Loading...
15040047CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 10382 MIRA VISTA RD CONTRACTOR: POCO SOLAR PERMIT NO: 15040047 OWNER'S NAME: STANEK MICHAEL W AND CAROL 3345 KELLER ST DATE ISSUED: 04/07/2015 OWNER'S PHONE: 4082652311 SANTA CLARA, CA 95054 PHONE NO: (408) 970-0680 ❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL COMMERCIAL ❑ INSTALL (14) PANEL PV SYSTEM ON SFDWL 4.8 KW License Class ((", (y�_Z Lic. # � C't ���1� o Contractor ate I hereb rim that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Sq. Ft Floor Area: %'aluation: $29100 have and will maintain Worker's Compensation Insurance, as provided for by APN Number: 35702018.00 Oeeupa 11c! 1 ` Pe: Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYRMIT ISSUANCE OR to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, rTCALLED 180 DAYS FR INSPECTION. 45, costs, and expenses which may accrue against said City in consequence of the Issued by: Date: granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. ( ^� r (4/7A.5- RE -ROOFS - Signature Date l . Signature All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. ❑ OWNER -BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) I, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(a) should I store or handle hazardous I have and will maintain a Certificate of Consent to self -insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and ' I have and will maintain Worker's Compensation Insurance, as provided for by the Health & Safety Code, Scs 25505, 255 3, a 25534. C� Section 3700 of the Labor Code, for the performance of the work for which this Owner or authorized agen Date: l /• permit is issued. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's CONSTRUCTION LENDING AGENCY Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section Licensed Professional 9.18. Signature Date ALTERNATIVE ENERGY PERMIT APPLICATION a'A Ote COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building(a cupertino.org AE Q S j PROJECT ADDRESS (D Z M \J1 APN # S_� 3 (, 'v (o, 1 t, dA V✓ O14ERNAME S PH E-MAILlJ N X10 2(5 ca 00gV% I. r a►�Q e S ,Ma' STREET ADDRESSO (� ` r i CIS V STAQTE(ZjPI �O �� 9 � O I L FAX ` ///A111\ PHOA 3 1 . i d - 9 Z3 z CONTACT NAME I, _I evr 1 v33 E-MAIL i� O 01 Q r CoV►j STREET ADDRESS CITY, $ A Y� �ZO\ C l Cvex CA 9 So qVq'O�N- OS t ❑ OWNER ❑ OWNER -BUILDER ❑ OWNER AGENT ❑ CONTRACTOR % CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT LICENSE NUMBER 81 Q � ( / LICENSE TYPE( � / CONTRJJTORCN1''AME�� �� i BUS. LIC # Q% 1• NC rQr_COMPANY NAMECr C 1 E-MAIL I G1� ( UC A(,CO F � OS STREET ADDRESS STATE, ZIP C•9 gSoS� PHONE %1c8 97 -0( ARCHITECT/ENGrNEER NAME LICENSE NUMBER BUS. LIC # Sa C. Co C_ loy COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE USE OF XI SFD or Duplex ❑ Multi -Family PROJECT IN WILDLAND PROJECT IN STRUCTURE: ❑ Commercial URBAN INTERFACE AREA ❑ Yes 11 NO FLOOD ZONE ❑ Yes ❑ NO SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PANELS: NUMBER OF PANELSAJNITS: ILI KILOWATTS (COMMERCIAL ONLY): LI ^ , N/ TOTAL VALUATION: n vO G DESCRIPTION OF WORK I J S ` h oo vrr►� 0i s'o�� � J I -1r\V2 f ter- RECEIVED IM, - By my signature below, I certify to each of the following: I am the property owner or authorized agent to act on the property owner's e ave read this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to building constio . I authorize representatives of Cupertino to enter the above -identified property for inspection purposes. Signature of Applicant/Agent: Date: �1 S SUPPLEMENTAL INFORMATION REQUIRED 6FFICEUSE01\LY `2 : . ❑ OVER-THEUcbUNTER ' U F" � v ❑ .EXRR$SS � - Ui�;. U t ` _ ❑ LARGE ❑- M. O PVApp_201 Ldoc revised 03/16/11 CITY OF CUPERTINO UPF FCTTMATnR—RI111,11INf nIVIMON lec. Plan Check LteCII, Flee 01her 1'Iech. Insp irher Plumb Insp drier Llec. Insp. Li ,Meeh. Insp. free: r'htnib. Insp. Fee: hasp. hee: NOTE: This estimate does not include fees due to other Departments (i.e. vianning, iwtrc works, rue, aantrary newer —strict, aur— _ r__ L_ _J -. IL- -I-- »! ..*:.. ..:)oGlo .,d n o nnlu as oedmato. Cnatart tha AOnt for addn'l info. FEE ITEMS (Fee Resolution 11-053 Ef : 7f ,1,,13) ADDRESS: 10382 MIRA VISTA RD DATE: 04/07/2015 REVIEWED BY: MENDEZ APN: BP#: "VALUATION: 1$29,000 xPERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY SFD or Duplex p Suppl. PC Fee: Q Reg. Q OT PENTAMATION SOLAR -RES USE: $0.00 PERMIT TYPE: WORK INSTALL 14 PANEL PV SYSTEM ON SFDWL 4.8 KW SCOPE Permit Fee: lec. Plan Check LteCII, Flee 01her 1'Iech. Insp irher Plumb Insp drier Llec. Insp. Li ,Meeh. Insp. free: r'htnib. Insp. Fee: hasp. hee: NOTE: This estimate does not include fees due to other Departments (i.e. vianning, iwtrc works, rue, aantrary newer —strict, aur— _ r__ L_ _J -. IL- -I-- »! ..