15040047CITY OF CUPERTINO BUILDING PERMIT
BUILDING ADDRESS: 10382 MIRA VISTA RD
CONTRACTOR: POCO SOLAR
PERMIT NO: 15040047
OWNER'S NAME: STANEK MICHAEL W AND CAROL
3345 KELLER ST
DATE ISSUED: 04/07/2015
OWNER'S PHONE: 4082652311
SANTA CLARA, CA 95054
PHONE NO: (408) 970-0680
❑ LICENSED CONTRACTOR'S DECLARATION
JOB DESCRIPTION: RESIDENTIAL COMMERCIAL ❑
INSTALL (14) PANEL PV SYSTEM ON SFDWL 4.8 KW
License Class ((", (y�_Z Lic. # � C't ���1�
o
Contractor ate
I hereb rim that I am licensed under the provisions of Chapter 9
(commencing with Section 7000) of Division 3 of the Business & Professions
Code and that my license is in full force and effect.
I hereby affirm under penalty of perjury one of the following two declarations:
I have and will maintain a certificate of consent to self -insure for Worker's
Compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
Sq. Ft Floor Area:
%'aluation: $29100
have and will maintain Worker's Compensation Insurance, as provided for by
APN Number: 35702018.00
Oeeupa 11c! 1 ` Pe:
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued.
APPLICANT CERTIFICATION
I certify that I have read this application and state that the above information is
PERMIT EXPIRES IF WORK IS NOT STARTED
correct. I agree to comply with all city and county ordinances and state laws relating
WITHIN 180 DAYRMIT ISSUANCE OR
to building construction, and hereby authorize representatives of this city to enter
upon the above mentioned property for inspection purposes. (We) agree to save
indemnify and keep harmless the City of Cupertino against liabilities, judgments,
rTCALLED
180 DAYS FR INSPECTION.
45,
costs, and expenses which may accrue against said City in consequence of the
Issued by: Date:
granting of this permit. Additionally, the applicant understands and will comply
with all non -point source regulations per the Cupertino Municipal Code, Section
9.18.
( ^� r
(4/7A.5-
RE -ROOFS -
Signature Date l .
Signature
All roofs shall be inspected prior to any roofing material being installed. If a roof is
installed without first obtaining an inspection, I agree to remove all new materials for
inspection.
❑ OWNER -BUILDER DECLARATION
Signature of Applicant: Date:
I hereby affirm that I am exempt from the Contractor's License Law for one of
the following two reasons:
ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER
I, as owner of the property, or my employees with wages as their sole compensation,
will do the work, and the structure is not intended or offered for sale (Sec.7044,
Business & Professions Code)
I, as owner of the property, am exclusively contracting with licensed contractors to
HAZARDOUS MATERIALS DISCLOSURE
construct the project (Sec.7044, Business & Professions Code).
I have read the hazardous materials requirements under Chapter 6.95 of the
California Health & Safety Code, Sections 25505, 25533, and 25534. I will
I hereby affirm under penalty of perjury one of the following three
maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the
declarations:
Health & Safety Code, Section 25532(a) should I store or handle hazardous
I have and will maintain a Certificate of Consent to self -insure for Worker's
material. Additionally, should I use equipment or devices which emit hazardous
Compensation, as provided for by Section 3700 of the Labor Code, for the
air contaminants as defined by the Bay Area Air Quality Management District I
performance of the work for which this permit is issued.
will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and
'
I have and will maintain Worker's Compensation Insurance, as provided for by
the Health & Safety Code, Scs 25505, 255 3, a 25534. C�
Section 3700 of the Labor Code, for the performance of the work for which this
Owner or authorized agen Date: l /•
permit is issued.
I certify that in the performance of the work for which this permit is issued, I shall
not employ any person in any manner so as to become subject to the Worker's
CONSTRUCTION LENDING AGENCY
Compensation laws of California. If, after making this certificate of exemption, I
become subject to the Worker's Compensation provisions of the Labor Code, I must
I hereby affirm that there is a construction lending agency for the performance of
forthwith comply with such provisions or this permit shall be deemed revoked.
work's for which this permit is issued (Sec. 3097, Civ C.)
