Loading...
B-2016-1657CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO:B-2016-1657 10808 JUNIPER CT CUPERTINO, CA 95014-6556 (342 57 007) SUNRUN INSTALLATION SERVICES INC SAN LUIS OBISPO, CA 93401 OWNER'S NAME: ERDMAN WILLIAM D TRUSTEE & ET AL DATE ISSUED: 03/30/2016 OWNER'S PHONE: 650-964-3966 PHONE NO: (888) 657-6527 LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO: License Class C46 Lic. #750184 Contractor SUNRUN INSTALLATION SERVICES INC Date 06/30/2016 X BLDG —ELECT —PLUMB MECH X RESIDENTIAL COMMERCIAL I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. JOB DESCRIPTION: INSTALLATION OF ROOF MOUNTED SOLAR (23 PANELS)(5.0 kW). I hereby affirm under penalty of perjury one of the following two declarations: 1. 1 have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. +r,, r; �,;1 2. 1 have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this Sq. Ft Floor Area: Valuation: $10500.00 permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances APN Number: Occupancy Type: and state laws relating to building construction, and hereby authorize 342 57 007 R3 representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which PERMIT EXPIRES IF WORK IS NOT STARTED may accrue against said City in consequence of the granting of this permit. WITHIN 180 DAYS OF PERMIT ISSUANCE OR Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino unicipal Code, Section 9.18. 180 DAYS FROM LAST CALLED INSPECTION. ignature Date 3/30/16 Issued by: SEAN HATCH��� Date: 3/30/16 lv OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: 1. I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) 2. I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (See.7044, Business & Professions Code). I hereby affirm under penalty of perjury one of the following three declarations: 1. I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2. 1 have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. APPLICANT CERTIFICATION !F77` I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. RE -ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. Signature of/ Date; 3/30/16 ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER HAZARDOUS MATERIALS DISCLOSURE I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Sections 25505, 25533, and 2 4. Owner or authorized agent: Date: 3/30/16 CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name Lender's Address ARCHITECT'S DECLARATION I understand my plans shall be used as public records. Signature Date 3/30/16 Licensed ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • buildinga.cuoertino.org �' �� �� • %gyp f 7 PROJECT ADDRESS id o Q u &NtpeF4 ^ ,� � � I APN R 3 `2-5,7 -76o -7 OVJ�cRNA14E ) a 1I W M P' F-" iVj,A-jV I PHONE(6 -5) ,?64- G E-MAIL STREET ADDRESS d�d CITY, STATE, ZIP JZWIP� � �f' dVP�o C,P'r✓ is6! FAX CONTACT NAME ,p iJ PHONE E-D�iAIL Svc ,c/ zMe `:31 35ZO MV524 S TRE.ET ADDRESS � � � < U CITY, STATE, ZIP I FAX cl6" j Cn�;e—. CA` ❑ owm-ER ❑ o%vr,.-R-BUII.DER ❑ 01WERAGElv7 ❑ CONTRACTOR 401T kACTORAGE1hT ❑ ARC.= --CT ❑ ENGINEER ❑ DEVELOPER ❑ i'cNAhT CONTRSCTORNA? E imry c, EEGT4BER LICENSET PE BUS. / COMIPANY NAMIZ .57 E-MAIL /P �U U�1U • FAX STREET ADDRESS �3 .5 CITY, STATE, ZIP 5� zjosc-= as,o� PHONE y3� 3s ARCHITECTiENGINEER NP.111? LICENSE N-JI"BER I BUS. LIC R COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHOXH USE OF SFD or Duplex ❑ Multi -Family PROTECT IN WILDLANTD PROJECT IN STRUCTURE: ❑ Commercial URBAN INTERFACE AREA ❑ Yes ❑ NO FLOOD ZONE ❑ Yes ❑ NO OLAR PANELS ❑ ELECTRIC VEHICLE C ,RGING STATION ❑ SOLAR WATER' I'EATING ❑ OTHER: FOR SOLAR FAMELS. NUMBER OF PAN7ELS/L'NITS: KILOWATTS (COMMERCI.AL ONLlo: TOT VALUATION: DESCRIPTION OF WORK RECFI� tD BY s By my signature below, I certif�, to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. I have read this application and the information I have provided is correct. I have read the Description ofWork and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to building construction. I authorize representatives of Cupertino to enter the above-i entified prope, for inspection purposes. S igna ure of ApplicanJAgent:- Dater !� SUPPLEMENTAL INTFORAIATION RE UIRED Q =-= __ OVFI2THE COIJN�'E}; r i to _ a 1 3 PRE$S 25 a ZSRGE Pi!4pp_2011.doc revised 03116111 SMOKE /CARBON MONOXIDE ALARMS FILE OWNER CERTIFICATE OF COMPLIANCE NMI I COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION CV PERT IN+ 0 10300 TORRE AVENUE CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building(d)cugertino.org Addr-e-ss f# ofrms Srnoe? -,�—CarbonMono;icle PURPOSE This affidavit is a self -certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R314, 2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single-family and multi -family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds $1000.00, CRC Section R314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations: AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of the bedroom(s) X X On every level of a dwelling unit including basements X X Within each sleeping room X Carbon Monoxide alarms are not required in dwellings which do not contain fuel -burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. Power Supply: In dwelling units with no commercial power supply, alarm(s) may be solely battery operated. h--t existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl space. Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2. An electrical permit is required for alarms which must be comnected to the building wiring. As owner of the above -referenced property, I hereby certify that the alarm(s) referenced above has/have been installed in accordance with the manufacturer's instructions and in compliance with the California Building and California Residential Codes. The alarms have been tested and are operational, as of the date signed below. have read and agree to comply with the terms and conditions of this statement Qwner ¢oi- Owner�AgenYs) Name: Si natu i..._....... ''°`................... -Co'nfrac otName; i � �3 i r n f ra uu s :....... ......... ............................... L4c ...� '"1........ —Smoke and COforntdoc revised 03118114 CUPERTINO Owner N WATER -CONSERVING PLUMBING FIXTURES OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT o BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 e FAX (408) 777 3333 - buildingAcupertino.org PrNA EKD M h:111 Permit Non ) `� 0 FILE Address JKJ I p 1. Is your real property a registered historical site? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. K No Go to Question 2. 2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its plumbing, installation of water -conserving plumbing fixtures is not technically feasible? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. ❑ The licensed plumber's certification has been provided to the Building Division, Skip the rest of the form and sign bottom of form. f No Go to Question 3. 3. Is water service permanently disconnected for your building? Yes Civil Code Sections 1101.1 through 1101.8 do not apply.. Skip the rest of the form and sign bottom of form. No Go to Question 4, 4. Is your real property built and available for use or occupancy on or before January 1, 1994? ❑ No My real property is built and available for use or occupancy after January 1, 1994. Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. UYes My real property is built and available for use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101.8 apply. Check one of the three following statements and sign bottom of form.. _ 5. Please check ONE of the following: J J Xl M roe is a single-familyresidential real roe See Civil Code Section 1101.4. Y property rt3' � property. rtY• On and after January 1, 2014, building alterations or improvements shall require all non -compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non- compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements), 0 My property is a multifamily residential real property. See Civil Code Section 1101.5: On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non -compliant plumbing fixtures shall be replaced with water conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). ❑ My property is a commercial real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non -compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). I, as the owner or owner's agent of this property, certify under penalty of perjury that non -compliant plumbing fixtures will be replaced prior to date specified above with water -conserving plumbing fixtures in accordance with Civil Code Sections 1101,1 through 1101.8, the current California Plumbing Code and California Green Building Standards Code,_and manufacturer's installation requirements, and that the water-odiiserviJig,plumbing fixtures comply wi a-r uireinents as indicated in the table on the following page. & n — _ Owner or Owner Agent's Upon completing and signing this return it to the Building Division in order to final your SB4072015.doe revised 08126115 ING PERMIT CANNOT BE FINALED AND,CIMPLEI'EID UNTTL THIS ATE HAS BEEN SI =Ntp ; tD IZF,'1'YtRNE:U TO THE BUILDING DIVXSI( l!+i Non -Compliant Water -Conserving Plumbing Fixture Plumbing Fixturel (Fixture Complying with Current Code Applicable to New Construction) Fixture Type Maximum Water Usage/Flow Rate 2013 CPC Ch. 4 2013 CPC Ch. 4 2013 CPC Ch. 4 Water Usage /Flow Rate 2013 CALGreen Div. 4.3 2013 CALGreen Div. 4.3 2013 CALGreen Div. 5.3 Single -Family Multi -Family Commercial Residential Residential Water Closets Exceed 1.6 Single flush toilets: 1.28 gallons/flush (Toilets) Gallons/flush Dual flush toilets: 1.28 gallons/flush effective flush volume (the composite, average flush volume of two reduced flushes and one full flush Urinals Exceed 1.0 Gallons/flush 0.5 gallons/flush Showerheads Exceed 2.5 2.0 gallons per minute @ 80 psi. Also certified to the performance criteria of gallons per minute U.S. EPA WaterSense Specification for Showerheads' (A hand-held shower is considered a showerhead.) For multiple showerheads serving one shower, the combined flow rate of all showerheads and/or other shower outlets controlled by a single valve shall not exceed 2.0 gallons per minute @ 80 psi, or the shower shall be designed to allow only one shower outlet to be in operation at a time. Faucets — Exceed 2.2 gallons Maximum 1.5 gallons per Within units: 0.5 gallons per minute @ 60 Lavatory per minute minute @ 60 psi; minimum Maximum 1.5 gallons psi Faucets 0.8 gallons per minute @ per minute @ 60 psi; 20 psi minimum 0.8 gallons per minute @ 20 psi In common and public use areas: 0.5 gallons per minute @ 60 psi 1.8 gallons per minute 60 psi Faucets — Exceed 2.2 gallons 1.8 gallons per minute @ 1.8 gallons per minute 1.8 gallons per minute @ 60 Kitchen per minute 60 psi @ 60 psi psi Faucets May temporarily increase May temporarily up to 2.2 gallons per increase up to 2.2 minute @ 60 psi, and must gallons per minute @ default to maximum 60 psi, and must 1.8 gallons per minute @ default to maximum 60 psi 1.8 gallons per minute Where faucets meeting @ 60 psi the above are unavailable, Where faucets meeting aerators or other means the above are may be used to achieve unavailable, aerators or reduction. other means may be used to achieve reduction. 1. if the existing plumbing fixture water usage/tlow rate is, equal to or lower than the figure shown, it is not required to be upgraded. SB407 2015.doe revised 08126115 UARTE0H nC .�..� uiii�in�7 �� Canadian Solar's J.1ifr u'rec modules have py i c�:�n%4�-`7� significantly raised ties;ta...da d of"module w efficiency in the sola}Fmd s" X They introduced �GE innovative four busbar eJJ e log W.61E GOP�iPLIA' demonstrates highe�o�[� utp�ut and highe�F� system reliability. Worldwi�l vwVc(3� ers h5ve embraced this next generation of modules for their excellent performance, superior reliability and enhanced value. NEW TECHNOLOGY Reduces cell series resistance Reduces stress between cell interconnectors Improves module conversion efficiency Improves product reliability ck frame luct can be ided upon request. 9�� 3 insurance -backed warranty ears non -cancelable, immediate warranty insurance �q yea Iinear power output warranty 10 product warranty on materials years; and workmanship KEY FEATURES HlghGr en,, rqy ;field MANAGEMENT SYSTEM CERTIFICATES Outstanding performance at low irradiance ISO 9001:2008 / Quality management system - Maximum energy yield at low NOCT ISO/TS 16949:2009 /The automotive industry quality management system Improved energy production through ISO 14001:2004 / Standards for environmental management system reduced cell series resistance OHSAS 18001:2007 / International standards for occupational health & safety lnc!4tased PRODUCT CERTIFICATES Long-term system reliability withIP67 IEC 61215/IEC 61730: VDE/MCS/CE /JET/SII/CEC AU/INMETRO/CQC — junction box UL 1703 / IEC 61215 performance: CEC listed (US) / FSEC (US Florida) Enhanced system reliability in extreme UL 1703: CSA / IEC 61701 ED2: VDE / IEC 62716: VDE /'IEC 60068-2.68: SGS temperature environment with special PV CYCLE (EU) / UNI 9177 Reaction to Fire: Class 1 cell level stress release technology (� B `, EVE H®AV VCYCL L `(trG VcCi t!8 CU .:USCC:;l C-r5 —=— a Positive power tolerance up to 5 W .......................................................................................................... ............ _ Stronger 40 mm robust frame to hold snow load up to 5400 Pa and CANADIAN SOLAR INC. is committed to providing high quality wind load up to 2400 Pa solar products, solar system solutions and services to customers Anti -glare project evaluation around the world. As a leading manufacturer of solar modules and Salt mist, ammonia and blowing sand PV project developerwith about 10 GW of premium quality modules resistance apply to seaside, farm and deployed around the world since 2001, Canadian Solar Inc. (NAS- desert environments DAQ: CSIQ) is one of the most bankable solar companies worldwide. CANADIAN SOLAR INC. 545 Speedvale Avenue West, Guelph, Ontario _N1 K 1 E6, Canada, www.canadiansolar.com, support@canadiansolar.com MODULE / ENGINEERING DRAWING (mm) CS6P-260P / I-V CURVES A A Roar 2!k:Vv ELECTRICAL DATA / STC* cane C1'055 sec -ion !� . i•1lDunting ;-!.^.ic R ._:ecrr ::al Data C.SiiP 26011 '2651; _ Nom_ final Max. Power (Pmax) 260 W 265 W Opt. Operating Voltage (Vmp) 30.4 V F 30.6 V LLT _ �8.66 Opt. Operating Current (Imp) 8.56 A A Open Circuit Voltage (Voc) 37.5 V _37.7 V _ v V Short_Circuit Current (Isc) 9.12 A 9.23 A Module Efficiency 16.16% 16.47% v Operating Temperature -400C -+850C _ Max. System Voltage 1000 V (IEC) or 1000 V (UL) Module Fire Performance TYPE 1 (UL 1703) or CLASS C (IEC61730) _ Max. Series Fuse Rating 15 A__ Application Classification Class A Power Tolerance 0 - + 5 W * Under Standard Test Conditions (STC) of irradiance of 1000 W/mz, spectrum AM 1.5 and cell temperature of 25°C. ELECTRICAL DATA / NOCT* Electrical Data C S6P 2 6 0 P 265P Nominal Max. Power (Pmax) 189 W 192 W Opt. Operating Voltage (Vmp)_ 27.7 V 27.9 V Opt. Operating Current (Imp) 6.80 V 6.88 A Open Circuit Voltage (Voc) 34.5 V 34.7 V Short Circuit Current (Isc) 7.39 A _ 7.48 A * Under Nominal Operating Cell Temperature (NOCT), irradiance of 800 W/mz, spectrum AM 1.5, ambient temperature 20°C, wind speed 1 m/s. PERFORMANCE AT LOW IRRADIANCE Industry leading performance at low irradiation, average +96.5% relative efficiency from an irradiance of 1000 W/m2to 200 W/m2 (AM 1.5, 25°C). The specification and key features described In this datasheet may deviate slightly and are not guaranteed. Due to on -going innovation, research and product enhancement, Canadian Solar Inc. reserves the right to make any adjustment to the information described herein at any time without notice. Please always obtain the most recent version of the datasheet which shall be duly incorporated into the binding contract made by the parties governing all transactions related to the purchase and sale of the products described herein. Caution: For professional use only. The installation and handling of PV modules requires professional skills and should only be performed by qualified professionals. Please read the safety and installation instructions before using the modules. 