Loading...
B-2016-1456CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO: B-2016-1456 22465 PALM AVE CUPERTINO, CA 95014-2711 (357 03 068) ( CLEAN SOLAR INC) SAN JOSE, CA 95112 OWNER'S NAME: SANTOS ROBERT J AND JANICE C DATE ISSUED: 03/02/2016 OWNER'S PHONE: 408-725-8273 PHONE NO: 408-217-8876 LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO: License Class C-10. C-46 Lic. #9 0849 Contractor ( CLEAN SOLAR INC ) Date 03/02/2016 X BLDG —ELECT —PLUMB MECH X RESIDENTIAL COMMERCIAL I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. JOB DESCRIPTION: INSTALL (N) ROOFTOP MOUNTED SOLAR PV (3.45KW) - 10 PANELS I hereby affirm under penalty of perjury one of the following two declarations: 1. I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which Sq. Ft Floor Area: Valuation: $20007.00 this permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county APN Number: Occupancy Type: ordinances and state laws relating to building construction, and hereby 35703 068 authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and PERMIT EXPIRES IF WORK IS NOT STARTED expenses which may accrue against said City in consequence of the WITHIN 180 DAYS OF PERMIT ISSUANCE OR granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal 180 DAYS FROM LAST CA L I SP Code, Section 9.18. / Issued by: ALEX VALLELUNGA Sign tiara Date 03/02/2016 Date: 03/02/2016 i OWNER -BUILDER DECLARA RE -ROOFS: I hereby affirm that I am exempt from the Contractor's License Law for one of the All roofs shall be inspected prior to any roofing material being installed. If a roof is following two reasons: installed without first obtaining an inspection, I agree to remove all new materials for 1. I, as owner of the property, or my employees with wages as their sole inspection. compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) Signature of Applicant: 2. I, as owner of the property, am exclusively contracting with licensed Date: 03/02/2016 contractors to construct the project (Sec.7044, Business & Professions Code). I hereby affirm under penalty of perjury one of the following three declarations: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER 1. I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the HAZARDOUS MATERIALS DISCLOSURE performance of the work for which this permit is issued. I have read the hazardous materials requirements under Chapter 6.95 of the 2. I have and will maintain Worker's Compensation Insurance, as provided for California Health & Safety Code, Sections 25505, 25533, and 25534. I will by Section 3700 of the Labor Code, for the performance of the work for which maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the this permit is issued. Health & Safety Code, Section 25532(a) should I store or handle hazardous 3. I certify that in the perfonnance of the work for which this pen -nit is issued, I material. Additionally, should I use equipment or devices which emit hazardous shall not employ any person in any manner so as to become subject to the air contaminants as defined by the Bay Area Air Quality Management District I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and Worker's Compensation laws of California. If, after making this certificate of the Health & Safety Code, Se tions 25505, 25533, and 25534. exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions or this permit sha �n l�wnur o r autborieze a ,, et7 be deemed revoked. Date: 03/02/2016 APPLICANT CERTIFICATION CONSTRUCTION LE DI A E CY I certify that I have read this application and state that the above information is I hereby affirm that there is a construction lendin6agellcy for the performance correct. I agree to comply with all city and county ordinances and state laws of work's for which this permit is issued (Sec. 3097, Civ C.) relating to building construction, and hereby authorize representatives of this city Lender's Name to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, Lender's Address judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant ARCHITECT'S DECLARATION understands and will comply with all non -point source regulations per the I understand my plans shall be used as public records. Cupertino Municipal Code, Section 9.18. Licensed Professional Signature Date 03/02/2016 ALTERNATIVE. ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION AE 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • buildingaa cupertino.org CUPERTINO p'7 —0-3 _ M PROTECT ADDRESS � � I r /� I APN 357 CwN,ER NAmQ CM v�l 2a t n I PFf • . " Z6 - UZ l J - E-MAILI f 2�� I �, / � C`'� l STREET ADDRESS 22,L f / � A`n ( ^ „Ave CITY, STATE, ZIP J �j y�� I �} 61 r ! kqy FAX i -, CONTACT NAME3 / PHO -I E-T4AIL - ! J (� u� (� Z I •(J&t `• STREET ADDRESS,2,W f� /l CITY, STATE, ZIP C I � r t ( FAX eOWNER. ❑ 01V1`cR-BUIIAER ❑ OWW-TR AGENT ❑ CONMIL+CTOR ❑ CONTi R4CTOR AGRN7r ❑ .A.RC=.CT ❑ ENGINEER ❑ DEVELOPER ❑ TFNAN r CONTRACTOR NAME 6� LICENSE NL11BEPR tn LICENSL� E� BUS. LIC n COMPANY NAME E-MAIL l�I FAX STREET ADDRESS 140 �� t� ``� ` ( y� , D (�� CITY, STATE, ZIP�� ARCHITECT/ENGI.NIEER NAA4E LICENSE NUA4BER I BUS. LIC R 3 COIVQPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE USE of SFD or Duplex ❑ Multi -Family PROJECT IN WILDLA1\1D PROJECT IN STRUCTURE: ❑ Commercial URBAN INTERFACE AREA ❑ Yes �:No FLOOD ZONE ❑ Yes ❑' NO SOLAR PANELS ❑ ELECTRIC VEHICLE CY ARGING STATION ❑ SOLAR WATER FMATING ❑ OTHER: FOR SOLAR PAA'ELS. NUMBER OF PANELSIMNITS: KILOWATTS (COMMERCIAL ONL i7: TOTAL VALUAT DESCRIPTI01,' OF WORK /O C-_VIar n w1 0_ 5 • • • RECEIVED BY ' "_ � � R 4 S - By my signature below, I certify toeach of the following: I am the property owmer or authorized agent to act on the property owner's b half. I ha application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply With all applicable local ordinances and state laws relating to. uildin-g construction author'7e representatives of Cupertino to enter the ab Pe -id n]1tified property for inspection purposes. n � C S ignature of Applicant/Agent: f Date: SUPPLEMENTAL 12\U6ATIP9 REQUIRED OVERTH)rCOUI�T•EE r t- � ❑ .-. � r ,t 3 SG. - � Pi!4pp_2011.doc revised 03116111 LABELS WILL BE ENGRAVED PLASTIC, WEATHER RESISTANT, RED WITH WHITE LETTERING, MIN 1 /2" HIGH LETTERING At the Main Service Panel • .. BREAKER 705.12(D)(7) To be installed at the Main Service Panel: WARNING: DUAL POWER SOURCES SECOND SOURCE IS A PHOTOVOLTAIC SYSTEM WARNING: ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS - TERMINALS ON BOTH THE LINE AND THE LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION MAX AC OPERATING CURRENT: 12.5 A NOMINAL OPERATING AC VOLTAGE: 240 V .