Lender's Name
APPLICANT CERTIFICATION
Lender's Address
I certify that I have read this application and state that the above information is
correct. I agree to comply with all city and county ordinances and state laws relating
to building construction, and hereby authorize representatives of this city to enter
upon the above mentioned property for inspection purposes. (We) agree to save
ARCHITECT'S DECLARATION
indemnify and keep harmless the City of Cupertino against liabilities, judgments,
costs, and expenses which may accrue against said City in consequence of the
I understand my plans shall be used as public records.
granting of this permit. Additionally, the applicant understands and will comply
with all non -point source regulations per the Cupertino Municipal Code, Section
Licensed Professional
9.18.
Signature Date
ALTERNATIVE ENERGY PERMIT APPLICATION
a'A
Ote
COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION
10300 TORRE AVENUE • CUPERTINO, CA 95014-3255
(408) 777-3228 • FAX (408) 777-3333 • building(a cupertino.org
AE
Q S j
PROJECT ADDRESS (D Z M \J1
APN # S_�
3 (, 'v (o, 1 t, dA
V✓
O14ERNAME
S
PH E-MAILlJ
N
X10 2(5 ca 00gV% I. r
a►�Q
e S ,Ma'
STREET ADDRESSO
(� ` r i
CIS V STAQTE(ZjPI �O �� 9 � O I L FAX
`
///A111\
PHOA 3 1 . i d - 9 Z3 z
CONTACT NAME I, _I evr 1
v33
E-MAIL i� O 01 Q r CoV►j
STREET ADDRESS
CITY, $ A Y� �ZO\ C l Cvex CA 9 So qVq'O�N-
OS t
❑ OWNER ❑ OWNER -BUILDER ❑ OWNER AGENT ❑ CONTRACTOR % CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT
LICENSE NUMBER 81 Q � ( / LICENSE TYPE( � /
CONTRJJTORCN1''AME�� �� i
BUS. LIC #
Q% 1• NC
rQr_COMPANY
NAMECr C 1
E-MAIL I G1� ( UC
A(,CO
F � OS
STREET ADDRESS
STATE, ZIP
C•9 gSoS�
PHONE
%1c8 97 -0(
ARCHITECT/ENGrNEER NAME
LICENSE NUMBER
BUS. LIC #
Sa C. Co C_ loy
COMPANY NAME
E-MAIL
FAX
STREET ADDRESS
CITY, STATE, ZIP
PHONE
USE OF XI SFD or Duplex ❑ Multi -Family
PROJECT IN WILDLAND
PROJECT IN
STRUCTURE: ❑ Commercial
URBAN INTERFACE AREA ❑ Yes 11 NO
FLOOD ZONE ❑ Yes ❑ NO
SOLAR PANELS
❑ ELECTRIC VEHICLE CHARGING STATION
❑ SOLAR WATER HEATING
❑ OTHER:
FOR SOLAR PANELS: NUMBER OF PANELSAJNITS: ILI KILOWATTS (COMMERCIAL ONLY): LI ^ ,
N/
TOTAL VALUATION: n vO
G
DESCRIPTION OF WORK I J S `
h oo vrr►� 0i s'o��
� J I -1r\V2 f ter-
RECEIVED IM, -
By my signature below, I certify to each of the following: I am the property owner or authorized agent to act on the property owner's e ave read this
application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local
ordinances and state laws relating to building constio . I authorize representatives of Cupertino to enter the above -identified property for inspection purposes.
Signature of Applicant/Agent: Date: �1 S
SUPPLEMENTAL INFORMATION REQUIRED
6FFICEUSE01\LY
`2
: .
❑ OVER-THEUcbUNTER '
U
F" �
v
❑ .EXRR$SS � -
Ui�;.
