Loading...
B-2016-1483CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO: B-2016-1483 840 ROSE BLOSSOM DR CUPERTINO, CA 95014-4214 (359 04 019) ( AMERICAN SOLAR DIRECT INC) LOS ANGELES, CA 90025 OWNER'S NAME: CAMPBELL JOAN C DATE ISSUED: 03/08/2016 OWNER'S PHONE: 408-966-2867 PHONE NO: 310-569-4243 LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO: License Class B. C-10. C-39, C-46 Lic. #941069 Contractor ( AMERICAN SOLAR DIRECT INC ) Date 03/08/2016 X BLDG X ELECT _PLUMB MECH X RESIDENTIAL COMMERCIAL I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing _ with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. JOB DESCRIPTION: INSTALL (N) FLUSH -MOUNTED SOLAR PANEL ARRAY (4.86 KW I hereby affirm under penalty of perjury one of the following two declarations: AND 18 MODULES). 1. I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. n I have and will maintain Worker's Compensation Insurance, as provided for ,f by Section 3700 of the Labor Code, for the performance of the work for which Sq. Ft Floor Area: Valuation: $15000.00 this permit is issued. APPLICANT CERTIFICATION certify that I have read this application and state that the above APN Number: Occupancy Type: information is correct. I agree to comply with all city and county 359 04 019 359 ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and PERMIT EXPIRES IF WORK IS NOT STARTED expenses which may accrue against said City in consequence of the WITHIN 180 DAYS OF PERMIT ISSUANCE OR granting of this permit. Additionally, the plicant understands and will comply with all non -points a re ul ns per the Cupertino Municipal 180 DAYS FROM LAST CALLED INSPECTION. Code, Section 9. Issued by: ALEX VALLELUNGA 41, b� Signature Date 03/08/2016 Date: 03/08/2016 OWNER-BUILDERRE-ROOFS: I hereby affirm that I am exempt from the Contractor's License Law for one of the All roofs shall be inspected prior to any roofing material being installed. If a roof is following two reasons: installed without first obtaining an inspection, I agree to remove all new materials for 1. I, as owner of the property, or my employees with wages as their sole inspection. compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) Signature of Applicant: z. I, as owner of the property, am exclusively contracting with licensed Date: 03/08/2016 contractors to construct the project (Sec.7044, Business & Professions Code). ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER I hereby affirm under penalty of perjury one of the following three declarations: 1. I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the HAZARDOUS MATERIALS DISCLOSURE performance of the work for which this permit is issued. I have read the hazardous materials requirements under Chapter 6.95 of the i. I have and will maintain Worker's Compensation Insurance, as provided for California Health & Safety Code, Sections 25505, 25533, and 25534. I will by Section 3700 of the Labor Code, for the performance of the work for which maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the this permit is issued. Health & Safety Code, Section 25532(a) should I store or handle hazardous 3. I certify that in the performance of the work for which this permit is issued, I material. Additionally, should I use equipment or devices which emit hazardous shall not employ any person in any manner so as to become subject to the air contaminants as defined by the Bay Area Air Quality Management District I will maintain compliance with the Cupert' o Mpnicipal Code, Chapter 9.12 and Worker's Compensation laws of California. If, after making this certificate of the Health & Safety Code, Sec ' O5, 5533, and 25534. exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions or this permit shall Owner or authorized agent: be deemed revoked. Date: 03/08/2016 APPLICANT CERTIFICATION certify that I have read this application and state that the above information is CONSTRUCTION L :AGENCY I hereby affirm that there is a construction len ' g agency for the performance correct. I agree to comply with all city and county ordinances and state laws of work's for which this permit is issued (Sec. 3097, Civ C.) relating to building construction, and hereby authorize representatives of this city Lender's Name to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, Lender's Address judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant ARCHITECT'S DECLARATION understands and will comply with all non -point source regulations per the I understand my plans shall be used as public records. Cupertino Municipal Code, Section 9.18. Licensed Professional Signature Date 03/08/2016 CUPERTI NO ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNI TY DEVELOPMENT DEPARTMENT - BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3285 (408) 777-3228 - FAX (408) 777-3333 - buildinona cuDeriino.orq N W3 PROJECT ADDRBSS I APN R `3 5� 04 OWt`cRNAME' I PHONE E-MA.IL L STREET ADDRES I CIT STATE ZIP I FAX CON?ACT N.4 -ME PHONE STREET ADDRESS Cii i ATE. ZIP I F kx OWT7,-R ❑ ONVNER-BIT-DER ❑ O,,W---RAGEIv-T C0]\ -I -R -ACTOR ❑ CONTR4CTORAGiNrr ❑ ARcir—aCT ❑ iNGTmzR. ❑ DEV-LOPER ❑ -=xA.*KT CONT ORNAME ; \ J LI -'N NU} " S T BUS. LIC R 3� -7 rn tiC. COMPANY NAME I E-MAIL I FAX ST= D S I CI STA ZIP )O 3- Arl IAV. P 1\' r / `-- (vn�[/ ARC T ,TNGINE;R NAME I LICENSE NU1,/BER BUS. LIC 11 v�� 1 COA,PAN 4ME I E-MAIL _ FAX AA A\ 02A (G7 t STREET ADDRESS CITY, STATE, ZIP 014 PHONE tn P 17 44 USE OF - FD or Duplex [3 Multi -Family PROJF.CT IN WILDLAND PROJECT IN t❑ Commercial URBAN INTERFACE AREA ❑ Yes �1- No FLOOD ZONE ❑ Yes ❑ No STRUCr OL PANELS ❑ ELECTRIC VEHICLE C? �4RGING STATION ❑ SOLAR WATER F.EATING ❑ OT:LiR: FOR SOLAR PANELS. NUMBER OF PAIN7LS/L'NITS: KILOWATTS (COMA•iERCIAL OI\'L17: ' I TOTAL VALUATION: I h 00 ` eJ DESCRIPTION OF WOR}y, Tf'`126L difto 1 't�L506C WULA4 on liza 001'm; t,,O-� OA © J . n, By my signature below, I ce; if'�' to each of -the following.- I am the property o%\mer or authorized agent to act on the property o,�mer's behalf. I hav7e-I`ead this application and the information I have Prov' d is orr t. I have read the Description of Work and veru)' it is accurate. I agree to com y withal] applicable local ordinances and state laws relating o buildi Q on rue` on. I autho • -representatives of Cupertino to enter the above-ide `'feed roe for inspection purposes. Signature of Applicant/Agent: Date: SUPPL - dENTT INFORM4ATION REQUIRED fTCEGcED �L _ �, ova O��R ,Y COUItTER � -nt_ THE �-:_ 1`lPRESS.g t x =' UNIRSi�DARDs� _tea Nf PT!4pp_2011.doc revised 03/16/11 VICINITY MAP APPLICABLE CODES PROJECT DEVELOPER: OFFICE OF COUNTY ASSESSOR SANTA C L A R A COUNTY, CALIFORNIA �4 American 359 CALIFORNIA BUILDING CODE, 2013 EDITION (CBC) Solar Direct zz I CALIFORNIA RESIDENTIAL CODE, 2013 (CRC) rte; �+� s h CALIFORNIA ELECTRIC CODE, 2013 EDITION (CEC) American Solar Direct Inc. S. STELLING — ROAD t ---�_ -�" CALIFORNIA MECHANICAL CODE, 2013 (CMC) LICENSE C10/C46 4941069 ' TRACT N= 7866 T 6I �`; ..CALIFORNIA PLUMBING CODE, 2013 (CPC) 11766 WILSHIRE BLVD.. SUITE 500 LOS ANPH:(G424LE ANG(4E4)LES, 25 `t��.j/'=� ARTICLE 690, NEC 2011 CODE BOOK FX: (424)2146750 5 2 TITLE 24 RESIDENCE ENERGY EFFICIENCY STANDARDS http://w .ameriransolardlred.mm STT' I xv 23 3 3 COMMUNITY DEVELOPMENT DEPARTMENT ---- :0 L*9R„3- :z BUILE ING DIVISION - CUPERTINO CAL-FIRE PHOTOVOLTAIC INSTALLATION GUIDELINES I -21 APPROVED S---A; of plans and specifications MUST be kept at thE IL LLI _j > 2D 6 - sita Burin c nstruction. It is unlawful to make an 9 Y Z w LU r` o CD It m ❑CO PROJECT SCOPE -i-changes or Iterations on same, or to deviate CD 4.86 KW SOLAR ARRAY II therefrom, witho it approval from the Building Official. C) o m O PROJECT r '° B 4 The stamping oft is plan and specifications SHALL NO w ILD U LOCATION C R be held to permit or to be an approval of the violation (18) SUNEDISON MODULES �, � , Z f-- Q OO a Z J Y 9 e , Y a of any prov' ' of L Ordinance or State Law. MODEL NO. SE-F270 KZD-3Y c� Q o J U Q -�^±� ' ' '-4 w —r--...—...T...—... `I 19 —..�_.._ .—...T...—,t��- x ,, I BY IN (1) STRING OF 18 MODULES SOLAR EDGE INVERTER: U Z _I�„ 3 a 6 s O I� 12 13 Ian ON (1) (n W �5 _ ?4 ?3 22 11 PC7 /B !7 l6 /3 /a /3 l2 Is DATE 0 MODEL NO. SE3800A-US (240V) < O 0 Q �., ava -^ roe a.+ a area , ae+ PERMIT NO. U w 06 � T v/ Z � W ` ROSE e.+ ae err arr ars.x sa+ BLOSSOM eCTRACT N= 2536 ;, _pRIVE EXISTING 100A ELECTRICAL SERVICE PANEL B w _0 Q � > 6 � 00 s JW U JIti USE OF BUILDING:SINGLE FAMILY DWELLING 'MM'O Ua11EN¢ E SUM- AS453'CN (1) SOLAR EDGE POWER OPTIMIZER PER MODULE "I mg1w—W^"°” cv, anUr R & T. Colt. $M J27, En,sw a w �n3->ma (SINGLE PHASE) MODEL NO. P300 PROJECT NUMBER: AERIAL VIEW\SITE PLAN SHEET INDEX OP-00213236 T TITLE SYSTEM SIZE: 4.86 KW PV1 ROOF PLAN PV1.1 SIDE VIEW SIDE PROPERTY LINE SHEET TITLE: --- ——...__. __._............_._..........._..................... ...._...-..... .. ------ -- '.a �-- - ---; l PV2 LAYOUT + CONNECTION DETAIL E2 SINGLE LINE DIAGRAM TITLE SHEET E3 SIGNAGE co IT! Z EQUIPMENT SPECIFICATION PACKET ZxI ZO j� 1 Mauricio Rodriguez LICENSE C10/C46/C39 #941069 A! 0 D I — — MRODRIGUEZQAMERICANSOLARDIRECT.COM (626) 435-9221 APPROVAL STAMP m � o — — D! m ®A ro � m D PLAOT LAN z _ __ � ! C IP" �"I O E Y 0 0 ---------- - 1 Budding Dape nt DAr,E o ,6 City Revision/Issue Date m ® A� A MAR U 8 201! PLANNING DE D A CUPERTINO td 6i KJ4 V�7r R1C-��I CInt � 1=OR r 06 COMPLl 11 THIS DRAWING IS PROPERTY OF AMAWINGERICAN SCONFIOLAR RECTI C. .Z7 ! m C C ® InAMERICAN .ryY�1 rrly( �vl�w�� �� i.y ENGINEER STAMPS DRAWING ISCONFIDENTLAL AND IS ANDIS ONLY TO BEUSED DESIG N=0 BY N WITH WORK DESIGNATED BY ACFESs/0 G rRU/� N0. C70784 M EXP. 06/30/2017 In! ®TO ® 2,-7111 l 19'-5• SOLAR DIRECT INC. NO PART OF THIS DOCUMENT IS TO BE OTHERS THE PR OETHOUT R WRITTEN PE M' SSIION OF AMERICAN SOLAR DIRECT INC. CAD Revisions ER-CC-2/26/16 _— SIDEE 'tGE.