•• . iWWI 44011W P 2. To be installed at the junction boxes: 3. To be installed at the DC disconnect (inverter -integrated): 9 To be installed on the Inverter: MAX AC OPERATING CU-- 5. NOMINALOPERATING AC VOLTAGE:40 CEC 690.54 & CEC 705.12(D)(4) To be installed at the AC Disconnect: CAUTIONPHOTOVOLTAIC AC DISC CEC 690.14(C)(2) Buildings with utility services and a PV system shall have a plaque or directory indicating the location of the service disconnecting means and the PV system disconnecting means A 1 '. i Q a 1 - 2246&"Pahn:Ave ;a; L _j `" r _Palm Ay NTS VICINITY MAP LABELS ALL MATERIALS, EQUIPMENT, INSTALLATION AND WORK SHALL COMPLY WITH CEC ARTICLE 690 DC WIRING METHODS SHALL NOT BE INSTALLED WITHIN 10" OF THE ROOF DECKING OR SHEATHING EXCEPT WHERE COVERED BY THE PV MODULES AND EQUIPMENT LICENSE HOLDER'S SIGNATURE (CEC 690.31(E)(1)) AN ACCESS POINT SHALL BE PROVIDED THAT DOES NOT CLEAN SOLAR INC. PLACE THE GROUND LADDER OVER OPENINGS SUCH AS WINDOWS OR DOORS ARE LOCATED AT STRONG POINTS 1445 KOLLCIRCLE., OF BUILDING CONSTRUCTION AND IN LOCATIONS WHERE SUITE 109 San Jose, CA.95112 THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES, Cont. Lic # 910849 OR SIGNS (CRC R331.4.2) ALL EQUIPMENT AND ASSOCIATED CONNECTIONS OF www.cleansolar.com INVERTERS, MODULES, PV SOURCE CIRCUITS, BATTER CONNECTIONS, ETC. AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL BE INSTALLED ONLY BY QUALIFIED PERSONNEL (CEC 690.4(E)) ELECTRICAL RUN IS APPROXIMATE AND WILL BE�.EA�``lr.�?4R DETERMINED IN THE FIELD BY OUR ELECTRICAL INSTALLERS INSTALLATION OF G-001 (10) SUNPOWER SPR-X21-345-WHT MODULES & (10) SOLAREDGE P400 DC -DC OPTIMIZERS & (1) SOLAREDGE SE-300& WOlR9�WEUOPMENT .DEPARTNIE f-001 STC RATING: 3.45 KW BU.ILD,ING DIVISION - CUPERTINO CEC RATING: 3.1 KW APPROVED FS101 This, set of plans and specifications MUST be kept et th` 201 OCCUPANCY TYPE: Rlob`site during construction. It is unlawful to -make CONSTRUCTION TYPE: Ohbnges or alterations on same, or to.devi to AHJ: CITY OF CUPERTINI %refrom. without approval from the Building Offi ial. APN: 357-03-068 Th.e:Stamping of this plan and specifications SHALL 0f-601 PROJECT VALUATION: L 2 13_0.Perm.it or to be an approval of the viola iol-602 of an , ovisions of any City Ordinance or State L w. BY. W�j Z-001 + D.AT E- PERMIT"O� SCOPE OF WORK P PLANS HECKED BY DATE 5 PIA KING DEPT PWRPITINQ Ioc W m 0 o zi CP SITE PLAN NOTES H z M Q 9N co EaTITLE Mal,CUI��RTTIN SHEET; SCOPE OF WOR. Np�i ing Dopart w y y SITE PLAN NOTES ` o SITE PLAN Q REVIEWED FOR CODE CC PLIAME ROOF PLAN Reviewed By: galq ROOF FRAMING PLAN; ELEVATIONS, ATTACHMENT DETAILS U ELECTRICAL LINE DIAGRAM ..EC ELECTRICAL CALCULATIONS SPECIFICATIONS J 7 DRAWN BY: (JPH DATE: '2%24/16 �T Ev: t'026/16 SHEET NUMBER: 0-001 SHEET INDEX (10) (N) SOLAR MODULES FLUSH -MOUNTED; PAIRED WITH (10) (N) DC -DC OPTIMIZERS TO BE MOUNTED UNDER MODULES PITCH: 18' AZIMUTH: 180' TOTAL AREA OF ARRAY: 176 FT2 1ST STORY CONCRETE W-TILE ROOF [AL] ROOF ACCESS POINT FOR ACCESS LADDER E SERVICE POINT & UTILITY METERING FC-91 JUNCTION BOX O INVERTER WITH INTEGRATED DC DISCONNECT - - - - CONDUIT RUN — ­ PROPERTY LINE EQUIPMENT LEGEND (N) INVERTER + DC DISCONNECT (E) MAIN SERVICE PANEL CONDUIT TO BE RUN MIN. 1" ABOVE ROOF SURFACE AND UNDER EAVES LICENSE HOLDER'S I I SIGNATURE CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www.cleansolar.com CLEANLAR CC W on O o- = er � ��� N uJ Q N o L% �cp LO C~.2 Z a 2= G �1 co O 'mr d � N d v coo pr d UP 'TINFO , , r BuifdIng L ap@rtmat MT\Y R REVIEWED FOR CO _ E COMPLIANCE Reviewed By: 0 DRAWN BY: JPH DATE: 2/24/16 REV: 2/26/16 SCALE:1/8" =14" SHEET NUMBER: FS I01 SITE PLAN Module Modules in Array 10 Module Weight - LBSm 41 Total Module Weight 410 Module Width - INCHES 41.2 Module Length - INCHES 61.4 Racking RACKING Ibs./module 5 Total Racking Weight - LBS. 50 Array Total Array Weight 460 Module Area 17.6 Total Array Area 176 Lbs. / Sq.Ft. 2.62 Number of Vertical Supports 16 ,Lbs. per support 28.8 WEIGHT CALCULATIONS 311-611 TRUSSED SPAN 18'-411 FOOTINGS @ MAX. 72" OC RAFTERS .1'@ 24" OC LICENSE HOLDER'S SIGNATURE CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www.cleansolar.com II eteaWsau►R oc cm C�- = SCALE: 3/32" = 14" 99 Um -L! LU &i C-3 C-2 C" a= CP PARTIAL FRAMING PLAN C6 LU Mg) 1"J, 'N.." CUPEW C= 0016 --Pg ep, rtmenro Colo COMPOSITION IA0 2 SHINGLE MODULE CLAMP.R 2 V I IRONRIDGE XR1 0 BLACK RAIL REVIEWED FOR C :COMPLIANCE 30" EAVE OVERHANG QUICK HOOK TILE HOOK Re LLJ QUICK HOOK SUBFLASHING 0 RIDGE BEAM 2 x 411 QUICK HOOK BASE PLATE CL CL TRUSSED RAFTERS (2) 5/16" X 3-1/2" STAINLESS ►DRAWN BY: JPH 211 x 4" @ 24" OC STEEL LAG BOLTS MINIMUM DATE: 2/2.4/16 2-112" EMBEDMENT REV: 2/26/16 .EXTERIOR WALLS NTS ELEVATION DETAIL NTS SHEET NUMBER: ATTACHMENT DETAIL I S-201 1. MODULES ARE BONDED TO RAIL USING IRONRIDGE INTEGRATED GROUNDING SYSTEM (SEE ATTACHED SPEC SHEET) 2. WHEN UTILIZING THE 120% RULE, BACKFED PV BREAKERS WILL BE INSTALLED AT OPPOSITE END OF THE BUS BAR FROM THE MAIN BREAKER. A PERMANENT WARNING LABEL TO BE INSTALLED PER SYSTEM SIGNAGE, SHEET G-001 3. THE GROUNDED CONDUCTOR AND EQUIPMENT GROUNDING CONDUCTORS SIZE #6 AND SMALLER SHALL BE IDENTIFIED CONTINUOUS FOR THE ENTIRE LENGTH 4. FOR ALL SYSTEMS OVER 250V, CONCENTRIC AND ECCENTRIC KNOCKOUTS SHALL BE PROPERLY BONDED 5. THE REQUIRED DC GROUNDING ELECTRODE CONDUCTOR SHALL NOT BE TERMINATED AT THE AC SERVICE TERMINAL BAR. THE CONDUCTOR SHALL TERMINATE AT A GROUNDING ELECTRODE 6. TOTAL VOLTAGE DROP: 0.7% (10) SUNPOWER SPR-X21-345-WHT Modules paired with (10) SOLAREDGE P400 DC -DC JBox Nema 3R OPTIMIZERS wired in series string [A] Free Air (2) #10 AWG PV wire (1) #6 AWG Bare Copper EGC/GEC (1) SOLAREDGE SE3000A-US-U Inverter with integrated DC disconnect — — — — — — — — — — ---------------- AC I I I DC [B] 1 /2" EMT conduit [C] 1 /2" EMT conduit (2) #10 AWG THWN-2 Wire (3) #10 AWG THWN-2 Wire (1) #8 AWG THWN-2 EGC/GEC (1) #8 AWG THWN-2 EGC/GEC Utility Service 120/240V EXISTING 125A SERVICE PANEL TO BE UPGRADED (SEPARATE PERMIT): 200A Main Meter 200A Main Service Panel 200A Main Breaker `1 MIK-01 (N) PV OCPD 2P 20A I VI'' CU `, L — — 'Y p! l�lldi (N) #4 GROUND ROE " (N) #4 WATER PIPE REVIEWED FOR Reviewed B' I LICENSE HOLDER'S I SIGNATURE CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www.cleansolar.com LTAI' ,30. AK W m C= o- GC v W o cra N �' Q Cm N c C-2 m � CP � Z oQ-zr- o Q o d N a w C= C2 :-RIT IDepaggent 2 2616 ODE CONIPLIAN %V'�od 0 ry n DRAWN BY: JPH DATE: REV: SHEET NUMBER: ELECTRICAL LINE DIAGRAM E-601 PV Module Electrical Specs Sunpower SPR-X21-345-WHT Maximum Power (Pmax) 345 W Open -Circuit Voltage (Voc) 68.2 V Short Circuit Current (Isc) 6.39 A Max. Power -Point Voltage (Vmp) 57.3 V Max Power -Point Current (Imp) 6.02 A Series Fuse Rating 20 A Inverter Electrical Specs SolarEdge SE3000A-US-U Maximum Input DC Voltage 500 V Maximum Input Current 9.5 A Nominal DC Input Voltage 350 V Maximum Output Power 3300 W Maximum Continuous Output Current 12.5 A Maximum Efficiency 97.5 Optimizer Electrical Specs SolarEdge P400 Maximum Input DC Voltage 80 V Maximum Input Current 12.5 A Maximum Output Voltage 60 V Maximum Output Current 15 A Min/Max String Length 8 - 25 # Maximum Power Per String 5250 W System Information Total Number of Modules paired with DC -DC Optimizers 10 lumber of Optimizer Strings at Inverter 1 lumber of DC -DC Optimizers in Series String #1 10 Values at DC -DC Optimizer (SolarEdge P400) Number of Modules in Series per Optimizer 1 # Module Max. Output Voltage (1 x 68.2 x 1.14) 77.7 A Optimizer Maximum Allowable Input Voltage 80.0 V Number of Modules in