Loading...
15060095IS1 Address SMOKE / CARBON MONOXIDE ALARMS OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building cDcupertino.org 9c)(010 MF arms Carbon M PURPOSE This affidavit is a self -certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R314, 2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single-family and multi -family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds $1000.00, CRC Section R314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations: AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of the bedroom(s) X X On every level of a dwelling unit including basements X X Within each sleeping room X Carbon Monoxide alarms are not required in dwellings which do not contain fuel -burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. Power Supply: h -t dwelling units with no commercial power supply, alarm(s) may be solely battery operated. In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl space. Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2. An electrical permit is required for alarms which must be connected to the building wiring. As owner of the above -referenced property, I hereby certify that the alarm(s) referenced above has/have been installed in accordance with the manufacturer's instructions and in compliance with the California Building and California Residential Codes. The alarms have been tested and are operational, as of the date signed below. I have read and aciree to comply with the terms and conditions of this statement Owner (or fOwner Ag t's) Name: l M(s GrL , Si nature...... ..........................`.. .............. Date: ... .. .. Contractor Name: Sin .... ............. ..... .......Lic.# .....501H..'? ........... Date: �/ V Smoke and CO form.doc revised 03/18/14 CUPERTINO Owner Name Address aVF WATER -CONSERVING PLUMBING FIXTURES OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISIONILE r 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 �/ 1 _(408()777-3228 • FAX (408) 777-3333 • build ing(alcupertino.org M1 Pen -nit No. 9 S8 PERMIT CANNOT BE FINALED AND COMPLETED UNTIL THIS CERTIFICATE HAS BEEN SIGNED AND RETURNED TO THE BUILDING DIVISION Please refer to the attached California Civil Code Sections 1101.1 — 1101.8 which are part of this Certification form. 1. Is your real property a registered historical site? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form. Owner' Signature: Date:_ -7/045- _ �No Go to Question 2. r -� (/' J 2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its plumbing, installation of water -conserving plumbing fixtures is not technically feasible? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. ❑ The licensed plumber's certification has been provided to the Building Division. Sign below and skip the rest of the form. / Owner' Signature: -,; No Go to Question 3. Date: 3. Is water service permanently disconnected for your building? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form. Owner' Signature: No Go to Question 4. �ALI Date: 4. Is your real property built and available for use or occupancy on or before January 1, 1994? ❑ No My real property is built and available for use or occupancy after January 1, 1994. Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form. 'Q Owner' Signature: �,� Date: Q/ Yes My real property is built and available for use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101.8 apply. Refer to the attached. ' /My property is a single family residential real property. See Civil Code Section 1101.4. On and after January 1, 2014, building alterations or improvements shall require all non-coinpliant plumbing fixtures to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non-compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements). ❑ My property is a multifamily residential real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water - conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). ❑ My property is a commercial real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or iunprovernents shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. SB4072015.doc revised 02/04/15 On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). I/We, the owner(s) of this property, certify under penalty of perjury that non-compliant plumbing fixtures will be replaced prior to date specified above with water -conserving plumbing fixtures in accordance with Civil Code Sections 110 1. 1 through 1101.8, the current California Plumbing Code and California Green Building Standards Code, and manufacturer's installation requirements, and that the water -conserving pl fixtures comply with the requirements as indicated in the table below. Owner's (or Owner Agent's) Signature: - Date: -4 ziAt- Upon completing and signing this Certificate, please return it to the Building Division in order to final your permit. 