Loading...
15080067CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 10257 GLENCOE DR CONTRACTOR: TRACY HSU PERMIT NO: 15080067 OWNER'S NAME: TRACY HSU 22333 SANTA PAULA AVE DATE ISSUED: 10/01/2015 OWNER'S PHONE: 4084645030 CUPERTINO, CA 95014-2835 PHONE NO: ❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL ❑ COMMERCIAL CONSTRUCT (N) 2 STORY SFD (3727 S.F.) COVERED License Class Lic. # PORCH (616 S.F.) WITH ATTACHED GARAGE (489 S.F.) Contractor Date I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: Sq. Ft Floor Area: Valuation: $700000 t. I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the APN Number: 32630016.00 Occupancy Type: performance of the work for which this permit is issued. 2. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. PERMIT EXPIRES IF WORK IS NOT STARTED APPLICANT CERTIFICATION WITHIN 180 DAYS OF PERMIT ISSUANCE OR I certify that I have read this application and state that the above information is 180 DAYS FROM LAST CALLED INSPECTION. correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned for inspection property purposes. (We) agree to save Issued by: Date: indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. RE -ROOFS . All roofs shall be inspected prior to any roofing material being installed. If a roof is Signature Date installed without first obtaining an inspection, I agree to remove all new materials for inspection. Signature of Applicant: Date: OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER the following two reasons: t. I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for HAZARDOUS MATERIALS DISCLOSURE sale (Sec.7044, Business & Professions Code) I have read the hazardous materials requirements under Chapter 6.95 of the I, as owner of the property, am exclusively contracting with licensed contractors to California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain construct the project (Sec.7044, Business & Professions Code). compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a) should I store or handle hazardous material. I hereby affirm under penalty of perjury one of the following three declarations: Additionally, should I use equipment or devices which emit hazardous air t. I have and will maintain a Certificate of Consent to self -insure for Worker's contaminants as defined by the Bay Area Air Quality Management District I will Compensation, as provided for by Section 3700 of the Labor Code, for the maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the performance of the work for which this permit is issued. 2. I have and will maintain Worker's Compensation Insurance, as provided for by Health & Safety Code, Sections 25505, 25533, and 25534. Owner or autl 'i'zed a4 Section 3700 of the Labor Code, for the performance of the work for which this Date: permit is issued.a s. 1 certify that in the performance of the work for which this permit is issued, I shall /CONSTRUCTION LENDING AGENCY not employ any person in any manner so as to become subject to the Worker's I hereby affirm that there is a construction lending agency for the performance of work's Compensation laws of California. If, after making this certificate of exemption, I for which this permit is issued (Sec. 3097, Civ C.) become subject to the Worker's Compensation provisions of the Labor Code, I Lender's Name must forthwith comply with such provisions or this permit shall be deemed revoked. Lender's Address APPLICANT CERTIFICATION ARCHITECT'S DECLARATION I certify that I have read this application and state that the above information is I understand my plans shall be used as public records. correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter Licensed Professional upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the upeitino Municipal Code,Section9.18. Signature Date{ CITY OF CUPERTINO 1503W6,R_ - FF,F, FqTl[-N4 A Tn1D — RITTY 7MTVI_' "1X71rQTd'%XT 1AADDRESS: 10267 GLENCOE DR. TYPE OF CONSTR. DATE: 08/07/2015 REVIEWED BY: PAUL APN: 326 30 016 BP FEES BP FEE ID *VALUATION: 1$700,000 j 11-B,111-B,1V,V-B 4,832 $3,342.57 JR3PLNCK *PERMIT TYPE: Building Permit PLAN CHECK TYPE: New Construction FRMARY SFD Duplex 2nd Unit? 0 Yes E) No PENTAMATION USE: or I PME Plan Check: PERMIT TYPE: 1 R3SFDW WORK Construct (N) 2 story SFD (3727 S.F. Covered Porch (616 S.F. with Attached Garage (489 S.F. SCOPE OCCUPANCY TYPE: TYPE OF CONSTR. FLR AREA (s.f.) PC FEES PC FEE ID BP FEES BP FEE ID R-3 (Custom) 11-B,111-B,1V,V-B 4,832 $3,342.57 JR3PLNCK $4,037.37 IR3INSP $0.00 PME Plan Check: $0.00 Permit Fee: $4,037.37 Suppl. Insp. Feer Reg. 0 OT F—O0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: TOTALS: 4,832 $3,342.57 -7 $4,037.37 —$0.00 1 I Plan 0qeck tech. Per Fee: Phonb. Man C'heck 1111(mb, Per n,,;r Fe(c: E'/eo, Man Check 1.7(.,C. Ilernlit Fee: Other UeJi, Jnsj.>, Other 11howbbi-s-p. Oilier Ele", In -11,10. Hoch. hn"). Fee: Mnmb. Imp. Fee: Elec. Insp. Foe: NOTE.* This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanh District, School District. etc.). f7,­f­fih,Dont fir Al"91i.Aq FEE ITEMS (Fee Resolution .1.7-053 Eff. 711113) FEE QTY/FEE MISC ITEMS Plan Check Fee: $3,342.57 Select a Misc Bldg/Structure or Element of a Building Su 1. PC Fee: •Q) Reg. 0 OT I _00 hrs $0.00 PME Plan Check: $0.00 Permit Fee: $4,037.37 Suppl. Insp. Feer Reg. 0 OT F—O0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: Construction Tax: IBCONSTAXRF —$0.00 1 # new 1 units $684.98 _4thnini_slraflve Fee: 0 (9 Work Without Permit? Cl Yes (E) No $0.00 Advanced. Planning Fee. IPLLONGR $676.481 Select a Non -Residential Building or Structure E) 0 Strong Motion Fee: IBSEISMICR $91.00 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC j $28.00 $8,860.40 $0.00 TOTAL F, 1 $8,860.400 Revised: 07/02/2015 CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 I (408) 777-3228 • FAX (408) 777-3333 • building d)cupertino.org �t,�Ir� RT'No (=! NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION / TI ❑ REVISION / DEFERRED ORIGINAL PERMIT # PROJECT ADDRESS i �b APN # "p L SI2 � OWNER NAME gg j _ ry �-� PHONE �i .m '°'� � E-MAIL /_ �i' •'K. P< ,mss 3 i �gdi�`i� n STREET ADDRESS 4CITY, STATE, ZIP e,4 01 FAX CONTACT NAME • s PHONE to � .. E-MAIL ��� k, S BEET ADDRESS CITY, STATE, ZIP FAXg ❑ OWNER ❑ OWNER-BUII,DER ❑ OWNER AGENT ❑ CONTRACTOR ❑ CONTRACTOR AGENT CHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME LICENSE NUMBER LICENSE TYPE BUS. LIC # COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE CHITECT GINIEER NAME LICENSE NUMBER