15080067CITY OF CUPERTINO BUILDING PERMIT
BUILDING ADDRESS: 10257 GLENCOE DR
CONTRACTOR: TRACY HSU
PERMIT NO: 15080067
OWNER'S NAME: TRACY HSU
22333 SANTA PAULA AVE
DATE ISSUED: 10/01/2015
OWNER'S PHONE: 4084645030
CUPERTINO, CA 95014-2835
PHONE NO:
❑ LICENSED CONTRACTOR'S DECLARATION
JOB DESCRIPTION: RESIDENTIAL ❑ COMMERCIAL
CONSTRUCT (N) 2 STORY SFD (3727 S.F.) COVERED
License Class Lic. #
PORCH (616 S.F.) WITH ATTACHED GARAGE (489 S.F.)
Contractor Date
I hereby affirm that I am licensed under the provisions of Chapter 9
(commencing with Section 7000) of Division 3 of the Business & Professions
Code and that my license is in full force and effect.
I hereby affirm under penalty of perjury one of the following two declarations:
Sq. Ft Floor Area:
Valuation: $700000
t. I have and will maintain a certificate of consent to self -insure for Worker's
Compensation, as provided for by Section 3700 of the Labor Code, for the
APN Number: 32630016.00
Occupancy Type:
performance of the work for which this permit is issued.
2. I have and will maintain Worker's Compensation Insurance, as provided for by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued.
PERMIT EXPIRES IF WORK IS NOT STARTED
APPLICANT CERTIFICATION
WITHIN 180 DAYS OF PERMIT ISSUANCE OR
I certify that I have read this application and state that the above information is
180 DAYS FROM LAST CALLED INSPECTION.
correct. I agree to comply with all city and county ordinances and state laws relating
to building construction, and hereby authorize representatives of this city to enter
upon the above mentioned for inspection
property purposes. (We) agree to save
Issued by: Date:
indemnify and keep harmless the City of Cupertino against liabilities, judgments,
costs, and expenses which may accrue against said City in consequence of the
granting of this permit. Additionally, the applicant understands and will comply with
all non -point source regulations per the Cupertino Municipal Code, Section 9.18.
RE -ROOFS .
All roofs shall be inspected prior to any roofing material being installed. If a roof is
Signature Date
installed without first obtaining an inspection, I agree to remove all new materials for
inspection.
Signature of Applicant: Date:
OWNER -BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for one of
ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER
the following two reasons:
t. I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for
HAZARDOUS MATERIALS DISCLOSURE
sale (Sec.7044, Business & Professions Code)
I have read the hazardous materials requirements under Chapter 6.95 of the
I, as owner of the property, am exclusively contracting with licensed contractors to
California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain
construct the project (Sec.7044, Business & Professions Code).
compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health &
Safety Code, Section 25532(a) should I store or handle hazardous material.
I hereby affirm under penalty of perjury one of the following three declarations:
Additionally, should I use equipment or devices which emit hazardous air
t. I have and will maintain a Certificate of Consent to self -insure for Worker's
contaminants as defined by the Bay Area Air Quality Management District I will
Compensation, as provided for by Section 3700 of the Labor Code, for the
maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the
performance of the work for which this permit is issued.
2. I have and will maintain Worker's Compensation Insurance, as provided for by
Health & Safety Code, Sections 25505, 25533, and 25534.
Owner or autl 'i'zed a4
Section 3700 of the Labor Code, for the performance of the work for which this
Date:
permit is issued.a
s. 1 certify that in the performance of the work for which this permit is issued, I shall
/CONSTRUCTION LENDING AGENCY
not employ any person in any manner so as to become subject to the Worker's
I hereby affirm that there is a construction lending agency for the performance of work's
Compensation laws of California. If, after making this certificate of exemption, I
for which this permit is issued (Sec. 3097, Civ C.)
become subject to the Worker's Compensation provisions of the Labor Code, I
Lender's Name
must forthwith comply with such provisions or this permit shall be deemed
revoked.
Lender's Address
APPLICANT CERTIFICATION
ARCHITECT'S DECLARATION
I certify that I have read this application and state that the above information is
I understand my plans shall be used as public records.
correct. I agree to comply with all city and county ordinances and state laws relating
to building construction, and hereby authorize representatives of this city to enter
Licensed Professional
upon the above mentioned property for inspection purposes. (We) agree to save
indemnify and keep harmless the City of Cupertino against liabilities, judgments,
costs, and expenses which may accrue against said City in consequence of the
granting of this permit. Additionally, the applicant understands and will comply with
all non -point source regulations per the upeitino Municipal Code,Section9.18.
Signature Date{
CITY OF CUPERTINO 1503W6,R_ -
FF,F, FqTl[-N4 A Tn1D — RITTY 7MTVI_' "1X71rQTd'%XT
1AADDRESS: 10267 GLENCOE DR.
TYPE OF
CONSTR.
DATE: 08/07/2015
REVIEWED BY: PAUL
APN: 326 30 016
BP FEES
BP FEE ID
*VALUATION: 1$700,000 j
11-B,111-B,1V,V-B
4,832
$3,342.57
JR3PLNCK
*PERMIT TYPE: Building Permit
PLAN CHECK TYPE: New Construction
FRMARY SFD Duplex 2nd Unit? 0 Yes E) No PENTAMATION
USE: or I
PME Plan Check:
PERMIT TYPE: 1 R3SFDW
WORK Construct (N) 2 story SFD (3727 S.F. Covered Porch (616 S.F. with Attached Garage (489 S.F.
SCOPE
OCCUPANCY TYPE:
TYPE OF
CONSTR.
FLR AREA
(s.f.)
PC FEES
PC FEE ID
BP FEES
BP FEE ID
R-3 (Custom)
11-B,111-B,1V,V-B
4,832
$3,342.57
JR3PLNCK
$4,037.37
IR3INSP
$0.00
PME Plan Check:
$0.00
Permit Fee:
$4,037.37
Suppl. Insp. Feer Reg. 0
OT
F—O0
hrs
$0.00
PME Unit Fee:
$0.00
PME Permit Fee:
TOTALS:
4,832
$3,342.57
-7
$4,037.37
—$0.00
1
I Plan 0qeck
tech. Per Fee:
Phonb. Man C'heck
1111(mb, Per n,,;r Fe(c:
E'/eo, Man Check
1.7(.,C. Ilernlit Fee:
Other UeJi, Jnsj.>, Other 11howbbi-s-p. Oilier Ele", In -11,10.
Hoch. hn"). Fee: Mnmb. Imp. Fee: Elec. Insp. Foe:
NOTE.* This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanh
District, School
District. etc.). f7,ffih,Dont fir Al"91i.Aq
FEE ITEMS (Fee Resolution .1.7-053 Eff. 711113)
FEE
QTY/FEE
MISC ITEMS
Plan Check Fee:
$3,342.57
Select a Misc Bldg/Structure
or Element of a Building
Su 1. PC Fee: •Q) Reg. 0 OT I
_00
hrs
$0.00
PME Plan Check:
$0.00
Permit Fee:
$4,037.37
Suppl. Insp. Feer Reg. 0
OT
F—O0
hrs
$0.00
PME Unit Fee:
$0.00
PME Permit Fee:
Construction Tax: IBCONSTAXRF
—$0.00
1
# new 1 units
$684.98
_4thnini_slraflve Fee:
0
(9
Work Without Permit? Cl Yes (E) No
$0.00
Advanced. Planning Fee.
