B-2016-1523CITY OF CUPERTINO BUILDING PERMIT
BUILDING ADDRESS:
CONTRACTOR:
PERMIT NO: B-2016-1523
21541 REGNART RD CUPERTINO, CA 95014-4818 (356 22 004)
WEST COAST SOLAR
INC
BRENTWOOD, CA
94513
OWNER'S NAME: Mr & Mrs KYUNGWHA AND JAE M SONG
DATE ISSUED: 03/15/2016
OWNER'S PHONE: 408-446-1557
PHONE NO: (925) 516-3900
LICENSED CONTRACTOR'S DECLARATION
BUILDING PERMIT INFO:
License Class ROOFING Lic. #908549
Contractor WEST COAST SOLAR INC Date 12/31/2017
X BLDG _ELECT _PLUMB
MECH X RESIDENTIAL COMMERCIAL
I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing
_
with Section 7000) of Division 3 of the Business & Professions Code and that my
license is in full force and effect.
JOB DESCRIPTION:
Installation of roof mounted solar (9 modules) (2.34 kW)
I hereby affirm under penalty of perjury one of the following two declarations:
1. I have and will maintain a certificate of consent to self -insure for Worker's
Compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
2. I have and will maintain Worker's Compensation Insurance, as provided for by
r
Section 3700 of the Labor Code, for the performance of the work for which this
Sq. Ft Floor Area:
Valuation: $9000.00
permit is issued.
APPLICANT CERTIFICATION
I certify that I have read this application and state that the above
information is correct. I agree to comply with all city and county ordinances
APN Number:
Occupancy Type:
and state laws relating to building construction, and hereby authorize
356 22 004
R3
representatives of this city to enter upon the above mentioned property for
inspection purposes. (We) agree to save indemnify and keep harmless the
City of Cupertino against liabilities, judgments, costs, and expenses which
PERMIT EXPIRES IF WORK IS NOT STARTED
may accrue against said City in consequence of the granting of this permit.
WITHIN 180 DAYS OF PERMIT ISSUANCE OR
Additionally, the applicant understands and will comply with all non -point
source regulations per the Cupertino Municipal Code, Section 9.18.
180 DAYS FROM LAST CALLED INSPECTION.
Signature SAVA6Date 03/15/16
Issued by: Sean Hatch
Date: 03/15/16
OWNER -BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for one of the
RF,-ROOFS:
following two reasons:
All roofs shall be inspected prior to any roofing material being installed. If a roof is
1. I, as owner of the property, or my employees with wages as their sole
installed without first obtaining an inspection, I agree to remove all new materials for
compensation, will do the work, and the structure is not intended or offered for
inspection.
sale (Sec.7044, Business & Professions Code)
2. I, as owner of the property, am exclusively contracting with licensed
Signature of Applicant:
contractors to construct the project (Sec.7044, Business & Professions Code).
Date: 03/15/16
I hereby affirm under penalty of perjury one of the following three declarations:
ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER
1. I have and will maintain a Certificate of Consent to self -insure for Worker's
Compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
HAZARDOUS MATERIALS DISCLOSURE
2. I have and will maintain Worker's Compensation Insurance, as provided for by
I have read the hazardous materials requirements under Chapter 6.95 of the
Section 3700 of the Labor Code, for the performance of the work for which this
California Health & Safety Code, Sections 25505, 25533, and 25534. 1 will
permit is issued.
maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the
3. I certify that in the performance of the work for which this permit is issued, I
Health & Safety Code, Section 25532(a) should I store or handle hazardous
shall not employ any person in any manner so as to become subject to the
material. Additionally, should I use equipment or devices which emit Hazardous
air contaminants as defined by the Bay Area Air Quality Management District I
Worker's Compensation laws of California. If, after making this certificate of
will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and
exemption, I become subject to the Worker's Compensation provisions of the
the Health & Safety Code, Sections 25505, 25533, and 25534.
Labor Code, I must forthwith comply with such provisions or this permit shall
be deemed revoked.
wneror authorized agent:APPLICANT
CERTIFICATION .Ae
Date: 03/15/16
I certify that I have read this application and state that the above information is
CONSTRUCTION LENDING AGENCY
correct. I agree to comply with all city and county ordinances and state laws
I hereby affirm that there is a construction lending agency for the performance
relating to building construction, and hereby authorize representatives of this city
of work's for which this permit is issued (Sec. 3097, Civ C.)
to enter upon the above mentioned property for inspection purposes. (We) agree
Lender's Name
to save indemnify and keep harmless the City of Cupertino against liabilities,
judgments, costs, and expenses which may accrue against said City in
Lender's Address
consequence of the granting of this permit. Additionally, the applicant understands
and will comply with all non -point source regulations per the Cupertino Municipal
ARCHITECT'S DECLARATION
Code, Section 9.18.
1 understand my plans shall be used as public records.
