Loading...
15060147CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 10089 JUDY AVE CONTRACTOR: SOLARCITY PERMIT NO: 15060147 OWNER'S NAME: HONG JERRY 3055 CLEARVIEW WAY DATE ISSUED: 06/23/2015 O ER'S PHONE: 4083864948 SAN MATEO, CA 94402 PHONE NO: (650) 638-1028 Ed LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL E] COMMERCIAL ❑ License Class_ 0—(0,.,C INSTALL 23 ROOF TOP, FLUSH MOUNTED PV MODULES 0//Li//c. # 5 1 Q (5.98 KW) & ADD (N) 125 AMP SUB PANEL NEXT TO MAIN p0/ `` Contractor n 1[11d l'.-1 Date PANEL I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the Sq. Ft Floor Area: Valuation: $13500 performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this APN Number: 37507049.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXP IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating W 0 D PERMIT ISSUANCE OR to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save 0 D D INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities, j e costs, and expenses which may ac a against said City in conse e Date: Z� granting of this permit. Additig ly, t applicant understands and will comply with all non-point source reg a ion jthe Cupertino Municipal Code, Section 918. Signature Date (J6 RE-ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. ❑ OWNER-BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) I, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(a) should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cuperti o icipal Code, Chapter 9.12 and I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which thisOwner the Health & Safety Code, Sections 2550 X25 , and 25534. or authorized agent: fes' Date:() permit is issued. I certify that in the performance of the work for which this permit is issued, I shall ` not employ any person in any manner so as to become subject to the Worker's CONSTRUCTION LENDING AGENCY Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code, Section Licensed Professional 918. Signature Date CUPERTINO ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTNIENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 o buil6na�cupeaino.ora ICS 0 A PROJECT ADDRESS p' p1� ? C I Jar i 4 V g I�� APN # 9,S— — Q � — /) % v OWNERNAME , �, ` �t�c PHONE E-MAIL STREET ADDRESSCITY, STATE, Ip Lc�� Ca, q,50 FAX CONTACT NAME Marjan Javanmard PHONE650.477.6430 E-MAILmjavanmard@solarcity.com STREET ADDRESS 391 Foster City Blvd CITY, STATE, ZIP Foster City, CA 94404 FAX ❑ OWNER ❑ OWNER -BUILDER ❑ OWNER AGENT ❑ CONTRACTOR IN CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME SolarCity Corporation LICENSENUMBER888104 LICENSE TYPEC10 BUS. LIC #24440 COMPANY NAME SolarCity Corporation E-NIAILmjavanmard@solarcity.com FAX STREET ADDRESS 391 Foster City Blvd CITY, STATE, ZIP Foster City, CA 94404 ""650.477.6430 ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS. LIC # COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE USE OF SFD or Duplex ❑ Multi -Family STRUCTURE: ❑ CommeIcial PROJECT IN WILDLAND URBAN INTERFACE AREA ❑ Yes ❑ NO PROJECT IN FLOOD ZONE ❑ Yes ❑ NO 2 OLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PANELS: NUMBER OF PANELS/UMTS: � `� KILOWATTS (COMMERCIAL ONLY): �y TOTAL VALUATION C- I,� `I a DESCRIPTION OF WORK Installation (,ga) rooftop.flush mounted solar panel <. el?3) kW i By my signature below, I certify to each of the following: I am � pr� rty owner or auth agent to the prope owne ' al£ I have read this application and the information I have provided is correct. I ha" ea a Description of Work and ve ' it is accura o comply with all applicable local ordinances and state laws relating to building construction. I tltdri e r . resentatives of Cupertino to enter the above -identified property for inspection purposes. Signature ofApplicant/Agent: _ Date: /j S f� 5 SUPPLEMENT INFORMATION REQUIRED _ OrFICE USE ONLY �R-THE-COUNTER E❑ EXPRESS ❑ STANDARD U a ❑ LARGE c, ❑ MAJOR PVApp_2011.d6c revised 03116111 CITY OF CUPERTINO FEE ESTIMATOR — BUILDING DIVISION i0iADDRESS: 10089 JUDY AVE DATE: 06/23/2015 REVIEWED BY: MELISSA Meeh. lleni)il t'e'e APN: 375 07 049 BP#: 41'7*VALUATION: Other aleclr. Insp.