B-2016-1456CITY OF CUPERTINO BUILDING PERMIT
BUILDING ADDRESS:
CONTRACTOR:
PERMIT NO: B-2016-1456
22465 PALM AVE CUPERTINO, CA 95014-2711 (357 03 068)
( CLEAN SOLAR INC)
SAN JOSE, CA 95112
OWNER'S NAME: SANTOS ROBERT J AND JANICE C
DATE ISSUED: 03/02/2016
OWNER'S PHONE: 408-725-8273
PHONE NO: 408-217-8876
LICENSED CONTRACTOR'S DECLARATION
BUILDING PERMIT INFO:
License Class C-10. C-46 Lic. #9 0849
Contractor ( CLEAN SOLAR INC ) Date 03/02/2016
X BLDG —ELECT —PLUMB
MECH X RESIDENTIAL COMMERCIAL
I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing
with Section 7000) of Division 3 of the Business & Professions Code and that my
license is in full force and effect.
JOB DESCRIPTION:
INSTALL (N) ROOFTOP MOUNTED SOLAR PV (3.45KW) - 10 PANELS
I hereby affirm under penalty of perjury one of the following two declarations:
1. I have and will maintain a certificate of consent to self -insure for Worker's
Compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
2. I have and will maintain Worker's Compensation Insurance, as provided for
by Section 3700 of the Labor Code, for the performance of the work for which
Sq. Ft Floor Area:
Valuation: $20007.00
this permit is issued.
APPLICANT CERTIFICATION
I certify that I have read this application and state that the above
information is correct. I agree to comply with all city and county
APN Number:
Occupancy Type:
ordinances and state laws relating to building construction, and hereby
35703 068
authorize representatives of this city to enter upon the above mentioned
property for inspection purposes. (We) agree to save indemnify and keep
harmless the City of Cupertino against liabilities, judgments, costs, and
PERMIT EXPIRES IF WORK IS NOT STARTED
expenses which may accrue against said City in consequence of the
WITHIN 180 DAYS OF PERMIT ISSUANCE OR
granting of this permit. Additionally, the applicant understands and will
comply with all non -point source regulations per the Cupertino Municipal
180 DAYS FROM LAST CA L I SP
Code, Section 9.18.
/
Issued by: ALEX VALLELUNGA
Sign tiara Date 03/02/2016
Date: 03/02/2016 i
OWNER -BUILDER DECLARA
RE -ROOFS:
I hereby affirm that I am exempt from the Contractor's License Law for one of the
All roofs shall be inspected prior to any roofing material being installed. If a roof is
following two reasons:
installed without first obtaining an inspection, I agree to remove all new materials for
1. I, as owner of the property, or my employees with wages as their sole
inspection.
compensation, will do the work, and the structure is not intended or offered
for sale (Sec.7044, Business & Professions Code)
Signature of Applicant:
2. I, as owner of the property, am exclusively contracting with licensed
Date: 03/02/2016
contractors to construct the project (Sec.7044, Business & Professions Code).
I hereby affirm under penalty of perjury one of the following three declarations:
ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER
1. I have and will maintain a Certificate of Consent to self -insure for Worker's
Compensation, as provided for by Section 3700 of the Labor Code, for the
HAZARDOUS MATERIALS DISCLOSURE
performance of the work for which this permit is issued.
I have read the hazardous materials requirements under Chapter 6.95 of the
2. I have and will maintain Worker's Compensation Insurance, as provided for
California Health & Safety Code, Sections 25505, 25533, and 25534. I will
by Section 3700 of the Labor Code, for the performance of the work for which
maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the
this permit is issued.
Health & Safety Code, Section 25532(a) should I store or handle hazardous
3. I certify that in the perfonnance of the work for which this pen -nit is issued, I
material. Additionally, should I use equipment or devices which emit hazardous
shall not employ any person in any manner so as to become subject to the
air contaminants as defined by the Bay Area Air Quality Management District I
will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and
Worker's Compensation laws of California. If, after making this certificate of
the Health & Safety Code, Se tions 25505, 25533, and 25534.
exemption, I become subject to the Worker's Compensation provisions of the
Labor Code, I must forthwith comply with such provisions or this permit sha
�n
l�wnur o r autborieze a ,, et7
be deemed revoked.
Date: 03/02/2016
APPLICANT CERTIFICATION
CONSTRUCTION LE DI A E CY
I certify that I have read this application and state that the above information is
I hereby affirm that there is a construction lendin6agellcy for the performance
correct. I agree to comply with all city and county ordinances and state laws
of work's for which this permit is issued (Sec. 3097, Civ C.)
relating to building construction, and hereby authorize representatives of this city
Lender's Name
to enter upon the above mentioned property for inspection purposes. (We) agree
to save indemnify and keep harmless the City of Cupertino against liabilities,
Lender's Address
judgments, costs, and expenses which may accrue against said City in
consequence of the granting of this permit. Additionally, the applicant
ARCHITECT'S DECLARATION
understands and will comply with all non -point source regulations per the
I understand my plans shall be used as public records.
Cupertino Municipal Code, Section 9.18.
Licensed
Professional
Signature Date 03/02/2016
ALTERNATIVE. ENERGY PERMIT APPLICATION
COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION AE
10300 TORRE AVENUE • CUPERTINO, CA 95014-3255
(408) 777-3228 • FAX (408) 777-3333 • buildingaa cupertino.org
CUPERTINO
p'7 —0-3 _ M
PROTECT ADDRESS � � I r /� I APN 357
CwN,ER NAmQ CM v�l 2a t n I
PFf • . " Z6 - UZ l J
-
E-MAILI f 2�� I �, / � C`'� l
STREET ADDRESS
22,L f / � A`n ( ^ „Ave
CITY, STATE, ZIP J �j y�� I �} 61 r !
kqy
FAX i
-,
CONTACT NAME3
/
PHO -I
E-T4AIL -
!
J (� u� (�
Z I •(J&t `•
STREET ADDRESS,2,W f� /l
CITY, STATE, ZIP C I � r t (
FAX
eOWNER. ❑ 01V1`cR-BUIIAER ❑ OWW-TR AGENT ❑ CONMIL+CTOR ❑ CONTi R4CTOR AGRN7r ❑ .A.RC=.CT ❑ ENGINEER ❑ DEVELOPER ❑ TFNAN r
CONTRACTOR NAME 6�
LICENSE NL11BEPR tn
LICENSL� E�
BUS. LIC n
COMPANY NAME
E-MAIL l�I
FAX
STREET ADDRESS 140 �� t� ``� ` ( y� , D (��
CITY, STATE, ZIP��
ARCHITECT/ENGI.NIEER NAA4E
LICENSE NUA4BER
I BUS. LIC R 3
COIVQPANY NAME
E-MAIL
FAX
STREET ADDRESS
CITY, STATE, ZIP
PHONE
USE of SFD or Duplex ❑ Multi -Family
PROJECT IN WILDLA1\1D
PROJECT IN
STRUCTURE: ❑ Commercial
URBAN INTERFACE AREA ❑ Yes �:No
FLOOD ZONE ❑ Yes ❑' NO
SOLAR PANELS
❑ ELECTRIC VEHICLE CY ARGING STATION
❑ SOLAR WATER FMATING
❑ OTHER:
FOR SOLAR PAA'ELS. NUMBER OF PANELSIMNITS: KILOWATTS (COMMERCIAL ONL i7:
TOTAL VALUAT
DESCRIPTI01,' OF WORK /O C-_VIar n w1 0_
5
• • •
RECEIVED BY ' "_ � � R 4 S -
By my signature below, I certify toeach of the following: I am the property owmer or authorized agent to act on the property owner's b half. I ha
application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply With all applicable local
ordinances and state laws relating to. uildin-g construction author'7e representatives of Cupertino to enter the ab Pe -id n]1tified property for inspection purposes.
n � C S ignature of Applicant/Agent: f Date:
SUPPLEMENTAL 12\U6ATIP9 REQUIRED
OVERTH)rCOUI�T•EE r t-
� ❑ .-. � r ,t
3
SG.
- �
Pi!4pp_2011.doc revised 03116111
LABELS WILL BE ENGRAVED PLASTIC, WEATHER RESISTANT, RED WITH WHITE LETTERING, MIN 1 /2" HIGH LETTERING
At the Main Service Panel
• .. BREAKER 705.12(D)(7)
To be installed at the Main Service Panel:
WARNING: DUAL POWER SOURCES
SECOND SOURCE IS A PHOTOVOLTAIC SYSTEM
WARNING: ELECTRIC SHOCK HAZARD - DO NOT
TOUCH TERMINALS - TERMINALS ON BOTH THE LINE
AND THE LOAD SIDES MAY BE ENERGIZED IN THE
OPEN POSITION
MAX AC OPERATING CURRENT: 12.5 A
NOMINAL OPERATING AC VOLTAGE: 240 V
.•• .
iWWI 44011W P
2.
