Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
B-2016-1658
CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO: B-2016-1658 10190 HILLCREST RD CUPERTINO, CA 95014-1023 (326 16 064) SUNRUN INSTALLATION SERVICES INC SAN LUIS OBISPO, CA 93401 OWNER'S NAME: MERRICK ROBERT G TRUSTEE & ET AL DATE ISSUED: 03/30/2016 OWNER'S PHONE: 408-446-1168 PHONE NO: (888) 657-6527 LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO: License Class C46 Lic. #750184 Contractor SUNRUN INSTALLATION SERVICES INC Date 06/30/2016 X BLDG —ELECT —PLUMB MECH X RESIDENTIAL COMMERCIAL I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. JOB DESCRIPTION: I hereby affirm under penalty of perjury one of the following two declarations: 1. I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. A11162. I have and will maintain Worker's Compensation Insurance, as provided for by �ection 3700 of the Labor Code, for the perfonnance of the work for which this (� permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Osignature Date 3/30/16 OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: 1. I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or -offered for sale (Sec.7044, Business & Professions Code) 2. I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.7044, Business & Professions Code). I hereby affirm under penalty of perjury one of the following three declarations: 1. I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. I APPLICANT CERTIFICATION 14 I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. INSTALLATION OF ROOF MOUNTED SOLAR (19 MODULES)(4.6kW) Sq. Ft Floor Area: I Valuation: $10000.00 APN Number: Occupancy Type: 326 16 064 PERMIT EXPIRES IF WORK IS NOT STARTED WITHIN 180 DAYS OF PERMIT ISSUANCE OR 180 DAYS FROM LAST CALLED INSPECTION. Issued by: SHATCH ::L /7 Date: 3/30/166 RE -ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. Signature of Applicant: Date: 3/30/16 ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER HAZARDOUS MATERIALS DISCLOSURE I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Sections 25505, 25533, and 25534. Owner or authorized agent: Date: 3/30/16 CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name Lender's Address ARCHITECT'S DECLARATION I understand my plans shall be used as public records. Signature Date 3/30/16 Licensed CUPERTINO TKA ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT ` BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building cuDertino.org ;'�-94:mb -�b� PROJECT ADDRESS 1 Q r 010 l l )Lj_& #_057- F AYNNN OWIviR NA) 4E J(- y'�fr ItiGK I PHONE Q/O'ej qq E-MAIL STREET ADDRESS J I /�D CITY, STATE, ZIP I FAX CONTACT NAME PHONE 93 ! 35?� E-I,�rAIL �UJr✓�L q,v, i7arr n ccn� STREET ADDRESS y3 ce, 7-*jkjlC RID, S7 CITY, STATE, ZIP ' S -N '00,re— e: 1- 51 I FAX i❑ ow,, -R ❑ ONT=R AGE? ,1 ❑ CONTRACTOR ACONT P4CTOR AGENT ❑ ARCI-=-CT ❑ ENGINEER ❑ DE\rELOPER ❑ T-ENANT CONTRACTOR NAIVE LICEN'LT4BER� ,r LICE �E BUS. LIC COI✓.PANY NAIVE S U7UAu?/, wc— I E-MAIL 691 &/ 7r-14F�jqe iZ 6,10, 9WgtN I FAX r LCi-Yd/) STREE ADDRESS��Da I CITY, STATE, ZIP PHONE ARMTECT/ENGINEER NAIVE I LICENSE Na'j'BER BUS. LIC R COMPANY NAME I E-MAIL FAX STREET ADDRESS I CITY, STATE, ZIP PHONE USE OF SFD or Duplex ❑ Multi -Family PROJECT IN WILDLAND PROJECT IN STRUCTURE: ❑ CommeIcia.l URBAN INTERFACE AREA ❑ Yes ❑ No FLOOD ZONE ❑ Yes ❑ NO SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER DATING ❑ OTFIEER: FOR SOLAR PAA-ELS. NUMBER OF PANELS/UIvITS: a� KILOWA O',431\1ERCIAL ONLY): TOTAL VALUATION: DESCRIPTION OF WORK pevj=, SbcA-p ^ �RECFI� tD BX --1- �'s By my signature below, I certify to each of the following: I am the properjr o%�'ner or authorized agent to act on the property oN ner's behalf. I have read this application and the information I have provided is correct. I have read the Description of Work and verij, it is accurate. I agree to comply With all applicable local ordinances and state laws relating to building construction. I authorize representatives of Cupertino to enter the above- identifi d property for inspection purposes. S ignature of Applicant/Agent: Date: (D SUPPLE1\6ENTAL rNTFORMATION REQUIRED ' 4 OERTBFyCOUI�TERS,. r' .._.-..,-.caa...�.- _.�_.. .. ..-i. G f S S"y C. ¢y—� t S 20 I AlA70Rfi PM4pp_2011.doc revised 03116111 C.50®2 � P Canadian Solar's new Quartech modules have significantly raised the standard of module efficiency in the solar industry. They introduced innovative four busbar cell technology, which demonstrates higher power output and higher system reliability. Worldwide, our customers have embraced this next generation of modules for their excellent performance, superior reliability and enhanced value. NEW TECHNOLOGY Reduces cell series resistance Reduces stress between cell interconnectors Improves module conversion efficiency Improves product reliability KEY FEATURES I �..anadianSolar :kframe uct can be ded upon y ..2St. 2 5 insurance -backed warranty years non -cancelable, immediate warranty insurance w` linear power output warranty °ww 10 ` product warranty on materials 3 and workmanship MANAGEMENT SYSTEM CERTIFICATES Outstanding performance at low irradiance ISO 9001:2008 / Quality management system Maximum energy yield at low NOCT ISO/TS 16949:2009 / The automotive industry quality management system Improved energy production through ISO 14001:2004 / Standards for environmental management system reduced cell series resistance OHSAS 18001:2007 / International standards for occupational health & safety -• .•. ,-.. ..-';:'as;.+,iiit',, PRODUCT CERTIFICATES Long-term system reliability with IP67 IEC 61215/IEC 61730: VDE/MCS/CE /JET/SII/CEC AU/INMETRO/CQC junction box UL 1703 / IEC 61215 performance: CEC listed (US) / FSEC (US Florida) Enhanced system reliability in extreme UL 1703: CSA / IEC 61701 ED2: VDE / IEC 62716: VDE / IEC 60068-2-68: SGS temperature environment with special PV CYCLE (EU) / UNI 9177 Reaction to Fire: Class 1 cell level stress release technology Positive power tolerance up to 5 W Stronger 40 mm robust frame to hold snow load up to 5400 Pa and wind load up to 2400 Pa Anti -glare project evaluation Salt mist, ammonia and blowing sand resistance apply to seaside, farm and desert environments BBW PV CYCLc �+ CERf; CANADIAN SOLAR INC. is committed to providing high quality solar products, solar system solutions and services to customers around the world. As a leading manufacturer of solar modules and PV project developer with about 10 GW of premium quality modules deployed around the world since 2001, Canadian Solar Inc. (NAS- DAQ: CSIQ) is one of the most bankable solar companies worldwide. 