i� enA BUS. LIC # COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE DESCRIPTION OF WORK OLL 9 EXISTING US �q PROPOS USE - CONSTR. TYPE , g i� # STORIES USE TYPE OCC. SQ.FT. VALUATION ($) EXISTG AREA ' NEW FLOOR AREA ';1-� DEMO AREA [ 0 06 TOTAL ,✓{ NET AREA ' "�( q tl li s 8 BATHROOM REMODELAREA k KITCHEN REMODELAREA 1 f�a. OTHER REMODEL AREA i )/A �,P_ 0 C> L; PORCH AREA. DECK AREA TOTAL DECK TORCH AREA GARAGE AREA: DETACH J r3❑YES #DWELLINGUNITS: IS A SECOND UNIT SECONDSTORf El YES BEING ADDED? UPO ADDITION? hl -1 N.9 PRE -APPLICATION t219ES IF YES, PROVIDE COPY OF IS THE BLDG AN ❑ YESEDB,, _ TOTAL VALUATION: PLANNINGAPPL# NO PLANNING AP TF EICHLERHOME? NO �` - to By my signature below, I certify to each of the following: I am the property owner authorized agent to act on the property OWner's behalf. I have -this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to buildin construction. I authorize representatives of Cupertino to enter the above -identified property for inspection purposes. Signature of Applicant/Agent: Date: �! (S.- SUPPLEMENTAL INFORMATION REQUIREDnP _PLANCH�CKTYPE ,r, al e. ,RbIiTINGSLIP s New SFD or Multifamily dwellings: Apply for demolition permit for OVEit TIEkCflQNTER `QgUu DING pLAN REVII ws _ existing building(s). Demolition permit is required prior to issuance of building s k ` permit for new building. CI TXP SRE � ��PLANREiiEW Bldgs: Provide a completed Hazardous Materials Disclosure - ST�INDARD PIJBLIU wgzxs _Commercial Form if any Hazardous Materials are being used as part of this project. f�AitcE << PIREDEPT u Copy of Planning Approval Letter or Meeting with Planning prior to ' z ` Iv7AJOR [] SAiVTfARybEWER�IviTRICT _ submittal of Building Permit application. X � � �� _ �,�., �,❑. �NVIRONIITENTALHEALTH BldgApp 2011. doe revised 06/21/11 Building Department City Of Cupertino ✓ ELI] 10300 Torre Avenue Cupertino, CA 95014-3255 Telephone: 40&777-3228 C U P E RT I N O Fax: 408-777-3333 CONTRACTOR / SUBCONTRACTOR LIST *Our municipal code requires all businesses working in the city to have a City of Cupertino business license. NO BUILDING FINAL OR FINAL OCCUPANCY INSPECTION(S) WILL BE SCHEDULED UNTIL THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS HAVE OBTAINED A CITY OF CUPERTINO BUSINESS LICENSE. I am not using any subcontractors: Signature Please check applicable subcontractors and complete the following information: Date ✓ SUBCONTRACTOR BUSINESS NAME BUSINESS LICENSE # • � • �/. �.a pili � ��. ate.' draehs � ...•:. uW. 3 4-119 Z -Cl- *Our municipal code requires all businesses working in the city to have a City of Cupertino business license. NO BUILDING FINAL OR FINAL OCCUPANCY INSPECTION(S) WILL BE SCHEDULED UNTIL THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS HAVE OBTAINED A CITY OF CUPERTINO BUSINESS LICENSE. I am not using any subcontractors: Signature Please check applicable subcontractors and complete the following information: Date ✓ SUBCONTRACTOR BUSINESS NAME BUSINESS LICENSE # Cabinets & Millwork t 3 4-119 Z -Cl- Cement Finishing N 1 4-Z+ 0 / Electrical{- � Excavation AM1 - Fencing Flooring / Carpeting y Linoleum / Wood !�- ( ass / Glazing Heating Le H ea -1-i t*otA b c, 16 y' Insulation Landscaping M 12j C 4 a Z i Lathing Masonry (- Painting / Wallpaper- A41 1A `�C Paving - c 9 RZ Plastering ' -- e 7j 7j i Plumbing '-G - /- Roofing A 52 CJD g 6 a Septic Tank ZPX r Sheet Metal Sheet Rock S 2 Tile MX-� 71' er %Contractor Signature Date OWNER -BUILDER DISCLOSURE FORM COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building aa)cupertino.org Dear Property Owner(s): An application for a building permit has been submitted in your name listing yourself as the builder of the property improvements specified at: SITE ADDRESS, APN 3 Q BP# �L--^ OWNER NAME OWNER ADDR SS add -01- DESCRIPTION - /F WORK: - . . . I 1-- j We are providing you with an Owner -Builder Acknowledgment and Information Verification Form to make you aware of your responsibilities and possible risk you may incur by having this permit issued in your name as the Owner -Builder. We will not issue a building permit until you have read, initialed your understanding of each provision, signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice unless you, the property owner, obtain the prior approval of the permitting authority. OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION (DIRECTIONS: Please read and initial each statement below to signify you understand or verify this information.) -lem 1. 1 understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner- Et—der" building permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as an Owner -Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my insurance coverage for injuries to workers on my property. —re2. I understand building permits are not required to be signed by property owners unless they are responsible for the construction and are not hiring a licensed Contractor to assume this responsibility. 1te 3. 1 understand as an "Owner -Builder" I am the responsible party of record on the permit. I understand that I may ct myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead of my own. *rt4. I understand Contractors are required by law to be licensed and bonded in California and to list their license numbers on permits and contracts. 5. 1 understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the t tal value of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employer" under state and federal law. 6. 1 understand if I am considered an "employer" under state and federal law, I must register with the state and f eral government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment compensation for each "employee." I also understand my failure to abide by these laws may subject me to serious financial risk. 1r7. 1 understand under California Contractors' State License Law, an Owner -Builder who builds single-family idential structures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed under contract with a licensed general building Contractor. 8. 1 understand as an Owner -Builder if I sell the property for which this permit is issued, I may be held liable for any financial or personal injuries sustained by any subsequent owner(s) that result from any latent construction defects in the workmanship or materials. OwnerBuilderForm 2010.doc revised 04/14/10 1 understand I may obtain more information regarding my obligations as an "employer" from the Internal 4'. nue Service, the United States Small Business Administration, the California Department of Benefit Payments, and the California Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1-800-321-CSLB (2752) or www.cslb.ca.gov for more information about licensed contractors. 