Loading...
15060181Mal CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOM PERMIT NO: 15060181 21331 COLUMBUS AVE CUPERTINO CA 95014 (362 04 002) ( AAA CONSTRUCTION SERVICES) CAMPBELL, CA 95011- 0971 OWNER'S NAME: BHASKAR SREEKANTH AND SREEKANTH BAN DATE ISSUED: 12/09/2015 OWNER'S PRONE: PHONE NO: LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO: License Class Lie. At�' Contractor (A A A CONSTRUCTION SERVICES Date i� —BLDG _ ELECT PLUMB MECH RESIDENTIAL COMMERCIAL , I hereby affirm that I atm licensed under the provisions of Chapter 9 (commencing — — — with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. J611 DESCRIPTION: ADD 703 S.F TO SFD & CONVERT GARAGE (143 S.F.) TO I hereby affirm under penalty of perjury one of the following two declarations:. RECONFIGURE KITCHEN & FAMILY RM, ADD (N) MASTER r. I have and will maintain a certificate of consent to self -insure for Worker's SUITE, 2 (N) BAY WINDOWS, 112 BATH & FOYER. UPDATE Compensation, as provided for by Section 3700 of the Labor Code, for the & REMODEL OTHER AREA 774 S.F. ADD 69 S.F. PORCH performance of the work for which this permit is issued. 2. I have and will maintain Worker's. Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which Sq. Ft Floor Area: Valuation: $175000.00 this permit is issued. APPLICANT CERTi", CATION I certify that I have read this application and state that the above APN Number: Occupancy Type: Information Is correct. I agree to comply with all city and county 36204002 ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and PERMIT EXPIRES IF WORK IS NOT STARTED expenses which may accrue against sold City in consequence of the WITHIN 184 DAYS OF PERMIT ISSUANCE OR granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal j$a A T ECTION. Code, Section 9.18. �— - SignatulDate f��� Issued ate: E O@VNER-BUILDER DECLARATION R R�rS. I hereby affirm that I am exempt from the Contractor's License Law for one of the Ali roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for following two reasons: a. I, as owner of the property, or my employees with wages as their sole inspection. compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) Signature ofAppticant: a. I, as owner of the property, am exclusively contracting with licensed Date: contractors to construct the project(See,7044, Business & Professions Code), ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER I hereby affirm tinder penalty of perjury one of the following three declarations: 1. I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the HAZARDOUS MATERIALS DISCLOSURE performance of the work for which this permit is issued. I have read the hazardous materials requirements tinder Chapter 6,95 of the 2. 1 have and will maintain Worker's Compensation Insurance, as provided for California Health & Safety Code, Sections 25505, 25533, and 25534. I will by Section 3700 of Clic Labor Code, for the performance of the work for which maintain compliance with the Cupertino Municipal Code, Chapter 9,12 and the Health & Safety Code, Section 25532(a) should (store or handle hazardous this permit is issued. material. Additionally, should I use equipment or devices which emit hazardous 3. 1 certify that in the performance of the work for which this permit is issued, I air contaminants defined District I the Bay Area Air Quality ManagementdChapter shall not employ any person in any manner so as to become subject to the �i211 maintain compliance with the Cupertino Municipal Code, Clingier 9.12 Arid p h Worker's Compensation laws of California. if, after making this certificate of tiro Health & Safety Code, Sections 25505, 25533, and 25534. exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I rust forthwith comply with such provisions or this permit shall �. Owner r a t oNzed [ent' .. . be deemed revoked. Dat�fi% C ONSTRUC I IOrI LENDING AGT Nt Y APPLICANT CERTIFiCATION I certify that t have read this application and state that the above information is I hereby affirm that there is a construction lending agency for the performance of work's for which this permit is issued (Sec. 3097, Civ C.) correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city Lender's Name to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, Lender's Address judgments, costs, and expenses which may accrue against said City in ARCHITECT'S DECLARATTON consequence of the granting of this permit. Additionally, the applicant beT used a E understand my plans shall be used as public records. understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Licensed Professional Signature Date of � �ot rban wv)ocgrv.kw t-� mo Ijd xo- J --,b A-raq-trr A -0_ 0.d Ckt AO n V?P rn'C)4Q.LP Aj &%rpt S kwL) J -b tfjQ C.o 1) yr res tie. Qj,,DMA c t\Jcxm,e Con tr) � O coo. LtLrA�r�ino 36013 I CITY OF CUPERTINO BUILDING PERMIT I I BUILDING ADDRESS: 21331 COLUMBUS AVE AND SREEK ONTH BAN SREEKANTH I PERMIT NO: 15060181 I OWNER'S NAME: BHASKAR SREEKANTH AND SREEKANTH BAN OWNER'S PHONE: 6502793750 ri LICENSED CONTRACTOR'S DECLARATION License Class Lic. # Contractor Date I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business. & Professions Code and that my license is in full force and effect.' I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section' 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Signature Date OWNER -BUILDER DECLARATION. I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.7044, Business & Professions Code). I hereby affirm under penalty of perjury one of the following three declarations: I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I 21331 COLUMBUS AVE I DATE ISSUED: 12/09/2015 CUPERTINO, CA 95014-4921 1 PHONE NO: JOB DESCRIPTION: RESIDENTIAL E] COMMERCIAL M ADD 703 S.F TO SFD & CONVERT GARAGE (143 S.F.) TO RECONFIGURE KITCHEN & FAMILY RM, ADD (N) MASTER SUITE, 2 (N), SAY WINDOWS, 1/2 BATH & FOYER. UPDATE Sq. Ft Floor Area: I Valuation:. $175000 APN Number: 36204002.00 1 Occupancy Type: PERMIT EXPIRES IF WORK IS NOT STARTED WITHIN 180 DAYS OF PERMIT ISSUANCE OR 180 DAYS FROM LAST CALLED INSPECTION. Issued by: Date: RE -ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. Signature of Applicant:. Date: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER HAZARDOUS MATERIALS DISCLOSURE I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Sections �2505, 2 33, and 25534. *� Owner or authorized agent: Dater ` CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code, I must I I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source r ulations per Cupertino Municipal Code, Section 9.18. pp t n_._ 10_>�nC�l\10 It Lender's Address ARCHITECT'S DECLARATION I understand my plans shall be used as public records. Licensed Professional CONSTRUCTION IT APPLICATION 2 COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 10300 TORRE AVENUE a CUPERTINO, CA 95014-3255 (408) 777-3228 a FAX (408) 777-3333 e buila�dii cuperlino oCUPERTINOrq A� a / M NEW CONSTRUCTION n ADDITION n ALTERATION / TI n REVISION / DEFERR.EI D ORIGINAL PERMIT # PROTECT ADDRESS �g pQ _ C APN # % '7 /'I C/. ✓ 00 A��.,,i,,'rfe�- q gJ_ �o^r� gk OWNER NAME c, R C-E� K ft1\ t F � dr) t I _S \ rri'°i COMPANY NAME PHONF 650 -2,q J-3'�`'i'i_ 1 `✓CU E-MAIL 6 & L 9 rnOl L- �6 STREET ADDRESS 9- 1 3 a I C -c L Liaa nn�� �rr � 4v CITY, STATE> ZIP p' E( k( I v= () t FAX p��e-��u CONTACT NAME � " )A1 1 H- t .. _ DEscxlPlloN of WORK . , r , % P% 170r E-MAIL r �f�- STREETADDRESS 21 381 (_Q Lt. M a) V._'. � CITY, STATE, ZIP Ct�1'PE 1rr �^/�� l� FAX 1:1 OWNER 0 OWNER -BUILDER 13 OWNER AGENT ❑ CONTRACTOR ❑ CONTRACTOR AGENT 13 ARCHITECT ❑ ENGINEER 13 DEVELOPER 13 TENANT CONTRACTORNAME r— LICENSE NUMBER LICENSE TYPE BUS. LIC # COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE ARCHITECT/ENGINEER NAMF, ZEptVA J"D SF LICENSE NUMBER BUS. LIC # FAX .Zo9 - OS' �Z. COMPANY NAME E-MAIL J Ze k'dac ca t, 4I b(Z&O STREET ADDRESS / rw (_ SECOND STORY CITY, STATE> ZIP L"rT 53301. PHONE 62 9 , 6 -ty, DEscxlPlloN of WORK . , r , % r P ,I 1- _ A —ii � . , _, 6 & A a EXISTG NEW FLOOR DEM AREA ARE, _9 AT BATHROOM KITCHEN REMODEL. AREA REMODEL AREA I TOTAL NET AREA 1 OTHER i xEMODEL ART_ E �9IWO # DWELLING UNITS: IS A SECOND UNIT 0 YES SECOND STORY BEINGADDED? ONO ADDITION? PR&APPLICATION ❑ YEs IF YES, PROVIDE COPY OF IS THE BLDG AN PLANNINGAPPL# ONO PLANNING APPROVAL LETTER EICHLERHOME? By my signature below, I certify to each of following: I am the property application and the inform I have p vided is correct. I have re.a e D ordinances and state law re f g to b Idin construction. or Signature of Applicant/Age USE I TYPE I OCC. I SQTT. V VALUATION (S) owner or authorized age n the property owner's behalf. I have read this ;scri tion of Work and verify it is accurate. I agree to comply with all applicable local A;�! ertino to enter the above-identifiedd property for inspection purposes. Date: 04- 1 _ 6 12 F% SUPPLENUKAL H4•O9MA•11UN K�_`7UIKtIJ PLANCHECKTYPE; _ New SFD or Multifamily dwellings: Apply for demolition permit for 11OVER.THE-COUNTEIR existing building(s). Demolition permit is required prior to issuance of building permit for new building. 0 EXPRESS _ Commercial Bldgs: Provide a completed Hazardous Materials Disclosure ❑ sTArmAxa form if any Hazardous Materials are being used as part of this project. 