15100040I CITY OF CUPERTINO BUILDING PERMIT I BUILDING ADDRESS: 22342 MCCLELLAN RD CONTRACTOR: SOLARCITY PERMIT NO: 15100040 OWNER'S NAME: CHIEN MING L 13055 CLEARVIEW WAY I DATE ISSUED: 10/06/2015 I OWNER'S PHONE: 4082521933 SAN MATEO, CA 94402, PHONE NO: (650) 638-1028 LICENSED CONTRACTOR'S DECLARATION License Class C.1 ,CA.,1;) Lic. # Contractor R" ki$ 1 k`\ Da" -A 16. / f I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. JOB DESCRIPTION: RESIDENTIAL ❑ COMMERCIAL ❑ INSTALL (N) 12 ROOFTOP PV PANELS (3.12KW) Sq. Ft Floor Area: I hereby affirm under penalty of perjury one of the following two declarations: 1. I have and will maintain a certificate of consent to self -insure for Worker's APN Number: 35705060.00 Compensation, as provided for by Section 3700 of the Labor Code, for the C1 performance of the work for which this permit is issued. have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless,t e City of Cupertino against liabilities, judgments, costs, and expenses which q, acctu against said City in consequence of the granting of this permit. A itional the applicant understands and will comply with all non -point source reg �ins,pdr the Cupertino Municipal Code, Section 9.18. Signature f°" _.__ Date 1 0 6 I.-5 ® OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: 1. I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) 2. I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.7044, Business & Professions Code). I hereby affirm under penalty of perjury one of the following three declarations: 1. I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Signature Date Valuation: $6500 Occupancy Type: PERMIT EXPIRES IF WORK IS NOT STARTED WITHIN 180 DAYS OF PERMIT ISSUANCE OR 180 DAYS FROM LAST CALLED INSPECTION. Issued Date: R� RE -ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. Signature of Applicant: Date: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER HAZARDOUS MATERIALS DISCLOSURE I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defineA by the Bay Area Air Quality Management District I will maintain compliance -w th t Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Cod , Secti ns 25505, 25533, and 25534. i Owner or auxhofM- Date. • CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name Lender's ARCHITECT'S DECLARATION I understand my plans shall be used as public records. Licensed Professional i� Al TERNATJVE ENERGY PERMIT APPLICATION AE ! -..-.. -,.• .. ,:.: r. �. ..did �. 2�i - U3 ERTI l � . m_ _._. PROJECT ADDRESS APN 9 OWNER NAME�Ifr �7 PHONE C: ` 9—s CA E -✓IASL STREET ADDRESS,2 C CITY, STATE, ZFAX 0 CONTACT NAME Marjan Javanrraard � PHONE 650.477.6430 mjavanmard@solarcaty.coln STREETADDRESS391 Foster City Blvd CITY; STATE, ZIP Foster City, CA 944041 FAX ❑ OWNER ❑ OWNER -BUILDER ❑ OWNER AGENT ❑ CONTRACTOR ® CONTRACTOR AGENT ❑ ARCMTECT ' ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTORNAIMESolarCity Corporation LICENSE NUMBER LICENSETYPEP��o BI,S.L"28840 COMPANY NAME SolarCity Corporation E-MAILmjjavanmard@solarcity..com FAX STREET ADDRESS 391 Foster City Blvd CITY, STATE, ZIP Fester City, C /1 9/' /' 04 sera -€-r PHONE 650.477.6430 ARCHITECT/ENGNEER NAME LICENSE NUMBER BUS. LIC k COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE USE OF ( SFD or Duplex ❑ Multi -Family PROJECT N WILDLAND PROJECT N STRUCTURE: ❑ Commercial URBAN INTERFACE AREA ❑ Yes ❑ No FLOOD ZONE ❑ Yes ❑ NO SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATERHEATING ❑ OTHER: FOR SOLARPA,VELS. NUMBER OFPANELS/UNTTS: ; g - KILOWATTS (COMMERCIAL ONLY):3 : I ` TOTAL VALUATION . �J DESCRIPTION OF WORK Installation ( ) rooftop flush mounted solar panel ) kW I By my signature below, I certify to each of the following: I am the property owner or authorized agent to act on the property owneK s be . I have read t Ss application and the information I have provided is correct. I have r the.D 'scription of Work and verify it is accurate. I agree to copy with all applicable local g ordinances and state laws relating to building construction. I_autIL( ee..r, esentatives of Cupertino to enter the above-iden�tified prope for inspection purposes. Signature of ApplicantlAgent: Date:�� / 0 SUPPLEMENTAL- ORMATION REQUIRED OFFICE USE ONLY F - E ❑ E1PREss ,4 U ❑ STANDARD El U LARGE El1~ IVIArOR PVApp_2011.doe revised 03116111 CITY OF CUPERTINO FEE ESTIMATOR - BUILDING DIVISION M ADDRESS: 22342 MCCLELLAN RD DATE: 10/06/2015 REVIEWED BY: PHUONG APN: 357-05-060 BP#:. *VALUATION: $6,500 PERMIT TYPE: Building PermitPLAN CHECK TYPE: Alteration / Repair PRIMARY SFD or Duplex USE: $0.00 PENTAMATION SOLAR -RES PERMIT TYPE: WORK INSTALL N 12 ROOFTOP PV PANELS 3.12K l_ SCOPE $0.00 AJech..F'lct. {"heck. 11hjtnh, 111a hie�ft. f'errzaft f �:e: I'ltirr�. 