U
t `
_
❑ LARGE
❑- M. O
PVApp_201 Ldoc revised 03/16/11
CITY OF CUPERTINO
UPF FCTTMATnR—RI111,11INf nIVIMON
lec. Plan Check
LteCII, Flee
01her 1'Iech. Insp irher Plumb Insp drier Llec. Insp. Li
,Meeh. Insp. free: r'htnib. Insp. Fee: hasp. hee:
NOTE: This estimate does not include fees due to other Departments (i.e. vianning, iwtrc works, rue, aantrary newer —strict, aur—
_ r__ L_ _J -. IL- -I-- »! ..*:.. ..:)oGlo .,d n o nnlu as oedmato. Cnatart tha AOnt for addn'l info.
FEE ITEMS (Fee Resolution 11-053 Ef : 7f ,1,,13)
ADDRESS: 10382 MIRA VISTA RD
DATE: 04/07/2015
REVIEWED BY: MENDEZ
APN:
BP#:
"VALUATION: 1$29,000
xPERMIT TYPE: Building Permit
PLAN CHECK TYPE: Alteration / Repair
PRIMARY SFD or Duplex
p
Suppl. PC Fee: Q Reg. Q OT
PENTAMATION SOLAR -RES
USE:
$0.00
PERMIT TYPE:
WORK
INSTALL 14 PANEL PV SYSTEM ON SFDWL 4.8 KW
SCOPE
Permit Fee:
lec. Plan Check
LteCII, Flee
01her 1'Iech. Insp irher Plumb Insp drier Llec. Insp. Li
,Meeh. Insp. free: r'htnib. Insp. Fee: hasp. hee:
NOTE: This estimate does not include fees due to other Departments (i.e. vianning, iwtrc works, rue, aantrary newer —strict, aur—
_ r__ L_ _J -. IL- -I-- »! ..*:.. ..:)oGlo .,d n o nnlu as oedmato. Cnatart tha AOnt for addn'l info.
FEE ITEMS (Fee Resolution 11-053 Ef : 7f ,1,,13)
FEE
QTY/FEE
MISC ITEMS
Plan Check Fee:
$0.00
1 #
$236.00
Alternative Energy System
IPHOTOVRES Photovoltaic System
Suppl. PC Fee: Q Reg. Q OT
0.0
hrs
$0.00
PME Plan Check:
$0.00
Permit Fee:
$0.00
Suppl. Insp. Fee.0 Reg. Q OT
0,0
hrs
$0.00
PME Unit Fee:
$0.00
PME Permit Fee:
$0.00
Construction Tax:
Administrative Fee:
0
E)
Work Without Permit? O Yes No
$0.00
Advanced Planning_Fee:
$0.00
Select a Non -Residential
Building or Structure
0
Trcn,el Documentation Fees:
Strong Motion Fee: 1BSEISMICR
$3.77
Select an Administrative Item
Bldg Stds Commission Fee: IBCBSC
$2.00
SUBTOTALS:
$5.77
$236.001_TOTAL
FEE:
$241.77
Revised: 02/14/2015
WATER -CONSERVING PLUMBING FIXTURES FILE
OWNER CERTIFICATE OF COMPLIANCE
COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION n�–
CUPERTINO 1030D TORRE AVENUE CUPERTINO,CA950143255
(408) 777-3228 • FAX (408) 777-3333 buildino(a cupertino.oro
Owner Name i�ry ''.> L S I n n 1 Permit No.
Address L� �1 Z A, /,2
CANNOT BE PL�,1LFD A\ -D COMPLETED LN TIL THIS CERTIFICATE
Please refer to the attached California Civil Code Sections 1101.1-1101.8 which are part of this Certification form. .
1. Is your real property a registered historical site?
❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply.
Owner' Signature:Y�GY—
CyNo Go to Question 2.
Sign below and skip the rest of the form.
Date: SN, !�
2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its
plumbing, installation of water -conserving plumbing fixtures is not technically feasible?
❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply.
❑ The licensed plumber's certification has been provided to the Building Division.
Sign below and skip the rest of the form
Owner' Signature: Date:
* No Go to Question 3.
3. Is water service permanently disconnected for your building?
❑ Yes Civil Code Sections 1 i 01.1 through 1101.8 do not apply. Sign below and skip the rest of the form.
Owner' Signature. c' hr r^ Date:/�/� Is
�i No Go to Question 4. �d fiy�p—J.([` (( I
4. Is your real property built and available for use or occupancy on or before January 1, 1994?
❑ No My real property is built and available for use or occupancy after January 1, 1994.
Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of/!the conn.
Owner' Signature: Date: S
is �J
4a Yes My real property is built an available for use or occupancy on or before January 1, 1994.
Civil Code Sections 1101.1 through 1101.8 apply. Refer to the attached.
El My property is a single-family residential real property. See Civil Code Section 1101.4.
On and after January 1, 2014, building alterations or improvements shall require all non-compliant plumbing
fixtures to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1,
2017, all non-compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless
of whether property undergoes alterations or improvements).
❑ My property is a multifamily residential real property. See Civil Code Section 1101.5.
On and after January 1, 2014, specified building alterations or improvements shall require non- compliant
plumbing fixtures to be replaced with water -conserving plumbing fixtures.
On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water -
conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or
improvements).
❑ My property is a commercial real property. See Civil Code Section 1101.5.
On and after January 1, 2014, specified building alterations or improvements shall require non- compliant
plumbing fixtures to be replaced with water -conserving plumbing fixtures.
SB407 2014.doc revised 03118/14
On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water- conserving
plumbing fixtures throughout the building (regardless of whether property undergoes alterations or
improvements).
I/We, the owner(s) of this property, certify under penalty of perjury that non-compliant plumbing fixtures have been replaced
with water -conserving plumbing fixtures in accordance with Civil Code Sections 1101.1 through 1101.8, the current
California Plumbing Code and California Green Building Standards Code, and manufacturer's installation requirements, and
that the water -conserving plumbing fixtures co 1 with the re uirements as indicated in the table below.
Owner's (or Owner Agent's) Signature: Date:
Upon completing and signing this Certificate, please return it to the Building Division in order to final your permit.
1. If the existing plumbing fixture water usage/flow rate is equal to or lower than the figure shown, it is not required to be upgraded.
SB4072014.doc revised 03/18/14
Non -Compliant P
_. _ Water -Conserving Plumbing Fixture.
Plumbing Fixture
(Fixture Complying with Current Code Applicable to New Construction)
Maximum Water Usage/Flow Rate
Fixture Type
Water Usage
2013 CPC Ch. 4
2013 CPC Ch. 4
2013 CPC Ch. 4
/Flow Rate
2013 CALGreen Div. 4.3
2013 CALGreen Div. 4.3
2013 CALGreen Div. 5.3
Single -Family
Multi -Family
Commercial
Residential
Residential
Water Closets
Exceed 1.6
Single flush toilets: 1.28 gallons/flush
(Toilets)
Gallons/flush
Dual flush toilets: 1.28 gallons/flush effective flush volume (the composite,
average flush volume of two reduced flushes and one full flush
Urinals
Exceed 1.0
0.5 gallons/flush
Gallons/flush
Showerheads
Exceed 2.5
2.0 gallons per minute @ 80 psi. Also certified to the performance criteria of
gallons per minute
U.S. EPA WaterSense Specification for Showerheads
(A hand-held shower is considered a showerhead.)
For multiple showerheads serving one shower, the combined flow rate of all
showerheads and/or other shower outlets controlled by a single valve shall not
exceed 2.0 gallons per minute @ 80 psi, or the shower shall be designed to
allow only one shower outlet to be in operation at a time.
