CITY OF CUPERTINO BUILDING PERMIT
BUILDING ADDRESS: 10159 S FOOTHILL BLVD
CONTRACTOR: GENMOR PLUMBING
PERMIT NO: 15110133
OWNER'S NAME: NORDEN, ARNOLD F TRUST
2552 SEABOARD AVE
DATE ISSUED: 11/18/2015
OWNER'S PHONE: 4085977105
SAN JOSE, CA 95131
PHONE NO: (408)855-8348
LICENSED CONTRACTOR'S DECLARATION
JOB DESCRIPTION: RESIDENTIAL E] COMMERCIAL
REMODEL MASTER BATH (95 S.F.); HALLWAY BATH (30
/
License Class — — Lic. # �`2? 9
S.F.); HALF BATH AT LAUNDRY ROOM (32 S.F.);
Leh 1 l —"1 �{'
INSTALL 54 (N) RECESSED LIGHTS; INSTALL 4 (N)
Contractor Date —tot S
I hereby affirm that I am licensed under the provisions of Chapter 9
(commencing with Section 7000) of Division 3 of the Business & Professions
Code and that my license is in full force and effect.
I hereby affirm under penalty of perjury one of the following two declarations:
I have and will maintain a certificate of consent to self-insure for Worker's
Compensation, as provided for by Section 3700 of the Labor Code, for the
Sq. Ft Floor Area:
Valuation: $24000
performance of the work for which this permit is issued.
h �d 14111 maintain Worker's Compensation Insurance, as provided for by
Section Labor Code, for the the for this
APN Number: 34214117.00
Occupancy Type:
_A<the performance of work which
permit is issued.
APPLICANT CERTIFICATION
I certify that I have read this application and state that the above information is
PERMIT EXPIRES IF WORK IS NOT STARTED
correct. I agree to comply with all city and county ordinances and state laws relating
WITHIN 180 DAYS OF PERMIT ISSUANCE OR
to building construction, and hereby authorize representatives of this city to enter
upon the above mentioned property for inspection purposes. (We) agree to save
180 YS FR N.
LAST CALLED INSPyy
indemnify and keep harmless the City of Cupertino against liabilities, judgments,
costs, and expenses which may accrue against said City in consequence of the
cOcM
l
JT
granting of this permit. Additionally, the applicant understands and will comply
Issued by: �Date:1
with all non-point source regulations per the Cupertino Municipal Code, Section
9.18. oe
1— 2 a5 i5
RE-ROOFS:
All roofs shall be inspected prior to any roofing material being installed. If a roof is
installed without first obtaining an inspection, I agree to remove all new materials for
inspection.
OWNER-BUILDER DECLARATION
Signature of Applicant: Date:
1 hereby affirm that I am exempt from the Contractor's License Law for one of
the following two reasons:
ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER
I, as owner of the property, or my employees with wages as their sole compensation,
will do the work, and the structure is not intended or offered for sale (Sec.7044,
Business & Professions Code)
I, as owner of the property, am exclusively contracting with licensed contractors to
HAZARDOUS MATERIALS DISCLOSURE
construct the project (Sec:7044, Business & Professions Code).
I have read the hazardous materials requirements under Chapter 6.95 of the
California Health & Safety Code, Sections 25505, 25533, and 25534. I will
I hereby affirm under penalty of perjury one of the following three
maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the
declarations:
Health & Safety Code, Section 25532(a) should I store or handle hazardous
I have and will maintain a Certificate of Consent to self-insure for Worker's
material. Additionally, should I use equipment or devices which emit hazardous
Compensation, as provided for by Section 3700 of the Labor Code, for the
air contaminants as defined by the Bay Area Air Quality Management District I
performance of the work for which this permit is issued.
will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and
I have and will maintain Worker's Compensation Insurance, as provided for by
the Health & • ty Code, Sections 25505, 25533, and 25534.
Section 3700 of the Labor Code, for the performance of the work for which this
- 0
Owner or authorized age Date:
permit is issued:
r•
I certify that in the performance of the work for which this permit is issued, I shall
not employ any person in any manner so as to become subject to the Worker's
Compensation laws of California. If, after making this certificate of exemption, I
CONSTRUCTION LENDING AGENCY
become subject to the Worker's Compensation provisions of the Labor Code, I must
I hereby affirm that there is a construction lending agency for the performance of
forthwith comply with such provisions or this permit shall be deemed revoked.
work's for which this permit is issued (Sec. 3097, Civ C.)
