15090135-CANCELLED • f D SolarCity junc.-i0, 2016 Dear Sir or Madam: This letter is to inquire about cancelling the permit for the following customer: Srinivasa Murthy 21820 Dolores Ave. Cupertino CA, 95014 Permit# 15090135 The customer has decided to cancel their solar project with SolarCity. We hereby request a refund of • fees, If possible. Refund checks can be mailed directly to the following address: ATTN: lona Villalba SolarCity Las Vegas 6671 S. Las Vegas Blvd - Ste. 300 Las Vegas, NV 89119-3290 If you have any questions or need anything.further, please let me know. Sincerely, 0 -1 Marjan Javanmard, Permit Coordinator \ \ (650)477-6430 m'avanmardCa�solarcit .com \) '0-111(0 1 Y _ 5\a 1 OD I r • zylo IP )j ��� Ir71i �, r 10 Oitki)(\ (Q1 k \.\ � 3()6 i ClaarvjQw Way San Mateo, CA 944CV i MO)C38 1028 (S9J)SOL CITY F(f5O)638 1Q29 SOLARCITY.COM at 1100 341711, CA C ILa f,8nlu4, LI) fC. RO4I, OP C.CB lAri4cfti,TX ifiLl 2700c .194;14 SoiarCity dwte-10, 2016 Dear Sir or Madam: This letter is to inquire about cancelling the permit for the following customer: Srinivasa Murthy 21820 Dolores Ave. Cupertino CA, 95014 Permit# 15090135 The customer has decided to cancel their solar project with SolarCity. We hereby request a refund of fees, If possible. Refund checks can be mailed directly to the following address: ATTN: lona Villalba SolarCity Las Vegas 6671 S. Las Vegas Blvd Ste. 300 Las Vegas, NV 89119-3290 If you have any questions or need anything further, please let me know. Sincerely, Marjan Javanmard, Permit Coordinator (650)477-6430 n-favanmard • solarcit .com AP-1-fr)MaiNteW Way 7r;,iti !Ow°,CA 04407 ( (6,W) (1 P) f-(OW(,3 -1020 $OLARCITY.COM CITY OF CUPERTINO BUILDING PERMIT INSPECTION CARD BUILDING ADDRESS:21820 DOLORES AVE CONTRACTOR:SOLARCITY PERMIT NO:15090135 OWNER'S NAME:MURTHY SRINIVASA D AND DHULIPALA 3055 CLEARVIEW WAY DATE ISSUED:09/21/2015 SR OWNER'S PHONE 4082043059 SAN MATED;CA 94402 PHONE NO: (650)638-1028 IL SP I JOB DESCRIPTION: RESIDENTIAL 0 COMMERCIAL 0 , FOUNDATIO N/PIERS/H.D.S. ; - INSTALL(N)ROOFTOP SOLAR PV-17 PANELS(4.42 KW) UFER GROUND ND INSTALL(N)125 AMP MAIN SERVICE PANEL PAD/SET BACK-CERT GARAGE SLABS/PREGUNITE SW 5N : 0 s, as SIGNED - "_; UNDERGROUND/SLAB UNDERGROUND PLUMBING 1111111011.111011111 UNDERGROUND ELECTRICAL It a, O'< €2®° T ,` By DalctEEI LGVID r ; UNDERFLOOR MECHANICAL T UNDERFLOOR ELECTRICALWILDLAND URBAN INTERFAC r'E AREA ER# UNDERFLOOR FRAMING VENTS TO NGE INSPECTION UNDERFLOOR INSULATION Call 777-3228 between 7:30 am :nd 3:30 pm Monday through Friday,at least 24 hours 0 PL p y inwi.} before required inspectio .Job address and Permit Numbers are needed when ROOF SHEATHING requesting an inspection. ROUGH PLUMBING UPERTINO SANITARY DISTRICT TUBS&SHOWER PAN Closed circuit vi eo inspection of property line cleanout,point of connection and street I, eral reprior to uiredpassingFINAL CITY PLUMBING ROUGH MECHANICAL q INSPEC t WON. Call the District(408-253-7071)for an appointment. ROUGH ELECTRICAL/POOL BOND I 'FRAMING/STAIRS/E.EGRESS I NO B d ILDING FINALS INSPECTIONS UNTIL ALL REQUIRED INSULATDII/VENTIL ��� BUSINESS LICENSES ARE OBTAINED ATION CD Ct �° ' + 'SI EO PERMI XPIRES IF WORK IS NOT STARTED WITHIN 180 DAYS OF PERMIT 411° w°11 11111f1 ISSUANCE OR 180 DAYS FROM LAST CALLED INSPECTION. INTERIOR SHEAR/HOLD DOWN SHEETROCK/SHEETROCK SHEAR AMIE IMPORTANT EXTERIOR LATH/W-SCREED en a permit has expired,a charge totaling one-half the fees to obtain a new permit list be paid in order to reactivate the permit.If a permit has been expired for more INTERIOR LATHthan one year,a charge totaling the full fees to obtain a new permit must be paid o l _ S EN_'SI I is to reactivate the permit. SCRATCH COAT . NOTES: T-BAR/MECH/ELECTABOVE CEIL ® _ ELECTRIC METER RELEASE � 111 SPECIAL INSPECTIONS Inspectors Dater. . ROOF INSPECTIONS GRADE PUBLIC WORKS PRE-INSPECTION:Inspector: Date: FIRE CALL(408)378-4010 TEAR-OFF: Inspector: Date:. PLANNING(408)777-3308 PLYWOOD Inspector: Date: SANITARY(408)253-7071 BATTENS: Inspector: Date. ELECTTRICAL — - = IN PROGRESS: Inspector: Date: ,MECHANICAL PLUMBING FINAL: Inspector: Date, HANDICAP � NOTE:OSHA APPROVED ACCESS TO ROOF SHALL BE PROVIDED FOR INSPECTION. ENERGY *OCCUPANCY OF BUILDING NOT PERMITTED UNTIL BUILDING FINAL IS SIGNED BY INSPECTOR BUILDING CERTIFICATE OF OCCUPANCY* CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 21820 DOLORES AVE CONTRACTOR:SOLARCITY PERMIT NO: 15090135 OWNER'S NAME: MURTHY SRINIVASA D AND DHULIPALA SR 3055 CLEARVIEW WAY DATE ISSUED:09/21/2015 OWNER'S PHONE: 4082043059 SAN MATEO,CA 94402 PHONE NO:(650)638-1028 LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL 0 COMMERCIAL 0 INSTALL(N)ROOFTOP SOLAR PV-17 PANELS(4.42 1(W) License Class(2(0 9 C,9-0 Lic.# G .S10 Ll. AND INSTALL(N)125 AMP MAIN SERVICE PANEL '..Contractor S b C--;4) Date I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: Sq.Ft Floor Area: Valuation:$9000 1. I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the APN Number:35714045.00 Occupancy Type: performance of the work for which this permit is issued. 