1'ern2 , Fee: Efec'. rj.-I-frit Fee: _L_ 0iher 4C,,h_Fr c z: t) her.P11V1?b .1nsp. L I I'l c Heck hzm Fee: 1)himb. Irs;a Fee: EI&C. Irxsp. 1•ee: NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School n-... -IF- e t ' t tcb d the reliminar in ormation available and are onlyan estimate. Contact the Dept or addn't info. Th ese ees are ase on FEE ITEMS (Fee Resolution 11-053 Ef. 711/13) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 # Alternative Energy System $236.00 IPHOTovREs Photovoltaic System Suppl. PC Fee: (F) Reg. 0 OT . 0.0 hrs $0.00 PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Fee: Reg. Q .OT 0,0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 T7= ('011,5 t rucl ion Tax: A(Ir9inh7 rayfi! e I,' ee 0 G Work Without Permit? 0 Yes (F) No $0.00 Advanced. Planning Fee: $0.00 Select a Non -Residential 0 Building or Structure Ytt1e?11�c?c; tt717s'YtiLtitt3tz.Ie':i: Strong Motion Fee: 1BSEISMICR $0.85 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $1.00 i 0' ,ASS =' $1.85 $236.00 TOTAL FBF;: ' $237.85 Mevl5eu. W rvu" 1 o Address SMOKE / CARBON MONOXIDE ALARMS OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building(a)cupertino.org )3�2 cCkllan Q. C t -`,, cA PURPOSE FRE This affidavit is a self -certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R314,2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single-family and multi -family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds $1000.00, CRC Section R314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations: AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of the bedroom(s) X X On every level of a dwelling unit including basements X X Within each sleeping room X Carbon Monoxide alarms are not required in dwellings which do not contain fuel -burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. Power Supply: In dwelling units with no commercial power supply, alarm(s) may be solely battery operated. In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl space. Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2. An electrical permit is required for alarms which must be connected to the building wiring. As owner of the above -referenced property, I hereby certify that the alarm(s) referenced above has/have been installed in accordance with the manufacturer's instructions and incompliance with the California Building and California Residential Codes. The alarms have been tested and are operational, as of the date signed below. I have read and agree.to cg/npiy with the terms and conditions of this statement Owner (or Owner Agent's) Name: 1 lo% Si natur ............. ......... ......... ......... .....'...............................,.,................Date ...../.!/j.... Contractor Name: signature................................................................... Lic.#'...................................... Date: ................... Smoke and COfonn.doc revised 03118114 CUPERTINiO Owner Name Address L2-3 WATER -CONSERVING PLUMBING FIXTURES OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 10300 TORRE AVENUE CUPERTINO, CA 95014.-3255 (408) 777-3228 • FAX (408) 777-3333 • building(aD-cupertino.om e/b/i kd _ C -v9. , OA (?;_6J 1,5-�660efV F1� o 1. Is your real property a registered historical site?' Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. No Go to Question 2. 2. Does'your real property have a licensed plumber certifying that, due to the age or configuration of the property or its plumbing, installation of water -conserving plumbing fixtures is not technically feasible? 0 Yes Civil Code Sections 1101.1 through 1101.8 do not apply. 0 The licensed plumber's certification has been provided to the Building Division. Skip the rest of the forrn and sign bottom of form. No Go to Question 3. 3. Is water service permanently disconnected for your building? El Yes • Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. [ n No Go to Question 4, 4. Is your real property built and available for use or occupancy on, or before January -1, 1994? Q No My real property is built and available for use or occupancy after January 1, 1994. Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. V Yes My real property is built and available for use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101.8 apply. Check one of the three following statements and sign bottom of form., 5. Please check ONE of the following: 91 My property is a single-family residential real property. See Civil Code Section 1101.4. On and after January 1, 2014, building alterations or improvements shall require all non-compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non- compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements). El My property is a multifamily residential real property. See Civil Code Section 1101.5.. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water - conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). ❑ My property is a commercial real properly. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall, require non compliant plumbing, fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). I, as the owner or owner's agent of this property, certify under penalty of perjury that non-compliant plumbing fixtures will be replaced prior to date specified above with water -conserving plumbing fixtures in accordance with Civil Code Sections 1101.1 through 1101.8, the current California Plumbing Code and California Green Building Standards Code, and manufacturer's installation requirements, and that the water -conserving plumbing fixtures comply with the requirements as indicated in the table on the following page. //I A ✓ _ , t ___ I I Owner or Owner Agent's Signature: / // / Date: IV/ 1` ((_0 I Upon completing and signing this Certificate, please return it to the Building Division in order to final your building permit. SB407 2015. doe revised 08/26/15 ABBREVIATIONS I ELECTRICAL NOTES I JURISDICTION NOTES A AMPERE PV2 AC ALTERNATING CURRENT STRUCTURAL VIEWS BLDG BUILDING PV5 CONC CONCRETE DC DIRECT CURRENT EGC EQUIPMENT GROUNDING CONDUCTOR (E) EXISTING EMT ELECTRICAL METALLIC TUBING FSB FIRE SET—BACK GALV GALVANIZED GEC GROUNDING ELECTRODE CONDUCTOR GND GROUND HDG HOT DIPPED GALVANIZED I CURRENT Imp CURRENT AT MAX POWER Isc SHORT CIRCUIT CURRENT kVA KILOVOLT AMPERE kW KILOWATT O LBW LOAD BEARING WALL MIN MINIMUM (N) NEW NEUT NEUTRAL NTS NOT TO SCALE OC ON CENTER LU PL PROPERTY LINE POI POINT OF INTERCONNECTION PV PHOTOVOLTAIC w_ SCH SCHEDULE S STAINLESS STEEL STC STANDARD TESTING CONDITION TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPP V VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT 1. THIS SYSTEM IS GRID—INTERTIED VIA A UL—LISTED POWER—CONDITIONING INVERTER. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. 3. A NATIONALLY—RECOGNIZED TESTING LABORATORY SHALL LIST ALL EQUIPMENT IN COMPLIANCE WITH ART. 110.3. 4. WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, A SIGN WILL BE PROVIDED WARNING OF THE HAZARDS PER ART. 690.17. 5. EACH UNGROUNDED CONDUCTOR OF THE MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY PHASE AND SYSTEM PER ART. 210.5. 6. CIRCUITS OVER 250V TO GROUND SHALL COMPLY WITH ART. 250.97, 250.92(B). 7. DC CONDUCTORS EITHER DO NOT ENTER BUILDING OR ARE RUN IN METALLIC RACEWAYS OR ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER ART. 690.31(E). 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY UL LISTING. 9. MODULE FRAMES SHALL BE GROUNDED AT THE UL—LISTED LOCATION PROVIDED BY THE MANUFACTURER USING UL LISTED GROUNDING HARDWARE. 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE BONDED WITH EQUIPMENT GROUND CONDUCTORS. LICENSE GENERAL NOTES CA # 888104 1. ALL WORK TO BE DONE TO THE 2013 C-10 CALIFORNIA BUILDING CODE AND THE 2013 CALIFORNIA RESIDENTIAL CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY THE 2013 CALIFORNIA ELECTRIC CODE. MODULE GROUNDING METHOD: * I AHJ: Cupertino UTILITY: Pacific Gas and Electric Company FLASHING WILL BE PAINTED TO MATCH EXTERIOR CONFIDENTIAL — THE INFORMATION HEREIN IDB NUMBER: JB -9506170 00 PREMISE OWNER: CONTAINED SHALL NOT BE USED FOR THE C H I E N , MING BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN MILU UK IN Com Mount T e C 22342 MCCLELLAN RD PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH MoouLE P CUPERTINO, CA 95014 THE SALE AND USE OF THE RESPECTIVE (12) REC # REC260PEZ SIN: PERMISSIONCITYEOFISOLARCWI INC.OTHE WRITTEN INVERTER: 408 252-1933 FRONIUS Primo 3.8 