Loading...
B-2016-1478 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERIT NO:B-2016-1478 20151 NORTHWOOD DR CUPERTINO,CA 95014-0554(316 36 037) (MR UNGER) SOUTHSAN FRANCISCO,CA 94080 OWNER'S NAME: SCHORR ANDREW J TRUSTEE&ET AL DATE ISSUED:03/07/2016 OWNER'S PHONE:408-314-2957 PHONE NO:415-724-0299 LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO: License Class B Lic.#982722 Contractor(MR UNGER)Date X BLDG —ELECT _PLUMB MECH X RESIDENTIAL I COMMERCIAL I hereby affirm that I am licensed under the provisions of Chapter 9(commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. JOB DESCRIPTION: KITCHEN REMODEL(80 SQ FT),BATHROOM HALL REMODEL(40 I hereby affirm under penalty of perjury one of the following two declarations: SQ FT),MASTER BATHROO REMODEL(80 SQ FT). t. I have and will maintain a certificate of consent to self-insure for Worker's _ Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. 2. I have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$12000.00 APPLICANT CERTIFICATION I certify that I have read this application and state that the above j information is correct.I agree to comply with all city and county APN Number: Occupancy Type: ordinances and state laws relating to building construction,and hereby 316 36 037 1 authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save indemnify and keep harmless the City of Cupertino against liabilities,judgments,costs,and PERMIT EXPIRES IF WORK IS NOT STARTED expenses which may accrue against said City in consequence of the WITHIN 180 DAYS OF PERMIT ISSUANCE OR granting of this permit. Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal 180 DAYS FROMI AST C ,LED INSPECTION. Code,Section 9.18. 116 Issued by:ALEX VALLELUNGA �S:ign�ct�,� Date Date: / OWNER-BUILDER DECLARATION RE-ROOFS: I hereby affirm that I am exempt from the Contractor's License Law for one of the All roofs shall be inspected prio�to any roofing material being installed.If a roof is following two reasons: installed without first obtaining an inspection,I agree to remove all new materials for 1. I,as owner of the property,or my employees with wages as their sole inspection. compensation,will do the work,and the structure is not intended or offered for sale(Sec.7044,Business&Professions Code) Signature of Applicant: z. I,as owner of the property,am exclusively contracting with licensed Date: contractors to construct the project(Sec.7044,Business&Professions Code). I hereby affirm under penalty of perjury one of the following three declarations: ALL] COVERINGS TO BE CLASS"A"OR BETTER 1. I have and will maintain a Certificate of Consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the HAZARDOUS MATERIALS DISCLOSURE performance of the work for which this permit is issued. I have read the hazardous materials requirements under Chapter 6.95 of the 2. I have and will maintain Worker's Compensation Insurance,as provided for California Health&Safety'Code,Sections 25505,25533,and 25534. I will by Section 3700 of the Labor Code,for the performance of the work for which maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the this permit is issued. Health&Safety Code,Section 25532(a)should I store or handle hazardous a. I certify that in the performance of the work for which this permit is issued,I material. Additionally,should use equipment or devices which emit hazardous shall not employ any person in any manner so as to become subject to the air contaminants as defined by,the Bay Area Air Quality Management District I will maintain compliance with I'he Cupertino Municipal Code,Chapter 9.12 and Worker's Compensation laws of California. If,after making this certificate of the Health&Safety Code,Sec'ons 25505,2533,and 25534. exemption,I