IPLLONGR
$676.481
Select a Non -Residential
Building or Structure
E)
0
Strong Motion Fee:
IBSEISMICR
$91.00
Select an Administrative Item
Bldg Stds Commission Fee: IBCBSC
j $28.00
$8,860.40
$0.00
TOTAL F,
1
$8,860.400
Revised: 07/02/2015
CONSTRUCTION PERMIT APPLICATION
COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION
10300 TORRE AVENUE • CUPERTINO, CA 95014-3255
I (408) 777-3228 • FAX (408) 777-3333 • building d)cupertino.org
�t,�Ir� RT'No
(=! NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION / TI ❑ REVISION / DEFERRED ORIGINAL PERMIT #
PROJECT ADDRESS
i �b
APN # "p
L
SI2
�
OWNER NAME gg j _ ry �-� PHONE
�i .m '°'� �
E-MAIL /_
�i' •'K. P< ,mss 3 i �gdi�`i� n
STREET ADDRESS 4CITY,
STATE, ZIP
e,4 01
FAX
CONTACT NAME • s
PHONE
to � ..
E-MAIL
���
k,
S BEET ADDRESS CITY, STATE, ZIP
FAXg
❑ OWNER ❑ OWNER-BUII,DER ❑ OWNER AGENT ❑ CONTRACTOR ❑ CONTRACTOR AGENT CHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT
CONTRACTOR NAME
LICENSE NUMBER
LICENSE TYPE
BUS. LIC #
COMPANY NAME
E-MAIL
FAX
STREET ADDRESS
CITY, STATE, ZIP
PHONE
CHITECT GINIEER NAME
LICENSE NUMBER i�
enA
BUS. LIC #
COMPANY NAME
E-MAIL
FAX
STREET ADDRESS
CITY, STATE, ZIP
PHONE
DESCRIPTION OF WORK OLL
9
EXISTING US
�q
PROPOS
USE - CONSTR.
TYPE
, g
i�
# STORIES
USE TYPE OCC.
SQ.FT.
VALUATION ($)
EXISTG
AREA '
NEW FLOOR
AREA ';1-�
DEMO
AREA [ 0 06
TOTAL ,✓{
NET AREA ' "�( q tl li s
8
BATHROOM
REMODELAREA k
KITCHEN
REMODELAREA 1 f�a.
OTHER
REMODEL AREA i )/A
�,P_ 0 C> L;
PORCH AREA.
DECK AREA
TOTAL DECK TORCH AREA
GARAGE AREA: DETACH
J
r3❑YES
#DWELLINGUNITS:
IS A SECOND UNIT
SECONDSTORf El YES
BEING ADDED? UPO
ADDITION? hl -1 N.9
PRE -APPLICATION t219ES IF YES, PROVIDE COPY OF
IS THE BLDG AN ❑ YESEDB,, _
TOTAL VALUATION:
PLANNINGAPPL# NO PLANNING AP TF
EICHLERHOME? NO �` -
to
By my signature below, I certify to each of the following: I am the property owner authorized agent to act on the property OWner's behalf. I have -this
application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local
ordinances and state laws relating to buildin construction. I authorize representatives of Cupertino to enter the above -identified property for inspection purposes.
Signature of Applicant/Agent: Date: �! (S.-
SUPPLEMENTAL INFORMATION REQUIREDnP
_PLANCH�CKTYPE ,r,
al e. ,RbIiTINGSLIP s
New SFD or Multifamily dwellings: Apply for demolition permit for
OVEit TIEkCflQNTER
`QgUu DING pLAN REVII ws
_
existing building(s). Demolition permit is required prior to issuance of building
s
k
`
permit for new building.
CI TXP SRE
� ��PLANREiiEW
Bldgs: Provide a completed Hazardous Materials Disclosure
- ST�INDARD
PIJBLIU wgzxs
_Commercial
Form if any Hazardous Materials are being used as part of this project.
f�AitcE <<
PIREDEPT u
Copy of Planning Approval Letter or Meeting with Planning prior to
' z `
Iv7AJOR
[] SAiVTfARybEWER�IviTRICT
_
submittal of Building Permit application.
X
� � �� _ �,�.,
�,❑. �NVIRONIITENTALHEALTH
BldgApp 2011. doe revised 06/21/11
Building Department
City Of Cupertino ✓
ELI] 10300 Torre Avenue
Cupertino, CA 95014-3255
Telephone: 40&777-3228
C U P E RT I N O Fax: 408-777-3333
CONTRACTOR / SUBCONTRACTOR LIST
*Our municipal code requires all businesses working in the city to have a City of Cupertino business license.
NO BUILDING FINAL OR FINAL OCCUPANCY INSPECTION(S) WILL BE SCHEDULED UNTIL THE
GENERAL CONTRACTOR AND ALL SUBCONTRACTORS HAVE OBTAINED A CITY OF CUPERTINO
BUSINESS LICENSE.
I am not using any subcontractors:
Signature
Please check applicable subcontractors and complete the following information:
Date
✓
SUBCONTRACTOR
BUSINESS NAME
BUSINESS LICENSE #
• � • �/.
�.a pili � ��. ate.' draehs �
...•:. uW.
3 4-119 Z -Cl-
*Our municipal code requires all businesses working in the city to have a City of Cupertino business license.
NO BUILDING FINAL OR FINAL OCCUPANCY INSPECTION(S) WILL BE SCHEDULED UNTIL THE
GENERAL CONTRACTOR AND ALL SUBCONTRACTORS HAVE OBTAINED A CITY OF CUPERTINO
BUSINESS LICENSE.
I am not using any subcontractors:
Signature
Please check applicable subcontractors and complete the following information:
Date
✓
SUBCONTRACTOR
BUSINESS NAME
BUSINESS LICENSE #
Cabinets & Millwork
t
3 4-119 Z -Cl-
Cement Finishing
N 1
4-Z+ 0 /
Electrical{-
�
Excavation
AM1 -
Fencing
Flooring / Carpeting
y
Linoleum / Wood
!�-
( ass / Glazing
Heating
Le H ea -1-i t*otA
b c, 16 y'
Insulation
Landscaping
M 12j C
4 a Z i
Lathing
Masonry
(-
Painting / Wallpaper-
A41 1A `�C
Paving
- c
9 RZ
Plastering
' -- e
7j 7j i
Plumbing
'-G -
/-
Roofing
A 52 CJD
g 6 a
Septic Tank
ZPX
r
Sheet Metal
Sheet Rock
S
2
Tile
MX-�
71'
er %Contractor Signature
Date
OWNER -BUILDER DISCLOSURE FORM
COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISION
10300 TORRE AVENUE • CUPERTINO, CA 95014-3255
(408) 777-3228 • FAX (408) 777-3333 • building aa)cupertino.org
Dear Property Owner(s):
An application for a building permit has been submitted in your name listing yourself as the builder of the property
improvements specified at:
SITE ADDRESS, APN 3 Q BP# �L--^
OWNER NAME OWNER ADDR SS add -01-
DESCRIPTION - /F WORK:
- . . . I 1-- j
We are providing you with an Owner -Builder Acknowledgment and Information Verification Form to make you aware of
your responsibilities and possible risk you may incur by having this permit issued in your name as the Owner -Builder. We
will not issue a building permit until you have read, initialed your understanding of each provision, signed, and
returned this form to us at our official address indicated. An agent of the owner cannot execute this notice unless
you, the property owner, obtain the prior approval of the permitting authority.
OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION
(DIRECTIONS: Please read and initial each statement below to signify you understand or verify this information.)
-lem 1. 1 understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner-
Et—der" building permit that erroneously implies that the property owner is providing his or her own labor and material
personally. I, as an Owner -Builder, may be held liable and subject to serious financial risk for any injuries sustained by
an unlicensed person and his or her employees while working on my property. My homeowner's insurance may not
provide coverage for those injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my
insurance coverage for injuries to workers on my property.
—re2. I understand building permits are not required to be signed by property owners unless they are responsible for
the construction and are not hiring a licensed Contractor to assume this responsibility.
1te
3. 1 understand as an "Owner -Builder" I am the responsible party of record on the permit. I understand that I may
ct myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her
name instead of my own.
*rt4. I understand Contractors are required by law to be licensed and bonded in California and to list their license
numbers on permits and contracts.
5. 1 understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the
t tal value of my construction is at least five hundred dollars ($500), including labor and materials, I may be
considered an "employer" under state and federal law.
6. 1 understand if I am considered an "employer" under state and federal law, I must register with the state and
f eral government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to
unemployment compensation for each "employee." I also understand my failure to abide by these laws may subject
me to serious financial risk.
1r7. 1 understand under California Contractors' State License Law, an Owner -Builder who builds single-family
idential structures cannot legally build them with the intent to offer them for sale, unless all work is performed by
licensed subcontractors and the number of structures does not exceed four within any calendar year, or all of the work
is performed under contract with a licensed general building Contractor.
8. 1 understand as an Owner -Builder if I sell the property for which this permit is issued, I may be held liable for
any financial or personal injuries sustained by any subsequent owner(s) that result from any latent construction
defects in the workmanship or materials.
OwnerBuilderForm 2010.doc revised 04/14/10
1 understand I may obtain more information regarding my obligations as an "employer" from the Internal
4'.
nue Service, the United States Small Business Administration, the California Department of Benefit Payments,
and the California Division of Industrial Accidents. I also understand I may contact the California Contractors' State
License Board (CSLB) at 1-800-321-CSLB (2752) or www.cslb.ca.gov for more information about licensed
contractors.
7 10. 1 am aware of and consent to an Owner -Builder building permit applied for in my name, and understand that I
a the party legally and financially responsible for proposed construction activity at the site address listed above.
11. 1 agree that, as the party legally and financially responsible for this proposed construction activity, I will abide
b all applicable laws and requirements that govern Owner -Builders as well as employers.
12. 1 agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the
nformation l have provided on this form. Licensed contractors are regulated by. laws designed to protect the public. If
you contract with someone who does not have a license, the Contractors' State License Board may be unable to
assist you with any financial loss you may sustain as a result of a complaint... Your only remedy against unlicensed
Contractors may be in civil court. It is also important for you -to understand that if an unlicensed Contractor or
employee of that individual or firm is injured while working on your property, you may be held liable for damages. If
you obtain a permit as Owner -Builder and wish to hire Contractors, you will be responsible for verifying whether or not
those Contractors are properly licensed and the status of their workers' compensation insurance coverage.
CONSTRUCTION LENDING AGENCY
(DIRECTIONS: Please complete the following construction lending agency information.)
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued
(Sec 3097 Civ.)
Lender Name:
Lender Address:
Before a building permit can be issued, this form must be completed and signed by the property owner and
returned to the agency responsible for issuing the permit. Note: A copy of the property owner's driver's license,
form notarization, or other verification acceptable to the city may be required to be presented when the permit is issued
to verify the property owner's signature.
Property Owner's Signature: _ Date: �a
--- - -- - -- --------------------------------------------------------------------------------------------------
(NOTE: The following Authorization Form is required to be completed by the property owner only when designating an
agent of the property owner to apply for a construction permit for the Owner -Builder).
AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF
Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby
authorize the following person(s) to act as my agent(s) to apply for, sign, and file the documents necessary to obtain an
Owner -Builder Permit for my project.
Scope of Construction Project (or Description of Work):
Project Location or Address:
Name of Authorized Agent:
Address of Authorized Agent:
Tel No
I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the
above information and certify its accuracy. Note: A copy of the property owner's driver's license, form notarization, or other
verification acceptable to the city may be required to be presented when the permit is issued to verify the property owners
signature.
Property Owner's Signature:
Date:
OwnerBuilderForm 2010.doc revised 04/14/10
I BUILDING ENERGY ANALYSIS REPORT 1
PROJECT:
SINGLE HOUSE
10381 BRET AVE.
CUPERTINO, CA 95014
Project Designer' C
�epG�nf
SEP 2 5 2015
REVIEVVED SUR C;C?)E
C%UMPI_IANCE
RevieWea gy
Report Prepared by:
PERFECT DESIGN & DEVELOPMENT, INC.
opy
SUBMITTA
Job Number:
R15-3933 BY
Date:
8/3/2015
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
EnergyPro 6.6 by Ener ySoft User Number 1919 /D. R15-3933
F TABLE OF CONTENTS I
Cover Page 1
Table of Contents 2
Form CF -1 R -PRF -01-E Certificate of Compliance 3
Form RMS -1 Residential Measures Summary 12
Form MF -1R Mandatory Measures Summary 13
HVAC System Heating and Cooling Loads Summary 17
Room Load Summary 19
Room Heating Peak Loads 21
Room Cooling Peak Loads 23
6.6
ID: R15-3933
User Number: 1919
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: SINGLE HOUSE Calculation Date/Time: 16:05, Mon, Aug 03, 2015
Calculation Description: Title 24 Analysis Input File Name: R15-3933.xmi
CF1 R -PRF -01
Page 1 of 9
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
04
05
ENERGY USE SUMMARY
06
07
08
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
14.96
11.17
3.79
25.3%
Space Cooling
IAQ Ventilation
8.84
0.93
12.24
0.93
-3.40
0.00
-38.5%
0.0%
Water Heating
8.14
6.97
1.17
14.4%
Photovoltaic Offset
----
0.00
0.00
Compliance Energy Total
32.87
31.31
1.56
4.7%
Registration Number: 215-N0214527A-000000000-0000 Registration Date/Time: 2015-08-0316:11:24
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744
HERS Provider: CaICERTS inc.