=—I— $13,500 "PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY USE: SFD or Duplex Elec. Insp. PENTAMATION PERMIT TYPE: SOLAR -RE WORK INSTALL 23 ROOF TOP FLUSH MOUNTED PV MODULES 5.98 k & ADD N 125 AMP SUB SCOPE I PANEL NEXT TO MAIN PANEL NOTE: This estimate does not include fees due to other Departments (Le. Planning, Public Works, Fire, Sanuary Sewer Ds -145-00, D's t ' t t These ees are based on the relimina in ormation available and are only an estimate Contact the Dept or addn'l info, FEE ITEMS (Fee Resolution 11-053 Eff. 711/13) ;/feel). Plan (.7hec.•k 1'111170. Ptah Choc% Elec. Plan Check 0.0 hrs $0.00 Meeh. lleni)il t'e'e Numb. 1'e:rmil Feet: Elec. Permit Fee: ]EPERMIT Other aleclr. Insp.=—I— 011ier Plumb Inq).Li Other Elec. Insp. 0.0 hrs $48.00 ide<a11. lla.ip. /'ee: f'lunlb. hrsp. t ere. Elec. Insp. NOTE: This estimate does not include fees due to other Departments (Le. Planning, Public Works, Fire, Sanuary Sewer Ds -145-00, D's t ' t t These ees are based on the relimina in ormation available and are only an estimate Contact the Dept or addn'l info, FEE ITEMS (Fee Resolution 11-053 Eff. 711/13) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00� # $236.00 Alternative Energy System IPHOTOVRES Photovoltaic System Suppl. PC Fee: (j)Reg. Q OT 0.0 hrs $0.00 PME Plan Check: $0.00 125 amps $48.00 Electrical IBELEC200 Services Permit Fee: $0.00 Suppl. Insp. Fee -.(j) Reg. Q OT F0.0Thrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $48.00 Construction Tax Administrative Fee: ]ADMIN $45.00, 0 0 Work Without Permit? 0 Yes (j) No $0.00 Advanced Planning Fee: $0.00 Select a Non -Residential Building or Structure E) A Travel Documentation Fee: ITRA VDOC $48.00 Strong Motion. Fee: IBSEISMICR $1.76 Select an Administrative Item Bldg Stds Commission .Fee: IBCBSC $1.00 SUBTOTALS:' $143.76 $284.00 ._ TOTAL FEE w $427.76 Revised: 05/07/2015 ABBREVIATIONS I ELECTRICAL NOTES -] JURISDICTION NOTES A AMPERE AC ALTERNATING CURRENT BLDG BUILDING CONIC CONCRETE DC DIRECT CURRENT ECC EQUIPMENT GROUNDING CONDUCTOR (E) EXISTING EMT ELECTRICAL METALLIC TUBING FSB FIRE SET -BACK GALV GALVANIZED GEC GROUNDING ELECTRODE CONDUCTOR GND GROUND HDG HOT DIPPED GALVANIZED I CURRENT Imp CURRENT AT MAX POWER Isc SHORT CIRCUIT CURRENT kVA KILOVOLT AMPERE kW KILOWATT LBW LOAD BEARING WALL MIN MINIMUM (N) NEW NEUT NEUTRAL NTS NOT TO SCALE OC ON CENTER PL PROPERTY LINE POI POINT OF INTERCONNECTION PV PHOTOVOLTAIC SCH SCHEDULE S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT 1. THIS SYSTEM IS GRID-INTERTIED VIA A UL -LISTED POWER -CONDITIONING INVERTER. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. 3. A NATIONALLY -RECOGNIZED TESTING LABORATORY SHALL LIST ALL EQUIPMENT IN COMPLIANCE WITH ART. 110.3. 4. WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, A SIGN WILL BE PROVIDED WARNING OF THE HAZARDS PER ART. 690.17. 5. EACH UNGROUNDED CONDUCTOR OF THE MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY PHASE AND SYSTEM PER ART. 210.5. 6. CIRCUITS OVER 250V TO GROUND SHALL COMPLY WITH ART. 250.97, 250.92(B). 7. DC CONDUCTORS EITHER DO NOT ENTER BUILDING OR ARE RUN IN METALLIC RACEWAYS OR ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER ART. 690.31(E). 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY UL LISTING. 9. MODULE FRAMES SHALL BE GROUNDED AT THE UL -LISTED LOCATION PROVIDED BY THE MANUFACTURER USING UL LISTED GROUNDING HARDWARE. 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE BONDED WITH EQUIPMENT GROUND CONDUCTORS. FLASHING WILL BE PAINTED TO MATCH EXTERIOR LICENSE GENERAL NOTES I CA # 888104 1. ALL WORK TO BE DONE TO THE 2013 C-10 CALIFORNIA BUILDING CODE AND THE 2013 CALIFORNIA RESIDENTIAL CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY THE 2013 CALIFORNIA ELECTRIC CODE. MODULE GROUNDING METHOD: ZEP SOLAR I AHJ: Cupertino UTILITY: Pacific Gas and Electric Company CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: JB -9505337 CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP ZS Tile STile PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: THE SALE AND USE OF THE RESPECTIVE (23) REC # REC260PEZ SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PERMISSION OF