Loading...
B-2016-1725CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO:B-2016-1725 20087 LAS ONDAS CT CUPERTINO, CA 95014-3106 (369 30 031) SANTA CRUZ WESTSIDE ELECTRIC INC SANTA CRUZ, CA 95060 OWNER'S NAME: PATEL RAKESH HASMT.JKIhN AND ANGIRA R TRUSTEE DATE ISSUED: 04/08/2016 OWNER'S PHONE: 408-366-2624 _ PHONE NO: (831) 469-8888 LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO: License Class C-10 Lic. #846294 Contractor SANTA CRUZ WESTSIDE ELECTRIC INC Date 04/30/2017 X BLDG —ELECT —PLUMB I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing MECH X RESIDENTIAL COMMERCIAL with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. JOB DESCRIPTION: INSTALL (N) PV SOLAR ARRAY SYSTEM FLUSH -MOUNTED I hereby affirm under penalty of perjury one of the following two declarations: DIRECTLY TO THE ROOF - 18 MODULES, 4.009 KW 1. I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by 1 A /� Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Sq. Ft Floor Area: Valuation: $16065.00 APPLICANT CERTIFICATION I certify that I have read this application and state that the above APN information is correct. I agree to comply with all city and county ordinances Number: Occupancy Type: 36930 031 and state laws relating to building construction, and hereby authorize 69 representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which PERMIT EXPIRES IF WORK IS NOT STARTED may accrue against said City in consequence of the granting of this permit. WITHIN 180 DAYS OF PERMIT ISSUANCE OR Additionally, the applicant understands and will comply with all non -point source regulations per the Cuperyno Municipal Code, Section 9.18. 180 DAYS FROM LAST1 CALLED-1 SPECTION. Sign re Date 4/8/2016 Issued by: Alex Vallelunea r Date:04/08/2016 OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of the RE -ROOFS: following two reasons: All roofs shall be inspected prior to any roofing material being installed. If a roof is r. I, as owner of the property, or my employees with wages as their sole installed without first obtaining an inspection, I agree to remove all new materials for compensation, will d6 the work, and the structure is not intended or offered for inspection. sale (Sec.7044, Business & Professions Code) 2. I, as owner of the property, am exclusively contracting with licensed Signature of Applicant: contractors to construct the project (Sec.7044, Business & Professions Code). Date: 4/8/2016 I hereby affirm under penalty of perjury one of the following three declarations: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER 1. I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. HAZARDOUS MATERIALS DISCLOSURE 2. I have and will maintain Worker's Compensation Insurance, as provided for by I have read the hazardous materials requirements under Chapter 6.95 of the Section 3700 of the Labor Code, for the performance of the work for which this California Health & Safety Code, Sections 25505, 25533, and 25534. 1 will permit is issued. maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the 3. I certify that in the performance of the work for which this permit is issued, I Health & Safety Code, Section 25532(a) should I store or handle hazardous shall not employ any person in any manner so as to become subject to the material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I Worker's Compensation laws of California. If, after making this certificate of will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and exemption, I become subject to the Worker's Compensation provisions of the the Health & Safety Code, Sections 25505 5533, nd 25534. Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. Owner or_autho .iced agent: APPLICANT CERTIFICATION Fate: 4 2016� I certify that I have read this application and state that the above information is CONSTRUCTION LENDING AGENCY correct. I agree to comply with all city and county ordinances and state laws I hereby affirm that there is a construction lending agency for the performance relating to building construction, and hereby authorize representatives of this city of work's for which this permit is issued (Sec. 3097, Civ C.) to enter upon the above mentioned property for inspection purposes. (We) agree Lender's Name to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in Lender's Address consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal ARCHITECT'S DECLARATION Code, Section 9.18. 1 understand my plans shall be used as public records. Licensed Signature Date 4/8/2016 CUPERTINO ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 AE (408) 777-3228 . FAX (408) 777-3333 - building ED-cupertino.orq PROJECT ADDRESS 20087 LAS ON DAS CT. APN # 369- -q () _ 03 OWNER NAME RAKESH HASMUKH PATEL PHONE 408 366-2624 E-MAIL , STREET ADDRESS 20087 Las Ondas Court CITY, STATE, ZIP Cu er6no 95014 FAX CONTACT NAME Kristi Cassetta PHONE831-226-9363 E-MAIL kcassetta@sandbarsc.com STREET ADDRESS 2119 Delaware Avenue CITY, STATE, ZIP Santa Cruz Ca 95060 FAX 831-515-5098 ❑ OWNER ❑ OWNER -BUILDER ❑ OWNER AGENT CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME LICENSE NUMBER LICENSE TYPE BUS. LIC # Sandbar 846294 C-10 �mnpGy i z Westside Electric dba Sandbar E- kcassetta(@,sandbarsc.com IL FAX 831-515-5098 STREET ADDRESS 2119 Delaware Avenue CITY, STATE, ZIP Santa Cruz Ca 95060 PHONE 831-469-8888 ARCHITECT/ENGINEER NAME Sun evit LICENSE NUMBER BUS. LIC # %1 07 �,� COMPANY NAME E-MAIL Sam - sholing@sungevity.com FAX STREET ADDRESS 66 Franklin Street Ste. 310 CITY, STATE, ZIP Oakland CA 94607 PHONE USE OF Xl SFD or Duplex ❑ Multi -Family PROJECT IN WILDLAND PROJECT IN STRUCTURE: ❑ Commercial URBAN INTERFACE AREA ❑ Yes No FLOOD ZONE ❑ Yes ❑ No IX SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PANELS: NUMBER OF PANELS/UNITS: KILOWATTS (COM RCLAL O Y): TOTAL VALUATION: $16,065 $ U L!! DESCRIPTION OF WORK Installation of a 4.59kw gdd tied photovoltaic solar arra roof mount Zj F1 RECENED BY: } _ By my signature below, I certify to each o e followin I am the property owner or authorized agent to act on the property owner's behalf. I have read this application and the information -ha rovid d i o t. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable -local ordinances and state laws rel ing to ui in c str i n. I authorize representatives of Cupertino to enter the above -identified property for inspection purposes. Signature of Applicant/Ag t: Date: _ 4/8/16 PLEMENTAL INFORMATION REQUIRED OFFICE USE ONLY W ❑ OVER-THE-COUNTER ' F ❑ -EXPRESS „ x ❑ STANDARD U ❑ :LARGE Q .a e. �❑ ''MAJOR PVApp 2011.doc revised 03116111 W PHOTOVOLTAIC SYSTEM SYSTEM SIZE: AC / DC kW STC: 4.009kW \ 4.59kW Cc .. � EQUIPMENT: ASSESSOR COPY A - uurvINILIN TY DEVELOPMENT DEPAI ITMENT PV MODULES: (18) Trina Solar TSM-255 PG,a.05 BUIL ING DIVISION - CUPERTI 'O INVERTER(S): (1) ABB PVI-3.8-OUTD-S-US-A APPROVID _ nd sFeciflcations MI.I9 he kept at the SCOPE OF WORK: ob site dLlrin*� co, truction. It Is un'nY charir.;s or alte bons on same INSTALLATION OF A SAFE AND CODE -COMPLIANT --'rom, without ap ; `~om the GRID -TIED SOLAR PV SYSTEM ON AN EXISTING RESIDENTIAL ROOF TOP. of this nl� necific- ?T PPro`, n APN : 36930031 jrdinc_ ,' _A G- o LK > REcEiv ED z _ _ _ ...... ----- - 0 i 3 RY ROOF 3 ARRAY 3 x O SITE PLAN > O ROOF MOUNTED N < CONDUIT (TYP.) SCALE : N.T.S. ROOF ARRAY 2 W ry 0 LAS ONDAS CT sunGEVITY GENERATE POSITIVE PLQr PLAN5 9HECKED BY DATE PLANNING DEPT CUPERTINO CUPERTINO r r,� Building Department IEVVECI i= R CODc COMPLIANCE Rev d 13y - _` PV0.0 COVER AND SITE PLAN PV1.0 GENERAL NOTES PV2.0 - 2.1 ARRAY LAYOUT PV3.0 LINE DIAGRAM PV4.0 LABELS ■L KEY: - PROPERTY LINE - - - CONDUIT RUN Q INVERTER DRIVEWAY Q SUBPANEL -- FENCE a DC DISCONNECT FIRE CLEARANCE a AC DISCONNECT STRUCTURAL UPGRADES I]I]I] JUNCTION BOX SOLAR MODULE I] MONITORING UNIT Q MAIN SERVICE PANEL Q COMBINER BOX Q UTILITY METER ROOF Q PV METER OBSTRUCTION APPLICABLE CODES: 2013 CEC (BASED ON 2011 NEC) 2013 CBC 2013 CRC 2013 CPC 2013 CMC 2013 CFC LOCAL AMENDMENTS TO CA CODES CONTRACTOR INFORMATION: JE SANDBAR SAN JOSE 2119 DELAWARE AVE SANTA CRUZ, CA 95060 JURISDICTIONAL INFORMATION: CUPERTINO, CITY OF 10300 TORRE AVENUE CUPERTINO, CA 95014 NOTES TO INSTALLER: FOR INSTALLER USE ONLY POST INSTALL SUNEYES REQUIRED? NO I CERTIFY THAT NO CHANGES HAVE c BEEN MADE TO THE ARRAY LAYOUT: CUSTOMER INFORMATION: RAKESH HASMUKH PATEL 20087 LAS ONDAS CT. CUPERTINO, CA 95014 (408) 366-2624 / #2533333 DESIGNED BY: REV #: DATE: AM 0 4/6/16 PV- 0.0 •,�.+� •. , • ,,.