B-2016-1300
CITY OF CUPERTINO BUILDING PERMIT HOMESTEAD RD CUPERTINO, CA 95014 (326 Ol 026) NAME: HAM JAYNE YEH PHONE: 408-777-0177 Class 9 Lie. Date 02LO312016 hereby affirm that I am licensed under the provisions of Chapter 9 (commencing ith Section 7000) of Division 3 of the Business & Professions Code and that my cause is in fug force and effect. hereby affirm under penalty of perjury one of the following two declarations: r. I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Seaton 1111 of the Labor Code, for the performance of the work for which this permit is issued. 1 a I have and will maintain Worker's Compensation Insurance, as provided for �! by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save Indemnify and keep harmless the City of Cupertino against liabilities, Judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all nopjt-point source regulations per the Cupertino Municipal Code, Section 9.1B. a : - t t .pit➢L3 hereby affirm that I am exempt from the Contractor's License Law for one of the d owing two reasons: a. I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec,7044, Business & Professions Code) z. I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.7044, Business & Professions Code), hereby affirm under penalty of perjury one of the Following three declarations: a. I have and will maintain a Certificate of Consent to self-imure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. z. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3. 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California, If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked, I certify that I have read this application and state that the above Information Is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save Indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations. per the Cupertino Municipal Code, Section 9.18. IONTRACTOR: PERMIT NO: B-2016-1300 PLATINUM ROOFING SC) AN JOSE, CA 95133 DATE ISSUED: 02/03/2016 PHONE NO: 408-280-5028 IUILDING PERMIT INFO: , BLDG —ELECT —PLUMB _ MECH _ RESIDENTIAL X COMMERCIAL OR DESCRIPTION: NSTALL TPO OVER (E) BUR (72 SQ'S) (WELLS FARGO BLDG) 'q. Ft Floor Area: Valuation:$25033.00 LPN Number: Occupancy Type: 2601026 PERMIT EXPIRES IF WORK IS NOT STARTED WITHIN 180 DAYS OF PERMIT ISSUANCE OR 180 DAYS FROM LAST CALLED INSPECTION. sued by: MELISSA��� RE -ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining n inspection, I agree to remove all new materials for inspection, Signature of Applicant: Date: 02/03/2016 BE CLASS "A" OR BETTER HAZARDOUS MATERIALS DISCLOSURE I leave read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. 1 will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I will maintain compliance with the Caper�4m Municipal Code, Chapter 9.12 and the Health & Safety Code, Se .lions 25505, 25533, and 25534. Owner or authorized agent: Date: 02/03/21116 TRU ION LENDING AGENC I hereby affirm that there is a construction lending agency for the performance of work's for which this permit Is Issued (Sec. 3097, Clv C.) Lender's Name Address understand my plans shall be used as public records. Date 02/03/2016 Id REROOF PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 - FAX (408) 777-3333 • buildinpCu?cupertino.orp B_Zaf(,� - 0 (3a0 PROJECT ADDRESS /� K-�14 l� ',(G/¢ c>ooGI �j�. /� U,r� - �� �� APN # 0 GMAIIL OWNERNAMB 1�f .��5e.1 U H NE _-O,�L�D E. STREET ADD uh Cy) r, , n a.{-'�o I CITYSTAe, ZIP �A p ,. ^�m FAX 'H-E-MAIL , CONTACT NAME `©� (' STRE T ADDRES��SV�/�pp,.���//�� qn ' Ai TY, TATEq,,rZ�[P //��1,51 \ FAX ❑ OWNER ❑ OWNER -BUILDER ❑ OWNER AGENT IJ CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑'TENANT CI C OR NAME f+� � LICITN �ER ✓/ LICE TYPE Tt )� BUS. LTC. k-�Z��a C� E-MAIL FAX STREET ADDRESS CI_SSTATE, ZI4�bC rl( ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS. LIC,# COMPANY NAME E-MAIL FAX .STREET ADDRESS - CITY, STATE, ZIP PHONE USE OF ❑ SFD or Duplex ❑ MUili-Family ROOF AREA: �Q rt / VALUATIO-N�: 0 �� v� STRUCTURE: �-ninmmeercial Io�3 .0c) EXISTING ROOF TYPE: U RUILT-UP ROOF ❑ ASPHALT SHINGLES ❑ WOOD SHAKES ❑ WOOD SHINGLES ❑ OTHER (SPECIFY) REMOVE/REPLACE ❑YES IP NO, PLYWOOD 0 h' El ElOSB PITCH: ROOF ❑ NO ALAYERS'. TIECKNESS' ❑ 5/8', TYPE: El Cox ' 12 CLASS A PROPOSED ROOF TYPE: ❑ BUILT-UP ROOF ❑ ASPHALT SHINGLES ❑ WOOD SHAKES ❑ WOOD SHINGLES ❑ OTHER ICC-ES REPORT # DESCRIPTION OF WORK: --r^ffo Il By my signature below, I certify to each oft ollowing: I am the property owner or authorized agent to act on the property owner's behalf. I v read this application and the information I have prov ed is correct. I have read the Description of Work and verify it is accurate. I agree [o comply with applicable local ordinances and state laws relating to buil s ction. I authorize representatives of Cupertino to enter the above--iid7entified property for inspection purposes. Signature of ApplieanNAgent: Date: t/ SUPPLEMEN L INFORMATION REQUIRED -; OFFICE use ONLY PL, N CHECILTYPE 4 xouz rtc siHP - - If building is associated with a Home Owner's Association, provide letter ❑ OVER`TFIE-COUNTER ❑�nU1LD]NG PLANREVIEw � ,�- _ ofapproval frOtnHOA.7777, Provide Planning approval to verify ifthere any restrictions. ❑ ExexEss - ❑'rLANn'INc eLAN REVIEW _' ' Provide copy of Manufacturer's Installation Specifications. ❑ sTAI913ARD ❑'Pule nEPT Provide signed copy of Cupertino's Tear -Off Policy, s ❑ `oTHex: 4 i ReroofApp_2011.doc revised 03/16/11 REROOF TEAR -OFF POLICY COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION ALBERT SALVADOR, P.E., C.B.O., BUILDING OFFICIAL 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • buildina o).cupertino.ora 11 7O U PROIECF ADDRESS D I� /1 i/ OWNER NAME +1� 4 ` / p 1F�., 1. l 1 V J I n �� �j,^'AP^Nk P NVJ� fP�I ^']_ram_ 1 1 E-MAIL STREETAD 111S ,1 YN C Y,.ST�TE, Z(P `N}Jh�)3'l jE$ I� FAX CONTRACro �hl� In l�cj� LICENSE LI T E EUS, Ik C.,k_ (j COMPANYNAME &:MJIAAIILn1FV� FAX( STREET ADDRESS �IOCi - �� �0\7 4�Y` TY, STAT , ZIP �cvn �S-C �GSI`��3 HO �\t?8-2-E'G-S0Z,�` I UNDERSTAND AND AGREE TO THE FOLLOWING: 1. The re -roof project shall comply with all applicable provisions of the 2013 California Codes. 2. An inspection request can be scheduled up to one business day before the requested inspection date. Please schedule inspections online or call (408) 777-3228 from 7:30-3:30pm (Mon-Thurs) or 730- 2:30pm (Friday) to schedule inspection. For Tear -Off and Nailing Inspections, you must also call on the day of the inspection only after that phase of the work is completed. The building inspector will be available within one hour. The hours for this service are: 7:30-10:30am and 12:30-3:30 (Mon-Thurs) and 7:30-10:30am and 12:30-2:30 (Friday). Final Inspections will be given a two hour window. 3. Tear -Off Inspection is required. Any and all dry -rotted wood shall be replaced prior to this inspection. Unless new plywood roof sheathing is proposed throughout, all the nails/fasteners shall be either completely knocked -down or removed prior to this inspection. 4. If plywood is installed, a plywood Nailing Inspection is required. 5. Roofing shall not be applied without first obtaining all prior inspection and written approvals from the building inspector. Any roofing which is applied without first obtaining an approved inspection will require the removal of all new material down to the sheathing so a proper inspection can be performed. 