Loading...
15050104I CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 22460 STARLING CT I CONTRACTOR: PETERSEN -DEAN INC I PERMIT NO: 15050104 1 OWNER'S NAME: JONATHAN G BORNSTEIN &PHYLLIS BROCK 17980 ENTERPRISE DR I DATE ISSUED: 05/18/2015 1 OWNER'S PHONE: 4084062671 1 NEWARK, CA 94560 1 PHONE NO: (510)194 -9982 1 ❑ LICENSED CONTRACTOR'S DECLARATION License Class ° 6- "d "� Lic. #� f Contractor �401 -'eeLl ) a at. Date I L4 I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self- insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION 1 certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source re lations per the Cupertino Municipal Code, Section 9.18.E M Si g Date, �. nature -,� ❑ OWNER- BUILDER DECLARATION I hereby affirm that 1 am exempt from the Contractor's License Law for one of the following two reasons: I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.7044, Business & Professions Code). I hereby affirm under penalty of perjury one of the following three declarations: I have and will maintain a Certificate of Consent to self - insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. APPLICANT CERTIFICATION I certify that 1 have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Date JOB DESCRIPTION: RESIDENTIAL ❑ COMMERCIAL INSTALLATION OF ROOF MOUNTED SOLAR (18 MODULES)(4.95 KW) Sq. Ft Floor Area: I Valuation: $23100 I APN Number: 32613025.00 1 Occupancy Type: PERMIT EXPIRES IF WORK IS NOT STARTED WITHIN 180 DAYS OF PERMIT ISSUANCE OR 180 DAYS FROM LAST CALLED INSPECTION. Issued by }. �� Date: s RE- ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, 1 agree to remove all new materials for inspection. Signature of Applicant: Date: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER HAZARDOUS MATERIALS DISCLOSURE I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. 1 will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I will maintain compliance with the Cuper ' unicipal Code, Chapter 9.12 and the Health uthorized agent: 2$50,15-,2553 Y 5534. Owner or ,r Date: CONSTRUCTION LENDING AGENCY 1 hereby affirm that there is a construction lending agency for the performance of work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name Lender's Address ARCHITECT'S DECLARATION I understand my plans shall be used as public records. Licensed Professiona CUPERTINO ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building acupertino. org 'Y AE PROJECT ADDRESS APN 9 OWNERNAME "go PHONE E-MAIL 0 STREET ADDRESS 21-7 CITY, STATE, zip FAX 75'C CONTACT CONTACT NAME T,, PHONE ry zs- E-MAIL -24? STREET ADDRESS '7 CITY STATE, ZIP FAX 4, ❑ OWNER ❑ OWNER-BUILDER ❑ OWNER AGENT QfCOMRACTOR QroNTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME LICENSE NUMBER» LICENSETYPE BUS LIC COMPANY NAME E-MAIL FAX STREET ADDRESS C1 ? C) CITY STATE, ZIP PHONE �/'� -Z-(,- ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS. LIC fl COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE USE OF �SFD or Duplex ❑ Multi-Family PROJECT IN WILDLAND PROJECT IN STRUCTURE: ❑ Commercial URBAN INTERFACE AREA ❑ Yes "'r"No T_ FLOOD ZONE ❑ Yes No 1% ' 40LAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PANELS: NUMBER OF PAN ELS/UNITS: KILOWATTS (COMMERCIAL ONLY): TOTAL VALUATION: Z DESCRIPTION OF WORK J,�jj f-' c r) JA 4. By my signature below, I certify to each of the follo 'ng: I am the property ovite"ror authorized age n —property eaif. I have read this application and the information I have provided ve read the Description of Work and verify it is accurate. I agree to comply with all applicable local Wa. authorize representatives ofCupertino to enter the abov property for inspection purposes. to ui i Zec� �t r ordinances and state laws relating b ld'nae6_ : i� . I 'pideatified Signature of Applicant/Agent: Date: ';1" SUPPLEMENTAL INFORMATION REQUIRED `2 0 go 'g/ NSIZ 0/' "'w �g 1/ag &gpg g', 6/ PVApp.2011.doc revised 03116111 FM-7 CITY OF CUPERTINO FEE ESTIMATOR - BUILDING DIVISION NOTE: This estimate does not include fees due to other Departments (Le. Planning, Public