15070056�i CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 1591 ASTER LN CONTRACTOR: VALLEY HEATING & PERMIT NO: 15070056 COOLING OWNER'S NAME: TSAO TED AND EVA 1171 N 4TH ST DATE ISSUED: 07/08/2015 OWNER'S PHONE: 4088861113 SAN JOSE, CA 95112 PHONE NO: (408)294-6290 ❑ CENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL COMMERCIAL q (�REMOVE License Class L—ic. #r�✓ y AND REPLACE FURNACE AND A/C. �f v Contractor Date I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Sq. Ft Floor Area: Valuation: $10860 I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this APN Number: 36624012.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS OF PERMIT ISSUANCE OR to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save 180 DAYS FROM LAST CALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the Issued by: C moi/✓ �r�� Date: granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section RE -ROOFS: 9.18. � Signature Date� All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. ❑ OWNER -BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) I, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. 1 will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(a) should I store or handle hazardous I have and will maintain a Certificate of Consent to self -insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and I have and will maintain Worker's Compensation Insurance, as provided for by the Health & Safety Code, Sections 5505, 25533, and 25534. Section 3700 of the Labor Code, for the performance of the work for which this / Owner or authorized agent: � Date:—21& permit is issued. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's CONSTRUCTION LENDING AGENCY Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section Licensed Professional 9.18. Signature Date GENERAL PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 Rn (408) 777-3228 • FAX (408) 777-3333 • building(a1cupertino.orq 1���aoP MISC rj(,:2 ❑ PLUMBING MECHANICAL ❑ ELECTRICAL ❑ MISCELLANEOUS PROJECT ADDRESS L APN R/7_ C/ OWN'ERNAME ! r �^J PHONE YOK V E-MAIL STREET ADDRESS f V ( J / �L (/ CITY, STATE, ZIP �f FAX PHONE CONTACT NAME U nvLr 1 v E-MAIL STREET ADDRESS CITY, STATE, ZIP FAX ❑ OWNER ❑ ORNTER-BUILDER ❑ OWNER AGENT CONTRACTOR ❑CONTRACTORAGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME- tI Goa 1 LICENSE NUMBER 1 A� < rl l p`) J LICENSE TYPE BUS. LIC N COMPAY NAME E-MAIL FAX y STREET ADDRESS l I IV57 CITY, STATE, ZIP C �I 12 J PHONE ARCHITECT/ENGINTEER NAMEl LICENSE NUMBER BUS. LIC COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE USE OF FD or DUPLEX ❑ MULTI -FAMILY PROJECT IN WILDLAND ❑ YES PROJECT IN YES IS THE BLDG AN ❑ YES BUII-DAG: COMMERCIAL URBAN INTERFACE AREA NO FLOOD ZONE 'O EICHLER HOME? O DESCRIPTION OF WORK j gy TOTAL VALUATION: (� RECEIVED B] ��, x. By my signature below, c rtify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. I have read this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to burd7g construction. I/authorize �representatives of Cupertino to enter the above -r trfiied ro erty for inspection purposes. Signature of Applicant/Agent: -----moi/ r Date: J' SUPPLEMENTAL INFORMATION REQUIRED° " y 41 11DARD� �1 R ' r`(,7 fl = � ���": v ,'A N. 1 ❑ I4A70R MEPAPscApp_201 Ldoc revised 06/21/11 CITY OF CUPERTINO 117"�iVJS31 FF.F F4TIMATOR — BUILDING DIVISION APPLIANCE / EQUIP TYPE ADDRESS: 1591 Astor Lane DATE: 07/08/2015 REVIEWED BY: Sean UNITS APN: BP#: 'VALUATION: 1$10,860 PERMIT TYPE: Mechanical Permit PLAN CHECK TYPE: Alteration / Addition / Repair PRIMARY SFD or Duplex $72 PENTAMATION FURN/AC USE: 1MFR=<100 PERMIT TYPE: WORK Remove and replace furnace and A/C. SCOPE APPLIANCE / EQUIP TYPE FEE ID Plinth. 1'lon Check QTY UNITS BP FEES Permit Fey A/C Units (<=10K cfm) 1BREMAIR Oilier Elec. Insp. 1 # $72 Furnace, Forced -Air 1MFR=<100 Supp/. Insp Fee 1 # $143 PME Unit Fee: $215.00 PME Permit Fee: $48.00 Construction Tax: Administrative Fee: 1ADMIN $45.00 Work Without Permit? 0 Yes Q No $0.00 TOTALS: Travel Documentation Fee: ITRAVDOC $215.00 Strong Motion Fee: 1BSEISMICR NOTE: This estimate does not include fees due to other Departments (Le. Planning, Public worsts, rsre, ,5anirary Sewer usssrics, acnoot n:clwio/n ► Thnco fboe nro hacod not /ho nroliminary inlnrmnhian availahle and are only an estimate. Contact the Dent for addn'l info. FEE ITEMS (Fee Resolution 11-053 E . 711113) Mech. Plan Check 0.0 hrs $0.00 Plinth. 