Loading...
15090136 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 10846 LINDA VISTA DR CONTRACTOR:WILLOW GLEN PERMIT NO: 15090136 ELECTRIC INC OWNER'S NAME: SACHS AVI I AND GILLER-SACHS ANAT T 1085 WARREN AVE DATE ISSUED:09/21/2015 O—WNNER'S PHONE: 4082037445 SAN JOSE,CA 95125 PHONE NO:(408)289-9725 CL/ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL ❑ COMMERCIAL ❑ INSTALL(N)240V TRANSFER SWITCH NEXT TO(E)SUB License Class —1 Li,.# 5 t ( y PANEL IN GARAGE TO CHARGE EITHER(E)A/C UNIT OR LL (N)TESLA EV CHARGER(30AMP) Contractor W' � � 4(cckj_ Date -Z r I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: Sq.Ft Floor Area: Vahiati"n:S23()() r. I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. %PN Number:35614049.00 (rccupanc) I N pe: I have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. PERMIT EXPIRES IF WORK IS NOT STARTED APPLICANT CERTIFICATION WITHIN 180 DAYS OF PERMIT ISSUANCE OR I certify that 1 have read this application and state that the above information is correct.1 agree to comply with all city and county ordinances and state laws relating 180 DAYS FRO NSPECTION. to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save indemnify and keep harmless the City of Cupertino against liabilities,judgments, Date: costs,and expenses which may accrue against said City in consequence of the "ranting of this permit. Additiona y,the applicant understands and will comply with all non-point source regulati s r the Cupertino Municipal Code,Section 9.18. RE-ROOFS: Signature Date --2 �� All roofs shall be inspected prior to any roofing material being installed.If a roof is installed without first obtaining an inspection,I agree to remove all new materials for inspection. OWNER-BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of i h v following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER i,as owner of the property,or my employees with wages as their sole compensation,will do the work,and the structure is not intended or offered for HAZARDOUS MATERIALS DISCLOSURE sale(Sec.7044,Business&Professions Code) 2. 1,as owner of the property,am exclusively contracting with licensed contractors to I have read the hazardous materials requirements under Chapter 6.95 of the construct the project(Sec.7044,Business&Professions Code). California Health&Safety Code,Sections 25505,255339 and 25534. 1 will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the Health& 1 hereby affirm under penalty of perjury one of the following three declarations: Safety Code,Section 25532(a)should 1 store or handle hazardous material. t. I have and will maintain a Certificate of Consent to self-insure for Worker's Additionally,should I use equipment or devices which emit hazardous air Compensation,as provided for by Section 3700 of the Labor Code,for the contaminants as defined by the Bay Area Air Quality Management District I N ill maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the performance of the work for which this permit is issued. Health&Safety Code,Sections 25505,25533,and 25534. 2. 1 have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this Owner or authorized agent: permit is issued. Date: 3. 