To be installed at the junction boxes:
3.
To be installed at the DC disconnect (inverter -integrated):
9
To be installed on the Inverter:
MAX AC OPERATING CU-- 5.
NOMINALOPERATING AC VOLTAGE:40
CEC 690.54 & CEC 705.12(D)(4)
To be installed at the AC Disconnect:
CAUTIONPHOTOVOLTAIC AC DISC
CEC 690.14(C)(2)
Buildings with utility services and a PV system shall have a plaque
or directory indicating the location of the service disconnecting
means and the PV system disconnecting means
A 1
'.
i Q
a 1
-
2246&"Pahn:Ave
;a;
L
_j
`"
r
_Palm Ay
NTS
VICINITY MAP
LABELS
ALL MATERIALS, EQUIPMENT, INSTALLATION AND WORK
SHALL COMPLY WITH CEC ARTICLE 690
DC WIRING METHODS SHALL NOT BE INSTALLED WITHIN
10" OF THE ROOF DECKING OR SHEATHING EXCEPT
WHERE COVERED BY THE PV MODULES AND EQUIPMENT
LICENSE HOLDER'S
SIGNATURE
(CEC 690.31(E)(1))
AN ACCESS POINT SHALL BE PROVIDED THAT DOES NOT
CLEAN
SOLAR INC.
PLACE THE GROUND LADDER OVER OPENINGS SUCH AS
WINDOWS OR DOORS ARE LOCATED AT STRONG POINTS
1445 KOLLCIRCLE.,
OF BUILDING CONSTRUCTION AND IN LOCATIONS WHERE
SUITE 109
San Jose, CA.95112
THE ACCESS POINT DOES NOT CONFLICT WITH
OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES,
Cont. Lic # 910849
OR SIGNS (CRC R331.4.2)
ALL EQUIPMENT AND ASSOCIATED CONNECTIONS OF
www.cleansolar.com
INVERTERS, MODULES, PV SOURCE CIRCUITS, BATTER
CONNECTIONS, ETC. AND ALL ASSOCIATED WIRING AND
INTERCONNECTIONS SHALL BE INSTALLED ONLY BY
QUALIFIED PERSONNEL (CEC 690.4(E))
ELECTRICAL RUN IS APPROXIMATE AND WILL BE�.EA�``lr.�?4R
DETERMINED IN THE FIELD BY OUR ELECTRICAL
INSTALLERS
INSTALLATION OF G-001
(10) SUNPOWER SPR-X21-345-WHT MODULES
& (10) SOLAREDGE P400 DC -DC OPTIMIZERS
& (1) SOLAREDGE SE-300& WOlR9�WEUOPMENT .DEPARTNIE f-001
STC RATING: 3.45 KW BU.ILD,ING DIVISION - CUPERTINO
CEC RATING: 3.1 KW APPROVED FS101
This, set of plans and specifications MUST be kept et th` 201
OCCUPANCY TYPE: Rlob`site during construction. It is unlawful to -make
CONSTRUCTION TYPE: Ohbnges or alterations on same, or to.devi to
AHJ: CITY OF CUPERTINI %refrom. without approval from the Building Offi ial.
APN: 357-03-068 Th.e:Stamping of this plan and specifications SHALL 0f-601
PROJECT VALUATION: L 2 13_0.Perm.it or to be an approval of the viola iol-602
of an , ovisions of any City Ordinance or State L w.
BY. W�j
Z-001 +
D.AT E-
PERMIT"O�
SCOPE OF WORK
P PLANS HECKED BY
DATE 5
PIA KING DEPT
PWRPITINQ
Ioc
W
m
0
o zi CP
SITE PLAN NOTES
H z M Q 9N
co
EaTITLE
Mal,CUI��RTTIN
SHEET; SCOPE OF WOR. Np�i ing Dopart w
y y
SITE PLAN NOTES
`
o
SITE PLAN
Q
REVIEWED FOR CODE CC
PLIAME
ROOF PLAN
Reviewed By: galq
ROOF FRAMING PLAN; ELEVATIONS,
ATTACHMENT DETAILS
U
ELECTRICAL LINE DIAGRAM ..EC
ELECTRICAL CALCULATIONS
SPECIFICATIONS
J 7
DRAWN BY: (JPH
DATE: '2%24/16
�T
Ev: t'026/16
SHEET NUMBER:
0-001
SHEET INDEX
(10) (N) SOLAR MODULES FLUSH -MOUNTED;
PAIRED WITH (10) (N) DC -DC OPTIMIZERS TO BE
MOUNTED UNDER MODULES
PITCH: 18'
AZIMUTH: 180'
TOTAL AREA OF ARRAY: 176 FT2
1ST STORY
CONCRETE W-TILE ROOF
[AL] ROOF ACCESS POINT
FOR ACCESS LADDER
E
SERVICE POINT &
UTILITY METERING
FC-91
JUNCTION BOX
O INVERTER WITH INTEGRATED
DC DISCONNECT
- - - - CONDUIT RUN
— PROPERTY LINE
EQUIPMENT LEGEND
(N) INVERTER + DC DISCONNECT
(E) MAIN SERVICE PANEL
CONDUIT TO BE RUN MIN. 1" ABOVE ROOF
SURFACE AND UNDER EAVES
LICENSE HOLDER'S I I
SIGNATURE
CLEAN
SOLAR INC.
1445 KOLL CIRCLE.,
SUITE 109
San Jose, CA. 95112
Cont. Lic # 910849
www.cleansolar.com
CLEANLAR
CC
W
on
O
o- = er
� ���
N uJ Q N
o L% �cp
LO
C~.2 Z a 2=
G �1 co O
'mr
d � N d v
coo pr d
UP
'TINFO
, , r BuifdIng L
ap@rtmat
MT\Y R
REVIEWED FOR CO
_ E COMPLIANCE
Reviewed By:
0
DRAWN BY: JPH
DATE: 2/24/16
REV: 2/26/16
SCALE:1/8" =14"
SHEET NUMBER:
FS I01
SITE PLAN
Module
Modules in Array
10
Module Weight - LBSm
41
Total Module Weight
410
Module Width - INCHES
41.2
Module Length - INCHES
61.4
Racking
RACKING Ibs./module
5
Total Racking Weight - LBS.
50
Array
Total Array Weight
460
Module Area
17.6
Total Array Area
176
Lbs. / Sq.Ft.
2.62
Number of Vertical Supports
16
,Lbs. per support
28.8
WEIGHT CALCULATIONS
311-611
TRUSSED SPAN 18'-411
FOOTINGS @
MAX. 72" OC
RAFTERS
.1'@ 24" OC
LICENSE HOLDER'S
SIGNATURE
CLEAN
SOLAR INC.
1445 KOLL CIRCLE.,
SUITE 109
San Jose, CA. 95112
Cont. Lic # 910849
www.cleansolar.com
II eteaWsau►R
oc
cm
C�- =
SCALE: 3/32" = 14" 99 Um -L!
LU &i C-3 C-2 C"
a= CP
PARTIAL FRAMING PLAN C6
LU
Mg)
1"J, 'N.." CUPEW C=
0016 --Pg ep, rtmenro
Colo
COMPOSITION
IA0 2
SHINGLE MODULE CLAMP.R 2 V I
IRONRIDGE XR1 0 BLACK RAIL REVIEWED FOR C :COMPLIANCE
30" EAVE OVERHANG QUICK HOOK TILE HOOK Re
LLJ
QUICK HOOK SUBFLASHING
0
RIDGE BEAM 2 x 411 QUICK HOOK BASE PLATE CL
CL
TRUSSED RAFTERS (2) 5/16" X 3-1/2" STAINLESS ►DRAWN BY: JPH
211 x 4" @ 24" OC STEEL LAG BOLTS MINIMUM DATE: 2/2.4/16
2-112" EMBEDMENT REV: 2/26/16
.EXTERIOR WALLS NTS
ELEVATION DETAIL
NTS SHEET NUMBER:
ATTACHMENT DETAIL I S-201
1. MODULES ARE BONDED TO RAIL USING IRONRIDGE INTEGRATED GROUNDING SYSTEM (SEE ATTACHED SPEC SHEET)
2. WHEN UTILIZING THE 120% RULE, BACKFED PV BREAKERS WILL BE INSTALLED AT OPPOSITE END OF THE BUS BAR FROM THE MAIN BREAKER. A PERMANENT WARNING LABEL TO BE INSTALLED PER SYSTEM
SIGNAGE, SHEET G-001
3. THE GROUNDED CONDUCTOR AND EQUIPMENT GROUNDING CONDUCTORS SIZE #6 AND SMALLER SHALL BE IDENTIFIED CONTINUOUS FOR THE ENTIRE LENGTH
4. FOR ALL SYSTEMS OVER 250V, CONCENTRIC AND ECCENTRIC KNOCKOUTS SHALL BE PROPERLY BONDED
5. THE REQUIRED DC GROUNDING ELECTRODE CONDUCTOR SHALL NOT BE TERMINATED AT THE AC SERVICE TERMINAL BAR. THE CONDUCTOR SHALL TERMINATE AT A GROUNDING ELECTRODE
6. TOTAL VOLTAGE DROP: 0.7%
(10) SUNPOWER SPR-X21-345-WHT Modules
paired with (10) SOLAREDGE P400 DC -DC JBox
Nema 3R
OPTIMIZERS wired in series string
[A] Free Air
(2) #10 AWG PV wire
(1) #6 AWG Bare Copper EGC/GEC
(1) SOLAREDGE SE3000A-US-U Inverter
with integrated DC disconnect
— —
— —
— — — — — —
----------------
AC
I
I
I
DC
[B] 1 /2" EMT conduit [C] 1 /2" EMT conduit
(2) #10 AWG THWN-2 Wire (3) #10 AWG THWN-2 Wire
(1) #8 AWG THWN-2 EGC/GEC (1) #8 AWG THWN-2 EGC/GEC
Utility Service
120/240V
EXISTING 125A SERVICE
PANEL TO BE UPGRADED
(SEPARATE PERMIT):
200A Main Meter
200A Main Service Panel
200A Main Breaker
`1
MIK-01
(N) PV OCPD
2P 20A
I VI''
CU
`,
L — — 'Y
p! l�lldi
(N) #4 GROUND ROE "
(N) #4 WATER PIPE
REVIEWED FOR
Reviewed B'
I LICENSE HOLDER'S I
SIGNATURE
CLEAN
SOLAR INC.
