Loading...
15080006. CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 21451 MILFORD DR CONTRACTOR: BAY AREA SOLAR PERMIT NO: 15080006 SOLUTIONS OWNER'S NAME: RAMA ARUN AND BHUVANA 6700 SANTA RITA RD #E DATE ISSUED: 08/03/2015 OWNER'S PHONE: 4088009623 PLEASANTON, CA 94588 PHONE NO: (510) 293-0366. LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL ❑ COMMERCIAL License Class �(a52 INSTALL NEW SOLAR ROOF MOUNTED PV - 16 PANELS Lic. # (4.24KW), INSTALL NEW 125 AMP SUB PANEL j tt Contractor & t4m _Z /.y S0 6gh`vSate 3 ( 5 I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the Sq. Ft Floor Area: Valuation: $12600 performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. APN Number 32641108.00 Occupancy Type: APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter WITHIN 180 DAYS OF PERMIT ISSUANCE OR upon the above mentioned property for inspection purposes. (We) agree to save 180 DAYS FROM LAST CALLED INSP C ION. indemnify and keep harmless the City of Cupertino against liabilities, judgments, t costs, and expenses which may accrue against said City in consequence of the 1 VIAJ granting of this permit. Additionally, the applicant understands and will comply Issued by: Date: 13MT6_ with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. RE -ROOFS: Signature Date ! All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. ❑ OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of Signature of Applicant: Date: the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) I, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(a) should I store or handle hazardous I have and will maintain a Certificate of Consent to self -insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and I have and will maintain Worker's Compensation Insurance, as provided for by the Health & Safety Code, Sections 255 5533, and 25534. Section 3700 of the Labor Code, for the performance of the work for which this / Owner or authorized agent: Date: permit is issued. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code, I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section Licensed Professional 9.18. Signature Date ALTERNATIVE ENERGY PERMIT APPLICATION ka COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • buildinaCc?cupertino.org PROJECTADDRESS�%� 5( /�/1`kd �c APNR5y /O OWNERNAME �X� n L- PHONE Q�(iL 11� E-MAIL t��V �/ STREET ADDRESS a`�WV�_IQO�C� FAX CONTACT NAME PHO A� �S J E-AL+II. 2 �I �[rnoy4anecn STREET ADDR SSI n I _ _ / CiT ATS p _ c� FAX dO ❑ OIIT7ER ❑ OWNER -BUILDER ElOWNMRAGENT 11 CONTRACTOR I CON'�PACTORAG(E�NT 11ARCOHITiCS ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NATO Gl. 2Gr j�� f LICENSE T IBEX LICENSE TIM •, � (�[ l rG BUS. LIC R COMPANY NAME E-MAIL FAX STREET ADDRESS U .19 Ar)r, CITY, ZI�t TCS' PHONE ARCMTECTIENGINEER NAME LICENSE NUMBER I BUS. LIC R COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE USE OF SFD or Duplex ❑ Multi -Family PROJECT IN WILDLAND PROJECT IN STRUCTURE: ❑ Commercial URBAN INTERFACE AREA ❑ Yes ❑ NO FLOOD ZONE ❑ Yes ❑ NO fjdZOLAX PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER I',EATING ❑ OTHER: FOR SOL4R PANELS: NUMBER OF PANELSIUNITS: KILOWATTS (COMA4ERCIAL ONLY): TOTAL VALUATION .I r/ (/ DESCRIPTION OF WORK 1 L `J IJU J 1 ZS �1 �,6km {_ ... .• nREGEIVE]�IY ' 0010 i By my signature below, I certify to each of the following: I am the property oHmer or authorized went to act on the property er's behalf. I have read this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to buildin cc uthorize representatives of Cupertino to enter the above -id gro� for inspection purposes. �lified Signature of Applicant/Agent: Date: PLEMENTAL INFORMATION REQUIRED 4 .r�C.r� � FIR DR>�ss" ma U, it} k frsz-, sz- P114pp_2011.doc revised 03/16/11 CITY OF CUPERTINO 1508 FEE ESTIMATOR - BUILDING DIVISION NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School District, etc.). These fees are based on the preliminary information available and are only an estimate. Contact the Dent for addn'1 info. FEE ITEMS (Fee Resolution 11-053 Eff. 711113J ADDRESS: 21451 MILFORD DATE: 08/03/2015 REVIEWED BY: PAUL A-Icc/:. Permit bee: APN: 326 41 108 BP#: *VALUATION: 1$12,600 '''PERMIT TYPE: Building Permit PLAN CHECK TYPE: Addition PRIMARY SFD or Duplex USE: Plumb. Insp. Fee: PENTAMATION SOLAR -RES PERMIT TYPE: A WORK Install new solar roof mounted PV - 16 Panels 4.24K Install new 125 