Loading...
15010115-VOIDCITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 10676 AMULET PL CONTRACTOR: SOLARCITY PERMIT NO: 15010115 OWNER'S NAME: RAO PADAKANDLA K AND YADGIRKAR HEMA 3055 CLEARVIEW WAY DATE ISSUED: 01/22/2015 OWNER'S PHONE: 4087338870 SAN MATEO, CA 94402 PHONE NO: (650) 638-1028 LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL E] COMMERCIAL ❑ FO © INSTALL 20 PANEL, ROOFTOP FLUSH MOUNTED 5.2 KW License Clas Lic. # Contractor Date 1 I hereby aff m that I am licensed under the provisions of hapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Sq. Ft Floor Area: Valuation: $10000 1 have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this APN Number: 32643060.00 Occupancy Type: -plamit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES -IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITHIN 180 PERMIT ISSUANCE OR to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save 180 DAYS FR AST ALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the Issued by: Date: granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. RE -ROOFS: Signatur Date ( T�_ All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. ❑ OWNER -BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) 1, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(a) should I store or handle hazardous I have and will maintain a Certificate of Consent to self -insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and I have and will maintain Worker's Compensation Insurance, as provided for by the Health & Safety Code, Sections 25505, 25533, and 25534. Section 3700 of the Labor Code, for the performance of the work for which this Owner or authorized agent: ' Date: permit is issued. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's CONSTRUCTION LENDING AGENCY Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section Licensed Professional 9.18. S ignature Date Patricia Garcia From: Krishna Rao [krishna_rao_ca@yahoo.ca] Sent: Thursday, August 27, 2015 10:16 PM To: Patricia Garcia Cc: Building Subject: Re: Building permit #15010115 Expiry Hi Patricia, I would like to cancel it. Thanks, Padakandla Rao On Aug 27, 2015, at 9:29 AM, Patricia Garcia <PatGAcupertino.org> wrote: Padakandla Rao, Please let me know if you want to cancel this permit or wish to pay to keep it open until you start project down the way. Kindly, PatrtCial (�a lCial City of Cap�iA& -BuGa t n, Dept. 408 777 3228 patg@cul2ertino.org From: Krishna Rao [mailto:krishna rao ca(ayahoo.ca] Sent: Thursday, August 27, 2015 8:37 AM To: Building Subject: Building permit #15010115 Expiry 0, I would like to inform you that solar panel installation project requested in building permit application #15010115 was never started. We do not intend to start this project anytime soon. Thanks, Padakandla Rao 10676 Amulet Place Cupertino, CA 95014 Ph: 408-733-8870 CUPERTINO ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building a,cupertino.org PROJECT ADDRESS APN # U ^ OWNERNAME �; C J P ON� ^ E-MAIL STREET ADDRESS ffY, STATE ZIP , V FAX (� i CONTACT NAME PHONE E-MAIL ET ADDRESS �TT�Y, S ATE, ZIP FAX V CA C) ❑ OWNER ❑ OWNER -BUILDER ❑ OWNER AGENT %CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT C�NTRACTORNAME LWrE LIC�t'NSE�YPE BUS. LIC lJ COMPANY NAME E-MAIL FAX So I �l ct STREET ADDRESS Ij CITY STATE Z C G o ` ` PHONE U ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS. LIC A COMPANY NAME E-MAIL FAX STREET ADDRESS - - CITY, STATE, ZIP PHONE USE OF FPSFD or Duplex ❑ Multi -Family PROJECT IN WILDLAND PROJECT IN ❑ Commercial URBAN INTERFACE AREA ❑ Yes ❑ NO FLOOD ZONE ❑ Yes ❑ No STRUCTURE: �FDSOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION El SOLAR WATER HEATING El OTHER: FOR SOLAR PANELS: NUMBER OF PANELS/UNITS: GL(� KILOWATTS (COMMERCIAL ONLY): TOTAL VALUATIO# C UG DESCRIPTION OF WORK L (ao)S By my signature below, I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. I have read this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local aut ordinances and state laws relating t buildi construction. I h ' representatives of Cupertino to enter the above -identified property for inspection purposes. Signature of Applicant/Agent; Date: S PPLEMENTAL rNFoAMATION REQUIRED � `❑ �OVERTHZrI�OIJN�'ER s �i ,r, y j"a � a'' �'+ r,. E"x' �"❑ r�'JCERESS ���r �.