD a EXPRESS U STANDARD 171 LARGE 0. p MAJOR PVApp_2011.doe revised 03/16/11 CITY OF CUPERTINO FEE ESTIMATOR- BUILDING DIVISION ADDRESS: 10592 johnson ave DATE: 12/10/2014 REVIEWED BY: Mendez APN: BP#: "VALUATION: 1$8,000 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY PENTAMATION USE: SFD or Duplex PERMIT TYPE: SOLAR-RE WORK install 14 panel pv system on sfdwl rooftop SCOPE RIM 1'hwlb. Flail Chc el'r Lie:. 111"T, ;',>trefitFee: } urnh. Permiti��r: 1 0 tlaer F'letmh Irr,g'rz ET Phifith. 111,vp. Tee- /("'c h s NOTE:This estimate does not include fees due to other Departments(La Planning,Public Works,Fire,Sanitary Sewer District,School District,etc). Thesefees are based on the prelimina information available and are only an estimate. Contact the De t or addn'l info, FEE ITEMS (Tee Resolution 11-053 E('. 7/1/13) FEE QTY/FEE I MISC ITEMS Plan Check Fee: $0.00 0 # Alternative Energy System Suppl. PC Fee: (F) Reg. ® OT 0:0 1 hrs $0.00 $236.00 IPHOTOVRES Photovoltaic System PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Feer Reg. ® OT0 0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 Work Without Permit? ® Yes (F) No $0.00 G Advanced Planning Fee: $0.00 Select a Non-Residential G f`�:ft'F'/ reit.';:litizim21;7t7<1Y7 I' i's. Building or Structure Strong Motion Fee: IBSEISMICR $1.04 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $1.00 $2.04 $236.00 TOTAL FEE: $238.04 Revised: 10/01/2014 ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID–INTERTIED VIA A FLASHING WILL BE PAINTED TO MATCH EXTERIORt-OE'P�E1`� r 110 �" AC ALTERNATING CURRENT UL–LISTED POWER–CONDITIONING INVERTER. GpM�°A ,`3l" ������N� iV1op -GUrER� BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. t �)4LuiY� D �® E3uddirg Department CONIC CONCRETE 3. A NATIONALLY–RECOGNIZED TESTING ¢_ rons MUST be kept at the i DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN r r ^ �i,lcat ma e any r EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. srs ` r=, a.,.� sp'+ on It Is u;�,ual to co,:,atru�� e or to dGai4te (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING job sl` � `r"� ��rations on s"'" �. l';;, Ofi r`�`a1 € c i tFNIEf.) rOR CODE WMPLIANCE EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION Cw�a^�&5 of °�`� "rn ti`� °ur u t��, r r� a f, ��L No. A SIGN WILL BE PROVIDED WARNING OF THE �;i,,,,it a,p I; FSB FIRE SET–BACK ttsCrafi;om, s r,1?1Cu i�-,s eviewed By HAZARDS PER ART. 690.17. Ian and P :!S�it;n GALV GALVANIZED ; �,is P GEC GROUNDING ELECTRODE CONDUCTOR an 5. EACH UNGROUNDED CONDUCTOR OF THE T GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY l^ is �` a;, Citi HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. w 1'•ui r � ., I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC T, - T 11i✓1„T, LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN ATF (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. OFFICE — — -- -- NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL–LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING POI POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT PV1 COVER SHEET 3R NEMA 3R, RAINTIGHT i PV2 SITE PLAN _ PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS PV5 THEE LICENSE GENERAL NOTES Cut heets Attalched IAGRAM CA # 888104 1. ALL WORK TO BE DONE TO THE 2013 C-10 CALIFORNIA BUILDING CODE AND THE 2013 . CALIFORNIA