Licensed
Signature Date 03/15/16
Professional
CUPERTINO
ALTERNATIVE ENERGY PERMIT APPLICATION
COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISION
10300 TORRE AVENUE • CUPERTINO, CA 95014-3255
(408) 777-3228 • FAX (408) 777-3333 • building a5cuoertino.org
PROJECT QDR SA541 e 1 Q V A ' d
K
I APN R
OWNER NAMIE
- 3ovt 8 J e l om v-\
PHONE
NO>s - y 6 - 155-1
E-MAIL
STRtE Tf'DDRE�
1 �
I CITY, STATE, ZIP
FA
FAX
� � I
�
u2fvI
�P
N,
C ACT NAE
yr v ow \
Ohm
- l -39ao
E-h/L&IL
[Av\r4 M &w A-CoaSl-',1solgr
S TREET ADbkESS
15 �ttc Wa S� e C
Y, STATE, ZIP
.mood y S I
FAX
Ok^\--EA ❑ OWK.-R-BUILDER ❑ ORrta AGEtv-I' ❑ CO3\7/.0 op' XON-1R4CTORAGE1,'r ❑ ARCI=CT ❑ ENGINEER ❑ DEV=LOPER ❑ itNANr
CONTRkCTOR "? E a
Rol, Inc,
LICENSE iL�4 ER
LICENSE TYPE
Oct
Bus. C� I
COMPANY NAI,4E
E-MAIL
Lavr van Solaf• -ov-n
FAX
STR j ADDRESS
IS lber• vt Wa Sv�� E
, STATE,IPP
PHONE n O
`3 (�
ARCMTECT/ENGINEER N.M4E
I LICENSE NU1,4BER
I BUS. LIC R
COMPANY NAME
E-M.AIL
FAX
STREET ADDRESS
CITY, STATE, ZIP
PHOI\t
USE OF ❑ SFD or Duplex ❑ IlIulti-Family
PROJECT IN WILDLAND
PROJECT IN
STRUCTURE: ❑ Commercial
URBAN INTERFACE AREA ❑ Yes ❑ NO
FLOOD ZONE ❑ Yes ❑ NO
❑ SOLAR PANELS
❑ ELECTRIC VEHICLE CY 4RGING
STATION
❑ SOLAR \',LATER I'.EATING
❑ OTHER:
FOR SOLAR PANELS. NUMBER OF^ ANELS/U'NITS:
(�
KILOWATTS (CONIN- ERCIAL ONLI�:
TOT VF ATIION: O
(J
DESCRIPTION OF WORK
2v1 Uot
Kw
By my signature below, I certify to each of the following: I am the property owner or authorized agent to act on the property o«ater's behalf. I havereadthis
application and the information I have provided is correct. I have
read the Description of Work and verify it is accurate. I agree to comply With all applicable local
ordinances and state laws relating to building construction. I authorize representatives of Cupertino to enter the for inspection purposes.
Signature of Applicant/Agent:
��appboovve-identifiiedaprope,
Date: V J ) l
SUPPLE'NdENTAL ENTFOR�4ATIOI\I REQUIRED
_
'
�
T"kEL =
OVERT$F COUR'7'ER p,:fK.
CJ
uM 1 .
�
= a.�
ASA7fJR� .J-Ya
w
P M4pp_2011. doc revised 03116111
SMOKE / CARBON MONOXIDE ALARMS
OWNER CERTIFICATE OF COMPLIANCE
COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISION
10300 TORRE AVENUE - CUPERTINO, CA 95014-3255
081777-3228 - FAX 14081 77 ITTA * h"iftfin fnicuarVann or
Permit Noe '1-N—Ld6—,a -3
Address ge 110A a CaPe,4-'�s1'410, CA #ofAlarms Smoke: CarbonMonoxide:
PURPOSE
This affidavit is a self -certification for the installation of all required Smoke and Carbon Monoxide Alarms for
compliance with 2013 CRC Section R314, 2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for
inspections are required.
GENERAL INFORMATION
Existing single-family and multi -family dwellings shall be provided with Smoke Alarms and Carbon
Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds
$1000.00, CRC Section R314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon
Monoxide Alarms be installed in the following locations:
AREA
SMOKE ALARM
CO ALARM
Outside of each separate sleeping area in the immediate vicinity of the
bedroom(s)
X
On every level of a dwelling unit including basements
X
X
Within each sleeping room -
X
Carbon Monoxide alarms are not required in dwellings which do not contain fuel -burning appliances and that
do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with
CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal.
Power Supply: In dwelling units with no commercial power supply, alarm(s) may be solely battery operated.
In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do
not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl
space. Refer to CRC Section R314 and CBC Sections 907.2.11A and 420.6.2. An electrical permit is required for
alarms which must be connected to the building wiring.
As owner of the above -referenced property, I hereby certify that the alarm(s) referenced above has/have been
installed in accordance with the manufacturer's instructions and in compliance with the California Building
and California Residential Codes. The alarms have been tested and are operational, as of the date signed
below.
I have read and aaree to comDiv with the terms and conditions of this statement
Owner (or Omer Agents) Name:
�Osbb,
,TAe t-1 Soma
Signature ............... .Date.
Contractor Name:
Signature......... -- .................................................. Liel ...................................... Date:................... 4
Smoke and COform.doc revised 03118114
Owner Name
WATER -CONSERVING PLUMBING FIXTURES
OWNER CERTIFICATE OF COMPLIANCE
COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISION
10300 TORRE AVENUE - CUPERTINO, CA 95014-3255
(408) 777-3228 ► FAX (408) 777-3333 - buildinnOlcuaertino.oro
"i0D Permit No �-�-�L
Address _ 1 511 a t CiLperflfho, C
1. Is your real property a registered historical site?
❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the forth and sign bottom of form.
d No Go to Question 2.
2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its
plumbing, installation of water -conserving plumbing fixtures is not technically feasible?
Yes Civil Code Sections 1101.1 through 1101.8 do not apply.
El The licensed plumber's certification has been provided to the Building Division.
Skip the rest of the form and sign bottom of form.
No Go to Question 3.
3. Is water service permanently disconnected for your building?
El Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form.
CA No Go to Question 4.
4. Is your real property built and available for use or occupancy on or before January 1,1994?
❑ No My real property is built and available for use or occupancy after January 1, 1994.
Civil. Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form.
Cif Yes My real property is built and available for use or occupancy on or before January 1,1994.
Civil Code Sections 1101.1 through 1101.8 apply. Check one of the three following statements and sign
bottom of form..
5. Vease check ONE of the following:
My property is a single-family residential real property. See Civil Code Section 1101.4.
On and after January 1, 2014, building alterations or improvements shall require all non -compliant plumbing fixtures
to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non-
compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless of whether
property -undergoes alterations or improvements).
11 My property is a multifamily residential real property. See Civil Code Section 1101.5..
On and after January 1, 2014, specified building alterations or improvements shall require non- compliant
plumbing fixtures to be replaced with water -conserving plumbing fixtures..
On or before January 1, 2019, all non -compliant plumbing fixtures shall be replaced with water -
conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or
improvements).
Nly property is a commercial real property. See Civil Code Section 1101.5.
On and after January 1, 2014, specified building alterations or improvements shall require non- compliant
plumbing fixtures to be replaced with water -conserving plumbing fixtures.
