Loading...
B-2016-1471 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO:B-2016-1471 21155 LAURETTA DR CUPERTINO,CA 95014-1662(326 55 016) DAYANENI BHOGES WARA R AND SUVARNA L TRUSTEE OWNER'S NAME: DAYANENI BHOGESWARA R AND SUVARNA L TRUSTEE DATE ISSUED:03/04/2016 OWNER'S PHONE:408-368-9366 PHONE NO: LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO: License Class Lic.# Contractor DAYANENI BHOGESWARA R AND SUVARNA L TRUSTEE Date X BLDG X ELECT X PLUMB I hereby affirm that I am licensed under the provisions of Chapter 9(commencing MECH X RESIDENTIAL COMMERCIAL with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. JOB DESCRIPTION: INSTALL(N) 16 ROOFTOP SOLAR PANELS(4.48 KW); UPGRADE I hereby affirm under penalty of perjury one of the following two declarations: MAIN PANEL TO 200 AMP;REPLACE WATER HEATER IN GARAGE. 1. I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. 2. I have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:S 17000.00 APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county APN Number: Occupancy Type: ordinances and state laws relating to building construction,and hereby 326 55 016 authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save indemnify and keep harmless the City of Cupertino against liabilities,judgments,costs, and PERMIT EXPIRES IF WORK IS NOT STARTED expenses which may accrue against said City in consequence of the WITHIN 180 DAYS OF PERMIT ISSUANCE OR granting of this permit. Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal 180 DAYS FROM LAST CALLED INSPECTION. Code,Section 9.18. Issued by:_+1"4f Signature Date Date: OWNER-BUILDER DECLARATION RE-ROOFS: I hereby affirm that I am exempt from the Contractor's License Law for one of the All roofs shall be inspected prior to any roofing material being installed.If a roof is owkng two reasons: installed without first obtaining an inspection,I agree to remove all new materials for XT 1. I,as owner of the property,or my employees with wages as their sole inspection. compensation,will do the work,and the structure is not intended or offered for sale(Sec.7044,Business&Professions Code) Signature of Applicant: 2. I,as owner of the property,am exclusively contracting with licensed Date: contractors to construct the project(Sec.7044,Business&Professions Code). I hereby affirm under penalty of perjury one of the following three declarations: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER 1. I have and will maintain a Certificate of Consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the HAZARDOUS MATERIALS DISCLOSURE performance of the work for which this permit is issued. I have read the hazardous materials requirements under Chapter 6.95 of the 2. I have and will maintain Worker's Compensation Insurance,as provided for California Health&Safety Code,Sections 25505,25533,and 25534. 1 will by Section 3700 of the Labor Code,for the performance of the work for which maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the this permit is issued. Health&Safety Code,Section 25532(a)should I store or handle hazardous I certify that in the performance of the work for which this permit is issued,I am material. Additionally,should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I shall not employ any person in any manner so as to become subject to the will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and Worker's Compensation laws of California. If,after making this certificate of the,Health&Safety Code Sections 25 533,and 25534. exemption,I become subject to the Worker's Compensation provisions of the Labor Code,I must forthwith comply with such provisions or this permit shall Owner or authori ed agentll . be deemed revoked. Date: � �6 h (� APPLICANT CERTIFICATION -[ CONSTRUCTION LENDING AGENCY I certify that I have read this application and state that the above information is I hereby affirm that there is a construction lending agency for the performance correct. I agree to comply with all city and county ordinances and state laws of work's for which this permit is issued(Sec. 3097,Civ C.) relating to building construction,and hereby authorize representatives of this city Lender's Name to enter upon the above mentioned property for inspection purposes. (We)agree to save indemnify and keep harmless the City of Cupertino against liabilities, Lender's Address judgments,costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally,the applicant ARCHITECT'S DECLARATION understands and will comply with all non-point source regulations per the I understand my plans shall be used as public records. Cupertino Municipal Code,Section 9.18. Licensed Professional ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION 10300 TORRE AVENUE• CUPERTINO, CA 98014-3285 (408)777-3228 - FAX(408)777-3333 • buildinp(a,cugetno.orq CUPERTlh10 PROJECT ADDRESS 2 ! S 5 LAQ deJ2—'tr P% '1�f• I APN R OWNER NAD4E PHO1"sa&9� O Ga� I pE- v�Y7�C-�i STREET ADDRESS t�SS r rA U CITY, STATE,ZIP l 77 j ��,C Ac�� r FAX CONTACT NAME �� y n`'� 1��S PHONE u P to I T4.AILCb •��� STREET ADDRESS I CITY,STATE, ZIP FAX X OWXTTER OWNER-BULUER ❑ OR'NEER AGENT ❑ CONTRACTOR ❑CONTRACTOR AGED-I' ❑ ARC'=CT ❑ENGATEER ❑ DEVELOPER ❑ TENp.NT CONTRACTOR NAME LICENSE NU1\4BER LICENSE TYPE I BUS.LIC COMPANY NAME I E-MAIL I FAX STREET ADDRESS I CITY,STATE,ZIP PHONE ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS.LIC 2 COMPANY NAME E-MAIL FAX STREET ADDRESS I CITY,STATE,ZIP PHONE USE OF JVD or Duplex ❑ Multi-Family PROJECT IN WILDLAND PROJECT IN STRUCTURE: ❑ Commercial URBAN INTERFACE AREA ❑ Yes _Delo FLOOD ZONE ❑ Yesft-NO SOLAR PANELS ❑ ELECTRIC VEHICLE CRARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER: FOR SOLAR FAKELS. NU1\4BER OF PANELS/UN T : KILOWATTS(COMMERCLAL ONLY): 7TOTAL VAL ATIO : Q v� 00,0 0 DESCRIPTION OF WORK �� .. o pi i Sofa ® t-' W. zo SeY 11' 'f"o �_00 By my signature below,I certif�y to each of the following: I am the property oNvner or authorized agent to act on the property A 's alf. I have read this application and the information I have provided is correct. I have read the Description of Work and verit,it is accurate. I agree to comply with all applicable local ordinances and state laws relatingding constructs . thorize representatives of Cupertino.to enter the above-identified property for inspection purposes. S ignature of Applicant/Agent: Date: O /an SUPPLEMENITAL 1NTFORMATIOINr REQ UZRED =---_ - OFFICEbSED�LY= s '=$: := -�._. ='::-,r—�:r:_-..