51 MODULE J ENGINEERING DRAWING (mm) 35 11 " I Aoundng Hoi(� —7 1 R ELECTRICAL DATA I STC* 7175E Nominal Max. Power (Pmax) 260 W 265 W Opt. Operating Voltage (Vmp) ........ ... 30.4V 30.6 V Opt. ...Operating . Current 1..... .... ........ 5_61.A____ 8-.6 6.-A -,(.I.m-p..)..-,--.8,. Open Circuit Voltage (Voc) I . ... ..... ... _._... . ............. . ..... ........ 37.5 V 37.7 V - ----- ---- Short Circuit Current (Isc) .... ...... I .. .. . ...................... 9.12 A 9.23 A Module Efficiency ..... . .... 16.16% 16.47% Operating Temperature ... . ...... -400C -+850C .................. ..... .. Max. System Voltage .._..1__....__ ... ...... . . ....... _... � . . .... .. ... . ........ 1000 V (IEC) or 1000 V (UL) Module Fire Performance TYPE 1 (UL 1703) or CLASS C (IEC61730) . ......... ------- Max. Series Fuse Rating ... . ... ... .... ..... . ... . 15A Application Classification ... . - � ....... ................ . Class A Power Tolerance .... ....... . .... ... .... . . . .. . ... ..... 0-+5W Under Standard Test Conditions (STC) of irradiance of 1000 W/ml, spectrum AM 1.5 and cell temperature of 25°C. ELECTRICAL DATA NOCT* S '!65P Nominal Max. Power (Pmax) 189 W 192 W Opt. .-Operating -.Voltage 27.9 V ..(.Vm.p.)27...7-.V Opt. Operating Current (Imp) 6.80 V 6.88 A --------- --- Open Circuit Voltage (Voc) 'Current 34.5 V 34.7 V Short Circuit (Is;c) 7.3-9,A'' Under Nominal Operating Cell Temperature (NOCT), irradiance of 800 W/M2, spectrum AM 1.5, ambient temperature 20°C, wind speed 1 m/s. PERFORMANCE AT LOW IRRADIANCE Industry leading performance at low irradiation, average +96.5% relative efficiency from an irradiance of 1000 W/M2 to 200 W/M2 (AM 1.5, 250C). The specification and key features described in this datasheet may deviate slightly and are not guaranteed. Due to on -going innovation, research and product enhancement, Canadian Solar Inc. reserves the right to make any adjustment to the information described herein at any time without notice. Please always obtain the most recent version of the datasheet which shall be duly incorporated into the binding contract made by the parties governing all transactions related to the purchase and sale of the products described herein. Caution: For professional use only. The installation and handling of PV modules requires professional skills and should only be performed by qualified professionals. Please read the safety and installation instructions before using the modules. CS6P-260P I I-V CURVES A A 7 6 5 4 3 2 1 v 0 5 10 15 20 25 30 35 40 v 5 10 15 20 25 30 35 40 F1 l000w/w s*c n 800 w/w 25,c 22 600 W/W 45°C 400 WW 65°C MODULE / MECHANICAL DATA spedff ica tio n, DaT�� C TY ell pe . .. ............ Poly -crystalline, 6 inch Cell Arrangement - -- - --------------- - ...... . . ........ .. . ...... ...... ............. 60 (6x 10) Dimensions ... . .... . ............... ......... . . ....... ..... ............... .. . .. 1638x982x40mm(64.5x38.7x1.57in) Weight . ........... ....... - ...... 18 kg (39.7 lbs) Front Cover . ... ... 3.2 mm tempered glass ..... .... . ..... . _ ............ Frame Material ----- ------ Anodized aluminium alloy — J-Box ........... ............ . ... .... .. .... IP67, 3 diodes Cable 4 MM2 (IEC) or 4 MM2 & 12AWG 1000 V (UL), 1000 mm (39.4 in) . Connectors Friends PV 2a IEC , ......... .. Friends PV2b (IEC / UQ Standard . ........... . ..... . ........ ... 26 pieces, 515 kg (1135.4 lbs) Packaging (quantity & weight per pallet) Module Pieces per Container ................ ............ . .. ...... 728 pieces (40' HQ) . . ......... ............ ........ ..... TEMPERATURE CHARACTERISTICS Temperature --Coe.ffic..ie.n,t--....m*ax)' Temperature Coefficient (Voc) ...... ......... -0.31 % IC Temperature Coefficient Is c) ---- - ------- -----------0.053% OC Nominal Operating Cell Temperature ___.._......_1 ........ .. ...... 4 - 5 . ±20 ....... -- PARTNER SECTION ................... ........ .......... ............. ........ ..... ...... ........... ............ .............. ....... ....... ....................... Scan this QR-code to discover solar projects built with this module 111 ..................... ..." ... I ....... ........... : N, CSA Croup of,4" A��. r , "u" 'fi Certiifleateo 2284121 Project. 70048197 Issued to: Canadian Solar Inc 545 Speedvale Ave West Guelph, Ontario N1K ]IE6 CANA)fDA Attention: Jean -Nicolas ,>{auubert M2ster Contract: 249143 Date Issued: 2015-10-05 Thep °duds lasted below are eligible t® bear the CSA Mark shown with adjacent indicators 'C' and 'US'for Canada and CIS or with adjacent indicatory 'US'for ITS only or without either indicator for Canada only. Issued by. A nh' (A ndy) C us Anh (Andy) Nguyen PRODUCTS CLASS - C531110 - POWER SUPPLIES -Photovoltaic Modules and Panels CLASS - C531190 - POWER SUPPLIES -Photovoltaic Modules and Panels - Certified to US Standards Photovoltaic Modules with maximum system voltage of 600 V do or 1000 V do and Type 1 module fire performance, Model Series CS6X-XXXP, cCS6X-XXXPX, where'XXX' is the power output from 250 W to 330 W with the following electrical ratings typical at 305 W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 44.8 V Short Circuit Current (Ise): 8.97 A Operating Voltage (Vpmax): 36.3 V Current at Operating Voltage (Ipmax): 8.41 A Photovoltaic Modules with maximum system voltage of 600 V do or 1000 V do and Type 1 module fire performance, Model Series CS6X-XXXM, where 'XXX' is the power output from 260 W to 350 W with the following electrical ratings typical at 350 W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 46.6 V Short Circuit Current (Ise): 9.67 A Operating Voltage (Vpmax): 38.3 V Current at Operating Voltage (Ipmax): 9.14 A CSA Group Certifneate: 2284121 Project: 70048197 Master Contract: 249143 Date Issued: 2015-10-05 Photovoltaic Modules with maximum system voltage of 600 V do or 1000 V do and Type 1 module fire performance, Model Series CS6P-XXXP, CS6P-XXXP-S, CS6P-XXXPX where'XXX' is the power output from 200 W to 275 W with the following electrical ratings typical at 260 W for CS6P-XXXP/ CS6P-XXXP-S, and CS6P-XXXPX series respectively @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 