Loading...
B-2016-1619 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO:B-2016-1619 21731 SANTA BELLA PL CUPERTINO,CA 95014-4833(356 22 022) RAYCO ENERGY INC LOS ALTOS,CA 94024 OWNER'S NAME: YIN VICTOR HAO-EN AND KUEI CHUN DATE ISSUED:03/24/2016 OWNER'S PHONE: PHONE NO:(510)646-7566 LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO: License Class C-46 Lic.#1001179 Contractor RAYCO ENERGY INC Date 02/28/2017 X BLDG ELECT _PLUMB I hereby affirm that I am licensed under the provisions of Chapter 9(commencing MECH X RESIDENTIAL_COMMERCIAL with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. JOB DESCRIPTION: INSTALL(l)ROOFTOP MOUNTED SOLAR PV(3.64 KW)-14 I hereby affirm under penalty of perjury one of the following two declarations: PANELS 1. I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 ofthe Labor Code,for the performance of the work for which this permit is issued. i. I have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$7000.00 APPLICANT CERTIFICATION certify that I have read this application and state that the above information is correct.I agree to comply with all city and county ordinances APN Number: Occupancy Type: and state laws relating to building construction,and hereby authorize 356 22 022 representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save indemnify and keep harmless the City of Cupertino against liabilities,judgments,costs,and expenses which PERMIT EXPIRES IF WORK IS NOT STARTED may accrue against said City in consequence of the granting of this permit. WITHIN 180 DAYS OF PERMIT ISSUANCE OR Additionally,the applicant understands and will comply with all non-point source regulations upertino Municipal Code,Section 9.18. 180 DAYS FROM LAST CALLED INSPECTION. 8rignatur _ Date 3/24/2016 Issued by:PAUL O'SULLIVAN Date:3/24/2016 OWNER-BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of the RE-ROOFS: following two reasons: All roofs shall be inspected prior to any roofmg material being installed.If a roof is 1. 1,as owner of the property,or my employees with wages as their sole installed without first obtaining an inspection,I agree to remove all new materials for compensation,will do the work,and the structure is not intended or offered for inspection. sale(Sec.7044,Business&Professions Code) 2. I,as owner of the property,am exclusively contracting with licensed Signature of Applicant: contractors to construct the project(Sec.7044,Business&Professions Code), Date:3/24/2016 I hereby affirm under penalty of perjury one of the following three declarations: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER 1. 1 have and will maintain a Certificate of Consent to self-insure for Worker's - Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. HAZARDOUS MATERIALS DISCLOSURE 2. I have and will maintain Worker's Compensation Insurance,as provided for by I have read the hazardous materials requirements under Chapter 6.95 of the Section 3700 of the Labor Code,for the performance of the work for which this California Health&Safety Code,Sections 25505,25533,and 25534. I will permit is issued. maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the 3. I certify that in the performance of the work for which this permit is issued,I Health&Safety Code,Section 25532(x)should I store or handle hazardous shall not employ any person in any manner so as to become subject to the material. Additionally„should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I Worker's Compensation laws of California. If,after making this certificate of will maintain compliance with the Cupertino M c 1 de,Chapter 9.12 and exemption,I become subject to the Worker's Compensation provisions of the the Health&Safety Code,Section 5 ,2 3 ,and 25534. Labor Code,I must forthwith comply with such provisions or this permit shall l be deemed revoked. Owner or authorized agent: APPLICANT CERTIFICATION Date:3/24/2016 certify that I have read this application and state that the above information is CNSTRUCTION L GANCY correct.I agree to comply with all city and county ordinances and state laws I hereby affirm that there is a construction lending agency for the performance relating to building construction,and hereby authorize representatives of this city of work's for-which this permit is issued(Sec.3097,Civ C.) to enter upon the above mentioned property for inspection purposes. (We)agree Lender's Name to save indemnify and keep harmless the City of Cupertino against liabilities, judgments,costs,and expenses which may accrue against said City in Lender's Address consequence of the granting of this permit. Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal ARCHITECT'S DECLARATION Code,Section 9.18. 1 understand my plans shall be used as public records. Licensed Signature Date 3/24/2016 Professional ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION 10300 TORRE AVENUE•CUPERTINO, CA 95014-3255l�_ 16M eUP:RTI hf0 (408)777-3228 • FAX(408)777-3333•buildinaCa cupertinc.orct PROJECTRESS APN OWNER NAME PHONE _ E-MAIL STREET ADDRESS C Y, STATE,ZI FAX Z111,3l �a�t� �(la L �u �rA-tN �!�- CONTACT NAMEP ONE E-MAIL --k.— . � S --S7z� I N 1 , Lv ¢air r� STREET ADDRESS CITY.STA Z 5�Y♦J t FAX c Z2Z ro lle lle ❑ OWNER ❑ OWNER-BUILDER ❑ Ola'NER AGENT ❑ COIT*IRACTOR El CONTRACTOR AGENT ❑ ARCH�CT ❑ENGINEER ❑ DEVELOPER ❑ 7 ENTANT CONTRACTOR NAh4ELICENSE I>TUh BER LICENSE TYP I BUS.LIC n n COMPANY:NAME E-MAIL I FAX ea Gwcic' STREET ADD S CITY,STATE,ZIP/1 PHONE2212- r 1t` try - Z$ .16C� ARCHITECT/ENGINEER NAME LICENSE NU1 fBER BUS.LIC m COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE USE OF ❑ SFD of Duplex ❑ Multi-Family PROJECT IN WILDLAXTTD PROJECT IN STRUCTURE: E] Commercial URBAN INTERFACE AREA Yes ❑ No FLOOD ZONE 1:1Yes [I NO IP SOLAR PANELS ❑ ELECTRIC VEHICLE•CHARGING STATION ❑ SOLAR WATER HATING ❑ OTHER: FORSOL:4RTAXELS: NUh4BER OF PANELS/UNITS: 4 KILOWATTS(COh1MERCI.AL`ONLY): TOTAL VALUATION: �,0 DESCRIPTION OF WORK S 'V S s ¢n By my signature below,I certify to each of the ollo�i ing: I am the property owner or authorized agent to act on the property oAmer's behalf. I have read this application and the information I have pr ide correct. I have read the.Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state lav,s relating to 1 ing o truction. I authorize representatives of Cupertino to enter the above-identified property for inspection purposes. Signature of Applicant Q Date: TAL INFORMATION REQUIRED RM _ ��OS�R TH1'GOIII�'T'ER '� � s -. ��1..'., �� 1;•3RGE: _ z.—.-tom _ PT14pp 2011.doc revised 03/16111 SHEET INDEX SYMBOL LEGEND ; PV-1 SOLAR LAYOUT Y PV-2 ATTACHMENT DETAILS ,— - ~ + � �� ` f' PV-3 ELECTRICAL LINE DIAGRAM SATELLITE DISH PV-4 PLOT PLAN - PV-5 EQUIPMENT SPECIFICATION SHEETS =- 3222 CASTRO VALLEY BLVD ATTIC VENTS CASTRO VALLEY,CA 94546 NOTES: - -' P: (510)646-7566 MECHANICAL & www.raycoenergy.com -Solar Photovoltaic System to be installed on PLUMBING VENTS CEI V E 8 �iHE D B C46 LICENSE#1001179 residential structure. _ Y -Design complying with the latest edition of CHIMNEY ! R 2, � DATE PROJECT NAME: California Electrical Code, NEC and all local `--- �d�6 MAR ■� ordinances and policies. � � I BY PLANNING DEPTCUPERTINO = ■ �■ -The project has been designed in compliance with SOLAR MODULES �- the CBC section1609 to withstand a minimum 110 i� -- MPH wind load. - =- RE S I D E N C E CSFM _1"' OPY - Per sections R314&R315 within the 2013 3' SETBACKS CE California Residential Code(CRC), it's required that 21731 SANTA BELLA PL smoke alarm and carbon monoxide detectors are MAIN SERVICE PANEL MAIN CUPERTINO, CA 95014 retrofitted into the existing dwelling for permits with repairs or additions exceeding$1,000. O UTILITY METER M -Working distances around the existing electrical equipment as well as the new electrical equipment LOAD CENTER LC COMMUNITY DEV I_OPMENT.DEPARTMENT JURISDICTION: will be maintained in accordance with CEC 110.26 BUILDING DIVISION - CUPERTINO CUPERTINO, CITY OF CPF PV METER PV AF PROVED -This system will not be interconnected until This set of plans anti pecifica.tions MUOT be kept at the approval from the local jurisdiction and the utility is AC DISCONNECT (14) HYUNDAI 215-6 6 LL-S2 - pp � � ® ob site Burin construction. Itis unlav�ul to make any obtained. ). ,, g mJ (14)ENPHASE