15070009G
CITY OF CUPERTINO BUILDING PERMIT
BUILDING ADDRESS: 850 LILY AVE
CONTRACTOR: CALIFORNIA DELTA
PERMIT NO: 15070009
MECHANICAL INC
OWNER'S NAME: HENRY WU
6056 E BASELINE RD STE 155
DATE ISSUED: 07/01/2015
OWNER'S PHONE: 4084648992
MESA, AZ 85206
PHONE NO: (866) 692-5273
❑ LICENSED CONTRACTOR'S DECLARATION
JOB DESCRIPTION: RESIDENTIAL COMMERCIAL
" y
Cass 2 0 Lic. #
REMOVE AND REPLACE A/C.
License
Contractor Date
I here rrm at I am licensed under the provisions of Chapter 9
(commencing with Section 7000) of Division 3 of the Business & Professions
Code and that my license is in full force and effect.
I hereby affirm under penalty of perjury one of the following two declarations:
I have and will maintain a certificate of consent to self-insure for Worker's
pensation, as provided for by Section 3700 of the Labor Code, for the
Sq. Ft Floor Area:
Valuation: `�66>O
rmance of the work for which this permit is issued.
?ave
and will maintain Worker's Compensation Insurance, as provided for by
Section 3700 of the Labor Code, for the performance of the work for which this
APN Number: 35903040.00
OccupancN Ty
permit is issued.
APPLICANT CERTIFICATION
I certify that I have read this application and state that the above information is
PERMIT EXPIRES IF WORK IS NOT STARTED
correct. I agree to comply with all city and county ordinances and state laws relating
WITHIN 180 DAYS OF PERMIT ISSUANCE OR
to building construction, and hereby authorize representatives of this city to enter
upon the above mentioned property for inspection purposes. (We) agree to save
180 DAYS FROM LAST CALLED INSPECTION.
indemnify and keep harmless the City of Cupertino against liabilities, judgments,
costs, and expenses which may accrue against said City in consequence of the
, l
���/�/Gf� 7-1 l
Issued by: Date:
granting of this permit. Additionally, the applicant understands and will comply
with all non-point source re ons per the Cupertino Municipal Code, Section
9.18.
�—
RE-ROOFS:
Signatur Date
All roofs shall be inspected prior to any roofing material being installed. If a roof is
installed without first obtaining an inspection, I agree to remove all new materials for
inspection.
❑ OWNER-BUILDER DECLARATION
Signature of Applicant: Date:
I hereby affirm that I am exempt from the Contractor's License Law for one of
the following two reasons:
ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER
1, as owner of the property, or my employees with wages as their sole compensation,
will do the work, and the structure is not intended or offered for sale (Sec.7044,
Business & Professions Code)
I, as owner of the property, am exclusively contracting with licensed contractors to
HAZARDOUS MATERIALS DISCLOSURE
construct the project (Sec.7044, Business & Professions Code).
I have read the hazardous materials requirements under Chapter 6.95 of the
California Health & Safety Code, Sections 25505, 25533, and 25534. 1 will
I hereby affirm under penalty of perjury one of the following three
maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the
declarations:
Health & Safety Code, Section 25532(x) should I store or handle hazardous
I have and will maintain a Certificate of Consent to self-insure for Worker's
material. Additionally, should I use equipment or devices which emit hazardous
Compensation, as provided for by Section 3700 of the Labor Code, for the
air contaminants as defined by the Bay Area Air Quality Management District 1
performance of the work for which this permit is issued.
will maintain compliance with the Cupertino al Code, Chapter 9.12 and
I have and will maintain Worker's Compensation Insurance, as provided for by
the Health & Safety Code, Sections f 33, and 25534.
Section 3700 of the Labor Code, for the performance of the work for which this
Owner or authorized a Date:
permit is issued.
I certify that in the performance of the work for which this permit is issued, I shall
not employ any person in any manner so as to become subject to the Worker's
Compensation laws of California. If, after making this certificate of exemption, I
CONSTRUCTION LENDING AGENCY
become subject to the Worker's Compensation provisions of the Labor Code, I must
I hereby affirm that there is a construction lending agency for the performance of
forthwith comply with such provisions or this permit shall be deemed revoked.
work's for which this permit is issued (Sec. 3097, Civ C.)