6. A Final Inspection and approval shall be obtained from the building inspector when the re -roofing is completed. To receive a final sign -off, the following items will be verified: a. Flat roofs shall have a minimum of/4" per foot of slope and demonstrate there is no ponding. b. Listings from approved testing agencies for all pre -manufactured products used shall be available on -site to review at the time of the inspection. c. Proper spark arrestor installation, vents painted, gutter/downspouts installed, debris removed. 7. NOTE: If you call for a tear -off or plywood nailing inspection and the work is not complete, you will be charged a re -inspection fee. The re -inspection fee shall be paid before another inspection can be scheduled. By my signing below, I certify each of the ollowing is true: I am the property owner or authorized agent to act on the property owner's behalf. I understand al agree to comply with the re -roof policy stated above. I also understand that smoke detectors and carbon monoxide t ctors are required to be installed in accordance with Sections R314 and R315 of the 2013 California Residential Code. Signature of ApplicantiAgent: �� Dater ReroofPolicy_2014, doe revised 01115114 CITY OF CUPERTINO 10 1 FEE ESTIMATOR - BUILDING DIVISION 23000 HOMESTEAD RD DATE: 02/03/2016 REVIEWED BY: MELISSA V&DD7RFSS: PN: 326 01 026 BP#: B-2016-1300 VALUATION: $25,033 *PERMIT TYPE: Minor Building Permit PLAN CHECK TYPE: Re -roof PRIMARY Commercial Building PENTAMATION 1COMMLROOe USE; PERMIT TYPE: WORK INSTALL TPO OVER E BUR 72 SQ'S WELLS FARGO BLDG ESR - 1463 SCOPE 3�ecXr. AlanCheck Plwob. N(wCheck 1,kc, 0'/an('1rec6 Mech. P,=.rxtt Fee: Phwo5, Fernald hive: 1,Ckro. Pe'nih 1,oe Oeher .,W,h. hup. Oen:rNwph 1ns7>. Oiiw, L",c. insp_ ,i;lerh. frap, kee Phurr). low. Fez: t3ku:. ;rise. 1 ce: NOTE. This estimate does not includefees thte to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School Distriel. atr_). Those Pepe mw hosed on the nreliminary information available and are only an estimate. Contact the Dent Mr addn't into. FEE ITEMS (Fee Resolution 1.1-053 E . 711113) FEE QTY/FEE MISC ITEMS C:heckyy bee., {Plan ',l. lee l :fyyippi, 1,C Permit Fee: $573.00 SuppL Itt_kI, Fee F'7tun1.:'itt=t;lt.:1s`lec Pormh F(,e: �. Ot7S11°tfC"Ptflil 7*ac 11dmiuistralise Free: Work Without Permit? 0 Yes E) No $0.00 Aclvaxncexl.Ptt nnin Fees: d It'awd Documentation beek. Strong Motion Fee: iBSEISMICD $7.01 1 Select an Administrative Item Blda Stds Commission Fee: 1BCBSC $2.00 SUBTOTALS:` $582.01 $0.00 TOTAL FEE.:' $582.01 Revised: 01/01/2016 Nonresidential Re -Roofing ?('�17 (-inn�-�-�� .r'{�fi•• i�F� I?li'. �_�!_I': (.Ifl' Permit DATE: fl 3 1 16 Permit NUMBER: �3od CA Climate Zone: Permit ADDRESS:9�30bp �WA2S�(.aA 2-D City zip: CX)V_arAr- Yy0 (k - 015(0) p COOL RDOr - IS i'10 T REit PED If any of the boxes below are checked. Cool Roof Exemptions: Check any that apply. I] Roof area is over unconditioned space (e.g. warehouse) or process space (e.g. manufacturing) ❑ Area to be re -roofed does not exceed 2,000 ftz OR 50% of total roof area, whichever is greater Area to be re -roofed = ft2 Total roof area = ft, Cool Roof Exceptions: Check any that apply. 0 In CZ 3, wood -framed roof has a U-factor 5 0,039 CI In CZ 3, metal building roof has a U-factor 5 0.048 Roof constructions that have thermal mass with a weight of > 25 Ib/ft2 over the roof membrane COOL ;Off IS REQUIRED If none of the boxes above are checked. Table 1. Prescriptive Requiren+ents for COOL ROOFS Circle the applicable requirements. *Solar Reflective Index values must be calculated, see Page 2 of this guide. Nonresidential Buildings Low -sloped roof pitch 5 2:12 3 year Aged Solar Reflectance, minimum AND Thermal Emittance, minimum 0.63 0.75 OR Solar Reflective Index, minimum* 75 Steep -sloped roof pitch > 2:12 3 year Aged Solar Reflectance, minimum AND Thermal Emittance, minimum 0.20 0.75 OR Solar Reflective Index, minimum* 16 Hotel, Motel, and High-rise Residential Buildings Steep -sloped roof pitch > 2:12 All roof weights 3 year Aged Solar Reflectance, minimum AND Thermal Emittance, minimum 0.20 0.75 OR Solar Reflective Index, minimum* 1 16 Optional: For nonresidential buildings with low -sloped roofs, the 2013 code allows a tradeoff between increased roof/ceiling insulation and reduced Aged Solar Reflectance values. To use this option, circle the actual 1-1-factor of the building's roof/ceiling assembly in Table 2, and the corresponding minimum Aged Solar Reflectance value. fecft l I r,,. fi.:r ; c v,-)l:v f._fL...;anc�- Circle the applicable requirements. Roof/Ceiling Insulation Tradeoffs Aged Solar Reflectance Metal Building U-factor Other Building Types U-factor_ 0.62-0.60 0.061 0.036 0.59-0.55 0.054 0.034 0.54-0.50 0.049 0.032 0.49-0.45 0.047 0.030 0.44-0.40 0.043 0.028 0.39-0.35 0.039 0.027 0.34-0.30 0.035 0.025 0.29-0.25 0.033 0.024 Nonresidential Re -Roofing ROC' "i i.,=':? IOI : IS i_IC i 9 t' a1)1; if any of the boxes below are checked. Exception to Roof Insulation Requirements: Check any that apply. '.l Existing roof is already insulated to at least R-7 or has a U-factor less than 0.089 I:l The roof is not exposed to the roof deck or roof recover boards IJ If mechanical equipment is located on the roof and will not be disconnected and lifted as part of the roof replacement, see Section 141.0(b)2Biii of the 2013 Building Energy Efficiency Standards i wi- INSULATION IS REQUIRED if none of the boxes above are checked. iule 3. IAandt tort' Insulation Requirements fof Roof Alterations Circle the applicable requirements. BayREN Climate Zone Z 3 4 Y2 - Nonresidential Buildings Continuous insulation R-value / Roof assembly U-factor R-14 / 0.055 R-8 / 0.082 R-8 / 0.082 R-14 / 0.055 High-rise Residential & Guest Rooms of Hotel/Motel Continuous Insulation R-value /Roof assembly U-factor R-14 / 0.055 R-14 / 0.055 R-14 / 0.055 R-14 / 0.055 Buildings ui?x it g lna,nectorc Roofing material must have a Cool Roof Rating Council (CRRC) package label indicating compliance with the requirements in the table above, If re -roofing involves a field applied liquid coating, see Section 110.8(i)4, Table 110.8-C of the 2013 Building Energy Efficiency Standards. 1 aI,'.d Fo rrriaS: o NRCC-ENV-02-E: Certificate of Compliance for Envelope Component o NRCI-ENV-01-E: Certificate of Installation for Envelope (from installing contractor, before field inspection) • Cool Roof Rating Council (CRRC) label indicating compliance with applicable requirements If Applicable: NRCC-ENV-03-E: Solar Reflectance Index Calculation Worksheet (if this value is used instead of Aged Solar Reflectance and Thermal Emittance values) ter; f 0"f`s ?'F'.-`+al 'Oa 2013, 7 16,? 