-., tiz�-jar=:•- r:___.�_en..nt J: ( _ a �,cTAi�DARD > I z Jr f;-� rZ, •-ct _�{�`Lx'1RGL F1,'4pp_2011.docrevised 03/16/11 i >_ OWNER-BUILDER DISCLOSURE FORM COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION 10300 TORRE AVENUE• CUPERTINO, CA 95014-3255 (408)777-3228 - FAX(408)777-3333 • buildino(5cupertino.org — CUPERTIhtO- Dear Property Owner(s): An application for a building permit has been submitted in your name listing yourself as the builder of the property improvements specified at: - SITE ADDRESS APN... SPS OWNER NANIE .; .OWNER ADDRESS- DESCRIPTION OF WORK: " ' G We are providing you with an Ownet-Builder Acknowledgment and Information Verification Form to make you aware of your responsibilities and possible risk you may incur by having this permit issued in your name as the Owner-Builder. We will not issue a building permit_until you have read, initialed your understanding of each provision, signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice unless you, the property owner, obtain the prior approval of the permitting authority. OWNERS ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION (DIRECTIONS:Please read and initial each statement below to signify you understand or verify this information.) Jul. l understand a frequent practice of unlicensed persons is to have the property owner obtain an"Owner- Builer" building permit that erroneously implies that the property owner is providing his or her own labor and material pers nally. I, as an Owner-Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person and his or her employees while working on my property. My homeowner's insurance may not prove coverage for those injuries. I am willfully acting as an Owner-Builder and am aware of the limits of my J11 surance coverage for injuries to workers on my property. lt9". I understand building permits are not required to be signed by property owners unless they are responsible for the c' nstruction and are not hiring a licensed Contractor to assume this responsibility. n AMI understand as an Owner-Builder I am the responsible party of record on the permit. I understand that I may myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her nstead of my own. I understand Contractors are required by law to be licensed and bonded in California and to list their license s on permits and contracts. understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value of my construction is at least five hundred dollars ($500), including labor and materials, I may be 4fe sidered an "employer" under state and federal law. I understand if I am considered an "employer" under state and federal law, I must register with the state and erall government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unem,loyment compensation for each "employee." I also understand my failure to abide by these laws may subject e to serious financial risk. 1 . 1 understand under California Contractors' State License Law, an Owner-Builder who builds single-family residential structures cannot legally build them with the intent to offer them for sale, unless all work is performed by Iicen fed subcontractors and the number of structures does not exceed four within any calendar year, or all of the work pe ormed under contract with a licensed general building Contractor. 8. I understand as an Owner-Builder if I sell the property for which this permit is issued, I may be held liable for any financial or personal injuries sustained by any subsequent owner(s) that result from any latent construction defects in the workmanship or materials. OwnerBuilderForrn 2010.doc revised 0:'/14/10 v 'tai9. I understand I may obtain more information regarding my obligations as an"employer" from the Internal Revegue Service, the United States Small Business Administration, the California Department of Benefit Payments, and to California Division of Industrial Accidents. I also understand I may contact the California Contractors' State Licer e Board (CSLB) at 1-800-321-CSLB (2752) or www.cslb.ca.gov for more information about licensed cont actors. J 10. 1 am aware of and consent to an Owner-Builder building permit applied for in my name, and understand that I am the party legally and financially responsible for proposed construction activity at the site address listed above. r` 1. 1 agree that, as the party legally and financially responsible for this proposed construction activity, I will abide by al applicable laws and requirements that govern Owner-Builders as well as employers. 2. 