Loading...
15060052-VOIDC'. CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 7733 RAINBOW DR CONTRACTOR: REC SOLAR, INC. PERMIT NO: 15060052 OWNER'S NAME: BREILING JAMES G AND MARY J 775 FIERO LN STE 200 DATE ISSUED: 06/08/2015 OWNER'S PHONE: 4084162160 SAN LUIS OBISPO, CA 93401 PHONE NO: (888)657-6527 LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL COMMERCIAL License Class C' `1 L �J� INSTALL 34 ROOF TOP, FLUSH MOUNTED MODULES Lie. # (8.8KW) Contractor l S & UPGRADE (E) ELECTRICAL PANEL TO 125 AMPS (SAME ate LOCATION) I hereby affirm that 1 am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the Sq. Ft Floor Area: Valuation: $18400 performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. APN Number: 36224017.00 Occupancy Type: APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter WITHIN 180 D IT ISSUANCE OR upon the above mentioned property for inspection purposes. (We) agree to save ICA D SPECTION. indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply slue Date: l with all non -point source regulations per the Cupertino Municipal Code, Section 9 18. Sig ure Date � �_ �� RE -ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. ElOWNER-BUILDERDECLARATION 1 hereby affirm that I am exempt from the Contractor's License Law for one of Signature of Applicant: Date: the following hreasons: 1, as owner of thee property, or my employees with wages as their sole compensation, ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) 1, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the 1 hereby affirm under penalty of perjury one of the following three California Health & Safety Code, Sections 25505, 25533, and 25534. 1 will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: 1 have and will maintain a Certificate of Consent to self -insure for Worker's Health & Safety Code, Section 25532(a) should I store or handle hazardous Compensation, as provided for by Section 3700 ofthe Labor Code, for the material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District 1 performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and 1 have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this/ the Health & Safety Code, Sectioqt 25505, 25533, and 25534. I t permit is issued. Owner or authori d Date: 1 ! I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, 1 CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code, I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name Lender's Address APPLICANT CERTIFICATION 1 certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, ARCHITECT'S DECLARATION costs, and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records, granting of this permit. Additionally, the.applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section Licensed Professional 9 18. Signature Date ALTERNATIVE ENERGY PERMIT APPLICATION AM COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • buiiding(GDcupertino org �sa600-�__2- PROJECT ADDRESS 3 APN 11 / 2 � ^ OWNERNAI4E n,PHONE (, JT \^�__< ��� Ll E-MAIL STREET ADDRESS '� �t'7 A INCTTY,, TATE, ZIP ( FAX 1�t CONTACT NAME PHON E-MAIL U.al e. b�� �{�� ��-`i'Lt-L' e��eit,�� r^�e.Cabe�1 SJvv �.,ti STREET ADDRESS 2D �C'Ty. STATE,ZIP FAX�`��79 S��e ❑ OWNER ❑ OWNER -BUILDER ❑ OWNER AGENT CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ENGIN.'EER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME / _ _ LICENSE NUMBER LICENSE TYPE BUS. LIC � Kf W\ �vGc� TLIL C—Nio COMPANY NAME E-MAIL 5uv.r��G S� FAX I.kC_co-L- STREET ADDRESS CITY, STATE, Zl P ONE ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS. LIC,1 COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE USE OF ❑ SFD or Duplex Cl Multi -Family PROJECT TN WILDLAND [FLOOD JECT IN STRUCTURE: ❑ Commercial URBAN INTERFACE AREA ❑ Yes ❑ NO ZONE ❑ Yes ❑ No SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER: FOR SOLIRPANELS: NUMBER OF PANELS/UNITS: 3,r KILOWATTS COMMERCIAL ONLY): TOTAL VALUATION: DESCRIPTION OF WORK jOLa� too By my signature below, I certify to each of the following: I am the property owner or authorized ag o��mer's behalf. 1 have read this application and the information I have provide is correct. I have read the Description of Work and verif, it i curate I agree to comply with all applicable local ordinances and state laws relating to b nstruction. IN, of Cupertino to enter the above -id e tified roperty for inspection purposes. Signature of Applicant/Agent: Date: S � SUPPLEMENTAL INFORMATION REQUIRED P114pp_2011.doc revised 03/16/11 � � CITY OF CUPERTINO IIV�+ A7 F RIP F.CTIMATOR — BUILDING DIVISION rJ' J4�� v!� • 3_; ' �� 5 h �.. '� P� r�l�li" f�T Jw1. ,r T f ���X tL ,.tll� F it ��itl+'tll�r i,f, '1 {-. : ADDRESS: 7733 RAINBOW DR DATE: 0610812015 REVIEWED BY: MELISSA /'rrn,rl f APN: 362 24 017 BP#: -VALUATION: 1$18,400 Ll .kPERM1T TYPE: Building Permit PLAN CHECK TYPE: Alteration /Repair PRIMARY SFD or Du lex USE: p PME Plan Check: PENTAMATION SOLAR -RES PERMIT TYPE: i WORK INSTALL 34 ROOF TOP FLUSH MOUNTED MODULES (8.8kM & UPGRADE E ELECTRICAL SCOPE PANEL TO 125 AMPS (SAME LOCATION) rJ' J4�� v!� • 3_; ' �� 5 h �.. '� P� r�l�li" f�T Jw1. ,r T f ���X tL ,.tll� F it ��itl+'tll�r i,f, '1 {-. : :kfe, b. Nall Check !'Irwrh. I'lcr„ C,',f. c.4 Elec. Plan Check 0.0 hrs $0.00 /'rrn,rl f I'lumh. 1'dr,nit I' t:: Elec. Permit Fee: IEPERMIT a/rc1r. rc> 0.0 hrs $0.00 PME Plan Check: Elec. Insp. 0.0 hrs $48.00 ..Other [,),Ich Permit Fee: $0.00 lisp. Fire: Ahnul'r. l,rsp. (c'r: / l<:c. /rtrp. /'' fr: n_L_1 NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, fire, SantrarySewer ursincy auff of n.- _J* Tl eas b ed on the relitnina in ormation available and are onlv an estimate. Contact the Dept for addn'l info. , eta . rese ees ar FEE ITEMS (Fee Resolution 11-053 E.' 7./1/13) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 L__I_j # Alternative Energy System $236.001 IPHOTOVREs Photovoltaic System Suppl. PC Fee: Q Reg. Q OT 0.0 hrs $0.00 PME Plan Check: $0.00F!$48.00 amps Electrical I IBELEC200 I Services Permit Fee: $0.00 Supp]. Insp. Fee -0 Reg. Q OT Q,0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $48.00 7,ux: Administrative Fee: IADMIN $45.00 0 0 Work Without Permit? Yes (j) No $0.00 Advanced Planning Fee: $0.00 Select a Non -Residential G Building or Structure Travel Documentation Fee: ITRA VDOC $48.00 Strong Motion Fee: IBSEISMICR $2.39 Select an Administrative Item Bldg 3tds Commission Fee: IBCBSC $1.00 SUBT,OTALS�, V. $144.39 $284.00 �TQTALa'EE $428.39 Revised: 05/07/2015 GENERAL NOTES ALL WORK SHALL COMPLY WITH 2013 CEC, 2013 CBC, 2013 CRC, MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2013 CEC. ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH 2013 CEC. PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(E) AND 2012 IFC 605.11.2. ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. 9.01 AMPS MODULE SHORT CIRCUIT CURRENT. 14.07 AMPS DERATED SHORT CIRCUIT CIRCUIT (690.8 (a) & 690.8 (b)). =`LOT PLA CHECKED BY UA Oiler DATE - PLANNING DEPT CUPERTINO 00 G COMMUNITY DEVVISION - ELOpMENOu DEPARTMENT COM BUILDINGAPPRoVED ecifications MUST be kept at the This set of plans and sP construction. It is unjawful to mak any job site during Building Official. changes or alteratiooval fro ame, or to deviate without approval �s SH.�) L NOT therefrom, tion The Stamping of this pia r he held to per r t e or State Law. ., LEGEND AND ABBREVIATIONS nSE SERVICE ENTRANCE 18-1 MAIN PANEL F&I SUB-PANEL LC PV LOAD CENTER SM SUNRUN METER PM DEDICATED PV METER DC DC DISCONNECT(S) D CB COMBINER BOX F -]INTERIOR EQUIPMENT LE ]1 SHOWN AS DASHED TABLE OF CONTENTS PAGE # I DESCRIPTION SOLAR MODULES PV -1.0 COVER SHEET RAIL PV -2.0 SITE PLAN PV -3.0 LAYOUT PV -4.0 ELECTRICAL STANDOFFS & PV -5.0 SIGNAGE FOOTINGS CHIMNEY INVERTER(S) WITH INV INTEGRATED DC AFCI DISCONNECT AND AFCI AC LEad AC DISCONNECT(S) DC DC DISCONNECT(S) D CB COMBINER BOX F -]INTERIOR EQUIPMENT LE ]1 SHOWN AS DASHED TABLE OF CONTENTS PAGE # I DESCRIPTION SOLAR MODULES PV -1.0 COVER SHEET RAIL PV -2.0 SITE PLAN PV -3.0 LAYOUT PV -4.0 ELECTRICAL STANDOFFS & PV -5.0 SIGNAGE FOOTINGS CHIMNEY - PL- PROPERTY LINE SCALE: NTS A ATTIC VENT AC ALTERNATING CURRENT AFCI JUN 08 2015 (� FLUSH ATTIC VENT o PVC PIPE VENT �Y ® METAL PIPE VENT EXT EXTERIQ�; JUN' 0 8 2015 T -VENT FRAMING INT SATELLITE DISH LBW LOAD BEARING WALL FIRE SETBACKS MAGNETIC Reviewed MSP HARDSCAPE \ - PL- PROPERTY LINE SCALE: NTS A AMPERE AC ALTERNATING CURRENT AFCI ARC FAULT CIRCUIT INTERRUPTER COMP COMPO' z �+IJI�CERTINO P3ull('4'n9 DC DIRECT'., R k DEiPaftGnt (E) EXISTINr-' EXT EXTERIQ�; JUN' 0 8 2015 FIRM FRAMING INT INTERIO%VIEWED FUK t aDE corviPL�ANCE LBW LOAD BEARING WALL MAG MAGNETIC Reviewed MSP MAIN SERVICE PANEL (N) NEW NTS NOT TO SCALE OC ON CENTER PRE -FAB PRE -FABRICATED PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC TL TRANSFORMERLESS TYP TYPICAL V VOLTS W WATTS 01717 I nin IN Ar -A .-.... ...�.,r.. sunrun CA CL #750184 2300 ZANKER ROAD, UNIT F, SAN JOSE, CA 95131 PHONE 408.746.3062 FAX 408S94 9294 CUSTOMER RESIDENCE: JAMES BREILING 7733 RAINBOW DR CUPERTINO CA USA 95014 TEL. (408) 446-2160 APN #:36224017 PROJECT NUMBER: 102R-733BRE1 I DESIGNER: I M. SHAWGO DRAFTER: DI SHEET REC PEAK ENERGY SERIES 991-81 T T -- -- --- - - - 8 - -- - -- - -- ----- •D' Nominal Power- P pp(Wp) ' EFFIOENCY A 27.7 28.1 28.3 28.5 29A 29-4 ! 