1 5 10 15 20 25 30 35 40 5 10 1S 20 25 30 35 40 )g 1000 W/mx 5°C IN d 800 W/W 25°C 11 600 W/W 45.c 400 W/W 65°C ' MODULE / MECHANICAL DATA Specification Data Cell Type Poly -crystalline, 6 inch Cell Arrangement 60 (6x10) Dimensions 1638x982x40 mm (64.5x38,7x1.57 in) __ Weight W 18 kg (39.7 Ibs)_ Front Cover mm tempered glass Frame Material �� _3.2 _ Anodized aluminium alloy J-Box IP67, 3 diodes Cable 4 mm2 (IEC) or 4 mm2 & 12AWG 1000 V (UL), 1000 mm (39.4 in) (650 mm (25.6 in) is optional) _ Connectors Friends PV2a (IEC), Friends PV2b (IEC / UL) _ Standard 26 pieces, 515 kg (1135.4 Ibs) Packaging _ _ (quantity & weight per pallet) Module Pieces per Container 728 pieces (40' HQ) TEMPERATURE CHARACTERISTICS $78Ci iCas_iUn Data Temperature Coefficient (Pmax) - y-0.41 % / °C Temperature Coefficient (Voc) -0.31 % / °C _ Temperature Coefficient (Isc) 0.053%/ °C Nominal Operating Cell Temperature 45±20 PARTNER SECTION ............................................................................................... ................................................................................................ Scan this QR-code to discover solar projects built with this module me ...................................................I..........I....... CANADIAN SOLAR INC. August 2015. All rights reserved, PV Module Product Datasheet V5.3_EN � o i i C P i ' Pf F J '• S. �r°tiflcatee 2284121 Master Contract: 249143 .0ject: 70048197 Date Issued: 2015-10-05 . med to: Canadian Solar Inc 545 Speedvale Aare West GuueEph, Ontario NIK R E6 CANADA Attention: Jean-Nncollas Jauubert Theproducts rod uctts listed below are eligible t® Dear the CSA Mark shmn with a aceng indicators °CC° andl 'US'for Canada and US o' with aE������ indicator I US' f orr SUS only or without either rind icatt®rr f or Canada only. 'R Issued by. `..�S pA r oA CA nd y) I V g�tm'e'n/ . Anh (Andy) Nguyen i E PRODUCTS CLASS - C531110 - POWER SUPPLIES -Photovoltaic Modules and Panels CLASS - C53119.0 - POWER SUPPLIES -Photovoltaic Modules and Panels - Certified to US Standards I Photovoltaic Modules with maximum system voltage of 600 V de or 1000 V do and Type 1 module fire performance, Model Series CS6X-XXXP, CS6X-XXXPX, where 'XXX' is the power output from 250 VV to 330 W with the following electrical ratings typical at 305 W @ Standard Test Condition (STC): j i i Open Circuit Voltage (Voc): 44.8 V Short Circuit Current (Ise): 8.97 A Operating Voltage (Vpmax): 36.3 V Current at Operating Voltage (Ipmax): 8.41 A I Photovoltaic Modules with maximum system voltage of 600 V do or 1000 V do and Type 1 module fire j performance, Model Series CS6X-XXXM, where'XXX' is the power output from 260 W to 350 W withthe following electrical ratings typical at 350 W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 46.6 V Short Circuit Current (Ise): 9.67 A Operating Voltage (Vpmax): 38.3 V Current at Operating Voltage (Ipmax): 9.14 A j jl 1 1+ 507 Rev, 2012-05-22 Pape 1 ; tCertiific,9te: 2284121 Project: 70048197 Master Contract: 249143 Date Issued: ?015-10-05 Photovoltaic Modules with maximum system voltage of 600 V do or 1000 V do and Type 1 module fire + performance, Model Series CS6P-XXXP, CS6P-XXXP-S, CS6P-XXXMX where 'XXX' is the power oaput from. 200 W to 275 W with the following electrical ratings typical at 260 W for CS6P-XXXP/ CS6P-XXXP•S. and ' CS6P-XXXMX series respectively @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 37.5 V j Short Circuit Current (Ise): 9.12 A Operating Voltage (Vpmax):. 30.4 V Current at Operating Voltage (Ipmax): 8.56 A Photovoltaic Modules with maximum system voltage of 600 V do or 1000 V do and Type 1 module fire performance, Model Series CS6P-XXXM and CS6P-XXXMX where 'XXX' is the power output from 100 W to j 290 W with the following electrical ratings typical at 290 W for CS6P-XXXM and CS6P-XXXMX sene:s respectively @ Standard Test Condition (STC): ! Open Circuit Voltage (Voc): 38.7 V Short Circuit Current (Ise): 9.59 A Operating Voltage (Vpmax): 31.9 V 9.09 A Current at Operating Voltage (Ipmax): j. Photovoltaic Modules with maximum system voltage of 600 V do and Type 1 module fire performance. I'✓todel Series CS5A-XXXM, , where 'XXX' is the power output from 170 W to 210 W with the following electrical ratings typical at 210 W @ Standard Test Condition (STC): I Open Circuit Voltage (Voc): 45.6 V Short Circuit Current (Ise): 5.90 A Operating Voltage (Vpmax): 38.1 V Current at Operating Voltage (Ipmax): 5.51 A Photovoltaic Modules with maximum system voltage of 600 V do and Type 1 module fire performance. Model j Series CS6A-XXXP, where 'XXX' is the power output from 160 W to 210 W with the following electrical ratings j typical at 210 W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 30.0 V Short Circuit Current (Ise): 9.19 A I Operating Voltage (Vpmax): 24.4 V Current at Operating Voltage (Ipmax): 8.63 A Photovoltaic Modules with maximum system voltage of 600 V do and Type 1 module fire performance. Model Series CS6F-XXXM, where'XXX' is the power output from 30W to 40W with the following electrical ratings typical at 40W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 22.8 V Short Circuit Current (Ise): 2.28 A l; Operating Voltage (Vpmax): 18.6 V j Current at Operating Voltage (Ipmax): 2.15 A i l DQD 507 Rev. 2012-05-22 cCertifnenteo 2284121 Project- 70048197 f, f Faster Contraec: 249143 Date )Issued: li)15-10-05 i Photovoltaic Modules with maximum system voltage of 600 V do and Type l module fire performance, jNfodel Series CS6F-XXXP, where'XXX' is the power output from 30W to 40W with the following electrical ratings typical at 40W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 22.6 V Short Circuit Current (Isc): 2.32 A Operating Voltage (Vpmax): 18.4 V Current at Operating Voltage (Ipmax): 2.17 A Photovoltaic Modules with maximum system voltage of 600 V do and Type 1 module fire performance. Model Series CS6H-XXXM, where 'XXX' is the power output from 20W to 26W with the following electricai watings typical at 26W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 22.7 V Short Circuit Current (Ise): 1.5 A Operating Voltage (Vpmax): 18.4 V Current at Operating Voltage (Ipmax): 1.41 A Photovoltaic Modules with maximum system voltage of 600 V do and Type 1 module fire performance, Model Series CS6H-XXXP, where 'XXX' is the power output from 20 W to 26 W with the following electrical ratings typical at.26 W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 22.5 V Short Circuit Current (Ise): 1.52 A Operating Voltage (Vpmax): 18.2 V Current at Operating Voltage (Ipmax): 1.43A Photovoltaic Modules with maximum system voltage of 600 V do and Type 1 module fire performance, Model Series CS6E-XXXM, where 'XXX' is the power output from 45 W to 60 W with the following electrical ratings typical at 60 W @ Standard Test Condition (STC): I Open Circuit Voltage (Voc): 22.8 V , Short Circuit Current (Ise): 3.42 A Operating Voltage (Vpmax): 18.6 V i Current at Operating Voltage (Ipmax): 3.23 A j 1 Photovoltaic Modules with. maximum system voltage of 600 V do and Type 1 module fire performance, Model Series CS6E-XXXP, where 'XXX' is the power output from 45 W to 60 W with the following electrical ratings typical at 60 W @ Standard Test Condition (STC): i. Open Circuit Voltage (Voc): 22.6 V ' Short Circuit Current (Ise): 3.47 A i.