Lender's Name
APPLICANT CERTIFICATION
Lender's Address
I certify that I have read this application and state that the above information is
correct. I agree to comply with all city and county ordinances and state laws relating
to building construction, and hereby authorize representatives of this city to enter
upon the above mentioned property for inspection purposes. (We) agree to save
indemnify and keep harmless the City of Cupertino against liabilities, judgments,
ARCHITECT'S DECLARATION
costs, and expenses which may accrue against said City in consequence of the
I understand my plans shall be used as public records.
granting of this permit. Additionally, the applicant understands and will comply
with all non-point source regulations per the Cupertino Municipal Code, Section
'Licensed Professional
9.18.
Signature Date
CUPERTINO
❑ NEW CONSTRUCTION
CONSTRUCTION PERMIT APPLICATION
COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION
10300 TORRE AVENUE • CUPERTINO, CA 95014-3255
(408) 777-3228 • FAX;�AL8 77-3333 • building(a)-cupertino.org
ADDITION TERATION/Tl ❑ REVISION /DEFERRED ORIGINAL PERMIT #
PROJECT ADDRESS IDI
F77--
OWNERNAMEi�Qn�(�' o PHONE _ E -MA L
No ►� - Fd �F `6V �/ 'RUST
IR''r
`R�
STREET ADDRESS g CITY, STATE, ZIE FAX
of S L
CONTACT NAME p�'o, SCA I, Q PHONE MAIL a
STREET ADDRESS 10ASe f2 `� I CITY, STATE, ZIPno C FAX
i
OWNER ❑ OWNER -BUILDER ❑ OWNERAGENT ❑ CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT
CONTRACTOR NAME
Ci 6
LICENSE NUMBER^
LICENSE TYPE
C R2
BUS. LIC #
COMPANY NAME
E-MAIL coAhOD I I '
ap
FAX '
129
STREET ADDRESS
C Y, STATE rQ Ct I
PHONE
ARCHITECT/ENGINEER NAME
LICENSE NUMBER
BUS. LIC #
COMPANY NAME
E-MAIL
FAX
STREET ADDRESS
CITY, STATE, ZIP
PHONE
ZZ 9Q se
DESCRIPTION OF WORK
16 b06 r��onfi r� cqb
(L55
EXISTING USE
PROPOSED USE CONSTR.
TYPE
# 0RrES
USE
TYPE
OCC.
SQ.FT.
VALUATION ($)
EXISTG
NEW FLOOR
DEMO
TOTAL
..
AREA
AREA
AREA
NET AREA
BATHROOM
KITCHEN
OTHER
REMODEL AREA
REMODEL AREA
ODEL AREA
PORCH AREA
DECK AREA
TOTAL DEC RCH AREA
GARAGE AREA: EIDETACH
ATTACH
# DWELLING UNITS:
ISA SECOND UNrr ❑ YES
SECOND STORY ❑ YES
BEING ADDED? ❑ NO
ADDITION? [-]NO
PRE -APPLICATION ❑ YES IF YES, PROVIDE COPY OF
PLANNING APPL # ❑ NO PLANNING APPROVAL LETTER
IS THE BLDG AN ❑ YES
EICHLER HOME? ❑ NO
GE ED BY t
[
TOTAL VALUATION:
,
By my signature below, I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. I have read this
application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local
ordinances and state laws relating to building construction. I authorize representatives of Cupertino to enter the above -identified property for inspection purposes.
Signature of Applicant/Agent: Date:
SUPPLEMENTAL INFORMATION REQUIRED
PL"AivcliEccYri
r Ro'rrrnvSLIP {`
- New SFD or Multifamily dwellings: Apply for demolition permit for
3
OVER THE COUNTE[L
❑ BUII DING PLANREVIEw"
existing building(s). Demolition permit is required prior to issuance of building
- _-
permit for new building.
❑'EXPRESS o
C1 PLANNING PLAN REVIEW
Commercial Bldgs: Provide a completed Hazardous Materials Disclosure
❑ STANDARD
a
PUBLIC woRKS
form if any Hazardous Materials are being used as part of this project.
❑
LARGEAQ&ZFIRE
DEPT
_ Copy of Planning Approval Letter or Meeting with Planning prior to
= `
❑
submittal of Building Permit application.
MAJOR"
SANITARY SEWER DISTRICT
/ ry i , r.:: ,
.❑�EIVVIRUNMENTAL'IiEAI:TH"
BldgApp_2011.doc revised 06/21/11
COA
0.60
I
62
CITY OF CUPERTINO 115�10 133
FEE ESTIMATOR -BUILDING DIVISION
vkch. 111an ("heck I' run,,b. I' an ("heck: Elec. Plan Check 10.0 1 hrs $0.00
7 y :t:If>c:�#..r"'�i•;ri, .t <»:I'1ui#ib. Permit I�*r>Y•. Elec. Permit Fee: IEPERMIT
clah�r: <iPtyL h..C;rsir. -011ier llhurib fnsp. Other Elec. Insp. 0.0 hrs $48.00
31ec'Ir. 1r<sx7. It�r'' t" t#rrif3..Ir#:��2. ;`>e: f,tc°c. tga:3t;. I ee:
NOTE. This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School
uistrict, etc.). [ nese_rees are oasea on the preummary information avauaate ana are only an esumate. contact the ueptjor aaan •t info.