*:.. ..:)oGlo .,d n o nnlu as oedmato. Cnatart tha AOnt for addn'l info. FEE ITEMS (Fee Resolution 11-053 Ef : 7f ,1,,13) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 1 # $236.00 Alternative Energy System IPHOTOVRES Photovoltaic System Suppl. PC Fee: Q Reg. Q OT 0.0 hrs $0.00 PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Fee.0 Reg. Q OT 0,0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 Construction Tax: Administrative Fee: 0 E) Work Without Permit? O Yes No $0.00 Advanced Planning_Fee: $0.00 Select a Non -Residential Building or Structure 0 Trcn,el Documentation Fees: Strong Motion Fee: 1BSEISMICR $3.77 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $2.00 SUBTOTALS: $5.77 $236.001_TOTAL FEE: $241.77 Revised: 02/14/2015 WATER -CONSERVING PLUMBING FIXTURES FILE OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION n�– CUPERTINO 1030D TORRE AVENUE CUPERTINO,CA950143255 (408) 777-3228 • FAX (408) 777-3333 buildino(a cupertino.oro Owner Name i�ry ''.> L S I n n 1 Permit No. Address L� �1 Z A, /,2 CANNOT BE PL�,1LFD A\ -D COMPLETED LN TIL THIS CERTIFICATE Please refer to the attached California Civil Code Sections 1101.1-1101.8 which are part of this Certification form. . 1. Is your real property a registered historical site? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Owner' Signature:Y�GY— CyNo Go to Question 2. Sign below and skip the rest of the form. Date: SN, !� 2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its plumbing, installation of water -conserving plumbing fixtures is not technically feasible? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. ❑ The licensed plumber's certification has been provided to the Building Division. Sign below and skip the rest of the form Owner' Signature: Date: * No Go to Question 3. 3. Is water service permanently disconnected for your building? ❑ Yes Civil Code Sections 1 i 01.1 through 1101.8 do not apply. Sign below and skip the rest of the form. Owner' Signature. c' hr r^ Date:/�/� Is �i No Go to Question 4. �d fiy�p—J.([` (( I 4. Is your real property built and available for use or occupancy on or before January 1, 1994? ❑ No My real property is built and available for use or occupancy after January 1, 1994. Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of/!the conn. Owner' Signature: Date: S is �J 4a Yes My real property is built an available for use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101.8 apply. Refer to the attached. El My property is a single-family residential real property. See Civil Code Section 1101.4. On and after January 1, 2014, building alterations or improvements shall require all non-compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non-compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements). ❑ My property is a multifamily residential real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water - conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). ❑ My property is a commercial real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. SB407 2014.doc revised 03118/14 On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). I/We, the owner(s) of this property, certify under penalty of perjury that non-compliant plumbing fixtures have been replaced with water -conserving plumbing fixtures in accordance with Civil Code Sections 1101.1 through 1101.8, the current California Plumbing Code and California Green Building Standards Code, and manufacturer's installation requirements, and that the water -conserving plumbing fixtures co 1 with the re uirements as indicated in the table below. Owner's (or Owner Agent's) Signature: Date: Upon completing and signing this Certificate, please return it to the Building Division in order to final your permit. 