Loading...
15040189-Backfill Testing❑ J, 11 Material Testing results for Pool Backfill Testing at 10973 Wilkinson Ave. Campbell, CA Prepared for NOECON LM Yale Bertolucci, CQE Construction Quality Enterprises P.O. Box 627, Lakeport, California 95453 Report Date May 19, 2015 r3� i Yale Bertolucci, COE Construction Quality Enterprises P.O. Box 627, Lakeport, California 95453 May 19, 2015 Noe Gonzalez NOECON P.O. Box 317 Alviso, California 95002 RE: Pool Backfill Testing, 10973 Wilkinson Ave., Campbell, CA Dear Mr. Gonzalez, Enclosed you will find for your review the report on the max density/opt moisture determination and density test results, along with the invoice for the Pool Backfill Testing, 10973 Wilkinson Ave., Campbell, CA Please call me if you have any questions, wish to go over the data or require additional services.. I want to thank you for allowing us the opportunity of providing our services on your project. We appreciate your business and hope we have provided you with service that meet or exceeded your expectations. Respectfully Submitted, Yale Bertolucci Owner/Senior Consultant Toll Free: 877-813-9181 Fax: 866-685-5488 Yale Bertolucci, CQE Construction Quality Enterprises Client: NOECON Date: May 19, 2015 Project: Pool Backfill Testing Project No.: CQE 072-008 Project Location: 10973 Wilkinson Ave., Campbell, CA Maximum Density/Optimum Moisture Determination Sample Material Description Max Dry Density Optimum Moisture #1 Dark Reddish Brown Sandy Silty Clay W/Some Fine Gravel 122.0 13.3 #2 Dark Brown Sandy Silty Clay W/Fine to Coarse Gravel 122.6 11.7 #3 Brown Sandy Silty Clay W/Some Fine Gravel 117.1 12.9 Testing performed in accordance with ASTM D 1557-07 B Yale Bertolucci Owner/Senior Consultant Yale Bertolucci, CQE Construction Quality Enterprises Client: NOECON Date: May 19, 2015 Project: Pool Backfill Testing Project No.: CQE 072-008 Project Location: 10973 Wilkinson Ave. Campbell, CA Density Determination Testing performed in accordance with ASTM D6938 V4&4 0 0,0001, U Yale Bertolucci Owner/Senior Consultant 0 Percent Comp. Curve 92 #1 98 #1 91 #3 92 #3 94 #2 93 #2 92 #2 97 #2 Test Moist. Dry Test Date Elev. Test Location Cont. Dens. 2015 #1 5/13 -6.0' 9'S & 21'W of N W Corner of House 18.8 111.9 #2 5/13 -5.0' 6'S & 24'W of N W Corner of House 14.0 120.3 #3 5/14 -4.0' 21'S & 21'W of N W Corner of House 19.3 106.2 #4 5/14 -3.0' 6'S & 24'W of N W Corner of House 19.7 107.3 #5 5/15 -2.0' 21' S & 24'W of N W Corner of House 17.0 114.7 #6 5/15 -2.0' 6'S & 18'W of N W Corner of House 16.9 113.4 #7 5/15 -1.0' 10'S & 18'W of N W Corner of House 16.8 111.9 #8 5/15 -1.0' 24'S & 15'W of N W Corner of House 15.2 119.1 Testing performed in accordance with ASTM D6938 V4&4 0 0,0001, U Yale Bertolucci Owner/Senior Consultant 0 Percent Comp. Curve 92 #1 98 #1 91 #3 92 #3 94 #2 93 #2 92 #2 97 #2 /3'), POOL DEMOLITION RECOMMENDATIONS / S 0 Y01g� PROPOSED POOL DEMOLITION 10973 WILKINSON AVENUE CUPERTINO, CALIFORNIA Prepared for: NOECON Prepared by: GeoEngineering Consultants April 2015 �R inee f ­70nsu�ta GeoEngineering Consultants (GEC) -4125 Blackford Avenue, -Suite 145 San Jose, CA 95117 Phone: 925-321-5550 Project No... P15.0159 April 28, 2015 . Noe Gonzalez NOECOlV Subject: Proposed Pool Demolition 10973 Wilkinson Ave. Cupertino, Ca Pool Demolition and Backfill Recommendations Dear Noe: In accordance with .your: authorization,. GeoEngineering Consultants (GE(7) is providing this pool demolition and backfill recommendation for the subject site. ----- The. accompanying recommendation letter presents our findings and conclusions based on our site visit. Our findings indicate that, from a geotechnical point of view, the proposed demolition and backfill is feasible at the subject site provided the recommendations of this report are carefully followed. and :are incorporated into the project plans: Should you :have any questions_ relating to the contents of this letter report or should you require additional information; please do not hesitate to contact our office at your convenience. �� F .. Sincerely yours, GEC. No. G 66379 No. GE 2796 Exp. 6-30-20W 11 cM;-KZ h �� Kamran G 'assi, Ph.D., G. Principal Geotechnical Engineer Contents 1: 'INTRODUCTION...:............................:.................. 4: ...........:...:.......................:... I.I. Purpose and Scope......................................:............................................................4 1.2. Project Description............ ........... :................................................ .. ................. 5. 