Loading...
15070014CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 18661 PRING CT CONTRACTOR: WONG TONY AND PERMIT NO: 15070014 DIANA TRUSTEE OWNER'S NAME: WONG TONY AND DIANA TRUSTEE 12354 PRISCILLA LN DATE ISSUED: 07/022015 OWNER'S PHONE: 6509178188 LOS ALTOS, CA 84022 PHONE NO: ❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL E] COMMERCIAL TEAR OFF (E) T & G, INSTALL (1) CLASS A COMP ROOF License Class Lic. # SYSTEM (13 SQ'S) Contractor Date I hereby affirm that I an► licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the Sq. Ft Floor Area: Valuation: $6000 performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this APN Number: 37525038.00 Occupant} "fN pc: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITBIN 180 DAYS OF PERMIT ISSUANCE OR to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save 180 DAYS INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities, judgments, ! costs, and expenses which may accrue against said City in consequence of the Date: Z granting of this permit. Additionally, the applicant understands and will comply Y: with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. RE -ROOFS: Signature Date All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. :Z1211 - OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of Signature of Applicant: Date: r the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) I, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(a) should I store or handle hazardous I have and will maintain a Certificate of Consent to self -insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and I have and will maintain Worker's Compensation Insurance, as provided for by the Health & Safety Code, Sections 25505, 25533, and 25534. Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.: Owner or authorized agent: Date I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code, I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, ARCHITECT'S DECLARATION costs, and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section Licensed Professional 9.18. Signature Date Z r� CUPERTINO REROOF PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building(d1cupertino.org G'6 �_ nr I/ V PROJECT ADDRESS / ¢�f E&�PG APN # OWNERNAME �i. ` (J / /� PHON yL) _ E-MAIL STREETADDRES" � tea/ CITY. STATT cn S FAX CONTACT NAME0N W 0� PHO %WLR / — E-MAIL STREET ADDRESS0 S O D CITY, T E QIP, �, / 1_ Eyl A FAX ❑ OWNER OWNER -BUILDER ❑ OWNER AGENT ❑ CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME ^ - / LICENSE NUMBER LICENSE TYPE BUS. LIC. it COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS. LIC. # COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE USE OF SFD or Duplex ❑ Multi-Fatnily STRUCTURE: E]Commercial y ROOF AREA W' COU ✓ VALUATION: v 0 0 EXISTING ROOF TYPE: BUILT-UP ROOF ❑ ASPHALT SHINGLES ❑ WO D SHAKES ❑ WOOD SHINGLES El OTHER (SPECIFY) REMOVE /REPLACE ES ❑ NO IF NO, #LAYERS PLYWOOD /:" ❑ THICKNESS ❑ 5/8" PLYWD ❑ OSB TYPE ❑ CDX PITCH: 12 ROOF CLASS: A PROPOSED ROOF TYPE: ❑ BUILT-UP ROOF ❑ ASPHALT SHINGLES ❑ WOOD SHAKES ❑ WOOD SHINGLES ❑ OTHER ICC -ES REPORT 9 DESCRIPTION OF WORK:_ ROD , A l/�/ t TT U 0<177-10 � ILI l� Cl _ �r INc1-31 By my signature below, I certify to each of the following: I am the property owner or authorized aeent to act on the property owner's behalf. I have read this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to building construction. rize representatives of Cupertino to enter the above -id ntified roperty for inspection purposes. Signature of Applicant/Agent: Date: SUPPLEMENTA FORMATION RE D _ If building is associated With a Home Owners Association, provide letter Of approval from HOA. _ Provide Planning approval to verify if there any restrictions. Provide copy of Manufacturer's Installation Specifications, Provide signed copy of Cupertino's Tear -Off Policy. OFFICE USE ONLY kLAN CHECK TYPE ROUTING SLIP OVER-THE-COUNTER ❑ EXPRESS ❑ STANDARD ❑ BUILDING PLAN REVIEW ❑ PLANNING PLAN REVIEW ❑ FIRE DEPT ❑ OTHER: ReroofApp_2011. doe revised 03/16/11 CITY OF CUPERTINO @W,0, FEE ESTIMATOR — BUILDING DIVISION 1A, ADDRESS. 19661 PRING CT DATE: 07/02/2015 REVIEWED BY: MELISSA .Ifech Permit f ev>:>'lumh. APN: 375 25 038 BP#: /�/ 'VALUATION: 1$6,000 *PERMIT TYPE: Minor Building Permit PLAN CHECK TYPE: Re -roof PRIMARY SFD or Duplex USE: I PENTAMATION 1 SFDWLROOF I PERMIT TYPE: WORK TEAR OFF E T& G INSTALL N CLASS A COMP ROOF SYSTEM 13 SQ'S SCOPE Sippl. Insp Fee FEE ID ROOF AREA s.f. 1 REROOFFRES 1,300 NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School District, etc). These fees are based on the preliminary information available and are only an estimate. Contact the Dept for addh 7 info. FEE ITEMS (&e Resolution 11-053 Eff: T,1%13) ,ilech. Plan Check Phunb. Plan Check 1, lec. Plan Check .Ifech Permit f ev>:>'lumh. Permit Fo Elea Permit V te:r,Rech. Ins?.F-1 1_ Ll,liech Other• Plumb Insp. F-1 I c)thet• Elec. Insp. Ll Insp. Fee: Plumb. htsh. Fee: Glec. Insp. Fee: NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School District, etc). These fees are based on the preliminary information available and are only an estimate. Contact the Dept for addh 7 info. FEE ITEMS (&e Resolution 11-053 Eff: T,1%13) FEE QTY/FEE MISC ITEMS Plan Check Fee: .