1 certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's MNSTRUCTION LENDING AGENCY Compensation laws of California. If,after making this certificate of exemption,1 I hereby affirm that there is a construction lending agency for the performance of work's become subject to the Worker's Compensation provisions of the Labor Code,I for which this permit is issued(Sec.3097,Civ C.) must forthwith comply with such provisions or this permit shall be deemed Lender's Name revoked. Lender's Address APPLICANT CERTIFICATION I certify that 1 have read this application and state that the above information is ARCHITECT'S DECLARATION correct.I agree to comply with all city and county ordinances and state laws relating I understand my plans shall be used as public records. to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save Licensed Professional indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section 9.18. tii n,nurr Date _r • --VV 2 6 • r �v ■ @ r@•sw@■ • rte■ ■ r —_ ■ ■_-- COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION 10300 TORRE AVENUE•CUPERTINO, CA 95014-3255 C U P E RT I N O (408) 777-3228• FAX(408) 777-3333•building cDcupertino.org PROJECT ADDRESS I l l 1�6 L-104 V(Sk Dr.. \I'\.. 3 / Y — D Y OWNER NAME 4u'' C QC S PHONE Lkc)16/ 1 Z t'_,'LM` E-MAIL STREET ADDRESS CITY, STATE,ZIP C�vI,/ FAX CONTACT NAME l Matt LonLdre 7 PHONE / ( E-MAIL (408) 705-3663 Matt willowglenelectric.corn STREET ADDRESS PO Box 8430 CITY,STATE, ZIP San Jose CA 95155 FAX ❑OWNER ❑ OWNER-BUILDER ❑ OWNER AGENT CONTRACTOR ❑CONTRACTOR AGENT ❑ ARCHITECT ❑ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME Mark Londre LICENSE NUMBER 591918 LICENSE TYPE C.10 BUS.LIC h 155897 COMPANY NAME Willow Glen Electric, Inc. E-MAIL info(9 willowglenelectric.corn FAX STREET ADDRESS PO Box 8430 CITY,STATE,ZIP San Jose CA 95155 PHONE (408)289-97'25 ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS.LIC a COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE USE OF SFD or Duplex ❑ Multi-Family PROJECT IN WILDLAND PROJECT IN STRUCTURE: ❑ Commercial URBAN INTERFACE AREA ❑ Yes ❑ NO FLOOD ZONE ❑ Yes ❑ NO ❑SOLAR PANELS 0 ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PANEL S: NUMBER OF PANELS/UNITS: KILOWATTS(09 N [_Y): Z i O J TOTAL VALUATION:�I y�0 DESCRIPTION OF WORK J�j71 Ong 4 V �Vl 4�j 5(N"' (� n+ �/� PX 1 ST I r IWA S'6 G W I N _ii)A Ac CA114 > �v� E V cC�Gc J-,n s�� l vie,,,, ���✓ �d,� t�- 4-CC,V1 s SLt,r'fClk J411EIVED BY: By my signature below,1 certify to each of the following: I am the property owner or authorized agent to act on o r s behalf. I have read this application and the information 1 have provided is correct. I have read the Description of Work and verify it is accura e. I agree to comply with all applicable local ordinances and state laws relating to bmithg construction. 1 authqnize representatives of Cupertino to enter the above-identified property for inspection purposes. TTr Signature of Applicant/Agent: Date: I It` 5 SUPPLEMENTAL INFORMATION REQUIRED OI ITc L I SE Ov,Y }W ❑ ON ER-THE-COI LATER F ❑ EXPRESS U ❑ STANDARD u Z ❑ LARGE 3 ❑ MAJOR CITY OF CUPERTINO FEE ESTIMATOR - BUILDING DIVISION ADDRESS: 10846 LINDA VISTA DR DATE: 09/21/2015 REVIEWED BY: MELISSA APN: 356 14 049 BP#: 'VALUATION: 1$2,390 PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration/ Repair _71 PRIMARY SFD or Duplex PENTAMATION SOLAR-RES USE: PERMIT TYPE. WORK INSTALL N 240V TRANSFER SWITCH NEXT TOE SUB PANEL IN GARAGE TO CHARGE SCOPE EITHER (E)A/C UNIT OR (N) TESLA EV CHARGER (30AMP) ;tfeeh. Plan Check l f, ElUdwr t/('ch. hup NOTE: This estimate does not include fees due to other Departments(i.e. Planning, Public Works, Fire,Sanitary Sewer District,School District,etc: . Thesefees are based on the preliminat3 information available and are only an estimate. Contact the De t or addn'l info, FEE ITEMS (l ee Resolution 11-053 hj) % l l31 FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 F17 # Alternative Energy System Suppl. PC Fee: Q Reg. O OT 0.0 Lhrs $0.00 $109.00 ICHRGSTA