2e, °Part 5 r' qti irerile o Visit ww4,,J.energy.ca.gov/title24/2013standards/ o Contact the energy code hotline at (800) 772-3300 or email: t1tle24@energy.state.ca.us o Contact the BayREN Codes & Standards Program by email: codes@bayren.org ICC-ES Evaluation Report ESR-1463* Reissued July 2014 This report is subject to renewal October 2016. www.icc-es.org 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 53 23—Ethylene-Propylene-Diene-Monomer Roofing Section: 07 54 19—Polyvinyl-Chloride Roofing Section: 07 54 23—Thermoplastic-Polyolefin Roofing REPORT HOLDER: CARLISLE SYNTEC POST OFFICE BOX 7000 CARLISLE, PENNSYLVANIA 17013 (717)245.7000 www.carlisle-syntec.co m EVALUATION SUBJECT: CARLISLE EPDM, PVC AND TPO SINGLE -PLY ROOFING MEMBRANES ADDITIONAL LISTEES: KELLY COMPANY/2001 INC. 325 THOMASTON AVENUE WATERBURY, CONNECTICUT 06702 (203) 575-9220 MULE -HIDE PRODUCTS COMPANY, INC. 1195 PRINCE HALL DRIVE BELOIT, WISCONSIN 53511 (800) 786-1492 VERSICO POST OFFICE BOX 1289 CARLISLE, PA 17013 (800) 992-7663 WEATHERBOND POST OFFICE BOX 251 PLAINFIELD, PENNSYLVANIA 17081 (866) 4715125 1.0 EVALUATION SCOPE Properties evaluated: ■ Weather resistance s Roof covering fire classification ■ Wind uplift resistance ■ Impact resistance 2.0 USES Carlisle ethylene propylene diene monomer (EPDM), polyvinyl chloride (PVC) and thermoplastic polyolefin (TPO) single -ply roofing membranes are used as roof coverings in adhered and mechanically fastened membrane roofing systems. 3.0 DESCRIPTION 3.1 General: The EPDM, PVC and TPO Membrane Roofing Systems described in this report consist of single -ply roofing membranes, insulation where used, barrier board or slip sheet where used, flashing, mechanical fasteners and adhesives that are installed on a combustible or noncombustible deck. See Table 1 for Carlisle product trade names and corresponding product names for Mule - Hide Products Company, Inc., WeatherBond, Versico and Kelly Company/2001 Inc., the additional listees. 3.2 EPDM Membranes: 3.2.1 Sure -Seal: Sure -Seal is a black, nonreinforced EPDM membrane, 45 mils thick [0.045 inch (1.14 mm)]. 3.2.2 Sure -Seal FIR: Sure -Seal FIR is a black, nonreinforced EPDM membrane with fire retardants. Available thicknesses range from 45 mils (0,045 inch 11.14 mm]) to 90 mils (0.090 inch [2.29 mm]). 3.2.3 Sure -White: Sure -White is a white, nonreinforced EPDM membrane. It is available in thicknesses of 60 mils [0.060 inch (1.52 mm)] and 90 mils [0.090 inch (2.29 mm)]. 3.2.4 Sure -Tough: Sure -Tough is a black, reinforced membrane consisting of a polyester reinforcement encapsulated between two EPDM membrane plies. It is available in thicknesses ranging from 45 mils [0.045 inch (1.14 mm)] to 75 mils [0.075 inch (1.90 mm)]. Compliance with the following codes: 3.2.5 Sure -Tough FIR: Sure -Tough FIR is a black, reinforced membrane consisting of a polyester ■ 2012 and 2009 International Building Code" (IBC) reinforcement encapsulated between two EPDM * 2012 and 2009 International Residential Cade (IRC) membrane plies with fire retardants. Available thicknesses are 45 mils [0.045 inch (1.14 mm)] and 60 mils [0.060 inch ■ Other Codes (see Section 8.0) (1.52 mm)]. *Revised August 2014 ICC-ES'Evaheitim Reports are nod to be corromed e, representlng aesihed/cs ar any other' athibtdes not specifically addressed, nor are they to be construed ns mt endorsement of the,abject of the report e, a reconvnendotlon for' its use. there is no war'rmt.y by IL'CEvaluedeo Service, LLC, express m implied, as E to any finding aother matter' la ibis report, or as to any product covered by the report. '-tw '.:. Copyright © 2014 Page 1 of 10 ESR-1463 [ Most Widely Accepted and Trusted Page 2 of 10 3.2.6 Sure -Seal FleeceBACK: Sure -Seal FleeceBACK is a 45-mil to 90-mil [0.045 inch to 0,090 inch (1.14 mm to 2.29 mm)] non -reinforced EPDM bonded to a 5.5-ounce- per-square-yard (0.18 kg/m2) polyester fleece. Available product thicknesses range from 100 mils [0.100 inch (2.55 mm)] to 145 mils [0.145 inch (3.68 mm)]. 3.2.7 Sure -White FleeceBACK: Sure -White FleeceBACK is a 45-, 60- or 90-mil [0.045, 0.060 or 0.090 inch (1.14, 1.52 or 2.29 mm)] nonreinforced white EPDM bonded to a 5.5-ounce-per-square-yard (0.18 kg/m2) polyester fleece. Available product thicknesses are 100, 115 and 145 mils [0.100, 0.115 or 0.145 inch (2.54, 2.92 or 3.68 mm)]. 3.2.8 Sure -Seal AFX: Sure -Seal AFX is a 45-mil [0.045 inch (1.14 mm) or 60-mil [0.060 inch (1.52 mm)] non -reinforced EPDM bonded to a 7.5-ounce-per-square- yard (0.25 kg/m2) polyester fleece. Available thicknesses are 90 mils [0.090 inch (2.29 mm)] and 105 mils [0.105 inch (2.67 mm)). 3.3 PVC Membranes: 3.3.1 Sure -Flex and Sure -Flex KEE: Sure -Flex and Sure -Flex KEE are membranes consisting of a polyester reinforcement encapsulated between two plies of PVC. The membrane is available in white, gray, tan and custom colors. Available thicknesses range from 50 mils [0.050 inch (1.27 mm)] to 80 mils [0.080 inch (2.03 mm)]. 3.3.2 Sure -Flex FRS: Sure -Flex FRS membrane consists of a fiberglass reinforcement encapsulated between two plies of PVC. The membrane is available in white, gray and custom colors. Available thicknesses range from 50 mils [0.050 inch (1.27 mm) to 80 mils [0.080 inch (2,03 mm)]. 3.3.3 Sure -Flex FleeceBACK: Sure -Flex FleeceBACK is the Sure -Flex membrane, described in Sections 3.3.1 and 3.3.2, with a laminated 5.5-ounce-per-square-yard (0.18 kg/m2) polyester fleece backing. Available thicknesses range from 105 mils [0.105 inch (2.67 mm)] to 135 mils [0.135 inch (3.43 mm)]. 3.4 TPO Membranes: 3.4.1 Sure -Weld: Sure -Weld membrane consists of a polyester reinforcement encapsulated between two plies of TPO. The membrane is available in white, gray, tan and custom colors. Available thicknesses range from 45 mils [0.045 inch (1.14 mm)] to 80 mils [0.080 inch (2.03 mm)]. 3.4.2 Sure -Weld HS: Sure -Weld HIS is the Sure -Weld membrane formulated with an additional flame retardant for fire resistance at higher slopes. The membrane is available in white, gray, tan and custom colors. Available thicknesses are 45 mils (0.045 inch [1.14 mm]) and 60 mils (0.060 inch [1.52 mm]). 3.4.3 SAT-TPO: SAT-TPO is a self -adhered version of the Sure -Weld HIS membrane with adhesive. 3.4.4 Sure -Weld FleeceBACK: Sure -Weld FleeceBACK is the Sure -Weld HS membrane, 45 mils [0.045 inch (1.14 mm)], 60 mils [0.60 inch (1.52 mm)] and 80 mils [0.60 inch (2.03 mm)] thick, with a laminated 5.5-ounce- per-square-yard (0.18 kg/m2) polyester fleece backing. Available thicknesses are 100 mils [0.100 inch (2.54 mm)], 115 mils [0.115 inch (2.92 mm)] and 135 mils [0.135 inch (3.43 mm)]. 3.4.5 Sure -Weld AFX: Sure -Weld AFX is the Sure -Weld HS membrane with a laminated 10-ounce-per-square- yard (0.34 kg/m2) polyester fleece backing. Available thicknesses range from 120 mils [0.120 inch (3.05 mm)] to 155 mils 10.155 inch (3.94 mm)]. 3.4.6 Spectra -Weld: Spectro-Weld is the Sure -Weld membrane, described in Section 3.4.1, formulated with a brighter white color. Available thicknesses are 60 mils [0.060 inch (1.52 mm)] and 80 mils [0.080 inch (2.03 mm)]. 3.4.7 Spectro-Weld FleeceBACK: Spectra -Weld FleeceBACK is the Spectro-Weld membrane with a laminated 5.5-ounce-per-square-yard (0.18 kg/m2) polyester fleece backing. It is 115 mils [0.115 inch (2.92 mm)] thick. 3.5 Insulation: See Tables 2 through 4 for insulations for use with specific roofing systems. Foam plastic insulation, where used, must have a flame -spread index of not more than 75 when tested at the maximum thickness intended for use in accordance with ASTM E84. 