Loading...
15080113CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 22045 CREEKSIDE CT CONTRACTOR: REC SOLAR, INC. PERMIT NO: 15080113 OWNER'S NAME: MO-YUN & THEODORE FONG 775 FIERO LN STE 200 DATE ISSUED: 08/14/2015 OWNER'S PHONE: 6503876530 SAN LUIS OBISPO, CA 93401 PHONE NO: (888)657-6527 LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL COMMERCIAL ❑ INSTALL 25 ROOF TOP, FLUSH MOUNTED PV MODULES, License Class Li # 6.8KW —(!f —/;- Contractor Date �f I hereby off./r. that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the )Performance of the work for which this permit is issued. Sq. Ft Floor Area: Valuation: $14200 I have and will maintain Worker's Compensation Insurance, as provided for by APN Number: 32639041.00 Occupancy Type: Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITHIN 180 D ISSUANCE OR to building construction, and hereby authorize representatives of this city to enter 180 DA CALLED INSPEC ION. upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless City of Cupertino against liabilities, judgments, �. !J costs, and expenses which mA accrue against said City in consequence of the ed granting of is it. itionally, the applicant understands and will comply41A with all non oint ou regula ' er upertino Municipal Code, Section — RE -ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is 9.18. A. Signature Date ! installed without first obtaining an inspection, I agree to remove all new materials for inspection. ❑ OWNER -BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I_ am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) 1, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(a) should I store or handle hazardous I have and will maintain a Certificate of Consent to self -insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the Bay a Air Quality Management District I Code, Chapter 9.12 and performance of the work for which this permit is issued. will maintain compliance cip the Health & Safety Code, 2 3 , a 25534.Section I have and will maintain Worker's Compensation Insurance, as provided for by for this *thrtino 3700 of the Labor.Code, for the performance of the work which Owner or authorized ageDate:v permit is issued. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's CONSTRUCTION LENDING AGENCY Compensation laws of California. If, after making this certificate of exemption, I I hereby affirm that there is a construction lending agency for the performance of become subject to the Worker's Compensation provisions of the Labor Code, I must work's for which this permit is issued (Sec. 3097, Civ C.) forthwith comply with such provisions or this permit shall be deemed revoked. Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section Licensed Professional 9.18. Signature Date CUPERTINO ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building(Dcupertino.org /JZ2gU/i3 PROJECT ADDRESS a y�- cRk: IpfC. - _74 OWNERN AME FDQV! r p E-MAIL P1E,b.' STREET ADDRESS (/ , CITY, STATE, ZIP FAX CONTACT NAME .n. /nWy� P ��j� r (j� E -T l J�'"� / ! mit (,vn� E STREET ADDRESS 7_3 no CITY, STAy�, ZIPi /% QJj�j J) /❑l FAX ❑ owi,,ER ❑ OwNER-BUILDER ❑ OWNER AGENT ❑ CONTRACTOR AaoNTrRACTORAGENT ❑(ARCHITECTT ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME C, , - ! /I ( LICENSE NUMBER / % LICENSE TYPE BUS. LIC \A. Fr COMPANY NAMEl/V E-MAIL FAX STREET ADDRESS B y; J N /CA CITY, J • �7�I r R®. . O D 716 ARCHITECT/ENGINEER NAMEHP1460 LICENSE NUMBER BUS. LIC 9 COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHO USE OF ❑ SFD or Duplex ❑ Multi -Family PROJECT IN WILDLAND PROJECT IN STRUCTURE: ❑ Commercial URBAN INTERFACE AREA ❑ Yes ❑ NO FLOOD ZONE ❑ Yes ❑ NO ❑ SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PANELS: NUMBER OF PANELSIUNITS: 2,5 KILOWATTS (COMMERCIAL ONLY): 6 TOTAL VALUATION I ;20(2 DESCRIPTION OF WORK f / 1 _ / fM L-70,4 / S ..` By my signature below, I certify to ea the f owing: I er or authorized agent to act on the p e owner's behalf. I have read this ;e'?0f'E1Des7pti'Dn application and the information I ha pro i is correct. - ave of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to bui onstruction. I a t e representatives of Cupertino to enter the abov identi d pr for inspection purposes. ✓ Signature of Applicant/Agent: Date: S,fJPPL MENTAL INFORMATION REQUIRED i�s"o`ctrsQ tis 7; . �..,s� :!T. .. � Qj kt, HFSCOIJI TERz:,'r' x y,:F; t s 1 j zBTJ- ��',.,C�"s: J tfG d'{�Y♦J'.e'Ff £f#,1'4' tLA'RGE�.»,k��.,.�k.�p;�,�4"�N PiIApp_2011.doc revised 03/16111 CITY OF CUPERTINO FWAMN FF.F F4TIMATOR — BUILDING DIVISION NOTE: This estimate does not.inelude fees due to other Departments (Le.Planning, Puattc rrurns, Ptrc, our—My [' tin available and are onl an estimate. Contact the Dept or addn'l into. Distract, etc . These eeare based on the re tmtna FEE ITEMS (Fee Resolution 11-053 E . 