- w nwvnuN a � J VI , c - vn _u , - -.1 or. w-n-n c I nwc I IUN3, AND DESRiNa - - nc rnvrtrc I r Ur SUNUtV1 I r IN(;. NO FAK I bMALL et curltU UK USED FOR OR WITH ANY OTHER WORK OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT OUR WRITTEN CONSED GENERAL NOTES: GENERAL NOTES: N1. DRAWINGS ARE DIAGRAMMATIC ONLY. THE LOCATION AND ROUTING OF RACEWAYS SHALL BE DETERMINED BY THE CONTRACTOR UNLESS OTHERWISE NOTED OR STANDARDIZED. N2. ALL EQUATIONS ACCOUNT FOR WORST CASE CONDITIONS. N3. IF A DISCREPANCY IN QUANTITY OR SIZE OF CONDUIT, WIRE, EQUIPMENT DEVICES, OVERCURRENT PROTECTION, GROUNDING SYSTEMS, ETC. (ALL EQUIPMENT AND MATERIALS) THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIALS AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS IN THE SPECIFICATIONS OR NOTED ON THE PLANS TO ENSURE COMPLETE COMPLIANCE WITH ALL CODES AND TO ENSURE THE LONGEVITY AND SAFETY OF THE OPERABLE SYSTEM. N4. ALL OUTDOOR EQUIPMENT SHALL BE MIN. NEMA 3R RATED. N5. METAL CONDUIT AND ENCLOSURES SHALL BE USED WHERE PV SOURCE OR OUTPUT CIRCUITS ARE RUN INSIDE A BUILDING. N6. MODULES SHALL NOT BE PLACED OVER ANY PLUMBING VENTS AND AT LEAST 611 ABOVE FLUSH VENTS. N7. THE ELECTRICAL CONTRACTOR SHALL COMPLY WITH ANY AND ALL REQUIREMENTS GIVEN BY UTILITY COMPANIES. N8. FOR ADDITIONAL EQUIPMENT SPECIFICATIONS, SEE PROVIDED CUT SHEETS. N9. ALL LABELS AND MARKINGS SHALL BE ATTACHED ACCORDING TO REQUIREMENTS BY NEC AND THE LOCAL AHJ. THE AHJ MAY HAVE SPECIAL LABEL REQUIREMENTS BEYOND THE 3 SCOPE OF THIS DOCUMENT. THIS MAY ENCOMPASS LANGUAGE INCLUDING, BUT NOT LIMITED TO, THAT FOUND IN NEC ARTICLES 690.5 (C), 690.14 (C)(2), 690.17, 690.53,690.35(F), 690.54, 690.64(B)(7) and 705.10 N10. INSTALLER TO FOLLOW ALL LOCAL JURISDICTION GUIDELINES. N11. ALL NEC REFERENCES SHALL BE DIRECTLY INTERCHANGEABLE WITH CEC REFERENCES. N12, IT IS ILLEGAL FOR ANYONE UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFFESIONAL ENGINEER OR REGISTERED ARCHITECT TO ALTER ANY ITEMS ON THIS PLAN. N13. THE ENGINEER HAS NOT BEEN RETAINED FOR JOB SUPERVISION. N.14 ALL OSHA REGULATIONS AND STANDARDS FOR SAFE AND HEALTHFUL WORKING CONDITIONS TO BE FOLLOWED. N.15 ALL CONTRACTORS WORKING ON ROOFS TO BE INSURED AS SUCH. STRUCTURAL NOTES: S1. MOUNTS ARE DIAGRAMMATIC AND EXACT LOCATION MAY CHANGE, BUT SHALL BE ACCURATELY SPACED. IS2. MOUNTS SHALL BE STAGGERED WHEN NECESSARY TO EVENLY DISTRIBUTE LOAD AMONGST RAFTERS. S3. DO NOT SPLICE RAILS IN MIDDLE 50% OF SPAN BETWEEN TWO MOUNTS. woo sunGEVITY GENERATE POSITIVE ELECTRICAL NOTES: E1. ALL EQUIPMENT IS LISTED FOR USE. E2. MAXIMUM VOLTAGE DOES NOT EXCEED 600VDC. E3. ANY EQUIPMENT OR ELECTRICAL MATERIALS USED FOR THIS INSTALLATION SHALL BE NEW AND LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY. E4. AN INVERTER IN AN INTERACTIVE SOLAR PV SYSTEM SHALL AUTOMATICALLY DE -ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THAT SYSTEM AND SHALL REMAIN IN THAT STATE UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED. E5. ALL PV ARRAYS SHALL BE EQUIPPED WITH DC GROUND FAULT PROTECTION. E6. ANY AC COMPONENT SHALL MEET OR EXCEED THE AVAILABLE FAULT CURRENT CALCULATED AT THAT COMPONENT. E7. ALL MODULES AND ANY RELATED ROOF MOUNTED METALLIC EQUIPMENT SHALL BE PROPERLY GROUNDED. E8. DC EQUIPMENT SHALL BE 60OVDC RATED MINIMUM. E9. MARKINGS SHALL BE PROVIDED TO INDICATE THAT ALL CONTACTS OF THE DISCONNECT EQUIPMENT MIGHT BE ENERGIZED. E10. CONDUIT RUNS SHALL BE PROVIDED WITH SUFFICIENT WEATHERPROOF PULL BOXES OR JUNCTION BOXES/COMBINER BOXES PER APPROPRIATE JURISDICTIONAL REQUIREMENTS. E11. FOR ANY UNGROUNDED PV SYSTEM, A LABEL READING: "WARNING - ELECTRICAL SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED." SHALL BE PLACED AT EACH JUNCTION BOX, COMBINER BOX, DISCONNECT AND DEVICE WHERE ENERGIZED, UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE. E12. INVERTER(S) SHALL CONTAIN A GROUND FAULT DETECTION AND INTERRUPTION DEVICE. E13. ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND ELECTRICALLY CONTINUOUS. E14. THE POINT OF CONNECTION COMPLIES WITH APPLICABLE CEC/NEC. E15. BACKFED SOLAR BREAKER(S) SHALL BE INSTALLED AT THE OPPOSITE END OF THE CIRCUIT OR FURTHEST AWAY FROM THE MAIN BREAKER. E16. ALL WIRE, VOLTAGES, AMPERAGES AND EQUIPMENT IS SIZED ACCORDING TO TEMPERATURE DERATING AND LOCATION. E17. ONLY COPPER (CU) CONDUCTORS SHALL BE USED. CONDUCTORS SHALL BE STRANDED OR SOLID WITH PROPERLY RATED CONNECTORS. E18. DISCONNECT SHALL BE WIRED SO NO BLADES ARE ENERGIZED E19. ALL MODULES AND RACKING SHALL BE GROUNDED VIA IRON RIDGE RAIL INTEGRATED GROUNDING (PLEASE SEE DATA SHEET) OR WITH TIN PLATED DIRECT BURIAL RATED LAY IN LUGS USING STAINLESS STEEL HARDWARE, STAR WASHERS, AND THREAD FORMING BOLTS. E20. ALL EQUIPMENT SHALL BE GROUNDED, INCLUDING BONDING JUMPERS WHERE NECESSARY ACROSS RAIL SPLICE PLATES TO BOND INDIVIDUAL PIECES OF RAIL. CUPERTINO Building Department L `1 APR O U RE"v`IEWED FOR CODE COMPLIANCE Reviewed By. -- - - . -1. - --L- � I - I C J IU U..r.-- - -1 oY. 1 � . - - -.-,. -- .- -, --- - o11rr, -- 1 1 ■ 11 1-- U-11-vo, --- I IUNZ,. ANU UtsIU- - I - --K I Y OF SUNGtVI I Y IN(-. NU F AK I a-LL at wntu UK UaLU rUK UK VVI I H ANY U I HtH VVUKK U I HtR I HAN I Ht 5KtGIFIG NKUJtC T FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT OUR WRITTEN CONSENT I L SYMBOL KEY: ------- RAIL — — — — RAFTERS ROOF FIRE CLEARANCE �•••••• ...... ••. •.® STRING CONFIG. STRUCTURAL UPGRADES SOLAR MODULE 4 ® MOUNT ® SKYLIGHT ® CHIMNEY I c PLUMBING OR ATTIC VENT ATTIC VENT I I ( ( I I ! �- -- I I I I -- 4 1 I: I I i I I I i I L SERVICE DROP 7r 19'-8" 3 � ARRAY 1 LAYOUT I � I I I i U? I I =L I I I 10'-8" 9'-101, i ARRAY 2 LAYOUT 3 SCALE: 3/16" = 1'7" sunGEVITY' GENERATE POSITIVE � I N I I 12'-1" i i UE TO AY 3 I j 1 y 1 11'-111, ROOF SECTION 2 SCALE: 3/8" = 1'-0" 4 ROOF SECTION 3 MODULE SPECIFICATIONS (18) Trina Solar TSM-255 PD05.05 MODULE WEIGHT: 41 MODULE LENGTH: 64.95 MODULE WIDTH: 39.05 ROOF 1 SPECS RAFTER SIZE: 2X6 NOMINAL RAFTER SPAN: 11' - 8" RAFTER SPACING: 24" ROOF MATERIAL: COMPOSITE SHINGLE ARRAY 1 SPECS NUMBER OF MODULES: 10 TOTAL MOD. WEIGHT (Ibs): 410 RACKING WEIGHT (Ibs): 43.8 ARRAY WEIGHT (Ibs): 453.8 ARRAY AREA (sqft): 176.1 ARRAY DEAD LOAD (Ibs/sqft): 2.6 NUMBER OF MOUNTS: 18 LOAD PER MOUNT(Ibs): 25.2 ARRAY AZIMUTH(') 270 ARRAY TILT(') 24 NUMBER OF FLOORS 1 ROOF 2 SPECS RAFTER SIZE: 2X6 NOMINAL RAFTER SPAN: 9' - 1" RAFTER SPACING: 24" ROOF MATERIAL: COMPOSITE SHINGLE ARRAY 2 SPECS NUMBER OF MODULES: 3 TOTAL MOD. WEIGHT (Ibs): 123 RACKING WEIGHT (Ibs): 16.8 ARRAY WEIGHT (Ibs): 139.8 ARRAY AREA (sqft): 52.8 ARRAY DEAD LOAD (Ibs/sqft): 2.6 NUMBER OF MOUNTS: 6 LOAD PER MOUNT(Ibs): 23.3 ARRAY AZIMUTH(') 180 ARRAY TILT(') 25 NUMBER OF FLOORS 1 5�VPCTiiVld ,( `mo t Building Depatnen' APR 0201' REVIEPEv I OR CODE COMPLIANCE Reviewed By: �. CUSTOMER INFORMATION: ME, ■C ■C RAKESH HASMUKH PATEL 20087 LAS ONDAS CT. CUPERTINO, CA 95014 (408) 366-2624 / #2533333 DESIGNED BY: REV #: :!4 ATE: PV- 2.0 AM 0 6/16 oNucvl i r inl .. oo rlV r UfSl S I Sul It JtU UARLANU, CA V40Ui tJY: AUttSH.MUMI It Uace:— Lotatlon: Haamulch Patel .2533333 SV1 Sheet Size: 11x17 1 HtSt URAIIVIM-1. SreClrlCA I IONS. AND DESIGNS Ant I nt rnvrtH I Y OF SUNGtVI I Y INC. NO rAK I shALL tft coPltU vR UstU FOR OR WITH ANY OTHER WORK OTHER THAN THE SPtCIFIC PROJECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT OUR WRITTEN CONSEN I L J <} J SYMBOL KEY: MODULE SPECIFICATIONS (18) Trina Solar TSM-255 PD05.05 ------- RAIL MODULE WEIGHT: 41 RAFTERS MODULE LENGTH: 64.95 ROOF MODULE WIDTH: 39.05 ROOF 3 SPECS FIRE CLEARANCE 11' ' 9'-10" RAFTER SIZE: 2X6 NOMINAL n.-........ r� STRING CONFIG. RAFTER SPAN: 10' - 5" RAFTER SPACING: 24" STRUCTURAL UPGRADES ROOF MATERIAL: COMPOSITE SHINGLE ARRAY 3 SPECS SOLAR MODULE � MODULES:NUMBER OF o, � , TOTAL MOD. WE GHT(Ibs): 205 � MOUNT m j RACKING WEIGHT (Ibs): 27.2 ® SKYLIGHT i ; ARRAY WEIGHT (Ibs): 232.2 1 ARRAY AREA (sqft): 88.1 ® CHIMNEY I i ( ARRAY DEAD LOAD (Ibs/sgft): 2.6 G PLUMBING OR ATTIC VENT ' � ' ILOAD ( NUMBER OF MOUNTS: 11 21.1 PER MOUNT(Ibs): ATTIC VENT ARRAY AZIMUTH(°) 180 ARRAY TILT(°) 25 NUMBER OF FLOORSC.......-- \FROM ' Building Department-- -- 1r AP 0 2 � I REVIEl% ED FOR CODE COMPLIANCE , I BY Reviewed ARRAY 3 LAYO U T NOTE: MODULES SHALL NOT BE GREATER THAN 8 INCHES ABOVE ROOF COVERING 3 E 3 ROOF SECTION sunGEVITY' GENERATE POSITIVE SOLAR MODU IRONRIDGE XR L-FO( QMSE-LAG SHING COMPOSITE SHINGL 5" X 5/16" - L) 2.5" MIN. EMBEDMENT PI SCRE 2X6 NOMINAL, 24 O 2 MOUNTING DETAIL SCALE : NTS ■1114 CUSTOMER INFORMATION: RAKESH HASMUKH PATEL 20087 LAS ONDAS CT. CUPERTINO, CA 95014 (408) 366-2624 / #2533333 DESIGNED BY: REV #: DATE: AM 1 0 4/6/16 PV- 2.1 JNGEVITY INC. 66 FRANKLIN ST SUITE 310 OAKLAND, CA W07 By: ADEESH.MOHITE Date:— Location: Hasmukh Patel - 2533333 SV1 Sheet Size: 11z17 THESE DRAWINGS, SPECIFICATIONS, AND DESIGNS ARE THE PROPERTY OF SUNGEVITY INC. NO PART SHALL BE COPIED OR USED FOR OR W. T I ANY OTHER WORK OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT OUR WRITTEN CONSEI, c ELECTRICAL KEY: BREAKER —�.— SWITCH Q SCREW TERMINAL FUSE 0 SPLICE EARTH GROUND !T7 CHASSIS GROUND --- GEC EGC ME ,s■ (4) #10 PV-Wire (1) #10 EGC FREE AIR 1 STRING OF 0 8 MODULES 1 STRING OF G 10 MODULES (4) #10 THWN-2 (1) #10 EGC 1/2" EMT (IF APPLICABLE) MIN. NEMA3R UL LISTED JUNCTION BOX WITH 90'C TERMINAL RATINGS LOCATED ON ROOF ■ (3) #10 THWN-2 (3) #10 THWN-2 (1) #8 GEC (1) #8 GEC 1/2" EMT 1/2" EMT (N) PVI-3.8-OUTD-S-US-A INVERTER W/ INTEGRATED DC DISCONNECTS MPPT 1 LOCUS \- AC METER DC —000 OUTPUT — — — — — — — GE---- -- —� MPPT 2 INVERTER ■ (E) LOADS (E) LOADS 20A 2P MAX Voc = 10 x [38.1V + (38.1V x-0.0032 x (0°C - 25°C))] = 411VDC CONDUIT ELEVATION: 1/2 TO 3-1/2" = 22 OC Imax = 8.88A x 1 STRING x 1.25 = 11.1A HIGH AMBIENT TEMPERATURE: 32 °C EXTREME LOW: 0°C 200 x 1.2 = 240 ROOFTOP AMBIENT TEMP (Tcorr): 54°C = 0.76 240 - 200(MCB) = 40A CONDUIT FILL (Cfill): 0.8 �•� MAX ALLOWABLE AC PV BREAKER = 40A CONTINUOUS USE = Imax * 1.25 = 13.88A CONDITIONS OF USE = Imax / Tcorr / Cfill = 11.1 A/0.76/0.8 = 18.26A S U nG E V I T Y CONDUCTOR SIZE FOR 18.26A GENERATE POSITIVE INSTALLATION SHALL USE MIN. #10 AWG (v ■ 200A MAIN BREAKER METER (E) 200A Murray MSP 240V 2P 3-W 1 I I GEC IRREVERSIBLY SPLICED TO EXISTING GEC OR BONDED DIRECTLY TO EXISTING GROUNDING ELECTRODE 0 MODULE ELECTRICAL SPECIFICATIONS (18) Trina Solar TSM-255 PD05.05 SHORT CIRCUIT CURRENT (Isc) 8.88 OPEN CIRCUIT VOLTAGE (Voc): 38.1 OPERATING CURRENT (IMP) 8.37 OPERATING VOLTAGE (VMP): 30.5 MAX SERIES FUSE RATING: 15 STC RATING: 255 PTC RATING 232 DESIGN CONDITIONS HIGHEST 2% DB DESIGN TEMP (°C): 32 MIN. MEAN EXTREME ANNUAL DB (°C): 0 INVERTER 1 SPECIFICATIONS ABB PVI-3.8-OUTD-S-US-A RATED WATTS (EACH): 4200 AC OPERATING VOLTAGE (V): 240 AC OPERATING CURRENT (A): 16 NUMBER OF MPPT CHANNELS 2 INVERTER EFFICIENCY 0.96 INTEGRATED DC DISCONNECT INVERTER 1 MPPT 1 SPECIFICATIONS MAXPOWER POINT CURRENT (Imp): 8.4 MAX POWER POINT VOLTAGE (Vmp): 244 MAX SYSTEM VOLTAGE (Voc): 328.8 SOURCE CIRCUIT CURRENT (Isc): 11.1 MAX SHORT CIRCUIT CURRENT (Isc): 11.1 INVERTER 1 MPPT 2 SPECIFICATIONS MAXPOWER POINT CURRENT (Imp): 8.4 MAX POWER POINT VOLTAGE (Vmp): 305 MAX SYSTEM VOLTAGE (Voc): 411 SOURCE CIRCUIT CURRENT (Isc): 11.1 MAX SHORT CIRCUIT CURRENT (Isc): 11.1 ■C Building Department �s 0 24 REVIEYVVLO FOR CODE COMPLIANCE Reviewed Byy 18 MODULES TOTAL 18 x 232(PTC WATTS) x 0.96 = 4009 CEC WATTS PVI-3.8-OUTD-S-US-A MAX OUTPUT CURRENT = 16A BREAKER SIZE = 16A x 1.25 = 20A => 20A ■C CUSTOMER INFORMATION: RAKESH HASMUKH PATEL 20087 LAS ONDAS CT. CUPERTINO, CA 95014 (408) 366-2624 / #2533333 DESIGNED BY: REV #-I DATE: PV- 3.0 AM 0 1 4/6/16 --- I oo 1-111uN .1 Jui I c o Iu ur.nuarvu, uh y.out oy. Autr- n.munl i e uate.