1. If the existing plumbing fixture water usage/flow rate is equal to or lower than the figure shown, it is not required to be upgraded. SB4072014.doc revised 03/18/14 Non -Compliant P _. _ Water -Conserving Plumbing Fixture. Plumbing Fixture (Fixture Complying with Current Code Applicable to New Construction) Maximum Water Usage/Flow Rate Fixture Type Water Usage 2013 CPC Ch. 4 2013 CPC Ch. 4 2013 CPC Ch. 4 /Flow Rate 2013 CALGreen Div. 4.3 2013 CALGreen Div. 4.3 2013 CALGreen Div. 5.3 Single -Family Multi -Family Commercial Residential Residential Water Closets Exceed 1.6 Single flush toilets: 1.28 gallons/flush (Toilets) Gallons/flush Dual flush toilets: 1.28 gallons/flush effective flush volume (the composite, average flush volume of two reduced flushes and one full flush Urinals Exceed 1.0 0.5 gallons/flush Gallons/flush Showerheads Exceed 2.5 2.0 gallons per minute @ 80 psi. Also certified to the performance criteria of gallons per minute U.S. EPA WaterSense Specification for Showerheads (A hand-held shower is considered a showerhead.) For multiple showerheads serving one shower, the combined flow rate of all showerheads and/or other shower outlets controlled by a single valve shall not exceed 2.0 gallons per minute @ 80 psi, or the shower shall be designed to allow only one shower outlet to be in operation at a time. Faucets — Exceed 2.2 gallons Maximum 1.5 gallons per Within units: 0.5 gallons per minute @ 60 Lavatory per minute minute @ 60 psi; minimum Maximum 1.5 gallons psi Faucets 0.8 gallons per minute @ per minute @ 60 psi; 20 psi minimum 0.8 gallons per minute @ 20 psi In common and public use areas: 0.5 gallons per minute @ 60 psi 1.8 gallons per minute 60 psi Faucets — Exceed 2.2 gallons 1.8 gallons per minute @ 1.8 gallons per minute 1.8 gallons per minute @ 60 Kitchen per minute 60 psi @ 60 psi psi Faucets May temporarily increase May temporarily up to 2.2 gallons per increase up to 2.2 minute @ 60 psi, and must gallons per minute @ default to maximum 60 psi, and must 1.8 gallons per minute @ default to maximum 60 psi 1.8 gallons per minute Where faucets meeting @ 60 psi .,, ._.. _ .. the above are unavailable, Where faucets meeting aerators or other means the above are may be used to achieve unavailable, aerators or reduction. other means may be used to achieve reduction. 1. If the existing plumbing fixture water usage/flow rate is equal to or lower than the figure shown, it is not required to be upgraded. SB4072014.doc revised 03/18/14 Address /0 3 0 Z 0''(1 SMOKE / CARBON MONOXIDE ALARMS FILE OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • buildingaftupertino.org Permit No. /�oDOy PERMIT CANNOT BE FII\TALED AND COMPLETED UNTIL THIS CERTIFICATE ' HAS BEEN SIGNED AND RETURNED TO THE BUILDING DIVISION PURPOSE This affidavit is a self -certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R314,2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single-family and multi -family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds $1000.00, CRC Section R314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations: AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of the bedroom(s) X X On every level of a dwelling unit including basements X X Within each sleeping room X Carbon Monoxide alarms are not required in dwellings which do not contain fuel -burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. Power Supply: In dwelling units with no commercial power supply, alarm(s) may be solely battery operated. In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl space. Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2. An electrical permit is required for alarms which must be connected to the building wiring. As owner of the above -referenced property, I hereby certify that the alarm(s) referenced above has/have been installed in accordance with the manufacturer's instructions and in compliance with the California Building and California Residential Codes. The alarms have been tested and are operational, as of the date signed below. I have read and agree to comply with the terms and conditions of this statement Owner (or Owner gents) Name: Ct fro I ,(- 7 Si nature ............. . .......................................... Date: ..c . Contractor Name: lay✓ .,1.(�lC .,x.6. s Si nature..................................................Lic.# ........ 3............. Date: /I Smoke and CO forni.doc revised 03/18/14 solar SolarEdge Single Phas( For North America SE300OA-US 1 SE38OOA-US / SE5O00A. SE760OA-US / SE1000OA-US / SE114OO ���erier 25 i lea wacca�C1 ; r 4) — V The best choice for SolarEdge enabled systems = Integrated arc fault protection (Type 1) for NEC 2011 690.11 co li ATE 1 Superior efficiency (98%) ' ` 1 LLLL........ Small, lightweight and easy to install on provided bracket Built-in module -level monitoring m Internet connection through Ethernet or Wireless PLANNING DEPT Outdoor and indoor installation = Fixed voltage inverter, DC/AC conversion only CUPERTINO = Pre -assembled AC/DC Safety Switch for faster installation Optional built-in revenue grade meter 'F USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - AUSTRALIA- THE NETHERLANDS - ISRAEL www.solaredge.us n. solar' Single Phase Inverters for North America • • Sc3000A-US % SE3300A-US i SE5000A-US / SE6000A-US! SE760OA-US / SEt0000A-US / SE11400A-US SE3000A-US SE3800A-US SE5000A-US SE6000A-US SE760OA-US SE1000OA-US SE11400ti-US OUTPUT i 9980 @ 208V ;- -�- -- Nominal AC Power Output 3300 3840 5000 ( 6000 7680 101.000 @240V 11520 VA 5400 @ 208V ! 10800 208V I Max. AC Power Output 3650 4150 5450@240V.i 1 6000 8350 .............. ..... ... . 10950@240V I... ..............(.... 12000 VA AC Output Voltage Min. -Nom. -Max.* 1; I 183 - 208 - 229 Vac ......................... ... I........-.. ......!...... .......... .......... AC Output Voltage Min: Nom. -Max.* j I 211- 240 - 264 Vac I ...... .... ...... AC Frequency Min. -Nom. -Max.' j � 59.3 - 60 - 60.5 (wi1.th HI country setting 57 - 60 - 60.5) ..... . Hz 1 Max Continuous Output Current 14 16 24 @ 208V ' 25 32 48 @ 208V 48 A 21 @ 240V 42 @ 240V GFDI............ .�. . ............1.. .. .............,... ..................... ...........I........... ....... I — . _... Utility Monitoring, Islanding E I Protection, Country Configurable Yes Thresholds I -- ----.---- ------ INPUT - -- ----- - -------4- DPower** Recommended Max. C --,-4100 i --4800 - --- --- --i- - - (STC) .......... ..... .. . . ..... ....................... ...............I................. 6250 7500 9600 I 12400 14400 W Transformer -less, Ungrounded j Yes Max. Input Voltage . 500 ............................... ........ .....-....... Vdc .............................................. Nom. DC Input Voltage j ........ ................................... ..... 325 @ 208V / 350 @ 240V .. .... .....- -- - .....................-...... _.... ... .. Vdc j 116.5@01208V 33 @ 208V Max. Input Current"' .......... it ...... ... 13 15.5 @ 240V. - I 18 j 23.5 ....... .305 @ 240V 35 Adc Max. Input Short Circuit Current 30 ! 45 Adc Reverse -Polarity Protection ..... Yes ......................... ....... .................. .......... ... . ..........I..... .. ............ Ground -Fault Isolation Detection ... ....... - ..........i........... .. 600ku Sensitivity ..........I.................. ........... ....................................I Maximum Inverter Efficiency 97.7 ! 98.2 �. 98.3 98.3 I........ 98 98 98 % .......................................................................... ..... 197.5 @ 208V .. ........... 1 ....I............................. 97 08V CEC Weighted Efficiency ...... ..... 97.5 98 i 1.. 98C�240V .' 97.5 97.5 I.................._....-.......(..97.5@240V..;..................I.......... 97.5 % Nighttime Power Consumption _ -- - < 2.5 <4 W ADDITIONAL FEATURES Supported Communication Interfaces .........................................................P....... ..............I.......................... RS485, RS232, Ethernet, ZigBee (optional) ,............... ............. .... I...... Built-in Revenue Grade Meter I Optional a truvvnts� a.vmrursna.c Safety -r- . , .. UL1741, UL16998, UL1998 , CSA 22.2 I Grid Connection Standards i IEEE1S47 . ......_ ...... ......... ...i..................................... ............ ... _...,.......... ................................ ..... .... ......... ...... Emissionsp_ _ -- _ FCC art1S class B - Y- l INSTALLATION SPECIFICATIONS _ AC output conduit size / AWG range 1; 3/4" minimum/ 24-6 AWG { 3/4" minimum/ 8-3 AWG DC input conduit size / q of strings / I 3/4" minimum / 1-2 strings / 24-6 AWG -3/4" minimum / 1-2 strings / 14-6 AWG AWGrange ........... .............. ...�................ -... ... ....... .....,...................................... ............... I.......... ........... Dimensions with AC/DC Safety 30.5 x 125 x 7 / 30.5 x 12.5 x 7.5 / in/ Switch (HxWxD) ! 775 x 315 x 172 775 x 315 x 191 x 10.5 / 775 x mm . ... ....................... ... Weight with AC/DC Safety Switch S1.2 / 23.2 ! 54.7 / 24.7 12 5 88 A / 40.1 ' 315 ' Ib / k$ x z ................... _. . ..... ..... .. .... ...... .... Cooling Natural Convection Fans (user replaceable) ........... ... ........ .. _......................... ................. ...... ................. ........... Noise < 25 I < 50 I dBA . ... _ ..................................I... . . ...................... _.........................---................................I........... Min: Max. Operating Tempera ture -13 to +140/ -25 to +60 (CAN version,*** -40 to +60) I 'F /'C Range Protection Ratin gNEMA 3R . ............ . - ............................ ....... ..... ................ ............... i........... • For other regional settings please contact SolarEdge support. •• limited to 125% for locations where the vearH average high temperature is above 77'F/25 C and to 135% for locations where it is below 77'F/25'C. For detailed information, refer to httoJ/www.solaredee.us/files/odfs/inverter do oversiymt euide.odf rA 0 • 21.5% efficiency Ideal for roofs where space is at a premium or where future expansion might be needed. Maximum performance Designed to deliver the most energy in demanding real world conditions, in partial shade and hot rooftop temperatures. '• 2.3 • Premium aesthetics SunPower®Signature' Black X -Series panels blend harmoniously into your roof. The most elegant choice for your home. . moxeon® Solar Cells: Fundamentally better. Engineered for performance, designed for durability Engineered for peace of mind Designed to deliver consistent,trouble-free energy over a very long lifetime.a,s Designed for durability The SunPower Maxeon Solar Cell is the only cell built on a solid copper foundation. Virtually impervious to the corrosion and cracking that degrade Conventional Panels.a,s Same excellent durability as E. -Series panels. # 1 Ranked in Fraunhofer durability test:'° 100% power maintained in Atlas 25+ comprehensive PVDI Durability test." UNMATCHED PERFORMANCE, RELIABILITY & AESTHETICS SIGNATURETM BLACK ; X21 345 PANEL X21 - 335 PANEL HIGHEST EFFICIENCY°� rOFt LODE LnMp��ANMI✓ Generate more energy per square foot X -Series residential panels convert more sunlight to electricity producing 44 more power per panel,' and 75% more energy per square foot over 25 years -3.4 HIGHEST ENERGY PRODUCTION 7 Produce more energy per rated watt High year one performance delivers 8-10% more energy per rated waft .3 This advantage increases over time, producing 21 % more energy over the first 25 years to meet your needs.' a 120%.21% ------------- ------- I Power at High Temps More Energy c 110% Per Rated. Watt 5 100% Degradation Q • - - - High Average Watts 90% 4% a Better. low --Light and "`----- rn 80% Spectral Response m LU ------- Co-ive-itio-Ewl 0 60% N 50% 0 5 10 15 20 25 Years --- --- - -- -- - --- j Maintains High 36% more, year 25 �5,�-1ERGY pf�� PHOTON; 'o-'2F_160�, A—d.d to SwPow.r ES.rie,. ma....qY., sunpowercorp.com 8,� ------- I Power at High Temps m--------- No Lightlnduced 0 6% --------- .."--- Degradation Q High Average Watts 4% --------- Better. low --Light and "`----- `c Spectral Response 2% ------- -------- a Anti-Reflective Anti -Reflective Glass 36% more, year 25 �5,�-1ERGY pf�� PHOTON; 'o-'2F_160�, A—d.d to SwPow.r ES.rie,. ma....qY., sunpowercorp.com 100% 95% 90% 85% 80% 75% 6WER AND PRODUCT WARRANTY SUNPOWER OFFERS THE BEST COMBINE"j POWER WARRANTY 7 5 10 15 20 25 Years More guaranteed power: 95% for first 5 years,-0.4%/yr, to year 25. a ELECTRICAL DATA Temperature — 40'F to +I 85'F (— 40aC to +85'C) X21-335-BL.K X21-345 Nominal Power12 (Pnom) 335 W 345 W Power Tolerance +5/-0% +5/-0% Avg. Panel Efficiency11 21.1% 21..5% Rated Voltage (Vmpp) 57.3 V 57.3 V Rated Current (Impp) 5.85 A 6.02 A ltage (Voc) 67.9 V 68.2 V EShort-Circuitrrent (Isc) 6 .23 A 6.39 Am Voltage 600 V UL; 1000 V JEC s Fuse 20A Power Temp Coef. (Pmpp) —0.30% / aC Voltage Temp Coef. (Voc) —167.4 mV / aC Current Temp Coef. (Isc) 3.5 mA / IC REFERENCES: 1 Al comparisons are SPR -X21-345 vs. a representative conventional panel: 240W, approx 1.6 m2, 15% efficiency. 2 PVEvolution Labs "SunPower Shading Study," Feb 2013. 3 Typically 8-10% more energy per watt; BEW/DNV Engineering "SunPower Yield Report" Jan 2013, with CFV Solar Test Lab Report #12063, Jan 2013 temp. coef. calculation. 4 SunPower 0.25%/yr degradation vs. 1.0%/yr conv. panel. Campeau, Z. et al. "SunPbwer Modple Degradation Rate," SunPower white paper, Feb 2013; Jordan, Dirk "SunPower Test Report" NREL, Oct 2012. 