Loading...
1505002014 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 10413 MEADOW PL CONTRACTOR: SANCHEZ ELECTRIC, PERMIT NO: 15050020 INC OWNER'S NAME: DE GROOT MICHAEL AND KATJA TRUSTEE 5096 ENDENVIEW DR DATE ISSUED: 05/05/2015 OWNER'S PHONE: 4085697594 SAN JOSE, CA 95111 PHONE NO: (408)281-9854 ❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL E] COMMERCIAL E] ROOF MOUNTED SOLAR (26 MODULES) (6.37KW). License Class Lic. Contractor j'1G 2 Date G / I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the Sq. Ft Floor Area: Valuation: $27000 performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this APN Number: 34229041.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I rtify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITIIIN 180 DAYS OF PERMIT ISSUANCE OR to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save 180 DAYS FROM LAST CALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may acc . against said City in consequence of the Issued b T! Date: Y granting of this permit. Addition I , the applicant understands and will comply with all non -p nt source regul o per the Cupertino Municipal ode, Section 9.18. S /� � RE -ROOFS: Signature c �I/1i Date , All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. • ❑ OWNER -BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) I, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 offhe California Health & Safety Code, Sections 25505, 25533, and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(a) should I store or handle hazardous I have and will maintain a Certificate of Consent to self -insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Coqtlno Mun' r al Code, Chapter 9.12 and I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this 5, 255 d 25534. the Health & Safety Code, SeM-A Owner or authorized agent Date: permit is issued.ZV I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's CONSTRUCTION LENDING AGENCY Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued -(Sec. 3097, Civ C.) ` Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save ARCHITECT'S DECLARATION indemnify and keep harmless t City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section Licensed Professional 918. Signature Date CUPERTINO /5D 5 0o 6740 ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • buildingC�cupertino.org PROJECT ADDRESS / % f f 1 (I / _ /J i I J A / APN #Grj� 7J OWNERNAME PHO </ �% �jJC E-MAILLrFf STREET ADDRESS / f �'C� �v✓ �l CII YSTATE, ZIP J tJl'�r•i�tv [�G't J V 1 LI CONTACT NAME /n� //// bb V' �i�C lt PHO p` /J/_ E-MAIL P ✓ICGX�Z/7Y C STREET ADDRESS CITY , STATE, ZI FAX ❑ OWNER ❑ OWNER -BUILDER ❑ OWNERAGENT CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTORNAME / J / �LF' ��2� Z CC(JJJ LICENSE NUMBER - 6yy67 J LICENSE YPEIv BUS. LIC# COMPANY NAME / 7 E -MAI n FAX viG��%� STREET ADDRESS Ji, viG�v CITY, STATE, ZIP ` P /7(/ / PHONE 9 ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS. LIC # COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE USE OF ❑ SFD or Duplex 0 Multi -Family PROJECT IN WILDLAND PROJECT M ❑ Yes 0 No ❑ Commercial URBAN INTERFACE AREA ❑ Yes 2 J No FLOOD ZONE STRUCTURE: SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATJNG ❑ OTHER: FOR SOLAR PANELS. NUMBER OF PANELS/UNITS: g6 KILOWATTS (COMMERCIAL ONLY): / _ 3 7 rO TOTAL VALUATIO% D®0 N /r G� DESCRIPTION OF WORK By my signature below, I certify to each $the following: the property owner or authorized agent to act on the property owner's behalf. I have read this application