Report Generated at: 2015-08-03 16:06:42
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CF1R-PRF-01
Project Name: SINGLE HOUSE Calculation Date/Time: 16:05, Mon, Aug 03, 2015
Page 2 of 9
Calculation Description: Title 24 Analysis Input File Name: R15-3933.xmi
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Ducts with high level of insulation
• Cathedral Ceiling
• Ceiling has high level of insulation
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Duct Design -Return
• Duct Design -Supply
Domestic Hot Water System Verifications:
• -- None --
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system.
Reference Energy Use I Energy Design Rating
Total Energy (kTDV/f2 yr)* 73.62
72.06
* includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01 1 02 03
Number of Dwelling
Conditioned Floor Area (ft2) Units
3727 1
Project Name
SINGLE HOUSE
04
Number of Bedrooms
4
05
Number of Zones
2
Margin I Percent Improvement
1.56 2.1%
Registration Number: 215-N0214527A-000000000-0000 Registration Date/Time: 2015-08-03 16:11:24
HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744
Report Generated at: 2015-08-03 16:06:42
06
07
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
0
1
Registration Number: 215-N0214527A-000000000-0000 Registration Date/Time: 2015-08-03 16:11:24
HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744
Report Generated at: 2015-08-03 16:06:42
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: SINGLE HOUSE Calculation Date/Time: 16:05, Mon, Aug 03, 2015
Calculation Description: Title 24 Analysis Input File Name: R15-3933.xml
ZONE INFORMATION
01
02
03
04
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft)
1ST FLOOR PLAN
Conditioned
1ST FLOOR AREA1
2434
2ND FLOOR PLAN
Conditioned
2ND FLOOR AREA2
1293
CFI R -PRF -01
Page 3 of 9
OPAQUE SURFACES
05
06
07
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
9
DHW Sys 1
02
Zone
1ST FLOOR PLAN
1ST FLOOR PLAN
1ST FLOOR PLAN
1ST FLOOR PLAN
1ST FLOOR PLAN
1ST FLOOR PLAN
2ND FLOOR PLAN
2ND FLOOR PLAN
2ND FLOOR PLAN
2ND FLOOR PLAN
2ND FLOOR PLAN
9
DHW Sys 1
05
Orientation
Back
Front547.6
Right
Left
Back
Front
Right
Left
OPAQUE SURFACES
05
08
06
Orientatio
n
Area (ft)
Skylight Area
(ft2)
Roof Rise
(x in 12)
01
Name
WEST WALL
EAST WALL
NORTH WALL
SOUTH WALL
R-38 Roof 3
Raised Floor
WEST WALL 2
EAST WALL 2
NORTH WALL 2
SOUTH WALL 2
R-38 Roof 4
02
Zone
1ST FLOOR PLAN
1ST FLOOR PLAN
1ST FLOOR PLAN
1ST FLOOR PLAN
1ST FLOOR PLAN
1ST FLOOR PLAN
2ND FLOOR PLAN
2ND FLOOR PLAN
2ND FLOOR PLAN
2ND FLOOR PLAN
2ND FLOOR PLAN
03
Construction
R-21 Wall
R-21 Wall
R-21 Wall
R-21 Wall
R-38 Roof Attic
R-19 Floor W/ Crawlspace
R-21 Wall
R-21 Wall
R-21 Wall
R-21 Wall
R-38 Roof Attic
04
Azimuth
270
90
0
180
270
90
0
180
05
Orientation
Back
Front547.6
Right
Left
Back
Front
Right
Left
06
Gross Area (ft2)
529.3
573.5
606.8
1324
2434
342
342
352
352
1275
07
Window & Door Area (ft)
225
141.4
91.5
95
62.1
49.6
21.2
35.4
08
Tilt (deg)
90
90
90
90
yo
90
90
90
OPAQUE SURFACES — Cathedral Ceilings
01 02 03
Name Zone Type
R-38 Roof 1ST FLOOR PLAN R-38 Roof Atticl
R-38 Roof 2 2ND FLOOR PLAN R-38 Roof Atticl
04
05
08
06
Orientatio
n
Area (ft)
Skylight Area
(ft2)
Roof Rise
(x in 12)
Right
18.1
18
4
Right
18.1
18
4
Registration Number: 215-N0214527A-000000000-0000 Registration Date/Time: 2015-08-0316:11:24
HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-03 16:06:42
07
08
09
10
11
Roof
Pitch
Roof Tilt
(deg)
Roof
Reflectance
Roof
Emittance
Framing
Factor
0.33
18.43
0.1
0.85
0.07
0.33
1 18.43
0.1
0.85
0.07
Registration Number: 215-N0214527A-000000000-0000 Registration Date/Time: 2015-08-0316:11:24
HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744 Report Generated at: 2015-08-03 16:06:42
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CF7 R -PRF -01
Project Name: SINGLE HOUSE Calculation Date/Time: 16:05, Mon, Aug 03, 2015 Page 4 of 9
Calculation Description: Title 24 Analysis 9
Input File Name: R15-3933.xm1
ATTIC
01 02 03 04 05 06
07 08
Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic 1ST FLOOR PLAN Attic Roof1ST FLOOR PLAN Ventilated q
0.1 0.85 No No
Attic 2ND FLOOR PLAN Attic Roof2ND FLOOR PLAN Ventilated q
0.1 0.85 No No
Registration Number: 215-N0214527A-000000000-0000 Registration Date/Time: 2015-08-03 16:11:24 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744
Report Generated at: 2015-08-03 16:06:42
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: SINGLE HOUSE Calculation Date/Time: 16:05, Mon, Aug 03, 2015
Calculation Description: Title 24 Analysis Input File Name: R15-3933.xml
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06
07
Construction Name Surface Type Construction T Total Cavity Winter Design
Ype Framing R -value U -value Assembly Layers
•
Cavity/ Frame: no insul. / 2x4 Top Chrd
Attic Roof1 ST FLOOR PLAN Attic Roofs Wood Framed Ceilin 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking
9 in. O.C.Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
• Cavity / Frame: R-9.1 / 2x4
• Over Floor Joists: R -2B.9 insul.
• Inside Finish: Gypsum Board
Cavity / Frame: R-38 / 2x4
• Roof Deck: Wood Siding/sheathing/decking
• Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
• Cavity / Frame: R-21 / 2x6
• Exterior Finish: Wood
Siding/sheathing/decking
• Floor Surface: Carpeted
• Floor Deck: Wood Siding/sheathing/decking
• Cavity / Frame: R-19 / 2x6
•
Cavity/ Frame: no insul. / 2x4 Top Chrd
• Roof Deck: Wood Siding/sheathing/decking
• Roofing: Light Roof (Asphalt Shingle)
• Floor Surface: Carpeted
• Floor Deck: Wood Siding/sheathing/decking
• Cavity / Frame: R-19 / 2x6
• Ceiling Below Finish: Gypsum Board
CF1 R -PRF -01
Page 5 of 9
Ceilings (below
R-38 Roof Attic attic) FWFramed Ceiling
R-38 Roof Attic1
R-21 Wall
R-19 Floor W/ Crawlspace
Attic Roof2ND FLOOR PLAN
Cathedral Ceilings I Wood Framed Ceiling
none 0.644
2x4 @ 24 in. O.C. R 38
2x4 @ 24 in. O.C. R 38
Exterior Wails Wood Framed Wall 2x6 @ 16 in. O.C.