EV Charging Station PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Fee1q Reg. Q OT 0 0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 onWructiotr Tax: F•' O Work Without Permit? O Yes (F) No $0.00 0 Advanced Planning Fee: $0.00 Select a Non-Residential O l rai-cl Doc,.unccnhation Building or Structure O Strong Motion Fee: IBSEISAIICR $0.50 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $1.00 SUBTOTALS: $1.50 $109.00 TOTAL FEE: $110.50 Revised' 07/02/2015 AVI Sa�� S ���I� d SOV ( t-c,y� S Sw+'►�-, 108LI6 L�hdu M+c, Dr. �elCf- f-v + eniS�!5 (OOA 5Lb �Gt�1 iv f-Ine �64'0'4�z {-P s�P�ly power 4-Q e r'filne.r *Jtk e xi 5H uy �x7A h< 0�- f ntw ;OA E V c kGr5cr Q1V TO Sfu(( ovtjZ KU,/ 701� 9 a NE .M A (v-30 Ce Fo E tl I l�1,s GV1Ufyhr W tY� $1' ,O4 Y DEVELOPMENT DEPARTMENT BUILDING DIVISION - CUPERTINO Pui 9�Rrl�a APPROVED CJ ED SEP 1 eoartMen This set of plans and specifications MUST be kept at the 1015 a job site during construction. It is unlawful to make any REVIEW F R CODE changes or alterations on same,he BUIi�°9 Orae Review o COMIp� therefrom,without approval from t edgy LANCE The Stamping of this plan and specifirat ons SHALL NOT violation be held to permit or to be an apP rn("jv,- aw of any provisions of any Ci BY DATE PGy�' f 3 3� w� 4-*10 TON NEanA 10-3v J GrGJrQ I00A tMG1YN GT�� doa r PLAT PLANS CHECKED BY OFFICE C DATE PLANNING DEPT CUPERTINO Residential Electrical Load Calculation -TRANSFER SWITCH: EV ON, AC OFF Site Location: Prepared by I L L O W Avi Sachs Willow Glen Electric,Inc. �E N 10846 Linda Vista Drive PO Box 8430 L E CYNIC Cupertino,CA 95014 San Jose,CA 95155 // (408)203-7445 (408)289-9725-office General Lighting and Receptacle Loads 1220.121 3 watts per ft' x 1,888 = 5,664 Small-Appliance Branch Circuits 1220.52(A),210.1(0)(1)] 1,500watts x 2 = 3,000 Laundry Branch Circuit(s)(220.52(8),[210.11(C)(2)] 1,500watts x 1 = 1,500 10,164 Fastened-In-Place Appliances Kitchen Bath(s) Outisde Miscellaneous [220.53] Refrigerator(s) = 420 Instant Hot 1120(s) = Exhaust Fan(s) = Hot Tub = Dishwasher(s)= 1,188 Hood Exhaust(s) = 240 Jacuzzi Tub(s) = Pool Equipment = Garbage Disposal(s) = 972 Gas Range(s)= Radiant Heating = H2O Pump = Microwave(s) = 1,580 Gas Oven(s) = = H2O Pump = Trash Compactor= Wine Fridge(s)= = BBQ Area = _ = Vacuum = Total Fastened-in-place Appliance Load 4,400 Clothes Dryer(s)[220.54] 80% x 240 x Derating Volts Amps 5,000 OR Name Plate Rating of Clothes Dryer = 5,000 Ranges,Ovens,Cooktops,and Other Household Cooking Appliances 1220.551 80% x 240 x 40 = 7,680 Derating Volts Amps AND/OR Name Plate Rating of Cooking Appliances = Heating or Air-Conditioning System(Compare the .0 heat and A/C,and omit the smaller.)1220.601 Air Handler/Furnace M 115 x 6.0 = Volts Amps ;L; mC Air Conditioning Unit 690 C 55% x 240 x = < m ._..... Derating Volts Amps CD CD C! AND/OR (C TI Name Plate Rating of Air Handler&AC Units = n C' m Total Volt-Ampere Demand Load[220.83] 0 N Air-conditioning Equipment 690 x 100% = C C. 0 Greater of 690 q Electric Space Heating - x 100% _ M tV CT First 8kVA of all other loads 8,000 x 100% = 8,000 �} O V r Remainder of all other loads 19,244 x 40% = 7,698 C L� Q I x r�E1 l Total 16,388 �Z r 'D Current Minimum Amperes Current Minimum D I Z 16,388+ 240 = 68.3 100 Amps 7 O 17 Size Service or � (voltage) (minimum amperes) Feeder[240.6(A)) currently Electric Vehicle 1625.141 125% x 240 x 24 Continuous Load Volts Amps 7,200 Minimum Amperes with Added Load Minimum Size Divide the total 23,588 a 240 = 98.3 20 Service or Feeder 100 Amps volt-amperes by (voltage) (minimum amperes) w/Added Load with added load the voltage. 