FEE ITEMS (Fee Resolution 11-053 Eff. 7/1/131
ADDRESS: 10159 S Foothill Blvd
[DATE: 11/18/2015
REVIEWED BY: PAUL
APN: 34214117
BP#:
'EVALUATION: 1$24,000
*PERMIT TYPE: Building Permit
PLAN CHECK TYPE: Addition
PRIMARY SFD or Duplex
USE:
0.0
PENTAMATION 1 R3SFDREM
PERMIT TYPE:
WORK
Remodel Master Bath 95 S.f. ; Hallway Bath 30 S.f. ; Half.Bath at Laundry Room 32 S.f. • Install 54
SCOPE
(N) recessed lights; .Install 4 (N) ceiling fan's
vkch. 111an ("heck I' run,,b. I' an ("heck: Elec. Plan Check 10.0 1 hrs $0.00
7 y :t:If>c:�#..r"'�i•;ri, .t <»:I'1ui#ib. Permit I�*r>Y•. Elec. Permit Fee: IEPERMIT
clah�r: <iPtyL h..C;rsir. -011ier llhurib fnsp. Other Elec. Insp. 0.0 hrs $48.00
31ec'Ir. 1r<sx7. It�r'' t" t#rrif3..Ir#:��2. ;`>e: f,tc°c. tga:3t;. I ee:
NOTE. This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School
uistrict, etc.). [ nese_rees are oasea on the preummary information avauaate ana are only an esumate. contact the ueptjor aaan •t info.
FEE ITEMS (Fee Resolution 11-053 Eff. 7/1/131
FEE
QTY/FEE
MISC ITEMS
Plan Check Fee:
$0.00
=s.f.
$645.00
Remodel, Bath (<=300 sf)
IREMRESBAT
Suppl. PC Fee: Reg. 0 OT
0.0
hrs
$0.00
PME Plan Check:
$0.00[--2-2-70s.f.
$645.00
Remodel, Kitchen (<=300 sf)
IREMRESKIT
Permit Fee:
$0.00
Suppl. Insp. Fee: Reg. 0 OT
0.0
hrs
$0.00
58 Electrical
$300.00 1BREMFmT Fixtures, Lighting
PME Unit Fee:
$0.00
PME Permit Fee:
$48.00
consiruCtion Rzx:
F71
Administrative Fee: IADMIN
$45.00
Q
Work Without Permit? 0 Yes (F) No
$0.00
Advanced Planning Fee:
$0.00
Select a Non -Residential
Building or Structure
G
0
i
Travel Documentation Fee: ITRAVDOC
$48.00
Strong Motion Fee: 1BSEISMICR
$3.12
Select an Administrative Item
Bldg Stds Commission Fee: IBCBSC
$1.0
SUBTOTALS
145.12
$1, 590.00
TQTAL FEE
Revised: 10/01/2015
1h
OFFICE COPY
W
1 EXISTING FLOOR PLAN
1 /4" = V O' 5 N
E
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING DIVISION - CUPERTINO
APPROVED
This set of plans and specifications MUST be kept at the
Job site during construction. It is unlawful to make any
changes or alterations on same, or to deviate
therefrom, without approval from the Building Official.
The stamping of this plan and specifications SHALL NOT
be held to permit or to be an approval of the violation
of a ' provisions of any City Ordinance or State Law.
BY [�
DATE
PERMIT N .
CUPERTINO
Building Department
NOV 18 2015
REVIEWED FOR CODE COMPLI
Reviewed By: T uwt"�w
NOV 15' 2015
B
LEGEND AND NOTES:
1. THESE DRAWINGS ARE BASED UPON AVAILABLE
DOCUMENTS, WHICH MAY NOT ACCURATELY PORTRAY
AS-BUILTCONDRIONS. EXISTING EQUIPMENT SIZES,
LOCATIONS, AND DIMENSIONS SHALL BE VERIFIED IN THE
FIELD PRIOR TO DEMOLITION AND CONSTRUCTION
NOTIFY THE OWNER IMMEDIATELY OF ALL
DISCREPANCIES AFFECTING THE REMOVAL OF EXISTING
EQUIPMENT AND THE INSTALLATION OF NEW EQUIPMENT.
ALL FIXTURES AND BUILDING COMPONENTS ARE EXISTING
UNLESS NOTED OTHERWISE.
CONTRACTOR
GENMOR PLUMBING INC.
CONTRACTOR LIC.
833961 C-36 & B
254B SEABOARD AVE.
SAN JOSE, CA 951 31
— 4013-B55-8348
ISSUANCE AND REVISIONS
REV. DATE DESCRIPTION
11.28.15 PERMITSET
PROJECT:
TANEJA RESIDENCE
1 0 59 S. FOOTHILL BLVD.,
CUPERTINO, CA 95014
DRAWN
SCALE AS NOTED
DATE 11.18.15
JOB ND. 21818
FILE
TITLE:
EXISTING FLOOR PLAN
A2.1
SHEET NO.
JWO
CLOSET
CLOSET
MASTER BATH
a 8S SO. FT. o
-o
BATH II ul
30 SO. FT. hull 7
N o
BED HAL
166 SO. FT. 76SO.
0
CLOSET II CLOSET
o a
LIVING
a 238 SO. FT. o
o a
9
QA..
MASTER BED
204 SO. FT.
(N) CEILING FAN, NP. OF (4)
(N) 6' DIA HIGH EFFICACY
n LED RECESSED LIGHT. NP.
1.1
BED
138 SO. FT.
o a�
DINING
726 S0. FT.
a a
O � �
5m�
a o
(N) SWITCHES AND DIMMERS,
TVP.
BUILDING NOTES:
1. BEDROOM SHALL HAVE HARDWIRED, INTERCONNECTED SMOKE AND CARBON
MONOXIDE ALARMS W/BATTERY BACKUP:
-SMOKE ALARMS INSIDE NEW BEDROOMS AND IMMEDIATELY OUTSIDE
THE SLEEPING AREA
-CARBON MONOXIDE ALARMS IMMEDIATELY OUTSIDE THE NEW,
SLEEPING AREA
2. USE ONLY APPROVED TILE BACKER MATERIALS AND GYP BOARD IN
BATHROOMS:
-CEMENT, FIBER -CEMENT OR GLASS -MAT GYP BACKERS FOR ADHESIVE
APPUCATION OF FINISH MATERIALS (TILE OR OTHER NONABSORBENT
SHEET MATERIALS), OR PAINT (ABOVE 721. INSTALLED PER
MANUFACTURER'S INSTRUCTIONS WITHIN SHOWER STALLS AND
BATHTUB SURROUNDS.
- WATER-RESISTANT GYP BOARD SHALL NOT BE USED WITHIN SHOWER
STALLS, BATHTUB COMPARTMENTS OR OTHER WET OR HUMID AREAS,
OR CN CEILINGS WITH JOISTS GREATER THAN 12' ON CENTER.
- WATER-RESISTANT GYP BACKERS FOR TLE OR PAINT PER
MANUFACTURER'S INSTRUCTIONS AT WATER CLOSET COMPARTMENTS.
- REGULAR GYP BOARD FOR TILE OR PAINT ON WALLS AND CEILINGS
OTHER TITAN ABOVE
ENERGY NOTES -
1. BATHROOM FANS USEDAS IAQ VENTILATION SHALL BE MINIMUM 60CFMTHE
MINIMUM VENTILATION RATE ISI CFM PER EACH 100 SQUARE FEETOF FLOOR
AREA PLUS 7.6 CFM PER EACH BEDROOM. BATHROOM FANS USED AS IAO
VENTILATION SHALL BE RATED FOR CONTINUOUS OPERATION WITH A
MANUAL OVERRIDE SWITCH. BATHROOM FANS USED AS IAQ VENTILATION
SHALL HAVE MAXIMUM SOUND RATING OF 1 SONE.
2. SEE SHEET T24 FOR ADDITIONAL ENERGY NOTES AND MANDATORY
MEASURES.
C
GARAGE
526 SQ. FT.
as LAUNDRY
28 SO. FT. HALF BATH
32 SO. FT.
o a
W
PROPOSED REFLECTED CEILING PLAN
1/4" =1'-0" s N
E
2'-0'
(N) PANTRY
ELECTRICAL NOTES:
1. LABEL ALL BREAKERS. ALL CONDUCTORS SHALL BE COPPER.
ALL MULTI -WIRE CIRCUITS SHALL HAVE A MEANS OF SIMULTANEOUSLY
DISCONNECTING ALL UNGROUNDED CONDUCTORS AT THE BREAKER PANEL
ALL CONDUCTORS FOR MULTI -WIRE CIRCUITS SHALL BE GROUPED WITH
WIRE TIES WITHIN THE BREAKER PANEL ALL NEW 15 AND 20 AMP CIRCUITS
SHALL BE PROTECTED WITH AN ARC FAULT CIRCUIT INTERRUPTER (AFCI),
EXCEPT KITCHENS,BATHROOMS, LAUNDRY ROOMS, GARAGES AND
BASEMENT AREAS. ALL NEW RECEPTACLES INSTALLED SHALL BE
TAMPER-RESISTANT.