RESIDENTIAL CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY THE 2013 CALIFORNIA ELECTRIC CODE. MODULE GROUNDING METHOD: ZEP SOLAR AHJ: Cupertino REV BY DATE COMMENTS REV A NAME DATE COMMENTS x * « x UTILITY: Pacific Gas and Electric Company ,>! J[3-9504183 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: CONTAINED SHALL NOT BE USED FOR THE CHUNG, ANTHONY CHUNG RESIDENCE Jack Faulkner `:,;So�arCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: Am NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 10592 JOHNSON AVE 3.64 KW PV ARRAY j���a PART OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: CUPERTINO, CA 95014 3055 Clearview Way THE SALE AND USE OF THE RESPECTIVE (14) REC # REC260PEZ PAGE NAME: SHEET: REV: DATE San Mateo,CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. ABB# PVI-3.0–OUTD–S–US–Z–A (408) 505-3410 COVER SHEET PV 1 12/5/2014 (B66)-SOL-CITY(765-2489)www.solarcity.com PITCH: 18 ARRAY PITCH:18 11131 AZIMUTH:212 ARRAY AZIMUTH:212 MATERIAL:Comp Shingle STORY: 2 Stories PITCH: 18 ARRAY PITCH:18 MP2 AZIMUTH:212 ARRAY AZIMUTH:212 MATERIAL:Comp Shingle STORY: 1 Story v U,'ulldir,g Qe;parllnent (.:iC)E \a01VIla✓,A/"NCE v7 C p (E)DRIVEWAY N LEGEND Q (E) UTILITY METER & WARNING LABEL Front Of House INVERTER W/ INTEGRATED DC DISCO a lnv & WARNING LABELS _ _3' FSB M ° I-M V DC DISCONNECT & WARNING LABELS L -n O ° B AC DISCONNECT & WARNING LABELS LEM aoI - 31nv Im DC JUNCTION/COMBINER BOX & LABELS V) 3' FSB _ U- DISTRIBUTION PANEL & LABELS WI A O wI O O Lc LOAD CENTER & WARNING LABELS B O DEDICATED PV SYSTEM METER nT N Q STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR -- CONDUIT RUN ON INTERIOR GATE/FENCE Q HEAT PRODUCING VENTS ARE RED INTERIOR EQUIPMENT IS DASHED L_"J TOTAL ARRAY AREA (SF): 254 SITE PLAN TOTAL ROOF AREA (SF): 0 Scale: 3/32" = 1' IV TOTAL ARRAY AREA IS N Infinity 01' 10' 21' S PERCENT OF TOTAL ROOF AREA J B-9 5 0 418 3 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: CONTAINED SHALL NOT BE USED FOR THE CHUNG, ANTHONY CHUNG RESIDENCE Jack Faulkner SolarCity.BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: "` NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 10592 JOHNSON AVE 3.64 KW PV ARRAY PART IZ OTHERS OUTSIDE THE RECIPIENT'S MODULES: CUPERTINO, CA 95014 ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 geardew Way THE SALE AND USE OF THE RESPECTIVE (14) REC # REC260PEZ PAGE NAME: SHEET: REV: DATE San Mateo,CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T.(650)638-1026 F:(650)638-1029 PERMISSION OF SOLARCITY INC. ABB PVI-3.0—OUTD—S—US—Z—A (408) 505-3410 SITE PLAN PV 2 12/5/2014 (888)-SGL-CITY(765-2469)www.solarcity.com S1 S1 2' 12'-7" 4" '-10' 13'-3" (E) LBW (E) LBW A SIDE VIEW OF MP1 NTS SIDE VIEW OF MP2 NTS 6 MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES MP2 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 72" 24" LANDSCAPE 72" 24" PORTRAIT 48" 20" PORTRAIT 48" 20" RAFTER 2X8 @ 24"OC ROOF AZI 212 PITCH 18 STORIES: 2 ARRAY AZI 212 PITCH 18 RAFTER 2X10 @ 24"OC ROOF AZI 212 PITCH 18 STORIES: 1 ARRAY AZI 212 PITCH 18 C.J. 2X8 @16"OC Comp Shingle Comp Shingle PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER CUPERTINO & FENDER WASHERS LOCATE RAFTER, MARK HOLE ;,ti, ,� 8uildirg Department ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT HOLE. j ,E .