1 agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the infor�►ation-l-have-provided on this form. Licensed contractors are regulated by-laws designed to protect.the..public. If you contract with someone who does not have a license, the Contractors' State License Board may be unable to assist you with any financial-loss you may sustain as a.result of a complaint-Your only remedy against unlicensed Contractors maybe in-civil court. If is also important for you-to understand that if an unlicensed Contractor or employee of that individual or firm is injured.while working on your property, you may be held liable for damages. If you obtain a permit.as Owner-Builder and wish to hire Contractors, you will be responsible for verifying whether or not-- those otethose Contractors are properly licensed and the status of their workers' compensation insurance coverage. CONSTRUCTION LENDING AGENCY (DIRECTIONS:Please complete the following construction lending agency information.) I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097 Civ.) Lender Name: Lender Address: Before a building permit can be issued,this form must be completed and signed by the property owner and returned to the agency responsible for issuing the permit. Note:A copy of the property owner's driver's license, form notarization, or other verification acceptable to the city may be required to be presented when the permit is issued to verify the property owner's si natur . Property Owners Signature: Date: 0 5 10 tk, --------------------------------------------------------------------------------------------------------------------------------------------- (NOTE: The follov✓Ing Authorization Form is required to be completed by the property own only when designating an agent of the property owner to apply for a construction permit for the Owner-Builder). AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize the following person(s) to act as my agent(s)to apply for, sign, and file the documents necessary to obtain an Owner-Builder Permit for my project. Scope of Construction Project(or Description of Work): Project Location or Address: Name of Authorized Agent: Tel No Address of Authorized Agent: I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above information and certify its accuracy. Note:A copy of the property owner's driver's license, form notarization, or other verification acceptable to the city may be required to be presented when the permit is issued to verify the property owner's signature. Property Owner's Signature: Date: CrvnerBuilderForm 2010.doc revised 04,114110 4.48 KW DC PV SYSTEM SOLAR ROOF PROJECT REVISION ED 21155 Lauretta Drive, DATE NO IV Cupertino, CA 95014 03/03/2016 T l� ^�i SOLAR PANELS:SUNIVA OPT 280-60-4-100 STC:280 W DC, D TOTAL 16*280W=4.48 KW DC (STC) SHEET INDES: ® A-1 GENERAL NOTES,SHEET INDEX,BUILDING DATA, CUPERTINO PROJECT DATA,SITE PLAN BuIldIng Department A-2 PV LAYOUT PLAN E-1 SINGLE LINE DIAGRAM O O EL ,. , E-2 WARNING NOTES .`::� MAR 0 4 2016 E-3 EQUIPMENTS:PV MODULE SPECIFICATION SHEET ° E-4 EQUIPMENTS:INVERTER SPECIFICATION ° O REVIEWED FOR CODE COMPLIANCE S-1 EQUIPMENTS:ROOF STRUCTURE S-2 EQUIPMENTS:RACK SPECIFICATION 1' °ffffl • &INSTALLTION-IRONRIDGE RAIL SYSTEM S-3 EQUIPMENTS:RACK SPECIFICATIONR i ` rLvH KED BY ng., w r ���• �I Mml vivlvi 44-JV ° &INSTALLTION-IRONRIDGE RAIL INTERGRATED E'4.. GROUNDING ` DATE -- W PLANNING DEPT c c CUPERTINO COMMUNITY DEVELOPMENT DEPARTMENT CODE AUTHORITY: BUILDING DIVISION-CUPERTINO 2013 CALIFORNIA BUILDING STANDARDS PAR0q p771) ADMINISTRATIVE CODE 2013 CALIFORNIA BUILDING CODE nl,fir e2013 CALIFORNIA ELECTRICAL CODE 2013 CALIFORNIA MECHANICAL CODE =:, .,. 3;t"Ie, ^i` !L'.•" 2013 CALIFORNIA PLUMBING CODE !Ei 10ut tr' it tyUiidin %}f it;!� 2013 CALIFORNIA FIRE CODE T ? ir, t•. r ; SHALL N(\)T RECEIVED 'd`:U Permit or to tie an cpproval of the violation o`,an r N'sio City Ordinance or State Law, — LAURETTA DRIVE ��`AP, 0 4. BY B D,=,TE �' B AIVA TECHNOLOGY PERMIT NO. —201"6 BY 792 Barber Lane,Milpitas,CA 95035 www.aivatechnology.com,Phone:408 314 9589 PHOTOVOLTATIC NOTES: 1.AN INVERTER OR AN AC MODULE IN AN INTERACTIVE PHOTOVOLTAIC SYSTEM SHALL AUTOMATICALL DE-ENERGIZE ITS OUTPUT TO THE CONNECTED VICINITY PLAN PROMM ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THAT SYSTEM AND SHALL REMAIN IN THAT STATE UNTIL THE ELECTRICAL SCALE:NTS 4.48KW PV SYSTEM PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED.(NEC 69036 1) SOLAR ROOF PROJECT 2.ALL EXTERIOR ELECTRICAL METALLIC TUBING(EMT)CONDUIT FITTING SHALL BE RAINTIGHT THREADLESS COMPRESSION TYPE. 3.MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED 4.NAMEPLATES SHALL BE PROVIDED FOR ALL CIRCUITS IN THE SERVICE DISTRIBUTION AND POWER DISTRIBUTION SWITCH BOARDS,PANEL BOARDS, DISCONNECTING SWITCHES,TERMINAL CABINETS,ETC.ALL NAMEPLATES SHALL BE PERMANENTLY ATTACHED AND BE OF SUFFICIENT CAPACITY TO WITHSTAND Rao Da aneni THE WEATHER. Y 5.JUNCTION BOX/COMBINER BOX HAVE TO USE COMPRESSION TYPE STRAIN RELIEF POSITIONED FOR APPROPRIATE WATER RUN OFF. 21155 Lauretta Drive,Cupertino,CA 9501 6.CONDUIT RUNS SHALL BE PROVIDED WITH SUFFICIENT WEATHERPROOF PULL BOXES OF JUNCTION BOX/COMBINER BOXES PER APPROPRIATE NEC REQUIREMENTS. 7.SEE PROVIDED CUT SHEETS FOR ADDITIONAL EQUIPMENT SPECIFICATIONS 21155LauretlaDr DRAWING: 8.WIRING MATERIALS SHALL BE SUITABLE FOR THE SUN EXPOSURE AND WET LOCATIONS.FIELD APPLIED PROTECTIVE COATINGS ARE NOT ACCEPTABLE. A 9.JUNCTION,PULL AND OUTLET BOXES LOCATED BEHIND MODULES SHALL BE SO INSTALLED THAT THE WIRING CONTAINED IN THEM CAN BE RENDERED A GENERAL NOTES,SHEET INDEX, ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF MODULE(S)SECURED BY REMOVABLE FASTENERS AND CONNECTED BY A FLEXIBLE.WIRING SYSTEM.(NEC 690.34) BUILDING DATA,PROJECT DATA, 10.IN AN UNDERGROUND PHOTOVOLTAIC SYSTEM,THE POWER SOURCE SHALL BE LABELED WITH THE FOLLOWNIG WARNING AT EACH JUNCTION BOX,COMBINER SITE PLAN BOX,DISCONNECT AND DEVICE WHERE THE UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE:"WARNING-ELECTRIC SHOCK HAZARD.THE CURRENT CIRCUIT CONDUCTORS OF THIS PHOTOVOLTAIC POWER SYSTEM ARE UNGROUNDED BUT MAY BE ENERGIZED WITH THE RESPECT TO GROUND DUE TO LEAKAGE PATHS AND/OR GROUND FAULTS."