7if 113) 22045 CREEKSIDE CT DATE: 08/14/2015 REVIEWED BY: MELISSA ILIADDRESS: APN: 326 39 041 BP#: 0 "`VALUATION: 1$14,200 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY SFD or Duplex USE: Pluurb. hrsp. Fee: PENTAMATION SOLAR -RES PERMIT TYPE: i WORK INSTALL 25 ROOF TOP FLUSH MOUNTED PV MODULES 6.8kW SCOPE Suppl. Insp. Feer Reg. 0 OT NOTE: This estimate does not.inelude fees due to other Departments (Le.Planning, Puattc rrurns, Ptrc, our—My [' tin available and are onl an estimate. Contact the Dept or addn'l into. Distract, etc . These eeare based on the re tmtna FEE ITEMS (Fee Resolution 11-053 E . 7if 113) ,tlech. Plan Check Plumb. Plan Check Elec, Plan Check alech. Peron! Fee: Plumb. Permit Fee: Ve.c. Perr,rir lie: Ocher ;tlech. Insp. Orlrer Plumb Insp. Li Other Elec. Imp.1•Jcrh. ELL��j Insp. l"ec: Pluurb. hrsp. Fee: Flee. Insp. Fee: Permit Fee: $0.00 NOTE: This estimate does not.inelude fees due to other Departments (Le.Planning, Puattc rrurns, Ptrc, our—My [' tin available and are onl an estimate. Contact the Dept or addn'l into. Distract, etc . These eeare based on the re tmtna FEE ITEMS (Fee Resolution 11-053 E . 7if 113) rmas an oo FEE QTY/l MISC ITEMS Plan Check Fee: $0.00 C1 # Alternative Energy System $236.00 IPHOTOVRES Photovoltaic System Suppl. PC Fee: (j) Reg. 0 OT 0.0 hrs $0.00 PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Feer Reg. 0 OT 0.0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 Construction Tax: __F_T A..dinini strati ve 1, ee: 0 G Work Without Permit? 0 Yes (F) No $0.00 Advanced Planning Fee: $0.00 Select a Non -Residential G Building or Structure 0 -F7= Trwvl Doeuinenlal on Fees: Strong Motion Fee: IBSEISMICR $1.85 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $1.00 _ SUBT,OTALS:' $2.85 $236.00 TOTAL FEE $238.85 mevl5eu: U r rvcrcv r a O0N /SCS 3b //� HIGH PERFORMA CE SOLAR PANELS OREE PEAK ENERGY EC Peak Energy Series panels are the perfect choice for building solar systems that combine long lasting product quality with reliable power output. REC combines leading standards of design and manufacturing to produce high- performance solar panels with uncompromising quality. MOREPOWER ROBUSTAND PER FT' DURABLE DESIGN � OOr T AFF ENERGY PAYBACK US IMPORT TIME OF ONE YEAR DUTY FREE REC PEAK ENERGY SERIES 65.55:0.1 1.1 3543 I516 EFFICIENCY • , YEAR PRODUCT WARRANTY YEAR LINEAR POWER OUTPUT WARRANTY -o� a 0.43 n ± 0.08 ' 6,6 Mounting holes - All measurements in inches Nominal Power - P,,,(Wp) 240 245 250 255 260 265 Watt Class Sorting -(W) 0/+5 0/+5 0/+5 0/+5 0/+5 0/+5 Nominal Power Voltage -VMPP(V) 29.7 30.1 30.2 30.5 30.7 30.9 Nominal Power Current-Im,,(A) 8.17 8.23 8.30 8.42 8.50 8.58 Open Circuit Voltage-Vor(V) 36.8 37.1 37.4 37.6 37.8 38.1 Short Circuit Current-Ist(A) 8.75 8.80 8.86 8.95 9.01 9.08 Panel Efficiency(%) 14.5 14.8 15.1 15.5 15.8 16.1 Analysed data demonstrates that 99.7%of panels produced have current and voltage tolerance of ±3% from nominal values. Values at standard test conditions STC (airmass AM1.5, irradiance 1000 W/m', cell temperature 25'C). At low irradiance of 200 W/ml (AM 1.5 and cell temperature 25'C) at least 96% of the STC panel efficiency will be achieved. REC240PE Nominal Power -PMpp(Wp) REC24SPE 183 187 REC25OPE0• 189 193 197 202 NominaIPowe rVoltage-VMPP(V) 27.7 28.1 28.3 28.5 29.0 29.4 Nominal Power Current - IMpp(A) 6.58 6.64 6.68 6.77 6.81 6.90 Open Circuit Voltage - Vu, IV) 34.4 34.7 35.0 35.3 35.7 36.0 Short Circuit Current - Isr(A) 7.03 7.08 7.12 7.21 7.24 7.30 Nominal operating cell temperature N 0 C T (800 W/m', AM 1.5, wind speed I m/s, ambient temperature 20'C). �UrY,FR US IMPORT DUTY FREE FF TEMPERATURE R ATI NGS Nominal Operating Cell Temperature(NOCT) 45.7°C(±2°C) TemperatureCoefficlien tofPM,, -0.40%/'C Te mpera tu re Coeffic ien t of V,,, -0.27%/'C Temperature Coefficient of 1, 0.024%/-C Cell Type: 60 REC PE multi -crystalline 3 strings of 20 cells with bypass diodes Glass: 1/8' mm solar glass with anti -reflection surface treatment Back Sheet: Double layer highly resistant polyester Frame: Anodized aluminum (silver) Junction Box: IP67 rated 4 mm2 solar cable, 35' + 47" Connectors: Multi -Contact MC4 (4 mm2) Origin: Made in Singapore Operational Temperature: Maximum System Voltage: Design Load*: Max Series Fuse Rating: Max Reverse Current: -40_ +85'C 600 V 75.2 lbs/ft2(3600 Pa) 33.41bs/ft2 (1600 Pa) 'Refer to installation manual 15A 15A O Fff-il 10 year linear owero tp Dimensions: 651/2 x39x3//2in C ill ns L 25 year linear power output warranty Area: 173/aft2 @LKM (ma x.degression in performance of0.7% p.a.). IEC 61215, IEC 61730 & UL 1703; IEC 62716 (Ammonia Weight: 391/21bs Resistance) IEC 61701(5aIt Mist - severity levels 1 & 6). Note! All given specifications are subject to change - IEC 60068-2-68 (Blowing Sand) without notice atany time. REC is a leading global provider of solar energy solutions. With more than 15 years of experience, we offer sustainable, high performing ^ products, services and investments for the solar industry. Together with our partners, we create value by providing solutions that '!