13120165 - AMMR ALTERNATE MATERIALS AND METHODS I MODIFICATION FORM COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION 10300 TORRE AVENUE•CUPERTINO,CA 95014-3255 (408)777-3228•FAX(408)777-3333•building0cuoertino.ora CUPERTINO 13 REQUEST FOR MODIFICATION OF CODE(CBC 104.10,CFC 104.8) O REQUEST FOR ALTERNATE MATERIAL,DESIGN OR METHOD OF CONSTRUCTION(CBC 104.11,CFC 104.9) IN REQUEST FOR HARDSHIP EXEMPTION OR EQUIVALENT FACILITATION(HEALTH AND SAFETY CODE 19957) To apok for#tis reatest.coinviate sections 1;Z 8 3 fink or SITEADDRESS Steven Creek Blvd, APN M41-027 DATE 08✓ MA15 Owner. -0q- Cerrter eur>i!F ..... .. PG#. Type: .!-A ......... .... ..................... .... ........ A 20400 Stevens Creek BOU�eVaRt ............................................................. Pemvt#•.�E rt�K. tones. 8.............................. t3eai. �CdJprom.!heusre0.com..........Phone.408.673.0121.. ................... PLN#.LIST d M .8 � .................. .. ...............F......... panty.......:................... IGm BledcsaM,Interests,Inc. CA Dept.Niv.CDD/MQ.......... Floor Area..................... Applicant........_............ ..Title.......`�`�...................... ........ Permitted 1040 Main Sheet Suite 105 Job Status:........................... Occ.Load;............................ Address......... ..................................................................................I..........I................. .........» � Cmatldrmemac.com Phana.707.255.576 !� .......... ...... .. 2 1 REQUEST: For coda"w0cations,please state the appicabb colt requkenwm and the extent of rater desired. For alternate requests,state the type of system proposed and design mettads. Submkplwu Itnecesambillustrete request Additional sheets or data maybe attached. accessible'toilet stalls.Th*s request is describ I ed in detail on the itflached letter,This condition affects numerous permits whose numbers are attached 3 JUSTIFICATIONWINDINGS OF EQUIVALENCY: For cab modpcations,applicant shd dananstrate that Code Secdon(s): special,kWWklrrsi reasom exist that make compliance wih ere strict tetter d fhe ordtrumoe Nnpracikai and that egrdvatency is provided. For aitemate requests,appvcwt shalt d--mbate suitabiity.s wvtt%etbcttvo*n.fire CBC 11-202.3 resistance duratoky.safely and sanitation that is emmyslark b the code for a skniar use. Attach additional sheets If necessaryl. r. 202.3.exception 1.This mail enc ee attached letter and drawing) and the areis still usable by a wheelchair user trying to exit the stall I'm an electric wheelchair user and fou a -encroachment did not present a barrier), [See atoched letter] petkion$ eeTI:...:.. ......:. Posftn%!;/1,'P� 021 Date 8�I R Date ...�. ..� .. The Request is FI GRANTED 13 DEED en ; CONDITIONS OF APPROVAL- No.of Items:.........I..................... Fee Due:;....t.3..................... Date Paid ................................ Receipt No................................ n^� Processed beryl... 1 ............. BuildingOfficial: ...Y...V..l......................................................Print.. `7.!."Y....1..... i.r.hi`.. Date:._v`f..I.!..I�j. Fire Marshal:......................................:.................._..........................Print:.................................................................................Date:.......... ..» ............... . DEPARTMENT ACTION: After determinaticm,copies to:1)applicant 2)permit lila Al anrr _701 S.doc revised 07/01/15 Permits for restroom accessibility upgrades under the 2010 California Building Code. APN- 369.01.028 20400 Stevens Creek Blvd Permit# Applied 1st Floor 13120165 12/19/2013 2nd Floor 13120165 12/19/2013 3rd Floor 13120159 12/19/2013 4th Floor 13120159 12/19/2013 5th Floor 13080146 8/20/2013 6th Floor 13080146 8/20/2013 7th Floor 12050091 5/8/2013 8th Floor 12050091 5/8/2013 369-01- APN - 027 20450 Stevens Creek Blvd 1st Floor* 13120163 12/19/2013 2nd Floor 13080145 8/20/2013 3rd Floor 13080145 8/20/2013 4th Floor 13120161 12/19/2013 5th Floor 13120161 12/19/2013 6th Floor** 14040091 4/15/2014 7th Floor 13120164 12/19/2013 8th Floor 13120164 12/19/2019 Kim R. Black th Interests,se to ests, Inc: 1040 Main Street Suite 105 Napa, CA 