M215-60-2LL-S22-IG GAS MAIN O changes or alteraiions on samemor to deviate -This system is a utility interactive system with no therefrom,without approval from the Building Official. DRAWING NOTES: storage batteries. The Stamping of this p an and specifications SHALL NOT be,held to permit or tD be an approval of the violation 260W Y1 ///��� �{ MODULE RATED AT: -The Solar Photovoltaic installation shall not of any pr ions o , n 0r4inance or State Law. (SOLAR MODULES HAVE A LASS FIRE RATING) obstruct any plumbing, mechanical or building roof BY. \V1/11�V/1 MULTIPLY BY QTY.OF MODULES: 14 vents. I DATE:- _' PERMIT#_�_ ���. �� ARRAY SYSTEM SIZE: 3.64 kW -When a backfed breaker is the method of utility 177 SYSTEM AZIMUTH: o interconnection, breaker shall not read Line and I 180— 412 Load 3' 23'-5" (20)QTY ATTACHMENT ROOF PITCH: uJ MAIN POINTS @ 72"OC MAX MOUNTING HEIGHT: 2—STORY ORIENTATION OPTIONS ARE PRELIMINARY,AND ARE SUBJECT TO REVISION FOR OPTIMAL USE. DRIVEWAY �'a (� �y ` SOLAR ARRAY LOCATIONS ARE TO BE REVIEWED Joy d : d s ' L« r 11 I AND APPROVED BY OWNER AND/OR ARCHITECT OF LLI ��; Y -- J e m c RECORD TO VERIFY SYSTEM LOCATION FOR o- { o, ' o r 'hVENTILATION OBSTRUCTION AND POSSIBLE tiv Dui din Deipartmenf _ g RELOCATION OF VENT AND/OR PIPE JACKS. c — AZIMUTH 1770 T MAR 2R2�1I�NORTH FIELD VERIFICATION OF ROOF STRUCTURE,AND o( o tr b SOLAR ARRAY LOCATION IS REQUIRED PRIOR TO INSTALLATION FOR ALL EXISTING STRUCTURES ',f_`1_ ED FOR CODE COMPLIANCE WHERE NEW SOLAR ARRAYS ARE TO BE INSTALLED. M G ROOF ACCESS PER CRC DOORF ACFStiS�P`�It Cid�� �., R331.4.1 WINDOW `� u Dy 'I cl1a-uVBw ARCHITECT/FIELD DRAWING INFORMATION e o� e GATE PERMITTING NHOANG 03/16/2016 CODE COMPLIANCE PROJECT DESIGNED BASED ON 2013 CEC ALL SUPPLIED EQUIPMENT IS UL LISTED 2013 CALIFORNIA BUILDING CODE *FINAL CONDUIT ROUTES TO BE DETERMINED BY CREW LEAD AT 2013 CALIFORNIA ELECTRIC CODETIME OF INSTALL, SOLAR LAYOUT *SUGGESTED CONDUIT RUNS TO BE INSTALLED UNDER EAVE AND PV_ 1 2013 CALIFORNIA FIRE DEPARTMENT CODE SHORTEST DISTANCE TO THE POINT OF INTERCONNECTION. PLAN 2013 CALIFORNIA RESIDENTIAL CODE �� �� *PAINT AND RUN CONDUIT AS REQUIRED BY JURISDICTION. 2013 ENERGY COMPLIANCE T-24 SCALE: 3/32 =1-0 *INSTALLATION SHALL COMPLY WITH REQUIREMENTS OF NEC 2011 NATIONAL ELECTRIC CODE 690.31 FOR ATTIC CONDUIT RUNS 4-511 22L aycoEfiergy PV MODULE 3222 CASTRO VALLEY BLVD CASTRO VALLEY,CA 94546 P: (510)646-7566 www.raycoenergy.com I RO N RI DG E RAIL C46 LICENSE#1001179 I RO N RI DG E FLASH FOOT PROJECT NAME: ASSEMBLY I N (E) COMP SHINGLE ROOF „ 5/16 x 4 SS LAG BOLT RESIDENCE INTO RAFTER(S) 2 1/2" MIN. 21731 SANTA BELLA PL PENETRATION W/ ROOF CUPERTINO, CA 95014 SEALANT, TYP. JURISDICTION: CUPERTINO, CITY OF STANDOFF DETAIL (14)HYUNDAI i215260RG( (14)ENPw4sE M15-60-2LL-S22- 22-IG Scale. 3 — 1-0 DRAWING NOTES: MODULE RATED AT: 260W (SOLAR MODULES HAVE A CLASS W FIRE RATING) MULTIPLY BY QTY.OF MODULES: 14 ARRAY SYSTEM SIZE: 3.64 kW tf1 SYSTEM AZIMUTH: 177 0 pO_ / B ��P` -• � ROOF PITCH: 18 4 12 MMOUNTING HEIGHT: 2-STORY CUPERTINO ORIENTATION OPTIONS ARE PRELIMINARY,AND ARE SUBJECT TO REVISION FOR OPTIMAL USE. Building Department SOLAR ARRAY LOCATIONS ARE TO BE REVIEWED AND APPROVED BY OWNER AND/OR ARCHITECT OF I RECORD TO VERIFY SYSTEM LOCATION,FOR MAR 2 4 2016 VENTILATION OBSTRUCTION AND POSSIBLE RELOCATION OF VENT AND/OR PIPE JACKS. � 1x4 SKIP SHEATHING REVIEWED FOR CODE con�Pt_iaNCE " O•�• FIELD VERIFICATION OF ROOF STRUCTURE,AND 2� n @ O�� O.C. Reviewed By: � 1� SOLAR ARRAY LOCATION IS REQUIRED PRIOR TO O INSTALLATION FOR ALL EXISTING STRUCTURES `CS WHERE NEW SOLAR ARRAYS ARE TO BE INSTALLED. 