Loading...
15100057 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 10889N DE ANZA BLVD CONTRACTOR:PLATINUM ROOFING INC PERMIT NO: 15100057 OWNER'S NAME: FORGE-VIDOVICH MOTEL LIMITED P 1900 DOBBIN DR DATE ISSUED: 10/07/2015 OWNER'S PHONE: 650-209-32 SAN JOSE,CA 95133 PHONE NO:(408)280-5028 LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL ❑ COMMERCIAL ❑ TEAR OFF(E)ROOF DOWN TO THE DECKING AND INSTALL License Class 13/ C 91 Li..4 -7 9013 (N)60 MIL WITH TPO SINGLE-PLY SYSTEM CLASS A(247 (7// I ff�� SQ) Contractor P4mu& Ln-F;yq Date �Q 1711 , I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. 1 hereby affirm under penalty of perjury one of the following two declarations: Sq.Ft Floor Area: Valuation:$147281 t 1 have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. APN Number:32610058.00 Occul,a nc. 1 k 1,c: 2PAave and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION PERMIT EXPIRES IF WORK IS NOT STARTED 1 certify that 1 have read this application and state that the above information is WITHIN 180 DAYS OF PERMIT ISSUANCE OR correct.I agree to comply with all city and county ordinances and state laws relating 180 DAYS FROM LAST CALLED INSPECTION. to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save �, 1 indemnify and keep harmless the City of Cupertino against liabilities,judgments, Issued b Date: costs,and expenses which may accrue against said City in consequence of the granting of this permit. Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section 9.18. RE-ROOFS: Signature Date /U 711 All roofs shall be inspected prior to any roofing material being installed.if a roof is installed without first obtaining an inspection,I agree to remove all new materials for inspection. ❑ OWNER-BUILDER DECLARATION Signature of Applicant: //✓% L— _ ,- Date: T I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER t 1,as owner of the property,or my employees with wages as their sole compensation,will do the work,and the structure is not intended or offered Ior HAZARDOUS MATERIALS DISCLOSURE sale(Sec.7044,Business&Professions Code) 2 1,as owner of the property,am exclusively contracting with licensed contractors to I have read the hazardous materials requirements under Chapter 6.95 of the construct the project(Sec.7044,Business&Professions Code). California Health&Safety Code,Sections 25505,25533,and 25534. I will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the Health& 1 hereby affirm under penalty of perjury one of the following three declarations: Safety Code,Section 25532(a)should I store or handle hazardous material. t. I have and will maintain a Certificate of Consent to self-insure for Worker's Additionally,should I use equipment or devices which emit hazardous air Compensation,as provided for by Section 3700 of the Labor Code,for the contaminants as defined by the Bay Area Air Quality Management District I will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the performance of the work for which this permit is issued. Health&Safety Code,Sections 25505,25533,and 25534. 2. I have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this Ownero thorized agent: permit is issued. , Z ,� Date: ` a. 1 certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's CONSTRUCTION LENDING AGENCY Compensation laws of California. If,after making this certificate of exemption,I I hereby affirm that there is a construction lending agency for the performance of work's become subject to the Worker's Compensation provisions of the Labor Code,I for which this permit is issued(Sec.3097,Civ C.) must forthwith comply with such provisions or this permit shall be deemed Lender's Name revoked. Lender's Address APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is ARCHITECT'S DECLARATION correct.I agree to comply with all city and county ordinances and state laws relating I understand my plans shall be used as public records. to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save Licensed Professional indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section 9.18. Signature Date REROOF PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 C U P E RT I N O (408)777-3228• FAX(408)777-3333•building aacupertino org I DO� n 9 'N VI'N 3z6- 10 -o ON NLR NAME rq� v%-pIUV fGVL- vAote PHONI I \I\II I \DOBE S j/ CITY, STATE.7111 A �/ _ (I f-� ` Y FAX O -7 \I PIIONI I 6 V ►i''1 S1 RLL-I ADDRESS ( I I Y.STATE,ZIP I \ ❑ (1\\-NIR ❑ OWNER-WILDER ❑ OWNER:\(,I\I ❑ �U\IRU Ii�R I -l��\I It\l IUIt \t d.\I ❑ \It(III H-11 El I1, ❑ UI\IIUI'PK ❑ IFS\VI I-UN"I KA(I OR NAM p A-_ /� �U /../,/�Q I It 1\SI:NUAIBEl� I II-I V0 IN I'I BUS LIC' u COMPANY NAME L�li o E-MAIL FAX ^r'V11f11 STREET ADDRESS D CITY.STATE.ZIP PHONE ARCHI"IECf/ENGINEER NAME LICENSE NUMBER BUS.LIC.N COMPANY NAME E-MAII. FAX S I REST ADDRESS CITI,ST\1 h./II' I'1IO,NI- USE OF ❑ SFD or Duplex Multi-Family I OOI \,tl \ vALUATION STRUCTURE 11Co Commercial �ll EXISTING ROOF TYPE ❑BUILT-UP ROOF ❑ASPHAL I SHINGLES ❑wool)SHAKLS ❑WOOD SHINGLES ❑OTHER(SPECIFY) RFMOVE/REPLACE PQYES IF NO. PLYWOOD '::" ❑ PLYWD 19 OSB PITCH ROOF 171 NO a LAN' THIO'N 13 5/8" TYPE 11CDX :12 CLASS: A P PROPOSED ROOF-rYPE ❑HI91 r-UP ROOF 1:1ASI'H.A LI'SHINGI_IS EI WOOD SHAKE'S ❑WOOD SFIINGI_fiS O'r � � HER0 ICC- OIS(RII'I IDN 1)r N IIRK4n 41-,��a 10r,L/-tnllp- wil c m�wl- CL b'12111mil ✓ f By my signature below,I certify to each of the following: I am the property owner or authorized agent to act on the property o\\ner',lie haIt' I ha\e read thI, application and the information I have provided is co et. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to buil 4101011 1 authorize representatives orCupert ino to enter the above-identified property for inspection purposes. Signature of Applicant/Agenl Date: SUPPLEMENTAL INFORMA-PION REQUIRED OFFIc'F I SI:ON I.1 II'building is associated with a Home Owner's Association,provide letter PLAN(*Ill'( 1.I)PF ROUTING SLIP ofapproval from HOA. ❑ ovFR-I'nF:r'ul.l r.lt ❑ BUILDING PLAN REVIEW Provide Planning approval to verify if there any restrictions. ❑ EXPRESS ❑ PLANNING PLAN REVIEW Provide copy of Manufacturer's Installation Specifications. ❑ STANDARD ❑ FIRE DEPT Provide signed copy of Cupertino's Tear-Oft'Polic). ❑ OTHER: RerooJ:4pp 2011.doc revised 03/16//1 CITY OF CUPERTINO FEE ESTIMATOR — BUILDING DIVISION ADDRESS: 10889 N De Anza Blvd DATE: 10/07/2015 REVIEWED BY: Phuong APN: 326-10-058 BP#: `VALUATION: $147,281 PERMIT TYPE: Minor Building Permit PLAN CHECK TYPE: Re-roof PRIMARY Commercial Building PENTAMATION USE: PERMIT TYPE: 1 COMMLROOF WORK Tear off a roof down to the decking and install N 60 mil TPO Single-ply system Class A 247 SQ SCOPE FEE ID ROOF AREA s.f. 1REROOFCOM 24,700 Li I NOTE: This estimate does not include fees due to other Departments(i.e. Planning,Public Works, Fire,Sanita)y Sewer District,School District,etc. . Thesefees are based on the preliminarl information available and are onh,an estimate. Contact the Dept for addn'l info. FEE ITEMS (l-ce Resolution 11-053 E(1 7 l 13) FEE QTY/FEE MISC ITEMS 'lust ( "r1'L k 1"Cl . �)ippl. 1'('hee I'lumh.!Alec•/.iF,le(• Permit Fee: $1,826.00 ,;,/, F,' /rn ticc h. "lunch. Alec h. l:lec I'crmit Fee.- Work ee:Work Without Permit? O Yes (E) No $0.00 I clvoneed Planning Fees: I Strong Motion Fee: IBSE/SA1lC0 $41.24 Select an Administrative Item Bldg SUN Commission Fcc: IBCBSC $6.00 SUBTOTALS: $1,873.24 $0.00 TOTAL FEE: 1 $1,873.24 Revised: 10/01/2015 c ICC EVALUATION c SERVICE Most Widely Accepted and Trusted ICC-ES Evaluation Report ESR-1463* Reissued July 2014 This report is subject to renewal October 2016. www.icc-es.orq 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council° DIVISION: 07 00 00—THERMAL AND MOISTURE Properties evaluated: PROTECTION ■ Weather resistance Section: 07 53 23—Ethylene-Propylene-Diene-Monomer Roofing ■ Roof covering fire classification Section: 07 54 19—Polyvinyl-Chloride Roofing ■ Wind uplift resistance Section: 07 54 23—Thermoplastic-Polyolefin Roofing ■ Impact resistance REPORT HOLDER: 2.0 USES CARLISLE SYNTEC Carlisle ethylene propylene diene monomer (EPDM), POST OFFICE BOX 7000 polyvinyl chloride (PVC) and thermoplastic polyolefin CARLISLE, PENNSYLVANIA 17013 (TPO) single-ply roofing membranes are used as roof (717)245-7000 coverings in adhered and mechanically fastened www.carlisle-sVntec.com membrane roofing systems. 3.0 DESCRIPTION EVALUATION SUBJECT: 3.1 General: CARLISLE EPDM, PVC AND TPO SINGLE-PL FING The EPDM, PVC and TPO Membrane Roofing Systems MEMBRANES described in this report consist of single-ply roofing membranes, insulation where used, barrier board or slip ADDITIONAL LISTEES: an sheet where used, flashing, mechanical fasteners and adhesives that are installed on a combustible or KELLY COMPANY/2001 INC. 0 noncombustible deck. See Table 1 for Carlisle product 325 THOMASTON AVENUE trade names and corresponding product names for Mule- WATERBURY, CONNECTICUT 06702 Hide Products Company, Inc., WeatherBond, Versico and (203) 575-9220 Kelly Company/2001 Inc., the additional listees. MULE-HIDE PRODUCTS COMPANY, INC. LU 3.2 EPDM Membranes: 1195 PRINCE HALL DRIVE 3.2.1 Sure-Seal: Sure-Seal is a black, nonreinforced BELOIT,WISCONSIN 53511 EPDM membrane,45 mils thick[0.045 inch (1.14 mm)]. (800) 786-1492 3.2.2 Sure-Seal FR: Sure-Seal FR is a black, nonreinforced EPDM membrane with fire retardants. VERSICO Nunn Available thicknesses range from 45 mils (0.045 inch POST OFFICE BOX 1289 [1.14 mm])to 90 mils(0.090 inch [2.29 mm]). CARLISLE, PA 17013 LL (800)992-7663 3.2.3 Sure-White: Sure-White is a white, nonreinforced LL EPDM membrane. It is available in thicknesses of 60 mils WEATHERBONDO [0.060 inch (1.52 mm)]and 90 mils [0.090 inch (2.29 mm)]. POST OFFICE BOX 251 3.2.4 Sure-Tough: Sure-Tough is a black, reinforced PLAINFIELD, PENNSYLVANIA 17081 membrane consistingof a polyester reinforcement (866)471-5125 encapsulated between two EPDM membrane plies. It is available in thicknesses ranging from 45 mils [0.045 inch 1.0 EVALUATION SCOPE (1.14 mm)]to 75 mils [0.075 inch (1.90 mm)]. Compliance with the following codes: 3.2.5 Sure-Tough FR: Sure-Tough FR is a black, ® reinforced membrane consisting of a polyester ■ 2012 and 2009 International Building Code (IBC) reinforcement encapsulated between two EPDM ■ 2012 and 2009 International Residential Code(IRC) membrane plies with fire retardants. Available thicknesses are 45 mils [0.045 inch (1.14 mm)] and 60 mils [0.060 inch ■ Other Codes(see Section 8.0) (1.52 mm)]. 'Revised August 2014 ICC-ES Evaluation Reports are not to be construed as representing aesthetics or am+other attributes not speciftcaQv addressed,nor are thev to be construed OW as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Sen+icB,LLC,express or implied,as ri to a»v finding or other matter in this report,or as to anv product covered by the report. moiiawu Copyright©2014 Page 1 of 10 ESR-1463 I Most Widely Accepted and Trusted Page 2 of 10 3.2.6 Sure-Seal FleeceBACK: Sure-Seal FleeceBACK is 3.4.6 Spectro-Weld: Spectro-Weld is the Sure-Weld a 45-mil to 90-mil [0.045 inch to 0.090 inch (1.14 mm to membrane, described in Section 3.4.1, formulated with a 2.29 mm)] non-reinforced EPDM bonded to a 5.5-ounce- brighter white color. Available thicknesses are 60 mils per-square-yard (0.18 kg/m 2) polyester fleece. Available [0.060 inch (1.52 mm)] and 80 mils [0.080 inch (2.03 mm)]. product thicknesses range from 100 mils [0.100 inch 3.4.7 Spectro-Weld FleeceBACK: Spectro-Weld (2.55 mm)]to 145 mils [0.145 inch (3.68 mm)]. FleeceBACK is the Spectro-Weld membrane with a 3.2.7 Sure-White FleeceBACK: Sure-White FleeceBACK laminated 5.5-ounce-per-square-yard (0.18 kg/m2) is a 45-, 60- or 90-mil [0.045, 0.060 or 0.090 inch (1.14, polyester fleece backing. It is 115 mils [0.115 inch 1.52 or 2.29 mm)] nonreinforced white EPDM bonded to a (2.92 mm)]thick. 5.5-ounce-per-square-yard (0.18 kg/m 2) polyester fleece. 