`uppl..PC Fee 1umb./A1ech./E1ec Permit Fee: $221.00 Sippl. Insp Fee Plumh.liVech.; Elec Plumb.: Alech.iElec Pernail Fee: Construction .Tax: -ldministrative Fee: Work Without Permit? 0 Yes (F) No $0.00 Advanced Planning Fees: I r ivel Uocumenlati(m Fees: Strong Motion Fee: IBSEISMICR $0.78 Select an Administrative Item Bldp- Stds Commission Fee: IBCBSC $1.00 SUBTOTALS: $222.781$0.00 TOTAL FEE: I$222.78 Revised: 07/01/2015 X �SS.IDJ.r REROOF TEAR -OFF POLICY COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISION ALBERT SALVADOR, P.E., C.B.O., BUILDING OFFICIAL 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • buildingan.cupertino.org PROJECT ADDRESS i A6 c APN # 1 ZS I v OWNER NAMEO 1 t , „ , //� SSC, PHO _ E-MAIL STREET ADDRES .� �--- J L6A L CITY, °T "" / U L7o ��j FAX CONTRACTOR NAME 0 I� V � JV_ LICENSE NUMBER LICENSE TYPE BUS. LIC. k COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE I UNDERSTAND AND AGREE TO THE FOLLOWING: 1. The re -roof project shall comply with all applicable provisions of the 2013 California Codes. 2. An inspection request can be scheduled up to one business day before the requested inspection date. Please schedule inspections online or call (408) 777-3228 from 7:30-3:30pm (Mon-Thurs) or 7:30- 2:30pm (Friday) to schedule inspection. For Tear -Off and Nailing Inspections, you must also call on the day of the inspection only after that phase of the work is completed. The building inspector will be available within one hour. The hours for this service are: 7:30-10:30am and 12:30-3:30 (Mon-Thurs) and 7:30-10:30am and 12:30-2:30 (Friday). Final Inspections will be given a two hour window. 3. Tear -Off Inspection is required. Any and all dry -rotted wood shall be replaced prior to this inspection. Unless new plywood roof sheathing is proposed throughout, all the nails/fasteners shall be either completely knocked -down or removed prior to this inspection. 4. If plywood is installed, a plywood Nailing Inspection is required. 5. Roofing shall not be applied without first obtaining all prior inspection and written approvals from the building inspector. Any roofing which is applied without first obtaining an approved inspection will require the removal of all new material down to the sheathing so a proper inspection can be performed. 6. A Final Inspection and approval shall be obtained from the building inspector when the re -roofing is completed. To receive a final sign -off, the following items will be verified: a. Flat roofs shall have a minimum of I/4" per foot of slope and demonstrate there is no ponding. b. Listings from approved testing agencies for all pre -manufactured products used shall be available on-site to review at the time of the inspection. c. Proper spark arrestor installation, vents painted, gutter/downspouts installed, debris removed. 7. NOTE: If you call for a tear -off or plywood nailing inspection and the work is not complete, you will be charged a re -inspection fee. The re -inspection fee shall be paid before another inspection can be scheduled. By my signing below, I certify each of the following is true: I am the property owner or authorized agent to act on the property owner's behalf. I understand and agree to comply with the re -roof policy stated above. I also understand that smoke detectors and carbon monoxide detectors are required to be installed in accordance with Sections R314 and R315 of the 2013 California Residential Code. Signature of Applicant/Agent: Date: ReroofPolicy_2014.doc revised 01115114 CUPERTINO OWNER -BUILDER DISCLOSURE FORM COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building(alcupertino.org - Dear Property Owner(s): An application for a building permit has been submitted in your name listing yourself as the builder of the property improvements specified at: SITE ADDRESS TNC CT APN� —2 S O BPI�-69-00 OWNER NAME v` w 6lv OWNER 2ER ADDRESScs o s z d, OW) -Tti VE DESCRIPTION OF WORK: ,, — — C ( J =tw We are providing you with an Owner -Builder Acknowledgment and Information Verification Form to make you aware of your responsibilities and possible risk you may incur by having this permit issued in your name as the Owner -Builder. We will not issue a building permit until you have read, initialed your understanding of each provision, signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice unless you, the property owner, obtain the prior approval of the permitting authority. OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION (DIRECTIONS: Please read and initial each statement below to signify you understand or verify this information.) �1. 1 understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner - Builder" building permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as an Owner -Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my insurance coverage for injuries to workers on my property. �2. 