� Operating Voltage (Vpmax): 18.4 V I Current at Operating Voltage (Ipmax): 3.26 A DOD 507 Rev it a Page 3 J Cer-tiif Bate: 2284121 Project- 70048197 Master Cantr°act, 249143 Date Issued: S) 15-10-05 Photovoltaic Modules with maximum system voltage of 600 V do and Type 1 module fire performance, Model Series CS6D-XXXM, where 'XXX' is the power output from 60 W to 75 W with the following electriril ratings typical at 75 W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 22.5 V Short Circuit Current (Isc): 4.37 A Operating Voltage (Vpmax): 18.3 V Current at Operating Voltage (Ipmax): 4.11 A Photovoltaic Modules with maximum system voltage of 600 V do and Type 1 module fire performance, Model Series CS6D-XXXP, where 'XXX' is the power output from 60 W to 75 W with the following electrical ratings typical at 75 W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 22.3 V Short Circuit Current (Isc): 4.43 A Operating Voltage (Vpmax): 18.1 V Current at Operating Voltage (Ipmax): 4.15 A Photovoltaic Modules with maximum system voltage of 600 V do and Type 1 module fire performance. Model Series CS6C-XXXM, where 'XXX' is the power output from 120 W to 175 W with the following electocal ratings typical at 145 W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 22.4 V Short Circuit Current (Isc): 8.52 A Operating Voltage (Vpmax): 18.1 V Current at Operating Voltage (Ipmax): 8.01 A Photovoltaic Modules with maximum system voltage of 600 V do and Type 1 module fire performance. Model Series CS6C-XXXP, where'XXX' is the power output from 120 W to 165 W with the following electrical ratings typical at 150 W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 22.3 V Short Circuit Current (Isc): 8.87 A Operating Voltage (Vpmax): 18.1 V Current at Operating Voltage (Ipmax): 8.30 A Photovoltaic Modules with maximum system voltage of 600 V do or 1000 V do and Type 1 module fire performance, Model Series CS6K-XXXP, where'XXX' is the power output from 220 W to 275 W wit)t the following electrical ratings typical at 275 W for CS6K-XXXP series @ Standard Test Condition (STC.): Open Circuit Voltage (Voc): 38.0 V Short Circuit Current (Isc): 9.45 A Operating Voltage (Vpmax): 31.0 V Current at Operating Voltage (Ipmax): 8.88 A f ; I DOD 507 Rev. 2012 OS-22 l; CertiiiFlicatee 2284121 Project: 70048197 Master Contras ; 249143 Date l[ssueda 1,015-10-05 Photovoltaic Modules with maximum system voltage of 600 V do and Type 1 module fire performance. Model Series CS6A-XXXM, where'XXX' is the power output from 160 W to 230 W with the following elecu•i cal ratings typical at 205 W @ Standard Test Condition (STC): Open Circuit Voltage (Voc): 30.6 V Short Circuit Current (Ise): 9.31 A Operating Voltage (Vpmax): 24.8 V Current at Operating Voltage (Ipmax): 8.87 A Photovoltaic Modules with maximum system voltage of 600 V do or 1000 V do and Type 1 module fire performance, Model Series CS6K-XXXM, where'XXX' is the power output from 240 W to 290 W with the following electrical ratings typical at 290 W for CS6K-XXXM series @ Standard Test Condition (STC).- Open Circuit Voltage (Voc): 38.7 V Short Circuit Current (Ise): 9.59 A Operating Voltage (Vpmax): 31.9 V Current at Operating Voltage (Ipmax): 9.09 A Photovoltaic Modules with maximum system voltage of 600 V do and Type 1 module fire performance. Model Series CS6P-XXXP-SD, and CS6K-XXXP-SD where'XXX' is the power output from 240 W to 275 W with the . following electrical ratings typical at 250 W @ Standard Test Condition (STC): Output Voltage Range (Vout): 5 — 60 V Maximum Output Current (Imax): 15 A Photovoltaic Modules with maximum system voltage of 600V or 1000 V do and Type 1 module fire performance. Model Series CS6P-XXXP-TD, where'XXX' is the power output from 240 W to 275 W with the following electrical ratings typical at 250 W @ Standard Test, Condition (STC): Output Voltage Range (Vout): 16 — 32 V (Voc*) Maximum Output Current (Imax): 9.5 A *For modules with Smart Curve function the Voc is adjustable and is programmed only at the factory based on the PV module voltage. Notes: Rated electrical characteristics are within +/-10% of measured values at Standard Test Conditions of 100 mW/cmz irradiance, AM 1.5 spectrum, and cell temperature of 25°C. APPLICABLE REQUIREMENTS ULC/ORD- C1703-01 - Flat -Plate Photovoltaic Modules and Panels UL 1703-3`d Edition - Flat -Plate Photovoltaic Modules and Panels �D 507 Rev. 2012-05-22 _ 1 1 i i I Certificate- 2284121 (249143) Master Contract: 249143 The products listed, including the latest revision described below, are eligible to be marked in accordance with the referenced lCerty1cca£e. Product Certfleation History Project Date Description 4. 70048197 2015-10-05 Update Report 2284121 for 1. Seven new cell technologies 2. Two new J-box • tested with 13 different combinations of backsheets and adhesive:. New J- box and frame adhesive 4. New clamping method for ZEP frame.-, Mounting on NexTracker 6.Removal of obsolete models and materials 7. Update Fl frame for NexTracker and ATI trackers 8. Update HF10 test resuhs for Boviet Solar factory 70043990 2015-09-10 Provide Report Update to add HF test results 70031273 2015-05-01 Update test report no. 2284121 for 1. Alternate EVA - ' Changshu Tegu New Material Technology Co. Ltd.', types 72014" and "T2053 ", 0.45-0.5 mm i nominal thickness, two sheets provided (T2014 type above cell strings - superstrate side - and T2053 type below - substrate side) 2. Alternate Substrate - (Suzhou) Sunwatt Co., Ltd. ', white type "KFB-30" owrall thickness, 0.290 mm nominal. 3. Alternate Substrate - 'Crown Adbanced Material Co., Ltd. ', white type "BE-D2", overall. thickness, 0.3901nxn nominal 4. Add new Model Series CS6P-XXXP-TD , 240 W to 275 W range, ' with Tigo DC optimizer 5, Alternate Jbox - 'Changshu Friends Connector Technology Co., Ltd', junction box type CF1108-03g, rated 600 Vdc, l 1A 6. Alternate Jbox -'Changshu Friends Connector Technology Co., Ltd', junction I box type CF1108-03g b, rated 1000 V dc, 1 lA 7. Alternate Jbox -4Tigo energy Inc.#, junction box type MMJ-ES50, with Smart Curve funetlon, rated 1000 dc, 9.5A 8. Alternative Cables:. For use with MMJ-ES50 junction boxes i only, on CS6P-P-TD, NRTL approved type PV wire No. 12 AWG, rated 600 1 V minimum. Outer diameter 6.7t0.20 mm, 90°C minimum, marked sunlight j resistant 9. Add new bypass diode 30CTQ100S (For use with MMi-ES50 1 junction boxes only), rated 1 OOv, 30A 10. Alternate mounting system - CS6X-xxxPX with ZS Peak mounting system 1 I . Alternate mounting system - CS6X-xxxP with Array Technology Inc, DuraTrack# HZ Solar Tracker V3 clamps and torque tube 12. Alternate grounding method - for Brilliant Rack j Ground Mount System. 13. 