15080125CITY OF CUPERTINO BUILDING PERMIT
BUH.DINGADDRESS:
CONTRACTOR:
PERMIT NO: 15080125
10676 CARVER DR CUPERTINO CA 95014 (375 32 015)
T Q CONSTRUCTION
OWNER'S NAME: LI GERALD CHIA-GENE AND LIDIA SHIU-
DATE ISSUED: 11/10/2015
OWNER'S PHONE: 408-239-7888
PHONE NO: 408-849-1715
L ICENSED CONTRACTOR'S DECLARATION
BUILDING PERMIT INFO:
License Class B LN #
Contractor T Q CONSTRUCTION Date 02/23/2016
—BLDG —ELECT _ PLUMB
RESIDENTIAL COMMERCIAL
MECH
I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing
_
with Section 7000) of Division 3 of the Business & Professions Code and that my
license is in full force and effect.
JOB DESCRIPTION:
CONSTRUCT NEW 1 STORY SFD (2400 S.F.), FRONT PORCH
I hereby affirm under penalty of perjury one of'the following two declarations:
(78 S.F.) WITH ATTACHED GARAGE (432 S.F.)
1. I have and will maintain a certificate of consent to self-insure for Worker's
bEF # 1 - TRUSS SYSTEM CALCS - ISSUED 2/23/16
Compensation, as provided for by Section 3700 of the Labor Code, for the
!performance of the work for which this permit is issued.
I have and will maintain Worker's Compensation Insurance, as provided for
by Section 3700 of the Labor Code, for the performance of the work for which
5q. Ft Floor Arca:
Valuation: $336000.00
this permit is issued.
APPLICANT CERTIFICATION
certify that I have read this application and state that the above
information is correct. I agree to comply with all city and county
APN Number:
Occupancy Type:
ordinances and state laws relating to building construction, and hereby
375 32 015
authorize representatives of this city to enter upon the above mentioned
property for inspection purposes. (We) agree to save indemnify and keep
harmless the City of Cupertino against liabilities, judgments, costs, and
PERMIT EXPIRES IF WORK IS NOT STARTED
expenses which may accrue against said City in consequence of the
WITHIN 180 DAYS OF PERMIT ISSUANCE OR
granting of this permit. Additionally, the applicant understands and will
comply with all non-point source regulations per the Cupertino Municipal
180 DAYS FRO AST ,
Code, Section 9.18.
Issued by: MELIS A
Signature:- Date 02/23/2016
Date: 02/23/2016
OWNER-BUILDER DECLARATION
RE-ROOFS:
I hereby affirm that I am exempt from the Contractor's License Law for one of the
All roofs shall be inspected prior to any roofing material being installed. If a roof is
following two reasons:
installed without fust obtaining an inspection, I agree to remove all new materials for
1. I, as owner of the property, or my employees with wages as their sole
inspection.
compensation, will do the work, and the structure is not intended or offered
for sale (Sec.7044, Business & Professions Code)
Signature ofApplicant
z. I, as owner of the property, am exclusively contracting with licensed
Date: 02/23/2016
contractors to construct the project (Sec.7044, Business & Professions Code).
ALLROOF COVERINGS TO BE CLASS "A" OR BETTER
I hereby affirm under penalty of perjury one of the following three declarations:
1. I have and will maintain a Certificate of Consent to self-insure for Worker's
Compensation, as provided for by Section 3700 of the Labor Code, for the
HAZARDOUS MATERIALS DISCLOSURE
performance of the work for which this permit is issued.
I have read the hazardous materials requirements under Chapter 6.95 of the
2. I have and will maintain Worker's Compensation Insurance, as provided for
California Health & Safety Code, Sections 25505, 25533, and 25534. I will
by Section 3700 of the Labor Code, for the performance of the work for which
maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the
Health & Safety Code, Section 25532(a) should I store or handle hazardous
this permit is issued.
3. I certify that in the performance of the work for which this permit is issued, I
material. Additionally, should I use equipment or devices which emit hazardous
air contaminants as defined by the Bay Area Air Quality Management District I
shall not employ any person in any manner so as to become subject to the
will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and
Worker's Compensation laws of California. If, after making this certificate of
the Health & Safety Code, Sections 25505, 25533, and 25534.
exemption, I become subject to the Worker's Compensation provisions of the
Labor Code, I must forthwith comply with such provisions or this permit shall
Ole/
Owner or authorized age t O `f
be deemed revoked.
Date: 02/23/2016
APPLICANT CERTIFICATION
I certify that t have read this application and state that the above information is
CONSTRUCTIO LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance
correct. I agree to comply with all city and county ordinances and state laws
of work's for which this permit is issued (Sec. 3097, Civ C.)
relating to building construction, and hereby authorize representatives of this city
Lender's Name
to enter upon the above mentioned property for inspection purposes. (We) agree
Lender's Address
to save indemnify and keep harmless the City of Cupertino against liabilities,
judgments, costs, and expenses which may accrue against said City in
ARCHITECT'S DECLARATION
consequence of the granting of this permit. Additionally, the applicant
I understand my plans shall be used as public records.
understands and will comply with all non-point source regulations per the
Cupertino Municipal Code, Section 9.18.
Licensed
Professional
Signature Date 02/23/2016
._................_.__......__..
CONSTRUCTION PERMIT APPLICATION
COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISI N
10300 TORRE AVENUE • CUPERTINO, CA 95014-3255
CUPERTINO (408) 777-3228 • FAX (408) 777-3333 • buildina(C)CUDerlino.ora
❑' NEW COI�TSTRUCTION ❑ ADDITION ❑ ALTERATION / TI REVISO DEFERRED MGINAL PERMIT 4
&eoio5-
PROJECT ADDRESS 106'7G C 49%46T, ®PZ
a
APN
OWNERNAME�.�/ h9 /p�� PHOyry
E-MAIL
STREET ADDRESS CITY, STATE, ZIP FAX
CONTACT NAME �.�®�
PHONE E-MAIL
STREET ADDRESS �� C�'-1 Kew J/ !
CITY, STATE, ZIP
FAX
OWNER 11 OWNER -BUILDER ❑ OWNERAGENT CONTRACTOR ❑: CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER '❑ TENANT
CONTRACTOR NAME
LICENSE NUMBER
LICENSE TYPE
BUS. LIC #
►
COMPANY NAME e
E-MAIL i
FAX
STREET ADDRESS 6f���`� j✓�Z.
CITY, STATE, ZIP
PHONE f
r-�
ARCHITECTIENGINTEER NAM
LICENSE NUMBER
BUS. LIC #
COMPANY NAME
E-MAIL
FAX
STREET ADDRESS
CITY, STATE, ZIP
PHONE
DESCRIPTION OF WORK
EXISTING USE
PROPOSED USE - CONSTR.
TYPE # STORIES.
USE TYPE OCC.
SQ.FT.
VALtiATION (S)
EXISTG
NEW FLOOR
DEMO
TOTAL
AREA
AREA.
AREA
NETAREA
BATHROOM
KITCHEN -
.OTHER - -
REMODEL AREA
I
REMODEL AREA
REMODEL.AREA
PORCH AREA
DECK AREA
DECKIPORCH AREA
GARAGE AREA: DETACH -
7TOTAL
ATTACH
# DWELLING UNITS:
IS A SECOND UNrr [J YES
SECOND STORY F1 YES
TBELNGADDEDI []NO
ADDITION? E]NO
PRE -APPLICATION ❑ YES IF YES, PROVIDE COPY OF
IS THE BLDG AN ❑FES - y xa„ , ,_
T L YATUATION:
PLANNING APPL # ❑ NO PLANNING APPROVAL LETTER
EICHLER HOA4E? N R�-„h
By my signature below, I certify to each of the following: I am the property owner or athoriz afire on the property owner's behalf. I have read this
application and the information I have provided is correct. I have read the Description o and perify it is accurate. I agree to comply with all applicable local
ordinances and state laws relating to building construction. I authorize representatives of Cupertino to enter the above -identified property, for inspection purposes.
Signature of Applicant/Agent: Date:
01 6V
SUPPLEMENTAL FO ION REQUIRED
t TI
4` r
ROUTII\G SLIP
rii. CHECK PE
«�,4,
rHE COII\TER
BUILDI\G PLA REW IEW4' 3ls
New SFD or Multifamilydwellings: Apply for demolition for
ppy on permit
existing building(s). Demolition permit is required prior to issuance of building�y
e
permit for new building.
I-7 x EXPREss q
PLAN \ING P AIv iiE� IES§' Y
�s
Commercial Bldgs: Provide a completed Hazardous Materials Disclosure
rA vDnitD
❑ PusLlC tvoRl�s, , 5
_
form if an Hazardous Materials are bein used as pat of this project.
y P P
I� pz
FIREDEPT z
Copy of Planning Approval Letter or Meeting With Planning prior to
1ARGE
� �
_
submittal of Building Permit application.
L7 NLA.IOR
a
S�'�ITARaSEti3ERDISTRiCT�
1]R E\VIROINMENTAi HEALTH XN
BldgApp_2011.doc revised 06/31111
II
CITY OF CUPERTINO BUILDING PERMIT
BUILDING ADDRESS: 10676 CARVER DR
CONTRACTOR: TQ CONSTRUCTION PERMIT NO: 15080125
OWNER'S NAME: GERALD LI
3044 KENTRIDGE DR DATE ISSUED: 11/10/2015
O R'S PHONE: 4082397888
SAN JOSE, CA 95133 PHONE NO: (408) 849-1715
LICENSED CONTRACTOR'S DECLARATION
JOB DESCRIPTION: DESCRIPTION: RESIDENTIAL COMMERCIAL
License Class I`J Lic. # �
I`) V-)
CONSTRUCT NEW 1 STORY SFD (2400 S.F.), FRONT PORCH (78 S.F.) WITH
_-
v
ATTACHED GARAGE (432 S.F.)