and the information I hav p Ided is correc . I ave read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating �in conste2nauthorize representatives of Cupertino to enter the above-ide ifie property for inspection purposes. jr' 15' Signature of Applicant/Agent: Date: ST IPPLEMENTAL INFORMATION REQUIRED 3 oFFTCE usE oNLY ~' PVApp_2011.doc revised 03/16/11 CITY OF CUPERTINO W-9 FEE ESTIMATOR - BUILDING DIVISION ;ilech. Plan Cheek Tech. Pei�rnit l=ee: Ocher AIech. Insp. W ech. 1nspFee: Phurr[>. Plan Check Plumb. Permit Fee: Other Plumb Insp. Plumb. hasp. Fee: a Elec. Plan Check 0.0 hrs $0.00 Elec. Permit Fee: IEPERMIT Other Elec. Insp. 1 0.0 1 hrs 1 $48.00 L lec. hnp. I-ee: NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School Di.Qtrirt_ P/P_ )_ ThP.QP fPP.Q arP ha.wd an the nrelhninary Znfnrmat;nn avallahlP and arP nnly an P.wima/P_ Cnntart the nPnt fnr addn'l infn_ FEE ITEMS (Fee Resolution 11-053 Eff 711/13) 10413 MEADOW PL DATE: 05/05/2015 REVIEWED BY: SEAN IlaADDRESS: APN: BP#: G� 'VALUATION: $27,000 *PERMIT TYPE: Building Permit PLAN CHECK. TYPE: Alteration / Repair PRIMARY Multi -Family Dwelling USE: Buildina is >3 Stories 0 Yes (D No PENTAMATION SOLAR -RES PERMIT TYPE: WORK ROOF MOUNTED SOLAR 26 MODULES (6.37kW). SCOPE Electrical IBELEC200 Services ;ilech. Plan Cheek Tech. Pei�rnit l=ee: Ocher AIech. Insp. W ech. 1nspFee: Phurr[>. Plan Check Plumb. Permit Fee: Other Plumb Insp. Plumb. hasp. Fee: a Elec. Plan Check 0.0 hrs $0.00 Elec. Permit Fee: IEPERMIT Other Elec. Insp. 1 0.0 1 hrs 1 $48.00 L lec. hnp. I-ee: NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School Di.Qtrirt_ P/P_ )_ ThP.QP fPP.Q arP ha.wd an the nrelhninary Znfnrmat;nn avallahlP and arP nnly an P.wima/P_ Cnntart the nPnt fnr addn'l infn_ FEE ITEMS (Fee Resolution 11-053 Eff 711/13) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 © kW $572.00 Alternative Energy System IPHoTOVRES I Photovoltaic System Suppl. PC Fee: (j) Reg. Q OT 0.0 hrs $0.00 PME Plan Check: $0.00 F 200 amps $48.00 Electrical IBELEC200 Services Pen -nit Fee: $0.00 Suppl. Insp. Fee:Q Reg. Q OT 0.0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $48.00 Construction Ta.i: _FT Administrative Fee: 1ADMIN $45.00 0 G) Work Without Permit? 0 Yes Q No $0.00 Advanced Planning Fee: $0.00 Select a Non -Residential Building or Structure G 0 I Travel Documentation Fee: ITRAVDOC $48.00 Strom Motion Fee: IBSEISMICR $3.51 Select an Administrative Item Bld,g Stds Commission Fee:_ IBCBSC $2.00 t_" R S SUBTOTAL ...: :_..ff,. ..:..„,w.a. _.... $146.51 $620.00 ' ,r r TOTAL FEE ; $766.51 Revised: 04/01/2015 CUPERTINO SMOKE / CARBON MONOXIDE ALARMS OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • buildinola cupertino.ora PERMIT CANNOT BE FINALED UNTIL THIS CERTIFICATE HAS BEEN COMPLETED, SICrNFJJ, AND RETURNED TO THE BUILDING DIVISION PURPOSE This affidavit is a self -certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2016 CRC Section R314, 2016 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single-family and multi -family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds $1000.00, CRC Section R314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations: AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of the bedroom(s), X X On every level of a dwelling unit including basements X X Within each sleeping room X Carbon Monoxide alarms are not required in dwellings which do not contain fuel -burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. Power Supply: In dwelling units with no commercial power supply, alarm(s) may be solely battery operated. In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl space. Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2. An electrical permit is required for alarms which must be connected to the building wiring. As owner of the above -referenced property, I hereby certify that the alarm(s) referenced above has/have been installed in accordance with the manufacturer's instructions and in compliance with the California Building and California Residential Codes. The alarms specified below have been tested and are operational, as of the date signed below. nn tt Address: 0 1� 1 (" , 2 4, C -e Y- `-D Permit No. (5-0 S Oo 2 0 Specify Number of Alarms: # Smoke Alarms: 771 1 # Carbon Monoxide Detectors: r� I have read and agree to comply with the terms and conditions of this statement Owner (or Owner Agent's) Name: —I- C�nACI D.e 6Signature............ ��(�0"1 -..`.................. ...................................................................Date:,—'�"1 �............................................................................. Contractor Name: Signature.................................................................. Lic.# ......................................Date: Smoke and CO form.doc revised 12/15/16 C�S1� ti ItPF�. Owner Name Address WATER -CONSERVING PLUMBING FIXTURES OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 •FAX (408) 777-3333 • buildingCa�cupertino.orcg Permit No. l 5- O 5© Q O o 4 l 3 Kl _a d o vv ?In CSC +(%rl 1. Is your real property a registered historical site? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. X No Go to Question 2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its plumbing, installation of water -conserving plumbing fixtures is not technically feasible? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. ❑ The licensed plumber's certification has been provided to the Building Division. Skip the rest of the form and sign bottom of form. No Go to Question 3. 3. Is water service permanently disconnected for your building? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. Z No Go to Question 4. 4. Is your real property built and available for use or occupancy on or before January 1, 1994? ❑ No My real property is built and available for use or occupancy after January 1, 1994. Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. KYes My real property is built and available for use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101.8 apply. Check one of the three following statements and sign bottom of form.. - Please check ONE of the following: ❑ My property is a single-family residential real property. See Civil Code Section 1101.4. On and after January 1, 2014, building alterations or improvements shall require all non-compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non- compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements). My property is a multifamily residential real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water - conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). ❑ My property is a commercial real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). I, as the owner or owner's agent of this property, certify under penalty of perjury that non-compliant plumbing fixtures will be replaced prior to date specified above with water -conserving plumbing fixtures in accordance with Civil Code Sections 1101.1 through 110 1.8, the current California Plumbing Code and California Green Building Standards Code, and manufacturer's