B-2016-1344 REV#1 PLANSDC PV Size: 3.64 KW Azimuth : 280 /110 deg. Number of PV Modules: 14 PV model: SW 260 Module Dim: 64.5" x 38.7" Module Weight: 39.5 lbs. Panel area: 17.33 sq. ft. INVERTER Enphase M215 :14 Racking System Everest Roof Type: Pitch Shingle Trust/Rafter spacing: 24" OX Framing: 2" x 4" Roof: 14 panels Penetration Max: 72" PV Area: 242 sq. ft. Mounting hardware weight: 91 lbs Total panel weight. 553 lbs. Entire weight on roof: 644 lbs. 644 Ibs/242 sq. ft.= 2.66 lbs/sq. ft. iENT :ns P LANS CHECKED BY DATE PLANNING DEPT CUPERTINO Roof Mount Solar Array Project Description 1. Monitoring system with inverter 2. No battery back-up systems 3. Standard Components include: racking and mounting components, wiring, conduit, and over -current protections 4. All supplied equipment is UL listed. 5. Equipment to be installed per listing or labeling and NEC and CEC 690 requirements. 6. All Metal parts of module frames, equipment, and conductor enclosures will be groui@lR��� 7. All outdoor wiring will be weather rated. �ing Uepallm Z 8. Electrical Main Panel, inverter(s) and controller panels will be I warning a S. REVIE�NEC 'rumModule wed 9Y O << fire access!jv e� O junction box sub panel Main Service Panel to-,rLek Inverter FQeA << fire access >> r PLAN 5809 MISSION ST. SAN FRANCISCO CA,94112MM/DD/ri -624 3535STTE 415 LIC# 962034 REVISIONS MARKS a os 1G 6 amt RRVI&ION Elias & Ruth Zabor 22918 Cricket hill dr Cupertino CA 95014 408-44 - 2 4 5 17 P ® EQUIPMENT DESCRIPTION TAG DESCRIPTION PART NUMBER NOTES 1 PV DC MODULE SW 260 mono 260 W MODULE QUANTITY-14 2 DC/AC INVERTER M215-60-2LL•S25-IG En hase M215 uant! - 14 3 A/C disconnect SQUARED 30 AMP NON FUSED DISCONNECT 4 PV ARRAY N/A i Str/n of 14 Modules 5 SERVICE PANEL Squre D existing 100 125A Buss Rating 6 Sub Pane! ® CONDUIT AND CONDUCTOR SCHEDULE TAG DESCRIPTION OR CONDUCTOR TYPE COND. GAUGE # OF CONDUCTORS CONDUIT TYPE CONDUIT SIZE Y Module cable MFG MFG CABLE N/A N/A 2 EQUIPMENT GROUND 8 AWG Y BARE COPPER N/A N/A 3 PV wire i0 AWG MFG CABLE N/A free air 4 THWN-2 YpAWG Y-B,1-R,1-W T-G EMT 1/2" 5 6 14 modules MO 1 2P, 20A 6kr UTILITY METER *Installed opposite from main �,/ 1 M ioo am &eaker (existing) D 4 AC 3 Juntion Etu/� 'IV roof n ,ty „5 I / Id n.4 L)B 7fy>n �R I EVI/ES � Review co�F z S11 6 <Ip/WC S All metal part of module frames, equipment, and conductor = UILDING enclosures will be grounded. GROUNDING per NEC and CEC 690 requirements ELECTRODE REVISION ' ONE LINE DIAGRAM 5809 MISSION ST. SAN FRANCISCO CA,94112 415-624-3535 LIC# 962034 REVISIONS Mn/nnm, aea�nxxs Elias &Ruth Zabor 22918 Cricket hill dr Cupertino CA 95014 408-446-3208 5 Panel Mfg Model Solarworld SW 260 Vmp 30.7 V Imp 8.56 A Voc 38.9 v Ise 9.18 A Pmax 260 W Length(in) 65.94 Width(in) 39.41 Weight(lbs) 46.7.9 Inverter Mfg Model Enphase M215-60-2LL-S25-IG Input Data Max DC Voltage 48 V Peak Power Voltage 27-39 V DC Max Input Current 10 A Output Data AC Max Output Power 215 W AC Max Output Current 0.9 A AC Norminal Voltage Range 240 V System Specification DC Side(Local to each Individual Inverter & Module Pair) Operating Current 10 A Operating Voltage 27-39V Maximum System Voltage 46 V Short Circuit Current Ise 9.58 A AC Wire Sizing Calculations Branch 1 Inverter Adjusted Max NEC Rated Ambient Temperature Number of of Derate Max Run percent Max AC Current Ampacity Temperature Derate Conductors Conductor in Conduit Wire Feet Voltage Current Safety por CEC THWN-2 Celsius Factor per Conduit Derate Ampacity Drop Amp Factor 890.8 AMP 410 90c Factor AMP 12.6 A 1.25 15.75 40 61-70 0.58 4-6 0.8 18.56 1 50 1 0.264 Labeling: All warning signs shall be red background with 1 1/2" white lettering, all capital letters, Aerial or similar, non -bold. Material used for signage must be weather resistant. Labels on raceways and other equipment shall be reflective, weather resistant, and suitable for the environment. Premises having PV ststems shall be identified, the marking(signage) may be placed within the main service disconnect. If the main service diconnect is operable with the service panel closed, the markings should be placed on the outside cover. Marking shall conform to the folowing: (State Fire Marshal) Marking is required on all interior and exterior DC Condiot, raceways, enclosures, cable assemblies, andjunction boxes to alert the Fire Service to avoid cutting them, every 10 feet, at turns and above/or below penetrations and all DC combiner and Junction Boxes. Appropriate signage shall be provided to identify the main A/C disconnect for gjr�s ,�t�py (State Fire Marshal) �Uot1 I �lyt„d wilding Department CE C wires from panels are connected via manufacturer's specs. o field installed DC wiring or connectors. Wiring Size Check Adjusted Inverter Imp = 1.25 * 12.6A= 15.75 A< (40A*0.58*0.8)=18.58A #12THWN-2 OK iker 1 at AC Load Center: 9A* 14 Inverters = 12.6 A* 1.25=15.75 A Use 20A Total Solar: 0.9A* 14 Inverters= 12.6A *1.25 Safety Factor-- 15.75 A Where all the terrain a warring sign shall WARNING - -. _ELECTRiCSI-IOCK HAZARD DO NOT 1"OUCH TERMINALS t 'I'ERMlNA1.S ON BOTH THE LINE AND F" LOAD SIDES MAY I3E-ENERGIZED _ IN TI Ili OPEN POSITION SOLARBREAKERi Calcuations and Safety Labels e AU In .1; 5809 MISSION ST. SAN FRANCISCO CA,94112 `..: 415-624-3535-- ___ _ Lic# 962034 REVISION�s�� Mm onlvx_ a Elias &Ruth Zabor 22918 Cricket hill dr Cupertino CA 95014 40 - 46-3208 4 5