CC,'M!!t'�"TY DEVELOPMENT DEPARTMENT BUILDING DIVISION - CUPERTINO ArPROVED Thi- r^t cf c!ens and specifications MUST be kept at the 10 rtjing construction. It is unlawful to make any or alterations on same, or to deviate tl-; ; a',Ioin, without approval from the Building Official. Th n' rrplrjg of this plan and specifications SHALL NOT b • '' -Jd t0 perinit or to be an approval of the violation c` - .y provisio City Ordinance or State Law. BY w UIQ Pl�-iMIT NO, 2 10 VICINITY MAP DESCRIPTION: CHIFN RF9DENCE 3.12 KW PV ARRAY TMK OWNER: * PAGE NAME: COVER SHEET CUPERTINO Building Departrnent OCT 0 5 2015 REVIEWED FOR CODE COMPLIANCE Reviewed By. PLOT PL NI DATE PLANNING E T�% 1 CUPERTINO an O (a) w (a) RECEIVED INDEX PV1 COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS PV5 THREE LINE DIAGRAM Cutsheets Attached REV BY DATE COMMENTS REV A I NAME I DATE I COMMENTS s x x * x x -IBM: x s DESIGN: Fernando Peru SHEET: REV: DATE- PV ATE:PV 1 10/4/2015 W4, of Cit Y 3055 Clearview Way Son Mateo, CA 94402 T:(650) 636-1028 F:(650) 638-1029 (888)—SOL—CITY (765-2489) www.solarcity.com CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER: JB -9506170 MOUNTING SYSTEM: Comp Mount Type C (12) REC # REC260PEZ INVERTER: FRONIUS # Primo 3.8 00 PREma OMER: CHIEN, MING 22342 MCCLELLAN RD CUPERTINO, CA 95014 (408) 252-1933 CHIEN RESIDENCE 3.12 KW PV ARRAY PAGE NAME SITE PLAN TOTAL ARRAY AREA (SF): 218 TOTAL ROOF AREA (SF): 2370 TOTAL ARRAY AREA IS a 9.18 PERCENT OF TOTAL ROOF AREA PITCH: 27 ARRAY PITCH: 27 MP1 AZIMUTH: 195 ARRAY AZIMUTH: 195 MATERIAL: Comp Shingle STORY: 2 Stories PITCH: 27 ARRAY PITCH: 27 MP2 AZIMUTH: 195 ARRAY AZIMUTH: 195 MATERIAL: Comp Shingle STORY: 2 Stories CUPERTINO Building Department OCT 0 5 2015 VIEWED FOR CODE COMPLIANCE. Reviewed By: " LEGEND (E) UTILITY METER & WARNING LABEL Inv INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS SITE PLAN Scale: 3/32" = 1' 01, 10' 21' Fernando Perez SHEET: REV: DATE:- PV ATEPV 2 10/4/2015 E W S "'SolarCity. I -A 3055 Cleorview Way Son Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 (888)—SOL—CITY (765-2489) www.solarcity.corn A DC DC DISCONNECT & WARNING LABELS AC AC DISCONNECT & WARNING LABELS O DC JUNCTION/COMBINER BOX & LABELS F DISTRIBUTION PANEL & LABELS Lc LOAD CENTER & WARNING LABELS ODEDICATED PV SYSTEM METER 0 STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR --- CONDUIT RUN ON INTERIOR — GATE/FENCE O HEAT PRODUCING VENTS ARE RED �� 1 I L _-J INTERIOR EQUIPMENT IS DASHED SITE PLAN Scale: 3/32" = 1' 01, 10' 21' Fernando Perez SHEET: REV: DATE:- PV ATEPV 2 10/4/2015 E W S "'SolarCity. I -A 3055 Cleorview Way Son Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 (888)—SOL—CITY (765-2489) www.solarcity.corn 0 4" PV MODULE 5/16" BOLT WITH LOCK & FENDER WASHERS ZEP LEVELING FOOT ZEP ARRAY SKIRT ZEP COMP MOUNT C ZEP FLASHING C (E) COMP. SHINGLE (E) ROOF DECKING 5/16" DIA STAINLESS STEEL LAG BOLT WITH SEALING WASHER (2-1/2" EMBED, MIN) (E) RAFTER 14'-8" �� (E) LBW B SIDE VIEW OF MP2 NTS MP2 X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 64" 24" LANDSCAPE 64" PORTRAIT 64" 20" RAFTER 2X10 @ 16" OC ROOFAZI 195 PITCH 27 ARRAY AZI 195 PITCH 27 STORIES: 2 Comp Shingle CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE RFNFF!T OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. #-ST-ANDOFF JOB NUMBER: JB -9506170 00 MOUNTING SYSTEM: Comi) Mount Tvoe C (12) REC # REC260PEZ INVERTER: FRONIUS # Primo 3.8 INSTALLATION ORDER LOCATE RAFTER, MARK HOLE (1) LOCATION, AND DRILL PILOT HOLE. (2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. (3) INSERT FLASHING. (4) PLACE MOUNT. G(5) INSTALL LAG BOLT WITH SEALING WASHER. (6) INSTALL LEVELING FOOT WITH BOLT & WASHERS. CHIFN, MINC, 22342 MCCLELLAN RD CUPERTINO, CA 95014 (408) 252-1933 4" 9'-10" (E) LBW SIDE VIEW OF MP1 NTS I-1 MPJ X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 64" 24" PORTRAIT 64" 20" RAFTER C.J. 2X10 @ 16" OC 2x6 @16" OC ROOF AZI 195 PITCH 27 STORIES: 2 ARRAY AZI 195 PITCH 27 Comp Shingle Cul�nl AG'CIII��I(`C L.: i. JiJuVvL 3.12 KW PV ARRAY PAGE NAME STRUCTURAL VIEWS CUPERTINO Building Department, OCTECII 0 5 2015 REVIEWED FOR CODE COMPLIANCE Reviewed BY Femando Perez SHEET: REV: DATE PV 3 10/4/2015 I=4. ;SolarCity ' 3055 Clearview Way Son Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 (888)—SOL—CITY (765-2489) www.solarcity.com CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC.. NOR