(NECE 690.35(F)) 11.ALL PHOTOVOLTAIC MODULES AND ASSOCIATED EQUIPMENT AND WIRING MATERIAL SHALL BE PROTECTED FROM SREEr: ANY PHYSICAL DAMAGE. 12.ALL ELECTRICAL DEVICES AND UTILIZATION EQUIPMENT SHALL BE LISTED BY AN APPROVED TESTING AGENCY. A-1 13.ALL WORK TO COMPLY WITH THE LASTEST EDITION OF CALIFORNIA ELECTRICAL CODE AS AMENDED AND Laueetta Dr ADOPTED BY THE CITY OF EASTVALE.2013 C.E.C. I J Y REVISION DATE NO 03/ 03/2016 D 0 43'-0" 0 SKYLIGHT O 0 C I 4'-0" 6' O —0" 11 6'-019 "6'— 4'-0' , Ai tv v v- vvv I o JUNCTION BOX O B B AIVA TECHNOLOGY 792 Barber Lane,Milpitas,CA 95035 www.aivatechnology.com,Phone:408 314 9589 1/2"EMT CONDUIT PROJECT: 4.48KW PV SYSTEM SOLAREDGE SOLAR ROOF PROJECT SE5000A-US INVERTER WITH INTERGRATED DC DISCONNECT C Rao Dayaneni AC DISCONNECT VICINITY PLAN 21155 Lauretta Drive,Cupertino,CA 9501 MAIN SERVICE PANEL N SCALE: 3/16"=1'-0" C AND PG&E METER ROOF TYPE CURVED TILE DRAWING: - A STRUCTURAL CALCULATION A PV LAYOUT PLAN TOTAL PV SYSTEM WEIGHT 1002 LBS ARRAY SQUARE AREA 308 SOFT TOTAL PV SYSTEM WEIGHT ARRAY DEAD LOAD= ARRAY SQUARE AREA 325 LBS/SF sHEEr: TOTAL PV SYSTEM WEIGHT ARRAY POINT LOAD= 35.78 LBS A-2 REVISION DATE NO 03/03/2016 ` D 314'EMT CONDUIT 12'EMT CONDUIT (3)10 AWG THWN-2 SUNIVA OPT 28HO4-100 SOLAR PANELS:16 PIECES (1)10AWG GROUND W RE SOLAREDGE OPTIMIZERP300:16PIECES (2) 110AWGTHW-2 10 AWG TEMPERATREDE-ROA (t)i310AWGTHWN-2GROUNO TEMPERATURE OE-RATING@104F=0.91 10 AWG RATE 90'C=40A MAX CURRENT=2IAX 125%=26.25A TEMPERATURE DE-RATING@104 40A.091=36.4>2625A 7+307=071 OK TO INSTALL 10 AWG THWN-2 AMP=I5AX 125%X 125%=23.44A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 18 40A x 0.71=28A*3.44A (D C OK TO INSTALL 10 AWG THWN-2 SP,100A L IR�USE C INVERTER:SOLAREDGE SE500DA-US JUNCPON BOX 30A FUSED AC DISCONNECT E� fN DC OUTPUT Lz m BARE CAPPER BAWD INVERTER (2)(a`10AWG USE-2 INTEGRATED DC DISCDISCONNECTw,AcoswxxEcr 10 AWG RATE 9010-00A TEMPERATURE DE-RATING@104 AMP=I5AX 125%X 125%=23.44A UPGRADE T0200A RATING SERVICE PANEL 40A x 0.718.4>23.44A 2P,30A BREAKER FOR SOLAR OK TO INSTALL 10 AWG USE-2 B 01 SOLARPANELANDSOIAREDGEOPTIMIZER B AIVA TECHNOLOGY SUNIVA OPT 280DC 4OINVERTER RATING 792 Barber Lane,Milpitas,CA 95035 STC 280W SOLUS www.alvatechnology.com,Phone:408 314 9589 ELECTRICAL DATA PER PANEL @NOCT: MAX.DC INP T VOL A GE Voc =38.70V MAX.DC INPUT VOLTAGE =500V AMAIN PANEL RATING ®OUTPUT CALCULATION Vmp =31.70V MAX.INPUT POWER(STC) =6750W MPPTRANGE =125V-500V ISc =9.30A MAIN PANEL BUS BAR RATING=200A PV SYSTEM MAX DC OUTPUT: 28OW x 16=4.48kw MAX.INPUT DC CURRENT =15.5A Imp =8.64A MAX.OUTPUT APPARENT POWER =5450VA MAIN BREAKER =200A PV SYSTEM MAX AC CALCULATION USING PTC PMAX: TPUT CURRENT =21A SOLAR BREAKER =30A PMAX PER MODULE=254.99W PROJECT: MAX.. SOLAREDGE OPTIMIZER P300: SUPPLY POWER=200A x 1.2-200A=40A>30A, 254.99W x 16=4.08KW 4.48KW PV SYSTEM =240V 1211V-264V MAXIMUM OUTPUT CURRENT=15.00A NOMINAL VOLTAGE/RANGE OK 4.08KWx 98%=3.998KW MAXIMUM OUTPUTVOLTAGE =85V NOMINAL FREQUENCYIRANGE =60Hz159.3Hz-60.5Hz SOLAR ROOF PROJECT CEC EFFICIENCY =98% Rao Dayaneni 21155 Laurette Drive,Cupertino,CA 9501 DRAWING: - A SINGLE LINE DIAGRAM SHEET: E-1 REVISION DATE NO 03/03/2016 D WARNING ELECTRIC SHOCK e DO NOT TOUCH TERMNALS WARNING THIS ELECTRIC SERVICE IS TERMINALS ONBOTH .i i INVERTEROUTMCONNECTION. ALSO SEILVEDBY rt aro.. o 0 o e ,'e ee NOT RELOCATETHIS i 3 1 e1 W We PHOTOVOLTAIC OVERCURRENTI)EVICE n REQ'D BY: NEC 690.17 REQ'D BY:AHJ ,1 REQ'D BY: NEC 690.56 (B) } REQ'D BY: NEC 705.12 (D) {4) L� 2 REQ'D BY: NEC 705.12 (D) (7) l`*J 5 APPLY TO: APPLY TO: o APPLY TO: APPLY TO: DISCONNECTS SOLAR CONDUIT APPLY TO: DC DISCONNECTS MAIN SERVICE PANEL PV LOAD CENTERS PV SYSTEM BREAKER COMBINER BOXES I , e12ROTIOE ; leo -DISCO ®,m o -RATED WC OVZUWN e, d,YLI e , e @ e 'e' �' @ e' e n REQ'D BY:AHJ �7Q'D BY: CRC R331.7 n REQ'D BY: NEC 690.54 o r APPLY TO: APPLY TO: APPLY TO: DISCONNECTS MAIN SERVICE MAIN SERVICE INTERACTIVE PV LOAD CENTERS DISCONNECT POINTS OF COMBINER BOXES INTERCONNECTION B AIVA TECHNOLOGY 792 Barber Lane,Milpitas,CA 95035 www.aivatechnology.com,Phone:408 314 9589 PROJECT: NOTES: 4.48 KW PV SYSTEM 1 . The marking shall be placed adjacent to the main service disconnect clearly visible from the locatin where the lever is operated. SOLAR PROJECT 2. Markings format: White letter on a red background, Minimun 3/8 inches letter height, All letters shall be capitalized, Arial or similar PPMEM : font, non-bold. Rao Dayaneni 3. Material: Reflective, weather resistant material suitable for the environment. Use UL969 as standard for weather rating. Durable 21155 Lauretta Drive,Cupertino,CA 95014 adhesive materials meet this requirements. 4. Markings shall be placed every 10 feet on all interior and exterior DC conduits, raceways, enclosures, and cable assemblies, at turns A DRAWING: above and/or below penetrations, all DC combiners, and junction boxes. LABELS AND WARNING 5. A warning label shall appear on the utility-ineractive inverter or be applied by the installer near the ground-fault indicator at visible NOTES location. SHEET: E-2 REVISION DATE NO 03/03 /2016 D OPTIMIUS SERIES: OPT 60 CELL MODULES I. jyl I 1.iI {I T•I�_.',lI. ELECTRICALDATA(NOMINAL)iy eat=Model.Number UPT OPT OPT OPT nrhrr-r«c(ri�al pa•an;:•;�•;n•- .., '� 'I •nae•ua,u o'Saiarahaat:,n,6.a` 1 .1265-6D-44013 1tit 1 1 4 t 1, Poem Classification(Pmnx) 26S W 1270 W 275 W j 280 W ' S I PTI S�SERIES _ 2 Nodose Efficiency(°��) � i6.33°a i,i.60°� � Iti.)S°:, !17_h% { I I I — ( R I NE SOLAR MODULESf Voltage at Max.Power Point(Vni ) 307 70 V --- a l-tl V j 31.50\' J j 31.70 VMONOCRYSTI i j l @L�! — — — - I I - - -.