6.58 6.64 6-68 6-77 6.81 6-90 Open Circuit Voltage-Voc V) 34.4 34.7 35.0 353 35-7 36.0 Short Circuit Current - Isc(A) I 7.08 7.12 7.21 7-24 7.30 Nominal operating cell temperature NOCT YEAR PRODUCT WARRANT 1.5, windspeedI m/s, ambient temperature 20`4 E YEAR LINEAR POWER OUTPUT WARRANT`( US IMPORT DUTY FREE 9A3 F Mounting holes TEMPERATURE RATINGSf + t i Nominal Operating Cell Temperature(NOCT) 45.7°C(;2`C) Temperature Coefficient of P,,, -0.40%/'C 177 Temperature Coefficient of Vx -0.27 %/'C 4 Temperature Coefficient of 1, 0-024%/'C All measurements in inches ELECTRICAL DATA@ STC REC240PE•• OGENERALDATA Nominal Power- P,,,, (Wp) 240 245 250 255 .260 265 Cell Type: 60 REC PEmulti-crystalline Watt Class Sorting -(W) 0/+5 0/+5 0/+5 0/+5 01+5 01+5 3 strings of 20 cells with bypass diodes Nominal Power Voltage V,,,, (V) 29.7 30.1 30.2 305 30.7 30.9 Glass: 1/8'mmsolarglasswith anti -reflection surface treatment Nominal Power Current-ImpP(A) 8,17 8.23 830 8.42 850 8.58 Back Sheet: Double layer highly resistant polyester Open Circuit Voltage-Voc(V) 36.8 37.1 37.4 37.6 37.8 3&1 Frame: Anodized aluminum (silver) Short Circuit Current -Isr(A) 8.7S 8.80 8.86 8.95 9.01 9.0B )unction Box: IP67rated Panel Efficiency (°.U) 14.5 14.8 15.1 155 15..8 16_1 4 mm2 solar cable, 35'+47' Connectors: Multi-ContactNIC4(4mm2) Analysed data demonstrates that 99.7%of panels produced have current and voltage tolerance of±-_-%fmrn rm-mrtail vahw-5 Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W/m2, cell temperature 25`14 Origin: Made in Singapore At low irradiance of 200 W/m2 (AM'1.5 and cell temperature 25'C) at least 96%°f the STC parcel of%riency vrill be achieved. ELECTRICAL DATA@ NOCT REC240PE0' •D' Nominal Power- P pp(Wp) 183 187 189 193 197 202 Nominal Power Voltage - V,,,, (V) 27.7 28.1 28.3 28.5 29A 29-4 Nominal Power Current -I,p(A) 6.58 6.64 6-68 6-77 6.81 6-90 Open Circuit Voltage-Voc V) 34.4 34.7 35.0 353 35-7 36.0 Short Circuit Current - Isc(A) 7.03 7.08 7.12 7.21 7-24 7.30 Nominal operating cell temperature NOCT (800 W/m2, AM 1.5, windspeedI m/s, ambient temperature 20`4 MAXIMLIMRATINGS Operational Temperature: -40...+85'C Maximum System Voltage: 600V Design Load': 75.21bs/ft2 (3600 Pa) Max Series Fuse Rating: Max Reverse Current: 33.4 lbs/ft2 (1600 Pa) Refer to installation maaral 15 A 15A CERTIFICATION C� � 10 year pro linear owero ty. Dimensions: 65'/2x39xlU2in �L us 25 year linear power output warranty Area: 17314ft2 LISTED (max. degression in performance of G3% p.a i, IEC61215,IEC6]730&- 1703:IEC62716(Ammnnia Weight: 391/2 lbs Resistance) IEC 61701 (Salt Mist- severity levels 1 & 61 Note! All given specifications are subject to change IEC 60068-2-68 (Slowing Sand) without notice atany time. REC isaleadingglobalprovider ofsolar energy solutions. With more than 15 years ofexpertence>weofiersurstainable,high performifq products, services and investments for the solar industry. Together with our pal -triers, we create value by providing solutions that REC better meet the world's growing energy needs. RE C is headquartered in Norway and listed on the Oslo Stock Exchange (ticker: RECS0Q_ Our 1,600 employees worldwide generated revenues of USD 647million in 2013_ ymwxecgmptam MECHANICAL INSTALLATION FIRE GUIDELINES REC Peak Energy Series aanels gave a Class C, Type I F re class;fication. The fire rating of this panel is only valid when mounted in the manner specii6ed in these mechanical mounting instructions. Utilize the following fire safety guidelines when installing REC Peak Energy Series panels: • Check with local authorities for fire safety guidelines and requirements for any building or structure onto which the panets Will be instailled.. • The system design should ensure that it can be easily accessed in ttae event of a building fire. • Check with local authorities for applicable regulations concerning setbacks of other placement restrictions that rnay apply for roof- mounted arrays.. • The use of DC ground fault interrupters is recommended. This may also be required by local and national codes. • All electrical appliances are a fire risk. The panel should therefore be mounted over a fire retardant roof covering rated forthe applicaiion and' a suitable distance of 4 in between the panel and the rnountingsurface, allowingfree Circulation of air beneath the panels., should be respected at all times. ORIENTATION To maximize system output, panels should be installed at the optimum orientation and tilt angle. The specifics of this depend an location and can he calculated by a qualified system designer. A lower angle of panel installation increases the requirement for regular cleaning. The optimal mounting position of panels results in the sun's rays falling perpendicular (i.e. at 90") to the surface. All panels in a string should, wherever possible, have the same orientation and tilt to ensure the system does not underperform due to mismatched outputs. 1 The panels must not be exposed to artificially concentrated sun -tight. ENVIRONMENTAL FACTORS REC Peak Energy Series panels are designed to protide decades of durable and stable output. Operating temperatures should be between -44 and 185'F (-40 and +85°C. The panels are not suitable for installation in potentially hazardous locations nor should they be installed in the following locations: • Near sources of nammable gases or vapors • Near open flames. • Underwater or in water features. • Where exposed to sulfur e.g. near sulfur springs or volcanoes. • Where the panels may be exposed to harmful chemicals. Ensure panels are not exposed to direct contact with saltwater/spray and avoid installatton in areas subject to high salt rim content ea& coastal areas. PANEL HANDLING Panels should be handled with care. All warnings and instructions on the packaging should be observed. Follow these guidelines when unpacking transporting or storing the panels. • Record the serial numbers prior to installation and note the Information in the system documentation. • Carry the panels using both hands and avoid usingthe junction box as a grip.. • Do not allow the panels to sag or bow under their own weight when being carried. • Do not subject the panels to loads or stresses e.g., leaning or placing heavy abjectsonthem. • Do not stand on the panels or cause impact through droppingthenn. • Keep all electrical contacts clean and dry. • Store panels in a dry and properly ventilated room • Do not apply force to the backsheet. • Avoid using sharp or pointed objects if panels require marking. • Never apply paints, adhesives or detergents to the back of the laminate. • Do not use any solar panel that is damaged or been tampered with. • Never attempt to disassemble the panels. A\ If the panel front glass is broken or laminate back street is damaged, it can expose personnel to hazardous voltages. At4�Misg�-�:ietd3u-�l��i1 �J3 Series 100 UL Roof Mounted System Safety Guidance - Always wear the proper OSHA approved safety equipment when working on a roof . - Safety equipment should be checked annually for wear and quality. - Always wear proper eye protection. - When walking on the roof avoid walking on installed rails. If this is unavoidable ch( L -feet for fatigue before final installation. - Appropriate fall protection gear should be used. Extreme caution should be used when near the edge of the roof. Notes - The UL Listing covers bonding for a load rating up to 45 - Series 100 UL has been tested with the following UL Listed modules: See Appendix on page 40. - These systems have been evaluated for module to systam bonding, only to the requirements of UL Subject 2703. - This system has also been evaluated for a Class A System Classification for a steep -sloped roof with Type 1 modules. 1219W14 QIMS.E359313 - Mounting Systems, Mounting Devices, Claming Devices and Graz -d Lugs for Usewith Photcvataic ModUes and Panels QIMS.E359313 Mounting Systems, Mounting Devices, Clamping Devices and Ground Lugs for Use with Photovoltaic Modules and Panels Page Bottom Mounting Systems, Mounting Devices, Clamping Devices and Ground Lugs for Use with Photovoltaic Modules and Panels P General Informc-ition for Mounting 5ystems Mounting Devices CiamAing Devices and Ground Lugs for Use with Photovoitaic_Nhmd es and Panels SUNRUN SOUTH LLC, DBA SNAPNRACK 775 Fiero Ln Suite 200 San Luis Obispo, CA 93401 USA E359313 Investigated Investigated for System Fire Cat, for Mechanical Classification No. Bonding Loading (A, B or C) Tested in Combination With Photovoltaic mounting system Series Y N - UL Listed PV Modules: 350 PEC Solar AS: REC214, REC215, REC220, REC225, REC2.30, PEC235, REC240, RE -C245, REC250, REC255, REC260, RL -C265•, PEC270, all followed by PE, PE(BLK), PC -US, PE-US(BLK), PE Q2 or PEQ3. I Hyundai heavy Industries Co Ltd: HiS-MxxxMG Series - taiS-Mi210MG, HiS-61213MG, MS-M215MG, MS-M21814G, HiS-M22014G, HiS-M22314G, HiS-M225MG, FPS- M228MG, HiS-M230MG, HiS-M233MG, HiS-1423514G, HIS41238MG, •HiS-M24OMG, HiS-M243MG, HIS-14245MG, HiS-MNWIG, 1-tiS- M25OMG, HiS-14253MG, MS-M25514G, HiS-M258MG, WS-M260MG, His-M263MG, HiS-M265MG, HiS-101268MG, His-M27O14G, HiS-SxxYMG Senes - HiS-S220MG, HIS-S2231AG, HiS-S225MG, HIS-S226MG, hl.iS-S2301AG, HiS-S233MG, HiS-S235MG, FHS- 5238MG, HiS-S240MG, HiS-5243MG, HiS-S245MG, HiS-S24.8MG, HiS-5250MG, HiS-S253MG, HiS-S255MG, HiS-S258MG, HIS- S260MG, HiS-S263MG, HIS-5265MG, HiS-S268MG, HiS-S270MG, HiS-5273MG, FHS-S275MG; all may be followed by the suffix 8K or blank, Penesola Jiangsu Ltd: JCxxxM-24/66 Series - JC200M-24 Bb, JC205M-2416b, JC210M-24/Bb, JC215M-24/Bb, 1C220M-24,/Bb„ JC225M-24/Bb, 1C230M-2418b, 1C235M-24/13b, 1C24M-24 13b„ IC24SM-24/Bb, JC250M-24/6b, 3C255M-24/Bb, 3C-260M-241Bb„ Series Y N - JC26SM-24/5b, 1C270+24/13b. 100 Suniva Inc - MVX-235-60-5-701, MVX-240-60-5-M1, WX-24,5-613- 5-7Ci1, mvx-25D-60-5-701, MVX-255-60-5-701, M X-260-60-5-701, MVX-265-60-5-701;, 1,WX-23.5-60-5-7B1, MVX-240-60-5-781, MVX-245-60-5-781, M1VX- 250-60-5-781, IJNTX-255-60-5-7B1, MIX -260-60-5-7131, idlyfX-265- 6G-5-781; OPT -250-60-4-800, OPT 255-60-4-800, OPT -260-60-4-80'0, 017T- 265-60-4-800, OPT -27O-60-4-800, OPT -275 -60 -4 -OW; OPT -25D -60-4-8B0, OPT -255-60-4-860, OPT -26D-60-4-8130, QPT 26 r -60 -+J --SBO, OFT -270 -6D -4 -SBO, OPT -275-60-4-8W. Yingh Energy (China) Co Ltd - YLXYXP-29b Series - YL215P-29b, YL22OP-29b, YL225P-29b, YL23DP-29b, NI -235P -29b, YL240P-29b, YL245P-291), YL250P-29b, YL255P-29b, Y1260P-29b; YLXXXA-28b Series - YL22DA-29b, YL225A-29b, YL2304-29b, YL235A-29b, YL240A-29b, YL245A-29b, YL250A-29b, YL255A-29b•. I http://database.ul.com/cgi-birdXYVAemplate USE)<T/lFRAMElstoMmge.it-ni?name=QIMSE359313&ccrrohorntle=fillamfrg+Systems,+Mejrtrgg E)eOces,._.. 