SHALL 11 HE UISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER: JB -9506170 kO.INTINI' QYCTEM: Com Mount Tvpe C REC # REC260PEZ INVERTER: FRONIUS # Primo 3.8 CHIEN, MING 22342 MCCLELLAN RD CUPERTINO, CA 95014 (408) 252-1933 UPLIFT CALCULATIONS 10.04.2015 *a � System Structural Version #49.3 SolarCiPV `YS Design Software Project Information & Table Of Contents Risk Category: II PV System Type SolarC'Ity SleekMount— Comp Roof Camp Roof Layers of Camp Roofin 2 Roof Slope 270 Rafter Spacing 16, O.C. PV System Module Orientation Landscape and Portrait PV Module Area 213 sf PV Module Width 39" PV Module Length 66" Standoff Attachment Hardware Camp Mount Type C Reduced Ground/Roof Live/Snow Loads Ground Snow Load pg 0.0 psf ASCE Table 7-1 Surrounding Roof Snow 0.0 psf ASCE Eq: 7.4-1 Roof Snow Over PV Modules 0.0 psf ASCE Eq: 7.4-1 Wind Design Criteria Wind Design Cade ASCE 7-10 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 110 mph Fig. 26.5-1A Exposure Category C Section 26.7 Roof Style Gable Roof Fig. 30.4-2A/B/C-5A/B Mean Roof Height h 25 ft Section 26.2 Effective Wind Area 1 Module A 17.8 sf IiijifiW509.7.1 Wind Pressure Calculation Coefficients Wind Pressure Exposure Kz 0.95 30.3-1 Topographic Factor Kzt 1.00 f on 26.8 Wind Directionality Factor Kd 0.85 n 26.6_-1, Importance Factor I NA Velocity Pressure qh qh = 0.00256 (Kzt) (Kd) (V^2) 24.94.9 sf Ext. Pressure Coefficient (Up) GCP (Up) -0.88 Fig. 30.4,-2A/B/C-5A/8 Ext. Pressure Coefficient Down GC Down 0.45 Flg?Qt1 RJ�A4 Design Wind Pressure P p = gh GC Equation 30.4-1 Wind Pressure Up p(up) -21.8 psf Wind Pressure Down down 16.0 pst Allowable Standoff Spacings X -Direction Y -Direction Max Allowable Standoff Spacing Landscape 64" 39" Max Allowable Cantilever Landscape 24" NA Standoff Confi uration Landscape Not -Staggered Max Standoff Tributary Area Trib 17 sf PV Assembly Dead Load W -PV 3 psf Net Wind Uplift at Standoff T -actual -199 lbs Uplift Capacity of Standoff T -allow 500 lbs Standoff Demand/Capacity DCR 39.8% Max Allowable Standoff Spacing Portrait 64" 66" Max Allowable Cantilever Portrait 20" NA Standoff Configuration Portrait Not -Staggered Max Standoff Tributary Area Trib 29 sf PV Assembly Dead Load W -PV 3 psf Net Wind Uplift at Standoff T -actual -334 lbs Uplift Capacity of Standoff T -allow 500 lbs Standoff Demand/Capadty DCR 1 66.8% (-HIEN RFCI0DR-F 3.12 KW PV ARRAY PAGE NAME: UPLIFT CALCULATIONS SHEET: REV: DATE PV 4 10/4/2015 CUPERTINO Building Deaparbnent 15 2015 CODE COMPLIANCE '04'arCity 3055 Clearview Way Son Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 (888) -SOL -CITY (765-2489) www.solorcity.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (N) GROUND ROD Panel Number: Inv 1: DC Ungrounded INV 1 — (1) FRONIUS # Primo 3.8 LABEL: A — (12) REC # REC260PEZ CA # 888104 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number: 1006676565 AFCI Inverter; 380OW, 240V, 97%, w/ Antenna PV Module; 260W, 236.6W PTC, MC4, 40mm, Black Frame, ZEP Enabled C-10 INV 2 Underground Service Entrance Voc: 37.8 Vpmax: 30.7 INV 3 1 Isc AND Imp ARE SHOWN IN THF nr. STRINGS IDENTIFIER 200A MAIN SERVICE PANEL �E E� 20OA/2P MAIN CIRCUIT BREAKER Inverter 1 PAR 200A/2P FRONIUS Primo 3.8 (E) LOADS zaov 4GE7c 1 20A/2P �------------------------- ---------------41— DC+ ---�A DC+ Dc- P1,MP2:1x12 IDa B IGND I I EGC———————————— — ————————— —— —— ——— ——— —— —— — ---- ——————— —————— — --pj I N I I EGCIGEC — Z Z c9 GEC TO 120/240V SINGLE PHASE UTILITY SERVICE I I CUPERTINO Building Department i OCT 0 5 2015 FOR CODE COMPLIANCE REVIEWED Reviewed BY. Voc* = MAX VOC AT MIN TEMP POI (1) CUTLER—HAMMER / CH220 PV BACKFEED BREAKER Breaker, 20A/2P, 2 Spaces, Tan Handle /f► A DC — (1) Ground Roll 5/8 x 8, Copper 2 O (1 AWG /10, THWN-2, Black Ic? ( 1 ) AWG g10, THWN-2, RedOIF (2)AWG #10, PV Wire, 60OV, Black Voc* = 494.02VDC Isc = 9.01 ADC (1)AWG #10, THHN/THWN-2, Green EGC Vmp = 368.4 VDC Imp= 8.5 ADC LL.=LL (1 )AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=15.8 AAC (1)Conduit Kit;. 3/4* EMT . . . . . . . . . .. . . .. . ..... . . . . .... . . . . . . .7 (1) AWG #8,. THW472,. Green... EGC/GEC .- (1) Conduit, Kit;. 