Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
15120004
CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 10374 S TANTAU AVE CONTRACTOR: SEARS HOME PERMIT NO: 15120004 IMPROVEMENT OWNER'S NAME: FORBRICH FALKO TRUSTEE & ET AL 1024 FLORIDA CENTRAL PKWY DATE ISSUED: 12/01/2015 OWNER'S PHONE: 8185858403 LONGWOOD, FL 32750 PHONE NO: (925)245-2000 011-1 LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL E] COMMERCIAL 0 q �2' 3! INSTALL (N) SIDING ON FRONT AND RIGHT SIDE License Class Lie. # / EXTERIOR (290 S.F.) Contractor 7 !'I 0,,,Af , M a. Date 2 I s I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the Sq. Ft Floor Area: Valuation: $3901 performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this APN Number: 37508032.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITIIIN 180 DAYS OF PERMIT ISSUANCE OR to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save 180 DAYS FROM LAST CALLED INSPEC I N. indemnify and keep harmless the City of Cupertino against liabilities, judgments, , costs, and expenses which may accrue against said City in consequence of the Qao�w7l-comply Issued by: Al Date: granting of this permit. Additionally, the applicant understands and w with all non -point source regulations per the Cupertino Munic' ai ode, Section 9.18. RE -ROOFS: Signature Date i Z(� I All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. _�� El OWN -&i�ILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) I, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (See.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(a) should I store or handle hazardous I have and will maintain a Certificate of Consent to self -insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code, Chapter A -2 -and I have and will maintain Worker's Compensation Insurance, as provided for by the Health & Safety Code.Sections 25505, 25533, and 25534. Section 3700 of the Labor Code, for the performance of the work for which this S permit is issued. Owner or authorized agent: Date: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code, I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section Licensed Professional 9.18. Signature Date CONSTRUCTION PERMIT APPLICATION )5 [aTOL� COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 CIJPER l C� (408) 777-3228 • FAX (408) 777-3333 • building cDcupertino.org ❑ NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION /T1 ❑ REVISION / DEFERRED ORIGINAL PERMIT # 0 CT ADDR SS I (^ I ,40 APN # ®v ( '�a OWNER NAME> B ' P ONE r 5 t -I0 3 E-MAIL S7'©- ADDRESS - _T� (AU ,AVL CITY, STCIOATE. 0 A 9 /0 FAX CONTACT NAME Christine Mohwinkel PHONE 916-81330-3400 E --MAIL STREET ADDRESS 1200 DEL PASO RD, Unit 100 CITY, STATE, ZIP SACRAMENTO,CA 95834 FAX ❑ OWNER ❑ OWNER -BUILDER ❑ OWNER AGENT 'LI CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME LICENSE NUMBER 721379 LICENSE TYPE BUS. LIC # B C6 C20 C39 C10 '9MA''9'48ME IMPROVEMENT PRODUCTS E-MAIL FAX 407-551-3085 STREET ADDRESS 1200 DEL PASO RD, Unit 100 CITY, STATE, ZIP SACRAMENTO,CA 95834 PHONE 916-830-3400 ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS. LIC # CONIPANY NAME E-MAIL FAX S"rREET ADDRESS CITY, STATE, ZiP PHONE DESCRIPTION OF WORK )J �� n_ I / I 1 7,9 v 2�o EXISTING USE JJ / PROPOSED USE CONSTR. TYPE # STORIES OFFICE USE ONLY OCC. TYPE DESCRIPTION S .FT. VALUATION S I ICI �1wY I ' � M is -� �= EXISTG NEW FLOOR DEMO TNET TOTAL AREA AREA AREA AREA BATHROOM KITCHEN OTHER RENIODELAREA REMODEL AREA REMODELAREA ' PORCH AREA DECK AREA TOTAL DECK/PORCH AREA GARAGE AREA: ❑ DETACH ❑ ATTACH 'I)\1'I:I.I_IN(iI NIT'S. IS ASECOND UNIT Y1:S SECOND STORY ❑ylss BEINGADD ED'.' ❑ NO ADDITION! ❑ NO PRI:-APPIVAI ION ❑ Yrs Ir•Yr.s,PROMECOPYor• PI,ANTPR'5NA.1. RECEIVEDj fAUL OTALVALUATION: �3 H A\_NIN(i APPI, P ❑ NO PI.ANTINO APPROVAL. LETTER O G By my signature below. I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. I have read this application and the information I have provided is correct. 1 have rea iption of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to building constr.-� orize repres tatives of Cu e filter the above -identified property for inspection purposes. Signature of Applicant/Agent: Date: �pn��t SUPPLQN "'1 f L INFORMATI;2o�liifion PLAN CHECK TYPE ROUTING SLIP New SFD or Multifamily dwellings: Apply permit for AVER -THE -COUNTER El BUILDING PLAN REVIEW existing building(s). Demolition pennit is required prior to issuance of building / permit for new building. ❑ EXPRESS ❑ PLANNING PLAN REVIEW _ Commercial Bldgs: Provide a completed Hazardous Materials Disclosure ❑ STANDARD ❑ PUBLIC WORKS form if any Hazardous Materials are being used as part of this project. ❑ LARGE ❑ FIRE DEPT Copy of Planning Approval Letter or Meeting with Planning prior to ❑ MAJOR ❑ SANITARY SEWER DISTRICT submittal of Building Permit application. ❑ ENVIRONDIENTAL HEALTIi BldgApp_2011.doc revised 03/16/11 CITY OF CUPERTINO FEE ESTIMATOR — BUILDING DIVISION NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School District, etc.). These fees are based on the Preliminary information available and are only an estimate. Contact the Dept for addn'l info. FEE ITEMS (Fee Resolution 11-053.LE 7/1113) ADDRESS: 10374 S Tantau DATE: 12/01/2015 REVIEWED BY: PAUL he oe: APN: 375 08 032 BP#: *VALUATION: 1$3,901 "PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY SFD or Duplex USE: P11:,od'. hil-' T"v: PENTAMATION 1GENRES PERMIT TYPE: WORK Install (N) siding on front and right side exterior (290 S.f.) SCOPE NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School District, etc.). These fees are based on the Preliminary information available and are only an estimate. Contact the Dept for addn'l info. FEE ITEMS (Fee Resolution 11-053.LE 7/1113) FEE QTY/FEE MISC ITEMS he oe: T .'f'£;. 1>.lt'G, t't'?'rTdit �`r'd: = S.f. $431.00 L F1 M P11:,od'. hil-' T"v: $0.00 NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School District, etc.). These fees are based on the Preliminary information available and are only an estimate. Contact the Dept for addn'l info. FEE ITEMS (Fee Resolution 11-053.LE 7/1113) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 = S.f. $431.00 Siding ISIDEOTHEI? All Other Suppl. PC Fee: (F) Reg. 0 OT M hrs $0.00 PNM Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Fee:E) Reg. 0 OT 0.0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 oer"s I'M, 410�? 1*01'k': F1 Fec: 0 (F) Work Without Permit? 0 Yes (E) No $0.00 Advanced Planning Fee: $0.00 Select a Non -Residential E) Building or Structure 0 • 1,11"Ces, Strong Motion Fee: I BSEUSMICR $0.51 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $1.00 SUBTOTALS:. $1.51 $431.00 TOTAL FEE: Revised: 10/01/2015 Mr, CUPERTINO U z Building Department OFFICE COPY L' ff .,0 12Oqq 15 ::D�C D CD c) REVIEWED FOR CODE CO z Reviewed By: Tom` '� w o :�E Q LU Q O w w C Cl- => LU N U T O 2 COMIMIUNITY DE'vELOPMENT DEPARTMENT w BUILDING DIVISION - CUPERTINO APPROVED ot This set of plans and specifications kILjST be kept at the t job site during construction. It is unlawful to make any changes or alterations on same, or to deviate therefrom, without approval from the Building Official. 4? The 'Stamping of this plan and specifications SHALL NOT be held to permit or to be an approval of the violation -} .� of any, -vision C of any City Ordinance or State Law. BY L-UI Yy V LU DATE. PERMIT #j 51,9z w o > LO ZD w �U LU o ENTRY -J ¢ cn INSTALL 290 SO. FT. VINYL �- w SIDING FRONT GABLE & LEFT o U SINGLE LEVEL HOME(FRONT YARD) SIDE WALL OF THE HOME � '- 'AT' 11.23.15 FLOOR PLAN S TANTAU AVENUE COLOR = PLATINUM GRAY SCALE NTS p DRAWN BY DKW 'DE 19572463A - •. ' SHEE A-1 10401 S Tentau AveJj% .ty •. >.�f %^r , y_S R� ��,'ty L • • Gupenlno,Callornia a .dI ,_ �'t+o f ! • . ... • 4z.i. . I IV. street view - Oct 2014 � �^ a � 4 3; A +� t t :. ' � • ry, . .. 144, • s•a, t �.�AOF �! 