2X4�R ARCHITECT/FIELD DRAWING INFORMATION DESCRIPTIONREV DRAFTER DATE M PERMITTING NHOANG 03/16/2016 W O 1 SIDE VIEW FLUSH MOUNT ON PITCHED ROOF PV-2 APLAN LABELS ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF CALIFORNIA ELECTRICAL $ CODE WILL BE INSTALLED AS REQUIRED. , Rayco E n e r g 1/ ALTERNATE POWER SOURCE PLACARD SHALL BE METALLIC OR PLASTIC,ENGRAVED OR PHOTOVOLTAIC MODULE CALCULATIONS FOR CURRENT CARRYING CONDUCTORST MACHINE PRINTED LETTERS IN A CONTRASTING COLOR TO THE PLAQUE.THIS PLAQUE WILL BE Hyundai HiS-M260RG(BK) Max Branch AC required conductor ampacity ATTACHED BY POP RIVETS OR SCREWS OR OTHER APPROVED METHOD.IF EXPOSED TO UL1703 NEC 690.5(C)-AT THE INVERTER AND/OR GROUND FAULT SUNLIGHT,IT SHALL BE UV RESISTANT. (0.9)(15)(1.25)=15.75A INDICATOR LOCATION(AND ALL BATTERY LOCATIONS IF Power 260 W,PTC Rating 230.8 W 3222 CASTRO VALLEY BLVD APPLICABLE): EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES,EQUIPMENTS,AND AWG#10,derated ampacity CASTRO VALLEY,CA 94546 CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE WITH 250.134 OR 250.136(A) 37.7 Voc,31.1 Vmp (40)(0.71)(1.0)=28.4A P:(510)646-7566 WARNING REGARDLESS OF VOLTAGE. 6mia"M www.raycoenergy.com ELECTRICAL SHOCK HAZARD 28.4A>15.75A,therefore AC wire size is valid. IFA GROUND FAULT IS INDICATED, EACH MODULE SHALL BE GROUNDED USING THE SUPPLIED CONNECTION POINT IDENTIFIED ON C46 LICENSE#1001179 NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED THE MODULE AND THE MANUFACTURER'S INSTRUCTIONS. Enphase Energy:M215-60-2LL-S22-IG IF THE EXISTING GROUNDING ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS ONLY UL 1741,NEMA 3R,IEEE 1547 METALLIC WATER PIPING,IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A PROJECT NAME: NEC 690.14(C)(2),690.15-ON AC DISCONNECT: SUPPLEMENTAL GROUNDING ELECTRODE. Nom Voltage 240 V AC PHOTOVOLTAIC DISCONNECT PHOTOVOLTAIC EQUIPMENT SYSTEMS AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS Max Current 0.90 A SHALL ONLY BE INSTALLED BY QUALIFIED PERSONS. CONFIGURATION NEC 690.17-AT JUNCTION BOX,COMBINER BOXES AND AC ALL CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT Branch Circuits 1 DISCONNECTS: Modules per Branch 14 RESIDENCE EQUIPMENT GROUNDING CONDUCTORS SMALLER THAN 6AWG SHALL BE PROTECTED IN A WARNING RACEWAY. Number of Inverters 14 ELECTRICAL SHOCK HAZARD Record low temp 20"F DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AC SYSTEM SPECIFICATIONS AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION Max AC Output Current 12.6 A 21731 SANTA BELLA PL Operating AC Voltage 240 V CUPERTINO, CA 95014 NEC 690.35(F)-UNGROUNDED PV SYSTEMS ONLY Operating AC Power 3024 W AT EACH JUNCTION BOX,COMBINER BOX,DISCONNECT AND Operating AC Frequency 60 Hz DEVICE WHERE THE UNGROUNDED CIRCUITS'MAY BE EXPOSED DURING SERVICE: Max OCPD Rating 20 A WARNING JURISDICTION: ELECTRICAL SHOCK HAZARD.THE C U P E RTI N O, CITY O F CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED (14) HYUNDAI HiS-M260RG(BK) NEC 690.52-ON AC DISCONNECT (14)ENPHASE M215-60-2LL-S22-IG POINT OF INTERCONNECTION: PHOTOVOLTAIC SYSTEM AC SYSTEM SPECIFICATIONS DRAWING NOTES: MAX.AC OUTPUT CURRENT: BI—DIRECTIONAL OPERATING AC VOLTAGE: UTILITY METER OPERATING AC FREQUENCY: OPERATING AC POWER: 1 PHASE, 3 WIRE MODULE RATED AT: 260W MAXIMUM OCPD RATING: D 120/240 V (SOLAR MODULES HAVE A OASS-9 FIRE RATING) i NEC 705.12(D)(7)-BY BREAKER AT DISTRIBUTION EQUIPMENT: MULTIPLY BY QTY.OF MODULES: 14 u l2 ARRAY SYSTEM SIZE: 3.64 kW WARNING PV BREAKER 177 INVERTER OUTPUT CONNECTION SYSTEM AZIMUTH: DO NOT RELOCATE THIS OVERCURRENT DEVICE MURRAY MP220 150 A ROOF PITCH: 18"- 4/12 LOCATED FARTHEST MOUNTING HEIGHT: MAIN DISCONNECT 2-STORY NEC 705.10-AT SERVICE EQUIPMENT LOCATION: FROM MSD EXISTING ORIENTATION OPTIONS ARE PRELIMINARY,AND ARE PHOTOVOLTAIC ARRAY CAUTION —� •-- ® 200 A RATED SUBJECT TO REVISION FOR OPTIMAL USE. THE ELECTRICAL SYSTEM IS 30 A RATED _ , - U R IN SOLAR ARRAY LOCATIONS ARE TO BE REVIEWED ALSO PHOTOVOLTAIC ' Idir Depi i ERVICE PHOTOVOLTAIC SYSTEM BRANCH CIRCUIT 1 = 14 MODULES JUNCTION AC -�¢� y AND APPROVED BY OWNER AND/OR ARCHITECT OF BOX CPF PV METER DISCONNECT r� ,�' i RECORD TO VERIFY SYSTEM LOCATION,FOR (240V) VENTILATION OBSTRUCTION AND POSSIBLE CSFM-AC CONDUIT EVERY 10'INTERIOR/EXTERIOR �`�' '° f�- e 2016 RELOCATION OF VENT AND/OR PIPE JACKS. WARNING:PHOTOVOLTAIC POWER SOURCE • •• I �- �� FIELD VERIFICATION OF ROOF STRUCTURE,AND o D FOR jODE COMPLIANCE SOLAR ARRAY LOCATION IS REQUIRED PRIOR TO PLAQUES SHALL BE PLASTIC ENGRAVED,ATTACHED TO THE INSTALLATION FOR ALL EXISTING STRUCTURES SERVICE EQUIPMENT WITH POP-RIVETS OR ADHESIVE: G G G Reviewed WHERE NEW SOLAR ARRAYS ARE TO BE