Amp Sub Panel SCOPE NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School District, etc.). These fees are based on the preliminary information available and are only an estimate. Contact the Dent for addn'1 info. FEE ITEMS (Fee Resolution 11-053 Eff. 711113J 1:Iech. Pkat Cheek Ph nth. Plan Check Elec. PlanCheck 0.0 hrs $0.00 A-Icc/:. Permit bee: PltrmG. I'ermir Fee: Elec. Permit Fee: IEPERMIT Other _t Tech. Insp. Other Plumb .hasp. j Other Elec. Insp. 0.0 hrs $48.00 Heeh. Insp. Fee: Plumb. Insp. Fee: Elea hasp, Fee: NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School District, etc.). These fees are based on the preliminary information available and are only an estimate. Contact the Dent for addn'1 info. FEE ITEMS (Fee Resolution 11-053 Eff. 711113J FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 0 # $236.00 Alternative Energy System IPHOTOVRE Photovoltaic System Suppl. PC Fee: 0 Reg. 0 OT 0.0 hrs $0.00 PME Plan Check: $0.00 Lj_?5j amps $48.00 Electrical IBELEC200 Services Permit Fee: $0.00 Suppl. Insp. Feer Reg. 0 OT0 0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $48.00 C onstruclion Tax: F_ Administrative Fee: 1ADMIN $45.00 0 E) Work Without Permit? 0 Yes (E) No $0.00 Advanced Planning Fee: $0.00 Select a Non -Residential Building or Structure G 0VDOC � Travel Documentation Fee: ITRA $48.00 Strong Motion Fee: IBSEISMICR $1.64 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $1.00 ---- SUBTOTALS:`' $143.64 $284.00TOTAL y ry FEE'` $427.64 Revised: 07/02/2015 FA SMOKE / CARBON MONOXIDE ALARMS OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISION 10300 TORRE AVENUE - CUPERTINO, CA 95014-3255 (408) 777-3228 - FAX (408) 777-3333 - buildinga-cuDertino.og FILE `1-36-11 1341-C q� Permit No. / S0 Y�O` Address , / t �� 1 ISI 1' # of Alarms Smoke: Carbon Monoxide: PERMIT CANNOT BE FINALED AND COMPLETED UNTIL THIS CERTIFICATE HAS BEEN SIGNED AND RETURNED TO THE BUILDING DIVISION PURPOSE This affidavit is a self -certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R314, 2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single-family and multi -family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds $1000.00, CRC Section R314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations: AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of the bedroom(s) X X On every level of a dwelling unit including basements X X Within each sleeping room X Carbon Monoxide alarms are not required in dwellings which do not contain fuel -burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. Power Supply: h -i dwelling units with no commercial power supply, alarm(s) may be solely battery operated. In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl space. Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2. An electrical permit is required for alarms which must be connected to the building wiring. As owner of the above -referenced property, I hereby certify that the alarm(s) referenced above has/have been installed in accordance with the manufacturer's instructions and in compliance with the California Building and California Residential Codes. The alarms have been tested and are operational, as of the date signed below. I have read and aoree to comply with the ter=sand conditions of this statement Owner (Owner Agent) Name: G� Signature's ...wa..........4-e ......................................... Date '.l...3D t. S. Contractor Name: Signature........... ................ ........................................ Lic.#......................................Date:.................... Smoke and CO form.doc revised 03/14/14 CUPERTINO Owner N Address WATER -CONSERVING PLUMBING FIXTURES OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 1. Is your real property a registered historical site? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply ❑ No Go to Question 2. Skip the rest of the form and sign bottom of form. 2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its plumbing, installation of water -conserving plumbing fixtures is not technically feasible? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. ❑ The licensed plumber's certification has been provided to the Building Division. Skip the rest of the form and sign bottom of form. ❑ No Go to Question 3. 3. Is water service permanently disconnected for your building? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. ❑ No Go to Question 4. 