` better meet the world's growing energy needs. REC is headquartered in Norway and listed on the Oslo Stock Exchange (ticker: RECSOL). Our 1,600 employees worldwide generated revenues of USD 647 million in 2013. www.recgroup.com MECHANICAL INSTALLATION FIRE GUIDELINES REC Peak Energy Series panels have a Class C, Type 1 Fire classification. The fire rating of this panel is only valid when mounted in the manner specified in these mechanical mounting instructions. Utilize the following fire safety guidelines when installing REC Peak Energy Series panels: • Check with local authorities for fire safety guidelines and requirements for any building or structure on to which the panels will be installed. • The system design should ensure that it can be easily accessed in the event of a building fire. • Check with local authorities for applicable regulations concerning setbacks or other placement restrictions that may apply for roof -mounted arrays. • The use of DC ground fault interrupters is recommended. This may also be required by local and national codes. • All electrical appliances are a fire risk. The panel should therefore be mounted over a fire retardant roof covering rated for the application and a suitable distance of 4 in between the panel and the mounting surface, allowing free circulation of air beneath the panels, should be respected at all times. ORIENTATION To maximize system output, panels should be installed at the optimum orientation and tilt angle. The specifics of this depend on location and can be calculated by a qualified system designer. A lower angle of panel installation increases the requirement for regular cleaning. The optimal mounting position of panels results in the sun's rays falling perpendicular (i.e. at 90•) to the surface. All panels in a string should, wherever possible, have the same orientation and tilt to ensure the system does not underperform due to mismatched outputs. ! The panels must not be exposed to artificially concentrated sunlight ENVIRONMENTAL FACTORS REC Peak Energy Series panels are designed to provide decades of durable and stable output. Operating temperatures should be between -40 and 185•F (-40 and +85•C). The panels are not suitable for installation in potentially hazardous locations nor should they be installed in the following locations: • Near sources of flammable gases or vapors • Near open flames. • Under water or in water features. • Where exposed to sulfur e.g. near sulfur springs or volcanoes. • Where the panels may be exposed to harmful chemicals. QEnsure panels are not exposed to direct contact with salt water/spray and avoid installation in areas subject to high salt mist content e.g. • coastal areas. PANEL HANDLING Panels should be handled with care. All warnings and instructions on the packaging should be observed. Follow these guidelines when unpacking, transporting or storing the panels: • Record the serial numbers prior to installation and note the information in the system documentation. • Carry the panels using both hands and avoid using thejunction box as a grip. • Do not allow the panels to sag or bow under their own weight when being carried. • Do not subject the panels to loads or stresses e.g., leaning or placing heavy objects on them. • Do not stand on the panels or cause impact through dropping them. • Keep all electrical contacts clean and dry. • Store panels in a dry and properly ventilated room. • Do not apply force to the backsheet. • Avoid using sharp or pointed objects if panels require marking. • Never apply paints, adhesives or detergents to the back of the laminate. • Do not use any solar panel that is damaged or been tampered with. • Never attempt to disassemble the panels. QIf the panel front glass is broken or laminate back sheet is damaged, it can expose personnel to hazardous voltages. How to Configure Your System First calculate the spans and penetration count. There is a SnapNrack span calculation table on the back of this Manual. Determine site conditions: general building height, array pitch, the wind speed, and snow load or topographical condition. Find appropriate railspan from table. Span Table Example Building Height 0 - 30 ft Array Pitch 160 2012 IBC Wind Speed 120 mph Snow Load 8 IbS/ft2 Topo. Cond. None Rail Span 104" Rail Span on 24" spacing roof 96" (8 ft) Do edge/corner reductions apply Yes, shaded cell Edge Zone Span 72" (6 ft) Corner Zone Span 24" (2 ft) 0-30 ft. Roof Height *CS -Consult Structural Engineer RAIL SPAN RAIL END OVERHANG (NOT TO EXCEED 34% OF ACCEPTABLE RAIL SPAN) MODULE OVERHANG (NOT TO EXCEED 2501 OF MODULE LENGTH) Table 1A: Rail Spans (in) for Roof Slopes and Tilt Angles 0' to 19' 6063AIloy Wind L,XIJ k'ull 110 IIS 120 125 130 135 140 145 150 155 160 170 1 Ir0 190 46 15.5 16.9 18.4 20.0 21.6 23.3 25.1 26.9 28.8 30.7 32.5 1 37-0 1 41.5 46_2 P P, -10.' -I I.i -l.? -13.8 -14.9 -16.1 -1?3 -I X.M1 -Iv.9 -?I' 226 -_55 ,X6 -ilv 0 0 _ 10 5 20 1s 30 23 75 ?5 11 75 40 31 66 M 66 66 66 6fi 66 50 39 60 M1O 60 MI 60 60 60 60 60 60 60 46 55 j5 55 55 55 5j 55 55 55 Cj jj .. 