2. I have and will maintain Worker's Compensation Insurance,as provided for by 60 Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. PERMIT EXPIRES IF WORK IS NOT STARTED APPLICANT CERTIFICATION WITHIN 180 DAYS OF PERMIT ISSUANCE OR I certify that I have read this application and state that the above information is 180 D S FROM LAST CALLED INS E TION, correct.I agree to comply with all city and county ordinances and state laws relating P G to building construction,and hereby authorize representatives of this city to enter g ( L S upon the above mentioned property for inspection purposes. (We)agree to save Issued by: l L`y`� I Date: indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which m,ac n-against said City in consequence of the granting of this permit. Ad itiorlal ,the applicant understands and will comply with RE-ROOFS: all non-point source -• ions'p-r the Cupertino Municipal Code,Section 9.18. All roofs shall be inspected prior to any roofing material being installed.If a roof is Signature Date q/L I /15 installed without first obtaining an inspection,I agree to remove all new materials for inspection. 0 OWNER-BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER the following two reasons: 1. I,as owner of the property,or my employees with wages as their sole compensation,will do the work,and the structure is not intended or offered for HAZARDOUS MATERIALS'DISCLOSURE sale(Sec.7044,Business&Professions Code) I have read the hazardous materials requirements under Chapter 6.95 of the 2. I,as owner of the property,am exclusively contracting with licensed contractors to California Health&Safety Code,Sections 25505,25533,and 25534. I will maintain construct the project(Sec.7044,Business&Professions Code). compliance with the Cupertino Municipal Code,Chapter 9.12 and the Health& Safety Code,Section 25532(a)should I store or handle hazardous material. I hereby affirm under penalty of perjury one of the following three declarations: Additionally,should I use equipment or devices which emit hazardous air 1. I have and will maintain a Certificate of Consent to self-insure for Worker's contaminants as defined b the Bay Area Air Quality Management District I will Compensation,as provided for by Section 3700 of the Labor Code,for the maintain compliance wethe C pertino Municipal Code,Chapter 9.12 and the performance of the work for which this permit is issued. Health&Safety Code.ections 5505,25533,and 25534. 2. I have and will maintain Worker's Compensation Insurance,as provided for by Owner or autho r• / 1 Section 3700 of the Labor Code,for the performance of the work for which this Date: —[ /�4 permit is issued. r` 3. I certify that in the performance of the work for which this permit is issued,I shall CONSTRUCTION LENDING AGENCY not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,I I hereby affirm that there is a construction lending agency for the performance of work's become subject to the Worker's Compensation provisions of the Labor Code,I Lr which this permit is issued(Sec.3097,Civ C.) Lender's Name must forthwith comply with such provisions or this permit shall be deemed revoked. Lender's Address APPLICANT CERTIFICATION ARCHITECT'S DECLARATION I certify that I have read this application and state that the above information is I understand my plans shall be used as public records. correct.I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter Licensed Professional upon the above mentioned property for inspection purposes.(We)agree to save indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section 9.18. Signature Date I ii 0)55 ALTERNATIVE ENERGY PERMIT APPLICATION iii0 , i' c.:0,,IM NI! DEVELOPMENT DPART livf.`:,iv1 - lir,nChii ri)�P,S,lia t.1# 2:u2 T ORRC AVENUE H FRTiiy CA 953-74-a25.5 UPERTIN 7-,,,,''d ri %_ ,&Alin iw it_C ti r r-- PROJECT ADDRESS c , 2 u Q�to ) v OWNER NAME GAY -4-\.1 (n S V L CA 1 PHONE c ... E-MAIL STREET ADDRESS CITY STATE ZIP 1 J�P 1 FAX 02 t 602,E ____9 __oti v-kV�, LC-k e 1.irC3� :A c _ _ -- CONTACT NAME Marjan Javanmard I PHONE 650.477.6430 E-MAILmjavanmard@solarcity.com STREET ADDRESS 391 Foster City Blvd CITY,STATE,ZIP Foster City, CA 94404 FAX ❑OWNER 0 OWNER-BUILDER 0 OWNER AGENT 0 CONTRACTOR 0 CONTRACTOR AGENT 0 ARCHITECT 0 ENGINEER 0 DEVELOPER 0 TENANT CONTRACTOR NAME LICENSE NUMBER LICENSE TYPE BUS.LIC# SolarCity Corporation 833104 C10 23340 COMPANY NAME SolarCity Corporation E-MAIL mjavanmard@solarcity.com FAX STREET ADDRESS CityCITY,STATE,ZIP PHONE 391 Foster Blvd Foster City, CA 94404 650:477.6430 ; ARCHITECT/ENGINEERNAME. LICENSE NUMBER. BUS.LIC# COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE USE OF [`l SFD or Duplex ❑ Multi-Family PROJECT LN WILDLAND PROJECT EN STR .TURF: 0 Commercial URBAN INTERFACE AREA 0 Yes 0 No FLOOD ZONE 0 Yes 0 No ❑`SOLAR PANELS 0 ELECTRIC VEHICLE CHARGING STATION 0 SOLAR WATER HEP.TING0 OTHER: FOR SOLAR PANELS: NUMBER OF PANELS/UNITS: I 1 KILOWATTS(COMMERCIAL ONLY): et`T 9.... TOTAL VALUATION Gf 11 00(9-00 0 DESCRIPTION OF WORK Installation ( 11- ) rooftop flush mounted solar panel ('f.q 9 kW st }'Ve -L 3 W , I-*, . wv—,_,,eN S1C--- '\JtC t :9 e-0 RECEIVED BY: , .� By my signature below,I certify to each of the following: I am the pro/ertyer or authorized agent to act on the property owner's behalf. I have read this application and the information I have provided is correct. I have rea. he P e ription of Work and verify it is accurate. I agree to comply with all applicable local rn ordinances and state laws relating to building construction. I autho'"-re.."entatives of Cupertino to enter the above-identified property for inspection purposes. Signature of Applicant/Agent: Date: G / i SUPPLEMENTA "+FORMATION REQUIRED oFFIcE USE ONLY - E] VSOVER-TRE-COUNTER ❑ EXPRESS 41U F;10 0 STANDARD r0 LARGE 0 iii MAJOR - __. __..,.---- _. .