240 6(A)1 NOTES All References are to 2014 National Electrical Code. Residential Electrical Load Calculation -TRANSFER SWITCH: EV OFF, AC ON Site Location: Prepared by Avi Sachs Willow Glen Electric,Inc. ILLOWL E N 10846 Linda Vista Drive PO Box 8430 L.1 E C T 111 C Cupertino,CA 95014 San Jose,CA 95155 // (408)203-7445 (408)289-9725-office General Lighting and Receptacle Loads(220.12) 3 watts per ftz x 1,888 = 5,664 Small-Appliance Branch Circuits(220.52(A),230.1(C)(1)] 1,500 watts x 2 = 3,000 Laundry Branch Circuit(s)(220.52(B),[210.11(0)(2)] 1,500 watts x 1 = 1,500 10,164 Fastened-In-Place Appliances Kitchen Baths) Outisde Miscellaneous 1220.53] Refrigerator(s) = 420 Instant Hot H20(s) = Exhaust Fan(s) = Hot Tub = Dishwasher(s)= 1,188 Hood Exhaust(s) = 240 Jacuzzi Tub(s) = Pool Equipment = Garbage Disposal(s) = 972 Gas Range(s)= Radiant Heating = H2O Pump Microwave(s) = 1,580 Gas Oven(s) = = H2O Pump = Trash Compactor= Wine Fridge(s)= = BBQ Area = Vacuum = Total Fastened-In-place Appliance Load 4,400 Clothes Dryer(s)1220.541 80% x 240 x Derating Volts Amps 5,000 OR Name Plate Rating of Clothes Dryer = 5,000 Ranges,Ovens,Cooktops,and Other Household Cooking Appliances 1220.551 80% x 240 x 40 = 7.680 Derating Volts Amps AND/OR Name Plate Rating of Cooking Appliances Heating or Air-Conditioning System(Compare the /F dlerurnace heat and A/C,and omit the smaller.)Izzar>ol Air Han115 x 6.0 = Volts Amps Air Conditioning Unit 4,650 55% x 240 x 30 = Derating Volts Amps m AND/CR _< Name Plate Rating of Air Handler&AC Units M Total Volt-Ampere Demand Load(220.83] iD -" Air-conditioning Equipment 4,650 x 100% = i Greater of: 0) -0650 Electric Space Heating - x 100% = Q O (n First 8kVA of all other loads 8,000 x 100% = CC' X000 mom Remainder of all other loads 19,244 x 40% = 698 Total 56,348 Current Minimum Amperes t� C- 20,348 + 240 - 84.8 Current Minimum Q_A 5 r 17 Size Service or .C) 290 (voltage) (minimum amperes) Feeder[240.6(A)] \ gently T Electric Vehicle[625.141 D Z 125% x 240 x = u Continuous Load Volts Arps O Minimum Amperes with Added Load Minimum Size Divide the total 20,348+ 240 = 84.8 20 Service or Feeder 100 Amps volt-amperes by (voltage) (minimum amperes) w/Added Load with added load the voltage. (240.6(A)� NOTES All References are to 2014 National Electrical Code. Need help finding a qualified electrician,or have questions about home charging installation? Contact Tesla at:C inglnstallationgteslamotors.com or 1-877-798-3752 91j/ / Np S a Qen FP INSTALLING YOUR 240 VOLT OUTLET FWEUFO 2015 nt Every Model S includes the Mobile Connector,which is a 20-foot long cable with a set�G�/�W���CUFF c of adapters for standard electrical outlets.The NEMA 14-50 adapter ensures the best y charging experience with the Mobile Connector Tesla recommends installing a 240 Volt outlet with a NEMA 14-50 receptacle where you plan to park your vehicle.This is a common outlet,often used for home appliances,and the electrician you hire for the installation will provide all necessary materials. You can charge your Model S from this outlet at a rate of 29 miles per hour. Below you will find all relevant information required for an electrician to complete the installation. Note:municipal building departments frequently require a permit and inspection for any electrical modifications in your home.Any licensed electrician will be able to take care of this paperwork and provide a copy for your records. w DETAILS W a G Voltage: Single phase,208-250 Volt AC supply,60 Hertz 0 N Current:50 Amp circuit breaker/40 Amp continuous current ry