- -- _-.- ,--. � ' Curren;al D•tax.Pnu-rr Point(Imp) I 9.64 A 8.68 A 8.:4 n 8.54 A S Ili . tli O en Circuit Vnlla f•e-(Voc)----- i 38.30 V,----- 38 50 V— --�38,60 V -38.70 V O i l PTSERIES:OPT60CELLM0DULES(SI LVE.R.;FRAME)`� shortt.ircuuCurrrnl(ls)---- I4izA- - st -- ------' - --� P ' I 9'_4 i ec!! Optimus©modules are known for their superior quality { , f �r_o.r�at d<:;ao;,ro tan 1c,a �,:�,r� aJ+a,N or+..cv .,. 4,,,+,41V, �z+3 a1 a°c. ^' and loin-teras reliability. These high-powered modules CHARACTERISTIC DATA consist of Suniva's premium ARTisune Select cell technology - --- -- -, ENGINEERING EXCELLENCE Type of Solar Cell Hig,-ef€ieiencyARTisunSelect cells ufl56x156runt(6in.) C and are designed and manufactured in the U.S.A.using our a - - C ■ Built exclusively with Sunivas premium ARTlsunpioneering ion implantation technology. Suni\a's high 1 Fr..n,e �i!ve;anodized alun,:nnm alloy Select calls,providing one of the highest power power-density t)ptimus nodules provide excellent ,•( _irrl' Glass T --- - -- Trmpered(lowiron)anti-reflective coanng --- outputs per square meter at an affordable price a- •a t I performance and value. A junction Pox-- _NEMA iP67 rated me nal bypitss diodes I FEATURES - T a 'Suniva is a U.S.based company spun our from the. pGi S g�\ cable&cvnnxct'ors12 A1VG(4 mn,r)'PV Wire(stile with multiple connector options Georgia Tech University Center of Extellanca'in zr (�� xv, Z 4 2' -------- _— available;cable length 1000 i„m — — Contains premium ARTisun Select cell PhO,tdvoltaics:one of only two such research centers (�;T'�•-'�:' n the U.S. technology -over I9% e �(}S MECHANICALS ■ Suniva's state-Of-the arrmanufacturing and Modula t ;. Extensive materials testing and Cells t Module {0(6 x 10) t- la6 fatilifies feature the(nest advanced equipment al j ----- — ---- - -- ----- - certifications safeguard reliability and technology Module Dimensions 1652x 982 mm f65.04 x 38.66 in) I. i ;• Positive on1w tolerance ensures •� 1.57 . 11,1odulcThicknessDlpth) 40nuu( u,QUALITY & RELIABILITY predictable output :l ti' . 0.25 k& r-O.Slb-) ------ ■ Suniva Optimus modules are manufactured and .warranted to our specifications assuring consistent * AZarine gTade aluminum frame with hard encs.«.«,e„ �-v=wa t 7 ae+rse•n m�..ia� high performance and high quality. TEMPERATURE COEFFICIENTS anodized coating; ------...------___--- —_--- _ � --------------------- ----- n :Rigorous in-house quality management tests I_.-i_ _. j.._.. i _. - Voltage G,Vee(,dr"i:) -0.335 beyond standard UL and IEC standards ; I3uv America-corn.pgiant upon request I Current kcn, .(%/'c) r0 „.o1 s B ■ Perfo;mance lcngevity with advanced z- I .- T l._... �i P—r ----- --- LY,Pma_Y(%I,C) --- ------ -0.320 a AIVA TECHNOLOGY �,r Qualifies for U.S.ElINI financing - --- - ---- - - - - --- polymer backsheet I - NOCT Avg I+1.2"C) t c 792 Barber Lane,Milpitas,CA 95035 www.aivatechnologymom,Phone:408 314 9589 ■ Passed the most stringent salt spray tests based a,. System and designs services available ° _ «• A®a Iq on IEC 61701 -� tee,. ti �«.:ap• LIMITS Industryleadits'lunevyrWarralnty:l0 ear © Passed enhanced stress tests'based on IEC 61215 ' Max.System Valtage 1000 VDC for tEC,1000 VDC for U1 conduczed at Fraunhofer ISE - ----- ----J--_-.-_.__------ ------ --- -' warranty on workmanship and materials; Max Senes Fuse Rad ng 15,A nip-, i ® 25 Year linear performance warranty ,oa9< ts�'Ni — ----- - - --- -- - - Certified,Plb free by PV Evolution Labs'(PVEL) Y/y I` Operating 141adu]eTem, ,tore ' 9r 35., -_.Fqk q S } g 1 • -40'C to rs C(-10"f to r 185'F) PROJWT: delivering SO�o power at STC w �.•pr^ �Mp ■ PAN files are Independently validated STS Storm Resisrnnce;Static Load 1'roed to!EC 61215 for load*of 5400 Pa(I 13 psi); � 4.48KW PV SYSTEM CERTIFICATIONS 90%. q�C ��q�r i',etland wind resistant SOLAR ROOF PROJECT P Ila R,p�ryNG Sun' r-�✓',�« z r, 'ant i ,anr a Je ria ar-: .erne teu,rranu t urr s,t•r r i { a Ty 'Lt S✓{INr c a0n v4 26,00 ... .,o. _ r �u _ / R a- -�., y° kRDYRtd;kt'G9]UR r-IE 3-^r'tJ.,.. t.... ;il�r.),? :r�� ".,"^', '+r_t i 0 1 12 25 HEADQUARTERS Rao Dayaneni _ W2511 a,n1 sa ,re-ronstra rvu _.._- =' 21155 Laurette Drive,Cupertino,CA 9501 T-60 s I0611700rrol ansa 1404 4l300+S?US.4, [;PLEASE RECYCLE oP c t tgt+1 a044772iCO (s_ t ). ria..EtiAVbU5T P,2314(REV.21) SM, O 04107 Isilyer-and dlacFJ i I . •` '•` - www.suniva.cotn h:5nit,a,,.e ci Soi�.iva � DRAWING: _ A EQUIPMENTS:PV MODULE SPECIFICATION SHEET SHFFM E-3 REVISION DATE NO 03/03/2016 rs Power Optimizer SPeci/icotions-P30DI P400D solar- .• Power Optimizer Specifications- P300 / P400 solar=@ " Single Phase Inverters for North America SE300DA-US J SE3000A-US/SE50DOA-US/SE60DOA-US/ IPsoo eaoli: SE76DOA-US/SE1000GA-US/SE1140OA-US INP Ur' Rated Input DC Power") 300 W S 300DA-US SE38COA-US?SE5000A-US 5 SOODA-US SE760OA-US j SE ODOOA-US SE1140OA-US -- --_.-------- ----�-----�- -�-- -�- �.-------- Absolute Maximum Input Voltage(Voc) 48 80 N,, Vdc OUTPUT 998 @ 2g8V MDPT Operating Range 8-48 8-80 Vdc Nominal AC Power Output \C. 3800 5000 000 7600 ! 100. @24DV 11400 VA ... .. ._ .. l .. .... .. .. .UU . .. .. Maximum Short Circuit Current(Isc)of connected PV Module 10 Adc 5400 @ 70EV 10800 209V Max.AC Power Output 4150 6 00 8350 1 12000 VA ro 5450 @240V 10950 Z40V Maximum DC Input Current 12.5 .... ... .. .. .. I .. .... .. ..... aAC Output Voltage Mbl.-Nom:Maxl" I Maximum Efficiency 99.5 % 183-208-229Vac - - Weighted Efficiency 98.8 AC Output Voltage Min.-Nom.-Max.01211-2a0-264 VacJOvervoltage Category 11 . ....... ._........ .. .. . ... ...... .... ........... ...! ....... ..... ... ..... . ...... .ACFrequencyMln.