Works, Fire, Sanitary Sewer District, School MctrirL atr ) Thavo faer are hncad an the nreliminary information avadahle and are anly an owimaty_ Cantart the Dent fnr addn'I info_ FEE ITEMS (Fee Resolution 11 -053 E.tf' 711113) ADDRESS: 22460 STARLING CT DATE: 05/18/2015 REVIEWED BY: MELISSA MISC ITEMS APN: BP #: �Sol "VALUATION: 1$23,100 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY SFD or Duplex Alternative Energy System IPHOTOV) ES Photovoltaic System PENTAMATION SOLAR -RE USE: F0.0 I PERMIT TYPE: i WORK INSTALLATION OF ROOF MOUNTED SOLAR 18 MODULES 4.95 k SCOPE $0.00 NOTE: This estimate does not include fees due to other Departments (Le. Planning, Public Works, Fire, Sanitary Sewer District, School MctrirL atr ) Thavo faer are hncad an the nreliminary information avadahle and are anly an owimaty_ Cantart the Dent fnr addn'I info_ FEE ITEMS (Fee Resolution 11 -053 E.tf' 711113) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 1 # $236.00 Alternative Energy System IPHOTOV) ES Photovoltaic System Suppl. PC Fee: Q Reg. Q OT F0.0 I hrs $0.00 PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Fee:Q Reg. Q OT I-0-.0-1 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 ,1r {ar�iNri�lo °r iii � d'E'rr: 0 0 Work Without Permit? 0 Yes 0 No $0.00 Advanced Planning, Fee: $0.00 Select a Non - Residential Building or Structure 0 0 i lr<+. Ila 'e�G.crr�rrz�rxtr ° <,nrG�R ^,: Strong Motion Fee: IBSEISMIC2 $3.00 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $1.00 SUBTOTALS: $4.00 $236.00 T{)TA, SEE. ' $240.00 Revised: 0510712015 a = TUV Power controlled: 'ruvanAmh�a Lowest measuring tolerance in industry 00000° Every component is tested to meet 3 times IEC requirements J Designed to withstand heavy accumulations of snow and ice J Sunmodule Plus: Positive performance tolerance 'J j 25 yearariin7pterfo ` ante warran t" and 10 �r warranty rayo J CId�Rf DOPerb7mm, I I� 'A k 9 1 mat .1 F,l �y 1 1,13 PP 'q Glass with anti re e Iver;' 0jj1Jftj w� �� World-class quality �/ . . „s 10uP ky tl IEC 61]SA ,� ,(y wrA Fully- automated production lines and seamless monitoring of the process and mate- 3b p 'rx1 ^m'istx S P rCa IIUE rial ensure the quality that the company sets as its bench markfor its sites worldwide. SolarWorld Plus - Sorting Plus Sorting guarantees highest system efficiency. SolarWorld only delivers modules ' us that have greater than or equal to the nameplate rated power. UL 1703 25 -year linear performance guarantee and extension of product warranty to 10 years /” r a C9 SolarWorld guarantees a maximum performance digression of 0.7% p.a. in the course ` of 25 years, a significant added value compared to the two -phase warranties com- mon in the industry. In addition, SolarWorld is offering a product warranty, which has been extended to 10 years.* 'in accordance with the applicable SolarWorld Limited Warranty at purchase. www.solarworld.com /warranty OFFICE N solarworld.com ILPORTED PARTS SSOLARWORLD' SW 275 MONO BLACK REALVALUE PERFORMANCE UNDER STANDARD TEST CONDITIONS (STC)" PERFORMANCE AT 800 W /M2, NOCT, AM 1.5 Maximumpower pm„ 275 W Maximum power Rm„ 203.1Wp Open circuit voltage V. 39.4 V Open circuit voltage V, 3S.7 V Maximum power point voltage V,,,F, 31.0 V Maximum power point voltage V,,,pp 28.1 V Short circuit current 1,, 938 A Short circuit current 1u 73S A Maximum power point current mR, 8.94 A Maximum power point current p 7.22 A Module efficiency rlm 1610 % Minor reduction In efficiency under partial load conditions at 25 °G at 200 W /mi, 100% ( +1-2 %) of the STC efficiency (1000 Wlm2) is achieved. 'STC: 1000 W /mr, 25 °C, AM 1.5 1) Measuring tolerance (P,,) traceable to TUV Rheinland: + /- 2 %(TUV Power Controlled) COMPONENT MATERIALS THERMAL CHARACTERISTICS Cells per module 60 Cell type Mono crystalline NOCT 48 °C Cell dimensions 6.14 in x 6.14 in (1S6 mm x 156 mm) TC 1, 0.044 % / °C Front Tempered glass (EN 12150) TC �a� -0.31 % / °C Frame Black anodized aluminum TCPmPP -0.43 % / °C Weight 39.5 Ibs (17.9 kg) Operating temperature -40 °C to 85 °C SYSTEM INTEGRATION PARAMETERS Maximum system voltage SC 11 /NEC 1000 V Maximum reverse current 16 A 800 W /m2 Number of bypass diodes 3 _ _.. .,_... _ ._.