Parallel per Optimizer 1 # Module Max. Output Current (1 x 6.39 x 1.25) 8.0 A Optimizer Maximum Allowable Input Current 12.5 A Values at DC Disconnect (SolarEdge SE3000A-US-U Inverter) Max. Power -Point Voltage 350.0 V Maximum Power -Point Current 9.5 'A Maximum Voltage 500.0 V Maximum Current 15.0 A AC Values at Inverter Nominal Voltage/Operating Range 211-264 V Utility Voltage 1201240 V CEC Efficiency 97.5 Overcurrent Protection (12.5 x 1.25 = 15.625) 20 A Wire Size Calculations Wire Section (refer to line diagram) [A] [B] [C] Min. Ampacity Required 18.8 A 18.8 A 15.6 A (Opt/Inv Max Current x 1.25) Conduit Type & Size FREE AIR 1/2" EMT 1/2" EMT Wire Size 10 AWG 10 AWG 10 AWG Wire Type PV WIRE THWN-2 THWN-2 Wire Ampacity at 30' C 40 A 40 A 40 A Wire/Conduit Location Behind Modules >3" Roof - Exterior >1" Exterior Ambient Temperature 52 OC 36 OC 36 OC Rooftop Conduit Adder (per 0 °C 22 °C 0 °C CEC 310.15(B)(3)(C)) 52 OC 58 OC 36 °C Total temperature to derate: Ambient Temp Correction Factor (per 0.76 0.71 0.91 CEC Table 310.15(13)(2)(A)) Multiple Conductor Adjustment Factor (per CEC Table 1.0 1.0 1.0 310.15(B)(3)(a)) Wire ampacity after applying 30.4 28.4 36.4 correction factors Busbar Calcs - 120% Rule Size of Main Buss 200 A Size of Main Breaker 200 A Size of PV Breaker 20 A 200 + 20 <= 200 x 1.2; 220 <= 240, WUPE. ... I NO Building Departmen �eAR 0 2 2016 REVIEWED FOR CODE COM Reviewed By: ELECTRICAL CALCULATIONS LICENSE HOLDER'S SIGNATURE CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www.cleansolar.com L�4►:N�4I.JkR 1-- OC W m C= N LAJ Q 09 CV Jo ED cp LO Q Z air- L U Q CEO l� OHO 6LJ C= G. w N (Z 003 �, C= v H Q C/2 U W O IANCE DRAWN BY: JPH DATE: 2/24/16 REV: 2/26 16 SHEET NUMBER: E-602 More than.21%':Efficiency _ Ideal;-forroofs where spate Sat a premium Cir° wrlere fut(ire:expanslpn'inight-be needed Maximum Performance D,'es geed to.deliver the rnost;enecgy in demanding teal world.conditions;: in partial, shade and hot rooftcip terhperatutt-. Premium Aesthetics SunPowerO S; gni tureTM' Blaclt`X Series, panels blend `harfrion[ou`sly i cwyb& roof. The most.- elegant choice for your home: •Makeon®Solarkells .F.undarnenfaflYbefferl- -"Engineered for;performance designed for:,durabt ity Engineered for Peace,"of-Mind D'esgned_to:deliver:consisterlt; trouble free. enet gy,over:a.very long,lifetime: 3A Designed `for .D'urablaity, l _ I The:Su'hPowe"r Maxeon S0I"a Cell is.the onlycell ; built;on a'solid copper. foundation. Virtually im e`rvious tolthe cori-osion and cracking that, j degrade Conventional` Panels'3: j j Same:excel€entdurabiltty asE>5eries'panels. j -#1' Rank,in Fraunhofer durability test:? i '100%,06wer,maintained'in Aflas 25+ ggmp�. fi' rs[ve Durability test10 Unmatched Performance, Reliability & Aesthetics X. SERIES SIGNATURET" BLACK SPR-X21-345 SPR-X21-335-BLK Highest Efficiency5 Generate more energy per square foot X-Series residential panels convert more sunlight to electricity producing 38% more power per panel,' and 70% more energy per square foot over 25 years.' 2.1 Highest Energy Production' Produce more energy per rated watt High year one performance delivers 8-10% more energy per rated watt.2This advantage increases over time, producing 21 % more energy over the first 25 years to meet your needs 3 z 120% 110% i5 .B t00% 3 p 90% o_ 80% w 70% } 60% era 50 % 0 >J >9 C c r 2.1"%' SunPower X-Series 3646 more, year 25 Conventional _J 5 10 15 20 25 Years ----------- -- ----- Maintains High Power at High Temps No Light -Induced p Degradation l F(Igh Average Watts- I /4 Better Low L1ght and Spectral Response High -Performance Anti -Reflective Glass Sunpower Offers The Best Combined Power And Product Power Warranty Product Warranty t00% 95% SunPower 90% 85% a0% 75% 0 5 10 15 20 25 0 5 10 15 20 25 Years Years -Conventional Pancl tinear^warranty , More guaranteed power: 95% for first 5 years, Combined Power and Product defect 25 year coverage -0.4%/yr. to year 25. 7 that includes panel replacement costs... Electrical Data SPR-X21-335-BLK SPR-X21-345 Nominal Power (Pnom)17 335 W 345 W Power Tolerance +5/-0% +5/-0% Avg. Panel EfficienCy12 21.0% 21.5% Rated Voltage (Vm ) 57.3 V 57.3 V Rated Current (Im ) 5.85 A 6.02 A Open -Circuit Voltage (Voc) 67.9 V 6&2 V Short -Circuit Current (Isc) 6.23 A 6.39 A Max. System Voltage 600 V UL & 1000 V IEC Maximum Series Fuse 15 A Power Temp Coef. -0.30% / °C Voltage Temp Coe Vo I T £ - 67.4mV/ C 1 0 Current Temp Coef. 3.5 n-A/°C REFERENCES: 1 All comparisons are SPR-X21.345 vs. a representative conventional panel: 250W, approx. 1.6 rn , 153% effidency. 2 Typically 8-10% more energy per watt, BEW/DNV Engineering `SunPower Yield Report"Jan 2013. 3 SunPower 025%/yr degradation vs. 1.0%lyr corn. panel. Campeau, 2. et al. 'SunPower Module Degradation Rate,' SunPower white paper, Feb 2013; Jordan, Dirk "SunPower Test Report" NREL, Q1-2015. 4 "SunPower Module 40-Year Useful Life° SunPower white paper, May 2015, Useful life is 99 out of 1 in than power. 00 panels operating at more t d pc e . 5 Highest of over 3,200 silicon solar panels, Photon Module Survey, Feb 2014. 6 1% more energy than E-Series panels, 8% more energy than the average of the top 10 panel companies tested in 2012 (151 panels,102 companies), Photon International, Feb 2013. 7 Compared with the top 15 manufacturers. SunPower Warranty Review, May 2015. 8 Some restrictions and exclusions may apply. See warranty for details. 9 X-Series same as E-Serles, 5 of top 8 panel manufacturers tested In 2013 report, 3 additional panels in 2014. Ferrara, C., et al. "Fraunhofer PV Durability Initiative for Solar Modules: Part 2". Photovoltaics International, 2014. 10 Compared with the non -stress -tested control panel. X-Series same as E-Series, tested in Atlas 25+ Durabillty test report Feb 2013. 11 Standard Test Conditions (1000 WW irradiance, AM 1.5, 251 C). NREL calibration Standard: SOMS current, LACCS FF and Voltage. 12 Based on average of measured power values during productlon. 13 Type 2 fire rating per UL1703:2013, Class C fire rating per UL1703:2002. 14 See sales person for details. See httpl/www.sunpower.com/facts for more reference information. For more details, see extended datasheee www.sunpower.comidatasheets. Stanclard.tests13 certificationsTests And UL17Q3;Cfype,2 Flre Rating) IEC 61215, lEC:6:173p; QLiali � Certs ISO 9001:2008,.ISO 14001:2004 EHS:Compliance RoHS,.QHSAS18001:2007, lead-free, REACH' SVHG155,. RV Cycle ,Sustainabili Cradle -to Cradle (di "ible-for LEER oints)1 i Ammonia test IEC62716 De'sert'test 10,1109/PVSC 2013.67. 4437 `Salt S ra .test IEC61701 (maximum severity), PID test Potential -Induced De radationfree:1000V9 Available listirt "s. UL, CEC, TUV,;MCS,,FSEC' Operating Condit ion And Mechanical Data Temperature 401F to +1856F (- 40°C to +850C) Impactresistance. 