�� ZEP ARRAY SKIRT (6) 1 `' ' SEAL PILOT HOLE WITH �� (4) (2) POLYURETHANE SEALANT. ZEP COMP MOUNT C _ _ REVIEOVED FOR CODE COMPLIANCE ZEP FLASHING C (3) (3) INSERT FLASHING. evievre3 By � %'' '�'� (E) COMP. SHINGLE (4) PLACE MOUNT. (1) (E) ROOF DECKING (2) INSTALL LAG BOLT WITH 5/16" DIA STAINLESS (5) S (5) EALING WASHER. STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES �'NSTALLVELING FOOT WITH WITH SEALING WASHER ( & WASHERS. (2-1/2" EMBED, MIN) (E) RAFTER #_5TAN� J B-9504183 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: �\\ CONTAINED SHALL NOT BE USED FOR THE CHUNG, ANTHONY CHUNG RESIDENCE Jack Faulkner �;;;So�arCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �a NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 10592 JOHNSON AVE 3.64 KW PV ARRAY PART IZ OTHERS OUTSIDE THE RECIPIENTS MODULES: C U P E R TI N 0 CA 9 5014 3055 Gearview Way ORGANIZATION, EXCEPT IN CONNECTION WITH � THE SALE AND USE OF THE RESPECTIVE (14) REC # REC260PEZ SHEET: REV: DATE: San Mateo,CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. ABB# PVI-3.0-OUTD-S-US-Z-A (408) 505-3410 STRUCTURAL VIEWS PV 3 12/5/2014 (888)—SOL—CITY(765-2489)www.solarcitycom UPLIFT CALCULATIONS 12.05.2014 PV System Structural 4oSolarCity. Version#41.5 Ic�,t� s Desian Software Pro ect-Inifonlnation tic Table Of;Contents Risk Category: 11 pV SystenT Type Sblarcity Simmount- Comp Roof Comp Roof Layers o(brnp.Roofina 1 Roof Slope 180 Wertoadna 20-0.c PVSystem Module Orientation Landscape and Portrait PV Module Area: 249`sf PV Module Width 39" PV Module Length: 66" Standoff Attachment Hardware Comp Mount Type C Reduced,Groued/Roof lave/Seow Loads'; Ground Snow Load Pg 0.0 Psf ASCE Table 7-1 Surrounding Roof Snow. 00 psf ASCE Eq 7:41 Roof Snow Over PV Modules 0.0Psf ASCE E :7.4-1 Wind'4esi' n Criteria Wind Design Code ASCE 7-10 W1gdDesigiT.MetiT_od; PartfalhrlFully.Endosed Method Basic Wind Speed V 110 mph Fig 26.5-IA Expl ore Category C_.. °zectloo 2..7 Roof Style, Gable Roof Fig.304-zWij-ale M,en Rpgf Helght. h iSR:. :Sedion.262 Effective Wind Area i Module A 17.8 sf IBC 15093.1 WPI WV y� `,...,y.w.�. #�.; ..fi. r� Icuiatron;�oefFideM {. Wind Pressure Exposure Kz 0.85 Table 30.3-1 Wind Directionality Factor Kd 0.8.5 Section 26.671 Im�`i3ane;e_Eaio�ii I NA;. - - VelocKy Pressure qh qh=0.00256(Kz)(Kzt)(Kd)(V"2) "1 �TI N 22.4O E)krPressure.0 efiide NP) _ GAP P) _. -0.88 i ra gwe , ensure dent ornmi 0 . . _ . >n`:a ccsfVa Pwildirg DePartmenil Desi n 116qnd Pressure P p= h C 1 (, 2014 Wind Pressure Down down 16.0 c- _. �� c'aC)L�E CC7MPLl�tNC Mail Allowable?standoff "acing Landscape n. � �r ., •_._. .1. }i3. . .: C� Standoff Confi uratlonLandsca _... Not-sta Bred ... fi..211 ..__._ , . PV Assembly Dead Load�. W PV 3 Psf N.4 Wind Uplifkat Standoff T nCtnal 196 itis. Uplift Capacity of Standoff T allow 500 Ills :ndoff Deman DCft 39.1% Max Allowable Standoff Spacing Portrait 48" 66" Rax Allowable Gar 0Vver Portiait: 20" NA. Standoff Configuration Portrait Not-Staggered MaR:StaWTi[ibtttary" T%ib 22g PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at5tandt ff T-actual -219 IliS Uplift Capadt�+of Standoff T-allow 500 lbs Standoff man DCR 43.8% J B-9504183 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: \\\ CONTAINED SHALL NOT BE USED FOR THE CHUNG, ANTHONY CHUNG RESIDENCE Jack Faulkner BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: .,���� :So�arC�ty NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 10592 JOHNSON AVE 3.64 KW PV ARRAY PART OTHERS OUTSIDE THE RECIPIENTS MODULES C U P E R TI N 0, C A 9 5014 3055 CleaNew Way ORGANIZIZAl10N, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (14) REC # REC260PEZ PAGE NAME MEET, REV: DATE: San Mateo,CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: L•(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. ABB PVI-3.0-OUTD-S-US-Z-A (408) 505-3410 UPLIFT CALCULATIONS PV 4 12/5/2014 (888)—SOL—CITY(765-2489)www.solarcitycom GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (E) GROUND ROD Panel Number:SC204OM200C Inv 1: DC Ungrounded INV 1 -(1)ABB# PVI-3.0-OUTD-S-US-Z-A LABEL: A -(14)REC # REC260PEZ CA # 888104 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:1006134052 FCI Inverter; Zigbee 3000W, 240V, 96% PV Module; 26OW, 234.3W PTC, MC4, 40mm, Black Frame, ZEP Enabled C-10 Overhead Service Entrance INV 2 Voc: 37,8 Vpmax: 30.7 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 200A CENTER-FED MAIN SERVICE PANEL SolarCity E 20OA/2P MAIN CIRCUIT BREAKER Inverter 1 IND 5 ABB 4 A I DC- Vstart= DEFAULT 200A/2P PVI-3.0—OUTD—S—US—Z—A DC- MP 2: 1x7 (E) LOADS _ EGc ————————————-----� zaov ———————————— -------- -- Ll L2 ' DC+ � N DG I 3 2 Vstart = DEFAULT 20A/2P ----------__-------___ _EGC/ DC+ DC+ r-------------------------- GEC ---T A i DC- DG MP 1: 1x7 I B I GND __ EGC--- ————————— tl)Conduit ------------ ---�---- -- — EGC-----------------� I I I Kit; 3/4' EMT N ' I I EGC/GEC — Z Z c9 --— GEC --� TO 120/240V ' SINGLE PHASE UTILITY SERVICE I �— Ouildir,g DmAertrnenw . ._. 1 2014 ca r i V�iEL l OR CODE COMPZtANCE reviewed By 1 Voc* = MAX VOC AT MIN TEMP oI (1)SQUARE D 4 HgM220 PV BACKFEED BREAKER /� A (I SolarCit #4 STRING JUNCTION BOX Breaker, A 2P, 2 Spaces /y 2x2 S1MGS UNFUSED,GROUNDED DC 5 1 AWG #10, THWN-2, Black (1)AWG#10, THWN-2, Black Voc* 288.18 VDC Isc 9.01 ADC (2)AWG#10, PV WIRE, Black Voc* =288.18 VDC Isc 9.01 ADC O141—(1)AWG #10, THWN-2, Red . (1)AWG#10, THWN-2, Red Vmp =214.9 VDC Imp=8.5 ADC O (1)AWG#10, Solid Bare Copper EGC Vmp =214.9 VDC Imp=8.5 ADC L^ (1)AWG #10, 1HWN-2, White NEUTRAL Vmp =240 VAC Imp=14.5 AAC (1 AWG#10, THWN-2,.Green_. EGC. . . . . . . . 70 AWG #8,,1HWN-2,.Green . , EGC/GEC, (1)Conduit,Kit;.3/4",EMT, . ., .. , , _. (1 AWG#10, THWN—P, Black Voc* =288.18 VDC Isc =9.01 ADC (2)AWG#10, PV WIRE, Black Voc* =288.18 VDC Isc =9.01 ADC ® (1)AWG 110, THWN-2, Red Vmp =214.9 VDC Imp=8.5 ADC O (1)AWG 110, Solid Bare Copper EGC Vmp =214.9 VDC Imp=8.5 ADC . . . . . . . �1)AWG#10, TIiWN-2. Green EGC .. .. . . .. . . . . . . . . .. .. .. .. . ... . . . . . . . . . . .. .. .. .... .. . . .. . . .. . .. .. .. . . . . . . ...... . . . . . . .. .... .. .. ... .. . . . .... .. . JB-9504183 O O PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN [ER �\\ CONTAINED SHALL NOT BE USED FOR THE CHUNG, ANTHONY CHUNG RESIDENCE Jack Faulkner I„�Olar.