12 12/9/2014 QIMS.E359313 - Mounting Systems, Mounting Devices, Clamping Devices and Ground Lugs for Use with PiVovoltaic Modlutes and Parj2ls Trina Solar Ltd - TSM-215PA05, TSM-220PAD5, TSM•-225PAD5, TSM- 230PAO5, TSM-235PA05,, TSM-240PA05, TSM-245PA05, TSM•- 250PA05, TSM-255PA05, TSM-260PA05; TSM-215PA05.05, TSM-220PA05,05, TSM-225PA05.05,, TSNI 230PA05,05, TSM-235PAO5.05, TSM-24DPAD5,05, TSM-245PAO5-M TSM-250PA05.05, TSM-255PAD5.05, TSM-260PA05,05; TSM-215PA05,06, TSM-220PA05,06, TSM-225PAO5,06, TSM - Series Y N - 23DPA05.08, TSM-23SPA05,08, 7SM-240PA05,06, TSM-245PA05.08, 200 TSM-250PA05.,06, 7SM-255PA05,08, TSM-260PAD5.08- TSM-215PDO5, TSM-220PD05, TSM-225PDO5, T5M-230PDD5, TSM- 235PDD5, TSM-240PDO5, TSM-245PD05, TSM -250P005, TSM- 255PD05, TSM-260PD05; TSM-215PDO5.08, 7SM-220PDO5,06, TSM-225PIDD.5,08, TSM- 230PDO5,08, TSM-235PDO5.08, TSM-240PDO5.08, 7, SM-245PDG548, TSM-250PD05,08, TSM-255PD05,08, TSM-260PDO5.08. NRTL Lasted PV Modules: Hanwha SolarOne: Models HSL60P6-PI3-2-230Q, HSL60P6-P8-2- 235Q, HSLGOP6-PB-2-240Q, I1SL60P6-PB-2-245Q, HSL60P6-PB-2- 250Q, HSL6OP6-PB-2-255Q, HSL60P6-PB-2-260Q, HSL6DP6-PB-2- 265Q, HSL6OP6-PB-2-270Q; HSL60P6-PB-4-23DQ, HSL6OP6-PB-4-235Q, HSL60P6-PB-4-240Q, HSL6GP6-PB-4-245Q, HSL60P6-PB-4-250Q, 41SL60P6-PB-4-2550, HSL6OP6-PB-4-260Q, HSL60P6-PB-4-265Q, HSL60P6-PB-4-270Q; may be followed by additional suffixes. Suniva Inc - OPTXXX-60-4-y'Y V; where XXX may be numbers 240 to 270 in increments of 5; where YYY may be 100; OPTXXX-6O-4-YYY; where XXX may be numbers 235 to 265 in increments of 5; where YYY may be 180. Ser es ry N N A Type 1 PV Modules Trademark and/cr Tradename: "SNAPNRACK' Last Updated on 2014-08-26 Questions? Print this pace Terms of Use Pooe Top Chi 2014 UI_ LLC When the UL Leaf Mark, is on the product, or when the word "Environment" is included in the U1. Mark, please Beard).. the QL Environment database for additional information regarding this product's certification. The appearance of a company's name or product In this database does not in itself assure that products so identified have been manufartured under UL's Follow -Up Service. Only those products bearing the UL Marie should be considered to be Certified and covered under UL's Follow -Up Service, Always look for the Mark on the product. UL pen -nits the reproduction of the material contained in the Online Certification Directory subject to the following conditions- 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications Zfles) must be presented in their entirety and in a non - misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Ceryl icatims; Director. with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "t7c 2014 UL LLC". http://database.ul.corn/cgi-UnXWAemplate/USEXTIIFRAMElshmvpagehiml?name=OiM&E,5MI39ccnshorttffe=Mmrfj g+Systems,+Mour6 f3eWom.._.. .292 solar=se SolarEdge Single Phase Inverters For North America SE3000A-US / SE380OA-US / SE5000A-US / SE6000A-US / SE760OA-US / SE10000A-US / SE1140OA-US \everter , 25 1 VeV5 Wacrant`1 0 wll� e APMM The best choice for SolarEdge enabled systems Integrated arc fault protection (Type 1) for NEC 2011690.11 compliance Superior efficiency (98%) Small, lightweight and easy to install on provided bracket Built-in module -level monitoring Internet connection through Ethernet or Wireless Outdoor and indoor installation Fixed voltage inverter, DC/AC conversion only Pre -assembled Safety Switch for faster installation Optional — revenue grade data, ANSI C12.1 USA- GERMANY -ITALY -FRANCE -JAPAN -CHINA -AUSTRALIA -THE NETHERLANDS -ISRAEL www.solaredge.us solar =es z Single Phase Inverters for North America SE3000A-US/ SE380OA-US/ SE500OA-US/ SE6000A-US/ SE760OA-US / SE1000OA-US / SE1140OA-US OUTPUT Nominal AC Power Output ..... .................................. Max. AC Power Output *AC Output Voltage* ,Min: *Nom: * *M* *a*x'.i 'Y 183 - 208 - 229 Vac ........................................ AC Output Voltage Min :Nom.-Max.4) .211 . 210 -2 . 64 . Vac .................... AC Fre ..qyMg Min.-Nom.-Max.(Ii ...................... Max. Continuous Output Current 461 Threshold ........................................ SE3000A-US I SE31300A-US I SE5000A-US _SE6000A-US . SE760OA-US SE10000A- US SE1140OA-US Recommended Max. DC Power"' 3750 4750 6250 7500 9500 12400 9980 @ 208V 3000 3800 .... .... 5000 . 6 000 7600 ................ . 10000 Q)�!Qy .... ..... . . . ...... -less, Ungrounded ................... ... *.***..- *.."-..-.. 5400 @ 208V M ............. ..................... .. .... i6i&@ 208V. 3300 4150 .... . ...' '' 325 @ 208V 350 @ 240V.......................... 54506000 ... ..... I 8350 ,10950 .Q)240V Y6.96i68V I8 23 33 @ 208V 3 45 Adc ..................1......9.5......1......13...... . .. ................ V .............. .....I...................................... V V .. ..*.. Max.input Short Circuit Current ..-.. 45 ... ...... ...... ...... 59.3: 60 :60.5 (with ..... ....... ....... ......... .H I country �9.- ...... . ......... 60.51 ....... ..... ..... ...... 1"**** 12.5 . . * 16* 'IV 1.......... 2..5 3..2 ..... .............. ...2A.e. �49Y .. ....... ...... . �Qy ..?4.0..V. .. 97.5 ... .......... 97.5 I ..... ................ 9 7. 5 ................. ................ ................. ..... ............... ...... I ....... .......... , Country ConfiRurable Thresholds Yes 4 Recommended Max. DC Power"' 3750 4750 6250 7500 9500 12400 14250 W AN) .................................. .... ........ ........ .... ............ . . . ...... -less, Ungrounded ................... ... *.***..- *.."-..-.. ........................................­­..... .... ...... M ............. ..................... .. .... ..­.... ...................... ..... ............ ...... .. ........... ..... ...................I.... R. .............................. ...............'5 .0 .. .Transformer dc Nom. DC Input Vofta�e................ .......'*.......* . ...' '' 325 @ 208V 350 @ 240V.......................... ... ..... Max. Input Current"' Y6.96i68V I8 23 33 @ 208V 3 45 Adc ..................1......9.5......1......13...... . .. .15.5 & V 30.5e.?4Qy .. ..*.. Max.input Short Circuit Current ..-.. 45 ... Adc. iev erse-Polarl ty P rot ectionYes Reverse Polarl. ............. .............. ................ ....... ............... .... ..... Ground -Fault Isolation Detection (. .. 6001. Sensitivity . Maximum Inverter Efficiency.......... 97.7.....1.....98.2.....1:.....98.3......1.....98.3 CEC Weighted Efficiency ............... 97.5 98 .............. ..?4.0..V. .. 97.5 ... .......... 97.5 ..97.5 . 9 7. 5 ................. % Nighttime Power Consumption < 25 4 ADDITIONAL FEATURES Supported Communication Interfaces - ................. RS485, RS232, Ethernet, ZigBee (optional) '6pti,ona'111), ... ........... Revenue Grade Data, ANSI C12.1 .... .... . ....... .. .. ... Rapid i� utdo . w . n - NEC . 20 . 14 . 690 . . .12 . ............... ................ ................ ................. ............... ..... F.u.nctio-nality-enabled -when SolarEdge rapid shutdown kit is installed(') ... STANDARD COMPLIANCE Safety.......................... ....... ....... I . ....... YL1741, UL1699B, U1.1998, CSA 22.2 ........ ................ ................ ................. ................. Grid Connection Standards ... - ............... . .......... ........ Emission;--- FCC part15 class B INSTALLATION SPECIFICATIONS AC output conduit size /AWG range *C'0*n*d-uit *st'r*i*n* .... .. 3/4".rni.n.imum./.16-6.AWG .. ................ ............. 3/4"Min.imu.m./.8-3 AWG ............ .... .. .......... size /"#"o*f* '66n, input strings 1 3/4" minimum 1 -2 strings 16-6 AWG 3/4" minimum 1-2 strings 14-6 AWG AWG ran e Dimensions with Safety Switch 30.5 x 12.5 x 7/ 30.5 x 12.5 x 7.5 30.5 x 12.5 x 10.5 775 x 315 x 260 Mr?) 775 x 315 x 172 775 x 315 x 191 ........... ..... I ........... mm .......... .W.............................. ............... Weight with Safety .............. 51.2/23.2 ......... ................ ................ .......... 54.7/24.7 88.4/40.1 lb/k ....... ...............................Cooling . ...... Natural Convection ..... .... Fans (user replaceable) Noise ­ra dBA Min: Max. Operating Temperature 13 to +140 -25 to +60 40 to +60 version available ) F C ................................. Protection Rating ............. ..... I ........... .................Ui .......... For other regional settings please contact SolarEdge support. (2) 6kW and lower: Limited to135% of AC power; 7.6kW and higher: Limited to 125% for locations where the yearly average high temperature is above 77'F/25'C and to 135% for locations where it is below 77'F/25"C. For detailed information, refer to I Isl A higher current source may be used; the inverter will limit Its input current to the values stated. It) Revenue grade inverter P/N: 5ExxxxA-US000NNR2 1`1 Rapid shutdown kit P/N: SE1000-110-SI 161-40 version P/N: SExxxxA-1.150001SINLI4 Page 1/2 L'RmRted Warranty Cera rata for REC Peak Energy SaKess kladuks & REC Peak Energy �ntegratad oddees' (valid as of Septemberl, 2011) This Limited Warranty is valid only in North America, Central America and South American and for all REC ProductsS(-as defined above) sold after Septemberl, 2011 or later. REC MODULES PTE. LTD. (hereafter the'Warrantor' or'REC') issues the following voluntary warranty to the end-user who qurchased the Proz1actin orre of the above rrae,nt;wraed c=tries and_pr.t t, e Pru.duct Wo use for t,'- 5rst tdr,7e k+.