37.5 V Short Circuit Current (Ise): 9.12 A Operating Voltage (Vpmax): 30.4 V Current at Operating Voltage (Ipmax): 8.56 A Photovoltaic Modules with maximum system voltage of 600 V do or 1000 V do and Type 1 module fire performance, Model Series CS6P-XXXM and CS6P-XXXMX where 'XXX' is the power output from 200 W to 290 W with the following electrical ratings typical at 290 W for CS6P-XXXM and CS6P-XXXMX series respectively @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 38.7 V Short Circuit Current (Ise): 9.59 A Operating Voltage (Vpmax): 31.9 V Current at Operating Voltage (Ipmax): 9.09 A Photovoltaic Modules with maximum system voltage of 600 V do and Type 1 module fire performance, Model Series CSSA-XXXM, , where 'XXX' is the power output from 170 W to 210 W with the following electrical ratings typical at 210 W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 45.6 V Short Circuit Current (Ise): 5.90 A Operating Voltage (Vpmax): 38.1 V Current at Operating Voltage (Ipmax): 5.51 A Photovoltaic Modules with maximum system voltage of 600 V do and Type 1 module fire performance, Model Series CS6A-XXXP, where 'XXX' is the power output from 160 W to 210 W with the following electrical ratings typical at 210 W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 30.0 V Short Circuit Current (Ise): 9.19 A Operating Voltage (Vpmax): 24.4 V Current at Operating Voltage (Ipmax): 8.63 A Photovoltaic Modules with maximum system voltage of 600 V do and Type I module fire performance, Model Series CS6F-XXXM, where 'XXX' is the power output from 30W to 40W with the following electrical ratings typical at 40W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 22.8 V Short Circuit Current (Ise): 2.28 A Operating Voltage (Vpmax): 18.6 V Current at Operating Voltage (Ipmax): 2.15 A 13 N, CSA 'vk ' Group Certificate: 2284121 Project: 70048197 Master Contraet: 249143 Date Issued- 2015-10-05 Photovoltaic Modules with maximum system voltage of 600 V do and Type 1 module fire performance, Model Series CS6F-XXXP, where'XXX' is the power output from 30W to 40W with the following electrical ratings typical at 40W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 22.6 V Short Circuit Current (Ise): 2.32 A Operating Voltage (Vpmax): 18.4 V Current at Operating Voltage (Ipmax): 2.17 A Photovoltaic Modules with maximum system voltage of 600 V do and Type 1 module fire performance, Model Series CS6H-XXXM, where 'XXX' is the power output from 20W to 26W with the following electrical ratings typical at 26W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 22.7 V Short Circuit Current (Ise): 1.5 A Operating Voltage (Vpmax): 18.4 V Current at Operating Voltage (Ipmax): 1.41 A Photovoltaic Modules with maximum system voltage of 600 V do and Type 1 module fire performance, Model Series CS6H-XXXP, where'XXX' is the power output from 20 W to 26 W with the following electrical ratings typical at 26 W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 22.5 V Short Circuit Current (Ise): 1.52 A Operating Voltage (Vpmax): 18.2 V Current at Operating Voltage (Ipmax): 1.43A Photovoltaic Modules with maximum system voltage of 600 V do and Type 1 module fire performance, Model Series CS6E-XXXM, where 'XXX'is the power output from 45 W to 60 W with the following electrical ratings typical at 60 W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 22.8 V Short Circuit Current (Ise): 3.42 A Operating Voltage (Vpmax): 18.6 V Current at Operating Voltage (Ipmax): 3.23 A Photovoltaic Modules with maximum system voltage of 600 V do and Type 1 module fire performance, Model Series CS6E-XXXP, where'XXX' is the power output from 45 W to 60 W with the following electrical ratings typical at 60 W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 22.6 V Short Circuit Current (Ise): 3.47 A Operating Voltage (Vpmax): 18.4 V Current at Operating Voltage (Ipmax): 3.26 A CSA Group Certificate: 2284121 Project: 70048197 Master Contract: 249143 )[Date Issued: 2015-10-05 Photovoltaic Modules with maximum system voltage of 600 V do and Type 1 module fire performance, Model Series CS6D-XXXM, where 'XXX' is the power output from 60 W to 75 W with the following electrical ratings typical at 75 W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 22.5 V Short Circuit Current (Ise): 4.37 A Operating Voltage (Vpmax): 18.3 V Current at Operating Voltage (Ipmax): 4.11 A Photovoltaic Modules with maximum system voltage of 600 V do and Type 1 module fire performance, Model Series CS6D-XXXP, where'XXX' is the power output from 60 W to 75 W with the following electrical ratings typical at 75 W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 22.3 V Short Circuit Current (Ise): 4.43 A Operating Voltage (Vpmax): 18.1 V Current at Operating Voltage (Ipmax): 4.15 A Photovoltaic Modules with maximum system voltage of 600 V do and Type 1 module fire performance, Model Series CS6C-XXXM, where 'XXX' is the power output from 120 W to 175 W with the following electrical ratings typical at 145 W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 22.4 V Short Circuit Current (Ise): 8.52 A Operating Voltage (Vpmax): 18.1 V Current at Operating Voltage (Ipmax): 8.01 A Photovoltaic Modules with maximum system voltage of 600 V do and Type 1 module fire performance, Model Series CS6C-XXXP, where 'XXX' is the power output from 120 W to 165 W with the following electrical ratings typical at 150 W @.Standard Test Condition (STC): Open Circuit Voltage (Voc): 22.3 V Short Circuit Current (Ise): 8.87 A Operating Voltage (Vpmax): 18.1 V Current at Operating Voltage (Ipmax): 8.30 A Photovoltaic Modules with maximum system voltage of 600 V do or 1000 V do and Type I module fire performance, Model Series CS6K-XXXP, where `XXX' is the power output from 220 W to 275 W with the following electrical ratings typical at 275 W for CS6K-XXXP series @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 38.0 V Short Circuit Current (Ise): 9.45 A Operating Voltage (Vpmax): 31.0 V Current at Operating Voltage (Ipmax): 8.88 A Rev. 20 a CSA Group Certaicate: 2284121 Project. 