1 inch'(25mm)'diameter hail at 52 mph (23' mis) Appearance . Class A+ Solar Cells 96 Monoc" stalline Maxeon Gen III Tempered Glass High transmission tempered Anti -Reflective junctioiT Box IP 65, MC4 Com atible. Weight 41 Ibs (1 &6 kg)' G5.Frame Wind:'62psf`3000Pa;'305ISg/m?front&faack Max load Snow: 125 psf, 461� "Im2 f n� 4 63 Frame- Wind:80 psf 240 `Pal l` 2 ont Via, Sno Ar.112 psf,- $0. Pad O lglm8f,al d I Frame Class! black;anodized (hi eA�cM45fti ate ° to MIME {„%j CPQ¢I �p1 5ER 9 Del N 46 1558,mrn 1 51n [61,3in] �i VIEA - FOR COD t as mm 62 21ni R`i,�FRAIGIEPROrILF1 1046 h1m No[ Inv siMountt on pa[@le [41:2 in] I T- 32 mm [13,in1 LONG SIDE 2Zmm [0.9 iN 51id0.T SIDE G5 frames have no mounting holes, Please read the safety and installation guide: Document # 504828'-Rev E /LTR_U5 PHOTOVOLTAIC MODULE SPECIFICATIONS CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www.cleansolar.com ctFnNldu►R W m a = � LO r` N G L.Li Q 07 CV `7 n v CP LO U 2M 4o.,Z LLj Q c 00 d en W 'd, � rr CM t/3 y O cz ISO� tmenr, y ,OMPLIANCE aw-aw U w U Of a_ DRAWN BY: JPH DATE: 2/24/16 REV: 2/26 16 SHEET NUMBER: Z-00 1 solar =s" SolarEdge Single Phase Inverters For North America SE3000A-US SE380OA-US / SE500OA-US / SE6000A-US SE760OA-US SE1000OA-US / SE1140OA-US Single Phase Inverters North America solar =se z. SE3000A- US/ SE3800A-US/ SE5000A-US/ SE6000A-US/ SE760OA-US / SE1000OA-US / SE11400A- US I SE3000A-US I -SE3900h-,US I -SESOOOA-,US I SEisom-us j SE760OA-US I SE10000A-; US I SE11:400A-US I Nominal AC Power Output 3000 3800 5000 6000 7600 9980 @ 208V 11400 ........ I ................................. ................ ............. I . ....... I ......... ................ ...... I ......... . 1QIPRR49y . .................. Max. AC Power Output 3300 4150 5400 @ 208V 6000 8350 10800 @ 208V 12000 ........ . 5450 @240V ..... ................ .. 1.0950.p Output "''V, Voltage "M'I'n'."N"o'm"-"M"a'x'.�"*) . .......... * ...... , " * * ­_✓- - ..... V . Z49Y . ................... AC 183 - 208 - 229 Vac ... I .. ................. .1, .............. AC Output Voltage Min.-Norn.-Max.0) 211 - 240 - 264 Vac ...... I .................................. AC Frequency Min.-Nom.-Max.11) ......................................... Max. Continuous Output Current .... I ....... ........................... GFDI Threshold . .......... ........ .................... Utility Monitoring, Islanding Protection, INPUT Maximum DC Power (STC) ........................................... . ..Transformer -less, Ungrounded • .... ax:.InputValt e ...................... . lilt Nom. DC Input Voltage S................. I ..................... . Max. Input Currenell ................ I .......................... . - _r,.- Max. Input Short Circuit Current ..... Reverse -Polarity ............ . ..GrRyRq-.Fau.1t.l.s.ol.a.tio.n.De.t.ection ..... Maximum Inverter EfficienRy .......... . ............ I ................. CEC Weighted Efficiency I. Niehtiim,*e"Power 'Consumption' ..... USA -GERMANY -ITALY -FRANCE -JAPAN -CHINA -AUSTRALIA -THE NETHERLANDS -ISRAEL www.solaredge.us CLEAN SOLAR INC. 1445 KOLL CIRCLE., VA SUITE 109 ........... San Jose, CA. 95112 VA .......... .... I ...... ............... . I ............... ................ .. I ............. ........... I ...... ................ ..... V V ✓ ............... I ................. I ................ I ................ .................. .................. ..... ..... 59.3 - 60 - 60.5 (with H1 country setting 57 - 60 - 60.5) Hz 25 32 I...42 47.5 A .16...... . 6 ... I.... 2 ... I ............ .......... I 12 5 A ............................. I ....................................................................................... ........... ntry Configurable Thresholds Yes Yes ..... ..... # Yes 50 0 c ....... ................................................................................................................ 325 @ 208V / 350 @ 240V Vdc 5 1 3 i6 1 18 .......... 23 @ 208 . ... ...... 45 .... Adc ......9 ......... ............... . 1 30. . ........3............ ... ......................................................................................................................... 45 ��­­ ...... ....................... I ................. I ................ Yes ........................... I ............................... ........... 600ka Sensitivity .................. ....... ......... ........... 97.5 98 97.5 @ 208V 1 ...... 1 97.5 ................ 97.5 97 @ 208V 97.5 % ........ ..... ......... .e. 249y.. 1 ................ ................ .. < 2.5 < 4 W AoblITIONIAL FEATURES Supported Communication RS485, RS232, Ethernet, ZigBee (optional) ' * .... .. . .... .. Revenue Grade Data, ANSI LY2­1 6 P*t' I o-n' a' I I . ...................................... ............ ........................................................................................... ........... ........... Rapid Shutdown — NEC 2014 690.12 Functionality enabled when SolarEdge rapid shutdown kit Is Installed() STAN DARDIZIOMPLIANCE: ..Safety ..... I ............................ ................ I ............. ULI.74.1.,.U.LI6.99.B,.ULI.998.,.CSA.2.2,2 .................................. I .... . ........ Grid Connection Standards ........ ... IEEE1547 ........ .................. ........ ... ... ...... Emissions FCC part15 class B INSTALLATICKSPEICII 01CATIONS AC output conduit size W l/ AG .. . , . 'conduit . ........................... 3/4." minimum /. 1.6-.6.AWG ......... ............... I ............ . , . . ... 3/4". minimu.m./.8-3. AWG ..... . .. , ....... DC input size /# of strings 3/4�'minimum / 1-2 strings / 16-6 AWG 3/4 / 1-2 " minimum strings / AWG Dimensions with Safety Switch 30.5 x 12.5 x 7.2 / 775 x 315 x 184 X x in/ Weight Safety Switch 51.2/23.2 54.7/24.7 .... 775 .............. x 315 x 260 Mm I�E RTIN with ...................................... ...................... ......... .................................. ................ Natural convection ...... ....... Kilding Departn Cooling Natural Convection and internal Fans (L fan (user N.AR.10 2016 ...................... .................... . .......... ....................................................... . . r9plAwOM ......... ..... . ...... ..... ..2 Noise *'*..... ", '_, "Temperature, -, '' ­ ................ <25 * ....... ......... ...... <50 ....... * --- * ..... * ................. dBA ........ fn".'_K6x'.' Operating -13 to +140 / -25 to +60 (-40 to +60 version availablel") REVIEWED FOFR`CODE CC ..qM99 ................................... ........... I .................... I ......................................................................................... ........... Protection Rating ....... ... ..... ..... . III For other regional settings pleas a cent a ct Solar E d ge supper L i') A higher current source may be used; the inverter will limit its Input current to the values stated. Revenue grade inverter P/N: SExxxxA-US000NNR2 (for 7600W Irwerter:SE7600A-US002NNR2). Rapid shutdown kit P/N: SE1000-RSD-Sl. tsr -40 version P/N: SExmM-US000NNU4 (for 760OW [nverter:5E760GA-US002NNU4). 0 Ik To - INVERTER SPECIFICATIONS Cont. Lic # 910849 www.cleansolar.com C= a Uj mr =0 LO C= C.