1445 KOLL CIRCLE.,
SUITE 109
San Jose, CA. 95112
Cont. Lic # 910849
www.cleansolar.com
LTAI' ,30. AK
W
m
C=
o- GC v
W o cra
N �' Q Cm N
c C-2 m � CP
� Z oQ-zr-
o Q o
d N a w
C= C2
:-RIT
IDepaggent
2 2616
ODE CONIPLIAN
%V'�od
0
ry
n
DRAWN BY: JPH
DATE:
REV:
SHEET NUMBER:
ELECTRICAL LINE DIAGRAM E-601
PV Module Electrical Specs
Sunpower SPR-X21-345-WHT
Maximum Power (Pmax)
345 W
Open -Circuit Voltage (Voc)
68.2 V
Short Circuit Current (Isc)
6.39 A
Max. Power -Point Voltage (Vmp)
57.3 V
Max Power -Point Current (Imp)
6.02 A
Series Fuse Rating
20 A
Inverter Electrical Specs
SolarEdge SE3000A-US-U
Maximum Input DC Voltage
500 V
Maximum Input Current
9.5 A
Nominal DC Input Voltage
350 V
Maximum Output Power
3300 W
Maximum Continuous Output Current
12.5 A
Maximum Efficiency
97.5
Optimizer Electrical Specs
SolarEdge P400
Maximum Input DC Voltage
80 V
Maximum Input Current
12.5 A
Maximum Output Voltage
60 V
Maximum Output Current
15 A
Min/Max String Length
8 - 25 #
Maximum Power Per String
5250 W
System Information
Total Number of Modules paired with DC -DC Optimizers 10
lumber of Optimizer Strings at Inverter 1
lumber of DC -DC Optimizers in Series String #1 10
Values at DC -DC Optimizer (SolarEdge P400)
Number of Modules in Series per Optimizer
1 #
Module Max. Output Voltage (1 x 68.2 x 1.14)
77.7 A
Optimizer Maximum Allowable Input Voltage
80.0 V
Number of Modules in Parallel per Optimizer
1 #
Module Max. Output Current (1 x 6.39 x 1.25)
8.0 A
Optimizer Maximum Allowable Input Current
12.5 A
Values at DC Disconnect
(SolarEdge SE3000A-US-U Inverter)
Max. Power -Point Voltage
350.0 V
Maximum Power -Point Current
9.5 'A
Maximum Voltage
500.0 V
Maximum Current
15.0 A
AC Values at Inverter
Nominal Voltage/Operating Range
211-264 V
Utility Voltage
1201240 V
CEC Efficiency
97.5
Overcurrent Protection (12.5 x 1.25 = 15.625)
20 A
Wire Size Calculations
Wire Section (refer to line diagram)
[A]
[B]
[C]
Min. Ampacity Required
18.8 A
18.8 A
15.6 A
(Opt/Inv Max Current x 1.25)
Conduit Type & Size
FREE AIR
1/2" EMT
1/2" EMT
Wire Size
10 AWG
10 AWG
10 AWG
Wire Type
PV WIRE
THWN-2
THWN-2
Wire Ampacity at 30' C
40 A
40 A
40 A
Wire/Conduit Location
Behind Modules >3"
Roof - Exterior >1"
Exterior
Ambient Temperature
52 OC
36 OC
36 OC
Rooftop Conduit Adder (per
0 °C
22 °C
0 °C
CEC 310.15(B)(3)(C))
52 OC
58 OC
36 °C
Total temperature to derate:
Ambient Temp Correction Factor (per
0.76
0.71
0.91
CEC Table 310.15(13)(2)(A))
Multiple Conductor Adjustment
Factor (per CEC Table
1.0
1.0
1.0
310.15(B)(3)(a))
Wire ampacity after applying
30.4
28.4
36.4
correction factors
Busbar Calcs - 120% Rule
Size of Main Buss 200 A
Size of Main Breaker 200 A
Size of PV Breaker 20 A
200 + 20 <= 200 x 1.2; 220 <= 240,
WUPE. ...
I NO
Building Departmen
�eAR 0 2 2016
REVIEWED FOR CODE COM
Reviewed By:
ELECTRICAL CALCULATIONS
LICENSE HOLDER'S
SIGNATURE
CLEAN
SOLAR INC.
1445 KOLL CIRCLE.,
SUITE 109
San Jose, CA. 95112
Cont. Lic # 910849
www.cleansolar.com
L�4►:N�4I.JkR
1--
OC
W
m
C=
N LAJ Q 09 CV
Jo ED cp
LO
Q Z air-
L U Q CEO l� OHO
6LJ C=
G. w N (Z
003 �,
C= v
H
Q
C/2
U
W
O
IANCE
DRAWN BY: JPH
DATE: 2/24/16
REV: 2/26 16
SHEET NUMBER:
E-602
More than.21%':Efficiency _
Ideal;-forroofs where spate Sat a premium Cir°
wrlere fut(ire:expanslpn'inight-be needed
Maximum Performance
D,'es geed to.deliver the rnost;enecgy in
demanding teal world.conditions;: in partial,
shade and hot rooftcip terhperatutt-.
Premium Aesthetics
SunPowerO S; gni tureTM' Blaclt`X Series, panels
blend `harfrion[ou`sly i cwyb& roof. The most.-
elegant choice for your home:
•Makeon®Solarkells .F.undarnenfaflYbefferl-
-"Engineered for;performance designed for:,durabt ity
Engineered for Peace,"of-Mind
D'esgned_to:deliver:consisterlt; trouble free.
enet gy,over:a.very long,lifetime: 3A
Designed `for .D'urablaity, l
_ I
The:Su'hPowe"r Maxeon S0I"a Cell is.the onlycell ;
built;on a'solid copper. foundation. Virtually
im e`rvious tolthe cori-osion and cracking that, j
degrade Conventional` Panels'3: j
j
Same:excel€entdurabiltty asE>5eries'panels. j
-#1' Rank,in Fraunhofer durability test:?
i
'100%,06wer,maintained'in Aflas 25+
ggmp�. fi' rs[ve Durability test10
Unmatched Performance, Reliability & Aesthetics
X.
SERIES
SIGNATURET" BLACK SPR-X21-345
SPR-X21-335-BLK
Highest Efficiency5
Generate more energy per square foot
X-Series residential panels convert more sunlight to electricity producing
38% more power per panel,' and 70% more energy per square foot over 25
years.' 2.1
Highest Energy Production'
Produce more energy per rated watt
High year one performance delivers 8-10% more energy per rated watt.2This
advantage increases over time, producing 21 % more energy over the first 25
years to meet your needs 3
z 120%
110%
i5
.B t00%
3
p 90%
o_
80%
w 70%
} 60%
era 50 %
0
>J
>9
C
c
r
2.1"%'
SunPower X-Series
3646 more,
year 25
Conventional
_J
5 10 15 20 25
Years
----------- -- -----
Maintains High
Power at High Temps
No Light -Induced p
Degradation l
F(Igh Average Watts- I
/4 Better Low L1ght and
Spectral Response
High -Performance
Anti -Reflective Glass
Sunpower Offers The Best Combined Power And Product
Power Warranty Product Warranty
t00%
95%
SunPower
90%
85%
a0%
75%
0 5 10 15 20 25 0 5 10 15 20 25
Years Years
-Conventional Pancl tinear^warranty ,
More guaranteed power: 95% for first 5 years, Combined Power and Product defect 25 year coverage
-0.4%/yr. to year 25. 7 that includes panel replacement costs...