Contractor 1_. ate_�-
I hereby affirm that I am licensed under the provisions of Lhap4r 9
(commencing with Section 7000) of Division 3 of the, Business & Professions
Code and that.my license is in full force and effect.
I hereby affirm under penalty of perjury one of the following two declarations:
I have and will maintain a certificate of consent to self -insure for Worker's
Compensation, as provided for by Section 3700 of the Labor Code, for the
Sq. Ft Floor Area:
Valuation: $336000
p rformance of the work for which this permit is issued.
have and will maintain Worker's Compensation Insurance, as provided for by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued.
APN Number: 37532015.00
Occupancy Type:.
APPLICANT CERTIFICATION
I certify that I have read this application and state that the above information is
PERMIT EXPIRES IF WORK IS NOT STARTED
correct. I agree to comply with all city and county ordinances and state laws relating
to building construction, and hereby authorize representatives of this city to enter
WITHIN 180 DAYS OF PERMIT ISSUANCE OR
upon the above mentioned property for inspection purposes. (We) agree to save
180 DAYS FROM LAST CALLED INSPECTION.
indemnify and keep,harmless the City of Cupertino against liabilities, judgments,
costs, and expenses which may accrue against said.City in consequence of the
b
granting of this permit. Additionally, the applicant understands and will comply
Issued by: K "" Date: t t
with all non -point source regulations per the Cupertino Municipal Code, Section
9.18.
RE -ROOFS:
Signature Date
All roofs shall he inspected prior to any roofing material being installed. If a roof is
installed without first obtaining an inspection, I agree to remove all new materials for
inspection.
OWNER -BUILDER DECLARATION
Signature of Applicant: Date:
I hereby affirm that I am exempt from the Contractor's License Law for one of
the following two reasons:
ALL ROOF COVERINGS TO BE CLASS "A" OR R BETTER
I, as owner of the property, or my employees with wages as their sole compensation,
will do the work, and the structure is not intended or offered for sale (Sec.7044,
Business & Professions Code)
I, as owner of the property, am exclusively contracting with licensed contractors to
HAZARDOUS MATERIALS DISCLOSURE
construct the project (Sec.7044, Business & Professions Code).
I have read the hazardous materials requirements under Chapter 6.95 of the
California Health & Safety Code, Sections 25505, 25533, and 25534. I will
I hereby affirm under penalty of perjury one of the following three
maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the
declarationsc
Health & Safety Code, Section 25532(a) should I store or handle hazardous
I have and will maintain a Certificate of Consent to self -insure for Worker's
material. Additionally, should I use equipment or devices which emit hazardous
Compensation, as provided for by Section 3700 of the Labor Code, for the
air contaminants as defined by the Bay Area Air Quality Management District I
performance of the work for which this permit is issued.
will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and
I have and will maintain Worker's Compensation Insurance, as provided for by
the Health & Safety Code, Sections 25505, 25533, and 25534.
Section 3700 of the Labor Code, for the performance of the work for which this'
Owner or authorized agent :I Date.__-ft1
permit is issued.
/
I certify that in the performance of the work for which this permit is issued, I shall
not employ any person in any manner so as to become subject to the Worker's
Compensation laws of California. If, after making this certificate of exemption, I
CONSTRUCTION LENDING AGENCY
become subject to the Worker's Compensation provisions of the Labor Code, I must
I hereby affirm that there is a construction lending agency for the performance of
forthwith complywith such provisions or this permit shall be deemed revoked.
work's for which this permit is issued (Sec. 3097, Civ C.)
Lender's Name
APPLICANT CERTIFICATION
Lender's Address
I certify that I have read this application and state that the above information is
correct. I agree to comply with all city and county ordinances and state laws relating
to building construction, and hereby authorize representatives of this city to enter
upon the above mentioned, property for inspection purposes. (We) agree to save
ARCHITECT'S DECLARATION
indemnify and keep harmless the City of Cupertino against liabilities, judgments,
costs, and: expenses which may accrue against said City in consequence of the
I understand my plans shall be used as public records.
granting of this permit. Additionally, the applicant understands and will comply
with all non -point source regulations per the Cupertino Municipal Code, Section
Licensed Professional
9.18.
Signature Date
CITY OF CUPERTINO -45ceoloro
FEF. F,STTMATOR R1T1T,D1N(i' nTVlglnN
a > ADDRESS: 10676 CARVER DR.
FEE
DATE: 08/17/2015
REVIEWED BY: PAUL
APN: 375 32 015 1BP#:
$3,067.05
Select a Misc Bldg/Structure
or Element of a Building
*VALUATION: 1$336,000
*PERMIT TYPE: Building Permit
PLAN CHECK TYPE: New Construction
PRIMARY SFD or Duplex
USE:
2nd Unit? Yes '° No
PENTAMATION 1 R3SFDW
PERMIT TYPE:
WORK
[Construct New 1 Story SFD 2400 S.F.),Front
Porch 78 S.F. with Attached Garage 432 S.F.
SCOPE
0.0
hrs
OCCUPANCY TYPE: TYPE OF FLR AREA PC FEES PC FEE ID BP FEES BP FEE ID
CONSTR. s.f.
R-3 (Custom) II-B,111-6,IV,V-B 2,910 $3,067.05 IR3PLNCK $3,012.15 IR3INSP
I TOTALS: I 2,910 I $3,067.05 $3,012.15 ( y'
1:1>c/t. 111an Check Plumb. Plan Giecic I"lec. Plan Check
F114ech, Permit bee: Plurab. Perfnif.Fee: -Ile. Permit Fee:
Other-ltech.Insp. Other Plurttla1rup. Olhet�Eleec Insp.
F7 -1 -
MIA Jiup..fee,- Plumb. Trap. /Fisc • Elea Insp. Fee:
NOTE: This estimate does not include fees due to other Departments (t.e. Planninz Public Works, Fire, Sanitary Sewer District, School
District, etc.). These_fees are based on the preliminary information available and are only an estimate. Contact the Dept.for addn'l into.
FEE ITEMS (Fee Resolution 11-053 Eff. 7/1/13,)
FEE
QTY/FEE
MISC ITEMS
Plan Check Fee:.
$3,067.05
Select a Misc Bldg/Structure
or Element of a Building
Suppl. PC Fee: Reg. 0 OT
O.p
hrs
$0.00
PME Plan Check:
$0.00
Permit Fee:
$3,012.15
Suppl. Insp. Feer Reg. OOT
0.0
hrs
$0.00
PME Unit Fee:
$0.00
PME Permit Fee:
$0.00
,
Construction Tax: 1BCONSTAXRF,
I # new
units
$684.98
41ininis fttlive l''ee:
Work Without Permit? 0 Yes (F) No
$0.00
Advanced Planning Fee: IPLLONGR$407.40
Select a Non -Residential E)
Building or Structure 0
Travel Docu neniai'ion 1-ees:
Strong Motion Fee: IBSEISMICR
$43.68
Select an Administrative Item
Bldg Stds Commission Fee: IBCBSC
$14.00
SLJBTOTAi.S:= $7,229.26 $0.00 TOTAL i+E $7,229.26
Revised: 07/02/2015
Building Department
City Of Cupertino
10300 Torre Avenue
Cupertno,-CA 95014-3255
Telephone: 408-777-3228
C U F' E RTrN 0' Fax: 408-777-3333
CONTRACTOR > SUBCONTRACTOR LIST
JOB'ADDRESS-.PERMIT # 1
OWI�]ER.' S` NAME: PHONE # t
GENERAL CONTRACTOR; �' S— BUSINESS LICENSE
ADDRESSc p ay4MTY/ZIPCODE:
_..
*Our municpaLcode requires all b messes workin the city to have a City of -Cupertino business license.
NO BUILDING FINAL OR FINAL OCCUPANCY INSPECTIONS) WILL BE SCHEDULED UNTIL THE
GENERAL CONTRACTOR, AND ALL SUBCONTRACTORS HAVE OBTAINED A CITY OF CUPERTINO
BUSINESS LICENSE.
I am not using any subcontractors: _ - > ;
e Dat
Please check applicable subcontractors and complete the following information:
SUBCONTRACTOR BUSINESS NAME BUSINESS LICENSE #
Cabinets & Millwork -
Cement Finishing
Electrical
Excavation
Fencing
Flooring / Carpeting
Linoleum Wood
Glass / Glazing
He' ating
Insulatio
Landscaping
Lathing _
Masonry
Painting / Wallpaper
Paving
Plastering.
Plumbing
Roofing
Septic Tank
Sheet Metal
Sheet Rock
Tile
Owner / Contractor Signature
Date
CERTIFICATE OF VERIFICATION CF31R-MCH-20ml-!