�� Nr ift Rg"n 1s 1 g� 45„ e r4F' _ ❑ ki BARGE S� i 4 rdr F t s -sb .. �, �+' 4 td a7 ''- lr+"''ytr X35 's § . y2.,E.� c�. ❑ MAJOR � Ea.. �x.c ' �`x.,.� PVApp_2011.doc revised 03/16/11 CITY OF CUPERTINO ,��,���' 1� Vl F F.QTTMATnR — RITII.DING DIVISION NOTE: This estimate does not include fees due to outer Departments (i.e. manning, u—, —--- __.. _ _ Contact the Dept for addn'1 info. These District, eta). ees are Qaseu on the reuiusnu• FEE ITEMS (Fee Resolution 11-053 E . 7ff 11113) ,r�ch, I'lart Check Phinth. Plan � --__ _._ ____________ MISC ITEMS LaiADDRESS: 10676 amulet pl DATE: 01/22/2015 REVIEWED BY: Mendez PE�: APN: BP#: *VALUATION: j$10,000 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY SFD or Duplex PME Plan Check: PENTAMATION SOLAR -RES PERMIT TYPE: i USE: Permit Fee: WORK I install 20 panel, rooftop flush mounted 5.2 kw 0.0 hrs SCOPE NOTE: This estimate does not include fees due to outer Departments (i.e. manning, u—, —--- __.. _ _ Contact the Dept for addn'1 info. These District, eta). ees are Qaseu on the reuiusnu• FEE ITEMS (Fee Resolution 11-053 E . 7ff 11113) ,r�ch, I'lart Check Phinth. Plan � --__ _._ ____________ MISC ITEMS Other flow, Praq't $0.00 PE�: Alternative Energy System IPHOTOVRES Photovoltaic System Suppl. PC Fee: (E) Reg. Q OT 0.0 NOTE: This estimate does not include fees due to outer Departments (i.e. manning, u—, —--- __.. _ _ Contact the Dept for addn'1 info. These District, eta). ees are Qaseu on the reuiusnu• FEE ITEMS (Fee Resolution 11-053 E . 7ff 11113) e•• �••••�••�•• �• FEE -�•� -•- ^-- QTY/FEE --__ _._ ____________ MISC ITEMS Plan Check Fee: $0.00 1 # $236.00 Alternative Energy System IPHOTOVRES Photovoltaic System Suppl. PC Fee: (E) Reg. Q OT 0.0 hrs $0.00 PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Feer Reg. Q OT 0.0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 C"Onstro'cti n Tax: A,4132inistrafive Fee: O Work Without Permit? 0 Yes (E) No $0.00 Advanced PlannipZ Fee: $0.00 P= Select a Non -Residential Building or Structure O O cel Do,.-wrwnlaiif)n Strom Motion Fee: IBSEISMICR $1.30 Select an Administrative Item Bld Stds Commission Fee: IBCBSC $1.00 SUBTOTALS: $2.30 $236.00 TOTAL FEE: $238.30 Revised: 01/06r2ui5 ABBREVIATIONS ELECTRICAL NOTES � JURISDICTION NOTES A AMPERE AC ALTERNATING CURRENT BLDG BUILDING CONIC CONCRETE DC DIRECT CURRENT EGC EQUIPMENT GROUNDING CONDUCTOR (E) EXISTING EMT ELECTRICAL METALLIC TUBING FSB FIRE SET—BACK GALV GALVANIZED GEC GROUNDING ELECTRODE CONDUCTOR GND GROUND HDG HOT DIPPED GALVANIZED I CURRENT Imp CURRENT AT MAX POWER Isc SHORT CIRCUIT CURRENT kVA KILOVOLT AMPERE kW KILOWATT LBW LOAD BEARING WALL MIN MINIMUM (N) NEW NEUT NEUTRAL NTS NOT TO SCALE OC ON CENTER PL PROPERTY LINE POI POINT OF INTERCONNECTION PV PHOTOVOLTAIC SCH SCHEDULE S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT 1. THIS SYSTEM IS GRID—INTERTIED VIA A UL—LISTED POWER—CONDITIONING INVERTER. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. 3. A NATIONALLY—RECOGNIZED TESTING LABORATORY SHALL LIST ALL EQUIPMENT IN COMPLIANCE WITH ART. 110.3. 4. WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, A SIGN WILL BE PROVIDED WARNING OF THE HAZARDS PER ART. 690.17. 5. EACH UNGROUNDED CONDUCTOR OF THE MULTIVRE BRANCH CIRCUIT WILL BE IDENTIFIED BY PHASE AND SYSTEM PER ART. 210.5. 6. CIRCUITS OVER 250V TO GROUND SHALL COMPLY WITH ART. 250.97, 250.92(B). 7. DC CONDUCTORS EITHER DO NOT ENTER BUILDING OR ARE RUN IN METALLIC RACEWAYS OR ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER ART. 690.31(E). 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY UL LISTING. 9. MODULE FRAMES SHALL BE GROUNDED AT THE UL—LISTED LOCATION PROVIDED BY THE MANUFACTURER USING UL LISTED GROUNDING HARDWARE. 