1. If the existing plumbing fixture water usage/flow rate is equal to or lower than the figure shown, it is not required to be upgraded. SB407 2015.doc revised 02/04/15 Non -Compliant Water -Conserving Plumbing Fixture PlumbingFixture (Fixture Complying with Current Code Applicable to New Construction) Maximum Water Usage/Flow Rate Fixture Type Water Usage 2013 CPC Ch. 4 2013 CPC Ch. 4 2013 CPC Ch. 4 /Flow Rate 2013 CALGreen Div. 4.3 2013 CALGreen Div. 4.3 2013 CALGreen Div. 5.3 Single -Family Multi -Family Commercial Residential Residential Water Closets Exceed 1.6 Single flush toilets: 1.28 gallons/flush (Toilets) Gallons/flush Dual flush toilets: 1.28 gallons/flush effective flush volume (the composite, average flush volume of two reduced flushes and one full flush Urinals Exceed 1.0 0.5 gallons/flush Gallons/flush Showerheads Exceed 2.5 2.0 gallons per minute @ 80 psi. Also certified to the performance criteria of gallons per minute U.S. EPA WaterSense Specification for Showerheads (A hand-held shower is considered a showerhead.) For multiple showerheads serving one shower, the combined flow rate of all showerheads and/or other shower outlets controlled by a single valve shall not exceed 2.0 gallons per minute @ 80 psi, or the shower shall be designed to allow only one shower outlet to be in operation at a time. Faucets — Exceed 2.2 gallons Maximum 1.5 gallons per Within units: 0.5 gallons per minute @ 60 Lavatory per minute minute @ 60 psi; minimum Maximum 1.5 gallons psi Faucets 0.8 gallons per minute @ per minute @ 60 psi; 20 psi minimum 0.8 gallons per minute @ 20 psi In common and public use areas: 0.5 gallons per minute @ 60 psi 1.8 gallons per minute 60 psi Faucets — Exceed 2.2 gallons 1.8 gallons per minute @ 1.8 gallons per minute 1.8 gallons per minute @ 60 Kitchen per minute 60 psi @ 60 psi psi Faucets May temporarily increase May temporarily up to 2.2 gallons per increase up to 2.2 minute @ 60 psi, and must gallons per minute @ default to maximum 60 psi, and must 1.8 gallons per minute @ default to maximum 60 psi 1.8 gallons per minute Where faucets meeting @ 60 psi the above are unavailable, Where faucets meeting aerators or other means the above are may be used to achieve unavailable, aerators or reduction. other means may be used to achieve reduction. 1. If the existing plumbing fixture water usage/flow rate is equal to or lower than the figure shown, it is not required to be upgraded. SB407 2015.doc revised 02/04/15 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 1 of 7 ) Project Name: Kim, Mishael Enforcement Agency: City of Cupertino Permit Number: 15060095 Dwelling Address: 20614 Mapletree Place City: Cupertino Zip Code: 95014 A. General Information 01 Dwelling Unit Name Kim, Mishael 02 Climate Zone 4 07 Dwelling Unit Conditioned Floor Area 09 10 Number of space conditioning (SC) 03 (ft2) 1385 04 systems being altered in this dwelling 1 SC System SC System unit. system a 05 Certificate of Compliance Type Prescriptive alterations (CF1R-ALT) 06 Method used to calculate HVAC loads NotApplicableEquipmentChan 07 Calculated dwelling unit Sensible This field or section is not applicable 08 Calculated Dwelling Unit Heating Load This field or section is not applicable than 40 feet of Cooling Load (Btuh) entirely new (Btuh) Served MCH -01b Prescriptive Alterations - Space Conditioning Systems Ducts and Fans B. Space Conditioning (SC) System Information 01 02 03 04 05 06 07 08 09 10 CFA served Is the SC Installing a Installing SC System SC System by this SC system a refrigerant Installing new SC Installing more entirely Installing Identification or Location or Area System ducted containing system than 40 feet of new duct entirely new Name Served (ft2) system? component? components? ducts? system? SC system? Alteration Type Altered space Kim, Mishael Whole house 1385 Yes Yes Yes No No No conditioning system Registration Number: 215-A0151803A-M0100002A-0000 Registration Date/Time 2015-06-15 15:59:21 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2014 -OS -13 Report Generated: 2015-06-15 15:58:00 Schema Version: 0.555SDD LjL 1-1 CERTIFICATE OF INSTALLATION CF2R-MCH-0I-E Space Conditioning Systems, Ducts, and Fans (Page 2 of 7 ) C. Space Conditioning (SC) System Alterations Compliance Information O1 02 03 04 05 06 07 08 09 10 11 12 13 Heating Efficiency Type Heating Efficiency Value Heating Unit Manufacturer Heating Unit Model Number Heating Unit serial number Rated Heating Capacity, Output (BTUH) Kim, Mishael AFUE 0.8 Bryant 310JAV024045 0815A14878 Central Fan Notes: Integrated Heating Cooling New or (CFI) System Altered Heating Minimum Altered Cooling Minimum Required Replaced New Ventilation Identification Heating Heating Efficiency Efficiency Cooling Cooling Efficiency Efficiency Thermostat Duct Duct System or Name System Type Component Type Value System Type Component Type Value Type Length R -Value Status This field All new All new N/A - no or Kim, Mishael Central gas heating AFUE 0.8 Central cooling SEER 13 Setback ducts sectio Not a CFI furnace componen split AC components replaced n is system is not applic able D. Installed Heating Equipment information 01 02 03 04 05 06 07 System Identification or Name Heating Efficiency Type Heating Efficiency Value Heating Unit Manufacturer Heating Unit Model Number Heating Unit serial number Rated Heating Capacity, Output (BTUH) Kim, Mishael AFUE 0.8 Bryant 310JAV024045 0815A14878 45000 Notes: Registration Number: 215-A0151803A-M0100002A-0000 Registration Date/Time 2015-06-15 15:59:21 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2014 -OS -13 Report Generated: 2015-06-15 15:58:00 Schema Version: 0.555SDD CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 3 of 7 ) E. Installed Cooling Equipment information: O1 02 03 04 05 06 07 08 Condenser or Package Unit Condenser or Condenser or Condenser or System Rated Cooling Condenser Rated System Identification Cooling Efficiency Coaling Efficiency Package Unit Package Unit Package Unit Capacity at Design Nominal Capacity or Name Type Value Manufacturer Model Number Serial Number Conditions (BTUH) (ton) Kim, Mishael SEER 13 Bryant 113ANOA02400 4114E15509 24000 2 Notes: F. Extension of Existing Duct System, Greater Than 40 Feet This section does not apply to this project. G. Installed Duct System information This section does not apply to this project. H. Installed Air Filter Device Information This section does not apply to this project. I. Air Filter Device Requirements This section does not apply to this project. Registration Number: 215-A0151803A-M0100002A-0000 Registration Date/Time 2015-06-15 15:59:21 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2014-05-13 Report Generated: 2015-06-15 15:58:00 Schema Version: 0.555SDD CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 4 of 7 ) J. HERS Verification Requirements 01 02 03 04 05 06 07 08 09 10 MCH20 MCH21 MCH22 MCH23 MCH25 MCH28 Exemption from Minimum Exemption R -Value for AHU Fan AHU SC System SC System From Duct Duct Ducts In Ducts Located Efficacy Airflow Identification or Location or Area Leakage Leakage Conditioned In Cond Space (W per Rate (cfm Refrigerant Return Duct Design Name Served Requirements Test Space Verification cfm) per ton) Charge Table 150.0-C or D Existing duct system is Not Kim, Mishael Whole house insulated or No No No No No No applicable sealed with asbestos Registration Number: 215-A0151803A-M0100002A-0000 Registration Date/Time: 2015-06-15 15:59:21 HERS Provider: CalCERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2014-05-13 Report Generated: 2015-06-15 15:58:00 Schema Version: 0.555SDD CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 5 of 7 ) K. Space Conditioning Systems, Ducts and Fans Mandatory Requirements and Additional Measures Note: Additional mandatory requirements from Section 150.0 that are not listed here may be applicable to some systems. These requirements may be applicable to only newly installed equipment or portions of the system that are altered. Existing equipment may be exempt from these requirements. Heating Equipment 01 Equipment Efficiency: All heating equipment must meet the minimum efficiency requirements of Section 110.1 and Section 110.2(a) and the Appliance Efficiency Regulations. 02 Controls: All unitary heating systems, including heat pumps, must be controlled by a setback thermostat. These thermostats must be capable of allowing the occupant to program the temperature set points for at least four different periods in 24 hours. See Sections 150.0(1), 110.2(b). 03 Sizing: Heating load calculations must be done on portions of the building served by new heating systems to prevent inadvertent undersizing or oversizing. See sections 150.0(h)1 and 2). 04 Furnace Temperature Rise: Central forced -air heating furnace installations must be configured to operate at or below the furnace manufacturer's maximum inlet -to -outlet temperature rise specification. See Section 150.0(h)4. 05 Standby Losses and Pilot Lights: Fan -type central furnaces may not have a continuously burning pilot light. Section 110.5 and Section 110.2(d). Cooling Equipment 06 Equipment Efficiency: All cooling equipment must meet the minimum efficiency requirements of Section 110.1 and Section 110.2(a) and the Appliance Efficiency Regulations. 07 Refrigerant Line Insulation: All refrigerant line insulation in split system air conditioners and heat pumps must meet the R -value and protection requirements of Section 150.0(j)2 and 3, and Section 1S0.0(m)9. 