INSTALLED. EGC91 -RED BACKGROUND WITH WHITE LETTERING G -MINIMUM 3/8"LETTER HEIGHT, ARCHITECT/FIELD DRAWING INFORMATION -ALL CAPITAL LETTERS WITH ARIAL OR SIMILAR FONT REV DESCRIPTIONDRAFTER DATE TH WN-2 IN PERMITTING NHOANG n/16/2016 -WEATHER RESISTANT MATERIAL 3/4EMT NEW, IF NO " EXISTING ENPHASE AC ENGAGE CABLE OR FMC IN FREE AIR AWG #10 GROUNDING L1 = BLACK, L2 = RED, N = WHITE L1 = BLACK ELECTRODE G = GREEN L2 = RED EGC = AWG #6 BARE CU N = WHITE AWG #$ PV-3 G = GREEN PLAN BRANCH CIRCUIT #1, Isc = 12.6 A Rayco E n e rg y 3222 CASTRO VALLEY BLVD CASTRO VALLEY,CA 94546 P:(510)646-7566 www.raycoenergy.com C46 LICENSE#1001179 PROJECT NAME: I N I RESIDENCE 21731 SANTA BELLA PL CUPERTINO, CA 95014 � I JURISDICTION: CUPERTINO, CITY OF I MAIN PANEL& MAIN / I w (14) HYUNDAI HiS-M260RG(BK) SERVICE DISCONNECT *<: s, CUPERTINO (14)ENPHASE M215-60-2LL-S22-IG (IN GARAGE) iC& Building Department DRAWING NOTES: 2016 / Y MODULE RATED AT: 260W ' \X m T—i REVIEWED FOR CODE COMPLIANCE «MODULES HAVE A CLASS"A"FIRE RAZING) W I Reviewed By: Tk�'P�Voj MULTIPLY BY QTY.OF MODULES: 14 4U 1 0 ± ARRAY SYSTEM SIZE: .64 kW .1 Lo 8 � I SYSTEM AZIMUTH: 1 77 1 'f I 18°= 4/12 ROOF PITCH: DRIVEWAY I MOUNTING HEIGHT: 2-STORY ORIENTATION OPTIONS ARE PRELIMINARY,AND ARE Lu I SUBJECT TO REVISION FOR OPTIMAL USE. Q I SOLAR ARRAY LOCATIONS ARE TO BE REVIEWED N I AND APPROVED BY OWNER AND/OR ARCHITECT OF z RECORD TO VERIFY SYSTEM LOCATION,FOR VENTILATION OBSTRUCTION AND POSSIBLE RELOCATION OF VENT AND/OR PIPE JACKS. `� SOLAR PV ON ROOF FIELD VERIFICATION OF ROOF STRUCTURE,AND TE M \ SOLAR ARRAY LOCATION IS REQUIRED PRIOR TO "V I INSTALLATION FOR ALL EXISTING STRUCTURES ` \ I WHERE NEW SOLAR ARRAYS ARE TO BE INSTALLED. UTILITY METER 89' ` ARCHITECT/FIELD DRAWING INFORMATION AC DISCONNECT i DRAFTER" '' \ PERMITTING NHOANG 03/16/2016 SITE PLAN PV-4 1 SCALE: 1"=20'-0" PLAN AAL IRON RIDGE Roof Mount System RaycoEnergy lllli, yu, n a 0-1 Enphase4,Mlcrainverters 41 On a Ir h,fi�a od"ut 'i 1�a 3222 CASTRO VALLEY BLVD people,HyundaiHeavy indusulowas founded In 1972 and iso Fortune 500 company The cc-pniemploys morethan4"M P'."dho.label leading 71 business divisions with sales of 60,2 Billion USD In 2012.AS one of our core businesses of the conip-8y,flyundal Heavy Industries is Enphase,,M215 Commin to develop and Investheully in the field of renewable GASTRO VALLEY,CA 94546 ed Hyundai capadsir�ll 1111,largest and the longest standing PV mil and module manufacturer In South Korea.We have 600 MW of module production P: (510)646-7566 dp rovide high-qui,lity solar Pv products to more than 3,000 customers worldwide.We smile to achieve one of the most efficient FV module, by establishing an R&D laboratory and Investing more than 20 Million USD on Innovativouihrolgie, www.raycoenergy.com Multi-Crystalline Type C46 LICENSE#1001179 HiS-M250RG I HiS.M255RG I HiS-M26ORG RG-Series M... -crystalline Type H&526ORG I HIS-5265PG I HIS-527ORG I PROJECT NAME: Mechanical Characteristics CUPERTINO E77, 998 (3929')(IN)X- 1.640 mm(6437)(L)x 35 mm(1.38')(H) [e]enphase Building Mepartment a- ,..I comtect-, App17�2 kg(37.9 lost E N R G Y ssiT - 60 cells lnrries(6xl0 maula)Hyuidal cell,Made In Korea). 4 m'(I 2AWG) of.with polarized- help IEC certified ILL listed),Length 1.0 M(39,49 2016 1i IP68,weatherproof.IEC certified ILL listed) U-11ME-j 3 byp._dides to prevent power decrease by partial shade Front:4igl­urissi-I-irc.ism-ed glass,m min(0.11 lincapsulant:EVA Back Sheat:01cathemmof film -ESIDENCE Oearanodmed aluminum alloy We 6063 Built for solar's toughest roofs. REVIEWED FOR CCIDE COMPUR High Quality lronRidge builds the strongest roof mounting system in solar.Every component has be tested to the li The Enphase'Microinverter System improves energy harvest,increases reliability,and dramatically and proven in extreme environments. eviewe y: •IEC,61215(Ed.2)and IEC 61730byVDE I T�B A4U�& UL isted(UL 1703),Clos;C Fire Rating •Output power tolerance+3M av simplifies design,installation,and management of solar power systems. Our rigorous approach has led to unique structural features,such as curved rails and reinforced flashings,and 21731 SANTA BELLA PL •ISO 9DOI:2000 and ISO 14001:2OD4 Cenified is also why our products are fully certified,code compliant and backed by a 20-year warranty. .Ad The Enphase System includes the microinverter,the Envoy'Communications Gateway,"and vancedMeclianicalTess(5,4001'a)Passed(IEQ Mechanical Lwd T�(40 fibs/fitrI Passed ILL) Enlighten,'Enphase's monitoring and analysis software. CUPERTINO, CA 95014 .Ammonia Corrosion flesistancaTestirassed •IEC 61701(5ah Mist ComosIon Tea)passed ..