70048197 Master Contract: 249143 Date Issued: 2015-10-05 Photovoltaic Modules with maximum system voltage of 600 V do and Type 1 module fire performance, Model Series CS6A-XXXM, where 'XXX' is the power output from 160 W to 230 W with the following electrical ratings typical at 205 W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 30.6 V Short Circuit Current (Ise): 9.31 A Operating Voltage (Vpmax): 24.8 V Current at Operating Voltage (Ipmax): 8.87 A Photovoltaic Modules with maximum system voltage of 600 V do or 1000 V do and Type 1 module fire performance, Model Series CS6K-XXXM, where'XXX' is the power output from 240 W to 290 W with the following electrical ratings typical at 290 W for CS6K-XXXM series @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 38.7 V Short Circuit Current (Ise): 9.59 A Operating Voltage (Vpmax): 31.9 V Current at Operating Voltage (Ipmax): 9.09 A Photovoltaic Modules with maximum system voltage of 600 V do and Type 1 module fire performance, Model Series CS6P-XXXP-SD, and CS6K-XXXP-SD where'XXX' is the power output from 240 W to 275 W with the following electrical ratings typical at 250 W @ Standard Test Condition (STC): Output Voltage Range (Vout): 5 — 60 V Maximum Output Current (Imax): 15 A Photovoltaic Modules with maximum system voltage of 600V or 1000 V do and Type 1 module fire performance, Model Series CS6P-XXXP-TD, where 'XXX' is the power output from 240 W to 275 W with the following electrical ratings typical at 250 W @ Standard Test Condition (STC): Output Voltage Range (Vout): 16 — 32 V (Voc*) Maximum Output Current (Imax): 9.5 A *For modules with Smart Curve function the Voc is adjustable and is programmed only at the factory based on the PV module voltage. Notes: Rated electrical characteristics are within +/-10% of measured values at Standard Test Conditions of 100 mW/cmz irradiance, AM 1.5 spectrum, and cell temperature of 25°C. APPLICABLE REOUIR EM ENTS ULC/ORD- C1703-01 - Flat -Plate Photovoltaic Modules and Panels UL 1703-3`d Edition - Flat -Plate Photovoltaic Modules and Panels CSA Group Certificate: 2284121 (249143) Master Contract: 249143 The products listed, including the latest revision described below, are eligible to be marked in accordance with the referenced Certificate. Product Cefl ttifle l.ttion History Project Date Description •70048197 2015-10-05 Update Report 2284121 for 1. Seven new cell technologies 2. Two new J-box tested with 13 different combinations of backsheets and adhesive 3. New J- box and frame adhesive 4. New clamping method for ZEP frame 5. Mounting on NexTracker 6.Removal of obsolete models and materials 7. Update FI frame for NexTracker and ATI trackers 8. Update HF10 test results for Boviet Solar factory 70043990 2015-09-10 Provide Report Update to add HF test results 70031273 2015-05-01 Update test report no. 2284121 for 1. Alternate EVA - ' Changshu Tegu New Material Technology Co. Ltd.', types 72014" and 72053 ", 0.45-0.5 mm nominal thickness, two sheets provided (T2014 type above cell strings - superstrate side - and T2053 type below - substrate side) 2. Alternate Substrate - (Suzhou) Sunwatt Co., Ltd. ', white type "KFB-30" overall thickness, 0.290 mm nominal. 3. Alternate Substrate -'Crown Adbanced Material Co., Ltd. ', white type "BE-D2", overall thickness, 0.390 mm nominal 4. Add new Model Series CS6P-XXXP-TD , 240 W to 275 W range, with Tigo DC optimizer 5. Alternate Jbox - 'Changshu Friends Connector Technology Co., Ltd', junction box type CF1108-03g, rated 600 V dc, 11A 6. Alternate Jbox -'Changshu Friends Connector Technology Co., Ltd', junction box type CF1108-03g b, rated 1000 V de, I IA 7. Alternate Jbox -#Tigo energy Inc.#, junction box type MMJ-ES50, with Smart Curve function, rated 1000 dc, 9.5A 8. Alternative Cables: For use with MMJ-ES50 junction boxes only, on CS6P-P-TD, NRTL approved type PV wire No. 12 AWG, rated 600 V minimum. Outer diameter 6.7f0.20 mm, 90°C minimum, marked sunlight resistant 9. Add new bypass diode 30CTQ100S (For use with MMJ-ES50 junction boxes only), rated 100v, 30A 10. Alternate mounting system - CS6X-xxxPX with ZS Peak mounting system 11. Alternate mounting system - CS6X-xxxP with Array Technology Inc, DuraTrack# HZ Solar Tracker V3 clamps and torque tube 12. Alternate grounding method - for Brilliant Rack Ground Mount System. 13. 70016938 2015-01-09 Update Report 2284121 to Include Vietnam Factory "Viva Solar Technology" 70015998 2014-12-24 Update Report 2284121 to add model CS6P-P-SD (w/Solaredge Optimizer), CS6P-P-TD(w/Tigo optimizer), four alternative cells and alternative grounding method. 20 Certificate: 2284121 Project: 70048197 s . CSA Group Master Contract: 249143 Date Issued: 2015-10-05 70013912 2014-10-30 Update Deport 2284121 to include two alternative cells and alternative grounding methods. 2761996 2014-09-24 Update Report 2284121 to add Celestica, ON as a Factory; IFENot Required 2749251 2014-07-25 Update to include alternative cells, EVA, backsheet, potting compound and grounding methods. 2725910 2014-05-15 Update Report 2284121 to include the addition of series -M and -MM and alternative construction. 2679144 2014-01-31 Add Factory "Canadian Solar Solutions Inc, London, ON". 2676999 2013-11-13 Update to include an alternative EVA, backsheet, junction box and cells. 2633572 2013-07-08 Update to include two alternative backsheets and two cells. 2618121 2013-04-19 Update to include an alternative'EVA, backsheet, junction box, junction box adhesive and cells. 2604442 2013-02-26 Update to include changes to cells, alternative EVA and addition of series CS6K. 2600055 2013-02-06 Update to include an alternative mounting system. 2594501 2013-01-17 Update to inceude alternative junction box and a number of poly and mono cells. 2584786 2013-01-03 Update to add factory "CSI Central Power". 2587786 2012-12-19 Update to include changes to cells, alternative j-box and back sheets BEC- 301 by Hangzhou First and VTPEIRW by Taiflex. 2559421 2012-09-26 Update to include the addition of Flexcon KPE backsheet. 2542034 2012-07-06 Update to include new half cell modules series PT, addition of 1000 V rating, alternative j-boxes and adhesive. 2496460 2012-06-15 Evaluation to add backsheet from COVEME for all the module series (with F806 EVA, CM0804 junction box and Tonsan 1527 adhesive). 2515777 2012-06-12 Update to include the evaluation of factory location in South Korea (includes HF 10 test sequence). 2532459 2012-06-05 Update to include new models (smaller modules), alternative cells and backsheets. 2512339 2012-03-28 Update to include alternative cells. 