3.5 Insulation: Available product thicknesses are 100, 115 and 145 mils [0.100, 0.115 or 0.145 inch (2.54, 2.92 or 3.68 mm)]. See Tables 2 through 4 for insulations for use with specific roofing systems. Foam plastic insulation, where used, must 3.2.8 Sure-Seal AFX: Sure-Seal AFX is a 45-mil have a flame-spread index of not more than 75 when [0.045 inch (1.14 mm) or 60-mil [0.060 inch (1.52 mm)] tested at the maximum thickness intended for use in non-reinforced EPDM bonded to a 7.5-ounce-per-square- accordance with ASTM E84. yard (0.25 kg/m2) polyester fleece. Available thicknesses are 90 mils [0.090 inch (2.29 mm)] and 105 mils 3.6 Barrier Board: [0.105 inch (2.67 mm)]. Barrier board, where used, must be either minimum 3.3 PVC Membranes: '/4-inch-thick (6.4 mm) G-P Gypsum Corporation "DensDeck," minimum /4-inch-thick (6.4 mm) Owens 3.3.1 Sure-Flex and Sure-Flex KEE: Sure-Flex and Corning "Strataguard", minimum 1/4-inch-thick (6.4 mm) Sure-Flex KEE are membranes consisting of a polyester USG "Securock," or minimum 1/2-inch-thick (12.7 mm) reinforcement encapsulated between two plies of PVC. gypsum board. Barrier board must be UL-listed for roofing The membrane is available in white, gray, tan and custom applications or UL-classified gypsum board. colors. Available thicknesses range from 50 mils 3.7 Slip Sheet: [0.050 inch (1.27 mm)]to 80 mils [0.080 inch (2.03 mm)]. The slip sheet, where used, must include Carlisle "FR 3.3.2 Sure-Flex FRS: Sure-Flex FRS membrane consists Base Sheet 1S or 2S," GAF "VersaShield® Fire-Resistant of a fiberglass reinforcement encapsulated between two Roof Deck Protection (ESR-2053)," Elk "VersaShield plies of PVC.The membrane is available in white, gray and FB-1 S or,FB-2S, or Atlas FR 10 or FR 50." custom colors. Available thicknesses range from 50 mils [0.050 inch (1.27 mm)to 80 mils [0.080 inch (2.03 mm)]. 3.8 fhing: 3.3.3 Sure-Flex FleeceBACK: Sure-Flex FleeceBACK is FlAting,must be provided in accordance with IBC Section the Sure-Flex membrane, described in Sections 3.3.1 and 1503.2 br IRC Section R903.2, as applicable. Where 3.3.2, with a laminated 5.5-ounce-per-square-yard flashing,.is of metal, the metal must be corrosion-resistant, (0.18 kg/m2) polyester fleece backing. Available minimunnkNo. 26 gage [0.019 inch (0.483 mm)] galvanized thicknesses range from 105 mils [0.105 inch (2.67 mm)] steel, s to 135 mils [0.135 inch (3.43 mm)]. 3.9 Fasteners: 3.4 TPO Membranes: Fasteners, used to mechanically attach insulation and 3.4.1 Sure-Weld: Sure-Weld membrane consists of a membranes to the roof deck, must be corrosion-resistant, polyester reinforcement encapsulated between two plies of and must.be Carlisle fasteners, plates or fastening bars, TPO. The membrane is available in white, gray, tan and unless otherwise noted in this report. Refer to Table 4 for custom colors. Available thicknesses range from 45 mils spacing of fasteners. [0.045 inch (1.14 mm)]to 80 mils[0.080 inch (2.03 mm)]. 3.9.1 HP Fastener: This is an epoxy-coated steel screw 3.4.2 Sure-Weld HS: Sure-Weld HS is the Sure-Weld used in combination with Carlisle's fastening plates or bars membrane formulated with an additional flame retardant to mechanically attach roofing insulation and membranes for fire resistance at higher slopes. The membrane is to steel or wood substrate. Fastener length must be available in white, gray, tan and custom colors. Available selected to penetrate through the steel deck a minimum of /4 inch (19.1 mm), and into the wood deck a minimum of thicknesses are 45 mils (0.045 inch [1.14 mm])and 60 mils 1 inch (25.4 mm). (0.060 inch [1.52 mm]). 3.9.2 InsulFast Insulation Fastener: This is an epoxy- 3.4.3 SAT-TPO: SAT-TPO is a self-adhered version of coated steel screw used in combination with Carlisle's the Sure-Weld HS membrane with adhesive. insulation plates to mechanically attach roofing insulation 3.4.4 Sure-Weld FleeceBACK: Sure-Weld FleeceBACK to steel or wood substrates. Fastener length must be is the Sure-Weld HS membrane, 45 mils [0.045 inch selected to penetrate through the steel deck a minimum of (1.14 mm)], 60 mils [0.60 inch (1.52 mm)] and 80 mils /4 inch (19.1 mm), or into the wood deck a minimum of [0.60 inch (2.03 mm)] thick, with a laminated 5.5-ounce- 1 inch (25.4 mm). per-square-yard (0.18 kg/m2) polyester fleece backing. 3.9.3 HP Purlin Fastener: This is an epoxy-coated steel Available thicknesses are 100 mils [0.100 inch (2.54 mm)], screw used in combination with Carlisle's fastening plates 115 mils [0.115 inch (2.92 mm)] and 135 mils [0.135 inch or bars to mechanically attach roofing insulation and (3.43 mm)]. membranes to structural steel members. Fastener length 3.4.5 Sure-Weld AFX: Sure-Weld AFX is the Sure-Weld must be selected to penetrate through the steel member a HS membrane with a laminated 10-ounce-per-square- minimum of 3/4 inch (19.1 mm.) yard (0.34 kg/m2) polyester fleece backing. Available 3.9.4 HD 14-10 Fastener: This is a heavy-duty, epoxy- thicknesses range from 120 mils [0.120 inch (3.05 mm)] to coated steel screw used in combination with Carlisle's 155 mils [0.155 inch(3.94 mm)]. fastening plates or bars to mechanically attach roofing ESR-1463 1 Most Widely Accepted and Trusted Page 3 of 10 insulation and membranes to concrete roof deck. Fastener 3.10 Adhesives: length must be selected to penetrate into the concrete deck a minimum of 1 inch (25.4 mm). 3.10.1 90-8-30A Bonding Adhesive: 90-8-30A Bonding Adhesive is a high-strength, solvent-based contact 3.9.5 CD-10 Fastener: The CD-10 is an epoxy-coated, adhesive used to adhere EPDM membranes to the hammer-driven, nonthreaded fastener specifically insulation or substrate. It has a coverage rate of designed to be used with insulation and seam fastening approximately 60 square feet per gallon (1.5 M2/L). The plates to secure membrane and insulation to structural adhesive is supplied in 5-gallon (18.9 L) containers and concrete. Fastener length must be selected to penetrate has a shelf life of one year. into the concrete deck a minimum of 1 inch (25.4 mm). 3.9.6 Lite-Deck Fastener: The Lite-Deck Fastener is 3.10.2 Aqua Base 120: Aqua Base 120 is a high-strength, used in conjunction with a specially designed 3-inch water-based contact adhesive used to adhere EPDM, TPO (76.2 mm) Lite-Deck Metal Plate for insulation attachment and PVC membranes to the insulation or substrate. It has a coverage rate of approximately 120 square feet per to gypsum, cementitious wood fiber (Tectum (ESR-11121), z gallon (3 m /L). The adhesive is supplied in 5-gallon and lightweight concrete decks. Fastener length must be (18.9 L)containers and has a shelf life of one year. selected to penetrate into the deck a minimum of 2 inches (50.8 mm). 