®�®i�i� • Strength Tested PE Certified Fast and Inexpensive Mounting Delivered ready for connection PRODUCTIVE SMART All components evaluated for superior Pre-stamped engineering letters i®I® structural performance. available in most states. -:ECRIQoertified notweaherpr-f-rinect.is, Maximum energy production Quick and simple design,installation, adl.des' -itegnsted bypass Resilient to dust,debris and shading and management Performance monitoring 241T monitoring and analysis K- JURISDICTION: Limited Warranty Class A Fire Rating Design Software •10 years ficpnoductclefect •0yea's fo�90%ofwarramod min.power Certified to maintain the fire RELIABLE SAFE resistance Online tool generates a complete bill of 25 years for 80%ofwastanted min,power System availability greater than 99.8% Low-voltage DC rating of the existing roof. materials in minutes. CUPERTI NO, CITY OF No single point of system failure Reduced fire risk Integrated Grounding 20 Year Warranty (14)HYUNDAI HIS-MMORG(BK) UL 2703 system eliminates separate Twice the protection offered by -I iRar --- HYUNDAI enphase- module grounding components. competitors. (14)ENPHASE M215-60-2LL-S22-IG C E0k HEAVY INDUSTRIES 00-113D. module DRAWING NOTES: Electrical Characteristics XR Rails I Multi-crystalline Type Enphase,r M215 Microinverter DATA XR10 Rail XR100 Rail XR100D Rail Internal Splices 0 MODULE RATED AT: 260W (SOLAR MODULES HAVE A CLASS-A'FIRE RATING) INPUT DATA(DC) M215-60-2LL-S22/523 and M215-60-2LL-S22-NA/S23-NA(Ontario) 10 260, I v _X9 31a Recommended input pavver(STC) MULTIPLY BY QTY.OF MODULES: 14 aA I A 8.1 11? Maximum DC voltage 45 V Peak power tracking voltage -To FkvPim9eN-cL V 37A 37.6 - A 87 j ARRAY SYSTEM SIZE: 3.64 kW 81 t _ - 22•-.36 V 'UC) Operating range 16-36 V A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices Aakaalco�,qy 22V/45V for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. 1770 Max.DC short circuit current ISA 6'spanning capability B'spanning capability 12'spanning capability Self-tapping screws SYSTEM AZIMUTH: Wx As -T­Wauvc.cffici-.fvoC 43 -2 Mmc.input current 10.5 A Moderate load capability Heavy load capability Extreme load capability Varying versions for rails 18"= 4112 aw Te.pa.iumcffid 01�48 o Clear anodized finish •Clear&black anod.finish •Clear anodized finish •Grounding Straps offered ROOF PITCH: OUTPUT DATA(AC) @208 VAC 4'240 VAC Mono-crystalline Type Rated(continuous),Oulput power .215W 215W Attachments MOUNTING HEIGHT: 2-STORY Nominal output current 1.0 A(Arms at nominal duration) 0.9 A(Arms at nominal duration) FlashFoot Slotted L-Feet Standoffs Tilt Legs ORIENTATION OPTIONS ARE PRELIMINARY,AND ARE 7- -Nominal voltage/range 208/183-229V 240/211-264 V Na„ lo,ms (P pp w 265 vp Extended voltage/range 179-232 V 206-2,39 V SUBJECT TO REVISION FOR OPTIMAL USE. vo!Ag­IP­(v,pp) v 311 313 31A Nominal f quency/range 60,0/59.3-0.5 HZ 60.0159.3-60.5 Hz BS'A I i - - _i, .-- 8.6 am o.unw�nagww v -9 Extended frequency range 57-60.5 Hz 57-60.5 Hz SOLAR ARRAY LOCATIONS ARE TO BE REVIEWED 51-6-i"momi.1 A 1 9.2 7j 7 AND APPROVED BY OWNER AND/OR ARCHITECT OF Power factor >0.95 >0.95 P Our �ivc; - , &4 pc! sal­J. Maximum units per 20 A branch circuit 25(three phase) 17(single phase) RECORD TO VERIFY SYSTEM LOCATION,FOR coil tyw. 3 : i - - Anchor,flash,and mount Drop-in design for rapid rail Raise flush or tilted Tilt assembly to desired 15.9 Maximum output fault current 1.05 Arms.over 3 cycles,1.04 Arms over 5 cycles VENTILATION OBSTRUCTION AND POSSIBLE &2 I&S with all-in-one attachments. attachment. systems to various heights. angle,up to 45 degrees. 