become subject to the Worker's Compensation provisions of the Labor Code,I must forthwith comply with such provisions or this permit shall weerfhorl-ed ager be deemed revoked. Ids a APPLICANT CERTIFICATION CONSTRUCTION LENDING AGENCY I certify that I have read this application and state that the above information is I hereby affirm that there is a construction lending agency for the performance correct.I agree to comply with all city and county ordinances and state laws of work's for which this permit is issued(Sec.3097,Civ C.) relating to building construction,and hereby authorize representatives of this city Lender's Name to enter upon the above mentioned property for inspection purposes. (We)agree to save indemnify and keep harmless the City of Cupertino against liabilities, Lender's Address judgments,costs,and expenses which may accrue against said City in consequence of the granting of this permit. Additionally,the applicant ARCHITECT'S DECLARATION understands and will comply with all non-point source regulations per the I understand my plans shall be used as public records. Cupertino Municipal Code,Section 9.18. Licensed Professional Signature Date � CONSTRUCTION PERMIT APPLECA►TE�EV COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION 10300 TORRE AVENUE• CUPERTINO,CA 95014-3255 (408) 777-3228• FAX(408)777-3333 • building0cupertino.orq CI`dPEE2T[NO ❑NEW CONSTRUCTION ❑ ADDITION ��TERATION/T_I ❑ REVISION/DEFERREDJ/DEFERREDORIGII,,TAL PERMIT n PROTECT ADDRESS / :C �/© /-� no W, APN n OWNERNAME �,Wy9 WV � PHONE F6AIL STREET ADDRESS CITY, STATE ZIP CA FAX CONTACT NAME - PHONE Q E /,X �' d� ► 7" 'i/ STRE T ADDRES� n�/^^ n ,- /� CITY,STATE,f P (' �J%� FAX (� f � ❑ OWNER ❑ OWNTER-BUILDER ❑ OV,TTERAGENT ❑ CONTRACTOR ❑CONTRACTORAGENT ❑ ARCHITECT ❑ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME �✓ LICE SEM LICENSE TYPII BUS.LIC n jJ l\`]n I COMPANY NAME E-MAIL FAX STREE �2C.� CITY,STATE,ZIP y 15 V��C?_ v s/ / 7 ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS.LIC# COMPANY NAME E-I\ZAIL J FAX STREET ADDRESS CITY,STATE,ZIP PHONE DESCRIPTION OF"WORK i r no .�1/ �� �,� , EXISTING USE PROPOSED USE CONSTR.TYPE #STORIES USE TYPE OCC. SQ.FT. V UATION(5) EXISTG NEW FLOOR DEMO TOTAL AREA AREA AREA NET AREA FC ATHROOM KITCHEN �WREMODEL HER REMODEL AREARO/�j REMODEL AREA AREA �J 1 r PORCH AREA DECK AREA TOTAL DECK/PORCH AREA GARAGE AREA: DETACH E]ATTACH #DWELLING UNITS: 1S A SECOND UNIT ❑YES SECOND STORY [:]YES BEING ADDED? ❑NO .ADDITION? I-]'NO PRE-APPLICATION ❑1'ES IF YES,PROVIDE COPY OF IS THE BLDG AN ❑YES RECEIVED$ TOTAL VALUATION: PLANTNING APPL# ❑NO PLANNING APPROVAL LETTER EICHLER HOME? ❑NO U r By my signature below,I certify to each ofthe f lowing: I a the property owner or authorized agent to act on the pro owner's behalf. I have read this application and the information I have provide i correct. I ave read the Description of Work and verify it is accurate. I agr e to co aply with all applicable local ordinances and state laws relating to building�njtction. authorize representatives of Cupertino to enter the above--ii ed pro erty or inspection purposes. Signature of Applicant/Agent: Date: r SUPPLEMENTAL INTFORI\4ATION QUIRED PL T\cxECI.r1'PE.,,, ,,,r ROUTInG:SLIP, New SFD or Multifamily dwellings: Apply for demolition permit for k - •'O�ER THE COU\TER; �BUILDI\G PLAA'REQ IE\'4' � ' existing building(s). Demolition permit is required prior to issuance of building permit for new building. L7 EGRESS ❑ PI 4\\Il�'G PLAN REA IE�1':f _Commercial Bldgs: Provide a completed Hazardous Materials Disclosure sTA\DARD ❑ PUBLICAi'ORLS form if any Hazardous Materials are being used as part of this project. ' ❑ LARGE ❑ FIRE DEPT S _Copy of Planning Approval Letter or Meeting with Planning prior to submittal of Building Permit application. V IvLAaox ❑ S A\ITART'SE�1 ERDISTRICT ❑ .EVVIRO\A4ENTALHEALTH' Bldg 4pp_2011.doC revised 06/21/11 Assessor's Parcel Number: 31U " z - C) Plumbing Notes: �j 1. Faucets in kitchens,wet bars,lavatories,laundry sinks,etc shall have a water flow not to exceed 1.8 gallons per minute @ 60 psi.