70016938 2015-01-09 i Update Report 2284121 to Include Vietnam Factory "Viva Solar 3 Technology" 70015998 2014-12-24 Update Report 2284121 to add model CS6P-P-SD (w/Solaredge Optimizer), CS6P-P-TD(w/Tigo optimizer), four alternative cells and alternative 1? grounding method. I` DQD 507 Rev. 2012-05-22 i .._Page l__,1 cCertiiflcatee 2284121 Project- 70048197 70013912 2014-10-30 2761996 2014-09-24 2749251 2014-07-25 2725910 2014-05-15 2679144 2014-01-31 2676999 2013-11-13 2633572 2013-07-08 2618121 2013-04-19 2604442 2013-02-26 2600055 2013-02-06 2594501 2013-01-17 2584786 2013-01-03 2587786 2012-12-19 2559421 2012709-26 2542034 2012-07-06 2496460 2012-06-15 2515777 2012-06-12 2532459 2012-06-05 2512339 2012-03-28 2508436 2012-03-21 2490216 2012-01-13 2458713 2011-12-19 2480024 2011-12-01 QD 507 Rev. 2012-05-22 .�P Master iContraee 249143 j Date Issued: 201 -5->! 0-05 l' Update Report 2284121 to include two alternative cells and alternative grounding methods. Update Report 2284121 to add Celestica, ON as a Factory; IFE blot Required Update to include alternative cells, EVA, backsheet, potting comp and and grounding methods. Update Report 2284121 to include the addition of series -M and A4M and alternative construction. Add Factory "Canadian Solar Solutions Inc, London, ON". Update to include an alternative EVA, backsheet, junction box and cells. Update to include two alternative backsheets and two cells. Update to include an alternative EVA, backsheet, junction box, julsction box adhesive and cells.. Update to include changes to cells, alternative EVA and addition ofseries CS6K. Update to include an alternative mounting system. Update to inlcude alternative junction box and a number of poly and mono cells. Update to add factory "CSI Central Power". Update to include changes to cells, alternative j-box and bacI< sheeis BEC- 301 by Hangzhou First and VTPEIRW by Taiflex. 1 Update to include the addition of Flexcon KPE backsheet. Update to include new half cell modules series PT, addition o#' 1000 V rating, alternative j-boxes and adhesive. Evaluation to add backsheet from COVEME for all the module series (with F806 EVA, CM0804 junction box and Tonsan 1527 adhesive), Update to include the evaluation of factory location in South Korea ( includes HF10 test sequence). Update to include new models (smaller modules), alternative cells and backsheets. Update to include alternative cells. Update to include three alternative cells and an alternative Toyo back sheet, Update to add CS5P-xxxP and CS5A-XXXP Series. Evaluation for an alternative (Shunfeng) cell and j-box with Isovolta AAA backsheet with PV744 adhesive. Evaluation for alternative JA Solar cells and to add new series. Pa epe 2 i i Cerfficateo 2284121 I Project: i i 70048197 2470474 2011-10-28 2455625 2011-09-02 2441645 2011-07-26 2431019 2011-06-03 2404638 2390337 2380821 2284122 2284121 2011-04-18 2011-02-08 2010-12-17 2010-10-14 2010-06-3 0 Master Contraer 249143 Date Issued. 2015-10-05 Update to add the laminates (without frame). Update to add smaller modules with cut cells. Update to include change in glass dimensions, black backsheet, nwv frame. and new j-box and edgeseal adhesive. Update to include the addition of model series CS6A and use of aliernative mateirals and components. Update to include an alternate lamination line, includes HFI0 tezequence. Addition of factory location in Ontario. Update to include Model Series CSSA-XXXM and CSST-XXXI\,i. Addition of 72 cell series CS6X-XXXP and CS6X-XXXM. Evaluation of PV Panel Series for C/CSA/US Mark. I { DQD 507 Rev. 2012-05 22 j solar -••= SolarEdge Single Phase Inverters For North America SE3OOOA-US / SE3800A-US / SE5O0OA-US / SE6OOOA-US / SE760OA-US / SE10OOOA-US / SE1140OA-US ':'o a antY �e)JODV.r�' d II I P The best choice for SolarEdge enabled systems Integrated arc fault protection (Type 1) for NEC 2011690.11 compliance Superior efficiency (98%) Small, lightweight and easy to install on provided bracket Built-in module -level monitoring Internet connection through Ethernet or Wireless Outdoor and indoor installation Fixed voltage inverter, DC/AC conversion only Pre -assembled Safety Switch for faster installation Optional — revenue grade data, ANSI C12.1 USA- GERMANY - ITALY - FRANCE -JAPAN -CHINA - AUSTRALIA -THE NETHERLANDS - ISRAEL www.solaredge.us olar=@oSingle Phase Inverters for North America SE3000A-US / SE380OA-US / SE5000A-US / SE6000A-US / SE760OA-US / SE10000A-US / SE1140OA-US SE3000A-US ISE380OA-US SE5000A-US SE6000A-US SE760OA-US I SE10000A-US I SE11400A-US OUTPUT - Nominal AC Power Output 3000 3800 5000 6000 7600 9980 @ 208V 11400 VA ........................................ ............... .............. ................ ................ ................ ...10000[?,240V................. ................ Max. AC Power Output 3300 I 4150 5400 @ 208V. ( 6000 I 8350 10800 @ 208V 12000 I VA ....................................... . 5450 @24DV .. ................10950 n�240V. . AC Output Voltage Min.-Nom. Max.(I) 183 208 229 Vac .....-208 ............................. ................ .. .... . ✓ .......�............... 1....................... /........I.. ..............1.......... AC Output Voltage Min.-Nom.-Max!ii ( I ( ✓ 211 - 240 - 264 Vac ........................................ AC Frequency Min. Nom: Max!'i ............. ......... ( ............. . . ................ ............................................... 59.3 60 :605 (with HI country setting 57 - 60 - ................. 60.5) ............... I Hz . .. Max Continuous Output Current ( I 12S ( 16 i Z4 @� 208V ( 25 I 32 I 47 5 A .........i........... ........... 42, ( 240V„ ........... . . ..... GFDI Threshold ........................................ ............... .............. ................................................................. ................. I. 4 ......... Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes I Yes INPUT Maximum DCPower(STC) .................. 4050 ............. 5100 .............. 6750 8100 10250 ................................................ ..13500 ... ..... 15350 W Transformer.less, Ungrounded ...................... I ....... ............... .............. ............. Yes Max:lnput Voltage I 500................ ................. ................. I... Vdc... ............................. Nom. DC Input Volta e . .............. . ...................... .... 325 @ 208V / 350 @ 240V . . .. ..... ....... Vdc Max. Input Curren ( 9.5 I.15;5 33 @20� V.. I �. Adc... .. ....................................... ......... ...........13...... @ 240V .I ...... 18.......I...... 23.......) ..30 5 ................. Max. Input Short Circuit Current I .............. ............... - 45 ..................................... I Adc Reverse Polarity Protection........... ........... ..... .... I........... Yes ................ Ground -Fault Isolation Detection ........................................ ( .... .. .. 600k-Q Sensitivity .... ........ .. ............... . ........ Maximum Inverter Efficiency.......... I.....97;7. I.....98.2 I......98.3 I..... 98;3 I.......98 .. I.......98.......I.......98.......I.... YC .... .................. CEC Weighted Efficiency ..... ( 97.5 .............. 98...... ................ .................... 208V 998 I 97.5 ( 97.5 91 @ 208V 97.5 1. �? 2 OV .... 7. 97;5,� 240V.. ................. ......... Nighttime Power Consumption L <2.5 I <4 I W ADDITIONAL FEATURES Supported Communication Interfaces ........................................ . . . .. .. . .. .. . . .............. RS485, RS232, Ethernet, ZigBee (optional) ........... ................ ................... ................... ................ ....... Revenue Grade Data, ANSI C12.1 O tional(3l Rapid Shutdown — NEC 2014 690.12 I Functionality enabled when SolarEdge rapid shutdown kit is install ed(4j I STANDARD COMPLIANCE Safety ........................................ ........ ....... ....... UL1741, UL16996, UL1998 , CSA 22.2 ................ ............................... .................. .......... ..... .......... Grid Connection Standards I IEEE1547 1 I Emissions FCC part15 class B INSTALLATION SPECIFICATIONS AC output conduit size / AWG range p 3/4" minimum / 16-6 AWG ..... ............................... 3/4" minimum / 8-3 AWG ........... ..... ......... ....... .............................. DC input conduit size / # of strings / ........... . . 3/4 minimum / 1-2 strings / AWG ran e � 3/4' minimum / 1-2 strings / 16-6 AWG I. 14-6 AWG .... .................I........ Dimensions with Safety Switch 30.5 x 12.5 x 7.2 775x315x184 / I 30.5 x 12.5 x 10.5 / I in / (FIXWXD) 775 x 315 x 260 . ........... .. ........... ..... .MM... .............................. Weight with Safety Switch ............ .... .......... ( ..........51. .... . . . ..... ..... ... ... . 2 / 23.2 ......... I ................ . 54.7 / 24.7 ................ .... I 88 41 40.1 ................. I lb kg Natural convection Cooling Natural Convection and internal Fans (user replaceable) fan (user ................................ ..... ..... .............. .................................replaceable).. ............... .. ................ � 25 ............................. ................ .< 50 dBANoise ........................................ Min.-Max. Operating Temperature I (') -13 to +140 / -25 to +60 (-40 to +60 version available(')) I °F / °C Ran e .r,g.................................. ........ Protection Rating ...........0............................ I ........... NEMA 3R .. .............. ................................................................. ................. .......... lrl For other regional settings please contact SolarEdge support. al A higher current source may be used; the inverter will limit its input current to the values stated. Inl Revenue grade inverter P/N: SExxxxA-US000NNR2 (for 760OW inverter:sE7600A-US002NNR2). Rapid shutdown kit P/N: SE1000-110-51. Isl -40 version P/N: SExxxxA-USOOONNU4 (for 760OW inverter:SE760OA-US002NNU4). solar- •• MW - SolarEdge Power Optimizer Module Add -On For North America PV power optimization at the module -level- Up -to 25% more energy Superior efficiency (99:576) , Mitigates all types of module mismatch losses; from manufacturing tolerance to partial shading Flexible system,design for maximum space utilization -Fast installation with a single bolt Next generation-maintenancewith module -level monitoring_ Module -level voltage shutdown.for installer and firefighter safety USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA www.solaredge.us solar=ee SolarEdge Power Optimizer Module Add -On for North America P300 / P320 / P400 / P405 P300 P320 P400 P405 (for 60-cell modules) (for high -power (for 72 & 96-cell (for thin film 60-cell modules) modules) modules) INPUT Rated Input DC Powerlli .......... ................ 300......................320.......................400......................405 ............... W..... Absolute Maximum Input Voltage 48 I 80 125 I Vdc (Voc at lowest temperature).. ................._...........................I......................... ....................... ............ MPPT Operating Range I . ................ 8_. 48 8 - 80 12.5 - 105 I ........................... Vdc . Maximum Short Circuit Current (Isc) ...................... . .. . ................................. I 10 I. 11 I 10 ...... ....... Adc ...................................... . Maximum DC .. ut Current .................... 12.5 13.75 12S Adc Maximum Efficiency 99:5.................................................... ....°...... Weighted Efficiency....................I ° Overvoitage Category I II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 .......................... Adc .... ..... .............. Maximum Output Voltage ................................................................................. 60 I 85 I Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power STANDARD COMPLIANCE Vdc EMC I ; FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 ...........................Yes.................................................... ........................................... Safety I ........................................ ....................... IEC62109.1(class II safety): UL1741 ....................... ... RoHS INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage ............................................................................................................................................................ 1000 Vdc Compatible inverters ......................... I All SolarEdpe Single Phase and Three Phase inverters ................................................. ............ Dimensions (W x L x H) � 128x152x275/ 128x152x35/ I.....5 128x152x48/ mm / in I 5 x 5.97 x 1.08 x 5.97 x 1.37 ..........5 x 5.97 x 1.89 .......................... Weight (including cables) .................. I ............................ 770 / 1.7 .................... I. ....... 930 / 2.05........�....... 930 / 2 :05..... _..I ... gr / Ib Input Connector ..... ............................. ............................ MC4 Compatible .................. ............. _............. ............................ . Output Wire Type /Connector I ................................................. Double Insulated; MC4 Compatible .. I ... . Output Wire Length .... ......... I ...... 0.95 J.3.0 I 1 2 / 3.9...................... ......................._......._..._........ ... ... I m ft .. . ... Operating Temperature Range .......... 40 +85 / 40 +185 ....................................................................... °C / °F Protection Rating .......... ( . IP68 / NEMA6P ............................................................................. ........... Relative Humidity 0 : 100 pI Rated STC power of the module. Module of up to +5% power tolerance allowed. PV SYSTEM DESIGN USING A SOLAREDGE INVERTER(2) SINGLE PHASE THREE PHASE 208V THREE PHASE 480V Minimum String Length 8 10 18 (Power Optimizers)......................................................... . .. . . Maximum String Length ( (PoweOptimizers.................. ..... .................. ................5.0 .0.. ............. .W............ Maximurn Powe ............. . gy........... 5250 6000 127.5.............. ...............25...............I ...............25............... I......... Parallel Strings of Different Lengths or Orientations ................................................................................................. e5..................................................... IZI It is not allowed to mix P405 with P300/1'400/13600/13700 in one string. SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE # DESCRIPTION • SYSTEM SIZE: 6095W DC, 5000W AC • ALL WORK SHALL COMPLY WITH 2O13 CEC, 2013 CBC, 2013 CRC MUNICIPAL SE SERVICE ENTRANCE SOLAR MODULES PV-1.0 COVER SHEET • MODULES: (23) CANADIAN SOLAR: CS6P-265P CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION RAIL PV-2.0 SITE PLAN • INVERTER(S): INSTRUCTIONS. (1) SOLAREDGE TECHNOLOGIES: SE5000 (240V) W/ -ER-US • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2O13 CEC. F81 MAIN PANEL PV-3.0 LAYOUT OR A -US • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH 2O13 CI=C. PV-4.0 ELECTRICAL • RACKING: SNAPNRACK SERIES 100 UL; FLASHED L FOOT. • PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS .ARE SOLIDLY SEE PEN D01. GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35. M SUB-PANEL STANDOFFS & PV-5.0 SIGNAGE • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. FOOTINGS INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. F01 PV LOAD CENTER CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(E) AND 2012 CHIMNEY • IF 605.11.2. • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. SM