Floors Over
Crawlspace Wood Framed Floor 2x6 @ 16 in. O.C.
2x4 Top Chord of Roof Truss @ 24
Attic Roofs Wood Framed Ceiling in. O.C.
R-19 Floor W/O Crawlspace I Interior Floors I Wood Framed Floor I 2x6 @ 16 in. O.C.
BUILDING ENVELOPE - HERS VERIFICATION
01
Quality Insulation Installation (011)
Not Required
WATER HEATING SYSTEMS
01
Name
DHW Sys 1 - 1/1
02
Quality Installation of Spray Foam Insulation
Not Required
R21
R 19,
R19
0.025
0.036
0.066
0.049
0.644
0.048
03
Building Envelope Air Leakage
Not Required
02 03 04
System Type Distribution Type Water Heater
DHW Standard DHW Heater 1
05
Number of Heaters
1
04
ACH @ 50 Pa
06
Solar Fraction (%)
.0%
Registration Number: 215-No214527A-000000000-0000 Registration Date/Time:
2015-08-03 16:11:24 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744
Report Generated at: 2015-08-03 16:06:42
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: SINGLE HOUSE
CF1R-PRF-01
Calculation Date/Time: 16:05, Mon, Aug 03, 2015
Page 6 of 9
Calculation Description: Title 24 Analysis
Input File Name: R15-3933.xml
WATER HEATERS
01 02
03 04 05 06
07 08
Name Heater Element Type
fTankVolume Energy Factor or
Tank Type al)
Tank Exterior
Insulation Standby Loss
DHW Heater 1 Natural Gas
Efficiency Input Rating
R•value (Fraction)
Small Storage 75 0.69 72000-Btu/hr 0 0.04
WATER HEATING - HERS VERIFICATION
01 02
03 04 05
06 07
Name Pipe Insulation
p
Parallel Piping Compact Distribution Point-of Use
Recirculation Central DHW
Control Distribution
DHW Sys 1 - 1/1 __
SPACE CONDITIONING SYSTEMS
01 02
03 04
05 06
SC Sys Name System Type
Heating Unit Name Cooling Unit Name
Fan Name Distribution Name
1ST FLOOR AREA1 Other Heating and Cooling
System Heating Component 1 Cooling Component 1
HVAC Fan 1 Air Distribution System 1
2ND FLOOR AREA2 Other Heating and Cooling
System Heating ComponenECoofingt 2 Component 2
HVAC Fan 2 FA,istribution System 2
HVAC - HEATING UNIT TYPES
01
02
03
Name
Type
Heating Component 1
CntrlFurnace - Fuel-fired central furnace
Efficiency
Heating Component 2
CntrlFurnace - Fuel-fired central furnace
80 AFUE
80 AFUE
HVAC - COOLING UNIT TYPES
01 02
03 04 05
06 07
Efficiency
Name System Type
EER SEER Zonally Controlled
Multi-speed
Compressor HERS Verification
Cooling Component 1 SplitAirCond
12.2 14 Not Zonal
Single Speed Cooling Component
1-hers-cool
Cooling Component 2 SplitAirCond
12.2 14 Not Zonal
Single Speed Cooling Component
1-hers-cool
Registration Number: 215-N0214527A-000000000-0000
Registration Date/Time: 2015-08-03 16:11:24
HERS Provider:
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Report Version - CF1R-07082015-744
CaICERTS inc.
Report Generated at: 2015-08-03 16:06:42
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: SINGLE HOUSE Calculation Date/Time: 16:05, Mon, Aug 03, 2015
Calculation Description: Title 24 Analysis
Input File Name: R15-3933.xm1
HVAC COOLING - HERS VERIFICATION
01
Name
Cooling Component 1 -hers -cool
Cooling Component 2 -hers -cool
HVAC - DISTRIBUTION SYSTEMS
01 02
CF1 R -PRF -01
Page 7 of 9
02
03
Airflow Target
04
05
06
Verified Airflow
Verified EER
Verified SEER
Verified Refrigerant
Charge
Required
350
Required q
Not Required
Required
Required
350
Required
Not Required
Required
03 I 04
Duct Insulation R -value
Name Type Supply Return
Air Distribution
System 1 DuctsAttic 8 8
Air Distribution
System 2 DuctsAttic 8
HVAC DISTRIBUTION - HERS VERIFICATION
01 02
Duct Leakage
Name Verification
Air Distribution System 1 -hers -dist Required
Air Distribution System 2 -hers -dist Required
HVA FAN SYSTEMS
01
Name
HVAC Fan 1
HVAC Fan 2
HVAC FAN SYSTEMS - HERS VERIFICATION
01
8
03
Duct Leakage
Target (%)
6.0
6.0
05 I 06
Duct Location
Supply Return
Attic Attic
Attic ) Attic
04�Verified
10
Verified Du
Location
Design
NotRequired
Required
Not Required
Required
02
Type
Single Speed PSC Furnace Fan
Single Speed PSC Furnace Fan
07 I 08
Duct Surface Area
Supply Return
06
Buried
Ducts
Not Required
Not Required
03
Fan Power (Watts/CFM)
0.58
0.58
02
Name Verified Fan Watt Draw
Registration Number: 215-N0214527A-000000000-0000 Registration Date/Time: 2015-08-03 16:11:24
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744
09
10
HERS
Bypass Duct
Verification
Air Distribution
None
System
1 -hers -dist
Air Distribution
None
System
2 -hers -dist
07
Deeply Buried
Ducts
Not Required
Not Required
08
Low -leakage
Air Handler
04
HERS Verification
HVAC Fan 1 -hers -fan
HVAC Fan 2 -hers -fan
03
Required Fan Efficiency (Watts/CFM)
HERS Provider: CaICERTS inc.
Report Generated at: 2015-08-03 16:06:42
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: SINGLE HOUSE Calculation Date/Time: 16:05, Mon, Aug 03, 2015
Calculation Description: Title 24 Analysis
Input File Name: R15-3933.xm1
HVAC Fan 1 -hers -fan �Reqwred
HVAC Fan 2 -hers -fan
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EEEEEE�
IAQ (Indoor Air Quality) FANS
01 02 03 04
05
Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Recovery
IAQ Fan Type Effectiveness(%)
SFam IAQVentRpt 74.77 0.25
Default p
0.58
0.58
CF1 R -PRF -01
Page 8 of 9
06
HERS Verification
Required
Registration Number: 215-No214527A-000000000-0000 Registration Date/Time:
2015-08-03 16:11:24 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-07082015-744
Report Generated at: 2015-08-03 16:06:42
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: SINGLE HOUSE Calculation Date/Time: 16:05, Mon, Aug 03, 2015
Calculation Description: Title 24 Analysis Input File Name: R15-3933.xm1
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Raymond Zhong
Company:
Perfect Design
Address:
2416 W. Valley Blvd.
City/State/Zip:
Alhambra, CA 91803
Documentation Author Signature:
Signature Date:
2015-08-03 16:11:24
CEA/HERS Certification Identification (if applicable):
Phone:
6262898808
CF1 R -PRF -01
Page 9 of 9
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name: Responsible Designer Signature:
Raymond Zhong
Company: Date Signed:
Perfect Design 2015-08-03 16:11:24
Address:
2416 W. Valley Blvd. License:
M-27635
City/State/Zip:
Phone:
Alhambra, CA 91803 6262898808
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the
information.