0' LxR _ Copy of Planning Approval Letter or Meeting with Planning prior to 01 MAJOR submittal of Building Permit application. O IILPING PLAN REVIEW 0 PLAN NINGPLANREVIEW n PUBLIC WORKS CI FiRF DEPT SAWARY SEWERD19TRICT Bldgvlpp_201 1. doc revised 06121111 CITY OF CUPERTINO FFF ESTIMATOR - R1TI11,I1INV_'nIVl1,Q1nN 21331 COLUMBUS AVE DATE: 06126/2015 REVIEWED BY: MELISSA JimADDRESS: APN: 362 04 002 BP#: *VALUATION: 1$175,000 'PERMIT TYPE: Building Permit PLAN CHECK TYPE: Addition PRIMARY SFD or Duplex USE: -? Unit? 0 Yes (F) No OTC OTC? 0 Yes 0 No ENTAMATION PERMIT TYPE: 1R3SFDADD WORK ADD 703 S.F TO SFD & CONVERT GARAGE (143 S.F. TO RECONFIGURE KITCHEN & FAMILY SCOPE RM, ADD (N) MASTER SUITE, 2 (N) BAY WINDOWS, 1/2 BATH & FOYER. UPDATE & REMODEL OCCUPANCY TYPE: TYPE OF CONSTR. FLR AREA (S-0 PC FEES PC FEE ID BP FEES BP FEE ID R-3 (Custom) A 11-8,111-B,1V,V-B 965 $2,654.00 JR3PLNCK $1,666.00 IR31NSP PME Plan Check: $0.00 Permit Fee: $1,666.00 Suppl. Insp. Fee -0 Reg. 0 OT�hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 ConstructionTax: TOTALS: 965 $2,654.00 v $1,666.00 -1,fech. I'lart ('heck Mech. Peprnhl Fee: Other -Ikxh. Insp. Plumb. 11kin Check Plumb, Peonii Fee: Other Plumb lrtspn Elec,.P/an Check Islet. Permit F4;e: Other Elec. Imp, Ilech. Imp, Fee: I fllwnb. hisp . Fee: I Elec. IPK,;P NOTE: This estimate dnow not inelazle fees due to athor Donartmontv 4i P_ Planning. Pahlic Works. Fire. Sanitary Sewer District. School rmitart tho Dont fnraddnl info. FEE ITEMS (Fee Resolution 11-053 Eft.' 711113) FEE QTY/FEE MISC ITEMS Plan Check Fee: $2,654.00 774 1 s.f. Remodel, Other $575.001 IREMRESOTH Suppl. PC Fee: (j) Reg. 0 OT 0.0 hrs $0.00 PME Plan Check: $0.00 Permit Fee: $1,666.00 Suppl. Insp. Fee -0 Reg. 0 OT�hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 ConstructionTax: Adinin istrofive F, ee: 0 E) Work Without Permit? 0 Yes (F) No $0.00 Advanced Planning Fee: IPLLONGR $135.10 Select a Non -Residential -1 Building or Structure 0 A Tre,wi,el Documestation 1"ees: Strong Motion Fee: IBSEISMICR $22.75 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $7.00 j SiMT "i" ' $4,484.85 $575.00 $5,059.85] Revised: 05107/2015 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO: 15060181 21331 COLUMBUS AVE CUPERTINO CA 95014 (362 04 002) AAA CONSTRUCTION SERVICES CAMPBELL, CA 95011- 0971 OWNER'S NAME: BHASKAR SREEKANTH AND SREEKANTH BAN I J DATE ISSUED: 12/09/2015 OWNER'S PHONE: 650-279-3750 1 1 PHONE NO: (408) 502-2760 t t IT'yi afi7ll_\mil113go License Class IJ Lic. #984062 Contractor AAA CONSTRUCTION SERVICES Date 06/30/2017 I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: t. 1 have and will maintain a certificate of consent to self -insure for Worker's V,ve pensation, as provided for by Section 3700 of the Labor Code, for the once of the work forwhich thispermitis issued. and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the per of the work for which this permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino MunicipAL C a Saco�. Signature Date 4/14/2016 I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: t. I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) 2. I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.7044, Business & Professions Code). I hereby affirm under penalty of perjury one of the following three declarations: 1. I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. a. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Signature Date 4/14/2016 BUILDING PERMIT INFO: —BLDG —ELECT —PLUMB _ MECH _ RESIDENTIAL _ COMMERCIAL JOB DESCRIPTION: ADD 703 ST TO SFD & CONVERT GARAGE (143 S.F.) TO RECONFIGURE KITCHEN & FAMILY RM, ADD (N) MASTER SUITE, 2 (N) BAY WINDOWS, 1/2 BATH & FOYER. UPDATE & REMODEL OTHER AREA 774 S.F. ADD 69 S.F. PORCH Rev #I - CHANGE KITCHEN WINDOW FROM BAY TO SLIDER, ADD 2X4 SKYLIGHT, ADD SUN TUNNEL IN OFFICE, ELIMINATE SINK IN ISLAND, CHANGE BATH TUB TO SHOWER. ISSUED 4/14/16 Sq. Ft Floor Area: I Valuation: $175000.00 APN Number: Occupancy Type: 362 04 002 PERMIT EXPIRES IF WORK IS NOT STARTED WITHIN 180 DAYS OF PERMIT ISSUANCE OR 180 DAYS FROM LAST CALLED INSPECTION. Issued by: ABBY AYENDE Date: 12/09/2015 RE -ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. Signature of Applicant: Date: 4/14/2016 ALL ROOF COVERINGS TO BE CLASS "A" OR BF] HA4 HAZARDOUS MATERIALS DISCLOSURE I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District 1 will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Sections 2550 25533, and 25534. Owner or authorized agent: Date: 4/14/2016 T �= ENDING AGENCL-----'--- I hereby affirm that there is a cons g agency for the performance of work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name Lender's Address ARCHITECT'S DECLARATION I understand my plans shall be used as public records. Licensed 4 CUPERTINO CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 ��i t (408) 777-3228 • FAX (408) 777-3333 • buildinp(a.cupertino.or4 ❑ NEW CONSTRUCTION ❑ADDITION ❑ ALTERATION / TI VlRiVISION /DEFERRED ORIGINIAL PERMIT n air PROTECT ADDRESS ( APN R 6 I lt,�„l/DuI.�1 � V o.. 0\ NAI✓E � I P _ .�"' E-i`ZAIL '�- STREET. SC1 STATE, ZIP FAX CON NAME O E MAIC', V STREETADDRESS CITY, TATE, ZIP FAa ❑ 01.'NER ❑ OIANTER-BUILDER ❑ 01;'I."ERAGEN°T ❑ CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGA'EER ❑ DE"SLOPER ❑ TENANT CONTIiACTORNAA4 � LICENS_ . T ER LIC ' TYPE BUS.LIC# r1-� COA4PA)\Z'NAE /� E-MAIL FAX STREE •'E S CITY, STATE, ZIP PHONE ARCHITEC NG E ?\`ANE LICENSE NUMBER ^ C 7 A y ^/� J BUS. LIC 4 COb4PAN ' �iE� E-NiAIL FAX 209 S? /-oS4 2 STREET ADDRESS CITY, TATE, ZIP PHONE 821 r CA 9S 209 a _ DESCRIPTION OF WORK �C_�'(/, Caw �.J✓ Y �C'.�..� �� `'uK/\ T— EXISTING USE PROPOSID USE CONSTR. TYPE n STZ5RIES USE TYPE OCC. SQ.FT. I VALiJ.ATIOT: (i) EXISTG NEW FLOOR DEMO TOTAL - AREA I AREA AREA -7 NET AREA FOR I BATHROOM KITCHEN OTHER REMODEL .AREA REMODEL AREA REMODELAREA PORCH AREA DECK AREA TOTAL DEC}:.?ORCH ?.RE4 GARAGE .AREA: LJDETACH -- ❑ ATTACH I I DwELLII.G UNITS: IS A SECOND UNIT ❑YES SECOND STORY E)) 'ES BEING ADDED? ❑ NO ADDITION? ❑ NO PRE -.APPLICATION ❑ YES IF YES, PROVIDE COPY OF IS THE BLDG AN El: -Es IV B1 TOTAL VALUATION: PLANITINGAPPL-, ❑NO PLA?.'NING APPROVAL LETTER EICHLER HOME? ❑NO ;� By my signature below, I certify to each of the fo110wing: property owner or authorized agent t act o the property owner's behalf. I have read this application and the information I have provided i e .ave read the Description of'Work- and verify itis accurate. I agree to comply -x ith all applicable local ordinances and state la-wS relating to buildi vction. I authorize representatives of Cupertino to enter the zb 'e-idenf r5d property. for inspection purposes. Signature of Applicant/Agent:— SUPPLEM L INFORI\4ATION REQtiIR.ED New SFD or Multifamily d}a ellings: Apply for demolition permit for existing building(s). Demolition permit is required prior to issuance of building permit for new building. _ Commercial Bldgs: Provide a completed Hazardous Materials Disclosure _ form. if any Hazardous Materials are being used as part ofthis project. _ Copy of Planning Approval Letter or Meeting with Planning prior to submittal of Building Permit application. Bldg4pp_201 Ldoc revised 06121111 CUPERTINO OWNER -BUILDER DISCLOSURE FORM COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 - FAX (408) 777-3333 • buildinola cuoertino.org Dear Property Owner(s): An application for a building permit has been submitted in your name listing yourself as the builder of the property improvements specified at: SITEADDRESS I3.3I CvLuMC�I qVE_ ....APN.,. OWNER NAME _ _ ER ADDRESS:. A vc DESCRIPTION OF WORK: We are providing you with an Owner -Builder Acknowledgment and Information Verification Form to make you aware of your responsibilities and possible risk you may incur by having this permit issued in your name as the Owner -Builder. We will not issue a building permit until you have read, initialed your understanding of each provision, signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice unless you, the property owner, obtain the prior approval of the permitting authority. OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION (DIRECTIONS: Please read and initial each statement below to signify you understand or verify this information.) SS 1.1 understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner - Builder" building permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as an Owner -Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those icjuries. I am willfully acting as an Owner -Builder and am aware of the limits of my insurance coverage for injQries to workers on my property. cis 2. I understand. building permits are not required to be signed by property owners unless they are responsible for the construction and are not hiring a licensed Contractor to assume this responsibility. 03. 1 understand as an "Owner -Builder" I am the responsible parry of record on the permit. I understand that I may protect myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead of my own. 0 4. 1 understand Contractors are required by law to be licensed and bonded in California and to list their license numbers on permits and contracts. � 5. I understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employer" under state and federal law. SS 6. 1 understand if I am considered an "employer" under state and federal law, I must register with the state and federal government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment compensation for each "employee." I also understand my failure to abide by these laws may subject me to serious financial risk. 9S 7.1 understand under California Contractors' State License Law, an Owner -Builder who builds single-family residential structures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed under contract with a licensed general building Contractor. 9S 8. 1 understand as an Owner -Builder if I sell the property for which this permit is issued, I may be held liable for any financial or personal injuries sustained by any subsequent owner(s) that result from any latent construction defects in the workmanship or materials. OwnerBuilderForm 2010.doc revised 04/19/10 &S 9. 