Lender's Name
APPLICANT CERTIFICATION
Lender's Address
I certify that I have read this application and state that the above information is
correct. I agree to comply with all city and county ordinances and state laws relating
to building construction, and hereby authorize representatives of this city to enter
upon the above mentioned property for inspection purposes. (We) agree to save
indemnify and keep harmless the City of Cupertino against liabilities, judgments,
ARCHITECT'S DECLARATION
costs, and expenses which may accrue against said City in consequence of the
I understand my plans shall be used as public records.
granting of this permit. Additionally, the applicant understands and will comply
with all non-point source regulations per the Cupertino Municipal Code, Section
Licensed Professional
9.18.
Signature Date
GENERAL PERMIT APPLICATION
COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION
10300 TORRE AVENUE • CUPERTINO, CA 95014-3255
(408) 777-3228 • FAX (408) 777-3333 • buildina(a.cupertino.org 1 �,�) ?d MISC
0�
❑ PLUMBING MECHANICAL ❑ ELECTRICAL ❑ MISCELLANEOUS
PROJECT ADDRESS/ OAeil'y�W
A�
/�
APN tt
v
ONER NAME
rNv
�4`-
PHONE
�`08�
Y Z
E-MAIL
STREET ADDRESS
CITY, STATE,C
FAX
T
,
CONTACT NAME
PHO.
E-MAIL
y vU
-
STREET ADDRESS
CITY, STATE, ZIP
FAX
!n r L�
❑ OWNER ❑ OWNER -BUILDER
❑ OWNERAGENT I CONTRACTOR ?I COT`TRACTORAGENT ❑ ARCHITECT ❑ ENGA'EER ❑ DEVELOPER ❑ TENANT
CONTRACTOR NAMEAJ��/
LICENSE
LICENSE T E
BUS. LIC
COMPANY NAME
E-MAIL
FAX
C /
STRE T ADDRESS
CITY, STATE, ZIPNE
�-
11>Q
.611>
ARCHITECT/ENGINEER NAME
LICENSE NUMBER
BUS. LIC n
COMPANY NAME
E-MAIL
FAX
STREET ADDRESS
CITY, STATE, ZIP
PHONE
USE OF TPSFD or DUPLEX
❑ MULTI -FAMILY
PROJECT IN WIL.DL.AND ❑ YES
PROJECT IN ❑ YES
IS THE BLDG AN ❑ YES
BUILDING: ❑ COMMERCIAL
URBAN IN=ACE AREA NO
FLOOD ZONE 2\10
EICHLER HOME? NO
DESCRIPTION OF WORK
T
TOTAL VALUATION:
RECEIVED BI " ='
By my signature below, I c ify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. I have read this
application and the information I have provided is correct. Jhave read the Description of Wo
i,erifyit is accurate. I agree to comply with all applicable local
ordinances and state laws relating
to building cons . I authorize repres s o Cupertino to enter the above -identified property for inspection purposes.
Signature of ApplicanUAgent:
Date: �2
S
PL F.p ]FORMATION REQUIRED{''
OFFICE USE ONLI �, 'Sa
OVER THE COUNTER Z,K ",
w �
#,���X%w
❑ ST�.ADARD-0�
a
❑ LARGE'
A7EPA7iscApp_2011.doc revised 06121/11
CITY OF CUPERTINO
FM -7 FEE ESTIMATOR -BUILDING DIVISION
APPLIANCE / EQUIP TYPE
ADDRESS: 850 Lily Ave
DATE: 07/01/2015
REVIEWED BY: Sean
UNITS
APN:
BP#:
`VALUATION: 1$6,650
*PERMIT TYPE: Mechanical Permit
PLAN CHECK TYPE: Alteration / Addition / Repair
PRIMARY SFD or Duplex
USE:
#
PENTAMATION FURN/AC
PERMIT TYPE:
WORK
Remove and replace A/C.