10374 S' All, Tilson Ave Phil Ln • "" '�-�rlrr� Google ,. ■E■ Back to MapImage capture Oct 2C 14 B 2015 Google T- Privacy Repot a problem 1;54 PM :: Searcn the wet; ana VVlnaows [❑] ■ ► ■ ,� �' IL ^ %3F 49 IF11/26/2015 A1� st a ICC -ES Evaluation Rep5ort ESR -1728 '00*,Reissued May 2015 TMOThis report is subject to renewal May 2016. www.icc-es.org 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council° DIVISION: 07 00 00—THERMAL AND MOISTURE Staggered Shakes, Transition Starter, Perfection PROTECTION Shingles) Section: 07 46 33—Plastic Siding 1.0 EVALUATION SCOPE REPORT HOLDER: FOUNDRYTm—THE TAPCO GROUP (A HEADWATERS COMPANY) 200 SHOTWELL DRIVE FRANKLIN, OHIO 45005 (800) 771-4486 www.foundrysiding.com EVALUATION SUBJECT, FOUNDRY PREMIUM VINYL SIDING ADDITIONAL LISTEES: Compliance with the following codes: 1VIRD■ 2009 and 2006 International Building Code® (IBC) ■ 2009 and 2006 International Residential Code® (IRC) w ■ 2013 Abu Dhabi International Building Code (ADIBC)t tThe ADIBC is based on the 2009 IBC. 2009 IBC code sections referenced in this report are the same sections in the ADIBC. Properties evaluated: ALSIDE 3773 STATE ROAD CUYAHOGA FALLS, OHIO 44223 (330) 922-7627 (Profiles distributed under the Architectural Classics brand name: Shakes, Shingles, Rounds, 10" Staggered Shakes, Transition Starter) EXTERIOR PORTFOLIOIROYAL BUILDING PRODUCTS 1441 UNIVERSAL ROAD POST OFFICE BOX 1058 COLUMBUS, OHIO 43216 (614) 754-3629 (Profiles distributed under the Exterior Portfolio/Royal Building Products Portsmouth "V" Pro Series brand name: Cedar Shingles) KAYCAN LTD. 3075 TRANS -CANADA HIGHWAY POINTE -CLAIRE, QUEBEC H9R 1B4 CANADA (514) 694-5855 (Profiles distributed under the Eagle Rock brand name: Shakes, Shingles, 10" Staggered Shakes, Fish Scale, Half Cove, Octagon, Hexagon, Rounds, Mitered Corner, Transition Starter) NORANDEX BUILDING MATERIALS DISTRIBUTION INC. 300 EXECUTIVE PARKWAY, SUITE 100 HUSON, OHIO 44236 (800) 528-0942 (Profiles distributed under the Home Accents brand name: Shakes, Shingles, Rounds, Fish Scale, 10" ■ Durability ■ Exterior veneer ■ Wind load resistance ■ Ignition resistance 2.0 USES Foundry Premium Vinyl Siding products are used as exterior wall coverings over an approved sheathing capable of supporting the imposed loads. 3.0 DESCRIPTION Foundry Premium Vinyl Siding products are extruded from polyvinyl chloride (PVC) and acrylic based resins and conform to the requirements of ASTM D3679. The siding is available in a range of colors, textures, and profiles. The siding is produced in a nominal wall thickness of 0.040 inch. Refer to Table 1 for the profile names and related descriptive information. Siding accessory products, such as outside corners, starter strips, J -channels and utility trim are manufactured from the same material as the siding. 4.0 DESIGN AND INSTALLATION 4.1 General: Installation of Foundry Premium Vinyl Siding products must comply with the prescriptive requirements of 2009 IBC Section 1405.14, 2006 IBC Section 1405.13, or IRC Section R703.11.1, Section R703.4, and Table R703.4, as applicable, ASTM D4756, this report, and the manufacturer's published installation instructions. The manufacturer's published installation instructions must be available at the jobsite at all times during installation. Flashing in accordance with the applicable code must be installed at all openings, penetrations, and abutments with dissimilar materials, and at terminations of the sidings and soffit. Siding fasteners must be long enough to penetrate a minimum of 1 inch (25.4 mm) into the substrate or through ICC -ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not spectfically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. i��1 (0 MU0 MWM --- Copyright Copyright © 2015 Page 1 of 3 ESR -1728 1 Most Widely Accepted and Trusted Page 2 of 3 the plywood, as applicable, and must be installed through the center of the nailing slots, leaving a minimum '/a -inch (3.2 mm) space between the fastener head