�e'Crigv.al End -User'). In addition to the rights under this Limited Warranty, the Original End -User maybe entitled to statutory warranty rights under applicable national laws which shall not be affected or limited in anyway by this Limited Warranty. L Product Warranty Subject to the terms and conditions of this Limited Warranty, REC warrants that the Products: • Are -free from defects in material and workmanship for a period of 10 years from the date of purchase by -the Original End -User (not exceeding a maximum period of 10.5 years from the date of production as identified on the Product) (the 'Warranty Period') if installed and used in accordance with the installation instructions available to download fRom www. recgroup.com. Will remain.safe and operational if cable and connector plugs are installed professionally and are not permanently positioned in water; provided however, that damage to the cable caused by abrasion on a rough surface due to insufficient fixing or to unprotected running of the cable over sharp edges is excluded. Damage caused by anim als is also excluded. LL Will not experience freezing up of the aluminum frames if installed correctly. The outer appearance of the Product, including scratches, stains, rust, mould, discoloration and other signs of normal wear and tear, which occurred after delivery or installation, do not constitute defects, provided the functionality of the Rroduct is not affected. Glass breakage constitutes a defect only if not caused by any external influence. If a defect occurs during the Warranty Period affecting the functionality of the Product, REC will, at its sole option: Repair -the defective Product. Replace the Product with an equivalent product. Refund the current market price of an equivalent product at the time of the claim. Ullo t¢'ower Output Warranty Subject to the terms and conditions of this Limited`Warranty, REC warrants that the actual power output of the Product will reach at least 97% of the nameplate power out specified on the Product during the first year (calculated from the date of production as identified on the Product). From the second year, the actual power output will decline annually by no more than 0.7% for a period of 24 years, so that by the end of the 25th year, an actual output of at least 00.2% of the nameplate power out specified on the Product will be achieved. TMs Power Output, Warranty covers only reduced performance due to natuurai degvadatfi®¢t of the glass, the the ernIbeddling fall, qhe fuwctilon bon and sunder warmall use. If the Product does not reach the warranted power output levels set out above when measured by the Warrantor or by an independent measuring institute agreed to prior to testing by the Warrantor, under standard test conditions (IEC 61215) and taking into accour>t a ±3% tolerance range, then REC will, at its sole option: Repairthe Product Replace the Product with an equivalent product or to supply additional modules as necessary to achieve the warranted percentage of specified power output. Refund the current market price of an equivalent product at the time of the claim 1 excluding madulesshowing"Q3"aspart,ofthe product name. z Defined as,atl member states of the Organization of American States, OAS. Rev. G.1, September 2011 This warranty is only applicable in the member states of the Organization of American States, OAS Page 2/2 111111. Warranty Canditaanso L, m Rattans and EEKd us6anz 1. This LimitedWarranty is not transferable by the Original End -User, except to a subsequent owner of the solar {rower facility at which the Product was originally installed and remains installed, provided that this solar power faci[i; y has not been alteredtin any way ormoved from the structure or property at which it was originally installed. 2. Notification of a warrantyclaim hereunder must be given without undue delay after detection of the defect arrd priorto the expiration of the applicable Warranty Period and in accordance with the procedure as set out in section IV below. 3. Rease note that thils L, mated Warranty/ does not cover nor wM the Warrantor retro burse, any an -sate Ilafbor (or other costs ancuurred iin connection with the cr rem ovall of defactave Pr®dluust transp art mgr ahe re- linstappata®n of replaced or repaired Products or any/ components. 4. The Warrantor may use remanufactured or refurbished parts or products when repairing or replacing any Products under this Limited Warranty. Any exchanged or replaced parts or Products will become the property of REC. The Warranty Periods set out in sections I. and 11. dbove will not be extended in any way in the event of a replacement or repair of a Product. 5. This Limited Warranty requires that the Product is installed according to the latest safety, installation and operation instructions provided by REC and does not apply to damage, malfunction, power output or service failures whidh have been caused by: (a) repair, modifications or removal of the Product by someone otherthan a qualified.service technician,• (b) any improper attachment, installation or application of the Product or (c) abuse, misuse, accident, negligent acts, power failures or surges, lightning, fire, flood, accidental breakage, actions of third parties and other events or;accidents outside REC's reasonable control and/or not arising under normal operating conditions. 6. This Limited Warranty is provided voluntarily and free of charge and does not constitute an independent guaraintee promise. -Therefore, ifany defect materiallyaffectsthefunctionality of the Product or -results inapoweroutpwtbelow - the warranted levels, the Original End -User's remedies are limited exclusively to the remedies set out under serctions I. and II. in the warranty cases specified herein. REC ASSUMES RD WARRARMES, EXPRESS OR IMPLlE®p OTHER THAN THE WARRARTIIEES MADE HERElM AVS® SPEO FICAL LY DIISCLAIIMS ALL 07H ER WARRANTIES, MERCHARTABI Ll7 Y OR PIITMESS FOR A PARTpCU(LAR PURPOSE. REC EXCLUDES ALL [LIIAML OTLEES FOR ANY SP'EEClAL, IINC[IDE DTiAL, CONSEQUENTIAL OR PURlTME DAMAGES FROM TIBC USE OR LOSS OF USE OF THE PRODUCTS TO PERFORM AS WARRAN'TE®p 11MCILUDIING BUT MOT LIMITED TO DAMAGES FOR LOSS OF POWER, LOST P'ROR7S OR SAVIINGS7 NOR EXPENSES ARlSl G FROM 7HORD-PART°e CL,AgMiS. This does not apply to the extent the Warrantor is liable under applicable mandatory product liability laws or in cases of intent or gross negligence on the part of the Warrantor. J. This Limited Warranty shall be governed by and construed in accordance with the laws of the State of CaliforniEa without giving effect to its conflict of laws provisions. The United Nations Convention on Contracts for the International Sale of Goods (1900) shall not apply to or govern this Limited Warranty or any aspect of any dispute arising there from. kl.V Warranty call oo Procedure Claims under:this:Limited Warranty must be made by.notifying the authorized distributor or seller where the Product was first purchased. A claim may be registered at: www.recgroup.com/warranty For Warranty Claim to be processed, proof of the original purchase of the Product and any subsequent sales including transfer of this Warranty need to accompany the claim. The claim must include a description of the alleged defect(s) as well as the Product's serial number(s). Prior to returning any Products or components to REC, an RMA (Return Merchandise Authorization) number is required, which may be obtained by contacting REC via the aforesaid address. This warranty is valid for Products sold on or after September 1, 2011. Sangapore' Ca)09.2©11i pv�v�v�.,a„ev�ve ao 0o ao 00 00 00 This warranty is only applicable in the member states of the Organization of American States, OAS Rev. G.1, September 2011 m SNAPNRACK COMPOSITION L FOOT CAN BE MOUNTED IN ANY ORIENTATION SNAPNRACK CHAIrn NUT SNAPNRACK STANDARD RAIL SNAPNRACK COMPOSITION ROOF FLASHING A' S.S. LAG SCREV WITH FLAT VASHER 2.5' MINIMUM EMBEDMENT IS STANDARD SNAPNRACK L FOOT BASE SEAL PENETRATION AND UNDER BASE WITH APPROPRIATE ROOF SEALANT RAFTER TYP. A X V S.S. BOLT AND SPLIT WASHER - A S.S. FLANGE NUT ROOF DECKING TYP. FLASHED L FOOT MOUNTING POINT FOR USE ON COMPOSITION ROOF" SURFACES WITH LOW TO MODERATE TILT RAILS CAN BE LEVELED UP TO 3' USING UP TU TWO LEVELING SPACERS AS SHOVH IN 'SERIES 100 RAIL LEVELING' G.MCPHEETERS ISCAIE I DNS PART G. MCPHEETERS DATE 1zo111 PEN-DO1 �«v N NOTES- - - a - 5/16' LAG BOLTS MUST EMBED ---- Z 2S' INTO ROOF STRUCTURAL MEMBERS/RAFTERS - TORGUE ALL 5/16' HARDVARE TO [1 THE FULLOVING X - SILVER S.S. 10-16 FT -LBS 3 - BLACK S.S. 7-9 FT -LBS !n - RAILS CAN MOM TO EITHER SIDE m OF L FUOT (UPSLOPE VS DOVNSLOPE) Z) m to J STEP 3, PLACE L FOOT ON TOP o OF FLASHING AND TIGHTEN NOT o STEP 2, SLIP O FLASHING OVER O L FOOT BASE _n STEP D BOLT L FOOT BASE TO ROOF WITH O LAG BOLT C Z D r r D -I O ROOF DECKING TYP. Z Z C D 1�S�PL�ATI�N r CD��EjED PEN DETAIL 01 FLASHED L, FOOT I�" E HIGH PERFORMANCE SOLAR PANELS REC PEC �. E f � E RS Y�,,��, Dow"I �JLWMFPWTi4 uvuE t;Om Li/AN ��owreci 'ray Creak Energy tenes panels dre the perfect choice for building solar systems that combine long lasting product quality µ with reliable po'Ner output. REC combines leading standards of design and manufacturing P high- performance produce hi h- performance solar panels with uncompromising quality. •:moo«:''o REC PEAK ENERGY SERIES 991-81 T T -- -- --- - - - 8 - -- - -- - -- ----- •D' Nominal Power- P pp(Wp) ' EFFIOENCY A 27.7 28.1 28.3 28.5 29A 29-4 ! 