SOLARCITY INC. FRONIUS # Primo 5.0 00 PREMISE OWNER: HONG, RICHARD 10089 JUDY AVE CUPERTINO, CA 95014 (408) 386-4948 VICINITY MAP HONG RESIDENCE 5.98 KW PV ARRAY PAGE NAME: COVER SHEET Building Department JUN 2 3 2015 REVIEWED FOR CODE COMPLIANCE ���--- Reviewed By. ZPLAN ECKED BY PLANNING'DEP CUPERTINO COMMIjNITY CF`/FLGP)MEN' F�" RTMENT EUILDINC; DIVISION - CUP;_RTINO APPROVED This set of plans a�-J saeclfications 11,1 ',,,ST 'Ce kept at the job site daring cocstr,,ction. It is .,n j%%ful to make any changes or alterations on same, or to deviate therefrom, witho e 5uilding Official. The g of this pla speci`cat.ons SHALL NOT e held to rcval of the violation sib mance or :v_ y PERMIT # BY DATE COMMENTS REV A I NAME I DATE COMMENTS * * * * Clark Fleming =;solarCity. 3055 Clearview Way SHEET: REV: DATE San Mateo, CA T. (650) 638-1028 F: (650638-1029 PV 1 6/22/2015 (868)—SOL—CITY (765-2489) www.solorcity.com COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS PV5 THREE LINE DIAGRAM -IPV1 L Cutsheets Attached BY DATE COMMENTS REV A I NAME I DATE COMMENTS * * * * Clark Fleming =;solarCity. 3055 Clearview Way SHEET: REV: DATE San Mateo, CA T. (650) 638-1028 F: (650638-1029 PV 1 6/22/2015 (868)—SOL—CITY (765-2489) www.solorcity.com PITCH: 18 ARRAY PITCH: 18 MP1 AZIMUTH: 180 ARRAY AZIMUTH: 180 MATERIAL: Spanish Tile STORY: 1 Story PITCH: 18 ARRAY PITCH: 18 MP2 AZIMUTH: 270 ARRAY AZIMUTH: 270 MATERIAL: Spanish Tile STORY: 2 Stories 9p / Re i FUFOR 13�O,s spa eo ety C �,t easy CFC \ F TOTAL ARRAY AREA (SF): 417 TOTAL ROOF AREA (SF): 4541 TOTAL ARRAY AREA IS a 9.18 PERCENT OF TOTAL ROOF AREA LEGEND (E) UTILITY METER & WARNING LABEL Ing INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS DC DC DISCONNECT & WARNING LABELS AC AC DISCONNECT & WARNING LABELS DC JUNCTION/COMBINER BOX & LABELS F DISTRIBUTION PANEL & LABELS Lc LOAD CENTER & WARNING LABELS ODEDICATED PV SYSTEM METER \ STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR -- CONDUIT RUN ON INTERIOR GATE/FENCE 0 HEAT PRODUCING VENTS ARE RED r, -- -I I1 ' l INTERIOR EQUIPMENT IS DASHED L_J Scale:SITE PLAN 3/32" Oil 10, N W E S CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE 108 NUMBER: JB -9505337 00 me■ix Vwncn. ucxavrnun: HONG, RICHARD HONG RESIDENCE uc�on: Clark Fleming ■ �; •� , MOUNTING SYSTEM: BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN 10089 JUDY AVE 5.98 KW PV ARRAY So�a�Ci}` 'w;"' .7 1. y ��� ZEP ZS Tile STile PART OTHERS OUTSIDE THE RECIPIENTS CUPERTINO, CA 95014 ORGANIZIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE MODULES (23) REC # REC26OPEZ 3055 Clearview Way SHEET: REV DATE PV 2 6/22/2015 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. PAS NAME (408) 386-4948 SITE PLAN San Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 INVERTER: FRONIUS # Primo 5.0 (888) -SOL -CITY (765-2489) www.solarcity.com A SIDE VIEW OF MPI NTS MP1 X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 72° 24" 72" 24" MOUNTING SYSTEM: PORTRAIT 4811 19TT PORTRAIT 48" TOP CHORD 2X8 @ 24" OC BOT CHORD 2X6 @16° OC ROOF AZI 180 PITCH 18 STORIES: 1 ARRAY AZI 180 PITCH 0 S -Tile (Cement) " DIA THREADED STUD & NUT ZEP LEVELING FOOT ZEP' TOP ARM ZEP ANTI -ROTATION PLATE M10 BOLTS MOUNTING BASE (E) TILE (E) ROOF DECKING (E) RAFTER " DIA STAINLESS STEEL LAG BOLT (2-j" EMBED, MIN) S I STANDOFF Scale: 1 1/2" = 1' INSTALLATION ORDER REMOVE TILE, LOCATE & MARK (1)1 RAFTER LOCATION -PLACE STANDOFF BASE & DRILL PILOT HOLES. - 2) �LTAN RAPER AROUND PILOT HOLE. SEAL PILOT HOLES AND BOTTOM OF ((3) STANDOFF WITH POLYURETHANE SEALANT. CL:AG:S:TA:N�DOFFASE INTORAFTER. 