__.____..._....,....- ._____. _. ...__._..__..._,_...____._...._ _ _....._ a Design Loads' 113 psf downward Two rail system 600 W /m� 64 sf upward P P Design Loads' Three rail system 170 psfdownward 400 W /m' i psf upward ._.-.._..._ Design Loads' Edge mounting 30 psf downward - - - -. ___ ..._.._...._._._.._.._-.._._._. _� 200 W /mr 30 psf upward 100W /m' ' Please refer to the Su n module installation Instructions for the details associated with { these load cases. ..r._.._._...,,..,,.._.._. ��._....._..... r._,...__.. r_.._..._. q_,_..__.., Y..... _ ........... _.-...........r_ V. ADDITIONAL DATA Module voltage[ V) Power sorting -0 WP / +S WP x4 37.4-4 (951) J -Box IP65 — Module leads PV wire per UL4703 with H4 connectors Module type (UL 1703) 1 n i-i 11.33 (288) Glass Low iron tempered with ARC 65.94 Version 2.5 frame bottom mounting holes 6 x4 4.20 (107)1 1.22(31) -_ All units provided are imperial. 51 units provided in parentheses. SolarWorld AG reserves the right to make specification changeswithout notice. VERSION 2.5 FRAME Compatible with both "Top- Down" and "Bottom" mounting methods 46rounding Locations: 4 corners of the frame 4locations alongthe length ofthe module in the extended flanget S W- 01- 6025US 08 -2014 SunmodulO/o User Instructions 07/2012 Sunmodule Plus SW xxx poly Sunmodule Plus SW xxx mono (black) Jbiiii SOLAR WORLD www.solarworld - usa.com We turn sunlight into power. DANGER! ©Electric shock The connection of two or more modules in series results in the accumulation of voltage and imposes danger. Do not insert electrically conductive parts into con- nectors! Do not attach solar modules and wiring with wet connectorsl Make sure to work with dry tools and under dry working condilionsl &Work on live parts When working on wiring, use and wear protective equipment (insulated tools, insulated gloves, etc.)I WARNINGI ©Arcing Modules generate direct current (DC) when exposed to light. When breaking a closed circuit, a dangerous arc may be generated. Do not cut any live wires. &Safe installation Do not carry out installation work in strong winds. Secure yourself and other per- sons against falling. Secure work materials against dropping. Ensure a safe working environment so as to prevent accidents. &Fire protection /explosion protection Modules must not be installed in the vicinity of highly flammable gases, vapors or dusts (e.g. filling stations, gas tanks, paint spraying equipment). The safety instruc- tions for other system components must also be followed. Make sure to comply with local standards, building regulations and accident prevention regulations during installation. For roof installation- modules must be mounted on a fire -resi- stant base material. ATTENTION Do not use damaged modules. Do not dismantle modules Do not remove any parts or nameplates fitted by the manufacturer. Do not apply paint or adhesives to the module, nor work on it with sharp objects. Unpacking and intermediate storage Do not use thejunction box as a handle. Do not place modules roughly on hard floor or on their corners. Do not place modules on top of each other. Do not step or stand on modules. Do not place any objects on modules. Do not work on modules with sharp objects; store modules in a dry place. Grounding of module and frame We recommend ensuring the functional grounding of the module metal frame. If an exterior lightning protection system is already provided, the PV system has to be inte- grated into the protection concept against direct lightning stroke. Local standards shall be observed. Grounding in the US and Canada The modules can be connected to the grounding holes using a lay -in lug. The lug can be fixed: A) at the module corner by using a socket head cap screw, or B) at the hole provided in the flange by using a screw with a serrated washer, a washer and a nut. Any grounding method and components