-j LU Q C" CX CP di CaC-5 In C=L g rC-,j LAJ co- co 00 Mr W CD VQ c0i CCIJ = C-2 Cn IPLIANCE 0V� 0 ry n DRAWN BY: JPH DATE: 2/24/16 REV: 2/26/16 SHEET NUMBER: Z-002.1 solar =se solar =ee z SolarEdgeftwerOptimizer Module Add -On for North America CLEAN P300 / P320 / P400 / P405 SOLAR INC. SolarEdge Power Optimizer 1445 KOLL CIRCLE., SUITE 109 Module Add -On For North America San Jose, CA. 95112 P300 61)-cell afodu16), Ono, (for high -power 60tocell modules) P400 (for,72 &_96,ceII modules) P405 (forthin-film(for modules) I NPLIT- Cont. Lic # 910849 Rated Input DC .Powerll) Absolute Maximum Input Voltage (1/OC at lowest ...,.......................m.,p.....,........... MPPT Operating Range.....................................8-48. ........... ... 300 . I ............ 32q ............ ........... I ....400............ ................405............ 48 80 125 .......... 1. .......... ...... .................... ....................-................... 8.-90...................12.5105............ ........W ...... Vdc .. .............. Vdc....... P300 P320 P400 P405 www.cleansolar.com Maximum Short CIrcuitCurrent(1sc) ............................... Maximum .............. ..: .........................I...... Maximum �iiciency ...............D..C..I.n.p.... ......I...... ...... iq 10 ... .......... ................ ................................... 12.5 13.75 12.5 ........I.................................... 99.5 ....................................................................................................................... Adc ..... Adc 0 ..... Weighted Efficiency ........ Overvoltage Category 98.8 ...... ........ ....... * .............. * ...... * ....... .. a ....... * ...... Ct"EAK 459LA OUTPUT DURING OPERATION�(POWER,,6PTIMIZER,CONNECTEDtTO OPERATINO'SOLAREDGE INVERTER) Maximum qy�p Current ............... 15 .............. ............. ....................................... .................... I ..................... .... Adc ..... Maximum Output Voltage- 60 I 85 Vdc OUTPUT DURING STANDBY (POWER -OPTIMIZER DISCCiNNtCTED:FROM :SOLP�REDGE,INVERTEROR SQLARED.GE- INVERTERDFF)- Safety Output Voltage per Power Optimizer 1 I Vdc I ­T 3 1, JAN, OW! 4. jr, 7 4 PV U 'power optimization at the mod le-leve I Up to, 25% more energy Superior efficiency (99.5%) Mit.igatq's all types of module mismatch loss..es,'from manufacturing Xoleran6e topartiaj,shading Flexible system design for maximum space utilization Fast installation with a single bolt Next generati.on maintenance,withmoddle-level -monitoring Module4evel voltage:shutdown for installer and,firefighter s:afety USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA www.solaredge.us a, i m i m uA n Lj %�.%j ivi r L I M IM I— Q I EMC ... .................. ...................... FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 ................................... I ............................................. ............................ ............. �ie ................ IEC621091(class II -,�� U.L.17.41 .............. ................. ...................................... ........ RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltag� 1000 I ................................................................................. Vdc .............. .............................. ... Compatible inverters .................... ............. .......... I ......... . . . ......................... AI.I.S.ol.arE.dg.e.Sin.gl.e.P.ha.s.e a.nd.Th.r.ee.P.ha.se.inverters .... ... .... .......... . . . . .............. Dimensions (W x L x H) 128 x 1 52 x 27.5 128 x 152 x 35 128x i52x48/ mm/in 5 x 5.97 x 1.08 5 x 5.97 x 1.37 5 x 5.97 x 1.89 ... ...................... ............................ .............. ............................. I .............. Weight ........ ......................................................... .770/1.7 930/2.05 930/2.05 ...................................................... ..................... ... ............ Input .:­:­..... . ........................................................................... .MC4 Compatible .............. Output MTTYpiConnector ................ Double Insulated; MC4 Cof!�po!�e.................................... ......................................................... .......... .............. ..qy!pyt Wire .l_ &.t� ­ * �9 0.95/3.0 1.2/3.9 ........................................... ........ ................................................ I m/ft .............. .4e41�g Temperature Range . -40 - +85 / -40 - +185 'C/'F Protection................ ... ..... W................................................ NM? .............. RelativeHumidity .... ................... .......................... 0-100 ................................... ........ ............................................ % .... ...... Rated STC power of the module. module of up to +5% power tolerance allowed. CUPERTI PVSYSTEIM',DESIGN USING SINGLE TH REE. PHASE 208W THREE PH W - � A Bui ldin,0 Depa A Z1ULAKtUUC INVERTER Minimum String Length 8 J Power Optimize s) ................... Maximum String Length 25 (Power Optimizers) ...................... ............................. ..Maximum .Power .pe.r.S.t.r.ing ............ ....... ........ 5250 ..... Parallel Strings of Different Lengths or Orientations ....... I ...... I .............................................................. I'l It Is not allowed to mix P405 with P300/P400/Pr,00/P71I0 In one string. 10 .... ..................................... .... 25 .... ..................................... .... .... ................6000........... .... Yes ............................................... 18 20 ........... so ....... 12 755 E V-1 -E VV E D- -[�D R - C 0 D E ........................................... <1D Reviewed BY: lav, I ...... I .............. OC-DC OPTIMIZER SPECIFICATIONS ll— C= Cn Lii C= Cn LU QON 23 CP V CP CS LU C= LO Co CIO C= ient DMPLIANCE uad LU 0 Of a_ DRAWN BY: JPH DATE: 2/24/16 REV: 2/26/16 SHEET NUMBER: Z-002.2 1r-p #3 TYPE 1 (PHILLIPS) DRIVE ON SCREW 10 1.50 0 1 0 0 SLIDE TO DESIRED LOCATION I 0 O 1 0 0 .75 2.50 BOTH SIDES OF SLOT SERRATED 0.39 p �----- 6.00 --1 IDENTIFYING MARK ON QMHLS ONLY DETAIL E SCALE 1 : 2 DIMENSION QMHSS QMHLS A 6.57 6.30 B 2.21 1.93 C 1.89 1.60 D 6.27 6.00 ITEM DESCRIPTION QTY. a DO NOT USE IMPACT DRILL ON SCREW NO. 1 BASE PLATE, QUICK HOOK, 6", 6061-T6, MILL 1 0UICk Mount P`' " 2 LAG SCREW, HEX HEAD, 5/16" x 3-1 /2", 18-8SS 2 TITLE: 3 QUICK HOOK, STANDARD/LOW HEIGHT, VERTICAL, 1.5', 6061 1QMHSS & QMHLS: QUICK HOOKb, MILL 1 FOR SIDE MOUNTED RAILS 4 SCREW, SELF -TAPPING, #12 X 5/8", 18-8SS, MILL 1 UNLESS OTHERWISE SPECIFIED. I SIZE I DRAWN BY: RAD I REV 5 SUBFLASHING, QUICK HOOK, 6" BASE, 9" X 14" X .032", 3003-0, MILL 1 DIMENSIONS ARE IN INCHES TOLERANCES: A DATE: 1/19/2o15 8 FRACIIONALt 1/8 THE INFORMATION CONTAINED Pl TM DRAWING IS THE SOW PROPERTY OF QUICK MOUNT PV. ANY REPRODUCTION IN PART OR AS DO NOT SCALE DRAWING TWOFLACEDECIMAL t.18 A WHOIE WIIHOUTTHE WRRIEN PERMISSION OFQUICK MOUNT PV ISPROHIBITED. I THREE PLACE DECIMAL t.125 SCALE: 1:8 IWEIGHT. 