Electrical
Data
SPR-X21-335-BLK SPR-X21-345
Nominal Power (Pnom)17
335 W
345 W
Power Tolerance
+5/-0%
+5/-0%
Avg. Panel EfficienCy12
21.0%
21.5%
Rated Voltage (Vm )
57.3 V
57.3 V
Rated Current (Im )
5.85 A
6.02 A
Open -Circuit Voltage (Voc)
67.9 V
6&2 V
Short -Circuit Current (Isc)
6.23 A
6.39 A
Max. System Voltage
600 V UL & 1000 V IEC
Maximum Series Fuse
15 A
Power Temp Coef.
-0.30% / °C
Voltage Temp Coe
Vo I T £
- 67.4mV/ C
1 0
Current Temp Coef.
3.5 n-A/°C
REFERENCES:
1 All comparisons are SPR-X21.345 vs. a representative conventional panel: 250W, approx. 1.6 rn ,
153% effidency.
2 Typically 8-10% more energy per watt, BEW/DNV Engineering `SunPower Yield Report"Jan 2013.
3 SunPower 025%/yr degradation vs. 1.0%lyr corn. panel. Campeau, 2. et al. 'SunPower Module
Degradation Rate,' SunPower white paper, Feb 2013; Jordan, Dirk "SunPower Test Report" NREL,
Q1-2015.
4 "SunPower Module 40-Year Useful Life° SunPower white paper, May 2015, Useful life is 99 out of
1 in than power. 00 panels operating at more t d pc e .
5 Highest of over 3,200 silicon solar panels, Photon Module Survey, Feb 2014.
6 1% more energy than E-Series panels, 8% more energy than the average of the top 10 panel
companies tested in 2012 (151 panels,102 companies), Photon International, Feb 2013.
7 Compared with the top 15 manufacturers. SunPower Warranty Review, May 2015.
8 Some restrictions and exclusions may apply. See warranty for details.
9 X-Series same as E-Serles, 5 of top 8 panel manufacturers tested In 2013 report, 3 additional
panels in 2014. Ferrara, C., et al. "Fraunhofer PV Durability Initiative for Solar Modules: Part 2".
Photovoltaics International, 2014.
10 Compared with the non -stress -tested control panel. X-Series same as E-Series, tested in Atlas
25+ Durabillty test report Feb 2013.
11 Standard Test Conditions (1000 WW irradiance, AM 1.5, 251 C). NREL calibration Standard:
SOMS current, LACCS FF and Voltage.
12 Based on average of measured power values during productlon.
13 Type 2 fire rating per UL1703:2013, Class C fire rating per UL1703:2002.
14 See sales person for details.
See httpl/www.sunpower.com/facts for more reference information.
For more details, see extended datasheee www.sunpower.comidatasheets.
Stanclard.tests13
certificationsTests And
UL17Q3;Cfype,2 Flre Rating) IEC 61215, lEC:6:173p;
QLiali � Certs
ISO 9001:2008,.ISO 14001:2004
EHS:Compliance
RoHS,.QHSAS18001:2007, lead-free, REACH'
SVHG155,. RV Cycle
,Sustainabili
Cradle -to Cradle (di "ible-for LEER oints)1 i
Ammonia test
IEC62716
De'sert'test
10,1109/PVSC 2013.67. 4437
`Salt S ra .test
IEC61701 (maximum severity),
PID test
Potential -Induced De radationfree:1000V9
Available listirt "s.
UL, CEC, TUV,;MCS,,FSEC'
Operating
Condit ion And Mechanical Data
Temperature
401F to +1856F (- 40°C to +850C)
Impactresistance.
1 inch'(25mm)'diameter hail at 52 mph (23' mis)
Appearance
. Class A+
Solar Cells
96 Monoc" stalline Maxeon Gen III
Tempered Glass
High transmission tempered Anti -Reflective
junctioiT Box
IP 65, MC4 Com atible.
Weight
41 Ibs (1 &6 kg)'
G5.Frame Wind:'62psf`3000Pa;'305ISg/m?front&faack
Max load
Snow: 125 psf, 461� "Im2 f n�
4
63 Frame- Wind:80 psf 240 `Pal l` 2 ont Via,
Sno Ar.112 psf,- $0. Pad O lglm8f,al d I
Frame
Class! black;anodized (hi
eA�cM45fti
ate ° to MIME
{„%j CPQ¢I
�p1
5ER
9 Del
N
46 1558,mrn 1 51n
[61,3in] �i VIEA - FOR COD
t as mm
62
21ni
R`i,�FRAIGIEPROrILF1
1046 h1m No[ Inv siMountt on pa[@le
[41:2 in] I T-
32 mm [13,in1 LONG SIDE
2Zmm [0.9 iN 51id0.T SIDE
G5 frames have no mounting holes, Please read the safety and installation guide:
Document # 504828'-Rev E /LTR_U5
PHOTOVOLTAIC MODULE SPECIFICATIONS
CLEAN
SOLAR INC.
1445 KOLL CIRCLE.,
SUITE 109
San Jose, CA. 95112
Cont. Lic # 910849
www.cleansolar.com
ctFnNldu►R
W
m
a
=
� LO r`
N
G
L.Li Q 07 CV
`7 n v CP
LO
U
2M 4o.,Z
LLj
Q c 00
d
en
W 'd,
� rr
CM
t/3
y
O
cz
ISO�
tmenr,
y
,OMPLIANCE
aw-aw
U
w
U
Of
a_
DRAWN BY: JPH
DATE: 2/24/16
REV: 2/26 16
SHEET NUMBER:
Z-00 1
solar =s"
SolarEdge Single Phase Inverters
For North America
SE3000A-US SE380OA-US / SE500OA-US / SE6000A-US
SE760OA-US SE1000OA-US / SE1140OA-US
Single Phase Inverters North America
solar =se z. SE3000A- US/ SE3800A-US/ SE5000A-US/ SE6000A-US/
SE760OA-US / SE1000OA-US / SE11400A- US
I SE3000A-US I -SE3900h-,US I -SESOOOA-,US I SEisom-us j SE760OA-US I SE10000A-; US I SE11:400A-US I
Nominal AC Power Output 3000 3800 5000 6000 7600 9980 @ 208V 11400
........ I ................................. ................ ............. I . ....... I ......... ................ ...... I ......... . 1QIPRR49y . ..................
Max. AC Power Output 3300 4150 5400 @ 208V 6000 8350 10800 @ 208V 12000
........ . 5450 @240V ..... ................ .. 1.0950.p
Output "''V, Voltage "M'I'n'."N"o'm"-"M"a'x'.�"*) . .......... * ...... , " * * _✓- - ..... V . Z49Y . ...................
AC
183 - 208 - 229 Vac
... I .. ................. .1, ..............
AC Output Voltage Min.-Norn.-Max.0)
211 - 240 - 264 Vac
...... I ..................................
AC Frequency Min.-Nom.-Max.11)
.........................................
Max. Continuous Output Current
.... I ....... ...........................
GFDI Threshold
. .......... ........ ....................
Utility Monitoring, Islanding Protection,
INPUT
Maximum DC Power (STC)
........................................... .
..Transformer -less, Ungrounded
• .... ax:.InputValt e
...................... .
lilt Nom. DC Input Voltage
S................. I ..................... .
Max. Input Currenell
................ I .......................... .
- _r,.- Max. Input Short Circuit
Current .....
Reverse -Polarity
............ .
..GrRyRq-.Fau.1t.l.s.ol.a.tio.n.De.t.ection .....
Maximum Inverter EfficienRy .......... .
............ I .................
CEC Weighted Efficiency
I. Niehtiim,*e"Power 'Consumption'
.....
USA -GERMANY -ITALY -FRANCE -JAPAN -CHINA -AUSTRALIA -THE NETHERLANDS -ISRAEL www.solaredge.us
CLEAN
SOLAR INC.
1445 KOLL CIRCLE.,
VA SUITE 109
........... San Jose, CA. 95112
VA
..........
.... I ...... ............... . I ............... ................ .. I ............. ........... I ...... ................ .....
V V ✓
............... I ................. I ................ I ................ .................. .................. ..... .....
59.3 - 60 - 60.5 (with H1 country setting 57 - 60 - 60.5) Hz
25 32 I...42 47.5 A .16......
. 6 ... I.... 2 ... I ............ .......... I
12 5
A
............................. I ....................................................................................... ...........
ntry Configurable Thresholds Yes Yes
.....
..... #
Yes
50 0
c
.......
................................................................................................................
325 @ 208V / 350
@ 240V
Vdc
5
1 3
i6
1
18
..........
23
@ 208
. ... ......
45
....
Adc
......9 .........
...............
. 1
30. .
........3............
...
.........................................................................................................................
45
��
......
....................... I ................. I ................
Yes ...........................
I ...............................