Duct Leakage Diagnostic Test (Page 1 of 3
Project Name: Mike Vo
Enforcement Agency: City of
Cupertino
Permit Number:
Dwelling Address: 10676
City: CAAVEP, Piz Cupertino
Zip Code: 95014
A. System Information
01
Space Conditioning System Identification or Name
System one
02
Space Conditioning System Location or Area Served
Whole House
03
Building Type from CF -IR
Single family
04
Verified Low Leakage Ducts in Conditioned Space
(VLLDCS) Credit from CFIR?
No, credit is not taken
05
Verified Low LeakageAir Handling Unit (VLLAH U) Credit
from CF1R?
No, credit is not taken
06
Duct System Compliance Category.
New
IVICH-20a - Completely Ne �PL S yst e
R
B. Duct Leakage Diagnostic Test P
01
Condenser Nominal Cooling Capacity (ton)
0
02
Heating Capacity (kBtu/h)
78
03
Conditioned Floor Area served by this HVAC system (ft2)
2400
04
Duct Leakage Test Condition
Test final
05
Duct Leakage Test Method
Total leakage
06
Leakage Factor
0.06
07
Air Handling Unit Airflow (AHUAirflow) Determination
Method
Heating system method
08
Measured AHUAirflow
This field or section is not applicable
09
Calculated Target Allowable Duct Leakage (cfm)
102
10
Actual duct leakage rate from leakage test measurement
(cfm)
98
I
11
Compliance Statement
I System passes leakage test
Registration Number: 216-A038301OA-M2000001A-M20A Registration Date/Time: 2016-10-12 15:19:21 HERS Provider: CalCERTS
CA Building Energy Efficiency Standards Report Version: 2013 Rev 1.008 Report Generated: 2016-10-12 15:15:39
2013 Residential Compliance Schema Version: 2013.1.007
CERTIFICATE OF VERIFICATION CF3R-MCH-20-H
Duct Leakage Diagnostic Test (Page 2 of 3)
B. Duct Leakage Diagnostic Test
12 Notes
C. Additional Requirements for Compliance
01
System was tested in its normal operation condition. No temporary taping allowed.
Outside air (OA) duct connections to the central forced air duct system shall not be sealed/taped off during duct leakage
02
testing. OA ducts used for Central Fan Integrated (CFI) Indoor Air Quality ventilation systems, or Central Fan Ventilation
Cooling Systems, that utilize dampers that open only when OA is required and automatically close when OA is not required,
may configure the OA damper to the closed position during duct leakage testing.
03
All supply and return register boots were sealed to the drywall.
04
Building cavities were not used as plenums or platform returns in lieu of ducts.
05
If cloth backed tape was used it was covered with Mastic and draw bands.
06
All connection points between the air handler and the supply and return plenums are completely sealed.
�S
Visual Inspection at Final Construction Stage�(appUcable �f systm was tested a ro gh m)� f
After installing the interior finishing#wall and Verify ing,that4t[iea6ove rough m tests was cdmpletei), the followitg procedure must
k
be performed ti
For all supply and return registers; verify that thespaces'between the "register boob and theinterior finishingwall are
07
properly sealed.
If the house rough -in duct leakage test was conducted without an air handler installed, inspect the connection points
08
between the air handler and the supply and return plenums to verify that the connection points are properly sealed.
09
Inspect all joints to ensure that no cloth backed rubber adhesive duct tape is used.
10
Verification Status
Pass
11
Correction Notes for this table
The responsible persons signature on this compliance document affirms that all applicable requirements in this table have
been met unless otherwise noted in the Verification Status and the Corrections Notes in this table.
D. Determination of HERS Verification Compliance
All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order
for this Certificate of Verification as a whole to be determined to be in compliance.
1 01 1 Complies: All specified verification protocol requirements on this document are met.
Registration Number: 216-A0383010A-M2000001A-M20A Registration Date/Time: 2016-10-12 15:19:21 HERS Provider: CaICERTS
CA Building Energy Efficiency Standards Report Version: 2013 Rev 1.008 Report Generated: 2016-10-12 15:15:39
2013 Residential Compliance Schema Version: 2013.1.007
CERTIFICATE OF VERIFICATION CF3R-MCH-20-H
Duct Leakage Diagnostic Test (Page 3 of 3)
Documentation Author's Declaration Statement
1. 1 certify that this Certificate of Verification documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Darrel Kelly
Company:
Date Signed:
Builders' Energy Services, Inc.
2016-10-12 15:19:21
Address:
CEA/ HERS Certification identification (if applicable):
1478 Bird Avenue
City/State/Zip:
Phone:
San Jose CA 95125
408-202-9075
Responsible Person's Declaration statement
I certify the following under penalty. of, perjury, under the laws of the State of California:
1. The information provided On this Certificate of Verification is true and correct.
2. 1 am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater).
3. The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification
identified on this Certificate of Verification go pl with the: applicable requirements in Reference Appendices RA2, RA3, and the requirements
specified on the Certificate of Compliance for the building approved by the enforcement agency.
4. The information reported on applicable sectionscif the Certificatre(s) of Installaki'kin (CF2R sFgned an s5ibgiii etEbythe persgn(s) responsible for the
construction or installation conforms to the requirement speaf�ed isr the Certificate(slof Coh3plian e (CFSR) approved byfihe enforcement:agency.
availab#e
S. I will ensure that a registered copy' -,of this Certificate of Verification shall be posted or meed with the hLilding pertrt( issued fcrr the
building, and made availabi to th enforcerit nt age n fd at a regisered;copy 6f, this, CertiAcate
Az �k
Verification is'reguired to be included with the documentation the builder provides to the building owner at occupancy.
Builder Or Installer Information As S"hown On'ihe`,C ificateOf Installation
Company Name (Installing Subcontractor, General Contractor, or Builder/Owner):
N/A - Consumer Certificate
Responsible Builder or Installer Name:
CSLB License:
N/A - Consumer Certificate
N/A - Consumer Certificate
HERS Provider Data Registry Information
Sample Group Number (if applicable):
Dwelling Test Status in Sample Group (if applicable)
Tested
HERS Rater Information
HERS Rater Company Name:
Builders' Energy Services, Inc.
Responsible Rater Name:
Responsible Rater Signature:
Darrel Kelly
`Z�'i�/�
Responsible Rater Certification Number w/ this HERS Provider:
Date Signed:
CC2005655
2016-10-12 15:19:21
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration Provider
responsibility for the accuracy of the information.
Registration Number: 216-A0383010A-M2000001A-M20A Registration Date/Time: 2016-10-12 15:19:21 HERS Provider: CaICERTS
CA Building Energy Efficiency Standards Report Version: 2013 Rev 1.008 Report Generated: 2016-10-12 15:15:39
2013 Residential Compliance Schema Version: 2013.1.007
BUILDER'S
E �y /6 Y
SINI VRES
October 13, 2016
City of Cupertino
Building Division
10300 Torre Avenue,
Cupertino, CA 95014
RE: 10676 Carver Drive
Builder: TQ Construction
Please be advised that the above identified home meets and/or exceeds the
minimum green point rating for the City of Cupertino.
Documentation has been compiled throughout the construction process. This
residence has completed all of the CalGREEN mandatory measures meeting or
exceeding the minimum requirements
As required by the City of Cupertino, 1, Eric Kirk, a licensed Green Point Rater and
Mike Vo, the contractor, -has constructed this residence in accordance to the
CalGREEN mandatory measures. If requested, they can show documentation
supporting this. Any questions please call Eric Kirk at 408-806-9901
Sincerely,
Eric Kirk
Eric Kirk
Builders' Energy Services, Inc. .
Green Point Rater # 14293
Corporate Offices
1478 Bird Avenue Sacramento
San Jose, California 95125 Santa Cruz
(408) 718-1908 San Jose
(408) 273-6303 Fax Gilroy
E -Mail: energy@builders-energy.net
CUPERTINO 4
VNEW CONSTRUCTION
CONSTRUCTION PERMIT APPLICATION IgC)60195
COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION
10300 TORRE AVENUE • CUPERTINO, CA 95014-3255
(408) 777-3228 • FAX (408) 777-3333 • building curiertino.or
❑ ADDITION ❑ ALTERATION / TI ❑ REVISION /DEFERRED ORIGINAL PERMIT;#
pRO=T ADDRESS 10676
O6 16 CA WER VK
APN 37!5
2- Q I S
" 32 -
OWNER NAME /
J PHONE. ` 1 C 7 ffv
F -MA
�-�l -e r �!
C,
L3A J
OC
G
^�
STREET ADDRESS } • ao hon)
ClTY, STATE, ZIP Qr�i ; rY/L` () }� ? FAX
rr y'�
CONTACT NAME �! T.
PHONE O E MAII.
f��yl
_ _
�(0
f m ri- es I S Cal
STREET ADDRESS l I � � �+ LD � �v
J
C ' S rArE ZIP ryy 0 h d a rD cT ��J 6
F
-2 �a "Ia 3-3
DOWNER ❑ OWRM-13UU-DER ❑ OWNER AGENT ❑ CONIRACTOR ❑ CONn;ACTOeIR•AFGENT ❑ ARC=Cr ❑ ENGINEER ❑ DEVELOPER ❑ TENANT
CONIRACTORNAME A .
Y B.
LICENSE NUMBER
LICENSE TYPE
BUS. LTC m
COMPANY NAME
EMAIL
FAX
STREET ADDRESS
CITY, STATE, ZIP
PHONE
ARCHCTECT{ENCsiNEERNAMEiICENSENUt�ME.R C4!5 954
Bus. LIC 4
COMPANY NAME.L'KAAIZK DE51&N
EM i
4,()U1
QrIM1
e-, {
STREET ADDRESS ^
oorq (�J V
CITY. STATE��
PHO ag
DESCRIPTION OF WORK D
66
$3 S F G Lr S -r VJR ! k -LE
FPDN—C Pow , CIRlot� 45a.