-Nom.Max,' 593 60-60.5(with HI count setting 57-60 60.5( Hz24 @ 2g8V 48 @ 2g8VMax.Continuous Output Current 16 1 25 32 47.5 A Maximum Output Current 15 Adc � @240YGFDIThreshoId 1 A Maximum Output voltage 60 Vdc UtilityMDnf[ming,IslandingProlectian,Cotable Thresholds Yes Yes 'OUTPUTDURRVC SjANDBY"(POWE ;OPTIMIZER-DISCONNECTED FRONIINVER,TER OR,INVERTER=0FF1 `- --- INPUT ower OptlmlZer 1 Vdc C Maximum DCPower(STC) 4650 5100 675Q 8100 10250 13500 15350 W C I i Output Voltage per P Safely Transformer-less,Ungrounded Yes STANDARD COMPL1AtdCE - . ....... ........ .. .. .. ... .. .. ... . ... .... .. .. .. .. .. - Max.Input Voltage 500 _ Vdc 0-6-2 IE .... .... ..... .. ... -.. .. .. .. .. - .... .. .. .. .. .. .. Nom.DC Input Voltage 325 @ 2D8V/350 @ 2401 Vdc ..... ....... .... -. ..... .. .. .. ............ .... ... ... ... ... I , ... .. . 21 - ( s5 II s L1741 1 EMC - � FCC Pari15 Class 8 IEC6100 C610D0-5-3 I5.5 @ 2g8V f33 @ X061 May.Input Current' 9:5 1 I t „18 ...i 2 3........40V.� 4.5 Adc - @ 240V _ 0.5 @ 2 Material E UL-941(5-VA),UV Re istant Max:Input Short Grcuft Gtrrent i 45 Adc .. ........ .. .... .. .... .. ... .. .. .... ... .. ,. ...... .. .. .... .. .. .. .. .. .. ... .. ,. Yas 0 Reverse-Polarity Protection Yes Ground Fault Isolation Detection I00kvSensitivity INSSAI.LATIOWSPECJF lCATIONS Maximuminverter Efhclency 97.7 I 98,2 96.3 98.3 96 _1 48 96 `T Maximum Allowed System Voltage1000 Vdc CEC Weighted Efficiency ':, 9715 98 99' @Z4 97.5 1 97.5 19+ 97.5 gp Dimensions(WxLxH) 128 x 152x27.5 15 x5.97 x 1.08 141 x212 x35!5.55 x6.34 x 1.37 mmlin S 775 @224OV .. ........... ... ..- Nighttime Power Consumption <2.5 4 VJ Weight(including cables) 770/1.7 930 f2-05 g flh ADDITIONAL FEATURES _ _ _----- input Connector MC4 compatible_ Supported Comm urtication Interfaces j 85485,RS232,Ethernet,Zig_Bee(optional) .. ... .. ..... .. .. ........I ..... .... ...... ........,,.... ......, .. ........... ... .,. ... ...... Output Wire Type/Connector Double Insulated:Amphanol 114 Revenue Grade Data,ANSI C1 2A Optional°j Rapid Shutdown-NEC 2014690.12 Functionalityenab.ledwhenSolarEdge,rapidshutdownkitisinstalledre OutputWlreLength 09513.0 13/3.9 m/0 STAN DA R D'CO M PLI A N CE Operating Temperature Range 40-,+66 1-40-+185 Safety .,,.., „...... .. .... .... .. ... ..... ..... _ ., ,. UL1741_,UL1699B,LIL1998,CSA 22.2 ,...., ,- .. Protection Rating IP68/NEMASP Grid Connection Standards IEEE1547 - . .. .. .. ...... ... .. I .. .. ... ..... .. .... .... ... ..... .. .. ,. .. .,. .. Relative Humlorty 0-10Q % _ Emissions FCC partly class B I --`-0 Emissions INSTALLATION SPECIFICATIONS Irl Rated STC power of the module Module of up to+5%power tolerances allowed AC output conduit size/AWG range 3/4"minimum f 16-6 AWG 3/4,.. minimum 16-3 AWG . _ DCinput conduit size/k of strings/ ! 3/4"minimum/i-2 strings/ P,V SYSTEMQESIGN.UStNG SOLAREDGE INVERTER SINGLE PHASE THREE PHASEZOBY THREE PHASEIVA TECHNOLOGY 3/4'minimum/1-2 strings f 1G-6 AWG Ath!G,range I . .. .. .. 144 AWG .. .. C h Safety "c "' "' "" " "" """' "" - Minimum String Length(Pottier Optimizers) 8 10 1B 792 Barber Lane,Milpitas,CA 95035 i _ B Dimensions with Safety Switch 30.5 x 12.5 x 10.5/ In J 3D-5 x 12.5 x 7.2 1775 x 315 x 164 www.aivatechnolog tom,Phone:408 314 9589 .. .. ... .. 775 x 315 x 260 _ nnn. Maximum String Length(Power OpGmFiers) 25 - 50 y Weigh)with Safety Switch 11-2/23-2 _ 54.7/24.7 88.4 J 40.1 Ib/kg Natural , Maximum Power per String 5250 6060 12750 W convection j Parallel Strings of Different Lengths or Orientations Yes Cooling Natural Convection I and internal Fans(user replaceable) fan(user 1 Noise ...... .. ...... _<.25 <50 dBA .......... ....... ..... .. .... . ...... .. ... ........ ............ PROJECT: ..., . ........ ... ... ... ........... .. ......... Mln.-A4ax.OperatingTemperature 4.48KW PV SYSTEM 43 to+140/-25 to+60(-40 to+60 version available ) F/°C 31 Rabe -... - . - .. For othare-anal setons' .... .. ..� ... ... ........ ... .. ..... .. ....... ... . Protection Rating NEMA 3R .......... . .... ..........� ................ ............ . ................. ......... . .... ..........- ...... ........... .... ............ .......... SOLAR ROOF PROJECT {" 0 please cemzct5olartdge support rl A higher current source may beused;thehwener will limit rtsinput curtentto thevalues stated nl Revenue grade imend P/1:5EmoxA-U5Q0@ Nf 1R2(for 75)DW mverte{SE760DA-USU0214NR2). WI Rapid strutdmvn kit Pj N:5t10D0-RSD-51. PI-40 version P/N:Sb=uA-USDD-JNNU7(W 7500 W 1-n-SE7r.00A-US002NNU4) PROJECTOWNFIt Rao Dayaneni 21155 Lauretta Drive,Cupertino,CA 9501 sunsPEC 8 DRAWING: tip r SOI&Edge Power Optimizers ® A EQUIPMENTS: INVERTER SPECIFICATION SHEET: E-4 � J 9 nSECTION VIEW AND ROOF FRAM Q SCALE: 1/2"=1'-0" REVISION DATE NO 03/03/2016 ' s 8�0'j. r o 2X6@24" RAFTER c c L CONNEXTION DETAIL A ;CONNEXTION DETAIL B q)CONNEXTION DETAIL C ROOF CONNECTION MID CLAMP END CLAMP e rx - B B AIVA TECHNOLOGY 792 Barber Lane,Milpitas,CA 95035 Existing Roof Structure www.alvatechnology.com,Phone:408 314 9589 Detail B - Mid Clamp to Rail ao Detail A - Roof Connection Detail C - End Clamp to Rail PROJECT: 4.48KW PV SYSTEM SOLAR ROOF PROJECT SOLAR PANEL Rao Dayaneni IronRidge Rail 21155 Lauretta Drive,Cupertino,CA 9501 SOLAR PANEL A Ebb MID CLAMP MID CLAMP SHEET.. S-1 REVISION DATE NO ' D " :�. �_ I RON RI DGE XR Rail Family XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes_Each size supports specific Solar Is Not Always Sunnydesign loads,while minimizing material costs.Depending on your location,there is an XR Rail to match. Over their lifetime solaranels experience countless P xP extreme weather events.Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof,and snowfalls weighing -- -- enough to buckle a panel frame. XR Rails are the structural backbone preventing these results.They resist uplift,protect " ) XRio XR1oo XR1000 against buckling and safely and efficiently _ _ XR10isasleek,low-profile mountmg XR1IIOisthe ultimate residential XR1COO is2heavyweight among transfer loads into the building structure. `` rail,designed for regions with light or mounting rail,It supports a range of solar mounting rails.It's built to handle Their superior spanning capability : no snow.It achieves 6 foot spans,while wind and snow conditions,while also extreme climates and spans 12 feet or requires fewer roof attachments, c remaining light and economical. maximiang spans up to 8 feet. more for commercial applications. �. �. , C reducing the number of roof G spanning capability 8'spanning capability 12 spanning capability C penetrations and the amount E 9 w y ,� Moderate loan capability Heavy load capability Extreme load capability ` Clear anodized finish Clear&black anodized finish Clear anodized finish of installation time. Tf Internal splices available Internal splices available Internal splices available w Rail Selection The following table was prepared in compliance with applicable engineering codes and standards.Values are } based on the following criteria:ASCE 7-10, Roof Zone 1, Exposure B, Roof'Slope of 7 to 27 degrees and Mean Building Height of 30 ft. Visit Iron Ridge.com for detailed span tables and certifications. Force-Stabilizing Curve 100 �. Stoped roofs-generate both vertical and lateral 1. t forces on mounting rails which can cause them 120 None —to bend and ovist The curved shape of XR Rails I aA 140 XR10 i XR100 XR1000,' is specially designed to increase strength in both directions while resisting the twisting.This unique , • `,". _ _ ��� B feature ensures greater security during extreme 160 } B AIVA TECHNOLOGY weather and.a longer system lifetime. 100 a_ _° 792 Barber lane,Milpitas,CA 95035 w ) www.aivatechnology.com,Phone:408 314 9589 120 Pi 10-20 — 1 140 160 i ! 100 i 30 PROJECT: 160 i 4.48KW PV SYSTEM Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials ; 100 XR Rails are fronRidge offers All XR Rails are made of marine-grade 40 j SOLAR ROOF PROJECT compatible with a range aF tilt leg afurriinum alloy,then protected with an 160 FlashFoot and options for flat anodized finish„Anodizing prevents surface } other pitched roof roof mounting and structural corrosion•while also providing 50-70 160 f¢ vawxrawrr� attachments. applications, amore attractive appearance. ��}' eo s0 160 Daean Rao eni -_--___ 21155 Lau a Drive,Cupertino,CA 9501 REM ., NOV ,.. w [a KNEW >„k�:.« ,m .,,�', '.. DRAWING: A EQUIPMENTS:RACK SPECIFICATION &INSTALLTION--IRONRIDGE RAIL SYSTEM seEEr: S-2 ,o�' k.IRONRIDGE Zl IRONRIDGE REVISION IRONRIDGE Installation Manual RailswithlntegratedGrounding Installation Manual Rails Installation Rails DATE NO Component List Assembly Steps Rail to Rail Expansion Jamt The lronRidge Standard and Light Rail System with Integrated Grounding contains the following parts: Step 1.Install Applicable Roof Flashing and L-feet A. Insert splice into hist rail then secure splicewith self-drilling screw. 03/03/2016 B. Attach hardware and Grounding Strap 19AWGl one(l)Inch from end at rall as shown below. Standard(XRS)and Light(XRLI Rail Internal Splice A. Determine the appropriate flashing required for your roof type and C. Next,slide the second rail over the splice and attach other end of Grounding Strap with hardware.(Use Grounding Strap only on project.Instal flashing per manufacturer's requirements. rMI-Ith lugs) t Attaches to L-loot and Provides a structural connection B. Mount all the L feet to the roof in the desired locations using a minimum D provides support when connecting rails. �:- 3116"x3'lan La BolL The 5/16'La Bolt attached to a structural roof v�y� 9 9 9 Sem-nnlun0 ecrew t'rrom Eagc far the PYmodulez member such as after.For metal or die teats,Install aMount suitable �.� h/4'He.Nut iorgac to6<in ms Seu-arn6ng crew nr the app'lcaten,per mount manufacturer%rpqulmerpnls. -- / Groandln I'From Edge(2s) 7illat / r ` �--- f�Grori Srap 1 u. g �114'Hex Nul Torque,ea m-Ibs Note:7ie•oafanarhmeni spodngs are d¢hned by many vadobles such as"he �./ �) ��• X11 /� P Grounding strap l G-owding l\ c d'clans,mltypeandmofsrructum.Relerro the lrongidgr Crn hmtlon;etten r\ �� - l �Svar 1/9"I t1011 / C online Design Assistant dnern!ne appmpdare orachmenr spacing. <w 0 \ `alt<•ract r.. Step 2.Attaching Rails To L-Feet I/2'Gep L-Foot End Clamp A. Slide the 3/6'bol[s into rail side slots Space bolts to match the L-foot spacing. Pa _-"� 1 `,d Attaches to the roof and Secures PV modules to rails I `" f Centered'Tram Edge JJJ B. Loosely,attach rail to L-feet using 3/R'hardware.Position roll at desired ��__- {,.; ,1 Centered 1"From Eage 3'inside Rail supports rails ��! utilltIng lherail top slot. 6-1—al aril rurvve se a°inaus 7omue to 641n-Its helghland level.Once torque 3/a'hardware co 2361n-Ibs(dry) I "(�e`�•.�t4 Mnvpin StM3 for Rail to RaBrnnernnnsthpnrepparstpp7fnrpacn Standard Rail Light Rail L-foot connection. 1 �, f '�ti• Note:Attaching rails to L-rest may beperfonncdbefon•oraRermakieq mfto- ��• ml!rnnnecOonA depending on lhelmta7/erY p.•eferrnce --_ _,.