6.58 6.64 6-68 6-77 6.81 6-90 Open Circuit Voltage-Voc V) 34.4 34.7 35.0 353 35-7 36.0 Short Circuit Current - Isc(A) I 7.08 7.12 7.21 7-24 7.30 Nominal operating cell temperature NOCT YEAR PRODUCT WARRANT 1.5, windspeedI m/s, ambient temperature 20`4 E YEAR LINEAR POWER OUTPUT WARRANT`( US IMPORT DUTY FREE 9A3 F Mounting holes TEMPERATURE RATINGSf + t i Nominal Operating Cell Temperature(NOCT) 45.7°C(;2`C) Temperature Coefficient of P,,, -0.40%/'C 177 Temperature Coefficient of Vx -0.27 %/'C 4 Temperature Coefficient of 1, 0-024%/'C All measurements in inches ELECTRICAL DATA@ STC REC240PE•• OGENERALDATA Nominal Power- P,,,, (Wp) 240 245 250 255 .260 265 Cell Type: 60 REC PEmulti-crystalline Watt Class Sorting -(W) 0/+5 0/+5 0/+5 0/+5 01+5 01+5 3 strings of 20 cells with bypass diodes Nominal Power Voltage V,,,, (V) 29.7 30.1 30.2 305 30.7 30.9 Glass: 1/8'mmsolarglasswith anti -reflection surface treatment Nominal Power Current-ImpP(A) 8,17 8.23 830 8.42 850 8.58 Back Sheet: Double layer highly resistant polyester Open Circuit Voltage-Voc(V) 36.8 37.1 37.4 37.6 37.8 3&1 Frame: Anodized aluminum (silver) Short Circuit Current -Isr(A) 8.7S 8.80 8.86 8.95 9.01 9.0B )unction Box: IP67rated Panel Efficiency (°.U) 14.5 14.8 15.1 155 15..8 16_1 4 mm2 solar cable, 35'+47' Connectors: Multi-ContactNIC4(4mm2) Analysed data demonstrates that 99.7%of panels produced have current and voltage tolerance of±-_-%fmrn rm-mrtail vahw-5 Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W/m2, cell temperature 25`14 Origin: Made in Singapore At low irradiance of 200 W/m2 (AM'1.5 and cell temperature 25'C) at least 96%°f the STC parcel of%riency vrill be achieved. ELECTRICAL DATA@ NOCT REC240PE0' •D' Nominal Power- P pp(Wp) 183 187 189 193 197 202 Nominal Power Voltage - V,,,, (V) 27.7 28.1 28.3 28.5 29A 29-4 Nominal Power Current -I,p(A) 6.58 6.64 6-68 6-77 6.81 6-90 Open Circuit Voltage-Voc V) 34.4 34.7 35.0 353 35-7 36.0 Short Circuit Current - Isc(A) 7.03 7.08 7.12 7.21 7-24 7.30 Nominal operating cell temperature NOCT (800 W/m2, AM 1.5, windspeedI m/s, ambient temperature 20`4 MAXIMLIMRATINGS Operational Temperature: -40...+85'C Maximum System Voltage: 600V Design Load': 75.21bs/ft2 (3600 Pa) Max Series Fuse Rating: Max Reverse Current: 33.4 lbs/ft2 (1600 Pa) Refer to installation maaral 15 A 15A CERTIFICATION C� � 10 year pro linear owero ty. Dimensions: 65'/2x39xlU2in �L us 25 year linear power output warranty Area: 17314ft2 LISTED (max. degression in performance of G3% p.a i, IEC61215,IEC6]730&- 1703:IEC62716(Ammnnia Weight: 391/2 lbs Resistance) IEC 61701 (Salt Mist- severity levels 1 & 61 Note! All given specifications are subject to change IEC 60068-2-68 (Slowing Sand) without notice atany time. REC isaleadingglobalprovider ofsolar energy solutions. With more than 15 years ofexpertence>weofiersurstainable,high performifq products, services and investments for the solar industry. Together with our pal -triers, we create value by providing solutions that REC better meet the world's growing energy needs. RE C is headquartered in Norway and listed on the Oslo Stock Exchange (ticker: RECS0Q_ Our 1,600 employees worldwide generated revenues of USD 647million in 2013_ ymwxecgmptam MECHANICAL INSTALLATION FIRE GUIDELINES REC Peak Energy Series aanels gave a Class C, Type I F re class;fication. The fire rating of this panel is only valid when mounted in the manner specii6ed in these mechanical mounting instructions. Utilize the following fire safety guidelines when installing REC Peak Energy Series panels: • Check with local authorities for fire safety guidelines and requirements for any building or structure onto which the panets Will be instailled.. • The system design should ensure that it can be easily accessed in ttae event of a building fire. • Check with local authorities for applicable regulations concerning setbacks of other placement restrictions that rnay apply for roof- mounted arrays.. • The use of DC ground fault interrupters is recommended. This may also be required by local and national codes. • All electrical appliances are a fire risk. The panel should therefore be mounted over a fire retardant roof covering rated forthe applicaiion and' a suitable distance of 4 in between the panel and the rnountingsurface, allowingfree Circulation of air beneath the panels., should be respected at all times. ORIENTATION To maximize system output, panels should be installed at the optimum orientation and tilt angle. The specifics of this depend an location and can he calculated by a qualified system designer. A lower angle of panel installation increases the requirement for regular cleaning. The optimal mounting position of panels results in the sun's rays falling perpendicular (i.e. at 90") to the surface. All panels in a string should, wherever possible, have the same orientation and tilt to ensure the system does not underperform due to mismatched outputs. 1 The panels must not be exposed to artificially concentrated sun -tight. ENVIRONMENTAL FACTORS REC Peak Energy Series panels are designed to protide decades of durable and stable output. Operating temperatures should be between -44 and 185'F (-40 and +85°C. The panels are not suitable for installation in potentially hazardous locations nor should they be installed in the following locations: • Near sources of nammable gases or vapors • Near open flames. • Underwater or in water features. • Where exposed to sulfur e.g. near sulfur springs or volcanoes. • Where the panels may be exposed to harmful chemicals. Ensure panels are not exposed to direct contact with saltwater/spray and avoid installatton in areas subject to high salt rim content ea& coastal areas. PANEL HANDLING Panels should be handled with care. All warnings and instructions on the packaging should be observed. Follow these guidelines when unpacking transporting or storing the panels. • Record the serial numbers prior to installation and note the Information in the system documentation. • Carry the panels using both hands and avoid usingthe junction box as a grip.. • Do not allow the panels to sag or bow under their own weight when being carried. • Do not subject the panels to loads or stresses e.g., leaning or placing heavy abjectsonthem. • Do not stand on the panels or cause impact through droppingthenn. • Keep all electrical contacts clean and dry. • Store panels in a dry and properly ventilated room • Do not apply force to the backsheet. • Avoid using sharp or pointed objects if panels require marking. • Never apply paints, adhesives or detergents to the back of the laminate. • Do not use any solar panel that is damaged or been tampered with. • Never attempt to disassemble the panels. A\ If the panel front glass is broken or laminate back street is damaged, it can expose personnel to hazardous voltages. At4�Misg�-�:ietd3u-�l��i1 �J3 Series 100 UL Roof Mounted System Safety Guidance - Always wear the proper OSHA approved safety equipment when working on a roof . - Safety equipment should be checked annually for wear and quality. - Always wear proper eye protection. - When walking on the roof avoid walking on installed rails. If this is unavoidable ch( L -feet for fatigue before final installation. - Appropriate fall protection gear should be used. Extreme caution should be used when near the edge of the roof. Notes - The UL Listing covers bonding for a load rating up to 45 - Series 100 UL has been tested with the following UL Listed modules: See Appendix on page 40. - These systems have been evaluated for module to systam bonding, only to the requirements of UL Subject 2703. - This system has also been evaluated for a Class A System Classification for a steep -sloped roof with Type 1 modules. 1219W14 QIMS.E359313 - Mounting Systems, Mounting Devices, Claming Devices and Graz -d Lugs for Usewith Photcvataic ModUes and Panels QIMS.E359313 Mounting Systems, Mounting Devices, Clamping Devices and Ground Lugs for Use with Photovoltaic Modules and Panels Page Bottom Mounting Systems, Mounting Devices, Clamping Devices and Ground Lugs for Use with Photovoltaic Modules and Panels P General Informc-ition for Mounting 5ystems Mounting Devices CiamAing Devices and Ground Lugs for Use with Photovoitaic_Nhmd es and Panels SUNRUN SOUTH LLC, DBA SNAPNRACK 775 Fiero Ln Suite 200 San Luis Obispo, CA 93401 USA E359313 Investigated Investigated for System Fire Cat, for Mechanical Classification No. Bonding Loading (A, B or C) Tested in Combination With Photovoltaic mounting system Series Y N - UL Listed PV Modules: 350 PEC Solar AS: REC214, REC215, REC220, REC225, REC2.30, PEC235, REC240, RE -C245, REC250, REC255, REC260, RL -C265•, PEC270, all followed by PE, PE(BLK), PC -US, PE-US(BLK), PE Q2 or PEQ3. I Hyundai heavy Industries Co Ltd: HiS-MxxxMG Series - taiS-Mi210MG, HiS-61213MG, MS-M215MG, MS-M21814G, HiS-M22014G, HiS-M22314G, HiS-M225MG, FPS- M228MG, HiS-M230MG, HiS-M233MG, HiS-1423514G, HIS41238MG, •HiS-M24OMG, HiS-M243MG, HIS-14245MG, HiS-MNWIG, 1-tiS- M25OMG, HiS-14253MG, MS-M25514G, HiS-M258MG, WS-M260MG, His-M263MG, HiS-M265MG, HiS-101268MG, His-M27O14G, HiS-SxxYMG Senes - HiS-S220MG, HIS-S2231AG, HiS-S225MG, HIS-S226MG, hl.iS-S2301AG, HiS-S233MG, HiS-S235MG, FHS- 5238MG, HiS-S240MG, HiS-5243MG, HiS-S245MG, HiS-S24.8MG, HiS-5250MG, HiS-S253MG, HiS-S255MG, HiS-S258MG, HIS- S260MG, HiS-S263MG, HIS-5265MG, HiS-S268MG, HiS-S270MG, HiS-5273MG, FHS-S275MG; all may be followed by the suffix 8K or blank, Penesola Jiangsu Ltd: JCxxxM-24/66 Series - JC200M-24 Bb, JC205M-2416b, JC210M-24/Bb, JC215M-24/Bb, 1C220M-24,/Bb„ JC225M-24/Bb, 1C230M-2418b, 1C235M-24/13b, 1C24M-24 13b„ IC24SM-24/Bb, JC250M-24/6b, 3C255M-24/Bb, 3C-260M-241Bb„ Series Y N - JC26SM-24/5b, 1C270+24/13b. 100 Suniva Inc - MVX-235-60-5-701, MVX-240-60-5-M1, WX-24,5-613- 5-7Ci1, mvx-25D-60-5-701, MVX-255-60-5-701, M X-260-60-5-701, MVX-265-60-5-701;, 1,WX-23.5-60-5-7B1, MVX-240-60-5-781, MVX-245-60-5-781, M1VX- 250-60-5-781, IJNTX-255-60-5-7B1, MIX -260-60-5-7131, idlyfX-265- 6G-5-781; OPT -250-60-4-800, OPT 255-60-4-800, OPT -260-60-4-80'0, 017T- 265-60-4-800, OPT -27O-60-4-800, OPT -275 -60 -4 -OW; OPT -25D -60-4-8B0, OPT -255-60-4-860, OPT -26D-60-4-8130, QPT 26 r -60 -+J --SBO, OFT -270 -6D -4 -SBO, OPT -275-60-4-8W. Yingh Energy (China) Co Ltd - YLXYXP-29b Series - YL215P-29b, YL22OP-29b, YL225P-29b, YL23DP-29b, NI -235P -29b, YL240P-29b, YL245P-291), YL250P-29b, YL255P-29b, Y1260P-29b; YLXXXA-28b Series - YL22DA-29b, YL225A-29b, YL2304-29b, YL235A-29b, YL240A-29b, YL245A-29b, YL250A-29b, YL255A-29b•. I http://database.ul.com/cgi-birdXYVAemplate USE)<T/lFRAMElstoMmge.it-ni?name=QIMSE359313&ccrrohorntle=fillamfrg+Systems,+Mejrtrgg E)eOces,._.. 12 12/9/2014 QIMS.E359313 - Mounting Systems, Mounting Devices, Clamping Devices and Ground Lugs for Use with PiVovoltaic Modlutes and Parj2ls Trina Solar Ltd - TSM-215PA05, TSM-220PAD5, TSM•-225PAD5, TSM- 230PAO5, TSM-235PA05,, TSM-240PA05, TSM-245PA05, TSM•- 250PA05, TSM-255PA05, TSM-260PA05; TSM-215PA05.05, TSM-220PA05,05, TSM-225PA05.05,, TSNI 230PA05,05, TSM-235PAO5.05, TSM-24DPAD5,05, TSM-245PAO5-M TSM-250PA05.05, TSM-255PAD5.05, TSM-260PA05,05; TSM-215PA05,06, TSM-220PA05,06, TSM-225PAO5,06, TSM - Series Y N - 23DPA05.08, TSM-23SPA05,08, 7SM-240PA05,06, TSM-245PA05.08, 200 TSM-250PA05.,06, 7SM-255PA05,08, TSM-260PAD5.08- TSM-215PDO5, TSM-220PD05, TSM-225PDO5, T5M-230PDD5, TSM- 235PDD5, TSM-240PDO5, TSM-245PD05, TSM -250P005, TSM- 255PD05, TSM-260PD05; TSM-215PDO5.08, 7SM-220PDO5,06, TSM-225PIDD.5,08, TSM- 230PDO5,08, TSM-235PDO5.08, TSM-240PDO5.08, 7, SM-245PDG548, TSM-250PD05,08, TSM-255PD05,08, TSM-260PDO5.08. NRTL Lasted PV Modules: Hanwha SolarOne: Models HSL60P6-PI3-2-230Q, HSL60P6-P8-2- 235Q, HSLGOP6-PB-2-240Q, I1SL60P6-PB-2-245Q, HSL60P6-PB-2- 250Q, HSL6OP6-PB-2-255Q, HSL60P6-PB-2-260Q, HSL6DP6-PB-2- 265Q, HSL6OP6-PB-2-270Q; HSL60P6-PB-4-23DQ, HSL6OP6-PB-4-235Q, HSL60P6-PB-4-240Q, HSL6GP6-PB-4-245Q, HSL60P6-PB-4-250Q, 41SL60P6-PB-4-2550, HSL6OP6-PB-4-260Q, HSL60P6-PB-4-265Q, HSL60P6-PB-4-270Q; may be followed by additional suffixes. Suniva Inc - OPTXXX-60-4-y'Y V; where XXX may be numbers 240 to 270 in increments of 5; where YYY may be 100; OPTXXX-6O-4-YYY; where XXX may be numbers 235 to 265 in increments of 5; where YYY may be 180. Ser es ry N N A Type 1 PV Modules Trademark and/cr Tradename: "SNAPNRACK' Last Updated on 2014-08-26 Questions? Print this pace Terms of Use Pooe Top Chi 2014 UI_ LLC When the UL Leaf Mark, is on the product, or when the word "Environment" is included in the U1. Mark, please Beard).. the QL Environment database for additional information regarding this product's certification. The appearance of a company's name or product In this database does not in itself assure that products so identified have been manufartured under UL's Follow -Up Service. Only those products bearing the UL Marie should be considered to be Certified and covered under UL's Follow -Up Service, Always look for the Mark on the product. UL pen -nits the reproduction of the material contained in the Online Certification Directory subject to the following conditions- 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications Zfles) must be presented in their entirety and in a non - misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Ceryl icatims; Director. with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "t7c 2014 UL LLC". http://database.ul.corn/cgi-UnXWAemplate/USEXTIIFRAMElshmvpagehiml?name=OiM&E,5MI39ccnshorttffe=Mmrfj g+Systems,+Mour6 f3eWom.._.. .292 solar=se SolarEdge Single Phase Inverters For North America SE3000A-US / SE380OA-US / SE5000A-US / SE6000A-US / SE760OA-US / SE10000A-US / SE1140OA-US \everter , 25 1 VeV5 Wacrant`1 0 wll� e APMM The best choice for SolarEdge enabled systems Integrated arc fault protection (Type 1) for NEC 2011690.11 compliance Superior efficiency (98%) Small, lightweight and easy to install on provided bracket Built-in module -level monitoring Internet connection through Ethernet or Wireless Outdoor and indoor installation Fixed voltage inverter, DC/AC conversion only Pre -assembled Safety Switch for faster installation Optional — revenue grade data, ANSI C12.1 USA- GERMANY -ITALY -FRANCE -JAPAN -CHINA -AUSTRALIA -THE NETHERLANDS -ISRAEL www.solaredge.us solar =es z Single Phase Inverters for North America SE3000A-US/ SE380OA-US/ SE500OA-US/ SE6000A-US/ SE760OA-US / SE1000OA-US / SE1140OA-US OUTPUT Nominal AC Power Output ..... .................................. Max. AC Power Output *AC Output Voltage* ,Min: *Nom: * *M* *a*x'.i 'Y 183 - 208 - 229 Vac ........................................ AC Output Voltage Min :Nom.-Max.4) .211 . 210 -2 . 64 . Vac .................... AC Fre ..qyMg Min.-Nom.-Max.(Ii ...................... Max. Continuous Output Current 461 Threshold ........................................ SE3000A-US I SE31300A-US I SE5000A-US _SE6000A-US . SE760OA-US SE10000A- US SE1140OA-US Recommended Max. DC Power"' 3750 4750 6250 7500 9500 12400 9980 @ 208V 3000 3800 .... .... 5000 . 6 000 7600 ................ . 10000 Q)�!Qy .... ..... . . . ...... -less, Ungrounded ................... ... *.***..- *.."-..-.. 5400 @ 208V M ............. ..................... .. .... i6i&@ 208V. 3300 4150 .... . ...' '' 325 @ 208V 350 @ 240V.......................... 54506000 ... ..... I 8350 ,10950 .Q)240V Y6.96i68V I8 23 33 @ 208V 3 45 Adc ..................1......9.5......1......13...... . .. ................ V .............. .....I...................................... V V .. ..*.. Max.input Short Circuit Current ..-.. 45 ... ...... ...... ...... 59.3: 60 :60.5 (with ..... ....... ....... ......... .H I country �9.- ...... . ......... 60.51 ....... ..... ..... ...... 1"**** 12.5 . . * 16* 'IV 1.......... 2..5 3..2 ..... .............. ...2A.e. �49Y .. ....... ...... . �Qy ..?4.0..V. .. 97.5 ... .......... 97.5 I ..... ................ 9 7. 5 ................. ................ ................. ..... ............... ...... I ....... .......... , Country ConfiRurable Thresholds Yes 4 Recommended Max. DC Power"' 3750 4750 6250 7500 9500 12400 14250 W AN) .................................. .... ........ ........ .... ............ . . . ...... -less, Ungrounded ................... ... *.***..- *.."-..-.. ........................................­­..... .... ...... M ............. ..................... .. .... ..­.... ...................... ..... ............ ...... .. ........... ..... ...................I.... R. .............................. ...............'5 .0 .. .Transformer dc Nom. DC Input Vofta�e................ .......'*.......* . ...' '' 325 @ 208V 350 @ 240V.......................... ... ..... Max. Input Current"' Y6.96i68V I8 23 33 @ 208V 3 45 Adc ..................1......9.5......1......13...... . .. .15.5 & V 30.5e.?4Qy .. ..*.. Max.input Short Circuit Current ..-.. 45 ... Adc. iev erse-Polarl ty P rot ectionYes Reverse Polarl. ............. .............. ................ ....... ............... .... ..... Ground -Fault Isolation Detection (. .. 6001. Sensitivity . Maximum Inverter Efficiency.......... 97.7.....1.....98.2.....1:.....98.3......1.....98.3 CEC Weighted Efficiency ............... 97.5 98 .............. ..?4.0..V. .. 97.5 ... .......... 97.5 ..97.5 . 9 7. 5 ................. % Nighttime Power Consumption < 25 4 ADDITIONAL FEATURES Supported Communication Interfaces - ................. RS485, RS232, Ethernet, ZigBee (optional) '6pti,ona'111), ... ........... Revenue Grade Data, ANSI C12.1 .... .... . ....... .. .. ... Rapid i� utdo . w . n - NEC . 20 . 14 . 690 . . .12 . ............... ................ ................ ................. ............... ..... F.u.nctio-nality-enabled -when SolarEdge rapid shutdown kit is installed(') ... STANDARD COMPLIANCE Safety.......................... ....... ....... I . ....... YL1741, UL1699B, U1.1998, CSA 22.2 ........ ................ ................ ................. ................. Grid Connection Standards ... - ............... . .......... ........ Emission;--- FCC part15 class B INSTALLATION SPECIFICATIONS AC output conduit size /AWG range *C'0*n*d-uit *st'r*i*n* .... .. 3/4".rni.n.imum./.16-6.AWG .. ................ ............. 3/4"Min.imu.m./.8-3 AWG ............ .... .. .......... size /"#"o*f* '66n, input strings 1 3/4" minimum 1 -2 strings 16-6 AWG 3/4" minimum 1-2 strings 14-6 AWG AWG ran e Dimensions with Safety Switch 30.5 x 12.5 x 7/ 30.5 x 12.5 x 7.5 30.5 x 12.5 x 10.5 775 x 315 x 260 Mr?) 775 x 315 x 172 775 x 315 x 191 ........... ..... I ........... mm .......... .W.............................. ............... Weight with Safety .............. 51.2/23.2 ......... ................ ................ .......... 54.7/24.7 88.4/40.1 lb/k ....... ...............................Cooling . ...... Natural Convection ..... .... Fans (user replaceable) Noise ­ra dBA Min: Max. Operating Temperature 13 to +140 -25 to +60 40 to +60 version available ) F C ................................. Protection Rating ............. ..... I ........... .................Ui .......... For other regional settings please contact SolarEdge support. (2) 6kW and lower: Limited to135% of AC power; 7.6kW and higher: Limited to 125% for locations where the yearly average high temperature is above 77'F/25'C and to 135% for locations where it is below 77'F/25"C. For detailed information, refer to I Isl A higher current source may be used; the inverter will limit Its input current to the values stated. It) Revenue grade inverter P/N: 5ExxxxA-US000NNR2 1`1 Rapid shutdown kit P/N: SE1000-110-SI 161-40 version P/N: SExxxxA-1.150001SINLI4 Page 1/2 L'RmRted Warranty Cera rata for REC Peak Energy SaKess kladuks & REC Peak Energy �ntegratad oddees' (valid as of Septemberl, 2011) This Limited Warranty is valid only in North America, Central America and South American and for all REC ProductsS(-as defined above) sold after Septemberl, 2011 or later. REC MODULES PTE. LTD. (hereafter the'Warrantor' or'REC') issues the following voluntary warranty to the end-user who qurchased the Proz1actin orre of the above rrae,nt;wraed c=tries and_pr.t t, e Pru.duct Wo use for t,'- 5rst tdr,7e k+.