2508436 2012-03-21 Update to include three alternative cells and an alternative Toyo back sheet. 2490216 2012-01-13 Update to add CSSP-xxxP and CSSA-XXXP Series. 2458713 2011-12-19 Evaluation for an alternative (Shunfeng) cell and j-box with Isovolta AAA backsheet with PV744 adhesive. 2480024 2011-12-01 Evaluation for alternative JA Solar cells and to add new series. 2 F? �' CSA Group Certiffacateo 2284121 Project: 70048197 Master Contract: 249143 Date Issued: 2015-10-05 2470474 2011-10-28 Update to add the laminates (without frame). 2455625 2011-09-02 Update to add smaller modules with cut cells. 2441645 2011-07-26 Update to include change in glass dimensions, black backsheet, new frame and new j-box and edgeseal adhesive. 2431019 2011-06-03 Update to include the addition of model series CS6A and use of alternative mateirals and components. 2404638 2011-04-18 Update to include an alternate lamination line, includes HF10 test sequence. 2390337 2011-02-08 Addition of factory location in Ontario. 2380821 2010-12-17 Update to include Model Series CSSA-XXXM and CSST-XXXM. 2284122 2010-10-14 Addition of 72 cell series CS6X-XXXP and CS6X-XXXM. 2284121 2010-06-30 Evaluation of PV Panel Series for C/CSA/US Mark. 7/29/2015 4 Certified Product Listing - 2541411 Certified Product Listing I CSA Group Region English CSA 9Careers News Contact Us ':rtar sel'cm Sr -arch r...' .. Group 4 ry' HOME ABOUT SERVICES INDUSTRIES SHOP CSA Home Services Testing & Certification Certified Product Listing 254141 Certification Record Customer Class File Number Hanwhe Q.CELLS 5311-90 254141 GmbH POWER SUPPLIES -Photovoltaic Modules and Panels - Certified to US 17-21 Sonnenallee, Standards Bitterfeld-Wolfen Saxony-Anhalt 06766 Germany Photovoltaic Modules with maximum system voltage of 1000 V dc, and Class C fire class rating and Module Fire Performance: Type 1, Model Series Q.BASE GY XXX; Q.PRO-GY XXX; Q.PLUS-GY XXX; Q.PRO BFR-GY XXX; Q.PRO BLK-GY XXX; Q.PRO - GY/SC XXX; MODULE GY XXX; MODULE BFR-GY XXX; MODULE BLK-GY XXX; B.LINE PRO-GY.Y XXX, B.LINE PRO-GY XXX; B.LINE PLUS-GY XXX; B.LINE PRO BFR-GY XXX, B.LINE Q.PRO - GY/SC XXX where XXX is the power output from 205 W to 295 W; Q PRO-GY.Y XXX where XXX is the power output from 245 W to 285W, Q.PEAK XXX, Q.PEAK - GY XXX and Q.PEAK BLK XXX, Q.PEAK BLK - GY XXX; MODULE M-GY XXX, where XXX is the power output from 245 W to 295 W and Q.PRO L XXX; Q.PRO L - GY XXX; MODULE L XXX where XXX is the power output from 280 W to 335 W (in steps of 5 W) with the following electrical ratings typical at 230 W for Q.BASE/Q.PRO/MODULE G3, 270 W for Q.PLUS-G3, 240 W for Q.PRO BFR-G3/Q.PRO BLK-G3/MODULE BFR - G3/MODULE BLK - G3, 270 W for Q PRO-G4.1, 245 W for Q.PEAK-G3/MODULE M-G3 and 300 W for Q.PRO L/MODULE L respectively @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 36.13 /38.86/38.16/36.81/37.24/45.27 V Short Circuit Current (Isc): 7.96/9.48/8.82/8.3418.33/8.93 A Operating Voltage (Vpmax): 30.72/30.78/31.3130.74/30.85/36.27 V Current at Operating Voltage (Ipmax): 7.57/8.85/8.62/7.89/7.86/8.34 A Notes: 1. Rated electrical characteristics are within +/-10% of measured values at Standard Test Conditions of 100 mW/cm2 irradiance, AM 1.5 spectrum, and cell temperature of 25°C. 2. 'Y' in the model number denotes the generation number between 1 and 9. 3. All modules are qualified for heavy accumulations (5400 Pa) of snow and ice. Photovoltaic Modules with Class C fire class rating, Model Series Q. PRO L XXX where XXX is the power output from 280 W to 310 W with maximum system voltage of 1000 V do and the electrical ratings as specified below at Standard Test Conditions. Electrical ratings: Model Open Circuit Rated Voltage Rated Current Short Circuit Rated Maximum Voltage (V dc) (V dc) (A dc) Current (A dc) Power (Watts) Q. PRO L 280 44.7 35.1 7.98 8.47 280 Q.PRO L 285 44.8 35.2 8.10 8.56 285 Q.PRO L 290 45.0 35.4 8.20 8.65 290 Q.PRO L 295 45.2 35.6 8.29 8.73 295 Q.PRO L 300 45.4 35.8 8.38 8.82 300 Q.PRO L 305 45.5 36.1 8.45 8.90 305 http://www.esagroup.org/global/entservices/testing-and-certificationlcertified-product-listinglcertficate/254141 %257C5311-90 1/2 Ir This family of single-phase string inverters complements the typical number of rooftop solar panels enabling homeowners to get the most efficient energy harvesting for the size of the property. This inverter offers a dual input section that processes two strings with independent Multiple Power Point Tracking (MPPT). This is especially useful for rooftop installations with two different orientations from two sub -arrays oriented in different directions, or unbalanced strings (for example: East and West). The dual -input sections with independent MPPT enable a more optimal energy harvesting condition. The high -,speed MPPT offers real- time power tracking and improved energy harvesting. The flat efficiency curve ensures high - efficiency at all output levels allowing a consistent and stable performance across the entire input voltage and output power range. The transformerless operation gives the highest efficiency of up to 97.0 percent. The wide input voltage range makes the inverter suitable to low -power installations with reduced string size. This rugged, outdoor inverter has been designed to be a completely sealed unit, to withstand the harshest environmental conditions. Highlights — Single-phase and three-phase output grid connection — Wide input -voltage range for increased stringing flexibility and energy harvesting — The high-speed and precise MPPT algorithm offers real-time power tracking and improved energy harvesting — Outdoor NEMA 4X rated enclosure for unrestricted use under any environmental conditions — Integrated DC disconnect switch in compliance with international Standards (-S Version) Power and productivity A ®II ®il for abetter world"' JIMP ®® Additional highlights — RS-485 communication interface (for connection to laptop or data logger) — Available with the optional VSN300 Wifi Logger Card for easy and affordable wireless monitoring — Compliant with NEC 690.12 when used with ABB`s Rapid Shutdown device — Comes standard with DC Arc Fault Circuit Interruptor (AFCI) to comply with NEC 690.11 Technical data and types Type code PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US PVI-4.2-OUTD-US General specifications ' Nominal output power 3000W 3600W 3W0 3800W 4200W 3000 3300' 3300' 3600 4000' 4000' 3300 4200' 4200' * 4200 4600' ' 4600' Maximum output power wattage W W W W W W W W W W W W Rated grid AC voltage 208V 240V 277V 208V 240V 277V 208V 240V 277V 208V 240V 277V Number of independent MPPT channels 2 2 2 2 Maximum usable power for each channel Absolute maximum voltage (Vmax) .2000W. .3000W. .3000W. 600V .3000W. Start-up voltage (Vstart) 200V (adj. 120-350V) Full power MPPT voltage range 160-530! 