- �%� CIV I\- TF OF CA��F�� 02/29/2016 scale: heet T Da,a: GENERAL NOTES PROJECT DEVELOPER: 1� T American U Solar Direct 1. SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED ON RESIDENTIAL.00" STRUCTURE. PV CONDUIT - 1 American Solar Direct Inc. EXTERIOR 3 2. DESIGN COMPLIES WITH THE 2013 EDITION OF THE CRC,AND 2011 NEC, AND ALL LICENSE C10/C46#941069 (PAINTED TO MATCH PV1.1 LOCAL ORDINANCES AND POLICIES. 11766 WILSHIREANGEL BLVD., suRE Soo LOS ANGELES, CA 90025 EXISTING COLOR) 3. THIS PROJECT HAS BEEN DESIGNED IN COMPLIANCE WITH THE CBC SECTION PH.(424)214-6750 50 FX: meri ansola di http:!lwww.amerlcansolardlrect.com 1609 TO WITHSTAND A MINIMUM 110 MPH WIND LOAD. I 4. THIS SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE (E) 100A LOCAL JURISDICTION AND THE UTILITY IS OBTAINED. L� ELECTRICAL >—�, SERVICE 5. THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. Z W t` O M (N) 100A SUB 6. IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE W J CO Q, d- 000 0-) ® UB PANEL GROUNDING ELECTRODE, IT IS THE CONTRACTOR'S RESPONSIBILITY TO U � Lo CH INSTALL A SUPPLEMENTAL COPPER GROUNDING ELECTRODE. Q O L PVD LU U (0 a) Z JB 7. EACH MODULE WILL BE GROUNDED USING THE SUPPLIED CONNECTION POINTS I`_ F- , Q 00 a, DC IDENTIFIED ON THE MODULE AND THE MANUFACTURER'S INSTALLATION 0 � U � Q (E)1 -STORY INV INSTRUCTIONS. Cl) c m O LLI �,e�°�� HOUSE / 8. REFER TO SHEET E.3 FOR SIGNAGE "CAUTION: SOLAR CIRCUIT' STICKER TO BE � co LLl (n z ZE U O INSTALLED EVERY 5 FEET AND 90 DEGREE BENDS OF CONDUIT. W 0 Z O W 9. ALL CONDUIT TO RUN ON THE EXTERIOR OF THE HOUSE (NO CONDUIT TO BE W O O) � 0.2 A ® FIRE CLR. GV INSTALLED IN ATTIC SPACE). � co U G ® �, / PLIEEE ���q PL AZ: 180°S 10. SOLAR PANELS SHALL BE INSTALLED WITH NO PORTION MORE THAN 18 INCHES ABOVE THE ROOF IMMEDIATELY BELOW. Q JO �\ Fc`R 1 0 PROJECT NUMBER: ,P GV \ ® AV / PV1.1 160 SLOPE 11. THE ROOF MOUNTED PHOTOVOLTAIC SYSTEM SHALL HAVE THE SAME OR BETTER LISTED FIRE -RESISTANCE RATING THAN THE BUILDING OP -00213236 PL �o��.. ROOF -COVERING MATERIAL. SYSTEM SIZE: 4.86 KW 12. REMOVAL OF A DWP-INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT GV DISCONNECT THE BONDING CONNECTION BETWEEN THE GROUNDING SHEET TITLE: 7® ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT PLUMBING VENT, 4" AZ: 270°W CIRCUIT GROUNDED CONDUCTOR. MIN. DISTANCE TO W E 13. ALL FIELD INSTALLED JUNCTION, PULL AND OUTLET BOXES LOCATED BEHIND ROOF PLAN SOLAR PANELLL MODULES OR PANEL SHALL BE ACCESSIBLE DIRECTLY OR BY DISPLACEMENT 160 SLOPE OF MODULE(S) OR PANEL(S) SECURED BY REMOVABLE FASTENERS. Mauricio Rodriguez LICENSE C10/C46/C39 #941069 M RODRIGUEZ@AMERICANSOLARDIRECT.COM AZ: 180°S 14. ONE- AND TWO-FAMILY DWELLINGS, LIVE PARTS IN PV SOURCE CIRCUITS AND (626) 435-9221 ,* [S::L: PV OUTPUT CIRCUITS OVER 150 VOLTS TO GROUND SHALL NOT BE ACCESSIBLE PFo\ �9 16° O PE TO OTHER THAN QUALIFIED PERSONS WHILE ENERGIZED. Clf fl—i 15. NO PIPING, DUCTS OR EQUIPMENT FOREIGN TO ELECTRICAL EQUIPMENT SHALL BE PERMITTED TO BE LOCATED WITHIN THE DEDICATED ABOVE THE tS�,PACC�E ELECTRICAL EQUIPMENT. ` J' g'�'� CU LR i It�iO r, � I��++.I � ('� C-,y���nn;; City Revision/Issue Date 1 CITY CORRECTION 2!26/16 16. "CAUTION: SOLAR ELECTRIC ST ONNECTEDABEL S`9 Bt COATED *SEE SHEET PV.2 FOR ROOF DIMENSIONS AND V1 1 P 1 1 ON MAIN SERVICE PANEL. wi TOF MTHiS ERICAAWINGI DIRECT HIS AMERICAN SOLAR DIRECT INC. THIS NTIAL AND IS ONLY TO BE USED WING IS INECONJUCTION STRUCTURAL INFORMATION. 17. GROUNDING: *UL LISTED SN LUG, BONDING CLAMP & CHANNEL NUT, STAR WASHER. RE1fIEV1r/EIS FOR CODE ��►�wLlAi�iCE ROOF PLAN SCALE= 3/32" = V-0" Reviewed By:��f Ni �� WITH WORK DESIGNATED BY AMERICANSOLARUMENT DIRECT STINCNO PART OF THIS DOCUMENT IS TO BE ABBREVIATIONS LEGEND AZ AZIMUTH JB JUNCTION BOX I—� PVD PV SYSTEM DISCONNECT THE PRIOR WRITTEN PERMISSION OFAMERICANDISCLOSED SOLAROTHEDI ECTIN . OF AMERICAN SOLAR DIRECT INC. (E) EXISTING UTILITY OPERATION CAD Revisions GV. GAS VENT® STRING NO. INV INVERTER WITH PL. PLUMBING VENT Q INVERTER NO. INTEGRATED M MAIN PANEL BOARD ER -CC -2/26/16 AV. AIR VENT ® DC SUB SUB PANEL DC DISCONNECT Customer hereby agrees that the ASD System will be installed on the side(s) of the premises reflected herein (see approximate panel layout above). Final layout of individual panels may vary depending upon obstructions discovered, Roof conditions, local (including any HOA), county and state laws, regulations, rules and codes. Scale: he PUS Date: Customer Name (Print): Customer Signature: PROJECT DEVELOPER: American ,...,...,................................,......,...,.....�.......,..,....„...,. -------- Solar LJ Solar Direct American Solar Direct Inc. LICENSE C10/C46 #941069 1 11766 WILSHIRE BLVD., SUITE 500 1 LOS ANGELES, CA 90025 PH: (424) 214-6700 . 1 FX: (424) 214-6750 httpl/www.americansolardirect.com �V- T-2_,rwt1 J > 111 Zw W c~fl� m 00O 11 1 U N LO 1 ► 1 Q Q � C.0 co ►r 1 1 wU C U) rnrnz F- 0 Q 00 w C o J U Q 1— 11 II 1 U� 00 o W 31-6 — w 0 Z ww0 1 w0Qow -) ;1- 2 1 O' U J O 1 PROJECT NUMBER: 1 SIDE VIEW 2 SIDE VIEW OP -00213236 1 SYSTEM SIZE: j 4.86 KW 1 1 SHEET TITLE: SIDE VIEW 'I 1 'I�` �' INO MauricioRodriguez LICENSE C101C46/C39#9 41069CUP— M MROORIGUE@AMEIAOARDIRECT.CO ,}►..;���� ��I cting ent (626)435 -9221PV. t r_rr 1 - REVIEWEL FOR CODE COMPP IAr�CE t Rev,avwed B Y.f!�!� City Revision/issue Date 1 CITY CORRECTION 2126116 1 1 Ill) 1 1 1 HIS DRAWING IS PROPERTY THTOF AMERICAN SOLAR DIRECT INC. THIS DRAWING IS CONFIDENTIAL AND IS ONLY TO BE USED IN CONJUCTION ((`) WITH WORK DESIGNATED BY AMERICAN SOLAR DIRECT INC. NO PART OF THIS DOCUMENT IS TO BE DISCLOSED TO OTHERS WITHOUT 1 THE PRIOR WRITTEN PERMISSION OF AMERICAN SOLAR DIRECT INC. CAD Revisions ER -CC -2/26/16 Sw�: Sheet PV1.1 Dale 3 SIDE VIEW 12" MAX. ,✓ CONNECTION DETAIL PROJECT DEVELOPER: OVERHANG / �American SOLAR PANEL EXISTING ROOF FRAMING 12" MAX. SECURING CLIPS VERHANG S" LI 2S.S. BOLT WITH LO A SPLIT LOCKK WWASHER � J Solar Direct SOLAR PANELT SNAP N PV MOUNAIN O 1 SNAP N RACK SNAP N RACK SERIES 100 STANDARD RAIL American Solar Direct Inc. SECURING CLIPS SYSTEM F,4, END CLAMP 76" S.S. FLANGE NUT LICENSE C10/C46 #941069 1­7�L SNAP N RACK® I- �" X 2" S.S. BOLT & Soy pP SNAP N RACK COMPOSITION ROOF FLASHING 16 MODULE S.S. LAG SCREW WITH FLAT WASHER 11766 WILSHIRE BLVD., SUITE 500 LOS ANGELES, CA 90025 9 o PV MOUNTING > . Z SYSTEM c -i" S.S. SPLIT WASHER 76" 2.5" MINIMUM EMBEDMENT IS STANDARD 1 PH: (424) 214-6700 FX: (424) 214-6750 http:// w .americansola dired.com POINT OF CONNECTION7 AT EXISTING ROOF FRAMING,MyN SEE LAYOUT BELOW FOR SPACING SEAL PENETRATION AND UNDER BASE WITH APPROPRIATE 8 1/I MAX SPACING POINT OF CONNECTION ROOF SEALANT EXISTING ROOF FRAMING AT EXISTING ROOF FRAMING, SNAP N RACK CHANNEL NUT J j 0')SEE LAYOUT BELOW FOR SPACING SNAP N RACK z V­ LU ti 0 LANDSCAPE PANEL (NTS) PORTRAIT PANEL (NTS) COMPOSITION L FOOT L11 00 (DI' CAN BE MOUNTED IN ANY ORIENTATION a_ 00 O Q o o (6 LO POINT OF CONNECTION DETAIL SCALE = NTS LFOOT BASE 0 53'-6" MOUNTING SYSTEM SPECIFICATIONS w v coM� z _ 11 �— U) MANUFACTURER: SNAPNRACK PV MOUNTING SOLUTIONS ia'-1o" iQ-a° y ��N } I__ � (-) CD Q SON 775 FIERO LN, SUITE 200 C/)U U pp O SAN LUIS OBISPO CA.93401 (n w Z z 0MODEL: 877.732.2860 EMAIL: TECH@SNAPNRACK.COM o6 O F--O *SERIES 100 RESIDENTIAL MOUNTING SOLUTION J Q LLI CL O C MATERIALS: W O �t * 6000 SERIES ALUM., * STAINLESS STEEL, GALVANIZED STEEL Q °O U CALCS +CERTIFICATIONS: ® *ASCE 7-10 WIND SPEEDS FROM 110 MPH TO 190 FOR B AND C EXPOSURE CAT. co PROJECT NUMBER: CH *ASCE 7-10 SEISMIC DESIGN CATEGORY E *ASCE 7-10 SNOW LOADS UP TO 120 PSF GROUND SNOW LOAD OP-00213236 _ *BUILDING WITH MEAN ROOF HEIGHTS UP TO 60 FOOT TILT ANGLES/ROOF PITCHES FROM 0 SYSTEM SIZE: __ _.._..... @) (E)1-STORY a - 0 � 1 DEGREES TO 60 DEGREES. 4.86 KW r- W j - THE ROOF MOUNTED PHOTOVOLTAIC SYSTEM IS UL 1703/2703 TESTED FOR SYSTEM FIRE RATING ~ -- - - N CLASS A WITH TYPE 1 MODULES (SNAP-N-RACK UL FILE E359313). SHEET TITLE: UL LAYOUT + N W MODULES SHALL BE INSTALLED WITH A MINIMUM 3 INCH CLEARANCE FROM ROOF SURFACE TO A" M N PANEL. CONNECTION U_ .. ..®..LIJ GV r.¢.:..z,:_:__:::e..=_:,__{_,,_.:PL �, - - ANUAL > . - TALLATIO eR TS. PLEASE REFER TO SNAP N RACK M )- DETAIL °uricio 7 PLNOTE. - _- - = _- _ N PROJECT BREAKD - SLI;Idin ®:� Rodriguez LICENSE BC10/C46/C39#941069 GV' ® AV ROOF MATERIAL: COMP MROORIGUEZQAMERICANSOL4RDIRECTCOM (626)435 —9221 PL _ HOUSE HEIGHT: ,:> y .r 1- STORY RACKING SYSTEM: SNAP N RACK (DGV . ROOF AREA: REVIEWED FOR CODE COMPLIANMSQ. FT. ---- - f L) TOTAL COVERED BY PHOTOVOLTAIC ARRAY: 11.33% TOTAL CRev,ewed By: 4j� �.