1 understand building permits are not required to be signed by property owners unless they are responsible for the construction and are not hiring a licensed Contractor to assume this responsibility. �3. I understand as an "Owner -Builder" I am the responsible party of record on the permit. I understand that I may protect myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead of my own. —Z111)-4. 1 understand Contractors are required by law to be licensed and bonded in California and to list their license numbers on permits and contracts. �. 1 understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employer" under state and federal law. 6. 1 understand if I am considered an "employer" under state and federal law, I must register with the state and federal government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment compensation for each "employee." I also understand my failure to abide by these laws may subject me to serious financial risk. I understand under California Contractors' State License Law, an Owner -Builder who builds single-family re` sidential structures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed under contract with a licensed general building Contractor. 71�0- I understand as an Owner -Builder if I sell the property for which this permit is issued, I may be held liable for any financial or personal injuries sustained by any subsequent owner(s) that result from any latent construction defects in the workmanship or materials. OwnerBuilderForm 2010.doc revised 04/14/10 v� 9. 1 understand I may obtain more information regarding my obligations as an "employer" from the Internal evenue Service, the United States Small Business Administration, the California Department of Benefit Payments, and the California Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1-800-321-CSLB (2752) or www.cslb.ca.gov for more information about licensed contractors. _t/ 10. 1 am aware of and consent to an Owner -Builder building permit applied for in my name, and understand that am the party legally and financially responsible for proposed construction activity at the site address listed above. 11. 1 agree that, as the party legally and financially responsible for this proposed construction activity, I will abide y all applicable laws and requirements that govern Owner -Builders as well as employers. TVJ 12. 1 agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information l have provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with someone who does not have a license, the Contractors' State License Board may be unable to assist you with any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court. It is also important for you -to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working on your property, you may be held liable for damages. If you obtain a permit as Owner -Builder and wish to hire Contractors, you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers' compensation insurance coverage. CONSTRUCTION LENDING AGENCY (DIRECTIONS: Please complete the following construction lending agency information.) hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097 Civ.) Lender Name:AJIA Lender Address: Before a building permit can be issued, this form must be completed and signed by the property owner and returned to the agency responsible for issuing the permit. Note: A copy of the property owner's driver's license, form notarization, or other verification acceptable to the city may be required to be presented when the permit is issued to verify the property owner's signature. Property Owner's Signature: _ /. Date: / f Z DU --------------------------------------------------------------------------------------------------------------------------------------------- (NOTE: The following Authorization Form is required to be completed by the property owner only when designating an agent of the property owner to apply for a construction permit for the Owner -Builder). AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize the following person(s) to act as my agent(s) to apply for, sign, and file the documents necessary to obtain an Owner -Builder Permit for my project. Scope of Construction Project (or Description of Work): Project Location or Address: Name of Authorized Agent: Address of Authorized Agent: 1CaHN[•7 I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above information and certify its accuracy. Note: A copy of the property owner's driver's license, form notarization, or other verification acceptable to the city may be required to be presented when the permit is issued to verify the property owner's signature. Property Owner's Signature: Date: OwnerBuilderForm 2010.doc revised 04/14/10 CUPERTINO Owner Name WATER -CONSERVING PLUMBING FIXTURES OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISION 10300 TORRE AVENUE - CUPERTINO, CA 95014-3255 (408) 777-3228 - FAX (408) 777-3333 - building(a)cugertino.org FILE Address C1 �O 1 ��N!�? GT C_&tff&T N0 PERMIT CANNOT BE FINALED AND COTNIPLETED UNTIL TRIS CERTIFICATE HAS BEEN SI N,D .AND RETURNED TOTHE BUILDING DIVISION Please refer to the attached California Civil Code Sections 1101.1-1101.8 which are part of this Certification form. 1. Is your real property a registered historical site? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form. Owner' Signature: Date: -7114-11-5 VNo' Go to Question 2. 2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its plumbing, installation of water -conserving plumbing fixtures is not technically feasible? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. ❑ The licensed plumber's certification has been provided to the Building Division. Sign below and skip the rest of the form. Owner' Signature:Date: No Go to Question 3. 3. Is water service permanently disconnected for your building? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form. Owner' Signature: Date: �''f / o Go to Question 4. 6 4. Is your real property built and available for use or occupancy on or before January 1, 1994? ❑ No My real property is built and available for use or occupancy after January 1, 1994. Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the fonn. Owner' Signature: Date: -7 es My real property i built and available for use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101.8 apply. Refer to the attached. /Ony property is a single-family residential real property. See Civil Code Section 1101.4. and after January 1, 2014, building alterations or improvements shall require all non-compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non-compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements). ❑ My property is a multifamily residential real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water - conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). ❑ My property is a commercial real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. SB407 201 S.doc revised 02/04/15 i On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). UWe, the owner(s) of this property, certify under penalty of perjury that non-compliant plumbing fixtures will be replaced prior to date specified above with water -conserving plumbing fixtures in accordance with Civil Code Sections 1101.1 through 1101.8, the current California Plumbing Code and California Green Building Standards Code, and manufacturer's installation requirements, and that the water -conserving plumbing fixUzg comply with the requirements as indicated in the table below. Owner's (or Owner Agent's) Signature: Date f 14—Xj r -- Upon completing and signing this Certi$cate, please return it to the Building Division in order to final your pen -nit. 1. If the existing plumbing fixture water usage/flow rate is equal to or lower than the figure shown, it is not required to be upgraded. SB407 2015. doe revised 02/04/15 Non -Compliant Water -Conserving Plumbing Fixture Plumbing Fixturel (Fixture Complying with Current Code Applicable to New Construction) Maximum Water Usage/Flow Rate Fixture Type Water Usage 2013 CPC Ch. 4 2013 CPC Ch. 4 2013 CPC Ch. 4 /Flow Rate 2013 CALGreen Div. 4.3 2013 CALGreen Div. 4.3 2013 CALGreen Div. 5.3 Single -Family Multi -Family Commercial Residential Residential Water Closets Exceed 1.6 Single flush toilets: 1.28 gallons/flush (Toilets) Gallons/flush Dual flush toilets: 1.28 gallons/flush effective flush volume (the composite, average flush volume of two reduced flushes and one full flush Urinals Exceed 1.0 0.5 gallons/flush Gallons/flush Showerheads Exceed 2.5 2.0 gallons per minute @ 80 psi. Also certified to the performance criteria of gallons per minute U.S. EPA WaterSense Specification for Showerheads (A hand-held shower is considered a showerhead.) For multiple showerheads serving one shower, the combined flow rate of all showerheads and/or other shower outlets controlled by a single valve shall not exceed 2.0 gallons per minute @ 80 psi, or the shower shall be designed to allow only one shower outlet to be in operation at a time. Faucets – Exceed 2.2 gallons Maximum 1.5 gallons per Within units: 0.5 gallons per minute @ 60 Lavatory per minute minute @ 60 psi; minimum Maximum 1.5 gallons psi Faucets 0.8 gallons per minute @ per minute @ 60 psi; 20 psi minimum 0.8 gallons per minute @ 20 psi In common and public use areas: 0.5 gallons per minute @ 60 psi 1.8 gallons per minute 60 psi Faucets – Exceed 2.2 gallons 1.8 gallons per minute @ 1.8 gallons per minute 1.8 gallons per minute @ 60 Kitchen per minute 60 psi @ 60 psi psi Faucets May temporarily increase May temporarily up to 2.2 gallons per increase up to 2.2 minute @ 60 psi, and must gallons per minute @ default to maximum 60 psi, and must 1.8 gallons per minute @ default to maximum 60 psi 1.8 gallons per minute Where faucets meeting @ 60 psi the above are unavailable, Where faucets meeting aerators or other means the above are may be used to achieve unavailable, aerators or reduction. other means may be used to achieve reduction. 1. If the existing plumbing fixture water usage/flow rate is equal to or lower than the figure shown, it is not required to be upgraded. SB407 2015. doe revised 02/04/15 f CALIFORNIA CIVIL CODE SECTIONS 1101.1-1101.8 Civil Code Division 2. Property Part 4. Acquisition of Property Title 4. Transfer Chapter 2. Transfer of Real Property Article 1.4. Installation of Water Use Efficiency Improvements ........ 