— LOCanon. HaSMUKl1 Patel - ZS33333 SV 1 Sheet SIZe: 11 X 1 / I ntJt UNAMNua arculrlOA I IONS. AND DESIGNS AKt Inc rnurtK I Y OF SUNG EVITY INC. NO PAR I SHALL tst UUFItU rJR UStU FOR UR VVI I H ANY U I HtK N/URK U I HtR I HAN I Ht SF'tCIFIC PROJECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT OUR WRITTEN CONSEW L J 4 NEC 690.5(c) PLACE THIS LABEL ON INVERTER(S) OR NEAR GROUND -FAULT INDICATOR (ON INVERTER(S) U.O.N.) WARNING ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED NEC 690.17(E) PLACE THIS LABEL ON ALL DISCONNECTING MEANS WHERE ENERGIZED IN AN OPEN POSITION WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION NEC 705.12(D)(2)(b) PLACE THIS LABEL AT P.O.C. TO SERVICE DISTRIBUTION EQUIPMENT (I.E. MAIN PANEL (AND SUBPANEL IF APPLICABLE)) WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE NEC 705.12(D)(3) PLACE LABEL ON ALL EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR OR CONDUCTORS SUPPLIED FROM MULTIPLE SOURCES. CAUTION CONTAINS MULTIPLE POWER SOURCES NEC 690.31 (E) 3 & 4; 2012 IFC 605.11.1 PLACE ON ALL JUNCTION BOXES, EXPOSED RACEWAYS EVERY 10' AND V FROM BENDS AND PENETRATIONS, ADJACENT TO THE MAIN SERVICE DISCONNECT WARNING PHOTOVOLTAIC POWER SOURCE NEC 690.35(F) PLACE THIS LABEL AT EACH JUNCTION BOX, COMBINER BOX, DISCONNECT AND DEVICE WHERE ENERGIZED, UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE: WARNING ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED INTERACTIVE PHOTOVOLTAIC POWER SOURCE RATED AC OUTPUT CURRENT (A): 16 NOMINAL OPERATING AC VOLTAGE (V): 240 INVERTER 1 MPPT 1 DC DISCONNECT PHOTOVOLTAIC SYSTEM DISCONNECT RATED MAX POWER POINT CURRENT (Imp): 8.4 RATED MAX POWER POINT VOLTAGE (Vmp): 244 MAX SYSTEM VOLTAGE (Voc): 328.8 SHORT CIRCUIT CURRENT (Isc): 11.1 INVERTER 1 MPPT 2 DC DISCONNECT PHOTOVOLTAIC SYSTEM DISCONNECT RATED MAX POWER POINT CURRENT (Imp): 8.4 RATED MAX POWER POINT VOLTAGE (Vmp): 305 MAX SYSTEM VOLTAGE (Voc): 411 SHORT CIRCUIT CURRENT (Isc): 11.1 CUPERTINO Building Department AP? o 201S RE\,! ED FOR CODES COMPLIANCE Reviewed By: /�-� L I sunGEVITY GENERATE POSITIVE SUNGEVITY INC. 66 FRANKLIN ST SUITE 310 OAKLAND, CA 94607 By: ADEESH.MOHITE Date:— Location: Hasmukh Patel - 2533333 SV1 Sheet Size: 1107 THESE DRAWINGS, SPECIFICATIONS, AND DESIGNS ARE THE PROPERTY OF SUNGEVITY INC. NO PART SHALL BE COPIED OR USEU FOR OR WI I H ANY 0 1 HER WUHK 0 1 HER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN ULVtLUPtU INI I ROUT OUR WRITTEN CONSENT Mono Multi Solutions THE Universal 60 CELL MULTICRYSTALLINE MODULE 245 -265W POWER OUTPUT RANGE 16.2% MAXIMUM EFFICIENCY 0P%w+3%o POSITIVE POWER TOLERANCE As a leading global morwfacturer of next generation photovoltaic products. we believe close cooperation with our partners Is crifica; to success. With local presence around the globe, Trino is able to provide exceptional service to each customer in each market and supplernent our innovative, reliable products with the backing of Trina as a strong. bankable partner. 'Ne are Committed to building strategic, mutually beneficial collaboration with installers, developers, distributors and other partners as the backbone of our shared success in driving Smart Energy Together. Trina Solar Limited Trinasolar Smart Energy Together PD05.08 PD05 PD05.05 Our most versatile product 1� • Compatible with all major 3O5 components and system designs • 1000V ! IL/1000V IEC certified One of the industry's most trusted modules ai • Field proven performance Highly reliable due to stringent quality control • Over 30 in-house tests (UV, TC, HF, and many more) • In-house testing goes well beyond certification requirements • PID resistant Certified to withstand challenging environmental conditions • 2400 Pa wind load • 5400 Pa snow load LINEAR PERFORMANCE WARRANTY 10 Year Product Warranty • 25 Year Linear Power Warranty m100% Addiliogal ovalue /tom ulna Solar s litre 90% `o ar Warranty 0 80% Years 5 10 15 20 25 0 Trinastandard 0Industry>tcmdard CUPERTINO Building Depart In L . . i APR, 0 9015 THF. Universal MODULE IFS/Il=lh_P7I-) �:r)Q (C"I FlP 1`1nhA01 1AkI(`r .7 RP\iiPwr rim PRODUCTS POWER RANGE ELECTRICAL DATA (STC) TSM-PD05 250-265W Peak Power Watts-PMAx (Wp) 245 250 255 260 265 TSM-PD05.08 250-265W Power Output Tolerance-PNax (%) 0 - +3 TSM-PDO5.05 245-26OW Maximum Power Voltage-VMrP (V) 29.9 30.3 30.5 30.6 30.8 Maximum Power Current-IMPP (A) 8.20 8.27 8.37 8.50 8.61 DIMENSIONS OF PV MODULE Open Circuit Voltage-Voc (V) 37.8 38.0 38.1 38.2 38.3 unit:mm Short Circuit Current-Isc (A) 8.75 8.79 8.88 9.00 9.10 941 Module Efficiency 0m (%) 15.0 15.3 15.6 15.9 16.2 STC: Irradiance 1000 W/m', Cell Temperature 25'C, Air Mass AM1.5. a (UNCTION c Typical efficiency reduction of 4.5%at 200 W/m' according to EN 60904-1. BOX NAMEPLATE y, 9.12 ELECTRICAL DATA (NOCT) INSTALLING HOLE i; Maximum Power-Pwx(Wp) 182 186 190 193 197 Maximum Power Voltage-VMPP (V) 27.6 28.0 28.1 28.3 28.4 i Maximum Power Current -Imp? (A) 6.59 6.65 6.74 6.84 6.93 o Open Circuit Voltage-Voc (V) 35.1 35.2 35.3 35.4 35.5 Short Circuit Current-Isc (A) 7.07 7.10 7.17 7.27 7.35 NOCT: Irradiance at 800 W/m', Ambient Temperature 20"C, Wind Speed 1 m/s. MECHANICAL DATA 6-0 C.3 GROUNDING HOLE �- A A Solar cells Multicrystalline 156 x 156 mm (6 inches) 1:�ORAIN HOLE Cell orientation 60 cells (6 x 10) --- Module dimensions 1650 x 992 x 35 mm(64.95 x 39.05 x 1.37 inches) 812 180 Weight 18.6 kg (41lb) Back View Glass 3.2 mm(0.13 inches),High Transmission, AR Coated Tempered Glass _ Backsheet White(PD05&PD05.08): Black(PDO5.05) u I Frame Silver Anodized Aluminium Alloy (PD05); Black(PDO5.08&PDO5.05) J-Box IP 65 or IP 67 rated M===. Cables Photovoltaic Technology cable 4.Omm' (0.006 inches=), 1000mm(39.37inches) Connector MC4 Compatible 35 1 A -A I-V CURVES OF PV MODULE (26OW) 10.00 9.00 e.00 T 00 t 600 500 V 4.00 :.00 , 00 000 0 TEMPERATURE RATINGS Nominal Operating Cell 44-C (+2,C) Temperature (NOCT) Temperature Coefficient of PMAx -0.41%/°C Temperature Coefficient of Voc - 0.32%/"C Temperature Coefficient of Isc 0.05%/°C MAXIMUM RATINGS Operational Temperature-40-+85°C Maximum System 1000V DC(IEC) Voltage IOOOV DC (UL) Max Series Fuse Rating 15A WARRANTY 10 year Product Workmanship Warranty 25 year Linear Power Warranty (Please refer to product warranty for details) < I 0 N t C E c& PACKAGING CONFIGURATION 0 usreo Modules per box: 30 pieces z' Modules per 40' container: 840 pieces y PV-L`YCL[ ��M . .... . ... . ....... ...... . ... to :o m w so vollow) CERTIFICATION CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. Trines solar IID 2015 Trina Solar Limited. All rights reserved. Specifications included in this data sheet are subject to change without notice. Smart Energy Together CERTIFICATE OF COMPLIANCE Certificate Number 20140630-E306515 Report Reference E306515- 20121213 Issue Date 2014-J U N E-30 Issued to: TRINA SOLAR LTD 2 TIAN HE RD, ELECTRONICS PARK NEW DISTRICT, CHANGZHOU, JIANGSU 213031 CHINA, This is to certify that PHOTOVOLTAIC MODULES AND PANELS WITH representative samples of SYSTEM VOLTAGE RATINGS OVER 600 VOLTS Refer to addendum page for Models Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: UL 1703 - Standard for Safety for Flat -Plate Photovoltaic Modules and Panels and ULC ORD/C1703-01 - Flat -Plate Photovoltaic Modules and Panels. Additional Information: See the UL Online Certifications Directory at www.ul.com/database for additional information Only those products bearing the UL Listing Mark for the US and Canada should be considered as being covered by UL's Listing and Follow -Up Service meeting the appropriate requirements for US and Canada. The UL Listing Mark for the US and Canada generally includes: the UL in a circle symbol with "C" and "US" identifiers: c @," the word "LISTED"; a control number (may be alphanumeric) assigned by UL; and the product category name (product identifier) as indicated in the appropriate UL Directory. Look for the UL Listing Mark on the product. f :UPER ► NO B ilding Department i APR 0 Z REVIEWED FOR COD COMPLIANCE Reviewed By �- /�, , � 47. William R. Carney, Director, North American Certification Programs UL LLC Any Information and documentation Involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at -ul.comlcontactus CERTIFICATE OF COMPLIANCE Certificate Number Report Reference Issue Date 20140630-E306515 E306515-20121213 2014-JUNE-30 The modules with the specified construction as below may be marked with its type for