�� POINT OF CONNECTIONS -e - O TOTAL CONDUIT WIRE LENGTH: 3 LN. FT. TO BE AT 6-0" MAX. -- ---- --Q Total # of Panels 18 City ReAsionlissue Date N Area Covered (Sq. Ft.) 318.42 o ® N W LL Avg. Load per Connection Point (Ibs) 26.30 Q?,OF ESS/oN c00 ��G TRUE q� THIS DRAWING IS PROPERTY OF AMERICAN S CONFIDENTIAL L AND IS DRAWING IS CONFIDENTLAL AND IS ONLY TO BE USED IN CONJUCTION Weight per sq. ft. of Solar Array (psf) 3.14 Total Weight of Modules 765.90 CO `]�Af �AG �v WITH WORK DESIGNATED BY AMERICAN SOLAR DIRECT INC. NO Total Weight of Racking Components 195.76 N N0. C70784 TOFTHZ DISCLOSEDI TO OTHERS WITHOUT THE PRIOR WRITTEN PERMISSION Total System Weight (lbs) 999.46 —I -- M D-1 EXP. 06/30/2017 rTl D OF AMERICAN SOLAR DIRECT INC. Total Rail Length (ftl 167 95 30'-10" 22'-9" Of 10' Snap N Rack Rails (122") ) CP >9% CIV )L P CAD Revisions # of 13' Snap N Rack Rails (162") 12 ER-CC-2/26/16 Total Rail Length Field (ft) 172.17 -- - — — OF CAS\F 53'-6" j� 02/29/2016 9 of Snap N Rack Rail Splices 5 Total # of End-Clamps 24 LAYOUT SCALE= NTS Total # of Mid-Clamps 24 tyle: =-_' heel PV2 Total#ofL-foot Da1a Assemblies 38 ABLE A: DC STRING CONFIGURATION EMPERATURE INFORMATION SUNEDISON SE -F270 KzD-3y SOLAR MODULES 32° C = 102" F- ASSUMED HIGHEST TEMPERATURE SE -F270 KzD-3y MODULES INCLUDE #12 AWG OUTDOOR RATED MC4 CONNECTORS FOR MODULE -7° C= 20° F- ASSUMED LOWEST TEMPERATURE SHORT MAXIMUM HIGH TEMPERATURE CORRECTION LOW TEMPERATURE CORRECTION HIGH CONDUIT CORRECTION NOTE: EXPOSED CONDUCTORS SHALL BE )INDUCTOR CONDUCTOR LOCATION NUMBER OF IRCUIT CURRENT NOMINAL CONDUCTOR CONDUCTOR FACTOR AT 65"C (150`F) THWN-2/USE-2 SUNLIGHT RESISTANT. ID SOURCE CIRCUITS MODULES IN Isc (A) Impp (A) VOLTAGE (DC) SIZE TYPE PER NEC 310.15(B)(2)(a) EXPOSED CONDUCTORS SHALL BE UNITS) SERIES @ OPT @ INV AT OPTIMIZER (AWG) 32 NEC 690.31(C) FASTENED TO MODULE FRAMES OR S1 MODULE TO JUNCTION BOX 18 9.30 A 13A 350V 10 (PV WIRE) USE -2 (#10 at 150`)40A x.58=23.2A RACKING FOR PROTECTION 8 SUPPORT. -0.16954 36.88 -7 -32 11.07% 0.11072 41.99 32 7 ALL CONDUIT TO BE 2 1/2" off the ROOF. 1.2 JUNCTION BOX TO INVERTER 18 9.30 A 13A 350V 10 THWN-2 (#10 at 150°)40A x.58=23.2) PER NEC 310.15(B)(2)(a) EMPERATURE INFORMATION SUNEDISON SE -F270 KzD-3y SOLAR MODULES 32° C = 102" F- ASSUMED HIGHEST TEMPERATURE SE -F270 KzD-3y MODULES INCLUDE #12 AWG OUTDOOR RATED MC4 CONNECTORS FOR MODULE -7° C= 20° F- ASSUMED LOWEST TEMPERATURE INTERCONNECTION. DO NOT REMOVE THE QUICK CONNECTS, OTHERWISE THE MODULE WARRANTY AND THE UL LISTING HIGH TEMPERATURE CORRECTION LOW TEMPERATURE CORRECTION HIGH CHANGE CORRECTION CORRECTION CORRECTED LOW CHANGE CORRECTION CORRECTION CORRECTED TEMP. IN TEMP. (%) (INDICATED OUTPUT TEMP. IN TEMP. (%) (INDICATED OUTPUT CC) CC) OTO UNITS) CC) (°C) SOLARM (P300) RATED DC INPUTPOWER - 300 WATTS, INPUTVOLTAGE - 8 TO 48 VDC, UNITS) MAXIMUM INPUT CURRENT - 12.5 ADC, MAXIMUM OUTPUT CURRENT - 15 ADC, STRING LIMITATIONS - 8 TO 25 32 7 -3.22 -8.69 261.31 -7 -32 14.72 0 270 32 7 -2.4% -0.16954 36.88 -7 -32 11.07% 0.11072 41.99 32 7 -0.168 -0.015792 9.42 -7 -32 0 77 0.768 9.4 2 r v-- (1) STRING OF (18) MODULES I I I I I O #6 GEC/EGC PER NEC L90.47.... T _--- -�-- 3/4" (EMT), (2) #10 THWN-2, (1)#6THWN-2 CONDUIT DERATE FACTOR ti Taor� I L1 4 (3) #10 THWN-2, 3/4" (EMT CC 1PH (2P) 240 VAC, 16A 16X125%=20.00A O PV SYSTEM DISCONNECT UTILITY OPERATIONS 30A L>1$SE &Q?_C2 R LC1944I_"--------- MODEL NO: SE380OA-US SE -F270 KzD-3y MODULES INCLUDE #12 AWG OUTDOOR RATED MC4 CONNECTORS FOR MODULE OSUNEDISON 1 INTERCONNECTION. DO NOT REMOVE THE QUICK CONNECTS, OTHERWISE THE MODULE WARRANTY AND THE UL LISTING 415OW WILL BE INVALIDATED. 240V IS PROVIDED TO MODULES AND OPTIMIZERS BY UL 2703 LISTED RACKING THAT PROVIDES OGROUNDING BONDING BETWEEN COMPONENTS. OPTIMIZERS ARE BONDED WITH STAR WASHER COttPLIANT TO UL 467. HOFFMAN NEMA 3R JUNCTION BOX MODEL: A6R64. USE WEATHERPROOF STRAIN RELIEF TO BRING (PV WIRE) OUSE-2/THWN-2 SOURCE CIRCUIT CONDUCTORS INTO THE JUNCTION BOX. TRANSITION TO THHN / THWN-2 CONDUCTORS IN JUNCTION BOX. USE TO PULL OUTPUT CIRCUIT CONDUCTORS TO SOLAR EDGE INVERTER SE3800A-US (240V) wILD SOLAREDGE INVERTER IS NEMA 3R RATED WITH UL 1741 LISTING INCLUDING INTERNAL ANTI-ISLANDING PROTECTION U) FEATURES. UL1741 LISTING INCLUDES COMPLIANCE WITH IEEE.519 FOR POWER QUALITY, IEEE.929 FOR W~ SAFETY AND THE NATIONAL ELECTRIC CODE. TIED TO EXISTING FACILITY GROUND. INVERTER OINTERCONNECTION HAS INTERNAL DC DISCONNECTION MEANS. INVERTER IS U.L. LISTED AS A UNIT. UNIT IS EQUIPPED WITH UL1741 UO APPROVED GROUND FAULT DETECTION DEVICE THAT MEETS NEC 250.122 REQUIREMENTS FOR EQUIPMENT m GROUNDING. NOTE: SEE ATTACHED CUTSHEETS FOR DETAILS. OTO PV SYSTEM DISCONNECT UTILITY OPERATIONS - TO BE PLACED BETWEEN INVERTER AC OUTPUT AND CONNECTION UTILITY TO COMPLY WITH NEC 690.61 AND LAEC 93.0207. TO BE A VISIBLE OPEN BLADE, LOCKABLE TYPE DISCONNECT LISTED FOR ITS USE. SOLARM (P300) RATED DC INPUTPOWER - 300 WATTS, INPUTVOLTAGE - 8 TO 48 VDC, MAXIMUM INPUT CURRENT - 12.5 ADC, MAXIMUM OUTPUT CURRENT - 15 ADC, STRING LIMITATIONS - 8 TO 25 OPTIMIZERS, 5250 WATTS STC PER STRING MAXIMUM (5250W / 15 ADC = 350 VDC) o PV CURRENT IS CALCULATED IN ACCORDANCE WITH ARTICLE 690.8 AND IS EQUAL TO 1.25'ISC = 1.25' 9.30 = OMAXIMUM 11.63 ADC. THE POWER OPTIMIZERS INCLUDE AN INTERNAL CURRENT LIMITING FUNCTION AND HAVE BEEN d- EVALUATED FOR CONTINUOUS OPERATION. THE MAXIMUM SUGGESTED MODULE ISC IS THEREFORE 10 AMPS. USE Q OF HIGHER CURRENT MODULES WILL NOT DAMAGE THE POWER OPTIMIZER BUT COULD RESULT IN REDUCED °° ENERGY YIELD DUE TO CURRENT LIMITING. (PER MANUFACTURERS INSTALLATION 690.7 (A)) O " PLEASE NOTE " SYSTEM VOLTAGE ADJUSTMENT FOR LISTED MODULES AND DEVICE ARE MADE IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS. (3) #10 THWN-2, 3/4" (EMT CC 1PH (2P) 240 VAC, 16A 16X125%=20.00A O PV SYSTEM DISCONNECT UTILITY OPERATIONS 30A L>1$SE &Q?_C2 R LC1944I_"--------- MODEL NO: SE380OA-US NOMINAL AC POWER 380OW MAX AC POWER 415OW OPERATING VOLTAGE 240V MAX OUTPUT CURRENT 16 AMPS P.V CIRCUIT BREAKER AIC RATING= 10kA MAIN SERVICE BUS RATING PER NEC 690.64, 705.12(D)(2) 100A x 120% = 120A TOTAL BUS LOAD= 120A!5 120A N 15A i5A EXISTING MAIN HOUSE PANEL 120/240V 103 WIRE SERVICE MAIN 100A BUS RATING DISTRIBUTION I UTILITY MAIN METERING SECTION BREAKER SECTION 100A L1 F___7, I I I I III I I I I I I I I I I I 50A I I SUB -PANEL 20A PV I L --------------- -I- EMSTNTI- FER,'SMWCE PANEL GROUND BUS AND/ Q VERIFIABLE Kit U 8 2 DUNDING ELECTRODE 1 1/4" (EMT) (3)#6AWGtRkj- VIEWED FOR CODE COMPLIANCE (1) #6 AWG THWN-2 GND Reviewed By: �. PROJECT DEVELOPER: n,,o American Solar Direct American Solar Direct Inc. LICENSE C10/C46 #941069 11756 WILSHIRE BLVD., SUITE 500 LOS ANGELES, CA 90025 PH: (424) 214-6700 FX: (424) 214-6750 http://w ..americansolardirect.com --e--------------------- 240V 1PH,2P (N) 100A SUB PANEL NON FUSED RELOCATE SQUARE D EXISTING LOAD MODEL: DU221 RB I I -Tr -Tr N 15A i5A EXISTING MAIN HOUSE PANEL 120/240V 103 WIRE SERVICE MAIN 100A BUS RATING DISTRIBUTION I UTILITY MAIN METERING SECTION BREAKER SECTION 100A L1 F___7, I I I I III I I I I I I I I I I I 50A I I SUB -PANEL 20A PV I L --------------- -I- EMSTNTI- FER,'SMWCE PANEL GROUND BUS AND/ Q VERIFIABLE Kit U 8 2 DUNDING ELECTRODE 1 1/4" (EMT) (3)#6AWGtRkj- VIEWED FOR CODE COMPLIANCE (1) #6 AWG THWN-2 GND Reviewed By: �. PROJECT DEVELOPER: n,,o American Solar Direct American Solar Direct Inc. LICENSE C10/C46 #941069 11756 WILSHIRE BLVD., SUITE 500 LOS ANGELES, CA 90025 PH: (424) 214-6700 FX: (424) 214-6750 http://w ..americansolardirect.com SYSTEM SIZE: 4.86 KW SHEET TITLE: SINGLE LINE DIAGRAM LICENSE C10/C46/C39 #941069 MRODRIGUEZQAMER ICANSOLARDIR ECT.COM (626) 435-9221 on, ­j I I Citv RevisioNlssue I Date I THIS DRAWING IS PROPERTY OF AMERICAN SOLAR DIRECT INC. THIS DRAWING IS CONFIDENTIAL AND IS ONLY TO BE USED IN CONJUCTION WITH WORK DESIGNATED BY AMERICAN SOLAR DIRECT INC. NO PART OF THIS DOCUMENT IS TO BE DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN PERMISSION OF AMERICAN SOLAR DIRECT INC. CAD Revisions ER -CC -2/26/16 E2 \w Uj Uj Wry (D d- :j 00 CN0') CO (v) wILD U U) rnrnZ W~ OJ UIQ UO m OW ��O�-OQ U) Z z U Q o o- O 2 Lu 0 -� d- a- Q °° U O PROJECT NUMBER: OP -00213236 SYSTEM SIZE: 4.86 KW SHEET TITLE: SINGLE LINE DIAGRAM LICENSE C10/C46/C39 #941069 MRODRIGUEZQAMER ICANSOLARDIR ECT.COM (626) 435-9221 on, ­j I I Citv RevisioNlssue I Date I THIS DRAWING IS PROPERTY OF AMERICAN SOLAR DIRECT INC. THIS DRAWING IS CONFIDENTIAL AND IS ONLY TO BE USED IN CONJUCTION WITH WORK DESIGNATED BY AMERICAN SOLAR DIRECT INC. NO PART OF THIS DOCUMENT IS TO BE DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN PERMISSION OF AMERICAN SOLAR DIRECT INC. CAD Revisions ER -CC -2/26/16 E2 SIGNAGE REQUIREMENTS TO COMPLY WITH NEC 2011 CODE ARTICLE 690 MARKINGS SHOULD BE AS FOLLOW: • RED BACKGROUND • WHITE LETTERING • MIN. 3/8" LETTER HEIGHT • ALL CAPITALS • ARIAL OR SIMILAR FONT • NON -BOLD (DURABLE ADHESIVE MATERIALS MUST MEET THIS REQUIREMENT) REFLECTIVE WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT THE PLAQUE WILL BE ATTACHED BY POP -RIVETS, SCREWS AND/OR OTHER APPROVED FASTENERS. (CEC 90.7, 110.3) ALL FEED AND PENETRATION TO BE FLASHED AND WATER PROOFED MARKINGS WILL BE PROVIDED IN ACCORDANCE WITH THE CAL -FIRE SOLAR PHOTOVOLTAIC INSTALLATION GUIDELINE. MATERIALS USED FOR MARKING MUST BE WEATHER RESISTANT. IT IS RECOMMENDED THAT UNDERWRITERS LABORATORIES MARKING AND LABELING SYSTEM 969 (UL 969) BE USED AS STANDARD TO DETERMINE WEATHER RATING. COMBINER BOX/CIRCUITS/ ENCLOSURES WARNING ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED. PER NEC 690.56(b)/690.35(F) EMT/ CONDUIT RACEWAYS CAUTION: SOLAR CIRCUIT PER NEC 690.31(E)(3) & IFC 605.11.1.2,605.11.1.4 DC DISCONNECT ON INVERTER DC DISCONNECT RATINGS: SE380OA-US OPERATING CURRENT: 16 A AC OPERATING VOLTAGE: 240 V AC MAXIMUM CURRENT: 32 A DC MAXIMUM VOLTAGE: 600 V DC UNGROUNDED PHOTOVOLTAIC SYSTEM PER NEC 690.5 (C) WARNING ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED. PV DISCONNECT/ BREAKER/POINTS OF CONNECTION PV DISCONNECT PER IFC 605.11.1, IFC 605.11.1.4, NEC 690.15 & NEC 690.14(C)(4) MAIN SERVICE DISCONNECT WARNING: MULTIPLE POWER SOURCES UTILITY POWER @ 240/120VAC, 100 AMPS PV POWER @ 240VAC, 20.00 AMPS PER NEC 705.12(D)(4), NEC 690.64 NEC 690.14(C)(4) CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED PER IFC 690.14(C)(2), IFC 605.11.1, NEC 605.11.1.4, NEC 690.15 & NEC 690.53 WARNING: PV DISCONNECT BACK FED BREAKER DO NOT RELOCATE PER NEC 705.12(D)(4), NEC 690.64 NEC 690.14(C)(4) CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN. SOLAR PHOTOVOLTAIC ARRAY ON ROOF - PV SERVICE POINT: DISCONNECT - INVERTER - UTkl"_ Iffw&wNF C - DC DISCONNECT PANELBOARD Reviewed SYSTEM BREAKDOWN MAIN PANEL AMPERAGE: 100A PV BREAKER AMPERAGE: 20A MAXIMUM AMPS OPERATING: 20.00A TOTAL PV AMPERAGE: 20.00A STRING: 1 NOMINAL OPERATING VOLTAGE: 240V OPTIMIZER OPERATING VOLTAGE: 350V NOMINAL OUTPUT CURRENT: 16A PER NEC 690.56 (B CUpE__ R's . IN 134ilding Departa 4 CODE COMPLIA V _ ' W-41 PROJECT DEVELOPER: American u Solar Direct American Solar Direct Inc. LICENSE C10/C46 #941069 11766 WILSHIRE BLVD., SUITE 500 LOS ANGELES, CA 90025 PH: (424) 214-67DO FX: (424) 214-6750 http://www.americansolardirect.com W J W w C p UQO wU u I- U) O m U U U) W v °6 