3/4' . EMT... _ .. . CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., JOB NUMBER: JB -9506170 00 PREMISE OWNER: CHIEN. MING MCCLELLAN RD DESCRIPTION: /� l NI InrrrinrNCr �HIEIv i\CJlutrv� L DESIGN: Fernando Perez �� ■ �'.,;So�arCity '�'" MouNnNG SYSTEM -or ;;, ,- BE Ui�a SLG IN wii"' i im IN PART OTHERS OUTSIDE THE RECIPIENTS Comp Mount Type C 22342 3.12 KW PV ARRAY CUPERTINO CA 95014 MODULES HA ATION, EXCEPT IN CONNECTION WITH ORGANIZATION, r 3055 georview Way THE SALE AND USE OF THE RESPECTIVE (12) REC # REC260PEZ SHS- REV. DATE PV 5 10/4/2015 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. PAGE NAME: (408) 252-1933 THREE LINE DIAGRAM Son T:(650) 638-102te CA 94402 ) 638-1029 (8a8)—SOL-CITY (765-2489) www.solarcity.com NVERTER: [FRONIUSPrimo 3.8 Label Location: (C)(IC)(CB) Per Code: CRC R331.2 Label Location: (DC) (INV) Per Code: CEC 690.14.C.2 Label Location: (DC) (INV) Per Code: CEC 690.53 Label Location: (DC) (CB) Per Code: CEC 690.17 Label Location: (INV) Per Code: CEC 690.5(C) Label Location: (AC) (POI) Per Code: CEC 690.14.C.2 Label Location: (AC) (POI) Per Code: CEC 690.54 Label Location: (AC) Label Location: (DC) Per Code: CEC 690.17 Label Location: (POI) Per Code: CEC 705.12.D.7 Label Location: (POI) Per Code: CEC 690.54; CEC 690.17 Label Location: (D) (POI) Per Code: CEC 690.64.B.4 Label Location: (POI) Per Code: CEC 705.12.D.7 Label Location: (DC)(INV)(CB) Per Code: ('EC 690.35(F) TO BE USED WHEN INVERTER IS UNGROUNDED CUPERTINO Building Department OCT 0 5 2015 REVIEWED FOR CODE COMPLIANCE Reviewed By. -'>�— (AC): AC Disconnect (C): Conduit (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit (INV): Inverter With Integrated DC Disconnect (LC): Load Center (M): Utility Meter (POI): Point of Interconnection ' CON iDENTiAL — THE iNFORMA IIUN HEREIN CONTAINED SHALL NOT BE USED FOR ����i!� 3055 CleaMew Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED San Mateo, CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, Label Set '0 ++�� T:(650) 638.1028 F:(650) 638-1029 888) -SOL -CITY (765-2489) www.solarcity.com EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE I, So I a rC SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. ty ® SolarCitY ® Next -Level PV Mounting TechnologyNext-Level PV Mounting Technology ' SOlar�'=`�,,SolarCity ZepSolar Zep System for composition shingle roofs P 9 y�GMPATA 577 �F ?�p00P�\� MP v &LISTED IY zepsolar.com Zep Gromc - Rauf Atuchment Array Skirl int Description • PV mounting solution for composition shingle roofs • Works with all Zep Compatible Modules • Auto bonding UL -listed hardware creates structual and electrical bond • Zep System has a UL 1703 Class "A" Fire Rating when installed using modules from any manufacturer certified as "Type 1" or "Type 2" Specifications • Designed for pitched roofs • Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467 • Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72" and cantilevers up to 24" Zep wire management products listed to UL 1565 for wire positioning devices • Attachment method UL listed to UL 2582 for Wind Driven Rain This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of Zep Solar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. Components zepsolar.com Comp Mount Part No. 850-1382 Listed to UL 2582 & Mounting Block to UL 2703 i) Ground Zep Part No. 850-1172 Listed to UL 2703 and ETL listed to UL 467 V Interlock Part No. 850-1388 Listed to UL 2703 Array Skirt, Grip, End Caps Part Nos. 500-0113, 850-1421, 850-1460, 850-1467 Listed to UL 2703 CUPERTINO Building Department OCT 0 5 2015 D FOR CODE COMPLIANCE Reviewed By'. d 4- 110W4 DC Wire Clip Part No. 850-1448 Listed UL 1565 This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of Zep Solar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. 02 27 15 ZS for Comp Shingle Cutsheet Rev 04.pdf Page: 1 of 2 02 27 15 ZS for Comp Shingle Cutsheet Rev 04.pdf Page: 2 of 2 HIGH PERFORMANCE SOLAR PANELS REC PEAK ENERGY REC Peak Energy Z -Link Series solar panels are the perfect choice for building solar systems that combine long lasting product quality with reliable power output. REC combines high quality design and manufacturing standards to produce high- performance solar panels with uncompromising quality. REC PEAK ENERGY Z -LINK SERIES 65.55 ±0.1 1.38 — 39.02 _ All measure EFFICIENCY i YEAR PRODUCT WARRANTY YEAR LINEAR POWER OUTPUT WARRANTY c OST YFR US IMPORT DUTY FREE FF TEMPERATURE RATINGS r Nominal Operating Cell Temperature(NOCT) 45.7°C(±2°C) Temperature Coefficient of P,,,,, -0.40 %/°C r Temperature Coefficient of Voc -0 27 %/°C Temperature Coefficient of I5C 0.024 %/°C ELECTRICAL DATA two STC CbUP4 cr.47 -40_.