listed according to NEC requirements are also acceptable in the US and Canada, Table: Recommended components for grounding in the US and Canada Item - Manufacturer/Description- ' Ti htenin torque Lay -In lug 1D lsco GBL -4DB (E34440) 3S Ibf -in, 4 -6 A \NG str 251bf -in, 8 AWG str 20 Ibf -in, 10 -14 AWG sol /str Socket head cap screw Q 10 -24, 5/8 ", SS 18.8 62 Ibf -in (70 Nm) Bolt Q tt6 -32, SS 25 in -lbs (2.9 Nm) Serrated washer (4) 1 MS, SS Washer Q 1 ID 9/64 ", OD 3/8 ", SS � Nut Q 1#6-32, SS Underwriters Laboratories Information (U.S. and Canada) For the electrical ratings please refer to the datasheet. The fire rating of this modu- le is valid only when mounted in the manner specified in the mechanical mounting instructions. The module is considered to be in compliance with UL 1703 only when the module is mounted In the manner specified by the mounting instructions below. A module with exposed conductive parts is considered to be in compliance with UL 7703 onlywhen it is electrically grounded in accordance with the instructions presented below and the requirements of the National Electrical Code. Where common grounding hardware (nuts, bolts, star washers, spilt -ring lock washers, flat washers and the like) is used to attach a listed grounding /bonding device, the attachment must be made in conformance with the grounding device manufacturer's instructions. Common hard- ware items such as nuts, bolts, star washers, lock washers and the like have not been evaluated for electrical conductivity or for use as grounding devices and should be used only for maintaining mechanical connections and holding electrical grounding devices in the proper position for electrical conductivity. Such devices, where supplied with the ® module and evaluated through the requirements in UL 1703, may be used for groun- ding connections in accordance with the instructions provided with the module. The electrical characteristics are within 310 percent of the indicated values of ISC, VOC, and Pmax under standard test conditions (irradiance of 100 mW /cmr, AM 1.5 spectrum, and a cell temperature of 25'C (77'F)). Under normal conditions, a photovoltaic module is likely to experience conditions that produce more current and /or voltage than reported at standard test conditions. The requirements of the National Electrical Code (NEC) in Article 690 -8 shall be followed to address these increased outputs. In installations not under the requirements of the NEC, the values of ISC and VOC marked on this module should be multiplied by a factor of 1.25 when determining component voltage ratings, conductor ampacities,overcurrent device ratings, and size of controls connected to the PV output. To reduce the operating temperature the module has to be mounted on any surface with a minimum distance of 4 inches (10 cm)- In Canada the installation shall be in accordance with CSA C22.1, Safety Standard for Electrical Installations, Canadian Electrical Code, Part T. Suitable ambient conditions The module is intended for use in moderate climatic conditions. Artificially concentra- ted sunlight shall not be directed on the module or panel. The module must neither be immersed in water nor be exposed to continuous wetting (e.g. by fountains). Exposure to salt or sulfur (sulfur sources, volcanoes) implies a risk of corrosion. The module must not be used for maritime (e.g. boats) or automotive (vehicles) purposes. The module must not be exposed to extraordinary chemical loads (e.g. emissions from manufac- turing plants). If the modules are installed on stables, a distance of 1 m to ventilation openings shall be ensured; apart from this, the modules shall not be used as a direct roof panel on stables. Appropriate installation situation Make sure that the module meets the technical requirements of the overall system. Other system components should not exert any adverse mechanical or electrical influ- ences on the module. Modules may bend under high loads. For this reason, sharp -edged fixing elements or other sharp objects (e.g. cable ties on mounting sections must not be mounted near the module back side. For modules connected in series, only modu- les of the same amperage rating may be used together. For modules connected in parallel, modules with the same voltage ranges must be used together. The modules must not be operated at a higher voltage than the permissible system voltage. The inside opening of the frame corner element is intended for water drainage and must not be blocked. For system documentation, please note the serial numbers. Optimum installation In order to avoid performance losses, all modules connected in series should be arranged with the same orientation and tilt angle. The modules should be installed in an all- season shadow -free area. Even partial shadowing results in yield losses and is to be avoided. Ventilation of the module back side will prevent heat build -up adversely affecting performance - Mounting The modules must be securely fixed at a minimum of 4 locations on the substructu- re. Fixing is only allowed in designated areas or at the provided mounting holes. The- se designated areas for fixing are located on the module long sides. They are located between 1/8 of the module length and 1/4 of the module length, measured from the module corner. Fixing the module on its narrow sides is not sufficient. In regards to "Top- Down" mounting methods, the clamping area on the module frame must be at least 130 mmr (0.20 inr) for each fixing point.. The required clamping pressure is 100 N /mmr (14,5 Ibf /inr). For "Bottom — Up" mounting methods, use a stainless steel serrated lock nut and M8 (5/16 ") bolt to secure the module to the mounting structure with the provided mounting holes. The bolts must be tightened to 20 Nm (15 ft -lbs). Do not drill any holes into the module. Use corrosion -proof fixing material. Electrical connection The modules are provided with factory - assembled cables and connectors. Do not open the junction box in any case, Connectors may only be connected under dry conditions. Make sure to avoid gaps in a plugged connection, Only singlecore solar cables with an adequate cross - section (4 mmr minimum) and appropriate connectors may be used for connecting the modules. Cables should be attached to the installation system by means of UV- resistant cable ties. Exposed cables should be protected against sunlight and damage by suitable precautions (e.g. conduits) In order to limit voltages released by indirect lightning shock, the area of all conductor loops must be reduced to a minimum. Check that wiring is correct (polarityl) prior to starting the generator. Cleaning In general, the modules do not need any cleaning if the tilt angle is sufficient (> 15'; self - cleaning by rain). In case of heavy soiling, it is recommended to clean the modules with plenty of water (low pressure hose) and without the use of cleaning agents. If necessa- ry, a soft cleaning device (sponge) maybe used. Never scrape or rub off dirt as this may result in micro - scratches. Maintenance We recommend regular inspections of the system to ensure that: 1. All fixtures are securely tightened and corrosion -free; 2. Wiring is securely connected, properly arranged and free of corrosion; 3. Cables are free of damage; Please also observe applicable standards. Disclaimer of liability SolarWorld AG does not guarantee the operational capability and functionality of modules if the instructions contained in the present user information are not complied with. Since compliance with these instructions and the conditions and methods of installation, operation, use and maintenance of the modules are not checked or moni- tored by SolarWorld AG, SolarWorld AG accepts no liability for damage arising through improper use or incorrect installation, operation, use or maintenance. Furthermore, lia- bility for infringements of patent law or of other third party rights arising from the use of the modules is excluded unless we are automatically liable by law. Bottom — Up mounting method Fog. C F. min max UL design pressure IEC design pressure at provided F= 30 psf (- 1,4 kN /m') F,,- -50 psf ( -2,4 kN /m') mounting holes F_= + 113 psf (+ 5,4 kN /m') F = +113 psf ( +5,4 kN /m') Top -Down mounting method Fig. E b a Fn max b a min max UL design pressure IEC design pressure a = 9.0 in (229 mm)' F m= - 64 psf (- 3,1 kN /m') F,, = -50 psf ( -2,4 kN /m') b - 33.0 in (838 mm)' IFS,,, =+ 170 psf ( +8,1 kN /m') 'F_ - +113 psf ( +5,4 kN /m') 'tolerance: +/- 0.4 in ( +/- 10mm) Revisions Version Changes 1.0 New document SolarWorld Americas LLC. 4650 Adohr Lane Camarillo, CA 93012 USA Phone: +1805 388 6200 Fax: +1805 388 6395 service @solarworld- usa.com Date 2012 -07 -12 Top -Down mounting method Fig. D b F. min max e a b UL design pressure IIEC design pressure a = 8.2 in (209 mm) F., - 64 psf (- 3,1 kN /m') F,,,= -50 psf ( -2,4 kN /m') b = 16.5 in (419 mm) !F _j +113psf(+5,4kN /m') IF_ - +113 psf ( +5,4kN /m') Top -Down mounting method Fig. F a Fminmax b UL design pressure IEC design pressure a = 20.1 in (510 mm)' Fm,= - 50 psf (- 2,4 kN /m') F.,,= -50 psf ( -2,4 kN /m') b - 8.8 in (223 mm)* Fm „= +113 psf ( +5.4kN /m') 'F,,,..- +113 psf ( +5,4kN /m') 'tolerance: +/- 0.4 in ( +/- 10mm) Jbiiji SOLAR WORLD www.solarworld- usa.com We turn sunlight into power. 10/1(0 % 9ii; 1 %j'r( ✓ "'i % %, %/i // ?Grl�/� /� / % % J/ ?s %; Il f ( t /ii j 111111111, %/ J/ % 1,f' , L SOLARWORLD MODULE TYPES May 19, 2014 1 Issue: 1027 Module Typing of SolarWorld Modules SolarWorld has completed the spread of flame fire performance testing of our photovoltaic modules to classify them to the updated UL 1703 standards. When combined with Class A mounting systems our modules meet the photovoltaic fire system rating of Class A. Module Types There are up to 15 different module types classified by UL. Types are defined by their construction characteristics such as glass thickness, EVAthickness, back sheet thickness and fire performance. Testing Criteria For Class Atesting (the most stringent) the module is positioned to simulate mounting to a ballasted system or sloped roof at 22- degrees and exposed to calibrated flame and wind from a standard distance. The flame is continuously applied to the bottom of the module for 10 minutes. Passing Criteria In orderto passthe spread offlametest: No part of the module can be blown or fall off the deck in the form of flaming or glowing brands No portion of the module or roof deck that forms part of the building can fall away in the form of glowing particles The flame cannot spread laterally on the top surface or intermediate channel such as the space between the module and a roof Flame may not spread beyond the specified distance: Results Sunmodule Plus and Pro - Series: Type 1 s N Sunmodule Pro - Series XL: Type 1 0 N O Sunmodule Protect: Type 3 When combined with a Class A mounting system our modules meet the photovoltaic fire system Class A requirement. o Enphase® Microinverters Enphase °M250 The Enphas' M250 Microinverter delivers increased energy harvest and reduces design and installation complexity with its all -AC approach. With the M250, the DC circuit is isolated and insulated from ground, so no Ground Electrode Conductor (GEC) is required for the microinverter. This further simplifies installation, enhances safety, and saves on labor and materials costs. The Enphase M250 integrates seamlessly with the Engage Cable, the Envoy® Communications Gateway", and Enlighten ®, Enphase's monitoring and analysis software. PRODUCTIVE Optimized for higher -power modules Maximizes energy production - Minimizes impact of shading, dust, and debris [ei enphase° E N E R G Y SIMPLE No GEC needed for microinverter No DC design or string calculation required Easy installation with Engage Cable RELIABLE 4th- generation product - More than 1 million hours of testing and 3 million units shipped Industry- leading warranty, up to 25 years S�® c us Enphasea M250 Microinverter // DATA INPUT DATA (DC) M250- 60- 2LL- S22/S23/S24 Recommended input power (STC) 210 - 300 W Maximum input DC voltage 48V Peak power tracking voltage 27 V - 39 V Operating range 16 V - 48 V Min /Max start voltage 22 V / 48 V Max DC short circuit current 15 A Max input current 9.8 A _ � � � � OUTPUT DATA (AC) _...