1.82 SHEET OF Quick Hook'SS & LS Instructions for Installing Standard and Low Height Hooks for Side Mount Rails Installation Tools Required: stud finder, tape measure, utility knife, drill with 7/32" bit, impact drill with 1/2" socket, caulking gun, appropriate sealant compatible with roofing materials, roofing bar, hand broom, stapler,18" wide piece of underlayment or materials for 3-course method during deck flashing installation. Remove the tile at selected location of the mount. Rest the base plate over center of rafter and mark Connect hook to base plate and drive lag screws Locate and mark the center of the rafter. center of holes. Drill two 7/32" pilot holes and fill into rafter through the two holes to a solid, snug fit. with sealant compatible with roofing materials. DO NOT over tighten lag screws, this may compro- mise their holding strength. Slide hook into desired position within valley of the Carefully clean the underlayment then apply bead of Flashing must be sealed to ded tile. The hook must not overhang the side edges of sealant compatible with roofing materials in the shape method with mastic and mesh, s1 the base plate. Drive self -tapping screw to secure of an upside down U on the backside of the sub -flash- layment bibbing. When bibbing, tl hook to base using a 18 Phillips drive bit. Do not ing, see example on page 2, and install flashing over mount. Fasten sub -flashing to deck with one roofing bib should extend 3" under the ment above the flashing and the use impact gun on screw. nail in each top corner. Do not nail bottom corners. enough to overlap the sides of the Cut a clearance notch in the weather guard lug Bolt the side -mounted rail of your choice to the using a grinder with tuck point blade. Makesure the hook, using the rail manufacturer's hardware. the seats back down in it's original position. Leave at least I/a" of tile to prevent breaking through. BI 7.2.3-34 1 ■U i�uildi the FOR - 11 Mar-2015, Rev 5 FOOTING SPECIFICATIONS CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www.cleansolar.com ;, 1 H OC W m a OTC � CM um Cm Id�ai1 W C M CM N -cc CIO DiPaEz W Q. C=O rCIO 20 �Wo O ODE �JMPLIANC T N= A4�� H- U Lil O ry n DRAWN BY: JPH DATE: 2/24 16 REV: 2/26/16 SHEET NUMBER: Z-003 AwAk ,ZAk IRON RIDGE XR Rail Family I XR Rail Family Solar Is Not Always Sunny Over their lifetime,. solar panels experience countless extreme weather events. Not just the worst storms in years; but the worst storms in 40 years. High winds.capable of ripping panels from a roof, and snowfalls -weighing enough to buckle ,a panel frame. XR Rails are the structural backbone preventing r j these results. They resisf;uplift, protecthis, A ` against buckling and safely -and efficiently' transfer loads into the building structure. ;T c- Their superior spanning capability requires fewer roof attachments;. - - reducing the number of`roof ; penetrations and the amount of installation time. =a Force -Stabilizing Curve Sloped roofs generate both vertical., and lateral. forces,on mounting rails which can cause them. 'to bend and twist. The curved shape of :XR Rails is specially designed to increase strength in both directions while resisting the twisting. This unique feature ensures greater security during extreme weather and a longer system lifetime. Compatible.with Flat & Pitched Roofs XR Rails are IronRidge offers compatible with ® , a range of tilt leg FlashFoot and options for flat ® .other pitched roof ® roof -mounting attachments. applications. Corrosions -Resistant Materials All XR Rails are made of marine -grade, aluminum'alloy, then protected with an anodized finish. Anodizing prevents surface and structural corrosion; while also providing a.more -attractive appearance. The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. XR10 XR10 is a sleek, low -profile mounting rail, perfectly matched to regions without snow. It achieves 6 foot spans, while also staying light and economical. • 6'spanning capability • Moderate load capability • Clear anodized finish • Internal splices available Rail Selection XR100 XR100 is the ultimate residential mounting rail. It supports a range of wind and snow conditions, while also maximizing spans. • 8'spanning capability • Heavy load capability • Clear & black anodized finish • Internal splices available XR1000 XR1000 is a heavyweight among solar mounting rails. It's built to handle extreme climates and spans 12 feet or more for commercial applications. • 12' spanning capability • Extreme load capability • Clear anodized finish • Internal splices available The following table was prepared in compliance with applicable engineering codes and standards. Values are based on the following criteria: ASCE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed span tables and certifications. CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www.cleansolar.com L1EANJQLA 1-- W m O N N c LAJ Q O" V Ica C.2 Z a z c Q �c~co N v N � I ti V ng D artm4:9 0 % ➢016 C'03 � COE E COMPLIANCE 3y: ' U w O DRAWN BY: JPH DATE: 2/24/16 REV: 2/26/16 j SHEET NUMBER: RACKING SPECIFICATIONS Z-0 04.1 S_ Carling Madison Lofquist, Inc: Consu_l,trn.g St•;ructui'a! a -rid F.6.rensrc :E'ngrneers .h� 5224'South 391h Street, Phoenix, Arizona 85040 tel: (602) 438-2500 fax: (602) 438-2505 ROC#291316 www.smleng.com IronRidge December 18, 2014 1495 Zephyr Ave Page 1 of 20 Hayward, CA 94544 Attn: Mr. David F. Taggart, Vice President Products Subject: IronRidge XR10 Rail, Roof Flush Mounting System — Structural Analysis Dear Sir: We have analyzed the IronRidge XR10 Rail for the subject solar module support system and determined that, for the configurations and criteria described below, it is in compliance with the applicable sections of the following Reference Documents: Codes: ASCE/SEI 7-10 Min. Design Loads for Buildings & Other Structures California Building Code 2012 Edition Other: AC428, Acceptance Criteria for Modular Framing Systems Used to Support PV Modules, dated Effective November 1, 2012 by ICC-ES Aluminum Design Manual, 2010 Edition The IronRidge XR10 Rail is an extruded aluminum section with an overall depth of 1.75 in. and a net area of 0.363 sq.in. The rails are used to support solar modules, typically, on the roof of a building. See Exhibit A — attached. The rails are clamped to aluminum angle brackets that are either attached directly to the roof framing or attached to a stand that is screwed to the roof framing. The rails are mounted across the slope with a small clearance (flush mounting) to the underlying roof structure. The installed solar modules are at the same slope as the underlying roof structure. All loads are transferred to the roof framing through the angle brackets by simple bi-axial flexure of the rails. The maximum span of the rails is governed by either the mid -span flexural stresses or the deflection requirement that the rail not come into contact with the roof. The effect of seismic loads (for all design categories A-F) have been determined to be less than the effect due to wind loads in all load conditions and combinations. Therefore, the maximum allowable spans for common load cases are shown in the tables below. Tables IA-9A are for modules with a maximum long dimension of 67.5 inches and Tables 1 B-9B are for modules with a maximum long dimension of 78.5 inches. Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers IronRidge December 18, 2014 Mr. David F. Taggart Page 5 of 20 IronRidge XR10 Rail, Roof Flush Mounting System Structural Analysis Table 4A - MAXIMUM SPANS (in) - Roof Slope 70 to 270 - Wind Zone 1(67.5" Max Module Length) XR10 Rail Wind Speed Ground Snow Load Exposure mph 0 psf 10 psf 20 psf 30 psf 40 psf 50 psf 60 psf 70 psf 80 psf 90 psf 100 75 65 55 49 43 39 35 33 31 29 105 75 65 55 49 43 39 35 33 31 29 110 75 65 55 49 43 39 35 33 31 29 120 75 65 55 49 43 39 35 33 31 29 Category ory 130 75 65 55 49 43 39 35 33 31 29 140 71 65 55 49 43 39 35 33 31 29 150 66 65 55 49 43 39 35 33 31 29 160 62 62 54 48 43 39 35 33 31 29 170 59 1 59 53 47 1 43 39 35 33 31 1 29 100 75 65 55 49 43 39 35 33 31 29 105 75 65 55 49 43 39 35 33 31 29 110 75 65 55 49 43 39 35 33 31 29 120 70 65 55 49 43 39 35 33 31 29 Category 130 65 64 54 48 43 39 35 33 31 29 C 140 60 60 53 48 43 39 35 33 31 29 150 56 56 52 47 43 39 35 33 31 29 160 53 1 53 51 46 42 39 35 33 31 1 29 170 50 50 50 45 1 41 38 35 33 31 29 100 75 65 55 49 43 39 35 33 31 29 105 73 65 55 49 43 39 35 33 31 29 110 70 65 1 55 49 43 39 35 33 31 29 120 64 64 54 48 43 39 35 33 31 29 CateDgory 130 60 60 53 47 43 39 35 33 31 29 140 55 55 52 46 42 39 35 33 31 29 150 52 52 50 46 42 39 35 33 31 29 160 49 49 49 45 41 38 35 33 31 29 170 46 1 46 46 44 1 40 37 35 33 1 31 29 Notes - see page 20 f��wF^hy:i CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www.cleansolar.com LF�P1►1`�lS6LAR F— CC W O o- = -o N N L' Q co o ��Lo _v w a W Q co �-- Go -� W G. w CMO- v C0 � O Z C UII aD RTiBUilej�a(tillefl� NAR 1112 2016 REVIEWED FOR Reviewed By Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers -5- RACKING ENGINEERING 1 bE COMPLIANC DRAWN BY: JPH REV: SHEET NUMBER: Z-004.2 Iron.Ridge December, 1:8_ 201.4 1GIr.'DavidV,, Taggart Page.20,6f,2.0. IronRidge XRl`0. Rai1,;Roof;Flush'Mounting; System—:S:tructural Analysis Notes; —Tabulated: values are based.onthe following; criteria; Buildingmean roof heigbt= 30.ft 2., Risk Category I 3`. _ Solar maximum.miod'ulej long_duriens on is.67.5 inches for. Tables :1A=.9A'and 78:5:inches for Tables IB 9B. 4i Provide 2 M clear between roof and rail 5. End cantilever span (max) = 0 4..0 x maximum man from above 'tables 6: No rail: splices yin .end spans. 7. Nor splices':in middle .1/3 of'inietior spans 8. $inglesimple spans}: Spansaiste-d.m. tlie'tables above may be multiplied by 1.08 for continuous rails of 3" or more- spans, Our analys><s' assumes that the ;rail`s, including : e connections and. associated hardware,. are installed; in a workmanlike manner .in atcordane6 with the " IroriRidge..Roof Mount TnstalIation:MAnual" by 'IronRidge: and .generall: accepted standards. oficonstruction:practice AdditioriaI information is - favailable atthe RonRid a web, site IronRid ecom VionoPaModule: ca a.cttY to support,. t. ated with- the: bethe,responliy:ftieotacor. andtheloadsassocivItCOwner noflronRidgo�orlStarling Madison Lofquist.: The ,ad .quacy-of the supporting roof framing -,is to be determined by.others. Please -feel .free to, coritactme at, -your :convenience if you have any .questions.: Respectfully- yours,.. Tres Warner, Design Division Manager a W All 1 C71973 EXR sr CtVfu .. ��Q''CA� staling Mad son.Lofqu st; Inc: .Consulting Structura1and.F-4ensic Engineers 20 RACKING ENGINEERING 2 25800 Commercentre Drive Lake Forest, CA 92630 USA Telephone: 949.448.4100 Facsimile: 949.448.4111 www.intertek.com Test Verification of Conformity In the basis of the tests undertaken, the sample(s) of the below product have been found to comply with the requirements of the referenced specifications at the timerthe tests were carried out. Applicant Name & Address: Product Description: Ratings & Principle Characteristics: ,Models: Brand Name: Relevant Standards: Verification .issuing Office; Date of Tests: Test;Report'Number(s): This verification is part rbf tl imply product certification. IronRidge, Inc. -- 1495 Zephyr Ave. Hayward CA 94544 XR.Rails with -Integrated Grounding. Fire Class Etesistance Rating: Class A.for Steep Slope Flush -Mount (symmetrical) Applications when using 6rype."1 and Type1, Listed Photovoltaic Module. . Class A'for Low'slo a Flush,Mount and Tilt -Mount (symmetrical and asymmetrical) Applications when using Type 1,. Listed Photovoltaic module,. 51-61GD-005,,,51-61GD-005B,51-5000-001, and 51-65-001 N/A UL Subject 2703(Section '15.2 and 15.3) Outline of Investigation for Rack Mounting'Systems and Clamping Devices,for Flat-Plate�Photovoltaic Modules and Panels,, Issue Number:,2, Nov;13,2012 Referencing UL1703 (Section'31.2) Standard for Safety for Flat -Plate Photovoltaic Modules and Panels, May 20, 2014, Intertek Testing Services- NA,. Inc. 25800 Commercentre.Dr. Lake Forest, CA 92630 08/27/2014 to'01/07/2015 101541132LAX-002 , Completed by: AmarKacel Title: P.0 Engineer Signature: y ( Dater 01/26/2015 reports) :be read in.conjunction with them: Reviewed bye Andrew Koretoff Title: Reviewer 'Signature: a �j{-- Date: 01/-26/2015 report does rw,5 C U 1 e All R C( Reviewed By: This Verification is for the exclusive use of intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product or service is or has ever been under an Intertek certification program. GFT-OP-11a (24-MAR-2014) RACKING FIRE RATING CLEAN SOLAR INC. 1445 KOLL CIRCLE., SUITE 109 San Jose, CA. 95112 Cont. Lic # 910849 www.cleansolar.com CLEAI'VSOLAR W m a = -mr � ��� N o W V CP � N Z azr` W LL3 O d WCEO N d v Cn V 0 V Z COO _ INO artment III •PLIANCE DRAWN BY: JPH DATE: 2/24/16 REV: 2/26/16 SHEET NUMBER: Z-004.3 A►. IRON RIDGE Integrated Grounding System I Installation Overview Simplified Grounding For Greater Safety & Lower Cost Traditionally, solar modules are grounded by attaching lugs, bolts or clips to the module frame, then connecting these to a copper conductor that runs throughout the array. This process adds time and cost to the installation, and often results in improper grounding, creating significant long-term safety risks. The IronRidge Integrated Grounding System solves these challenges by bonding modules directly to the mounting rails. This approach eliminates separate module grounding hardware, and it creates many parallel grounding paths throughout the array_, providing greater safety for system owners. 2. � -1 - - . �' Grounding Strap Grounding Straps are used to bond. rail -to -rail connections. They are only required on the rail with the grounding lug. Install Roof Attachments CLEAN • Install appropriate roof flashing and/or standoff for roof type. SOLAR INC. AM7 1 1445 KOLL CIRCLE., • Attach L-Feet to flashing or standoff. SUITE 109 i _ _ San Jose, CA. 95112 Grounding Mid Clamp Each Grounding Mid Clamp pierces through the anodized coatings of both thamodule-frame and the, -mounting rail to form:secure electricaLbonds, which are'repeated throughout the array. 