On or before January 1, 2019, all non -compliant plumbing fixtures shall be replaced with water.- conserving
plumbing fixtures throughout the building (regardless of whether properly undergoes alterations or improvements).
I, as the owner or owner's agent of this property, certify under penalty of perjuty that non -compliant plumbing fixtures will be
replaced prior to date specified above with water -conserving plumbing fixtures in accordance with Civil Code Sections. 1101.1
through 1101.8, the current California Plumbing Code and California Green Building Standards Code, and manufacturer's
installation requirements, and that the water: conserving plumbing fixtures comply with the requirements as indicated in the
table on the followina vap-e.
j Owner or Owner Agent's Signature: Date: (t1 rLrf M_
T7nnn rmm�lPtino and clan nv this f ertificate nlence return it tdze. Building Division in order to final your building nermit.
SB407 2015.doc revised 08126115
PHOTOVOLTAIC SYSTEM 2.34KW DC
SONG RESIDENCE
21541 REGNART RD.,
CUPERTINO. CA 95014
PL7 FLANS HECK BY
RECEI a - -
BA. 3
;. PL.ANN G ®EPT
CUPERTINO
S
I PROJECT DATA I GENERAL NOTES I rota iimLii -I-C7IENEIL) uN,/ARARTMENT I
PROJECT
ADDRESS:
OWNER:
CONTRACTOR:
DESIGNER:
21541 REGNART RD.,
CUPERTINO, CA 95014
JAE MAHN & CABIO SONG
21541 REGNART RD.,
CUPERTINO, CA 95014
408-446-1557
WEST COAST SOLAR INC.
SCOPE: 2.34kW DC ROOF MOUNT
SOLAR SYSTEM WITH 9
HYUNDAI 260 PV
MODULES AND A 9
ENPHASE MICRO
INVERTERS - M-215.
APN
LOT AREA:
LIVING AREA:
018-370-012-9
8,200 SQ.FT.
1,764 SQ.FT.
1. ALL COMPONENTS ARE UL LISTED AND CEC CERTIFIED, WHERE WARRANTED.
2. THE SOLAR PV SYSTEM WILL BE INSTALLED IN ACCORDANCE WITH ARTICLE 690 OF THE 2013 CEC AND 2013 CBC.
3. WHERE METALLIC CONDUIT CONTAINING DC CONDUCTORS IS USED INSIDE THE BUILDING, IT SHALL BE IDENTIFIED AS
"CAUTION: SOLAR CIRCUIT" EVERY 1 OFT.
4. A DC DISCONNECTING MEANS SHALL -BE INSTALLED AT A READILY ACCESSIBLE LOCATION EITHER OUTSIDE OF THE
BUILDING OR STRUCTURE OR INSIDE NEAREST POINT OF ENTRANCE OF THE SYSTEM CONDUCTORS AS PER SECTION
690.14 OF THE CEC.
5. HEIGHT OF THE INTEGRATED AC/DC DISCONNECT SHALL NOT EXCEED 6'-7" PER NEC CODE 240.24.
6. A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH CEC 690.47 AND 250.50 THROUGH 60 AND 250-166 SHALL BE
PROVIDED.
PER CEC GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND BONDED TO THE SERVICE
ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE OR INADEQUATE A SUPPLEMENTAL GROUNDING ELECTRODE
WILL BE USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT. GROUND ROD WITH ACORN CLAMP.
GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO LARGER THAN #6 AWG COPPER
AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE
FOR A COMPLETE SYSTEM.
7. PHOTOVOLTAIC MODULES ARE TO BE CONSIDERED NON-COMBUSTIBLE.
8. PHOTOVOLTAIC INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING. MECHANICAL, OR BUILDING ROOF VENTS.
THE SMOKE ALARMS SHALL BE INSTALLED OR VERIFY TO ENSURE THE SMOKE ALARMS ALREADY EXISTING WHEN
ALTERATION OR REPAIR TO GROUP R-30CCUPANCY EXCEEDS $1,000 CRC R314.6.
A. ON THE CEILING OR WALLS OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF BEDROOMS
B. IN EACH ROOM USED FOR SLEEPING PURPOSES,
C. IN EACH STORY WITHIN A DWELLING UNIT, INCLUDING BASEMENTS BUT NOT INCLUDING CRAWL SPACES AND
UNINHABITABLE ATTICS.
D. ALL SMOKE ALARMS SHALL BE LISTED IN ACCORDANCE WITH UL217 AND INSTALLED IN ACCORDANCE WITH THE
PROVISIONS OF THIS CODE AND THE HOUSEHOLD FIRE WARNING EQUIPMENT PROVISIONS OF NFPA 72. SYSTEMS AND
COMPONENTS SHALL BE CALIFORNIA STATE FIRE MARSHAL LISTED AND APPROVED IN ACCORDANCE WITH CA CODE OF
REGULATIONS, TITLE 19, DIVISION1 FOR PURPOSE FOR WHICH THEY ARE INSTALLED.
CARBON MONOXIDE ALARMS IF NOT ALREADY EXISTING ARE REQUIRED TO BE INSTALLED WITHIN A DWELLING WHEN
THE VALUATION OF AN ADDITION, ALTERATION OR REPAIR TO GROUP R-3 OCCUPANCY EXCEEDS $1,000 CRC R315.2
CARBON MONOXIDE ALARMS ARE REQUIRED AT THE FOLLOWING LOCATIONS:
A. ON THE CEILING OR WALLS OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF BEDROOMS
B. ON EACH STORY WITHIN A DWELLING UNIT, INCLUDING BASEMENTS.
C. THE CARBON MONOXIDE ALARMS SHALL BE LISTED AS COMPLYING WITH THE REQUIREMENTS OF UL 2034. CARBON
MONOXIDE DETECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THIS CODE, THE CURRENT EDITION OF NFPA 720
"STANDARD FOR THE INSTALLATION OF CARBON MONOXIDE (CO) DETECTION AND WARNING EQUIPMENT" AND THE
MANUFACTURER'S INSTALLATION INSTRUCTIONS PER 2010 CRC SECTION R315.3.