2. FINDINGS.................:...................................................................................:................5 2.1. Site Description .......... ...........:..::::.............. ................................. ................5 3. RECOMMENDATIONS .................... .... ...............5 ......................................................... ... 3.1. General ......... ................. ..................................................................... ....:......... .5 3.2. Demolition ........................ 3.3. Backfill.....................:..:......................:::................................................ ..... ..6 APPENDIXA....................................:......................................................................................7 THE GRADING'SPECIFICATIONS.:::.:.................::...::..:....................::.....,:.........................::...:........8 GUIDE SPECIFICATIONS FOR ROCK UNDERFLOOR SLABS ................................................................ ...................................:.....................13 P15.0159 10973 Wilkinson Ave., Cupertino; Ca Apr. 28, 2015 1. INTRODUCTION This -report summarizes our findings and :conclusions for use in consideration of :proposed pool demolition:arid backfill at the above -referenced address, based on our site visit and review of the City of Cupertino Guideline for Swimming: Pool Demolition. 1.1. Purpose and Scope The purpose, of the work was to provide pool demolition and backfill recommendations at the site located in Cupertino, California. Our scope of service included the following:: a. Field reconnaissance by the Soil Engineer; q. b. Preparation of this written: report. This report has been prepared as a product of our service for the exclusive use of NOECON for the. proposed pool demolition and backfill at the subject property. This report must not be used by other parties or for other purposes without prior written authorization from GEC. No other warranty, either expressed or implied,. is made. Because of possible future changes in site conditions or the 'standards of practice for geotechnical engineering, the findings and recommendations of this report may not be considered valid beyond two years from the report. date, without review by GEC. In, addition, in the event- that any changes in the nature or location of the proposed improvements are: planned, the conclusions and recommendations of this report may not be considered valid unless such changes are reviewed, and the conclusions and recommendations presented in this report are modified or verified in writing, by this firm. GEC Page 4 P15.0159 10973 Wilkinson Ave., Cupertino; Ca Apr. 28, 2015 - 1.2.. Proiect Description Based on our discussions with you, we understood that the existing pool will be completely demolished and will be backfilled. The existing -pool is up to. 6 feet deep and is roughly hour -glass shape with: side length of about 35 feet. The minimum distance to the existing house footprint is about 10 feet. It is, assumed that: the area to be backfilled will not be used fora future building: pad or structure. This report is not a Geotechnical Engineering Study. This -report should not be used for future development iii the area of the proposed pool. backfill: 2. FINDINGS - 2.1. Site Description The roughly rectangular -shaped parcel -is located on a flat: site at 10973 Wilkinson Avenue : in Cupertino and is one parcel. The site is bounded by Wilkinson Avenue to the east and Columbus Avenue to the south and: other residences to the other directions. There is an existing two-story wooden=frame _ house with an attached garage at the .site. The backyard: area has been landscaped. Wooden fences separate the residence from the adjacent neighbors. 3: RECOMMENDATIONS 3,1. General . From a geotechnical point of view, the proposed. pool demolition and backfill is feasible at the subject site provided the recommendations presented in this letter are incorporated into the project plans. 