3 % ,W Grounding Lug A single Grounding Lug connects an entire row' of PV modules toathe, grounding conductor. io Prepare Rail Connections L&1-)R,I I Cont. Lic # 910849 • Insert splice into first rail, then secure with Grounding Strap and self -drilling screw. • Slide second rail over splice, then secure with opposite end of Grounding Strap and self -drilling screw. Mount & Ground Rails • Attach rails to L-Feet and level rails. • Install one Grounding Lug per row of modules. • Connect Grounding Lug to grounding conductor. 53 Install Modules & Clamps • Install first module using End Clamps and Grounding Mid Clamps. • Install additional modules using Grounding Mid Clamps. • Finish row with a second pair of End Clamps. Testing & Certification The IronRidge Integrated Grounding System has been tested and certified to UL 2703 by Intertek Group plc. UL 2703 is a proposed UL standard for evaluating solar module mounting and clamping devices. It ensures these devices will maintain strong electrical and mechanical connections over an extended period of time in extreme outdoor environments. The testing process closely mirrors that of UL 1703, the solar module testing standard, including temperature and humidity cycling, electrical and mechanical load testing, and manufacturing quality reviews. 6 l a] Module Frame Compatibility A Any module frames whose parameters are not listed In the provided table have not been tested for compatibility. Ll- E; y U C The Grounding Clamp has proven robust in ground66-6eilland 72-cell solar module frames with box construction >,;da, rang$ of ; anodization thicknesses. All solar modules listed to UL 1703 and with frame [RCHQ'gr[O4 --tD FO within the parameters stated above are compatible with the IronRidge Integrated Grounding System. Reviewe :J Go to ironrdge,corn/ig Dimension Range A 31.Omm - 51.Omm B 5.08mm (minimum) j P F ling RC By: GROUNDING 5 BONDING SPECIFICATIONS www.cleansolar.com OW, IVQ`1! 10~C W m C- .Cr M �y=� W W C� CM7 N �'CO Q N Cz � azr` 0 ' l� CL. w N CL �� Cn ® C.2 Z Q TI Nr partment 2016 10 COMPLIANCE DRAWN BY: JPH DATE: 2/24/16 REV: 2/26/16 SHEET NUMBER: Z-005 SIMME I CARBON A40NOXIDE ALARMS OWNER CE"'IFICATEE, OF COMPLIANGE, COMMUNITY05-VtLOPT1ENT DEPARTMENT- BULDING DIVISION 10300 TORRE AVIiNUE,a CCUPERTWO, to 4-325'-5 (4,08) -32284!rAXj408)7-777,33S, buildiijoe—m-polkip-om 7TI-" � Address Pj�J30S, Tbis afWa is a selfcerfification for the in8tallation of all xequi-Te-d Smokean4i Carbon Moroxide AIM MS fQj- couipffimice vviffi:2013 CRC Section R314,, 2013, C-B C , -Sections 420.6 and 90 7.2.112 wher'e DO illtehdt aUeSS f0T inspctiom are re-quiro-d- GE,�ERAiiNFmmkwrioN Fbisfai,g single-f arnfly, and multi-f-amily- dvvellm'gs 4-iall be provided with, Smoke A.Imms and. Carbon dureffingunits exceeds $1000-00, CRC Section R314.wncl CBCSections,90.2.11.5 and 4W.6 and/or Cftfbon 'Monoxide Alw-xnabe stalled in the following locations: AREA W OKE ALAOT. CO ALARM Outside 011'each separat� ' Iftping aTea in the inun-edlate- vidnity of the X X 1 On f ikyery' le�vel o a dwelIN'unit in�luqL7% basenigAts X VV' 3' lift each 10 q g 190in Cafbon Monoxide alarms are not te d dNvelli-np -M-d0i idc�-nqt cantain fvel�-burnyfttg a ' d" quire, in pp amice4 at don t have an attac CBC Section 420.6 acid :shad be appmovedby file offic oftheStattiFirzMaxshal. oweT supp ro-,,v,er',"3upply.Indwehing:un-i-i --wthno oannierdalp ly, "ar-tn(s)mkvlie-solelybatteryo'peratp-J- not xesTult in the re.-no-val of vvaU and ceirmg-ftishes -or there is, no access means of attic, basement or crawl space- Refer I-o CR' Secdoo R314 .and CT 15'ectfains 90721.1A and,420.6.2. An electrical pem-dt is required for alam -v,; ivfdch must be comlected to the bufldfiv' A."rinla". Asolvne.r*f the above-ieferenced prQpeTty, Ibereby ceirtify ffiat been instalIed in aixordanoe with the, manufactuTer's instruclimi-s mid in com va. th rraa the:talffb I Building and Calffonija Residential Cbdes-Th� apd,arebperztjql, asof the date signed ,I 178ve Me a e to cvipj 1111M fhaiarrj)&-and �6rfdilfOng of thft sloteMent Contractor Niamv. q ......... Date, Swbh, 4nd CQf&-h%.,I00 WATER -CONSERVING PLUMBING FIXTURES OWNER CERTIFICATE OP COMPLIANCE Eig COMMUNrNDEVELOPMENT DEPARTMENT - BUILDING DIVISION CUPERT11WO 10300 TORRE AVENUE - CUPERTINO, CA 95014-3255 tAWIF1777 8 A;3 OwnerName FAX (408) 777-3333 - buildingaCupertino .oEg Permit No. Address 1. Is your real property a registered historical site? n O(Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. No Go to Question 2. 2. Does your real property have a licensed plumber certifying that due to the age or configuration of the property or its plumbing, installation of water -conserving plumbing fixtures is not technically feasible? 0 Yes Civil Code Sections 1101.1 through 1101.8 do not apply. 0 The licensed plumber's certification has been provided to the Building Division. Skip the rest of the forni and sign bottom of form. No Co to Question 3. 3- Is water service permanently disconnected for your building? 0,JYes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. 2"No Co to Question 4. 4. Is your real property built and available for use or occupancy on or before January 1, 19947 Cl No My real property inbuilt and available for use or occupancy after January 1, 1994. Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. Yes My real property is built and available for use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101.8 apply. Check one of theithree following statements and sign bottom of form.. S. PlOase check ONE of the following: MY Property is a single-family residential real property. See Civil Code Section 1101.4. On and after January'l, 1014, building alterations or improvements, shall 4 require all non -compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non- compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements). 0 My property is a multifamily rWdential real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building ilding alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. Ing On or before January 1, 2019, all noncompliant plumbing fixtures shall be replaced with water - conserving plumbing fixtures throughout the building (regardless of whether property -undergoes alterations or improvements). 0 My property is a commercial real property See Civil Code Section 1101.5. On, and after January 1, 2014, specified building alterations or improvemefttg shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non -compliant plumbing fixtures shall be replaced with water- conserving. plumbing fixtures throughout the building (regardless ofwhether property undergoes.alterations or. improvements). L as the owner or owner's agent of this property, certify under penalty of perjury that non -compliant plumbing fixtures will be replaced prior to date specified above with water -conserving plumbing fixtures in accordance with Civil Code Sections 1101.1 through 1101.8, the current California Plumbing Code and California Grew Building Standards Code, and manufacturer's installation requirements, and that the water -conserving I tubing fixtures comply with the requirements as indicated it the 9P u%1 Ing table on the following uaae. .09 /_ ^, F -, # e I r10 completing and signing this Certificate, P "as e7turn it to the Building.ivision in order to final your SB40720151doc revised 0,W645