UL listed fire performance products only as the below table: Module model Specific construction Marking TSM-xxxPD05, Superstrate: 3.2-4.36mm thick; Module Fire TSM-xxxPD05.08 EVA: 0.25-0.61mm thick; Performance: Substrate: 0.30 mm - 0.64 mm Type 1 thick; Frame: Cross sectional dimension: 35 x 35mm, Height: 35mm, Thickness: 1.5mm TSM-xxxPD05 Superstrate: 3.2-4.36mm thick; Module Fire TSM-xxxPD05.05, EVA: 0.25-0.61mm thick; Performance: TSM-xxxPD05.08 Substrate: 0.284 mm - 0.30 mm Type 2 thick; Frame: Cross sectional dimension: 35 x 35mm, Height: 35mm, Thickness: 1.5mm TSM-xxxPD14, Superstrate: 3.2-4.36mm thick; Module Fire TSM-xxxPD14.08 EVA: 0.25-0.65mm thick; Performance: Substrate: 0.284 mm - 0.300 mm Type 8 thick; Frame: Cross sectional dimension: 40*35 mm, Height: 40mm, Thickness: 1.5 mm TSM-XXXPD05.10 Superstrate: 3.2-4.36mm thick; Module Fire TSM-XXXPD05.18 EVA: 0.25-0.65 mm thick; Performance: Substrate: 0.025 - 0.284 mm Type 5 thick; Frame: Cross sectional dimension: 40* 38 mm, Height: 40mm, Thickness: 1.8mm /J�le 47 William R. Camey, Director, North American Certification Programs L UL LLC YY Any information and documentation Involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at www.ul.coMcomaetus Page 1 of 4 Page 3 of 4 This family of single-phase string inverters complements the typical number of rooftop solar panels enabling homeowners to get the most efficient energy harvesting for the size of the property. This inverter offers a dual input section that processes two strings with independent Multiple Power Point Tracking (MPPT), This is especially useful for rooftop installations with two different orientations from two sub -arrays oriented in different directions, or unbalanced strings (for example: East and West). The dual -input sections with independent MPPT enable a more optimal energy harvesting condition. The high-speed MPPT offers real- time power tracking and improved energy harvesting. The flat efficiency curve ensures high - efficiency at all output levels allowing a consistent and stable performance across the entire input voltage and output power range. The transformerless operation gives the highest efficiency of up to 97.0 percent. The wide input voltage range makes the inverter suitable to low -power installations with reduced string size. This rugged, outdoor inverter has been designed to be a completely sealed unit, to withstand the harshest environmental conditions. e arim r oNIS ��.� ....� FIANCE r R cope CO�p t" t- V Ftev1ewed B1, Highlights: — Single-phase and three-phase output grid connection — Wide input -voltage range for increased stringing flexibility and energy harvesting — The high-speed and precise MPPT algorithm offers real-time power tracking and improved energy harvesting — Outdoor NEMA 4X rated enclosure for unrestricted use under any environmental conditions — Integrated DC disconnect switch in compliance with international Standards (-S Version) Power and productivity „ 11 ,N for abetter worlds" JIMPIP Additional highlights - RS-485 communication interface (for connection to laptop or data logger) - Available with the optional VSN300 Wifi Logger Card for easy and affordable wireless monitoring - Compliant with NEC 690.12 when used with ABB's Rapid Shutdown device - Comes standard with DC Arc Fault Circuit Interruptor (AFCI) to comply with NEC 690.11 Technical data and types Type code PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US PVI-4.2-OUTD-US General specifications Nominal output power 3000W 360OW 3W0 380OW 420OW 3000 3300' 3300' ..................................................... 3600 4000' 4000' 3300 4200' 4200' '. 4200 4600' 4600' Maximum output power wattage w w w W W W W w W w w w Rated grid AC voltage ............:.............................................................................. ....................:....................:....27 208V 240V 2 7V V 4 V 277V i 208 2 0 2 V 08 24 V 277V 2 V 24 V 277V 0 08 0 NUmOef OT Independent mh,Fj I CnannelS Y L L Z Maximum usable power for each channel 2000W 3000W 3000W 3000W ......... ................................,......................... Absolute maximum voltage..(Vmax).........................5........................................................................I............................. ..... ............................._...................................... 600V ........................................ Startup voltage (Vstart).................................................................................................................................. .. 200V (adl...120-350V)... ............. ............. .. ..............._ Full power MPPT voltage range 160-530V ................... 120-530V 140-530V ............................_.......................................I..................... 140-530V Operating MPPT voltage range 0.7 x Vstart - 580V (>_90V) . . ..................._........................................................................................................ M xim m current Idcmax for both in a u e ( ) 20A 20A = 32A 32A 32A parallel...................................................................................................................... Maximum usable current per channel .. ...... ... 10A ....................................................._..................._...................:............................................................................. 16A 16A 16A Maximum short circuit limit per 12.5A 20.OA 20.OA 20.OA channel Numberof wire landing.. terminals per channel ..................................... _ ..........................................................................................................................Pairs......................................................... Array wiring termination Terminal block, pressure clamp, AWG20-AWG6 Grid connection type IV)/ opus- IVJ/ I W/ oplu- I soi V)/ OpIIL- i I10/ I soi opnt- . i Ivi 2W 0/3W 2W 2W [ 0/3W 2W i 2W 0/3W 2W 2W 0/3W i 2W ..........................-................................................................................................................................................._.......................................,.........................................._..................._ Adjustable voltage range (Vmin-Vmax) M 183- 211- i 244- 183- 211- [ 244- 1 183- 211- 244 183 211- 244- : 228V 264V [ 304V 228V i 264V [ 304V 228V 264V 304V 228V 264V 304V ........................................................................................................_................................................................................................................................................................................................................................._.................... Gridfrequency............................................................................................................................................ 60Hz Adjustablegrid frequency range ...................................`.................... ..................... ..................... ..................................................57-60.5Hz Maximum current (I.,) 14.5A 14.5A 12.OA 17.2A 16.OA 16.OA 16.OA 16.OA 16.OA 20.OA 20.OA 20.OA .............................................................................:....................:....................:....................:....................:....................:....................:......................................:..................._.......................................:.................... Power factor > 0.995 (adjustable to t0.8) Total harmonic distortion at rated power ......._...........................__.........................................__....._..__................................................_....._.........._.........................................................._......................................................................................................................................_ ............ .................................................. < 2% ......................................... Grid wiring termination type Terminal block, Pressure clamp, AWG20-AWG6 heverse poianty. protection Yes .......................... ....................... . Over voltage protection type Varistor, 2 for each channel ................................... ................................................................................................................ PV array ground fault detection Pre start-up R,,, and dynamic GFDI (requires floating arrays) Anti-islanding protection Meets UL1741 / IEEE1547 requirements ..............................................;...................................................... ... ...... ...... ........ ............... Over voltage protection type Varistor, 2 (L, - L2 / L, - G) Maximum AC OCPD rating 20A 20A 15A i 25A 20A i 20A 20A 20A 20A 25A 25A ! 25A Efficiency Maximum efficiency 96.9% 97% 97% 97% ..........................._........................................................_..._.........................................................:.............................................................................................I......................_..:...........__............._..............._........ CEC efficiencv 96% Nlgnttime consumption ...................... _.. _... �..u.t)w.aMs. .............. _..... Stand-by consumption < 8w.„ Communication User -interface 16 characters x 2 lines LCD display .... ......... .......... ......... Remote monitoring (1 xRS485 incl.) ............. .................. ..... .. ............ .......... ..................... _ VSN700 Data Logger (opt.), VSN300 Wifi Logger Card (opt.) Environmental Ambient air operating temperature range -130F to +140OF (-25°C to 60°C) with derating above 122°F (50°C) .. ........... . Ambient air storage temperature range ........... -40OF to +1760F (-40°C to +80°C) .. ................ Relative humidity ......... ......... .................... ............... ............. 0-100% RH condensing Acoustic noise emission level < 50 db A @1 m ( ) ...... . ........................................................................................................,.......................................................................................................................................................................................... ..Maximum operating. altitude without derating........................................................... .............. ........................... .................... _ .............................................. ... .....6560ft..(2000m)............................................................... .................... .................... . 1. Capability enabled at nominal AC voltage and with sufficient DC power available. 2 ABB solar inverters I Product flyer for PVI-3.0/3.6/3.8/4.2-TL-OUTD Block diagram of PVI-3.013.613.814.2-TL-OUTD ----- r----------, .--------- ------------------ MPPT 1 INVERTER I (DCOO BULK CAPS(DC/AL) LINE GRID PARALLEL IN12(+)r l--+--11+ �I + FILTER RELAY LI � INi INl � � IN7 INl � I � INl INI I I N IN1.11-I I �1 O— _ L2 IN73(-) 1 DC - - - - - - I IDC/D0 T f W] yI IN22(+) IN2 I �� RESIDUAL CURRENT DETECTION IN2 ,,L ,ILIN2 IN2 I I IN2 PE IN2.21-) 1 +T/R i I i , i •__ .__________. , RTN I _ STANDARD VERSION -AVERSION -S VERSION ' - - ______- - - - - - - �- - - ___________ ' REMOTE CONTROL' 1 ,______------ DGDC DC/AC DSP DSP __________________ � CONTR. CONTR. f+R P P —{_ R OE ECnrnoN ALARM N.0 N.0 CONTROLORCUR C L------------------------------------------------------------------------------ Remote control function not available on -A version PVI-4.2-OUTD-US — 200 Vdc —MVdc 3 480 Vdc 91 0% Ivn Zt eo% ,v% 60% 609b '09' B0% 90% 100% Output % of Rated t Power Technical data and types PVI-4.2-OUTD-US es� rxaow Ne nm` wa v- �„ s sAoa Safety and Compliance Isolation level Transformerless (floating array) .... .................. ............. ........ ................ Safety and EMC standard UL1741, IEEE1547, IEEE1547.1, CSA-C22.2 N. 107.1-01, UL1998 UL 16998, FCC Part ....... .. 15 Class B..._._ .. Safety approval CSAa ............. ............_.............. ..... __........._._.......,....................'. Regional Compliance Rule 21, HECO, NEC 2014 690.11, NEC 690.12 with ABB Rapid Shutdown device With switch, wiring box, arc fault detector and PVI-3.0- U - - VI-3.6-CUTD-S- PVI-3.8-OUTD-S- PVI-4.2-OUTD-S- interrupter ............ ........ ... .......................... �S.:A.. US -A. US -A US A.._ ... 2. When equipped with optional DC switch and wiring box. All data is subject to change without notice Product flyer for PVI-3.0/3.6/3.8/4.2-TL-0UTD I ABB solar inverters 3 C 1A CSA Group Certificate of Compliance Certificate: 2708406 Project: 2722409 Issued to: ABB, Inc. 16250 W. Glendale Drive New Berlin, WI 53151 USA Master Contract: 259813 Date Issued: April 24, 2014 The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only. Issued by: Jocelyn Jens Product Group Coordinator CP C us Authorized by: Lindsay Clark Operations Manager PRODUCTS CLASS 5311 09 - POWER SUPPLIES - Distributed Generation Power Systems Equipment CLASS 5311 89 - POWER SUPPLIES - Distributed Generation - Power Systems Equipment - Certified to U.S. Standards Utility Interactive Inverter, Models PVI-4.2-OUTD-US, PVI-3.8-OUTD-US, PVI-3.6-OUTD-US, PVI-3.0-OUTD-US, PVI-4.2-OUTD-S-US, PVI-3.8-OUTD-S-US, PVI-3.6-OUTD-S-US, PVI-3.0-OUTD-S-US, PVI-4.2-OUTD-S-US-A, PVI-3.8-OUTD-S-US-A, PVI-3.6-OUTD-S-US-A, PVI-3.0-OUTD-S-US-A, PVI-4.2-OUTD-US-W, PVI-3.8-OUTD-US-W, PVI-3.6-OUTD-US-W and PVI-3.0-OUTD-US-W; provided with two DC input channels, permanently connected, system ratings as follows: Notes: 1. All above models in this series may include expansion board with wireless antennae option and will be identified with model designation including "—Z" suffix. 2. For details related to rating, size, configuration, etc. reference should be made to the CSA Certification Record or the Certificate of Compliance Annex A. CUPERTINO f Building Iding Departrnent — _ APR 0 t, 2016 REVIEWLED FOR CODE COMPLIANCE Reviewed By IRONRIDGE Roof Mount System � AUTHORIZATION TO MARK Built for so,Iar's tc?ua hest roofs. IronRidge builds the strongest roof mounting system in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested All components evaluated for superior structural performance. Class A Fire Rating Certified to maintain the fire resistance rating of the existing roof. Integrated Grounding UL 2703 system eliminates separate module grounding components. PE Certified Pre -stamped engineering letters available in most states. Design Software Online tool generates a complete bill of materials in minutes. 20 Year Warranty Twice the protection offered by competitors. This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location -of the, Party Authorized To Apply Mark. Applicant: IronRidge, Inc. Manufacturer: IronRidge, Inc. Address: 1495 Zephyr Ave Address: 1435 Baechtel Road Hayward, CA 94544 Willits, CA 95490 Country: USA Country: USA Contact: Yann Schwarz Contact: Jim Norsworthy Phone: (800) 227-9523 Phone: (800) 227-9523 (510) 225-0973 FAX: (707) 459-1833 FAX: (707) 459-1833 Email: yschwarz@ironridge.com Email: jorswothy@ironridge.com Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Lake Forest, CA Control Number: 4007559 Authorized by: for Thomas J. Patterson, Certification Manager ETL C LASS IF] ED Us 1 E' Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek's Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 UL Subject 2703 Outline of Investigation for Rack Mounting Systems and Clamping Devices for Flat -Plate Standard(s): Photovoltaic Modules and Panels, Issue Number: 1, October 4, 2010 Product: XR Rails with Integrated Grounding. Brand Name: N/A Models: 51-61GD-005, 51-61GD-005B, 51-5000-001, and 51-65-001 = CUPERTINO Building APR 0 8 2015 zEVIEVVED I OR CODE COMPLIANCE F2eVle''ATM Issued: 10-Nov-2014 �. ATM for Report 101541132LAX-002 Page 1 of 3 ED 16.3.15 (1-Jan-13) Mandatory RON RI DGE Simplified Grounding For Greater Safety & Lower Cost Traditionally, solar modules are grounded by attaching lugs, bolts or clips to the module frame, then connecting these to a copper conductor that runs throughout the array. This process adds time and cost to the installation, and often results in improper grounding, creating significant long-term safety risks. The IronRidge Integrated Grounding System solves these challenges by bonding modules directly to the mounting rails. This approach eliminates separate module grounding hardware, and it creates many parallel grounding paths throughout the array, providing greater safety for system owners. Grounding Strap Grounding Straps are used to bond rail -to -rail connections. They are only required on the rail with the grounding lug. Integrated Grounding System 1 Grounding Mid Clamp Each Grounding Mid Clamp pierces through the anodized coatings of both the module frame and the mounting rail to form secure electrical bonds, which are repeated throughout the array. Grounding Lug A single Grounding Lug connects an entire row of PV modules to the grounding conductor. Installation Overview Install Roof Attachments - Install appropriate roof flashing and/or standoff for roof type. • Attach L-Feet to flashing or standoff. Prepare Rail Connections - Insert splice into first rail, then secure with Grounding Strap and self -drilling screw. • Slide second rail over splice, then secure with opposite end of Grounding Strap and self -drilling screw. Mount & Ground Rails - Attach rails to L-Feet and level rails. • Install one Grounding Lug per row of modules. • Connect Grounding Lug to grounding conductor. Install Modules & Clamps - Install first module using End Clamps and Grounding Mid Clamps. - Install additional modules using Grounding Mid Clamps. - Finish row with a second pair of End Clamps. Testing & Certification I'B-I Module Frame Compatibility The IronRidge Integrated Grounding I I System has been tested and certified to Dimension Range UL 2703 by Intertek Group plc. A 31.Omm - 51.Omm UL 2703 is a proposed UL standard ° B 5.08mm (minimum) for evaluating solar module mounting Any module frames whose parameters are not listed in the and clamping devices. It ensures these provided table have not been tested for compatibility. devices will maintain strong electrical and mechanical connections over an extended period of time in extreme outdoor I The Grounding Clamp has proven robust in grounding 60-cell and environments. 