installation requirements, and that the water -conserving plumbing fixtures comply with the requirements as indicated in the table on the followina Aaae. Owner or Owner Agent's Signature: 1-,� Date: ( - I (::o - 2,01'7 1 Unon completing and signing this Certificate_ please the Building Division in order to final vour building hermit SB407 2015.doc revised 01/05/17 SYSTEM INFO GENERAL NOTES ffordable 6.37 KWDC 1. ALL WORK TO COMPLY WITH 2013 CALIFORNIA BUILDING CODE, 2013 CALIFORNIA GREEN BUILDING CODE. _ Solar Roof SOLD EQUIPMENT QTY FINVERTER: 2• ALL ELECTRICAL WORK TO COMPLY WITH 2013 CALIFORNIA ELECTRICAL CODE AND 2011 NATIONAL ELECTRICAL CODE. s Hanwha HSL60P6 PA-0 245 26 3. DC WIRING METHODS SHALL NOT BE INSTALLED WITHIN 10" OF THE ROOF DECKING OR SHEATHING EXCEPT WHERE COVERED BY THE PV MODULES AND `Energy efficiency above all" Enphase M215 60 2LL-S2X-IG 26 4. EQUIPMENT. 2013 CEC 690.31(E)(1) AN ACCESS POINT SHALL BE PROVIDED THAT DOES NOT PLACE THE GROUND LADDER OVER OPENINGS SUCH AS WINDOWS OR DOORS ARE LOCATED AT STRONGPOINTS CONSTRUCTIONLOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIO BOX 1778 MORGAN HILL, CA 95038 WIRE W/EOPP.O. DRAWING INDEX 5. CRC RIN SAS LIMBS WIRES y EJii"� H ALL EQUIPMENT AND ASSOCIATED CONNECTIONS OF INVERTERS, PV MODULES, PV SOURCE CIRCUITS, BATTERY CONNECTIONS, ETC. AND ALL Lic-C39, C46 #765156 PV1.0 COVER SHEET Design By: PV2.0 SITE PLAN ASSOCIATED WIRING AND INTERCONNECTIONS SHALL BE INSTALLED ONLY BY QUALIFY PERSONNEL. 2013 CEC 690.4 (E) MO 0 �J C �o�C PV3.0 ROOF DETAILS PLAN 6. ALL ELECTRICAL DEVICES AND EQUIPMENT OF ROOF AND OUTDOORS SHALL BE WEATHERPROOF AND UL LISTED. PV4.0 WIRING PLAN as ,� PV5.0 LABELS PLAN 7. ALL WIRING SHALL BE IN APPROVED RACEWAY, ALL CONDUCTORS SHALL BE STRANDED COPPER WITH THHN/THWN INSULATION.` 8. BY .--_-- SMOKE DETECTORS SHALL BE INSTALLED IN ACCORDANCE WITH 2013 CRC R314 PRIOR TO FINAL INSPECTION, MBP Solar Design CODE COMPLIANCE 9. CARBON MONOXIDE DETECTOR SHALL BE INSTALLED IN ACCORDANCE WITH 2013 CRC SECTION R315 PRIOR TO FINAL INSPECTION. & Consulting LLC, BUILDING CODE RESIDENTIAL CODE F01 DATA SHEETS FROM MANUFACTURERS (supplied on 8x11_ sheets) � Any questions please contact: ELECTRICAL CODE ENERGY CODE • • Hanwho HSL60P6-PA-0-245TW RTMEN Enphose Energy M215-60-2LL-S2X-IG ,�-� pEPA Pedro Nombe to DEPARTMENT CODE Unirac SM Rocking System 9 (650) 771 3189 FIRE 2011 NATIONAL ELECTRICAL CODE pEVE`OPtitE' Cvt,ERTINO QUICKMOUNT PV Flashed L Foot Kit tUf.11TY ipN - OMS pnomberto@mbpsolar.com p1NG ;f�D"Onk atthg LOCATION MAP d /� 8p� i� ke ani A �tifu� toa m v'late DE GROOT RESIDENCE - Salcm4 ve a -—�-- �— r' a Salem Avc !t w n 104 13 MEADOW PL CU 014 PERT( DE RO T Sane, g CO�,�.(, O DtC'ai ;,te dorm rations n S,; �din9 0 me N a cR w �n9es °� atte a ro'4a1 from ,ons SNAt l PP eC, Ica:. Ph ne 408) 589-7U 94 kdegroolome Com of the �iotatt =.•efrom, Without of this Pian and sP ro�a �d a Stevens Creek [31vd Cupertino fid Ste a StamP'n ermit °r to be an �rPmance °r State to P City SYMBOL LEGEND: PROJECT ctie uny : he`d . ns of any ��C1► ATTIC vENTs Stevens Creek Blvd Longdown Rd Granada AveAvc m " ��� Pf0V1S J �� MECHANICALS o , PLUMBING VENTS 6.37 KWDC PV SYSTEM Hermosa Ave �P`jE ��y—(71 CHIMNEY I J- A, �Ce I Y , Y.