-V-PL7!y I V
A P P.R V'E re 1, �.
I 4,oGc of p(ar�E,, i�pecifaiayi'✓�T t e kept$,h�
;cab sit dGri'nc ccm5trttuctior� ,,l.t"is unlawful to makelGarr
flall�eS ,OC al,tcrfr}�et$; (Jtl°54rrilC, QCmtO C�e1l.it
till eflom,x�v'th, ura, val frth'`h the- ull t7ff
_ I 'The of this pia' n6 seclticat,onsILI1(
he.neici top nit or, to':"an apprg a! of the .violation
any rO.islc ;ifny CF,
v Or: Ir��rcState Law
�e"� •�
DATE
�EtR1tT_
SHEET INDEX I
PV-1: COVER SHEET
PV-2: SI p PV-3: R iiq€ . rP RTNN
PV-4: Fly' III �R,01 N QUII>din jo rP17i�
PV-5: S ' DIAGRAM ®Q c,
PV-6: SEDULE
SPA: MODU ESP CP MAR �� 6t�
SP-2: I E P C
SP-3: RACIPIV9 .FOR CODE COMPLIANC
SP-4: STAND FF SPEC.
SP-5: GROUN6.By: ��yd
CODE REFERENCES
PROJECT TO COMPLY WITH THE FOLLOWING:
CALIFORNIA CODE OF REGULATIONS, TITLE 24
2013 CALIFORNIA BUILDING CODE (CBC)
2013 CALIFORNIA MECHANICAL CODE (CMC)
2013 CALIFORNIA PLUMBING CODE (CPC)
2013 CALIFORNIA ELECTRICAL CODE (CEC)
2013 CALIFORNIA ENERGY CODE
INSTALLATION TO COMPLY WITH ARTICLE 690'OF
THE 2013 NEC.
'30�� p{.
LO
Q
U
Om I_
O I;
N I I
m
oZ CD
Q
O
mUI
LL. I �
Ld CD0
if
f
F rn -
US M
II j t
co � i'p4rim
z ,.,.-
W
In
v
N
0
w
Z
r N
W cM
1�o
® N
0
o
I—
coo :
5)
w z
000
�E0
C7 0
"04 Qz
O
N U Q
U-
0
a
a
REVISIONS
DRAWN BY:
LK/AB
DATE:
3/15/2016
SCALE
SHEET TITLE:
TITLE SHEET
SHEET:
PV-1
116.00'
\
\
/
N ° ❑ /
ARRAY
\ 0 18" MIN. 2 MODULES
\ 0 850 AZIMUTH /
\ 3' MIN. 180 TILT
18" MIN. /
\ O /
°0 /
(E) 100A SUB- PANEL \ 0 0
(LOCATED INSIDE THE GARAGE) o /
\
/
o /
ARRAY 1
7 MODULES ® /
2650 AZIMUTH \
180 TILT o 0
(E) 100A
MAIN SERVICE PANEL
1 RFVIGI(1NS 1
CUPERTINO
a
Tq it
.. Building Department W
0
201
REGNART RD,
REVIEWED FOR CODE COMPLIANCE
Revit%.vved By,
z®®®®® 4
DRAWN BY:
LK/AB
(E) 100A SUB -PANEL
MAIN PV DISCONNEC-
(E) 100A MAIN SERVICE PANEL
KEY / COMPONENTS
SYMBOL
DESCRIPTION
NEMA 3R JBOX
ENPHASE MICRO INVERTERS - M-215
— — —
4" EMT CONDUIT
PV MODULE
GENERAL NOTES:
1. 18 DEGREE
2. 2X4 DF TRUSS @ 24" O.C.
3. COMPOSITION SHINGLE
4. (9) HYUNDAI 260 PV MODULES
5. (9) ENPHASE MICRO INVERTERS - M-215
6. IRONRIDGE XR-10 RAIL
7. IRONRIDGE FLASHFOOT
8. WEEB CLAMPS & LUGS FOR PV GROUNDING
CUPERTINO
FF..
80ding Depatnent
1
MAR
20%
REVIEWED FOR ;CEDE COMPLIANCE
Reviewed BV:
_ , �lelv
I REVISIONS I
'11"'
11
ommoommm
DRAWN BY:
LIVAB
LEGEND:
OIRONRIDGE FLASHFOOT
1 SPAN -6FT. TO MEET
ASCE 7-10 WITH WIND
SPEED AT 110 MPH
ZONE 1 (TYPICAL)
IRONRIDGE FLASHFOOT
SPAN -4FT. TO MEET
OASCE 7-10 WITH WIND
SPEED AT 110 MPH
ZONE 2 (TYPICAL)
LOAD CALCULATION
System Size
2.34 kw DC
.Module:
H undai 260
Modules in array
9
Modul e weight-[ bs.
46.7
Total module weight
420.30
Racki ng Ibs./module
1
total racking weight-Ibs
9
TOTAL ARRAY WEIGHT
429.30
MODULE AREA
17.485
TOTAL ARRAY AREA
157.365
Lbs./S .ft. (less than 5 - OK)
2.73
number of vertical supports
15
Lbs. per support (less than 45 -OK)
28.62
FRAMING CROSS SECTION
SCALE: N.T.S.
"' ;u:-_�
,
sl�� `'E T' %d��{'
Bull LII1b QV.nL?rt-jig
� r'1n t l� 1 ICnt
PV MODULE REVIEWED F®F' �,� ):9 COMPL ANCE
eviewet9 By: } �
IRONRIDGE XR-14
RAIL
COMPOSITION SHINGLE IRONRIDGE
ROOFING I FLASHFOOT
5/16"x3" LAG
SHEATHING SCREWS ON 2.5"
I MIN. EMBEDMENT/
2X4 DF TRUSS
@ 24" O.C.
— — — — — — — — — — — — — — — — — -
MOUNTING DETAIL
SCALE: N.T.S.
1 REVISIONS 1
iiiiiiii
com
A
o
mmm
DRAWN BY:
LK/AB
EXISTING AC CURRENT
(E)100A/240V (E)100A/240V
MAIN SERVICE PANEL I SUB -PANEL
NEUTRAL
O�
(N) 15A 1P
0 MONITORIN DEVICE
9
BREAKER
(E)100A
MAIN DISC.
BREAKER
GROUND GROUND
(N)15A 2P�
SOLAR BREAKER
AC CURRENT
1 - 10/3 ROMEX (IN ATTIC)
1 -#6 GROUND
AND/OR
2-#10 THWN-2 CONDUCTORS
2-#10 THWN-2 NEUTRAL
1 -#8 THWN-2 GROUND
IN 1 -'/ CONDUIT
WIRE RUN NOT MORE THAN 100'
J-BOX
NEMA 3R
9 HYUNDAI 260 MODULES
AND
9 ENPHASE MICRO INVERTERS - M-215 INVERTERS
BRANCH CIRCUIT #1 -9 MODULES AND MICROINVERTERS
e■C
e
C
e■C
PV SOURCE CIRCUITS
AC CURRENT o��g
1 - ENPHASE INVER TRUNK CABL c` �, a INO
1 -#6 GROUN-9 � �a
NOTES:
1. 9 HYUNDAI 260 PV MODULES
2. 9 ENPHASE MICRO INVERTERS - M-215 INVERTERS.
3. PV SOURCE CIRCUIT(S) ARE TO BE SUNLIGHT -RESISTANT ENPHASE TRUNK CABLE AS PERMITTED BY CEC 690.31(B).
4. ALL DIRECT CURRENT CIRCUITS ARE TO BE INSTALLED IN METAL RACEWAY FROM THE POINT OF PENETRATION OF THE SURFACE
OF THE BUILDING OR STRUCTURE TO THE MAIN SERVICE PANEL AS MANDATED BY CEC 690.31(E). THERE ARE NO DIRECT CURRENT CIRCUITS PAST THE MODULE TO INVERTER CONNECTION.
5. WEATHERPROOF J-BOX - NEMA 3.
6. (E) 100A MAIN SERVICE PANEL WITH 100A MAIN BREAKER TO SUPPLY (E)100A SUB -PANEL. ON SUB -PANEL- ADD ONE(1) 2POLE 15A FOR SOLAR BREAKER.
7. ALL WORK SHALL COMPLY WITH THE 2013 CALIFORNIA ELECTRICAL CODE (C.E.C.) AND ALL OTHER LOCAL CODES AS APPROVED BY THE AUTHORITY HAVING JURISDICTION.
REVIEWED FOR r,()MPLIANCE
"'" ' h4_�/
(���i�vdecl $y:
1 PFvicinmo 1
iiiiiiii
m00
A
000m
DRAWN BY:
LK/AB
,� ��i�Tt�o�rc�Q sotAR Q
QUR(N�*D= 1��tT OESp r
(STICKER TO BE LOCATED ON O
CONDUIT WITH DC CURRENT
EVERY 4' HORIZONTALLY OR
10' VERTICALLY AND 1' FROM
EACH SIDE OF A BEND)
LABEL SCHEDULE
m
(STICKER LOCATED
INSIDE PANEL
NEXT TO PV BREAKER)
(STICKER LOCATED
INSIDE PANEL
BELOW PV BREAKER)
SUB -PANEL
O O
10 11
METER
MAIN
SERVICE
Og PANELZ,,
C Lq P EIRT I N 0
BUildim3 Dapa +i e if
M � 5 2016
REVIEWED FOR CODE COMPLIANCE
Reviewed By:
1 RFVISIf]NS I
DRAWN BY:
LK/AB
2.34 kW DC (STC)
9—HYUNDAI 260 MODULES &
9—ENPHASE MICRO INVERTERS - M-215 INVERTER
C U P E___ R7, I N 0
Building, D^wartment
BAR � 5 20
REVIEWED FOR GODS COMPLIANCE
Reviewed BV:
ARRAY 1
7 MODULES
>
ARRAY 2
2 MODULES
2650 AZIMUTH
850 AZIMUTH
180 TILT
180 TILT
I RFVISIONS 1
11111111
lommommmm
DRAWN BY:
LK/AB
www.hhi-green.com/solar
colco
5O�lnlf-:] Madu0;
Hyundai Heavy Industries was founded in 1972 and is a Fortune 500 company. The company employs more than 48,000 people, and has a global
-leading 7 business divisions with sales of 60.2 Billion USD in 2012. As one of our core businesses of the company, Hyundai Heavy Industries is
committed to develop and invest heavily in the field of renewable energy. _ -
Hyundai Solar is the largest and the longest standing PV cell and module manufacturer in South Korea. We have 600 MW of module production
capacity and provide high -quality solar PV products to more than 3,000 customers worldwide. We strive to achieve one of the most efficient PV
modules by establishing an R&D laboratory and investing more than 20 Million USD on innovative technologies.
4 mm' (12AWG) cables with polarized weatherproof connectors,
IEC certified (UL listed) Length 1.0 m (39 41
IP68 e
Pedroo weath r fIECcertifiUL,listed
m
3 bypass diodes to prevent power decrease by partial shade
Front High transmission low -von tempered glass 2 8 min (01 i"j ,
Encapsularit EVA Back Sheet Weatherprooffilm _.nllyll��
Clear anodized aluminum alloy type 6063
High Quality
• IEC 61215 (Ed.2) and IEC 61730 byVDE
• UL listed (UL 1703), Class C Fire Rating
• Output power tolerance +3/-0 %
• 150 9001:2000 and ISO 14001:2004 Certified
• Advanced Mechanical Test (5,400 Pa) Passed (IEC)
/ Mechanical Load Test (40 Ibs/ft') Passed (LIQ
• Ammonia Corrosion Resistance Test Passed
• IEC 61701 (Salt Mist Corrosion Test) Passed
/
East and Inexpensive Mounting
� w
• Delivered ready for connection
• IEC (UL) certified and weatherproof connectors
t.
.;
• Integrated bypass diodes
Limited Warranty
• 10 years for product defect
• 10 years for 90 % of warranted min. power
• 25 years for 80 % of warranted min. power
X Important Notice on Warranty
The warranties apply only to the PV modules with Hyundai Heavy Industries Co., Ltd''s
logo (shown below) and product serial number on it.