3.10.3 Sure-Flex Low-VOC PVC Bonding Adhesives: 3.9.7 GypTec Fastener: The GypTec Fastener is a Sure-Flex Low VOC PVC Bonding Adhesives is high- glass-filled nylon auger fastener designed for securing strength, solvent-based contact adhesives used to adhere mechanically attached membranes and insulation to PVC membranes to an insulation or substrate. They have gypsum and cementitious wood fiber(Tectum (ESR-11121) a coverage rate of approximately 60 square feet per gallon decks. Fastener length must be selected to penetrate into (1.5 m /L). The adhesive is supplied in 5-gallon (18.9 L) the deck a minimum of 1.5 inches(38.1 mm). containers with a shelf life of one year. 3.9.8 HP Polymer Seam Plate: This is a 2-inch-diameter 3.10.4 Sure-Weld Bonding Adhesive: Sure-Weld (50 mm) polymer plate designed to be used with HP and Bonding Adhesive is a high-strength, solvent-based HD 14-10 fasteners to mechanically attach roofing contact adhesive used to adhere TPO membranes to membranes to the roof deck. an insulation or substrate. It has a coverage rate of 3.9.9 Sure-Tite Fastener and ST Fastening Bar: This is approximately 60 square feet per gallon (1.5 M2/L). The a heavy-duty, epoxy-coated steel screw and bar used to adhesive is supplied in 5-gallon (18.9 L) containers with a secure reinforced EPDM membranes to steel or wood shelf life of one year. deck. The bar is 1-inch-wide-by-0.040-inch-thick-by- 3.10.5 Low VOC Bonding Adhesive: Low VOC Bonding 10-foot-long (25.4 mm by 1.1 mm by 3.1 m) galvalume- Adhesive is a high-strength, solvent-based contact coated steel with prepunched holes 6 inches (150 mm) adhesive used to adhere EPDM and TPO membranes to on center. an insulation or substrate. It has a coverage rate of 3.9.10 HP-X Fastener: This is an epoxy-coated carbon approximately 60 square feet per gallon (1.5 mz/ L). The steel screw used in combination with the Piranha adhesive is supplied in 5-gallon (18.9 L) containers with a Fastening Plate to mechanically attach TPO membranes to shelf life of one year. steel or wood substrate. Fastener length must be selected 3.10.6 HydroBond PVC Water-Based Adhesive: to penetrate through the steel deck a minimum of 3/4 inch HydroBond PVC Water-Based Adhesive is a water-based, (19.1 mm), and into the wood deck a minimum of 1 inch wet lay-in, one-sided adhesive to be used to adhere Sure- (25.4 mm). Flex PVC and PVC FleeceBACK membranes to an 3.9.11 Piranha Fastening Plate: This is a 23/8-inch- insulation or substrate. It has a coverage rate of diameter galvalume-coated steel plate designed to be used 100 square feet per gallon (2.5 M2/L). The adhesive is with HP-X fasteners to mechanically attach PVC and TPO supplied in 5-gallon (918.9 L) containers with a shelf life of membranes to the roof deck. one year. 3.9.12 HP-XTRA Fastener: This is an epoxy-coated 3.10.7 Low VOC Bonding Adhesive 1168: Low VOC carbon steel screw used in combination with the Piranha Bonding Adhesive 1168 is high-strength, solvent-based XTRA Fastening Plate to mechanically attach PVC and contact adhesive used to adhere EPDM and TPO TPO membranes to steel or wood substrate. Fastener membranes to an insulation or substrate. It has a coverage length must be selected to penetrate through the steel rate of approximately 60 square feet per gallon (1.58 M2/L). deck a minimum of 3/4 inch (19.1 mm) and into the wood The adhesive is supplied in 5-gallon (18.9 L) containers deck a minimum of 1 inch (25.4 mm). with a shelf life of one year. 339.13 Piranha XTRA Fastening Plate: This is a 3.10.8 Solvent-Free EPDM Bonding Adhesive: Solvent- 2 /8-inch-diameter galvalume-coated steel plate designed Free EPDM Bonding Adhesive is a high-strength, polymer- to be used with HP-XTRA fasteners to mechanically attach based adhesive. This adhesive can be used to adhere all PVC and TPO membranes to the roof deck. Sure-Seal or Sure-White EPDM membranes as a one- 3.9.14 PVC Oval Barbed Plate: This is a 1'/2-inch-by- sided, wet lay-in adhesive. It has a coverage rate of 23/4-inch (35 mm by 69.85 mm) Oval Barbed Plate 100 square feet per gallon (2.5 M2/L). The adhesive is designed to be used with HP-X Fasteners to mechanically supplied in 5-gallon (18.9 L) containers with a shelf life of attach PVC membranes to the roof deck. six months. 3.9.15 OMG Inc. RhinoBond Plate: The RhinoBond Plate 3.10.9 Cold Applied Adhesive: Cold Applied Adhesive is is a 3-inch-diameter (76.2 mm), 0.028-inch-thick (0.7 mm) a solvent-free, asphalt-modified polyether adhesive. This galvalume-coated steel plate, coated with a proprietary adhesive can be used with all Sure-Seal or Sure-Weld AFX adhesive and used with the HP-X fastener to mechanically membranes as a one-sided, wet lay-in adhesive. It has a attach PVC and TPO membranes to the roof deck. The coverage rate of 67 square feet per gallon (1.6 M2/L). The adhesive bonds the plate to the underside of the adhesive is supplied in 5-gallon (18.9 L) containers with a membrane. shelf life of one year. ESR-1463 [ Most Widely Accepted and Trusted Page 4 of 10 3.10.10 FAST Adhesives: FAST 100, FAST 100LV, tests, provided the resulting classification is the lower of FAST Adhesive Dual Cartridge, FAST Adhesive Box Sets, the new or existing roofing classification: Flexible FAST and FAST Bag-in-a-Box Adhesives are two- ■ New uninsulated systems installed only over existing component polyurethane adhesives used to adhere uninsulated assemblies. FleeceBACK membranes and insulations to various substrates. The adhesives have a coverage rate of ■ New insulated systems installed over existing approximately 100 square feet per gallon (2.5 M21). The uninsulated systems only. adhesives are supplied in 15-gallon (56.7 L) and 50-gallon 4.3 Wind Resistance: (189 L) drums, box sets, and cartridge tubes and cylinders, 4.3.1 New Construction: The allowable wind uplift and have a shelf life of one year. pressures for the EPDM, PVC, and TPO roofing 3.10.11 OlyBond 500 Adhesive: OlyBond 500 Spot Shot membranes as parts of roof assemblies are noted in and OlyBond 500 BA are two-component polyurethane Tables 4 and 5. adhesives used to adhere insulations to various Metal edge securement systems must be listed in substrates. The adhesives have a coverage rate of approximately 100 square feet per gallon (2.5 M2/L). The accordance with ANSI/SPRI ES-1 and designed and installed for wind loads in accordance with IBC Section adhesives are supplied in cartridge tubes and box sets, 1504.5 and IBC Chapter 16. As an alternate to listed metal and have a shelf life of one year. edge securement systems for mechanically attached 3.11 Impact Resistance: membranes, Carlisle SecurEdge 300 [0.050-inch The EPDM, PVC, and TPO roofing membranes described (1.27 mm) 3003 aluminum] and Carlisle SecurEdge 3000 in this report meet requirements for impact resistance in [0.040-inch (1.02 mm)3003 aluminum]fascia systems may IBC Section 1504.7, based on testing in accordance with be used. The maximum allowable load for Carlisle FM 4470. SecurEdge 300 is 234 plf (348 kg/m) and the maximum allowable load for Carlisle SecurEdge 3000 is 200 plf 4.0 INSTALLATION (298 kg/m)based on testing in accordance with ANSI/SPRI 4.1 General: ES-1 Test RE-1. 