+185°F(-40.. +85°C) Nominal Power - P,,(Wp) 7E :• 60 REC PEmulti-crystalline WattClass Sorting-(Wp) 47.24 Design Load: 3 strings of 20 cells with bypass diodes Nominal Power Voltage -V.IV) 307 w 0.125 in solar glass with anti -reflection Short Circuit Current -I,(A) 724 Max Series Fuse Rating: surfacetreatment Nominal Power Current-I,�m(A) 850 Back Sheet: Double layer highly res istant Open Circuit Voltage -VaIV) 378 Frame: r All measure EFFICIENCY i YEAR PRODUCT WARRANTY YEAR LINEAR POWER OUTPUT WARRANTY c OST YFR US IMPORT DUTY FREE FF TEMPERATURE RATINGS r Nominal Operating Cell Temperature(NOCT) 45.7°C(±2°C) Temperature Coefficient of P,,,,, -0.40 %/°C r Temperature Coefficient of Voc -0 27 %/°C Temperature Coefficient of I5C 0.024 %/°C ELECTRICAL DATA two STC CbUP4 , . -40_.+185°F(-40.. +85°C) Nominal Power - P,,(Wp) 7E Cell Type: 60 REC PEmulti-crystalline WattClass Sorting-(Wp) ./- Design Load: 3 strings of 20 cells with bypass diodes Nominal Power Voltage -V.IV) 307 Glass: 0.125 in solar glass with anti -reflection Short Circuit Current -I,(A) 724 Max Series Fuse Rating: surfacetreatment Nominal Power Current-I,�m(A) 850 Back Sheet: Double layer highly res istant Open Circuit Voltage -VaIV) 378 Frame: Anodized aluminum (black) Short Circuit Current -Isc(A) 9.01 Zep Groove compatible Panel Efficiency(%) 158 Junction Box: IP67rated - — 0.156 in (12 AWG) solar cable, 2 x 4724 in The electrical characteristics arewithin -/-10% ofthe indicated valuesof l Va and PMS at standard Test conditions Values at standard test conditions STC(airmass AM IS, irradiance 1000 WTW,ell temperature 77°F(25°C)). (STC). Connectors: H4Amphenol At low irradiance of 200 W/ma(AM IS& cell temperature 77°F(25`C))at least 97% of the STC panel efficiency will be achieved- Origin: Made In Singapore Nominal Power-P,p(Wp) 197 Operational Temperature -40_.+185°F(-40.. +85°C) Nominal PowerVoltage-V.(V) 29.0 Maximum System Voltage: 1000VUL Nominal Power Current -I,,(A) 6.81 Design Load: 501bs/ft2(2400Pa) longside Open Circuit Voltage -Voc(V) 35.7 301bs/ft2 (1436 Pa) short side Short Circuit Current -I,(A) 724 Max Series Fuse Rating: 15A Nominal operating cell temperature NOCT(800 W/m2,AM1.5, windspeedI m/s, ambient temperature 687(20°C). Max Reverse Current: ISA 10 year product warranty. Dimension; 65.55x39.02x1.57in(1665x991x40mm) C &us 25 year linear power output warranty Area: 1775ft20.65ml LISTED (max. degression in performance of 0.7% p.a.). UL 1703, Fire rating: Type 1, Class C Weight: 43 lbs (19.5 kg) Note! All given specifications are subject to change without notice at any time. REC is a leading global provider of solar energy solutions. With more than 15 years of experience, we offer sustainable, high performing ^ products, services and investments for the solar industry. Together with our partners, we create value by providing solutions that better R EC meet the world's growing energy needs. REC is headquartered in Norway and listed on the Oslo Stock Exchange (ticker: RECSOL). Our 1,600 employees worldwide generated revenues of USD 647 million in 2013. www.recgroup.com CUPERTIN4 Building Department 5 ZC1r. L'!, 1 V •� J REVIEWED FOR CODE COMPLIANCE Reviewed By: / Perfect Welding / Solar Energy / Perfect Charging v- - SHIFTING THE LIMITS FRONIUS PRIMO / The future of residential solar is here - Introducing the new Fronius Primo. r �"3 /PC board /SnaplN-,w /Wi Fi'D. /SuperFles /Smart Grid / Arc Fault Cir,cil replaccinenl process mourning bystetn interface Design R-dy Inte"'I'linn / With power categories ranging from 3.8 kW to 8.2 kW, the transformerless Fronius Primo is the ideal compact single-phase inverter for residential applications. The sleek design is equipped with the SnaplNverter hinge mounting system which allows for lightweight, secure and convenient installation and service. / The Fronius Primo has several integrated features that set it apart from competitors including dual powerpoint trackers, high system voltage, a wide input voltage range and unrestricted use indoors and outdoors. Other standard features include a Wi-Fi* and SunSpec Modbus interface for seamless monitoring and datalogging, Arc Fault Circuit Interruption (AFCI), and Fronius's superb online and mobile platform Fronius Solar.web. The Fronius Prime, is designed to adjust to future standards, offering a complete solution to code restrictions and technical innovations of tomorrow. It also works seamlessly with the Fronius Rapid Shutdown Box for a reliable NEC 2014 solution. TECHNICAL DATA FRONILIS PRIMO GENERAL DATA Diru _ions p+kith x heigW t depth) Weight Degree of prot"h Night time consumption Inverter topology Cooling Insndlanon Ambien) operating temperature rang, - Po ,ntod humidity DC-ouccimn terminals AC a,nuc(tion t, "A' Cenif rains and cnmphance with st-danh PROTECTIVE DEVICES UC n�u.c polarity prone ran STANDARD WITH ALL PRIMO MODELS 16.9 x 247 r fit iii. 47.19 11, .