70 54 51 51 5t q 51 51 51 51 51 51 51 51 1 51 Jill M1� 4X 4X U U 4X 49 4X 4X U 4K 4X 49 1 41 4X *CS -Consult Structural Engineer RAIL SPAN RAIL END OVERHANG (NOT TO EXCEED 34% OF ACCEPTABLE RAIL SPAN) MODULE OVERHANG (NOT TO EXCEED 2501 OF MODULE LENGTH) 12/9/2014 QIMS.E359313- Mounting Systems, Mounting Devices, Clamping Devices and Ground Lugs for Use with Photovoltaic Modules and Panels QIMS.E359313 Mounting Systems, Mounting Devices, Clamping Devices and Ground Lugs for Use with Photovoltaic Modules and Panels Page Bottom Mounting Systems, Mounting Devices, Clamping Devices and Ground Lugs for Use with Photovoltaic Modules and Panels See General Information for Mounting Systems, Mounting Devices, Clamping Devices and Ground Lugs for Use with Photovoltaic Modules and Panels SUNRUN SOUTH LLC, DBA SNAPNRACK 775 Fiero Ln Suite 200 San Luis Obispo, CA 93401 USA E359313 Investigated Investigated for System Fire Cat. for Mechanical classification No. I Bonding Loading (A, B or C) I Tested in Combination With Photovoltaic mounting system SeriesI Y 350 SeriesI Y 100 UL Listed PV Modules: REC Solar AS: REC214, REC215, REC220, REC225, REC230, REC235, REC240, REC245, REC250, REC255, REC260, REC265, REC270, all followed by PE, PE(BLK), PE -US, PE-US(BLK), PE Q2 or PEQ3. Hyundai Heavy Industries Co Ltd: HiS-MxxxMG Series - HiS-M210MG, HiS-M213MG, HiS-M215MG, HiS-M218MG, HiS-M220MG, HiS-M223MG, HiS-M225MG, HiS- M228MG, HiS-M230MG, HiS-M233MG, HiS-M235MG, HiS-M238MG, HiS-M240MG, HIS-M243MG, HiS-M245MG, HiS-M248MG, HiS- M250MG, HiS-M253MG, HiS-M255MG, HiS-M258MG, HiS-M260MG, HiS-M263MG, HiS-M265MG, HiS-M268MG, HiS-M270MG; HiS-SxxxMG Series - HiS-S220MG, HiS-S223MG, HiS-S225MG, HiS-S228MG, HiS-S230MG, HiS-S233MG, HiS-S235MG, HiS- S238MG, HiS-S240MG, HiS-S243MG, HiS-S245MG, HiS-S248MG, HiS-S250MG, HiS-S253MG, HiS-S255MG, HiS-S258MG, HiS- S260MG, HiS-S263MG, HiS-S265MG, HiS-S268MG, HiS-S270MG, HiS-S273MG, HiS-S275MG; all may be followed by the suffix BK or blank. Renesola Jiangsu Ltd: JCxxxM-24/BB Series - JC200M-24/13b, JC205M-24/Bb, JC210M-24/13b, JC215M-24/13b, JC220M-24/13b, JC225M-24/13b,JC230M-24/13b,JC235M-24/13b,JC240M-24/13b, JC245M-24/13b, JC250M-24/13b, JC255M-24/Bb, JC260M-24/13b, JC265M-24/Bb, JC270M-24/13b. Suniva Inc - MVX-235-60-5-701, MVX-240-60-5-701, MVX-245-60- 5-701, MVX-250-60-5-701, MVX-255-60-5-701, MVX-260-60-5-701, MVX-265-60-5-701; MVX-235-60-5-7131, MVX-240-60-5-7131, MVX-245-60-5-7131, MVX- 250-60-5-7131, MVX-255-60-5-7B1, MVX-260-60-5-7B1, MVX-265- 60-5-761; OPT -250-60-4-800, OPT -255-60-4-800, OPT -260-60-4-800, OPT - 265 -60-4-800, OPT -270-60-4-800, OPT -275-60-4-800; OPT -250-60-4-8130, OPT -255-60-4-8130, OPT -260-60-4-8130, OPT - 265 -60-4-8B0, OPT -270-60-4-8130, OPT -275-60-4-8130. Yingli Energy (China) Co Ltd - YLXXXP-29b Series - YL215P-29b, YL220P-29b, YL225P-29b, YL230P-29b, YL235P-29b, YL240P-29b, YL245P-29b, YL250P-29b, YL25513-29b, YL26013-29b; YLXXXA-29b Series - YL220A-29b, YL225A-29b, YL230A-29b, YL235A-29b, YL240A-29b, YL245A-29b, YL250A-29b, YL255A-29b. http://database.ul.com/cgi-birVXYVItemplate/LISEXT/1 FRAM Elshawpage.htmI?name=QIM S.E359313&ccrishorttitle=Mounting+Systems,+Mounting+Devices,... 1/2 12/9/2014 QIMS.E359313- Mounting Systems, Mounting Devices, Clamping Devices and Ground Lugs for Use with Photovoltaic Modules and Panels Trina Solar Ltd - TSM-215PA05, TSM-220PA05, TSM-225PA05, TSM- 230PA05, TSM-235PA05, TSM-240PA05, TSM-245PA05, TSM- 250PA05, TSM-255PA05, TSM-260PA05; TSM-215PA05.05, TSM-220PA05.05, TSM-225PA05.05, TSM- 230PA05.05, TSM-235PA05.05, TSM-240PA05.05, TSM-245PA05.05, TSM-250PA05.05, TSM-255PA05.05, TSM-260PA05.05; TSM-215PA05.08, TSM-220PA05.08, TSM-225PA05.08, TSM - Series Y N — 230PA05.08, TSM-235PA05.08, TSM-240PA05.08, TSM-245PA05.08, 200 TSM-250PA05.08, TSM-255PA05.08, TSM-260PA05.08; TSM-215PD05, TSM -220131305, TSM-225PD05, TSM-230PD05, TSM- 235PD05, TSM-240PD05, TSM-245PD05, TSM-250PD05, TSM- 255PD05, TSM-260PD05; TSM-215PD05.08, TSM-220PD05.08, TSM-225PD05.08, TSM- 230PD05.08, TSM-235PD05.08, TSM-240PD05.08, TSM-245PD05.08, TSM-250PD05.08, TSM-255PD05.08, TSM-260PD05.08. NRTL Listed PV Modules: Hanwha SolarOne: Models HSL60P6-PB-2-230% HSL60P6-PB-2- 235Q, HSL60P6-PB-2-240Q, HSL60136-1313-2-245Q, HSL60136-1313-2- 250Q, HSL60P6-PB-2-255% HSL60P6-PB-2-260Q, HSL60P6-PB-2- 265Q, HSL60136-1313-2-270Q; HSL60P6-PB-4-230Q, HSL60P6-PB-4-235Q, HSL60P6-PB-4-240% HSL60P6-PB-4-245Q, HSL60P6-PB-4-250% HSL60P6-PB-4-255Q, HSL60P6-PB-4-260% HSL60P6-PB-4-265Q, HSL60136-1313-4-270Q; may be followed by additional suffixes. Suniva Inc - OPTXXX-60-4-YYY; where XXX may be numbers 