2. ALL NEW HARD -WIRED SMOKE AND CARBON MONOXIDE ALARMS SHALL BE
PROTECTED WITH AN ARC FAULT CIRCUIT INTERRUPTER (AFCI).
3. PROVIDE A 20 AMP DEDICATED CIRCUIT FOR NEW BATHROOM
PROVIDE A GFCI PROTECTED, TAMPER RESISTANT RECEPTACLE WITHIN 3' OF
THE BATHROOM LAVATORY, OR ON THE SIDE OF THE VANITY CABINET WITHIN
12 INCHES OF THE TOP.
4. PROVIDE TAMPER-RESISTANT WALL RECEPTACLES IN HABITABLE ROOMS
MAXIMUM IT ON CENTER, AND MAXIMUM 6' FROM ANY OPENING 6 AT WALLS
LONGER THAN 2'. PROVIDE A TAMPER-RESISTANT RECEPTACLE IN NEW
HALLWAY LONGER THAN 10 FEET. PROVIDE GFCI PROTECTED
TAMPER-RESISTANT RECEPTACLES WITHIN 6' OF NEW WET BAR OR LAUNDRY
SINK PROVIDE GFCI PROTECTION FOR NEW TAMPER-RESISTANT
RECEPTACLES LOCATED IN THE GARAGE, BASEMENT, CRAWL SPACE OR
OTHER DAMP AREA
PLUMBING NOTES:
1. PLASTIC PIPING SHALL NOT BE USED FOR DRAIN, VENT, GAS OR DOMESTIC
WATER SUPPLY. PROVIDE BACKFLOW PREVENTION DEVICE ON HOSE BIBBS.
PROVIDE DIELECTRIC UNIONS AT CONNECTIONS BETWEEN DISSIMILAR
METALS.
2. SHOWER HEADS SHALL BE MAXIMUM 2.0 GALLONS PER MINUTE. LAVATORY
FAUCETS SHALL BE MAXIMUM 1.5 GALLONS PER MINUTE. WATER CLOSETS
SHALL BE MAXIMUM 1.28 GALLONS PER FLUSH.
3. PROVIDE 30' MINIMUM CLEAR WIDTH FOR THE WATER CLOSET. PROVIDE 15'
MINIMUM CLEAR SIDE CLEARANCE FROM THE CENTER OF WATER CLOSET.
PROVIDE 24' MINIMUM CLEAR IN FRONT OF THE WATER CLOSET.
4. BATHTUB FILLERS SHALL BE UMITEO TO 120 DEGREES F BYA DEVICE THAT
CONFORMS TOASSE 1070. SHOWER VALVES SHALL BEA PRESSURE!
TEMPERATURE BALANCED TYPE THAT CONFORMS TO ASSE 1016.
LOCATE THE SHOWERHEAD ON THE SIDE WALL OF THE SHOWER
COMPARTMENT. SHOWERS SHALL BE FINISHED WITH A NONABSORBENT
FINISH TO A HEIGHT OF AT LEAST 72'ABOVE FLOOR SHOWERS SHALL BE AT
LEAST 32'X 32' OR 1024 SQUARE INCHES WITH NOT LESS THAN 30' WIDTH.
S. NEW DISHWASHER SHALL USE LESS THAN 6.5 GALLON PER CYCLE, OR BE
ENERGY STAR QUALIFIED.
20'-2'
10'-2'
5'-2' 3'-0'
ELECTRICAL SYMBOL LEGEND
a
a
O
a
®
LIGHT- HIGH EFFICACY CEILING MOUNTED
KITCHEN
LIGHT- HIGH EFFICACY LED RECESSED
e
gr
LIGHT- HIGH EFFICACY LED WALL MOUNT
220 SO. FT.
IDISH WASHER
1
RECEPTACLE OUTLET - GFCI &TEMPER -RESISTANCE
o
a
a
a T,E
DINING
726 S0. FT.
a a
O � �
5m�
a o
(N) SWITCHES AND DIMMERS,
TVP.
BUILDING NOTES:
1. BEDROOM SHALL HAVE HARDWIRED, INTERCONNECTED SMOKE AND CARBON
MONOXIDE ALARMS W/BATTERY BACKUP:
-SMOKE ALARMS INSIDE NEW BEDROOMS AND IMMEDIATELY OUTSIDE
THE SLEEPING AREA
-CARBON MONOXIDE ALARMS IMMEDIATELY OUTSIDE THE NEW,
SLEEPING AREA
2. USE ONLY APPROVED TILE BACKER MATERIALS AND GYP BOARD IN
BATHROOMS:
-CEMENT, FIBER -CEMENT OR GLASS -MAT GYP BACKERS FOR ADHESIVE
APPUCATION OF FINISH MATERIALS (TILE OR OTHER NONABSORBENT
SHEET MATERIALS), OR PAINT (ABOVE 721. INSTALLED PER
MANUFACTURER'S INSTRUCTIONS WITHIN SHOWER STALLS AND
BATHTUB SURROUNDS.