E HYU N DAI
�
e r�� Eo ` s `tl i ` - HEAVY INDUSTRIES CO.,LTD.
Electrical Characteristics
Multi -crystalline Type
Nominal output (Pmpp) W 250 255 260
v _ _
Voltage at Pmax (Vm V 30 9 _ - 31 0 31.1
9 - - PP) - �.._ ..
Current at Pmax (Impp) A _ 8.1 8.2 8.4
Open circuit voltage (Voc) V 37 4 37 6 37.7
T ',
r _ ._ .. _ ......,_.- _
Short circuit current (Isc) A 8.7 8.8 8.9
r?Output Tolerance " % . ,, +3/
No. of cells & connections PCs 60 in series
I11Cell type _ 6 Nlulu crystalline silicon (Hyundai cell Made in KoPea)
m:.. ,.x _,._:._ _ ...._..._ ,. _,. r ._...._ .:. ...:._.
Module efficiency % 15.3 15.6 15.9
Tem eratur'e coefficient of Pm 043 j
Temperature coefficient of Voc %/K 0 32 0 32 0 32
r a.
Temperature coefficient of lsc %/K O'048 0 048 _. _ 0. 048y
>J.
X All data at STC (Standard Test Conditions). Above data maybe changed without prior notice.
Mono -crystalline Type
Nominal output (Pmpp)
W
260
265
270
Voltage at Pmax (Vmpp)
V
31 1
31 3
31 4 '
Current at Pmax (Impp)
A
8.4
( 8.5
8.6
v
Open circuit voI age,(Voc)
v
V
37 9
I `
38 1
_. ..
Short circuit current (Isc)
A
8.9
9.0
9.2
Output tolerance
... _ ...
--PCs
+3/0
�"
No. ofcells&connections
60inseries
Cell type �-
6 Mono crystalline silicon (Hyundai cell Made mKorea)-
Module efficiency
%
15.9
16.2
16.5
Temperaturec ec ent
_77
0.4
0.4 5
Temperature coefficient of Voc
%/K
-0.33
0.33
-0.33
Tem er -1- 'coeffi n I
a e cie t of sc .
W ....,:.
�,., ,:
0 i:- , ..
_.. , k K
,, .:.
, : .,. -0.032
_ .
; '
- 0.032 , - . " ;:
: .,:
. �. -, ..0.032 w
XAll data at STC (Standard Test Conditions). Above data maybe changed without prior notice
Module Diagram
Installation Safety Guide
(unit: mm, inch) I-V Curves
C-e¢t[A]
•
um.wms 2VC
4X07{11 75(03') 5
T4.WCABLE&
HOLES'. . s Le' RC%
8Dtm4Tie-07 SL0T �e 'L1zG7pl(I I L1GIe�. d�..I Lllllvr
4rnWCABIE& 8 032OMMOR - CONECTOR
00 S 1, 10 15 304{`JI 3¢ gpp3�55 '{4¢ ds
4A A, k, ..
ea
GROUND MARK
C 253 (9
• Only qualified personnel should install or perform maintenance.
• Be aware of dangerous high DC voltage.
• Do not damage or scratch the rear surface of the module.
• Do not handle or install modules when they are wet.
'DETAIL B
a
8(0.71).
- iMoo0W00W,1.9
60tz49L110.431REDIDIq YPLlAN
�Revl
' -•- _
-'
sECT19N C{
V°ItzgeM
j it fa, rri h 46Ct2
o. A:Lr9-40-85'C
DC 1 000 V (IEC)
as�g1"'1" ,; 3a a 1 15 A
Sales & Marketing
Punted o Fsccemeea, ' 21 FI., Hyundai Bldg., 75, Yul ok-ro, Jon no- u Seoul 110-793, Korea
eco-friendb, paper Y 9•. 9 9 9 .
rsC Tel:+82-2-746-8406,7422,8525 Fax:+82-2-746-7675
[ Printed Date: January 20141
HYU N DAI
HEAVY INDUSTRIES CO.,LTD.
�:Iy�IC�rili•C�
11111111
am00asee
DRAWN BY:
LK/AB
Enphase Microinverter
Model M215
M215 Specifications
Enphase M215'Microinverter Parameters
Topic . Unit Min Typical Maxi
DC Parameters
MPPT voltage range
V
22
36
Operating range
V
16
36
Maximum DC input voltage
V
45
Minimum / Maximum start voltage
V
22
45
Maximum DC input short circuit current
A
15
Maximum DC input current
A
10.5
Ground fault protection
mA
1000
Maximum input source backfeed current to input source
A
0
`Enphase M215 Mit:roinverter Parameters f
T.o'pic Unit Min Typical Max
i AC Parameters i
Rated (continuous) AC output Power (-40 to+65°C)
W __
215
Output power factor
0.96
0.99
1
Nominal AC output voltage range
240 VAC (split phase)
208 VAC (three phase)
Vrms
Vrms
211
183
240
208
264
229
Extended AC output voltage range
240 VAC (split phase)
208 VAC (three phase)
Vrms
Vrms
206
179
269
232
Maximum AC output current at nominal voltage
240 VAC (split phase)
208 VAC (three phase)
Arms
Arms
0.9
1.0
Nominal AC output frequency range
Hz
59.3
60
60.5
Extended AC output frequency range
Hz
57
1 60
60.5
Maximum AC output over current protection device
A
20
Maximum AC output fault current 8 duration
Arms/cycles
1.05 Arms over 3 cycles
1.04 Arms over 5 cycles
High AC Voltage trip limit accuracy
%
±2.5
Low AC Voltage trip limit accuracy
%
±4.0
Frequency trip limit accuracy
Hz
±0.1
Trip time accuracy
ms
±33
Miscellaneous Parameters' - -- t
Maximum inverters per 20 amp AC branch circuit
240 VAC (split phase)
208 VAC (three phase)
17
25
Peak inverter efficiency
%
96.3
CEC weighted efficiency
%
96.0
Static MPPT efficiency (weighted, ref EN 50530)
%
99.6
Total Harmonic Distortion
%
3.0
5
Operating temperature range (internal)
°C
-40
85
Ambient temperature range
°C
-40
65
Night Tare Loss
mW
46
Storage temperature range
°C
-40
65
Enphase M215 Microinverter Parameters
Topic Unit, Min Typical Max j
Features and Specifications
Compatibility
Pairs with most 60-cell PV modules
Dimensions not including mounting bracket (approximate)
17.3 cm x 16.4 cm x 2.5 cm (6.8" x 6.45" x 1.0")
Weight
3.5 Lbs (1.6 Kg)
Enclosure environmental rating
NEMA 6
Torque specifications for fasteners
6 mm (1/4") mounting hardware: 5 N m (45 to
(Do not over torque.)