5 PLACE FLASHING AND ATTACH SEALING SPACER WITH SINGLE BOLT. (PLACE ZEP BAR. THEN INSTALL (6) LEVELING FOOT WITH BOLT & WASHER. SIDE VIEW OF MP2 NTS MP2 X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 72" 24" MOUNTING SYSTEM: IT BE DISCLOSED IN WHOLE PORTRAIT 48" 1 191 PART OTHERS OUTSIDE THE RECIPIENT'S TOP CHORD 2X8 @ 24" OC BOT CHORD 2X6 @16" OC ROOF AZI 270 PITCH 18 STORIES: 2 ARRAY AZI 270 PITCH 18 S -Tile (Cement) CUPERTIN0 Building Department 2 3 2015 REVIEWED FOR CODE COMPLIANCF Reviewed By: ��-- - CONFIDENTIAL —THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER: J B- 9505337 0 O PREMISE OWNER: DESCRIPTION: HONG, RICHARD HONG RESIDENCE DESIGN: Clark FlemingSolarCity. \\\ BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL OR IN 10089 JUDY AVE 5.98 KW PV ARRAY ►,� MOUNTING SYSTEM: IT BE DISCLOSED IN WHOLE ZEP ZS Tile STile PART OTHERS OUTSIDE THE RECIPIENT'S CUPERTINO, CA 95014 MULLS (23) REC # REC260PEZ 3055 CleoNew Way San Mateo, CA 94402 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE PAGE NAME: SHEET: REN. DATE INVERTER: FRONIus #Primo 5.0 SOLARCITY PERMSSIONEOFISOLARCITY INC.T THE WRITTEN 408 386-4948 () STRUCTURAL VIEWS PV 3 6/22/2015 29 (888) (SOL,CITY (765-2489) 5 w)w.solarcity.com VENT SPANNING DETAIL NTS i SOLAR PANEL SOLAR MODULE MOUNTING HARDWARE (SEE STANDOFF DETAIL) ROOFING MATERIAL PLYWOOD (E) RAFTER SPANNING PHOTOVOLTAIC MODULES OVER VENTS 2" MAX 2" MIN CLEAR SPAN DIAMETER __4,TO UNDERSIDE OF MODULE MINIMUM VENT HEIGHT IS 6" ABOVE THE SURFACE OF THE ROOF PER 2007 CPC SECTION 906.1. 6" MIN. VENT HEIGHT FROM TOP OF ROOFING MATERIAL VENT PIPE 2013 CPC 310.5 STATES 'NO FITTING, FIXTURE, AND PIPING CONNECTION, APPLIANCE, DEVICE, OR METHOD OF INSTALLATION THAT OBSTRUCTS OR RETARDS THE FLOW OF WATER, WASTES, SEWAGE, OR AIR IN THE DRAINAGE OR VENTING SYSTEMS IN AN AMOUNT EXCEEDING THE NORMAL FRICTIONAL RESISTANCE TO FLOW, SHALL BE USED UNLESS IT IS INDICATED AS ACCEPTABLE IN THIS CODE OR IS APPROVED IN ACCORDANCE WITH SECTION 301.1 OF THIS CODE." FROM THIS SECTION, IT IS CLEAR THAT MOUNTING SOLAR MODULES OVER A VENT IN A MANNER THAT WILL NOT HAVE A GREATER FRICTIONAL RESISTANCE TO AIR FLOW WOULD BE ACCEPTABLE. EQUATIONS: THE FRICTIONAL RESISTANCE TO FLOW IS DIRECTLY PROPORTIONAL TO THE AREA THAT THE AIR CAN FLOW THROUGH. IN THE VENT, THAT IS THE CROSS-SECTIONAL AREA OF THE VENT PIPE: Avent = 7T*R' WHEN THE AIR EXITS THE VENT, THE AREA IT HAS TO FLOW THROUGH IS THE CIRCUMFERENCE OF THE VENT TIMES THE VERTICAL DISTANCE BETWEEM THE VENT AND THE MODULE ABOVE (IN THIS CASE, WE ARE LEAVING THE DIAMETER BETWEEN THE TOP OF THE VENT AND THE BOTTOM OF THE PANEL). THIS METHODOLOGY ASSUMES THE WORST CASE SCENARIO OF MOUNTING THE MODULES HORIZONTALLY OVER THE VENT. IN ACTUALITY, THE MODULES WILL BE TILTED WHICH WILL OFFER MORE AREA FOR AIR TO FLOW THROUGH. Agap = C*CLEARANCE = (7I*D)*D = (7T*2*R)*(2*R) = 4*7T*R2 4*7T*R2 > 7T*R2 FROM THE EQUATIONS ABOVE, IT IS EVIDENT THAT MOUNTING THE MODULES IN THIS MANNER ALLOWS FOUR TIMES THE AMOUNT OF AIR FLOW ABOVE THE VENT THAN IN THE VENT ITSELF. VENT HEIGHT WILL BE A MINIMUM OF 6 INCHES ABOVE THE ROOF, OR THE MINIMUM VALUE ALLOWED BY LOCAL BUILDING CODE. MINIMUM CLEARANCE BETWEEN THE TOP OF THE VENT AND THE BOTTOM OF THE SOLAR MODULE GLASS SHALL BE AT LEAST THE DIAMETER OF THE VENT. IN THE DIRECTION OF THE SLOPE OF THE ROOF, THERE SHALL BE A GAP OF AT LEAST 1/2 INCH BETWEEN MODULES. THE ROOF SLOPE MUST HAVE A MINIMUM INCLINATION OF 10' OR THE PANELS MUST BE SLOPED AT A MINIMUM INCLINATION OF 10'. 7SYSTEM:B-9505337 00 PREMISE OWNER: CONFIDENTIAL -THE INFORMATION HEREIN JOB NUMHONG, RICHARD CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTIN10089 JUDY AVE NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEPe STile CUPERTINO, CA 95014 PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (23) REC # REC260PEZ SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: (408) 386-4948 PERMISSION OF SOLARCITY INC. FRONIUS # Primo 5.0 UPLIFT CALCULATIONS 06.22.2015 SolarCity. PV System Structural Version #46.4 Desian Software Project Information & Table Of Contents Risk Category: II PV System Type SolarCity SleekMount- Spanish Tile Roof Spanish Tile Roof Layers of Comp Roofing Roof Slope O.C. 24"" O Rafter S acin PV System Module Orientation Landscape and Portrait PV Module Area 409 sf 39" PV Module Width 66" PV Module Length SM Tile Standoff Attachment Hardware Reduced Ground/Roof Live/Snow Loads Ground Snow Load pg 0.0 psf ASCE Table 7-1 Surrounding Roof Snow 0.0 psf ASCE Eq: 7.4-1 ASCE E : 7.4-1 Roof Snow Over PV Modules 0.0 Psf Wind Design Criteria Wind Design Code ASCE 7-10 Partially/Fully Enclosed Method Wind Design Method V 110 mph Fig. 26.5-1A Basic Wind Speed C Section 