1 understand I may obtain more information regarding my obligations as an "employer" from the Internal Revenue Service, the United States Small Business Administration, the California Department of Benefit Payments, and the California Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1-800-321-CSLB (2752) or www.cslb.ca.gov for more information about licensed contractors. SS 10.1 am aware of and consent to an Owner -Builder building permit applied for in my name, and understand that I am the party legally and financially responsible for proposed construction activity at the site address listed above. Qa11. 1 agree that, as the party legally and financially responsible for this proposed construction activity, I will abide by all applicable laws and requirements that govern Owner -Builders as well as employers. S12. I agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the' information l have -provided on this form. Licensed contractors are regulated by-laws designed to protect .the.. public. If you contract with someone who does not have a license, the Contractors' State License Board may be unable to assist you with any financial loss you may sustain as a. result of a complaint..Your only remedy against unlicensed Contractors may be in civil court. It' is also important for you -to understand that if an unlicensed Contractor or employee of that individual or firm is injured .while working on your property, you may be held liable for damages. If you obtain a permit as Owner -Builder and wish to hire Contractors, you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers' compensation insurance coverage. CONSTRUCTION LENDING AGENCY (DIRECTIONS: Please complete the following construction lending agency information.) I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097 Civ.) Lender Name: Lender Address: Before a building permit can be issued, this form must be completed and signed by the property owner and returned to the agency responsible for issuing the permit. Note: A copy of the property owner's driver's license, form notarization, or other verification acceptable to the city may be required to be presented when the permit is issued to verifli the property owner's si nature. Property Owner's Signature: I Date: r -Lb e wing uthorizat16n- ------------------------------------------For----m---is----------required---to--be---------------completed---by---the------------property----owner------onl---y--when----------designating-----------an---- - (NOTE: ThfolloA agent of the property owner to apply for a construction permit for the Owner -Builder). AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize the following person(s) to act as my agent(s) to apply for, sign, and file the documents necessary to obtain an Owner -Builder Permit for my project. Scope of Construction Project (or Description of Work): Project Location or Address: Name of Authorized Agent: Address of Authorized Agent: Tel No I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above information and certify its accuracy. Note: A copy of the property owner's driver's license, form notarization, or other verification acceptable to the city may be required to be presented when the permit is issued to verify the property owner's signature. Property Owner's Signature: Date: OwnerBuilderForm 2010.doc revised 04/14/10 ALTERNATE MATERIALS AND METHODS / MODIFICATION FORM COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • buildinaacupertino.orta CUPERTINO BP REQUEST FOR MODIFICATION OF CODE (CBC 104.10, CFC 104.8) ❑ REQUEST FOR ALTERNATE MATERIAL, DESIGN OR METHOD OF CONSTRUCTION (CBC 104.11, CFC 104.9) To aooly for this request comoipta ser:tions 1 7 R 3 fink nr tvna) SITEADDRESS 1C,1I �� C��RAVY 05 kY e APN 3 6 Z ^ O4' OO Z DATE 6 _ 7- 20)S /. Owner ..... 5.�!(,e.t.l.a....... u nd..5..t � .Canl h .................. _. .......................... PC #:.. l��. Q. b.Q. � ,/Q Q Type: R.� 1 Address ... �.1..33.J....... 0 .Q..�ISI.?^'�.4? V.,�..... RI.�.-....C.u.�.r I✓lA A. 1 ......)................ ..a.�....... Permit .........Y.. ................... I Email............................................................. Phone ..... ...................................... #:......................... ...... PLN #: ............................... Dept./Div ............................... Stories:...... ................ ..... Occupancy: .... P-Jju. ..... Floor Area:.7-0WA4& ... 3 On ia JJ Applicant.... ,.,�.D..S. .........�.Q .Q aQ.......... Title ............................................... /+" Address .......La.�-1.... �.I..lr. M-�....+.�.X/.F..�'a..... C.�?......�}..�„3�..�......... Job Status: ........................... Occ. Load:.......................... 1 Use of Bldg:..�.C.Si,t! Email....., i.2.� .... • •. ��iw•.... Phone... CZp.9).19..6-.88.1.0.... 2 REQUEST: For code modifications please state the applicable code requirement and the extent of relief desired For alternate requests, state the type of system proposed and design methods. Subrrit plans if necessary to illustrate request Additional sheets or data may be attached. Code Section(s): /Y �1 �, 8/ 1 Z613 1863.1 0-9(— W 1 vE12 04: GEOTEC-40CAL QiEP01V&E4UiU1nE1�Z5 y r i nr 3 JUSTIFICATION/FINDINGS OF EQUIVALENCY: For code modifications, applicant shall demonstrate that special, individual reasons exist that crake compliance with the strict letter of the ordinance impractical and that equivalency is provided. For alternate requests, applicant shall demonstrate suitability. strength, effectiveness. fire resistance. durabili • sale and sanitation that is equivalent to the code for a similar use.— Code Section(s): /Y �1 �, 8/ 1 Z613 1863.1 0-9(— Attach additional sheets if necessary. y r i nr I No. of Items:...:.. .. Fee Due: S ......1 . ............... . Date Paid: ................................ Receipt No .. .............................. Processed by: yy........ ........c.......... Petitioner's/ Signature: ....... Position:..Clll.y....C/1 1�i1 Date:. $ .x .+1 �. Reviewed By: ................................................Date:......................... V/ IV --.A - - / The Request is: GRANTED ❑ DENIED Dept. Comments. CONDITIONS OF APPROVAL: No. of Items:...:.. .. Fee Due: S ......1 . ............... . Date Paid: ................................ Receipt No .. .............................. Processed by: yy........ ........c.......... BuildingOfficial* ..... . ...................................� ...... ...... ..Print: ..........11.V..J1..Y.._. �%% ((�� _ .. Date:..V.. 1........t..✓_...... FireMarshal. ..... ... .......................................................................... Print: .......... ............................................ .......................... Date:.................................. WQIm I MGI\ 1 M%' I IVrm. MIMI UVICl Ih111a11V11, I.UPIV5 [Q. 1) aPp11Gant. Cf perrn11 The AIfform=20lS.doc revised 0!'06.1 S W���,��, CITY OF CUPERTINO - ] FEE ESTIMATOR - BUILDING DIVISION 19' ADDRESS: 21331 Columbus Ave. DATE: 08/12/2015 REVIEWED BY: A. Salvador APN: BP#: 15060181 'VALUATION: Iso XPERMIT TYPE: Building Permit PLAN CHECK TYPE: Addition PRIMARY SFD or Duplex USE: P 0.0 PENTAMATION PERMIT TYPE: 1 GENRES WORK Waiver of Geotechnical Report SCOPE NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School District etc) Thacp fvoc are based nn the nreliminary information available and are onlv an estimate Contact the Dept for addn'l info. FEE ITEMS (Fee Resolution I l -053 1jf, 7/1. 131 Afech. Man ( '. Plzimh. Plan Chech MISC ITEMS /'/((mh. Perwil h r Jec. Permit hire: )ir'te'r ;i- tech. huiz, 11himb hisp. El Suppl. PC Fee: 0 Reg. Q OT 0.0 hrs NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School District etc) Thacp fvoc are based nn the nreliminary information available and are onlv an estimate Contact the Dept for addn'l info. FEE ITEMS (Fee Resolution I l -053 1jf, 7/1. 131 FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 Select a Misc Bldg/Structure or Element of a Building Suppl. PC Fee: 0 Reg. Q OT 0.0 hrs $0.00 PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Fee:Q Reg. Q OT 0.0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 Construe,lion TCA': 4dininistrative Fee.- ee.Work 0 WorkWithout Permit? Yes (F) No $0.00 Advanced Planning Fee: $0.00 Select a Non -Residential Building or Structure 7ruvet Docutrientution I%ses. Strong Motion Fee: $0.00 F 71 # $187.00IALTMAT Alternate Materials and Methods Bldg Stds Commission Fee: $0.00 SUBTOTALS: $0.00 $187.00 TOTAL FEE: $187.00 Revised: 07/02/2015 ALTERNATE MATERIALS AND METHODS / MODIFICATION FORM COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • buildingna cupertino.org ❑EQUEST FOR MODIFICATION OF CODE (CBC 104.10, CFC 104.8) REQUEST FOR ALTERNATE MATERIAL, DESIGN OR METHOD OF CONSTRUCTION (CBC 104.11, CFC 104.9) ❑ REQUEST FOR HARDSHIP EXEMPTION OR EQUIVALENT FACILITATION (HEALTH AND SAFETY CODE 19957) To apply for this request, complete sections 1, 2, & 3 (ink or type) SITE ADDRESS 33/ Gam 1/�i3 ✓5 /� AP DATE Owner... CIC. ........ ...... I. . .. . ....... ............................................. 11 11 11 Address .. ....1.-S ......... Ll1.t�w / ../'�•................................. PC #: Permit #: I�D�op�Bl.. Type:.......... V.`J ............. Stories:............... Email .5..... .. 7.Y.. ................. Ptho. r.4l:. . ........... 4 / In /2'j Reviewed / By: ........ Date:% PLN #: .................................. Dept./Div ............................... Occupancy:........................... Floor Area:............................. //.. Applicant. .