- PYApp 2011,doc revised 03/16/11 CITY OF CUPERTINO )6(Dq0135, 4 FEE ESTIMATOR—BUILDING DIVISION 13,9 ADDRESS: 21820 Dolores Ave DATE: 09/21/2015 REVIEWED BY: PAUL I icP"1 APN: 359 18 004 BP#: *VALUATION: $9,000 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Addition SFD or Duplex PENTAMATION USE. PERMIT TYPE: SOLAR-RES WORK Install (N) rooftop solar PV- 17 Panels(4.42 KW) and Install (N) 125 Amp Main Service Panel SCOPE Mech. Plan Check I I Plumb.Plan check I Elec.Plan Check 0.0 hrs $0.00 Medi Permit Fee: Plumb.Permit Fee: Elec.Permit Fee: lEPERMIT Other 4lech Ins!) I-1 Other Plumb Insp Other Elec.Insp. 1-3.,71 hrs $48.00 liech Imp Fee: Plumb, Inv. Fee: Flee.Imp. lee: NOTE:This estimate does not include fees due to other Departments(Le.Planning,Public Works,Fire,Sanitary Sewer District,School District,etc.). These fees are based on the preliminary information available and are only an estimate Contact the Dept for addn'l info. FEE ITEMS(Fee Resolution 11-053 Eff 7/1/13) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 I 1 I # Alternative Energy System Suppl.PC Fee: to Reg. 0 OT 0.0 hrs $0.00 $236.00 IPHOTOVRES Photovoltaic System PME Plan Check: $0.00 I 125 I amps Electrical Permit Fee: $0.00 $48.00 1BELEC200 Services Suppi.Insp.Fee: Reg. 0 OT 0.0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $48.00 Construction Tax: Administrative Fee: 1ADMIN $45.00 7 Work Without Permit? 0 Yes c) No $0.00 Advanced Planning Fee: $0.00 Select a Non-Residential Building or Structure 0 Travel Documentation Fee: 1TRAVDOC $48.00 / ,4 Strong Motion Fee: 1BSEISMICR $1.17 Select an Administrative Item / Bldg Stds Commission Fee: 1BCBSC $1.00 SUBT:QTATSt:, $143.17 $284.00 TOTALFEE. $427.17 Revised: 07/02/2015 WATER-CONSERVING PLUMBING FIXTURES %/ OWNER CERTIFICATE OF COMPLIANCE 44,4j,�y COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION CUPERTINO 10300 TORRE AVENUE •CUPERTINO,CA 95014-3255 (408)777-3228•FAX 408)777-3333• }uildinq1(a) bcupertino.orq �,I O 0 )?f cg Owner Name SR LrKS)I M I J. NU L I I fl L Pr Permit No. Address . • I _ti IV' .r. 0s 0 Q 1. Is your real property a registered historical site?i ❑ Yes Civil Code Sections 1101.1 through 101.8 do not apply. Skip the rest of the form and sign bottom of form. XI No Gd to Question 2. 2. Does your real property have a licensed plumbe certifying that,due to the age or configuration of the property or its plumbing,installation of water-conserving phu bing fixtures is not technically feasible? ❑ Yes Civil Code Sections 1101.1 through 101.8 do not apply. 0 The licensed plumber's certifica on has been provided to the Building Division. Skip the rest of the form and sign bottom of form. $ No Go to Question 3. 3. Is water service permanently disconnected for your building? O Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. No Go to Question 4. 4. Is your real property built and available for use r occupancy on or before January 1, 1994? ❑ No . My real property is built and availabl for use or occupancy after January 1, 1994. Civil Code Sections 1101.1 through 101.8 do not apply. Skip the rest of the form and sign bottom of form. g Yes My real property is built and availab e for use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 101.8 apply. Check one of the three following statements and sign bottom of form.. 5. Please check ONE of the following: X My property is a single-family residential rea property. See Civil Code Section 1101.4. On and after January 1, 2014, building alter tions or improvements shall require all non-compliant plumbing fixtures to be replaced with water-conserving plumb' g fixtures throughout the building.On or before January 1,2017,all non- compliant plumbing fixtures shall be replced with water-conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements). 0 My property is a multifamily residential real-property. See Civil Code Section 1101.5. On and after January 1, 2014,specified building alterations or improvements shall require non-compliant plumbing fixtures to be replaced with water-conserving plumbing fixtures. On or before January 1, 2019,all non-comph�t plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building(regardless of whether property undergoes alterations or improvements). 0 My property is a commercial real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non-compliant plumbing fixtures to be replaced with water- onserving plumbing fixtures. On or before January 1, 2019, all non-co pliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building(regardless of whether property undergoes alterations or improvements). I,as the owner or owner's agent of this property certify under penalty of perjury that non-compliant plumbing fixtures will be replaced prior to date specified above with wate-conserving plumbing fixtures in accordance with Civil Code Sections 1101.1 through 1101.8,the current California Plumbin Code and California Green Building Standards Code,and manufacturer's installation requirements,and that the water-con erving plumbing fixtures comply with the requirements as indicated in the table on the following page. Owner or Owner Agent's Signature: '�° ---� Date: Upon completing and signing this Certificate, lease return it to the Building Division in order to final your building permit. SB407 2015.doc revised 08/26/15 W - I " WA* KE / CARBON MONOXIDE ALARI'�.oS OWNER CE :TIRACATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION CUPERTINO 10300 TORRE AVENUE•CUPERTINO, CA 95014-3255 (408)777-3228• FAX(408)777-3333• buildinci cupertino.orq �y I Permit No. 15 10 O I Address 2 J b-.O �0 LD R. A-VeNVe #of Alarms Smoke: 5 Carbon Monoxide: C.VP,roImo c1 0 (4_ PERMIT CAN T BE FINALED AND COMPLETED UNTIL THIS CERTIFICATE HAS BEEN SIGNED AND RETURNED TO THE BUILDING DIVISION PURPOSE This affidavit is a self-certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R314, 20113 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single-family and multi-family dwellings shall be provided with Smoke Alarms and Carbon. Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds $1000.00, CRC Section R314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations: AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of the X X bedroom(s) On every level of a dwelling unit including basements X X Within each sleeping room X Carbon Monoxide alarms are not required in dwellings which do not contain fuel-burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. Power Supply:In dwelling units with no commercial power supply, alarm(s)may be solely battery operated. In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceilingifinishes or there is no access by means of attic,basement or crawl space. Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2.An electrical permit is required for alarms which must be connected to the building wiring. As owner of the above-referenced property, I hereby certify that the alarm(s) referenced above has/have been installed in accordance with the manufacturer's instructions and in compliance with the California Building and California Residential Codes. The alarms have been tested'and are operational, as of the date signed below. I have read and agree to comp) with the terms and conditions of this statement Owner(or Owner Agent's)Name: Si nature Contractor Name: Signature) Lic.# Date: Smoke and CO form.doc revised 03/18/14 ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID-INTERTIED VIA A FLASHING WILL BE PAINTED TO MATCH EXTERIOR AC ALTERNATING CURRENT UL-LISTED POWER-CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. PLOT PLANS CHECKED B'Y CONC CONCRETE 3. A NATIONALLY-RECOGNIZED TESTING ' OA"- DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN DATE ��a /2_0I,S EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. COMMUNITY DEVELOPMENT DEPARTMENT PLANNING DEPT (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING BUILDING DIVISION - CUPERTINO EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, APPROVED CUPERTINO FSB FIRE SET-BACK A SIGN WILL BE PROVIDED WARNING OF THE This set UI laps and s GALV GALVANIZED HAZARDS PER ART. 690.17. P pecifications MUST be kept at the GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE job site during construction. Itis unlawful to make any GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY changes or alteratidns on same, or to deviate HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. therefrom,without approval from the Building Official, I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL The Stamping of this plan and specifications SHALL NOT Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). be held to permit or to be an approval of the violation Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER of an ovisions of a'ny,'�Ci�ty qrdinance or State Law, kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR BY "a__ 0 t�.Mt�J.11r�V kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC DATE rirli 0 *1 LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). PERMIT MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN I © CUPERTINO • (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY ��V Building Department NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE ` ' SEP 21 2015 OC ON CENTER UL-LISTED LOCATION PROVIDED BY THE -` PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING REVIEWED FOR CODE COMPLIANCE POI POINT OF INTERCONNECTION HARDWARE. �� PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE Reviewed By: SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY • V VOLT O . r'' E L. pY Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT - _, 11 .1!--- I 14 a'• ,; .J - PV1 COVER SHEET 3R NEMA 3R, RAINTIGHT z . ,.. " ,lrha PV2 SITE PLAN ll® • PV3 STRUCTURAL VIEWS # r n,T ►, ,;i : - PV4 UPLIFT CALCULATIONS LICENSE GENERAL NOTES + '', w- . PV5 THREE LINE DIAGRAM 4 ' �` `` R. 9I' Cutsheets Attached 1. ALL WORK TO BE DONE TO THE 2013 �' r • ' H __ CA # 888104 .� * mow-+ ; ? * , C-10 CALIFORNIA BUILDING CODE AND THE 2013 11 - ' ' -.1 ,' * 'a'ra t -� , CALIFORNIA RESIDENTIAL CODE. • `�' A� - _ , - , RECEIVED 2. ALL ELECTRICAL WORK SHALL COMPLY WITH = moi' - :, = `-'- : - ` l'" .1'." ` 7.ri-: THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY ' sgy �f _ ' - -- . - t =THE 2013 CALIFORNIA ELECTRIC CODE. ' fib_. i .i .�� ._: '' _ cE? 2 1 2015 MODULE GROUNDING METHOD: * '�^�' y T t "`., ` "' _-� •� rr.""AHJ: Cu ertino • ,, ( 11REV BY DATE COMMENTS p 'F* � r . ' I ��DATE COMMENTS ; , UTILITY: Pacific Gas and Electric Company ! j `� ,�`� F ©©© Di 1 O ,1i�e4 _, . Geological Suri 1L S1 A Fan ency ©©© J 3—9 5 0 5 8 2 0 0 0 PREMISE ONNER: DESCRIPTION: DESIGN: CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: \ ,' SolarCity, CONTAINED SHALL NOT BE USED FOR THE SRINIVASA MURTHY SRINIVASA RESIDENCE Ellaine Comilang BENEFIT OF ANYONE EXCEPT SOLARCITY INC.. MOUNTING SYSTEM: �•'� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN CompMount Type C 21820 DOLORES AVE 4.42 KW PV ARRAY ►I' PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES: CUPERTINO, CA 95014 3055 Clearview Way ORGANIZATION, EXCEPT IN CONNECTION WITH7��M TMK OWNER: THE SALE AND USE OF THE RESPECTIVE (17) REC # REC26OPEZ Affi N: * PAGE NAME: SHEET: REV: DATE San Mateo, CA 94402 T29 SOLARCITY MEET,SOLARCITY INC. THE WRITTEN INVERTER: 4082043059 PV 1 8/11/2015 (888)(SOL—OTY(765-2489)650) Swww.6solardty.com FRONIUS ; Primo 3.8 COVER SHEET PITCH: 25 ARRAY PITCH:25 ' MP1 AZIMUTH: 180 ARRAY AZIMUTH: 180 MATERIAL: Comp Shingle STORY: 1 Story CUPERTINO 1.