7-Ter;-_­_,.fP.pP 'a's o,45 RELOCATION OF VENT AND/OR PIPE JACKS. EFFICIENCY T___ w..tv. I Ships with all hardware High-firiction serrated face •Works with vent flashing •Attaches directly to rat enc 4 CEC weighted efficiency 9610% TITTL 11 1 -4U -2 IEC&IRC compliant Heavy-duty profile shape Ships pre-assembled Ships with all hardware Peak Inverter efficiency 9B.3% Certified with XR Rails Clear&black anod.finish Lengths from 3"to 9' Fixed and adjustable FIELD VERIFICATION OF ROOF STRUCTURE,AND I Module Diagram I Static MF-Pf-efficiency(weighted,reference EN5o536) 99.6o Clamps&G TION IS REQUIRED PRIOR TO I-V curves I - - Dynamic MPPT efficiency(fast Irradiation changes,reference EN50530) 99.3% rounding SOLAR ARRAY LOCA ...... INSTALLATION FOR ALL EXISTING STRUCTURES Night time power consumption 46 mW End Clamps Grounding Mid Clamps T-Bolt Grounding Lugs Accessories WHERE NEW SOLAR ARRAYS ARE TO BE INSTALLED. MECHANICAL DATA Ambient temperature range -40-C to 651C Operating temperature range lintemai) -401C to+85C . . . 5V -7, F�? ? ARCHITECT/FIELD DRAWING INFORMATION _!7-�cm���A��mx25cm(68"x6.45"x,1.0 witho mountingbracket Dimensions(WxH kZ ­'_ -'_1 - ."), --ul Weight LL we 1 1.6 �3.5 lbs) PERMITTING NHOANG 03/16/2016 Cooling Natural cc!n,!o!I9n..No!a Slide in clamps and secure Attach and ground modules Ground system using the Provide a finished and Enclosure environmental rating Outdoor-NEMA 6 modules at ends of rails. in the middle of the rail. rail's top slot. organized look for rails. FEATURES Mill finish&black anod. Parallel banding T-bolt Easy top-slot mounting Snap-in Wire Clips 2 Compatibility Pairs wit most 60-cell PV modules Sizes from 1.2"to 2.3" Reusable up to 10 times Eliminates pre-drilling Perfected End Caps Optional Under Clamps Mill&black stainless Swivels in any direction UV-protected polymer I installation safety Guide Communication- Power fine •Only qualiifid personnel should Install or perform maintenance. -o­C Monitoring Free lifetime monitoring via Enlighten software Free Resources •11-warefd.rigero.,high DC vc1cage. DC1i00CVIiEQ Compliance UL1741AEEE1547.FCC Part 15 class B .D no:damage or scratch the rearsurface ofth module M _,DC600v(UP Co e mcd -Do handle or install modulo when they a ISA CiAN/CSA-C22.2 NO,.6-M91,0.4-94,and 1071-01 Assistant NASCEP Certified Training Go from rough layout to fully q( Earn free continuing education credits, -5 ®-engineered system.For free. while leaming more about our systems. PV Go to IrionFifidge.com/rin A�T Go to hronRidge.com/training To learn more about Enphase Microinverter technology, ....... PLAN [e]enphase, �F' HYUNDAI visit enphase.com E N E R G Y HEAVY INDUSTRIES CO-LTD. ©2013 Enphase Envqry ail lignis ma-,cl.A,tmos­, c,tl.­05 a,,Ha d­,a, _­nv, y, SMOKE / CARBON MONOXIDE ALARMS OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION CUPERTINO 10300 TORRE AVENUE•CUPERTINO,CA 95014-3255 (408)777-3228•FAX(408)777-3333•building(�i_)cupertino.org �7 (Permit o. J b� ^ �� ress f aZ � ,�1LCi I Q\, F ";Z, lW of_Marms S-mokR (-Carbon M oxides PERMIT CANNOT BE FINALED AND COMPLETEDUNTIL THIS CERTIFICATE 4, HAS BEEN SIGNED AND RETURNED TO THE BUILDING DIVISION PURPOSE This affidavit is a self-certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R314,2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single-family and multi-family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations,or repairs to existing dwelling units exceeds $1000.00, CRC Section R314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations: AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of the X X bedroom(s) On every level of a dwelling unit including basements X X Within each sleeping room X Carbon Monoxide alarms are not required in dwellings which do not contain fuel-burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. Power Supply:In dwelling units with no commercial power supply,alarm(s)may be solely battery operated. In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic,basement or crawl space.Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2.An electrical permit is required for alarms which must be connected to the building wiring. As owner of the above-referenced property,I hereby certify that the alarm(s)referenced above has/have been , installed in accordance with the manufacturer's instructions and in compliance with the California Building and California Residential Codes.The alarms have been tested and are operational, as of the date signed below. I have read and agree to comply with the terms and conditions of this statement /Owner or w�Agent s R-6-5 tl(R�a GVl tL/1 (S natur ........ ..........(Da W. ��a•1.1. .. (Contracto�m 71 (Si n—a ure).................................................................(Gc.#)......................................(Dawe ................... Smoke and CO form.doc revised 03118/14 WATER-CONSERVINGPLUMBING FIXTURES OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION CUPERTINO 10300 TORR'E AVENUE•CUPERTINO,CA 95014-3255 ,—(108)777-3 8•FAX(408)777-3333 building(a_)cupertino.ora t^- (Owner (A-h Permit Nof 2-616— 16 1 ? Address 3 f NZ�G✓ a. l7� , 'C�' t— 1 SIP Z Cly. Is your real property a registered historical site? 11 Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. M No Go to Question 2. Does your real property have a licensed plumber certifying that,due to the age or configuration of the property or its plumbing,installation of water-conserving plumbing fixtures is not technically feasible? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. ❑ The licensed plumber's certification has been provided to the Building Division. Skip the rest of the form and sign bottom of form. 10 No Go to Question 3. (� Is water service permanently disconnected for your building? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the.rest of the form and sign bottom of form. Ur No Go to Question 4. Is your real property built and available for use or occupancy on or before January 1, 1994? ❑ No My real property is built and available for use or occupancy after January 1, 1994. Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. [ Yes My real property is built and available for use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101.8 apply. Check one of the three following statements and sign bottom of form.. C:K) Pl ase check ONE of the following: My property is a single-family residential real property. See Civil Code Section 1101.4. On and after January 1,2014,building alterations or improvements shall require all non-compliant plumbing fixtures to be replaced with water-conserving plumbing fixtures throughout the building.On or before January 1,2017;all non-- compliant plumbing fixtures shall be replaced with water-conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements). El My property is a multifamily residential real property. See Civil Code Section 1101.5. On and after January 1,2014,specified building alterations or improvements shall require non-compliant plumbing fixtures to be replaced with water-conserving plumbing fixtures. On or before January 1,2019,all non-compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building(regardless of whether property undergoes alterations or improvements). ❑ My property is a commercial real property. See Civil Code Section 1101.5., On and after January 1,2014,specified building alterations or improvements shall require non-compliant plumbing fixtures to be replaced with water-conserving plumbing fixtures. On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building(regardless of whether property undergoes alterations or improvements). 1,as the owner or owner's agent of this property,certify under penalty of perjury that non-compliant plumbing fixtures will be replaced prior to date specified above with water-conserving plumbing fixtures in accordance with Civil Code Sections 1101.1 through 1101.8,the current California Plumbing Code and California Green Building Standards Code,and manufacturer's installation requirements,and that the water-conserving plumbing fixtures comply with the requirements as indicated in the table on the following page. C w�Ow eer Ague's Si na ure: . a e Upon completing and signing this Certificate,please return it to the Building Division in order to final your building permit. SB4072015.doc revised 08126115