...........
600ka Sensitivity
..................
.......
.........
...........
97.5
98
97.5 @ 208V 1
......
1 97.5
................
97.5
97 @ 208V
97.5
%
........ .....
.........
.e. 249y..
1 ................
................
..
< 2.5
< 4
W
AoblITIONIAL FEATURES
Supported Communication RS485, RS232, Ethernet, ZigBee (optional)
' * .... .. . .... ..
Revenue Grade Data, ANSI LY21 6 P*t' I o-n' a' I
I . ...................................... ............ ........................................................................................... ........... ...........
Rapid Shutdown — NEC 2014 690.12 Functionality enabled when SolarEdge rapid shutdown kit Is Installed()
STAN DARDIZIOMPLIANCE:
..Safety ..... I ............................
................ I ............. ULI.74.1.,.U.LI6.99.B,.ULI.998.,.CSA.2.2,2 ..................................
I .... .
........
Grid Connection Standards ........
...
IEEE1547
........ ..................
........ ...
... ......
Emissions
FCC part15 class B
INSTALLATICKSPEICII 01CATIONS
AC output conduit size W
l/ AG ..
. , .
'conduit .
...........................
3/4." minimum /. 1.6-.6.AWG ......... ...............
I ............
. , .
. ... 3/4". minimu.m./.8-3. AWG .....
. .. ,
.......
DC input size /# of strings
3/4�'minimum / 1-2 strings / 16-6 AWG
3/4 / 1-2
" minimum strings /
AWG
Dimensions with Safety Switch
30.5 x 12.5 x 7.2 / 775 x 315 x 184
X x
in/
Weight Safety Switch
51.2/23.2 54.7/24.7 ....
775
..............
x 315 x 260
Mm
I�E RTIN
with
......................................
......................
......... ..................................
................
Natural
convection
......
.......
Kilding
Departn
Cooling
Natural Convection
and internal
Fans (L
fan (user
N.AR.10
2016
...................... .................... .
..........
....................................................... .
. r9plAwOM .........
.....
.
......
..... ..2
Noise *'*.....
", '_, "Temperature, -, ''
................
<25
* ....... .........
......
<50
....... * --- * ..... * .................
dBA
........
fn".'_K6x'.' Operating
-13 to +140 / -25 to +60 (-40 to +60 version availablel")
REVIEWED FOFR`CODE
CC
..qM99 ...................................
...........
I .................... I .........................................................................................
...........
Protection Rating ....... ... .....
..... .
III For other regional settings pleas a cent a ct Solar E d ge supper L
i') A higher current source may be used; the inverter will limit its Input
current to the values stated.
Revenue grade inverter P/N: SExxxxA-US000NNR2 (for 7600W Irwerter:SE7600A-US002NNR2).
Rapid shutdown kit P/N: SE1000-RSD-Sl.
tsr -40 version P/N: SExmM-US000NNU4 (for 760OW [nverter:5E760GA-US002NNU4).
0 Ik To -
INVERTER SPECIFICATIONS
Cont. Lic # 910849
www.cleansolar.com
C=
a
Uj
mr =0 LO C= C.-j
LU Q C"
CX CP
di CaC-5 In
C=L g rC-,j
LAJ co-
co 00
Mr W CD
VQ
c0i
CCIJ
= C-2
Cn
IPLIANCE
0V�
0
ry
n
DRAWN BY: JPH
DATE: 2/24/16
REV: 2/26/16
SHEET NUMBER:
Z-002.1
solar =se
solar =ee z SolarEdgeftwerOptimizer
Module Add -On for North America
CLEAN
P300 / P320 / P400 / P405
SOLAR INC.
SolarEdge Power Optimizer
1445 KOLL CIRCLE.,
SUITE 109
Module Add -On For North America
San Jose, CA. 95112
P300
61)-cell afodu16),
Ono,
(for high -power
60tocell modules)
P400
(for,72 &_96,ceII
modules)
P405
(forthin-film(for
modules)
I NPLIT-
Cont. Lic # 910849
Rated Input DC .Powerll)
Absolute Maximum Input Voltage
(1/OC at lowest ...,.......................m.,p.....,...........
MPPT Operating Range.....................................8-48.
........... ... 300 . I ............ 32q ............ ........... I ....400............ ................405............
48 80 125
.......... 1. .......... ...... .................... ....................-...................
8.-90...................12.5105............
........W ......
Vdc
..
..............
Vdc.......
P300 P320 P400 P405
www.cleansolar.com
Maximum Short CIrcuitCurrent(1sc)
...............................
Maximum
.............. ..: .........................I......
Maximum �iiciency
...............D..C..I.n.p.... ......I...... ......
iq 10
... .......... ................ ...................................
12.5 13.75 12.5
........I....................................
99.5
.......................................................................................................................
Adc
.....
Adc
0 .....
Weighted Efficiency ........
Overvoltage Category
98.8
...... ........ ....... * .............. * ...... * ....... ..
a
....... * ......
Ct"EAK 459LA
OUTPUT DURING OPERATION�(POWER,,6PTIMIZER,CONNECTEDtTO OPERATINO'SOLAREDGE INVERTER)
Maximum qy�p Current
...............
15 .............. .............
....................................... .................... I .....................
.... Adc .....
Maximum Output Voltage-
60 I 85
Vdc
OUTPUT DURING STANDBY (POWER -OPTIMIZER DISCCiNNtCTED:FROM :SOLP�REDGE,INVERTEROR SQLARED.GE- INVERTERDFF)-
Safety Output Voltage per Power
Optimizer
1
I
Vdc
I
T
3 1,
JAN,
OW!
4.
jr,
7 4
PV U
'power optimization at the mod le-leve I
Up to, 25% more energy
Superior efficiency (99.5%)
Mit.igatq's all types of module mismatch loss..es,'from manufacturing Xoleran6e topartiaj,shading
Flexible system design for maximum space utilization
Fast installation with a single bolt
Next generati.on maintenance,withmoddle-level -monitoring
Module4evel voltage:shutdown for installer and,firefighter s:afety
USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA www.solaredge.us
a, i m i m uA n Lj %�.%j ivi r L I M IM I— Q
I
EMC
... .................. ......................
FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3
................................... I ............................................. ............................
.............
�ie ................
IEC621091(class II -,�� U.L.17.41 .............. .................
......................................
........
RoHS
Yes
INSTALLATION SPECIFICATIONS
Maximum Allowed System Voltag�
1000
I .................................................................................
Vdc
..............
.............................. ...
Compatible inverters ....................
............. .......... I .........
. . .
......................... AI.I.S.ol.arE.dg.e.Sin.gl.e.P.ha.s.e a.nd.Th.r.ee.P.ha.se.inverters .... ... .... ..........
. . . .
..............
Dimensions (W x L x H)
128 x 1 52 x 27.5 128 x 152 x 35 128x i52x48/
mm/in
5 x 5.97 x 1.08 5 x 5.97 x 1.37 5 x 5.97 x 1.89
... ...................... ............................
..............
............................. I ..............
Weight ........
.........................................................
.770/1.7 930/2.05 930/2.05
...................................................... .....................
... ............
Input .::..... .
...........................................................................
.MC4 Compatible
..............
Output MTTYpiConnector
................
Double Insulated; MC4 Cof!�po!�e....................................
......................................................... ..........
..............
..qy!pyt Wire .l_ &.t�
* �9
0.95/3.0 1.2/3.9
........................................... ........ ................................................
I
m/ft
..............
.4e41�g Temperature Range .
-40 - +85 / -40 - +185
'C/'F
Protection................ ...
.....
W................................................
NM?
..............
RelativeHumidity .... ...................
.......................... 0-100
................................... ........ ............................................
%
.... ......
Rated STC power of the module. module of up to +5% power
tolerance allowed.
CUPERTI
PVSYSTEIM',DESIGN USING
SINGLE TH REE. PHASE 208W THREE PH
W - � A
Bui ldin,0 Depa
A Z1ULAKtUUC INVERTER
Minimum String Length 8
J Power Optimize s) ...................
Maximum String Length 25
(Power Optimizers)
...................... .............................
..Maximum .Power .pe.r.S.t.r.ing ............ ....... ........ 5250 .....
Parallel Strings of Different Lengths
or Orientations
....... I ...... I ..............................................................
I'l It Is not allowed to mix P405 with P300/P400/Pr,00/P71I0 In one string.
10
.... ..................................... ....
25
.... ..................................... ....
.... ................6000........... ....
Yes
...............................................
18
20
...........
so
....... 12 755 E V-1 -E VV E D- -[�D R - C 0 D E
........................................... <1D
Reviewed BY: lav,
I ...... I ..............