E3CISTING USE PROPOSED USE
Co"IT, TYPE
# STORIES
-
SD
YE
USE
TYPE OCC,
SQ.FT.
VALUATION (5)
E)aSTG
AREA 12%
NEW FLOOR,
AREA 2533
A �25(o
TNETARrl,2833
_.
BATHROOM
REMODEL AREA
KITCHEN. OTHER,
REMODEL AREA p REMODEL AREA NA
_
PORCHAREA
DECK AREA
TOTAL DECK/PORCH AREA
GARAGE AREA; pETACH
78
V 2 A'rrA—
4-32
DWELLENGUNITS:
ISA SECONDUPOTYES
❑VO
SECONDSTORY YES
BEING ADDED?
ADDrTION? 200
PRE -APPLICATION ❑YTS IF YES, PROVIDE COPY OF
PLANNINGAPPLm ❑NO' PLANNINGAPPROYALLEfl"P.R
[5 THE HLAC AN E)YFS
EICHLERHOhiE? ❑NO
i; E D`8]�
k�'` r`'
��`?- 'V5g }
k[ �*�
{
TOTAL VALUATION'
a
By my signature below, I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf I have read this
application and the information I have provided is corre t. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local
ordinances and statc laws relating to r ang st n. I authorize representatives of Cupertino to enter the above -identified property for inspection purposes,
Signature of Applicant/Agent: Date: 20 ! ,5
SUPPLEMENTAL INFORMATION REQUIREDi>V
New SFD or Multifamily dwellings: Apply for demolition permit for
�0 pR'THECOEiTNTER
rsf�s °� }t
existing building(s). Demolition permit is required prior to issuance of building
�"yUIIDINGAIREAiEW�
-m y
.-
permit for neve building.'1]"ExPs's�"�
Commercial Bldgs: Provide a completed Hazardous Materials Disclosure
g P
® r
sxa
=
Ptr$r tcwagzcv
_
form if any Hazardous Materials are being used as part of this project.]T
Copy Pluming Approval Letter Meeting Planning to
_ of or with prior
r
Rnrsx rc
submittal of Building Permit a lication.
2a� F
iwt
$iYVIRO.C+E'MEI+I"I� "tTEA"liT.$sa..�_-F:,'
BIdgApp_2011.doc revised 06/21/11
N
I BUILDING ENERGY ANALYSIS REPORT I
0.
PROJECT: 'n
Li's Residence 'n
10676 Carver Drive Now
Cupertino, CA 95014 0
Project Designer: M
9
I -Mark Design Group 0
1659 Scott Blvd. Ste 36
Santa Clara, CA 95050 0
408-345-5002 ou
w<
Report Prepared by:
Qui T. Son co
I -Mark Design Group
G,vpERPaenc 1659 Scott Blvd. Ste. 36 f'
j3do:02 Santa Clara, CA 95050
408-345-5002
,a � 0 g 2015 �
09 GOOD co d
�g�tie�e
d gy.
Job Number:
150212
Date: 2pf.
10/13/2015
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC—www.energysoft.com.
User
I TABLE OF CONTENTS I
Cover Page 1
Table of Contents 2
Form CF -IR -PRF -01-E Certificate of Compliance 3
Form RMS -1 Residential Measures Summary 11
Form MF -1R Mandatory Measures Summary 12
HVAC System Heating and Cooling Loads Summary 16
EnergyPro 6.5 by EnergySoft Job Number. ID: 150212 User Number. 6570
r CO
9 �
W
IL d
L- a
U
r
G
O
x
t`
LU
2
U
z
a
IL
2
O
U
W C
U
am'
3
IL w
g c
O m
U
N
L4 N
W G!
a E
U m
z
LL u
t- y
W
0 IL
Lo
T
0
N
T
P7
7+
co
7
P
co
C
O
V
4 ..
.v
CL
Ems:
�i
CL
jq p,
c v�
O
a
U
GI
9
0
.y
E
a
rn
u
0o
a
a
v
fY
o
M
I
m
W
O
E
N
U
Z
N
I
cd
d
C
M
0.
a
10
d
0.
M
W
e
V
�
O
m
0
O
N
N
u7
0
G
X
v
g
47
o
O
dl
fD
r
til
ari
rL
a
0
G
0.
O`
N
d�
k
,
E
io
E
0.
fro °
V
4
U
m
G
a
EW
0
Lo
N
fD
_.LLI
;Z
d
S`N7
N
2P
O
O
O
$IF
O
U
CO
W
6
O
�
�t� k
p
GG
o
o
1Q
d
y
a`
4:
'C
Ems°
a
o
N
d
O
}
7' A
ip
d
C7
d
d
W
N
v
N
s:d
cµ
a
o
E
N
aw
0
tea+-
�
0
c
a
o
C
o
E
E
sa
m
d
co
o o
z
z
3
C
O
N
C
tm
^!o
A
•.
o
O
d
d
O
a
e
e
~
rD
0
I
O
O
e
e
r
Crn
a
a
_
E
O
i
N
W
0
C
W
v
N
U
P
r
Z
a
o
o
o
G
a
C 0
cm
u�
'o
R
c0.
G
C
v
O
0
s
U
c
7C
V
W
r
Co
U)0
OW
O
O
r
r
r
ku
N
r
N
r
0
co
0.
a
N
Q
O
V
N
C
G
in
m
m
a
o
v
o
j=
U
rn
U
d1
Z
N
I o
lz
Z
r
N
(j
U
N
m
z
a
a
u
ul
o
a
w
o,
d
o
d
U)
J
E7
.�
11.
.13
O
y
U
O
M
N
0.
CO
p
m
II.
LL
to
0
N
a
sy
v
r
F.
Q
gO
Z
4
O
LL.
Z
J
W
Z
r
N
t7
a
�o
m
v
N
v
m
m
o
W
O
O
O
O
O
O
r
r
r
r
r
N
Lo
T
0
N
T
P7
7+
co
7
P
co
C
O
V
4 ..
.v
CL
Ems:
�i
CL
jq p,
c v�
O
a
U
u
c
F
w
W
U
U
G7
.y
0
d
x
0
Lh
cli
C)
r -I
n
Ln
-1
0
N
Ln
m
O
a
-q
U
120
7
0
CL
a
w
GI
9
.y
E
a
rn
0o
a
a
v
fY
o
M
I
m
W
O
E
N
Z
N
I
cd
d
C
0.
a
10
d
0.
U
W
e
V
m
0
C
A
0
G
X
v
g
47
o
O
u�
fD
o
O
r
til
ari
rL
a
0
g
N
d�
k
,
E
a
fro °
V
G
N
CD
_.LLI
;Z
d
S`N7
N
2P
O
O
O
$IF
O
O
N
r
6
O
�
�t� k
a
O
a`
4:
'C
Ems°
a
o
N
d
}
7' A
ip
,ter
��
�
Q
d
W
N
s:d
cµ
a
N
0
tea+-
�
0
F
v,
E
z
sa
io
d
LU
O
O
N
C
tm
^!o
A
•.
o
O
d
d
O
a
e
e
~
rD
0
I
O
O
e
e
r
Crn
a
a
_
a
N
W
4
W
v
N
U
Qf
r
Z
a
o
o
o
G
a
C 0
cm
O
'o
R
c0.
G
C
v
O
0
s
U
c
7C
V
W
U)0
u
c
F
w
W
U
U
G7
.y
0
d
x
0
Lh
cli
C)
r -I
n
Ln
-1
0
N
Ln
m
O
a
-q
U
120
7
0
CL
a
w
G
a
E
0o
a
a
v
N
o
M
I
m
O
E
N
O
N
I
cd
C
d
d
0.
e
A
G
dN
C
v
g
47
o
O
u�
fD
o
O
r
til
a
E
V
G
N
CD
d
S`N7
N
m
O
O
O
O
O
N
r
6
O
�
a
O
a`
W
N
}
,a
W
z
LU
C
tm
d
LO
0
~
rD
I
O
O
r
N
V
C
v
N
Qf
r
G
G
o
C 0
cm
O
'o
R
C
v
O
x
s
U
c
7C
W
U)0
u
N
ku
N
0R
a
r
0
R
a
0.
O
V
u
c
F
w
W
U
U
G7
.y
0
d
x
0
Lh
cli
C)
r -I
n
Ln
-1
0
N
Ln
m
O
a
-q
U
120
7
0
CL
a
w
Co
4 �-
� O
Q' N
LL d
Cr I
va
a.
LL-
0
LO
Q]
12
y
O y
M T
C'4 E c
N x m
hi Z v
E co E
co
co OU
ltl E N
❑ ca
c z
n � �
O w 8
7 *+ O
u~i CL E
� U 5
iia
U n
Z a�
Q W
J y
a. p
O
U c
w E
U �
z
a
a
o E
Ir
w
a g
Q G
U
m
U) T
IL1 f0
fr C y
G
y �
J F- 7 m c
EL •�= C H w
CO y O
O a) n LL CI
a
LL
O �c
LLF d ❑ 0. t d
E c w rn sv
ro o ❑
z �_ o W
H y > > o
Cf 7 -
O O ea
Q at G U
ui W
°I
N
r -I
m
N
N
cm
N
0
Lit
O
N
N
N
N
C
Cl
O
b
CI
cr
y
E E
as
7
O
b
F
«
C
A
C
r2
i -
v
N
t7
C)
a
Li
E
C
a2 E
O
ELU
aI
N
•T
C
w
N
LU
v
3
A
E
0
�O
OS
C)
i;
U G
c
ca
E
t
ca a .