�l}" BENEFIT OF ANYONE EXCEPT SOLARCITY INC., TEM: W,," l•r® NOR SHALL IT BE DISCLOSED IN WHOLE OR INount Type C 10592 JOHNSON AVE 3.64 KW PV ARRAY PART IZ OTHERS OUTSIDE THE RECIPIENTS CUPERTINO CA 95014 3055 Clearview Way ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE C # REC260PEZ SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV: DATE San Mateo, F. 94402 PERMISSION OF SOLARCITY INC. 408 505-3410 PV 5 12/5/2014 8:(650) CITY(7 5 F89)w 638-102 VI-3.0—OUTD—S—US—Z—A ) THREE LINE DIAGRAM (8B8)—SOL—CITY Label Location: Label Location: Label Location: WARNING:PHOTOVOLTAIC POWER SOURCE WARNING Per Code: Code: PV SYSTEM DISCONNECT FOR CRC R331.2UTILITY OPERATION ELECTRIC SHOCK HAZARD CEC • THE DC CONDUCTORS OF THIS Label Location: PHOTOVOLTAIC SYSTEM ARE • BE USED WHEN INVERTERIS PHOTOVOLTAIC DC MAY BEOENDERGIZED DISCONNECTPer Code: UNGROUNDED CEC .•0 .14.C.2 Label Location: Per WARNING ..- ELECTRIC SHOCK HAZARD Label • • CEC 690.17 DO NOT TOUCH TERMINALS MAXIMUM POWER- TERMINALS ON BOTH LINE AND POINT CURRENT(Imp)_qPer Code: LOAD SIDES MAY BE FAROUIIIIIIII MAXIMUM POWER- VCEC 690.53 IN THE OPEN POSITION POINT VOLTAGE(Vmp) MAXIMUMTASYSTEM V VOLGE(Voc) SHORT-CIRCUIT CURRENT(Isc) A Label • • WARNING '' Per ..- INVERTER OUTPUT ) CONNECTION Label Location: DO NOT RELOCATE WARNING Per THIS OVERCURRENT DEVICE ••- CEC ELECTRICALSHOCK HAZARD DO NOT TOUCH TERMINALS '' TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION Label • - • DC VOLTAGE IS PHOTOVOLTAIC POINT OF '• ALWAYS PRESENT WHEN INTERCONNECTION PerCode: SOLAR MODULES ARE WARNING:ELECTRIC SHOCK 690.54; • 90.17 EXPOSED TO SUNLIGHT HAZARD.DO NOT TOUCH TERMINALS.TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION.FOR SERVICE Department Label Location: DE-ENERGIZE BOTH SOURCE WARNING Per AND MAIN BREAKER. 2014 PV POWER SOURCE Code: MAXIMUM AC ELECTRIC SHOCK HAZARD 690.5(C) OPERATING CURRENT A COMPLIANCE IF A GROUND FAULT IS INDICATED NORMALLY GROUNDED MAXIMUM AC ® V CONDUCTORS MAY BE OPERATING VOLTAGE UNGROUNDED AND ENERGIZED Label • • Label tion: PHOTOVOLTAIC AC )'• CAUTION Code:Per Disconnect PHOTOVOLTAIC SYSTEM 690.64.13.4 DISCONNECTPer• 690.14.C.2 •� � CIRCUIT IS BACKFEDCombiner B• . Distribution DC Disconnect (IC): Interior Run Cond - • . Label Location: Label Location: (INV): Inverter With Integrated DC Disconnect MAXIMUM AC _ q • • CAUTION • •-' Center OPERATING CURRENTPer Code: DUAL POWER SOURCE ••_ (M): Utility - MAXIMUM AC V 690.54 • Point of _ • nnection OPERATING VOLTAGE PHOTOVOLTAIC SYSTEM 1 1 1' • 1 1 1 1 1' 3055 Cleaview Way 1 1 1 •« 1• 1 1 1San Mateo,CA ,A •1 1' 1 1 T 1 �1 1' 1SC Label li 02 ••1 1 11 1 1 1 A l 7 1 1 1 SolarCity SleekMountT"" - Comp SolarCity SleekMountTM - Comp The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listed Installation Instructions is optimized to achieve superior strength and Zep CompatibleTM modules `z aesthetics while minimizing roof disruption and7, Drill Pilot Hole of Proper Diameter for labor.The elimination of visible rail ends and •Interlock and grounding devices in system UL Fastener Size Per NDS Section 1.1.3.2 listed to UL 2703 mounting clamps, combined with the addition / Seal pilot hole with roofing sealant of array trim and a lower profile all contribute •Interlock and Ground Zep ETL listed to UL 1703 _ to a more visually appealing system. SleekMount as"Grounding and Bonding System" Insert Comp Mount flashing under upper utilizes Zep Compatible TM modules with •Ground Zep UL and ETL listed to UL 467 as layer of shingle strengthened frames that attach directly to grounding device Place Comp Mount centered Zep Solar standoffs,effectively eliminating the need for rail and reducing the number of •Painted galvanized waterproof flashing upon flashing standoffs