OC-DC OPTIMIZER SPECIFICATIONS
ll—
C=
Cn
Lii C= Cn
LU
QON
23
CP
V CP
CS
LU
C=
LO
Co CIO
C=
ient
DMPLIANCE
uad
LU
0
Of
a_
DRAWN BY: JPH
DATE: 2/24/16
REV: 2/26/16
SHEET NUMBER:
Z-002.2
1r-p
#3 TYPE 1 (PHILLIPS) DRIVE ON SCREW 10
1.50 0
1 0 0
SLIDE TO DESIRED
LOCATION I 0 O
1 0 0
.75
2.50
BOTH SIDES OF SLOT SERRATED
0.39 p
�----- 6.00 --1
IDENTIFYING
MARK ON
QMHLS ONLY
DETAIL E
SCALE 1 : 2
DIMENSION
QMHSS
QMHLS
A
6.57
6.30
B
2.21
1.93
C
1.89
1.60
D
6.27
6.00
ITEM DESCRIPTION QTY. a DO NOT USE IMPACT DRILL ON SCREW
NO.
1 BASE PLATE, QUICK HOOK, 6", 6061-T6, MILL 1 0UICk Mount P`' "
2 LAG SCREW, HEX HEAD, 5/16" x 3-1 /2", 18-8SS 2 TITLE:
3 QUICK HOOK, STANDARD/LOW HEIGHT, VERTICAL, 1.5', 6061 1QMHSS & QMHLS: QUICK HOOKb, MILL 1 FOR SIDE MOUNTED RAILS
4 SCREW, SELF -TAPPING, #12 X 5/8", 18-8SS, MILL 1
UNLESS OTHERWISE SPECIFIED. I SIZE I DRAWN BY: RAD I REV
5 SUBFLASHING, QUICK HOOK, 6" BASE, 9" X 14" X .032", 3003-0, MILL 1 DIMENSIONS ARE IN INCHES
TOLERANCES: A DATE: 1/19/2o15 8
FRACIIONALt 1/8
THE INFORMATION CONTAINED Pl TM DRAWING IS THE SOW PROPERTY OF QUICK MOUNT PV. ANY REPRODUCTION IN PART OR AS DO NOT SCALE DRAWING TWOFLACEDECIMAL t.18
A WHOIE WIIHOUTTHE WRRIEN PERMISSION OFQUICK MOUNT PV ISPROHIBITED. I THREE PLACE DECIMAL t.125 SCALE: 1:8 IWEIGHT. 1.82 SHEET OF
Quick Hook'SS & LS
Instructions for Installing Standard and Low Height Hooks for Side Mount Rails
Installation Tools Required: stud finder, tape measure, utility knife, drill with 7/32" bit, impact drill with 1/2" socket,
caulking gun, appropriate sealant compatible with roofing materials, roofing bar, hand broom, stapler,18" wide piece of
underlayment or materials for 3-course method during deck flashing installation.
Remove the tile at selected location of the mount. Rest the base plate over center of rafter and mark Connect hook to base plate and drive lag screws
Locate and mark the center of the rafter. center of holes. Drill two 7/32" pilot holes and fill into rafter through the two holes to a solid, snug fit.
with sealant compatible with roofing materials. DO NOT over tighten lag screws, this may compro-
mise their holding strength.
Slide hook into desired position within valley of the
Carefully clean the underlayment then apply bead of
Flashing must be sealed to ded
tile. The hook must not overhang the side edges of
sealant compatible with roofing materials in the shape
method with mastic and mesh, s1
the base plate. Drive self -tapping screw to secure
of an upside down U on the backside of the sub -flash-
layment bibbing. When bibbing, tl
hook to base using a 18 Phillips drive bit. Do not
ing, see example on page 2, and install flashing over
mount. Fasten sub -flashing to deck with one roofing
bib should extend 3" under the
ment above the flashing and the
use impact gun on screw.
nail in each top corner. Do not nail bottom corners.
enough to overlap the sides of the
Cut a clearance notch in the weather guard lug Bolt the side -mounted rail of your choice to the
using a grinder with tuck point blade. Makesure the hook, using the rail manufacturer's hardware.
the seats back down in it's original position. Leave
at least I/a" of tile to prevent breaking through.
BI 7.2.3-34 1
■U
i�uildi
the
FOR
- 11
Mar-2015, Rev 5
FOOTING SPECIFICATIONS
CLEAN
SOLAR INC.
1445 KOLL CIRCLE.,
SUITE 109
San Jose, CA. 95112
Cont. Lic # 910849
www.cleansolar.com
;,
1
H
OC
W
m
a OTC �
CM um
Cm
Id�ai1 W C M
CM N
-cc CIO
DiPaEz
W Q. C=O rCIO
20 �Wo
O
ODE �JMPLIANC
T N=
A4��
H-
U
Lil
O
ry
n
DRAWN BY: JPH
DATE: 2/24 16
REV: 2/26/16
SHEET NUMBER:
Z-003
AwAk
,ZAk IRON RIDGE XR Rail Family I XR Rail Family
Solar Is Not Always Sunny
Over their lifetime,. solar panels experience countless
extreme weather events. Not just the worst storms in years;
but the worst storms in 40 years. High winds.capable of
ripping panels from a roof, and snowfalls -weighing
enough to buckle ,a panel frame.
XR Rails are the structural backbone preventing r j
these results. They resisf;uplift, protecthis, A
`
against buckling and safely -and efficiently'
transfer loads into the building structure.
;T c-
Their superior spanning capability
requires fewer roof attachments;. - -
reducing the number of`roof ;
penetrations and the amount
of installation time.
=a
Force -Stabilizing Curve
Sloped roofs generate both vertical., and lateral.
forces,on mounting rails which can cause them.
'to bend and twist. The curved shape of :XR Rails
is specially designed to increase strength in both
directions while resisting the twisting. This unique
feature ensures greater security during extreme
weather and a longer system lifetime.
Compatible.with Flat & Pitched Roofs
XR Rails are IronRidge offers
compatible with ® , a range of tilt leg
FlashFoot and options for flat
® .other pitched roof ® roof -mounting
attachments. applications.
Corrosions -Resistant Materials
All XR Rails are made of marine -grade,
aluminum'alloy, then protected with an
anodized finish. Anodizing prevents surface
and structural corrosion; while also providing
a.more -attractive appearance.
The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific
design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match.
XR10
XR10 is a sleek, low -profile mounting
rail, perfectly matched to regions
without snow. It achieves 6 foot spans,
while also staying light and economical.
• 6'spanning capability
• Moderate load capability
• Clear anodized finish
• Internal splices available
Rail Selection
XR100
XR100 is the ultimate residential
mounting rail. It supports a range of
wind and snow conditions, while also
maximizing spans.
• 8'spanning capability
• Heavy load capability
• Clear & black anodized finish
• Internal splices available
XR1000
XR1000 is a heavyweight among
solar mounting rails. It's built to handle
extreme climates and spans 12 feet or
more for commercial applications.
• 12' spanning capability
• Extreme load capability
• Clear anodized finish
• Internal splices available
The following table was prepared in compliance with applicable engineering codes and standards. Values are
based on the following criteria: ASCE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean
Building Height of 30 ft. Visit IronRidge.com for detailed span tables and certifications.
CLEAN
SOLAR INC.
1445 KOLL CIRCLE.,
SUITE 109
San Jose, CA. 95112
Cont. Lic # 910849
www.cleansolar.com
L1EANJQLA
1--
W
m
O
N
N
c
LAJ Q O"
V Ica
C.2
Z a z
c
Q �c~co
N v
N �
I
ti
V
ng D
artm4:9
0 %
➢016
C'03
� COE E COMPLIANCE
3y: '
U
w
O
DRAWN BY: JPH
DATE: 2/24/16
REV: 2/26/16
j SHEET NUMBER:
RACKING SPECIFICATIONS Z-0 04.1
S_ Carling Madison Lofquist, Inc:
Consu_l,trn.g St•;ructui'a! a -rid F.6.rensrc :E'ngrneers
.h� 5224'South 391h Street, Phoenix, Arizona 85040
tel: (602) 438-2500 fax: (602) 438-2505 ROC#291316 www.smleng.com
IronRidge December 18, 2014
1495 Zephyr Ave Page 1 of 20
Hayward, CA 94544
Attn: Mr. David F. Taggart, Vice President Products
Subject: IronRidge XR10 Rail, Roof Flush Mounting System — Structural Analysis
Dear Sir:
We have analyzed the IronRidge XR10 Rail for the subject solar module support system and
determined that, for the configurations and criteria described below, it is in compliance with the
applicable sections of the following Reference Documents:
Codes: ASCE/SEI 7-10 Min. Design Loads for Buildings & Other Structures
California Building Code 2012 Edition
Other: AC428, Acceptance Criteria for Modular Framing Systems Used to Support PV
Modules, dated Effective November 1, 2012 by ICC-ES
Aluminum Design Manual, 2010 Edition
The IronRidge XR10 Rail is an extruded aluminum section with an overall depth of 1.75 in. and a net
area of 0.363 sq.in. The rails are used to support solar modules, typically, on the roof of a building.