••'� QStep 4.Equipment Grounding Mole:In orderto prope'b ground the W macules and/ronR/dpe comporten:s to the equipment gmun4 a grounding lug or Lay-In Lug most Step 3.Rail to Rail Connections be attached to one(U rail near the end of each mw.This connection requires the use of one ofthe two lollowrng lugs Grounding Mid Clamp End Cap ®Note-Thls rnnnrrtlnn requires propergroundingnn mils with nrnrmdrinritis byusing one ofthe twofalbwinn Rnll fn Rnfi Ccar-11 n IronRldge Grounding Lug methods Formlkvwthoutlugtuse the Internal Spbre and self-ddltng screws withara the grounding strop andstorw•achers(Sep Pa9PRJ.Far Secures PV modules to rails Caps off the end of the rail =crewing SOfeet ofmil ironR'dyere—irrends the Rallto Rail ExpansionlolnL Exparril-Iointsprevent!impatersholbucclrng ofmih 1. Using a 13/64'or 07 drill blL drill a hole through one side oftheStandard Rail(both sides for Light Rail),a minimum of r/,'from and provides grounding to � and prevents the collection due rothermolPrpanslon.At thilnstalieff can,a Rail to RaIIEpansicn joint may oho 0e,oul al lengths fless ths nthan SO feet ofmil the end of therail;roughly centered on Internal cavity of rail as shown below.(Debur as needed) th a rail and between the two r of debris Inside rail. 2. Next assemble the Gounding Lug with the provided f 1032 Machine Screw,B lO Star Washer and x lO Kep Nuc adjacent modules. Rail to Rail(Basic)Connection 3. Install a minimum 10AW G solid copper grounding conducting wire.Torque to 20 in-Ibsfor 10AW C.,25 In4bs for aAW G,or 35 In- lbs far and 6AWG. A. Insert Internal splice Into hist rail then secure sp6cewith hardware and Grounding Strap(9AWG).Attach and assemble as shown. D. Next slide second rail over splice and secure with hardware on opposite end of Grounding Strep. .+. C. Repeat this procedurefor remeining Roll la Rall Connections.IUse Grounding Strap only on roils with lugs.) ,..' Star Waste. ens C Sell-drillir y scrrn ercd titan Edge /f Tprque to en inJbs Sel(Eriging:crew Conferee t'From Edge dict Kep Nut 5 rWasher Sur WasherTorque to 84 in'bs 'tar/Washer Grounding Solutions Wire Clips _ /� J / - /-✓� v Groundng Grounding / 310 Kep Nut -P / aid Hoa Rolt ololiaxBort Rall to Rall Grounding Strap d Wremane star rails. 1S'rap \y �•`�, us ` F% Trueto 32 in-Ibs Gmundmg Lugs g Pan genets _ /\\ :� p r' C {4 � q Dal5 G,-A ,,. _ (. /��Twque to 32 in-Ibs I F•l `1.200-lbs fa Torque 910 EEI Screw Tn•aue Io 20 In-lbs(or IOA1YG to 20 In-Ibs far 10AWG T3'inslde Ran 6'imidc9aiom� Cente,ed l'FrEdge- Cent-.117Edgc Standard Rail Light Rail To1q1e1184in-Ibs Torque re.4 to-b> Standard Rail Light Rail f >uppuriyx hanridge.wnt I 1600)227-9323 P.gea 2019 v1.,1 >uppuuts I hpnrldge nn I laco)222.95" Page. 2013vt.ts >uPPprtt: I iranridye-cults I ieoo).7-9923 Pages 2019v1.11 IRONRIDGE .�1 IRONRIDGE � IRONRIDGE Installation Manual Rails Installation Manual RailswithlntegratedGrounding Installation Manual Rails with Integrated Grounding Grounding Mid Clamp Electrical Considerations Wiley Grounding Lug(WEES 6.7) ® D. Once the his[PV module is In lace,loosely hardware and Grounding Mid Clam as shown below. Note.IronRid Standard XRS and tight RLI Atounfin S stenrswiih joie dV��' '� p ) g p ye ( J g (X ) g y graced Grounding must br used with UL17037,sted 1. Installgmrmdinglug per manufacturer's recommendations as shown below(sameforboth Ughtand Standard Rails). E. Nex4sflaesecond PV module Into position underneath theGrounding Mid Clamp and secure with hardware.Ensurethe Pvmudule mldrnual behntollydperwmudurrnunulacwrerllrutulkrtiun hutructram.ARrfeadcuf)msuilubunand prueedurrs should 2. Install minimum G-tOAW G solid copper grounding conducting wire. Grounding!Aid Clamp teeth are In contact with both of the PV module frames and the T-Bolt Is properly aligned in track.T-Bolt be corductrd by sylll<d,Ifcen>rd and bonded ekclricwru ur solar cwrtmcror.All warp must comply wdh all nationu(state and local indent should be perpendicolai to rag. Insmllauon procedums,prodi,a and safety standards.These standards include but are not 9mfied ro app6mbfe Netlonaf Eleemeai Cade BF. Repeat steps for other clamp and modules. (NEC-)sections.Notional E.resrimHvtallodonStandards(NEIS-4ULStandards,and05HARegufacom B AIVA TECHNOLOGY �1/4'Hex nutTwque to 1011-as I/4'Lock Washer p Basic Grounding Diagram 792 Barber Lane,Milpitas,CA 95035 1/4'H-Nut www.alvatechnol A. IronRldge Grounding Lugs and Wiley Electronics,LLC#W EEE-6.7 are approved for use with this system. �y.com,Phone:4083149589 ::.•,.` d.a Grounding I orque to 84 lnTbs B. The Rail to Rail(Splice)Connection requires proper grounding on calls with grounding lugs by using one of the two Railto Rail _ 1/4'He.FoltTorquc to7it lbs -----,Mid ClompConnection methods described In Step 3 of this manual. x werb ,,.� = _ :_ 114 = C A minimum 10 AM'G solid copper grounding conductor must be used to property ground the system,as shown below. _. -T-Bolt - - W PROJECT: End Clamp 4.48KW PV SYSTEM G. Sncure the last PV Module with an End Clam tin st bove. SOLAR ROOF PROJECT Step S.Installing Modules End Clamp Step 6.Installing End Caps A. Place the first PV module In position on therails.Moduleshc uld be a rnlNmum of 15'fam end of r.IL A. Firmly press End Caps an with hand or rubber mallet --O --____- U -______ C _- __ O _----- O _----_ O B. Next,secure End Clamp on rail as shown.Ensure End Clamp is securely hooked over top of module. C. Repeatwith end clamp on the other rail. \\ Rao Daya n e n i 21155 Lauretta Drive,Cupertino,CA 9501 \\ .ill \�`' ------- ------- -- -- ------- ------- y i l/4'H ex Nut r f l ai •,, •'. J 71 _-,.:- O _______ O __ __ O ____--_ O _______ O'� _. J 11 :• -y" -tort �! DRAWING: I OI F11d Clamp • Torque lu 65 In-Ibs / )' LLl + 114'H"Bolt - - \�r',1� _ I I 'b \\ 1- ti GroundingL.ug A EQUIPMENTS:RACK SPECIFICATION �� L! �`•= �i; �'�) MinimumlOAWG &INSTALLTION--IRONRIDGE RAIL o Mid Clamp copper grounding INTERGRATED GROUNDING = canductnr Splice with GroundingStrap m Splice without Grounding Strap Or m�nR SHEET: >uPputlt I i nridge.cunr I 1000)227.93±] Page e tats vl.l3 >appuup l Irpnddye.carn I 180012279323 Pages tats v1.13 >uppwl@ I nanridge-in I 11100)227-9325 Page. 2013 v1.11 S-3