5 "SdhPower Module 40 -Year Useful Life" "SunPower white paper, Feb 2013. Useful life is 99 out of 100 panels operating at more than 70% of rated power. 6 Nigher than E Series which is highest of all 2600 panels listed in Photon Intl, Feb 2012. 7 1 % more energy than E -Series panels, 8% more energy than the average of the top 10 panel companies tested in 2012 (151 panels, 102 companies), Photon fnPI, Mar 2013. 8 Compared with the top 15 manufacturers. SunPower Warranty Review, Feb 2013. 9 Some exclusions apply. See warranty for details. 10 X -Series same as E -Series, 5 of top 8 panel manufacturers were tested by Fraunhofer ISE, "PV Module Durability Initiative Public Report," Feb 2013. 11 Compared with the non-chess-tesfed control panel. X -Series some as E -Series, tested in ANos 25+ Durability test report, Feb 2013. 12 Standard Test Conditions (1000 W/m2 irradiance, AM 1.5, 25" C). 13 Based on average of measured power values during production. PRODUCT WARRANTY 5 10 15 20 25 Years Combined Power and Product Defect 25 year coverage that includes panel replacement costs.' OPERATING CONDITION AND MECHANICAL DATA Temperature — 40'F to +I 85'F (— 40aC to +85'C) Max load Wind: 50 psf, 2400 Pa, 245 kg/m2 front & back Snow: 112 psf, 5400 Pa, 550kg/m2 front Impact i resistance 1 inch (25 mm) diameter hail at 52 mph (23 m/s) I Appearance Class A+ Solar Cells 96-Monocrystalline Maxeon Gen III Cells Tempered Glass High Transmission Tempered Anti -Reflective .function Box IP -65 Rated Connectors MC4 Compatible 1 Frame Class 1 black anodized, highest AAMA Rating Weight 41 lbs (18.6 kg) l 1046mm [41.2in] 46mm [1.81 in] 1559mm [61.4in] See htta://www.sunpowermm.com/facts for more reference information. For further details, see extended dotasheet: www.sunpowercoro.com/daiushecits Read safety and installation instructions before using this product. O April 2013 SunPower Coryomlion. AN rights miwmd. SUNPOWER, the SUNPOWER 1090,. MAXEON, MORE ENERGY. FOR UFE., and SIGNATURE oro trademarks or mgW@md trademarks of SunPa mr Corporation. Specifications induded in this dabsh"t aro subject to change without natia. - su n powe rco rp. com D --.t # 504828 Ra. A ATR EN TESTS AND CERTIFICATIONS j Standardtests UL 1703, IEC61215,IEC 61730 Quality tests ISO 9001:2008, ISO 1.4001:2004 j EHS.Compliance ROHS, OHSAS 18001:2007, lead-free j Ammonia test IEC 62716 !I Salt Spray test IEC 61701 (passed maximum severity) PID test Potentiol4nduced Degradation free: 1000V 10 Available listings - CEC,-UL, TUV, MCS 1046mm [41.2in] 46mm [1.81 in] 1559mm [61.4in] See htta://www.sunpowermm.com/facts for more reference information. For further details, see extended dotasheet: www.sunpowercoro.com/daiushecits Read safety and installation instructions before using this product. O April 2013 SunPower Coryomlion. AN rights miwmd. SUNPOWER, the SUNPOWER 1090,. MAXEON, MORE ENERGY. FOR UFE., and SIGNATURE oro trademarks or mgW@md trademarks of SunPa mr Corporation. Specifications induded in this dabsh"t aro subject to change without natia. - su n powe rco rp. com D --.t # 504828 Ra. A ATR EN 25800 Commercentre Drive Lake Forest, CA 92630 USA Telephone: 949.448.4100 Facsimile: 949.448.4111 www.intertek.com In the basis of the tests undertaken, the sample(s) of the below product have been found to comply with the requirements of the referenced specifications at the time the tests were carried out. t-1 IPEKI INU Name & Address: Product Description: Ratings & Principle Characteristics: Models: Brand Name: Relevant Standards: Verification Issuing Office: Date of Tests: Test Report Numberl Professional Solar Products, Inc. 1551 S. Rose Avenue Oxnard, CA 93033 Photovoltaic Racking System, Roof System Fire Class Resistance Rating: -Class A for Steep Slope Al Rooffrac when u APR 07215 Cai�F COMPLIANCE REV;EV aev�ewe� tsy � 1 and Type 2, Listed Photovoltaic Modules. NroSolar UL Subject 2703 (Section 15.2 and 15.3) Outline of Investigation for Rack Mounting Systems and Clamping Devices for Flat -Plate Photovoltaic Modules and Panels, Issue Number: 2, Nov 13, 2012 Referencing UL1703 (Section 31.2) Standard for Safety for Flat -Plate Photovoltaic Modules and Panels, May 20, 2014 Intertek Testing Services NA, Inc. 25800 Commercentre Dr. Lake Forest, CA 92630 12/12/2014 through 12/30/2014 100779407LAX-003 This verification is part of the full test report(s) and should be read in conjunction with them. This report