O w Z 0� J Q 0 O 0o Q J O 07 PROJECT NUMBER: r__ O co 0 �NCn I Lo O (0 Co Lo o) rn Z Uo< d- Q OzU COQ w- a-0 ::) 2 U OP -00213236 SYSTEM SIZE: 4.86 KW SHEET TITLE: SIGNAGE Mauricio Rodriguez LICENSE C10/C46/C39 #941069 M ROD RIG UEZQAM ER ICAN SOLARD IRECT.COM (626) 435-9221 3 City Revision/Issue Date rTHIS DRAWING IS PROPERTY OF 4MERICAN SOLAR DIRECT INC. THIS DRAWING IS CONFIDENTIAL AND IS ONLY TO BE USED IN CONJUCT10N WITH WORK DESIGNATED BY AMERICAN SOLAR DIRECT INC. NO PART OF THIS DOCUMENT IS TO BE DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN PERMISSION OF AMERICAN SOLAR DIRECT INC. I CAD Revisions I E3 Series 100 Structural Report and Calculations Snap rack - Introduction This report describes. illustrates. and explains the Structural Calculation Packet for SuapNmck's Series 100 Mounting System, dated 4122012. The calculations have been performed in accordance with the 2012 International Building Cock (IBC). The racking system has been designed to withstand code -prescribed forces due to its own weight, the weight of the solar panels, the snow leads. and both to wind and seismic forces. Rall Spans This report coven two different material options for the system rails. Although they are both aluminum, one mil option uses a 6063 alloy (25 ksi yield) and the other Lues a 6005 alloy (35 ksi vi -k1). Despite having different yield strengths• both types of mils support the PV panels. As for the rails themselves, they ate supported by mounting hardware which attaches them to the roof structure with spans that arc expressed in inches. Rcfer to the tables below for rail spans under varying conditions of mil alloy and reef height. Shaded cells require an edge mne adjustment (see details following charts). Notes for Tables to thtu 2H I. Determine the mean roof heildlt, tilt angle, and mil alloy- (if you are unsure, use the 6063 alloy values). For mean roof heights less than 30 feet, use Table I A2A for tilt angles less than 19 degrees, Table IBt2B for tilt angles between 20 and 36 degrees. Table I C2C for tilt angles between 37 and 45 degrees, and Table t Dr2D for lilt angles between 46 and 60 degrees. For mean roof heights between 31 and 60 feet use Table (E2E for tilt angles less than 19 degrees, Table 1 F2F for tilt angles between 20 and 36 degrees, Table 1 G2G for tilt angles between 37 and 45 d arces, and Table 11112H for tilt angles between 46 and 60 degrees. 2. Determine the wind and snow load for the project site from the building dcparunonL Make certain to use 2012 IBC wind loads. Locate the wind load in the table across top rows and the snow load down the left columns to find corresponding maximum rail span. 3. For snow bads, column Pg equals the ground snow. 4. Shaded cells require application of an edge lone adjustment (details to fallow). NSSE 50.2 S.av A Bunk •sed Fan Oats CA 95625 (916) 536-9553 Rei. 125 n =013 NgC 5 Series 100 Snap rack - Structural Report and Calculations 1 .1 Rall •restine The aluminum rails have been dcsigno d in accordance with the 2010 Aluminum Design Manual (ADM) as referenced in the IBC. Testing was conducted per die standards sct forth by the IBC Seetiun 1715: I'mco struction Load Tess. The mulls of this testing procedure were used in comparison with the calculated values W euablish the tnaximutn uplift load allowed for the rai6. Raekdae Connections to the Existing Roof Contained within the calculation pocket arc calculations for the connection of ilio, rails to the roof framing. Using the sizes provided by SnapNrack. we have calculated the maxinntnr farces that will be resiocil based o1 the withdrawal value of the lag scrunm and the 5trcrigth of the aluminum components which are involved in trinstriing these fixtes from Ibe rail to die roof framing. These components consist of the flashed L -fixe (SnapNrack Dmvwing PEN-DOI), Standoff (PENT-DO2, D03), Seam Clamp (PL•NN-1304). Corrugated Block (PEN-DO5). Metal Rof`Busc (PEN-DO9, DID, DI 1, D12) and ikmgcr Bolt (PEN -1306). All (6) options ate wcq)mblc udder tit:. parameters shown in SnapYraci:'s plans. The results from our analysis have peen integrated into the summary charts. The cunncctiun of the PV racking systenn to the roof will Leve a 516^ diameter Lag Bolt installed widh a minimum 2 embedment into the framing member. Bolts shall be installed to a rafter ar bkNcking capable of supporting both wind and seismic lads abng with the might of the Pv system When PEN -D07 is involved, use minimum qucmfity 2 !%20 kilt bolts with innirmun l.25'• etnbxlmatt. In addition, SnapNmck's Tile Roof Hooks (Drawing PEN -DI 3, D14) arc also accxptabkattachment components when the following fitnimions nuc followed: 1. tilt roof hooks MNL beLai rcvicw•Ld up to 12o uhpli.Dien %VuW Spcvd 2- mil spun is limited to 6 feet with file roof h(uks \SNE --- 30225uai:eB:nulesad Fun Oohs GN95e:F(914n <tti )33S Ra•.[331-oo Pagc14 Snap rack - Solar Mounting Solutlons Series 100 Residential Roof Mount System The SnapNrack Series 100 Roof Mount System is an efficient, visually appealing, photovoltaic (PV) module installation system. Series 100 is listed to the UL 2703 for grounding/bonding and fire classification. The System provides an adequate bonding path which has eliminated the need for grounding lugs and washers at each module, and bonding jumpers between splices. In addition to grounding and bonding, the roof mount system, Series 100, is Class A Fire Rated when installed with Type I and Type 11 Modules. SnapNrack's UL 2703 Certification and Compliance ensures that SnapNrack installers can continue to provide the best in class installations in quality, safety and efficiency. • Appealing design with built-in aesthetics • No grounding lugs required for modules • All bonding hardware is fully integrated • Rail splices bond rails together, no rail jumpers required • Proprietary SnapNrack grounding lug snaps in the rail channel • No drilling of rail or reaching for other tools required • Class A Fire Rating for Type 1 and 2 modules System Features Include S.a In V-4—IWd Friby,Janay31,2014 Snap rack- Norman SnapNrack 775 Fico Lae, Cuire 200 Sao Luis Obispo, CA 93401 Iat."aa wM `series too RoofDlatur Casrr Letter wheel UL 2707 corbeled M..0—M To Whom h May Cozen, St Wehave performed calculations for the 100 seem roof me= PV system based on r u c t u r a 1 the information provided by SnapNrack. Included with this kucr are the report and accorda calculations. We did the oilouWions iw rce with the 2012 IBC, ASCE 7.10, "12 NDS, and Ruideiirea aimed in the Solr America Board for Codes and E n I a e e r Standards. R Some of the camponcrua o the SwpNrack tot dw wee used to determine the capacity and section properties of nacriols. We collected the test data using the 5@2Sraal.d. Far O.U. CA 9567! pmceduresomlimdindw20t21BCChairerl7. (91y 536.95/! 010,13"2100.1 We included the followint types of load combinations and building parameters into i9s9-mer our wkulatioas- a ASCE 7-10 wind speeds from 110 mph to 190 for B and C expatiate categories . ASCE 7-10 Seismic Daign Category E • ASCE 7-10 Sooty• bads up to 120 pat ground spew • Buildings with moa roof heights up to 60 foot dh sagla; roof pitdws Nrsaw Scheel. SE frac( 0 degree to 60 degrees. LEEAraD•r tf.ED Arts« The akvYtiont have also becri completed is socosdmnee with the 2006 BBC. 2009 rule,-seAcu r ao-Ase[ IDC, and ASCE 7-05. To use the dsla contained in this et for P Rgorts that arc r.�t nosuaass•• - ^ being cvaluaWd to the older ASCE 7.05 wind speeds, refs to Appeadia A fee a Rob Cana wind speed conversion chart. Find the ASCE 7-05 (IBC 20062009) wind speed is C. ,ea: htavOP the Chat is Appeodiv A, idemiiy the eonespondnLg ASL'E 7-10 (IDC 2012) wind r.ra: remmtseoasys speed value• and proceed with acing the charts contained in this packet with the Am Smkb F.6 adjusted wind speed value c..•a In our upioion, the mounting "can, autliaed by SnapNrack Series 100 PV Meustiag System Code Cmplisno: k-, Isdioa Manual, is axcplabk and mous Su es caatar-9 the loading requirements u bnvc. Set the report ansteed sd calculation included rADs, E.- —9 .pm G,i r� with this toner for more infomutioa Jaeue Miale If them ere any Rather questions, please contact Norm Scheel. 1 Orkr NNaea a a a►rt.rs9m �� `e• Norman Scheel PI3, SELEMAP a � SEAOC ®AF iM,os ' RIM AS� * � 17A1for J�1 �LtN� S JAN 31 2014 Series 100 Structural Report and Calculations Snap rack - Introduction This report describes. illustrates. and explains the Structural Calculation Packet for SuapNmck's Series 100 Mounting System, dated 4122012. The calculations have been performed in accordance with the 2012 International Building Cock (IBC). The racking system has been designed to withstand code -prescribed forces due to its own weight, the weight of the solar panels, the snow leads. and both to wind and seismic forces. Rall Spans This report coven two different material options for the system rails. Although they are both aluminum, one mil option uses a 6063 alloy (25 ksi yield) and the other Lues a 6005 alloy (35 ksi vi -k1). Despite having different yield strengths• both types of mils support the PV panels. As for the rails themselves, they ate supported by mounting hardware which attaches them to the roof structure with spans that arc expressed in inches. Rcfer to the tables below for rail spans under varying conditions of mil alloy and reef height. Shaded cells require an edge mne adjustment (see details following charts). Notes for Tables to thtu 2H I. Determine the mean roof heildlt, tilt angle, and mil alloy- (if you are unsure, use the 6063 alloy values). For mean roof heights less than 30 feet, use Table I A2A for tilt angles less than 19 degrees, Table IBt2B for tilt angles between 20 and 36 degrees. Table I C2C for tilt angles between 37 and 45 degrees, and Table t Dr2D for lilt angles between 46 and 60 degrees. For mean roof heights between 31 and 60 feet use Table (E2E for tilt angles less than 19 degrees, Table 1 F2F for tilt angles between 20 and 36 degrees, Table 1 G2G for tilt angles between 37 and 45 d arces, and Table 11112H for tilt angles between 46 and 60 degrees. 