Wiring Recommendation:6 American Wire Gauge,copper conductors only a 250V o �___, Ground Fault Circuit Interrupter:Not required 0 0 Service Disconnect: Not required Z Receptacle Recommendation:High quality, industrial grade receptacle Location: Install near vehicle charge port,maximum 15 feet away. Minimum T 18 inches above ground. a a Electric Code Compliance:Installing electrician will source permit and f Z inspection as required by local municipal building department RECOMMENDED OUTLET LOCATIONS FOR YOUR RECORDS ONE OR TWO VEHICLE GARAGE ELECTRICAL COMPANY PHONE NUMBER I EMAIL ADDRESS .................. ,# J* CHARGE PORT PERMIT NUMBER OUTLETS O ...... .. INSTALLATION DATE T S S L n 3500 Deer Creek,Palo Alto,CA 94304 1 Nov.2014 1 Version 1.0 F SERIES DOUBLE THROW SAFETY SWITCHES (30A-200A) These exclusive F Series Double Throw Switches are rated heavy- duty making them ideal for use in the most rugged conditions, including residential, light commercial and industrial manual transfer applications. Most applications can bemet ith a full range of fusible and not p.� fusible switches to select fro many field installable accessories, such as electri 'ks and solid neutrals, provide even greater flexibility. And Mclustry's excAsive F Series design you'll enjoy all the benefits'of the most re iab� innovative line of safety switches in the industry �`J'/o'', `, ,, oea NO wEC;ti SFp? 7nfc went Reliable Performance an4,Exte6&0 Equipment Life ■ Blade and jaw switch const u` ,s the i� s preferred approach for a tight, clean closure bn th 4PIA e tin- plated copper current-carrying componentrrediice cor�on and oxidation to prolong the switch life. ■ Designed to the tough NEMA standards set for heavy-duty • switches to create a durable switch that outlasts and outperforms I all others. ■ Easy-to-throw, tough-to-break operating mechanism is guaranteed to meet the number of no-load operations required by UL and NEMA standards. 60A Fusible Double Throw Switch ■ Outlasts and outperforms all others — exclusive modular construction on all the interior components allows easy maintenance and replacement of parts, reducing downtime and simplifying maintenance. In any value comparison Flexibility to Meet More Applications SQUARE D Safety Switches ■ Fusible and not fusible switches available. are the winner! ■ Enhanced horsepower and SCCR ratings. • Time-saving features for fast and ■ Easy field re-configuration allows one switch to meet two easy installation applications: source/single load (motor switching) or single • Advanced features and modular source dual load. design provide cost saving ■ Field installable accessories provide easy-to-install kits that let maintenance you quickly add a solid neutral or electrical interlock at the job. • A full range of operation Maximum Convenience for Installation and Use features for maximum safety ■ Dual cover interlock prevents the cover from being opened when and convenience the switch is ON or from turning the switch ON when the cover is open. ■ Embossed ON/OFF markings will not fade like printed or painted markings. ■ Ample wire bending space allows cables to enter and exit the same endwall for wiring convenience. ■ Side-opening door swings 1800 to remain out of the way during installation and maintenance. Sc�rx ntd•��.r,,frrx ® SQUARE D Schneider Electric F Series Double Throw Switches Safety Switches Ordering Information Kit Ordering Information NEMA NEMA Horsepower Ratings Normally open/ FCatalog Type 1 Type 3R 240 Vac 250 Vdc Switch Rating closed contact(s) Number Catalog Catalog Std. Max. Std. Electrical Interlock