Ct
CL
E �
OT]
fffi�`
C7
C
a�
x=
C)
C)
C,
x
E
a�
al
C
Cl
E
r01
�O
C
.s
C
U
C
m
y
N
a.
C)
m
m
m�
d
lY
cu
W
N
S
,7
a�
O
agi
CCLo
I 7
a
p
T
N
T
3
:G><
c
c °Y
Lo C
lD
c
O
to
m
U V''
T �
N
E o
"
LU
N y
r
_
y
C7 H o
p t E
x
O u
42
16 U
C
•Q1
x
0CLc0
E
y 7 E
N
r -,-
C
O U
0� N
�+ •,0--, U y T
'` ?, fA
r2
C
V O
ylLLJ
Co ;3C
C 7 0 �0 C y«p
77+
LC
❑
y.0
�L
C E IL J OY r?
m a.3¢ uM c
'-
aoo
�z y
u TE �«
i=0IW
,0
=�dm
C
LL
Co
�V
C d E MEW 32+2
e— uyo
O1 C7 U m z
W
r o
=
•�Sa p� LL? a Eo [
Z
f -CL
m. .U. .x.❑.
°I
N
r -I
m
N
N
cm
N
0
Lit
O
N
N
N
N
C
Cl
O
b
CI
cr
N C
7 O
C
m
atm
w
c T
m
0 C
m N
m
T
m �
C G
W �
°I y
C L
j O
m �
C C
°I C
y 7
W
❑ u
-2 m
C C.
E E
as
7
O
b
F
«
C
A
C
r2
i -
v
N
t7
N
Li
E
a2 E
ELU
aI
IC O
T
w
C
LU
'a
OS
U
i;
U G
m
C4
a
€x
ca a .
E �
fffi�`
-nit
x=
x
�m
r01
}O
7
C
Fi
a.
�y
m
O y
m�
d
cu
d
N
.r
O
CCLo
I 7
T
N
T
3
:G><
c
c °Y
Lo C
lD
c
O
to
U V''
T �
LU
�
r
O C
?+
p t E
x
Eu
x
❑
z
r -,-
C
Y
P
C
O O cm
a"
a�
m
E m
m
Z
° y y
3
W
C •p
amu°
Cyt
«
❑
y 2 m
y °I c
}
y � m
C
°
N0.0C3
W
Cl
y7 y
� 0 0
� «
U.)
1Zil
O
°I
N
r -I
m
N
N
cm
N
0
Lit
O
N
N
N
N
C
Cl
O
b
CI
cr
N
Li
E
a2 E
ELU
F
IC O
T
w
LU
pI
U
c
E �
�
x=
x
}O
7
C
O y
dcu
N
.r
O
CCLo
I 7
T
N
T
3
c
c °Y
lD
c
CO)
to
C
C]
LU
0 o
=
x
Eu
x
❑
za.3
3
Cyt
C
C
°
N0.0C3
� «
U.)
O
LT Z
of
v
�
N
C
N
=
z
r
o
,p
L
�
a
W
O
O
O
N
Q
LL `'
N
d
C
c
o
v
N
C7
E
F
_
O
E
o
c
o
E
�
❑ y
-ECO
O
y
U
°
T
U
>
'c
E
z
ta
a
N°
O
C3
Q
N
O
O
LL
a
-,ry
N
N
r
C
2
o
m
C
CD
a+
C
C
a
a
O
NO
U
a
a
z
O
a
O 0
a
m
Lo
O
A
LL
z
z
LU
E
c
b
E
Lf)
N
�
z m
O
E
z
m
Q
O
z
0.
WLL
N
Z
c_
m
M
IiJ
N
«
J
1
H
z
N I
I
LD
P]
cr
°I
N
r -I
m
N
N
cm
N
0
Lit
O
N
N
N
N
C
Cl
O
b
CI
cr
T CO
LLL O
M V)
IL m
LL Q
V
Ln
O
N
c+i
v
O
m
1—
Q Ln
US to
C
to
(� -0 N
Z '7 N
a m
I
IL
O
v a
V N
LL V
o a to
D
a m c
V ZLL Z cu
O
i+
IxIx m u
W Q m
V a. Q
I
O7
I7
T
o
0
C
m
m
u
Ix N
c
T
_
o m
o
m
W
W
b
O
O
O
G
0
G
O
O
m
u
o
O
C
os
O)
01
Gl
01
ou
T
G
0)
QI
O!
V
0
h
c�
m
O ..
ao
v,
ao
T
ax
4
r-.
P]
m
i0 a
o
6
t9
N
N
m
A2 N
Z
Z
+�
c6
3
ip K
U]
m
O
kC
Q
7 m
O
14
0
O
co
00
U7
nCL
W W
N
Lo
U1
x a
T�
C3
N
O
N
LO
o
a
a0
m E
O
G
a
�
0
O
s
d{C
C
0
O
W
ca m
o
U
c
Q
t!I
U
o
0
C,
n
0
T
T
}C_
}
0.0'
d
C]
O
a
CD
!Y
r
w
O
o
Pn,
11'1
no
C
Q1
m
C
a
CI
U
m Go
M
y
m
^
mW
7
N
b
m
y
NV'
y�
N
N
N
l9
v
I
N
N
r
Ln
co
c
to
v
v
W
p
G
0
Q
j
c
�
o
0.
a
rn
z
[�
LU
[7
m
O
<1
e
0
o m
m
0
0
oo n
C
6
w
m
z a
C
°1
CL-
m
ro
-
G
C
O
C
m
J
m
ll
tD
Q
ll
rLm
0
E
u
; p
m
E
r'.+
oO
T
aiC
a
E
to
to
Ml
N
LD
C
O
to
to
W
o
O
N
a
C]
N
aj
en
('7
N
N
IN,
0
C
m
C
G N
0
to
to
o
0 vi
'U
U
0
¢
O
M
Q
U
U
Q
� +�+
M LA
Z
E
N CUu
c�
=
W
m
tm
~
m
m
o
10.
E
CD
C
2
Ura
N
U
W
�.
0 m
O
a
cn
C
:o
V
o
-
o
Q
2 m
w
o?
S
a
c
Cc
Q'
Q'
0.'
O
r
r
a
ur
o
._': o
w
w
N
m
m
m
2
S
o
o
o
o
0
0
0
o
N
o
o
0
N
to
to
U]
u]
CO
U)
0
U,,
6
,vy
C9
w
w
w
u
m
N
xA
A
tD
zrn
'osi
C9
10,
"
N
d
(�N
O
7N
yN
@
aCD
LL
cu
Z
O
Q1
OI
N
C
X
O
O
LL
J
m
J
�+
•N
N
LL
CC
�
c
W
d
a
0
I
O)
'E
I7
T
o
0
C
LL LL
m
u
Ix N
c
T
_
o m
o
m
W
m
LL"
O
G
U
0
z
Zfn
ry
m
u
o
C
os
r
V
pn
G
ou
T
G
G
V
0
11C
c�
m
O ..
ao
v,
ao
T
ax
4
r-.
P]
m
i0 a
o
6
t9
N
N
m
A2 N
Z
Z
+�
c6
3
ip K
U]
m
O
kC
IC
a
7 m
O
14
w
C,
nCL
W W
U
U1
x a
T�
N
s '
LO
o
a
a0
m E
O
G
a
�
0
O
s
d{C
C
0
O
W
ca m
o
U
c
Q
t!I
U
o
0
C,
n
0
T
T
0.0'
d
C]
O
a
CD
!Y
r
w
O
o
Pn,
11'1
no
C
Q1
m
N
o
C
Cp
N
N
U
y
�
v
N
�
C
m
b
m
o
y
y�
N
l9
v
I
Ln
co
c
v
v
W
p
G
0
j
c
�
o
0.
a
rn
z
[�
LU
m
O
<1
0
o m
I7
C
N m
Ix N
O
W
m
O
o
U
0
z
Zfn
ry
o
U N
V
fn
0
N
�
O
N
t9
N
N
m
Z
Z
+�
c6
A
U]
m
O
IC
a
7 m
O
w
C,
nCL
W W
U
x a
C
o
a
a0
O
G
O
0
CD
U
c
Q
t!I
U
�
a
T
T
C
d
C]
O
cNv
!Y
r
w
O
o
11'1
no
ti
N
m
o
y�
N
Ln
c
v
v
00
p
G
0
a
E �
as V
m c
O
o m
m
0
oo n
w
m
z a
C
°1
CL-
m
ro
-
C,
C
C
u
C
rLm
E
u
m
E
16
oO
T
aiC
U
o :L3
C
O
O
O
o N
o
N
a
0.
aj
en
N
vr1
0
C
m
C
G N
0
to
to
o
0 vi
'U
U
0
¢
O
M
Q
U
U
Q
� +�+
M LA
Z
E
N CUu
=
W
m
tm
~
m
m
o
E
CD
2
U
W
0 m
O
a
cn
C
:o
V
o
-
Q
2 m
w
S
a
c
r m
4 0
LL
a v
IL 47
�- a
LL
0
LO
T
0
CV
clir
1
0
C
N x
;I 0
E ca
$1 ci
E
0w
O Z
CD
16 LL
16 0.