\E91r1 1\ I IV T,,o,1,inu 1e Variable speed fan Indoor and oun,) i i'lal nion -40 ... 13J -F (40.--+55'Q 0.100 4. DC. and 4x DC- c- tcnnivals far copper (solid/ stranded / fine stranded) or aluminum (solid J stranded) Screw lerniinals 12-6 AWG UL 1741-2010, U1998(for functions: AFCI andisoletion monitoring). IEEE 1547-2003, IEEE 1547.1-2003, ANSI/IEEE 062.41, FCC Pan 15A& R, NEC Article 694 ( 22- 2N, 107.1-01 (September 3001) IIIL1699B Issue 2-2013, CSA TIL NI -07 Issue 1-2013 STANDARD WITH ALL PRIMO MODELS 1 - INTERFACES STANDARD WITH ALL PRIMO MODELS WI-Ffj Ether pct;Serial W-« 9c taoda,d 802.11 b n• 1- imus 5,,1 u -b, S iSp,, Nl(,dbus ICE ISDN / tin Spir N1od's RI II 6 inputs or 4 digital inputzlnn p�1� External relay controls USB (A socket) Datalogging and/ur updating via USN 2x RS423 (R145 socket) Fronius Solar Net. interlace protocol Dawloggcr and Wcbmwer lur hided 'The term Wi-Fi® is a registered trademark of the Wi-Fi Alliance. TFCHNICAL DATA FRONILIS PRIMO INPUT DATA PRIMO 3.8-1 PRIMO 5.0-1 PRIMO 6.0-1 PRIMO 7.6-1 PRIMO 8.2-1 Rcconuucnded 1'V power (kWp) 3.0 6.00V 4.0 -7.1f klN -I.n 9.5 k\V t,_1 - 11.7 k\V o r, I2." k\\ Max. usable input current (MI'PT 1/N1PP'r 2) 18 A/ 18 A 18 A / 18 A IR A / 1 F A 18 A / 16 A 18 A / 18 A Total niax. DC ,-uncut \ Max. array short circuit current _. 12.5 A Upc 'I"ng colsigc range h0 V' 00o V Mux. input vobage 600 V Nui moat input ...Inge 410V 420 V 420 V 420 V 420 V Admin=_able conductor ein DC AWG 14.. AWG 6 MPI' Vu11'g; Range 200 4h0 V 240- 410 V 240-410 V 2 U 480 V 370-480 V Number of MPPT - Srunngrvflh serial number 2vv096u, before >erial nun,bcc 150 V OUTPUT DATA PRIMO 3.8-1 PRIMO 5.0-1 PRIMO 6.0-1 PRIMO 7.6-1 PRIMO 8.2-1 91:,x. uutpul p 20S 3800 IV 50011 W 6000 \V 7600 %V 171011 W 240 3800 W 500IN 6000 W 7600W 82001N M-a.e_ coininuuus output c-ununl 208 18.3 A 24.0 A 28.8 A 36.5 A 38.0 A 240 15.8 A 20.8 A 25.0 A 31-7 A 34.2 A Rc""ct­ Ld l)CPD�A( b"A" site 208 2.-, A 311 A 40 A 50 A 0 A 240 20A 3o A 35A 10 A 45 A utas L(flcieucy 96.7';, 96.9 ", 96 9 " 6 96.9 "6 97.0 "! CEc. Rlraciency 240 95.o % 95.5%, 96.0 °6 96o% 96.5 ndmis.ablc cndrirlo� I - AC AWG 14- AWG 6 Grid comtecnon 208/240 F -1--y 60 Hr. Tolul harmonic distortion to i PmV" factor (' os'P.,or) 0.ri> 1 io&, ip ,UPERTINO Building Department OCT 0 5 2015 REVIEWED FOR CODE COMPLIANCE i<eviewed By s / Perfect Welding / Solar Energy / Perfect Charging WE HAVE THREE DIVISIONS AND ONE PASSION: SHIFTING THE LIMITS OF SSIBILITY. / Whether welding technology, photovoltaics or battery charging technology - our goal is clearly defined: to be the innovation leader. With around 3,000 employees worldwide, we shift the limits of what's possible - our record of over 1,000 granted patents is testimony to this. While others progress step by step, we innovate in leaps and bounds. lust as we've always done. The responsible use of our resources forms the basis of our corporate policy. Further information about all Fronius products and our global sales partners and representatives can be found at v .fronius.com Fronius USA LLC 6797 Fronius Drive Portage, IN 46368 USA pv-support-usa@fronius.com www.fronius-tisa.com `i SolarCity ZepSolar DWV Debris Guard for composition shingle roofs Next -Level PV Mounting Technology DWV Debris Guard Construction Detail Debris Guard, close up �QGpMP4TZe` Prevent blockages and keep vents open with the DWV Debris Guard. Protects against: Leaves Rain rFAcOmPP�\0� Pine needles Insects • Snow Birds DWV Debris Guard is made of rugged 26 gauge galvanized steel. CUPERTINO Building Department OCT 0 5 2015 REVIEWED FOR CODE COMPLIANCE Reviewed By: zepsolar.com This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of ZepSolar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. Document # 800-1677-001 Rev A Date last exported: April 3. 2015 4:04 PM