Registration Number: 215-N0214527A-000000000-0000 Registration Date/Time:
2015-08-03 16:11:24 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFIR-07082015-744
Report Generated at: 2015-08-03 16:06:42
RESIDENTIAL MEASURES SUMMARY
Project Name
RMS -1
SINGLE HOUSE
Building Type m Single Family
❑Addition Alone
Project Address
❑Multi Family
❑ Existin +
9 Addition/Alteration
Date
8/3/2015
10381 BRET AVE. CUPERT/N0
California Energy Climate Zone Total Cond. Floor Area Addition
CA Climate Zone 04
# of Units
INSULATION
-
3, 727 n�a
1
Construction
Construction Type
CavityArea
( ) S ecial Features
Wood Framed Attic
Status
Wall Wood Framed
R38 2,599
New
Floor Wood Framed w/Crawl Space
R21 1,704
Wall Wood Framed
R 19New
2,434
New
Demising Wood Framed w/o Crawl Space
R21 1,220
New
Rig 1,293
New
FENESTRATION
Total Area:
Orientation Area(ft)
( ) U -Fac
757 GlazingPercents e: 20.3 /
SHGC
New/Altered Average U -Factor:
0.31
Skylight 18.0
Overhan Sidefins
Exterior Shades
Status
0.510
Rear (W)
0.26 none none
None
287 .10.300 0.300
Front (E) 191.0
0.32 none none
Bug Screen
0.300New
Right (N) 112.7
0.32 none none
Bug Screen
New
0.300
Left (S) 130.4
0.32 none none
Bug Screen
New
0.300
Skylight 18.0
0.32 none none
Bug Screen
New
0.510
0.26 none none
None
New
HVAC SYSTEMS
Qty. Heating Min. Eff
Cooling Min. Eff
1 Central Furnace 80% AFUE
Split Air Conditioner
Thermostat
Status
1 Central Furnace o
80% AFUE
14.0 SEER
Split Air Conditioner
Setback
New
14.0 SEER
Setback
New
HVAC DISTRIBUTION
Location Heati
1ST FLOOR AREA Ducted
2ND FLOOR AREA Ducted
WATER HEATING
1 Small Storage Gas
Coolina Duct Location
Ducted Attic
Ducted Attic
Gallons Min. Eff Distribution
75 0.69 Standard
6 by EnergySoft User Number 1919 RunCode 20,15 -OS -03T16:09:21
Duct
R -Value Status
8.0 New
8.0 New
Status
New
2013 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
compliance approach used. Exceptions may apply. Review the respective code section for more information_
Building Envelope Measures:
§ 110.6(a)1:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§ 110.6(a)5:
Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets therequirements of 10-111 a .
§ 110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§ 110.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§ 110.8(i):
The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the
installation of a cool roof is specified on the CFI R.
§110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFIR.
§150.0(a):
Minimum R-30 insulation in wood -fame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§150.0(b):
Loose fill insulation shall conform with manufacturer's installed design labeled R -value.
§ 150.0(c):
Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U -
factor).
-§150.0(d): Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor.
§ 150.0(g)l: In Climate Zones 14 and 16 a Class 11 vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
walls, vented attics and unvented attics with air -permeable insulation.
§ 150.0(8)2: In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class I1
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of
§ 150.0(g)3: the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§ 150.0(1): Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration:
and when installed as part of a heated slab floor meets therequirements of § 110.8
§ 150.0(q): Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U -
factor of 0.58; or the weighted averse U -factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§150.0(e)IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e) I B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible operable, and tight -fitting damper or a combustion -air control device.
§ 150.0(e)IC: Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§ 150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building,are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§ 110.3(c)5: Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of § 110.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§ 110.5: antes without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
And spa heaters.
§ 150.0(h)1: Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
in §150.0(h)2.
§ 150.0(h)3A: Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
dryer vent.
§150.0(1): Heating systems are equipped with thermostats that meet the setback requirements of §I 10.2(c).
§150.06)IA: Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
with insulation having an installed thermal resistance of R-12 or geater.
§150.06)IB: Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external
insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system
§150.00)2A: regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A.
§ 150.06)2B: All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve
that allows for installation, removal, and replacement of the enclosed nine and insulation.
2013 Low -Rise Residential Mandatory Measures Summary
§ 150.06)2C:
Pipe for cooling system lines shall be insulated as specified in §I50.00)2A. Piping insulation for steam and hydronic heating
systems or hot waters stems with pressure > 15 psig shall meet therequirements in TABLE 120.3-A.
§ 150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§150.00)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
§150.00)3B:
or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
§150.0(n)l:
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§150.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of §I10.3(c)5.
§ 150.0(n)3:
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing enc approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§ 150.0(m)1:
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 18 IA, or UL 181 B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than %. inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross-sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§ 150.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§ 150.0(m)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling.
§150.0(m)7:
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers.
§ 150.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§ 150.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§150.0(m)10:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§150.0(m)11:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential A endix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§150.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
150.0(m) 12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
§150.0(m)13:
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
space conditioning system must also demonstrate airflow> 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
§150.0(m)15:
an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of>_ 350 CFM per ton of nominal cooling
capacity, and operating at an air -handling unit fan efficacy of <_ 0.58 W/CFM as confirmed by field verification and diagnostic
testing,in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§150.0(o):
central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
§150.0(o)IA:
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
§ 1 10.4(a):
Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
-
settin ; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
2013 Low -Rise Residential Mandatory Measures Summary
§ 110.4(b)l: Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and return lines or built-up connections for future solar heating.
§ 110.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§ 110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro -
ed to run only during off-peak electric demand periods.
§ 110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§ 150.0(p): Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§ 110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9.
§150.0(k)IA: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §150.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-B, as applicable.
§150.0(k)1B: When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with the applicable provisions of § 150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§ 150.0(k)] C: § I30.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting er electrical box.
§150.0(k)ID: Ballasts for fluorescent lamns rated 13 watts nr or rater shaft hP -A oU.,n U.,..e
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§ 150.0(k)IE:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to
be controlled by vacancy sensors.
§ 150.0(k)] F:
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of § 150.0(k).
§ 150.0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§ 150.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§ 150.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§ 150.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § I50.0(k).
§ 150.0(k)2F:
Lighting controls comply with applicable requirements of § 110.9.
An Energy Management Control System (EMCS) may be used to complywith dimmer requirements if it functions as a dimmer
§ 150.0(k)2G:
according to §110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other
requirements in §150.0(k)2.
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § 150.0(k) if: it
§ 150.0(k)2H:
functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements
of § 130.5; and all other requirements in &I50.0 2.
§ ] 50.0(k)2I:
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2.
§ 150.0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high effi racy.
§ 150.0(k)3B:
Kitchen fighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining
and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
§ 150.0(k)4:
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§ 150.0(k)5:
A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§ I50.0(k)6:
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§ 150.0(k)7:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy, or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§ 150.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § 150.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9.