SCOPE
C
��Z ppl. r,, ;Sp Fe
APPLIANCE / EQUIP TYPE
FEE ID
Plunch. Plan Check
QTY
UNITS
BP FEES
Fhlr Permir Fee -
A/C Units (<=1 OK cfm)
1BREMAIR
Other Llec. Insp.
1
#
$72
Permit Fee:
C
��Z ppl. r,, ;Sp Fe
PME Unit Fee:
$72.00
PME Permit Fee:
$48.00
Construction Tats:
Administrative Fee: IADMIN
$45.00
Work Without Permit? o Yes 0 No
$0.00
TOTALS:
Travel Documentation Fee: ITRA VDOC
$72.00
Strong Motion Fee: IBSEISMICR
NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School
District, etc). TheseJees are based on the preliminary information available and are only an estimate. Contact the Deptjor addh 7 info.
FEE ITEMS (Fee Resolution 11-053 E ' 711.'13)
Mech. Plan Check 0.0 1 hrs $0.00
Plunch. Plan Check
Elec. Plan Check
Mech. Permit Fee: IMPERMIT
I'lurrrt,
Fhlr Permir Fee -
Other Mech. Insp.0.0 hrs $48.00
other Plumb Insp.L-i I
Other Llec. Insp.
Mech. Insp. Fee:
Phuctb. Insp. /*,ee
Elec. Insp. Fee:
NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School
District, etc). TheseJees are based on the preliminary information available and are only an estimate. Contact the Deptjor addh 7 info.
FEE ITEMS (Fee Resolution 11-053 E ' 711.'13)
FEE
QTY/FEE
MISC ITEMS
PME Plan Check:
$0.00
Permit Fee:
C
��Z ppl. r,, ;Sp Fe
PME Unit Fee:
$72.00
PME Permit Fee:
$48.00
Construction Tats:
Administrative Fee: IADMIN
$45.00
Work Without Permit? o Yes 0 No
$0.00
4(1VU11(Vd PlarminLr Fees
Travel Documentation Fee: ITRA VDOC
$48.00
Strong Motion Fee: IBSEISMICR
$0.86
Select an Administrative Item
Bldg Stds Commission Fee: IBCBSC
$1.00
SUBTOTALS:
$214.86
$0.00 TOTAL FEE:
$214.86
Revised: 05/07/2015
CERTIFICATE OF COMPLIANCE
Alterations to Space Conditioning Systems (formerly CF -IR -ALT -HVAC)
Project Name:
850 Lily Ave I Date Prepared:
CF1R-ALT-02-E
(Page 1 of 3 )
2015-06-15
A. General Information
CF1R-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be
documented, use one CF1R-ALT-02 document for each dwelling unit.
O1
Project Name
850 Lily Ave
02
Date Prepared
2015-06-15
03
Project Location
850 Lily Ave
04
Building Type
Single family
05
CA City
Cupertino
06
Dwelling Unit Name
850 Lily Ave
07
Zip Code
95014
08
Dwelling Unit Conditioned
2300
Installing
Installing
Installing
Floor Area (ft2)
Location or Area
by this SC
ducted
containing
system
Number of space conditioning
entirely new
09
Climate Zone
4
10
(SC) systems in this dwelling
1
component?
components?
feet of ducts?
duct system?
unit.
Alteration Type
B. Space Conditioning (SC) System Information
01
02
03
04
05
06
07
08
09
10
Is the SC
Installing a
SC System
SC System
CFA served
system a
refrigerant
Installing new SC
Installing
Installing
Installing
Identification or
Location or Area
by this SC
ducted
containing
system
more than 40
entirely new
entirely new
Name
Served
System (ft2)
system?
component?
components?
feet of ducts?
duct system?
SC system?
Alteration Type
5 Ton A/C
Whole Home
2300
Yes
Yes
Yes
No
No
No
Altered space
Condenser
conditioning system
C. Extension of Existing Duct System, Greater Than 40 Feet (Section150.2(b)1Diib)
This section does not apply to this project.