7 10. 1 am aware of and consent to an Owner -Builder building permit applied for in my name, and understand that I a the party legally and financially responsible for proposed construction activity at the site address listed above. 11. 1 agree that, as the party legally and financially responsible for this proposed construction activity, I will abide b all applicable laws and requirements that govern Owner -Builders as well as employers. 12. 1 agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the nformation l have provided on this form. Licensed contractors are regulated by. laws designed to protect the public. If you contract with someone who does not have a license, the Contractors' State License Board may be unable to assist you with any financial loss you may sustain as a result of a complaint... Your only remedy against unlicensed Contractors may be in civil court. It is also important for you -to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working on your property, you may be held liable for damages. If you obtain a permit as Owner -Builder and wish to hire Contractors, you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers' compensation insurance coverage. CONSTRUCTION LENDING AGENCY (DIRECTIONS: Please complete the following construction lending agency information.) I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097 Civ.) Lender Name: Lender Address: Before a building permit can be issued, this form must be completed and signed by the property owner and returned to the agency responsible for issuing the permit. Note: A copy of the property owner's driver's license, form notarization, or other verification acceptable to the city may be required to be presented when the permit is issued to verify the property owner's signature. Property Owner's Signature: _ Date: �a --- - -- - -- -------------------------------------------------------------------------------------------------- (NOTE: The following Authorization Form is required to be completed by the property owner only when designating an agent of the property owner to apply for a construction permit for the Owner -Builder). AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize the following person(s) to act as my agent(s) to apply for, sign, and file the documents necessary to obtain an Owner -Builder Permit for my project. Scope of Construction Project (or Description of Work): Project Location or Address: Name of Authorized Agent: Address of Authorized Agent: Tel No I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above information and certify its accuracy. Note: A copy of the property owner's driver's license, form notarization, or other verification acceptable to the city may be required to be presented when the permit is issued to verify the property owners signature. Property Owner's Signature: Date: OwnerBuilderForm 2010.doc revised 04/14/10 I BUILDING ENERGY ANALYSIS REPORT 1 PROJECT: SINGLE HOUSE 10381 BRET AVE. CUPERTINO, CA 95014 Project Designer' C �epG�nf SEP 2 5 2015 REVIEVVED SUR C;C?)E C%UMPI_IANCE RevieWea gy Report Prepared by: PERFECT DESIGN & DEVELOPMENT, INC. opy SUBMITTA Job Number: R15-3933 BY Date: 8/3/2015 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 6.6 by Ener ySoft User Number 1919 /D. R15-3933 F TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF -1 R -PRF -01-E Certificate of Compliance 3 Form RMS -1 Residential Measures Summary 12 Form MF -1R Mandatory Measures Summary 13 HVAC System Heating and Cooling Loads Summary 17 Room Load Summary 19 Room Heating Peak Loads 21 Room Cooling Peak Loads 23 6.6 ID: R15-3933 User Number: 1919 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: SINGLE HOUSE Calculation Date/Time: 16:05, Mon, Aug 03, 2015 Calculation Description: Title 24 Analysis Input File Name: R15-3933.xmi CF1 R -PRF -01 Page 1 of 9 COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below 04 05 ENERGY USE SUMMARY 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 14.96 11.17 3.79 25.3% Space Cooling IAQ Ventilation 8.84 0.93 12.24 0.93 -3.40 0.00 -38.5% 0.0% Water Heating 8.14 6.97 1.17 14.4% Photovoltaic Offset ---- 0.00 0.00 Compliance Energy Total 32.87 31.31 1.56 4.7% Registration Number: 215-N0214527A-000000000-0000 Registration Date/Time: 2015-08-0316:11:24 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 HERS Provider: CaICERTS inc. Report Generated at: 2015-08-03 16:06:42 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: SINGLE HOUSE Calculation Date/Time: 16:05, Mon, Aug 03, 2015 Page 2 of 9 Calculation Description: Title 24 Analysis Input File Name: R15-3933.xmi REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Ducts with high level of insulation • Cathedral Ceiling • Ceiling has high level of insulation HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing • Duct Design -Return • Duct Design -Supply Domestic Hot Water System Verifications: • -- None -- ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. Reference Energy Use I Energy Design Rating Total Energy (kTDV/f2 yr)* 73.62 72.06 * includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 1 02 03 Number of Dwelling Conditioned Floor Area (ft2) Units 3727 1 Project Name SINGLE HOUSE 04 Number of Bedrooms 4 05 Number of Zones 2 Margin I Percent Improvement 1.56 2.1% Registration Number: 215-N0214527A-000000000-0000 Registration Date/Time: 2015-08-03 16:11:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-03 16:06:42 06 07 Number of Ventilation Cooling Systems Number of Water Heating Systems 0 1 Registration Number: 215-N0214527A-000000000-0000 Registration Date/Time: 2015-08-03 16:11:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-03 16:06:42 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: SINGLE HOUSE Calculation Date/Time: 16:05, Mon, Aug 03, 2015 Calculation Description: Title 24 Analysis Input File Name: R15-3933.xml ZONE INFORMATION 01 02 03 04 Zone Name Zone Type HVAC System Name Zone Floor Area (ft) 1ST FLOOR PLAN Conditioned 1ST FLOOR AREA1 2434 2ND FLOOR PLAN Conditioned 2ND FLOOR AREA2 1293 CFI R -PRF -01 Page 3 of 9 OPAQUE SURFACES 05 06 07 Avg. Ceiling Height Water Heating System 1 Water Heating System 2 9 DHW Sys 1 02 Zone 1ST FLOOR PLAN 1ST FLOOR PLAN 1ST