94559 Phone 707-255-5576 August 11, 2015 Albert Salvador, P.E., C.B.O. Building Official City of Cupertino 10300 Torre Ave. Cupertino, CA 95014 Email:AlbertS@cupertino.org RE: 20400-20450 Steven's Creek Blvd- Restrooms Dear Mr. Salvador, As I discussed with your office,we are asking for a finding of"technically infeasible" for the subject restrooms. The existing restroom condition does not allow full compliance with the accessible toilet stall configuration, as outlined in the CBC (and ADA). We have attached this letter to the ALTERNATE MATERIALS AND METHODS/MODIFICATIONS form, as directed. The request and justifications areas of the form were limited in space, so please accept this description. The maneuvering space required for exiting the stall is 44" deep (from the face of the door).This existing space is about 8" short in the far corner of the required rectangular clear area. This condition is caused by a structural member, which does not allow full compliance and has little likelihood of being accomplished. The condition is shown attached below. This is condition meets the definition of"Technically Infeasible" and was exactly the reason this provision was included. The ADA 2010 Standards, as well as the CBC 11-202.3, allow for an exception, (see Section 202.3): (j)EXCEPTION.In alteration work, if compliance with 4.1.6 is technically infeasible, the alteration shall provide accessibility to the maximum extent feasible. The operative definition is as follows: Professional Strategies and Solutions for Disabled Access www.blackseth.com Technically Infeasible-Means,with respect to an alteration of a building or a facility, that it has little likelihood of being accomplished because existing structural conditions would require removing or altering a load-bearing member which is an essential part of the structural frame; or because other existing physical or site constraints prohibit modification or addition of elements, spaces,or features which are in full and strict compliance with the minimum requirements for new construction and which are necessary to provide accessibility. (Emphasis added) In summary, due to the discussion above, we do not believe it would be technically feasible to provide a compliant latch side approach,but it currently meets the applicable requirements. The applicant respectfully requests a formal finding of"Technical Infeasibility" and have the findings entered into the files of the enforcing agency, per 1113-202.3.. Yours truly, 1 Kim R.Blackseth, ICC, CASp State of California Certified Access Specialist (CASp #021) State of California Building Standards Commissioner(2006-2007) California Board for Professional Engineer and Land Surveyors (2007-11) International Conference of Building Officials # 1085694-12 ICC Certified Accessibility Inspector/Plans Examiner#20112 Member of the Western Region Master Builders Association California General Building Contractor# 363311, since 1978 Attachment 2 54" MIN to be code compliant .811 t I � 51.011 ' V1' LATCH APPROACH, PUSH SIDE APPROXIMATE LOCATION OF STEEL COLUMN 3 Lopez, Marni From: Lopez, Marni Sent: Thursday, September 17, 2015 12:12 PM To: Albert Salvador Cc: kimblackseth@mac.com Subject: RE:Alternate Materials and Methods/Modification Form Importance: High Albert, We have yet another tenant who has been advised that the bathrooms are not compliant and a TI will trigger an upgrade. It was my understanding that the approved AMM addressed your concerns. We have provided all of the requested information, paid the fees and were under the impression this was resolved. Can you please clarify your . position on this. Thx M From: Lopez, Marni Sent:Tuesday, September 08, 2015 1:42 PM To: 'Albert Salvador' Cc: 'kimblackseth@mac.com' Subject: RE: Alternate Materials and Methods/ Modification Form Albert Just following up on this... did you want modified applications set up for each permit#? Happy to prepare these and get them over to your office. Thx M From: Lopez, Marni Sent: Thursday, September 03, 2015 4:41 PM To: 'Albert Salvador' Cc: kimblackseth@mac.com Subject: RE: Alternate Materials and Methods/ Modification Form We had attached a list in the