Registration Number: 215-A0159896A-000000000-0000
Registration Date/Time
2015 -OC -15 17:03:29
HERS Provider: CalCERTS
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2014-03-31 Report Generated: 2015-06-15 17:03:36
Schema Version: O.S55SDD
CERTIFICATE OF COMPLIANCE CF111-ALT-024
Alterations to Space Conditioning Systems (formerly CF -IR -ALT -HVAC) (Page 2 of 3 )
D. Altered Space Conditioning System (Sections 150.2(b)lE and F)
01
02
03
04
05
06
07
08
09
10
11
12
Heating
Cooling
System
Heating
Altered
Heating
Minimum
Altered
Cooling
Minimum
Required
New or
Identification
System
Heating
Efficiency
Efficiency
Cooling
Cooling
Efficiency
Efficiency
Thermostat
Replaced
New Duct
or Name
Type
Components
Type
Value
System Type
Components
Type
Value
Type
Duct Length
R -Value
Central
No heating
This field or
This field or
Central split
No cooling
This field or
This field or
This field or
This field or
5 Ton A/C
gas
component
section is not
section is not
AC
component
section is not
section is not
Setback
section is not
section is not
Condenser
furnace
altered
applicable
Pp
a licable
PP
altered
applicable
PP
applicable
PP
applicable
PP
applicable
PP
Required Documentation:
CF2R-MCH-01-E - Space Conditioning Systems Ducts and Fans
-Duct insulation requirement for new plenums: R6.
CF2R-MCH-20-H & CF3R-MCH-20-H — Duct Leakage testing required when heating or cooling components are installed in ducted systems, or when more than 40 ft of duct length is replaced.
-Leakage rate compliance: S 15%, or 5 10% leakage to outside, or seal all accessible leaks.
CF2R-MCH-25-H & CF3R-MCH-25-H Refrigerant Charge Verification required when refrigerant containing components are installed or altered (applicable in C2 2, 8-15).
CF2RCF3R-MCH-23 & CF3R-MCH-23 Air Flow a 300 CFM/ton required when MCH -25 is required.
Exceptions:
-Duct systems registered with HERS provider as previously sealed are exempt from MCH -20 Duct Leakage Testing requirements.
-Heating-only systems and Air Handler/Furnace changes do not require verification of Air Flow MCH -23, or Refrigerant Charge MECH-25.
-Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH -20 Duct Leakage Testing requirements.
E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150.2(b)1Diia and 150.2(b)lE, F)
This section does not apply to this project.
F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C)
This section does not apply to this project.
Registration Number: 215-A0159896A-000000000-0000
Registration Date/Time:
2015-06-15 17:03:29
HERS Provider: Ca10ERTS
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2014-03-31 Report Generated: 2015-06-15 17:03:36
Schema Version: 0.555SDD
CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC) (Page 3 of 3 )
Documentation Author's Declaration Statement
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature: nW jl�� �� . D
eC7i
Frederick, Alanna
CQV c`f/
Company:
Signature Date:
CALIFORNIA DELTA MECHANICAL INC
2015-06-15 17:03:29
Address:
CEA/ HERS Certification Identification (if applicable):
1235 GRAND AVE
City/State/Zip:
Phone:
SPRING VALLEY CA 91977
(480) 898-0007
Responsible Person's Declaration statement
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer).
3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the
requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
S. I will ensure that a registered copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable
ng owner at occupancy.
inspections. I understand that a registered copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building
Responsible Designer Name:
Responsible Designer Signature: —
/W&U
Frederick, Alanna
CQ
v�CC19?/?,C� Cl'
Company:
Date Signed:
CALIFORNIA DELTA MECHANICAL INC
2015-06-15 17:03:29
Address:
License:
1235 GRAND AVE
811114
City/State/Zip:
Phone:
SPRING VALLEY CA 91977
(480) 898-0007
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration Provider responsibility for the accuracy of the information.