4.3.2 Reroofing: Mechanically anchored systems may be Installation of the EPDM, PVC, and TPO roofing accepted based on the adequacy of anchors penetrating membranes described in this report must comply with the through existing roof coverings into structural substrates. applicable code, the manufacturer's published installation Since the composition and/or condition of any particular instructions and this report. The manufacturer's published existing underlying material may vary widely, reroofing with installation instructions must be available at all times on adhered systems is outside the scope of this report. the jobsite during installation. 5.0 CONDITIONS OF USE The substrate to which the membrane is to be applied must be clean, dry, and free of frost, loose fasteners, and The single-ply EPDM, PVC, and TPO roofing membranes other protrusions or contaminates that will interfere with the described in this report comply with, or are suitable adhesion or attachment of the membrane or that will alternatives to what is specified in, those codes listed in puncture the membrane. All materials must be protected Section 1.0 of this report, subject to the following against contact with incompatible materials. Where conditions: gypsum board is used as barrier board in the roofing 5.1 Installation must comply with the applicable code, the assembly, weather protection must be provided to prevent manufacturer's published installation instructions and damage to the gypsum board prior to application of the this report. The instructions within this report must roofing membrane. govern if there are any conflicts between the The slope of the roof on which the single-ply membranes manufacturer's installation instructions and this report. are installed must not be more than the maximum slope 5.2 The adhered and mechanically fastened single-ply indicated for the particular assembly as listed in Tables 2 membrane roofing systems must be installed by and 3. professional roofing contractors who are trained and Penetrations and terminations of the roof covering must approved by the manufacturer. be flashed and made weather tight in accordance with the 5.3 Foam plastic insulation must be separated from the requirements of the membrane manufacturer and the interior of the building by an approved thermal barrier applicable code. in accordance with IBC Section 2603.4.1.5 or IRC 4.2 Fire Classification: Section R316.4, as applicable. 5.4 Foam plastic insulation, where used, must bear the 4.2.1 New Construction: The adhered and mechanically label of an approved agency indicating that the foam fastened EPDM, PVC, and TPO single-ply membrane plastic has a flame-spread index of not more than 75 roofing systems, when installed in accordance with this when tested at the maximum thickness intended for report, are Class A, B or C roof covering systems in use in accordance with ASTM E84 or UL 723, subject accordance with ASTM E108 or UL 790, as noted in to the approval of the code official. Tables 2 and 3. 5.5 Design wind uplift pressure on any roof area, 4.2.2 Reroofing: The existing deck must be inspected to including edge and corner zones, must not exceed verify that the structure to be reroofed is structurally sound the allowable wind uplift pressure for the system and adequate to support and secure the roofing installed in that particular area. Refer to allowable membrane. Prior to installation of new roof coverings, wind uplift pressures for systems as listed in Table 4. inspection by and written approval from the code official 5.6 The allowable wind uplift pressures listed in Table 4 having jurisdiction must be required. are for the roof covering system only. The deck and Class A, B or C roof covering systems may be installed framing to which the system is attached must be over existing classified roof covering systems under the designed for the applicable components and cladding following conditions without additional roof classification wind loads in accordance with the applicable code. ESR-1463 I Most Widely Accepted and Trusted Page 5 of 10 5.7 When application is over existing roofs, 3.8 Flashing: documentation of the wind-uplift resistance of the Flashing must be provided in accordance with SBC composite roof construction must be submitted to the Section 1503.2, BNBC Section 1508.1 and UBC Section code official for approval at the time of permit 1509, as applicable. Where flashing is of metal, the metal application. must be corrosion-resistant, minimum No. 26 gage 5.8 The roofing membranes are manufactured at Carlisle, [0.019 inch (0.483 mm)] galvanized steel. Pennsylvania; Greenville, Illinois; Tooele, Utah; and 3.11 Impact Resistance: Senatobia, Mississippi, under a quality control program with inspections by ICC-ES. The EPDM, PVC, and TPO roofing membranes described 5.9 For buildings under the IBC, above-deck thermal in this report meet requirements for impact resistance in insulation board must comply with the applicable BNBC Section 1505.4.2, and SBC Section 1504.6, based standards listed in IBC Table 1508.2 or IRC Table on testing in accordance with FM 4470. R906.2, as applicable. 4.3.1 New Construction: The allowable wind uplift 6.0 EVIDENCE SUBMITTED pressures for the EPDM, PVC, and TPO roofing membranes as parts of roof assemblies are noted in Data in accordance with ICC-ES Acceptance Criteria Tables 4 and 5. for Membrane Roof Covering Systems (AC75), dated 5.0 CONDITIONS OF USE July 2010 (editorially revised April 2014). 