- WATER-RESISTANT GYP BOARD SHALL NOT BE USED WITHIN SHOWER
STALLS, BATHTUB COMPARTMENTS OR OTHER WET OR HUMID AREAS,
OR CN CEILINGS WITH JOISTS GREATER THAN 12' ON CENTER.
- WATER-RESISTANT GYP BACKERS FOR TLE OR PAINT PER
MANUFACTURER'S INSTRUCTIONS AT WATER CLOSET COMPARTMENTS.
- REGULAR GYP BOARD FOR TILE OR PAINT ON WALLS AND CEILINGS
OTHER TITAN ABOVE
ENERGY NOTES -
1. BATHROOM FANS USEDAS IAQ VENTILATION SHALL BE MINIMUM 60CFMTHE
MINIMUM VENTILATION RATE ISI CFM PER EACH 100 SQUARE FEETOF FLOOR
AREA PLUS 7.6 CFM PER EACH BEDROOM. BATHROOM FANS USED AS IAO
VENTILATION SHALL BE RATED FOR CONTINUOUS OPERATION WITH A
MANUAL OVERRIDE SWITCH. BATHROOM FANS USED AS IAQ VENTILATION
SHALL HAVE MAXIMUM SOUND RATING OF 1 SONE.
2. SEE SHEET T24 FOR ADDITIONAL ENERGY NOTES AND MANDATORY
MEASURES.
C
GARAGE
526 SQ. FT.
as LAUNDRY
28 SO. FT. HALF BATH
32 SO. FT.
o a
W
PROPOSED REFLECTED CEILING PLAN
1/4" =1'-0" s N
E
2'-0'
(N) PANTRY
ELECTRICAL NOTES:
1. LABEL ALL BREAKERS. ALL CONDUCTORS SHALL BE COPPER.
ALL MULTI -WIRE CIRCUITS SHALL HAVE A MEANS OF SIMULTANEOUSLY
DISCONNECTING ALL UNGROUNDED CONDUCTORS AT THE BREAKER PANEL
ALL CONDUCTORS FOR MULTI -WIRE CIRCUITS SHALL BE GROUPED WITH
WIRE TIES WITHIN THE BREAKER PANEL ALL NEW 15 AND 20 AMP CIRCUITS
SHALL BE PROTECTED WITH AN ARC FAULT CIRCUIT INTERRUPTER (AFCI),
EXCEPT KITCHENS,BATHROOMS, LAUNDRY ROOMS, GARAGES AND
BASEMENT AREAS. ALL NEW RECEPTACLES INSTALLED SHALL BE
TAMPER-RESISTANT.
2. ALL NEW HARD -WIRED SMOKE AND CARBON MONOXIDE ALARMS SHALL BE
PROTECTED WITH AN ARC FAULT CIRCUIT INTERRUPTER (AFCI).
3. PROVIDE A 20 AMP DEDICATED CIRCUIT FOR NEW BATHROOM
PROVIDE A GFCI PROTECTED, TAMPER RESISTANT RECEPTACLE WITHIN 3' OF
THE BATHROOM LAVATORY, OR ON THE SIDE OF THE VANITY CABINET WITHIN
12 INCHES OF THE TOP.
4. PROVIDE TAMPER-RESISTANT WALL RECEPTACLES IN HABITABLE ROOMS
MAXIMUM IT ON CENTER, AND MAXIMUM 6' FROM ANY OPENING 6 AT WALLS
LONGER THAN 2'. PROVIDE A TAMPER-RESISTANT RECEPTACLE IN NEW
HALLWAY LONGER THAN 10 FEET. PROVIDE GFCI PROTECTED
TAMPER-RESISTANT RECEPTACLES WITHIN 6' OF NEW WET BAR OR LAUNDRY
SINK PROVIDE GFCI PROTECTION FOR NEW TAMPER-RESISTANT
RECEPTACLES LOCATED IN THE GARAGE, BASEMENT, CRAWL SPACE OR
OTHER DAMP AREA
PLUMBING NOTES:
1. PLASTIC PIPING SHALL NOT BE USED FOR DRAIN, VENT, GAS OR DOMESTIC
WATER SUPPLY. PROVIDE BACKFLOW PREVENTION DEVICE ON HOSE BIBBS.
PROVIDE DIELECTRIC UNIONS AT CONNECTIONS BETWEEN DISSIMILAR
METALS.
2. SHOWER HEADS SHALL BE MAXIMUM 2.0 GALLONS PER MINUTE. LAVATORY
FAUCETS SHALL BE MAXIMUM 1.5 GALLONS PER MINUTE. WATER CLOSETS
SHALL BE MAXIMUM 1.28 GALLONS PER FLUSH.