—tR,- 4 ; O Ave w" I omita Ave O f PER SOLAR MODULES s 15'1015 CITY PERMIT ANDY O � ? io M ��,r sq� T QJ CSFM 3' SETBACKS Y co y y C_yi R, W f WN S 9ve VU l` A CL o m " C A r v > r ©AT� D CONDUIT UNDER THE EAVE THROUGH THE This drawings represent ideas, designs, arrangements, plans and specifications which are propietary 10413 Meadow PI Dolores Ave P " kA�A CONDUIT ON ROOF METER to MBP Solar Design & Consulting PLC,. All Builders, Contractors, and Ve11rC/ A a � // •, v /� D NG ELECTRIC MAIN SERVICE PANEL AI Professionals are responsible for verification Of all COndiIIODS. AlCalde Rd Santa Paula Ave �� �• QT ADDITIONAL ELECTRIC 0 dimens ons and details indicated In T. 1 METER METER these drawings. No part of these McClellan a Monta Vista High School r LIr1C0 suBPANEL SUB plans, specifications, and or details can be reproduced in any manner o 3 Ranch Preserve Elementary1 INVERTER DC DISCO) EI without the written consent of MBP (INTEGRATED El Solar Design & Consulting LLC.. Cj G AC DISCONNECT Qa °'9a DC DISCONNECT COVER n. S �Jr'dn9-�:I JUNCTION BOX ,J6 COMBINER BOX SHEET Deep CIM Golf Course C-FFICE ROOF ATTACHMENTS �r�nervnc �. . �a COPY N TS �. 'oa � No: 1411 G� v c CDh1nf��s PV 1 no �,�c� A I I I 28'-0" I I (N) INVERTER (E) MAIN PANEL #1 & METER (TO BE UPGRADED) I (E) MAIN PANEL #2 & METER FOR ANEX BUILDING (TO BE UPGRADED) ; 1 1 I L- _ _ Fire AC ess Point ARRAY 1 T CSFM DRIVE— SETBACKS CSFM SETBACKS A2MUTH 182• FROM NORTH ROOF PITCH BREAK • (E) GA E • • FROM H I82• CSFM SETBACKS FROM NORTH Q'O ROOFPl BREAK_ (M) CITY ATTACHMENT POINTS 4 TZ m MAX I ARRAY2J Fir Access Point IJ I� O 0 W C 1 1 I I -0" I I \ffordablIle Solar Roofs Energy efficiency above all, P.O. BOX 1778 MORGAN HILL, CA 95038 Lic-C39, C46 #765156 Design By: MBP Solar Design & Consulting LLC, Any questions please contact: Pedro Nomberto (650) 771-3189 pnomberto@mbpsolar.com DE GROOT RESIDENCE 10413 MEADOW PL CUPERTINO, CA 95014 KATJA DE GROOT Phone (408) 569-7594 kdegmot®me com SYMBOL LEGEND: PROJECT ATTIC VENTS D MECHANICAL &0 6.37 KWDC PV SYSTEM PLUMBING VENTS CHIMNEY o* b— ae• ai SOLAR MODULES 041152015 CiT PERMIT ANDY CSFM 3'SETBACKS CONDUIT UNDER THE EAVE This drawings represent Ideas. THROUGH THE ATTIC designsarrangements. plans and Specifications which are propletary CONDUIT ON ROOF to MBP Solar Design 8 Consulting O LLC,. All Builders, Contractors, and ELECTRIC METER Professionals are responsible for MAIN SERVICE PANEL AI verification of all Conditions, ADDITIONAL ELECTRIC dimensions and details Indicated In METER these drawings No part of these SUB plans, specifications. and or details SUBPANEL can be reproduced in any manner INVERTER awithout the written consent of MBP (INTEGRATED DC DISCO) Solar Design 8 Consulting LLC,. AC DISCONNECT DC DISCONNECT SITE JUNCTION BOX r' PLAN COMBINER BOX ROOF ATTACHMENTS 0 Stift IN Ts 0eulo6�c On•YIg IIF: PV2.0 ARF,�AY 1 CSFM SETBACKS 0 0 DE GROOT RESIDENCE 0 0 0 0 1 0 1 0 Phone. (408) 589-7594 kdegrootQme.com PROJECT. SYMBOL LEGEND: ATTIC VENTS I' I 0 0 MECHANICAL & a PLUMBING VENTS j AZIMUTH 182° FROM NORTH t--,= 0 0P-0--t: 0i iC.i a o0 (48) QTY ATTACHMENT POINTS @ 72" OC MAX 1 ROOF LAYOUT SCALE: 1/8" = 1' 3'-0R -r7 ROOF ATTACHMENT DETAILS (COMP. SHINGLE): e MOUNTING CLI �i Ain.3 UNIr CALUM. -- L"RAC SOLAR PANED SUPPORT RAIL LA -\ COMPOSITION_ 3' CSFM SETBACKS PITCH BREAK C,0 o AZIMUTH 182° CSFM SETBACKS FROM NORTH / / z 0 0 ROOF PITCH BREAK 0 0 0 0 0 0 0 0 Ir u u o O C C O O I I 31-011 0 "Wr Maximum roof load: 3 Ibs/ft2 Maximum point load: 31.98 lbs/attachment Model: Hanwha HSL60P6-PA-0-245 Weight: 46.3 Lbs Width: 39.37 Inches Length: 65.04 Inches `1�2x4 RAFTER C24 -OC TW Snf x a' $$ IAG eO INTO RAFTEw51110LT MN. NETRATION WI RODE SE�Nr�. i1COMP ROOF - UNIRAC ATTACHMENT DETAIL SCALE 1/2' = 1' 1r MAX 7Y OG YAX IY MAX TIP.f–RAL