2. Determine the wind and snow load for the project site from the building dcparunonL Make certain to use 2012 IBC wind loads. Locate the wind load in the table across top rows and the snow load down the left columns to find corresponding maximum rail span. 3. For snow bads, column Pg equals the ground snow. 4. Shaded cells require application of an edge lone adjustment (details to fallow). NSSE 50.2 S.av A Bunk •sed Fan Oats CA 95625 (916) 536-9553 Rei. 125 n =013 NgC 5 Series 100 Snap rack - Structural Report and Calculations 1 .1 Rall •restine The aluminum rails have been dcsigno d in accordance with the 2010 Aluminum Design Manual (ADM) as referenced in the IBC. Testing was conducted per die standards sct forth by the IBC Seetiun 1715: I'mco struction Load Tess. The mulls of this testing procedure were used in comparison with the calculated values W euablish the tnaximutn uplift load allowed for the rai6. Raekdae Connections to the Existing Roof Contained within the calculation pocket arc calculations for the connection of ilio, rails to the roof framing. Using the sizes provided by SnapNrack. we have calculated the maxinntnr farces that will be resiocil based o1 the withdrawal value of the lag scrunm and the 5trcrigth of the aluminum components which are involved in trinstriing these fixtes from Ibe rail to die roof framing. These components consist of the flashed L -fixe (SnapNrack Dmvwing PEN-DOI), Standoff (PENT-DO2, D03), Seam Clamp (PL•NN-1304). Corrugated Block (PEN-DO5). Metal Rof`Busc (PEN-DO9, DID, DI 1, D12) and ikmgcr Bolt (PEN -1306). All (6) options ate wcq)mblc udder tit:. parameters shown in SnapYraci:'s plans. The results from our analysis have peen integrated into the summary charts. The cunncctiun of the PV racking systenn to the roof will Leve a 516^ diameter Lag Bolt installed widh a minimum 2 embedment into the framing member. Bolts shall be installed to a rafter ar bkNcking capable of supporting both wind and seismic lads abng with the might of the Pv system When PEN -D07 is involved, use minimum qucmfity 2 !%20 kilt bolts with innirmun l.25'• etnbxlmatt. In addition, SnapNmck's Tile Roof Hooks (Drawing PEN -DI 3, D14) arc also accxptabkattachment components when the following fitnimions nuc followed: 1. tilt roof hooks MNL beLai rcvicw•Ld up to 12o uhpli.Dien %VuW Spcvd 2- mil spun is limited to 6 feet with file roof h(uks \SNE --- 30225uai:eB:nulesad Fun Oohs GN95e:F(914n <tti )33S Ra•.[331-oo Pagc14 Snap rack - Solar Mounting Solutlons Series 100 Residential Roof Mount System The SnapNrack Series 100 Roof Mount System is an efficient, visually appealing, photovoltaic (PV) module installation system. Series 100 is listed to the UL 2703 for grounding/bonding and fire classification. The System provides an adequate bonding path which has eliminated the need for grounding lugs and washers at each module, and bonding jumpers between splices. In addition to grounding and bonding, the roof mount system, Series 100, is Class A Fire Rated when installed with Type I and Type 11 Modules. SnapNrack's UL 2703 Certification and Compliance ensures that SnapNrack installers can continue to provide the best in class installations in quality, safety and efficiency. • Appealing design with built-in aesthetics • No grounding lugs required for modules • All bonding hardware is fully integrated • Rail splices bond rails together, no rail jumpers required • Proprietary SnapNrack grounding lug snaps in the rail channel • No drilling of rail or reaching for other tools required • Class A Fire Rating for Type 1 and 2 modules System Features Include S.a In V-4—IWd SInal. T-1 batall i.. Fa.yNe L.—fi a cuts., rOriake sr Iat."aa wM Pr eared lncvgaNdba.aing UL 2707 corbeled M..0—M harder. Resources snapnrack.eom/resources Design confgure.snapnrackcom Wheretolluirsnaprirack.com/buy Series 100 Snap rack- Snap rack - Solar Mounting Solutions Structural Report and Calculations Rail Testirw The aluminum rails have been designed in accordance with the 2010 Aluminum Design Manual (ADM) w referenced in die iBC. Testing was conducted per the standards sea forth by the IBC Section 1715; Ptecwstruction Load Test. The results of this testing procedure were used in comporison with the calculated values to establish the maximum uplift load allowed for the rails. Raddne Connections to file Existing Roof Contained within the calculation packet arc calculations for the connection of the rails to the roof framing. Using the si7.es provided by SnapNrack, we have calculated the maximum forces that will be resisted based on the withdrawal value of the lag screws• and the strength of the aluminum components which are involved in transferring Uvese forces from the rail to the wor framing. These components consist of the flashed L -foot (SnapNrack Drawing PEN -DO 1), Standoff (PEN-DO2. D03), Seam Clamp (PEN -1304), Corrugated Block (PEN -DOS). Metal RDof Base (PEN-DO9, DiD. DI 1, D12) and Ilautber Bolt (PEN-DO6). All (6) options are acceptable under the parameters shown in SnapNrack's plans. The results fmm our analysis have been integrated into the summary charts. The connection of the PV racking system to the roof will use a 5116' diameter Lag Bolt installed with a minimum 2 'A" embedment into the framing member. Bolts shall be installed to a rafter kr blocking capable of suppkrting both wind mixt seismic loods along with the weight of the PV system. 'When PEN -D07 is involved, use minimum quantity 2 ;-20 lag bolts with minimum 1.25" embedment. In addition, Snap\rack's Tile Roof Hooks (Drawing PEN -D 13, D14) arc also acceptable attachment components when the following limitations are followed: I. the roof hooks have been mview'cd up to 120 mph, Design Wind Speed 2. rail span is limited to 6 feet with file roof hooks NSSE '02_' Suriw Book want Fair Ones CA 956'25 (916) 5369555 Roti. 1271 _ :i Pagc 14 :,+.=..e w:.'.•. w.•w.sr sage wn --- --- a..i'wu"r'.�w' . s.,,.nsr arty +r.aw.. e..... w••«. a..ra.a ar+e ae�.a.nawn c.strrar errM w<I�. aaaaralsr guar s••ra�•a— " I—*., wo. w.. sw.I" au*m., _ A•...rw N,eawaaa>elrMwar Iraeeaa) — 0r ,„. — Y•a,YN err.. / We.Mrw. C4A ..r� a...n .� AlliY s..rw.e /.ray a..rar,ra. w..aru s,rrrr k wr aaa rw n9raws ...e... CUPERTINO f3u;llding Depertmertt 4 20,116 Ra VIE ED FOR COLE COMPLIANCE ReVIEMed By 4%A_� - °. 1000 Ser4a al4nrrNan - IUIuwYM • suinlae rtaal . -..:. • q herd steeland alarli um floshi p • Clem and black anodized aluminum PW*rlal Finish • Mill finish on sNect products NaM. aro. m:rerv. a.om.cn mal �+r ..e onions. wr n.... . W d.to OLStara ad 2103 he Gaoiaidi+gAoralne and nae C' ImmVisa- don (;ass.4 C"neal"o" • t]. A rhe gaup TAW t,airiNPi 2 gpob!w - Ra_nWd Struc_4ral �aporta,lor_Y15C Stdn • SnapNrack Grounding Lug (Orbe lug per individual row of modules) Wounding -Integrated bonding wrnanep 10 pear owned is or Wwr rW,, S Your Inait tetsh warionly 877-732-2860 www.snapnrack.com contactCwsriaprtrack com solar =@@ SolarEdge Single Phase Inverte For North America SE3000A-US / SE380OA-US / SE5000A-US / SE6000P SE760OA-US / SE1000OA-US / SF1140OA-US 0 4 The best choice for SolarEdge enabled systems Integrated arc fault protection (Type 1) for NEC 2011 690.11 compliance Superior efficiency (98%) Small, lightweight and easy to install on provided bracket Built-in module -level monitoring Internet connection through Ethernet or Wireless Outdoor and indoor installation Fixed voltage inverter, DC/AC conversion only Pre -assembled Safety Switch for faster installation Optional - revenue grade data, ANSI C12.1 USA -GERMANY - ITALY- FRANCE -JAPAN -CHINA -AUSTRALIA -THE NETHER LAN D5 - ISRAEL WWW.solaredge.us solar=@@Single Phase Inverters for North America SE3000A-US / SE380OA-US / SE5000A-US / SE6000A-US / SE760OA-US / SE1000OA-US / SE1140OA-US SE3000A-US SE3800A-US I SESOOOA-US I SE6000A-US I SE7600A-US SE10000A-US SE11400A-US OUTPUT Nominal AC Power Output 3000 3800 5000 60007600 9980 @ 208V I 11400 VA 14000. 240V Max. AC Power Output 3300 4150 5400 @ 208V 6000 8350 10800 @ 208V 12000 VA .................................. 5450 @240V ............ 10950 @240V . . AC Output Voltage Min. -Nom: Max 1�1 _ 183. 208 :229 Vac............ .......... , ........ ..... . ... ............ ........ AC Output Voltage Min. Nom; Max!t( J 211- 240 - 264 Vac AC Frequency Min -Nam: Max.1i1 59.3 - 60 - 60.5 (with Hl country setting 57 :60 - 60.5) Hz Max. Continuous Output Current 12.5 16 @ I 32 @ 208V 47.5 A :.........: l :24.?1.@ 208V ?40� 25 : f ::.........: f :. 42 ................. . GFDI Threshold ..... ...... Utility Monitoring, Islanding Protection, CountryConfigurable Thresholds Yes Yes INPUT Maximum DCPower(STC) 4050 5100 6750 8100 10250 13500 15350 W T2nsformer-less, Ungrounded ......................................... Yes ................................ , .......... ... Max; Input Voltage. .......................................... . 500 Vdc Nom. DC Input Voltage 325 @ 208V / 350 @ 240V ... , ... Vdc Max. Input Current(" 9.5 13 16.5 @ 208V 1 33 @ 208V l ........... I........... 1. 15:5 240V .I.....1S I.....23..... I. 30.5.x° 240V..1.....345 ... Adc ... Max.................. (rent ,,,,,,.......... •,,,,,,,,,,,,,,,,,.............I............. ........ Input Circuit 45 Adc Reverse -Polarity Protection .................................................. Yes Ground -Fault Isolation Detection 6 611 Sensitivity . Maximum Inverter Efficiency 97.7 98.2 1 98.3 . .. 98.3 98.... 98.... 98..... % 97.5 @ 208V . i .. 97 @ 208V . CEC Weighted Efficiency 97.5 98 ! 97.5 97.5 97.5 % 1.. gH........... 97.5.