Registration Number: 215-A0159896A-000000000-0000 Registration Date/Time: 2015-06-15 17:03:29 HERS Provider: CaICERTS
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2014-03-31 Report Generated: 2015-06-15 17:03:36
Schema Version: 0.555SDD
SMOKE / CARBON MONOXIDE ALARMS
OWNER CERTIFICATE OF COMPLIANCE
COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION
10300 TORRE AVENUE • CUPERTINO, CA 95014-3255
(408) 777-3228 • FAX (408) 777-3333 • buildingicDcupertino.org
_ Permit No. I Sol ouy
Address �J 0 �`� Vz , Cy P Z -k -T/ ,t -J o # of Alarms Smoke: 71 Carbon Monoxide:
PURPOSE
This affidavit is a self -certification for the installation of all required Smoke and Carbon Monoxide Alarms for
compliance with 2013 CRC Section R314, 2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for
inspections are required.
GENERAL INFORMATION
Existing single-family and multi -family dwellings shall be provided with Smoke Alarms and Carbon
Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds
$1000.00, CRC Section R314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon.
Monoxide Alarms be installed in the following locations:
AREA
SMOKE ALARM
CO ALARM
Outside of each separate sleeping area in the immediate vicinity of the
bedroom(s)
X
X
On every level of a dwelling unit including basements
X
X
Within each sleeping room
X
Carbon Monoxide alarms are not required in dwellings which do not contain fuel -burning appliances and that
do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with
CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal.
Power Supply: In dwelling units with no commercial power supply, alarm(s) may be solely battery operated.
In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do
not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl
space. Refer to CRC Section 8314 and CBC Sections 907.2.11.4 and 420.6.2. An electrical permit is required for
alarms which must be connected to the building wiring.
As owner of the above -referenced property, I hereby certify that the alarm(s) referenced above has/have been
installed in accordance with the manufacturer's instructions and in compliance with the California Building
and California Residential Codes. The alarms have been tested and are operational, as of the date signed
below.
1 have read and agree to cqpply wit the ns of this statement
Owrn�er (or Ow(n�jerr Agent's') Name:) )
......................................... Date:�/!
Vj
Contractor Name:
Signature........ .............................. ............................. Lic.#...................................... Date:...................
Smoke and CO form.doc revised 03/18114
CUPERTINO
Owner Name
WATER -CONSERVING PLUMBING FIXTURES
OWNER CERTIFICATE OF COMPLIANCE
COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION
10300 TORRE AVENUE • CUPERTINO, CA 95014-3255
(408) 777-3228 • FAX (408) 777-3333 • building(W-cupertino.org
Address RAJ L I L`(1/C i�P�k'7/)ID �.�'J
PERMIT CANNOT BE l
HAS BEEN SICZ
FILE
�Vll
,67000
'D AND COMPLETED UNTIL THIS CERTIFICATE
) RETURNED TO THE BUILDING DIVISION
Please refer to the attached California Civil Code Sections 1101.1 — 1101.8 which are part of this Certification form.
Is your real property a registered historical site?
❑ Yes Civil Code Sections 110 1. 1 u 101.8 do not apply. Sign below and skip the rest of the form.
Owner' Signature: Date:
VNo Go to Question 2.
Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its
plumbing, installation of water -conserving plumbing fixtures is not technically feasible?
❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply.
❑ The licensed plumber's certification has been provided to the Building Division.
Sign below and skip the rest of the form.
Owner' Signature: Date:
VNo Go to Question 3.
Is water service permanently disconnected for your building?
❑ Yes Civil Code Sections 110 .1 thro h 01.8 do not apply. Sign below and skip the rest of the form.
Owner' Signature: Date:
U/No Go to Question 4.
Is your real property built and available for use or occupancy on or before January 1, 1994?
❑ No My real property is built and available for use or occupancy after January 1, 1994.
Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form.
Owner' Signature: Date:
VYes My real property is built and available for use or occupancy on or before January 1, 1994.
Civil Code Sections 1101.1 through 1101.8 apply. Refer to the attached.
My property is a single-family residential real property. See Civil Code Section 1101.4.
On and after January 1, 2014, building alterations or improvements shall require all non-compliant plumbing
fixtures to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1,
2017, all non-compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless
of whether property undergoes alterations or improvements).