72-cell solar module frames with box construction and a range of anodization thicknesses. i The testing process closely mirrors that All solar modules listed to UL 1703 and with frame construction of UL 1703, the solar module testing within the parameters stated above are compatible with the standard, including temperature and IronRidge Integrated Grounding System. humidity cycling, electrical and mechanical load testing, and manufacturing quality Go to ironridge.com/ig reviews. s SM <_ Starling Madison Lofquist, Inc. _ o n s ri l t 1 n g S r r u c t a r ,a l .: n ci F i r F n g, i n r, o r s 5224 South 39" Street, Phoenix, Arizona 85040 tel: (602) 438-2500 fax: (602) 438-2505 ROC#291316 www.smleng.com IronRidge December 18, 2014 1495 Zephyr Ave Page 1 of 20 Hayward, CA 94544 Attn: Mr. David F. Taggart, Vice President Products Subject: IronRidge XR10 Rail, Roof Flush Mounting System — Structural Analysis Dear Sir: We have analyzed the IronRidge XR10 Rail for the subject solar module support system and determined that, for the configurations and criteria described below, it is in compliance with the applicable sections of the following Reference Documents: Codes: ASCE/SEI 7-10 Min. Design Loads for Buildings & Other Structures California Building Code 2012 Edition Other: AC428, Acceptance Criteria for Modular Framing Systems Used to Support PV Modules, dated Effective November 1, 2012 by ICC-ES Aluminum Design Manual, 2010 Edition The IronRidge XR10 Rail is an extruded aluminum section with an overall depth of 1.75 in. and a net area of 0.363 sq.in. The rails are used to support solar modules, typically, on the roof of a building. See Exhibit A — attached. The rails are clamped to aluminum angle brackets that are either attached directly to the roof framing or attached to a stand that is screwed to the roof framing. The rails are mounted across the slope with a small clearance (flush mounting) to the underlying roof structure. The installed solar modules are at the same slope as the underlying roof structure. All loads are transferred to the roof framing through the angle brackets by simple bi-axial flexure of the rails. The maximum span of the rails is governed by either the mid -span flexural stresses or the deflection requirement that the rail not come into contact with the roof. The effect of seismic loads (for all design categories A-F) have been determined to be less than the effect due to wind loads in all load conditions and combinations. Therefore, the maximum allowable spans for common load cases are shown in the tables below. Tables IA-9A are for modules with a maximum long dimension of 67.5 inches and Tables 1 B-9B are for modules with a maximum long dimension of 78.5 inches. Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers IronRidge Mr. David F. Taggart IronRidge XR10 Rail, Roof Flush Mounting System — Structural Analysis December 18, 2014 Page 5 of 20 Table 4A - MAXIMUM SPANS (in) - Roof Slope 7° to 27° - Wind Zone 1 (67.5" Max Module Length) XR10 Rail Wind Speed Ground Snow Load Exposure mph 0 psf 10 sf 20 psf 30 psf 40 psf 50 psf 60 psf 70 psf 80 psf 90 psf 100 75 65 55 49 43 39 35 33 31 29 105 75 65 55 49 43 39 35 33 31 29 110 75 65 55 49 43 39 1 35 33 31 29 120 75 65 55 49 43 39 35 33 31 29 Category [3 130 75 65 55 49 43 39 35 33 31 29 140 71 65 55 49 43 39 35 33 31 29 150 66 65 55 49 43 39 35 33 31 29 160 62 62 54 48 43 39 35 33 31 29 170 1 59 59 53 47 43 39 35 33 31 29 100 75 65 55 49 43 39 35 33 31 29 105 75 65 55 49 43 39 35 33 31 29 110 75 65 55 49 43 39 35 33 31 29 120 70 65 55 49 43 39 35 33 31 29 Category C 130 1 65 64 54 48 43 39 35 33 31 29 140 60 60 53 48 43 39 35 33 31 29 150 56 56 52 47 43 39 35 33 31 29 160 53 53 51 46 42 39 35 33 31 29 170 50 50 50 45 41 38 35 33 31 29 100 75 65 55 49 43 39 35 33 31 29 105 73 65 55 49 43 39 35 33 31 29 110 70 65 55 49 43 39 35 33 31 29 120 64 64 54 48 43 39 35 33 31 29 Category D 130 60 60 53 47 43 39 35 33 31 29 140 55 55 52 46 42 39 35 33 31 29 150 52 52 50 46 42 39 35 33 31 1 29 160 49 49 49 45 41 38 35 33 31 29 170 46 46 46 44 40 37 35 33 31 29 Notes — see page 20 �� �li�Ei�Ti iU0 Building Department -�_ APR 0 8 2016 FOR COL)E COMPLIANCE Reviewed By - Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers -5- IronRidge Mr. David F. Taggart IronRidge XR 10 Rail, Roof Flush Mounting System - Structural Analysis December 18, 2014 Page 6 of 20 Table 5A - MAXIMUM SPANS (in) - Roof Slope 7° to 270 - Wind Zone 2 (67.5" Max Module Length) XR10 Rail Wind Speed Ground Snow Load Exposure mph 0 psf 10 psf 20 psf 30 psf 40 psf 50 psf 60 psf 70 psf 80 psf 90 psf 100 72 65 55 49 43 39 1 35 33 31 29 105 69 65 55 49 43 39 35 33 31 29 110 66 65 55 49 43 39 35 33 31 29 120 60 60 55 49 43 39 35 33 31 29 Category B 130 56 56 55 49 43 39 35 33 31 29 140 52 52 52 49 43 39 35 33 31 29 150 49 49 49 49 43 39 35 33 31 29 160 46 46 46 46 43 39 35 33 31 29 170 43 43 43 43 43 39 35 33 31 29 100 61 61 55 49 43 39 1 35 33 31 29 105 58 58 55 49 43 39 35 33 31 29 110 56 56 55 49 43 39 35 33 31 29 120 51 51 51 49 43 39 35 33 31 29 Category C 130 48 48 48 48 43 39 35 33 31 29 140 44 44 44 44 43 39 35 33 31 29 150 41 41 41 41 41 39 35 33 31 29 160 39 39 39 39 39 39 35 33 31 29 170 36 36 36 36 36 36 35 33 31 29 100 56 56 55 49 43 39 35 33 31 29 105 54 54 54 49 43 39 35 33 31 29 110 52 52 52 49 43 39 35 33 31 29 120 47 47 47 47 43 39 35 33 31 29 Category D 130 44 44 44 44 43 39 35 33 31 29 140 41 41 41 41 41 39 35 33 31 29 150 38 38 38 38 38 38 35 33 31 29 160 36 36 36 36 36 36 35 33 31 29 170 33 33 33 33 33 33 33 33 31 29 Notes — see page 20 Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers IronRidge Mr. David F. Taggart IronRidge XR10 Rail, Roof Flush Mounting System - Structural Analysis December 18, 2014 Page 7 of 20 Table 6A - MAXIMUM SPANS (in) - Roof Slope 7' to 27'- Wind Zone 3 (67.5" Max Module Length) XR10 Rail Wind Speed Ground Snow Load Exposure mph 0 psf 10 psf 20 psf 30 psf 40 psf 50 psf 60 psf 70 psf 80 psf 90 psf 100 59 59 55 49 43 39 35 33 31 29 105 56 56 55 49 43 39 35 33 31 29 110 54 54 54 49 43 39 35 33 31 29 120 49 49 49 49 43 39 35 33 31 29 Category B 130 46 46 46 46 43 39 35 33 31 29 140 42 42 42 42 42 39 35 33 31 29 150 40 40 40 40 40 39 35 33 31 29 160 37 37 37 37 37 37 35 33 31 29 170 35 35 35 35 1 35 35 1 35 33 31 1 29 100 50 50 50 49 43 39 1 35 33 31 29 105 48 48 48 48 43 39 35 33 31 29 110 45 45 45 45 43 39 35 33 31 29 120 42 42 42 42 42 39 35 33 31 29 Category C 130 39 39 39 39 39 39 35 33 31 1 29 140 36 36 36 36 36 36 35 33 31 29 150 33 33 33 33 33 33 33 33 31 29 160 31 31 31 31 31 31 31 31 31 29 170 29 29 29 29 29 29 29 29 29 29 100 46 46 46 46 43 39 35 33 31 29 105 44 44 44 44 43 39 35 33 31 29 110 42 42 42 42 42 39 35 33 31 29 120 38 38 38 38 38 38 35 33 31 29 Category D 130 35 35 35 35 35 35 35 33 31 29 140 33 33 33 33 33 33 33 33 31 29 150 31 31 31 31 31 31 31 , 31 31 29 160 29 29 29 29 29 29 29 29 29 29 170 27 27 27 27 27 27 27 27 27 27 Notes — see page 20 din9 De�ar+,rn =1. en . _ APR 0 8 20E3 ?E\11EVa'EU FOR CODE COMPLIANCE Reviewed By �!= Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers -6- -7- IronRidge December 18, 2014 Mr. David F. Taggart Page 20 of 20 IronRidge XR 10 Rail, Roof Flush Mounting System — Structural Analysis Notes — Tabulated values are based on the following criteria: 1. Building mean roof height = 30 ft 2. Risk Category I 3. Solar maximum module long dimension is 67.5 inches for Tables lA-9A and 78.5 inches for Tables 1 B-9B. 4. Provide 2 in. clear between roof and rail 5. End cantilever span (max) = 0.40 x maximum span from above tables 6. No rail splices in end spans 7. No rail splices in middle 1/3 of interior spans 8. Single simple span(s). Spans listed in the tables above may be multiplied by 1.08 for continuous rails of 3 or more spans. Our analysis assumes that the rails, including the connections and associated hardware, are installed in a workmanlike manner in accordance with the "IronRidge Roof Mount Installation Manual' by IronRidge and generally accepted standards of construction practice. Additional information is available at the IronRidge web site, IronRidge.com. Verification of PV Module capacity to support the loads associated with the given array shall be the responsibility of the Contractor or Owner and not IronRidge or Starling Madison Lofquist. The adequacy of the supporting roof framing is to be determined by others. Please feel free to contact me at your convenience if you have any questions. Respectfully yours, Tres Warner, P.E. Design Division Manager Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers -20- err' ~� wilding Department :i 8431 Murphy Drive ,- �� Middleton, WI 53562 USA ..._ APR 0 8 20.8 Telephone: 608.836.4400 REVVEV'iEL FOR CODE l;U!ViPLi,1NCE Facsimile: 608.831.9279 / vvvvw. Intertek. com Test Very IjQwe f - bhfform i In the basis of the tests undertaken, the sample(s) of the below product have been found to comply with the requirements of the referenced specifications at the time the tests were carried out. /Applicant Name & Address: Product Description: Ratings & Principle Characteristics: IronRidge, Inc. 1495 Zephyr Ave. Hayward, CA 94544 USA XR Rails with Integrated Grounding. Fire Class Resistance Rating: -Flush Mount (Symmetrical). Class A Fire Rated for Low Slope applications when using Type 1, 2 and 3, listed photovoltaic modules. Class A Fire Rated for Steep Slope applications with Type1, 2 and 3, listed photovoltaic modules. Tested with a 5" gap (distance between the bottom the module frame and the roof covering), per the standard this system can be installed at any gap allowed by the manufacturers installation instructions. No perimeter guarding is required. Models: 151-61GD-005, 51-61GD-005B, 51-5000-001 and 51-65-001 Brand Name: Relevant Standards Verification Issuing Office: IronRidge Roof Mount UL 2703 (Section 15.2 and 15.3) Standard for Safety Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat -Plate Photovoltaic Modules and Panels, First Edition dated Jan. 28, 2015 Referencing UL1703 