#,' Building Department Front Of House ,7 1 SEP 21 2015 R=VIEWED FOR CODE COMPLIANCE Reviewed By: a - 0 0 LEGEND ® (E) UTILITY METER & WARNING LABEL 3' FSB \ _ ® INVERTER W/ INTEGRATED DC DISCO �r �� & WARNING LABELS — _3'FSB❑ — — —3'FSB— DC DC DISCONNECT & WARNING LABELS O t MP1 ' o o c® �-1 AC DISCONNECT & WARNING LABELS 0 3 0 0 — C W m DC JUNCTION/COMBINER BOX & LABELS 71 o 3 0 0 c iL W Fo 0 DISTRIBUTION PANEL & LABELS ' o s 0 0 • )8( 1 0 0 C LOAD CENTER & WARNING LABELS LG 0 c 3 O M DEDICATED PV SYSTEM METER A 0 STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR ® CONDUIT RUN ON INTERIOR GATE/FENCE 0 HEAT PRODUCING VENTS ARE RED re7. 11 ;I INTERIOR EQUIPMENT IS DASHED L=J SITE PLAN N TOTAL ARRAY AREA (SF): 308 - TOTAL ROOF AREA (SF): 3968 Scale: 3/32" = 1' W " E TOTAL ARRAY AREA IS a7.77 O i' 10' 21' PERCENT OF TOTAL ROOF AREA ' ,! '!!!' s PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION USED FORHERHIN JOB NUMBER: J 3-9505820 00 SRINIVASA, MURTHY SRINIVASA RESIDENCE g CONTAINED SHALL NOT FO USED THE Ellaine Comilan �\'!SolaiCity BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount T e C21820 DOLORES AVE 4.42 KW PV ARRAY �Q. PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES C U P E R TI N 0, CA 95014 THE SALE AND USE OF THE RESPECTIVE (17) REC # REC260PEZ 3055 ew Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV: DATE San Mateo, CA 94402 PERMISSION OF SOLARCITY INC. INVERTER: 1(650)638-1028 F:(650)638-1029 FRONIUS # Primo 3.8 4082043059 SITE PLAN PV 2 8/11/2015 (888)—SOL—CITY(765-2489)www.salaraity.aam .10111.1.1.11.1)(11141 2x6 DF#2 (N) ///////� 3'-6't i 011.1 6" END Si DISTANCE '� X .�' 6"��16" O.C. TYP.— r (E) 2x6 RAFTER I ga, —•* 14'-5" - - -i 7' / 234"r o 0 _ — o — o i,____.. 4" --11- CI H (E) LBW N SIDE VIEW OF MP1 NTS SISTER UPGRADE INFORMATION. RAFTER UPGRADE INDICATED BY HATCHING SIMPSON SDW WOOD SCREWS (N) 2x6 SIDE MEMBER J UPGRADE NOTES: MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES 1. CUT AND ADD (N) SISTER AS SHOWN IN THIS SIDE VIEW AND REFERENCED TOP VIEW. LANDSCAPE 72" 24" STAGGERED 2. FASTEN (N) SISTER TO (E) MEMBER W/SIMPSON SDW 22300 (IF 2-PLY) OR 22458 PORTRAIT 48" 20" (IF 3-PLY) SDW SCREWS AS SHOWN AT 16" O.C. ALONG SPAN AS SPECIFIED, IF 2x6 END FASTENER GROUPING RAFTER 2x6 @ 24"OC ROOF AZI 180 PITCH 25 STORIES:1 WOOD SPLITTING IS SEEN OR HEARD, PRE-DRILL WITH A j" DRILL BIT. D 1 ARRAY An 180 PITCH 25 Scale: 1"=1'-0" LI 2x6©16"OC Compp Shingle ALT. OPTION FOR FULL LENGTH MEMBERS ONLY- FASTEN (N) SDE MEMBER TO (E) RAFTER W/ 10d (IF 2-PLY) OR 16d FROM EACH SIDE (IF 3-PLY) COMMON CUPERTINO NAILS AT 6" O.C. ALONG SPAN. r,. f� •SISTER ALL RAFTERS ON THIS MP SECTION INTO WHICH THE ARRAY IS LAGGED Building Department ,/AN1 SEP 21 2015 REVIEWED FOR CODE COMPLIANCE PV MODULE Reviewed By: 5/16" BOLT WITH LOCK r INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT HOLE. (E) WALL OR i (E) RIDGE BOARD ZEP ARRAY SKIRT (6) -±7- SUPPORT BELOW r OR SUPPORT BELOW (E) RAFTER -� SEAL PILOT HOLE WITH (E) PURLIN OR MID SUPPORT ZEP COMP MOUNT C (4) -- (�) POLYURETHANE SEALANT. +- c w� - -- =v�i�io�iii.� � -.IMF A!iiioiooi�vii ii `� 3 INSERT FLASHING. ZEP FLASHING C ,41EM'r& L )) --ili-- 1 - SIMPSON SDW 22300 it (N) SISTER MEMBER CENTERED + I„-� ,; _ R:- WOOD SCREWS OVER MID SUPPORT (E) COMP. SHINGLE � - 4'-0"-- / 4'-0” (4)) PLACE MOUNT. (E) ROOF DECKING 4&Mli . i DI D1 5/16" DIA STAINLESS (5) (5)----___ SSE L INSLGGALING WAASHSHT WITH EER. W MIRW STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH WITH SEALING WASHER ( ) BOLT Sc WASHERS. U1 TOP VIEW OF PARTIAL SISTER OVER SUPPORT (2-1/2" EMBED, MIN) Scale: 3/4"=1'-0" (E) RAFTER STANDOFF $ i Scale: 1 1/2" = 1' CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: J 3-9505820 00 PREMISE OWNER: DESCRIPTION: DESIGN:SRINIVASA, MURTHY SRINIVASA RESIDENCE Ellaine Comilang �\`I! w CONTAINED SHALL NOT BE USED FOR THE �olarCIt_ BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: Y NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 21820 DOLORES AVE 4.42 KW PV ARRAY �� 'I,\ PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: CUPERTINO, CA 95014 THE SALE AND USE OF THE RESPECTIVE (17) REC # REC260PEZ 3055 Clearview Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN ateo, CA 94402 INVERTER: PAGE NAME: SHEET: REV: DATE SonT:(650)638 110288 F:(65)638-1029 PERMISSION OF SOLARCITY INC. FRONIUS # Primo 3.8 4082043059 STRUCTURAL VIEWS PV 3 8/11/2015 (888)-SOL-CITY(765-2489)www.solarcity.cam UPLIFT CALCULATIONS 08.11.2015 i�COI�rC + / PV System Structural Version#48.9 1/4.1 YD Desian Software Project Information &Table Of Contents Risk Category: II PV System Type SolarCity SleekMount'" Comp Roof Comp Roof Layers of Comp Roofing 2 Roof Slope 25° Rafter Spacing 24"O.C. PV System Module Orientation Landscape and Portrait PV Module Area 302 sf PV Module Width 39" PV Module Length 66" Standoff(Attachment Hardware) Comp Mount Type C Reduced Ground/Roof Live/Snow Loads Ground Snow load pg 0.0 psf ' ASCE Table 7-1 Surrounding Roof Snow 0.0 psf 'ASCE Eq:7.4-1 Roof Snow Over PV Modules 0.0 psf 'ASCE Eq:7.4-1 ,c\__``'_Oe" V� a,e Wind Design Criteria �.