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE BONDED WITH EQUIPMENT GROUND CONDUCTORS. LICENSE GENERAL NOTES CA # 888104 1. ALL WORK TO BE DONE TO THE 2013 C-10 CALIFORNIA BUILDING CODE AND THE 2013 CALIFORNIA RESIDENTIAL CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY THE 2013 CALIFORNIA ELECTRIC CODE. MODULE GROUNDING METHOD: * I AHJ: Cupertino UTILITY: Pacific Gas and Electric Company CONFIDENTIAL — THE INFORMATION HEREIN SGB NUMBER: JB -9504301 00 CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: THE SALE AND USE OF THE RESPECTIVE (20) REC # REC260PEZ SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PERMISSION OF SOLARCITY INC. ABB # PVI-3.6—OUTD—S—US—Z—A FLASHING WILL BE PAINTED TO MATCH EXTERIOR PREMISE OWNER: RAO, KRISHNA 10676 AMULET PL CUPERTINO, CA 95014 (408) 733-8870 0.�F.1-TICE COPY PLOT PLANS CHECKED BY DATE i- 2z - COMMUNITY DEVELOPMENT DEPARTVEMT BUILDING DRASION -CUPERTINO APPROVED , This set of plans and specifications MUST be kept at the job site during construction. It is unlawful to make any changes or alterations on same, or to deviate therefrom, without approval from the Building Official. The Stamping of this plan and specifications SHALL NOT be held to permit or approval of the violation of any provisions Ordinance or State Law. 6Y DATE PERMIT NO. d VICINITY MAP DESCRIPTION: RAO RESIDENCE 5.2 KW PV ARRAY PAGE NAME: COVER SHEET ANNING DEP CUPERTINO INDEX PV1 COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV41�ck lF ALCULATIONUJPER T INO PV 5: :Tk� 4 NE DIAGRA Cuts l ts`. Nched u0d'n9 Department (REVIEWED, rOR CODE COMPLIANCE I=reviewed By REV BY DATE COMMENTS REV A NAME DATE COMMENTS DESIGN: Dana Irving SHEET: REV: DATE: PV 1 1/15/2015 40 =SolarCity. 3055 Clearview Way San Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 (888)—SOL—CITY (765-2489) www.solarcity.com Froi CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: J B-9 5 0 4 3 01 00 CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC.,MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: THE SALE AND USE OF THE RESPECTIVE (20) REC # REC260PEZ SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PERMISSION OF SOLARCITY INC. ABB # PVI-3.6—OUTD—S—US—Z—A RAO, KRISHNA 10676 AMULET PL CUPERTINO, CA 95014 (408) 733-8870 PITCH: 20 ARRAY PITCH: 2O MP1 AZIMUTH: 180 ARRAY AZIMUTH: 180 MATERIAL: Comp Shingle STORY: 1 Si PITCH: 20 ARRAY PITCH: 2O MP2 AZIMUTH: 90 ARRAY AZIMUTH: 9O MATERIAL: COMID Shinale STORY: 1 Si I Fr-.FNn RAO RESIDENCE Dana Irving 'IQ �\�� SolarCity. 5.2 KW PV ARRAY .-i�, AMA" 3055 Clearview Way PAGE NAME: SHEET: REV: DATE: T: (650) San Mateo, CA 94 0638-1029 SITE PLAN PV 2 1/15/2015 (88e)-soL-CITY(765-2489)www.solarcity.com O (E) UTILITY METER & WARNING LABEL Ian INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS FDC DC DISCONNECT & WARNING LABELS AC AC DISCONNECT & WARNING LABELS O DC JUNCTION/COMBINER BOX & LABELS CupERTIN DISTRIBUTION PANEL &LABELS building Depat-neR .E LOAD CENTER &WARNING LABELS DEDICATED PV SYSTEM METER REVIEWED FOR CODE C0MPLIAN 0 STANDOFF LOCATIONS Reviewed By l�srf . __ CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR — GATE/FENCE O HEAT PRODUCING VENTS ARE RED L ='J INTERIOR EQUIPMENT IS DASHED SITE PLAN N TOTAL ARRAY AREA (SF): 363 TOTAL ROOF AREA (SF): 3275 Scale: 3/32" = 1' W E TOTAL ARRAY AREA IS a 11.07 01' 10' 21' PERCENT OF TOTAL ROOF AREA s DESIGN: RAO RESIDENCE Dana Irving 'IQ �\�� SolarCity. 5.2 KW PV ARRAY .-i�, AMA" 3055 Clearview Way PAGE NAME: SHEET: REV: DATE: T: (650) San Mateo, CA 94 0638-1029 SITE PLAN PV 2 1/15/2015 (88e)-soL-CITY(765-2489)www.solarcity.com B SIDE VIEW OF MP2 NTS (� MP2 X -SPACING X CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 72" 24" -d SEAL PILOT HOLE WITH POLYURETHANE SEALANT. PORTRAIT 48" 20" RAFTER C.J. 2X4 @ 24" OC 2X6 @16" OC ROOF AZI 90 PITCH 20 STORIES: 1 ARRAY AZI 90 PITCH 20 Comp Shingle PV MODULE 5/16" BOLT WITH LOCK & FENDER WASHERS ZEP LEVELING FOOT ZEP ARRAY SKIRT ZEP COMP MOUNT C ZEP FLASHING C (E) COMP. SHINGLE (E) ROOF DECKING 5/16" DIA STAINLESS STEEL LAG BOLT WITH SEALING WASHER (2-1/2" EMBED, MIN) (E) RAFTER CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, VATH04JT THE WRITTEN PERMISSION OF SOLARCITY INC. S 1 STAN DOFF JOB NUMBER: JB -9504301 00 MOUNTING SYSTEM: Como Mount Twe C REC # REC260PEZ NVERTER: ABB # PVI-3.6—OUTD—S—US—Z—A