(CPC 403.6) Name of Owner: r✓�1��� Electrical Notes: 2. The installation of smoke alarms in all of the following areas shall be provided: (R314.3) a. On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms. Contact Person: �� Phone:_ —[ J L�� `� b. In each room used for sleeping purposes. C. In each story within a dwelling unit,including basements but not including crawl spaces and uninhabitable attics. r7 n t I l O ,() u� n / L 3. Approved carbon monoxide alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on every level including Project Address: J�if� l l U� basements in dwelling units that have fuel-fired appliances or attached garages.(CRC R315.1) 4. A minimum of two 20 amp small appliance branch circuits shall be provided for all receptacle outlets in the kitchen,dining room,pantry,or other similar areas.(CEC Scope of Work: t �� - 210.11(C)(1)) 5. At least one 20 amp branch circuit shall be provided to supply bathroom receptacle outlets.Such circuits shall have no other outlets.(CEC 210.11(C)(3)). -y� � � r n! �� ,} r 6. In every dwelling unit,fixed appliances such as food waste grinders,dishwashers,washing machines,dryers,laundry tray locations,built-in refrigerators or freezers, Code Editions: 2013 California Residential Code ( ► V v ✓y'l�t D i �(fJ 1 �,� furnaces,AC units,built-in heaters or any other fixed appliance with a motor of/.h.p.or larger shall be on a separate 20 amp,branch circuit. 7. All receptacles in bathrooms,garages,accessory buildings,outdoors,crawl spaces,unfinished basements,kitchens(where receptacles serve countertop surfaces), 2013 California Plumbing Code laundry,utility,wet bar sinks(within 6 feet of the edge of the sink),shall have ground-fault circuit interrupter(GFCI)protection.(CEC 210.8(A)) 2013 California Mechanical Code 8. In all areas specified in 210.52,all non-locking type 125-volt, 15-and 20-ampere receptacles shall be listed tamper-resistant receptacles.(CEC 406.12) 2013 California Electrical Code 2013 California Energy Code Energy Code mandatory lighting measures: 1. All permanently installed high efficacy luminaires shall be switched separately from low efficacy luminaires.(150(k)(7)) ' 2. Permanently installed lighting in Kitchens shall be high efficacy luminaires.Up to 50%of the wattage of permanently installed lighting in kitchens may be in lights that are not high efficacy.(150(k)(8)) +CUPERTINO F' FGl 3uilding Degrtmert MAR 0 7 2016 REVIEWED FOR CODE COMPLIANCE Reviewed By CO(v'".1L!NFY DEVELOPMENT DEPARTMENT BUILDING DIVISION-CUPERTINO APPROVED TM c t of C!-ins sand specifications MUST be kept at the construction. It is unlawful to make any v" 7;. or alterations on same,or to deviate n-,,without approval from the Building Official. ,!-.inr7of this plan and specifications SHALL NOT rpt or to,Ue an approval of the violation ofty Ordinance or State Law. _4k 3 -I U :Zug-_U Z TI l 9 EXISTING KITCHEN FLOOR PLAN KITCH N FLOOR PLAN Assessor's Parcel Number; `� Plumbing Notes: C ` 1. Water closets shall have an average water consumption of not more than 1.28 gallons per effective flush.(CPC 403.2) Name of Owner: -JC`\0Vr- 2. Shower heads shall have a water flow not exceed 2.0 gallons per minutes @ 80 psi.(CPC 408.2) i 3. Faucets in lavatories shall have a water flow not exceed 1.5 gallons per minutes @ 60 psi and shall not be less than.8 gallons per minutes at 20 psi.