Faucets —
Exceed 2.2 gallons
Maximum 1.5 gallons per
Within units:
0.5 gallons per minute @ 60
Lavatory
per minute
minute @ 60 psi; minimum
Maximum 1.5 gallons
psi
Faucets
0.8 gallons per minute @
per minute @ 60 psi;
20 psi
minimum 0.8 gallons
per minute @ 20 psi
In common and public
use areas: 0.5 gallons
per minute @ 60 psi
1.8 gallons per minute
60 psi
Faucets —
Exceed 2.2 gallons
1.8 gallons per minute @
1.8 gallons per minute
1.8 gallons per minute @ 60
Kitchen
per minute
60 psi
@ 60 psi
psi
Faucets
May temporarily increase
May temporarily
up to 2.2 gallons per
increase up to 2.2
minute @ 60 psi, and must
gallons per minute @
default to maximum
60 psi, and must
1.8 gallons per minute @
default to maximum
60 psi
1.8 gallons per minute
Where faucets meeting
@ 60 psi
.,, ._.. _ ..
the above are unavailable,
Where faucets meeting
aerators or other means
the above are
may be used to achieve
unavailable, aerators or
reduction.
other means may be
used to achieve
reduction.
1. If the existing plumbing fixture water usage/flow rate is equal to or lower than the figure shown, it is not required to be upgraded.
SB4072014.doc revised 03/18/14
Address /0 3 0 Z 0''(1
SMOKE / CARBON MONOXIDE ALARMS FILE
OWNER CERTIFICATE OF COMPLIANCE
COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION
10300 TORRE AVENUE • CUPERTINO, CA 95014-3255
(408) 777-3228 • FAX (408) 777-3333 • buildingaftupertino.org
Permit No. /�oDOy
PERMIT CANNOT BE FII\TALED AND COMPLETED UNTIL THIS CERTIFICATE
' HAS BEEN SIGNED AND RETURNED TO THE BUILDING DIVISION
PURPOSE
This affidavit is a self -certification for the installation of all required Smoke and Carbon Monoxide Alarms for
compliance with 2013 CRC Section R314,2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for
inspections are required.
GENERAL INFORMATION
Existing single-family and multi -family dwellings shall be provided with Smoke Alarms and Carbon
Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds
$1000.00, CRC Section R314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon
Monoxide Alarms be installed in the following locations:
AREA
SMOKE ALARM
CO ALARM
Outside of each separate sleeping area in the immediate vicinity of the
bedroom(s)
X
X
On every level of a dwelling unit including basements
X
X
Within each sleeping room
X
Carbon Monoxide alarms are not required in dwellings which do not contain fuel -burning appliances and that
do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with
CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal.
Power Supply: In dwelling units with no commercial power supply, alarm(s) may be solely battery operated.
In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do
not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl
space. Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2. An electrical permit is required for
alarms which must be connected to the building wiring.
As owner of the above -referenced property, I hereby certify that the alarm(s) referenced above has/have been
installed in accordance with the manufacturer's instructions and in compliance with the California Building
and California Residential Codes. The alarms have been tested and are operational, as of the date signed
below.
I have read and agree to comply with the terms and conditions of this statement
Owner (or Owner gents) Name:
Ct fro I ,(-
7
Si nature ............. . .......................................... Date: ..c .
Contractor Name:
lay✓ .,1.(�lC
.,x.6. s
Si nature..................................................Lic.# ........ 3............. Date:
/I
Smoke and CO forni.doc revised 03/18/14
solar
SolarEdge Single Phas(
For North America
SE300OA-US 1 SE38OOA-US / SE5O00A.
SE760OA-US / SE1000OA-US / SE114OO
���erier
25
i lea
wacca�C1 ;
r
4) — V
The best choice for SolarEdge enabled systems
= Integrated arc fault protection (Type 1) for NEC 2011 690.11 co li ATE
1
Superior efficiency (98%) ' ` 1 LLLL........