3. PROVIDE 30' MINIMUM CLEAR WIDTH FOR THE WATER CLOSET. PROVIDE 15'
MINIMUM CLEAR SIDE CLEARANCE FROM THE CENTER OF WATER CLOSET.
PROVIDE 24' MINIMUM CLEAR IN FRONT OF THE WATER CLOSET.
4. BATHTUB FILLERS SHALL BE UMITEO TO 120 DEGREES F BYA DEVICE THAT
CONFORMS TOASSE 1070. SHOWER VALVES SHALL BEA PRESSURE!
TEMPERATURE BALANCED TYPE THAT CONFORMS TO ASSE 1016.
LOCATE THE SHOWERHEAD ON THE SIDE WALL OF THE SHOWER
COMPARTMENT. SHOWERS SHALL BE FINISHED WITH A NONABSORBENT
FINISH TO A HEIGHT OF AT LEAST 72'ABOVE FLOOR SHOWERS SHALL BE AT
LEAST 32'X 32' OR 1024 SQUARE INCHES WITH NOT LESS THAN 30' WIDTH.
S. NEW DISHWASHER SHALL USE LESS THAN 6.5 GALLON PER CYCLE, OR BE
ENERGY STAR QUALIFIED.
20'-2'
10'-2'
5'-2' 3'-0'
ELECTRICAL SYMBOL LEGEND
c_Lfy'JCl
�e
CEILING FAN- CEILING MOUNTED FAN
EXHAUST FAN- HUMIDITY SENSOR CEILING MOUNTED FAN
®
LIGHT- HIGH EFFICACY CEILING MOUNTED
LIGHT- HIGH EFFICACY LED RECESSED
LIGHT- HIGH EFFICACY LED WALL MOUNT
RECEPTACLE OUTLET -TEMPER -RESISTANCE
IDISH WASHER
1
RECEPTACLE OUTLET - GFCI &TEMPER -RESISTANCE
SWITCH - DIMMER
Scow
SWITCH -3 -WAY
S-
SWITCH -VACANCY SENSOR
S...
SWITCH -OCCUPANCY SENSOR
SMOKE ALARM COMBINATION
(N) GRANITE COUNTER TOP, TYP.
-
Vco°K'
SMOKE& CARBON DIOXIDE ALARM COMBINATION
10'-0'
CUPERTINO
Building Department
NOV 18 2015
REVIEWED FOR CODE COMPLI)
Reviewed By: Tfxiv�m�w
0 0
---- -
� �6FD1 I I �IDrD1 I i �DF 1
418'-4'
V.I.F. 1'-6' 1, 1'-0' 2`0'
t10'-2'
W
ENLARGED KITHCEN LAYOUT PLAN
E
LEGEND AND NOTES:
1. THESE DRAWINGS ARE BASED UPON AVAILABLE
DOCUMENTS, WHICH MAY NOT ACCURATELY PORTRAY
AS-BUILTCONDITIONS. EXISTING EQUIPMENT SIZES,
LOCATIONS, AND DIMENSIONS SHALL BE VERIFIED IN THE
FIELD PRIOR TO DEMOLITION AND CONSTRUCTION.
NOTIFY THE OWNER IMMEDIATELY OF ALL
DISCREPANCIES AFFECTING THE REMOVAL OF EXISTING
EQUIPMENT AND THE INSTALLATION OF NEW EQUIPMENT.
ALL FIXTURES AND BUILDING COMPONENTS ARE EXISTING
UNLESS NOTED OTHERWISE
2. INSTALL EQUIPMENT TO BEST SUIT FIELD CONDITIONS
AND COORDINATE WITH THE INSTALLATION WORK OF
OTHERTRADES. THESE DRAWINGS ARE DIAGRAMMATIC,
DO NOT SCALE TO DETERMINE EXACT LOCATION OF
DEVICES.
3. PROTECT ALL EXISTING EQUIPMENT THAT IS TO
REMAIN. VERIFY WITH OWNER WHICH SYSTEMS MUST
REMAIN OPERATIONAL THROUGHOUT CONSTRUCTION.
NOTIFY THE OWNER PRIOR TO SHUTTING DOWN
EQUIPMENT.
4. REPAIR AND/OR REPLACE ALL EXISTING UTILITIES,
STRUCTURAL ELEMENTS, EQUIPMENT, PIPING, CONDUIT,
DUCTWORK, FINISHES, ETC. THAT ARE DAMAGED OR
BECOME INOPERABLE AS A RESULT OF THIS WORK
5. COORDINATE MODIFICATIONS TO EXISTING ELECTRICAL
AND MECHANICAL SYSTEMS WITH OWNER TO MINIMIZE
SHUTDOWN TIME OF BUILDING SYSTEMS.