FLOOR PLAN 1ST FLOOR PLAN 1ST FLOOR PLAN 1ST FLOOR PLAN 2ND FLOOR PLAN 2ND FLOOR PLAN 2ND FLOOR PLAN 2ND FLOOR PLAN 2ND FLOOR PLAN 9 DHW Sys 1 05 Orientation Back Front547.6 Right Left Back Front Right Left OPAQUE SURFACES 05 08 06 Orientatio n Area (ft) Skylight Area (ft2) Roof Rise (x in 12) 01 Name WEST WALL EAST WALL NORTH WALL SOUTH WALL R-38 Roof 3 Raised Floor WEST WALL 2 EAST WALL 2 NORTH WALL 2 SOUTH WALL 2 R-38 Roof 4 02 Zone 1ST FLOOR PLAN 1ST FLOOR PLAN 1ST FLOOR PLAN 1ST FLOOR PLAN 1ST FLOOR PLAN 1ST FLOOR PLAN 2ND FLOOR PLAN 2ND FLOOR PLAN 2ND FLOOR PLAN 2ND FLOOR PLAN 2ND FLOOR PLAN 03 Construction R-21 Wall R-21 Wall R-21 Wall R-21 Wall R-38 Roof Attic R-19 Floor W/ Crawlspace R-21 Wall R-21 Wall R-21 Wall R-21 Wall R-38 Roof Attic 04 Azimuth 270 90 0 180 270 90 0 180 05 Orientation Back Front547.6 Right Left Back Front Right Left 06 Gross Area (ft2) 529.3 573.5 606.8 1324 2434 342 342 352 352 1275 07 Window & Door Area (ft) 225 141.4 91.5 95 62.1 49.6 21.2 35.4 08 Tilt (deg) 90 90 90 90 yo 90 90 90 OPAQUE SURFACES — Cathedral Ceilings 01 02 03 Name Zone Type R-38 Roof 1ST FLOOR PLAN R-38 Roof Atticl R-38 Roof 2 2ND FLOOR PLAN R-38 Roof Atticl 04 05 08 06 Orientatio n Area (ft) Skylight Area (ft2) Roof Rise (x in 12) Right 18.1 18 4 Right 18.1 18 4 Registration Number: 215-N0214527A-000000000-0000 Registration Date/Time: 2015-08-0316:11:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-03 16:06:42 07 08 09 10 11 Roof Pitch Roof Tilt (deg) Roof Reflectance Roof Emittance Framing Factor 0.33 18.43 0.1 0.85 0.07 0.33 1 18.43 0.1 0.85 0.07 Registration Number: 215-N0214527A-000000000-0000 Registration Date/Time: 2015-08-0316:11:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-03 16:06:42 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF7 R -PRF -01 Project Name: SINGLE HOUSE Calculation Date/Time: 16:05, Mon, Aug 03, 2015 Page 4 of 9 Calculation Description: Title 24 Analysis 9 Input File Name: R15-3933.xm1 ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic 1ST FLOOR PLAN Attic Roof1ST FLOOR PLAN Ventilated q 0.1 0.85 No No Attic 2ND FLOOR PLAN Attic Roof2ND FLOOR PLAN Ventilated q 0.1 0.85 No No Registration Number: 215-N0214527A-000000000-0000 Registration Date/Time: 2015-08-03 16:11:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-03 16:06:42 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: SINGLE HOUSE Calculation Date/Time: 16:05, Mon, Aug 03, 2015 Calculation Description: Title 24 Analysis Input File Name: R15-3933.xml OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Construction Name Surface Type Construction T Total Cavity Winter Design Ype Framing R -value U -value Assembly Layers • Cavity/ Frame: no insul. / 2x4 Top Chrd Attic Roof1 ST FLOOR PLAN Attic Roofs Wood Framed Ceilin 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking 9 in. O.C.Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity / Frame: R-9.1 / 2x4 • Over Floor Joists: R -2B.9 insul. • Inside Finish: Gypsum Board Cavity / Frame: R-38 / 2x4 • Roof Deck: Wood Siding/sheathing/decking • Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity / Frame: R-21 / 2x6 • Exterior Finish: Wood Siding/sheathing/decking • Floor Surface: Carpeted • Floor Deck: Wood Siding/sheathing/decking • Cavity / Frame: R-19 / 2x6 • Cavity/ Frame: no insul. / 2x4 Top Chrd • Roof Deck: Wood Siding/sheathing/decking • Roofing: Light Roof (Asphalt Shingle) • Floor Surface: Carpeted • Floor Deck: Wood Siding/sheathing/decking • Cavity / Frame: R-19 / 2x6 • Ceiling Below Finish: Gypsum Board CF1 R -PRF -01 Page 5 of 9 Ceilings (below R-38 Roof Attic attic) FWFramed Ceiling R-38 Roof Attic1 R-21 Wall R-19 Floor W/ Crawlspace Attic Roof2ND FLOOR PLAN Cathedral Ceilings I Wood Framed Ceiling none 0.644 2x4 @ 24 in. O.C. R 38 2x4 @ 24 in. O.C. R 38 Exterior Wails Wood Framed Wall 2x6 @ 16 in. O.C. Floors Over Crawlspace Wood Framed Floor 2x6 @ 16 in. O.C. 2x4 Top Chord of Roof Truss @ 24 Attic Roofs Wood Framed Ceiling in. O.C. R-19 Floor W/O Crawlspace I Interior Floors I Wood Framed Floor I 2x6 @ 16 in. O.C. BUILDING ENVELOPE - HERS VERIFICATION 01 Quality Insulation Installation (011) Not Required WATER HEATING SYSTEMS 01 Name DHW Sys 1 - 1/1 02 Quality Installation of Spray Foam Insulation Not Required R21 R 19, R19 0.025 0.036 0.066 0.049 0.644 0.048 03 Building Envelope Air Leakage Not Required 02 03 04 System Type Distribution Type Water Heater DHW Standard DHW Heater 1 05 Number of Heaters 1 04 ACH @ 50 Pa 06 Solar Fraction (%) .0% Registration Number: 215-No214527A-000000000-0000 Registration Date/Time: 2015-08-03 16:11:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-03 16:06:42 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: SINGLE HOUSE CF1R-PRF-01 Calculation Date/Time: 16:05, Mon, Aug 03, 2015 Page 6 of 9 Calculation Description: Title 24 Analysis Input File Name: R15-3933.xml WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type fTankVolume Energy Factor or Tank Type al) Tank Exterior Insulation Standby Loss DHW Heater 1 Natural Gas Efficiency Input Rating R•value (Fraction) Small Storage 75 0.69 72000-Btu/hr 0 0.04 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation p Parallel Piping Compact Distribution Point-of Use Recirculation Central DHW Control Distribution DHW Sys 1 - 1/1 __ SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name 1ST FLOOR AREA1 Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 2ND FLOOR AREA2 Other Heating and Cooling System Heating ComponenECoofingt 2 Component 2 HVAC Fan 2 FA,istribution System 2 HVAC - HEATING UNIT TYPES 01 02 03 Name Type Heating Component 1 CntrlFurnace - Fuel-fired central furnace Efficiency Heating Component 2 CntrlFurnace - Fuel-fired central furnace 80 AFUE 80 AFUE HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 Efficiency Name System Type EER SEER Zonally Controlled Multi-speed Compressor HERS Verification Cooling Component 1 SplitAirCond 12.2 14 Not Zonal Single Speed Cooling Component 1-hers-cool Cooling Component 2 SplitAirCond 12.2 14 Not Zonal Single Speed Cooling Component 1-hers-cool Registration Number: 215-N0214527A-000000000-0000 Registration Date/Time: 2015-08-03 16:11:24 HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 CaICERTS inc. Report Generated at: 2015-08-03 16:06:42 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: SINGLE HOUSE Calculation Date/Time: 16:05, Mon, Aug 03, 2015 Calculation Description: Title 24 Analysis Input File Name: R15-3933.xm1 HVAC