3.2. Demolition The Contractor should remove the entire pool structure. All the decking and swimming pool equipments,:pool structure bond beam, electric conduit, and gas lines should be removed. GEC... Page 5 PB.0159 10973 Wilkinson Ave., Cupertino; Ca Apr. 28, 2015 3.3. Backfill The grading requirements presented herein are an integral part of the grading specifications presented in Appendix A of this report and should be considered as such. Grading activities during the rainy season will be hampered by excessive moisture. Grading activities may be performed during the rainy season, however, achieving proper compaction :may be difficult due to excessive moisture; and delays may occur. After demolition, the site may be brought to the desired finished .grades -by placing. engineered fill in lifts not to exceed 8 inches in uncompacted thickness and compacted to a minimum relative compaction of 90% at a moisture content of 2 to 5 percent above optimum as determined by ASTM D 1557-91 Laboratory Test. Procedure. . Should general import material be used to establish the proper grading for the proposed development, the import material should be approved by the Soil Engineer before it is brought to the site. General import material should preferably have. an expansion potential similar to or less than the on site native soil. Selection of the import material is essential on rate of progress of the project. The following criteria are suggested a. Have an R -Value of not less than 25; b. Have a Plasticity Index not higher than 16 (see Foundation section); C. Not more than 15% passing: the No. 200 sieve; . d. No rocks larger than 6 inches 'in maximum size; GEC Page 6 APPENDIX A The Grading Specifications Guide Specifications for Rock Under Floor Slabs THE GRADING SPECIFICATIONS On 224332 CARNOUSTIE CT. CUPERTINO, CALIFORNIA 1. General Description 1.1 These specifications have been prepared for the grading and site development of the subject parking lot development. GEC, hereinafter described as the Soil Engineer, should be consulted prior to any site work connected with site development to ensure compliance with these specifications. 1.2 The Soil Engineer should be notified at least two working days prior to any site clearing or grading operations on the property in order to observe the stripping of organically contaminated material and to coordinate the work with the grading contractor in the field. 1.3 This item shall consist of all clearing or grubbing, preparation of land to be filled, filling of the land, spreading, compaction and control of fill, and all subsidiary work necessary to complete the grading of the filled areas to conform with the lines, grades, and slopes as shown on the accepted plans. The Soil Engineer is not responsible for determining line, grade elevations, or slope gradients. The property owner, or his representative, shall designate the person or organizations who will be responsible for these items of work. 1.4 The contents of these specifications shall be integrated with the soil report of which they are a part, therefore, they shall not be used as a self-contained document. 2. Tests The standard test used to define maximum densities of all compaction work shall be the ASTM D1557-91 Laboratory Test Procedure. All densities shall be expressed as a relative compaction in terms of the maximum dry density obtained in the laboratory by the foregoing standard procedure. 3. Clearing, Grubbing, and Preparing Areas To Be Filled 3.1 If encountered, all vegetable matter, trees, root systems, shrubs, debris, and organic topsoil shall be removed from all structural areas and areas to receive fill. 3.2 If encountered, any soil deemed soft or unsuitable by the Soil Engineer shall be removed. Any existing debris or excessively wet soils shall be excavated and removed as required by the Soil Engineer during grading. 3.3 All underground structures shall be removed from the site such as old foundations, abandoned pipe lines, septic tanks, and leach fields. 3.4 The final stripped excavation shall be approved by the Soil Engineer during construction and before further grading is started. 3.5 After the site has been cleared, stripped, excavated to the surface designated to receive fill, and scarified, it shall be bladed until it is uniform and free from large clods. The native subgrade soils shall be moisture conditioned and compacted to the requirements as specified in the grading section of this report. Fill can then be placed to provide the desired finished grades. The contractor shall obtain the Soil Engineer's approval of subgrade compaction before any fill is placed. 4. Materials 4.1 All fill material shall be approved by the Soil Engineer. The material shall be a soil or soil - rock mixture which is free from organic matter or other deleterious substances. The fill material shall not contain rocks or lumps over 6 inches in greatest dimension and not more than 15% larger than 2-1/2 inches. Materials from the site below the stripping depth are suitable for use in fills provided the above requirements are met. 4.2 Materials existing on the site are suitable for use as compacted engineered fill after the removal of all debris and organic material. All fill soils shall be approved by the Soil Engineer in the field. 