6. FOR ALL ELECTRICAL SYSTEMS CONTROLS, PROVIDE
CONDUIT AND WIRING IN ACCORDANCE WITH ELECTRICAL
SPECIFICATIONS AND MANUFACTURER'S REQUIREMENTS
CONTRACTOR
NCE
GENM❑R PLUMBING INC.
CONTRACTOR LIC.
833961 0-36 & B
254B SEABOARD AVE.
SAN JOSE, CA 95131
408-B55-B34B
ISSUANCE AND REVISIONS :
REV. DATE DESCRIPTION
11.28.15 PERMITSET
PROJECT:
TANEJA RESIDENCE
1 0 59 S. FOOTHILL BLVD.,
CUPERTIN❑, CA 951114
DRAWN
SCALE AS NOTED
DATE 11.18.15
JOB NO. 21818
FILE
TITLE:
PROPOSED FLOOR PLANS
SHEET NO.
GFb1
1 D I
DIS
J'
—
REFRIGERATOR
IDISH WASHER
1
I �
I o
4
I�
(N) GRANITE COUNTER TOP, TYP.
-
(N) UPPER CABINET, TYR
4
(N) 20 -AMP GFCI, TAMPER- RESISTANT
v
RECEPTACLE OUTLET, TYP. CONTRACTOR
SHALL INSTALL A MIN. OF TWO 20 -AMP
BRANCH CIRCUITS FOR SMALL KITCHEN
+1
KITCHEN
APPLIANCES
220 SO. FT.
0 0
---- -
� �6FD1 I I �IDrD1 I i �DF 1
418'-4'
V.I.F. 1'-6' 1, 1'-0' 2`0'
t10'-2'
W
ENLARGED KITHCEN LAYOUT PLAN
E
LEGEND AND NOTES:
1. THESE DRAWINGS ARE BASED UPON AVAILABLE
DOCUMENTS, WHICH MAY NOT ACCURATELY PORTRAY
AS-BUILTCONDITIONS. EXISTING EQUIPMENT SIZES,
LOCATIONS, AND DIMENSIONS SHALL BE VERIFIED IN THE
FIELD PRIOR TO DEMOLITION AND CONSTRUCTION.
NOTIFY THE OWNER IMMEDIATELY OF ALL
DISCREPANCIES AFFECTING THE REMOVAL OF EXISTING
EQUIPMENT AND THE INSTALLATION OF NEW EQUIPMENT.
ALL FIXTURES AND BUILDING COMPONENTS ARE EXISTING
UNLESS NOTED OTHERWISE
2. INSTALL EQUIPMENT TO BEST SUIT FIELD CONDITIONS
AND COORDINATE WITH THE INSTALLATION WORK OF
OTHERTRADES. THESE DRAWINGS ARE DIAGRAMMATIC,
DO NOT SCALE TO DETERMINE EXACT LOCATION OF
DEVICES.
3. PROTECT ALL EXISTING EQUIPMENT THAT IS TO
REMAIN. VERIFY WITH OWNER WHICH SYSTEMS MUST
REMAIN OPERATIONAL THROUGHOUT CONSTRUCTION.
NOTIFY THE OWNER PRIOR TO SHUTTING DOWN
EQUIPMENT.
4. REPAIR AND/OR REPLACE ALL EXISTING UTILITIES,
STRUCTURAL ELEMENTS, EQUIPMENT, PIPING, CONDUIT,
DUCTWORK, FINISHES, ETC. THAT ARE DAMAGED OR
BECOME INOPERABLE AS A RESULT OF THIS WORK
5. COORDINATE MODIFICATIONS TO EXISTING ELECTRICAL
AND MECHANICAL SYSTEMS WITH OWNER TO MINIMIZE
SHUTDOWN TIME OF BUILDING SYSTEMS.
6. FOR ALL ELECTRICAL SYSTEMS CONTROLS, PROVIDE
CONDUIT AND WIRING IN ACCORDANCE WITH ELECTRICAL
SPECIFICATIONS AND MANUFACTURER'S REQUIREMENTS
CONTRACTOR
NCE
GENM❑R PLUMBING INC.
CONTRACTOR LIC.
833961 0-36 & B
254B SEABOARD AVE.
SAN JOSE, CA 95131
408-B55-B34B
ISSUANCE AND REVISIONS :
REV. DATE DESCRIPTION
11.28.15 PERMITSET
PROJECT:
TANEJA RESIDENCE
1 0 59 S. FOOTHILL BLVD.,
CUPERTIN❑, CA 951114
DRAWN
SCALE AS NOTED
DATE 11.18.15
JOB NO. 21818
FILE
TITLE:
PROPOSED FLOOR PLANS
SHEET NO.