7.0 IDENTIFICATION The single-ply EPDM, PVC, and TPO roofing membranes described in this report comply with, or are suitable Each roll of the roofing membrane must bear a label noting alternatives to what is specified in, those codes listed in the product name, the manufacturer's name (Carlisle Section 8.0 of this report, subject to the following SynTec) or the name of the additional listee, the conditions: manufacturer's address or plant code and the ICC-ES See Sections 5.1 through 5.8, except revise Section 5.3 evaluation report number(ESR-1463). to read as follows: 8.0 OTHER CODES 5.3 Foam plastic insulation must be separated from the In addition to the codes referenced in Section 1.0, the interior of the building by an approved thermal barrier in products in this report were evaluated for compliance with accordance with BNBC Section 2603.4.1.5, SBC Section the requirements of the following codes: 2603.5.1.5, and UBC Sections 2602.4 and 2602.5.3, as ■ BOCA®National Building Code/1999 (BNBC) applicable. ■ 1999 Standard Building Codec(SBC) ■ 1997 Uniform Building Code TM (UBC) For compliance under the above codes, see Sections 2 through 7 of this report, except revise the following sections to read as follows: ESR-1463 I Most Widely Accepted and Trusted Page 6 of 10 TABLE 1—PRODUCT NAMES ./ CARLISLE KELLY CO./ INC. MULE-HIDE VERSICO PRODUCT NAME WEATHERBOND PRODUCT NAME PRODUCT NAME PREMIUM,C-EPDM-C MVersigard Non-reinforced EPDM WeatherBond RBR EPDM Non- Sure-Seal STANDARD ule-Hide Standard EPDM Membrane reinforced Membrane Sure-Seal FR C-EPDM-C Mule-Hide FR EPDM VersiGard FR Nonreinforced WeatherBond RBR FR EPDM EPDM Non-reinforced Membrane Sure-Seal FleeceBACK PREMIUM VersiFleece EPDM Membrane Sure-Seal AFX VersiFleece AC EPDM Membrane Sure-Tough Reinforced PREMIUM,C-EPDM-C, Mule-Hide Standard Versigard Reinforced WeatherBond RBR Standard STANDARD,C-EPDM-CR Reinforced EPDM EPDM Membrane Reinforced EPDM Membrane Sure-Tough FR C-EPDM-CR Type 1 Mule-Hide FR Reinforced VersigardFR Reinforced WeatherBond RBR FR Reinforced EPDM Reinforced EPDM Membrane Sure-White PREMIUM,EPDM RF- Mule-Hide White-on-Black Versigard Nonreinforced EPDM WeatherBond RBR White White EPDM -White EPDM Membrane Sure-White FleeceBACK Sure-Weld Reinforced TPO/White TPO Mule-Hide TPO-c Versiweld Reinforced TPO WeatherBond PRO TPO Membrane Membrane Sure-Weld HS Mule-Hide TPO-c(FR) Versiweld ES SAT-TPO Mule-Hide SA-TPO Versiweld QA TPO WeatherBond PRO PAS TPO Sure-Weld Mule-Hide TPO-c Fleece VersiFleece TPO Membrane FleeceBACK Back Sure-Weld AFX Mule-Hide TPO-C Fleece VersiFleece AC TPO Membrane Back Plus Spectro-Weld Spectro-Weld FleeceBack Sure-Flex Mule-Hide PVC Membrane VersiFlex Reinforced PVC WeatherBond PRO PVC Membrane Sure-Flex KEE VersiFlex-E PVC Membrane Sure-Flex FRS Mule-Hide FRS PVC VersiFlex FRS Reinforced PVC Membrane Membrane Sure-Flex FleeceBack VersiFleece PVC Membrane 90-8-30A Bonding 2001 Inc.Bonding Adhesive Mule-Hide Bonding Adhesive G200SA Yellow Substrate WeatherBond RBR LC-60 Adhesive Adhesive Bonding Adhesive Solvent-Free EPDM Solvent-Free EPDM Bonding Solvent-Free EPDM Bonding Bonding Adhesive Adhesive Adhesive Aqua Base 120 Mule-Hide WBBA-2000 Aqua Base 120 Bonding Aqua Base 120 Bonding Bonding Adhesive Bonding Adhesive Adhesive Adhesive Sure-Weld Bonding Mule-Hide TPO-c Bonding Versiweld Bonding Adhesive WeatherBond PRO TPO Adhesive Adhesive Bonding Adhesive Low VOC Bonding Mule-Hide Low VOC Bonding LOW VOC Bonding Adhesive LOW VOC Bonding Adhesive Adhesive Adhesive Low VOC Bonding Low VOC Bonding Adhesive Low VOC Bonding Adhesive Adhesive 1168 1168 1168 Sure-Flex Low VOC Mule-Hide Low VOC PVC VersiFlex Low VOC PVC WeatherBond Low VOC PVC PVC Bonding Adhesive Bonding Adhesive Bonding Adhesive Bonding Adhesive HydroBond PVC Water- HydroBond PVC Water-Based HydroBond PVC Water-Based Based Adhesive Adhesive Adhesive Cold Applied Adhesive Cold Applied Adhesive - FAST 100 Adhesive Mule-Hide SP-100 Adhesive FAST 100 Adhesive FAST 100 LV Adhesive Mule-Hide SP-100-LT FAST 100 LV Adhesive - Adhesive OlyBond 500 Adhesive OlyBond 500 Adhesive OlyBond 500 Adhesive ESR-1463 I Most Widely Accepted and Trusted Page 7 of 10 TABLE 2—FIRE CLASSIFICATION ASSEMBLIES—ADHERED ROOFING SYSTEMS"' SYSTEM ROOF DECK BARRIER BOARD INSULATION' MEMBRANE/MAX. ROOF SLOPE NO. CLASS OR SLIP SHEET Any of the following insulations, Sure-Weld,Spectro-Weld-'/4:12 1-inch min.to 6-inch max. Sure-Seal,Sure-Tough,Sure-White,Sure- thickness:Carlisle"SecurShield Seal FleeceBACK,Sure-Weld HS,SAT-TPO, 1 A Noncombustible Polyiso","Polyiso HP-H", Hunter Sure-Weld FleeceBACK, Spectro-Weld Panels"H-Shield"or FleeceBACK- /2:12 Sure-White FleeceBACK,Sure-Flex,Sure- "H-Shield-CG" Flex FRS-'/4:12 1/2-inch-thick fiberboard 4, 'l2-inch Sure-White FleeceBACK-'/4:12 thick fiberboard or barrier board Sure-Seal,Sure-Tough- /4:2 (see Section 3.6)over 5-inch Sure-White,Sure-Seal FleeceBACK,Sure- 2 A Noncombustible — max Iberbo rd EPS , /2 inch- Weld,Spectro-Weld,Sure-Weld HS, SAT- thick fiberboard or barrier board TPO,Sure-Weld FleeceBACK,Spectro-Weld (see Section nsu over System FleeceBACK,Sure-Flex,Sure-Flex FRS- No. 1 insulations 11/2:12 Sure-White FleeceBACK-'/4:12 Noncombustible or Sure-White,Sure-Seal FleeceBACK-11/2:12 Combustible-min. Sure-Tough,Sure-Weld,Spectro-Weld,Sure- 3 A 15/32-inch-thick Barrier board — Weld FleeceBACK,Spectro-Weld plywood or min. (see Section 3.6) FleeceBACK-3:12 7/16-inch-thick OSB. Sure-Weld HS,SAT-TPO-4:12 Sure-Seal FR,Sure-Flex,Sure-Flex FRS– unlimited slope Any of the following insulations, Sure-Weld,Spectro-Weld-'/4:12 Combustible-min. Barrier board 1-inch min. Sure-Seal,Sure-Tough,Sure-White,Sure- 15/32-inch-thick (see Section 3.6)or to 6-inch max.thickness: Seal FleeceBACK,Sure-Weld HS,SAT-TPO, 4 A min. Slip sheet:2 layers Carlisle"SecurShield Polyiso", Sure-Weld FleeceBACK,Spectro-Weld plywood -t ' plinch-thick OSB. (see Section 3.7) Polyiso HP-H", FleeceBACK- /2:12 Hunter Panels"H-Shield"or Sure-White FleeceBACK,Sure-Flex,Sure- "H-Shield-CG" Flex FRS-3/4:12 Combustible-min. Any of the following insulations, 5/32-inch-thick _ 2-inch min.to 6-inch max. Sure-Weld,Sp re-Fl Weld,Sure-Weld HS, 5 C plywood or min. thickness:Carlisle"Polyiso HP- SAT-TPO,Sure-Flex,Sure Flex FRS– '/16-inch-thick OSB. H"or Hunter Panels"H-Shield" unlimited slope Single layer of minimum 3.0"or double layer of minimum 1.5" 6 A Combustible — Carlisle"SecurShield Polyiso"or EPDM, PVC,and TPO Membranes-'/2:12 Hunter Panels "H-Shield-CG" Single layer of minimum 1.9" 7 B Combustible — Carlisle"SecurShield Polyiso"or EPDM, PVC,and TPO Membranes-'/2:12 Hunter Panels "H-Shield-CG" For SI: 1 inch=25.4 mm. 