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and
§ 150.0(k)9A:
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
2013 Low -Rise Residential Mandatory Measures Summary
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the
requirements for an EMCS in §130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§ 150.0(k)9B:
following requirements:
i. Shall comply with §150.0(k)9A; or
ii. Shall comply with the applicable requirements in 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0.
§ 150.0(k)9C:
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D
shall comply with the applicable requirements in § 110.9 130.0 § 130.2 § 130.4 § 140.7 and § 141.0.
§ 150.0(k)9D:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shal l comply
with the applicable requirements in § 110.9, § 130.0, § 13 0.2, § 130.4 § 140.7 and § 141.0.
§ 150.0(k)10:
Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined
according to § 130.0(c).
§ 150.0(k)11:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
nonresidential garages in § 110.9 130.0, § 130. 1, § 130.4, § 140.6, and § 141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§ 150.0(k) I2A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§ 150.0(k)12B:
i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of'
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§ 110.10(a)1:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014.
shall comply with the requirements of § 110.10 through 110.10 e .
§ 110.10(a)2:
Low-rise multi -family buildings shall comply with the requirements of § 110.10(b) through § 110.10(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§110.10(b)l:
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.
§ 110.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§ 110.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal ro;e on of the nearest point of the solar zone, measured in the vertical plane.
§ 110.10(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§ 110.10(c):
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system.
§ 110.10(d):
A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c)
shall be provided to the occupant.
§ 110.10(e)l:
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§ 110.10(e)2:
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and permanently marked as "For Future Solar Electric'.
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
SINGLE HOUSE
Date
8/3/2015
System Name
1ST FLOOR AREA
Floor Area
2,434
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems 1
COIL
CFM
Total Room Loads 1,018
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 6
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output perSystem 95,200
24,730
1,089 523
20,605
Total Output (Btuh) 95,200
0
Outside Air (%)
I
Output Btuh/s ft 39.1
965
976
-Cooling System
0
0
Output perSystem 57,000
0
0 0
0
Total Output Btuh 57,000
0
1,089
0
Total Output (Tons) 4.8
965
976
Total Output (Btuh/s ft) 23.4
Total Output s ft/Ton 512.41
26,660
22,557
Air System
ROOM
CFM per System
1,vtu
HVAC EQUIPMENT SELECTION
78/62°F 55/54°F
Airflow cfm
1,970
CARRIER 24ABB360/58CVA-155-22 (5 TON)
46,537 8,175
95,200
Airflow cfm/s ft
0.81
Outside Air
Airflow (cfm/ron)
414.7
0 cfm
Cooling Coil
Supply Fan
55 / 54 OF
Outside Air (%)
I
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
46,537 8,175
Aug 3 PM
95,200
Jan 1 AM
–0.0%
Outside Air cfm/ ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating
Peak
28 OF
68 OF 105 °F105 OF
i
Outside Air
0 cfm
Heating Coil Supply Fan
1,970 cfm
105 IF
ROOM
68 IF
68 OF
COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak)
88/68°F
78/62°F 55/54°F
55/54°F
Outside Air
0 cfm
Cooling Coil
Supply Fan
55 / 54 OF
1,970 cfm
41.0%ROOD
11� In
78 ! 62 OF
4
F—T 4
78 / 62 OF
EnergyPro 6.6 by EnergySofr User Number: 1919 RunCode• 2015-08-03T16.09.21 ID: R15-3933 Page 17 of 24
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
SINGLE HOUSE
Dale
8/3/2015
System Name
2ND FLOOR AREA
Floor Area
1,293
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems 1
COIL
CFM
Total Room Loads 369
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD 1
COOLING
PEAK COIL HTG.
PEAK
-Heating System
Sensible
Latent CFM
Sensible
Output per System 68,000
9,043
851 231
9,139
Total Output (Btuh) 68,000
0
433
Output Stuh/s ft 52.6
353
Cooling System
0
0
Output per System 33,400
0
0 0
0
Total Output Btuh 33,400
0
851
0
Total Output (Tons) 2.8
353
433
Total Output (Btuh/s ft) 25.8
Total Output s ft/Ton 464.6
9,749
10,005
Air System
CFM per System
i,,euu
HVAC EQUIPMENT SELECTION
Airflow (cfm)
1,200
CARRIER 24ABS336/58CVA-110-20 (3 TON) 27,505 4,556
'}✓��_
Outside AirAr
68,000
Airflow (cfm/s ft)
0.93
1,200 cfm
41.2%
ROOM
78 / 62 OF
Airflow (cfm/Ton)
431.1
Outside Air (%)
0.0%
Total Adjusted System Output 27,505 4,556 68,000
(Adjusted for Peak Design conditions)
Outside Air (cfm/s ft) 0.00
Note. values above given at ARI conditions ITIME OF SYSTEM PEAK I Aug 3 PM1 IJan 1 AM
HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak)
28 IF 68 OF 105 T 105 OF
Outside Air
0 cfm Heating Coil Supply Fan
1,200 cfm 105 IF
,,............... .,.-_............. . .
ROOM
68 °F
68 OF
COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak)
88/68°F 78/62°F 55!54°F 55/54T
..
POP A _—�—Lifl
'}✓��_
Outside AirAr
0 cfm AL Cooling Coil Supply Fan
55 / 54 IF
1,200 cfm
41.2%
ROOM
78 / 62 OF
781 62 °`r
�EnergyPro 6 6 by EnergySoft User Number 1919 RunCode: 2015-08-03716.09.21 /D R15-3933 Paqe 18 of 24
ROOM LOAD SUMMARY
Project Name Date
SINGLE HOUSE 8/3/2015
System Name Floor Area
1ST FLOOR AREA 2,434
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK I COIL HTG. PEAK
Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible
1STFLOORPLAN 1ST FLOOR PLAN 1 1,018 24,730 1,089 1,018 24,7301 1,0891 5231 20,605
PAGE TOTAL
TOTAL*
I ' Total includes ventilation load for
110,81
24,7301
1,0895231
20,605
F1,018
F 24,7301
1,089
F523 20, 605
i —c yy,-,u u uy cneigyoun userwumoer: 7a7a munE;we: 2075-08-03T16:09:21 ID R15-3933 Page 19 of 24
ROOM LOAD SUMMARY
Project Name
SINGLE HOUSE
Date
8/3/2015
System Name
2ND FLOOR AREA
Floor Area
1,293
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
Zone Name Room Name
Mult. CFM Sensible Latent
CFM
Sensible Latent
CFM Sensible
2ND FLOOR PLAN 2ND FLOOR PLAN
1 369 9,043 851
369
9,043
851
231 9,139
Total includes ventilation load for zonal systems.