See Exhibit A — attached. The rails are clamped to aluminum angle brackets that are either attached
directly to the roof framing or attached to a stand that is screwed to the roof framing. The rails are
mounted across the slope with a small clearance (flush mounting) to the underlying roof structure. The
installed solar modules are at the same slope as the underlying roof structure.
All loads are transferred to the roof framing through the angle brackets by simple bi-axial flexure of
the rails. The maximum span of the rails is governed by either the mid -span flexural stresses or the
deflection requirement that the rail not come into contact with the roof.
The effect of seismic loads (for all design categories A-F) have been determined to be less than the
effect due to wind loads in all load conditions and combinations. Therefore, the maximum allowable
spans for common load cases are shown in the tables below. Tables IA-9A are for modules with a
maximum long dimension of 67.5 inches and Tables 1 B-9B are for modules with a maximum long
dimension of 78.5 inches.
Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers
IronRidge December 18, 2014
Mr. David F. Taggart Page 5 of 20
IronRidge XR10 Rail, Roof Flush Mounting System Structural Analysis
Table 4A - MAXIMUM SPANS (in) - Roof Slope 70 to 270 - Wind Zone 1(67.5" Max Module Length)
XR10
Rail
Wind
Speed
Ground Snow Load
Exposure
mph
0 psf
10
psf
20
psf
30
psf
40
psf
50
psf
60
psf
70
psf
80
psf
90
psf
100
75
65
55
49
43
39
35
33
31
29
105
75
65
55
49
43
39
35
33
31
29
110
75
65
55
49
43
39
35
33
31
29
120
75
65
55
49
43
39
35
33
31
29
Category ory
130
75
65
55
49
43
39
35
33
31
29
140
71
65
55
49
43
39
35
33
31
29
150
66
65
55
49
43
39
35
33
31
29
160
62
62
54
48
43
39
35
33
31
29
170
59 1
59
53
47
1 43
39
35
33
31
1 29
100
75
65
55
49
43
39
35
33
31
29
105
75
65
55
49
43
39
35
33
31
29
110
75
65
55
49
43
39
35
33
31
29
120
70
65
55
49
43
39
35
33
31
29
Category
130
65
64
54
48
43
39
35
33
31
29
C
140
60
60
53
48
43
39
35
33
31
29
150
56
56
52
47
43
39
35
33
31
29
160
53
1 53
51
46
42
39
35
33
31
1 29
170
50
50
50
45
1 41
38
35
33
31
29
100
75
65
55
49
43
39
35
33
31
29
105
73
65
55
49
43
39
35
33
31
29
110
70
65
1 55
49
43
39
35
33
31
29
120
64
64
54
48
43
39
35
33
31
29
CateDgory
130
60
60
53
47
43
39
35
33
31
29
140
55
55
52
46
42
39
35
33
31
29
150
52
52
50
46
42
39
35
33
31
29
160
49
49
49
45
41
38
35
33
31
29
170
46
1 46
46
44
1 40
37
35
33
1 31
29
Notes - see page 20
f��wF^hy:i
CLEAN
SOLAR INC.
1445 KOLL CIRCLE.,
SUITE 109
San Jose, CA. 95112
Cont. Lic # 910849
www.cleansolar.com
LF�P1►1`�lS6LAR
F—
CC
W
O
o- =
-o
N
N L' Q co
o ��Lo
_v
w a
W Q co �-- Go
-�
W
G. w CMO- v
C0
� O
Z
C UII
aD
RTiBUilej�a(tillefl�
NAR 1112 2016
REVIEWED FOR
Reviewed By
Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers
-5-
RACKING ENGINEERING 1
bE COMPLIANC
DRAWN BY: JPH
REV:
SHEET NUMBER:
Z-004.2
Iron.Ridge December, 1:8_ 201.4
1GIr.'DavidV,, Taggart Page.20,6f,2.0.
IronRidge XRl`0. Rai1,;Roof;Flush'Mounting; System—:S:tructural Analysis
Notes; —Tabulated: values are based.onthe following; criteria;
Buildingmean roof heigbt= 30.ft
2., Risk Category I
3`. _
Solar maximum.miod'ulej long_duriens on is.67.5 inches for. Tables :1A=.9A'and 78:5:inches for
Tables IB 9B.
4i Provide 2 M clear between roof and rail
5. End cantilever span (max) = 0 4..0 x maximum man from above 'tables
6: No rail: splices yin .end spans.
7. Nor splices':in middle .1/3 of'inietior spans
8. $inglesimple spans}: Spansaiste-d.m. tlie'tables above may be multiplied by 1.08 for
continuous rails of 3" or more- spans,
Our analys><s' assumes that the ;rail`s, including : e connections and. associated hardware,. are installed;
in a workmanlike manner .in atcordane6 with the " IroriRidge..Roof Mount TnstalIation:MAnual" by
'IronRidge: and .generall: accepted standards. oficonstruction:practice AdditioriaI information is
- favailable atthe RonRid a web, site IronRid ecom VionoPaModule: ca a.cttY to support,.
t.
ated with- the: bethe,responliy:ftieotacor. andtheloadsassocivItCOwner noflronRidgo�orlStarling Madison Lofquist.:
The ,ad .quacy-of the supporting roof framing -,is to be determined by.others.
Please -feel .free to, coritactme at, -your :convenience if you have any .questions.:
Respectfully- yours,..
Tres Warner,
Design Division Manager
a
W
All 1
C71973
EXR
sr CtVfu ..
��Q''CA�
staling Mad son.Lofqu st; Inc: .Consulting Structura1and.F-4ensic Engineers
20
RACKING ENGINEERING 2
25800 Commercentre Drive
Lake Forest, CA 92630 USA
Telephone: 949.448.4100
Facsimile: 949.448.4111
www.intertek.com
Test Verification of Conformity
In the basis of the tests undertaken, the sample(s) of the below product have been found to comply with the requirements of
the referenced specifications at the timerthe tests were carried out.
Applicant Name & Address:
Product Description:
Ratings & Principle
Characteristics:
,Models:
Brand Name:
Relevant Standards:
Verification .issuing Office;
Date of Tests:
Test;Report'Number(s):
This verification is part rbf tl
imply product certification.
IronRidge, Inc. --
1495 Zephyr Ave.
Hayward CA 94544
XR.Rails with -Integrated Grounding.
Fire Class Etesistance Rating:
Class A.for Steep Slope Flush -Mount (symmetrical) Applications when using 6rype."1 and
Type1, Listed Photovoltaic Module. .
Class A'for Low'slo a Flush,Mount and Tilt -Mount (symmetrical and asymmetrical)
Applications when using Type 1,. Listed Photovoltaic module,.
51-61GD-005,,,51-61GD-005B,51-5000-001, and 51-65-001
N/A
UL Subject 2703(Section '15.2 and 15.3) Outline of Investigation for Rack Mounting'Systems and
Clamping Devices,for Flat-Plate�Photovoltaic Modules and Panels,, Issue Number:,2, Nov;13,2012
Referencing UL1703 (Section'31.2) Standard for Safety for Flat -Plate Photovoltaic Modules and
Panels, May 20, 2014,
Intertek Testing Services- NA,. Inc.
25800 Commercentre.Dr.
Lake Forest, CA 92630
08/27/2014 to'01/07/2015
101541132LAX-002 ,
Completed by: AmarKacel
Title: P.0 Engineer
Signature: y
( Dater 01/26/2015
reports)
:be read in.conjunction with them:
Reviewed bye Andrew Koretoff
Title: Reviewer
'Signature: a �j{--
Date: 01/-26/2015
report does
rw,5
C U 1
e
All
R C(
Reviewed By:
This Verification is for the exclusive use of intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are
limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement for any loss, expense
or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its
marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results
referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product or service is or has ever been
under an Intertek certification program.
GFT-OP-11a (24-MAR-2014)
RACKING FIRE RATING
CLEAN
SOLAR INC.
1445 KOLL CIRCLE.,
SUITE 109
San Jose, CA. 95112
Cont. Lic # 910849
www.cleansolar.com
CLEAI'VSOLAR
W
m
a
= -mr
�
���
N
o
W
V CP
�
N
Z azr`
W
LL3
O
d
WCEO
N d v
Cn
V
0 V
Z
COO
_
INO
artment
III •PLIANCE
DRAWN BY: JPH
DATE: 2/24/16
REV: 2/26/16
SHEET NUMBER:
Z-004.3
A►. IRON RIDGE Integrated Grounding System I Installation Overview
Simplified Grounding
For Greater Safety & Lower Cost
Traditionally, solar modules are grounded by attaching
lugs, bolts or clips to the module frame, then connecting
these to a copper conductor that runs throughout the
array. This process adds time and cost to the installation,
and often results in improper grounding, creating
significant long-term safety risks.
The IronRidge Integrated Grounding System solves these
challenges by bonding modules directly to the mounting
rails. This approach eliminates separate module
grounding hardware, and it creates many parallel
grounding paths throughout the array_, providing
greater safety for system owners.