Third Edition dated Nov. 18, 2014, (Section 31.2) Standard for Safety for Flat -Plate Photovoltaic Modules and Panels. Intertek Testing Services NA, Inc. 8431 Murphy Drive Middleton, WI 53562 Date of Tests: 08/27/2014 to 03/17/2015 Test Report Number(s): 101769343MID-001r1, 101769343MID-001a, 101915978MID-001 & 101999492MID-001arl-cr1. This verification is part of the full test report(s) and should be read in conjunction with them. This report does not automatically imply product certification. Completed by: Chad Naggs Title: Technician II, Fire Resistance /v/ ,, Signature: rj Date: 03/30/2015 Reviewed by: Gregory Allen Title: Engineering Team Lead, Fire Resistance Signature: Date: 03/30/2015 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sole or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification ore relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. GFT-OP-11a (24-MAR-2014) UUHERTINO } "= Building Dena I-tment s AP? 0 f, 2016 E-Mount Lag I QMSE - LAG 9.00 _ 2.25 ITEM NO. DESCRIPTION QTY./BOX 1 FLASHING, 9" X 12" X .040", 5052, MILL 1 2 QBLOCK, CLASSIC, A360.1 CAST AL, MILL 1 3 PLUG, SEALING, 5/16" X 7/8", EPDM / 18-8 SS 1 4 LAG SCREW, HEX HEAD, 5/16" x 5-1/2", 18-8 SS 1 5 WASHER, FENDER, 5/16" ID X 1-1 /4" OD, 18-8 SS 1 Quick Mount PY` TITLE: QMSE-LAG: QMPV E-MOUNT AVAILABLE IN MILL, AND WITH LAG BOLT BRONZE ANODIZED FINISHES PEOHETAETANDCOMNDEI ML THE INFORMATION COWANED N THE DRAWING D THE SOLE PROPERTY OF QUICK MOUNT PV, ANYREPRODUCTIONINO TORAS A WHOLE WITHOUT ME WRITTEN PERM6SION Of QUICK MOUNT PV 5 PROHIBITED. 5 4 UNLESS OTHERWISE SPECIFIED: SIZE DRAWN BY: DFM REV DIMENSIONS ARE IN INCHES TOLERANCES: FRACTIONAL! I/8 A DATE: 8/29/2014 - DO NOT SCALE DRAWING TWO PLACE DECIMAL 1.18 THREE PLACE DECIMAL 1.125 SCALE: 1:3 WEIGHT:0.96 SHEET OF 3 2 1 Lag pull-out (withdrawal) capacities (Ibs) in typical lumber: Lag Bolt Specifications Specific Gravity 5/16" shaft per 3" thread depth 5/16" shaft per 1" thread depth Douglas Fir, Larch .50 798 266 Douglas Fir, South .46 705 235 Engelmann Spruce, Lodgepole Pine (MSR 1650 f & higher) 46 705 235 Hem, Fir .43 636 212 Hem, Fir (North) .46 705 235 Southern Pine .55 921 307 Spruce, Pine, Fir 42 615 205 Spruce, Pine, Fir (E of 2 million psi and higher grades of MSR and MEL) 50 798 266 Sources: American Wood Council, NDS 2005,Table 11.2 A, 11.3.2 A Notes: 1) Thread must be embedded in a rafter or other structural roof member. 2) See NDS Table 11.5.1C for required edge distances. Quick Mount PV, RESPECT THE ROOF E-Mount Lag Installation Instructions /'`'� �� 0R C 0DE COMPLIANCE Ct �# � / Installation Tools Required: tape measure, roofing bar, chalk line, stud finder, caulking gur%'sP�a ii` npatibl6with r" of`irr�:�rt,%% aterials, drill with 7/32" long -style bit, drill or impact gun with 1/2" socket. Locate, choose, and mark centers of rafters to be Carefully lift composition roof shingle with roofing Insert flashing between 1 st and 2nd course. Slide mounted. Select the courses of shingles where bar, just above placement of mount. Remove nails up so top edge of flashing is at least 3/4" higher mounts will be placed. as required. See "Proper Flashing Placement" on than the drip edge of the 3rd course and lower next page. flashing edge is above the drip edge of 1 st course. Mark center for drilling. �s Using drill with 7/32" bit, drill pilot hole into roof Clean off any sawdust, and fill hole with sealant Slide the flashing into position. Insert the rubber and rafter, taking care to drill square to the roof. compatible with roofing materials. plug into the QBlockcavity. Do not use mount as a drill guide. Drill should be 'long style bit, aka'aircraft extension bit'to drill a 13/4" deep hole into rafter. Slide the washer and the L-foot (not included) onto Using a 1/2 inch socket on an impact gun drive the lag screw. the lag screw until the QBIock stops rotating easily. DO NOT over -torque. BI 7.2.3-31 Sep-2014, Rev 1 BI 7.2.3-31 Sep-2014, Rev 1 Locus ENERGY Product Datasheet The LGate 120 combines a revenue -grade, solid-state power meter with an advanced communications gateway. These components work in conjunction to remotely monitor the performance of residential solar energy installation regardless of panel or inverter type. The LGate 120 is a one-piece completely under glass meter which installs easily using a standard socket base. Performance data is uploaded in near real-time to the Locus Energy SolarOS monitoring platform which provides a suite of tools and analytics for asset managers. DATA COLLECTION AC energy data is collected by the meter and passed to the communications module. Additional system performance data can be collected directly from meteorological sensors and supported inverters via available RS-485 or Zigbee connections. All data is stored in non-volatile memory and then automatically uploaded to the SolarOS and SolarNOC platforms. NETWORK CONNECTIVITY The communications gateway inside the LGate 120 supports plug and play connectivity through a cellular or available Ethernet network connection. Once the unit is installed and powered on, it will immediately begin transmitting data without any configuration. For maximum reliability, the communications gateway will automatically route uploads between the wireless and wired connections if either of the networks are unavailable. FEATURES • ANSI C12.20 power meter • Easy, low cost installation • RS-485 and Zigbee inputs • Doesn't require entrance into the building • GSM cellular or Ethernet connectivity • Plug and play activation • Over the air firmware updates • LCD display DIAGRAM - TYPICAL CONFIGURATION Shielded CATS INTERNET ELECTRICAL ANO �� ;��� -." -fix SERVICE INVERTER(S) LGATE 120 �g Departnent DIMENSIONS PV ARRAY METER BASE u SPECIFICATIONS LOCUS ENERGY COMM MODULE Processor ARM9 embedded CPU OS Custom version of Linux 2.6, OTA firmware updates Memory 128 MB RAM Display LCD screen Enclosure NEMA 3R Type Weight 8 oz Dimensions 6.95" x 6.5" x 7.3" Environment -20 to 60C, all-weather Warranty 5 year limited warranty Model Number OPTIONSCOMMUNICATION INTERFACE LGatel20-3Gx LGatel20-3Gy LGate120-3Gz Cellular - 3G GSM ✓ ✓ ✓ RS-485 2 and 4 wire ✓ Modbus ✓ Zigbee ✓ Ethernet RJ-4510/100, DHCP/Static ✓ METER MODULE U Accuracy Voltage Inputs Max. Current Input Service Type Socket Type t-ji` CODE COMPLIANCE 6.95 in ° 6.31 in l ° 5.46 in --► 6.00 in �— 7.30 in �. ANSI 12.20 (Class 0.2%) 120 - 480 VAC 200 A Single phase , 60 Hz 2S ANSI 12.20 class 0.2% FCC Part 15B PTCRB AT&T Carrier Compliance Single Meter Sockets -Without Bypass 125 & 200 Amp Oil (closed) U204 (open) Application • Single meter position • Receive ANS! C12.10 watthour meters • Surface or flush mount (see chart) Construction • Ring type • NEMAType 3R U� • ANSI 61 gray E-coat finish • Aluminum snap ring included Standards Accessories • UL 414 Listed • 5th Jaw Kit - 50365 • ANSI C12.7 • 200ATriplex Ground - ET6200 • AW Hub Part/UPC Catalog Amp Service Connections Number Number Rating Jaws Type Access Line Load Neutral 78205142000 011 125 4 10/3W OH/UG #14 - 2/0 #14 - 2/0 #14 - 2/0 78205142040 011 F 125 4 10/3W OH/UG #14 - 2/0 #14 - 2/0 #14 - 2/0 78205142045 011 MS73 125 4 10/3W 0H/UG #14 - 2/0 #14 - 2/0 #14 - 2/0 78205142050 011 SF 125 4 10/3W OH/UG #14 - 2/0 #14 - 2/0 #14 - 2/0 78205144030 927 100 7 30/4W OH/UG #14 -1/0 #14 -1/0 #14 - 2/0 78205156000 204 200 4 10/3W OH #6 - 250MCM #6 - 250MCM #6 - 350MCM 78205156020 204 F 200 4 10/3W OH #6 - 250MCM #6 - 250MCM #6 - 350MCM 78205156030 204 F MS73 200 4 10/3W OH #6 - 250MCM #6 - 250MCM #6 - 350MCM 78205156040 204 MS68 200 4 10/3W OH #6 - 250MCM #6 - 250MCM #6 - 350MCM 78205156035 204 MS68A 200 4 10/3W OH #6 - 250MCM #6 - 250MCM #6 - 350MCM 78205108490 204 MS73 200 4 10/3W OH #6 - 250MCM #6 - 250MCM #6 - 350MCM 78205156005 U204 200 4 10/3W UG #6 - 250MCM #6 - 250MCM #6 - 350MCM 78205156045 U204 F 200 4 10/3W UG #6 - 250MCM #6 - 250MCM #6 - 350MCM 78205156060 U204 F MS73 200 4 10/3W UG #6 - 250MCM #6 - 250MCM #6 - 350MCM 78205156070 U204 MS73 200 4 10/3W UG #6 - 250MCM #6 - 250MCM #6 - 350MCM 78205156140 U207 200 7 30/4W OH/UG #6 - 250MCM #6 - 250MCM #6 - 250MCM 78205156170 U207 F 200 7 30/4W UG #6 - 250MCM #6 - 250MCM #6 - 250MCM 78205156180 U207 MS73 200 7 30/4W OH/UG #6 - 250MCM #6 - 250MCM #6 - 250MCM Single Meter Sockets -Without Bypass O11 F - Flush Mount (U) 204 MS68 - 2" Conduit Hub (U) 207 MS68A - MS73 + MS68 927 MS73 - AL Screw Type Ring SF - Semi Flush Mount SS - Stainless Steel Part/UPC Catalog Overall Dimensions Top Knockout Number Number Height Width Depth Provision Layout 78205142000 011 12" 8" 45/e" AW Hub Fig. 1 w` 78205142040 011 F 12" 8" 45/a" 2" max KO Fig. 1 �i 78205142045 011 MS73 12" 8" 45/8" AW Hub Fig. 1 �v� Oep2t� 78205142050 011 SF 12" 8" 45/e" 2" max KO Fig. 1 a�t1t� 78205144030 927 17" 8" 45/e" AW Hub Fig. 1 'V�\ 78205156000 204 15" 8" 45/8" AW Hub Fig. 2 78205156020 204 F 15" 8" 6" 2" max KO Fig. 2 AQ�J 78205156030 204 F MS73 15" 8" 6" 2" max KO Fig. 2 �; P GOO 05 204 MS68 15" 8" 45/e' AW / 2" Hub Fig. 2 7820515603204 MS68A 15" 8" 4 /e AW / 2" Hub Fig. 2,.. E !� 78205108490 204 MS73 15" 8" 45/8" None Fig. 2` 78205156005 U204 15" 12" 45/8" None Fig. 3 eJ�gW 78205156045 U204 F 15" 12" 6" (2) 2" max KO Fig. 3 78205156060 U204 F MS73 15" 12" 6" None Fig. 3 78205156070 U204 MS73 15" 12" 45/8" None Fig. 3 78205156140 L1207 18" 12" 5" AW Hub Fig. 4 AIC Note: 78205156170 U207 F 18" 12" 5" 21/2" max KO Fig. 4 For short circuit current 78205156180 U207 MS73 18" 12" 5" AW Hub Fig. 4 ratings see page 131. Knockout Layouts Fig. Top Provision 4F 4F t oth sides jo1 A Fig. 3 ��- Top Provision 41 O 4G 4F both lbo sides . O 4G 1W 125 & 200 Amp 1 W = t/4' 1 A = 1/2" 2A = 1/2' - 1/4' 4F=2"-11/2'-11/4'-1' 4G=2V2'-2"-1'/2'-11/4' Top Provision = See Chart Fig. 2 Top Provision 0 4F both sides 4F 1-0 1A Fig. 4 - Top Provision 0 4G 4G 4G oG th sides 2A B—Line Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. 