1'lon Check Liec. Plan ChHlElec. Mech. Permit Fee: 1MPERMIT Permit Fey Other Mech. Insp. 0.0 hrs $48.00 Ocher Plum ; ,r,:.,._ Oilier Elec. Insp. Mech. Insp. Tec. 1 himb, Insp. Tee: Elec. Insp. Fee: NOTE: This estimate does not include fees due to other Departments (Le. Planning, Public worsts, rsre, ,5anirary Sewer usssrics, acnoot n:clwio/n ► Thnco fboe nro hacod not /ho nroliminary inlnrmnhian availahle and are only an estimate. Contact the Dent for addn'l info. FEE ITEMS (Fee Resolution 11-053 E . 711113) FEE QTY/FEE MISC ITEMS Plan Check Fee: Sulrpl. PC Fee PME Plan Check: $0.00 Permit Fee: Supp/. Insp Fee PME Unit Fee: $215.00 PME Permit Fee: $48.00 Construction Tax: Administrative Fee: 1ADMIN $45.00 Work Without Permit? 0 Yes Q No $0.00 Advanced Planning Pees: Travel Documentation Fee: ITRAVDOC $48.00 Strong Motion Fee: 1BSEISMICR $1.41 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $1.00 SUBTOTALS: $358.411 $0.00 TOTAL FEE: $358.41 Revised: 07/02/2015 CERTIFICATE OF COMPLIANCE Alterations to Space Conditioning Systems (formerly CF -IR -ALT -HVAC) Project Name: 2015- 0012 Eva Tsao I Date Prepared: CF1R-ALT-02-E (Page 1 of 3 ) 2015-07-02 A. General Information MR -ALT -02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one CF1R-ALT-02 document for each dwelling unit. 01 Project Name 2015- 0012 Eva Tsao 02 Date Prepared 2015-07-02 03 Project Location 1591 Aster Lane 04 Building Type Single family 05 CA City Cupertino 06 Dwelling Unit Name 2015- 0012 Eva Tsao 07 Zip Code 95014 08 Dwelling Unit Conditioned 1700 Installing Installing Installing Floor Area (ft2) Location or Area by this SC ducted containing system Number of space conditioning entirely new 09 Climate Zone 4 10 (SC) systems in this dwelling 1 component? components? feet of ducts? duct system? unit. Alteration Type B. Space Conditioning (SC) System Information 01 02 03 04 05 06 07 08 09 10 Is the SC Installing a SC System SC System CFA served system a refrigerant Installing new SC Installing Installing Installing Identification or Location or Area by this SC ducted containing system more than 40 entirely new entirely new Name Served System (ft2) system? component? components? feet of ducts? duct system? SC system? Alteration Type Furnace Altered space replacement add whole house 1700 Yes Yes Yes No No No conditioning system A/C C. Extension of Existing Duct System, Greater Than 40 Feet (Section 150.2(b)1Diib) This section does not apply to this project. Registration Number: 215-A0181286A-000000000-0000 Registration Date/Time: 2015-07-02 12:52:58 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2014-03-31 Report Generated: 2015-07-02 12:45:18 Schema Version: 0.555SDD CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E Alterations to Space Conditioning Systems (formerly CF -IR -ALT -HVAC) (Page 2 of 3 ) D. Altered Space Conditioning System (Sections 150.2(b)lE and F) O1 02 03 04 05 06 07 08 09 10 11 12 Heating Cooling System Heating Altered Heating Minimum Altered Cooling Minimum Required New or Identification System Heating Efficiency Efficiency Cooling Cooling Efficiency Efficiency Thermostat Replaced New Duct or Name Type Components Type Value System Type Components Type Value Type Duct Length R -Value Furnace Central gas All new Central split All new This field or This field or replacement heating AFUE 0.8 cooling SEER 13 Setback section is not section is not add A/C furnace components AC components applicable applicable Reauired Documentation: CF211-MCH-01-E - Space Conditioning Systems Ducts and Fans -Duct insulation requirement for new plenums: R6. CF2R-MCH-20-H & CF311-MCH-20-H - Duct Leakage testing required when heating or cooling components are installed in ducted systems, or when more than 40 ft of duct length is replaced. -Leakage rate compliance: <_ 15%, or <- 10% leakage to outside, or seal all accessible leaks. CF2R-MCH-25-H & CF3R-MCH-25-H Refrigerant Charge Verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15). CF2RCF3R-MCH-23 & CF3R-MCH-23 Air Flow 2 300 CFM/ton required when MCH -25 is required. Exceotions: -Duct systems registered with HERS provider as previously sealed are exempt from MCH -20 Duct Leakage Testing requirements. -Heating-only systems and Air Handler/Furnace changes do not require verification of Air Flow MCH -23, or Refrigerant Charge MECH-25. -Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH -20 Dud Leakage Testing requirements. E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150.2(b)lDiia and 150.2(b)1E, F) This