required. In addition, composition .Anodized components for corrosion resistance Install lag pursuant to NDS Section 11.1.3 shingles are not required to be cut for thisy __- with sealing washer. system, allowing for minimal roof disturbance. •Applicable for vent spanning functions Secure Leveling Foot to the Comp Mount using machine Screw Place module ® Components 5/16"Machine Screw ® 0 Leveling Foot 0 Lag Screw ® Comp Mount ® ® Comp Mount Flashing p O C-UPE j �3.111dirQ Dwarkratenf "C w. 0 2014 �C7� ,et:.� 1.; C;ij L)E COMPLIANCE nY® SolarCityo January 2013 ��% E1� V� LISTED �P� SOlarCityv January2013 Additional highlights: a+•-Solar inverters — RS-485 communication interface (for connection to laptop or data logger). — Integrated Arc Fault Detection and AU Interruption(-A Version). C LJx, ,k c h { Technical data and types Type code PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US PVI-4.2-OUTD-US ACC Mechanical specifications Nominal output power 3000W 360OW 3W0 380OW 420OW .................................................................... .........................................[................................ 1 Maximum output power wattage 3000 3300' i 3300' : 3600 : 4000' 40001 i 3300 42001 4200' : 4200 i 46001 4600{ �..., RatW W W W W W W W W W W ....... W i................................................................................ ...... ...i.... .. ....... .......7 ...,....0 ....... ...,.... 7 ...,....0 ....... ed grdCog208V , 240V277V , 208V , 240V27V28V240V27V28V240V , 277 V.... Input side(DO) Number of independent MPPT channels 2 2 2 2 .. .......... .. ........... Maximum usable power for each channel 2000W 3000W 3000W 3000W Absolute maximum voltage(Vmax) 600V Start-up voltage(Vstart)..... 200V(ad1.120 350V) ........... ... Full power MPPT voila e ran e 160-530V 120-530V 140-530V 140-530V rz9 .......9.......................................... .7 Vtrt V>= Operating MPPT voltage range. .. 0. x Vstart-580....(. 90V)..... .... ........ .. ..... ... ...... ..... ... e Maxlmum current(I'dcmax)for both MPPT in 20A 32A 32A 32A a .parallel...... a Maximum usable current per channel 10A 16A 116A �y Maxlmum short circuit current limit per 6A 12.5A 20.OA20.OA 20.OA _channel ................. ... ..................................... ......... ............................... ................ ......................................................... ............ ................ ' Number of wire landin terminals er channel ' ?pair 9.. ...............P.......... ....... .............. ................. .... I?.... .... ............ .. ................. Array wiring termination Terminal block,pressure clamp,AWG10-AWG4 Output side,(AC) g 10/ Split 10/ 10/ Spilt 1fd/ 1fd/ Spilt 1fd/ 1R1/ Split 10/ Grid connection type 2W ': 0/3W: 2W 2W : 0/3W 2W 2W 0/3W ) 2W 2W : 0/3W 2W .........................................................................................................................................................................................................................................................:.................................................................................................... Adjustable voltage range(Vmin-Vmax)(V) 183- 211- 244- 183- 211- 244- 183- 211- 244- 183- 211- 244- 228V__i__264V...1.._304V._.._228V € 264V 304V i 228V i 264V i 304V € 228V 264V i 304V ........................................... ...... .............................. '''" Grid fre uenc 60Hz 9.... Y. ................. .... . ..... ................. ............ Adjustable grid frequency,range 57-60.51-1z Maximum current(I�,m,) 14.5 14 5 12.0 17.2 16.0 i 160 16.0 16.0 16.0 20.0 20.0 20.0 ...........................:.:.............................................................. .................:. ....... ......._!1w�s....i..._Aarns....i..._:4arns......._Aaus....i....Ai....!��ws.......!�wns......._Aaus........Awes....[..._Ara,,s......._!aR,ns..... Power factor >0.995 ................................................................................................................................................................................................................................................................ Total harmonic distortion at rated ower <2% ? p y q' P........................................................................................ .............................. U� ��1V This family of single-phase string The high-speed MPPT offers real- Highlights: Grid wrong termination type Terminal block Pressure camp,AWG10-;k 4 inverters complements the typical time power tracking and improved — Single phase and split phase output N �e61� (t3(GbSA . ., � ,:_ .t+„_ t,,..r c K�swr t .F _ x .:y_ 6ulldirg Department Reverse plarity protection Yes number of rooftop solar panels energy harvesting. grid connection. ............p................... ......... ...........................................................................................................................F ..::_........................................ p p 9Y 9 Over-vofta9e..P..rotection.ty..R. ................................................._........................................................................;...Varistor,..2.for.each channel...............;.......i”�4 ri...........::.1............................... enabling home-owners to get the most The flat efficiency curve ensures high — Wide input range for increased PV array ground fault detection Pre start up Riso and Dynamic GFDI(re uires floatinglsa 1 f eh y efficient energy harvesting for the size efficiency at all output levels allowing stringing flexibility. 2014 Anti-islanding protection Meets UL 1741/IEEE1547 requirements of the property. a consistent and stable performance — The hi h speed and recise MPPT ---------------- .......................... ' 9 Over voltage protection type.-...._......-. Vanstor,2(L, Lz/L, G) ......... .... across the entire input voltage and algorithm offers real time power Maximum AC OCPD Rating 20A, 2oA',; 15A,, 25A„° 2oA 2oA;,, 2oA,, 2oA, ;20A1,3....MMEDI ONS CODE C.OMPA IANCUr This inverter offers a dual input output power range. tracking and improved energy Efficiency section that processes two strings The transformerless operation gives the harvesting. Maximum efficiency 96 9% 97% 97/0 et9��o�� P 9 P 9 9• CEC efficiency 96% Y _ /•�T�s7 i.