26.7 Exposure Category Gable Roof Fig. 30.4-2A/0JC-5A/B Roof Style Mean Roof Height h 25 ft Section 26.2 Effective Wind Area 1 Module A i7.8 sf IBC 1509.7.1 Wind Pressure Calculation Coefficients Wind Pressure Exposure Kz 0.95 1.00 Table 30.3 i Section 26.8 Topographic Factor Kzt Kd 0.85 Section 26.6-1 Wind Directionality Factor NA Importance Factor I qh = 0.00256 (Kz) (Kzt) (Kd) (V^2) Equation 30.3- Velocity Pressure qh 24.9 pisf Ext. Pressure Coefficient (Up) GCp (Up) -0.88 Fig. 30.4-2A/B/C-5 11 Ext. Pressure Coefficient Down GC Down 0.45 Fa. 30.4-2A/B/C-5A/ Desicin Wind Pressure = qh GC Equation 30.4-1-' Wind Pressure Up P(up) psf Wind Pressure Downp(down)16.0 fi.0 sf Allowable Standoff S acin s X -Direction Y -Direction Max Allowable Standoff Spacing Landscape 72"39 24" NA Max Allowable Cantilever Landscape Not -Staggered Standoff Configuration Landscape Trib 20 sf Max Standoff Tributary Area 3 psf PV Assembly Dead Load W -PV Net Wind Uplift at Standoff T -actual -222 lbs Uplift Capacity of Standoff T -allow 446 lbs Standoff Demand/Capacity DCR 49.7% 48" 66" Max Allowable Standoff Spacing Portrait 19" NA Max Allowable Cantilever Portrait Not -Staggered Standoff Configuration Portrait 22 sf Max Standoff Tributary Area Trib 3 psf PV Assembly Dead Load W -PV -248 lbs Net Wind Uplift at Standoff T -actual 446 lbs Uplift Capacity of Standoff T -allow Standoff Demand/CapacL DCR 55.6% HONG RESIDENCE 5.98 KW PV ARRAY PAGE NAME UPLIFT CALCULATIONS Clark Fleming SHEET: REV: DATE: PV 4 6/22/2015 ;; GROUND SPECS - - — - MAIN PANEL SPECS - GENERAL NOTES_ -INVERTER SPECS-- MODULE SPECS LICENSE BOND (N) #8 GEC TO (N) GROUND ROD Panel Number: SC204OM200C Inv 1: DC Ungrounded INV 1 - (1) FRONIUS # Primo 5.0 LABEL: A - (23) REC ## REC260PEZ CA # 888104 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number: 1008803483 AFCI Inverter; 5000W, 240V, 97% PV FAodule; 260W, 236.6W PTC, MC4, 40mm, Black Frame, ZEP Enabled C-10 INV 2 Underground Service Entrance Voc: 37.8 Vpmax: 30.7 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER (E) 200A CENTER -FED MAIN SERVICE PANEL E 20OA/2P MAIN CIRCUIT BREAKER BRYANT Inverter 1 IND (N) 125A Load Center 1 200A/2P 4 3 FRONIUS DC- A A 30A/2P Primo 5.0 DC- MP 1: 1x13 (E) LOADS L1 zaov EGC -- - - - - ----------------------------------� I -------------- L2 DC+ I 30A/2P _ _ _ _ A 1 r N EGC/ GEC _ _ _ T N DG I 2 DC+ DC+ DG G MP 1: 1x10 I W 8 I I = I GND __ EGC - —-—------ - - - - -— Gc-----------------� -----------—--------- j (1) Conduit Kit; 3/4' EMT N I I EGC/GEC - Z Z 3OA/2P --— GEC --� TO 120/240V I SINGLE PHASE UTILITY SERVICE TO (E) LOADS I I dn9 oeRT 'V 10 '?3 3 F� FoR R� �ie�ea COOS 6y. C941A 1,q IVC, Voc* = MAX VOC AT MIN TEMP POI (2)Bumdy!BIT 2/0 Multr ble onnector, 2 Port - A (1)CUTLER-HA ¢WU30 Breaker, 30A 2P, 2 Spaces PVBACKFEfDBREAKER /� /-� D - (1) Ground Rod, 5/8"x-13% Copper - (1 ) CUTLER-HAMM R # BR230 Breaker, 30A 2P, 2 Spaces - (1) BLY d#BR4852Center2A, 0/24OV. NEMA 3R ��^i \ (2) AWG /10, PV Wire, 600V, Black VoC 535.18 VDC Isc = 9.01 ADC I, " f (1 ) AWG #10, Solid Bare Copper EGC Vmp = 399.1 VDC Imp= 8.5 ADC (1)AWG #10, THWN-2, Black -(1)AWG #10, THWN-2, Red (WFRL) (1) AWG #10, THWN-2, Red -(l)Conduit Kit; 3/4' EMT ® ��j' (1)AWG /10, THWN-2, Black O ff (1) AWG #10, THM-2, Red LL II�-LL(1)AWG 110, THWN-2, White Neutral Vmp =240 VAC Imp=N/A AAC IL"�-LL(i)AWG /10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=20.8 AAC (1)Conduit Kit; 3/4" EMT - (t) AWG #8, THWN-2,. Green .. EGC .- (1) AWG. /10, THWN-2, Black (WFRL) -(1)AWG #8,. THWN-2,. Green .. EGC/GEC- (1) Conduit. Kit;. 