INSTALLATION ORDER X -SPACING X -CANTILEVER (1) LOCATE RAFTER, MARK HOLE LOCATION, AND DRILL PILOT HOLE. LANDSCAPE 72" 24" (2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. PORTRAIT 48" 20" (3) INSERT FLASHING. ROOF AZI 180 PITCH 20 STORIES: 1 ARRAY AZI 180 PITCH 20 Comp Shingle (4) PLACE MOUNT. (5) INSTALL LAG BOLT WITH SEALING WASHER. L6,—)F—VELING FOOT WITH BOLT & WASHERS. RAO, KRISHNA 10676 AMULET PL CUPERTINO, CA 95014 (408) 733-8870 60 m '-4 9'-9" 5-1' (E) LBW A SIDE VIEW OF MP1 NTS MP1 X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 72" 24" PORTRAIT 48" 20" RAFTER C.J. 2x6 @ 24" OC 2x6 @24" OC ROOF AZI 180 PITCH 20 STORIES: 1 ARRAY AZI 180 PITCH 20 Comp Shingle DESCRIPTION: RAO RESIDENCE 5.2 KW PV ARRAY PACE NAME: STRUCTURAL VIEWS CUPERTINO .b }3uildi ng DeDartmero E JAN 2 2 2015 REVIEWED FOR CGDE CC)PWPOANCE- REwiewed BV Dana Irving SHEET: REV: DATE: PV 3 1/15/2015 SolarCity. 3055 Clearview Way San Mateo, CA 94402 T:(65O) 638-1028 F:(65O) 638-1029 (888)—SOL—CITY (765-2489) www.solarcity.com CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER: JB -9504301 00 MOUNTING SYSTEM: Como Mount TVDe C (20) REC # REC260PEZ INVERTER: ABB # PVI-3.6-0UTD-S-US-Z-A PREMISE OWNER: RAO, KRISHNA 10676 AMULET PL CUPERTINO, CA 95014 (408) 733-8870 UPLIFT CALCULATIONS 01.15.2015 SolarCityPV System Structural Version #42.2 Desian Software Project Information & Table Of Contents Risk Category: II PV System Type SolarCity SleekMount- Comp Roof Comp Roof Layers of Comp Roofing 2 Roof Slope 20° Rafter Spacing24" 0. C. PV System Module Orientation Landscape and Portrait PV Module Area 355 sf PV Module Width 39" PV Module Length 66" Standoff Attachment Hardware Cornp Mount Type C Reduced Ground/Roof Live/Snow Loads Ground Snow Load pg 0.0 psf ASCE Table 7-1 Surrounding Roof Snow 0.0 psf ASCE Eq: 7.4-1 Roof Snow Over PV Modules 0.0 psf ASCE Eq: 7.4-1 Wind Design Criteria Wind Design Code ASCE 7-10 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 110 mph Fig. 26.5-1A Exposure Category C Section 26.7 Roof Style Gable Roof Fig. 30.4-2A/BIC-5A,/8 Mean Roof Height h 15 ft Section 26.2 Effective Wind Area 1 Module A 17.8 sf IBC 1509.7.1 Wind Pressure Calculation Coefficients Wind Pressure Exposure Kz 0.85 Table 30.3-1 Topographic Factor Kzt 1.00 Section 26.8 Wind Directionality Factor Kid 0.85 Section 26.6-1 Importance Factor I NA Velocity Pressure qh qh = 0.00256 (Kz) (Kzt) (Kd) (VA2) Equation 30.3-1 22.4 psf Ext. Pressure Coefficient (Up) GCp (Up) -0.88 Fig. 30.4-2A/B/C-5kB Ext. Pressure Coefficient Down GC Down 0.45 Fig. 30.4-2A/BIC-5A/B Design Wind Pressure P p = gh GC Equation 30.4-1 Wind Pressure Up p(up) -19.6 psf Wind Pressure Down down)___16.0 psf Allowable Standoff Spacings X -Direction Y -Direction Max Allowable Standoff Spacing Landscape 72" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Not -Staggered Max Standoff Tributary Area Trib 20 sf A. PV Assembly Dead Load W -PV 3 psf Net Wind Uplift at Standoff T -actual -196 lbs Uplift Capacity of Standoff T -allow 500 lbs ` Standoff Demand/Capacity DCR 39.2% Max Allowable Standoff Spacing Portrait 48" 66" Max Allowable Cantilever Portrait 20" NA Standoff Confi uration Portrait Not Staggered Max Standoff Tributary Area Trib 22 sf PV Assembly Dead Load W -PV 3 psf Net Wind Uplift at Standoff T -actual -219 lbs Uplift Capacity of Standoff T -allow 500 lbs Standoff Demand/Capacity DCR 43.9% RAO RESIDENCE 5.2 KW PV ARRAY PAGE NAME: UPLIFT CALCULATIONS Dana Irving SHEET: REV: DATE: PV 4 1/15/2015 CUPERTINO Li0ding Department 2015 10E COMPLIANCE SolarCity. 