3.6 Barrier Board: Barrier board, where used, must be either minimum '/4-inch-thick (6.4 mm� G-P Gypsum Corporation "DensDeck," minimum /4-inch-thick (6.4 mm) Owens Corning "Strataguard", minimum '/4-inch-thick (6.4 mm) USG "Securock," or minimum I/2-inch-thick (12.7 mm) gypsum board. Barrier board must be UL-listed for roofing applications or UL-classified gypsum board. 3.7 Slip Sheet: The slip sheet, where used, must include Carlisle "FR Base Sheet 1S or 2S," GAF "VersaShield® Fire -Resistant Roof Deck Protection (ESR-2053)," Elk "VersaShield FB-1 S or FB-2S, or Atlas FR 10 or FR 50." 3.8 Flashing: Flashing must be provided in accordance with IBC Section 1503.2 or IRC Section R903.2, as applicable. Where flashing is of metal, the metal must be corrosion -resistant, minimum No. 26 gage [0.019 inch (0.483 mm)] galvanized steel. 3.9 Fasteners: Fasteners, used to mechanically attach insulation and membranes to the roof deck, must be corrosion -resistant, and must be Carlisle fasteners, plates or fastening bars, unless otherwise noted in this report. Refer to Table 4 for spacing of fasteners. 3.9.1 HP Fastener: This is an epoxy -coated steel screw used in combination with Carlisle's fastening plates or bars to mechanically attach roofing insulation and membranes to steel or wood substrate. Fastener length must be selected to penetrate through the steel deck a minimum of 3/4 inch (19.1 mm), and into the wood deck a minimum of 1 inch (25.4 mm). 3.9.2 InsulFast Insulation Fastener: This is an epoxy - coated steel screw used in combination with Carlisle's insulation plates to mechanically attach roofing insulation to steel or wood substrates. Fastener length must be selected to penetrate through the steel deck a minimum of 3/4 inch (19.1 mm), or into the wood deck a minimum of 1 inch (25.4 mm). 3.9.3 HP Purlin Fastener: This is an epoxy -coated steel screw used in combination with Carlisle's fastening plates or bars to mechanically attach roofing insulation and membranes to structural steel members. Fastener length must be selected to penetrate through the steel member a minimum of 3/4 inch (19.1 mm.) 3.9.4 HD 14-10 Fastener: This is a heavy-duty, epoxy - coated steel screw used in combination with Carlisle's fastening plates or bars to mechanically attach roofing ESR-1463 I Most Widely Accepted and Trusted Page 3 of 10 insulation and membranes to concrete roof deck. Fastener length must be selected to penetrate into the concrete deck a minimum of 1 inch (25.4 mm). 3.9.5 CD-10 Fastener: The CD-10 is an epoxy -coated, hammer -driven, nonthreaded fastener specifically designed to be used with insulation and seam fastening plates to secure membrane and insulation to structural concrete. Fastener length must be selected to penetrate into the concrete deck a minimum of 1 inch (25.4 mm). 3.9.6 Lite-Deck Fastener: The Lite-Deck Fastener is used in conjunction with a specially designed 3-inch (76.2 mm) Lite-Deck Metal Plate for insulation attachment to gypsum, cementitious wood fiber (Tectum [ESR-11121), and lightweight concrete decks. Fastener length must be selected to penetrate into the deck a minimum of 2 inches (50.8 mm). 3.9.7 GypTec Fastener: The GypTec Fastener is a glass -filled nylon auger fastener designed for securing mechanically attached membranes and insulation to gypsum and cementitious wood fiber (Tectum [ESR-1112]) decks. Fastener length must be selected to penetrate into the deck a minimum of 1.5 inches (38.1 mm). 3.9.8 HP Polymer Seam Plate: This is a 2-inch-diameter (50 mm) polymer plate designed to be used with HP and HD 14-10 fasteners to mechanically attach roofing membranes to the roof deck. 3.9.9 Sure-Tite Fastener and ST Fastening Bar: This is a heavy-duty, epoxy -coated steel screw and bar used to secure reinforced EPDM membranes to steel or wood deck. The bar is 1-inch-wide-by-0.040-inch-thick-by- 10-foot-long (25.4 mm by 1.1 mm by 3.1 m) galvalume- coated steel with prepunched holes 6 inches (150 mm) on center. 3.9.10 HP-X Fastener: This is an epoxy -coated carbon steel screw used in combination with the Piranha Fastening Plate to mechanically attach TPO membranes to steel or wood substrate. Fastener length must be selected to penetrate through the steel deck a minimum of 3/4 inch (19.1 mm), and into the wood deck a minimum of 1 inch (25.4 mm). 3.9.11 Piranha Fastening Plate: This is a 23/8-inch- diameter galvalume-coated steel plate designed to be used with HP-X fasteners to mechanically attach PVC and TPO membranes to the roof deck. 3.9.12 HP-XTRA Fastener: This is an epoxy -coated carbon steel screw used in combination with the Piranha XTRA Fastening Plate to mechanically attach PVC and TPO membranes to steel or wood substrate. Fastener length must be selected to penetrate through the steel deck a minimum of 314 inch (19.1 mm) and into the wood deck a minimum of 1 inch (25.4 mm). 3.9.13 Piranha XTRA Fastening Plate: This is a 23/8-inch-diameter galvalume-coated steel plate designed to be used with HP-XTRA fasteners to mechanically attach PVC and TPO membranes to the roof deck. 3.9.14 PVC Oval Barbed Plate: This is a 1'/2-inch-by- 23/4-inch (35 mm by 69.85 mm) Oval Barbed Plate designed to be used with HP-X Fasteners to mechanically attach PVC membranes to the roof deck. 3.9.15OMG Inc. RhinoBond Plate: The RhinoBond Plate is a 3-inch-diameter (76.2 mm), 0.028-inch-thick (0.7 mm) galvalume-coated steel plate, coated with a proprietary adhesive and used with the HP-X fastener to mechanically attach PVC and TPO membranes to the roof deck. The adhesive bonds the plate to the underside of the membrane. 3.10 Adhesives: 3.10.190-8-30A Bonding Adhesive: 90-8-30A Bonding Adhesive is a high -strength, solvent -based contact adhesive used to adhere EPDM membranes to the insulation or substrate. It has a coverage rate of approximately 60 square feet per gallon (1.5 mz/L). The adhesive is supplied in 5-gallon (18.9 L) containers and has a shelf life of one year. 3.10.2 Aqua Base 120: Aqua Base 120 is a high -strength, water -based contact adhesive used to adhere EPDM, TPO and PVC membranes to the insulation or substrate. It has a coverage rate of approximately 120 square feet per gallon (3 m2/L). The adhesive is supplied in 5-gallon (18.9 L) containers and has a shelf life of one year. 3.10.3 Sure -Flex Low-VOC PVC Bonding Adhesives: Sure -Flex Low VOC PVC Bonding Adhesives is high - strength, solvent -based contact adhesives used to adhere PVC membranes to an insulation or substrate. They have a coverage rate of approximately 60 square feet per gallon (1.5 m2/Q. The adhesive is supplied in 5-gallon (18.9 L) containers with a shelf life of one year. 3.10.4 Sure -Weld Bonding Adhesive: Sure -Weld Bonding Adhesive is a high -strength, solvent -based contact adhesive used to adhere TPO membranes to an insulation or substrate. It has a coverage rate of approximately 60 square feet per gallon (1.5 m'/L). The adhesive is supplied in 5-gallon (18.9 L) containers with a shelf life of one year. 3.10.5 Low VOC Bonding Adhesive: Low VOC Bonding Adhesive is a high -strength, solvent -based contact adhesive used to adhere EPDM and TPO membranes to an insulation or substrate. It has a coverage rate of approximately 60 square feet per gallon (1.5 m2/ L), The adhesive is supplied in 5-gallon (18.9 L) containers with a shelf life of one year. 