AUK- I —1 ' TV. RAl ' I f ■■■■■■ ■■■■■�I ■■■■■■ ■■■■■11 - —as Mw"M -Me. miam g :*I CUP, Tr. CUP, np. UNIRAC RAIL & ACCESORIES : SLOT FOR T-90LT W w•iuiR oVJzw T UAOT FOR I �� rTc»Nom zseo SIAI raI Mid Clamp End Clamp w i� A�Gd Ott -, Rail Splice Rails affordable Solar Roofs "Energy efficiency above a!!" P.O. BOX 1778 MORGAN HILL, CA 95038 Lic-C39, C46 #765156 Design By: r stto. °�.:�► I / MBP Solar Design & Consulting LLC, Any questions please contact: Pedro Nomberto (650)771-3189 pnomberto@mbpsolar.com DE GROOT RESIDENCE 10413 MEADOW PL CUPERTINO, CA 95014 KATJA DE GROOT Phone. (408) 589-7594 kdegrootQme.com PROJECT. SYMBOL LEGEND: ATTIC VENTS I' I If 6.37 KWDC PV SYSTEM MECHANICAL & o O PLUMBING VENTS CHIMNEY Iw a x.rrn. 00 D" By SOLAR MODULES P 04'15:'2015 CITYY PERMIT ANDY CSFM 3'SE78ACK5 CONDUIT UNDER THE EAVE This drawings represent ideas, g P THROUGH THE ATTIC designs, arrangements, plans and specifications which are propietary CONDUIT ON ROOF to MBP Solar Design & Consulting LLC,All Builders, Contractors. and ELECTRIC METER O Professionals are responsible for MAIN SERVICE PANEL MAIN Verification Of all conditions. ADDITIONAL ELECTRIC M ® dimensions and details indicated in METER these drawings. No part of these SUB Plans, specifications, and or details SUBPANEL can be reproduced in any manner INVERTER Q without the written Consent of MBP (INTEGRATED DC DISCO) Solar Design & Consulting LLC.. AC DISCONNECT DC DISCONNECT © ROOF LAYOUT AND JUNCTION BOX COMBINER BOK DETAILS PLAN ROOF ATTACHMENTS O Hgst Nn o,. sods N.T.S. O.r+Mrc PV3.0 BI-DIRECTIONAL _ ffordable 1 PHASE, 3WIR Solar Roofs 1 PHASE, 3 WIRE (2) 20A DPB 120/240 V LOCATED FARTHEST "Energy efficiency above all" PHOTOVOLTAIC ARRAY FROM MSP BRANCH CIRCUIT 1 = 13 MODULES JUNCTION Fff1(a l Fff� I BOX • • • BRANCH CIRCUIT 2 = 13 MODULES • • • ENPHASE AC ENGAGE CABLE THWN-2 IN L1 = BLACK, L2 = RED, N = WHITE 3/4" EMT G = GREEN AWG #10 EGC = AWG #6 BARE CU L1 = BLACK Record low ternp L2 = RED BRANCH CIRCUIT #1, Isc = 11.7 A N = WHITE Max AC Output Current G = GREEN BRANCH CIRCUIT #2, Isc = 11.7 A 240 V Hanwha HSL60P6-PA-0-245 UL1703 Power 245 W 37.2 Voc, 29.7 Vmp, 20 Vnom 8.8 Isc, 8.25 Imp 600 V, UL E42728, NEMA 1,2,3,4,4x,6,12,13 Enphase M215-60-2LL-S2x-IG 240V UL 1741, NEMA 3R, IEEE 1547 Nom Voltage 240 V Max Current 0.9 A NEW, IF NO EXISTING GROUNDING ELECTRODE Max Branch AC required conductor ampacity (0.9) (13) (1.25) =14.63A AWG #10, derated ampacity: (35)(0.71)(1) = 24.85A 24.85A > 14.63A , therefore AC wire size is valid. Combined System AC required conductor ampacity (0.9) (26)(1.25) = 29.25A AWG #8, derated ampacity: (50)(0.71)(1) =35.5A 35.5A > 29.25A , therefore AC wire size Is valid. 200 A MAIN DISCONNECT NEW MIN 225 A RATED MAIN SERVICE PANEL ETHERNET CABLE TO BROADBAND ROUTER ENVOY COMMUNICATIONS GATEWAY (E) OUTLET Notes: 1. All racking grounded using thin plated direct burial lay -in ground lugs using stainless steel hardware and throughout array with #6 solid copper ground wire to bond all racking in exposed areas. Modules can be grounded with #10 AWG bare copper wire. WEEB Clips can be used to bond mounting Rails to PV Modules per AHJ. 2. Point of Connection made inside meter panel at dedicated breaker. 'This Point of Connection" complies with CEC art. 690.64 (B) and specifically "the sum of the amp ratings feeding the buss bar" = 200A + 30A - (120% x 225A Main Buss Bar Rating) 3. AC Breaker used as AC Disconnect, 4. All wires to be sized and derated for its location. 