(,,F(!: .... C�D'av%�i G4 eTOY� ....................... ......... Title ............................................ ft�-77 �.i6t C&.5. ( Job Status:..1��!//%.... Occ. Load: ............................ EmaiL20 �i,Z i ........ Use of Bldg:...,`� '...... 10-93R? 2 REQUEST: For code modifications, please state the applicable code requirement and the extent of relief desired. For alternate requests, state the type of system proposed and design methods. Submit plans if necessary to illustrate request. Additional sheets or data may be attached. Code Section(s): ZC z d -- ..- CONDITIONS OF APPROVAL: Z \33 In Petitioner's6 Signature: ... ..... .............. Position: .................... ............ Date: !.i ...... ..... 3 JUSTIFICATION/FINDINGS OF EQUIVALENCY: For code modifications, applicant shall demonstrate that special, individual reasons exist that make compliance with the strict letter of the ordinance impractical and that equivalency is provided. For alternate requests, applicant shall demonstrate suitability, strength, effectiveness, fire resistance, durability, safety and sanitation that is equivalent to the code for a similar use. Code Section(s): ZC z d -- Attach additional sheets if necessary. CONDITIONS OF APPROVAL: Petitioner's6 Signature: ... ..... .............. Position: .................... ............ Date: !.i ...... ..... Reviewed / By: ........ Date:% The Request is: ErGRANTED ❑ DENIED I Dept. Comments: CONDITIONS OF APPROVAL: THIS PLAN SHALL REMAIN ON No. of Items:........... .................. Fee Due: $ ...1`7 8... r>e-- ... Date Paid: ................................ No.: .............................. Processed by: ........ ................... THE B AT ALL TIMES DURIN(; CONSReceipt 01 Building Official:..... .. . .. ....��......................Print:......... ....1 .......................... Date: ... /�• l�P FireMarshal: ..................................................................................... Print:..................,.............................................................. Date:.................................. DEPARTMENT ACTION: After determination, copies to: 1) applicant, 2) permit file Altform 2015.doc revised 07101115 ALTERNATE MATERIALS AND METHODS / MODIFICATION FORM COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION I� 10300 TORRE AVENUE • CUPERTINO, CA 9rc3 u (408) 777-3228 •FAX (408) 777-3333 • buildin o FICECUPERTINO Copy ❑EQUEST FOR MODIFICATION OF CODE (CBC 104.10, CFC 104.8) R �.� EQUEST FOR ALTERNATE MATERIAL, DESIGN OR METHOD OF CONSTRUCTION (CBC 104.11, CFC 104.9) ❑ REQUEST FOR HARDSHIP EXEMPTION OR EQUIVALENT FACILITATION (HEALTH AND SAFETY CODE 19957) Tn onnly fnr Chic rcni acct—rnnlctc cartinnc 1 9 R '2 link nr txmol SITE ADDRESS / 33� GGL ���3 �s 1-4APN��� • D y ' DDo� DAT Owner... �i....... ....... .. C ............................................. 11 1` Address.. '. ...1......... j�ll.tv�a.. ............................... P C # Permit �BI Type• V�................. S tories:...........� S, �. �1,i .......JD�o �3 Email. .. �.Y. ............... Pho .... ........... PLN #:.................................. Dept./Div ............................... Occupancy: P y :........................... Floor Area:............................. Applicant. .(..F(!•........................... U.. (,lO�v�lQ �%� .............. Title............................................( Address.a............. bi? . .... 1.1 ` .`7.f.......... �be t[... i4..`� 5� l Job Status: �v'-�sl%.... Occ. Load :............................ (.. .. ......... IoM.... Emaill�.Cpt�.S•�.l.Ceb.T�r�.r��'....... 142 Use of Bldg:...'....... 2 REQUEST: For code modifications, please state the applicable code requirement and the extent of relief desired. For alternate requests, state the type of system roposed and design methods. Submit plans if necessary to illustrate request. Additional sheets or data may be attached. Code Section(s): Attach additional sheets if necessary. CONDITIONS OF APPROVAL: //� f%L,L 3 JUSTIFICATION/FINDINGS OF EQUIVALENCY: For code modifications, applicant shall demonstrate that special, individual reasons exist that make compliance with the strict letter of the ordinance impractical and that equivalency is provided. For alternate requests, applicant shall demonstrate suitability, strength, effectiveness, fire resistance, durability, safety and sanitation that is equivalent to the code for a similar use. Code Section(s): Attach additional sheets if necessary. CONDITIONS OF APPROVAL: //� f%L,L �%C,«Z �/ HC/7�C� GG ' � Cy� "— /6 6 Petitioner's / Reviewed e/ Signature: Position:.. .................... Date: �I .......... By: .......f—�N..(... R�L..Date: The Request is: ErGRANTED 11DENIED Dept. Comments: CONDITIONS OF APPROVAL: //� f%L,L �%C,«Z �/ HC/7�C� GG ' � Cy� "— /6 6 No. of Items:........ . ....... I.......... Fee Due: $ ...yB................ Date Paid: ................................ Receipt No.: .............................. Processed by: ............................ Building Official:. ... .. `/....................... ... Print:...... cEfiN�/ .......... Gi ............................ �a llv Date:.......... '...................... FireMarshal: .............................................. . ..... . .. . . ........................ Print:..................,.............................................................. Date:.................................. ULPAK 1 MLN I AG I iUN: Atter (jetermmatlon, copies to: l) applicant, z) permit The Aliform 2015.doc revised 07/01/15 t CUPERTINO PURPOSE: CALGREEN RESIDENTIAL CHECKLIST - MANDATORY ITEMS COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION ALBERT SALVADOR, P.E., C.B.O., BUILDING OFFICIAL RECEIVED J Y ED 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building(a)cupertino.org JUN 2 9 2015 The 2013 CalGreen Code applies to additions or alterations of existing residentiaPg ' s w ere the addition or alteration increases the building's conditioned area, volume, or size and also applies to all new low-rise residential buildings, high-rise residential buildings, or both. Existing site and landscaping improvements that are not otherwise disturbed are not subject to the requirements of CALGreen. Project Name: Project Address: Project Description: Instructions: S"' UP AOITrA i 1. The Owner or the Owner's agent shall employ a licensed professional experienced with the California Green Building Standards Codes to verify and assure that all required work described herein is properly planned and implemented in the project. 2. The licensed professional, in collaboration with the owner and the design professional shall initial Column 2 of this checklist, sign and date Section 1 - Design Verification at the end of this checklist and have the checklist printed on the approved plans for the project. 3. Prior to final inspection by the Building Department, the licensed professional shall complete Column 3 and sign and date Section 2 - Implementation Verification at the end of this checklist and submit the completed form to the Building Inspector. Page I of 5 CalGreen 2014.doc revised 11/04/14 Column 2 Column3 MANDATORY FEATURE OR MEASURE Project Verification Re uirements .. .1 PLANNING AND DESIGN Planning and Design - Site Development 4.106.2 Storm water drainage and retention during construction. A plan is developed and implernented to manage storm water drainage during EJ El construction. m 4.106.3 Grading and paving. The site shall be planned and developed to keep surface water away from buildings. Construction plans shall indicate how site grading or a drainage system will manage all surface water flows. s1 Page I of 5 CalGreen 2014.doc revised 11/04/14 A4.2 General 4.201.1 Low-rise residential buildings shall meet or exceed the minimum ® ❑ standard design required by the California Energy Standards. A4.3 WATER EFFICIENCY AND CONSERVATION Indoor Water Use 4.303.1 Water conserving plumbing fixtures and fittings. Plumbing fixtures (water closets and urinals) and fittings (faucets and showerheads) shall comply with the following: S f 60 13 4.303.1.3.2 Water Closets. The effective flush volume of all water closets shall not exceed 1.28 gallons per flush. Tank -type water closets shall be certified to the performance criteria of the U.S. EPA WaterSense Specifications for Tank -type Toilets. ❑ 4.303.1.3.2 Urinals. The effective flush volume of urinals shall not exceed 0.5 gallons per flush. 4.303.1.3.1 Single Showerheads. Showerheads shall have a maximum flow rate of not more than 2.0 gallons per minute at 80 psi. Showerheads shall be certified to the performance criteria of the U.S. EPA WaterSense Specification for showerheads. ❑ 4.303.1.3.2 Multiple Showerheads serving one shower. When a shower is served by more than one showerhead, the combined flow rate of all showerheads and/or other shower outlets controlled by a single valve shall not exceed 2.0 gallons per minute at 80 psi, or the shower shall be ❑ designed to allow only one shower outlet to be in operation at a time. 4.303.1.4.1 Residential lavatory faucets. The maximum flow rate of residential lavatory faucets shall not exceed 1.5 gallons per minute at 60 psi. The minimum flow rate of residential lavatory faucets shall not be less than 0.8 gallons per minute at 20 psi. ❑ 4.303.1.3.2 Lavatory faucets in common and public use areas. The maximum flow rate of lavatory faucets installed in common and public use areas (outside of dwellings or sleeping units) in residential buildings shall not exceed 0.5 gallons per minute at 60 psi. ❑ 4.303.1.4.3 Metering faucets. Metering faucets when installed in residential buildings shall not deliver more than 0.25 gallons per cycle. 