3/4' EMT (2) AWG #10, PV Wire, 60OV, Black Voc* = 411.68 VDC Is = 9.01 ADC O (1 )AWG #10, Solid Bare Copper EGC Vmp = 307 VDC Imp= 8.5 ADC (1 ) Conduit Kit; 3/4' EMT CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEnT OF ANYONE EXCEPT SOLARCITY INC., JOB NUMBER: J B— 9 5 0 5 3 3 7 O O PREMISE OWNER: HONG, RICHARD DESCRIPTION: HONG RESIDENCE DESIGN: Clark Fleming S o I a r C ty MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP ZS Tile STile 10089 JUDY AVE 5.98 KW PV ARRAY PART TO OTHERS THE RECIPIENTS ORGANIZATION, EXCEPT IDN CONNECTION WITH CUPERTINO, CA 95014 t MODULES 3055 Gearview Way Son CA5638-1029 THE SALEAND USE OF THE RESPECTIVE THE WRITTEN (23) REC # REC260PEZ PAGE NAME: SHEET: REV: DATE INVERTER: FRONIUS Primo 5.0 PEMRSSIONEOFISOLARCITY INCT 4O8 386-4948 THREE LINE DIAGRAM PV 5 6/22/2015 T:(650) 638-1028 F:(ateo, (888) -SOL -CITY (765-2489) www.solorcity.com Label Location: (C)(IC)(CB) Per Code: CRC R331.2 Label Location: (DC) (INV) Per Code: CEC 690.14.C.2 Label Location: (DC) (INV) Per Code: CEC 690.53 Label Location: (DC) (CB) Per Code: CEC 690.17 Label Location: (INV) Per Code: CEC 690.5(C) Label Location: (AC) (POI) Per Code: CEC 690.14.C.2 Label Location: (AC) (POI) Per Code: CEC 690.54 Label Location: (AC) Label Location: (DC) Per Code: CEC 690.17 Label Location: (POI) Per Code: CEC 705.12.D.7 Label Location: (POI) Per Code: CEC 690.54; CEC 690.17 Label Location: (D) (POI) Per Code: CEC 690.64.B.4 Label Location: (POI) Per Code: CEC 705.12.D.7 Label Location: (DC)(INV)(CB) Per Code: CEC 690.35(F) TO BE USED WHEN INVERTER IS UNGROUNDED 3 A4 ' V � FUR Cp0 �aBy QFC �p�/qyC \. F (AC): AC Disconnect (C): Conduit (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit (INV): Inverter With Integrated DC Disconnect (LC): Load Center (M): Utility Meter (POI): Point of Interconnection CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR `SI, 1f1j 3055 Clearview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED 4- San Mateo, CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, Label Set '0" 111 T:(650) 638-1028 F:(650) 638-1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE / SolarCity'l (888) -SOL -CITY (765-2489) www.solarcity.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. 'i; SolarCity ZepSolar .Zep System for tile roofs using replacement tiles QG�MPQT�6 �F N p�OMPP��e UL LISTED ON zepsolar.com ,.P Arm wud L _haq Fmt 'r-1. S m Tap A/r/m stud Top Arm k tiRote!i� iSY.e, i,l. • � = ftb tinp. bn. NJun!�np t Ani..Rotaeon %b!. 11 tt. neem Ta. Fuen�� andMaunL. ,{Bb Next -Level PV Mounting Technology names mrapn roar Jestk g!o ranrr patter i. Description • PV mounting solution for concrete tile roofs • Works with all Zep Compatible Modules • Zep System UL 1703 Class A Fire Rating for Type 1 and Type 2 modules • Auto bonding UL -listed hardware creates structual and electrical bond Specifications • Designed for pitched roofs • Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467 • Zep System bonding products are UL listed to UL 2703 Engineered for spans up to 72" and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices Attachment method UL listed to UL 2582 for Wind Driven Rain This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of Zep Solar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. 12 31 14 ZS for Replacement Tile Applications Cutsheet Rev 02.pdf Page: 1 of 2 '�k�SolarCity ZepSolar Components Replacement S -Tile Part No. 850-1435 Listed to UL 2703 Replacement W -Tile _ ___ParLNo.850-1437 Listed to UL 2703 Tile Roof Attachment Kit Part No. 850-1434 Listed to UL 2582 in Ground Zep Part No. 850-1172 Listed to UL 2703 and ETL listed to UL 467 zepsolar.com Interlock Part No. 850-1388 Listed to UL 2703 Next -Level PV Mounting Technology t Array Skirt, Grip, End Caps Part Nos. 500-0113, 850-1421,850-1460, 850-1467 Listed to UL 2703 I i Replacement Flat Tile Tj Part No. 850-1436 .[ Listed to UL 2703 f1 lilt, t CDS 0 0 C) O c/ l Q-11 _ DC Wire Clip Part No. 850-1448 Listed UL 1565 This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of Zep Solar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. 12 31 14 ZS for Replacement Tile Applications Culsheet Rev 02.pdf Page: 2 of 2 L a �G O 5 00 HIGH PERFORMANCE SOLAR PANELS REC PEAK REC Peak Enemy Z-LinkS r� soiaF panels are the perfect choice for building solar systems that combine long lasting product quality with reliable power output. REC combines high quality design and manufacturing standards to produce high performance solar panels with uncomoromisingquality. REC PEAK ENERGY Z -LINK SERIES 65.55 ±0.1 1.38 3? 