4. Is your real property built and available for use or occupancy on or before January 1, 1994? ❑ No My real property is built and available for use or occupancy after January 1, 1994. Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. ❑ Yes My real property is built and available for use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101.8 apply. Check one of the three following statements and sign bottom of form.. Please check ONE of the following: ❑ My property is a single-family residential real property. See Civil Code Section 1101.4. On and after January 1, 2014, building alterations or improvements shall require all non-compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non- compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements). ❑ My property is a multifamily residential real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water - conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). ❑ My property is a commercial real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). I, as the owner or owner's agent of this property, certify under penalty of perjury that non-compliant plumbing fixtures will be replaced prior to date specified above with water -conserving plumbing fixtures in accordance with Civil Code Sections 1101.1 through 1101.8, the current California Plumbing Code and California Green Building Standards Code, and manufacturer's installation requirements, and that the water -conserving pl fixtures comply with the requirements as indicated in the table on the following page. r Owner or Owner Agent's Signature: Date: 11 I'l0I IS Upon completing and signing this Certiticate, please return it to the Building Division in order to final your building permit. SB407 2015.doc revised 08126/15 _BUILDING PEIZA1IT CANNOT BE FINALED AND COMPLETED UNTIL THIS _. ,.LF,IAIJFICATE HAS BEEN SIGNED AND RETURNED TO THE BUILDING DIVISION 1. If the existing plumbing fixture water usage/flow rate is equal to or lower than the figure shown, it is not required to be upgraded. SB407 2015.doc revised 08/26/15 Non -Compliant Water -Conserving Plumbing Fixture Plumbing Fixture/ (Fixture Complying with Current Code Applicable to New Construction) Maximum Water Usage/Flow Rate Fixture Type 2013 CPC Ch. 4 2013 CPC Ch. 4 2013 CPC Ch. 4 Water Usage 2013 CALGreen Div. 4.3 2013 CALGreen Div. 4.3 2013 CALGreen Div. 5.3 /Flow Rate Single -Family Multi -Family Commercial Residential Residential Water Closets Exceed 1.6 Single flush toilets: 1.28 gallons/flush (Toilets) Gallons/flush Dual flush toilets: 1.28 gallons/flush effective flush volume (the composite, average flush volume of two reduced flushes and one full flush Urinals Exceed 1.0 0.5 gallons/flush Gallons/flush Showerheads Exceed 2.5 2.0 gallons per minute @ 80 psi. Also certified to the performance criteria of gallons per minute U.S. EPA WaterSense Specification for Showerheads (A hand-held shower is considered a showerhead.) For multiple showerheads serving one shower, the combined flow rate of all showerheads and/or other shower outlets controlled by a single valve shall not exceed 2.0 gallons per minute @ 80 psi, or the shower shall be designed to allow only one shower outlet to be in operation at a time. Faucets — Exceed 2.2 gallons Maximum 1.5 gallons per Within units: 0.5 gallons per minute @ 60 Lavatory per minute minute @ 60 psi; minimum Maximum 1.5 gallons psi Faucets 0.8 gallons per minute @ per minute @ 60 psi; 20 psi minimum 0.8 gallons per minute @ 20 psi In common and public use areas: 0.5 gallons per minute @ 60 psi 1.8 gallons per minute 60 psi Faucets — Exceed 2.2 gallons 1.8 gallons per minute @ 1.8 gallons per minute 1.8 gallons per minute @ 60 Kitchen per minute 60 psi @ 60 psi psi Faucets May temporarily increase May temporarily up to 2.2 gallons per increase up to 2.2 minute @ 60 psi, and must gallons per minute @ default to maximum 60 psi, and must 1.8 gallons per minute @ default to maximum 60 psi 1.8 gallons per minute Where faucets meeting @ 60 psi the above are unavailable, Where faucets meeting aerators or other means the above are may be used to achieve unavailable, aerators or reduction. other means may be used to achieve reduction. 1. If the existing plumbing fixture water usage/flow rate is equal to or lower than the figure shown, it is not required to be upgraded. SB407 2015.doc revised 08/26/15