240 to 270 in increments of 5; where YYY may be 100; OPTXXX-60-4-YYY; where XXX may be numbers 235 to 265 in increments of 5; where YYY may be 1130. Series I N I N I A I Type 1 PV Modules Trademark and/or Tradename: "SNAPNRACK" Last Updated on 2014-08-26 Ouestions? Print this nage Terms of Use Page Toe ©2014 UL LLC When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment database for additional information regarding this product's certification. The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow -Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non - misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2014 UL LLC". http://database.ul.com/cgi-bin/XWrtempiate/LISEXT/1 FRAM E/showpage.htmI?name=QlM S.E359313&ccnshorttitle=Mounting+Systems,+Mounting+Devices,... 212 inverter fills a specific niche in the Aurora product line to cater for those installations producing between 5kW and 20kW. This inverter has all the usual Aurora benefits, including dual input section to process two strings with independent MPPT, high speed and precise MPPT algorithm for real-time power tracking and energy harvesting, as well as transformerless operation for high performance efficiencies of up to 97.1 %. The wide input voltage range makes the inverter suitable to low power installations with reduced string size. This outdoor inverter has been designed as a completely sealed unit to withstand the harshest environmental conditions. • Each inverter is set on specific grid codes which can be selected in the field Single phase output Dual input sections with independent MPPT, allows optimal energy harvesting from two sub -arrays oriented in different directions • Wide input range • High speed and precise MPPT algorithm for real time power tracking and improved energy harvesting • Flat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power range • Outdoor NEMA 4X rated enclosure for unrestricted use under any environmental conditions • RS -485 communication interface (for connection to laptop or datalogger) • Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI -DESKTOP Integrated Arc Fault Detection and Interruption (-A Version) BLOCK DIAGRAM OF PVI-5000-OUTD AND PVI-6000-OUTD FOR NORTH AMERICA INl.l1+1 I I I I MPPT,N1B,11B /r r� ry IIX/DCI BULK CAPS ' INI INl ; IN INl INI ; uNE GRiD I -LEE FILTER REIT IN121-) 1 N --------2--- , T .II.Ij} IN3� + ; ; DCA)Q LyTJ---11--I�1 IMM2 IN121+1+ IW IW ; IW ; IW IW ' RESIDUAL ECORENi ' STANDARDVERSION AVERSION STANDARD VERSION R85 +T/R ' E , • � � � -T/11 I E r REMOTE CONTROL•r}J ♦R r QO /D E OEIYL'11011 ✓° Al - ND ND c CONTRJL CIRCUT •-----------------------------------------------------------------------------• Renw,e caR[rd fvlRim naI avallade m-A,er9m PVI-5000/6000-OUTD-U 5 480 97 96,8 96,5 400 96,2 195,9 95,6 95,3 v 345 MPPT 95 Voltage 94,7 94,4 94,1 93,8 300 93,5 93,2 95, _ 92,9 250 92,6 10% 20% 30% 50% 75% 100% % of Rated Output Power PVI -5 000/6000-O U T D -U 5 100 99 98 97 96 95 94 93 92 — 250 Vdc — 345 Vdc 91 — aso Vdc 90 0 10 20 30 40 50 60 70 80 90 100 % of Rated Output Power PVI-5000/6000-OUTD-U 5 480 97 96,8 96,5 400 96,2 195,9 95,6 95,3 v 345 MPPT 95 Voltage 94,7 94,4 94,1 93,8 300 93,5 93,2 95, _ 92,9 250 92,6 10% 20% 30% 50% 75% 100% % of Rated Output Power Nominal Output Power W 5000 6000 Maximum Output Power W 5000 6000 Rated Grid AC Voltage V 208 240 277 208 240 277 Input Side (DC) Number of Independent MPPT Channels 2 2 Maximum Usable Power for Each Channel W 4000 4000 Absolute Maximum Voltage (Vmax) V 600 600 Start- Up Voltage (Vstart) V 200 (adj. 120-350) 200 (adj.120-350 ) Full Power MPPT Voltage Range V 200.530 200-530 Operating MPPT Voltage Range V 0.7xVstart-580 0.7xVstart-580 Maximum Current (ldcmaz) for both MPPT in Parallel A 36 36 Maximum Usable Current per Channel A 18 18 Maximum Short Circuit Current Limit per Channel A 22 22 Number of Wire Landing Terminals Per Channel 2 Pairs 2 Pairs Array Wiring Termination Terminal block, Pressure Clamp, AWG8-AWG4 Output Side (AC) Grid Connection Type 10/2W Split -0/3W 10/2W 10/2W Split -0/3W 10/2W AdjustableVoltage Range(Vmin-Vmax) V 183-228 211-264 244-304 183-228 211-264 244-304 Grid Frequency Hz 60 60 Adjustable Grid Frequency Range Hz 57-60.5 57.60.5 Maximum Current (lacmax) Awes 27 23 20 30 28 24 Power Factor > 0.995 > 0.995 Total Harmonic Distortion At Rated Power % <2 <2 Contributory Fault Current— Aa/Aw 36.25/25.63 36.5/25.81 31.75/22.45 36.25/25.63 36.5/25.81 31.75/22.45 Grid Wiring Termination Type Terminal block, Pressure Clamp, AWG8 - AWG4 Protection Devices Input Reverse Polarity Protection Yes Yes Over -Voltage Protection Type Varistor, 2 for each channel Varistor, 2 for each channel Pre start-up Riso and dynamic GFDI Pre start-up Riso and dynamic GFDI PV Array Ground Fault Detection (Requires Floating Arrays) (Requires Floating Arrays) Output Anti-Islanding Protection Meets UL 1741/IEE1547 