Kits Number Number 1ph 3ph 1ph 3ph 30A-200ATypeDT,DTU 1 1 EIK1■ DT223 DT223RB 7.5 15& 15 30& 20 Series F 22 EIK20 DT321 DT321 RB 1.5* 3& 3* 7.5& 5* DT24 DT224RB 15 25& - 60& 40 Class R Fuse Kits(order two kits per 3-pole switch) DT322 DT322RB 3* 7.5& 10* 15& 10* 240V 30A NA RFK03 DT323 DT323RB 7.5* 15& 15* 30& 20* 600V 30A or NA RFK06 DT324 DT324RB 15A 25& - 60& 40A 240V 60A 600V 60A NA RFK06H NEMA NEMA Horsepower Ratings 240V 100A or NA RFK10 Type 1 Type 3R 240 Vac 250 Vdc 600V 100A Catalog Catalog Std. Max. Std. 200A NA HRK1020 Number Number 1ph 3ph 1 h F3ph DTU222 - - - 10 - 10 Neutral Kit* DTU223 DTU223RB - - 15 - 20 (3-pole Equipment DTU224 DTU224RB 15 25& - 60& 40 Switch Rating switch only) Ground Kit DTU321 - - 3& 5* 10& 5* 30A-100A Type DT, DTU SN0310 Included DTU322 - - - 10* 15& 10* Series F DTU323 DTU323RB - - 15* 30& 20* 200A (2)SN20A plus Included DTU324 DTU324R6 15A 25& - 60& 40A (1)SN20N1 neutral NEMA NEMA Horsepower Ratings jumper kit Type 1 Type 3R 480 Vac 1 600 Vac 250 Vdc 600 Vdc Catalog Catalog Std. Max. Std. Max. * When all copper current carrying parts are required, Number Number 3 h 3 h 3 h 3 h use SN0310C for 30A-100A, CSN20A for 200A. DT361 DT361 Number 5& 15& 7.5 20 5' 15' ■Switches contain two separate switching mechanisms. DT36DT36RB 15& 30& 15 50 - 30* Each mechanism will accept an electrical interlock. DT363 DT363RB 25& 60& 30 75 - 50* DT364 DT364RB 1 50& 1 125& 60 150 40A I 50A* NEMA NEMA NEMA NEMA Horsepower Ratings Type 1 Type 3R Type 4.4X,5 Type 12 240 Vac 480 Vac 600 Vac 250 Vdc 600 Vdc Catalog Catalog Catalog Catalog Max. Max. Max. Max. Max. Number Number Number Number 1 ph 3 ph 1 ph 3 ph 1 ph 3 ph DTU361 DTU361 RB - - 5* 10& 7.5* 20& 10* 30 5' 15* DTU362 DTU362RB DTU362DS DTU362AWK 10* 20&@ 25* 50&♦ 30* 60 10* 30* DTU363 DTU363RB DTU363DS DTU363AWK 20* 40& 40* 75&"" 40* 75 20* 50* DTU364 DTU364RB DTU364DS DTU364AWK - 60A 50A 125& 50A 150 40* 50* - DTU662AWK - 20 - 50 - 60 10 30 - DTU663AWK - 40 - 75 - 75 20 50 - DTU664AWK - 60 - 125 - 150 - - NEMA NEMA NEMA Horsepower Ratings Type 1 Type 4.4X,5 Type 12 240 Vac 480 Vac 600 Vac 250 Vdc 600 Vdc Catalog Catalog Catalog Max. Max. Max. Max. Max. Number Number Number 2 h 3ph 2 h 3ph _22h 3 h DTU462 DTU462DS DTU462AWK 20 20 40 50 50 50 10 30 DTU463 DTU463DS DTU463AWK 30 40 50 75 50 75 20 30 DTU464 I DTU464DS IDTU464AWK 50 60 1 50 125 1 50 150 1 40 150 & If comer grd.Delta,install neutral and use outer @ Maximum hp is 15 for corner grounded delta systems. switching poles for ungrounded conductors. ♦ Maximum hp is 30 for corner grounded delta systems. < Maximum rating. "^ Maximum hp is 50 for comer grounded delta systems. * Use outer switching poles. * Standard rating. A Use any two switching poles. 02001 Schneider Electric All Rights Reserved D SQUARE D Document Number 3100H00101 R8/01 Schneider Electric SMOKE / CARBON MONOXIDE ALARMS OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION CUPERTINO 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408)777-3228• FAX(408)777-3333• building(aD-cupertino.orq / v1do, Permit No.Address Wy 6 t I Vnjclb C #of Alarms Smoke: < Carbon Monoxide: / PERMIT CANNOT BE F INALED AND COMPLETED UNTIL THIS CERTIFICATE HAS BEEN SIGNED AND RETURNED TO TILE BUILDING DIVISION PURPOSE This affidavit is a self-certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R314, 2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single-family and multi-family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds $1000.00,CRC Section R314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations: AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of the X X bedroom(s) On every level of a dwelling unit including basements X X Within each sleeping room X Carbon Monoxide alarms are not required in dwellings which do not contain fuel-burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. Power Supply:In dwelling units with no commercial power supply, alarm(s) may be solely battery operated. In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic,basement or crawl space. Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2.An electrical permit is required for alarms which must be connected to the building wiring. As owner of the above-referenced property, I hereby certify that the alarm(s) referenced above has/have been installed in accordance with the manufacturer's instructions and in compliance with the California Building and California Residential Codes.The alarms have been tested and are operational, as of the date signed below. I have read and agree to comply with the terms and conditions of this statement Owner(or Owner SgeName: '/} a Signature................. . .. ..... ... ...............................................................................Date: A .1.. .. ontractor Name: Sinature...................................................................Lic.#......................................Date: ................... Smoke and CO form.doc remised 03/18/14 WATER-CONSERVING PLUMBING FIXTURES OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION C O P E RT I N O 10300 TORRE AVENUE•CUPERTINO,CA 95014-3255 (408)777-322 •FAX(408)777-3333•building cacupertino.org �O r Owner Name Permit No. (o Address 1 l y 1. Is your real property a registered historical site? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. 7 No Go to Question 2. 2. Does your real property have a licensed plumber certifying that,due to the age or configuration of the property or its plumbing,installation of water-conserving plumbing fixtures is not technically feasible? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. ❑ The licensed plumber's certification has been provided to the Building Division. Skip the rest of the form and sign bottom of form. No Go to Question 3. 3. Is water service permanently disconnected for your building? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. W No Go to Question 4. 4. Is your real property built and available for use or occupancy on or before January 1, 1994? ❑ No My real property is built and available for use or occupancy after January 1, 1994. Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. Yes My real property is built and available for use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101.8 apply. Check one of the three following statements and sign bottom of form.. 5. Please check ONE of the following: My property is a single-family residential real property. See Civil Code Section 1101.4. On and after January 1, 2014,building alterations or improvements shall require all non-compliant plumbing fixtures to be replaced with water-conserving plumbing fixtures throughout the building.On or before January 1,2017,all non- compliant plumbing fixtures shall be replaced with water-conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements). ❑ My property is a multifamily residential real property. See Civil Code Section 1101.5. On and after January 1, 2014,specified building alterations or improvements shall require non-compliant plumbing fixtures to be replaced with water-conserving plumbing fixtures. On or before January 1,2019,all non-compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building(regardless