section does not apply to this project. F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)lC) This section does not apply to this project. Registration Number: 215-A0181286A-000000000-0000 Registration Date/Time: 2015-07-02 12:52:58 HERS Provider: CalCERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2014-03-31 Report Generated: 2015-07-02 12:45:18 Schema Version: 0.555SDD CERTIFICATE OF COMPLIANCE CUR -ALT -02-E Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC) (Page 3 of 3 ) Documentation Author's Declaration Statement 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: �����,� �//�f�� Documentation Author Signature: e� 6 Faulkner, Cindy CI,GC,/�m,& v Company: Signature Date: ATKINSON CLIMATROLLERS INC dba VALLEY HEATING,COOLING & ELECTRICAL 2015-07-02 12:52:58 Address: CEA/ HERS Certification Identification (if applicable): 1171 NORTH 4TH STREET City/State/Zip: Phone: SAN JOSE CA 95112 (408) 294-6290 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency forapproval`with this building permit application. 5. 1 will ensure that a registered copy of this Certificate of Compliance shall be matte available with the building permit(s) issued for the building, and trade available totheenforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Responsible Designer Signature:Q� Faulkner, Cindy Cf/CLCIr/ i Company: Date Signed: ATKINSON CLIMATROLLERS INC dba VALLEY HEATING,COOLING & ELECTRICAL 2015-07-02 12:52:58 Address: License: 1171 NORTH 4TH STREET 258540 City/State/Zip: Phone: SAN JOSE CA 95112 (408) 294-6290 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 215-A0181286A-000000000-0000 Registration Date/Time: 2015-07-02 12:52:58 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2014-03-31 Report Generated: 2015-07-02 12:45:18 Schema Version: 0.555SDD CUPERTINO WATER -CONSERVING PLUMBING FIXTURES OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 _ //`` (4-078) 777-3228 • FAX (408) 777-3333 • building(cDcupertino.org Owner Name L— U �1 1 S Q'd Permit No. -Z -7 U U 1-6 1. Is your real property a registered historical site? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form. Owner' Signature: Date: No Go to Question 2. 2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its plumbing, installation of water -conserving plumbing fixtures is not technically feasible? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. ❑ The licensed plumber's certification has been provided to the Building Division. Sign below and skip the rest of the form. Owner' Signature: Date: , ¢ (20 Ir No Go to Question 3. 3. Is water service permanently disconnected for your building? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form. Owner' Signature: � Date: No Go to Question 4. T 4. Is your real property built and available for use or occupancy on or before January 1, 1994? ❑ No My real property is built and available for use or occupancy after January 1, 1994. Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form. Owner' Signature:Date: (� I 2-C ( S P"Yes My real property is built and available r use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101.8 apply. Refer to the attached. My property is a single-family residential real property. See Civil Code Section 1101.4. On and after January 1, 2014, building alterations or improvements shall require all non-compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non-compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements). ❑ My property is a multifamily residential real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water - conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). ❑ My property is a commercial real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. SB407 2015. doc revised 02104115 On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). I/We, the owner(s) of this property, certify under penalty of perjury that non-compliant plumbing fixtures will be replaced prior to date specified above with water -conserving plumbing fixtures in accordance with Civil Code Sections 110 1. 