` '06) Wind Design Code ASCE 7-10 V Wind Design Method Partially/Fully Enclosed Method J\d�� G� Basic Wind Speed V 110 mph ' Fig.26.5-1A ' %t \P� Exposure Category C ' Section 26.7 \1 Q\ Roof Style Gable Roof 'Fig.30.4-2A/8/C-SAIB O Mean Roof Height h 15 ft Section 26.2 STI/Y. G' Q 6 ��G Effective Wind Area(1 Module) A 17.8 sf IBC 1509.7.1 h% %4 J GO Wind Pressure Calculation Coefficients y Q� Wind Pressure Exposure Kz 0.85 Table 30.3-1 1f Topographic Factor Kzt 1.00 Section 26.8 , �-'' >2 Wind Directionality Factor Kd 0.85 Section 26.6-1 J\C. e�6 Importance Factor I NA � eJ� Velocity Pressure qh qh=0.00256(Kz)(Kzt)(Kd)N^2) Equation 30.3-1 22.4 psf Ext.Pressure Coefficient(Up) GCp(Up) -0.88 Fe.30.4-2A/BIC-5A/B Ext.Pressure Coefficient(Down) GCp(Down) 0.45 Fay.30.4-2A/13/C-5AM Design Wind Pressure p p=qh(GCp) Equation 30.4-1 Wind Pressure Up p(up) -19.6 psf Wind Pressure Down p(down) 16.0 psf Allowable Standoff Spacings X-Direction V-Direction Max Allowable Standoff Spacing Landscape 72" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trlb 20 sf PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at Standoff T-actual -197 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity DCR. 39.4% Max Allowable Standoff Spacing Portrait 48" 66" Max Allowable Cantilever Portrait 20" NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area Trib 22 sf PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at Standoff T-actual -221 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity DCR 44.2% CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: J 3-9505820 00 PREMISE OM ER: DESCRIPTION: DESIGN:SRINIVASA, MURTHY SRINIVASA RESIDENCE Ellaine Comilang "4\`f! � CONTAINED SHALL NOT E USED FOR THE /i�;�OlC11�'�_ _ BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: 21820 DOLORES AVE Y NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type c 4.42 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES C U P E R TI N 0, C A 9 5014 THE SALE AND USE OF THE RESPECTIVE (17) REC # REC260PEZ 3055 Clearview Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE Mateo, FA 9442 T:(650)638-1028638-1029 PERMISSION OF SOLARCITY INC. FRONIUS # Primo 3.8 4082043059 UPLIFT CALCULATIONS PV 4 8/11/2015 (888)-SOL-CITY(765-2489)www.solarcity.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECSMODULE SPECS LICENSE _ • BOND (N) #8 GEC TO (N) GROUND ROD Panel Number: Inv 1: DC Ungrounded INV 1 —(1)FRONIUS # Primo 3.8 LABEL: A —(17)REC ## REC260PEZ CA # 888104 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:1005905794 AFC' Inverter; 3800W, 240V, 97%, w/ Antenna PV (nodule; 260W, 236.6W PTC, MC4, 40mm, Black Frame, ZEP Enabled C-10 Underground Service Entrance INV 2 Voc: 37.8 Vpmax: 30.7 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER (N) 125A MAIN SERVICE PANEL (N) 100A/2P MAIN CIRCUIT BREAKER Inverter 1 IND 100A/2P 30 FRONIUS Q DC+ Primo 3.8 a. DC- MP1: 1x9 r , (E) LOADS \ 1 — t • /1 Li 2aav r L2 I • I •� DC+ I N �� DC- I RDC+Il I' 20A/2P EGC/ .� DC+ C111 A GEC la -�� DGrGMP1: 1x8n III � • _ B Imum ---—EGC— — \t— — GC I (1)Conduit Kit; 3/4" EMT N J_ _ I EGC/GEC j - Z-Z---- ---- CD GEC TO 120/240V I SINGLE PHASE i CUPERTINO IIII DepartmentUTILITY SERVICE SEP 2 2015A -/-,'` W �REVIEReviewedByCBu�E NCE Voc* = MAX VOC AT MIN TEMP POI (1)Ground Rod; 5/8" x 8', Copper ^ H DC (1)AWG #10, THWN-2, Black I (2)AWG#10, PV Wire, 600V, Black Voc* =370.51 VDC Isc =9.01 ADC O TI-(1)AWG #10, THWN-2, Red O 6T_(1)AWG #10, Solid Bare Copper EGC Vmp =276.3 VDC Imp=8.5 ADC -� (1)AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=15.8 MC 666 (1)Conduit Kit; 3/4" EMT -(1)AWG #8, THWN-2, Green EGC/GEC-(1)Conduit Kit; 3/4" EMT 2 (2)AWG #10, PV Wire, 600V, Block Voc* =329.34VDC Isc =9.01 ADC 0 c4-(1)AWG #10, Solid Bare Copper EGC Vmp =245.6 VDC Imp=8.5 ADC (1)Conduit Kit; 3/4" EMT CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: JB-9505820 00 PREMISE OWNER: DESCRIPTION: DESIGN: ` `,CONTAINEDO SHALL NOTE CBEE TSED FOR THESRINIVASA, MURTHY SRINIVASA RESIDENCE Ellaine Comilang SolarCity BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 21820 DOLORES AVE 4.42 KW PV ARRAY �' 4. /��� PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES CUPERTINO, CA 95014 SALE ALE AND USE OF THE RESPECTIVE (17) REC # REC260PEZ 3055 Clearview Way THESOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE San Mateo, CA 94402 PERMISSION OF SOLARCITY INC. INVERTER: T:(650) # Primo 3.8 4082043059 THREE LINE DIAGRAM PV 5 8/11/2015 (888)(sa,aTTY 638-1028 76582489)www rcciitycom WARNING:PHOTOVOLTAIC POWER SOURCE Label Location: Label Location: Label Location: (C)(IC)(CB) PV SYSTEM (AC) WARNING (DC)(INV)(CB) Per Code: DISCONNECT FOR Per Code: CRC R331.2 UTILITY OPERATION ELECTRIC SHOCK HAZARD CEC 690.35 F THE DC CONDUCTORS OF THIS ( ) Label Location: PHOTOVOLTAIC SYSTEM ARE TO BE USED WHEN PHOTOVOLTAIC DC (DC) (INV) UNGROUNDED AND INVERTER IS MAY BE ENERGIZED DISCONNECT Per Code: UNGROUNDED CEC 690.14.C.2 Label Location: WARNING (DC) Per Code: ELECTRIC SHOCK HAZARD Label Location: DO NOT TOUCH TERMINALS CEC 690.17 MAXIMUM POWER-_ (DC) (INV) TERMINALS ON BOTH LINE AND POINT CURRENT(Imp) A Per Code: LOADIN THEOPEN POSSIDES MAY BE ITION IZED MT VOLTAUMGE E(V p) V CEC 690.53 POINT VOLTAGE Vm MAXIMUM SYSTEMv VOLTAGE(Voc) SHORT-CIRCUIT A CURRENT(Iso) Label Location: WARNING (P01) PER-T1140 Per Code: INVERTER OUTPUT ``d1�g DePaCtIll ent CONNECTION CEC 705.12.D.7 7; Label Location: DO NOT RELOCATE t)>\; i/- WARNING (DC) (CB) THIS OVERCURRENTD ^� EP 2 ZOiS DEVICE Per Code: ,� ,,.;; t ,PNCE ELECTRICAL SHOCK HAZARD `� Co�E Gpiv1P1- DO NOT TOUCH TERMINALS CEC 690.17 G TERMINALS ON BOTH LINE AND \j`JECti FQR �%, ,�,( LOAD SIDES MAY BE ENERGIZED R �1E IN THE OPEN POSITION Label Location: Re41ewed