�.240V............. . Nighttime Power Consumption < 2.5 <4 W ADDITIONAL FEATURES Supported Communication Interfaces 115485, RS232, Ethernet, ZigBee (optional) ......................................................................................................-..... ......... Revenue Grade Data, ANSI C12.1 Optional(" ......... ................... Rapid Shutdown - NEC 2014 690.12 _ Functionality enabled when SolarEdge rapid shutdown kit is installed"' STANDARD COMPLIANCE Safety UL1741 UL1699B, UL1998 , CSA 22.2 Grid Connection StandardsIEEE1547 .......... ... ......... I ................. ...... ........................ I .......... I.............. ......... ......... Emissions I FCC part15 class B INSTALLATION SPECIFICATIONS AC output conduit size / AWG range 3/4" minimum/ 16-6 AWG _ 3/4" minimum/ 8-3 AWG - DC input conduit size / # of strings / 3/4 minimum / 1-2 strings/ 16-6 AWG 3/4 grinimum /,��, rings / 14-6 AWG AWG range . ! X`, %. -. ......... .... . �. r T. �► Dimensions with Safety Switch 30.5 x 12.5 x 7/ I 30.5 x 12.5 x 7S / i In11_ g 6 I ti Q (HxWxD 30. �1 775 x 315 x 260 - .................. I ........... 775. 315 x• 172 ..... ...... 775. x 315 x.191...... ..........� .-f.. ..............iiu i r • ! 1 n Wei ht with Safe Switch 51.2/23.2 54.7 / 24) ' d")40.1 • I l apartment Cooling .. Natural Convection a laceable) dBANoise................................ 2..... a ............................. Min: Max. Operating Temperature -13 to +140 / -25 to +60 (-40 to +60 version available(sl) -F/ -C Range'...: :.......................................... • NEMA 3.1.1 ......... C/i�V�/p"�o.k:G�7D l.lA'uVC� Protection Rating ......I ................. ..... COMP i" For other regional settings please contact SolarEdge support nQ ' A highercurrem source may be used; will limit its input current to the values stated. Revi_-VYeo By. mRevenue grade inverter P/N: 5E=ouk-USMNNR2 " Repid shutdown kit P/N: SE10004iSD-S1 -40 version PIN: SEaxxxA-U5000NNU4 solar, =ee ;. SolarEdgePower Optimizer " ri I Add -On f North America V U r, V1 V P300 / P350 P400 / P405 P300 P3SOF P40S [for 60 -cel modules) (for 72-c6l modules) t'.r w thin film modules) INPUT Rated Input DC Powerl") 300 350 400 405 W . ........ . ......... * ..... ...... . . Absolute Maximum Input Voltage 48 60 80 125 Vdc (Voc at lowest temperature) ........ ................. ........... I........... . ..................................... .... MPPT Operating Range 8-48 8-60 B-80 12.5-105 Vdc ......................... Maximum Short Circuit Current (Isc) 10 Adc . . . * --- * .............................. ............................................. ..... .......... Maximum DC Input Current 12.5 Adc ...................... ............................. . ... ....................... .. .......... I .......... Maximum Efficiency 99.5% ...................................................... .... . I ........ ....... . . . . . . . . . . . . . Weighted Efficiency98.8 % ........... I ................. ............ I ....... I ............................. ...... Overvoltage Category T 11 OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) Maximum Output Current1 15 d .......................... ... .......... ....... ............. . I ......... A.c. . Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE EMC FCC PartlS Class B, IEC61000-6-2, IEC61000-6-3 ..................... Safety I EC62109-1 (class 11 safety), UL1741 ............. ................ .. ......... ............... .................. ..................... RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc: .......................... ..... * .......... *'"* ........ .... .. ........ Dimensions (W x L x H) 141 x 212 x 40.5 / 5.55 x 9.34 x 1.59 mm/in .......... ........ - .... . ... I ....... ..... ................................. ............. . . ....... Weight (including cables) 950/2.1 gr / lb MC4 /A'm­phe'n'o*I /'T'y'c'o­ ....... ........................ Input Connector MC4 .......................... .............. ......... .................. ..................... . Output Wire Type / Connector Double Insulated; Amphenol .. ........... .... Output Wire Length 0 .95/3. 0 1.2 3.9 m ft ......................... . .............. ... ................. I .... .................. Operating Temperature Range -40 - +85 / -40 - +185 'C C/ -F .......... I....... ............... ...... ........... ....... Protection RatingI P65 NEMA4 ................ .............. ..... . ................. ...... ............... Relative Humidity 0.-.1.0.0 Rated STC power of the module. Module of up to +5% power tolerance allowed. PV SYSTEM DESIGN USING A SOLAREDGE INVERTER(2) SINGLE PHASE THREE PHASE 208V THREE PHASE 480V Minimum String Length 1.655 rrdnx 9% rnrn x 50 mm NGW* -ftight (Power Optimizers) ......I ................. .. 10 18 .............. ........ ............ .................... I ........ Maximum String Length 66 -7-7-- lFiniiiiisoMYIlxial (Power Optimizers) ............. I ....... 25 25 50 ...... ....... ......................... ...... Maximum Power per String .................... ............ 52SO 6000...... 12750 ..................... .. ........ I ....... .............. I ...... W ........ Parallel Strings of Different Lengths -0-43 olf.X or Orientations Yes - 0.06 "I&K: ............. It isnot allowed to mix P405 with P300JP350/P400/P60Q/P700 in ....... ......................... .. ........I.......... me string. Maximum System SunEdison SILVANTIS F -SERIES: 255W TO 275W PKYSICAL PARAMETIFFS MG&Ae Dionioritsilants 1.655 rrdnx 9% rnrn x 50 mm NGW* -ftight 19-3 kg OCIRrIn cor-tanuous Cz (CC -rt monoc-losuffim Numllw of CeNs 66 -7-7-- lFiniiiiisoMYIlxial Artwfizt:unwwrrt - �All Tempered ARC Glass Tii�ies 1 32 mm TEMPEMIURE COEFFICIENTS AND PARAMETERS' 1 375 376 57 7 37-B 37.9 375 376 37.7 45C - 2C Tertnpetatttre Coefficient of P. -0-43 olf.X -0 34 %JC ci Temperatum Covffier4 or Isc - 0.06 "I&K: Opwaliliv Teimperature -AGC to 095C Maximum System 1000V - JUL . Ill IEC) LirrifimS Roww" Currwd 9"A Maximum Series Fuse Raing JG A PWw Production Tolman. owtv-&SW Junction Box P.-Aing IP67 MC 6173D Appficallion Cies A Module Fir- Performance mance T) Module Fwv On" C NOCT ELECTRICAL CHARACTERISTICS' racloWng hp6t9ttabons j 5 perpallet (e.% F2xxCzD-2VY 1 CO QD QD CzD CrD KZ3 KzD KzD Rated blaxirrium IE617 1cI541 T93.0 196.6 i 200.3 154.1 187.7 191.3 520 modYes Per4U hk;h-cube container tubed and Snow From LoadUp to 5,403 Pa Wirld flack Load 2.400 Pa Fliaduclioin of Sm efficiency from low WNW < 4% S7C ELECTRICAL CHAIRAMFISTI�S' Utbil - ­7F-26�- Figk' V26 -F:i"- F26D F265 F7M FM (-io F2xxCzDL-NP C!D CzD CzD CzD CzD Kz3 K20 KzD KzD KzD RatedlA�tinttm j 2'5 26+0 265 270 275 255 260 265 270 275 POYM IMax rM c1houtGer, Ma E 0pwA3nzAVdbp 1 375 376 57 7 37-B 37.9 375 376 37.7 378 37 9 Vat: M st'"t-amuit curtem w-- 0 S35 9.40 9.45 i 916 9.20 925 930 9�35 Isc IN Molle Eficiioniq 1%) ISS ISS 161 Will, i I&S 156 1 15.8 16.1 164 16.8 4"-';�U-m 0uwW- �Pohl[ 28.9 30.0 30.1 30.2 1 303 299 1 300 30.1 30.2 30.3 vah3sm virrill M -i aiS' IDD Moadir in Rarer Pdk 853 867 9S1 894 T -K-67 844 ias C'urtl-A �BFF' V4 NOCT ELECTRICAL CHARACTERISTICS' Madel ! PAS F260 FM F270 F775 FnS F260 FM F270 F275 (e.% F2xxCzD-2VY 1 CO QD QD CzD CrD KZ3 KzD KzD Rated blaxirrium IE617 1cI541 T93.0 196.6 i 200.3 154.1 187.7 191.3 KZD 194.9 KzD 196-5 I I I - 4 -iW-7 -ji-- 8 349 -Powe,rPmax(" - Opw.0milit Voltage X 7 5i -9-34.8-34-9 3199 346 31-7 OpIV) 7.41 7.01 Short-Grc:OK CurijW--- 72 7.55 TE 7-32 7.35 7.33 lac W -ii -5 Mmirniumpawat Poirit r.4 27.5 -7 5 27.6 27 6 -2?-T.--i7-4 2-7-5 276 %Mabets Vff"P M Maxirnumll'amwPoirt 1 9,18 ago 7.02 7 -14 17.26 6.7 6.97 709 7.21 kvw 1A) F- SERIES SOLAR MODULE DIMENSIONS onrin finehl see"" AA Malde Dir"nas6ris A - 990 139.Gi .3 - 1.658165.3„1 C - 50 12 01 D-3-011 lal Mounting Halo Spacing E - 950137A I F - 994 139. 11 C" Lowh 'L - :.000151 21 Junction Box Dimensions 101.5 >; C-0.0 X 25 5 [190 X 2.30)1101 L - Other opeoas avia4aWe upon request; please contact your local saes f0pro-sentaylve for more 0??10!tM6o?t- FV CURVES AT MULTIPLE IRRADIANCES [2S C1 GO 5 N CURVES 0 Usted specifications are subject to change without prior notice. 'Tairnpmrurre coeffixlerm may i-ary by llarlbV =S%andpowee nwasremenitokawce by =3% PM. -X Produca" Tawancel• fr tory rneestnrzcl module varrWrlawe i; wamented to Mew or emceed ft 'zMW Panel`57C powpir r d&Vbyo Wro +5W • Y Indcatw connectcv tvpe: = 8-** S4r8.-38 = Aqptmnd)---basu4 z -idvatuo; manutKtarmg ja,-woa - M - Mqlaywd, X - Afmoo M6�--" -q7 =n64 -ons orce& WO W ed VICAW rWrM,61 00--rdt ffn;, 20 C AM 1 :5, wind i rr.4 For mor* itntornnabon abut SunEdison's Silvantis modules, please visit wraw-suinedison,ram ;� 2014 S-,Zrbse,, Ptta,.Is �-133p-e :'4x- LIJ. t- S -Edi -on U -P * Aul T-Iht:- L096 e fagi:t-'(-'ed oe s-;jon�ia*s of Sr c t s n Proauvn SmgmDtc Pto Lid anCl,-! its UftW!55 V1 lt'.E) UrLit-Od ft4105 and Certain in th 5 A,;.t ttia m4ap rtv rf ov:r. r7 CRINNO i Depp-rtMenf W/MJ MPLIANCE INC 191 9 LG3 VC98 116 D", 50mm VI 1 12 201 A warn a� JPLAIM c1houtGer, Ma E r *A011LILE LAIML�p see"" AA Malde Dir"nas6ris A - 990 139.Gi .3 - 1.658165.3„1 C - 50 12 01 D-3-011 lal Mounting Halo Spacing E - 950137A I F - 994 139. 11 C" Lowh 'L - :.000151 21 Junction Box Dimensions 101.5 >; C-0.0 X 25 5 [190 X 2.30)1101 L - Other opeoas avia4aWe upon request; please contact your local saes f0pro-sentaylve for more 0??10!tM6o?t- FV CURVES AT MULTIPLE IRRADIANCES [2S C1 GO 5 N CURVES 0 Usted specifications are subject to change without prior notice. 'Tairnpmrurre coeffixlerm may i-ary by llarlbV =S%andpowee nwasremenitokawce by =3% PM. -X Produca" Tawancel• fr tory rneestnrzcl module varrWrlawe i; wamented to Mew or emceed ft 'zMW Panel`57C powpir r d&Vbyo Wro +5W • Y Indcatw connectcv tvpe: = 8-** S4r8.