1 through 1101.8, the current California Plumbing Code and California Green Building Standards Code, and manufacturer's installation requirements, and that the water -conserving pl bing fixtures comply with the requirements as indicated in the table below. Owner's (or Owner Agent's) Signature: Date: mol Upon completing and signing this Certificate, please return it to the Building Division in order to final your pen -nit. 1. If the existing plumbing fixture water usage/flow rate is equal to or lower than the figure shown, it is not required to be upgraded. SB407 2015. doe revised 02/04/15 Non -Compliant Water -Conserving Plumbing Fixture PlumbingFixture (Fixture Complying with Current Code Applicable to New Construction) Maximum Water Usage/Flow Rate Fixture Type Water Usage 2013 CPC Ch. 4 2013 CPC Ch. 4 2013 CPC Ch. 4 /Flow Rate 2013 CALGreen Div. 4.3 2013 CALGreen Div. 4.3 2013 CALGreen Div. 5.3 Single -Family Multi -Family Commercial Residential Residential Water Closets Exceed 1.6 Single flush toilets: 1.28 gallons/flush (Toilets) Gallons/flush Dual flush toilets: 1.28 gallons/flush effective flush volume (the composite, average flush volume of two reduced flushes and one full flush Urinals Exceed 1.0 0.5 gallons/flush Gallons/flush Showerheads Exceed 2.5 2.0 gallons per minute @ 80 psi. Also certified to the performance criteria of gallons per minute U.S. EPA WaterSense Specification for Showerheads (A hand-held shower is considered a showerhead.) For multiple showerheads serving one shower, the combined flow rate of all showerheads and/or other shower outlets controlled by a single valve shall not exceed 2.0 gallons per minute @ 80 psi, or the shower shall be designed to allow only one shower outlet to be in operation at a time. Faucets — Exceed 2.2 gallons Maximum 1.5 gallons per Within units: 0.5 gallons per minute @ 60 Lavatory per minute minute @ 60 psi; minimum Maximum 1.5 gallons psi Faucets 0.8 gallons per minute @ per minute @ 60 psi; 20 psi minimum 0.8 gallons per minute @ 20 psi In common and public use areas: 0.5 gallons per minute @ 60 psi 1.8 gallons per minute 60 psi Faucets — Exceed 2.2 gallons 1.8 gallons per minute @ 1.8 gallons per minute 1.8 gallons per minute @ 60 Kitchen per minute 60 psi @ 60 psi psi Faucets May temporarily increase May temporarily up to 2.2 gallons per increase up to 2.2 minute @ 60 psi, and must gallons per minute @ default to maximum 60 psi, and must 1.8 gallons per minute @ default to maximum 60 psi 1.8 gallons per minute Where faucets meeting @ 60 psi the above are unavailable, Where faucets meeting aerators or other means the above are may be used to achieve unavailable, aerators or reduction. other means may be used to achieve reduction. 1. If the existing plumbing fixture water usage/flow rate is equal to or lower than the figure shown, it is not required to be upgraded. SB407 2015. doe revised 02/04/15 CALIFORNIA CIVIL CODE SECTIONS 1101.1-1101.8 Civil Code Division 2. Property Part 4. Acquisition of Property Title 4. Transfer Chapter 2. Transfer of Real Property Article 1.4. Installation of Water Use Efficiency Improvements ........ 1101.1 — 1101.8 1101.1. The Legislature finds and declares all of the following: (a) Adequate water supply reliability for all uses is essential to the future economic and environmental health, of California. (b) Environmentally sound strategies to meet future water supply and was treatment needs are key to protecting and re storing -aquatic resources in. California. -(c) There is a pressing need to address water supply -reliability issues raised by growing urban areas. (d) Economic analysis by urban water agencies has identified urban water conservation as acost-effective- approach to -addressing water supply needs. (e) There are many water conservation practices that produce significant energy and other resource savings that should be encouraged as a matter of state policy. (f) Since the 1991 signing of the "Memorandum of Understanding Regarding Urban Water Conservation in California," many urban water and wastewater treatment agencies have gained valuable experience that can be applied to produce significant statewide savings of water, energy, and associated infrastructure costs. This experience indicates a need to regularly revise and update water conservation methodologies and practices. (g) To address these concerns, it is the intent of the Legislature to require that residential and commercial real property built and available for use or occupancy on or before January 1, 1994, be equipped with water -conserving plumbing fixtures. (h) It is further the intent of the Legislature that retail water suppliers are encouraged to provide incentives, financing mechanisms, and funding to assist property owners with these retrofit obligations. 1101.2. Except as provided in Section 1101.7, this article shall apply to residential and commercial real property built and available for use on or before January 1, 1994. 