Small, lightweight and easy to install on provided bracket
Built-in module -level monitoring
m Internet connection through Ethernet or Wireless PLANNING DEPT
Outdoor and indoor installation
= Fixed voltage inverter, DC/AC conversion only CUPERTINO
= Pre -assembled AC/DC Safety Switch for faster installation
Optional built-in revenue grade meter
'F USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - AUSTRALIA- THE NETHERLANDS - ISRAEL www.solaredge.us
n.
solar' Single Phase Inverters for North America
• • Sc3000A-US % SE3300A-US i SE5000A-US / SE6000A-US!
SE760OA-US / SEt0000A-US / SE11400A-US
SE3000A-US SE3800A-US SE5000A-US SE6000A-US SE760OA-US SE1000OA-US SE11400ti-US
OUTPUT
i
9980 @ 208V ;-
-�-
--
Nominal AC Power Output
3300
3840
5000
(
6000 7680
101.000 @240V
11520
VA
5400 @ 208V !
10800 208V
I
Max. AC Power Output
3650
4150
5450@240V.i
1
6000 8350
.............. ..... ... .
10950@240V
I... ..............(....
12000
VA
AC Output Voltage Min. -Nom. -Max.* 1;
I
183 - 208 - 229 Vac
......................... ... I........-..
......!......
..........
..........
AC Output Voltage Min: Nom. -Max.*
j I
211- 240 - 264 Vac
I
...... ....
......
AC Frequency Min. -Nom. -Max.' j
�
59.3 - 60 - 60.5 (wi1.th HI country setting 57 - 60 - 60.5)
..... .
Hz
1
Max Continuous Output Current
14
16
24 @ 208V '
25 32
48 @ 208V
48
A
21 @ 240V
42 @ 240V
GFDI............ .�.
. ............1..
.. .............,...
.....................
...........I...........
....... I — . _...
Utility Monitoring, Islanding E
I
Protection, Country Configurable
Yes
Thresholds I
--
----.----
------
INPUT
- -- ----- - -------4-
DPower**
Recommended Max. C
--,-4100
i
--4800
-
---
--- --i- -
-
(STC) .......... ..... .. . . ..... ....................... ...............I.................
6250
7500 9600 I
12400
14400
W
Transformer -less, Ungrounded j
Yes
Max. Input Voltage
.
500 ...............................
........
.....-.......
Vdc
..............................................
Nom. DC Input Voltage j
........ ...................................
.....
325 @ 208V / 350 @ 240V
.. .... .....- -- - .....................-......
_.... ...
..
Vdc
j
116.5@01208V
33 @ 208V
Max. Input Current"'
..........
it
...... ...
13
15.5 @ 240V. - I
18 j 23.5
.......
.305 @ 240V
35
Adc
Max. Input Short Circuit Current
30
!
45
Adc
Reverse -Polarity Protection
.....
Yes .........................
....... ..................
..........
... . ..........I..... .. ............
Ground -Fault Isolation Detection ...
.......
- ..........i...........
..
600ku Sensitivity
..........I..................
...........
....................................I
Maximum Inverter Efficiency
97.7 !
98.2
�.
98.3
98.3
I........
98
98
98
%
..........................................................................
.....
197.5 @ 208V
..
...........
1
....I.............................
97 08V
CEC Weighted Efficiency
...... .....
97.5
98
i
1.. 98C�240V .'
97.5
97.5
I.................._....-.......(..97.5@240V..;..................I..........
97.5
%
Nighttime Power Consumption
_ -- -
< 2.5
<4
W
ADDITIONAL FEATURES
Supported Communication Interfaces .........................................................P.......
..............I..........................
RS485, RS232, Ethernet, ZigBee (optional)
,...............
............. ....
I......
Built-in Revenue Grade Meter I
Optional
a truvvnts� a.vmrursna.c
Safety -r- . , .. UL1741, UL16998, UL1998 , CSA 22.2
I
Grid Connection Standards i IEEE1S47
. ......_ ...... ......... ...i..................................... ............ ... _...,.......... ................................ ..... .... ......... ......
Emissionsp_ _ -- _ FCC art1S class B - