Loading...
B-2016-1280 PlansSCOPE OF WORK • SYSTEM SIZE: 318OW DC, 3000W AC • MODULES: (12) HANWHA Q-CELLS: Q.PRO BFR - G4 265 • INVERTER(S): (1) SOLAREDGE TECHNOLOGIES: SE3000 (240V) W/ -ER-US OR A -US • RACKING: SNAPNRACK SERIES 100 UL; FLUSH MOUNT STANDOFF. SEE PEN D02. VICINITY MAP wale hMo, A Ivp a�=r rrrnx �v.9aAa ' ' pi,rihu, Vl h mr n pi amwBp` na m� �enwar .. [1 5 laYnn914ary snaron oc � 3 c o peM lNA • y n B cock uw..y i. ku'pl 4 ,e p f tBlByJemee iownpr dS"�'�'I�°B'A' v s � �nitt.0 E plaspea PJ r rosrQ=5 Rd 8 ra �• N GENERAL NOTES • ALL WORK SHALL COMPLY WITH 2O13 CEO, 2013 CBC,CRC 2013, MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2O13 CEC. • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH 2O13 CEC. • PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35. • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(E) AND 2012 IFC 605.11.2. • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. • 9.23 AMPS MODULE SHORT CIRCUIT CURRENT. • 14.42 AMPS DERATED SHORT CIRCUIT CURRENT (690.8 (a) & 690.8 (b)). • SYSTEM IS NON BALLASTED PL,O'1 LANS C ` CKE BY DATE _ PLANNING DEPT CUPERTINO 9 -1 COMMUNITY BUILDI,, `ERTINO "'` - CUPERTINO APPROVE O set f Nh c s' ecdi a'.iens -£ k ; t a' (ne site It Is U ,,I t0 n" " a„ y J„D changes r i 1 .. rations on s or to d ,me therefrom w - approval from .�_ �,,i do Ot'ic!al. he Stam,i Is r an and g.pecific.v ons SHALL NOT , be held tc pef n . a- to be an a,"prc.a1 cf the ViOlaUon of any Is c -, any C4fy OMi ..nn; e or State Law.DATE BY LI l l PERMIT 41 LEGEND AND ABBREVIATIONS SE SERVICE ENTRANCE Mp MAIN PANEL SP SUB -PANEL LC PVLOAD CENTER SM SUNRUN METER PM DEDICATED PV METER INVERTER(S) WITH INV INTEGRATED DC DISCONNECT AND AFCI FTC]AC DISCONNECT(S) IlEill DC DC DISCONNECT(S) 0 CB COMBINER BOX 0 F_ -I INTERIOR EQUIPMENT LE D1 SHOWN AS DASHED SOLAR MODULES RAIL -o 0 O -- STANDOFFS & FOOTINGS CHIMNEY L� ATTIC VENT [, ] FLUSH ATTIC VENT o PVC PIPE VENT 0 METAL PIPE VENT rA T-VENT 1p SATELLITE DISH FzFIRE SETBACKS HARDSCAPE -PL- PROPERTYLINE SCALE:NTS A AMPERE AC ALTERNATING CURRENT AFCI ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH COMP COMPOSITION DC DIRECT CURRENT (E) EXISTING EXT EXTERIOR CUPERTINO IN® FIRM FRAMING INT INTERIOR Sul ding Depattrnent LBW LOAD BEA MAG MAGNETICalLFE8 e� 20`16 MSP MAINS R (N) NEW R[,VIEWED FOR CODE COMPLIANCE TO SCALE NTS NOT OC ON CENTER Reviewed By: PRE-FAB PRE -FABRICATED PST POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC TL TRANSFORMERLESS TYP TYPICAL V VOLTS W WATTS REV NAME DATE COMMENTS A I I TABLE OF CONTENTS PAGE # DESCRIPTION PV-1.0 COVER SHEET PV-2.0 SITE PLAN PV-3.0 LAYOUT PV-4.0 ELECTRICAL PV-5.0 SIGNAGE B sunrun GILBERT CORREIA, C10, C46 CA CL #750184 2300 ZANKER ROAD, UNIT F, SAN JOSE, CA 95131 PHONE 408]46.3082 FAX 408.894,9294 CUSTOMER RESIDENCE: TEH-HEN YU 1619 JAMESTOWN DR, CUPERTINO, CA, 95014 TEL. (408) 892-4250 APN #: 36610100 PROJECT NUMBER: 102R-619YU DESIGNER: TYLER KINCAID DRAFTER: RBIEL1 SHEET COVER SHEET REV: A.1 1 /27/2016 PAGE PV-1.0 PITCH TRUE MAG PV AREA SITE PLAN - SCALE = 3132" =1'-0" AZIM AZIM (SOFT) AR-01 18- 180- 166- 89.9 ® AR-02 180 900 760 71.9 FIRE SETBACKS (3' TYP) AR-03 18° 1800 1660 53.9 (E) RESIDENCE (N) ARRAY AR-02 (E) DRIVEWAY PL PL PL PL PL PL Q 4 Q CUPERTINO 1 Huilding Departmen Q416 40'-9" Q o REVIEWED FOR CODE COMPLIANC . z 3: reviewed B 0 w a sunrun GILBERT CORREIA, CIO, C46 CA CL #750184 23W ZANKER ROAD, UNIT F, SAN JOSE. CA 95131 PHONE 25'-1" FAX 4 88949294 82 34'-1" a CUSTOMER RESIDENCE: TEH-HEN YU 1619 JAMESTOWN DR, CUPERTINO, CA, 95014 PL L I PL PL -PL PL TEL. (408) 892-4250 APN #: 36610700 PROJECT NUMBER: 102R-619YU - O INV (E) GATE DESIGNER: SE SM (E) GATE TYLER KINCAID DRAFTER: (N) ARRAY AR-01 (N) ARRAY AR-03 RBIEL1 SHEET SITE PLAN REV: Al 1/27/2016) PAGE PV-2.O ROOF TYPE AR-01 CONCRETE TILE [CURVED] AR-02 CONCRETE TILE [CURVED] AR-03 CONCRETE TILE [CURVED] D1 - AR-01 - SCALE: 1/8" = V-0" PITCH: 180 AZIM: 180' ATTACHMENT I ROOF HEIGHT FLUSH MOUNT STANDOFF. SEE PEN D02.1 TWO STORY FLUSH MOUNT STANDOFF. SEE PEN D02. TWO STORY FLUSH MOUNT STANDOFF. SEE PEN D02. TWO STORY ROOF FRAMING DETAIL - SCALE: NTS RIDGE COLLAR TIE @ 5/16" X 4.0" LAG 1 BOLT PER PENETI CONCRETE TILE [CURVEC SOLAR N W. 2X4 RAFTERS, LOAD BEARINI ROOF FRAME FRAME TYPE EXPOSURE MATERIAL ATTIC WOOD RAFTER ATTIC WOOD RAFTER ATTIC WOOD RAFTER D2 - AR-02 - SCALE: 3/32" = 1'-0" PITCH: 180 AZIM: 90° D3 - AR-03 - SCALE: 1/8" =1'-0" PITCH: 18' AZIM: 180° FRAME MAX FRAME SIZE SPAN 2X4 12'-0" 2X4 12'-0" 2X4 8'-0" OC ROOF EDGE MAX RAIL SPACING ZONE SPAN 24" 1'-81, 4'-0" 24" V - 8" 4' - 0" 24" 1' - 8" 4' - 0" MAX RAIL DESIGN CRITERIA OVERHANG MODULES: 3' - 3" HANWHA Q-CELLS: Q.PRO BFR - G4 265 3' 3" MODULE DIMS: 3' - 3" 65.7" x 39.4" x 1.26" MODULE CLAMPS: Portrait: 9.84" - 13.78" Landscape: 0" - 3.94" MAX DISTRIBUTED LOAD: 3.14 PSF MAX POINT LOAD: 39.4 LB TOTAL PV SYSTEM WEIGHT: 610.2 LB SNOW LOAD: 0 PSF WIND SPEED: 110 MPH 3-SEC GUST. LAG SCREWS: 5/16"x4.0": 2.5" MIN EMBEDMENT OUPERTI 3uilding Depal FEBQ 12016 ED FOR CODE COMPLIAN iewed By: 24" OC sunrun it GILBERT CORREIA, 010. C46 CA CL #750184 ROAD, UNIT F, SAN JOSE, CA 95131 CUSTOMER RESIDENCE: TEH-HEN YU 1619 JAMESTOWN DR, CUPERTINO, CA, 95014 TEL, (408) 892-4250 APN #: 36610100 PROJECT NUMBER: 102R-619YU DESIGNER: TYLER KINCAID DRAFTER: RBIELI v*lMISINI LAYOUT REV: A.1 1/27/2016 PAGE PV-3.0 120/240 VAC SINGLE PHASE SERVICE #: OMETER M PG&E 1008283742 UTILITY GRID EXISTING 200A MAIN BREAKER 1 EXISTING SOLAREDGE 200A (N) LOCKABLE TECHNOLOGIES: SE3000 -- MAIN PANEL (N) SUN RUN BLADE TYPE (240V) W/-ER-US ORA-US FACILITY METER AC DISCONNECT 3000 WATT INVERTER 2 JUNCTION BOX 1 PV MODULES LOADS OR EQUIVALENT HANWHA Q-CELLS: Q.PRO BFR - G4 265 �\ �3 M O 3 owe --a 3 s �•� + // / (12) MODULES OPTIMIZERS WIRED IN (1) SERIES OF — _� (12)OPTIMIZERS _ CUPERRTINO ury 20A PV cncuxo 250V METER SQUARE D LOAD RATED DC SOLAREDGE POWER OPTIMIZER Building bepatnent BREAKER AT SOCKET DU221RB DISCONNECT & AFCI P300OPP ND �25A CONTINUOUS 12200/24 FEB o 12016 OF BOUSITE BAR VAC .-�<) 240V METER ' 200A, FORM 2S REVIEWED FOR CODE COMPLIANCE Reviewea By. .., CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (2) 10 AWG PV WIRE NONE (1) 6 AWG BARE COPPER 2 3/4" EMT OR EQUIV. (2) 10 AWG THHN/THWN-2 NONE (1) 8 AWG THHN/THWN-2 3 3/4" EMT OR EQUIV. (2) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 MODULE CHARACTERISTICS HANWHA Q-CELLS: Q.PRO 265 W BFR - G4 265 OPEN CIRCUIT VOLTAGE 38.01 V MAX POWER VOLTAGE 30.75 V SHORT CIRCUIT CURRENT 9.23 A OPTIMIZER CHARACTERISTICS MIN INPUT VOLTAGE 8 VDC MAX INPUT VOLTAGE 48 VDC MAX INPUT ISC 10 ADC MAX OUTPUT CURRENT 15 ADC SYSTEM CHARACTERISTICS - INVERTER 1 SYSTEM SIZE 3180 W SYSTEM OPEN CIRCUIT VOLTAGE 12 V SYSTEM OPERATING VOLTAGE 350 V MAX ALLOWABLE DC VOLTAGE 500 V SYSTEM OPERATING CURRENT 9.1 A SYSTEM SHORT CIRCUIT CURRENT 15 A NOTES TO INSTALLER: 1. 