-38 = Aqptmnd)---basu4 z -idvatuo; manutKtarmg ja,-woa - M - Mqlaywd, X - Afmoo M6�--" -q7 =n64 -ons orce& WO W ed VICAW rWrM,61 00--rdt ffn;, 20 C AM 1 :5, wind i rr.4 For mor* itntornnabon abut SunEdison's Silvantis modules, please visit wraw-suinedison,ram ;� 2014 S-,Zrbse,, Ptta,.Is �-133p-e :'4x- LIJ. t- S -Edi -on U -P * Aul T-Iht:- L096 e fagi:t-'(-'ed oe s-;jon�ia*s of Sr c t s n Proauvn SmgmDtc Pto Lid anCl,-! its UftW!55 V1 lt'.E) UrLit-Od ft4105 and Certain in th 5 A,;.t ttia m4ap rtv rf ov:r. r7 CRINNO i Depp-rtMenf W/MJ MPLIANCE INC 191 9 LG3 VC98 116 D", 50mm VI 1 12 201 A SOLAR EDGE POWER OPTIMIZER 5/160 SS BOLT WITH SS FENDER WASHER SOLAR EDGE OPTIMIZER MOUNTING BRACKET WITH INTEGRADED GROUND CERTIFICATE OF COMPLIANCE Certificate Number 20140204-E359313 Report Reference E359313-20140201 Issue Date 2014 -FEBRUARY -04 Issued to: SNAPNRACK STE 200 775 FIERO LANE SAN LUIS OBISPO CA 93401 This is to certify that MOUNTING SYSTEMS, MOUNTING DEVICES, representative samples of CLAMPING DEVICES AND GROUND LUGS FOR USE WITH PHOTOVOLTAIC MODULES AND PANELS USL—Series 1D0 Mounting and Bonding Systems for use with Photovoltaic Modules Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standards) for safety: UL Subject 2703 -the Outline of Investigation for Mounting Systems, Mounting Devices, Clamping/Retention Devices, And Ground Lugs for use with Flat -Plate Photovoltaic Modules and Panels Additional Information: See the UL Online Certifications Directory at uvwAr.ul.ccrrVdak3base for additional information Only those products bearing the UL Listing Mark should be conslderod as being covered by UL's Listing and Follow -Up Service. The UL Listing Mark generally includes the following elements: the symbol UL in a circle: © with the word 'LISTED*, a control number (may be alphanumeric) assigned by UL; and the product category name (product identifier) as indicated in the appropriate UL Directory. Look for the UL Listing Mark on the product. Page 1 of 1 STAR WASHER SNAP N RACK BONDING CHANNEL __=LJUUUUUU NUT 5/160 S.S. BOLT WITH S.S. FENDER WASHER 6 AWG (GEC) SNAP N RACK SERIES 100 RAIL MODEL # 242-02101 UL LISTED snap n rack GROUND LUG GROUNDING DETAIL (SIDE VIEW) SOLAR MODULE SNAP N RACK MID CLAMP MODEL # 242-02054 UL LISTED MID CLAMP star washer SNAP N RACK BONDING CHANNEL NUT solar- s 1 -- architectsofenergy- Grounding SolarEdge Power Optimizers PV Systems with module4evel electronics (DC -DC power optimizers or micro -inverters) Introduce another PV system component which must be grounded to meet NEC' requirements. This paper outlines the differing requirements, provides guidelines on how to properly ground SolarEdge power optimizers and supplies a list of racking models and their appropriate grounding method. There are two types of grounding connections used in PV systems. 1) Equipment grounding— Equipment grounding is required for all electrical devices with exposed metal surfaces, as outlined in 690.43-690.46 and, by reference, Table 250.122. Methods for equipment grounding of SolarEdge power optimizers are detailed in the examples below. 2) Grounding Electrode Conductor / System Bonding Jumper— not required in SOIarEdge systems. In a system utilizing a grounded array the Grounding Electrode Conductor is required by NEC 690.47-690.48 and 250.168. This conductor provides the bonding between the grounding system and one of the PV circuit conductors (PV negative or PV positive), and is required to be contiguous or irreversibly spliced. SolarEdge systems utilize ungrounded PV arrays as permitted under Article 690.35. When properly installed SolarEdge systems meet the requirements of 69035, and therefore no Grounding Electrode Conductor/System Bonding Jumper is required - Equipment grounding of SolarEdge power optimizers (for full details refer to the SolarEdge Installation Guide): When mounting on a grounded metal structure: Use the S/16" stainless steel grounding star washer (provided with the power optimizer) between the railing and the flat side of the optimizer mounting bracket. The star washer is approved as a Listed grounding means in accordance with the requirements of NEC Article 690.43(C). The stainless steel star washer is Listed for attachment of the power optimizer to galvanized steel, stainless steel and anodized aluminum structures. The stainless steel grounding washer penetrates the galvanized or anodized coating of the structure to ensure a low-resistance connection. Apply torque of 9.5 Nem / 7 Ib'ft. For mounting on rails with sliding nut fasteners or non-metallic structures: A separate equipment grounding conductor is required for power optimizers mounted on non-metallic structures and structures utilizing sliding nut fasteners (unless specifically Listed as a grounding means). Older SolarEdge power optimizers were supplied with a grounding lug for this purpose. Power optimizers currently in production are supplied without the optional lugs, but lugs may be purchased in bulk from SolarEdge (part number SE-GNDLUG-100). The grounding lug kit consists of four parts, all made of stainless steel to prevent corrosion of the copper grounding conductor and of the aluminum housing of the power optimizer. The grounding terminal will accept a wire size of 6-14 AWG and must be sized for equipment in accordance with NEC Table 25D.122. After connecting the lug to the power optimizer, connect an equipment -grounding conductor to the grounding terminal. Tighten the screws connecting the power optimizer to the rack and the grounding terminal screw with a torque of 9.5 N•m / 7 Ib`ft. • All Code references are to NFPA 70, NEC 2011 Edition SolarEdge Technologies I www.solaredge.us USA 3347 Gateway Boulevard, Tremont, CA, 94538 Germany Bretonischer Ring 18, 85630 Grasbrunn (Munich) Italy VISMUNDA SRI, Corso Del Popolo 50/A, Treviso Japan B-9 Ariake Frontier Building, 3-7-26 Ariake, Koto-Ku. Tokyo 135-0063 Israel 6 HeHarash St. P.O.Box 7349, Neve Neeman, Hod Hasharon 45240 China City Center, 100 Zunyi Road, Building A, Unit 1204, Shanghai 200051 SNAP N RACK X -END CLAMP MODEL # 242-02067 UL LISTED END CLAMP SNAP N RACK-' SNAP N RACK -/SOLAR EDGE GROUND LUG SERIES 100 RAIL OPTIMIZER 5/160 S.S. BOLT W/ S.S. FENDER WASHER GROUNDING DETAIL (FRONT VIEW) SNAP N RACK X -END CLAMP MODEL # 242-02067 SOLAR MODULE UL LISTED END CLAMP _ _ INO PER ft:lding Department 1 STAR WASHER " ' i -- >.11-� r r 4R08 FOR GROUNDING OPTIMIZERONLY REVIEWED DE COMPLIANCE SOLAR EDGE—/Reviewed Bye > OPTIMIZER GROUNDING DETAIL WITH END CLAMP (SIDE VIEW) 6 AWG CU GEC 6 AWG MODEL # 242-02101 CU GEC UL LISTED snap n rack MODEL # 242-02101 SNAP N RAC GROUND LUG UL LISTED GROUND LUG SERIES 100 RAIL 5/160 S.S. BOLT W/ S.S. FENDER WASHER GROUNDING DETAIL WITH END CLAMP (SIDE VIEW) SnapNrack UL 2703 Fire Classification: Attachment 1 of 1 HiS-MxxxMG Series - HiS-M210MG, HiS-M213MG, HiS-M215MG, HiS-M218MG, HiS-M220MG, HiS-M223MG, HiS-M225MG, HiS- M228MG, HiS-M230MG, HiS-M233MG, HiS-M235MG, HiS-M238MG, HiS-M240MG, HiS-M243MG, HiS-M245MG, HiS-M248MG, HiS- M250MG, HIS-M253MG, HiS-M255MG, HiS-M258MG, HiS-M260MG, HiS-M263MG, HIS-M265MG, HiS-M268MG, HiS-M270MG; HiS-SxxxMG Series - HiS-S220MG, HiS-5223MG, His-S225MG, HiS-S228MG, HiS-S230MG, HiS-S233MG, HiS-S235MG, HiS- S238MG, HiS-S240MG, HiS-5243MG, HiS-5245MG, HiS-S248MG, HiS-S250MG, HiS-S253MG, HiS-S255MG, HiS-S258MG, HiS- S260MG, HiS-S263MG, HiS-S265MG, HiS-S268MG, HiS-S270MG, HiS-5273MG, HiS-S275MG; all may be followed by the suffix BK or blank. Renesola Jiangsu Ltd: JCxxxM-24/BB Series - JC200M-24/Bb, JC205M-24/Bb, JC210M-24/13b, JC215M-24/Bb, JC220M-24/13b, JC225M-24/Bb, JC230M-24/Bb, JC235M-24/Bb, JC240M-24/13b, 3C245M-24/Bb, JC250M-24/Bb, JC255M-24/Bb, JC260M-24/Bb, Series And N JC265M-24/Bb, JC270M-24/Bb. 100 Suniva Inc - MVX-235-60-5-701, MVX-240-60-5-701, MVX-245-60- 5-701, MVX-250-60-5-701, MVX-255-60-5-701, MVX-260-60-5-701, MVX-265-60-5-701; MVX-235-60-5 7B1, MVX-240-60-5-7131, MVX-245-60-5-7131, MVX- 250-60-5-7B1, MVX-255-60-5-7131, MVX-260-60-5-7131, MVX-265- 60-5-7B1; OPT -250-60-4-800, OPT -255-60-4-800, OPT -260-60-4-800, OPT - 265 -60-4-800, OPT -270-60-4-800, OPT -275-60-4-800; OPT -250-60-4-880, OPT -255-60-4-8130, OPT -260-60-4-8B0, OPT - 265 -60-4-880, OPT -270-60-4-860, OPT -275-60-4-880. Yingli Energy (China) Co Ltd - YLXXXP-29b Series - YL215P-29b, YL220P-29b, YL225P-29b, YL230P-29b, YL235P-29b, YL240P-29b, YL245P-29b, YL250P-29b, YL255P-29b, YL260P-29b; YLXXXA-29b Series- YL220A-29b, YL225A-29b, YL230A-29b, YL235A-29b, YL240A-29b, YL245A-29b, YL250A-29b, YL255A-29b. ©2015 UL LLC When the UL Leaf Mark is on the product, or when the word "Environment" is Included in the UL Mark, please search the UL Environment database for additional information regarding this product's certification. The appearance of a company's name or product In this database does not in itself assure that products so Identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow -Up Service. Always look for the Maris on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non - misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2015 UL LLC". ,�` .� a r I /�'� Ulr 1 iNO o, v it9� Bding Dn-P21't-rent if 'qAR 2016 REVIEWED FOR C;)uE COMPLIANCE: Reviewed fay Trina Solar Ltd - TSM-215PA05, TSM-220PA05, TSM-225PA05, TSM- - 230PA05, TSM-235PA05, TSM-240PA05, TSM-245PA05, TSM- 250PA05, TSM-255PA05, TSM-260PA05; TSM-215PA05.05, TSM-220PA05.05, TSM-225PA05.05, TSM- 230PA05.05, TSM-235PA05.05, TSM-240PA05.05, TSM-245PA05.05, QIMS.E359313 TSM-250PA05.05, TSM-255PA05.05, TSM-260PA05.05; Mounting Systems, Mounting Devices, Clamping Devices and Ground Lugs for TSM-215PA05.08, TSM-220PA05.08, TSM-225PA05.08, TSM - Series And N 230PA05.08, TSM-235PA05.08, TSM-240PA05.08, TSM-245PA05.08, Use with Photovoltaic Modules and Panels 200 TSM-250PA05.08, TSM-255PA05.08, TSM-260PA05.08; TSM-215PD05, TSM-220PD05, TSM-225PD05, TSM-230PD05, TSM - 235PD05, TSM-240PD05, TSM-245PD05, TSM-250PD05, TSM- Page Bottom 255PD05, TSM-260PD05; ---- - _. _ _ _----__- _ ------_-__ _ _ _ _ _ -- - .-_-_ _-- _ - _ -_ _ -_--_ __ _ TSM-215PD05.08, TSM-220PD05.08, TSM-225PD05.0 M- 230PD05.08, TSM-235PD05.08, TSM-240PD05.08, TSM-245PD05.08, Mounting Systems, Mounting Devices, Clamping Devices and Ground Lugs for TSM-250PD05.08, TSM-255PD05.08, TSM-260PD05.08. Use with Photovoltaic Modules and Panels NRTL Listed PV Modules: Hanwha SolarOne: Models HSL60P6-PB-2-230Q, HSL6OP6-PB-2- See General Information for Mounting Systems. Mounting Devices Clamping Devices and Ground Lugs for Use with Photovoltaic Modules and 235Q, HSL60P6-PB-2-240Q, HSL60P6-PB-2-245Q, HSL60P6-PB-2- an I 250Q, HSL60P6-PB-2-255Q, HSL60156-PB-2-260Q, HSL6OP6-PB-2- 265Q, HS1_60P6-PB-2-270Q; HSL6OP6-PB-4-230Q, HSL60P6-PB-4-235Q, HSL60P6-PB-4-240Q, SUNRUN SOUTH LLC, DBA SNAPNRACK E359313 HSL60P6-PB-4-245Q, HSL60P6-PB-4-250Q, HSL60P6-PB-4-255Q, 775 Flero Ln HSL6OP6-PB-4-260Q, HSL601156-1513-4-265Q, HSL60P6-PB-4-270Q; Suite 200 may be followed by additional suffixes. San Luis Obispo, SUCH AS 93401 USA Suniva Inc - OPTXXX-60-4-YYY; Investigated where XXX may be numbers 240 to 270 in increments of 5; Investigated for System Fire where YYY may be 100; OPTXXX-60-4-YYY; Cat. for Mechanical Classification where XXX may be numbers 235 to 265 In Increments of 5; No. Bonding Loading (A, B or C) Tested in Combination With where YYY may be 1130. Photovoltaic mounting system Series N N A Type 1 and Type 2 PV Modules Series And N - UL Listed PV Modules: 100 350 REC Solar AS: REC214, REC215, REC220, REC225, REC230, REC235, REC240, REC245, REC250, REC255, REC260, REC265, Trademark and/or Tradename: "SNAPNRACK" REC270, all followed by PE, PE(BLK), PE -US, PE-US(BLK), PE Q2 or PEQ3. Last Updated on 2015-01-22 Hyundai Heavy Industries Co Ltd: Questions? Print this nape Terms of Use Paw Top HiS-MxxxMG Series - HiS-M210MG, HiS-M213MG, HiS-M215MG, HiS-M218MG, HiS-M220MG, HiS-M223MG, HiS-M225MG, HiS- M228MG, HiS-M230MG, HiS-M233MG, HiS-M235MG, HiS-M238MG, HiS-M240MG, HiS-M243MG, HiS-M245MG, HiS-M248MG, HiS- M250MG, HIS-M253MG, HiS-M255MG, HiS-M258MG, HiS-M260MG, HiS-M263MG, HIS-M265MG, HiS-M268MG, HiS-M270MG; HiS-SxxxMG Series - HiS-S220MG, HiS-5223MG, His-S225MG, HiS-S228MG, HiS-S230MG, HiS-S233MG, HiS-S235MG, HiS- S238MG, HiS-S240MG, HiS-5243MG, HiS-5245MG, HiS-S248MG, HiS-S250MG, HiS-S253MG, HiS-S255MG, HiS-S258MG, HiS- S260MG, HiS-S263MG, HiS-S265MG, HiS-S268MG, HiS-S270MG, HiS-5273MG, HiS-S275MG; all may be followed by the suffix BK or blank. Renesola Jiangsu Ltd: JCxxxM-24/BB Series - JC200M-24/Bb, JC205M-24/Bb, JC210M-24/13b, JC215M-24/Bb, JC220M-24/13b, JC225M-24/Bb, JC230M-24/Bb, JC235M-24/Bb, JC240M-24/13b, 3C245M-24/Bb, JC250M-24/Bb, JC255M-24/Bb, JC260M-24/Bb, Series And N JC265M-24/Bb, JC270M-24/Bb. 100 Suniva Inc - MVX-235-60-5-701, MVX-240-60-5-701, MVX-245-60- 5-701, MVX-250-60-5-701, MVX-255-60-5-701, MVX-260-60-5-701, MVX-265-60-5-701; MVX-235-60-5 7B1, MVX-240-60-5-7131, MVX-245-60-5-7131, MVX- 250-60-5-7B1, MVX-255-60-5-7131, MVX-260-60-5-7131, MVX-265- 60-5-7B1; OPT -250-60-4-800, OPT -255-60-4-800, OPT -260-60-4-800, OPT - 265 -60-4-800, OPT -270-60-4-800, OPT -275-60-4-800; OPT -250-60-4-880, OPT -255-60-4-8130, OPT -260-60-4-8B0, OPT - 265 -60-4-880, OPT -270-60-4-860, OPT -275-60-4-880. Yingli Energy (China) Co Ltd - YLXXXP-29b Series - YL215P-29b, YL220P-29b, YL225P-29b, YL230P-29b, YL235P-29b, YL240P-29b, YL245P-29b, YL250P-29b, YL255P-29b, YL260P-29b; YLXXXA-29b Series- YL220A-29b, YL225A-29b, YL230A-29b, YL235A-29b, YL240A-29b, YL245A-29b, YL250A-29b, YL255A-29b. ©2015 UL LLC When the UL Leaf Mark is on the product, or when the word "Environment" is Included in the UL Mark, please search the UL Environment database for additional information regarding this product's certification. The appearance of a company's name or product In this database does not in itself assure that products so Identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow -Up Service. Always look for the Maris on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non - misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2015 UL LLC". ,�` .� a r I /�'� Ulr 1 iNO o, v it9� Bding Dn-P21't-rent if 'qAR 2016 REVIEWED FOR C;)uE COMPLIANCE: Reviewed fay OWNFER CERTIFICATE OFCOMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISION 10300 TORRE AVENUE - CUPERTINO, CA 95014-3255 (408) 777-3228,, FAX (408) 777-3333 - building(ftupertino.ong PFIRIVtITCAL N -NOT BP,]4r-INAI,r,,DknCOMPLFYEDU T11,TWSC1F,'ft N . T-fFICAT 40 MN ANDM== " *JF1 KOTNG WVW" PURPOSE This affidavit is a self -certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R314, 2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. GfENEHAL INFORMATION Existing single-family and multi -family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds $1000.00, CRC Section 8314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations: ARIA Outside of, each, separate sleeping area in the immediate vicinity of the bedroorn(s) SMOKE ALARM X COAIA 'A X On every level of a, dwelling, unit including basements X Within each sleeping, room, X Carbon Monoxide alarms �s are" not required in t, dwellin p which do riot c ontain fuel -burning appliances and that donot Dave ariattached garage; Carbon monoxide alarms combined with smoke alarms shall comply wi'tIrt, CBC Section 42'0.6 -and shall be approved by the Office o f the State F ire Marshal. Power, Su In dweliling, units with no commercial m—er, cial power supply, mm , (s), maybe -y aliax be solely battery opera tion d0 In existingdwellarug.imfts,, alarms are pernuitted to be solely battery operated where repairs or itera, s, not result mi the, removal 4 wall and ceiling firdslitea or there Is, no, access, by m—ean-s, of, attic, base ma, ent or eraW11, CBC Secttiiants,907.2.11.4and 420162. isrequired for , allamno, whic h) moist: We c em-tected, to, the buildh qg, wining. ,As- owner eg the ab�ove-referertced p-roperly, Thereby certify Ileal thie Alairmn(s) refei-reirteedi above h&s,/Tja,.ve bee]% amd Caffitio-mia, Residerdral, Codes. The alarms have beei% tested a mid are operationa-11, as, of the date signed bellow.. 11 h, -aua� readgqdi awag, b) comy nivwcth On- t4 --m- & anf d am rdfflh ni s, @ ff fhik, s p 1b, —e- t T pori Mre!" W kh- .............................. ....... ................. .... .... .. V VL/ 61 Shioke and,-'CO)f6rm dbcc r-eWs.e&03/T81JW; ` iT".,,,PLU�MMND ",F-IXTU,�,,ttES OWNER CER TIM',.AT'E OF COMPLIANCE COMMU1 -NITY IDEVEL, „t 'T BEpARTWEIST- BULDXG DIVIStOW CUPERTI NO 10300! TIORREAVE-NUE - CUDERTMIN-0, GA%0,14-32,55 Owner N Address 1. Is Your real property a registered historical site? El es Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. Go to Question 2. -PO 2. Does your real property havea -licensed plumber certifying that,t' due to the age or configuration of the property or its plumbing, installation of wata=conserving plumbing fixtures is not technically feasible? El Yes Civil Code Sections 1101.1 through 1101.8 donot apply. F1 The licensed plumber's, certification has been provided to the Building Division., Skip the rest of the form and sign bottom of form. F- 9No Go to Question 3. k4 Is water service perft.=' ently disconnected for your building? El Yes Civil Cade Sections 1101.1 through 11018 do 4.Si �:L 00 to Question 4. no app—k' "ea ofthe form KEW sign bottom of form. 4. Is your real property built and available for use or occupancy on or before January 1, 1914? 0 No My teal property is built and available for use or occupancy after January 1, 1594. P -M Civil Code Sections 1101.1 th-ro-ugh, 1101.8 do not apply. Skip the rest of the forth and sign bottom of form. Yes My teal property is built and available for use or occupancy on or -before January 1, 1994. Civil C-qde, Sections, 1101.1 through 1101..8 apply. Check one of the three following statements and sign bottom. of form.. 5. Please check QTM of tl'ie, following: My PjfGP6ftSr i"'; a� ghVW&fn'17 Midelftial MA property.. See Civil Code Section 1101.4. On and after, J anuaiy 1, 10141, Building alterations or, improvements vements shan require all non-compliant plumbing fixtures to be replaced with. water-constrving, plumbing, fixtures throughout the building. 021 or before January 1, 2017, all non- compliant plumbing fixtures, shall be replaced with Water-consarviOg Plu'm"bk% fixtures (regardless Of whether property undergoes alterations or improvements}. 0 MYprqPer(yi,&, zt =Ififamffy regUentiol real, property. , gee Civil Code Section 1101.5, On and after. Ja'nuaty 1, 20114, specified building dtaadOM OF improvements, shall FequiTe non- compliant plumbing bing Extureg. to, be replaced. with waterconserving plumbing fixtures. On or before Januaryreplaced i, �_ water Conserving plumbing fixtures, throughouts, S, be P 2ged W fil improvemeap). the building (regardless Of WhMtktr proptAy im&rgoes alterations or ❑ 1v1y property ins, a commercial realer=operty, See Civil Code Section 110`1.x. On and. after January 1, specified Building Alterations or improvements shall require non- compliant Plumbing fixtures: to, be replaced with, water conserving p=lumbing fixtures.. OR or before. January 1, 28$91„ all non-compliant pl'uMbing, fixtures shall be replaced with water- conserving, pluin, Hkaig futures, dMonfi, 0 -at the: building.(regax,&ess-of whether property undergot's, alleitatians or; m provements)� 1, as the owner ori owner's agent of this propentyr, certify under penally of perjury that non compfiant Flu, m-bi ng fixtures, will be 0 replaced prior to) date', speeified abov e-wvitht water conserving p1ta. mbing fixtures, in, accordance with Civil-. Code Sections 1, 1� a -I. 1, -thuough 11013,, the Cede and Cal'iforn. is Green,,B".uilding. Standards, Code, andmanufar-hurer's 'tui requirements, a�ndithat t.ht.water-conservi.ngplumbing fixtures comply with the requirements as indicated in the 121 j J-%� A Owner or Own, -er(A@pn V& SIW, atu ed. Da,(�?W Upon compratibg widsigniiig, this Ces%V&ate, plzfs'eretW�� it to the Building Division, in. order SB487201d. dbc revised' 0812 611S