2. � -1 - - .
�'
Grounding Strap
Grounding Straps are used to
bond. rail -to -rail connections.
They are only required on the
rail with the grounding lug.
Install Roof Attachments CLEAN
• Install appropriate roof flashing and/or standoff for roof type. SOLAR INC.
AM7 1 1445 KOLL CIRCLE.,
• Attach L-Feet to flashing or standoff. SUITE 109
i
_ _ San Jose, CA. 95112
Grounding Mid Clamp
Each Grounding Mid Clamp pierces through the
anodized coatings of both thamodule-frame and
the, -mounting rail to form:secure electricaLbonds,
which are'repeated throughout the array.
3
% ,W Grounding Lug
A single Grounding Lug
connects an entire row'
of PV modules toathe,
grounding conductor.
io Prepare Rail Connections L&1-)R,I I Cont. Lic # 910849
• Insert splice into first rail, then secure with Grounding Strap and
self -drilling screw.
• Slide second rail over splice, then secure with opposite end of
Grounding Strap and self -drilling screw.
Mount & Ground Rails
• Attach rails to L-Feet and level rails.
• Install one Grounding Lug per row of modules.
• Connect Grounding Lug to grounding conductor.
53 Install Modules & Clamps
• Install first module using End Clamps and Grounding Mid Clamps.
• Install additional modules using Grounding Mid Clamps.
• Finish row with a second pair of End Clamps.
Testing & Certification
The IronRidge Integrated Grounding
System has been tested and certified to
UL 2703 by Intertek Group plc.
UL 2703 is a proposed UL standard
for evaluating solar module mounting
and clamping devices. It ensures these
devices will maintain strong electrical and
mechanical connections over an extended
period of time in extreme outdoor
environments.
The testing process closely mirrors that
of UL 1703, the solar module testing
standard, including temperature and
humidity cycling, electrical and mechanical
load testing, and manufacturing quality
reviews.
6
l a] Module Frame Compatibility
A
Any module frames whose parameters are not listed In the
provided table have not been tested for compatibility. Ll-
E; y
U C
The Grounding Clamp has proven robust in ground66-6eilland
72-cell solar module frames with box construction >,;da, rang$ of ;
anodization thicknesses.
All solar modules listed to UL 1703 and with frame [RCHQ'gr[O4 --tD FO
within the parameters stated above are compatible with the
IronRidge Integrated Grounding System. Reviewe
:J Go to ironrdge,corn/ig
Dimension
Range
A
31.Omm - 51.Omm
B
5.08mm (minimum)
j P F
ling
RC
By:
GROUNDING 5 BONDING SPECIFICATIONS
www.cleansolar.com
OW,
IVQ`1!
10~C
W
m
C-
.Cr
M
�y=�
W
W C� CM7
N
�'CO
Q N
Cz
�
azr`
0
' l�
CL.
w
N CL
��
Cn
®
C.2
Z
Q
TI Nr
partment
2016
10 COMPLIANCE
DRAWN BY: JPH
DATE: 2/24/16
REV: 2/26/16
SHEET NUMBER:
Z-005
SIMME I CARBON A40NOXIDE ALARMS
OWNER CE"'IFICATEE, OF COMPLIANGE,
COMMUNITY05-VtLOPT1ENT DEPARTMENT- BULDING DIVISION
10300 TORRE AVIiNUE,a CCUPERTWO, to 4-325'-5
(4,08) -32284!rAXj408)7-777,33S, buildiijoe—m-polkip-om 7TI-"
� Address
Pj�J30S,
Tbis afWa is a selfcerfification for the in8tallation of all xequi-Te-d Smokean4i Carbon Moroxide AIM MS fQj-
couipffimice vviffi:2013 CRC Section R314,, 2013, C-B C , -Sections 420.6 and 90 7.2.112 wher'e DO illtehdt aUeSS f0T
inspctiom are re-quiro-d-
GE,�ERAiiNFmmkwrioN
Fbisfai,g single-f arnfly, and multi-f-amily- dvvellm'gs 4-iall be provided with, Smoke A.Imms and. Carbon
dureffingunits exceeds
$1000-00, CRC Section R314.wncl CBCSections,90.2.11.5 and 4W.6 and/or Cftfbon
'Monoxide Alw-xnabe stalled in the following locations:
AREA
W OKE ALAOT. CO ALARM
Outside 011'each separat� ' Iftping aTea in the inun-edlate- vidnity of the
X X
1 On f ikyery' le�vel o a dwelIN'unit in�luqL7% basenigAts
X
VV' 3' lift each 10 q g 190in
Cafbon Monoxide alarms are not te d dNvelli-np -M-d0i idc�-nqt cantain fvel�-burnyfttg a ' d"
quire, in pp amice4 at
don t have an attac
CBC Section 420.6 acid :shad be appmovedby file offic oftheStattiFirzMaxshal.
oweT supp ro-,,v,er',"3upply.Indwehing:un-i-i --wthno oannierdalp ly, "ar-tn(s)mkvlie-solelybatteryo'peratp-J-
not xesTult in the re.-no-val of vvaU and ceirmg-ftishes -or there is, no access means of attic, basement or crawl
space- Refer I-o CR' Secdoo R314 .and CT 15'ectfains 90721.1A and,420.6.2. An electrical pem-dt is required for
alam -v,; ivfdch must be comlected to the bufldfiv' A."rinla".
Asolvne.r*f the above-ieferenced prQpeTty, Ibereby ceirtify ffiat been
instalIed in aixordanoe with the, manufactuTer's instruclimi-s mid in com va. th rraa the:talffb I Building
and Calffonija Residential Cbdes-Th� apd,arebperztjql, asof the date signed
,I 178ve Me a e to cvipj 1111M fhaiarrj)&-and �6rfdilfOng of thft sloteMent
Contractor Niamv.
q
......... Date,
Swbh, 4nd CQf&-h%.,I00
WATER -CONSERVING PLUMBING FIXTURES
OWNER CERTIFICATE OP COMPLIANCE
Eig COMMUNrNDEVELOPMENT DEPARTMENT - BUILDING DIVISION
CUPERT11WO 10300 TORRE AVENUE - CUPERTINO, CA 95014-3255
tAWIF1777 8 A;3
OwnerName FAX (408) 777-3333 - buildingaCupertino .oEg
Permit No.
Address
1. Is your real property a registered historical site?
n O(Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. No Go to Question 2.
2. Does your real property have a licensed plumber certifying that due to the age or configuration of the property or its
plumbing, installation of water -conserving plumbing fixtures is not technically feasible?
0 Yes Civil Code Sections 1101.1 through 1101.8 do not apply.
0 The licensed plumber's certification has been provided to the Building Division.
Skip the rest of the forni and sign bottom of form.
No Co to Question 3.
3- Is water service permanently disconnected for your building?
0,JYes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form.
2"No Co to Question 4.
4. Is your real property built and available for use or occupancy on or before January 1, 19947
Cl No My real property inbuilt and available for use or occupancy after January 1, 1994.
Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form.
Yes My real property is built and available for use or occupancy on or before January 1, 1994.
Civil Code Sections 1101.1 through 1101.8 apply. Check one of theithree following statements and sign
bottom of form..
S. PlOase check ONE of the following:
MY Property is a single-family residential real property. See Civil Code Section 1101.4.
On and after January'l, 1014, building alterations or improvements, shall 4
require all non -compliant plumbing fixtures
to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non-
compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless of whether
property undergoes alterations or improvements).
0 My property is a multifamily rWdential real property. See Civil Code Section 1101.5.
On and after January 1, 2014, specified building
ilding alterations or improvements shall require non- compliant
plumbing fixtures to be replaced with water -conserving plumbing fixtures.
Ing
On or before January 1, 2019, all noncompliant plumbing fixtures shall be replaced with water -
conserving plumbing fixtures throughout the building (regardless of whether property -undergoes alterations or
improvements).
0 My property is a commercial real property See Civil Code Section 1101.5.
On, and after January 1, 2014, specified building alterations or improvemefttg shall require non- compliant
plumbing fixtures to be replaced with water -conserving plumbing fixtures.
On or before January 1, 2019, all non -compliant plumbing fixtures shall be replaced with water- conserving.
plumbing fixtures throughout the building (regardless ofwhether property undergoes.alterations or. improvements).
L as the owner or owner's agent of this property, certify under penalty of perjury that non -compliant plumbing fixtures will be
replaced prior to date specified above with water -conserving plumbing fixtures in accordance with Civil Code Sections 1101.1
through 1101.8, the current California Plumbing Code and California Grew Building Standards Code, and manufacturer's
installation requirements, and that the water -conserving I tubing fixtures comply with the requirements as indicated it the
9P u%1 Ing
table on the following uaae. .09 /_ ^, F -, # e
I r10
completing and signing this Certificate, P "as e7turn it to the Building.ivision in order to final your
SB40720151doc revised 0,W645