4.3 Should import material be required, it must meet the specifications as delineated in the body of this report. 5. Placine. Spreading, and Compacting Fill Material 5.1 - The fill materials shall be placed in uniform lifts of not more than 8 inches in uncompacted thickness. Each layer shall be spread evenly and shall be thoroughly blade mixed during the spreading to obtain uniformity of material in each layer. Before compaction begins, the fill shall be brought to a water content that will permit proper compaction by either (a) aerating the material if it is too wet, or (b) spraying the material with water if it is too dry. 5.2 After each layer has been placed, mixed, and spread evenly, either import material or native material shall be compacted to a relative compaction designated for engineered fill. 5.3 Compaction shall be by footed rollers or other types of acceptable compacting rollers. Rollers shall be of such design that they will be able to compact the fill to the specified density. Rolling shall be accomplished while the fill material is within the specified moisture content range. Rolling of each layer shall be continuous over its entire area and the roller shall make sufficient trips to ensure that the required density has been obtained. No ponding or jetting shall be permitted. 5.4 Field density tests shall be made in each compacted layer by the Soil Engineer in accordance with Laboratory Test Procedure ASTM D1556-64 or D2922-71. When footed rollers are used for compaction, the density tests shall be taken in the compacted material below the surface disturbed by the roller. When these tests indicate that the compaction requirements on any layer of fill, or portion thereof, have not been met, the particular layer, or portion thereof, shall be reworked until the compaction requirements have been met. 5.5 No soil shall be placed or compacted during periods of rain nor on ground which contains free water. Soil which has been soaked and wetted by rain or any other cause shall not be compacted until completely drained and until the moisture content is within the limits hereinbefore described or approved by the Soil Engineer. Approval by the Soil Engineer shall be obtained prior to continuing the grading operations. 6. Utility Trench Backfill 6.1 The utility trenches extending under concrete slabs -on -grade shall be backfilled with native on-site soils or approved import materials and compacted to the requirements pertaining to the adjacent soil. No ponding or jetting will be permitted. 6.2 Utility trenches extending under all pavement areas shall be backfilled with native or approved import material and properly compacted to meet the requirements set forth by the City of Cupertino. 6.3 Where any opening is made under or through the perimeter foundations for such items as utility lines and trenches, the openings must be resealed so that they are watertight to prevent the possible entrance of outside irrigation or rain water into the underneath portion of the structures. 7. Unusual Conditions 7.1 In the event that any unusual conditions not covered by the special provisions are encountered during the grading operations, the Soil Engineer shall be immediately notified for additional recommendations. 8. General Requirements Dust Control 8.1 The contractor shall conduct all grading operations in such a manner as to preclude windblown dirt and dust and related damage to neighboring properties. The means of dust control shall be left to the discretion of the contractor and he shall assume liability for claims related to windblown material. t GUIDE SPECIFICATIONS FOR ROCK UNDER FLOOR SLABS Definition Graded gravel or crushed rock for use under slabs -on -grade shall consist of a minimum thickness of mineral aggregate placed in accordance with these specifications and in conformance with the dimensions shown on the plans. The minimum thickness is specified in the accompanying report. Material The mineral aggregate shall consist of broken stone, crushed or uncrushed gravel, quarry waste, or a combination thereof. The aggregate shall be free from deleterious substances. It shall be of such quality that the absorption of water in a saturated dry condition does not exceed 3% of the oven dry weight of the sample. Gradation The mineral aggregate shall be of such size that the percentage composition by dry weight, as determined by laboratory sieves (U.S. Sieves) will conform to the following gradation: Sieve Size Percentage Passing 3/4" 90-100 No. 4 25-40 No. 8 18-33 No. 200 0-3 Placing Subgrade, upon which gravel or crushed rock is to be placed, shall be prepared as outlined in the accompanying soil