requirements Meets UL 1741/IEE1547 requirements Over -Voltage Protection Type Varistor, 2 (L, - L2 / L, - G) Varistor, 2 (L - Lz / L, - G) Maximum AC OCPD Rating A 35 30 25 40 35 30 Efficiency Maximum Efficiency % 97.1 97.1 CEC Efficiency % 96 96.5 96.5 96 96.5 96.5 Operating Performance Stand-by Consumption Waves <8 < 8 Night time consumption Waves < 0.6 < 0.6 Communication User -Interface 16 characters x 2lines LCD display Remote Monitoring (1XRS485 incl.) AURORA -UNIVERSAL (opt.) Wired Local Monitoring (1xRS485 incl.) PVI-USB-RS485_232 (opt.), PVI -DESKTOP (opt.) Wireless Local Monitoring PVI -DESKTOP (opt.) with PVI-RADIOMODULE (opt.) Environmental Ambient Air Operating Temperature Range °F (°C) 13 to +140 (-25 to+60) 13 to +140 (-25 to +60) with derating above 122 (50) Ambient Air Storage Temperature Range °F (°Q -40 to 176 (-40 to+80) -40 to 176 (-40 to +80) Relative Humidity %RH 0-100 condensing 0-100 condensing Acoustic Noise Emission Level db (A) @1 m < 50 < 50 Maximum Operating Altitude without Derating NMI 6560 (2000) 6560 (2000) Mechanical Specifications Enclosure rating NEMA 4X NEMA 4X Cooling Natural Convection Natural Convection Dimensions (H x W x D) in (mm) 41.4 x 12.8 x 8.6 (1052 x 325 x 218) Weight Ib (kg) < 59.5 (27.0) < 59.5 (27.0) Shipping Weight Ib (kg) < 78 (35.4) < 78 (35.4) Mounting System Wall bracket Wall bracket Trade Size Kos: (tea x 1/21 Trade Size Kos: (tea x 1/2") Conduit Connections and (tea x 1-1/4, 3 places side, front, rear) and (tea x 1-1/4, 3 places side, front, rear) DC Switch Rating -(Per Contact) AN 25/600 25/600 Safety Isolation Level Transformedess (Floating Array) Transformerless (Floating Array) Safety and EMC Standard UL 1741, IEE1547, IEE1547.1, CSA -C22.2 N.107.1-01 , UL1998 UL1699B, FCC Part 15 Class B Safety Approval cCSA°, ZA,,, Warranty Standard Warranty years 10 10 Extended Warranty years 15&20 15 & 20 Available Models Standard - With DC Switch - Floating Array PVI-5000-OUTD-US PVI-6000-OUTD-US With DC Switch, Wiring box and Arc Fault Detector PVI-5000-OUTD-US-A PVI.6000-OUTD-US-A and Interrupter -All data is subject to change without notice '° Inverter can apply that much current - Breaker will open AURORA UNO 3 Power -One Renewable Energy Worldwide Sales Offices Country Name/Region Australia China (Shenzhen) China (Shanghai) India Japan Singapore Belgium /The Netherlands / Luxembourg France Germany Greece Italy Spain United Kingdom Dubai Israel Canada USA East USA Central USA West Asia Pacific Asia Pacific Asia Pacific Asia Pacific Asia Pacific Asia Pacific Europe Europe Europe Europe Europe Europe Europe Middle East Middle East North America North America North America North America Telephone +612 9735 3111 +86 755 2988 5888 +86 215505 6907 +65 6896 3363 03-4580-2714/+81-3-4580-2714 +65 6896 3363 +32 2 206 0338 +33 (0) 141796 140 +49 7641 955 2020 00 800 00287672 00 800 00287672 +34 91 879 88 54 +44 1903 823 323 +97150 100 4142 +972 0 3 544 8884 +1877 261-1374 +1877 261-1374 +1877 261-1374 +1 877 261-1374 Email sales.australia@power-one.com sales.china@power-one.com sales.china@power-one.com sales.india@power-one.com sales.japan@power-one.com sales.singapore@power-one.com sa les.belgium@power-one.com sales.france@power-one.com sales.germany@power-one.com sales.greece@power-one.com sales.italy@power-one.com sales.spain@power-one.com sales.uk@power-one.com sales.dubai@power-one.com sa les.israel@power-one.com sales.canada@power-one.com sales.usaeast@power-one.com sales.usacentral@power-one.com sales.usawest@power-one.com SNAPNRACK COMPOSITION L FOOT CAN BE MOUNTED IN ANY ORIENTATION SNAPNRACK CHANNEL NUT {� X 1' S.S. BOLT AND SNAPNRACK SPLIT WASHER STANDARD —� RAIL \ {� S.S. FLANGE NUT SNAPNRACK COMPOSITION ROOF FLASHING a' S.S. LAG SCREW ' 2,5' MINIMUM EMBEI SNAPNRACK L FOOT BASE (PLACED ON TOP OF SHINGLE) SEAL PENETRA UNDER BF APPROPRIATE ROOF RAFTER TY FLASHED L FOOT MOUNTING POINT FOR USE ON COMPOSITION ROOF SURFACES WITH LOW TO MODERATE TILT RAILS CAN BE LEVELED UP TO 3' USING UP TO TWO LEVELING SPACERS AS SHOWN IN 'SERIES 100 RAIL LEVELING' RFVISION ' NOTES - 5/16' LAG BOLTS MUST EMBED 2.5' INTO ROOF STRUCTURAL MEMBERS/RAFTERS - TORQUE ALL 5/16' HARDWARE TO THE FOLLOWING - SILVER S.S. 10-16 FT -LBS - BLACK S.S. 7-9 FT -LBS - RAILS CAN MOUNT TO EITHER SIDE OF L FOOT (UPSLOPE VS DOWNSLOPE) STEP 3, PLACE L FOOT ON TOP OF FLASHING AND TIGHTEN NUT STEP 2� SLIP FLASHING OVER L FOOT BASE STEP 1; BOLT L FOOT BASE TO ROOF WITH LAG BOLT o ROOF DECKING TYP. C� 1NSZ P��p,� 1aN i \ 0 ._S::ov1R 0RU E HY OFIS XPRES5" DESIGNER G. McPHEETERS SCALE DNS PART tt I PEN DETAIL O1 FLASHED L FOOT REV DISCLOSURE, OR USE TME0.EOf IS E%PRESSIY E vuo7,=, w,R,E- THEN'RmENPERMavoN DRAFTER G. MtPHEETERS DATE 120111 PEN-DO1 Of NAINSTRERM ENERGY CORP0R4TION. SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE # DESCRIPTION • SYSTEM SIZE: 6875W DC, 6000W AC • MODULES: (25) REC SOLAR: REC275TP • ALL WORK SHALL COMPLY WITH 2013 CEC, 2013 CBC AND CRC 2013 MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. SE SERVICE ENTRANCE SOLAR MODULES RAIL PV-1.0 COVER SHEET PV-2.0 SITE PLAN • INVERTER(S): (1) ABB: PVI-6000-OUTD-US-A (240 V) • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2013 CEC. • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH 2013 CEC. MAIN PANEL F8-1 ffq PV-3.0 LAYOUT • RACKING: SNAPNRACK SERIES 100 UL; FLASHED L FOOT. SEE PEN D01. • PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35. • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(E) AND 2012 IFC 605.11.2. SP SUB-PANEL STANDOFFS & FOOTINGS PV LOAD CENTER CHIMNEY re—] PV-4.0 ELECTRICAL PV-5.0 SIGNAGE PV-6.0 PLACARD • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. • 9.38 AMPS MODULE SHORT CIRCUIT CURRENT. • 14.65 AMPS DERATED SHORT CIRCUIT CURRENT (690.8 (a) & 690.8 (b)). SUNRUN METER s ATTIC VENT PM DEDICATED PV METER 0 FLUSH ATTIC VENT o PVC PIPE VENT \ p O INVERTER(S) WITH [INV] INTEGRATED DC DISCONNECT AND AFCI ® METAL PIPE VENT ® T-VENT 01: xCe AC QAC DISCONNECTS) SATELLITE DISH FIRE SETBACKS DC DISCONNECT(S) F7J A ` CB COMBINER BOX HARDSCAPE � G A NGO�� QQ►� P�NN� NO F -1 INTERIOR EQUIPMENT — LE2 SHOWN AS DASHED PL— PROPERTY LINE SCALE: NTS sunrun A AMPERE AC ALTERNATING CURRENT AFCI ARC FAULT CIRCUIT INTER R GILBERT CORREIA, C10, C46 AZIM AZIMUTH CA CL #750184 VICINITY MAP COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION - CUPERTINO APPROVED This set of laps ands specifications MUST be kept at the p p job site during construction. It unlawful to make any changes or alterations on same, or to deviate therefrom, without approval from the Building Official. The Stamping of this s ecif �_+' - --s SHALL NOT be to permit or to tbl� vii anion of any r . _ in,jnc-e cr State Law. T / �l��O� 3 — COMP COMPOSITION DC DIRECT CURRENT (E) EXISTING Q tip` EXT EXTERIOR FRM FRAMING �w cc INT INTERIOR,p LBW LOAD BEARING WALL `�� , MAG MAGNETIC 90 MSP MAIN SERVICE PANEL �1y1 O O �, (N) NEW NTS NOT TO SCALE ���,�of OC ON CENTER �� ��l -� %q PRE-FAB PRE-FABRICATED �\ ,� PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC TL TRANSFORMERLESS TYP TYPICAL V VOLTS W WATTS 2300 ZANKER ROAD, UNIT F, SAN JOSE, CA 95131 PHONE 408.746.3062 FAX 408.894.9294 _ Sorper-w >ark 4�11moo, F Stok�'s `1�e � 0 0 1 ?��� r— o O� Q CUSTOMER RESIDENCE: THEODORE FONG 22045 CREEKSIDE CT, CUPERTINO, CA, 95014 (650) 387-6530 APN #: 32639041 PTOJECT NUMBER: 02R-045FONG DESIGNER: MICHAEL SHAWGO 805.540.7670 DDRAFTER: SHEET COVER SHEET REV NAME DATE COMMENTS A REV: A 7/29/2015 I T22045Creekside Ct PAGE PV-1.0 SITE PLAN - SCALE = 1116" = 1'-0" I?,- ZZ e� (N) ARRAY AR -01 66'-7" r v r PL - FIRE (3' TYP) cu y Buildii i REVIEWED FOR CODE C W 9 Y Reviewed By: d LU W ry U ARRAY AR -02 D1 - AR -01 - SCALE: 3/16" = 1'-0" PITCH: 18° AZIM:102° D2 - AR -02 - SCALE: 3/16" = 1'-0" PITCH: 18° AZIM:102° ® 1-3'_1 -n r-rM0 � A^ f"Nfl 13'-2" ROOF TYPE ATTACHMENT ROOF HEIGHT ROOF EXPOSURE FRAME MATERIAL FRAME TYPE FRAME SIZE MAX FRAME SPAN OC SPACING ROOF EDGE ZONE MAX RAIL SPAN MAX RAIL OVERHANG DESIGN CRITERIA MODULES: AR -01 COMP SHINGLE FLASHED L FOOT. SEE PEN D01. TWO STORY ATTIC WOOD RAFTER 2 X 4 7' - 6" 24" YES 8'- 0" 2'- 8" REC SOLAR: REC275TP AR -02 COMP SHINGLE FLASHED L FOOT. SEE PEN D01. TWO STORY ATTIC WOOD RAFTER 2 X 4 T- 6" 24" YES 8'- 0" 2'- 8" MODULE DIMS: D1 - AR -01 - SCALE: 3/16" = 1'-0" PITCH: 18° AZIM:102° D2 - AR -02 - SCALE: 3/16" = 1'-0" PITCH: 18° AZIM:102° ® 1-3'_1 -n r-rM0 � A^ f"Nfl 13'-2" 26'-4 26'-4 1 3' 1 10'-11" L1. ROOF FRAMING DETAIL - SCALE: NTS RIDGE BOARD COLLAR TIE @ 48" OCA` 5/16" X 4.0" LAG SCREW. 1 BOLT PER PENETRATION COMP SHINGLE ROOF ---- SOLAR MODULE TOP PLATE 2X4 RAFTERS, 24" O.C. PURLIN LOAD BEARING WALL CUPERTIN Building Departure z REVIEWED FOR CODE COMPLIANCE Reviewed By: MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 0 PSF WIND SPEED: 110 MPH 3 -SEC GUST. LAG SCREWS: 5/16"x4.0": 2.5" MIN EMBEDMENT s u n r u ("k] GILBERT CORREIA, C10, C46 CA CL #750184 2300 ZANKER ROAD. UNIT F. SAN JOSE, CA 95131 PHONE 408.746.3062 FAX 408.894.9294 CUSTOMER RESIDENCE: THEODOREFONG 22045 CREEKSIDE CT, CUPERTINO, CA, 95014 TEL. (650) 387-6530 APN #'32639041 PROJECT NUMBER: 102R-045FONG DESIGNER: MICHAEL SHAWGO 805.540.7670 DRAFTER: DI SHEET LAYOUT REV: A 7/29/2015 PAGE PV -3.0 i I i I I i 1010 1 I I I I I I I I --- --- $' TYP -1 -�-TI 4- -IT-1--r-l-TTI 4- 4- I I 4- 26'-4 26'-4 1 3' 1 10'-11" L1. ROOF FRAMING DETAIL - SCALE: NTS RIDGE BOARD COLLAR TIE @ 48" OCA` 5/16" X 4.0" LAG SCREW. 