'All foam plastic insulation must be UL-classified foamed plastic for roofing systems,and must be limited to the maximum thickness in accordance with Section 5.4 of this report or the maximum thickness in accordance with this table,whichever is less. 2See Section 3.10 for adhesive application rate. 3 U Classified EPS may be installed below min. 1-inch-thick Carlisle or Hunter Panels polyisocya nu rate insulations(max slope 1:12)or below min.'/2-inch-thick Carlisle SecurShield HD or Hunter Panels H-Shield HD(max slope 2:12)on noncombustible decks. 'Carlisle SecurShield HD or Hunter Panels H-Shield HD may replace fiberboard and may be used as a coverboard over any insulation.When these two boards are used directly below the Sure-Weld membrane,the slope is limited to max. 1/2:12. 5When these systems are used for reroofing or recovering,installation must be in accordance with Sections 4.2.2 and 5.7 of this report, and IBC Section 1510, IRC Section R907,BNBC Section 1512,SBC Section 1510 or UBC Appendix to Chapter 15,as applicable. ESR-1463 I Most Widely Accepted and Trusted Page 8 of 10 TABLE 3—FIRE CLASSIFICATION ASSEMBLIES—MECHANICALLY FASTENED ROOFING SYSTEMS` SYSTEM ROOF BARRIER BOARD 1 MEMBRANE/MAX. ROOF NO. CLASS DECK OR SLIP SHEET INSULATION SLOPE Any of the following insulations, 1-inch min.to Sure-Tough,Sure-Weld, 1 A Noncombustible — 6-inch max.thickness:Carlisle"SecurShield Spectro-Weld,Sure-Flex,Sure- ex FRS-'/2:12 Polyiso"or"Polyiso HP-H", Hunter Panels"H- FSurelWeld HS-1'/2:12 Shield"or"H-Shield-CG" Sure-Tough FR-2:12 1/2-inch-thick fiberboard 3, '/2-inch-thick Sure-Tough,Sure-Weld HS, fiberboard or barrier board(see Section 3.6) Sure-Flex,Sure-Flex FRS-1:12 2 A Noncombustible — over 5-inch max Insulfoam EPS2,'/2-inch-thick Sure-Weld,Spectro-Weld- fiberboard or barrier board(see Section 3.6) 11/2:12 over System No. 1 insulations Sure-Tough FR-31/2:12 Sure-Weld,Spectro-Weld,Sure- 3 A Noncombustible — To 5-inch max: Insulfoam SP Weld HS, Sure-Flex,Sure-Flex FRS-'/2:12 Noncombustible or Sure-Tough,Sure-Weld, Combustible-min. Spectro-Weld-3:12 is Barrier board 4 A /32-inch-thick — Sure-Tough FR-31/2:12 (see Section rd plywood or min. Sure-Weld HS,Sure-Flex,Sure- '/16-inch-thick OSB. Flex FRS-unlimited Combustible-min. Barrier board Any of the following insulations, 1-inch min. Sure-Tough,Sure-Weld, s (see Section 3.6) to 6-inch max.thickness:Carlisle Spectro-Weld, Sure-Flex,Sure- s A inch-thick or Slip sheet:2 "SecurShield Polyiso"or"Polyiso HP-H", Flex FRS-'/2:12 7/plywood or min.,6-inch-thick OSB. layers, Hunter Panels Sure-Weld HS, 11/2:12 (see Section 3.7) "H-Shield"or"H-Shield-CG" Sure-Tough FR-2:12 Combustible-min. Sure-Tough-1:12 1$/32-inch-thick Slip sheet,2 layers Sure-Tough FR, Sure Weld, 6 A plywood or min. (see Section 3.7) — Spectro-Weld,Sure-Weld HS, '/,6-inch-thick OSB Sure-Flex,Sure-Flex FRS- 1 /2:12 Combustible-min. Sure-Tough,Sure-Tough FR, 7 B 15/32-inch-thick Slip sheet, 1 layer _ Sure-Weld,Spectro-Weld, plywood or min. (see Section 3.7) Sure-Weld HS, Sure-Flex,Sure- '/16-inch-thick OSB. Flex FRS-1'/2:12 Combustible-min. Any of the following insulations,2-inch min. s to 6-inch max.thickness:Carlisle Sure-Weld,Spectro-Weld, 8 C inch-thick — "SecurShield Polyiso"or"Polyiso Sure-Weld HS, Sure-Flex,Sure- 7/16-inch-thick or min./,6-inch thick OSB. HP-H", Hunter Panels"H-Shield" Flex FRS-unlimited or H-Shield CG" Single layer of minimum 3-inch or double layer of minimum 1.5-inch Carlisle EPDM, PVC,and TPO 9 A Combustible — "SecurShield Polyiso"or Membranes-'/2:12 Hunter Panels"H-Shield-CG" Single layer of minimum 1.9-inch Carlisle "SecurShield Polyiso"or Hunter Panels EPDM, PVC,and TPO 10 B Combustible — "H-Shield-CG"or single layer of an inverted Membranes-'/2:12 G3 cap sheet. For SI: 1 inch=25.4 mm. 'All foam plastic insulation must be UL-classified foamed plastic for roofing systems,and must be limited to the maximum thickness in accordance with Section 5.4 of this report or the maximum thickness in accordance with this table,whichever is less. 2 U Classified EPS may be installed below min. 1-inch-thick Carlisle or Hunter Panels polyisocyanurate insulations(max slope 1:12)or below min.'/2-inch-thick Carlisle SecurShield HD or Hunter Panels H-Shield HD(max slope 2:12)on noncombustible decks. 3Carlisle SecurShield HD or Hunter Panels H-Shield HD may replace fiberboard and may be used as a coverboard over any insulation.When these two boards are used directly below the Sure-Weld membrane,the slope is limited to'/2:12. °When these systems are used for reroofing or recovering,installation must be in accordance with Sections 4.2.2 and 5.7 of this report,and IBC Section 1510, IRC Section R907, BNBC Section 1512,SBC Section 1510 or UBC Appendix to Chapter 15,as applicable. ESR-1463 I Most Widely Accepted and Trusted Page 9 of 10 TABLE 4—WIND RESISTANCE—MECHANICALLY FASTENED ASSEMBLIES"' MAXIMUM MAXIMUM MAXIMUM SYSTEM ALLOWABLE DECK INSULATION a s MEMBRANE MEMBRANE FASTENER FASTENER NO. WIND UPLIFT FASTENING SPACING ROW (psf) (inches) SPACING' Foam plastic insulation'2, 1 45 Noncombustible /2-inch-thick fiberboard or Sure-Tough HP-X Fastener& 12 6 ft 6 inches barrier board Metal Fastening Bar (See Sect.3.6) 2 75 Noncombustible Same as System No.1 Sure-Tough HP-X Fastener& 6 6 ft 6 inches Metal Fastening Bar 3 52 Noncombustible Same as System No. 1 Sure-Tough HP Fastener& 6 9 ft 6 inches Polymer Seam Plate 4 45 Noncombustible Same as System No.1 Sure-Tough Sure-Tite Fastener& 12 9 ft 6 inches ST Fastening Bar 5 30 Noncombustible Same as System No.1 Sure-Tough HP Fastener& 12 9 ft 6 inches (75 mil) Polymer Seam Plate 6 60 Noncombustible Same as System No.1 Sure-Tough HP Fastener& 6 9 ft 6 inches (75 mil) Polymer Seam Plate Sure-Weld or HP-X or HP-Xtra 7 45 Noncombustible Same as System No.1 Spectro-Weld Fasteners with Piranha 12 7 ft 6 inches or Piranha Xtra Plates 8 45 Noncombustible Same as System No.1 Sure-Weld or HP-Xtra Fasteners with 12 9 ft 6 inches Spectro-Weld Piranha Xtra Plates HP-X or HP-Xtra 9 60 Noncombustible Same as System No. 1 Sure-Weld or Fasteners with 6 9 ft 6 inches Spectro-Weld Piranha or Piranha Xtra Plates Sure-Weld or HP-X or HP-Xtra 10 67 Noncombustible Same as System No. 1 Spectro-Weld Fasteners with Piranha 6 7 ft 6 inches or Piranha Xtra Plates Sure-Weld or HP-X or HP-Xtra 11 30 Noncombustible Same as System No. 1 Spectro-Weld Fasteners