of whether property undergoes alterations or improvements). ❑ My property is a commercial real property. See Civil Code Section 1101.5. On and after January 1,2014,specified building alterations or improvements shall require non-compliant plumbing fixtures to be replaced with water-conserving plumbing fixtures. On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building(regardless of whether property undergoes alterations or improvements). I,as the owner or owner's agent of this property,certify under penalty of perjury that non-compliant plumbing fixtures will be replaced prior to date specified above with water-conserving plumbing fixtures in accordance with Civil Code Sections 1101.1 through 1101.8,the current California Plumbing Code and California Green Building Standards Code,and manufacturer's installation requirements,and that the water-conserving plumbing fixtures comply with the requirements as indicated in the table on the following page. Owner or Owner Agent's Signature: il Date: IOZ/// Upon completing and signing this Cer i r a e,please return it to the Building Division in order to final your building permit. SB4072015.doc revised 08/26/15 BUILDING PERMIT CANNOT BE FINALED AND COMPLETED UNTIL THIS CERTIFICATE HAS BEEN SI , ED AND RETURNED TO THE BUILDING DIVISION Non-Compliant Water-Conserving Plumbing Fixture PlumbingFixture (Fixture Complying with Current Code Applicable to New Construction) Maximum Water Usage/Flow Rate Fixture Type 2013 CPC Ch. 4 2013 CPC Ch. 4 2013 CPC Ch. 4 Water Usage 2013 CALGreen Div. 4.3 2013 CALGreen Div. 4.3 2013 CALGreen Div. 5.3 /Flow Rate Single-Family Multi-Family Commercial Residential Residential Water Closets Exceed 1.6 Single flush toilets: 1.28 gallons/flush (Toilets) Gallons/flush Dual flush toilets: 1.28 gallons/flush effective flush volume (the composite, avera a flush volume of two reduced flushes and one full flush Urinals Exceed 1.0 0.5 gallons/flush Gallons/flush Showerheads Exceed 2.5 2.0 gallons per minute @ 80 psi. Also certified to the performance criteria of gallons per minute U.S. EPA WaterSense Specification for Showerheads (A hand-held shower is considered a showerhead.) For multiple showerheads serving one shower,the combined flow rate of all showerheads and/or other shower outlets controlled by a single valve shall not exceed 2.0 gallons per minute @ 80 psi, or the shower shall be designed to allow only one shower outlet to be in operation at a time. Faucets— Exceed 2.2 gallons Maximum 1.5 gallons per Within units: 0.5 gallons per minute @ 60 Lavatory per minute minute @ 60 psi; minimum Maximum 1.5 gallons psi Faucets 0.8 gallons per minute @ per minute @ 60 psi; 20 psi minimum 0.8 gallons per minute @ 20 psi In common and public use areas: 0.5 gallons per minute @ 60 psi 1.8 gallons per minute 60 psi Faucets— Exceed 2.2 gallons 1.8 gallons per minute @ 1.8 gallons per minute 1.8 gallons per minute @ 60 Kitchen per minute 60 psi @ 60 psi psi Faucets May temporarily increase May temporarily up to 2.2 gallons per increase up to 2.2 minute @ 60 psi, and must gallons per minute @ default to maximum 60 psi, and must 1.8 gallons per minute @ default to maximum 60 psi 1.8 gallons per minute Where faucets meeting @ 60 psi the above are unavailable, Where faucets meeting aerators or other means the above are may be used to achieve unavailable, aerators or reduction. other means may be used to achieve reduction. 1. If the existing plumbing fixture water usage/flow rate is equal to or lower than the figure shown,it is not required to be upgraded. SB407 2015.doc revised 08/26115