❑ My property is a multifamily residential real property. See Civil Code Section 1101.5.
On and after January 1, 2014, specified building alterations or irnprovements shall require non- compliant
plumbing fixtures to be replaced with water -conserving plumbing fixtures.
On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water -
conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or
improvements).
❑ My property is a commercial real property. See Civil Code Section 1101.5.
On and after January 1, 2014, specified building alterations or improvements shall require non- compliant
plumbing fixtures to be replaced with water -conserving plumbing fixtures.
SB407 2015.doc revised 02/04/15
On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water- conserving
plumbing fixtures throughout the building (regardless of whether property undergoes alterations or
improvements).
I/We, the owner(s) of this property, certify under penalty of perjury that non-compliant plumbing fixtures will be replaced
prior to date specified above with water -conserving plwnbing fixtures in accordance with Civil Code Sections 1101.1 through
1101.8, the current California Plumbing Code and Californi Gree 1.ding Standards Code, and manufacturer's installation
requirements, and that the water -conserving p bins comply ith the requirements as indicated in the table below.
Owner's (or Owner Agent's) Signature: Date: /�
Upon completing and signing this Certificate, please return it to the Building Division in order to final your permit.
1. If the existing plumbing fixture water usage/flow rate is equal to or lower than the figure shown, it is not required to be upgraded.
SB407 2015. doe revised 02/04/15
Non -Compliant
Water -Conserving Plumbing Fixture
PlumbingFixture
(Fixture Complying with Current Code Applicable to New Construction)
Maximum
Water Usage/Flow
Rate
Fixture Type
Water Usage
2013 CPC Ch. 4
2013 CPC Ch. 4
2013 CPC Ch. 4
/Flow Rate
2013 CALGreen Div. 4.3
2013 CALGreen Div. 4.3
2013 CALGreen Div. 5.3
Single -Family
Multi -Family
Commercial
Residential
Residential
Water Closets
Exceed 1.6
Single flush toilets: 1.28 gallons/flush
(Toilets)
Gallons/flush
Dual flush toilets: 1.28 gallons/flush effective flush volume (the composite,
average flush volume of two reduced flushes and one full flush
Urinals
Exceed 1.0
0.5 gallons/flush
Gallons/flush
Showerheads
Exceed 2.5
2.0 gallons per minute @ 80 psi. Also certified to the performance criteria of
gallons per minute
U.S. EPA WaterSense Specification for Showerheads
(A hand-held shower is considered a showerhead.)
For multiple showerheads serving one shower, the combined flow rate of all
showerheads and/or other shower outlets controlled by a single valve shall not
exceed 2.0 gallons per minute @ 80 psi, or the shower shall be designed to
allow only one shower outlet to be in operation at a time.
Faucets -
Exceed 2.2 gallons
Maximum 1.5 gallons per
Within units:
0.5 gallons per minute @ 60
Lavatory
per minute
minute @ 60 psi; minimum
Maximum 1.5 gallons
psi
Faucets
0.8 gallons per minute @
per minute @ 60 psi;
20 psi
minimum 0.8 gallons
per minute @ 20 psi
In common and public
use areas: 0.5 gallons
per minute @ 60 psi
1.8 gallons per minute
60 psi
Faucets -
Exceed 2.2 gallons
1.8 gallons per minute @
1.8 gallons per minute
1.8 gallons per minute @ 60
Kitchen
per minute
60 psi
@ 60 psi
psi
Faucets
May temporarily increase
May temporarily
up to 2.2 gallons per
increase up to 2.2
minute @ 60 psi, and must
gallons per minute @
default to maximum
60 psi, and must
1.8 gallons per minute @
default to maximum
60 psi
1.8 gallons per minute
Where faucets meeting
@ 60 psi
the above are unavailable,
Where faucets meeting
aerators or other means
the above are
may be used to achieve
unavailable, aerators or
reduction.
other means may be
used to achieve
reduction.
1. If the existing plumbing fixture water usage/flow rate is equal to or lower than the figure shown, it is not required to be upgraded.
SB407 2015. doe revised 02/04/15