120-530V 140-530V 140-530V Operating MPPT voltage range 0.7 x Vstart - 580V (>_90V) Maximum current (ldcmax) for both MPPT in 20A 32A 32A 32A parallel Maximum usable current per channel 10A 16A 16A 16A Maximum short circuit current limit per 12.5A 20.OA 20.OA 20.OA channel Number of wire landing terminals per channel 2 pairs Array wiring termination Terminal block, pressure clamp, AWG20-AWG6 'Output side (AC) Grid connection type 10/ Split- 10/ 10/ Split- 10/ 10/ Split- 10/ 10/ Split- 10/ 2W 0/3W 2W 2W 0/3W 2W 2W 0/3W 2W 2W 0/3W 2W Adjustable voltage range (Vmin-Vmax) (V) 183- 211- _ 244- 183- 211- 244- 183- 211- 244- 183- 211- 244- 228V 264V 304V 228V 264V 304V 228V 264V 304V 228V 264V 304V Grid frequency 60Hz Adjustable grid frequency range 57-60.5Hz Maximum current (1.,ma) 14.5A 14.5A 12.OA 17.2A 16.OA 16.OA 16.OA 16.OA 16.OA 20.OA 20.OA 20.OA Power factor > 0.995 (adjustable to t0.8) Total harmonic distortion at rated power < 2% Grid wiring termination type Terminal block, Pressure clamp, AWG20-AWG6 Input protection devices Reverse polarity protection Yes Over -voltage protection type Varistor, 2 for each channel PV array ground fault detection Pre start-up R,, and dynamic GFDI (requires floating arrays) Output protection devices Anti-islanding protection Meets UL1741 / IEEE1547 requirements Over -voltage protection type Varistor, 2 (L, - Lz / L, - G) Maximum AC OCPD rating 20A 20A 15A 25A 20A 20A 20A 20A 20A 25A 25A 25A Efficiency Maximum efficiency 96.9% 97% 97% 97% CEC efficiency 96% Operating performance Nighttime consumption < 0.6WRMs Stand-by consumption < 8W._ Communication User -interface 16 characters x 2 lines LCD display Remote monitoring (1XRS485 incl.) VSN700 Data Logger (opt.), VSN300 Wifi Logger Card (opt.) Environmental Ambient air operating temperature range -130F to +140OF (-25°C to 60°C) with derating above 122°F (50°C) Ambient air storage temperature range -40OF to +1760F (-40°C to +80°C) Relative humidity 0-100% RH condensing Acoustic noise emission level < 50 db (A) @1 m Maximum operating altitude without Berating 6560ft (2000m) 1. Capability enabled at nominal AC voltage and with sufficient DC power available. 2 ABB solar inverters I Product flyer for PVI-3.0/3.6/3.8/4.2-TL-OUTD Block.diagram of PVI-3.0/3.6/3.8/4.2-TL-0UTD --------------------------------------- -----------------------------------------------------------------------------• MPPT 1 (DUDQ BULKCAPS INVERTER (DUAL) LINE I GRID PARALLEL ' FILTER RELAY I IN1.2(+) 1 pro— Lt , INI INI INI INI 1 INI INI ---I lyrl I I ' I I N I i IN1.2(-) DC AFDI I r _ I I MPPT2 (DC/DQ J j L$ IN2.2(+) IN2 ' i RESIDUAL CUpRENT ' I I DETECTION IN2 IN2 IN2 IN2 I ' IN2 I I I I PE IN2.1 (•I ' -d ' ? . R5485 - _ +T/R IN211-1 .7/fl WIRING BOX - -- -t- - - - - ------ ----i----- ----- - - - - - - a REMOTE CONTROL•' 6 .____ •___________ DSP CONTR DSP CONTR ' +R GROUND FAULT ❑ N p - R DETECTION ALARM , N.0 N.0 - - CONTROL CIRCUIT C L_____________________________________________________________________________- Remote control function not available on -A version PVI-4.2-OUTD-US 340 Vdc — 9 91 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% loft% of Rated output Power PVI-4.2-OUTD-US 50� 96A mAocs romn cu ss moc a uw+s w ssar su samw ssaws °}A 315 250 300 3�5 <OJ d80 uvrrwluwm Technical data and types Type code PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US PVI-4.2-OUTD-US Mechanical specifications rat 4X ..Enclosure ........................................................................................................................................................................................NEMA Cooling ........................................................................................................ Natural convection ................................................................................................................................ Dimensions H x W x D ............................................................................................................................................................................................................................................................. .......................................................................................................................................... 33.8 x 12.8 x 8.7in (859 x 325 x 222mm)? Wei�ht................................................................................................................................................................................................<47.31b (21.3kg)................................... ............................ ................. Shippingweiht..................................................................................... ......... ................................................................................< 601b (27Oki)Z......................................... Mountingsystem bracket ...............................................................................................................................................................................Wall Bottom: (2) pre -drilled opening for 3/4 inch conduits and concentric markings for 1 inch (both sides) and 11/2 inch conduit (DC side only) Conduit connections2 Sides: (2) pre -drilled opening for 3/4 inch conduits with concentric markings for 1 inch (both sides) and 11/2 inch conduit (DC side only) ................................Back:..(). concentric markings for 3/4 inch and..1..inch conduits................................. DC switch rating (per contact) (AN) 25/600 Safety and Compliance I Isolation level ............................. .............................................................................................. Transformerless (floating array) ........................................................................................................................... Safety and EMC standard 1JL1741, UL1741 SA (draft), IEEE1547, IEEE1547.1, CSA-C22.2 N. 10.7.1-01, (JL1998.11L ......................................................................................................