3.10.6 HydroBond PVC Water -Based Adhesive: HydroBond PVC Water -Based Adhesive is a water -based, wet lay -in, one-sided adhesive to be used to adhere Sure - Flex PVC and PVC Fleece BACK membranes to an insulation or substrate. It has a coverage rate of 100 square feet per gallon (2.5 m21L). The adhesive is supplied in 5-gallon (918.9 L) containers with a shelf life of one year. 3.10.7 Low VOC Bonding Adhesive 1168: Low VOC Bonding Adhesive 1168 is high -strength, solvent -based contact adhesive used to adhere EPDM and TPO membranes to an insulation or substrate. It has a coverage rate of approximately 60 square feet per gallon (1.58 m2/L). The adhesive is supplied in 5-gallon (18.9 L) containers with a shelf life of one year. 3.10.8 Solvent -Free EPDM Bonding Adhesive: Solvent - Free EPDM Bonding Adhesive is a high -strength, polymer - based adhesive. This adhesive can be used to adhere all Sure -Seal or Sure -White EPDM membranes as a one- sided, wet lay -in adhesive. It has a coverage rate of 100 square feet per gallon (2.5 m2/L). The adhesive is supplied in 5-gallon (18.9 L) containers with a shelf life of six months. 3.10.9 Cold Applied Adhesive: Cold Applied Adhesive is a solvent -free, asphalt -modified polyether adhesive. This adhesive can be used with all Sure -Seal or Sure -Weld AFX membranes as a one-sided, wet lay -in adhesive. It has a coverage rate of 67 square feet per gallon (1.6 M2/L). The adhesive is supplied in 5-gallon (18.9 L) containers with a shelf life of one year. ESR-14.63 [ Most Widely Accepted and Trusted Page 4 of 10 3.10.10 FAST Adhesives: FAST 100, FAST 1001-V, FAST Adhesive Dual Cartridge, FAST Adhesive Box Sets, Flexible FAST and FAST Bag -in -a -Box Adhesives are two - component polyurethane adhesives used to adhere FleeceBACK membranes and insulations to various substrates. The adhesives have a coverage rate of approximately 100 square feet per gallon (2.5 mz/L). The adhesives are supplied in 15-gallon (56.7 L) and 50-gallon (189 L) drums, box sets, and cartridge tubes and cylinders, and have a shelf life of one year. 3.10.11 OlyBond 500 Adhesive: OlyBond 500 Spot Shot and OlyBond 500 BA are two -component polyurethane adhesives used to adhere insulations to various substrates. The adhesives have a coverage rate of approximately 100 square feet per gallon (2.5 mz/L). The adhesives are supplied in cartridge tubes and box sets, and have a shelf life of one year. 3.11 Impact Resistance: The EPDM, PVC, and TPO roofing membranes described in this report meet requirements for impact resistance in IBC Section 1504.7, based on testing in accordance with FM 4470. 4.0 INSTALLATION 4.1 General: Installation of the EPDM, PVC, and TPO roofing membranes described in this report must comply with the applicable code, the manufacturer's published installation instructions and this report. The manufacturer's published installation instructions must be available at all times on the jobsite during installation. The substrate to which the membrane is to be applied must be clean, dry, and free of frost, loose fasteners, and other protrusions or contaminates that will interfere with the adhesion or attachment of the membrane or that will puncture the membrane. All materials must be protected against contact with incompatible materials. Where gypsum board is used as barrier board in the roofing assembly, weather protection must be provided to prevent damage to the gypsum board prior to application of the roofing membrane. The slope of the roof on which the single -ply membranes are installed must not be more than the maximum slope indicated for the particular assembly as listed in Tables 2 and 3. Penetrations and terminations of the roof covering must be flashed and made weather tight in accordance with the requirements of the membrane manufacturer and the applicable code. 4.2 Fire Classification: 4.2.1 New Construction: The adhered and mechanically fastened EPDM, PVC, and TPO single -ply membrane roofing systems, when installed in accordance with this report, are Class A, B or C roof covering systems in accordance with ASTM E108 or UL 790, as noted in Tables 2 and 3. 4.2.2 Reroofing: The existing deck must be inspected to verify that the structure to be reroofed is structurally sound and adequate to support and secure the roofing membrane. Prior to installation of new roof coverings, inspection by and written approval from the code official having jurisdiction must be required. Class A, B or C roof covering systems may be installed over existing classified roof covering systems under the following conditions without additional roof classification tests, provided the resulting classification is the lower of the new or existing roofing classification: ■ New uninsulated systems installed only over existing uninsulated assemblies. ■ New insulated systems installed over existing uninsulated systems only. 4.3 Wind Resistance: 4.3.1 New Construction: The allowable wind uplift pressures for the EPDM, 'PVC, and TPO roofing membranes as parts of roof assemblies are noted in Tables 4 and 5. Metal edge securement systems must be listed in accordance with ANSI/SPRI ES-1 and designed and installed for wind loads in accordance with IBC Section 1504.5 and IBC Chapter 16. As an alternate to listed metal edge securement systems for mechanically attached membranes, Carlisle SecurEdge 300 [0.050-inch (1.27 mm) 3003 aluminum] and Carlisle SecurEdge 3000 [0.040-inch (1.02 mm) 3003 aluminum] fascia systems may be used. The maximum allowable load for Carlisle SecurEdge 300 is 234 elf (348 kg/m) and the maximum allowable load for Carlisle SecurEdge 3000 is 200 plf (298 kg/m) based on testing in accordance with ANSI/SPRI ES-1 Test RE-1. 4.3.2 Reroofing: Mechanically anchored systems may be accepted based on the adequacy of anchors penetrating through existing roof coverings into structural substrates. Since the composition and/or condition of any particular existing underlying material may vary widely, reroofing with adhered systems is outside the scope of this report. 5.0 CONDITIONS OF USE The single -ply EPDM, PVC, and TPO roofing membranes described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 Installation must comply with the applicable code, the manufacturer's published installation instructions and this report. The instructions within this report must govern if there are any conflicts between the manufacturer's installation instructions and this report. 5.2 The adhered and mechanically fastened single -ply membrane roofing systems must be installed by professional roofing contractors who are trained and approved by the manufacturer. 5.3 Foam plastic insulation must be separated from the interior of the building by an approved thermal barrier in accordance with IBC Section 2603.4.1.5 or IRC Section R316.4, as applicable. 5.4 Foam plastic insulation, where used, must bear the label of an approved agency indicating that the foam plastic has a flame -spread index of not more than 75 when tested at the maximum thickness intended for use in accordance with ASTM E84 or UL 723, subject to the approval of the code official. 5.5 Design wind uplift pressure on any roof area, including edge and corner zones, must not exceed the allowable wind uplift pressure for the system installed in that particular area. Refer to allowable wind uplift pressures for systems as listed in Table 4. 5.6 The allowable wind uplift pressures listed in Table 4 are for the roof covering system only. The deck and framing to which the system is attached must be designed for the applicable components and cladding wind loads in accordance with the applicable code. ESR-1463 I Most Widely Accepted and Trusted Page 5 of 10 5.7 When application is over existing roofs, documentation of the wind -uplift resistance of the composite roof construction must be submitted to the code official for approval at the time of permit application. 5.8 The roofing membranes are manufactured at Carlisle, Pennsylvania; Greenville, Illinois; Tooele, Utah; and Senatobia, Mississippi, under a quality control program with inspections by ICC-ES. 5.9 For buildings under the IBC, above -deck thermal insulation board must comply with the applicable standards listed in IBC Table 1508.2 or IRC Table R906.2, as applicable. 6.0 EVIDENCE SUBMITTED Data in accordance with ]CC -ES Acceptance Criteria for Membrane Roof Covering Systems (AC75), dated July 2010 (editorially revised April 2014). 7.0 IDENTIFICATION Each roll of the roofing membrane must bear a label noting the product name, the manufacturer's name (Carlisle SynTec) or the name of the additional listee, the manufacturer's address or plant code and the ICC-ES evaluation report number (ESR-1463). 8.0 OTHER CODES In addition to the codes referenced in Section 1.0, the products in this report were evaluated for compliance with the requirements of the following codes: ■ BOCe National Building Code/1999 (BNBC) r 1999 Standard Building Codec (SBC) ■ 1997 Uniform Building CodeTM (UBC) For compliance under the above codes, see Sections 2 through 7 of this report, except revise the following sections to read as follows: 3.8 Flashing: Flashing must be provided in accordance with SBC Section 1503.2, BNBC Section 1508.1 and UBC Section 1509, as applicable. Where flashing is of metal, the metal must be corrosion -resistant, minimum No. 26 gage [0.019 inch (0.483 mm)1 galvanized steel. 3.11 Impact Resistance: The EPDM, PVC, and TPO roofing membranes described in this report meet requirements for impact resistance in BNBC Section 1505.4.2, and SBC Section 1504.6, based on testing in accordance with FM 4470. 4.3.1 New Construction: The allowable wind uplift pressures for the EPDM, PVC, and TPO roofing membranes as parts of roof assemblies are noted in Tables 4 and 5. 5.0 CONDITIONS OF USE The single -ply EPDM, PVC, and TPO roofing membranes described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 8.0 of this report, subject to the following conditions: See Sections 5.1 through 5.8, except revise Section 5.3 to read as follows: 5.3 Foam plastic insulation must be separated from the interior of the building by an approved thermal barrier in accordance with BNBC Section 2603.4.1.5, SBC Section 2603.5.1.5, and UBC Sections 2602.4 and 2602.5.3, as applicable. ESR-1463 I Most Widely Accepted and Trusted Page 6 of 10 TABLE I —PRODUCT NAMES CARLISLE KELLY CO.t MULE -HIDE PRODUCT WEATHERBOND PRODUCT PRODUCT NAME 2001 INC. NAME VERSICO PRODUCT NAME NAME PRODUCTNAME Sure -Seal PREMIUM, C-EPDM-C Mule -Hide Standard EPDM Versigard Nan -reinforced EPDM WeatherBond RBR EPDM Non - STANDARD Membrane reinforced Membrane Sure -Seal FR C-EPDM-C Mule -Hide FR EPDM VersiGard FR Nonreinforced WeatherBond RBR FR EPDM EPDM Non -reinforced Membrane Sure -Seal FleeceBACK PREMIUM - VersiFleece EPDM Membrane - Sure -Seal AFX - _ VersiFleece AC EPDM Membrane Sure -Tough Reinforced PREMIUM, C-EPDM-C, Mule -Hide Standard Versigard Reinforced WeatherBond RBR Standard STANDARD, C-EPDM-CR Reinforced EPDM EPDM Membrane Reinforced EPDM Membrane Sure -Tough FR C-EPDM-CR Type 1 Mule -Hide FR Reinforced Versigard FR Reinforced WeatherBond RBR FR Reinforced EPDM Reinforced EPDM Membrane Sure -White PREMIUM, EPDM RF - Mule -Hide White -on -Black Versigard Nonreinforced EPDM WeatherBond RBR White White EPDM -White EPDM Membrane Sure -White FleeceBACK Sure -Weld Reinforced TPO I White TPO Mule -Hide TPO-c Versiweld Reinforced TPO WeatherBond PRO TPO Membrane Membrane Sure -Weld HS - Mule -Hide TPO-c (FR) Versiweld ES - SAT-TPO - Mule -Hide SA-TPO Versiweld QA TPO WeatherBond PRO PAS TPO Sure -Weld _ Mule -Hide TPO-c Fleece VersiFleece TPO Membrane - FleeceBACK Back Sure -Weld AFX - Mule -Hide TPO-C Fleece VersiFleece AC TPO Membrane - Back Plus Spectro-Weld - - - - Spectro-Weld FleeceBack Sure -Flex - Mule -Hide PVC Membrane VersiFlex Reinforced PVC Membrane WeatherBond PRO PVC Sure -Flex KEE - - VersiFlex-E PVC Membrane - Sure -Flex FRS - Mule -Hide FRS PVC VersiFlex FRS Reinforced PVC Membrane Membrane Sure -Flex FleeceBack - - VersiFleece PVC Membrane - 90-8-30A Bonding 2001 Inc. Bonding Adhesive Mule -Hide Banding Adhesive G200SA Yellow Substrate WeatherBond RBR LC-60 Adhesive Adhesive Bonding Adhesive Solvent -Free EPDM _ - Solvent -Free EPDM Bonding Solvent -Free EPDM Bonding Bonding Adhesive Adhesive Adhesive Aqua Base 120 _ Mule -Hide WBBA-2000 Aqua Base 120 Bonding Aqua Base 120 Bonding Bonding Adhesive Bonding Adhesive Adhesive Adhesive Sure -Weld Bonding _ Mule -Hide TPO-c Bonding Versiweld Bonding Adhesive WeatherBond PRO TPO Adhesive Adhesive Bonding Adhesive Low VOC Bonding _ Mule -Hide Law VOC Bonding LOW VOC Bonding Adhesive LOW VOC Bonding Adhesive Adhesive Adhesive Law VOC Bonding Low VOC Bonding Adhesive Low VOC Banding Adhesive Adhesive 1168 _ 1168 1168 Sure -Flex Low VOC Mule -Hide Low VOC PVC VersiFlex Low VOC PVC WeatherBond Low VOC PVC PVC Bonding Adhesive _ Bonding Adhesive Bonding Adhesive Bonding Adhesive HydroBond PVC Water- HydroBond PVC Water -Based HydroBond PVC Water -Based Based Adhesive _ _ Adhesive Adhesive Cold Applied Adhesive - - Cold Applied Adhesive - FAST 100 Adhesive - Mule -Hide SP-100 Adhesive FAST 100 Adhesive - FAST 100 LV Adhesive - Mule -Hide SP-100-LT FAST 100 LV Adhesive - Adhesive OlyBond 500 Adhesive - - OlyBond 600 Adhesive OlyBond 500 Adhesive ESR-1463 ) Most Widely Accepted and Trusted Page 7 of 10 TABLE 2—FIRE CLASSIFICATION ASSEMBLIES —ADHERED ROOFING SYSTEMS2'6 SYSTEM ROOF DECK BARRIER BOARD INSULATION' MEMBRANEIMAX. ROOF SLOPE NO. CLASS OR SLIP SHEET Any of the following insulations, Sure -Weld, Spectro-Weld-'14:12 1-inch min. to 6-inch max. Sure -Seal, Sure -Tough, Sure -White, Sure - thickness: Carlisle "SecurShield Seal FleeceBACK, Sure -Weld HS, SAT-TPO, 1 A Noncombustible Polyiso", "Polyiso HP-H", Hunter Sure -Weld FleeceBACK, Spectro-Weld Panels "H-Shield" or FleeceBACK - /2:12 "H-Shield-CG" Sure -White FleeceBACK, Sure -Flex, Sure - Flex FRS - /4:12 '12-inch-thick fiberboard 4. '12-inch- Sure -White FleeceBACK-'/4:12 thick fiberboard or barrier board Sure -Seal, Sure -Tough - 1:12 (see Section 3.6) over 5-inch Sure -White, Sure -Seal FleeceBACK, Sure- ( A Noncombustible — max Insulfoam EPS , /2-inch- Weld, Spectro-Weld, Sure -Weld HS, SAT - thick fiberboard or barrier board TPO, Sure -Weld FleeceBACK, Spectro-Weld (see Section 3.6) over System FleeceBACK, Sure -Flex, Sure -Flex FRS - No. 1 insulations 1'/2:12 Sure -White FleeceBACK-'/4:12 Sure -White, Sure -Seal FleeceBACK - 1'/2:12 Noncombustible or Sure -Tough, Sure -Weld, Spectro-Weld, Sure- Combustible - min. 15132-inch-thick Barrier board Weld FleeceBACK, Spectra -Weld 3 A (see Section 3.6) _ FleeceBACK - 3,12 plywood or min. '!1s-inch-thick Sure -Weld HS, SAT-TPO - 4:12 OSB. Sure -Seal FR, Sure -Flex, Sure -Flex FRS — unlimited slope Any of the following insulations, Sure -Weld, Spectro-Weld-'/4:12 Combustible - min. Barrier board 1-inch min. Sure -Seal, Sure -Tough, Sure -White, Sure- 15132-inch-thick (see Section 3.6) or to 6-inch max. thickness: Seal FleeceBACK, Sure -Weld HIS, SAT-TPO, 4 A in. plywood or min. S sheet: 2layers Carlisle "SecurShield Polyiso", Polyiso HP-H", Sure -Weld FleeceBACK, Spectro-Weld FleeceBACK- /2:12 '/nch-thick see Section3.7) Hunter Panels "H-Shield" or Sure -White FleeceBACK, Sure -Flex, Sure- "H-Shield-CG" Flex FRS-'/4:12 Combustible - min. u/a2-inch-thick Any of the following insulations, Sure -Weld, S Sure -Weld 5 C _ 2-inch min. to 6-inch max. ex, Sure -Flex FRS — SAT-TPO, Sure -Flex, plywood or min. 7116-inch-thick thickness: Carlisle "Polyiso HP- unlimited slope OSB. H" or Hunter Panels "H-Shield" Single layer of minimum 3.0" or double layer of minimum 1.5" 6 A Combustible — Carlisle "SecurShield Polyiso" or EPDM, PVC, and TPO Membranes - %:12 Hunter Panels "H-Shield-CG" Single layer of minimum 1.9" 7 B Combustible _ Carlisle "SecurShield Polyiso" or EPDM, PVC, and TPO Membranes-'/2:12 Hunter Panels "H-Shield-CO" For SI: 1 inch = 25.4 mm. 'All foam plastic insulation must be UL-classified foamed plastic for roofing systems, and must be limited to the maximum thickness in accordance with Section 5.4 of this report or the maximum thickness in accordance with this table, whichever is less. 2See Section 3.10 for adhesive application rate. 'UL Classified EPS maybe installed below min. 1-inch-thick Carlisle or Hunter Panels polyisocyanu rate insulations (max slope 1:12) or below min.'/2-inch-thick Carlisle SecurShield HD or Hunter Panels H-Shield HD (max slope 2:12) on noncombustible decks. 4Carlisle SecurShield HD or Hunter Panels H-Shield HD may replace fiberboard and may be used as a coverboard over any insulation. When these two boards are used directly below the Sure -Weld membrane, the slope is limited to max. '/2:12. 6When these systems are used for reroofing or recovering, installation must be in accordance with Sections 4.2.2 and 5.7 of this report, and IBC Section 1510, IRC Section R907, BNBC Section 1512, SBC Section 1510 or UBC Appendix to Chapter 15, as applicable. ESR-1463 I Most Widely Accepted and Trusted Page B of 10 TABLE 3—FIRE CLASSIFICATION ASSEMBLIES —MECHANICALLY FASTENED ROOFING SYSTEMS° SYSTEM ROOF DECK BARRIER BOARD INSULATION ' MEMBRANE/MAX. ROOF NO. CLASS OR SLIP SHEET SLOPE Any of the following Insulations, 1-inch min. to Sure -Tough, Sure -Weld, 1 A — 6-inch max. thickness: Carlisle "SecurShield Spectro-Weld, Sure -Flex, Sure - Noncombustible Polyiso" or "Polyiso HP-H", Hunter Panels "H- Flex FRS-'/2:12 Sure HS 02:12 Shield" or"H-Shleld-C& -Weld - Sure -Tough FR-2:12 'I2-inch-thick fiberboard3,'/2-inch-thick Sure -Tough, Sure -Weld HS, fiberboard or barrier board (see Section 3.6) Sure -Flex, Sure -Flex FRS - 1:12 2 A Noncombustible — over 5-inch max Insulfoam EPS2,'/2-inch-thick Sure -Weld, Spectro-Weld - fiberboard or barrier board (see Section 3.6) 02:12 over System No. 1 insulations Sure -Tough FR - 3'/2:12 Sure -Weld, Spectro-Weld, Sure- 3 A Noncombustible — To 5-inch max: Insulfoam SP Weld HS, Sure -Flex, Sure -Flex FRS-'/2:12 Noncombustible or Sure -Tough, Sure -Weld, Combustible - min. Barrier board Spectro-Weld - 3:12 4 A 15112-inch-thick (see Section 3.6) — Sure -Tough FR - 3'/2:12 plywood or min. Sure -Weld HS, Sure -Flex, Sure- 'hs-inch-thick OSB. Flex FRS - unlimited Combustible - min. Barrier board Any of the following insulations, 1-inch min. Sure -Tough, Sure -Weld, is inch -thick (see Section 3.6) to 6-inch max. thickness: Carlisle Spectro-Weld, Sure -Flex, Sure- 5 A plywood or min. or Slip sheet: 2 "SecurShield Polyiso" or "Polyiso HP-H", Flex FRS-'/2:12 layers, Hunter Panels Sure -Weld HS, 1'/2:12 Its -inch -thick OSB. (see Section 3.7) "H-Shield" or "H-Shield-CG" Sure -Tough FR - 2:12 Combustible - min. Sure -Tough - 1:12 'slat -inch -thick Slip sheet, 2layers Sure -Tough FR, Sure Weld, 6 A plywood or min. (see Section 3.7) — Spectro-Weld, Sure -Weld HS, 'hs-inch-thick OSB Sure -Flex, Sure -Flex FRS - 1 /2:12 Combustible - min. Sure -Tough, Sure -Tough FR, 7 B 15/a2-inch-thick Slip sheet, 1 layer — Sure -Weld, Spectro-Weld, plywood or min. (see Section 3.7) Sure -Weld HS, Sure -Flex, Sure- '1,s-inch-thick OSB. Flex FRS - 02:12 Combustible - min. Any of the following insulations, 2-inch min. '6 !woodthick to 6-inch max. thickness: Carlisle Sure -Weld, Spectro-Weld, S C plywood omin. — "SecurShield Polyiso" or "Polyiso "H-Shield" Sure -Weld HS, Sure -Flex, Sure - !�s-inch-this k OSB. HP-H", Hunter Panels Flex FRS - unlimited or H-Shield CG" Single layer of minimum 3-inch or double layer 9 A Combustible — of minimum 1.5-inch Carlisle EPDM, PVC, and TPO "SecurShield Polyiso" or Membranes-'/2:12 Hunter Panels "H-Shield-CG" Single layer of minimum 1.9-inch Carlisle 10 B Combustible — "SecurShield Polyiso"or Hunter Panels EPDM, PVC, and TPO "H-Shield-CG" or single layer of an inverted Membranes - /2:12 G3 cap sheet. For SI: 1 inch = 25.4 mm. 'All foam plastic insulation must be UL-classified foamed plastic for roofing systems, and must be limited to the maximum thickness in accordance with Section 5.4 of this report or the maximum thickness in accordance with this table, whichever is less. 2UL Classified EPS may be installed below min. 1-inch-thick Carlisle or Hunter Panels polyisocyanurate insulations (max slope 1:12) or below min.'/ -inch -thick Carlisle SecurShield HD or Hunter Panels H-Shield HD (max slope 2:12) on noncombustible decks. 'Carlisle SecurShield HD or Hunter Panels H-Shield HD may replace fiberboard and may be used as a coverboard over any insulation. When these two boards are used directly below the Sure -Weld membrane, the slope is limited to'12:12. °When these systems are used for reroofing or recovering, installation must be in accordance with Sections 4.2.2 and 5.7 of this report, and IBC Section 1510, IRC Section R907, BNBC Section 1512, SBC Section 1510 or UBC Appendix to Chapter 15, as applicable. ESR-1463 I Most Widely Accepted and Trusted Page 9 of 10 TABLE 4—WIND RESISTANCE —MECHANICALLY FASTENED ASSEMBLIES°'' MAXIMUM MAXIMUM MAXIMUM SYSTEM ALLOWABLE DECK INSULATIONS MEMBRANE MEMBRANE FASTENER FASTENER NO. WIND UPLIFT FASTENING SPACING ROW (Psf) (inches) SPACINGS Foam plastic Insulation'''' 1 45 Noncombustible 1/2-inch-thick fiberboard' or Sure -Tough HP-X Fastener& 12 6ft6Inches barrier hoard Metal Fastening Bar (See Sect. 3.6) 2 75 Noncombustible Same as System No. 1 Sure -Tough HP-X Fastener & 6 6 ft 6 inches Metal Fastening Bar 3 52 Noncombustible Same as System No. 1 Sure -Tough HP Fastener & 6 9 ft 6 inches Polymer Seam Plate 4 45 Noncombustible Same as System No. 1 Sure -Tough Sure-Tite Fastener& 12 9 ft 6 inches ST Fastening Bar 5 30 Noncombustible Same as System No. 1 Sure -Tough HP Fastener & 12 9 fit 6 inches (75 mil) Polymer Seam Plate 6 60 