3055 Clearview Way San Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 (888) -SOL -CITY (765-2489) www.solarcitycom GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (E) GROUND ROD Panel Number: Inv 1: DC Ungrounded INV 1 — ( i) ABB # PVI-3.6—OUTD—S—US—Z—A LABEL: A — (20) REC# REC260PEZ CA # 888104 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number: 1006138563 FCI Inverter; Zigbee 360OW, 240V, 96% PV Module; 260W, 234.3W PTC, MC4, 40mm, Black Frame, ZEP Enabled C-10 INV 2 Underground Service Entrance Voc: 37.8 Vpmax: 30.7 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 125A MAIN SERVICE PANEL E 10OA/2P MAIN CIRCUIT BREAKER ADJUST MIN. ACTIVATION VOLTAGES! SolarCity (E) WIRING CUTLER—HAMMER Inverter 1 IND q A 1 10OA/2P Disconnect 5 ABB A DC- VStart = 120V LOADS PVI-3.6—OUTD—S—US—Z—A DC- MP1 1x9 J (E) B----------- Li 240V r — — — — — — — — — — — — — — — — — — — — _ �: L2 I DC, 20A/2P _ _ _ _ GND A ------------------------------------- N DC- 1 _ EGCI DC+ GEC ---Ti DC- 3 2 DC+ VStart = 120V DC- MP2: 1x11 I 8 I I GND -- EGC------------ ------------ ---�---- -- —EGC-----------------J I I (1 )Conduit Kit; 3/4' EMT N I I EGCIGEC — J Z Z c� TO 120/240V SINGLE PHASE UTILITY SERVICE I I I Voc* = MAX VOC AT MIN TEMP OTT (1) MURRAY MP2 020 PV ACKFEED BREAKER l Breaker; 20A�P-20A/2P-20A%1P, 2 Spaces, Quad R v (1) CUTLER—HAMMER DG221URB Disconnect; 30A, 24OVac, Non—Fusible, NEMA 3R AC (1 ) SolarCitY 4 STRING JUNCTION BOX 2x2 STRINGS, UNFUSED, GROUNDED DC —(1)CUTLER—HAMMER A DG030NB Ground/Neutral it; 30A, General Duty (DG) CUPERTINO d ,1 1301ding Department O 1 )AWG j110, THWN-2, Black o (1 )AWG #10, THWN-2, Red (i)AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC Imp 16 AAC (1)AWG /10, THAN -2, Black Voc* = 452.85VDC O (1 )AWG #10, THWN-2, Red Vmp = 337.7 VDC (1 AWG /10, THWN-2, Green. EGl Isc = 9.01 ADC Imp= 8.5 ADC (2 )AWGack A Voc* = 370.51 VDC Isc = 9.01 ADC O (1)AWG { - per 2Vj p *,{?6.3 VDC Imp= 8.5 ADC 70 )AWG8,, T}{WN-2,. Green . ,EGC/GEC.-(1 )Conduit. Kit.3/4'.EMT........ .. _ .. ..... (1 AWG /10, THWN-2, Black Voc* = 370.51 VDC ® (1 )AWG 110, THWN-2, Red Vmp = 276.3 VDC Isc = 9.01 ADC Imp= 8.5 ADC (2)AWG iiV'', I k _ Voc* = 452.85VDC Isc = 9.01 ADC O (1 )AWG 1 �5tfl� dl' t.(g0E=(MflARq,4RCP.5 ADC (1)AWG /1,0, THWN72,.Green.. EGC................................ ...... .... R&ie,wie;'' CONFIDENTIAL —THE INFORMATION HEREIN CONTAINED SHALL NOTCE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., JOB NUMBER: JB -9504301 00 PREMISE OWNER: RAO, KRISHNA DESCRIPTION: RAO RESIDENCE DESIGN: Dana Irving,So�a�Ci}" ����� ■ �'•,�• MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C P 10676 AMULET PL 5.2 KW PV ARRAY ►�, J 1 l y PART OTHERS OUTSIDE THE RECIPIENTS C U P E R TI N 0, CA 95014 MODULE 3055 geary ew Way San Mateo, CA 94402 IZ ORGANIZATION, EXCEPT IN CONNECT ON WITH THE SALE AND USE OF THE RESPECTIVE (20) REC # REC260PEZ PAGE NAME: SHEET: REV: DATE: INVERTER: ABB PVI-3.6-OUTD-S-US-Z-A SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. (408)_ 733-8870 THREE LINE DIAGRAM PV 5 1 15 / /2015 T:(650) 638-1028 F:(650) 638-1029 (888)—SOL—CITY (765-2489) www.solarciiy.com ii,,SolarCity ZepSolar Zep System for composition shingle roofs Q �0MPAT1e ti A�OWN'\O UL LISTED ON zepsolar.com Next -Level PV Mounting Technology Qn,nd Zep Inteiiock ;Key see arum) Levering root Zep Compatible PV Module i 2eD Groove - _ - Root Attachment ARMY Skirt:::.. , Description • PV mounting solution for composition shingle roofs • Works with all Zep Compatible Modules • Zep System UL 1703 Class A Fire Rating for Type 1 and Type 2 modules • Auto bonding UL -listed hardware creates structual and electrical bond Specifications • Designed for pitched roofs • Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467 • Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72" and cantilevers up to 24" Zep wire management products listed to UL 1565 for wire positioning devices • Attachment method UL listed to UL 2582 for Wind Driven Rain This document does not create any express warranty by Zap Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of Zep Solar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. i"SolarCity Z pSolar Components zepsolar.com Next -Level PV Mounting Technology iD O Comp Mount Part No. 850-1345 Listed to UL 2582, Mounting Block to UL 2703 i) Ground Zep Part No. 850-1172 Listed to UL 2703 and ETL listed to UL 467 Interlock Part No. 850-1388 Listed to UL 2703 k1k Array Skirt, Grip, End Ca Part Nos. 500-0113, 850-1421, 850-1460, 850-1467 Listed to UL 2703 'k UPER] ildin9 Dept r ,Wire Cllp:,g E �U� Part No. 850-1448 i Evl E t4jsr-4L(A5C ()0E OOMPL, Reviewed By This document does not create any express warranty by Zep Solar or about its products or services. Zap Solar's sole warranty is contained in the written product warranty for each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of Zep Solar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. 