(CPC 403,6) ` (� ''j �] + 4. Shower stalls shall have a clear interior finish area of 7.1 sq.ft.and be able to accommodate a minimum 30 inch circle at the threshold level.These clearances shall be Contact Person: VN'4 f V1 '�� Phone; " t�� 1 �� O `��C� maintained up to a height of 70 inches able the shower drain.(CPC 408.6) 5. Shower compartments and walls above bathtubs with Installed shower heads shall be finished with a smooth,nonabsorbent surface to a height not less than 72 inches M �� ((0).(CRC R307.2) Project Address: 5.� 6. The maximum hot water temperature discharging from the bathtub,shower and whirlpool bathtub filler shall be limited to 120 degrees Fahrenheit The water heater _' ' / � fJ�'�_ I � thermostat shall not be considered a control for meeting this provision.(CPC 409.4&408.3) Scope of Work: ✓ C,�,r✓� �/��(�(� CPg1�? � 7. Water closet shall be set minimum 15 Inches from Its center to a side wall or obstruction and 24 inch clearance In front of water closet.(CPC 402.5) J Electrical Notes: 1. The installation of smoke alarms in all of the following areas shall be provided; (R314.3) Code Editions: 2013 California Residential Code (� / �Q"7 a. On the ceiling or wall outside of each separate sleeping area in the Immediate vicinity of bedrooms. b. In each room used for sleeping purposes. 2013 California Plumbing Code C. In each story within a dwelling unit,including basements but not including crawl spaces and uninhabitable attics. 2013 California Mechanical Code 2. Approved carbon monoxide alarms shall be installed outside of each separate sleeping area In the immediate vicinity of the bedrooms and on every level including basements in dwelling units that have fuel-fired appliances or attached garages.(CRC R315.1) 2013 California Electrical Code 3. At least one 20 amp branch circuit shall be provided to supply bathroom receptacle outlets.Such circuits shall have no other outlets.(CEC 210.11(C)(3)) 2013 California Energy Code 4. All receptacles In bathrooms,garages,accessory buildings,outdoors,crawl spaces,unfinished basements,kitchens(where receptacles serve countertop surfaces), laundry,utility,wet bar sinks(within 6 feet of the edge of the sink),shall have ground-fault circuit interrupter(GFCI)protection. (CEC 210.8) Mechanical Notes; 5. In all areas specified in 210.52,all 125-volt, 15-and 20-ampere receptacles shall be listed tamper-resistant receptacles. (CEC 406.11) 1. Bathroom vents shall terminate not less than 3 feet from openings and property lines,(CMC 504.1) Energy Code Mandatory Measures: 1. All permanently installed high efficacy luminaires shall be switched separately from low efficacy luminaires(150(k)(7)) r 2. Permanently installed luminaires in bathrooms shall be high efficacy luminaires OR are controlled by an occupant sensors(s)certified to comply with Section 119 that C U P E RTI N O does not turn on automatically or have an always on option.(150(k)(10)) building Dena tfl'tent �! r $' MAR 012016 REV!JF5WEU FOR CODE COMPLIANCE r--�i.eviewed By 1t 1 r-I-w tufa shower flauc_et tiles ;:;Qpe of work new fl_,or Vanity toilet hover Baan faucet li,ht .0 . ;iilty tile to . Q tub Le 1.28 ty .210151or fi 'f ;act d r N t �, � �J gfci tr existing P COMMUNITY DEVELOPMENT DEPARTMENT I BUILDING DIVISION-CUPERTINO APPROVEDLJ / c�ct lFaa '>rJ �• Thi set of plans and specifications MUST be kept at the Jo site during construction. It is unlawful to make any changes or alterations on same,or to deviate A therefrom,without approval from the Building Official. 1 The sfamping of this plan and specifications SHALL NOT ^ be held to permit or to be an approval of the violation of any, OW on of t Ordinance or Stat6 LaW. BY DATE PERMIT NO. Com' C - `" EXISTING BATHRC) iA 171 OCR PL^R'r SED BAT LqN