and the face of the vinyl nailing hem, so as not to restrict movement due to expansion and contraction. The fastener spacing is as designated in Table 1. Panels must be able to expand and contract. If the outside temperature is 50°F (10°C) or above, a 3/8 -inch - wide (9.5 mm) gap must be provided at the siding, panel ends. If the temperature is below 50°F (10°C), a /2 -inch - wide (12.7 mm) gap must be provided at the siding panel ends. The bottom corners of the shake, shingle and staggered shake products must be installed on the top step of the wood grains of the lower panels. The siding must not be nailed tightly. Accessory materials such as outside corners, starter strips, J -channels and utility trim must be installed in accordance with the manufacturer's published installation instructions and the applicable code. A minimum 3/8 -inch (9.5 mm) clearance is required on all J -channels and stops to allow for panel expansion and contraction. 4.2 Wind Resistance: 4.2.1 General: The design wind pressure must be determined in accordance with the requirements of Chapter 16 of the IBC or Section R301.2.1.1 of the IRC, as applicable, and must not exceed an allowable wind load of 35.9 psf, subject to the conditions in Sections 4.2.2 and 4.2.3 of this report. Wind resistance of soffit panels is outside the scope of this report. 4.2.2 IBC: For buildings constructed under the requirements of the IBC, vinyl siding must be installed as described in IBC Section 1405.14 and Section 4.1 of this report, over sheathings or materials addressed in IBC Section 2304.6 that are capable of independently resisting both positive and negative wind pressures occurring under design conditions at the building location. The allowable negative wind load for the vinyl siding shown in Table 1 is 35.9 psf for the IBC; the sheathing must be capable of withstanding the indicated negative load, or greater. Positive wind pressures are not considered for the siding, since the sheathing must be capable of supporting the imposed loads, including but not limited to, positive and negative transverse wind pressures. 4.2.3 IRC: For buildings constructed in accordance with the 2009 IRC, the sidings must be installed as described in Section 4.1 and in accordance with one of the following conditions: 1. For installation over sheathing other than foam plastic sheathing, in applications where the building's mean roof height does not exceed 30 feet and the basic wind speed (3 -second gust) is less than 110 mph (49 m/s) in Exposure B, and does not exceed 90 mph (40 m/s) in Exposure C or 85 mph (37 m/s) in Exposure D, sheathing must be as required by Table R703.4 of the IRC. Use of the siding under conditions exceeding those above is outside the scope of this report. 2. For installation over foam plastic sheathing, the siding must be installed in accordance with Section R703.11.2 of the 2009 IRC. 4.2.4 Negative Wind Pressures: Allowable negative wind pressures for siding installed over sheathing materials not addressed in Sections 4.2.2 or 4.2.3 are outside the scope of this report. 4.3 Ignition Resistance: When installed in accordance with the Section 1406.2.2 of the 2009 IBC on exterior walls on buildings of Type I, II, III or IV construction, the siding is permitted to be installed at a fire separation distance of less than 5 feet (1524 mm) in accordance with IBC Section 1406.2.1.1. When installed in accordance with the 2006 IBC on exterior walls on buildings of other than Type V construction, the siding is permitted to be installed at a fire separation distance of less than 5 feet (1524 mm) in accordance with IBC Section 1406.2.1.1. When the exterior wall is required to be fire - resistance -rated, the fire separation distance must be in accordance with Section 705.5 of the 2009 IBC or Section 704.5 of the 2006 IBC, as applicable. 