15040059 (2)TESTING ENGINEERS, INC.
2811 Teagarden St. 510-835-3142 510-834-3777 fax
San Leandro, CA 94577 800-660-3142
San Leandro • San Jose • Martinez
INSPECTION REPORT Week Ending: 10/23/15
PROJECT # 62045
PROJECT:
6 hifinite Loop IL06.4E
Cupertino, CA
Permit # 15040059
DATE 10/21/15
HOURS 4
INSPECTOR J. Souza
Reported to Alan of Novo Construction at the jobsite as requested.
TYPE OF INSPECTION:
Proof Load Testing
PLACE OF INSPECTION:
Jobsite
Applied a torque load of 40 foot lbs. to 1/2' diameter Hilti KB -TZ expansion anchors located in the existing concrete floor at
the 41h floor anchoring Thermal Chamber (8) and base cabinet (4). Twelve (12) anchors of a total of 12 installed were tested
representing 100% without visually apparent distress or failure.
The preceding work was, to the best of my knowledge, in compliance with approved job plans and specifications, including
revisions by engineer, and Drawing S3, dated 10/12/15; and proof loading values and rate of testing were supplied by
manufacturer's specifications.
1cc: Apple Computer Inc. / R. Anchartechahar
City of Cupertino / Bldg. Inspection Dept.
by:.
Inspection Division Manager
The results presented in this report relate only to the item(s) tested/ inspected and
may be reproduced only in its entirety unless written permission from TEI is obtained.
Page 1 of 1
f.
TESTING ENGINEERS, INC.
October 21, 2015
City of Cupertino
Building Inspection Department
10300 Torre Avenue
Cupertino, California 95014
Subject: FINAL REPORT
Project: 6 Infinite Loop I1,06.4E
Cupertino. California
Gentlemen:
Quality Assurance Services
Materials Consulting
Since 1954
TEI Project No. 62045
Permit No. 15040059
In accordance with Section 1704 of the California Building Code, we have provided special inspection of:
Proof loading of expansion anchors in existing concrete.
These inspections were performed by personnel under the general supervision of a Registered Civil Engineer in
the State of California. Based upon our inspections performed and our substantiating reports, the inspected work
requiring special inspection was, to the best of our knowledge, in conformance with the approved plans and
specifications, the applicable workmanship provisions of this Code, and any changes by the Engineer of Record.
Details of our work on this project are
the progress of construction.
TESTING ENGINEERS,
. Min
Terry L. Egland, P.E.
CE # 34132, Exp. 6/30/17
in our testing and inspection reports that were submitted during
cc: Apple Computer Inc. / R. Anchartechahar
Corporate Office - 2811 Teagarden Street - San Leandro, California 94577 - (510) 835-3142 - FAX (510) 834-3777
www.Testing-Engineers.com
P_ .
AdIbil
TESTING ENGINEERS, INC.
2811 Teagarden St. 510-835-3142 510-834-3777 fax
San Leandro, CA 94577 800-660-3142
San Leandro San Jose • Martinez
INSPECTION REPORT Week Ending: 10/23/15
PROJECT # 62045
PROJECT:
6 Infinite Loop IL06.4E
Cupertino, CA
DATE
Permit # 15040059
10/21/15
INSPECTOR J. Souza
Reported to Alan of Novo Construction at the jobsite as requested.
TYPE OF INSPECTION:
Proof Load Testing
PLACE OF INSPECTION:
Jobsite
Applied a torque load of 40 foot lbs. to 1/i' diameter Hilti KB -TZ expansion anchors located in the existing concrete floor at
the 4w floor anchoring Thermal Chamber (8) and base cabinet (4). Twelve (12) anchors of a total of 12 installed were tested
representing 100% without visually apparent distress or failure.
The preceding work was, to the best of my knowledge, in compliance with approved job plans and specifications, including
revisions by engineer, and Drawing S3, dated 10/12/15; and proof loading values and rate of testing were supplied by
manufacturers specifications.
by:.
1cc: Apple Computer Inc. / R. Anchartechahar
City of Cupertino / Bldg. Inspection Dept.
Inspection Division Manager
The results presented in this report relate only to the item(s) tested/inspected and
may be reproduced only in its entirety unless written permission from TO is obtained.
Page 1 of 1