4.303.1.4.4 Kitchen Faucets. The maximum flow rate of kitchen faucets shall not exceed 1.8 gallons per minute at 60 psi. Kitchen faucets may temporarily increase the flow above the maximum rate, but not to exceed 2.2 gallons per minute at 60 psi, and must default to a maximum flow rate of 1.8 gallons per minute at 60 psi. 4.303.2 Standards for plumbing fixtures and fittings. Plumbing fixtures and fittings shall be installed in accordance with the California Plumbing Code, ❑ ❑ and shall meet the applicable standards referenced in Table 1401.1 of the California Plumbing Code. Page 2 of 5 CalGreen_2014.doc revised 11/04/14 Outdoor Water Use 4.304.1 Irrigation controllers. Automatic irrigation systems installed at the t time of final inspection shall be weather -based. / ❑ 4.304.1.1 Controllers shall be weather- or soil moisture -based controllers that automatically adjust irrigation in response to changes in plants' needs as weather conditions change. 1�1 C�1 ❑ ❑ 4.304.1.2 Weather -based controllers without integral rain sensors or communication systems that account for local rainfall shall have a separate wired or wireless rain sensor which connects or communicated with the controller(s). Soil moisture -based controllers are not required to have rain sensor input. .. .4 MATERI I L CONSERVATION AND RESOURCE EFFICIENCY Enhanced Durability and Reduced Maintenance 4.406.1 Rodent proofing. Annular spaces around pipes, electric cables,{two conduits, or other openings in plates at exterior walls shall be protected 13 ❑ against the passage of rodents by closing such openings with cement mortar, concrete masonry or similar method acceptable to the enforcing agency. Construction Waste Reduction, Disposal and Recycling 4.408.2 Construction waste management plan. Where a local jurisdiction S 6 VN does not have a construction and demolition waste management ordinance, a ❑ construction waste management plan shall be submitted for approval to the enforcing agency. Building Maintenance and Operation 4.410.1 Operation and maintenance manual. At the time of final inspection, an operation and maintenance manual shall be provided to the building ® ❑ occupant or owner. .. .5 ENVIRONMENTAL QUALITY Fireplaces 4.503.1 General. Install only a direct -vent sealed -combustion gas or sealed r �I ❑ wood -burning fireplace, or a sealed woodstove. Pollutant Control 4.504.1 Covering of duct openings and protection of mechanical lick Z 6w.i equipment during construction. Duct openings and other related air E3 ❑ distribution component openings shall be covered during construction. 4.504.2.1 Adhesives, sealants and caulks. Adhesives, sealants and caulks ti -ox 3` 1SHf- ® ��� ❑ shall be compliant with VOC and other toxic compound limits. 4.504.2.2 Paints and coatings. Paints, stains and other coatings shall be ❑ ❑ compliant with VOC limits. 4.504.2.3 Aerosol paints and coatings. Aerosol paints and other coatings IT* 3. Z shall be compliant with product weighted MIR Limits for ROC and other toxic f �� ❑ compounds. Page 3 of 5 CalGreen 2014.doc revised 11/04/14 4.504.2.4 Verification. Documentation shall be provided to verify that d6jk �`" icompliant �� ❑ VOC limit finish materials have been used. i 4.504.3 Carpet Systems. Carpet and carpet systems shall be compliant with No �l ,rl� ❑ VOC limits. 4.504.4 Resilient flooring systems. Eighty (80) percent of floor area No 5 receiving resilient flooring shall comply with the VOC-emission limits defined in the Collaborative for High Performance Schools (CHPS) Low -emitting ® ❑ Materials List or be certified under the Resilient Floor Covering Institute (RCFI) FloorScore program. 4.504.5 Composite wood products. Particleboard, medium density 4' N�I7A fiberboard (MDF), and hardwood plywood used in interior finish systems shall fl ❑ comply with low formaldehyde emission standards. Interior Moisture Control 4.505.2 Concrete slab foundation. Required vapor retarders and capillary ❑ breaks are also required to comply with CalGreen Section 4.505.2.1. �f Pak> 4.505.3 Moisture content of building materials. Moisture content of building ��SAf- ❑ materials used in wall and floor framing is checked before enclosure. (�N{ Indoor Air Quality and Exhaust 4.506.1 Bathroom exhaust fans. Exhaust fans which terminate outside the ® ❑ building are provided in every bathroom. Environmental Comfort 4.507.2. Duct systems are sized and designed and equipment is selected AJ /a - using the following methods: 1. Establish heat loss and heat gain values according to ACCA Manual J or equivalent. E ❑ 2. Size duct systems according to ACCA 29-D (Manual D) or equivalent. 3. Select heating and cooling equipment according to ACCA 36-S (Manual S) or equivalent. INSTALLER ANDSPECIAQUALIFICATIONS L INSPECTOR Qualifications 702.1 Installer training. HVAC system installers are trained and certified in sa ❑ ❑ the proper installation of HVAC systems. 702.2 Special inspection. The Licensed Professional responsible to verify CALGreen compliance is qualified and able to demonstrate competence in the ❑ ❑ discipline they inspect and verify. Verifications 703.1 Documentation. Verification of compliance with CALGreen may include construction documents, plans, specifications, builder or installer certification, inspection reports, or other methods acceptable to the enforcing ® ❑ agency which show substantial conformance. Implementation verification shall be submitted to the Building Department after implementation of all required measures and prior to final inspection approval. Page 4 of 5 CalGreen_2014.doc revised 11/04/14 Project Name: Project Address: Project Description: CALGREEN SIGNATURE DECLAIRATIONS llote SECTION 1 - DESIGN VERIFICATION Complete all lines of Section 1 — "Design Verification" and submit the completed checklist (Columns 1 and 2) with the plans and building permit application to the Building Department. The owner and design professional responsible for compliance with CalGreen Standards have revised the plans and certify that the items checked above are hereby incorporated into the project plans and will be implemented into the project in accordance with the requirements set forth in the 2013 California Green Building Standards Code as adopted byte Cityuper o. a Owner's Signature Sre� b� Owner's Name (Please Print) ---\S Design Professional's Signature 6u - X056 ZEE Design Professional's Name (Please Print) Signature of License Professional responsible for ClIGr compliai e" Name of License Profession I responsible for CalGreen compliance (Please Print) -I?j /I� 6-(- (9) L4 0 k,60, CO u-. Email Address for Licerfse Professional*6sponsible for CalGreen compliance SECTION 2 - IMPLEMENTATION VERIFICATION Date IZ61(-5'- Date (?, 09) Phone Complete, sign and submit the competed checklist, including column 3, together with all original signatures on Section 2 to the Building Department prior to Building Department final inspection. I have inspected the work and have received sufficient documentation to verify and certify that the project identified above was constructed in accordance with this Green Building Checklist and in accordance with the requirements of the 2013 California Green Building Standards Code as adopted by the City of Cupertino. Signature of License Professional responsible for CalGreen compliance Date Name of License Professional responsible for CalGreen compliance (Please Print) Phone Email Address for License Professional responsible for CalGreen compliance Page 5 of 5 CalGreen_2014.doc revised 11/04/14 BUILDING ENERGY ANALYSIS REPORT PROJECT: Remodel addition 21331 Columbus AvRECEIVED Cupertino, CA 95014 JUN 2 9 2015 Project Designer: BY 0 OIgE ZEPEDA 0'F"tF-ICE C 1 1 Fir Lane CERES, CA Report Prepared by: Tailored Energy Services - Title 24 Calculations, Kevin Laughton www.TailoredEnergyOnline.com Kevin@TailoredEnergyOnline.com Job Number: 5531 Date: 26-Jun-15 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. Ener Pro 6.6 by Ener Soft User Number: 5308 ID: 5531 I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF -1 R -PRF -01-E Certificate of Compliance 3 Form RMS -1 Residential Measures Summary 11 Form MF -1 R Mandatory Measures Summary 12 HVAC System Heating and Cooling Loads Summary 16 Room Load Summary 17 Room Heating Peak Loads 18 EnergyPro 6.6 by EnergySoft ID: 5531 User Number: 5308 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Remodel addition Calculation Description: Title 24 Analysis Calculation Date/Time: 08:02, Fri, Jun 26, 2015 Input File Name: 5531 21331 Columbus Ave add rmdl.xml CF1 R -PRF -01` Page 1 of 8 GENERAL INFORMATION 01 Building Complies with Computer Performance 01 Project Name Remodel addition 03 This building incorporates one or more Special Features shown below 02 Calculation Description Title 24 Analysis 08 Energy Use (kTDV/ft2-yr) 03 Project Location 21331 Columbus Ave Compliance Margin Percent Improvement 04 City Cupertino 05 Standards Version Compliance 2015 06 Zip Code 95014 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ4 09 Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 270 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 3002 15 Number of Zones 2 16 Slab Area (ft2) 0 17 Number of Stories 1 18 Addition Cond. Floor Area 818 19 Natural Gas Available Yes 20 Addition Slab Area (ft) 0 21 Glazing Percentage (%) 17.6% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below 06 Registration Number: 215-A0169582B-000000000-0000 Registration Date/Time: 2015-06-26 08:44:44 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-06232015-744 Report Generated at: 2015-06-26 08:03:44 ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 19.38 22.58 -3.20 -16.5% Space Cooling 7.93 7.21 0.72 9.1% IAQ Ventilation 0.00 0.00 0.00 0.0% Water Heating 10.11 7.16 2.95 29.2% Photovoltaic Offset ---- 0.00 0.00 ---- Compliance Energy Total 37.42 36.95 0.47 1.3% Registration Number: 215-A0169582B-000000000-0000 Registration Date/Time: 2015-06-26 08:44:44 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-06232015-744 Report Generated at: 2015-06-26 08:03:44 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Remodel addition Calculation Description: Title 24 Analysis Calculation Date/Time: 08:02, Fri, Jun 26, 2015 Input File Name: 5531 21331 Columbus Ave add rmdl.