1101.1 — 1101.8 1101.1. The Legislature finds and declares all of the following: (a) Adequate water supply reliability for all uses is essential to the future economic and environmental health of California. (b) Environmentally sound strategies to meet fixture water supply and wastewater treatment needs are key to - protecting and restoring aquatic resources in.California. , _ (c)There isapressing need to address water supply-reliabilityissues raised by growing urban areas. -.(.d)-Economi-c analysisbyurbanwafer agencies has identifed urban water conservation as a cost-effective approach to -addressing water supply needs. (e) There are many water conservation practices that produce significant energy and other resource savings that should be encouraged as a matter of state policy. (f) Since the 1991 signing of the "Memorandum of Understanding Regarding Urban Water Conservation in California," many urban water and wastewater treatment agencies have gained valuable experience that can be applied to produce significant statewide savings of water, energy, and associated infrastructure costs. This experience indicates a need to regularly revise and update water conservation methodologies and practices. (g) To address these concerns, it is the intent of the Legislature to require that residential and commercial real property built and available for use or occupancy on or before January 1, 1994, be equipped with water -conserving plumbing fixtures. (h) It is further the intent of the Legislature that retail water suppliers are encouraged to provide incentives, financing mechanisms, and funding to assist property owners with these retrofit obligations. 1101.2. Except as provided in Section 1101.7, this article shall apply to residential and commercial real property built and available for use on or before January 1, 1994. 1101.3. For the purposes of this article: (a) "Commercial real property" means any real property that is improved with, or consisting of, a building that is intended for commercial use, including hotels and motels, that is not a single-family residential real property or a multifamily residential real property. (b) "Multifamily residential real property" means any real property that is improved with, or consisting of, a building containing more than one unit that is intended for human habitation, or any mixed residential -commercial buildings or portions thereof that are intended for human habitation. Multifamily residential real property includes residential hotels but does not include hotels and motels that are not residential hotels. (c) "Noncompliant plumbing fixture" means any of the following: (1) Any toilet manufactured to use more than 1.6 gallons of water per flush. (2) Any urinal manufactured to use more than one gallon of water per flush. (3) Any showerhead manufactured to have a flow capacity of more than 2.5 gallons of water per minute. (4) Any interior faucet that emits more than 2.2 gallons of water per minute. (d) "Single-family residential real property" means any real property that is improved with, or consisting of, a building containing not more than one unit that is intended for human habitation. (e) "Water -conserving plumbing fixture" means any fixture that is in compliance with current building standards applicable to a newly constructed real property of the same type. (fl "Sale or transfer" means the sale or transfer of an entire real property estate or the fee int eresi in that real property estate and does not include the sale or transfer of a partial interest, including a leasehold. 1101.4. (a) On and after January 1, 2014, for all building alterations or improvements to single-family residential real property, as a condition for issuance of a certificate of final completion and occupancy or final permit approval by the local building department, the permit applicant shall replace all noncompliant plumbing fixtures with water - conserving plumbing fixtures. (b) On or before January 1, 2017, noncompliant plumbing fixtures in any single-family residential real property shall be replaced by the property owner with water -conserving plumbing fixtures. (c) On and after January 1, 2017, a seller or transferor of single-family residential real property shall disclose in writing to the prospective purchaser or transferee the requirements of subdivision (b) and whether the real property includes any noncompliant plumbing fixtures. 1101.5. (a) On or before January 1, 2019, all noncompliant plumbing fixtures in any multifamily. residential real property and in any commercial real property shall be replaced with water -conserving plumbing fixtures. (b) An owner or the owner's agent may enter the owner's property for the purpose of installing, repairing, testing, and maintaining water -conserving plumbing fixtures required by this section, consistent with notice requirements of Section 1954. (c) On and after January 1, 2019; the water -conserving plumbing fixtures required by this section shall.be operating at the manufacturer's rated water consumption at the time that the tenant takes possession. A tenant shall be responsible for notifying the owner or owner's agent if the tenant becomes aware that a water -conserving plumbing- fixture within his or her unit is not operating at the manufacturer's rated water consumption. The owner or owner's agent shall correct an inoperability in a water -conserving plumbing fixture upon notice by the tenant. or if detected by the owner or the owner's agent. (d) (1) On and after January 1, 2014, all noncompliant plumbing fixtures in any multifamily residential real property and any commercial real property shall be replaced with water -conserving plumbing fixtures in the following circumstances: (A) For building additions in which the sum of concurrent building permits by the same permit applicant would increase the floor area of the space in a building by more than 10 percent, the building permit applicant shall replace all noncompliant plumbing fixtures in the building. (B) For building alterations or improvements in which the total construction cost estimated in the building permit is greater than one hundred fifty thousand dollars ($150,000), the building permit applicant shall replace all noncompliant plumbing fixtures that service the specific area of the improvement. (C) Notwithstanding subparagraph (A) or (B), for any alterations or improvements to a room in a building that require a building permit and that room contains any noncompliant plumbing fixtures, the building permit applicant shall replace all noncompliant plumbing fixtures in that room. (2) Replacement of all noncompliant plumbing fixtures with water -conserving plumbing fixtures, as described in paragraph (1), shall be a condition for issuance of a certificate of final completion and occupancy or final permit approval by the local building department. (e) On and after January 1, 2019, a seller or transferor of multifamily residential real property or of commercial real property shall disclose to the prospective purchaser or transferee, in writing, the requirements of subdivision (a) and whether the property includes any noncompliant plumbing fixtures. This disclosure may be included in other transactional documents. 1101.6. The duty of an owner or building permit applicant to comply with the requirements of this article shall be postponed for one year from the date of issuance of a demolition permit for the building. If the building is demolished within the one-year postponement, the requirements of this article shall not apply. If the building is not demolished after the expiration of one year, the provisions of this article shall apply, subject to appeal to the local building department, even though the demolition permit is still in effect or a new demolition permit has been issued. 1101.7. This article shall not apply to any of the following: (a) Registered historical sites. (b) Real property for which a licensed plumber certifies that, due to the age or configuration of the property or its plumbing, installation of water -conserving plumbing fixtures is not technically feasible. (c) A building for which water service is permanently disconnected. 1101.8. A city, county, or city and county, or a retail water supplier may do either of the following: (a) Enact local ordinances or establish policies that promote compliance with this article. (b) Enact local ordinances or establish policies that will result in a greater amount of water savings than those provided for in this article. In Address / 8 SMOKE / CARBON MONOXIDE ALARMS OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building(d,cupertino.org 7Ne� C 7 # o PURPOSE This affidavit is a self -certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R314, 2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single-family and multi -family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds w $1000.00, CRC Section 8314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations: AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of the bedroom(s) X X On every level of a dwelling unit including basements X X Within each sleeping room X Carbon Monoxide alarms are not required in dwellings which do not contain fuel -burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. Power Supply: In dwelling units with no commercial power supply, alarm(s) may be solely battery operated. In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl space. Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2. An electrical permit is required for alarms which must be connected to the building wiring. As owner of the above -referenced property, I hereby certify that the alarm(s) referenced above has/have been installed in accordance with the manufacturer's instructions and in compliance with the California Building and California Residential Codes. The alarms have been tested and are operational, as of the date signed below. 1 have read and agree to comply with the terms and conditions of this statement Owner (or Owner Agent's) Name: Vl Si nature ............... .. ....... ................................................................ Date:.......... . . Contractor Name: Sinature .......... ........................................................ .Lic.#...................................... Date:................... Smoke and CO form.doc revised 03/18/14