COOLING - HERS VERIFICATION 01 Name Cooling Component 1 -hers -cool Cooling Component 2 -hers -cool HVAC - DISTRIBUTION SYSTEMS 01 02 CF1 R -PRF -01 Page 7 of 9 02 03 Airflow Target 04 05 06 Verified Airflow Verified EER Verified SEER Verified Refrigerant Charge Required 350 Required q Not Required Required Required 350 Required Not Required Required 03 I 04 Duct Insulation R -value Name Type Supply Return Air Distribution System 1 DuctsAttic 8 8 Air Distribution System 2 DuctsAttic 8 HVAC DISTRIBUTION - HERS VERIFICATION 01 02 Duct Leakage Name Verification Air Distribution System 1 -hers -dist Required Air Distribution System 2 -hers -dist Required HVA FAN SYSTEMS 01 Name HVAC Fan 1 HVAC Fan 2 HVAC FAN SYSTEMS - HERS VERIFICATION 01 8 03 Duct Leakage Target (%) 6.0 6.0 05 I 06 Duct Location Supply Return Attic Attic Attic ) Attic 04�Verified 10 Verified Du Location Design NotRequired Required Not Required Required 02 Type Single Speed PSC Furnace Fan Single Speed PSC Furnace Fan 07 I 08 Duct Surface Area Supply Return 06 Buried Ducts Not Required Not Required 03 Fan Power (Watts/CFM) 0.58 0.58 02 Name Verified Fan Watt Draw Registration Number: 215-N0214527A-000000000-0000 Registration Date/Time: 2015-08-03 16:11:24 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 09 10 HERS Bypass Duct Verification Air Distribution None System 1 -hers -dist Air Distribution None System 2 -hers -dist 07 Deeply Buried Ducts Not Required Not Required 08 Low -leakage Air Handler 04 HERS Verification HVAC Fan 1 -hers -fan HVAC Fan 2 -hers -fan 03 Required Fan Efficiency (Watts/CFM) HERS Provider: CaICERTS inc. Report Generated at: 2015-08-03 16:06:42 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: SINGLE HOUSE Calculation Date/Time: 16:05, Mon, Aug 03, 2015 Calculation Description: Title 24 Analysis Input File Name: R15-3933.xm1 HVAC Fan 1 -hers -fan �Reqwred HVAC Fan 2 -hers -fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EEEEEE� IAQ (Indoor Air Quality) FANS 01 02 03 04 05 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Recovery IAQ Fan Type Effectiveness(%) SFam IAQVentRpt 74.77 0.25 Default p 0.58 0.58 CF1 R -PRF -01 Page 8 of 9 06 HERS Verification Required Registration Number: 215-No214527A-000000000-0000 Registration Date/Time: 2015-08-03 16:11:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-03 16:06:42 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: SINGLE HOUSE Calculation Date/Time: 16:05, Mon, Aug 03, 2015 Calculation Description: Title 24 Analysis Input File Name: R15-3933.xm1 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Raymond Zhong Company: Perfect Design Address: 2416 W. Valley Blvd. City/State/Zip: Alhambra, CA 91803 Documentation Author Signature: Signature Date: 2015-08-03 16:11:24 CEA/HERS Certification Identification (if applicable): Phone: 6262898808 CF1 R -PRF -01 Page 9 of 9 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Raymond Zhong Company: Date Signed: Perfect Design 2015-08-03 16:11:24 Address: 2416 W. Valley Blvd. License: M-27635 City/State/Zip: Phone: Alhambra, CA 91803 6262898808 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 215-N0214527A-000000000-0000 Registration Date/Time: 2015-08-03 16:11:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFIR-07082015-744 Report Generated at: 2015-08-03 16:06:42 RESIDENTIAL MEASURES SUMMARY Project Name RMS -1 SINGLE HOUSE Building Type m Single Family ❑Addition Alone Project Address ❑Multi Family ❑ Existin + 9 Addition/Alteration Date 8/3/2015 10381 BRET AVE. CUPERT/N0 California Energy Climate Zone Total Cond. Floor Area Addition CA Climate Zone 04 # of Units INSULATION - 3, 727 n�a 1 Construction Construction Type CavityArea ( ) S ecial Features Wood Framed Attic Status Wall Wood Framed R38 2,599 New Floor Wood Framed w/Crawl Space R21 1,704 Wall Wood Framed R 19New 2,434 New Demising Wood Framed w/o Crawl Space R21 1,220 New Rig 1,293 New FENESTRATION Total Area: Orientation Area(ft) ( ) U -Fac 757 GlazingPercents e: 20.3 / SHGC New/Altered Average U -Factor: 0.31 Skylight 18.0 Overhan Sidefins Exterior Shades Status 0.510 Rear (W) 0.26 none none None 287 .10.300 0.300 Front (E) 191.0 0.32 none none Bug Screen 0.300New Right (N) 112.7 0.32 none none Bug Screen New 0.300 Left (S) 130.4 0.32 none none Bug Screen New 0.300 Skylight 18.0 0.32 none none Bug Screen New 0.510 0.26 none none None New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff 1 Central Furnace 80% AFUE Split Air Conditioner Thermostat Status 1 Central Furnace o 80% AFUE 14.0 SEER Split Air Conditioner Setback New 14.0 SEER Setback New HVAC DISTRIBUTION Location Heati 1ST FLOOR AREA Ducted 2ND FLOOR AREA Ducted WATER HEATING 1 Small Storage Gas Coolina Duct Location Ducted Attic Ducted Attic Gallons Min. Eff Distribution 75 0.69 Standard 6 by EnergySoft User Number 1919 RunCode 20,15 -OS -03T16:09:21 Duct R -Value Status 8.0 New 8.0 New Status New 2013 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. Exceptions may apply. Review the respective code section for more information_ Building Envelope Measures: § 110.6(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. § 110.6(a)5: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets therequirements of 10-111 a . § 110.7: Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed. § 110.8(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R. § 110.8(i): The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the installation of a cool roof is specified on the CFI R. §110.80): A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFIR. §150.0(a): Minimum R-30 insulation in wood -fame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The attic access shall be gasketed to prevent air leakage. §150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -value. § 150.0(c): Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U - factor). -§150.0(d): Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor. § 150.0(g)l: In Climate Zones 14 and 16 a Class 11 vapor retarder shall be installed on the conditioned space side of all insulation in all exterior walls, vented attics and unvented attics with air -permeable insulation. § 150.0(8)2: In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class I1 vapor retarder. In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of § 150.0(g)3: the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section 150.0(d). § 150.0(1): Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration: and when installed as part of a heated slab floor meets therequirements of § 110.8 § 150.0(q): Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U - factor of 0.58; or the weighted averse U -factor of all fenestration shall not exceed 0.58. Fireplaces, Decorative Gas Appliances and Gas Log Measures: §150.0(e)IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e) I B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible operable, and tight -fitting damper or a combustion -air control device. § 150.0(e)IC: Masonry or factory -built fireplaces have a flue damper with a readily accessible control. § 150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building,are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission. § 110.3(c)5: Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of § 110.3(c)5. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli- § 110.5: antes without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool And spa heaters. § 150.0(h)1: Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified in §150.0(h)2. § 150.0(h)3A: Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any dryer vent. §150.0(1): Heating systems are equipped with thermostats that meet the setback requirements of §I 10.2(c). §150.06)IA: Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped with insulation having an installed thermal resistance of R-12 or geater. §150.06)IB: Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system §150.00)2A: regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3- A. § 150.06)2B: All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve that allows for installation, removal, and replacement of the enclosed nine and insulation. 2013 Low -Rise Residential Mandatory Measures Summary § 150.06)2C: Pipe for cooling system lines shall be insulated as specified in §I50.00)2A. Piping insulation for steam and hydronic heating systems or hot waters stems with pressure > 15 psig shall meet therequirements in TABLE 120.3-A. § 150.00)3: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For §150.00)3A: example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or painted with coating that is water retardant and provides shielding from solar radiation that degrades the material. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I §150.00)3B: or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor retarder. Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the §150.0(n)l: space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. §150.0(n)2: Recirculating loops serving multiple dwelling units shall meet the requirements of §I10.3(c)5. § 150.0(n)3: Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC) or by a testing enc approved by the Executive Director. Ducts and Fans Measures: All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0, §603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC §605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed § 150.0(m)1: with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 18 IA, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than %. inch, the combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints § 150.0(m)2: and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. § 150.0(m)3-6: Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling. §150.0(m)7: All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § 150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible manually operated dampers except combustion inlet and outlet air openings and elevator shaft vents. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not § 150.0(m)9: limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. §150.0(m)10: Flexible ducts cannot have porous inner cores. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be §150.0(m)11: sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential A endix RA3. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal §150.0(m)12: conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of 150.0(m) 12. Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the §150.0(m)13: placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode, §150.0(m)15: an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of>_ 350 CFM per ton of nominal cooling capacity, and operating at an air -handling unit fan efficacy of <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing,in accordance with Reference Residential Appendix RA3. All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of §150.0(o): central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the Whole Building Ventilation. §150.0(o)IA: Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Pool and Spa Heating Systems and Equipment Measures: Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency § 1 10.4(a): Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat - settin ; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating. 2013 Low -Rise Residential Mandatory Measures Summary § 110.4(b)l: Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction and return lines or built-up connections for future solar heating. § 110.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. § 110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro - ed to run only during off-peak electric demand periods. § 110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light. § 150.0(p): Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements. Lighting Measures: § 110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9. §150.0(k)IA: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §150.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B, as applicable. §150.0(k)1B: When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply with the applicable provisions of § 150.0(k). The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with § 150.0(k)] C: § I30.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180 watts of low efficacy lighting er electrical box. §150.0(k)ID: Ballasts for fluorescent lamns rated 13 watts nr or rater shaft hP -A oU.,n U.,..e Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no § 150.0(k)IE: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vacancy sensors. § 150.0(k)] F: Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable requirements of § 150.0(k). § 150.0(k)2A: High efficacy luminaires must be switched separately from low efficacy luminaires. § 150.0(k)2B: Exhaust fans shall be switched separately from lighting systems. § 150.