mailing, it must have been omitted from the email string. Apologies. I would ask that it apply to all so that we can put this one to bed. Would you like an application filled out for each permit? If so, I can prepare these and drop them by next week. Thanks for the quick reply M 1 From: Albert Salvador [mailto:AlbertS@cupertino.org] Sent:Thursday, September 03, 2015 4:05 PM To: Lopez, Marni Cc: kimblackseth@mac.com Subject: RE: Alternate Materials and Methods/ Modification Form Good point. Since there were no reference building permit numbers included in your original application, I pulled the latest one we worked on. If this request applies to all eight floors, I will include all eight building permit numbers. Please confirm this is the case and I'll make the change. -Albert Albert Salvador, P.E., C.B.O. Building Official City of Cupertino 10300 Torre Ave. Cupertino, CA 95014 (408) 777-3206 office (408) 777-3333 fax From: Lopez, Marni [mailto:MLopez prometheusreg.coml Sent:Thursday, September 03, 2015 3:55 PM To: Albert Salvador Cc: kimblackseth@mac.com Subject: Alternate Materials and Methods/ Modification Form Albert— I just paid the requested fees but note that the form was modified to reference Permit#15020003 (Vulcan Construction for Seagate). Does this AMM apply only to that project as opposed to the permit#'s for the overall restroom renovation project? Sorry to be a pest,this process is new to me,and I would really like to be certain we get this right. Thx M APN- 369.01.028 20400 Stevens Creek Blvd Permit# Applied 1st Floor 13120165 12/19/2013 2nd Floor 13120165 12/19/2013 2 3rd Ffoor 13120159 12/19/2013 4th Floor 13120159 12/19/2013 5th Floor 13080146 8/20/2013 6th Floor 13080146 8/20/2013 7th Floor 12050091 5/8/2013 8th Floor 12050091 5/8/2013 369-01- APN - 027 20450 Stevens Creek Blvd 1st Floor* 13120163 12/19/2013 2nd Floor 13080145 8/20/2013 3rd Floor 13080145 8/20/2013 4th Floor 13120161 12/19/2013 5th Floor 13120161 12/19/2013 6th Floor** 14040091 4/15/2014 7th Floor 13120164 12/19/2013 8th Floor 13120164 12/19/2019 Marni Lopez I Director of Commercial Operations I PROMETHEUS REAL ESTATE GROUP,INC. Est.1965 South Bay Commercial Office 20400 Stevens Creek Blvd., I Suite 130,Cupertino,CA 95014 Phone:408.873.0121 Fax:408.873.0122 prometheusree.com mlopez@prometheusree.com CONFIDENTIALITY NOTICE This message, including attachments, is confidential and/or privileged and is intended only for the recipient(s) named above. If you are not the intended recipient, you may not review, copy, disclose, or distribute the message or the information contained in it. If you have received the message in error,please notify the sender and immediately delete the message. 3 APN- 369.01.028 20400 Stevens Creek Blvd Permit# Applied Issued Finaled Bldg Plumbing Fire Energy T24 1st Floor 13120165 12/19/2013 1/21/2014 5/8/2014 2010 2010 2010 2010 2010 2nd Floor 13120165 12/19/2013 1/21/2014 5/8/2014 2010 2010 2010 2010 2010 3rd Floor 13120159 12/19/2013 12/19/2013 3/12/2014 2010 2010 2010 2010 2010 4th Floor 13120159 12/19/2013 12/19/2013 3/12/2014 2010 2010 2010 2010 2010 5th Floor 13080146 8/20/2013 8/20/2013 1/28/2014 2010 2010 2010 2010 2010 6th Floor 13080146 8/20/2013 8/20/2013 1/28/2014 2010 2010 2010 2010 2010 7th Floor 12050091 5/8/2013 5/23/2012 1/28/2014 2010 2010 2010 2010 2010 8th Floor 12050091 5/8/2013 5/23/2012 1/28/2014 2010 2010 2010 2010 2010 APN - 369-01-027 Stevens Creek Blvd 1st Floor* 13120163 12/19/2013 1/21/2014 11/18/2014 2010 2010 2010 2010 2010 2nd Floor 13080145 8/20/2013 8/20/2013 11/18/2014 2010 2010 2010 2010 2010 3rd Floor 13080145 8/20/2013 8/20/2013 11/18/2014 2010 2010 2010 2010 2010 4th Floor 13120161 12/19/2013 12/19/2013 3/12/2014 2010 2010 2010 2010 2010 5th Floor 13120161 12/19/2013 12/19/2013 3/12/2014 2010 2010 2010 2010 2010 6th Floor** 14040091 4/15/2014 5/19/2014 11/18/2014 2013 2013 2013 2010 2013 7th Floor 13120164 12/19/2013 1/21/2014 4/28/2014 2010 2010 2010 2010 2010 8th Floor 13120164 12/19/2019 1/21/2014 4/28/2014 2010 2010 2010 2010 2010 *1st floor includes showers. Configuration is different that remaining restroom. **-Six floor scope includes elimination of showers and redemsing