12 22 14 ZS for Comp Shingle Cutsheet Rev 02.pdf Page: 1 of 2 12 22 14 ZS for Comp Shingle Cutsheet Rev 02.pdf Page: 2 of 2 NO �,.. 7swsR•••••••••rrrsq� 1 U J time power tracking and improved — Single phase and split phase output number of rooftop solar panels energy harvesting. grid connection. enabling home -owners to get the most The flat efficiency curve ensures high This family of single-phase string The high-speed MPPT offers real- Highlights: inverters complements the typical time power tracking and improved — Single phase and split phase output number of rooftop solar panels energy harvesting. grid connection. enabling home -owners to get the most The flat efficiency curve ensures high — Wide input range for increased efficient energy harvesting for the size efficiency at all output levels allowing stringing flexibility. of the property. a consistent and stable performance — The high speed and precise MPPT across the entire input voltage and algorithm offers real time power This inverter offers a dual input output power range. tracking and improved energy section that processes two strings The transformerless operation gives the harvesting. with independent Multiple Power Point highest efficiency of up to 97.0%. — Outdoor NEMA 4X rated enclosure Tracking (MPPT). The wide input voltage range makes for unrestricted use under any This is especially useful for rooftop the inverter suitable to low power environmental conditions. installations with two different installations with reduced string size. — Integrated DC disconnect switch orientations from two sub -arrays This rugged outdoor inverter has been in compliance with international oriented in different directions. (For designed to be a completely sealed Standards (-S Version). example: East and West) unit able to withstand the harshest The dual input sections with environmental conditions. W independent MPPT enable a more w w w W W optimal energy harvesting condition. i W Power and productivity I, ,! ,! Rated grid d AC volta 208V for abetter world'" P%IP,P Additional highlights: ��•` " — RS -485 communication interface (for connection to laptop or data logger). — Integrated Arc Fault Detection and As Interruption (-A Version). CI CI W Ci G Technical data and types < 0.6w_ < 8w UPE 16 characters x 2 lines LCD displa ��.�.��' `TING VSN700 Data Lo., ger (opt.) .. -, ...... I(dl nq Department 13 F to +140°F with deratin above 122 -4&° to +176"F (-40°C to +80'_.. - li ry 4 0-10046.RH condensin < 50 db (A). r�..... m..................................................................................................... ............................................................... Type code PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US PVI-4.2-OUTD-US Mechanical specifications Nominal output power 3000W 360OW 3W0 380OW 420OW ......................................................................................................... Maximum output power wattage 3000 i..................f..... ; 3300 .3300 3600 ...............f....................................r.... 4000 . 4000 3300. ..... 4200 4200 .. 4200 € 4600 : 4600 WW ' W W w w w W W W i W w Rated grid d AC volta 208V 240V 277V 208V 240V 277V 208V 240V 277V 208V i 240V 277V Input side (DC) Number of independent MPPT channels 2 _. 2 2 2 Maximum usable ower for each channel power ....... 2000W ...... 3000W 3000W 3000W ... Absolutemaximum volta9e..(V7. i..................... _....... .. ......................_....:... ...... ............. ............................ Start-up voltage_(Vstart).................................................... ... ......................................................................................................... ........................................... ........................................ ........_600V............................................ ........................................................ 200V (ad1.:.120-350V)...................................,................................... - Full power MPPT,voltage_ran�s 160-530V 120-530V 140-530V 140-530V ............. Operating MPPT voltage range ............ 0.7 x Vstart - 580V (>=90V) .. .. ........ Maximum current (Idcmax) for both lvlPpT In 20A 32A 32A 32A parallel Maximum usable current per channel P 10A 16A 16A 16A Maximum short circuit current limit .... ..................................... channel 12.5A 20.OA € 20.OA 20.OA Number of wire landing terminals per channel ..... 2.Pa(................................................................................................................. Array wiring termination Terminal block, pressure clamp, AWG 10-AWG4 Output side (AC) Grid connection type 10/ Split -10/ 10/ : �pllt- 10/ 10/ Split- 10/— to/ Spilt- 1�i� 2W 0/3W 2W 2W 0/3W . 2W 2W 0/3W 2W 2W :. i 2W. .................................. Adjustable voltage range (Vmin-Vmax) M 183 _ way 211 : 9Aev 244- znnv 183 _ 9!)au 4- 211- 24 183 0Aev 1 gnnv oonv 1- 24 214 �Aev Inn% 183- oonv 11 i 2- ganv 244- gnnv Maximum current (I—) ! .........................................._...._...............................................................�!ran.....i....t4w.¢....i..._Aws........tw....l..._�iws...s....%'!r�.........!�roas.........%�Hus........C�.._......6........ %�.........%�..... Power factor > 0.995 ............F6............................................................................................€................................................................................................................................................................................................................................................ Total harmonic distortion at rated power ....<.2% ......... .........:...... ......... ......... ....,............ ....._...................... ...... .... ......... ............. Grid wiring termination type Terminal block, Pressure clamp, AWG10-AWG4 Input protection devices Reverse polarity protection Yes ........................................ .................................... Over -voltage protection type Var stor, 2 for each channel ....... ................... . .... ........ PV array qround fault detection Pre start-uo Riso and Dynamic GFDI (reauires floatina arrays) ... .. ........................... ..... ...................... ... Over -voltage protection type Varistor, 2 (L, - La / L G) .... ............... .................. Maximum efficiency .. 1. Capability enabled at nominal AC voltage and with sufficient DC po 2 ABB Solar Inverters I Product flyer for PVI-3.0/3.6/3.8/4.2-TL-OUTD 96 < 0.6w_ < 8w UPE 16 characters x 2 lines LCD displa ��.�.��' `TING VSN700 Data Lo., ger (opt.) .. -, ...... I(dl nq Department 13 F to +140°F with deratin above 122 -4&° to +176"F (-40°C to +80'_.. - li ry 4 0-10046.RH condensin < 50 db (A). r�..... m..................................................................................................... ............................................................... ..................... ...........................:s5son(2000m)............. ....k- EV.#EWE&FOR...CCJDE COMPLIANCE Reviewed By Label Location: (C)(IC)(CB) Per Code: CRC R331.2 Label Location: (DC) (INV) Per Code: CEC 690.14.C.2 Label Location: (DC) (INV) Per Code: CEC 690.53 Label Location: (DC) (CB) Per Code: CEC 690.17 Label Location: (INV) Per Code: CEC 690.5(C) Label Location: (AC) (POI) Per Code: CEC 690.14.C.2 Label Location: (AC) (POI) Per Code: CEC 690.54 Label Location: (AC) Label Location: (DC) Per Code: CEC 690.17 Label Location: (POI) Per Code: CEC 705.12.D.7 Label Location: (POI) Per Code: CEC 690.54; CEC 690.17 Label Location: (D) (POI) Per Code: CEC 690.64.13.4 Label Location: (POI) Per Code: CEC 705.12.D.7 Label Location: (DC)(INV)(CB) Per Code: CEC 690.35(F) TO BE USED WHEN INVERTER IS UNGROUNDED NC uPEPTINq R _I 601ding Department JAN 21 2015 REVIEWED rORR CODE CC tAPL.IANC� (AC): AeB'IS�bn If y y •c+f' (C): Conduit (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit (INV): Inverter With Integrated DC Disconnect (LC): Load Center (M): Utility Meter (POI): Point of Interconnection CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR `%%of 3055 Cleaview way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED �- San Mateo, CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, SC - CA Label Set T:(650)638-1028 F:(650)638-1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE „ SolarCity-l(888)-SOL-CFY(765-2489) www.solarcity.com 1 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. HIGH PERFORMANCE SOLAR PANELS REC PEAK ENERGY REC Peak Energy Z -Link Series solar panels are the perfect choice for building solar systems that combine long lasting product quality with reliable power output. REC combines high quality design and manufacturing standards to produce high- performance solar panels with uncompromising quality. REE PEAK ENERGY ZLINK 5FRI�� 65.55 to. I 1.38 EFFICIENCY YEAR PRODUCT WARRANTY YEAR LINEAR POWER OUTPUT WARRANTY F ZT ZFF U5 IMPORT DUTY FREE TEMPERATURE RATINGS Nominal Operating Cell Temperature(NocT) 45.7'C (±2'C) Temperature Coefficient of PMP, -0.40%/'C Temperature Coefficient of V, -0.27%/'C Temperature Coefficient of Is, 0.024%/'C All measurements in Inches 47.24 REC26oP13 160 GENERALDATA Cell Type: 60RECPEmulti- crystalline 0.47 U ./-5 r Nominal PowerVoltage-VM„(V) 30.7 Glass: 0.125 in solar glass with anti -reflection EFFICIENCY YEAR PRODUCT WARRANTY YEAR LINEAR POWER OUTPUT WARRANTY F ZT ZFF U5 IMPORT DUTY FREE TEMPERATURE RATINGS Nominal Operating Cell Temperature(NocT) 45.7'C (±2'C) Temperature Coefficient of PMP, -0.40%/'C Temperature Coefficient of V, -0.27%/'C Temperature Coefficient of Is, 0.024%/'C All measurements in Inches ELECTRICAL DATA @ STC Nominal Power -PN„ (Wp) REC26oP13 160 GENERALDATA Cell Type: 60RECPEmulti- crystalline Watt Class Sorting-(Wp) ./-5 3 strings of 20 cel Is with bypass diodes Nominal PowerVoltage-VM„(V) 30.7 Glass: 0.125 in solar glass with anti -reflection surface treatment Nominal Power Current -IM,p(A) 8.50 Back Sheet: Double layer highly resistant polyester Open Circuit Voltage-V«(V) 37.8 Frame: Anodize daIuminum(black) Short Circuit Current- I,c (A) 9.01 Zep Groove compatible Panel Efficiency(%) 15.8 Junction Box: IP67rated 0.156 in (12 AWG) solar cable, 2 x 4724 in The electrical characteristics are within 10% of the indicated Values at standardtest conditionsSTC(airmass AM l.S, irradiance values of lr,V, andP o at standard Test conditions (STC). 1000 W�m', cell temperature 77"F(25'C)). *onnectors: H4Amphenol At low Irradiance of 200 W/m' (AM 1.5 & cell temperature 77'F (25'C)) at least 97% of the STC panel efficiency will be achieved. Origin: Made In Singapore ELECTRIC ALDATA@NOCT Nominal Power -P., Wp) t• 197 iftperationalTemperature: -40...+185°F(-40...+85°C) Nominal PowerVoltage-V.(V) 29.0Bximum System Voltage: 1000VUL Nominal PowerCurrent- I_ (A) 6.81 esignLoad: 501bs/ft2(2400Pa) tong side Open Circuit Voltage - Vo, (V) 35.7 30lbs/ft2 (1436 Pa) short side Short CircuitCurrent- Is, (A) 7.24 ax Series Fuse Rating: 15A -ax Nominal operating cell temperature NOCT(800 W/m',AM LS, windspeedI m/s, ambient temperature 68'F(20'C). Reverse Current: 15A CERTIFICATION r. . nj Dimensions: 65.55 x 39.02 x l.57!n (1665 x 99l x 40 mm) 10 year product warranty. c �L us 25 year l!nearpower output warranty Area: 1775ft2(1.65m2) LISTED (max. degression in performance of 0.7% p.a.). o Weight: 431bs(19.5 kg) UL 1703, Fire rating: Type 1, Class C o Note! All given specifications are subject tochange without notice at any time. REC is a leading global provider of solar energy solutions. With more than 15 years of experience, we offer sustainable, h`4$h pert rmSn� NO products, services and investments for the solar industry. Together with our partners, we create value by providing solut %i6 F2 u ( — meet the world's growing energy needs. REC is headquartered in Norway and listed on the Oslo Stock Exchange(ticker-RE ).0 ! Depa r employees worldwide generated revenues of USD 647 million in 2013. wwwyyrectgroup.com REVIEWED TUR C:UDE i:UrJ1 f:evlewed By � „