does not automatically imply product certification. Completed by: Michael Hoffnagle Title: PV Engineer Signature: Date: 02/23/2015 Reviewed by: Amar Ka cel Title: Reviewer Signature: Date: 02/24/2015 This Verification is for the exclusive use of lntertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its - marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever beer under an Intertek certification program. GFT -OP -11a (24 -MAR -2014) CERTIFICATE OF COMPLIANCE Certificate Number 20150223-E246423 Report Reference E246423-20040917 Issue Date 2015 -FEBRUARY -23 Issued to: SUNPOWER CORP 77 RIO ROBLES SAN JOSE CA 95134 This is to certify that PHOTOVOLTAIC MODULES AND PANELS representative samples of (See addendum for additional information.) Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: UL 1703, 3rd Edition, revised May 20, 2014, "Standard for Safety for Flat -Plate Photovoltaic Modules and Panels." Additional Information: See the UL Online Certifications Directory at www.ul.com/database for additional information Only those products bearing the UL Listing Mark for the US and Canada should be considered as being covered by UL's Listing and Follow -Up Service meeting the appropriate requirements for US and Canada. The UL Listing Mark for the US and Canada generally includes: the UL in a circle symbol with "C" and "US" identifiers:(61)°S the word "LISTED",- a control number (may be alphanumeric) assigned by UL.- and L;and the product category name (product identifier) as indicated in the appropriate UL Directory. Look for the UL Listing Mark on the product. C uV:iERTINO ;q°jv`:lulnc Department "! ��'� 7 20►� cars• u,r,hcE �,EVIE�`�r U FOR CODS avieu4���1 3y. William R. Camey, Director, North American Certification Programs ■ UL LLC L Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at w—ul.con✓comact- Page 1 of 2 CERTIFICATE OF COMPLIANCE Certificate Number 20150223-E246423 Report Reference E246423-20040917 Issue Date 2015 -FEBRUARY -23 This is to certify that representative samples of the product as specified on this certificate were tested according to the current UL requirements. Photovoltaic Modules: Models XXX -440 to -410, -408, -405, -402, -400, -398, -395, -392, -390, -388 —385, -382, -380, -375, - 345 to -293, -290, -285, -280, -250 to -225, followed by E or NE, may be followed by -BLK or —WHT, followed by -D, -I, or—U, where XXX represents SPR or SPV. Models XXX-EYY-### where XXX represents SPR or SPV, YY represents 18, 19, 20 or 21 and ### is any number from 440 to 375 or 345 to 285 or 250 to 225 and may be followed by —COM and/or -BLK Models XXX -450 to -435, XXX -345 to -311, XXX -262 to -233 followed by J, NJ, NX or X, may be followed by -BLK or -WHT, followed by -D, -1, -or -U, where XXX represents SPR or SPV. Models XXX-XYY-### where XXX represents SPR or SPV, YY represents 18, 19, 20 or 21 and ### is any number from 486 to 435 or 365 to 310 or 274 to 233 and may be followed by —COM and/or —BLK Flat -Plate Photovoltaic Modules with construction compliant to Module Fire Performance Type 2. CVpr ,partnont ,;1V0d'1n9 Rev1e\,N 13y William R. Carney, Director, North American Certification Programs ■ UL LLC L Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at vrvw.ul.contfconmcul Page 2 of 2 A CITY OF CUPERTINO 10300 Torre Avenue Telephone 777-3228 INSPECTION NOTICE BUILDING DIVISION JOB DATE ADDRESS TIME DAILY REPORT:a CORRECTION NOTICE -J" VIOLATION C3 TYPE INSR: BLDWEI ELEC. L) PLBG.0 MECH.:1 Ll STOP WORK Ll REINSPECTION FEE I WEATHER---INSP. CARD TO REMAIN ON .1.013 -SITE 3 CITY OF CUPERTINO BUILDING PERMIT INSPECTION CARD BUILDING ADDRESS: 10382 MIRA VISTA RD coNTPuCTOR: POLO SOLAR PERMIT NO: 15040047 OWNER'S NAME: STANEK MICHAEL W AND CAROL 3345 KELLER ST DATE ISSUED: 04/07/2015 OWNER'S PHONE. 