5. Inverters and Modules shall be constructed following NEC guidelines. 6. Maximum voltage shall not exceed 600Vdc 7. All equipment shall be bonded to EGC. 8. The EGC shall be irreversibly bonded to the GEC 9. EGC sized per NEC 690.45 and NEC 250.122 10. Only copper conductors shall be used. 11. PV Circuits are ungrounded and conform to NEC 690.35 12. Inverter internal DC Switch suitable as Disconnecting Means per NEC 690.13 13.120V/15A AC GFCI Outlet for Secure Power Supply and 120V/10A Switch with indicating light. Install adjacent to inverter in outdoor rated Nema 3R enclosure per manufacturer recommendations when applicable. P.O. BOX 1778 MORGAN HILL, CA 95038 Lic-C39, C46 #765156 Design By: MBP Solar Design & Consulting LLC, Any questions please contact: Pedro Nomberto (650) 771-3189 pnomberto@mbpsolar.com Branch Circuits 2 Modules per Branch 13,13 Number of Inverters 26 Record low ternp 327 KATJA DE GROOT Max AC Output Current 23.4 A Operating AC Voltage 240 V Operating AC Power 5616 W Operating AC Frequency 60 Hz Max OCP D Rating 30A NEW, IF NO EXISTING GROUNDING ELECTRODE Max Branch AC required conductor ampacity (0.9) (13) (1.25) =14.63A AWG #10, derated ampacity: (35)(0.71)(1) = 24.85A 24.85A > 14.63A , therefore AC wire size is valid. Combined System AC required conductor ampacity (0.9) (26)(1.25) = 29.25A AWG #8, derated ampacity: (50)(0.71)(1) =35.5A 35.5A > 29.25A , therefore AC wire size Is valid. 200 A MAIN DISCONNECT NEW MIN 225 A RATED MAIN SERVICE PANEL ETHERNET CABLE TO BROADBAND ROUTER ENVOY COMMUNICATIONS GATEWAY (E) OUTLET Notes: 1. All racking grounded using thin plated direct burial lay -in ground lugs using stainless steel hardware and throughout array with #6 solid copper ground wire to bond all racking in exposed areas. Modules can be grounded with #10 AWG bare copper wire. WEEB Clips can be used to bond mounting Rails to PV Modules per AHJ. 2. Point of Connection made inside meter panel at dedicated breaker. 'This Point of Connection" complies with CEC art. 690.64 (B) and specifically "the sum of the amp ratings feeding the buss bar" = 200A + 30A - (120% x 225A Main Buss Bar Rating) 3. AC Breaker used as AC Disconnect, 4. All wires to be sized and derated for its location. 5. Inverters and Modules shall be constructed following NEC guidelines. 6. Maximum voltage shall not exceed 600Vdc 7. All equipment shall be bonded to EGC. 8. The EGC shall be irreversibly bonded to the GEC 9. EGC sized per NEC 690.45 and NEC 250.122 10. Only copper conductors shall be used. 11. PV Circuits are ungrounded and conform to NEC 690.35 12. Inverter internal DC Switch suitable as Disconnecting Means per NEC 690.13 13.120V/15A AC GFCI Outlet for Secure Power Supply and 120V/10A Switch with indicating light. Install adjacent to inverter in outdoor rated Nema 3R enclosure per manufacturer recommendations when applicable. P.O. BOX 1778 MORGAN HILL, CA 95038 Lic-C39, C46 #765156 Design By: MBP Solar Design & Consulting LLC, Any questions please contact: Pedro Nomberto (650) 771-3189 pnomberto@mbpsolar.com DE GROOT RESIDENCE 10413 MEADOW PL CUPERTINO, CA 95014 KATJA DE GROOT Phone: (408) 569-7594 kdegroot@me.com PROJECT SYMBOL LEGEND: ATTIC VENTS p I Its 6.37 KWDC PV SYSTEM MECHANICAL& 0 PLUMBING VENTS CHIMNEY I.Iw � R.,vfa■ r-� 0*1r.. oA. Di SOLAR MODULES I�-J' 04.n 512011 5 CITY PERMIT ANDY CSFM 3'SETBACKS Y1L.GLLJ P This drawing represent resent ideas, CONDUIT UNDER UNDER: THE EAVE THROUGH THE ATTIC designs, arrangements. plans and specifications which are propietary CONDUIT ON ROOF to MBP Solar Design & Consulting O LLC,All Builders, Contractors, and ELECTRIC METER Professionals are responsible for MAIN SERVICE PANEL PAIN Verification of all Conditions. ADDITIONAL ELECTRIC dimensions and details indicated in METER these drawings. No part of these SUB plans, specifications, and or details SUBPANEL can be reproduced in any manner INVERTER Q without the written consent of MBP (INTEGRATED DC DISCO) Solar Design & Consulting LLC,. AC DISCONNECT DC DISCONNECT ED WIRING JUNCTION BOX JB PLAN COMBINER BOX ® ROOF ATTACHMENTS 0 a $eIMt NS.& PV4.0 NEC 690.5(C) - AT THE INVERTER AND/OR GROUND FAULT INDICATOR LOCATION (AND ALL BATTERY LOCATIONS IF APPLICABLE): NEC 690.52 - ON AC DISCONNECT POINT OF INTERCONNECTION: NEC 690.14(C)(2), 690.15 - ON AC/DC DISCONNECT: NEC 690.17 - AT JUNCTION BOX, COMBINER BOXES AND AC/DC DISCONNECTS: NEC 705.12(D)(7) - BY BREAKER AT DISTRIBUTION EQUIPMENT: NEC 705.10 - AT SERVICE EQUIPMENT LOCATION: NEC 690.35(F) - UNGROUNDED PV SYSTEMS ONLY AT EACH JUNCTION BOX, COMBINER BOX, DISCONNECT AND DEVICE WHERE THE UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE: CSFM - DC CONDUIT EVERY 10' INTERIOR/EXTERIOR Notes: 1. All Signs shall be red background and white lettering. For outdoor installations they shall be engraved phenolic plastic type and suitable for their environment. 2. Labels on raceways and other equipment shall be reflective, weather resistant, and suitable for the environment. This sheet shall be attached to all submitted PV plans. 3. Marking is required on all interior and exterior DC conduit, raceways, enclosures, cable assemblies, and junction boxes to alert the Fire Service to avoid cutting them. 4. Marking should be placed on all interior and exterior DC conduit, raceways, enclosures, and cable assemblies, every 10 feet, at turns and above and/or below penetrations and all DC combiner and junction boxes. 5. Letter size minimum- 3/8" 6. Main Service Panel and Inverter - Install a permanent Phenolic plaque at the service entrance equipment denoting all electrical power sources and their location on front of the service equipment. A plaque shall be located on the inverter with the location of the Main Service equipment if no within sight. Minimum Size 6" x 6" (CEC 705.10). *%,ff_ordable Solar Roofs "Energy efficiency above all" P.O. BOX 1778 MORGAN HILL, CA 95038 Lic-C39, C46 #765156 Design By: iii.. MBP Solar Design & Consulting LLC, Any questions please contact: Pedro Nomberto (650) 771-3189 pnomberto@mbpsolar.com DE GROOT RESIDENCE 10413 MEADOW PL CUPERTINO, CA 95014 KATJA DE GROOT Phone: (408) 569-7594 kdegrootQme com PROJECT: SYMBOL LEGEND: ATTIC VENTS ED Y!! 6.37 KWDC PV SYSTEM MECHANICAL& 0 O PLUMBING VENTS CHIMNEY Ywr d IOMiolr r� oe1e BBT SOLAR MODULES 1 04/15:Ro15 CITYY PERMIT ANDY CSF . 3TBACKS E S s represent ideas, This drawing � CONDUIT: UNDER THE EAVE THROUGH THE ATTIC designs, arrangements, plans and specifications which are propietary CONDUIT ON ROOF to MBP Solar Design & Consulting LLC,All Builders, Contractors, and ELECTRIC METER O Professionals are responsible for MAIN SERVICE PANEL AI Verification Of all Conditions, ADDITIONAL ELECTRIC dimensions and details indicated in METER these drawings. No part of these SUB plans. specifications, and or details SUBPANEL Can be reproduced in any manner INVERTER Q without the written consent of MBP (INTEGRATED DC DISCO) Solar Design & Consulting LLC.. AC DISCONNECT DC DISCONNECT LABELS JUNCTION BOX F PLAN COMBINER BOX ROOF ATTACHMENTS O Fiwrir �e� Scdc N.T.S. PV5.0