08 Condensing Unit Location: Condensing units shall not be placed within five (5) feet of a dryer vent outlet. See Section 150.0(h)3A. 09 Sizing: Cooling load calculations must be done on portions of the building served by new cooling systems to prevent inadvertent undersizing or oversizing. See Section 150.0(h)1 and 2. Air Distribution System Ducts, Plenums and Fans 10 Insulation: In all cases, unless ducts are enclosed entirely in directly conditioned space, the minimum duct insulation value is R-6. Note that higher values may be required by the prescriptive or performance requirements. See Section 150.0(m)1. Registration Number: 215-A0151803A-M0100002A-0000 Registration Date/Time: 2015-06-15 15:59:21 HERS Provider: CaICERTS CA Building Energy Efficiency Standards- 2013 Residential Compliance Report Version: 2014-05-13 Report Generated: 2015-06-15 15:58:00 Schema Version: 0.555SDD CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 6 of 7 ) K. Space Conditioning Systems, Ducts and Fans Mandatory Requirements and Additional Measures Note: Additional mandatory requirements from Section 150.0 that are not listed here may be applicable to some systems. These requirements may be applicable to only newly installed equipment or portions of the system that are altered. Existing equipment may be exempt from these requirements. Connections and Closures: All installed air -distribution system ducts and plenums must be, sealed and insulated to meet the requirements of CMC Sections 601.0, 11 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006: Supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing in accordance with the requirements of Reference Residential Appendix RA3.1.4.3.8. Heat Pump Thermostat 12 A thermostat shall be installed that meets the requirements of Section 110.2(b) and Section 110.2(c). 13 The thermostat shall be installed in accordance with the manufacturers published installation specifications 14 First stage of heating shall be assigned to heat pump heating. 15 Second stage back up heating shall be set to come on only when the indoor set temperature cannot be met. The responsible person signature on this compliance document affirms that all applicable requirements in this table have been met. Registration Number: 215-AO151803A-MO100002A-0000 Registration Date/Time 2015-06-15 15:59:21 HERS Provider: CalCERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2014-05-13 Report Generated: 2015-06-15 15:58:00 Schema Version: O.SSSSDD CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 7 of 7 ) Documentation Author's Declaration Statement 1. 1 certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Sanchez, Rafaelsl11orlc l Company: Signature Date: PELLE HEATING & AIR INC 2015-06-15 15:59:21 Address: CEA/ HERS Certification Identification (if applicable): 179 SAN RAMON DRIVE City/State/Zip: Phone: SAN JOSE CA 95111 1(408) 978-7060 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attest to the declarations in this statement (responsible builder/installer), otherwise I am an authorized representative of the responsible builder/installer. 3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations, and the installation conforms to the requirements given on the plans and specifications approved by the enforcement agency. 4. 1 reviewed a copy of the Certificate of Compliance approved by the enforcement agency that identifies the specific requirements for the scope of construction or installation identified on this Certificate of Installation, and I have ensured that the requirements that apply to the construction or installation have been met. 5. 1 will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Responsible Builder/Installer Signature: Sanchez, Rafael _ j4l� Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Position With Company (Title): PELLE HEATING & AIR INC Manager Address: CSLB License: 179 SAN RAMON DRIVE 809887 City/State/Zip: 1(408) Phone: Date Signed: SAN JOSE CA 95111 978-7060 12015-06-15 15:59:21 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 215-A0151803A-M0100002A-0000 Registration Date/Time: 2015-06-15 15:59:21 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2014-05-13 Report Generated: 2015-06-15 15:58:00 Schema Version: 0.555SDD M L A. General Information CFiR-ALT 02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one CF1R-ALT 02 document for each dwelling unit. 01 Project Name Kim, Mishael 02 Date Prepared 2015-06-08 03 Project Location 20614 Mapletree Place 04 Building Type Multi -family 05 CA City Cupertino 06 Dwelling Unit Name Kim, Mishael 07 Zip Code 95014 08 Dwelling Unit Conditioned 1385 Installing Insxalling Installing Floor Area (ft2) Location or Area by this SC ducted containing system Number of space conditioning entirely new 09 Climate Zone 4 10 (SC) systems in this dwelling 1 