SUNRUN METER ATTIC VENT • 9.23 AMPS MODULE SHORT CIRCUIT CURRENT. • 14.42 AMPS DERATED SHORT CIRCUIT CURRENT (690.8 (a) & 690.8 (b)). [ FLUSH ATTIC VENT CE1IVED PM DEDICATED PV METER PVC PIPE VENT INVERTER(S) WITH INV INTEGRATED DC METAL PIPE VENT DISCONNECT AND AFCI T-VENT BY r AC NO AC DISCONNECT(S) SATELLITE DiSN ``''� Building Depatnent h f t`a 0 2016 IIEN DC DISCONNECT(S) FA FIRE SETBXzi _j CB FVIEWr u i- R CODE COMPLIANCE~ COMBINER BOX HARDSCAPE (— —1 INTERIOR EQUIPMENT — PL— PROPERTY LINE sunrunLE ] � SHOWN AS DASHED SCALE: NTS A AMPERE AC ALTERNATING CURRENT T DEPARTMENT GILBERT CORREIA, C10, C46 AFCI ARC FAULT CIRCUIT INTERRUPTER JPERTINO CA CL #750184 AZIM AZIMUTH A �y iOVED VICINITYMAP COMP COMPOSITION �s and„ 2300 ZANIER ROAD, UNIT F, SAN JOSE, CA 95131 DC DIRECT CURRENT �Pecifications MUST be ke• PHONE 48949294062 ? (E) EXISTING ^O;;structiCij. It is unlawful to Oru;teratierls on same, or to d: EXT EXTERIOR 0ri1, w0outa CUSTOMER RESIDENCE: FIRM FRAMING PPrcval from the Building C WILLIAM D ERDMAN INT INTERIOR ,is plan and specifications SHAD 10808 JUNIPER CT, LBW LOAD BEARING WALL or to be an approval of the vlo, CUPERTINO, CA, 95014 MAG MAGNETIC pt:.., MSP MAIN SERVICE PANEL _ CitY Ordinance or State ! TEL. (650) 964-3966 APN #: 342577007 (N) NEW �^/ �— NTS NOT TO SCALE PROJECT NUMBER: OC ON CENTER 102R-808ERDM P�T PLANS CHE KED BY PRE-FAB PRE -FABRICATED G b PSF POUNDS PER SQUARE FOOT DESIGNER: /J M PV PHOTOVOLTAIC MICHAELA FLEMING 4 _ p 0 L✓ 949 705 3956 10808 Juniper Ct DATE 3 TL TRANSFQ,WE S PLANNING DEPT TYP TYPICALI,m DRAFTER: V VOLTS CE COP RBIEL2 CUPERTINO W WATTS SHEET 0 ,ePao- rA NAME DATE COMMENTS COVER SHEET � a REV: A 3/22/2016 PAGE PV-1.0 SITE PLAN - SCALE = 1/16" = 1'-0" T LNI (E) (N) ARRAY (N) ARRAY AR - Qv e�- FIRE SETBACKS (3' TYP) TRUE MAG PV AREA PITCH AZIM AZIM (SQFT) AR-01 26' 149' 135' 102 AR-02 26' 239' 225' 119 AR-03 26' 149' 135' 170 SITE PLAN - SCALE = 1/64" = 1'-0" 16'-4" 108'-6" Z.`-�-,UPERTINO A Q� r3li0ding Departnvnt "CIDE Co MPLIANCL By sunrun GILBERT CORREIA, C10, C46 CA CL #750184 2300 ZANKER ROAD, UNIT F, SAN JOSE, CA 95131 PHONE 408.746.3062 FAX 408. 894.9294 CUSTOMER RESIDENCE: WILLIAM D ERDMAN 10808 JUNIPER CT, CUPERTINO, CA, 95014 TEL, (650) 964-3966 APN #: 342577007 PROJECT NUMBER 102R-808ERDM DESIGNER: MICHAELA FLEMING 949,705. 3956 DRAFTER: RBIEL2 SHEET SITE PLAN REV: A 3/22/2016 PAGE PV-2.0 . I ROOF TYPE AR-01 COMP SHINGLE AR-02 COMP SHINGLE AR-03 COMP SHINGLE D1 - AR-01 - SCALE: 1/8" = 1' - 0" PITCH: 26° AZIM:149° (9 11 ATTACHMENT FLASHED L FOOT. SEE PEN D01 FLASHED L FOOT. SEE PEN D01 FLASHED L FOOT. SEE PEN D01 r 2'-6" ROOF HEIGHT ROOF FRAME FRAME TYPE EXPOSURE MATERIAL SINGLE STORY ATTIC WOOD RAFTER SINGLE STORY ATTIC WOOD RAFTER SINGLE STORY ATTIC WOOD RAFTER D2 - AR-02 - SCALE: 1/8" = 1'-0" PITCH: 26° AZIM:239° 0 2 X 8 RAFTER 24" FRAME MAX FRAME OC ROOF EDGE MAX RAIL SIZE SPAN SPACING ZONE SPAN 2 X 8 12'-6" 24" 3'-0" 6'-0" 2 X 8 12'-6" 24" 3'-0" 6'-0" 2 X 8 12'-6" 24" 3'-0" 6'-0" ROOF FRAMING DETAIL - SCALE: NTS RIDGE BOARD 5/16" X 3.5" LAG SCREW. 1 BOLT PER PENETRATION COMP SHINGLE ROOF SOLAR MODULE TOP PLATE 2X8 RAFTERS, 24" O.C. LOAD BEARING WALL MAX RAIL DESIGN CRITERIA OVERHANG MODULES: 2' - 0" CANADIAN SOLAR: CS6P-265P MODULE DIMS: 2, 0" 64.5" x 38.7" x 1.57" 2' - 0" MODULE CLAMPS: Portrait: 13.39" - 16.14" Landscape: 7.87" - 9.84" MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 0 PSF 110 MPH 3-SEC GUST. LAG SCREWS: 5/16"x3.5": 2.5" MIN EMBEDMENT INSTALLERS TO VERIFY RAFTER SIZE, SPACING AND SLOPED SPANS, AND NOTIFY E.O.R. OF ANY DISCREPANCIES BEFORE PROCEEDING. CUPERTINO Building Department V1EVVIL OR CEDE COMPLIANCE ke d By �.J`y lyAlrlrw sunrun GILBERT CORREIA, C10, C46 CA CL #750184 2300 ZANKER ROAD, UNIT F, SAN JOSE, CA 95131 PHONE 408.746.3062 FAX 408.894.9294 CUSTOMER RESIDENCE: WILLIAM D ERDMAN 10808 JUNIPER CT, CUPERTINO, CA, 95014 TEL. (650) 964-3966 APN #: 342577007 PROJECT NUMBER 102R-808ERDM DESIGNER: MICHAELA FLEMING <,aq DRAFTER: RBIEL2 SHEET LAYOUT REV: A 3/22/2016 PAGE PV-3.0 120/240 VAC SINGLE PHASE SERVICE METER4: OPG&E 1006139874 UTILITY GRID HOT BUSS EXISTING 200A MAIN (N) LOCKABLE —• PANEL BLADE TYPE (N) SUN RUN FACILITY AC DISCONNECT METER LOADS 3 l 3 l-3 AGILITY 30A PV - GROUND SQUARE D 250V METER BREAKER AT DU221 RB SOCKET OPPOSITE END 3R, 30A,2P 125A CONTINUOUS OF BUSBAR 120/240VAC & 240V METER 200A, FORM 2S SOLAREDGE TECHNOLOGIES: SE5000 (240V) W/ -ER-US OR A -US 5000 WATT INVERTER LOAD RATED DC DISCONNECT & AFCI 2 JUNCTION BOX 1 PV MODULES OR EQUIVALENT CANADIAN SOLAR: CS6P-265P /f (23) MODULES OPTIMIZERS WIRED IN (1) SERIES OF (13) mot' OPTIMIZERS AND (1) SERIES OF (10) LL OPTIMIZERS SOLAREDGE POWER OPTIMIZER P300 CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4) 10 AWG PV WIRE NONE (1) 10 AWG BARE COPPER 2 3/4" EMT OR EQUIV. (4) 10 AWG THHN/THWN-2 NONE (1) 8 AWG THHN/THWN-2 3 3/4" EMT OR EQUIV. (2) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 MODULE CHARACTERISTICS CANADIAN SOLAR: 265 W CS6P-265P OPEN CIRCUIT VOLTAGE 37.7 V MAX POWER VOLTAGE 30.6 V SHORT CIRCUIT CURRENT 9.23 A OPTIMIZER CHARACTERISTICS MIN INPUT VOLTAGE 8 VDC MAX INPUT VOLTAGE 48 VDC MAX INPUT ISC 10 ADC MAX OUTPUT CURRENT 15 ADC SYSTEM CHARACTERISTICS - INVERTER 1 SYSTEM SIZE 6095 W SYSTEM OPEN CIRCUIT VOLTAGE 13 V SYSTEM OPERATING VOLTAGE 350 V MAX ALLOWABLE DC VOLTAGE 500 V SYSTEM OPERATING CURRENT 17.4 A SYSTEM SHORT CIRCUIT CURRENT 30 A NOTES TO INSTALLER: 1. 13 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE. 2. ADD 30 AMP PV BREAKER TO MAIN PANEL. TINO �`•�,'>;:r t-iUiIG'In] Dc'',�oc^ft'if3i1t AF 3 D 2016 EVIBV�/E=C r JK r.::;'JB COMPLIANCE Kevl--eyed By 6-12 AWG BARE 5/16"-18 SS BOLT COPPER WIRE SS SPLIT LOCK WASHER (TORQUE TO 16 FT-LBS) SNAPNRACK \ GROUND LUG Fl BONDING \ CHANNEL NUT SS BONDING RAIL PINS NOTE: • ALL HARDWARE IS INCLUDED FROM MANUFACTURER • A MINIMUM OF ONE GROUND LUG IS TO BE INSTALLED ON EVERY CONTINUOUS ROW OF MODULES • GROUNDING LUG MAY BE INSTALLED IN EITHER RAIL CHANNEL • GROUNDING LUG MAY BE INSTALLED SO GROUND WIRE IS PARALLEL OR PERPENDICULAR TO RAIL • ENSURE SPLIT LOCK WASHER IS INSTALLED ON TOP OF COPPER WIRE SNAPNRACK GROUNDING SCALE: NTS PER CODE: 690.52 LABEL LOCATION: DC DISCONNECT, INVERTER (PER CODE: CEC 690.35(F)) [To be used when inverter is ungrounded] AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: CEC 690.17(E)) LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION PER CODE: CEC 690.17(E), CB LABEL LOCATION: INVERTER, JUNCTION BOXES (ROOF), AC DISCONNECT (PER CODE: CEC690.13.G.3 & CEC 690.13.G.4) LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: CEC690.54) LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: CEC 705.12(D)(7)) [Not required if panelboard is rated not less than sum of ampere ratings of all overcurrent devices supplying it] IL i OR V EZ LABEL NNO MARKINGOS PLACED ON ALL INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES, CATION:��`f Tina ���iE'('f j�nt AND CABLE ASSEMBLIES AT LEAST EVERY 10 FT, AT TURNS AND ABOVE/BELOW PENETRATIONS AND ALL COMBINER/JUCTION BOXES. (PER CODE: IFC605.11.1.4) Vs LABEL LOCATION: DISCONNECT, POINT OF INTERCONNECTION (PER CODE: CEC690.13(B)) LABEL LOCATION: WEATHER RESISTANT MATERIAL, DURABLE ADHESIVE, UL969 AS STANDARD TO WEATHER RATING (UL LISTING OF MARKINGS NOT REQUIRED), MIN %" LETTER HEIGHT ARIAL OR SIMILAR FONT NON -BOLD, PLACED WITHIN THE MAIN SERVICE DISCONNECT, PLACED ON THE OUTSIDE OF THE COVER WHEN DISCONNECT IS OPERABLE WITH SERVICE PANEL CLOSED. (PER CODE: CEC690.15, 690.13(B)) 1 ADC1 I n! ATInkl POINT OF INTERCONNECTION (PER CODE: CEC 705.12(D)(4)) CONDUIT, COMBINER BOX (PER CODE: CEC690.31(G)(3)(4) & CEC 690.13(G)(4) LABEL LOCATION: DC DISCONNECT, INVERTER (PER CODE: CEC690.53) ADHESIVE FASTENED SIGNS: • THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. • WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS, AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4 [NEC 110.21(B) FIELD MARKING). . ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.1.31 ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN SOLAR PANELS ON ROOF 7 SERVICE ENTRANCE AND PV BREAKER DISCONNECT INVERTER LOCATION SUNRUN METER AC DISCONNECT 10808 JUNIPER CT, CUPERTINO, CA, 95014 MPLIAINCE SMOKE / CARBON MONOXIDE ALARMS OWNER CERTIFICATE OF COMPLIANCE M FILE CUPERTINO 'CA ddr-ess----� PERMIT t PURPOSE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building(Wcupertino.ong m This affidavit is a self -certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R314, 2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single-family and multi -family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds $1000.00, CRC Section R314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations: AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of the bedroom(s) X X On every level of a dwelling unit including basements X X Within each sleeping room X Carbon Monoxide alarms are not required in dwellings which do not contain fuel -burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. Power Supply: In dwelling units with no commercial power supply, alarm(s) may be solely battery operated. h-i existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl space. Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2. An electrical permit is required for alarms which must be connected to the building wiring. As owner of the above -referenced property, I hereby certify that the alarm(s) referenced above has/have been installed in accordance with the manufacturer's instructions and in compliance with the California Building and California Residential Codes. The alarms have been tested and are operational, as of the date signed below. I have read and agree to comply with the terms and conditions of this statement _Owner ol-OwnerAgent's) Name: `-` .._ ma V\Si nafur ........ ....... ... .. .. ......... ................... ....���.. . -Coontractor_Nam:e: € rSi nature ��':........ .............................................. c ..... ......4. ........... Smoke and COforni.doc revised 03118114 +CUPERTINO Owner N WATER -CONSERVING PLUMBING FIXTURES F'4� OWNER CERTIFICATE OF COMPLIANCE E, COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISION 10300 TORRE AVENUE CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building(a)cupertino.org Address n C Cii/_ _MEW 1� 1. Is your real property a registered historical site? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. No Go to Question 2. 2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its plumbing, installation of water -conserving plumbing fixtures is not technically feasible? Yes Civil Code Sections 1101.1 through 1101.8 do not apply. ❑ The licensed plumber's certification has been provided to the Building Division'. Skip the rest of the form and sign bottom of form. f 6 No Go to Question 3. 3. Is water service permanently disconnected for your building? El Yes Civil Code Sections 1101.1 through 1101.8 do not apply, Skip the rest of the form and sign bottom of form. N No Go to Question 4. Li 4. Is your real property built and available for use or occupancy on or before January 1,_ 1994? ❑ No My real property is built and available for use or occupancy after January 1, 1994. Civil Code Sections 1101.1 through 1101.8do not apply. Skip the rest of the form and sign bottom of form. Yes My real property is built and available for use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101.8 apply. Check one of the three following statements and sign bottom of form.. 5. Please check ONE of the following: 14 My property is a single-family residential real property. See Civil Code Section 1101.4. t� On and after January 1, 2014, building alterations or improvements shall require all non -compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non- compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements)., My property is a multifamily residential real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019"`all non -compliant plumbing fixtures shall be replaced with water - conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). ❑ My property is a commercial real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non -compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). I, as the owner or owner's agent of this property, certify under penalty of perjury that non -compliant plumbing fixtures will be replaced prior to date specified above with water -conserving plumbing fixtures in accordance with Civil Code Sections 1101.1 through 1101.8, the current California Plumbing Code and California Green Building Standards Code, .arid manufacturer's installation requirements, and that the water-AnserviAg plumbing fixtures comply wi ' aunts as indicated in the table on the following pace. ,, 1 //n _ _ I Owner or Owner Agent's. Signature{ J j/ 1 ° �(' Date: I Upon completing and signing this Certte, p ease return it to the Building Division in order to final your building `permit. SB4072015.doc revised 08126115 Non -Compliant Water -Conserving Plumbing Fixture Plumbing Fixturel (Fixture Complying with Current Code Applicable to New Construction) Fixture Type Maximum Water Usage/Flow Rate 2013 CPC Ch. 4 2013 CPC Ch. 4 2013 CPC Ch.4 Water Usage /Flow Rate 2013 CALGreen Div. 4.3 2013 CALGreen Div. 4.3 2013 CALGreen Div. 5.3 Single -Family Multi -Family Commercial Residential Residential Water Closets 'Exceed 1.6 Single flush toilets: 1.28 gallons/flush (Toilets) Gallons/flush Dual flush toilets: 1.28 gallons/flush effective flush volume (the composite, average flush volume of two reduced flushes and one full flush Urinals Exceed 1.0 Gallons/flush 0.5 gallons/flush Showerheads Exceed 2.5 2.0 gallons per minute @ 80 psi. Also certified to the performance criteria of gallons per minute U.S. EPA WaterSense Specification for Showerheads (A hand-held shower is considered a showerhead.) For multiple showerheads serving one shower, the combined flow rate of all showerheads and/or other shower outlets controlled by a single valve shall not exceed 2.0 gallons per minute @ 80 psi, or the shower shall be designed to allow only one shower outlet to be in operation at a time. Faucets — Exceed 2.2 gallons Maximum 1.5 gallons per Within units: 0.5 gallons per minute @ 60 Lavatory per minute minute @ 60 psi; mininium Maximum 1.5 gallons psi Faucets 0.8 gallons per minute @ per minute @ 60 psi; 20 psi minimum 0.8 gallons per minute @ 20 psi In common and public use areas: 05 gallons per minute @ 60 psi 1.8 gallons per minute 60 si Faucets — Exceed 2.2 gallons 1.8 gallons per minute @ 1.8 gallons per minute 1.8 gallons per minute @ 60 Kitchen per minute 60 psi @ 60 psi : psi Faucets May temporarily increase May temporarily up to 2.2 gallons per increaseup to 2.2 minute @ 60 psi, and must gallons per minute @ default to maximum 60 psi, and must 1.8 gallons per minute @ default to maximum 60 psi 1.8 gallons per minute Where faucets meeting @ 60 psi the above are unavailable, Where faucets meeting aerators or other means the above are may be used to achieve unavailable, aerators or reduction. other means may be used to achieve reduction. 1. u uic cxisung pcumoing nxture water usageirtow rate is equal to or lower than the figure shown, it is not required to be upgraded. SB40 7 2015. doe revised 08126115