50 In-Ibs)
• 8 mm (5/16") mounting hardware: 9 N m (80
to 85 in-Ibs)
Torque specification for 10/32 ground cleat
2 N m (20 to 25 in-Ibs)
(Do not over torque.)
Cooling
Natural convection: no fans
Communication
Power line
Standard warranty term
http://enphase.ggm/warranty
Compliance
UL1741, IEEE1547, FCC Part 15 Gass B
CAWCSA-C222 NO. 0-M91, 0.4-04, and 107.1-01
Integrated DC disconnect
The DC connector has been evaluated and
approved for use as the load -break disconnect
required by the NEC.
Integrated AC disconnect
The AC connector has been evaluated and
approved for use as the load -break disconnect
required by the NEC.
Engage Cable Specifications
Specification '. Value
System temperature range (ambient)
-40°C to +65°C (-40°F to 149°F)
Cable temperature rating
90°C Dry 190°C Wet'
Cable type
TC-ER
Cable conductor insulator rating
THWN-2
Environmental protection rating
IEC 60529 IP67
UV exposure rating: terminator, engage coupler, and drop
connector body
UL 746 C, F1
Sunlight resistance (cable)
UL 1277
Compliance
UL486A/B, UL 514C, UL6703, UL 9703, IEC
60529 IP67, CAN/CSA 22.2 No. 21, 182.3
Conductor size
12 AW G
Cable diameter
1.25 cm (0.49")
Minimum bend radius
4.75 inches (12 cm)
Drop connector dimensions
11.8 cm0;cm32. C
(4.64" xj2 36 z 1=25")
Terminator capdimensions
3.6 cm `t` ter - 5. c tall 1.4" x 2" l s
�u a, ( )
ER d INO
ing D^pertnent
Ra-VIEVVED FOR C ;'DE COMPLIANCE
Reviewed By: ^' hAlaw
1 RFVIGIr1NG 1
�0000000
DRAWN BY:
LK/AB
Z IR®NRIDGE
Over their lifetime, solar panels experience countless
extreme weather events. Not just the worst storms in years,
but the worst storms in 40 years. High winds capable of
ripping panels from a roof, and snowfalls weighing
enough to buckle a panel frame. _
XR Rail Family I XR Rail Family
XR Rails are the structural backbone preventingIS SOON%
these results. They resist uplift, protect
At7wam
against buckling and safely and efficientlyASN
spanning capability
Their superior
transfer loads into the building structure
s
P g abilit P Y rN
requires fewer roof attachments,
reducing the number of roof
penetrations and the amount
of installation time.
15
Force -Stabilizing Curve
w
Sloped roofs generate both vertical and lateral
n
forces on mounting rails which can cause them
s
to bend and twist. The curved shape of XR Rails
$
is specially designed to increase strength in both
directions while resisting the twisting. This unique
feature ensures greater security during extreme
`.
weather and a longer system lifetime.
Compatible with Flat & Pitched Roofs
- XR Rails are: IronRidge offers
compatible with a range of tilt leg
FlashFoot and options for flat
other pitched roof roof mounting
attachments. applications.
Corrosion -Resistant Materials
All XR Rails are made of marine -grade
aluminum alloy, then protected with an
anodized finish. Anodizing prevents surface
and structural corrosion, while also providing
a more attractive appearance.
The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific
design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match.
XR10
XR10 is a sleek, low -profile mounting
rail, perfectly matched to regions
without snow. It achieves 6 foot spans,
while also staying light and economical.
6'spanning capability
Moderate load capability
Clear anodized finish
Internal splices available
Rail Selection
XR 100
XR 100 is the ultimate residential
mounting rail. It supports a range of
wind and snow conditions, while also
maximizing spans.
8'spanning capability
Heavy load capability
Clear & black anodized finish
• Internal splices available
XR1000
XR1000 is a heavyweight among
solar mounting rails. It's built to handle
extreme climates and spans 12 feet or
more for commercial applications.
• 12' spanning capability
Extreme load capability
Clear anodized finish
Internal splices available
The following table was prepared in compliance with applicable engineering codes and standards. Values are
based on the following criteria: ASCE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean
Building Height of 30 ft. Visit IronRidge.com for detailed span tables and certifications.
100
120
I _,
None
140
XR10 XR100 f ;,� XR1000
160
100
r'-
'I N
= i'.r ' �i�il�illtla Ld ��4l
L11
120
_� ,
14020
1NON10-20
160•
so
100
Reviewed BY:
160
40
100
t
160
t ;
50-70
160
qi
80-90
160
i
�1111111
�00000�0
DRAWN BY.
LK/AB
��L_""� IRON RIDGE
IronRidge FlashFootTM is an all -in -one solar mounting
product for composition shingle roofs that eliminates the
need for separate standoffs, flashings, and L-feet.
FlashFoot incorporates a number of structural and
waterproofing features to securely attach IronRidge
Rails to roof structures, while also protecting against
water intrusion and weather damage.
Load Distribution Plate
A solid metal plate below the L-foot
increases the FlashFoot's structural
strength and prevents any deformation
of the flashing during installation.
Certified compliant
IAPMp with IBC and IRC.