EnergyPro6.6b Ener Soft User Number. 1919
PAGE TOTAL
TOTAL *
RunCode:2015-OR-03r1Br09.91
369 9,043 851
369 9,043 851
231 9,139
231 9,139
ROOM HEATING PEAK LOADS
Project Name
SINGLE HOUSE
ROOM INFORMATION DESIGN CONDITIONS
Room Name 1ST FLOOR PLAN Time of Peak
Floor Area 2,434.0 ft2 Outdoor Dry Bulb Temperature
Indoor Dry Bulb Temperature 68 OF
Conduction Area
R-38 Roof Attic 1,324.0 )
Double Metal Clear... 18.0 )
R-21 Wall 1,704.3 )
Double Non Metal Clear (6) 552.9
R-19 Floor W/Craw/space 2,434.0
11
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
X
X
X
X
X
X
X
X
Items shown with an --id, ` d
U -Value
AT °F
8/3/2015
Jan 1 AM
28 OF
Btu/hr
1,324
367
4,704
6,635
3,6021
s ( ) enote conduction through an interior surface to another room Page Total L 16,632
Infiltration:[ 1.00 x 1.077 x 2,434 x 9.00 x 0.253 /60] X 40 = 3,973
Schedule Air Sensible Area Ceiling Height ACH AT
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM 20,605
i -„C yyr.ru o.o oy cnergy,�ion user Number. 1919 RunCode 2015-08-03716 09 21 ID: R15 3933 Pape 21 of 24
ROOM HEATING PEAK LOADS
Project Name
SINGLE HOUSE
ROOM INFORMATION DESIGN CONDITIONS
Room Name 2ND FLOOR PLAN Time of Peak
Floor Area 1,293.0 ft2 Outdoor Dry Bulb Temperature
Indoor Dry Bulb Tem erature 68 OF
8/3/2015
Jan 1 AM
28 OF
LnergyPro 6.6 by EnergySoft User Number: 1919 RunCode: 2015-08-03716:09:21 ID: R15-3933 pan'. 99 nf 7d
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U -Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT OF
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
40
Btu/hr
R-38 Roof Attic
1,275.0
0.0250
40
1,275
Double Metal Clear..
18.0
0.5100
40
367
R-21 Wall
1,219.7
0.0690
40
31366
Double Non Metal Clear (6)
168.3
0.3000
40
2,020
*R-19 Floor W/O Crawlspace
1,092.0
0.0490
0
0
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.077
Schedule Air Sensible
Fraction
through an interior surface
X 1,293 X
Area
another room
9.00 X 0.253
Height ACH
Page Total
/60] X
AT
7,028
= 2,110
TOTAL HOURLY HEAT LOSS FOR ROOM 9,139
LnergyPro 6.6 by EnergySoft User Number: 1919 RunCode: 2015-08-03716:09:21 ID: R15-3933 pan'. 99 nf 7d
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
SINGLE HOUSE
8/3/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
1ST FLOOR PLAN
Outdoor Dry Bulb Temperature
88 OF
Floor Area
2,434.0 ft'
Outdoor Wet Bulb Temperature
68 OF
Indoor Dry Bulb Temperature 78 OF
Outdoor Daily Range:
30 OF
Opaque Surfaces
Orientation Area -U-Factor CLTD'
Btu/hr
R-38 Roof Attic
(N) 1,324.0 X 0.0250 X
37.0 =
1,225
R-21 Wall
(W 304.3 X 0.0690 X
13.0 =
273
R-21 Wall
(E) 406.2 X 0.0690 X
13.0 =
364
R-21 Wall
(N) 482.0 X 0.0690 X
3.0 =
100
R-21 Wall
(S) 511.8 X 0.0690 X
6.0 =
212
R-19 FloorW/Crawlspace
2,434.0 X 0.0370 X
4.0 =
360
X X
=
X X
=
X X
=
Page Total
2,534
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded Unshaded
Fenestration
Orientation Area GLF Area
GLF
Btu/hr
Skylight
(N) 0.0 X 10.3 + 18.0 X
46.9 =
844
WINDOWS
(W) 0.0 X 12.9 + 225.0 X
32.4 =
7,292
WINDOWS
(E) 0.0 X 12.9 + 141.4 X
32.4 =
4,583
WINDOWS
(N) 0.0 X 12.9 + 91.5 X
12.9 =
1,184
WINDOWS
(S) 0.0 X 12.9 + 95.0 X
17.8 =
1,688
X + X
=
X + X
=
X + X
=
X + X
=
Page Total
15,591
Internal Gain
Btu/hr
-Occupants
7.3 Occupants X 245 Btuh/occ.
=
1,789
Equipment
2,434 Floor Area X 0.50 w/g4 ft
=
4,154
Infiltration: 1.077
X 0.61 X 100.39 X 10 =
663
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
24,730
Latent Gain
Btu/hr
Occupants
73 Occupants X 155 Btuh/occ.
=
1,132
Infiltration:
X 0.61 X 100.39 X -0.00015 =
-43
Sensible
Air Sensible
CFM ELA Dye/
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
832
Ener Pro 6.6 by Ener Soft
User Number. 1919 RunCode: 2015-08-o3T16r09.91
1
IV
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
SINGLE HOUSE
8/3/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
2ND FLOOR PLAN
Outdoor Dry Bulb Temperature
88 °F
Floor Area
1, 293.0 ft'
Outdoor Wet Bulb Temperature
68 OF
Indoor Dry Bulb Temperature 78 OF
Outdoor Daily Range:
30 OF
Opaque Surfaces
Orientation Area U -Factor CLTD'
Btu/hr
R-38 RoofAttic
(N) 1,275.0 X 0.0250 X
37.0 =
1,179
R-21 Wall
(149 279.9 X 0.0690 X
13.0 =
251
R-21 Wall
(E) 292.4 X 0.0690 X
13.0 =
262
R-21 Wall
(N) 330.8 X 0.0690 X
3.0 =
68
R-21 Wall
(S) 316.6 X 0.0690 X
6.0 =
131
'R-19 Floor W/0 Crawlspace
1,092.0 X 0.0490 X
0.0 =
0'
X X
=
X X
=
X X
=
Page Total
1,892
Items shown with an asterisk (')
denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded Unshaded
Fenestration
Orientation Area GLF Area
GLF
Btu/hr
Skylight
(N) 0.0 X 10.3 + 18.0 X
46.9 =
844
WINDOWS
(W) 0.0 X 12.9 + 62.1 X
32.4 =
2,013
WINDOWS
(E) 0.0 X 12.9 + 49.6 X
32.4 =
1,608
WINDOWS
(N) 0.0 X 12.9 + 21.2 X
12.9 =
274
WINDOWS
(S) 0.0 X 12.9 + 35.4 X
17.8 =
629
X + X
=
X + X
=
X + X
=
X I + LX
=
Page Total
5,36
Internal Gain
Btu/hr
Occupants
3.9 Occupants X 255 Btuh/occ.=L
990
Equipment
1,293 Floor Area X 0.10 w/s4 ft
=
441
Infiltration:
X 0.61 X 53.33 X 10 =
352
Sensible
Air Sensible
CFM EtA AT
I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
Latent Gain Btu/hr
Occupants 3.9 Occupants X 225 Btuh/occ. = 874
Infiltration: 4,830 X 0.61 X 53.33 X -0.00015 = 23
Air Sensible CFM ELA AW
I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM r,
L EnergyPro 6.6 by EneMySoft User Number 1919 RunCode- 2015-08-03T16.09.21 ID R15-3933_ Paae 24 of 24