with Piranha 12 11 ft 6 inches or Piranha Xtra Plates Sure-Weld or HP-X or HP-Xtra 12 60 Noncombustible Same as System No.1 Spectro-Weld Fasteners with Piranha 6 11 ft 6 inches or Piranha Xtra Plates 13 53 Noncombustible Same as System No. 1 Sure-Flex HP-X Fasteners with 6 6 ft 4 inches Piranha Plates 14 83 Noncombustible Same as System No. 1 Sure-Flex HP-X Fasteners with 6 2 ft 11 inches Piranha Plates HP-X or HP-Xtra 15 30 Noncombustible Same as System No. 1 Sure-Flex Fasteners with Piranha 18 6 ft 4 inches or Piranha Xtra Plates HP-X or HP-Xtra 16 45 Noncombustible Same as System No. 1 Sure-Flex Fasteners with Piranha 12 6 ft 4 inches or Piranha Xtra Plates 17 53 Noncombustible Same as System No.1 Sure-Flex HP-X Fasteners with 12 2 ft 11 inches Piranha Plates 18 45 Noncombustible Same as System No.1 Sure-Weld HP-X Fasteners with 1 per 5.3 ft2 N/A OMG RhinoBond Plates 19 60 Noncombustible Same as System No.1 Sure-Weld HP-X Fasteners with 1 per 4 ft2 N/A OMG RhinoBond Plates For SI: 1 inch=25.4 mm; 1 ft=0.305 m; 1 psf=47.88 Pa. 'Foam plastic insulation must be any of the following(1-inch min.to 6-inch max.thickness):Carlisle"SecurShield Polyiso","Polyiso HP-H"Hunter Panels "H-Shield"or Hunter Panels"H-Shield-CG". 2All foam plastic insulation must be UL-classified foamed plastic for roofing systems,and must be limited to the maximum thickness in accordance with Section 5.4 of this report or the maximum thickness in accordance with this table,whichever is less. 'Steel deck must be minimum No.22 gage galvanized steel[base-metal thickness 0.030 inch(0.76 mm)].Concrete must have a minimum compressive strength(f,)of 2500 psi.See Section 5.6 of this report. 'For existing metal roofing,the assemblies listed must be installed by fastening through the roofing and into structural members(purlins,angle iron,beams, etc.)capable of resisting all expected loads.The maximum allowable wind uplift(field)pressures are shown in Column 2. 5UL Classified EPS may be installed below min.1-inch-thick Carlisle or Hunter Panels polyisocyanurate insulations(max slope1:12)or below min.'/2-inch- thick Carlisle SecurShield HD or Hunter Panels H-Shield HD(max slope 2:12)on noncombustible decks. 6 Carlisle SecurShield HD or Hunter Panels H-Shield HD may replace fiberboard and may be used as a coverboard over any insulation.When these two boards are used directly below the Sure-Weld membrane,the slope is limited to 1/212. 'When these systems are used for reroofing or recovering,installation must be in accordance with Sections 4.2.2 and 5.7 of this report,and IBC Section 1510,IRC Section R907,BNBC Section 1512,SBC Section 1510 or UBC Appendix to Chapter 15,as applicable. 6 Fastener row spaces shown are for field of roof only.See Section 4.3 for recognized fascia systems for mechanically fastened roof assemblies.The maximum allowable load for Carlisle SecurEdge 300 is 234 plf(348 kg/m).The maximum allowable load for Carlisle SecurEdge 3000 is 200 plf (298 kg/m). Distance between the edge of the roof and the first row of fasteners must be determined accordingly. ESR-1463 I Most Widely Accepted and Trusted Page 10 of 10 TABLE 5—WIND RESISTANCE—ADHERED ASSEMBLIES' ALLOWABLE INSULATION SYSTEM WIND UPLIFT DECK' INSULATION/MIN.THICKNESS''' FASTENING MEMBRANE NO. (FIELD)(psf) RATE TYPE 1 45 Combustible or 1/2 inch fiberboard 4,15/32 inch OSB,or barrier board 1er 2 ft2 EPDM,PVC and TPO Noncombustible (See Section 3.6) p Membranes Carlisle"Polyiso HP-H"or"SecurShield Polyiso"; 2 45 Combustible or Hunter Panels"H-Shield"or"H-Shield-CG"/1.4 inch 1 per 3.2 ft EPDM, PVC and TPO Noncombustible with'/2-inch Securock coverboard(optional) Membranes Carlisle"Polyiso HP-H"or"SecurShield Polyiso'; 3 45 Combustible or Hunter Panels"H-Shield"or"H-Shield-CG"/2.0 inch 1 per 4 ft2 EPDM, PVC and TPO Noncombustible with 5/8-inch Securock coverboard(optional) Membranes 4 68 Combustible or Carlisle"Polyiso HP-H"or"SecurShield Polyiso"; FAST Adhesive FleeceBACK Membranes Noncombustible Hunter Panels"H-Shield"or"H-Shield-CG"/1.0 inch Carlisle"Polyiso HP-H"or"SecurShield Polyiso"; 5 75 Combustible or Hunter Panels"H-Shield"or"H-Shield-CG"/2.0 inch 1 per 1.6 ft2 EPDM, PVC and TPO Noncombustible with'/2-inch Securock coverboard(optional) Membranes TPO Membranes; 6 120 Combustible or Carlisle"Polyiso HP-H"or"SecurShield Polyiso"; 1er 1 ft EPDM membranes Noncombustible Hunter Panels"H-Shield"or"H-Shield-CG"/2.0 inch p (with noncombustible deck only) Combustible or Carlisle"Polyiso HP-H"or"SecurShield Polyiso'; 2 EPDM and TPO 7 128 Noncombustible Hunter Panels"H-Shield"or"H-Shield-CG"/2.0 inch 1 per 1 ft Membranes with /2-inch Securock coverboard(optional) Combustible or Carlisle"Polyiso HP-H"or"SecurShield Polyiso"; 8 135 Noncombustible Hunter Panels"H-Shield"or"H-Shield-CG"/2.0 inch 1 per 1 ft2 FleeceBACK Membranes with /2-inch Securock coverboard(optional) 9 143 Combustible or '/2 inch DensDeck Prime 1 per 1 ft2 FleeceBACK Membranes Noncombustible For SI: 1 inch=25.4 mm; 1 ft=0.305 m; 1 psf=47.88 Pa 'All foam plastic insulation must be UL-classified foamed plastic for roofing systems,and must be limited to the maximum thickness in accordance with Section 5.4 of this report or the maximum thickness in accordance with this table,whichever is less. 2Steel deck must be minimum No.22 gage galvanized steel(base-metal thickness 0.030 inch(0.76 mm)]. Concrete must have a minimum compressive strength(F.)of 2500 psi.See Section 5.6 of this report. 'UL Classified EPS may be installed below min. 1-inch-thick Carlisle or Hunter Panels polyisocyanurate insulations(max slope 1:12)or below min.'/2-inch-thick Carlisle SecurShield HD or Hunter Panels H-Shield HD(max slope 2:12)on noncombustible decks. 'Carlisle SecurShield HD or Hunter Panels H-Shield HD may replace fiberboard and may be used as a coverboard over any insulation.When these two boards are used directly below the Sure-Weld membrane,the slope is limited to 1/2:12. 'When application is over existing roofs, documentation of the wind-uplift resistance of the composite roof construction must be submitted to the code official for approval at the time of permit application. For reroofing or recovering, installation must be in accordance with IBC Section 1510, IRC Section R907,BNBC Section 1512,SBC Section 1510 or UBC Appendix to Chapter 15,as applicable.