• with independent Multiple Power Point highest efficiency of up to 97.0%. — Outdoor NEMA 4X rated enclosure Operating performance Tracking(MPPT). The wide input voltage range makes for unrestricted use under any Night time consumption <0.6W°„1 This is especially useful for rooftop the inverter suitable to low power environmental conditions. Communicationmption <8W installations with two different installations with reduced string size. — Integrated DC disconnect switch User-interface 16 characters 2 lines LCD display orientations from two sub-arrays This rugged outdoor inverter has been in compliance with international Remote monitoring(1xRS485 incl.) VSN700 Data Logger(opt.) oriented in different directions.(For designed to be a completely sealed Standards(-S Version). Environmental Ambient air operating temperature range..............i............................................. ...______-13°F to+...40°F with,derating above.122°F(50°L)............................................................._ example:East and West) unit able to withstand the harshest Ambient air storage temperature range 40°F to+176°F(40 C to+80 C) ... .. .... The dual input sections with environmental conditions. Relative humidity o-100%RH condensing Acoustic noise emission level <50 db(A)p 1 m independent MPPT enable a more ....................................................................................... ............................................................. p , No NoMaximum operating altitutde without derating ! 6560 ft(2000 m) optimal energy harvesting condition. t.Capability enabled at nominal AC voltage and with sufficient DC power available. Power and productivity for abetter world” PUMP 2 ABB Solar Inverters I Product flyer for PVI-3.0/3.6/3.8/4.2-TL-0UTD 35 vrn s 4,S ht ✓"dXb �: ct l r�'x u``''-. 5.,'NE*lc,:;d. M* rwef 'EFFIGIENCY =YEAR PRODUCT WARRANTY ` SOLAR PANELS ' YEAR'LINEAR POWER + OUTPUT WARRANTY 47 77x 1 ""REE° DUTY'FRSE s I i l 1 P 13a 4 i Rpm TEMPERATURE RATINGS R All measurements in inches v` DA rA(a)STC REC25SPEZ r. Nominal power-PMPP(Wp) 255 260 265 Watt Class Sorting-(Wp) t5 ±S •5 Nominal PowerVoltage-VMPP(V) 30.5 30.7 30.9 orf Nominal PowerCurrent-IMpp(A) 8.42 8.S0 8.58 Open Circuit Voltage-Vot(V) 37.6 37.8 38.1 Short Circuit Current-Ist(A) 8.95 9.01 9.08 . PanelEfficiency(%) 15.5 15.8 16.1 The electrical characteristics are within 10%ofthe indicated values of l V.and P.,s,at standard Test conditions(STC). Values at standard test conditions STC(airmass AM1.5,irradiance 1000cell temperature 25'C). At low irradiance of 200 W/m'(AM 1.5 and cell temperature 25°C)at least 97%of the STC panel efficiency will be achieved. �I Nominal Power-P.,(Wp) 193 197 202 �.� Nominal Power Voltage-VMpp(V) 28.5 29.0 29.4 NominalPower Current-I,(A) 6.77 6.81 6.90 Open Circuit Voltage-Voc(V) 35.3 35.7 36.0 Short Circuit Current-Isc(A) 7.21 7.24 7.30 Nominal operating cell temperature NOCT(800 W/m�AM 1.5,windspeed 1 m/s,ambient temperature 20'C). - III10 year product warranty. C @us 2S year knear power output warranty LISTED (max.degression in performance of 0.7%p.a.). UL 1703,Fire rating:Class C 1NO REC is a leading global provider of solar energy solutions. With more than 15 years of experience,we offer sustainable,high performing C f7E'Dar ' products,services and investments for the solar industry. Together with our partners,we create value by providing solutions that better ' CE°r1� meet the world's growing energy needs.REC is headquartered in Norway and listed on the Oslo Stock Exchange(ticker:RECSOL)..Ourl,600 employees worldwide generated revenues of USD 647 million in 2013. 1vwW.recgio4p.corti Nfaq j WDE Ct)PIAPLIANCk