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Cathedral Ceiling • Ceiling has high level of insulation HERS FEATURE SUMMARY CF1 R -PRF -01 - Page 2 of 8 The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: --None -- Cooling System Verifications: --None -- HVAC Distribution System Verifications: • Verified low -leakage ducts located entirely in conditioned space Domestic Hot Water System Verifications: --None -- ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. 02 Reference Energy Use Energy Design Rating Margin Percent Improvement Total Energy (kTDV/f2-yr)* 80.97 80.50 0.47 0.6% * includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Remodel addition 3002 1 7 2 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Current Conditioned currrentl 2184 8 DHW Sys 1 new areas Conditioned currrenti 818 8 DHW Sys 1 Registration Number: 215-A0169582B-000000000-0000 Registration Date/Time: 2015-06-2608:44:44 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-06232015-744 Report Generated at: 2015-06-26 08:03:44 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Remodel addition Calculation Date/Time: 08:02, Fri, Jun 26, 2015 Calculation Description: Title 24 Analysis Input File Name: 5531 21331 Columbus Ave add rmdl.xml CF1 R -PRF -01 Page 3 of 8 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft2) Tilt (deg) Status Verified Existing Condition W Wall Current Default Wali Prior to 197 270 Front 270 84 90 Existing No s Wall Current Default Wall Prior to 197 180 Right 200 47 90 Existing No N Wall Current Default Wall Prior to 197 0 Left 110 72 90 Existing No E Wall Current Default Wall Prior to 197 90 Back 250 55 90 Existing No Roof 4 Current roof 0.33 18.43 2180 0.85 0.1 Existing No Raised Floor Current Default Floor Crawlspace 2184 Existing No N Wall new areas R-19 Wall 0 Left 200 180 90 New N/A S Wall new areas R-19 Wall 180 Right 75 New 90 New N/A E Wall 2 new areas R-19 Wail 90 Back 165 84 90 New N/A s Wall 2 new areas R-15 Walla 180 Right 175 20 90 New N/A W Wall new areas R-15 Walll 270 Front 100 90 New N/A E Wail 3 new areas R-15 Wall1 90 Back 100 90 New N/A Roof 5 new areas R-38 Roof Attic 676 New N/A Roof 6 new areas R-38 Roof Attic 140 New N/A Raised Floor 2 new areas Default Floor Crawlspace 676 New N/A Raised Floor 3 new areas Default Floor Crawlspace 142 Existing No OPAQUE SURFACES — Cathedral Ceilings 01 02 03 04 05 06 07 08 09 10 11 12 13 Roof Framin Verified Orientatio Area Skylight Roof Rise Roof Roof Reflectan Roof g Statu Existing Name Zone Type n (ft2) Area (ft2) (x in 12) Pitch Tilt(deg) ce Emittance Factor s Condifion Roof 2 Current roof Left 4.1 2 4 0.33 18.43 0.1 0.85 0.1 Exigstin No Roof 3 new areas R-38 Roof Attica Left 2.1 2 4 0.33 18.43 0.1 0.85 0.07 New N/A Registration Number: 215-A0169582B-000000000-0000 Registration Date/Time: 2015-06-26 08:44:44 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-06232015-744 Report Generated at: 2015-06-26 08:03:44 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Remodel addition Calculation Description: Title 24 Analysis Calculation Date/Time: 08:02, Fri, Jun 26, 2015 Input File Name: 5531 21331 Columbus Ave add rmdl.xml CF1 R -PRF -01^ Page 4 of 8 ATTIC 01 02 03 04 05 06 07 08 09 10 Name Construction Type Root Rise Root Reflectance Roof Emittance Radiant Barrier Cool Root Statu s Verified Existing Condition Attic Current Attic RoofCurrent Ventilated 4 0.1 0.85 No No Existi ng No Attic new areas Attic Roofnew areas Ventilated 1 4 1 0.1 0.85 Yes No New No WINDOWS 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width(ft) Height (ft) Multiplie r Area (ft2) U -factor SHGC Exterior Shading Status Verified Existing Condition Window e W Wall (Front -270) ---- ---- 1 78.0 0.23 0.19 Insect Screen (default) Existing No Window n W Wall (Front -270) ---- ---- 1 6.0 0.30 0.25 Insect Screen (default) Altered N/A Window n 2 s Wall (Right -180) ---- ---- 1 47.0 0.30 0.25 Insect Screen (default) Altered N/A Window e 2 N Wall (Left -0) ---- ---- 1 72.0 0.23 0.19 Insect Screen (default) Existing No Window e 3 E Wall (Back -90) ---- ---- 1 55.0 0.23 0.19 Insect Screen (default) Existing No Skylight Roof 2 (Left -0) ---- ---- 1 2.0 0.30 0.25 None New N/A Skylight e Roof 2 (Left -0) ---- ---- 1 2.0 0.23 0.19 None Existing No Window N Wall (Left -0) ---- ---- 1 150.0 0.55 0.67 Insect Screen (default) New N/A Window e 4 N Wall (Left -0) ---- 1 30.0 0.23 0.19 Insect Screen (default) Existing No Window 2 E Wall 2 (Back -90) ---- ---- 1 84.0 0.30 0.25 Insect Screen (default) New N/A Skylight 2 Roof 3 (Left -0) ---- 1 2.0 0.30 1 0.25 None New N/A DOORS 01 02 03 04 05 06 Name Side of Building Area (ft2) U -factor Status Verified Existing Condition Door s Wall 2 20.0 0.50 New No Registration Number: 215-A0169582B-000000000-0000 Registration Date/Time: 2015-06-26 08:44:44 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - MR -06232015-744 Report Generated at: 2015-06-26 08:03:44 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Remodel addition Calculation Date/Time: 08:02, Fri, Jun 26, 2015 Calculation Description: Title 24 Analysis Input File Name: 5531 21331 Columbus Ave add rmdl.xml CF1 R -PRF -01 Page 5 of 8 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers • Cavity / Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofCurrent Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity/ Frame: no insul. / 2x4 • Exterior Finish: Wood Default Wall Prior to 197 Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. none 0.302 Siding/sheathing/decking • Inside Finish: Gypsum Board Ceilings (below Cavity/ Frame: R-9.1 / 2x4 roof attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 19 0.049 Over Floor Joists: R-9.9 insul. • Inside Finish: Gypsum Board • Cavity / Frame: R-19 / 2x4 • Roof Deck: Wood Siding/sheathing/decking roofs Cathedral Ceilings Wood Framed Ceiling 2x4 @ 16 in. O.C. R 19 0.061 Roofing: Light Roof (Asphaft Shingle) • Floor Surface: Carpeted Floors Over Floor Deck: Wood Siding/sheathing/decking Default Floor Crawlspace Crawlspace Wood Framed Floor 2x12 @ 16 in. O.C. none 0.216 Cavity/ Frame: no insul. /2x12 • Cavity / Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic Roofnew areas Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity / Frame: R-19 / 2x6 • Exterior Finish: Wood R-19 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 0.069 Siding/sheathing/decking • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 0.025 Over Floor Joists: R-28.9 insul. • Inside Finish: Gypsum Board • Sheathing / Insulation: R4 Sheathing • Cavity/ Frame: R -15/2x4 R-15 Walls Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 15 0.050 Exterior Finish: R4 Synthetic Stucco • Inside Finish: Gypsum Board • Cavity / Frame: R-38 / 2x4 • Roof Deck: Wood Siding/sheathing/decking R-38 Roof Attica Cathedral Ceilings Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 0.036 Roofing: Light Roof (Asphalt Shingle) Registration Number: 215-A0169582B-000000000-0000 Registration Date/Time: 2015-06-26 08:44:44 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - MR -06232015-744 Report Generated at: 2015-06-26 08:03:44 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Remodel addition Calculation Description: Title 24 Analysis Calculation Date/Time: 08:02, Fri, Jun 26, 2015 Input File Name: 5531 21331 Columbus Ave add rmdl.xml CF1 R -PRF -01 Page 6 of 8 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction M Status Verified Existing Condition DHW Sys 1 DHW Standard DHW Heater 1 1 Annual Altered No WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small instantaneous 0 0.84 EF 185000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1 n/a n/a n/a n/a n/a n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Heating System Cooling System Distribution Fan Floor Area Verified Existing Name System Type Name Ducted Name Ducted System System Served Status Condition currrenti Other Heating and Heating Yes Cooling Yes Air Distribution HVAC Fan 3002 Existing No Cooling System Component 1 Component 1 System 1 1 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntrlFurnace - Fuel -fired central furnace 80 AFUE Registration Number: 215-A0169582B-000000000-0000 Registration Date/Time: 2015-06-26 08:44:44 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-06232015-744 Report Generated at: 2015-06-26 08:03:44 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Remodel addition Calculation Date/Time: 08:02, Fri, Jun 26, 2015 Calculation Description: Title 24 Analysis Input File Name: 5531 21331 Columbus Ave add rmdl.xml CF1 R -PRF -01 Page 7of8 HVAC - COOLING SYSTEMS 01 02 03 04 05 06 07 07 08 Efficiency 10 Multi -speed Duct Leakage Verification Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 PkgAirCond - Central packaged A/C 9.8 11 No No N/A Location system (< 65 kBtuh) Status Condition Verification Air Distribution Ducts located entirely in HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 Name Duct Leakage Verification Duct Leakage Target (%) Insulation Supply Duct Return Duct N/A F Verified Existing HERS Name Type Duct Leakage R -value Location Location Bypass Duct Status