-..........................:............................ 1699B, FCC Part 15 Class B .............................................................................. Safety approval ............................................................................. �CSkI or JUV. ................................................................................................................................................................................... Regional Compliance :Rule 21, HECO, NEC 2014 690.11, NEC 2014 690.12 with ABB Rapid Shutdown device Available models With DC switch, wiring box, arc fault detector and PVI-3.0-OUTD-S- PVI-3.6-0UTD-S- PVI-3.8-OUTD-S- s PVI-4.2-OUTD-S- interrupter US -A US -A US -A US -A 2. When equipped with optional DC switch and wiring box All data is subject to change without notice Product flyer for PVI-3.0/3.6/3.8/4,2-TL-OUTD I ABB solar inverters 3 Support and service ABB supports its customers with a dedicated, global service organization in more than 60 countries, with strong regional and national technical partner networks providing a complete range of life cycle services. For more information please contact © Copyright 2015 ABB. All rights your local ABB representative or visit: reserved. Specifications subject to change without notice. www.abb.com/solarinverters 0 ''M www.abb.com AicpTOVRheinland c us C us This inverter is marked with one of the two certification marks shown here (TuV or CSA). Power and productivity A It ,t for a better world TM P P ®. Ct�1A SN. AGK STANt - Alai' SPLIT WAS W Ili FLAT ItA' bl 3.5' MINIMUM • �- t .F FLA$H Pit ? \m .STAN MRD UALVAKe SUEL up DEAD SOFT ALUM" - 5/16' LAG I :TS MST EHM Rt3C1F' FLAMM FM aW INTO RMF STkWTbnAL 8 1' VIAMET-rg VENT Pjft WINKR8/RAFTEI SNOT 3mwto - TORQUE ALL i" HARDWARE TO THE F'ALLGWING� - �, - SILVER S.S..38-16 FT�LBS $LACK S.S. 7-9 FT-L.88 e -RAILS CAN W-M, TO l IT11- S1. OF;Pi)S7 <l•$'SL�PE VS� �1IIMIN51.tt� SNAPt1RACK -RAILS CAN tE LEVY Lip 713 f? l�R T FLASHING At * HOkN IN SERSINd UP TO 7VO VES 1 RM MMING' SN AW &TANDWF SHAFT STD (;NARMUS SIMS) CX 1 Ss. 19g�1�i4. AN 5s. SPLIT VAsta 8 T•ALLt b tFUR, PAK $I119 EiP SYAftWi~ 13AM PRIM TO INSTALLAT-MN ON t2C1W SNAPORAGK STAND P EASE STD 1-Hfte SEAL, PPKYRATION AND U1Mft BASE WITH APPROPPIAM R56F SEALANT lllo� . SNAi'NRAt-';X S`CAN$[ rP UN' IN(, Ptilti FM USE FIN ALL AtM , UgFACES Rini' riECKIt . Typ. PEN-002 PUN bF.TAIL 02 A.Nbbpr t SCOPE OF WORK I GENERAL NOTES • SYSTEM SIZE: 5035W DC, 460OW AC . ALL WORK SHALL COMPLY WITH 2O13 CEC, 2013 CBC, CRC 2013, MUNICIPAL • MODULES: (19) CANADIAN SOLAR: CS6P-265P CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION • INVERTER(S): INSTRUCTIONS. (1) ABB: PVI-4.2-OUTD-S-US-A (240 V) • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2O13 CEC. • RACKING: SNAPNRACK SERIES 100 UL; FLUSH MOUNT • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH 2O13 CEC. STANDOFF. SEE PEN D02. • PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35. • EXISTING SOLAR SYSTEM INSTALLED. • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(E) AND 2012 IFC 605.11.2. • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. • 9.23 AMPS MODULE SHORT CIRCUIT CURRENT. • 14.42 AMPS DERATED SHORT CIRCUIT CURRENT (690.8 (a) & 690.8 (b)). VICINITY MAP dd r n r i o A a 1T" LEGEND AND ABBREVIATIONS SE SERVICE ENTRANCE MP MAIN PANEL Rl SUB-PANEL F0_1 PV LOAD CENTER SM SUNRUN METER PM DEDICATED PV METER INVERTER(S) WITH NV F INTEGRATED DC DISCONNECT AND AFCI AC AC DISCONNECT(S) L DC DISCONNECT(S) CB COMBINER BOX I— -1 LEa INTERIOR EQUIPMENT SHOWN AS DASHED SOLAR MODULES RAIL 0 0 o — STANDOFFS & FOOTINGS N�l CHIMNEY TABLE OF CONTENTS PAGE # DESCRIPTION PV-1.0 COVER SHEET PV-2.0 SITE PLAN PV-3.0 LAYOUT PV-4.0 ELECTRICAL PV-5.0 SIGNAGE ATTIC VENT Zr r FLUSH ATTIC" 1005 9 INO o PVC PIPE VJq ® METAL PIPE ' a; k"�l�9 , b ® T-VENT REVIEWED=00ZXLQ& 0MP IANCE SATELLITE DISH Review .d By - Rpm rcF E. ce HARDSCAPE — PL— PROPERTY LINE SCALE: NTS A AMPERE AC ALTERNATING CURRENT AFCI AZIM ARC FAULT CIRCUIT I . FR �UPTER ��1�71R �.1Y AZIMUTH NI DE77ELOPr,4EJT DEPFAR' BUILDING tDiv`I�iCii�i COMP COMPOSITION - CUPtRTIN DC DIRECT CURRENT r' " $ED iz (E) EXISTING Th!z5 cr?t of 111a;1g and OP 001f!Cationc EXT n%,UST EXTERIOR job GOII0Vaction. It is �n!avffui FRM INT FRAMING cis ;; ; or alias: ions on sa;r INTERIOR to tho��;�rum, LBW withoutsPPrcval frOfll'i}l@�rJO LOAD BEARING WALL j MAG MAGNETIC Tn" st:-mPit n cf this P!a;� - MSP ,.IilCu,ltiil� MAIN SERVICEIPANLLio P I-mit or to (N) NTS NEW of any Provisions of any Cijy Or ;iE �anae or NOT TO SCAhF OC ON CENTER C PRE-FAB PRE-FABRICATE,D,,...— ,3 • �G •l 4-� �. PSF POUNDS PER aQWAR,,E FOOT - CKED RV PL� PV PHOTOVOLTAIC TL TRANSFORMERLESS TYP TYPICAL r ®�� � 3 .201 DATE V VOLTS EPT PLANNING D_ W WATTS REV NAME DATE COMMENTS ry CUPERTINO A sunrun GILBERT CORREIA, C10, C46 #750184 2300 ZANKER ROAD, UNIT F, SAN JOSE, CA 95131 PHONE 408.746.3062 FAX 408.894.9294 CUSTOMER RESIDENCE: OBERv MERRICK � l =~. Off RD, 'C�IPER INO, CA, 95014 r n,� 08) 446-1168 APN #: 32616064 � R.OJ:EQT NUMBER: 102R-190MERR DESIGNER: MICHAELA FLEMING 949.705.3956 IDRAFTER: RBIEL1 I SHEET COVER SHEET REV: A 3/25/2016 PAGE PV-1.0 UE MAG EA SITE PLAN - SCALE = 3/64" = 1'0'• PITCH AZ M AZIM P(SQFRT) ® AR-01 18° 89° 75° 104 AR-02 18 8890 750 225.3 MP SE SM AC LC INV PL P PL PL PL (N) ARRAY AR-02 � d d a 32' a g p p'� d d �a-�``�� Rpail' dirty. � /r ; Dep, nd 93'-1 11 m a 63'-10" A REVIEWED FOR CODE COMPLIANCE � d d (N) ARRAY AR-01 Revidawed By: c r ❑ d 4 sunrun dd oo GILBERT CORREIA, C10, C46 d CA CL #750184 (E) RESIDENCE A� 2300 ZANKER ROAD, UNIT F, SAN JOSE. CA 95131 PHONE 408.746.3062 29'-8" FAX 408.894.9294 4 d d c CUSTOMER RESIDENCE: ROBERT MERRICK PL PL PL PL PL PL PL 10190 HILLCREST RD, CUPERTINO, CA, 95014 (E) SOLAR SYSTEM TEL. (408) 446-1168 APN #: 32616064 PROJECT NUMBER: FIRE SETBACKS 102R-190MERR (3' TYP) DESIGNER: MICHAELA FLEMING 949.705.3956 DRAFTER: RBIEL1 SHEET SITE PLAN REV: A 3/25/2016 PAGE PV-2.0 ROOF TYPE ATTACHMENT ROOF HEIGHT ROOF FRAME FRAME TYPE FRAME MAX FRAME 0C ROOF EDGE MAX RAIL MAX RAIL DESIGN CRITERIA EXPOSURE MATERIAL SIZE SPAN SPACING ZONE SPAN OVERHANG MODULES: CANADIAN SOLAR: CS6P-265P AR-01 CONCRETE TILE [CURVED] FLUSH MOUNT STANDOFF. SEE PEN D02. SINGLE STORY VAULTED WOOD