Loading...
B-2016-1291 PlansAssessor's Parcel Number: Lt:� 2 (� Name of Owner: .AnQ,.�pr�(� (�P.p p /, J� Contact Person: ' J ��1jE2t��l�Y (�tC2Y �l Phone: l' � `9�� Project Address:- 1 v J may-y av Scope of Work: �eL�Nlkacey- � iI d0-5 Ce7c,sfi'"9 �hyoo-, "o -two bo!rbYDrks, Code Editions: 2013 California Residential Code 2013 California Plumbing Code 2013 California Mechanical Code 2013 California Electrical Code 2013 California Energy Code Mechanical Notes; 1. Bathroom vents shall terminate not less than 3 feet from openings and property lines. (CMC 504A) Energy Code Mandatory Measures, 1. All permanently Installed high efficacy luminaires shall be switched separately from low efficacy luminaires (150(k)(7)) 2. Permanently installed luminaires in bathrooms shall be high efficacy luminaires OR are controlled by an occupant sensors(s) certified to comply with Section 119 that does not turn on automatically or have an always on option. (150(k)(10)) F>F � CUPERTINO 1 g�! Building Department REVIEWED FOR CODE COMPLIANCE Reviewed By rfi�w 1t __ ._ . -.. _ _.._ 197 rl - ----- - ------ CxIS`ft1,l4' 6AT4490OV) Plumbing Notes 1. Water closets shall have an average water consumption of not more than 1.28 gallons per effective flush. (CPC 403.2) 2. Shower heads shall have a water flow not exceed 2.0 gallons per minutes @ 80 psi, (CPC 408.2) 3. Faucets In lavatories shall have a water flow not exceed 1.5 gallons per minutes @ 60 psi and shall not be less than .8 gallons per minutes at 20 psi. (CPC 403.6) 4. Shower stalls shall have a clear Interior finish area of 7.1 sq.ft. and be able to accommodate a minimum 30 Inch circle at the threshold level. These clearances shall be maintained up to a height of 70 inches able the shower drain. (CPC 40B.6) 5. Shower compartments and walls above bathtubs with installed shower heads shall be finished with a smooth, nonabsorbent surface to a height not less than 72 inches (6ft). (CRC R307.2) 6. The maximum hot water temperature discharging from the bathtub, shower and whirlpool bathtub filler shall be limited to 120 degrees Fahrenheit, The water heater thermostat shall not be considered a control for meeting this provision. (CPC 409.4 & 408.3) 7. Water closet shall be set minimum 15 inches from its center to a side wall or obstruction and 24 inch clearance In front of water closet. (CPC 402.5) Electrical Notes; 1. The installation of smoke alarms in all of the following areas shall be provided: (R314.3) i a. On the telling or wall outside of each separate sleeping area in the Immediate vicinity of bedrooms. ! b, In each room used for sleeping purposes. C. In each story within a dwelling unit, including basements but not including crawl spaces and uninhabitable attics. 2. Approved carbon monoxide alarms shall be Installed outside of each separate sleeping area in the Immediate vicinity of the bedrooms and on every level including basements in dwelling units that have fuel -fired appliances or attached garages. (CRC R315.1) 3. At least one 20 amp branch circuit shall be provided to supply bathroom receptacle outlets, Such circuits shall have no other outlets. (CEO 210.11(C)(3)) 4. All receptacles In bathrooms, garages, accessory buildings, outdoors, crawl spaces, unfinished basements, kitchens (where receptacles serve countertop surfaces), laundry, utility, wet bar sinks (within 6 feet of the edge of the sink), shall have ground -fault circuit interrupter (GFCI) protection, (CEO 210.8) 5,In a a Ss e fep Ip 2DII�2�Wand 20-ampere receptacles shall be listed tamper -resistant receptacles. (CEC 406.11)COMMUNITYBUILDING DIVISION - CUPERTINO APPROVED TFjis set of plans and specificalicrs CI; ST t.e kepf at the job site during cans uctlan. It is :o make any changes or alterations on same, or to deviate therefrom, without approval from trig Banding Official. The Stamping of this plan and specs° 1i�jns SHALL NOT be held to permit or to be an ap, IC 3' of the violation of anyp Islons pf any Cjty Ordinance or State La-.v. B1 i +rule ��Ll1.LIVl�1. -- DATE' C1l PERMIT# ��run �t�LL 1 itI i of «A h d 7� EXISTING BATHROOM FLOOR PLAN PROPOSED BATHROOM FLOOR PLAN