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Controls and equipment are installed in accordance with manufacturer's instructions. § 150.0(k)2E: No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § I50.0(k). § 150.0(k)2F: Lighting controls comply with applicable requirements of § 110.9. An Energy Management Control System (EMCS) may be used to complywith dimmer requirements if it functions as a dimmer § 150.0(k)2G: according to §110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in §150.0(k)2. An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § 150.0(k) if: it § 150.0(k)2H: functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in &I50.0 2. § ] 50.0(k)2I: A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2. § 150.0(k)3A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high effi racy. § 150.0(k)3B: Kitchen fighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are considered kitchen lighting if they are not separately switched from kitchen lighting. § 150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. § 150.0(k)5: A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. § I50.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. § 150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing § 150.0(k)8: and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and allow ballast maintenance and replacement without requiring cutting holes in the ceiling. For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § 150.0(k), the ballasts shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9. For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and § 150.0(k)9A: ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours; and iii. Controlled by one of the following methods: 2013 Low -Rise Residential Mandatory Measures Summary a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the § 150.0(k)9B: following requirements: i. Shall comply with §150.0(k)9A; or ii. Shall comply with the applicable requirements in 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0. § 150.0(k)9C: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D shall comply with the applicable requirements in § 110.9 130.0 § 130.2 § 130.4 § 140.7 and § 141.0. § 150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shal l comply with the applicable requirements in § 110.9, § 130.0, § 13 0.2, § 130.4 § 140.7 and § 141.0. § 150.0(k)10: Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined according to § 130.0(c). § 150.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in § 110.9 130.0, § 130. 1, § 130.4, § 140.6, and § 141.0. In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of § 150.0(k) I2A: the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: § 150.0(k)12B: i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of' ingress and egress. Solar Ready Buildings: Single family residences located in subdivisions with ten or more single family residences and where the application for a § 110.10(a)1: tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014. shall comply with the requirements of § 110.10 through 110.10 e . § 110.10(a)2: Low-rise multi -family buildings shall comply with the requirements of § 110.10(b) through § 110.10(d). The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for §110.10(b)l: buildings with roof areas greater than 10,000 square feet. For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. § 110.10(b)2: All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be located in the solar zone. Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice § 110.10(b)3B: the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal ro;e on of the nearest point of the solar zone, measured in the vertical plane. § 110.10(b)4: For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly indicated on the construction documents. The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit § 110.10(c): from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c) shall be provided to the occupant. § 110.10(e)l: The main electrical service panel shall have a minimum busbar rating of 200 amps. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a § 110.10(e)2: future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or main circuit location, and permanently marked as "For Future Solar Electric'. HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name SINGLE HOUSE Date 8/3/2015 System Name 1ST FLOOR AREA Floor Area 2,434 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,018 Return Vented Lighting Return Air Ducts Return Fan Ventilation 6 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 95,200 24,730 1,089 523 20,605 Total Output (Btuh) 95,200 0 Outside Air (%) I Output Btuh/s ft 39.1 965 976 -Cooling System 0 0 Output perSystem 57,000 0 0 0 0 Total Output Btuh 57,000 0 1,089 0 Total Output (Tons) 4.8 965 976 Total Output (Btuh/s ft) 23.4 Total Output s ft/Ton 512.41 26,660 22,557 Air System ROOM CFM per System 1,vtu HVAC EQUIPMENT SELECTION 78/62°F 55/54°F Airflow cfm 1,970 CARRIER 24ABB360/58CVA-155-22 (5 TON) 46,537 8,175 95,200 Airflow cfm/s ft 0.81 Outside Air Airflow (cfm/ron) 414.7 0 cfm Cooling Coil Supply Fan 55 / 54 OF Outside Air (%) I Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 46,537 8,175 Aug 3 PM 95,200 Jan 1 AM –0.0% Outside Air cfm/ ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 28 OF 68 OF 105 °F105 OF i Outside Air 0 cfm Heating Coil Supply Fan 1,970 cfm 105 IF ROOM 68 IF 68 OF COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak) 88/68°F 78/62°F 55/54°F 55/54°F Outside Air 0 cfm Cooling Coil Supply Fan 55 / 54 OF 1,970 cfm 41.0%ROOD 11� In 78 ! 62 OF 4 F—T 4 78 / 62 OF EnergyPro 6.6 by EnergySofr User Number: 1919 RunCode• 2015-08-03T16.09.21 ID: R15-3933 Page 17 of 24 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name SINGLE HOUSE Dale 8/3/2015 System Name 2ND FLOOR AREA Floor Area 1,293 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 369 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD 1 COOLING PEAK COIL HTG. PEAK -Heating System Sensible Latent CFM Sensible Output per System 68,000 9,043 851 231 9,139 Total Output (Btuh) 68,000 0 433 Output Stuh/s ft 52.6 353 Cooling System 0 0 Output per System 33,400 0 0 0 0 Total Output Btuh 33,400 0 851 0 Total Output (Tons) 2.8 353 433 Total Output (Btuh/s ft) 25.8 Total Output s ft/Ton 464.6 9,749 10,005 Air System CFM per System i,,euu HVAC EQUIPMENT SELECTION Airflow (cfm) 1,200 CARRIER 24ABS336/58CVA-110-20 (3 TON) 27,505 4,556 '}✓��_ Outside AirAr 68,000 Airflow (cfm/s ft) 0.93 1,200 cfm 41.2% ROOM 78 / 62 OF Airflow (cfm/Ton) 431.1 Outside Air (%) 0.0% Total Adjusted System Output 27,505 4,556 68,000 (Adjusted for Peak Design conditions) Outside Air (cfm/s ft) 0.00 Note. values above given at ARI conditions ITIME OF SYSTEM PEAK I Aug 3 PM1 IJan 1 AM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 28 IF 68 OF 105 T 105 OF Outside Air 0 cfm Heating Coil Supply Fan 1,200 cfm 105 IF ,,............... .,.