5 Meter Mounting Equipment Meter Mounting Equipment 6 B-Line by FA-N ENERGY October 22"d, 2013 This letter is to certify that the LGate 120 and LGate 320 are communication boards built into the Vision Meter 2S CL200 and 16S CL320 socket meters, respectively. Each of these meters was certified to the ANSI C12.20 (class 0.2%) standard by Underwriters Laboratory on June 7, 2013 as part of the Vision Meter Family (Project Number 12CA71134, Job Number 1001541515, and Report Number R12CA71134- ANSI). ANSI C12.20 is currently recognized as the industry standard for electrical socket meters in both utility and PV monitoring applications. These tests cover both meter accuracy as well as several safety standards including electrical and environmental safety, as well as resistance to various types of mechanical shock. As electrical socket meters are generally installed and maintained by trained and certified professionals, rather than consumers, they do not fit the typical criteria for additional types of UL or IEC certification. If you have any further questions regarding the product certification of any Locus Energy LGate-branded device, please contact us at support@ locusenergy.com. The Locus Energy Team r-�UPERTINO �r. 30ding neoartment gyp. _r APR 0 2016 REVIEW--D OR CODE COMPLIANCE ;reviewed 6y Locus Energy, LLC www.locusenergy.com Classic Conduit Composition Mount I QMCC 12.0 J9� i PROPRIETARY AND CONFINKIAL ME INFORMATION CONTAINED N THN DRAW G D THE SOLE PROPIERY OF QUICK MOIMT PV, ANY REPRODUCTION N PART OR AS A WHOLE WITHOUT NE WRMEN PERMDSION OF DUCK MOUNT PV N PROHMED 5 4 ITEM NO. I DESCRIPTION QTY. 1 FLASHING, 9" X 12" X .040", 5052, MILL 1 2 QBLOCK, CONDUIT, 5/16", 6061-T6, MILL 1 3 WASHER, SEALING, 1/4" ID X 7/8" OD, EPDM BONDED SS 1 4 LAG SCREW, HEX HEAD, 1/4" x 2-1/2", 18-8SS 1 AVAILABLE IN MILL, CLEAR ANODIZED, AND BRONZE ANODIZED FINISHES. QUICK mounT ry TITLE: QMCC: CLASSIC CONDUIT COMPOSITION MOUNT UNLESS OTHERWISE SPECIFIED: SIZE DRAWN BY: RAID REV DIMENSIONS ARE IN INCHES TOLERANCES: FRACTIONAL! I/8 A DATE: 9/24/2013 4 - - DO NOT SCALE DRAWING TWO PUCE DECIMAL 1.18 THREE PLACE DECIMAL l.125 SCALE: 1.3 WEIGHT:0.68 SHEET I OF 1 3 2 1 Lag pull-out (withdrawal) capacities Obs) in typical lumber: Lag Bolt Specifications Specific Gravity 1/4" shaft per 1 3/4" thread depth 1/4" shaft per 1" thread depth Douglas Fir, Larch .50 393 225 Douglas Fir, South .46 353 202 Engelmann Spruce, Lodgepole Pine (MSR 1650 f & higher) .46 353 202 Hem, Fir .43 313 179 Hem, Fir (North) .46 353 202 Southern Pine .55 455 260 Spruce, Pine, Fir .42 302 173 Spruce, Pine, Fir (E of 2 million psi and higher grades of MSR and MEL) .50 393 225 Sources: American Wood Council, NDS 2005, Table 11.2 A, 11.3.2 A Notes: 1) Thread must be embedded in a rafter or other structural roof member. 2) See IBC for required edge distances. IMPORTANT. To maintain waterproofing it is important that the aluminum flashing (item 1) is properly placed under one full course above the mounting block with at least some of the flashing extending up under the course above that ac well CPa Inctrl Irtinnc nn hark Quick Mount PV RESPECT THE ROOF BI 7.2.3-8 Aug-2014, Rev 4 Classic Conduit Mounting Instructions Installation Tools Required: tape measure, roofing bar, chalk line, stud finder, caulking gun, 1 tube of appropriate sealant, drill with 1/8" bit, drill or impact gun with 7/16" deep socket. Choose placement of conduit mounts along path Lift composition roof tile with roofing bar, just Slide conduit mount into desired position. Remove of conduit. Select location over center of rafter. above placement of conduit mount. any nails that conflict with getting the mount flush with front edge of shingle course. Mark cernter for drilling. Using drill with 1/8" long bit, drill pilot hole into roof and rafter, taking care to drill square to the roof. Clean off any sawdust, and fill hole with roof Lift shingle and slide conduit mount into place. manufacturer's approved sealant. Prepare lag bolt with sealing washer and single hole clamp (not included) as shown. Insert lag through hole in block, and position clamp over conduit. '�°` "'UPERTINO Uildin De Dan`ent.m r: APR 0 8 2016 REVIEvvL i;/ r-OR CODE COMPLIANCE kev±ewed By C . Insert lag through hole in block, and position clamp over conduit. Using drill with 7/16" socket, drive lag until block is tight. Quick Mount PV 925-478-8269 • www.quickmountpv.com • info@quickmountpv.com BI 7.2.3-8 2700 Mitchell Dr., Bldg 2 • Walnut Creek, CA 94598 Aug-2014, Rev 4 ©2013 by Quick Mount PV. All rights reserved. +CUPERTIN IRAMA PURPOSE SMOKE / CARBON MONOXIDE ALARMS OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • buildino(ftupertino.org FILE s"x"rt "P�abnTt±T'P nr:ri: j This affidavit is a self -certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R314, 2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single-family and multi -family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds $1000.00; CRC Section R314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations: AREA SMOKE ALARM CO- ALARM Outside of each separate sleeping area in the immediate vicinity of the bedroom(s) X X On every level of a dwelling,unit including basernents X X Within each sleeping, roorn X Carbon Monoxide alarms are not required in dwellings which do not contain fuel -bunting appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke: alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. Power Supply: In dwelling units with no. commercial power supply, alarm(s) may be solely battery operated. In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do - not result in the removal of wall and ceilnng finishes or there is no access by means: of attic, basement or crawl space. Refer to CRC Section R3.14 and CBC Sections 907.2.11.4 and 420.6.2. An electrical permit is required for alarms which must be connected to the building wiring. As owner, of the above -referenced property„ 1 hereby certify that the alarm(s); installed in accordance with the manufacturer's- instructions and in complian and California Residential. Codes. The alarms have been tested and are opera below. above has/have been with the California Building nal, as of the date signed Lo Owner Name WATER -CONSERVING PLUMBING FIXTURES OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 • FAX (408) 777-3333 • building(a?cupertino.org 4 1. Is your real property a registered historical site? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. X No Go to Question 2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its plumbing, installation of water -conserving plumbing fixtures is not technically feasible? ❑ Yes Civil Code Sections 1101..1 through 1101.8 do not apply. ❑ The licensed plumber's certification has been provided to the Building Division. Skip the rest of the form and sign bottom of form. No Go to Question 3. 3. Is water service permanently disconnected for your building? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. 1�` No Go to Question 4. Is your real property built and available for use or occupancy on or before -January 1, 1994? ❑ No My real property is built and available for use or occupancy after January 1, 1994. Civil Code Sections 1101.1 through_ 1101.8 do not apply. Skip the rest of the form and sign bottom of form. 1� Yes My real property is built and available for use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101.8 apply. Check one of the three following statements and sign bottom of form.. 5. Please check ONE of the following: N My property is a single-family residential real property. See Civil Code Section 1101.4. On and after January 1, 2014, building alterations or improvements shall require all non -compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures throughout the building. On or before January .1, 2017, all non- compliant plumbing, fixtures shall be replaced with water -conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements). ❑ My property is a multifamily residential real property: See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non -compliant plumbing fixtures shall be replaced with water - conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). ❑ My property is a commercial real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non -compliant plumbing fixtures shall be replaced with water conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). I, as the owner or owner's agent of this property, certify under penalty of perjury that non -compliant plumbing fixtures will be replaced prior to date specified above with water -conserving plumbing fixtures in accordance with Civil Code Sections 1101.1 through 1101.8, the current California Plumb' ode and California Green Building Standards Code, and manufacturer's installation requirements, and that the wat -co ing plumbing f- comply with the requirements as indicated in the table on the followingpage.. 1 Owner or Owner Agent's Signature. &- - Date:._-, � Upon completing and signing this Certificate, please , eturn ityto the Building Division in order to final yo r building permit. P SB407 2015.doc revised 08126115