1101.3. For the purposes of this article: (a) "Commercial real property" means any real property that is improved with, or consisting of, a building that is intended for commercial use, including hotels and motels, that is not a single-family residential real property or a multifamily residential real property. (b) "Multifamily residential real properly" means any real property that is improved with, or consisting of, a building containing more than one unit that is intended for human habitation, or any mixed residential -commercial buildings or portions thereof that are intended for human habitation. Multifamily residential real property includes residential hotels but does not include hotels and motels that are not residential hotels. (c) "Noncompliant plumbing fixture" means any of the following: (1) Any toilet manufactured to use more than 1.6 gallons of water per flush. (2) Any urinal manufactured to use more than one gallon of water per flush. (3) Any showerhead manufactured to have a flow capacity of more than 2.5 gallons of water per minute. (4) Any interior faucet that emits more than 2.2 gallons of water per minute. (d) "Single-family residential real property" means any real property that is improved with, or consisting of, a building containing not more than one unit that is intended for human habitation. (e) "Water -conserving plumbing fixture" means any fixture that is in compliance with current building standards applicable to a newly constructed real property of the same type. (f) "Sale or transfer" means the sale or transfer of an entire real property estate or the fee interest in that real property estate and does not include the sale or transfer of a partial interest, including a leasehold. 1101.4. (a) On and after January 1, 2014, for all building alterations or improvements to single-family residential real property, as a condition for issuance of a certificate of final completion and occupancy or final permit approval by the local building department, the permit applicant shall replace all noncompliant plumbing fixtures with water - conserving plumbing fixtures. (b) On or before January 1, 2017, noncompliant plumbing fixtures in any single-family residential real property shall be replaced by the property owner with water -conserving plumbing fixtures. (c) On and after January 1, 2017, a seller or transferor of single-family residential real property shall disclose in writing to the prospective purchaser or transferee the requirements of subdivision (b) and whether the real property includes any noncompliant plumbing fixtures. " 1101.5. (a) On or before January 1, 2019, all noncompliant plumbing fixtures in any multifamily residential real property and in any commercial real property shall be replaced with water -conserving plumbing fixtures. (b) An owner or the owner's agent may enter the owner's property for the purpose of installing, repairing, testing, and maintaining water -conserving plumbing fixtures required by this section, consistent with notice requirements of Section 1954. (c) On and after January 1, 2019; the water -conserving plumbing fixtures required by this section shall. be operating at the manufacturer's rated water consumption at the time that the tenant takes possession. A tcnant shall be responsible for notifying the owner or owner's agent if the tenant becomes aware that a water -conserving p � g g g...__-__ ._ . plumbing: fixture within his or her unit is not operating iat. the manufacturer's rated water consumption: -The owner or owner's agent shall correct an inoperability in a water -conserving plumbing fixture upon notice by the tenant, or if detected by the owner or the owner's agent. (d) (1) On and after January 1, 2014, all noncompliant plumbing fixtures in any multifamily residential real property and any commercial real property shall be replaced with water -conserving plumbing fixtures in the following circumstances: (A) For building additions in which the sum of concurrent building permits by the same permit applicant would increase the floor area of the space in a building by more than 10 percent, the building permit applicant shall replace all noncompliant plumbing fixtures in the building. (B) For building alterations or improvements in which the total construction cost estimated in the building permit is greater than one hundred fifty thousand dollars ($150,000), the building permit applicant shall replace all noncompliant plumbing fixtures that service the specific area of the improvement. (C) Notwithstanding subparagraph (A) or (B), for any alterations or improvements to a room in a building that require a building permit and that room contains any noncompliant plumbing fixtures, the building permit applicant shall replace all noncompliant plumbing fixtures in that room. (2) Replacement of all noncompliant plumbing fixtures with water -conserving plumbing fixtures, as described in paragraph (1), shall be a condition for issuance of a certificate of final completion and occupancy or final permit approval by the local building department. (e) On and after January 1, 2019, a seller or transferor of multifamily residential real property or of commercial real property shall disclose to the prospective purchaser or transferee, in writing, the requirements of subdivision (a) and whether the property includes any noncompliant plumbing fixtures. This disclosure may be included in other transactional documents. 1101.6. The duty of an owner or building permit applicant to comply with the requirements of this article shall be postponed for one year from the date of issuance of a demolition permit for the building. If the building is demolished within the one-year postponement, the requirements of this article shall not apply. If the building is not demolished after the expiration of one year, the provisions of this article shall apply, subject to appeal to the local building department, even though the demolition permit is still in effect or a new demolition permit has been issued. 1101.7. This article shall not apply to any of the following: (a) Registered historical sites. (b) Real property for which a licensed plumber certifies that, due to the age or configuration of the property or its plumbing, installation of water -conserving plumbing fixtures is not technically feasible. (c) A building for which water service is permanently disconnected. 1101.8. A city, county, or city and county, or a retail water supplier may do either of the following: (a) Enact local ordinances or establish policies that promote compliance with this article. (b) Enact local ordinances or establish policies that will result in a greater amount of water savings than those provided for in this article. P. CUPERTINO SMOKE / CARBON MONOXIDE ALARMS OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building(5)cupertino.org Permit No. 1,n7 00&6 Address ���� ��� �b�� �(�?)2��tt2� 4ofAlarms Smoke: ! Carbon Monoxide: I _ ter_ - - 1'ER'111T CA_N'N'0T BE El`�'AIAA) AND C() 01PL ETEI) I'N"I 111,1111S CEW11FRIATE, I 1S f3F1 7� SIGN 1.) A N1) 1:T 1 URLl r) F 0%4!J IV 11AL-DING I)1V IS10N PURPOSE This affidavit is a self -certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R314, 2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single-family and multi -family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds $1000.00, CRC Section R314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations: AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of the bedroom(s) X X On every level of a dwelling unit including basements X X Within each sleeping room X Carbon Monoxide alarms are not required in dwellings which do not contain fuel -burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. Power Supply: In dwelling units with no commercial power supply, alarm(s) may be solely battery operated. In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl space. Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2. An electrical permit is required for alarms which must be connected to the building wiring. As owner of the above -referenced property, I hereby certify that the alarm(s) referenced above has/have been installed in accordance with the manufacturer's instructions and in compliance with the California Building and California Residential Codes. The alarms have been tested and are operational, as of the date signed below. I have read and agree to comply with the terms and conditions of this statement Owner V (or Owner Agent's) Name: L. of _7 C, ,/ Signature .... ............................ ...................................:........................................... Date: aI.`.t.tfI Contractor Name: Signature...................................................................Lic.#...................................... Date:................... Smoke and CO form.doc revised 03118114