ES
FlashFootTM
Dual Mechanical Seal
At the core of the FlashFoot, a pre -installed
r rubber bushing forms a dual mechanical
seal, with its exterior compressed against
fly the cavity of the L-foot and its interior tightly
wrapping around the shaft of the lag bolt.
1
r
Water Shedding Design
A wide flashing layer combined with an
elevated sealing platform maximizes the
FlashFoot's water shedding ability.
Installation Overview
Tools Required: tape measure, chalk line, stud finder, roofing bar, caulking gun with an approved sealant, drill
with 1 /4" bit and 1 /2" socket.
Locate rafters and snap vertical and horizontal lines
to mark locations of flashings. Drill 1/4" pilot holes,
then backfill with an approved sealant.
Line up pilot hole with flashing hole and insert lag
bolt through bonded washer, L-Foot, and flashing.
Tighten lag bolt until fully seated.
Slide flashing, between 1 st and 2nd course, so the
top is at least 3/4" above the edge of the 3rd course
and the bottom is above the edge of the 1 st course.
The FlashFoot is now installed and ready for
IronRidge Rails. With provided L-foot fasteners pre -
loaded into rails, drop rails into open L-foot slots.
�r ` CLl�'�R p,�
a-3A r t'` r ,
TestingCertification�pa
Ru,ldirtg Dcpe l
FlashFoot is certified for compliance with the International Building Codes (IB &nte�r itional�f�esjdenina
Codes (IRC) by IAPMO-ES. Mechanical testing conformed to the standard for Tes �Ing and Analysis of Jois
Hangers and Miscellaneous Connectors (EC002-2011), and rain testing conforF,I_GgrJtR0g-I- nc �rw ter�SE ��r�PLB
Laboratory Standard for Gas Vents (UL 441-96 Section 25).
�.
Revit�vvdeti FF3Y:
Douglas Fir, Larch .50 798
Douglas Fir, South
I .46
705
Engelmann Spruce, Lodgepole Pine (MSR 1650 f & higher)
46
705
Hem, Fir
.43
636
Hem, Fir (North)
.46
705
Southern Pine
.55
921 I
Spruce, Pine, Fir
.42
616 ,
Spruce, Pine, Fir (E of 2 million psi and higher grades of MSR and MEL)
.50
798
LO
,It
m
a
°
0
o
;
° L0
~o
W CM I`
a
m J
w �
0
rlm I
j
t��J
20
LU
z Imo-,
J v
w
Ln
0
LU
Z
� � N
LLI cM 0
N
�Lno
rn mQo
U
co, Uc
LUz
�o06
�— 1E o
C7 Q
�_ Qz
®�
NUQ
�LL
O
a
a
REVISIONS
F
a
U
0
Q
0
®®®®
1Hi1WN BY:
LK/AB
DATE:
SCALE:
SHEET ME-
FLASHFOOT
SPEC.
SHEET:
S 4
M
,Z� IRONRIDGE
Simplified Grounding
For Greater Safety & Lower Cost
Traditionally, solar modules are grounded by attaching
lugs, bolts or clips to the module frame, then connecting
these to a copper conductor that runs throughout the
array. This process adds time and cost to the installation,
and often results in improper grounding, creating
significant long-term safety risks.
The IronRidge Integrated Grounding System solves these
challenges by bonding modules directly to the mounting
rails. This approach eliminates separate module
grounding hardware, and it creates many parallel
grounding paths throughout the -array, providing
greater safety for system owners.
01
k'
2�
Grounding Strap
R
I Grounding Straps are used to
t
bond rail -to -rail connections.
( They are only required on the
rail with the grounding lug.
1
� S e
Integrated Grounding System
Installation overview
w Install Roof Attachments
1 ' '� • Install appropriate roof flashing and/or standoff for roof type. f 11
--
t I 'tea
• Attach L-Feet to flashing or standoff.
---- -a Prepare Rail Connections
• Insert splice into first rail, then secure with Grounding Strap and p {{
(j self -drilling screw.
' • Slide second rail over splice, then secure with opposite end of �r
o- Grounding Strap and self -drilling screw.C�
Grounding Mid Clamp
Each Grounding Mid Clamp pierces through the
anodized coatings of both the module frame and
the mounting rail to form secure electrical bonds,
which are repeated throughout the array.
Mount & Ground Rails
• Attach rails to L-Feet and level rails.
�`-
• Install one Grounding Lug per row of modules.
• Connect Grounding Lug to grounding conductor. �, y
DO Install Modules & Clamps -
• Install first module using End Clamps and Grounding Mid Clamps. 14t
• Install additional modules using Grounding Mid Clamps. __-
• Finish row with a second pair of End Clamps.
lit GW�,OWN11�",�all ' j��®I®�"' 'resting & Certification
The IronRidge Integrated Grounding
System has been tested and certified to
UL 2703 by Intertek Group plc.
�0
Ail
UL 2703 is a proposed UL standard
for evaluating solar module mounting
,'{s, and clamping devices. It ensures these
devices will maintain strong electrical and
// mechanical connections over an extended
period of time in extreme outdoor
Ir
T environments.
_' The testing process closely mirrors that
of UL 1703, the solar module testing
standard including temperature erature and
Grounding Lug humidity cycling, electrical and mechanical
A single Grounding Lug load testing, and manufacturing quality
connects an entire row g� g q y
of PV modules to the reviews.
grounding conductor.
I B] Module Frame Compatibility
f
A
Any module frames whose parameters are not listed in the
provided table have not bd n i}� -fib ompatibility.�-
�o� n �d
� � r Jllc�l;t, Dapar-
The Grounding Clamp has prove p ; st ii`t grounding 60-cell and
72-cell solar module frames with Gx'co„structlon and!a�rage of a
� I a,,a
anodization thicknesses.
All solar modules listed to UL 170 a%ttl�l t�� `rri��on�stFu tio�t Cl UIPLI 1
within the parameters stated above are mpatible.tivith the
IronRidge Integrated Grounding Systemwlew� y:';
Go to ironridge.00m/ig
Dimension
Range
A
31.Omm - 51.Omm
B
5.08mm (minimum)
1 RFVISICINS 1
�0000��0
oruwra ar:
��, LK/AB