BY DC VOLTAGE IS PHOTOVOLTAIC POINT OF (POI) ALWAYS PRESENT WHEN INTERCONNECTION Per Code: SOLAR MODULES ARE WARNING: ELECTRIC SHOCK EXPOSED TO SUNLIGHT HAZARD. DO NOT TOUCH CEC 690.54; CEC 690.17 TERMINALS.TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE Label Location: DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. WARNING (INV) PV POWER SOURCE Per Code: MAXIMUM AC ELECTRIC SHOCK HAZARD OPERATING CURRENT - A CEC 690.5C IF A GROUND FAULT IS INDICATED 690.5(C) NORMALLY GROUNDED MAXIMUM AC CONDUCTORS MAY BE OPERATING VOLTAGE V UNGROUNDED AND ENERGIZED Label Location: Label Location: CAUTION (D) (P01) PHOTOVOLTAIC AC (AC) (P01) Per Code: (AC): AC Disconnect DISCONNECT CIRCUIT IS BACKFED Per Code: PHOTOVOLTAIC SYSTEM CEC 690.64.B.4 (C): Conduit CEC 690.14.C.2 (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit Label Location: Label Location: _ A (AC) (P01) (P01) (INV): Inverter With Integrated DC Disconnect MAXIMUM AC CAUTION (LC): Load Center OPERATING CURRENT Per Code: DUAL POWER SOURCE Per Code: MAXIMUM AC SECOND SOURCE IS (M): Utility Meter OPERATING VOLTAGE _ V CEC 690.54 PHOTOVOLTAIC SYSTEM CEC 705.12.D.7 (P01): Point of Interconnection CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR `b f/1, 3055 Clearview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED •- ■ San Mateo,CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, Label Set l�+�� T:(650)638-1028 F:(650)638-1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE �� �f� ' � (888)-SOL-CITY(765-2489)www.solarcity.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. �r 0 "rSoiarCity ZepSolar Next-Level PV Mounting Technology ''''SOIarCity Zep Solar Next-Level PV Mounting Technology IPZep System Components for composition shingle roofs iii. ,..,.7 �ri Q�gVieQa. Ground Zep —, .. '" - Interlock :trey si3±taawnl t,,°'~ \�(S\\ -.. Leveling Foot I _a- _.».., .__ (.10\iG� 1%13 \ix6prifsd Zep C mpetlbl PV Module - w I..19",:,..%%.,. '..)f -') lOr r 41. '' `" Zep Groove >" Reef Attachment eJ Anay5 Irl - - 7' - .` „„. Laildliall , ti *(0, Description ��®v • PV mounting solution for composition shingle roofs .� �`� ;� �l'x i� A0OMPPScs- • Works with all Zep Compatible Modules ti �% 'tpi �� • Zep System UL 1703 Class A Fire Rating for Type 1 and Type 2 modules °` - ' Iii • Auto bonding UL-listed hardware creates structual and electrical bond ®LISTED Comp Mount Interlock Leveling Foot Part No.850-1345 Part No.850-1388 Part No.850-1397 Listed to UL 2582, Listed to UL 2703 Listed to UL 2703 Specifications Mounting Block to UL 2703 (Ili • Designed for pitched roofs Installs in portrait and landscape orientations ''i 11 In • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 ) bilk1 • Wind tunnel report to ASCE 7-05 and 7-10 standards �l ` t • Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467 �� 4 iq�, .� ; • Zep System bonding products are UL listed to UL 2703 ,\J r �1� • Engineered for spans up to 72"and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices Ground Zep Array Skirt,Grip,End Caps DC Wire Clip • Attachment method UL listed to UL 2582 for Wind Driven Rain Part No.850-1172 Part Nos.500-0113, Part No.850-1448 Listed to UL 2703 and 850-1421,850-1460, Listed UL 1565 ETL listed to UL 467 850-1467 zepsolar.com zepsolar.com Listed to UL 2703 This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of Zep Solar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. responsible for verifying the suitability of Zep Solar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. 12 22 14 ZS for Comp Shingle Cutsheet Rev 02.pdf Page: 1 of 2 12 22 14 ZS for Comp Shingle Cutsheet Rev 02.pdf Page: 2 of 2 k itrikli‘A. ENERGIZING LIFE TOGETHER ..,, REC REC PEAK ENERGY Z-LINK SERIES 65.55±0.1 1.38 _ 39 oz — EFFICIENCY HIGH PERFORMANCE YEAR PRODUCT WARRANTY SOLAR PANELS . YEAR LINEAR POWER ,, OUTPUT WARRANTY RE FD : AK B- - ------- - = a7.z4 04/7..,..4. *FR US IMPORT DUTY FREE — F.. ENERGY Dai wQ —�. IN a 1. I-I I — I TEMPERATURE RATINGS Nominal Opera ting Cell Temperature(Nc Ti 457°C(±7°C) r - __ -. ....._..--- - ------- —.....----- ------...._ v -- 1 Temperature Coefficient of P*.,�re -0.40%/'C I Temperature Coefficientof:I: � 0 27%/°C . ,7 Temperature Coefficient of h. 0.024%/°C - l' I ✓ ,i ' ' 1 i All measurements in inches ELECTRICAL DATA@STC REC26OPEZ GENERALDATA Nominal Power-Prp(Wp) 260 CellType: BORECPEmu(ti-crystalline 3stnn s'c:1 ass diodes 1.( _� i'� �, f t .-" ., WattClassSorting(WP) /-� g YP Nominal Power Voltage-VMpp(V) 30.7 Glass: 0125 in solar glass with anti-re lection r.` surface treatment Nominal Power Current-I (A) 8.50 Mw Backsheet: Double layer highly reslotantpolyester Open e V (V) 378 .'• P g « Fane Anodized aluminum(black) Short Circuit Current-Isc(A) 9.01 Zep Groove compatible Panel Efficiency(%) 15.8 Junction Box 0:156in(12AW6)solarcahle.2 IP67 atei The electrical characteristics are within+/-10%of the indicated values oflr,V,and PMP,at standard Test conditions(STC). Connectors N4 Am henol 0Mpq _ 4 Values at standard test condit ons STC(airreass AM 1.5,irradiance 1000 W/m',cell temperature 77°F(25°C)) P '4!4 G ��{ At low irradiance of 200 W/m (AM 1.5&cell temperature 77°F(25°C))at least 97%of the STC panel efficiency will be achieved. Origin. Made in Singapore Nr 44.,. '.-'4'*- • / ELECTRICAL DATA @ NOCT REC26OPEZ MAXIMUM RATINGS '. s"s ' Nominal Power-P W 197 Operational Temperature 40_+185°E 40_+85°C) C'0MPO'\ <'; Nominal Power Voltage-VMpp(V) 290 Maximum System Voltage. 