Noncombustible Same as System No. 1 Sure -Tough HP Fastener & 6 9 ft 6 inches (75 mil) Polymer Seam Plate -Weld or Sure -Weld or HP-X or HP-Xtra 7 45 Noncombustible Same as System No. 1 Sure Fasteners with Piranha 12 7 fi 6 inches or Piranha Xtra Plates 8 45 Noncombustible Same as System No. 1 Sure -Weld or HP-Xtra Fasteners with 12 9 ft 6 inches Spectra -Weld Piranha Xtra Plates HP-X or HP-Xtra 9 60 Noncombustible Same as System No. 1 Sure -Weld or Fasteners with 6 9 ft 6 inches Spectre -Weld Piranha or Piranha Xtra Plates Sure -Weld or -Weld or HP-X or HP-Xtra 10 67 Noncombustible Same as System No. 1 Sure Fasteners with Piranha 6 7 ft 6 Inches or Piranha Xtra Plates Sure -Weld or HP-X or HP-Xtra 11 30 Noncombustible Same as System No. 1 Spectro-Weld Fasteners with Piranha 12 11 ft 6 inches or Piranha Xtra Plates Sure -Weld or HP-X or HP-Xtra 12 60 Noncombustible Same as System No. 1 Spectro-Weld Fasteners with Piranha 6 11 ft 6 inches or Piranha Xtra Plates 13 53 Noncombustible Same as System No. 1 Sure -Flex HP-X Fasteners with 6 6 ft 4 inches Piranha Plates 14 83 Noncombustible Same as System No. 1 Sure -Flex HP-X Fasteners with Piranha Plates 6 2 ft 11 inches HP-X or HP-Xtra 15 30 Noncombustible Same as System No. 1 Sure -Flex Fasteners with Piranha 18 6 ft 4 inches or Piranha Xtra Plates HP-X or HP-Xtra 16 45 Noncombustible Same as System No. 1 Sure -Flex Fasteners with Piranha 12 6 ft 4 inches or Piranha Xtra Plates 17 53 Noncombustible Same as System No. 1 Sure -Flex HP-X Fasteners with 12 2 ft 11 inches Piranha Plates 18 45 Noncombustible Same as System No. 1 Sure -Weld HP-X Fasteners with 1 per 5.3 ft' NIA OMG RhlnoBond Plates 19 60 Noncombustible Same as System No. 1 Sure -Weld HP-X Fasteners with 1 per 4 ft2 N/A OMG RhinoBond Plates For SI: 1 inch = 25.4 mm; 1 ft = 0.305 m; 1 psf = 47.88 Pa. 'Foam plastic insulation must be any of the following (1-inch min. to 6-inch max. thickness): Carlisle "SecurShield Polyiso","Polyiso HP-H" Hunter Panels "H-Shield" or Hunter Panels "H-Shield- CG". 2AII foam plastic insulation must be UL-classified foamed plastic for roofing systems, and must be limited to the maximum thickness in accordance with Section 5.4 of this report or the maximum thickness in accordance with this table, whichever is less. 'Steel deck must be minimum No. 22 gage galvanized steel [base -metal thickness 0.030 inch (0.76 mm)]. Concrete must have a minimum compressive strength (f'') of 2500 psi. See Section 5.6 of this report. 4For existing metal roofing, the assemblies listed must he installed by fastening through the roofing and into structural members (puffins, angle iron, beams, etc.) capable of resisting all expected loads. The maximum allowable wind uplift (field) pressures are shown in Column 2. SUL Classified EPS may be installed below min. 1-inch-thick Carlisle or Hunter Panels pofyisocyanumte insulations (max slopel:12) or below min. '12-inch- thick Carlisle SecurShield HD or Hunter Panels H-Shield HD (max slope 2:12) on noncombustible decks. 'Carlisle SecurShield HD or Hunter Panels H-Shield HD may replace fiberboard and may be used as a coverboard over any Insulation. When these two boards are used directly below the Sure -Weld membrane, the slope is limited to'/2:12. 7 When these systems are used for reroofing or recovering, installation must be in accordance with Sections 4.2.2 and 5.7 of this report, and IBC Section 1510, IRC Section R907, BNBC Section 1512, SBC Section 1510 or UBC Appendix to Chapter 15, as applicable. ' Fastener raw spaces shown are for field of roof only. See Section 4.3 for recognized fascia systems for mechanically fastened roof assemblies. The maximum allowable load for Carlisle SecurEdge 300 is 234 plf (348 kg/m). The maximum allowable load for Carlisle SecurEdge 3000 is 200 off (298 kg/m). Distance between the edge of the roof and the first row of fasteners must be determined accordingly. ESR-1463 Most Widely Accepted and Trusted I Page 10 of 10 TABLE 5—WIND RESISTANCE —ADHERED ASSEMBLIES' SYSTEM ALLOWABLE INSULATION MEMBRANE NO. WIND UPLIFT DECK INSULATION / MIN. THICKNESS1'3 FASTENING TYPE (FIELD) (psf) RATE 1 45 Combustible or '/2 inch fiberboard 4, "/32 inch OSB, or barrier board 1 per 2 ft2 EPDM, PVC and TPO Noncombustible (See Section 3.6) Membranes 45 Combustible or Carlisle "Polyiso HP-H" or "SecurShield Polyiso"; Hunter Panels "H-Shield" "H-Shield-CG" / 1.4 inch 1 3.2 ft 2 EPDM, PVC and TPO 2 Noncombustible or per Membranes with /2-inch Securack coverboard (optional) Combustible or Carlisle "Polyiso HP-H" or "SecurShield Polyiso'; Hunter Panels "H-Shield" "H-Shield-CG" / 2.0 inch 1 4 ft 2 EPDM, PVC and TPO 3 45 Noncombustible or per Membranes with /s-inch Securack coverboard (optional) 4 68 Combustible or Carlisle "Polyiso HP-H" or "SecurShield Polyiso"; FAST Adhesive FleeceBACK Membranes Noncombustible Hunter Panels "H-Shield" or "H-Shield-CG" / 1.0 inch Combustible or Carlisle "Polyiso HP-H" or "SecurShield Polyiso'; Hunter Panels "H-Shield" "H-Shield-CG" / 2.0 inch 2 1 1.6 ft EPDM, PVC and TPO 5 75 Noncombustible or with 12-inch Securack coverboard (optional) per Membranes TPO Membranes; 6 120 Combustible or Carlisle "Polyiso HP-H" or "SecurShield Polyiso'; 1 per 1 ft 2 EPDM membranes Noncombustible Hunter Panels "H-Shield" or "H-Shield-CG" / 2.0 inch (with noncombustible deck only) Combustible or Carlisle "Polyiso HP-H" or "SecurShield Polyiso'; Hunter Panels "H-Shield" "H-Shield-CG" / 2.0 inch 2 1 1 ft EPDM and TPO 7 128 Noncombustible or per Membranes with /2-inch Securock coverboard (optional) 135 Combustible or Carlisle "Polyiso HP-H" or "SecurShield Polyiso"; Hunter Panels "H-Shield" "H-Shield-CG" / 2.0 inch 1 1 ft 2 FleeceBACK Membranes 8 Noncombustible or per with /2-inch Securock coverboard (optional) 9 143 Combustible or '/z inch DensDeck Prime 1 per 1 ft' FleeceBACK Membranes Noncombustible For SI: 1 inch = 25.4 mm; 1 ft = 0.305 m; 1 psf = 47.88 Pa 'All foam plastic insulation must be UL-classified foamed plastic for roofing systems, and must be limited to the maximum thickness in accordance with Section 5.4 of this report or the maximum thickness in accordance with this table, whichever is less. Steel deck must be minimum No. 22 gage galvanized steel [base -metal thickness 0.030 inch (0.76 mm)]. Concrete must have a minimum compressive strength (f".) of 2500 psi. See Section 5.6 of this report, 3UL Classified EPS may be installed below min. 1-inch-thick Carlisle or Hunter Panels polyisocyanurate insulations (max slope 1:12) or below min.'/2-inch-thick Carlisle SecurShield HD or Hunter Panels H-Shield HD (max slope 2:12) on noncombustible decks. "Carlisle SecurShield HD or Hunter Panels H-Shield HD may replace fiberboard and may be used as a coverboard over any insulation. When these two boards are used directly below the Sure -Weld membrane, the slope is limited to'l2:12. 'When application is over existing roofs, documentation of the wind -uplift resistance of the composite roof construction must be submitted to the code official for approval at the time of permit application. For reroofing or recovering, installation must be in accordance with IBC Section 1510, IRC Section R907, BNBC Section 1512, SBC Section 1510 or UBC Appendix to Chapter 15, as applicable.