- - �..._.., �... . .- .._......_- @208 VAC @240 VAC .�.260. Peak output power W 250.W Rated (continuous) output power Nominal output current Nominal voltage /range Nominal frequency /range Extended frequency range' Power factor 240 W 1.15 A (A rms at nominal duration) 208 V / 183 -229 V 60.0 / 57 -61 Hz 57 -62.5 Hz >0.95 240 W 1.0 A (A rms at nominal duration) 240 V / 211 -264 V 60.0 / 57 -61 Hz 57 -62.5 Hz >0.95 Maximum units per 20 A branch circuit 24 (three phase) 16 (single phase) Maximum output fault current 850 mA rms for 6 cycles 850 mA rms for 6 cycles EFFICIENCY CEC weighted efficiency, 240 VAC 9�6. 5% .._ �. o���������- �o�,..._. �, �- �a. ��- �_ ��..___. ��.- �-._ ��������., �. �,-___ �. ��. w. �.. .��..- ,�.�- �.�_.�„�..,.��� -���. CEC weighted efficiency, 208 VAC 96.0% Peak inverter efficiency 96.5% Static MPPT efficiency (weighted, reference EN50530) 99.4% Night time power_ consumption 65 mW max MECHANICAL DATA Ambient temperature range -401C to +651C Operating temperature range (internal) -40 °C to +85 °C Dimensions (WxHxD) 171 mm x 173 mm x 30 mm (without mounting bracket) Weight 2.0 kg Cooling Natural convection - No fans Enclosure environmental rating Outdoor - NEMA 6 FEATURES Compatibility Compatible with 60 -cell PV modules. Communication Integrated ground Power line The DC circuit meets the requirements for ungrounded PV arrays in NEC 690.35. Equipment ground is provided in the Engage Cable. No additional GEC or ground is required. Monitoring Free lifetime monitoring via Enlighten software Compliance UL1741/IEEE1547, FCC Part 15 Class 8, CAN /CSA -C22.2 NO. 0-M91, 0.4 -04, and 107.1 -01 Frequency ranges can be extended beyond nominal if required by the utility To learn more about Enphase Microinverter technology, enphase° visit enphase.com E N E R G Y © 2013 Enphase Energy. Al rights reserved. Al trademarks or brands in this document are registered by their respective owner. Magerack Technical Datasheet L -foot with Flashing Parts: Material: Extruded aluminum alloy 6061 -T6, aluminum One (1) L -foot or Tall L -foot 3003 -H14 One (1) rail nut Finish: Mill finish, clear or black anodized One (1) 5/16 X 1" stainless steel bolt /washer Ultimate Tensile: 38 ksi One (1) 5/16 X 1/2" stainless steel bolt /washer Yield: 35 ksi One (1) L -foot flashing (12 "x12 ") Installation: Use anti -seize and tighten to 12 ft-lbs of torque Load: Loads are given for the L -Foot to beam connection r only; be sure to check load limits for L -foot, lag screw, or other attachment method. +b ultgl��;� �,,IIllll 101 - 006 -101 L -foot with flashing (L -foot, rail nut, 1" Clear 3.5" - 4.2" 0.665 bolt /washer, flashing, 1/2" bolt ...... .._...... - . .................. 101- 006 -102 ! Tall L -foot with flashing (Tall L -foot, rail nut, 4.5" 5.2" 0.705 1" bolt /washer, flashing, 1/2" bolt /washer) (114 - 132 mm) .__... .. ..... ..._ . ._ .................... 101 - 019 -101 L foot with flashing only (L -foot, flashing, 1/2 ! 2.24" — 2.87" 0.575 bolt /washer) (56.9 -72.9 mm) ** 101 - 019 -102 Tall L -foot with flashing only (Tall L- foot, 3.24" — 3.87" 0.615 flashing, 1/2" bolt /washer) (82.3 -98.3 mm) ** 101 -006 -201 L -foot with flashing (L -foot, rail nut, 1" Black 3.5 - 4.2" 0.665 bolt /washer, flashing, 1/2" bolt /washer) (89 - 107 mm) .- .... „(,. ..._....... ....... .. ...... 101- 006 -202 Tall L -foot with flashing Tall L -foot, rail nut, 4.5 - 5.2" 0.705 1" bolt /washer, flashing, 1/2" bolt /washer) (114 - 132 mm) * Height is the spacing between rail top and attachment bottom (the space clearance between bottom of PV module frame and attachment bottom). ** The height is the spacing between bolt slot and attachment bottom. www,magerack.com " s MAGERACK ales @magerack.com 510 - 656 -6661 w, s- Magerack Technical Datasheet Rails /j � wn /old % /i /i✓ rjl Material: Extruded aluminum alloy 6061 -T6 Finish: Clear or black anodized Ultimate Tensile: 38 ksi Yield: 35 ksi Installation: Use anti -seize and tighten to 12 ft -lbs of torque Warranty: 10 -year limited warranty 101 -001 -110 10.5' (126 ") Clear 9.13 101 - 001 -112 12'(144 ") 10.43 101 - 001 -114 14'(168 ") 12.17 101 -001 -117 ! 