-_............. . . ROOM 68 °F 68 OF COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak) 88/68°F 78/62°F 55!54°F 55/54T .. POP A _—�—Lifl '}✓��_ Outside AirAr 0 cfm AL Cooling Coil Supply Fan 55 / 54 IF 1,200 cfm 41.2% ROOM 78 / 62 OF 781 62 °`r �EnergyPro 6 6 by EnergySoft User Number 1919 RunCode: 2015-08-03716.09.21 /D R15-3933 Paqe 18 of 24 ROOM LOAD SUMMARY Project Name Date SINGLE HOUSE 8/3/2015 System Name Floor Area 1ST FLOOR AREA 2,434 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK I COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible 1STFLOORPLAN 1ST FLOOR PLAN 1 1,018 24,730 1,089 1,018 24,7301 1,0891 5231 20,605 PAGE TOTAL TOTAL* I ' Total includes ventilation load for 110,81 24,7301 1,0895231 20,605 F1,018 F 24,7301 1,089 F523 20, 605 i —c yy,-,u u uy cneigyoun userwumoer: 7a7a munE;we: 2075-08-03T16:09:21 ID R15-3933 Page 19 of 24 ROOM LOAD SUMMARY Project Name SINGLE HOUSE Date 8/3/2015 System Name 2ND FLOOR AREA Floor Area 1,293 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible 2ND FLOOR PLAN 2ND FLOOR PLAN 1 369 9,043 851 369 9,043 851 231 9,139 Total includes ventilation load for zonal systems. EnergyPro6.6b Ener Soft User Number. 1919 PAGE TOTAL TOTAL * RunCode:2015-OR-03r1Br09.91 369 9,043 851 369 9,043 851 231 9,139 231 9,139 ROOM HEATING PEAK LOADS Project Name SINGLE HOUSE ROOM INFORMATION DESIGN CONDITIONS Room Name 1ST FLOOR PLAN Time of Peak Floor Area 2,434.0 ft2 Outdoor Dry Bulb Temperature Indoor Dry Bulb Temperature 68 OF Conduction Area R-38 Roof Attic 1,324.0 ) Double Metal Clear... 18.0 ) R-21 Wall 1,704.3 ) Double Non Metal Clear (6) 552.9 R-19 Floor W/Craw/space 2,434.0 11 x x x x x x x x x x x x x x x x x X X X X X X X X Items shown with an --id, ` d U -Value AT °F 8/3/2015 Jan 1 AM 28 OF Btu/hr 1,324 367 4,704 6,635 3,6021 s ( ) enote conduction through an interior surface to another room Page Total L 16,632 Infiltration:[ 1.00 x 1.077 x 2,434 x 9.00 x 0.253 /60] X 40 = 3,973 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 20,605 i -„C yyr.ru o.o oy cnergy,�ion user Number. 1919 RunCode 2015-08-03716 09 21 ID: R15 3933 Pape 21 of 24 ROOM HEATING PEAK LOADS Project Name SINGLE HOUSE ROOM INFORMATION DESIGN CONDITIONS Room Name 2ND FLOOR PLAN Time of Peak Floor Area 1,293.0 ft2 Outdoor Dry Bulb Temperature Indoor Dry Bulb Tem erature 68 OF 8/3/2015 Jan 1 AM 28 OF LnergyPro 6.6 by EnergySoft User Number: 1919 RunCode: 2015-08-03716:09:21 ID: R15-3933 pan'. 99 nf 7d Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 40 Btu/hr R-38 Roof Attic 1,275.0 0.0250 40 1,275 Double Metal Clear.. 18.0 0.5100 40 367 R-21 Wall 1,219.7 0.0690 40 31366 Double Non Metal Clear (6) 168.3 0.3000 40 2,020 *R-19 Floor W/O Crawlspace 1,092.0 0.0490 0 0 Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.077 Schedule Air Sensible Fraction through an interior surface X 1,293 X Area another room 9.00 X 0.253 Height ACH Page Total /60] X AT 7,028 = 2,110 TOTAL HOURLY HEAT LOSS FOR ROOM 9,139 LnergyPro 6.6 by EnergySoft User Number: 1919 RunCode: 2015-08-03716:09:21 ID: R15-3933 pan'. 99 nf 7d RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date SINGLE HOUSE 8/3/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name 1ST FLOOR PLAN Outdoor Dry Bulb Temperature 88 OF Floor Area 2,434.0 ft' Outdoor Wet Bulb Temperature 68 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 30 OF Opaque Surfaces Orientation Area -U-Factor CLTD' Btu/hr R-38 Roof Attic (N) 1,324.0 X 0.0250 X 37.0 = 1,225 R-21 Wall (W 304.3 X 0.0690 X 13.0 = 273 R-21 Wall (E) 406.2 X 0.0690 X 13.0 = 364 R-21 Wall (N) 482.0 X 0.0690 X 3.0 = 100 R-21 Wall (S) 511.8 X 0.0690 X 6.0 = 212 R-19 FloorW/Crawlspace 2,434.0 X 0.0370 X 4.0 = 360 X X = X X = X X = Page Total 2,534 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Skylight (N) 0.0 X 10.3 + 18.0 X 46.9 = 844 WINDOWS (W) 0.0 X 12.9 + 225.0 X 32.4 = 7,292 WINDOWS (E) 0.0 X 12.9 + 141.4 X 32.4 = 4,583 WINDOWS (N) 0.0 X 12.9 + 91.5 X 12.9 = 1,184 WINDOWS (S) 0.0 X 12.9 + 95.0 X 17.8 = 1,688 X + X = X + X = X + X = X + X = Page Total 15,591 Internal Gain Btu/hr -Occupants 7.3 Occupants X 245 Btuh/occ. = 1,789 Equipment 2,434 Floor Area X 0.50 w/g4 ft = 4,154 Infiltration: 1.077 X 0.61 X 100.39 X 10 = 663 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 24,730 Latent Gain Btu/hr Occupants 73 Occupants X 155 Btuh/occ. = 1,132 Infiltration: X 0.61 X 100.39 X -0.00015 = -43 Sensible Air Sensible CFM ELA Dye/ TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 832 Ener Pro 6.6 by Ener Soft User Number. 1919 RunCode: 2015-08-o3T16r09.91 1 IV RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date SINGLE HOUSE 8/3/2015 ROOM INFORMATION DESIGN CONDITIONS Room Name 2ND FLOOR PLAN Outdoor Dry Bulb Temperature 88 °F Floor Area 1, 293.0 ft' Outdoor Wet Bulb Temperature 68 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 30 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr R-38 RoofAttic (N) 1,275.0 X 0.0250 X 37.0 = 1,179 R-21 Wall (149 279.9 X 0.0690 X 13.0 = 251 R-21 Wall (E) 292.4 X 0.0690 X 13.0 = 262 R-21 Wall (N) 330.8 X 0.0690 X 3.0 = 68 R-21 Wall (S) 316.6 X 0.0690 X 6.0 = 131 'R-19 Floor W/0 Crawlspace 1,092.0 X 0.0490 X 0.0 = 0' X X = X X = X X = Page Total 1,892 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Skylight (N) 0.0 X 10.3 + 18.0 X 46.9 = 844 WINDOWS (W) 0.0 X 12.9 + 62.1 X 32.4 = 2,013 WINDOWS (E) 0.0 X 12.9 + 49.6 X 32.4 = 1,608 WINDOWS (N) 0.0 X 12.9 + 21.2 X 12.9 = 274 WINDOWS (S) 0.0 X 12.9 + 35.4 X 17.8 = 629 X + X = X + X = X + X = X I + LX = Page Total 5,36 Internal Gain Btu/hr Occupants 3.9 Occupants X 255 Btuh/occ.=L 990 Equipment 1,293 Floor Area X 0.10 w/s4 ft = 441 Infiltration: X 0.61 X 53.33 X 10 = 352 Sensible Air Sensible CFM EtA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM Latent Gain Btu/hr Occupants 3.9 Occupants X 225 Btuh/occ. = 874 Infiltration: 4,830 X 0.61 X 53.33 X -0.00015 = 23 Air Sensible CFM ELA AW I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM r, L EnergyPro 6.6 by EneMySoft User Number 1919 RunCode- 2015-08-03T16.09.21 ID R15-3933_ Paae 24 of 24