V c
9
d
e
y
w
Ll]
U
U
O1
0
CL`
LU
LU
It
4n
C4
0
h
N
O
d
O
0
0
Q
M
m
w
LOw
z
I5
N
Q7
E
7
z
C
O
N
aj
rn
N
m
N
N
m
ti
0
Ln
H
O
N
m
b
GI
f+
A
a
C
a
l7
0
m
a
O
h
ll]
C)
0
N
Ln
N
coO
aG
ti
V
C
O
.N
t'
O
Q
cc
O
O
Lq
O
co
n
o
o
a
l0
�g
L
CD
N
u�i
uCi
w
w
0
0
xei_^:r
w
�.
r
d
`
N
d
47
`7
Gl
O
L
fn
fn
VJ
VJ
fA
fn
N
s.:a'
lb,"1
67
a�
,g
3
'
h
C
C
C
C
C
C
C
O
(3N
Y
Z I
N
N
N
N
N
h
N
h
Al
N
,
t
N
N
N
N
N
N
r
N
coM
�i
rr
m
m
m
h
c�
r"
3-11
,�`°,-
0
0
0
0
0
0
0
0
0
mco
o
LD
o
rn
o
rn
O
d
❑
N
O
IE4
C7
N
'[`7
fLO0
C7
N
CD
N
lz
0
Q
0
Y
0
Q
= d
T
o
l
I
I
I
I
1
m
m
z
o
SIIIlI1
S
L
3
IL7
f�i
lC!
N
N
j3
uj
m
r
N
N
Y7
c7
i
Mm
�
O
G1,
d16
�
IO
OI
�
�C
�
b
Ir
.J.
co
m
�
m
N
N
0
C
d
l6
t0
r
Q'
M
O
a
3
N
0
O
O
0
O
0
L
O
L
O
m.
CL
.0
L
C_
tm
-
C
C_
C_'
j_Cy
N
O
O
0
0
N
❑
w
c7
❑
'7
b
4]
O
r
E
z
d
e
y
w
Ll]
U
U
O1
0
CL`
LU
LU
It
4n
C4
0
h
N
O
d
O
0
0
Q
M
m
w
LOw
z
I5
N
Q7
E
7
z
C
O
N
aj
rn
N
m
N
N
m
ti
0
Ln
H
O
N
m
b
GI
f+
A
a
C
a
l7
0
m
a
O
h
ll]
C)
0
N
Ln
N
coO
aG
ti
V
C
O
.N
t'
O
Q
cc
O
O
Lq
O
co
n
o
o
a
�g
RftA°a
en.�Y
yg
:Z•i?ti
xei_^:r
Nom_
�.
Cq-
s.:a'
lb,"1
67
a�
,g
3
'
h
Z I
fi
Al
,
t
3-11
r
' P
X;.
d
❑
N
O
IE4
Cl
0
CD
N
lz
0
0
0
d
e
y
w
Ll]
U
U
O1
0
CL`
LU
LU
It
4n
C4
0
h
N
O
d
O
0
0
Q
M
m
w
LOw
z
I5
N
Q7
E
7
z
C
O
N
aj
rn
N
m
N
N
m
ti
0
Ln
H
O
N
m
b
GI
f+
A
a
C
a
l7
0
m
a
O
h
ll]
C)
0
N
Ln
N
coO
aG
ti
V
C
O
.N
t'
O
Q
cc
T W
� O
jx' N
IL as
cp
r b
LL
U
LD
0
N
[+]
t5
O
a
1-'
0
C�]
(V
N
E
C
.d+
l0
C
O
rt
v
R
U
E
x
dl
U
d
E
R
Z
d
LL
7
CL
S
O
ri
n
ri
0
N
N
co
O
a
U-
u
C
yO
3
t
O
0.
a
Cc
'\.
C
O
U
G
F
w
U
Q
m
N
_
o
9
N
U
0
U
W
.0
N
!� CO
!� •C
'C
d
L
E y
yam„
m CO
ai
E m
�r -
ro
�`
J
aRa�
�N
O kdl
a] N
"-C
O� m
m AQ-
ca
O� j
034 y'
\\-C
a14
\ y•G
•�,4
v Ole(
Cl
J
Q
d
O
N
�
C
E\ a[
b
\ O
�` N
C y
\ U
\ 4
a C y
y b
Z .0 y
y b
.y.. •� N
ti\
W'�
E
Z' ( O 03
V)
5
yQi�
00•�
yMvi 0
.�[)
y �-�
C•+�
Off] O
•C •�
O� 0
O�
N
`�
gzQ a
�Q
aQ:
�Q� H
C o q
C O
U O
N
C9 03 � C
C7 ; �l
CEJ N
N
�
c
o
73
E
m
O
LL
•y �tl C d
'y ~O
CLL
'� fx.1�
O
y J
l}
�[
u U
QL
LL
O
O
c
o
Q
0)
o
z
w\q\y
.�
\�
. ,
\� 0+
Z3 93
10
W
c
N N O O
y 01 {..
�d O O
m O
7
Q
LsUO
�U�a
QUO
QQ:
Uaa
QQ 0
e
O
d
fq
❑
o
O
a
U
La
.10
Oo in
m
M
v
rn
�
' v
03
LU
y
w
x
p
`
d y
O
CI
O
O
O
Q
O
C7
SD
W
O
w
IL
O
LU
C
fA
U)E
c
Z
%
U)
n
E
z
LU
z
to
d
s
a
�
C
O
+�
2-3
M
W
~
to
cc
y d
P;
8.
Y1
Cl
U l0
?
FJ
[7
r
c
c
G"
- - .0
o-
N
N
U
U
d
Li
i
a
U
O
O
C
G
E
�
N
N
LL
xC%l
x
x
CV
�
C
O
�p
xx
O
F
U
U
{U
c
O
v
N
E
0
m
a
N
E'°F:
3
E
�
CD
u
m
E
10
E
E2
�
2
E
� E
E2
nz
N
LL
a
11.
CL
LL
'D'
:t � LL
LL
�
CL
O.
.o
O
6 ca
EX
cu
Z
O
w
%
w
y
_r_c::
Q
Q
LL c)
U
ca->
U
�
Fes••
E
O
_
N
0 z
U
0
ca
U
W
l0
z
-
v
Q
�_
O
n
N
ri
U
c
±+
_
O
Q
O
dtm
[A
[n
U
Lal.
LK
G
0
j
r
.�
R
O
fl1
y
u
p
k
w
o
0
0,
cm
Ci
U
Q
o
a
o
O
ri
n
ri
0
N
N
co
O
a
U-
u
C
yO
3
t
O
0.
a
Cc
'\.
C
O
U
G
F
w
U
Q
m
N
o
•�
LL
o
U
0
U
W
a
T
:
•O
a
(3
O
0
V
d
E
N
a
lxl
�
d
A
�
z
C,
Gui
J
Q
d
O
N
�
v
�
�
y
::
�
r
e
z
a
a
=
x
10
N
r
m
N
N
c
D
�
�
c
o
73
E
m
O
LL
O
ar
ISCL
N
C
`°
o
O
O
O
c
o
Q
0)
o
z
❑
m
y
a
10
W
c
7
Q
4
O
d
fq
❑
o
O
a
U
=
o
c
O
0
O
o
o
LU
y
w
x
r
G
C
°
a
fl1
w
N
�o
m
(D
h
w
IL
O
LU
c
fA
U)E
c
Z
%
U)
n
E
z
LU
z
to
d
s
a
�
C
O
+�
2-3
M
W
~
to
cc
O
ri
n
ri
0
N
N
co
O
a
U-
u
C
yO
3
t
O
0.
a
Cc
7n
0
N
cri
U
O
N
N
0
c*7 �
C'4 x
N .
67 �
E
t U
M d
{d E
p �
4 Y
b LL
V �
to a
U 5
a v
U
C
f2
a
W
U
U
41
q
LUO
a
x
r
0
ui
N
N
i7
N
N
m
0
Ln
ti
0
Y
{Q
10
41
C
C7
t
0
C6
m
cc
O
n
Ln
0
LnN
N
coO
LLPC
ri
U
C
O
0
CL
O`C�
0
E
O
075
no
o
ID
N
C
m
O
N v
0
a
a
Q
An
A
�
lQ
m
a
o
W
o
E
E
Y y
�
N
7n
o
Z
C
C C
F�
co
C
L
w
O
a
�
m
Lo
f
7
t`
m
E.cam='.
C
Y
m
`v
N
`o y.
e
Ln
N
Q1
W
O
t7
LM =
C5
w
C
yW
vv
c
W
m
CD
E
U
E:
W
It
O
o-3-.
O A
cl
O
�
W
W
C7
Y
C
m
0.
�
C
14
m
E
F�
O
N
E
m
CL
a
rn
m
O
pM
Y
W
C
E
a.
W
CD
a
c
z
N
E
E
Q
E
CD
N
C7
Z
o
a
W
�
l0
o
C,
�r
z
U
2
q
NC
O ;
guy
m
v
W
o
A
Z
=
407
0.