17' (204 ") 14.77 101 - 001 -120 20'(240 ") 17.38 101 - 001 -210 10.5' (126 ") Black 9.13 101 - 001 -212 12'(144 ") 10.43 101- 001 -214 ! 14' (168 ") 12.17 101 -001 -217 17' (204 ") 14.77 101 -001 - 220 ! 20' (240 ") 17.38 www.magerack.com MAGEMCK 510- 656 -6661 Stamped Bonding Lug ERITECHO brand of solar bonding lugs are designed to bond the frames and mounting structures of solar photovoltaic systems in accordance with NEC® requirements. These lugs are corrosion- resistant and galvanically compatible with copper grounding conductors and aluminum photovoltaic module frames. The solar bonding lugs are supplied with the required mounting hard- ware and are easy to install. The stamped lug has a lay -in feature that allows the positioning of the grounding conductor along multiple frames prior to securing the wire. In addition, the same hex head power driver can be used to install the lug to the frame and secure the wire into the lug. Part Number Conductor Range Material Approva Is: C UL US LISTED cULus is a. registered trademark of Underwriters Laboratories, Inc. NEC is a registered trademark of, and National Electrical Code ON EC*) standard is a copyright of the National Fire Protection Assodatiom WARNING ERICO products shall be installed and used only as indicated in ERICOY product instruction sheets and training materials. Instruction sheets are available at www.efico.com and from your ERICO customer service representative. Improper installation, misuse, misap- plicationorother failure to completely follow ERICO's instructions and warnings may cause product malfunction, property damage, serious bodily injury and death,. Copyright 02009, 2010 ERICO International Corporation. All rights reserved. CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH, and LENTON are registered trademarks of ERICO International Corporation. www.erico.com ERIMCOO E979S•WWEN WILTIOWWEN IOM091O Product Data Sheet HOM612L100RB Load Center 100A, Fixed - Factory installed main lugs, 6, 6, Outdoor /Rainproof, 2R Technical Characteristics M t =tJARE 13 by Schrw4der Hiccc, i c List Price $129.00 USD Availability Stock Item: This item is normally stocked in our distribution facility. Ampere Rating 100A Bus Material Tin Plated Aluminum Enclosure Type Outdoor /Rainproof Box Number 2R Enclosure Rating NEMA 3R Main Type Fixed - Factory installed main lugs Grounding Bar Order separately Maximum Single Pole Circuits 12 Application Designed to meet residential, commercial and industrial requirements to protect electrical systems, equipment and people. Approvals UL Listed Short Circuit Current Rating 10kA Cover Type Combination Flush /Surface Marketing Trade Name Homeline Maximum Tandem Circuit Breakers 6 Phase 1 -Phase Depth 4.27 Inches Spaces 6 Voltage Rating 120/240VAC Wire Size #8 to #1 AWG(AI /Cu) Wiring Configuration 3 -Wire Height 12.65 Inches Width 8.88 Inches Notes: 70A (max) branch circuit breaker and 100A (max) back fed main circuit breaker. Shipping and Ordering Category 00149 - Load Centers, NEMA1 & 3R, 2 - 8 Circuits, Type HOM Discount Schedule DE3C GTIN _ 00785901061205 _ Package Quantity 1 Weight 9.92 lbs. Availability Code Stock Item: This item is normally stocked in our distribution facility. Generated: 03/30/2011 14:09:04 nr 0 2011 Schneider Electric. All rights reserved. C fgh tl Retumability Y Country of Origin MX As standards, specifications, and designs change from time to time, please ask for confirmation of the information given in this document. Generated: 03/30/2011 14:09:04 m 2011 Schneider Electric. All rights reserved. Schneider E :r,r , IN o ll 7, p Aw 0' 5 U.J Mi �5 -5 ci I Ull L,,, I ; 2 rv, I Lll o Lu m 'n- mRm LU D- u -A 0 - -- -- ----------- oi- V7 0 T 10, i Ou tom! 2,i Nq� Wv LTC t� HVI lu LL LL