12 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE. 2. ADD 20 AMP PV BREAKER TO MAIN PANEL. 6-12 AWG BARE COPPER WIRE r \. r / \ � f SS BONDING PINS 5116"-1 B SS BOLT SS SPLIT LOCK WASHER (TORQUE TO 16 FT-LBS) SNAPNRACK GROUND LUG BONDING CHANNELNUT RAIL NOTE: • ALL HARDWARE IS INCLUDED FROM MANUFACTURER • A MINIMUM OF ONE GROUND LUG IS TO BE INSTALLED ON EVERY CONTINUOUS ROW OF MODULES • GROUNDING LUG MAY BE INSTALLED IN EITHER RAIL CHANNEL • GROUNDING LUG MAY BE INSTALLED SO GROUND WIRE IS PARALLEL OR PERPENDICULAR TO RAIL • ENSURE SPLIT LOCK WASHER IS INSTALLED ON TOP OF COPPER WIRE SNAPNRACK GROUNDING SCALE: NTS PER CODE: 690.52 LABEL LOCATION: OC DISCONNECT, INVERTER (PER CODE: CEC 690.35(F)) [To be used when inverter is ungrounded] LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: CEC 690A7(E)) LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION PER CODE: CEC 690.17(E), CB LABEL LOCATION: INVERTER, JUNCTION BOXES (ROOF), AC DISCONNECT (PER CODE: CEC690.13.G.3 & CEC 690.13.G.4) INVERTER1 LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: CEC690.54) LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: CEC 705.12(D)(7)) [Not required if panelboard is rated not less than sum of ampere ratings of all overcumenl devices supplying it] LABEL LOCATION: MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES, AND CABLE ASSEMBLIES AT LEAST EVERY 10 FT, AT TURNS AND ABOVEIBELOW PENETRATIONS AND ALL C0MBINERMUCTION BOXES. (PER C0DE: IFC605.11.1.4) LABEL LOCATION: DISCONNECT, POINT OF INTERCONNECTION (PER CODE: CEC690.13(B)) LABEL LOCATION: WEATHER RESISTANT MATERIAL, DURABLE ADHESIVE, UL969 AS STANDARD TO WEATHER RATING (UL LISTING OF MARKINGS NOT REQUIRED), MIN 3%" LETTER HEIGHT ARIAL OR SIMILAR FONT NON -BOLD, PLACED WITHIN THE MAIN SERVICE DISCONNECT, PLACED ON THE OUTSIDE OF THE COVER WHEN DISCONNECT IS OPERABLE WITH SERVICE PANEL CLOSED. (PER CODE: CEC690.15, 690.13(B)) LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: CEC 705.12(D)(4)) PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: CONDUIT, COMBINER BOX (PER CODE: CEC690.31(G)(3)(4) & CEC 690.13(G)(4) LABEL LOCATION: DC DISCONNECT, INVERTER (PER C0DE: CEC690.53) ADHESIVE FASTENED SIGNS: • THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. • WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS, AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4 (NEC 110.21(B) FIELD MARKING). • ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT IIFC 605.11.1.31 CUPERTINO Ruilding Departmel FEB f 120115 REVIEWED FOR CODE keviewed By. CAUTION: POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN ®LAR PANEL@ ON ME6N SERVICE ENTRANCE AND PV BREAKER DISCONNECT INVERTER LOCATI MAIN PANEL AC DISCONNECT SUNRUN METER 1619 JAMESTOWN DR, CUPERTINO, CA, 95014 CUPERTINO Building Department FEB it 12016 REVIEWED FOR CODE COMPLIANCE reviewed By, --