5.0 CONDITIONS OF USE The Foundry Premium Vinyl Siding products described in this report comply with, or are suitable alternatives to what is specified in, those'codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 Installation must comply with this report, the manufacturer's published installation instructions and the applicable code. In the event of a conflict between the manufacturer's published installation instructions and this report, this report governs. 5.2 Exterior walls must be braced or sheathed to resist racking loads with approved materials in accordance with the requirements of the applicable code. 5.3 Except as provided in Section 4.2.3, the siding must be installed only on exterior walls covered by wood structural panel sheathing capable of supporting the imposed loads, including but not limited to positive transverse wind loads, and covered by a water - resistive barrier. 5.4 The Foundry Premium Vinyl Siding products are manufactured in Franklin, Ohio, under a quality control program with inspections conducted by ICC - ES. 6.0 EVIDENCE SUBMITTED 6.1 Data in accordance with the ICC -ES Acceptance Criteria for Vinyl Siding (AC37), dated February 2014. 6.2 Report of ignition resistance testing in accordance with NFPA 268. 7.0 IDENTIFICATION The Foundry Premium Vinyl Siding products described in this report must be identified by a stamp or label bearing the manufacturer's name (The Foundry"""), the product type, the statement "Conforms to ASTM Specification D3679," and the evaluation report number (ESR -1728). ICC -ES Evaluation Report ESR -1728 FBC Supplement Reissued May 2015 This report is subject to renewal May 2016. wwwkc-es.org 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 46 33—Plastic Siding REPORT HOLDER: FOUNDRY""—THE TAPCO GROUP (A HEADWATERS COMPANY) 200 SHOTWELL DRIVE FRANKLIN, OHIO 45005 (800) 771-4486 www.foundrvsidina.com EVALUATION SUBJECT: FOUNDRY PREMIUM VINYL SIDING 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that Foundry Premium Vinyl Siding, recognized in ICC -ES master report ESR -1728, has also been evaluated for compliance with the codes noted below. Applicable code editions: ■ 2010 Florida Building Code—Building ■ 2010 Florida Building Code—Residential 2.0 CONCLUSIONS Foundry Premium Vinyl Siding, described in Sections 2.0 through 7.0 of the master evaluation report ESR -1728, complies with the 2010 Florida Building Code—Building and the 2010 Florida Building Code—Residential, provided the design and installation are in accordance with the International Building Code® provisions noted in the master report and the following conditions apply: ■ Design wind loads must be based on Section 1609 of the 2010 Florida Building Code—Building or Section 301.2.1.1 of the 2010 Florida Building Code—Residential, as applicable. ■ Load combinations must be in accordance with Section 1605.2 or Section 1605.3 of the 2010 Florida Building Code— Building, as applicable. ■ Installation of horizontal siding profiles over foam sheathing is permitted only under the 2010 Florida Building Code— Residential. The allowable design wind pressure must be adjusted based on the wall assembly construction, in accordance with Section R703.11.2.2 of the 2010 Florida Building Code—Residential. Use of the Foundry Premium Vinyl Siding for compliance with the High -Velocity Hurricane Zone provisions of the 2010 Florida Building Code—Building and the 2010 Florida Building Code—Residential has not been evaluated, and is outside the scope of this evaluation report. For products failing under Florida Rule 9N-3, verification that the report holder's quality assurance program is audited by a quality assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity (or the code official when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the master report, reissued May 2015. ICC -ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as CG�� to airy finding or other matter in this report, or as to any product covered by the report. �� •. Copyright O 2015 Page 1 of 1