N
U
C
f2
a
W
U
U
41
q
LUO
a
x
r
0
ui
N
N
i7
N
N
m
0
Ln
ti
0
Y
{Q
10
41
C
C7
t
0
C6
m
cc
O
n
Ln
0
LnN
N
coO
LLPC
ri
U
C
O
0
CL
d
E
075
no
o
ID
N
e
m
O
o
7
0
a
a
�
Lf
O N
An
A
�
lQ
6 N
y7 g!
a
O
s n
E
m
—co,
E
E
,�
N
7n
o
Z
C
tL
U
IL
=
2
c
Lo
f
N
m
E.cam='.
`
m
v'
� c
N
Vii;
o
W
tm
U
w
C
a7
vv
o.
m
U
E:
W
cl
O
�
W
W
C7
Y
:_..
m
0.
�
C
14
m
E
�iY
O
N
E
N
N
d
�
CO)
W
e l
a.
z
c
z
E
E
Q
E
z
J
,
Z
U
O
V
o
C,
O
U
x
q
NC
O ;
guy
C
4 }.
407
N
z
C7
y
Lo.
z
rn
Q
0
co
P
A
z
O
V
W
a
a
N
U
C
f2
a
W
U
U
41
q
LUO
a
x
r
0
ui
N
N
i7
N
N
m
0
Ln
ti
0
Y
{Q
10
41
C
C7
t
0
C6
m
cc
O
n
Ln
0
LnN
N
coO
LLPC
ri
U
C
O
0
CL
r
O
"r-
47
075
no
o
`=
E Y
U E7
;
y
mX
a
x
.o Y
U
�
Lf
O N
q
401
lQ
6 N
y7 g!
fl.
co
O
s n
E
m
—co,
O
�V
N
'O
m
2
c
Lo
v
U
N
Z
m
c
N
o
W
r
w
m
U
E:
W
cl
O
�
W
W
C7
Y
m
0.
�
C
O
N
E
N
N
d
�
CO)
W
a.
z
c
z
E
E
Q
E
z
J
o
Z
U
O
V
o
C,
O
U
x
U
C
f2
a
W
U
U
41
q
LUO
a
x
r
0
ui
N
N
i7
N
N
m
0
Ln
ti
0
Y
{Q
10
41
C
C7
t
0
C6
m
cc
O
n
Ln
0
LnN
N
coO
LLPC
ri
U
C
O
0
CL
r W
c
%-
LL 0
E
m
N
y.
M
ILI
IL Q/
O O
Y
u7 N
M
H
I
C
U.
�r
a
CI
7
ti
_
N
0 y
g
0
=
C
V
'm
U
LL
(�
w
o
r
Q
o
j
r r
a!
0
o
d
ami
m V
o
w
N ,-
J
u
0
N
w
C,
z
❑
3
Q
o
2
N
O1
LU
CD
H
w
u
O
ti
o
m 0
" m
Q
1
c
�
�
;
.1
a�
v
o
0
0
c
a 0
m
�
m
O 0
p
LU
a
z
z
c
a
In
y
'�
a,
3
cr
o
a0i d
o
CD
m
v
uj
2
S
,n
z
o
w
C3
N
Q<
r
O
O
d
3
m
s
LL
fUuI��
O
W
O
}�
F'
F'
w
d
G
a
C
o
m
�a
v
M
w
.a
a
o
d
❑
N X
n cR
m
Qa
m
I
d
z
C
a
E
_E
o
g.
ff
N
E
k
4d3,
C3
CD
c
0
OD
O ° d
'o
= c
0)
Cl
'�
D V.
,,
N
O O
'3A
�
s.
U.
N
Q
F.. V 7
�
C
_
O
a)
4 U
'-:�'
x .k
LL
LU CL0
C
H
O
d
yy
w
C
}
O
Ln
,
G
7
C
x
m
y
C
Q
IYO
a
Q
Im
Q
0
LL
C
1
C—
N as
"r
U
a
Ql
IV
O
J
,
a
(wj
N
F
vai
§
D0
w
CLEn
J
o
c�
m
a
0)
`Y°
.
o
LL
V
m
a^
M.Nrt
,.,,3
F-
'
N
o
a
,
4T,
m
�
��
W
3
4
13.
LLI
C
rn Q
O
u.
4
v a N
a
Q)
r
Q
m
u,
LU
N
w
�!
r
Q GI
LL
0
w
7
y
G
Z
PL
Ln
a m C
VJ
H
}
r
W
r
W
W
U
Q
m
z
p
7
a`7
r
r
o
E
Y
Q
v d
a
T
z
m
z
N
N
.0
i
d
m
F
O
E
nEi
i
w
=
ra
m
a,
uV. ami
D H
o
E
co
c
7
m
cn
c
o
m
N
N
w
Q
C'
c
�0
m
C7
oa
m
o
m
0
=m
Z
b
}
N
o
=
g
E
Q
r
z
a
z
N
c
a
ro
c
V x w
0
m
n
H
rn
LL
Q
0
c
o
U-
❑
a
❑
u.
F- m
•Q
jL
0
U
V
¢
0
a
U
0
.�w
to
m
0 9L 0
>
=
=
aa
of
N
N
m
N
N
m
ti
0
Ln
0
N
L 7
N
N
C
c
ai
l7
r
0
CL
aD
[C
O
ri
n
Ln
0
N
Ln
N
co
O
K
ri
LL
U
c
0
t
O
4
COC
V- CO
T W
LL
co
LL.
a.
U
LO
O
N
Ca]
U
O
N
Q
E
[V X
N
61 �
co
{9 E
Q
�v
c Z
O y
w
V J
a
U c
G LA
L
� C
a
LU 0 � N
Z 'm
a m
Co
a
LL
O W
LU ai C3
a M o
U Z
U. w+ m
•per V
Lia Q R
LS
C_
R'
QI
N
N
m
N
v
0
v
tA
0
N
l+
w
b
d
C
of
L)
tf
Q
a
O
m
O y
U m
E
E :3
VLai
m c
L W
CL
`O E
� V
Q�
Q. .p
'0 U
L
c m n
a
3
Uv p
C*4
(„moi'
OlC
G
O p
'1
U
Dl 0
A F 61
O.
U w b
E p
CL
ED ME
L
Vl ts
m
C 7 E EL
s•
m
C
._
ycu
ai„�:�xa••
CO
rz C
a
N
w
r
a'2 cJR-
. -s;
N
NN
r
fi
u7
h e mr
al 0 y Vj
•O
aJ
�ta7
0
C
p
•�
W
r
cu
�
t
'” �_�
C "",".
FS
4)
r
Vx�g
OD
O
d1
M
O
cel
C_
C O t^s
m
O
co
E
_ Lh
CO
E to
co
N
N
p
C O
O Oco
O m ,f
��
uN =s
p
� O
mix
O O
o
rn
L
:E U �'
as
._ Z
L
E "Y
p.
3R ?
�r
d
N O ps'
w
p
NU a'
N
is
CL
p •p U
u r
N
'
g
N
wy '
L
H C
•y %�
z
W
N
•o
O b
d N„
.W
W
w.
E
U
►-
N
c•
Z
C.
oC
Fa
'y co
ca
•a
,n
CL `!o' er
9`
W
O
- C M a7 d
Q
U
U
p QL N
C N
a)
c
Ln
G
w
41 y '•p—_,
-0 w
u;
r�
LO
0
6
E
N
�
G7
Lf)CDO
Z
r-
.0 W
m
Lo
F-
EE
L
z
O
05
O)
N
'O m pnm's
c c m m-
=
z
O
Z
m
U
p
L
¢W
C7 1p C C
C
7
Q
U
O
m
f:.L-.. LA
m
LU
L
61
3)
(�
Z=
ai
o
a m
m-0
E m� Q
o
o
0
�, n
(�
Z
O
c
w,
M
¢ct
;
n N
N
U
N Ln
G
a
d
CL
y
N Loo
io l6
fA C
E
:s
ro
y
LU
H
cu
0
LS
C_
R'
QI
N
N
m
N
v
0
v
tA
0
N
l+
w
b
d
C
of
L)
tf
Q
a
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
Li's Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
10/13/2015
Project Address
10676 Carver Drive Cupertino
California Energy Climate Zone
CA Climate Zone 04
Total Cond. Floor Area Addition
2,400 n/a
# of Units
1
INSULATION
Construction Type
Area
Cavi (ft) Special Features
Status
Wall Wood Framed R 13 1,471
New
Door Opaque Door -
no insulation 42
New
Roof Wood Framed Attic R 30 2,396
New
Floor Wood Framed w/Crawl Space R 19 2,400
New
FENESTRATION I Total Area: 351Glazin Percents e: 14.6 % New/Altered Average U-Factor.
Orientation Area(ft) U-Fac SHGC Overhang Sidefins Exterior Shades
0.32
Status
Front (NWJ 37.8 0.320 0.25 none none Bug Screen
New
Lett (Nt7 100.8 0.320 0.25 none none Rug Screen
New
Rear (SE) 127.5 0.320 0.25 none none Bug Screen
New
Right (SWJ 81.0 0.320 0.25 none none Bug Screen
New
Skylight 3.9 0.710 0.73 none none None
New
HVAC SYSTEMS
Qty. Heati . ng Min. Eff
Cooling Min. Eff Thermostat Status
1 central Fumace 93% AFtJE
Split Air Conditioner 13.0 SEER Setback
New
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R-Value Status
HVAC System Ducted
Ducted Attic 8.0
New
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
2 Small Storage Gas 6
0.92 Standard
New
EneMyPm 6 5 b V EneipySofi UserMumbec 6570
RunCode: 2015-10-13722:33:51 ID: 150212
Pae 11 of 16
2013 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
comDliance annroach used. ExceDtions may aDDly. Review the resDective code section for more information.