component? components? feet of ducts? duct system? unit. Alteration Type B. Space Conditioning (SC) System Information x. ..x 01 02 03 � 09 10 Is the SC Installing a SC System SC System CFA served system a refnge�ant �Instalhrig>new SG Installing Insxalling Installing Identification or Location or Area by this SC ducted containing system more than 40 entirely new entirely new Name Served System (ft2) system? component? components? feet of ducts? duct system? SC system? Alteration Type Altered space Kim, Mishael Whole house 1385 Yes Yes Yes No No No conditioning system C. Extension of Existing Duct System, Greater Than 40 Feet (Section 150.2(b)1Diib) This section does not apply to this project. Registration Number: 215-A0151803A-000000000-0000 Registration Date/Time: 2015-06-08 14:45:16 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2014-03-31 Report Generated: 2015-06-08 14:38:06 Schema Version: 0.555SDD CERTIFICATE OF COMPLIANCE CUR -ALT -024 Alterations to Space Conditioning Systems (formerly CF -IR -ALT -HVAC) (Page 2 of 3 ) D. Altered Space Conditioning System (Sections 150.2(b)1E and F) 01 02 03 04 05 06 07 08 09 10 11 12 Heating Cooling System Heating Altered Heating Minimum Altered Cooling Minimum Required New or Identification System Heating Efficiency Efficiency Cooling Cooling Efficiency Efficiency Thermostat Replaced New Duct or Name Type Components - Type Value -System Type- -Components Tgpe -Value -Type Duct Length R -Value Central gas All new Central split All new This field or This field or Kim, Mishael furnace heating AFUE 0.8 AC cooling SEER 13 Setback section is not section is not components components applicable applicable Required Documentation: CF2R-MCH-01-E - Space Conditioning Systems Ducts and Fans -Duct insulation requirement for new plenums: R6. CF2R-MCH-20-H & CF3R-MCH-20-H — Duct Leakage testing required when heating or cooling components are installed in ducted systems, or when more than 40 ft of duct length is replaced. -Leakage rate compliance: 515%, or 510% leakage to outside, or seal all accessible leaks. CF2R-MCH-25-H & CF3R-MCH-25-H Refrigerant Charge Verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15). CF2RCF3R-MCH-23 & CF3R-MCH-23 Air Flow -e 300 CFM/ton required when MCH -25 is required. Exceotions: -Duct systems registered with HERS provider as previously sealed are exempt frof MCH -20 Duct Leakage Testing requirements Y ' -Heating-only systems and Air Handler/Furnace changes do not require verification of Air Flow MCH=23;;or Refrigerant Char'ge MECH-25,. Existing duct systems constructed, insulated or sealed with asbestos are exempt -from MCH -20 Duc4,Leakage Testing regwremerits. E. Entirely New or Complete Replacement Duct System, with br wAthout1quipment Changeouts(Secttons 150 2(b)1Duaaand,150.2(b)1E, F) This section does not apply to this project. F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C) This section does not apply to this project. Registration Number: 215-A0151803A-000000000-0000 Registration Date/Time: 2015-06-08 14:45:16 HERS Provider: CalCERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2014-03-31 Report Generated: 2015-06-08 14:38:06 Schema Version: 0.555SDD CERTIFICATE OF COMPLIANCE CFIR-ALT 02-E Alterations to Space Conditioning Systems (formerly CF -1R -ALT HVAC) (Page 3 of 3 ) Documentation Author's Declaration Statement 1.1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: i�C��aPi(/��LC%JI�FJZ Sanchez, Rafael Company: Signature Date: PELLE HEATING & AIR INC -2015-06-08-1.4:45:16 Address: CEA/ HERS Certification Identification (if applicable): 179 SAN RAMON DRIVE City/State/Zip: Phone: SAN JOSE CA 95111 (408) 978-7060 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate bf Compliance are'consistent.with'the information provided on. otherapplicatile compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval,with this building permit application. 5. 1 will ensure that a registered copy of this Certificate W. Compliance skall be`made available with the building permit(s) issued forthe=building, and made available to the"einforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Compliance is,reauired to be included with the,documentation,the.builder provides to,the building owner at occupancy. Responsible Designer Name: Responsible Designer Signature: '" Sanchez, Rafael i�V�6Y(/�lL3LC�lLPJL Company: Date Signed: PELLE HEATING & AIR INC 2015-06-08 14:45:16 Address: License: 179 SAN RAMON DRIVE 809887 City/State/Zip: Phone: SAN JOSE CA 95111 (408) 978-7060 Digitally signed by Ca/CERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 215-A0151803A-000000000-0000 Registration Date/Time: 2015-06-08 14:45:16 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2014-03-31 Report Generated: 2015-06-08 14:38:06 Schema Version: 0.555SDD