Condition Verification Air Distribution Ducts located entirely in Existing (not 4'2 Conditioned Conditioned None Existing No N/A System 1 conditioned space specified) Zone Zone HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Return Supply Air Distribution System 1 -hers -dist N/A F Ducts located entirely in conditioned space IAQ (Indoor Air Quality) FANS 01 02 03 04 05 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 0 Default 0 Not Required Registration Number: 215-A0169582B-000000000-0000 Registration Date/Time: 2015-06-26 08:44:44 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-06232015-744 Report Generated at: 2015-06-26 08:03:44 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Remodel addition Calculation Date/Time: 08:02, Fri, Jun 26, 2015 Calculation Description: Title 24 Analysis Input File Name: 5531 21331 Columbus Ave add rmdl.xml CF1 R -PRF -01 Page 8 of 8 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Kevin Laughton �evc�aL� Company: Signature Date: Tailored Energy Services 2015-06-26 08:08:46 Address: CEA/HERS Certification Identification (If applicable): 1640 West Longview Ave City/State/Zip: Phone: Stockton, CA 95207 888 310 0808 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Jose Zepeda Company: Date Signed: Zepeda Engineering 2015-06-26 08:44:44 Address: License: 1821 FIR LN tba City/State/Zip: Phone: 6 CERES, CA 95307 2095310592 alSo 996 - F-5'70 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 215-A0169582B-000000000-0000 Registration Date/Time: 2015-06-26 08:44:44 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFiR-06232015-744 Report Generated at: 2015-06-26 08:03:44 RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Remodel addition Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 26 -Jun -15 Project Address 21331 Columbus Ave Cupertino California Energy Climate Zone CA Climate Zone 04 Total Cond. Floor Area 3,002 Addition 818 # of Units 1 INSULATION Construction Cavity Area (ft) Special Features Status _Type Wall Wood Framed - no insulation 572 Existing Roof Wood Framed Attic R 19 2,180 Existing Floor Wood Framed w/Crawl Space - no insulation 2,326 Existing Wall Wood Framed R 19 176 New Roof Wood Framed Attic R38 816 New Floor Wood Framed w/Crawl Space - no insulation 676 New Demising Wood Framed R 15 565 Rigid=R-9.0 New Door Opaque Door - no insulation 20 New FENESTRATION TTotal Area: 528 Glazing Percentage: 17.6 % Orientation Area(ft) U -Fac SHGC Overhang Sidefins New/Altered Average U -Factor: Exterior Shades 0.43 Status Front (W) 78.0 x230 0.19 none none Bug Screen Existing Front (W) 6.0 0.300 0.25 none none Bug Screen Altered Right (S) 47.0 0.300 0.25 none none Bug Screen Altered Skylight 2.0 0.300 0.25 none none None New Skylight 2.0 0.230 0.19 none none None Existing Left (N) 102.0 0.230 0.19 none none Bug Screen Existing Rear (E) 55.0 0.230 0.19 none none Bug Screen Existing Left (N) 150.0 0.550 0.67 none none Bug Screen New Rear (E) 84.0 0.300 0.25 none none Bug Screen New Skylight 2.0 0.300 0.25 none none None New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Packaged Air Condition 11.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Cooling Duct Location Duct R -Value Status currrent Ducted Ducted Conditioned 4.2 Existing WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 1 Small Instantaneous Gas 0 0.84 Standard Altered Ener Pro 6.6 by Ener Soft User Number., 5308 RunCode: 2015-06-26T08:05:52 ID: 5531 Pae 11 of 20 2013 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. Exceptions may apply. Review the respective code section for more information. Building Envelope Measures: §I 10.6(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. § 110.6(a)5: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of § 10-111 (a). § 110.7: Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed. § 110.8(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R. § 110.8(1): The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the installation of a cool roof is specified on the CFIR. § 110.80): A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CF 1 R. Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a § 150.0(a): rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The attic access shall be gasketed to prevent air leakage. § 150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -value. §I50.0(c): Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U - factor). § 150.0(d): Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor. In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior § 150.0(g)1: wails, vented attics and unvented attics with air -permeable insulation. In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class 11 § I50.0(g)2: vapor retarder. In a building having a controlled ventilation crawl space, a Class I or Class 11 vapor retarder shall be placed over the earth floor of §150.0(g)3: the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section 150.0(d). § 150.0(1): Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration; and when installed as part of a heated slab floor meets the requirements of § 1 10.8 . § 150.0(q): Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U - factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58. Fireplaces, Decorative Gas Appliances and Gas Log Measures: §150.0(e)IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. § I50.0(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting dam er or a combustion -air control device. § 150.0(e)IC: Masonry or factory -built fireplaces have a flue damper with a readily accessible control. § 150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: § 110.0-§ 110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission. § 110.3(c)5: Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of § 110.3(c)5. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli- § 110.5: ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. § 150.0(h)1: Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified in § 150.0(h)2. §150.0(h)3A: Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any dryer vent. § I50.0(i): Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c). § 150.00)1A: Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. § 150.0(j)1B: Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system §150.00)2A: regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3- A. § 150.00 )2B: All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve that allows for installation, removal, and replacement of the enclosed pipe and insulation. . 2013 Low -Rise Residential Mandatory Measures Summary § 150.00)2C: Pipe for cooling system lines shall be insulated as specified in § 150.00)2A. Piping insulation for steam and hydronic heating systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A. § 150.00)3: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For § 150.0(i)3A: example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or painted with coating that is water retardant and provides shieldinit from solar radiation that degrades the material. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I § 150.00)3B: or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor retarder. Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the § 150.0(n)1: space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5. § 150.0(n)3: Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC) or by a testing agency approved by the Executive Director. Ducts and Fans Measures: All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0, §603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Supply -air and retum-air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC §605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed § 150.0(m)1: with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than '/, inch, the combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints § 150.0(m)2: and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. §150.0(m)3-6: Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling. § 150.0(m)7: All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § 150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers except combustion inlet and outlet air openings and elevator shaft vents. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not § 150.0(m)9: limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)10: Flexible ducts cannot have porous inner cores. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be § 150.0(m)11: sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal § 150.0(m)12: conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of 150.0 m 12. Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The § 150.0(m)13: space conditioning system must also demonstrate airflow > 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode, § 150.0(m)15: an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of>_ 350 CFM per ton of nominal cooling capacity, and operating at an air -handling unit fan efficacy of <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of § 150.0(0): central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the Whole Building Ventilation. §150.0(o)lA: Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Pool and Spa Heating Systems and Equipment Measures: Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency § 110.4(a): Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating. ' 2013 Low -Rise Residential Mandatory Measures Summary §110.4(b)l: Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction and return lines, or built-up connections for future solar heating. § 110.