Building Envelope Measures:
§I 10.6(a)I:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage,
§ 110.6(a)5:
Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of §10-111 (a).
§110.7:
Exterior doors and windows are wcatherstripped; all joints and penetrations are caulked and sealed.
§I I0.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§1 ]0 $(i):
The thermal emittance and aged solar reflectance values ofthe cool roofing material meets the requirements of § 110.8(i) when the
installation of a cool roof is specified on the CF1R.
§110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the C17111.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a
§ 150.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§150.0(b):
Loose Fill insulation shall conform with manufacturer's installed design labeled R -value.
§150.0(c):
Minimum R-13 insulation in 2x4 inch wood framing wall or,have a U -factor of 0.102 or less (R -I9 in 2x6 or O.074 maximum U -
factor).
§150.0(d):
Minimum R-19 insulation in raised wood -frame floor or 0,037 maximum U -factor.
In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
§150,0(g)I:
walls, vented attics and unvented attics with air -permeable insulation.
§150.0(g)2:
In Climate Zones 1-16 with unvented crawl spaces the earth floor ofthe crawl space shall be covered with a Class I or Class II
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of
§ 150.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§150.0(1):
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets therequirements of § I10.8
150.0
§ (q)'
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U-
factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§150.0(c)IA:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening ofthe firebox.
§150.0(c)IB:
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readify accessible, operable, and tight -fitting damper or a combustion -air control device.
§ 150.0(e)IC:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§ 150.0(e)2:
Continuous burning pilot lights and the use ofindoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§ 110.0-§ 110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§ 110.3(c)5:
Water heating recirculation Ioops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of §110.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§ 110.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
ands a heaters.
§ I50.0(h)1:
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
in §150.0(h)2.
§ 150.0(h)3A:
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
dryer vent.
§ 150.0(i):
Heating systems are equipped with thermostats that meet the setback requirements of § 1 I0.2(c).
§150.00)IA:
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
with insulation having an installed thermal resistance ofR-12 or greater.
§150.00)1B:
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R 12 external
insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior ofthe tank.
For domestic hot water system piping, whether buried or unburied: the fust 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 314 inch or larger, all piping associated with a domestic hot water recirculation system
§ 150.06)2A:
regardless ofthe pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A.
§I50.00)2B:
All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve
that allows for installation, removal, and replacement of the enclosed pipe and insulation.
2013 Low -Rise Residential Mandatory Measures Summary
§150.00)2C:
Pipe for cooling system lines shall be insulated as specified in §150.06)2A. Piping insulation for steam and hydronic heating
systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A.
§150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§150.00)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulatiou protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
§ 150.00)3B:
or Class 1I vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class IT vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
§ 150.0(n)1:
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§150.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of §I10.3(c)5.
§150,0(n)3:
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSIISMACNA-006-2006 HVAC Duct Construetion Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§150.0(m)I:
with mastic, tape, or other duet -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than'/. inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in eavities and support platforms
shall not be compressed to cause reductions in the cross-sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§150.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duet tapes unless such tape is
used in combination with mastic and draw bands.
§150.0(m)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R -value rating; duet insulation thickness; and duct labeling.
§150.0(m)7:
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers,
§ 150.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
exce t combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§150.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§150.0(m)10:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§150.0(m)11:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§ 150.0(in)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
§150.0(m)12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum, The
§150.0(m)13:
space conditioning system must also demonstrate airflow? 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy:5 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
§ 150.0(m)15:
an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of? 350 CFM per ton of nominal cooling
capacity, and operating at an air -handling unit fan efficacy of <_ 0.58 W/CFM as confirmed by field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§150.0(o):
central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
§150.0(o)IA:
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in aceordance with
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
§ I I0.4(a):
Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
2013 Low -Rise Residential Mandatory Measures Summary
§1 10.4(b) I:
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and return lines, or built-up connections for future solar heating.
§ 110.4(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§ 110.4(b)3:
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro -
ammed to run only during off-peak electric demand periods.
§110.5:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§150.0(p):
Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§110.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of §I10.9.
§150.0(k)lA:
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §I50.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-8; as applicable.
§150.0(k)IB:
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with the applicable provisions of § 150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§150.0(k)]C.
§130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting er electrical box.
§ 150.0(k)1D:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night Iights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§150.0(k)IE:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §130.0(c). Night lights do not need to
be controlled by vacancy sensors.
§150.0(k)1F:
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of § 150.0(k).
§150.0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§150.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§150.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§ 150.0(k)2D.
Controls and equipment are installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § 150.0(k).
§150.0(k)2F:
Lighting controls comply with applicable requirements of §110.9.
An Energy Management Control System (FMCS) may be used to comply with dimmer requirements if: it functions as a dimmer
§I50.0(k)2G:
according to §110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements of §130.5; and all other
requirements in § 150.0 2,
An Energy Management Control System (FMCS) may be used to comply with vacancy sensor requirements of §I50.0(k) if: it
§ 150.0(k)2H:
functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements
of 130.5; and all other requirements in §150.0(k)2.
§150.0(k)21:
A multiseene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2.
§150,0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen Iighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§ 150.0(k)3B:
the inside of the cabinets, Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
§150.0(k)4:
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§ 150.0(k)S:
A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§150.0(k)6:
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy Iuminaires and
controlled by vacancy sensors.
§I50.0(k)7:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy, or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§150.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fiuorescent luminaries with ballasts to qualify as high efficacy for compliance with §150.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in 110.9.
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and
§ 150.0(k)9A:
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor within 6 hours; and
iii, Controlled by one of the following methods:
2013 Low -Rise Residential Mandatory Measures Summary
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
e. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time elock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the
requirements for an EMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is rogrammed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehieles per site shall comply with one of the
§150.0(k)9B:
following requirements:
i. Shall comply with §I50.0(k)9A; or
R. Shall comply with the applicable requirements in §110.9, §130.0, §130.2, 130.4, §140.7 and §141.0.
§ 150.0(k)9C:
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by §150.0(k)9B or 150.0(k)9D
shall comply with thea licable requirements in 110.9, §130.0, §130.2, 130.4, 140.7 and §141.0.
§150.0(k)9D:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
with the applicable requirements in 110.9, §130.0, 130.2, § 130.4, §140.7 and §141.0.
§150.0(k)10:
Intemally illuminated address signs shall comply with §140.8; or shall consume no more than 5 watts of power as determined
according to §130.0(c).
§150.0(k)11:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
nonresidential garages in §110.9, §130.0, § 130.1, 130.4, §140.6, and §141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§150.0(k)12A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§150.0(k)12B:
i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§1 10.10(a)I:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 20I4,
shall comply with the requirements of § 110.10 throw 110.10 e .
§I 10.10(a)2:
Low-rise multi -family buildings shall comply with the requirements of §110.10(b) through §110.10(d).
The solar zone shall have a minimum total area as deseribed below. The solar zone shall comply with access, pathway, smoke
ventilation, and spaeing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension Iess than 5 feet and ace no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§110.10(b)1:
buildings with roof areas greater than I0,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located ou the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.
§ 110.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§1 10.10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§110.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone, measured in the vertical plane.
§ 110.10(b)4:
For areas ofthe roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§I 10.10(c):
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system.
§1 10.10(d):
A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c)
shall be provided to the occupant.
§ 110.10(e)l:
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§110.10(e)2:
future solar electric installation. The reserved space shall be. positioned at the opposite (load) end from the input feeder location or
main circuit location, and permanently marked as "For Future Solar Electric'.
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Li's Residence
Date
10/13/2015
System Name
HVAC System
Floor Area
2,400
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 910
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD 1
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output perSystem 56,000
18,966
1,391 444
22,051
Total Output Btuh 56,000
0
Output Btuhls ft 23.3
740
1,045
Cooling System
0
0
Output per System 28,100
0
01 0
0
Total Output Btuh 28,100
0
740
20,446
1,391
0
Total Output ons 2.3
1,045
Total Output Btuhls fi 11.7
Total Output s ftrron 1,024.9
24,141
Air System
CFM perSystem
1,070
HVAC EQUIPMENT SELECTION
Alrflaw cfm
1,070
Carrier 58MTB60-12 CNP 38HD 2.5T 23,907
2,849
56,000
Alrflow cfmis ft
0.45
Airflow cfmrron 456.9
outside Air %
0.0%
Total Adjusted System Output 23,907
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
2,849
Aug 3 PM
56,000
Jan 1 AM
Outside Air cfmis tt0.00
Note: values above given at ARI conditions I
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak)
28 OF
Outside Air
0 cfm
67 OF
67 OF 115 °F 115 °F
ai
Heating Coil Supply Fan
1,070 cfm 114 o F
R4DNi .�
68 OF
COOLING SYSTEM PSYCHROMETiCS Airstream Temperatures at Time of Cooling Peak)
88168 OF
Outside Alr
0 cfm-
76162 OF
76162 OF 55154 OF 55154 OF
Coaling Call Supply Fan 56154 OF
1,070 cfm
46.8% I ROOD
75162 OF
EnergyPro6.5 by EnergySoft
User Number. 6570 RunCode: 2015-10-13722:33:51 1D: 150212