4082652311 SANTA CLARA, CA 95054 PHONE NO: (408) 970-0680 F F I— �— BUILDING PERMIT INFO: BLDG ELECT PLUMB MECH RESIDENTIAL COMMERCIAL JOB DESCRIPTION: INSTALL (14) PANEL PV SYSTEM ON SFDWL 4.8 KW \ - FOUNDATION/PIERS/H D S UFER GROUNDI— TBACK-CERT GARAGE SLABS/PREGUNITE UNDERGROUND/SLAB UNDERGROUND PLUMBING UNDERGROUND ELECTRICAL UNDERFLOOR PLUMBING UNDERFLOOR MECHANICAL WILDLAND URBAN INTERFACE FIRE AREA ER# TO ARRANGE INSPECTION Call 777-3228 between 7:30 am and 3:30 pm Monday through Friday, at least 24 hours before required inspection. Job address and Permit Numbers are needed when requesting an inspection. CUPERTINO SANITARY DISTRICT Closed circuit video inspection of property line cleanout, point of connection and street lateral required prior to passing FINAL CITY PLUMBING INSPECTION. Call the District (408-253-7071) for an appointment. NO BUILDING FINALS INSPECTIONS UNTIL ALL REQUIRED BUSINESS LICENSES ARE OBTAINED PERMIT EXPIRES IF WORK IS NOT STARTED WITHIN 180 DAYS OF PERMIT ISSUANCE OR 180 DAYS FROM LAST CALLED INSPECTION. IMPORTANT When a permit has expired, a charge totaling one-half the fees to obtain a new permit must be paid in order to reactivate the permit. If a permit has been expired for more than one year, a charge totaling the full fees to obtain a new permit must be paid to reactivate the permit NOTES: SPECIAL INSPECTIONS Inspector: Date: ROOF INSPECTIONS PRE -INSPECTION: Inspector: Date: TEAR -OFF: Inspector: Date: PLYWOOD: inspector: Date: BATTENS: Inspector: Date: IN PROGRESS: Inspector: Date: FINAL: Inspector: Date: NOTE: OSHA APPROVED ACCESS TO ROOF SHALL BE PROVIDED FOR INSPECTION. OCCUPANCY OF BUILDING NOT PERMITTED UNTIL BUILDING FINAL IS SIGNED BY INSPECTOR UNDERFLOOR ELECTRICAL UNDERFLOOR FRAMING VENTS UNDERFLOOR INSULATION PYAEF ROOF SHEATHING ROUGH PLUMBING TUBS & SHOWER PAN ROUGH MECHANICAL ROUGH ELECTRICAL/POOL BOND FRAMING/STAIRS/E. EGRESS WSULATION/VENTILATION Clvaw ' '� ;. IIA_ � EXTERIOR SHEAR/NOLD DOWN INTERIOR SHEAR/HOLD DOWN SHEETROCK/SHEETROCK SHEAR EXTERIOR LATH/W-SCREED INTERIOR LATH NO TAPE A51BR .HEI i1i SLGNED . ., SCRATCH COAT SEWERIWATER ABOVE CE1L �Tv--B�AR/MECH/ELECT ELECTRIC METER RELEASE GAS TEST/METER RELEASE GRADE -PUBLIC WORKS FIRE - CALL (408) 3784010 PLANNING (408) 777-3308 SANITARY (408) 253-7071 ELECTTRICAL J MECHANICAL PLUMBING HANDICAP ENERGY BUILDING ,S•1l•1 CERTIFICATE OF OCCUPANCY i 2 Strings w/7 Ea. SunPower #10 XLP USE -2 SPR -x21-345 3/4" EMT - W/ #10 Bare 4 ea. #10 THWN-2 Copper Bond w/ #10 Ground 7 ea. J -Box 7 ea. Voltage and Current: 2 Strings w/ 7 ea. in Parallel Max. Power 4830 Watts DC Max. Power Voltage DC 477.4 Voc (x temp coefficient) 596.8 Voc Max. Power Current 18 Isc (x 1.25 irradiance) 22 Isc Sunnower SPR -x21-345 Peak Power Watts : 345 W Max. Power Voltage : 57.3 Vmp Max. Power Current 6.02 Imp Open Circuit Voltage : 68.2 Voc Short Circuit Current : 6.39 Isc nek, Mike & Carol 0382 Mira Vista Rd. upertino, CA 95014 3/4" EMT - 3 ea.#8 THWN w/ Meter #8 Ground Solar Edge SE -5000A -US [200 Amp Main w/ (240v) Inverter with Disconnect CUPERTINO �iuirdinq DeoariTrPn? APR 0 7 2015 FOH CODk COMPLIANCE <PviPwed F3yi � - Grounding and Bonding 30 Amp Load Side Solar Breaker All Modules, Rail, Boxes, and Conduit will have a Continued Bond with #10 Bare Copper and DB Copper Lugs . All bonding and Grounding will Comply with Article 690.41-690.49 Inverters: Solar Edge SE500OA-US Input: DC Max. Power 6750 Watts Max. DC Voltage 500 Volts Max. Current DC 45 Amps Output: AC Max. Power 5000 Watts Max. Current AC 21 Amps Weight 54.7 Lbs Poco Solar Inc. 3345 Keller Street Santa Clara, Ca. 95054 265-2311 1 Lic. # 879366 All Warning Labels Shall Conform to UL 969, White Labels, Red Lettering Installation Shall be in Full Compliance of the Following Codes: a. 2013 California Building Code (2012 IBC) b. 2013 California Residential Code (2012 IRC) c. 2013 California Electrical Code (2012 NEC) d. 2013 California Fire Code All electrical equipment shall meet the 2012 CEC 110.26 required working clearances and accessibility Meter/Main w/ Warning Labels All PV Equipm4 Marked with We; Resistant Warnin Guidance Lane.. Inverter, AC/DC Disconnects w/ Warning labels Conduit Routed on Roof with Signage stating: nek, Mike & Carol 0382 Mira Vista Rd. Cupertino, CA 95014 408) 265-2311 U Clearance O Auess Pathway Attachment Points Driveway 0 Access ❑E W Z fn 14 Flush Roof Mounted PV Modules Roof: 1 Stories Material: Single Layer Comp. Planes: 270 Pitch: 5/12 Rafters: 2" x 6" Spacing: 16" O.C. Fast Jacks Lagged into Rafters with a Minimum of 2 1/2" Embedment SunPowerSPR-345NE-WHT-D 17.1 Sq. Ft. 41 Lbs 2.4 Lbs per Sq. Ft. 3.03 Lbs per Sq. Ft. W/ Hardware and Rails 725.4 Max. Lbs Attachment Points: 32 Lbs Per Attachment: 22.7 Existing Pool Solar Heating Panels 74C;;(.2 Cj?e— ��G C Rail 6'4gALTi-rJ n-�Jnli C.�17h `�'uiERTINO wilding Department APR 0 7 2015 REVIEwc- 0 F :'t CODE COMPLIANCE iZeviewed By Vista Road 3345 Keller Street Santa Clara, Ca. 95054 yP _ a Lic. # 879366 Egg d l So �OD.� 0 FFS c ,