0? EFFICIENCY YEAR PRODUCT WARRANTY YEAR LINEAR POWER OUTPUT WARRANTY oUr� US IMPORT DUTY FREE CERTIFICATION 1111111111110114 MECHANICALOATA 10 year product warranty. Dimensions: 65.55 x 39.02 x 1.57 in (1665 x 991 x 40 mm) cuL us 25 year linear power output warranty Area 1775ft2(1.65m ) LISTED (max, degression in performance of 0.7%p.a.)' 431bs Weight: 1 UL 1703, F ire rating: Type 1, CIassC g (9.5 kg) Note! All given specifications are subject to change without notice at anytime. REC is a leading global provider of solar energy solutions. With more than 15 years of experience, we offer sustainable, high performing ^ products, services and investments for the solar industry. Together with our partners, we create value by providing solutions that better I meet the world's growing energy needs. REC is headquartered in Norway and listed on the Oslo Stock Exchange (ticker: RECSOL). Our 1,600 employees worldwide generated revenues of USD 647 million in 2013. www.recgroup.com rr,UPERTINO Luilding Department I JUN 2 3 2015 `%R CODE COMPLIANCE I r Nomina I Operating Cell Temperature (NOCT) 45.7°C(t2°C) Temperature Coefficient of P, -0.40%/°C -- Temperature Coefficient of Vuc -0.27 %/°C Temperature-C—effiaen o sr 0.024 %/°C All measurements in inches ELECTRICAL DATA @ STC REC260PEZ Nominal Power-PMPP(Wp) 260 GENERAL DATA Cell Type: 60 REC PE multi -crystalline Watt Class Sorting- (Wp) /-S 3 strings of 20 cells with bypass diodes Nominal Power Voltage -V,,pP(V) 307 Glass: 0.125 in solar glass with anti -reflection Nominal Power Current -I,(A) 8.50 surface treatment BackSheet: Double layer highly resistant polyester Open CircuitVoltage- Voc(V) 37.8 Frame: Anodized aluminum (black) Short Circuit Current- Ix (A) 901 Zep G ro ove compatible Panel Efficiency(%) 158 Junction Box: IP67rated 0.156 in (12 AWG) solar cable, 2 x 4724 in The electrical characteristics are within -/-10% of the indicated values of Ir. Va andlo at standard Test conditions Values at standard test conditions STC(airmass AM 1.5, irradiance 1000 W7m',cell temperature 77'F (25'C)), (STC). Connectors: H4Amphenol At low irradiance of 200 W/m' (AM 1.5 & cell temperature 77°F (25°C)) at least 97% of the STC panel efficiency will be achieved. Origin: Made In Singapore ELECTRICAL DATA Nominal Power-P�P(Wp) 197 Operational Temperature: -40 .+185°F(-40..+85°0 Nominal PowerVoltage-V.(V) 29.0 Maximum System Voltage: 1000VUL Nominal Power Current -1,,(A) 6.81 Design Load: 50 lbs/ft2 (2400 Pa) long side Open Circuit Voltage - Voc(V) 35.7 301bs/ft2 (1436 Pa) short side Short Circuit Current- Isc (A) 7.24 Max Series Fuse Rating: 15A Nominal operatingcell temperature NOCT(800 W/m2,AM1.5, windspeed1 m/s, ambient temperature 68'F (20'C) Max Reverse Current: ISA CERTIFICATION 1111111111110114 MECHANICALOATA 10 year product warranty. Dimensions: 65.55 x 39.02 x 1.57 in (1665 x 991 x 40 mm) cuL us 25 year linear power output warranty Area 1775ft2(1.65m ) LISTED (max, degression in performance of 0.7%p.a.)' 431bs Weight: 1 UL 1703, F ire rating: Type 1, CIassC g (9.5 kg) Note! All given specifications are subject to change without notice at anytime. REC is a leading global provider of solar energy solutions. With more than 15 years of experience, we offer sustainable, high performing ^ products, services and investments for the solar industry. Together with our partners, we create value by providing solutions that better I meet the world's growing energy needs. REC is headquartered in Norway and listed on the Oslo Stock Exchange (ticker: RECSOL). Our 1,600 employees worldwide generated revenues of USD 647 million in 2013. www.recgroup.com rr,UPERTINO Luilding Department I JUN 2 3 2015 `%R CODE COMPLIANCE / Perfect Welding / Solar Energy / Perfect Charging FRONIUS PRIMO / The future of residential solar is here - Introducing the new Fronius Primo. / PC board / SnaplNverter / Wi-Fi&* / Sup"Flex / Smart Grid / Arc Fault Circuit replacement process mounting system interface Design Ready Interruptiou i SHIFTING THE LIMITS / With power categories ranging from 3.8 kW to 8.2 kW, the transformerless Fronius Primo is the ideal compact single-phase inverter for residential applications. The sleek design is equipped with the SnapINverter hinge mounting system which allows for lightweight, secure and convenient installation and service. / The Fronius Primo has several integrated features that set it apart from competitors including dual powerpoint trackers, high system voltage, a wide input voltage range and unrestricted use indoors and outdoors Other standar Featuresi an un peco us interface for seamless monitoring and datalogging, Arc Fault Circuit Interruption (AFCI), and Fronius's superb online and mobile platform Fronius Solar.web. The Fronius Primo is NEC 2014 ready and designed to adjust to future standards, offering a complete solution to code restrictions and technical innovations of tomorrow. TECHNICAL DATA FRONIUS PRIMO GENERAL DATA Dnm rr-rns (" rdth x height x depth) Weight Degree of protcctinn Night time consumption Inverter n,pology Cooling Installaiion Ambient operating temperature range I rrm:ued hr t ta}, DC c uu,(tir n terminals AC .......tion tenninals (.emlicates and compliance with standards PROTECTIVE DEVICES rf r I (r t r 1 I'. It I t is ,,, 11h J r tw, Inter r uptrr DC dGri,nnrc DC rr;er,r- polnr,ty f,rc�ir�eiw INTERFACES Wi f ,Ethernet/Serial 6 inputs or 4 digital inputs/outputs USN (A socket) 2. RS422 (R145 socket) Datalogger and Webserver STANDARD WITH ALL PRIMO MODELS <I W' Transformerleso Variable speed Ian Indoor and outdoor installati-i 40 131T ( 40,.. +55 C) 0 100 4. DC+ and 4x DC- uet+ [.nitro l i,, cold r (,olid stranded / tin <Iruided) t aluminum (,olid s(,an hcd) Sr e,v tennmals 12 6 AWG UL 1741-2010, UL1998 (for funcuons AFCI and isolation monitoring), IEEE 1547-2003, IEEE 1547.1-2003, ANSI/IEEE 062.41, FCC Part 15 A R N, NEC Article 690, C22. 2 Nn, 107-1 01 (September 2001) , OLl o99N Issue 2 2013, CSA TI I M 07 Issue 1 2013 *The term Wi-Fio is a registered trademark of the Wi-Fi Alliance. STANDARD WITH ALL PRIMO MODELS 1b� STANDARD WITH ALL PRIMO MODELS Wireless standard 602.11 b/gin / Fronius Solar-eb, SunSpec Modbus TCP, )SON / SunSpec tvlodbus KTU External relay controls Datalogging and/or updating via USN Fronius Solar Net, interface protocol AALI Included TECHNICAL DATA FRONIUS PRIMO INPUT DATA PRIMO 3.8-1 PRIMO 5.0-1 PRIMO 6.0-1 PRIMO 7.6-1 PRIMO 8.2-1 Recommended PV power (kWp) 3.0 - 6-0 }.Ati' 4.0 - 7.8 kW 4.8 - 9.3 kW 6.1 - 111,.,7 I,';'v o-6 I -> i L.1 td 7600 W 7900 W 240 380011V 5000 W Operating voltage range 7600 W 8200 W 150 - 600 V 208 18.3 A Max. in �. h.ge -..... .. ,.- 36.5 A 38.0 A ^`✓-1..,;; 240 15.8 A 20.8 A Nominal input voltage 410 V 420 V 420 V 420 V 420 V Admissable conductor size DC 40 A 50 A ` A 240 NI IT Voltage Range 200 480V 240 480 V 240 - 480V 250 480V 270 480 V Nurinber of T`IPPT 96.7 °% 969 % 96.9'%, 9 6. 9 %, 97.0 ",, OUTPUT DATA PRIMO 3.8-1 PRIMO 5.0-1 PRIMO 6.0-1 PRIMO 7.6-1 PRIMO 8.2-1 Max. outpw p,,;err 208 3800 W 5000 W 6000 W 7600 W 7900 W 240 380011V 5000 W 6000 W 7600 W 8200 W Max. continuous output current 208 18.3 A 24.0 A 28.8 A 36.5 A 38.0 A ^`✓-1..,;; 240 15.8 A 20.8 A 25.0 A 31.7 A 34.2 A Recommended OCPD/AC breaker size 208 2S-% 30 A 40 A 50 A 50A 240 20A 30A 35 A 40 A 45 A Max. F.ffidrucy 96.7 °% 969 % 96.9'%, 9 6. 9 %, 97.0 ",, CFC Efficiency 240 95 0 °: og 5 �� ,,, ,. , 9(>.5 Vit, Admissable conductor size AC AWG 14 AWG6 Grid connection '� _ 208 1240 Frequency 60 Hz Total harmonic distortion <5.014 Po-, faclar (n,s rp,,,r) 0.85 1 ind./cap ti 0 1 1941 v�c �4*? ��Z aBy a�F !S0 c �c1 J Perfect Welding / Solar Energy / Perfect Charging 3LQ WE HAVE THREE DIVISIONS AND ONE PASSION: SHIFTING THE LIMITS OF OSSIBILITY. / Whether welding technology, photovoltaics or battery charging technology - our goal is clearly defined: to be the innovation leader. With around 3,000 employees worldwide, we shift the limits of what's possible - our record of over 1,000 granted patents is testimony to this. While others progress step by step, we innovate in leaps and bounds. lust as we've always done. The responsible use of our resources forms the basis of our corporate policy. Further information about all Fronius products and our global sales partners and representatives can be found at www.fronius.corn Rev. 2.20.15 USA Fronius USA LLC 6797 Fronius Drive Portage, IN 46368 USA pv-support-usa@fronius.com www.fronius-usa.com