�e'Crigv.al End -User'). In addition to the rights under this Limited Warranty, the Original End -User maybe entitled to statutory warranty rights under applicable national laws which shall not be affected or limited in anyway by this Limited Warranty. L Product Warranty Subject to the terms and conditions of this Limited Warranty, REC warrants that the Products: • Are -free from defects in material and workmanship for a period of 10 years from the date of purchase by -the Original End -User (not exceeding a maximum period of 10.5 years from the date of production as identified on the Product) (the 'Warranty Period') if installed and used in accordance with the installation instructions available to download fRom www. recgroup.com. Will remain.safe and operational if cable and connector plugs are installed professionally and are not permanently positioned in water; provided however, that damage to the cable caused by abrasion on a rough surface due to insufficient fixing or to unprotected running of the cable over sharp edges is excluded. Damage caused by anim als is also excluded. LL Will not experience freezing up of the aluminum frames if installed correctly. The outer appearance of the Product, including scratches, stains, rust, mould, discoloration and other signs of normal wear and tear, which occurred after delivery or installation, do not constitute defects, provided the functionality of the Rroduct is not affected. Glass breakage constitutes a defect only if not caused by any external influence. If a defect occurs during the Warranty Period affecting the functionality of the Product, REC will, at its sole option: Repair -the defective Product. Replace the Product with an equivalent product. Refund the current market price of an equivalent product at the time of the claim. Ullo t¢'ower Output Warranty Subject to the terms and conditions of this Limited`Warranty, REC warrants that the actual power output of the Product will reach at least 97% of the nameplate power out specified on the Product during the first year (calculated from the date of production as identified on the Product). From the second year, the actual power output will decline annually by no more than 0.7% for a period of 24 years, so that by the end of the 25th year, an actual output of at least 00.2% of the nameplate power out specified on the Product will be achieved. TMs Power Output, Warranty covers only reduced performance due to natuurai degvadatfi®¢t of the glass, the the ernIbeddling fall, qhe fuwctilon bon and sunder warmall use. If the Product does not reach the warranted power output levels set out above when measured by the Warrantor or by an independent measuring institute agreed to prior to testing by the Warrantor, under standard test conditions (IEC 61215) and taking into accour>t a ±3% tolerance range, then REC will, at its sole option: Repairthe Product Replace the Product with an equivalent product or to supply additional modules as necessary to achieve the warranted percentage of specified power output. Refund the current market price of an equivalent product at the time of the claim 1 excluding madulesshowing"Q3"aspart,ofthe product name. z Defined as,atl member states of the Organization of American States, OAS. Rev. G.1, September 2011 This warranty is only applicable in the member states of the Organization of American States, OAS Page 2/2 111111. Warranty Canditaanso L, m Rattans and EEKd us6anz 1. This LimitedWarranty is not transferable by the Original End -User, except to a subsequent owner of the solar {rower facility at which the Product was originally installed and remains installed, provided that this solar power faci[i; y has not been alteredtin any way ormoved from the structure or property at which it was originally installed. 2. Notification of a warrantyclaim hereunder must be given without undue delay after detection of the defect arrd priorto the expiration of the applicable Warranty Period and in accordance with the procedure as set out in section IV below. 3. Rease note that thils L, mated Warranty/ does not cover nor wM the Warrantor retro burse, any an -sate Ilafbor (or other costs ancuurred iin connection with the cr rem ovall of defactave Pr®dluust transp art mgr ahe re- linstappata®n of replaced or repaired Products or any/ components. 4. The Warrantor may use remanufactured or refurbished parts or products when repairing or replacing any Products under this Limited Warranty. Any exchanged or replaced parts or Products will become the property of REC. The Warranty Periods set out in sections I. and 11. dbove will not be extended in any way in the event of a replacement or repair of a Product. 5. This Limited Warranty requires that the Product is installed according to the latest safety, installation and operation instructions provided by REC and does not apply to damage, malfunction, power output or service failures whidh have been caused by: (a) repair, modifications or removal of the Product by someone otherthan a qualified.service technician,• (b) any improper attachment, installation or application of the Product or (c) abuse, misuse, accident, negligent acts, power failures or surges, lightning, fire, flood, accidental breakage, actions of third parties and other events or;accidents outside REC's reasonable control and/or not arising under normal operating conditions. 6. This Limited Warranty is provided voluntarily and free of charge and does not constitute an independent guaraintee promise. -Therefore, ifany defect materiallyaffectsthefunctionality of the Product or -results inapoweroutpwtbelow - the warranted levels, the Original End -User's remedies are limited exclusively to the remedies set out under serctions I. and II. in the warranty cases specified herein. REC ASSUMES RD WARRARMES, EXPRESS OR IMPLlE®p OTHER THAN THE WARRARTIIEES MADE HERElM AVS® SPEO FICAL LY DIISCLAIIMS ALL 07H ER WARRANTIES, MERCHARTABI Ll7 Y OR PIITMESS FOR A PARTpCU(LAR PURPOSE. REC EXCLUDES ALL [LIIAML OTLEES FOR ANY SP'EEClAL, IINC[IDE DTiAL, CONSEQUENTIAL OR PURlTME DAMAGES FROM TIBC USE OR LOSS OF USE OF THE PRODUCTS TO PERFORM AS WARRAN'TE®p 11MCILUDIING BUT MOT LIMITED TO DAMAGES FOR LOSS OF POWER, LOST P'ROR7S OR SAVIINGS7 NOR EXPENSES ARlSl G FROM 7HORD-PART°e CL,AgMiS. This does not apply to the extent the Warrantor is liable under applicable mandatory product liability laws or in cases of intent or gross negligence on the part of the Warrantor. J. This Limited Warranty shall be governed by and construed in accordance with the laws of the State of CaliforniEa without giving effect to its conflict of laws provisions. The United Nations Convention on Contracts for the International Sale of Goods (1900) shall not apply to or govern this Limited Warranty or any aspect of any dispute arising there from. kl.V Warranty call oo Procedure Claims under:this:Limited Warranty must be made by.notifying the authorized distributor or seller where the Product was first purchased. A claim may be registered at: www.recgroup.com/warranty For Warranty Claim to be processed, proof of the original purchase of the Product and any subsequent sales including transfer of this Warranty need to accompany the claim. The claim must include a description of the alleged defect(s) as well as the Product's serial number(s). Prior to returning any Products or components to REC, an RMA (Return Merchandise Authorization) number is required, which may be obtained by contacting REC via the aforesaid address. This warranty is valid for Products sold on or after September 1, 2011. Sangapore' Ca)09.2©11i pv�v�v�.,a„ev�ve ao 0o ao 00 00 00 This warranty is only applicable in the member states of the Organization of American States, OAS Rev. G.1, September 2011 m SNAPNRACK COMPOSITION L FOOT CAN BE MOUNTED IN ANY ORIENTATION SNAPNRACK CHAIrn NUT SNAPNRACK STANDARD RAIL SNAPNRACK COMPOSITION ROOF FLASHING A' S.S. LAG SCREV WITH FLAT VASHER 2.5' MINIMUM EMBEDMENT IS STANDARD SNAPNRACK L FOOT BASE SEAL PENETRATION AND UNDER BASE WITH APPROPRIATE ROOF SEALANT RAFTER TYP. A X V S.S. BOLT AND SPLIT WASHER - A S.S. FLANGE NUT ROOF DECKING TYP. FLASHED L FOOT MOUNTING POINT FOR USE ON COMPOSITION ROOF" SURFACES WITH LOW TO MODERATE TILT RAILS CAN BE LEVELED UP TO 3' USING UP TU TWO LEVELING SPACERS AS SHOVH IN 'SERIES 100 RAIL LEVELING' G.MCPHEETERS ISCAIE I DNS PART G. MCPHEETERS DATE 1zo111 PEN-DO1 �«v N NOTES- - - a - 5/16' LAG BOLTS MUST EMBED ---- Z 2S' INTO ROOF STRUCTURAL MEMBERS/RAFTERS - TORGUE ALL 5/16' HARDVARE TO [1 THE FULLOVING X - SILVER S.S. 10-16 FT -LBS 3 - BLACK S.S. 7-9 FT -LBS !n - RAILS CAN MOM TO EITHER SIDE m OF L FUOT (UPSLOPE VS DOVNSLOPE) Z) m to J STEP 3, PLACE L FOOT ON TOP o OF FLASHING AND TIGHTEN NOT o STEP 2, SLIP O FLASHING OVER O L FOOT BASE _n STEP D BOLT L FOOT BASE TO ROOF WITH O LAG BOLT C Z D r r D -I O ROOF DECKING TYP. Z Z C D 1�S�PL�ATI�N r CD��EjED PEN DETAIL 01 FLASHED L, FOOT I�" E SITE PLAN - SCALE = 1/16" = 1'4" PITCH TRUE MAG PV AREA AZIM AZIM (SQFT) ® AR -01 16° 1 ° -13° 426.3 AR -02 16° 91' 77° 88.8 AR -03 16° 271° 257° 88.8 MP - INV SM SE PL PL PL PL PL PL r (N) ARRAY AR -01 (E) RESIDENCE a v y r FIRE SETBACKS - (N) ARRAY AR -02 (3' TYP) J a f sunrun FT J CA CL #750184 a • 2300 ZANKER ROAD, UNIT F, SAN JOSE, CA 95131 PHONE 408.746.3062 FAX 408.894.9294 Rq/Ng0w0/� JAMES BRE OS RESIDENCE: PL 7733 RAINBOW DR CUPERTINO CA USA 95014 t a _ Rr 1 p( d '. r CUPS a ��� TEL. (408) 446-2160 APN#:36224017 i ull'ing DopEtkmn1 PROJECT NUMBER: (N) ARRAY AR -03 p( ` �� 102R-733BRE1 jUN 0 8 201 DESIGNER: REVIEWED FOR (.