1 BOLT PER PENETRATION COMP SHINGLE ROOF ---- SOLAR MODULE TOP PLATE 2X4 RAFTERS, 24" O.C. PURLIN LOAD BEARING WALL CUPERTIN Building Departure z REVIEWED FOR CODE COMPLIANCE Reviewed By: MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 0 PSF WIND SPEED: 110 MPH 3 -SEC GUST. LAG SCREWS: 5/16"x4.0": 2.5" MIN EMBEDMENT s u n r u ("k] GILBERT CORREIA, C10, C46 CA CL #750184 2300 ZANKER ROAD. UNIT F. SAN JOSE, CA 95131 PHONE 408.746.3062 FAX 408.894.9294 CUSTOMER RESIDENCE: THEODOREFONG 22045 CREEKSIDE CT, CUPERTINO, CA, 95014 TEL. (650) 387-6530 APN #'32639041 PROJECT NUMBER: 102R-045FONG DESIGNER: MICHAEL SHAWGO 805.540.7670 DRAFTER: DI SHEET LAYOUT REV: A 7/29/2015 PAGE PV -3.0 120/240 VAC SINGLE PHASE SERVICE OMETER #: M PG&E 1006095676 UTILITY GRID EXISTING 200A CMAIN BREAKER p (CENTER FED) CONDUIT SCHEDULE # EXISTING CONDUCTOR NEUTRAL PV MODULES 1 NONE (4) 10 AWG PV WIRE NONE 200A MAIN 2 ABB: PVI-6000-OUTD-US-A (240 V) (4) '10 AWG THHN/THWN-2 NONE (1) 8 AWG THHN/THWN-2 3 3/4" EMT OR EQUIV. (2) 8 AWG THHN/THWN-2 �. PANEL RUN M 6000 WATT INVERTER !! REC SOLAR: REC275TP FACILITY METER `Y (12) MODULES C; UPERTIN, LOADS 2 1 (1) STRING OF (12) MODULES =.jj P : -,a Departmet,. 3 3 O _ o--��a PV MODULES FACILITY JUNCTION BOX !! REC SOLAR: REC275TP FOR CODE Com, PILIANCE 35A PV 250V METER SOCKET DUAL MPPT TRACKERS STRING MIN RATED NEMA3R ! (13) MODULES REVIEWED BREAKER AS 125A CONTINUOUS & COMBINER & LOAD RATED DC -� (1) STRING OF (13) MODULES Reviewed By. FAR FROM MAIN 240V METER DISCONNECT AND AFCI BREAKER AS 200A, FORM 2S POSSIBLE CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4) 10 AWG PV WIRE NONE (1) 10 AWG BARE COPPER 2 3/4" EMT OR EQUIV. (4) '10 AWG THHN/THWN-2 NONE (1) 8 AWG THHN/THWN-2 3 3/4" EMT OR EQUIV. (2) 8 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 MODULE CHARACTERISTICS REC SOLAR: REC275TP 275 NAA OPEN CIRCUIT VOLTAGE 38.3 V MAX POWER VOLTAGE 31.5 V SHORT CIRCUIT CURRENT 9.38 A SYSTEM CHARACTERISTICS - INVERTER 1 SYSTEM SIZE 6875 W SYSTEM OPEN CIRCUIT VOLTAGE 541 V SYSTEM OPERATING VOLTAGE 410 V MAX ALLOWABLE DC VOLTAGE 600 V SYSTEM OPERATING CURRENT 17.48 A SYSTEM SHORT CIRCUIT CURRENT 23.45 A PER CODE: 690 52 NOTES TO INSTALLER: 1. 498 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE. 2. MAIN PANEL REPLACE (2) 20A 1 P BREAKERS AND (1) 40A 2P BREAKER WITH NEW 20/40/20A 1-2-1P QUAD BREAKER. 3. ADD 35A PV BREAKER TO MAIN PANEL. 6-12 AWG BARE 5/16"-18 SS BOLT COPPER WIRE SS SPLIT LOCK WASHER - (TORQUE TO 16 FT -LBS) SNAPNRACK \ GROUND LUG i BONDING CHANNEL NUT SS BONDING RAIL PINS NOTE: • ALL HARDWARE IS INCLUDED FROM MANUFACTURER • A MINIMUM OF ONE GROUND LUG IS TO BE INSTALLED ON EVERY CONTINUOUS ROW OF MODULES • GROUNDING LUG MAY BE INSTALLED IN EITHER RAIL CHANNEL • GROUNDING LUG MAY BE INSTALLED SO GROUND WIRE IS PARALLEL OR PERPENDICULAR TO RAIL • ENSURE SPLIT LOCK WASHER IS INSTALLED ON TOP OF COPPER WIRE SNAPNRACK GROUNDING SCALE: NTS A WARNING ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED LABEL LOCATION. DC DISCONNECT, INVERTER (PER CODE: CEC 690.35(F)) [To be used when inverter is ungrounded] AWARNING ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED LABEL LOCATION: DC DISCONNECT, INVERTER (PER CODE: CEC 690.35(F)) [To be used when inverter is ungrounded] AWARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: CEC 690.17(E)) AWARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION AC DISCONNECT, POINT OF INTERCONNECTION PER CODE: CEC 690.17(E), CB LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: CEC690.54) LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: CEC 705.12(D)(7)) [Not required if panelboard is rated not less than sum of ampere ratings of all overcurrent devices supplying it] CAUTION: SOLAR CIRCUIT LABEL LOCATION. MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES, AND CABLE ASSEMBLIES AT LEAST EVERY 10 FT, AT TURNS AND ABOVE/BELOW PENETRATIONS AND ALL COMBINER/JUCTION BOXES. (PER CODE: IFC605.11.1.4) LABEL LOCATION: DISCONNECT, POINT OF INTERCONNECTION (PER CODE. CEC690.13(B)) �AWARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM LABEL LOCATION: INVERTER, JUNCTION BOXES (ROOF), AC DISCONNECT (PER CODE: CEC690.13.G.3 & CEC 690.13.G.4) LABEL LOCATION: CONDUIT, COMBINER BOX (PER CODE. CEC690.31(G)(3)(4) & CEC 690.13(G)(4) ADHESIVE FASTENED SIGNS: • THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. • WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS, AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4 [NEC 110.21(B) FIELD MARKING]. • ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.1.31 LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE CEC 705.12(D)(4)) CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED LABEL LOCATION. WEATHER RESISTANT MATERIAL, DURABLE ADHESIVE, UL969 AS STANDARD TO WEATHER RATING (UL LISTING OF MARKINGS NOT REQUIRED), MIN %" LETTER HEIGHT ARIAL OR SIMILAR FONT NON -BOLD, PLACED WITHIN THE MAIN SERVICE DISCONNECT, PLACED ON THE OUTSIDE OF THE COVER WHEN DISCONNECT IS OPERABLE WITH SERVICE PANEL CLOSED. (PER CODE: CEC690.15, 690.13(B)) INVERTER 1 LABEL LOCATION: DC DISCONNECT, INVERTER (PER CODE: CEC690.53) CUPERTINC lit �(�ilding Departme, :j e REVIEWED SUR CODE COMP1_IA.�%'- (Reviewed E311