RAFTER 2 X 8 15' - 0t1 24" 31 - 011 6' - 01' 2' - 0" AR-02 CONCRETE TILE [CURVED] FLUSH MOUNT STANDOFF. SEE PEN D02. SINGLE STORY VAULTED WOOD RAFTER 2 X 8 151- 0" 24" 3' - 011 6' - 0" Z - 011 MODULE DIMS: 64.5" x 38.7" x 1.57" D1 - AR-01 - SCALE: 1/8" = V-0" MODULE CLAMPS: PITCH: 180 Portrait: 13.39" - 16.14" AZIM: 89° Landscape: 7.87" - 9.84" ® 1'-6" MAX DISTRIBUTED LOAD: 3 PSF —3'— 19'-611 —6'-6"— SNOW LOAD: 0 PSF WIND SPEED: 110 MPH 110 MPH 3-SEC GUST. LAG SCREWS: 31 ' ' I 3' 5/16"x3.5": 2.5" MIN EMBEDMENT NOTE: Al - I INSTALLERS TO VERIFY RAFTER 5-411 —6 TYP 41 ( I I I —4 ! SIZE, SPACING AND SLOPED SPANS, AND NOTIFY E.O.R. OF j 10'-911 ANY DISCREPANCIES BEFORE PROCEEDING. roo CCU PERTINO ng DeF artment 1 MAR 3 0 2016 2 X 8 RAFTER 11 24 OC +.w-.a._ d REVIE ED Fok COME COMPLIANCE Re i6wed B D2 - AR-02 - SCALE: 1/8" = V-0" PITCH: 180 sunrun AZIM: 890 ROOF FRAMING DETAIL -SCALE: NTS ® 9'-9" RIDGE BOARD GILBERT CORREIA, C10, C46 CA CL #750184 2300 ZANKER ROAD, UNIT F, SAN JOSE, CA 95131 PHONE 408.746.3062 FAX 408.894.9294 I 5/16" X 3.5" LAG SCREW. 3' 1 BOLT PER PENETRATION CUSTOMER RESIDENCE: CONCRETE TILE [CURVED] ROOF ROBERT MERRICK SOLAR MODULE 10190 HILLCREST RD, lo —4'— CUPERTINO, CA, 95014 oo oo TOP PLATE TEL. (408) 446-1168 APN #: 32616064 PROJECT NUMBER: oo oo { I 16-211 2X8 RAFTERS, 24" O.C. 102R-190MERR DESIGNER: LOAD BEARING WALL MICHAELA FLEMING 949.705.3956 DRAFTER: RBIEL1 SHEET LAYOUT 2 X 8 RAFTER 24" OC REV: A 3/25/2016 PAGE PV-3.0 ti 120/240 VAC SINGLE PHASE ABB: PVI 4.2-OUTD-S-US-A 1 PV MODULES SERVICE (240 V) f CANADIAN SOLAR: CS6P-265P O METER #: PG&E 1009935472 4200 WATT INVERTER 2 JUNCTION BOX OR EQUIVALENT +�l/ (9) MODULES (1) STRING OF (9) MODULES UTILITY GRID EXISTING P PV MODULES 1 400A MAIN (N) 125A PV LOAD _—__ �f' CBREAKER CENTER CANADIAN SOLAR: CS6P-265P (END FED) DUAL MPPT STRING 2 +(�/ (10) MODULES OF 1 COMBINER & LOAD 1 (1) STRING (10) MODULES EXISTING 3 RATED DC DISCONNECT 400A (N) LOCKABLEMAIN ~ FACILITY PANEL (N) SUN RUN METER BLADE TYPE AC DISCONNECTF EXISTING SYSTEM LOADS POWER ONE: PV MODULES 4 4 4 E PV I-4.2-0 UTD-S-U S-Z TRINA SOLAR __. 4200 WATT INVERTER JUNCTION Box (10) MODULES R EQUIVALENT OPJ:G^0,(10) (1) STRIMODUL`��5�'� a �'� FACILITY 50A PV GROUND 250V METER SQUARED 25A BREAKER (A)- ��5r•' Y BREAKER AT SOCKET DU222RB 25A BREAKER (B) ( _— o---•� PV MODULES 0,„; OPPOSITE END 125A CONTINUOUS 3R, 60A,2P TRINA SOC4R OF BUSBAR & 240VMETER 120/240VAC I + -� t-:�. - - (11) P�g�i�.t t-��� .'" E COPVIP�IA�NCE STRING OF MODiUCSJ 200A, FORM 2S (1) (11) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (2) 10 AWG PV WIRE NONE (1) 10 AWG BARE COPPER 2 3/4" EMT OR EQUIV. (2) 10 AWG THHN/THWN-2 NONE (1) 8 AWG THHN/THWN-2 3 3/4" EMT OR EQUIV. (2) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 4 3/4" EMT OR EQUIV. (2) 6 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 1 (1) 8 AWG THHN/THWN-2 MODULE CHARACTERISTICS CANADIAN SOLAR: 265 W CS6P-265P OPEN CIRCUIT VOLTAGE 37.7 V MAX POWER VOLTAGE 30.6 V SHORT CIRCUIT CURRENT 9.23 A SYSTEM CHARACTERISTICS - INVERTER 1 SYSTEM SIZE 5035 W SYSTEM OPEN CIRCUIT VOLTAGE 492 V SYSTEM OPERATING VOLTAGE 367 V MAX ALLOWABLE DC VOLTAGE 600 V SYSTEM OPERATING CURRENT 17.32 A SYSTEM SHORT CIRCUIT CURRENT 23.08 A NOTES TO INSTALLER: 1. 452 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE. 2. ADD 125 AMP LOAD CENTER 3. ADD (1) 2P 25 AMP BREAKER TO LOAD CENTER FOR EXISTING SOLAR SYSTEM, AND (1) 2P 25 AMP BREAKER TO LOAD CENTER FOR NEW SOLAR SYSTEM. 4. ADD (1) 50 AMP BREAKER TO MAIN PANEL FOR NEW LOAD CENTER. 6-12 AWG BARE 5/16"-18 SS BOLT COPPER WIRE SS SPLIT LOCK WASHER / — (TORQUE TO 16 FT-LBS) \ SNAPNRACK \ GROUND LUG ri BONDING \ \ CHANNEL NUT SS BONDING RAIL PINS NOTE: • ALL HARDWARE IS INCLUDED FROM MANUFACTURER • A MINIMUM OF ONE GROUND LUG IS TO BE INSTALLED ON EVERY CONTINUOUS ROW OF MODULES • GROUNDING LUG MAY BE INSTALLED IN EITHER RAIL CHANNEL • GROUNDING LUG MAY BE INSTALLED SO GROUND WIRE IS PARALLEL OR PERPENDICULAR TO RAIL • ENSURE SPLIT LOCK WASHER IS INSTALLED ON TOP OF COPPER WIRE SNAPNRACK GROUNDING SCALE: NTS PER CODE: 690.52 A -s LABEL LOCATION: DC DISCONNECT, INVERTER (PER CODE: CEC 690.35(F)) [To be used when inverter is ungrounded] I ARFI I r)r`AT1C)K1- AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: CEC 690.17(E)) LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION PER CODE: CEC 690.17(E), CB LABEL LOCATION: INVERTER, JUNCTION BOXES (ROOF), AC DISCONNECT (PER CODE: CEC690.13.G.3 & CEC 690.13.G.4) INVERTER 1 LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: CEC690.54) LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: CEC 705.12(D)(7)) [Not required if panelboard is rated not less than sum of ampere ratings of all overcurrent devices supplying it] LABEL LOCATION: WEATHER RESISTANT MATERIAL, DURABLE ADHESIVE, UL969 AS STANDARD TO WEATHER RATING (UL LISTING OF MARKINGS NOT REQUIRED), MIN %" LETTER HEIGHT ARIAL OR SIMILAR FONT NON -BOLD, PLACED WITHIN THE MAIN SERVICE DISCONNECT, PLACED ON THE OUTSIDE OF THE COVER WHEN DISCONNECT IS OPERABLE WITH SERVICE PANEL CLOSED. (PER CODE: CEC690.15, 690.13(B)) LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: CEC 705.12(D)(4)) LABEL LOCATION: CONDUIT, COMBINER BOX LABEL LOCATION: (PER CODE: CEC690.31(G)(3)(4) & CEC 690.13(G)(4) MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES, + fLLq AND CABLE ASSEMBLIES AT LEAST EVERY 10 FT, AT TURNS AND ABOVE/BELOW PENETRATIONS a �jt�� €€ AND ALL COMBINERMUCTION BOXES. (PER CODE: IFC605.11.1.4) ' t. E s I rtrr SOLAR DISCONNECT N �r LABEL LOCATION: REV DISCONNECT, POINT OF INTERCONNECTION iEl. 'E�� �Jk �':ii�E COMPLIANCE (PER CODE: CEC690.13(B)) CAUTION.i� VI�Wetj a�: ��,-1�� POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE ALL GNAGE SHALL BE RED PLASTIC FOLLOWING SOURCES WITH ENGRAVED WITH 1/2" HIGH WHITE LETTERS. DISCONNECTS AS SHOWN LABEL LOCATION: DC DISCONNECT, INVERTER (PER CODE: CEC690.53) ADHESIVE FASTENED SIGNS: • THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. • WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS, AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4 [NEC 110.21(B) FIELD MARKING]. • ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.1.31 SOLAR PANELS ON ROOF (5 SERVICE ENTRANCE AND PV EB _ BREAKER DISCONNECT SUNRUN METER AC DISCONNECT PV LOAD CENTER INVERTER LOCATION 10190 HILLCREST RD, CUPERTINO, CA, 95014 E3