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. §110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro - mmed to run only during off-peak electric demand periods. § 110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light. § 150.0(p): Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements. Lighting Measures: § 110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9. §150.0(k)IA: Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with §I50.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B, as applicable. § 150.0(k)I B: When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply with the applicable provisions of § 150.0(k). The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with § 150.0(k) I C: § 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180 watts of low efficacy lighting er electrical box. §150.0(k)ID: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no § 150.0(k) I E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vacancy sensors. § I50.0(k)I F: Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable requirements of § 150.0(k). § 150.0(k)2A: High efficacy luminaires must be switched separately from low efficacy luminaires. § 150.0(k)2B: Exhaust fans shall be switched separately from lighting systems. § 150.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Controls and equipment are installed in accordance with manufacturer's instructions. § 150.0(k)2E: No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § 150.0(k). § 150.0(k)2F: Lighting controls comply with applicable requirements of § 110.9. An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer § 150.0(k)2G: according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in § 150.0(k)2. An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § 150.0(k) if. it § 150.0(k)2H: functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in § 150.0(k)2. § 150.0(k)21: A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2. § 150.0(k)3A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only § 150.0(k)3B: the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are considered kitchen lighting if they are not separately switched from kitchen lighting. § 150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. § I50.0(k)5: A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. § 150.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. § 150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing § I50.0(k)8: and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and allow ballast maintenance and replacement without requiring cutting holes in the ceiling. For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § 150.0(k), the ballasts shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9. For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and § I50.0(k)9A: ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours; and iii. Controlled by one of the followin methods: 2013 Low -Rise Residential Mandatory Measures Summary a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with § 110.9; meets the Installation Certification requirements in § 130.4; meets the requirements for an EMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the § 150.0(k)9B: following requirements: i. Shall comply with § 150.0(k)9A; or ii. Shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0. § 150.0(k)9C: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0. § I50.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0. § 150.0(k)10: Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined according to § 130.0(c). § 150.0(k)11: Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in § 110.9, § 130.0 § 130. 1, § 130.4, § 140.6, and § 141.0. In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of § 150.0(k)12A: the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: § 150.0(k)12B: i. Comply with the applicable requirements in § 110.9, § 130.0, § 130. 1, § 140.6 and § 141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. Solar Ready Buildings: Single family residences located in subdivisions with ten or more single family residences and where the application for a § 110.10(a)l: tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014, shall comply with the requirements of § 110.10 b through 110.10(e). § 110.10(a)2: Low-rise multi -family buildings shall comply with the requirements of § 110.10(b) through § 110.10(d). The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for § 110.10(b)1: buildings with roof areas greater than 10,000 square feet. For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. § 110.10(b)2: All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be located in the solar zone. Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice § 110.10(b)3B: the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical plane. § 110.10(b)4: For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly indicated on the construction documents. The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit §110.10(c): from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating system. §110.10(d): A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c) shall be provided to the occupant. § 110.10(e)1: The main electrical service panel shall have a minimum busbar rating of 200 amps. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a § 110.10(e)2: future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or main circuit location, and permanently marked as "For Future Solar Electric". HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Remodel addition Date 26-Jun-15 System Name curr-ent Floor Area 3,002 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,274 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 35,000 27,259 1,686 755 38,058 Total Output (Btuh) 35,000 0 Output Stuhl ft 11.7 284 478 Cooling System 0 0 Output per System 59,500 0 0 0 0 Total Output Stuh 59,500 2,302 1,6861 -2,302 Total Output ons 5.0 284 478 Total Output (Btuh/s ft) 19.8 Total Output s ft/Ton 605.4 1 30,1291 36,711 Air System CFM per System 1,916 HVAC EQUIPMENT SELECTION Alrflow cfm 1,916 current 49,403 7,280 35,000 Alrflow cfm/s ft 0.64 Airflow (cfm/Ton) 386.4 Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 49,403 7,280 35,000 Jan 1 AM Outside Air cfm/s ft) 0.00 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 28 OF 68 IF Outside Air 0 cfm Supply Fan 1,916 cfm 68 IF 69 OF 115, Heating Coil 115 OF Roots 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 88 / 68 OF Outside Air Ar 0 cfm 76 162 OF 55 / 54 OF Supply Fan Cooling Coil 1,916 cfm 55 / 54 OF 46.2% ROOM 75 / 61 OF EnergyPro 6.6 by EnergySoft User Number: 5308 RunCode: 2015-06-26T08:05:52 ID: 5531 Page 16 of 20 ROOM LOAD SUMMARY Project Name Date Remodel addition 26 -Jun -15 System Name Floor Area currrent 3,002 ROOM LOAD SUMMARY PAGE TOTAL TOTAL* 1,274 ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM I Sensible Current curent 1 796 17,040 1,227 796 17,040 1,227 528 26,625 new areas addition rear 1 435 9,309 380 435 9,309 380 186 9,385 addition garage conversiol 1 43 910 80 43 910 80 41 Z048 PAGE TOTAL TOTAL* 1,274 27,2591 1,6861 755 38,058 1,274 27,2591 1,6861 551 38,058 * Total includes ventilation load for zonal systems. EnergyPro 6.6 by EnergySoft User Number: 5308 RunCode: 2015-06-26T08:05:52 ID: 5531 Pae 17 of 20 ROOM HEATING PEAK LOADS Project Name Remodel addition Date 26-Jun-15 ROOM INFORMATION DESIGN CONDITIONS Room Name curent Floor Area 2,184.0 ft2 Indoor Dry Bulb Temperature 68 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 28 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 40 Btu/hr Default Wall Prior to 1978 572.0 0.3560 40 8,145 dual 207.0 0.2300 40 1,904 new 55.0 0.3000 40 660 roof 2,180.0 0.0490 40 4,273 Default Floor Crawlspace Prior to 1991 2,184.0 0.0970 40 8,474 Items shown with an asterisk (*) denote conduction Infiltration:[ 1.00 X 1.077 Schedule Air Sensible Fraction through an interior surface X 2,184 X Area another room 8.00 X 0.253 Height ACH Page Total /60] X AT 23,456 = C 3,168 TOTAL HOURLY HEAT LOSS FOR ROOM 26,625 EnergyPro 6.6 by EnergySoft User Number: 5308 RunCode: 2015-06-26708:05:52 ID: 5531 Page 18 of 20 ROOM HEATING PEAK LOADS Project Name Remodel addition ROOM INFORMATION Room Name Floor Area Indoor Dry Bulb Temperature Conduction R-19 Wall nano wall dual R-38 Roof Attic Default Floor Crawlspace Prior to 1991 *R-15 Wall addition rear Time of Peak 676.0 ft2 Outdoor Dry Bulb Temperature 68 °F Area U -Value AT OF 176.0 150.0 30.0 676.0 676.0 155.0 84.0 0.0740 0.5500 0.2300 0.0250 0.0970 0.0512 0.3000 26 -Jun -15 Jan 1 AM 28 OF Btu/hr 521 3,300 276 676 2, 623 0 1,008 Items shown with an asterisk (*) denote conduction through an interior surface to another room Page Total 8,404 Infiltration:[ 1.00 X 1.077 X 676 X 8.00 X 0.253 / 60 1 X 40 _ 981 Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 9,385 ROOM HEATING PEAK LOADS Project Name Remodel addition Date 26 -Jun -15 ROOM INFORMATION DESIGN CONDITIONS Room Name addition garage conversion Floor Area 142.0 ft2 Indoor Dry Bulb Temperature 68 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 28 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF = = = = = = = = = = = = = = = = = = = = = = = e = = = 40 Btu/hr R-15 Wall 355.0 0.0512 40 727 Wood Door 20.0 0.5000 40 400 R-38 Roof Attic 140.0 0.0250 40 140 new 2.0 0.3000 40 24 Default Floor Crawlspace Prior to 1991 142.0 0.0970 40 551 'R-15 Wall 55.0 0.0512 0 0 Items shown with an asterisk (`) denote conduction Infiltration:[ 1.00 X 1.077 Schedule Air Sensible Fraction through an interior surface X 142 X Area another room 8.00 X 0.253 Height ACH Page Total /60] X AT 1,842 = 206 TOTAL HOURLY HEAT LOSS FOR ROOM 2,048 EnergyPro 6.6 by EnergySoft User Number. 5308 RunCode: 2015-06-267'08:05:52 ID: 5531 Page 20 of 20