1000VUL Nominal Power Current-IMpp(A) 681 Design Load: 50 lbs/ft 2(2400 Pa)long side ?:." MORE POWER COMPATIBLE WITH M Open Circuit Voltage-Va(V) 35.7 30165/ft`(1436 Pa)short side PER FT ZEP GROOVE FRAME a Short Circuit Current-Isc(A) 724 Max Series Fuse Rating- 15A 1 Nominal operating cell temperature NOCT(800 W/m',AMIS.windspeed Im/s,ambient temperature 68°F(20°C). Max Reverse Current: ISA ast OGrj. c;; CERTIFICATION ..,1'..RA"TY MECHANICAL DATA T • �``F' 1,: • O 10 year product warranty. Dimensions: 65.55 x39 02 x 1.57 in(1665 x 991x 4016m) ON�L us 25 year linear power output warranty Area 17.75ft2(1.65m2 US IMPORT EASY TO LISTED (max.degression in performance of 0.7%p.a.). ) DUTY FREE INSTALL f; Weight 43165 19.5k +, UL 1703,Fire rating:Type 1,Class C g ( g) V .�'. Note! All given specifications are subject to change 41r ..4,-,. without notice atany time. 'y,a, r/y y,J r^, f REC is a leading global provider of solar energy solutions. With more than 15 years of experience,we offer sustainable,high performing' products,services and investments for the solar industry. Together with our partners,we create value by providing solutions that better REC meettheworld'sgrowingenergyneeds.REC is headquartered inNorwayandlistedontheOsloStockExchange(ticker:REC50L).Our1,600 1/11/11' ‘16.. employees worldwide generated revenues of USD 647 million in 2073. www.recgroup.com 1• 1 CUPERTINO ,/��/ Building Department - N SEP 21 2015 Ail REVIEWED FOR CODE COMPLIANCE Reviewed By: C/! G /Perfect Welding/Solar Energy/Perfect Charging TECHNICAL DATA FRONIUS PRIMO Ifi—onius SHIFTING THE LIMITS INPUT DATA PRIMO 3.8-1 PRIMO 5.0-1 PRIMO 6.0-1 PRIMO 7.6-1 PRIMO 8.2-1 .,, u,alyd A I yr ikN'tQ il) G.0 6AC -1 U - �,�, t o "1 lVV qI i l7 AVA FRONIUS PRIMO I,S IbS Ih:S Ib,S I,:A..>.,A I`,,;I,.-A I,.A IaA LtI UC. ,.t a�:, AI:isalms sleulc Olt(MIMIC 2r22.i,1 /The future of residential solar is here-Introducing the new Fronius Primo. .. r,, t tuba ,v, nloe.mpu t."ul,a,c 600 A' (—Tr) iiipul c ;1117• I-.,v 1'.,C N -_1'l\`' 0,1 1 I ,<„,,,v,„,ci,c IXC r_ _ •• ^� _ X \I11\ , IJ IFII V 'af) iTC)V 'V=J-I�s�V -.7 la l\" I.>l]aw ._ . a - ' 1)-11 >ae�vsse.mw — _ ,\ 5 Mak ` • d,....., v �. ..- ,` r 1 � _ /PChorn 0 /SnapINverter /Wi-Fiel /SuperFl /5n,art Grid /Arc Fault Circuit. ' a replacement process mouuung system interface llebIgIt Ready Inlermptmd, -�---> ' .. .. OUTPUT DATA PRIMO 3.8-1 PRIMO 5.0-1 PRIMO 6.0-1 PRIMO 7.6-1 PRIMO 8.2-1 /With power categories ranging from 3.8 kW to 8.2 kW, the transformerless Fronius Primo is the ideal compact v .,,,11,01 N,,,,r 20. i;',(.0 W -4000 W 4e,00 7v single-phase inverter for residential applications.The sleek design is equipped with the SnapiNverter hinge mounting ° ,,,`\ system which allows for lightweight,secure and convenient installation and service. 24,.o n 1:4,,,J1,1141,1 rl(/r 1'I)\CI,rcf„,ir, 211-4'; _S,\ 10, 47..\ '.5U;\ 700 /The Fronius Primo has several integrated features that set it apart from competitors including dual powerpoint 210 20A ;0.4 '5A 10 40 trackers,high system voltage,a wide input voltage range and unrestricted use indoors and outdoors.Other standard NI 1 .r-omy nu features include a Wi-Fi*and SunSpec Modbus interface for seamless monitoring and datalogging,Arc Fault Circuit (:1' 11141,14, 240 > 0'-7 a 1011 Interruption (AFCI), and Fronius's superb online and mobile platform Fronius Solar.web. The Fronius Primo is "`a'53 we c Gnd conneUim, tun i 244 designed to adjust to future standards,offering a complete solution to code restrictions and technical innovations of I,rr ou rI, tomorrow.It also works seamlessly with the Fronius Rapid Shutdown Box for a reliable NEC 2014 solution. r,1 I n,,,,,r dsmrt;olt Power factor(cos 4p,,r.4) 0.8 5-I Ind/rap TECHNICAL DATA FRONIUS PRIMO GENERAL DATA STANDARD WITH ALL PRIMO MODELS U ,Irsl Ilh s i.,,i.t,dcpti. I1 x24.7.5.117. Vlt 44,1,1 17.291b. I) Ir, t I F \ \711\ „n I,� i. CUPERTINO fj '3uildina Department Cc a cc 11 111 a I:cl 1 outdoor , 4e,_„ , �44'��' � 1� SEP 21 2015 I l l,. , 0 100 . ���^ 0.111. d ,,,,da,U, III 11 I;t, I)l* I Irl I ,111 , 11,1 I 1 .1S P„11, r15,11 REVIEWED FOR CODE COMPLIANCE -r la t 1J/,xlt,NEC Ar„cic 110 t 22 2No, 1071-111{Sc t 1 u 001 ULI6971 la_„e 2 21113,CSA 1IL 51 07 1,,,oe.1,20i3 ave - - I,eu„= ). Reviewed By: PROTECTIVE DEVICES STANDARD WITH ALL PRIMO MODELS Al(1A 2 11 NL( IN rdy L- c ul, t t,1,N III I -4114,14iJo,11c4r lc 4- AIP 1 /Perfect Welding/Solar Energy/Perfect Charging 1,. WE HAVE THREE DIVISIONS AND ONE PASSION:SHIFTING THE LIMITS OF •SSIBILITY. /Whether welding technology,photovoltaics or battery charging technology—our goal is clearly defined:to be the innovation leader.With around INTERFACES STANDARD WITH ALL PRIMO MODELS 3,000 employees worldwide,we shift the limits of what's possible-our record of over 1,000 granted patents is testimony to this.While others progress \11 11'Id,,, .,,,i.Il A, ,,.I r1, I=02.I I b c.n r:.ces,(I,IL,,.1,.sl 1111 I::2I ,tr I°Im11 r,. i,,aI all,,,.111s step by step,we innovate in leaps and bounds.: tT:55v:alwa us ' ys done.The responsible use of our resources fortes the basis of our corporate policy c miL,Ir,,-I i mad c cts .,mot I 1 1:,l rcla-c,n,i.,I: ..-2S U,Is(4 4 441,11 RuJ,, 4,141 I 11,4111114c,,,1 USB Further information about all Fionius products and our lobaners and representatives can be found at www.fronius.eom 1250:2(N(i 1-.4,t o, , ,. I,,,\`,1.i'. I l+=„1,„c,l IDatalogger alld Wclnrrocr 1„clodcd ... Fronius USA LLC .The tern,Wi-Fi(r®is a registered trademark of the Wi-Fi Alliance. 6797 Fronius Drive Portage,IN 46368 USA Krv.5-_U-I S USA pv-support-usa@fronius.com www.fronius-usa.com