#ODE COMPLIANCE M. SHAWGO / 905.540 7670 Revi,evvea H- y Jew, hr,"lli DRAFTER: DI SHEET SITE PLAN REV: A.2 5/13/2015 PAGE PV -2.0 SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE # DESCRIPTION • SYSTEM SIZE: 8840W DC, 7600W AC 0 ALL WORK SHALL COMPLY WITH 2013 CEC, 2013 CBC, 2013 CRC, MUNICIPAL CODE, SE SERVICE ENTRANCE SOLAR MODULES PV -1.0 COVER SHEET • MODULES: (34) REC SOLAR: REC260PE(BLK) AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. RAIL PV -2.0 SITE PLAN • INVERTER(S): . PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2013 CEC. PV -3.0 LAYOUT (1) SOLAREDGE TECHNOLOGIES: SE760OA-US (240V) • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH 2013 CEC. MP MAIN PANEL • RACKING: SNAPNRACK SERIES 100 UL; FLASHED L FOOT. • PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY SEE PEN D01. GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35. PV -4.0 ELECTRICAL • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. SP SUB -PANEL STANDOFFS & PV -5.0 SIGNAGE • MAIN PANEL REPLACEMENT: EXISTING 100 AMP MAIN • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. FOOTINGS PANEL WITH AMP MAIN BREAKER TO BE REPLACED . RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. WITH NEW 1255 AMP MAIN PANEL WITH 100 AMP MAIN CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(E) AND 2012 IFC 605.11.2. PV LOAD CENTER � CHIMNEY Fe BREAKER. ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. • 9.01 AMPS MODULE SHORT CIRCUIT CURRENT. SM SUNRUN METER � ATTIC VENT • 14.07 AMPS DERATED SHORT CIRCUIT CIRCUIT (690.8 (a) & 690.8 (b)). JUN 2015 PM DEDICATED PV METER FLUSH ATTIC VENT o PVC PIPE VENT �Y INVERTER(S) WITH j. LOT PLA, CHECKED BY [INV] INTEGRATED DC ® METAL PIPE VENT - /� 0y) C,\ DISCONNECT DISCONNECT AND AFCI � T -VENT D- ATE (�jr t y; j IAC DISCONNECT(S) SATELLITE DISH PLANNING DEPT CUPERTINODC 1E DC DISCONNECT(S) FIRE SETBACKS 1 CB IEEidi F__1.'__1 COMBINER BOXHARDSCAPE -1 F INTERIOR EQUIPMENT — PL— PROPERTY LINE LL jJ SHOWN AS DASHED SCALE: NTS sunrun G® A AMPERE AC ALTERNATING CURRENT ` AFCI ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTCOMPOF# ,-„r PC .}ry+p^yKyr �( COMP CQMPQ <tMdr ppv,�1�P Lie i A INN DC DIRECT; R. _PI. f?0(ling De ttTite'f)t CA CL #750184 2300 ZANKER ROAD, UNIT F, SAN JOSE, CA 95131 PHONE 408 746 3062 FAX 408.894,9294 VICINITY MAP O (E) EXT EXISTIPiu EX I'' ! JUN ZO�� CUSTOMER RESIDENCE. i SquonswudWcy �� Musm Tunnel K1v N r DeAnYA ..., . ,.. Snnpprny Center Lockiox6 �' FRM INT LBW FRAMING INTERIOf'Ery/jEr D t OR WORE COMPLIANCE JAMES BREILING 7733 RAINBOW DR S o MAG LOAD BEARING WALL MAGNETIC ReViowed gy CUPERTINO CA USA 95014 Hollanderry t>I o 85C Bak" ., Cate - San Jose pMENT DF- R ENT MSP (N) MAIN SERVICE PANEL NEW TEL,(408)446-2160 APN# 36224017 PROJECT NUMBER: DEVELO GUPERTINO NTS obindeuway n lCingsGurYFI COMMUNITY DIV1S10N NOT TO SCALE 102R-733BRE1 a ' gU1LDING APPROVE (� at the OC ON CENTER SquirehillCf m �m r �. .. d �_",._ specifications MU ST be kept PRE -FAB PSF PRE -FABRICATED DESIGNER: - This set of p tans and It is un" or to deviate POUNDS PER SQUARE FOOT Ash-h�°„' R constructioany n. job site during e, On sam PV TL PHOTOVOLTAIC TRANSFORMERLESS M. SHAWGO 805 540 7670 DRAFTER: 7T33RainbowOr changes or alterations guildingOffloial. Chang T Without approval fro SN.�1 L NO TYP TYPICAL a therefrom, (.lcat��ons of this p"a tion VOLTS DI 0rangeBlossom 0, ,y The Stamp!ng r er t e or State La"'. held to P W WATTS SHEET REV NAME DATE COMMENTS Peach Blossom Dr Yamagarnis Nursery 6 be COVER SHEET of any C7 A BYZ �6_"- S REV: A.2 5/13/2015 """,nd1 w'"' - PERMIT # PV -1.0 ROOF TYPE ATTACHMENT ROOF HEIGHT ROOF EXPOSURE FRAME MATERIAL FRAME TYPE FRAME SIZE MAX FRAME SPAN OC SPACING ROOF EDGE ZONE MAX RAIL SPAN MAX RAIL OVERHANG DESIGN CRITERIA MODULES: AR -01 COMP SHINGLE FLASHED L FOOT. SEE PEN D01. SINGLE STORY ATTIC WOOD RAFTER 2 X 6 T- 0" 24" YES 6'- 0" 2' - 0" REC SOLAR: REC260PE(BLK) AR -02 COMP SHINGLE FLASHED L FOOT. SEE PEN D01. SINGLE STORY ATTIC WOOD RAFTER 2 X 6 T- 0" 24" YES 6'- 0" 2'- 0" MODULE DIMS: AR -03 COMP SHINGLE FLASHED L FOOT. SEE PEN D01. SINGLE STORY ATTIC WOOD RAFTER 2 X 6 T- 0" 24" YES 6'- 0" 2'- 0" 65.55" x 39.02" x 1.5" MAX DISTRIBUTED LOAD: 3 PSF D1 - AR -01 - SCALE: 1/8" = 1'-0" ROOF FRAMING DETAIL - SCALE: NTS SNOW LOAD: 0 PSF PITCH: 16° WIND SPEED: AZIM: 1' RIDGE BOARD 110 MPH 3 -SEC GUST. ® COLLAR TIE @ 48" OC - LAG SCREWS: -3'- 39'-6" 5/16"x4.0": 2.5" MIN EMBEDMENT 5/16" X 4.0" LAG SCREW. �I 1 BOLT PER PENETRATION 3' I COMP SHINGLE ROOF SOLAR MODULE 6' TYP-6 o-- 10'-11" 0.- 4 0-- - - O - - TOP PLATE o— PURLIN O-- 0 - 2X6 RAFTERS, 24" O.C. INTERIOR WALL LOAD BEARING WALL- CUPER II ING D2 - AR -02 - SCALE: 3/16" = 1'-0" PITCH: 16° AZIM: 91' D3 - AR -03 - SCALE: 3/16" = 1'-0" PITCH: 16°'07 AZIM: 271' �+ I n .0w. �U� 2��5 sunrun ® ® REVIEWED FOR CODE COMPLIANCE. Reviewea By: f�Rr�•% CA CL #750184 16'-5" 2300 ZANKER ROAD, UNIT F, SAN JOSE, CA 95131 PHONE408.746.3062 FAX 408 .894.9294 y) CUSTOMER RESIDENCE: I � 3' I JAMES BREILING 3' 7733 RAINBOW DR CUPERTINO CA USA 95014 0— I ----._Q A TEL. (408) 446-2160 APN #: 36224017 5'-6" PROJECT NUMBER: 5'-6" 102R-733BRE1 — _O DESIGNER: M. SHAWGO 805 540.7670 DRAFTER: DI SHEET LAYOUT REV: A.2 5/13/2015 PAGE PV -3.0 120/240 VAC SINGLE PHASE SERVICE CONDUIT SCHEDULE # #: CONDUCTOR NEUTRAL GROUND 1 NONE (4) 10 AWG PV WIRE OMETER M PGE 1005143499 2 3/4" EMT OR EQUIV. (4) 10 AWG THHN/THWN-2 NONE UTILITY 3 3/4" EMT OR EQUIV. (2) 8 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 GRID NEW 100A (MAIN T BREAKER NEW 125A MAIN SOLAREDGE TECHNOLOGIES: PANEL (N) SUN RUN SE760OA-US (240V) FACILITY METER 7600 WATT INVERTER PV MODULES LOADS - �'+L}�cR�INO 3 3 2 1 REC SOLAR: REC260PE(BLK) I""fig ' `2 BuildingD9�JEIf$11l1111` (34) MODULES a G— OPTIMIZERS WIRED IN (2) SERIES - I OF (17) OPTIMIZERS ` JUN 0 8 2015 FACILITY JUNCTION BOX 40A PV GROUND 250V METER SOCKET LOAD RATED DC MIN RATED NEMA3R SOLAREDGE POWER OPTIMIZER REVIEWED FOR tfODE GUIIAPLIANCE BREAKER AT 125A CONTINUOUS & DISCONNECT & AFCI P300 OPPOSITE END 240V METER Reviewer By s,►rlw/ OF BUSBAR 200A, FORM 2S CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4) 10 AWG PV WIRE NONE (1) 10 AWG BARE COPPER 2 3/4" EMT OR EQUIV. (4) 10 AWG THHN/THWN-2 NONE (1) 8 AWG THHN/THWN-2 3 3/4" EMT OR EQUIV. (2) 8 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 MODULE CHARACTERISTICS REC SOLAR: REC260PE(BLK) 260 W OPEN CIRCUIT VOLTAGE 37.8 V MAX POWER VOLTAGE 30.7 V SHORT CIRCUIT CURRENT 9.01 A OPTIMIZER CHARACTERISTICS MIN INPUT VOLTAGE 8 VDC MAX INPUT VOLTAGE 48 VDC MAX INPUT ISC 10 ADC MAX OUTPUT CURRENT 15 ADC SYSTEM CHARACTERISTICS - INVERTER 1 SYSTEM SIZE 8840 W SYSTEM OPEN CIRCUIT VOLTAGE 17 V SYSTEM OPERATING VOLTAGE 350 V MAX ALLOWABLE DC VOLTAGE 500 V SYSTEM OPERATING CURRENT 25.3 A SYSTEM SHORT CIRCUIT CURRENT 30 A PER CODE: NEC 690.52 NOTES TO INSTALLER: 1. 17 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE. 2. ADD 40 AMP PV BREAKER TO MAIN PANEL. SOLAREDGE SYSTEM NOTES: 1. SOLAREDGE INVERTER AND OPTIMIZERS ARE A LISTED SYSTEM. 2. STRING OPERATING VOLTAGE IS CONTROLLED BY INVERTER AND MAINTAINED AT 350V DC (NOMINAL). 3. STRING VOLTAGE IS ELECTRONICALLY LIMITED BY INVERTER TO 500V DC, MAX. 4. STRING CURRENT IS CONTROLLED BY OPTIMIZERS AND IS ELECTRONICALLY LIMITED TO 15A MAX (PER STRING). 5. SOLAREDGE DC SAFETY SWITCH DISCONNECTS BOTH POSITIVE AND NEGATIVE DC CONDUCTORS AS REQUIRED BY NEC690.35(A). 6-12 AWG BARE 5/16"-18 SS BOLT COPPER WIRE SS SPLIT LOCK WASHER i - (TORQUE TO 16 FT -LBS) / \ SNAPNRACK \ \ GROUND LUG BONDING \ CHANNEL NUT RAIL SS BONDING PINS NOTE: • ALL HARDWARE IS INCLUDED FROM MANUFACTURER • A MINIMUM OF ONE GROUND LUG IS TO BE INSTALLED ON EVERY CONTINUOUS ROW OF MODULES • GROUNDING LUG MAY BE INSTALLED IN EITHER RAIL CHANNEL • GROUNDING LUG MAY BE INSTALLED SO GROUND WIRE IS PARALLEL OR PERPENDICULAR TO RAIL • ENSURE SPLIT LOCK WASHER IS INSTALLED ON TOP OF COPPER WIRE SNAPNRACK GROUNDING SCALE: NTS AWARNING ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED LABEL LOCATION: DC DISCONNECT, INVERTER (PER CODE: CEC 690.35(F)) [To be used when inverter is ungrounded] A WARNING ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED LABEL LOCATION: DC DISCONNECT, INVERTER (PER CODE: CEC 690.35(F)) [To be used when inverter is ungrounded] A WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: CEC 690.17(E)) A WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL L.00AIION: AC DISCONNECT, POINT OF INTERCONNECTION PER CODE: CEC 690.17(E), CB LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: CEC690.54) LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: CEC 705.12(D)(7)) [Not required if panelboard is rated not less than sum of ampere ratings of all overcurrent devices supplying it] CAUTION: SOLAR CIRCUIT LABEL: CONDUIT, RACEWAYS, ENCLOSURES LABEL LOCATION: INVERTER, JUNCTION BOXES (ROOF), AC DISCONNECT (PER CODE: CEC690.13.G.3 & CEC 690.13.G.4) LABEL LOCATION: CONDUIT, COMBINER BOX (PER CODE: CEC690.31(G)(3)(4) & CEC 690.13(G)(4) ADHESIVE FASTENED SIGNS: • THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. • WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS, AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4 [NEC 110.21(B) FIELD MARKING]. • ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.1.3] LABEL LOCATION: DISCONNECT, POINT OF INTERCONNECTION (PER CODE: CEC690.13(B)) LABEL LOCATION: DC DISCONNECT, INVERTER (PER CODE: CEC690.53) AWARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: CEC 705.12(D)(4)) CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: CEC690.15, 690.13(8)) UPE .rttr►>� IN Depent �Uili` t J�� 0 2015 �EVIEVVED AOR LOUE COMPLIANCE Revieweu By ..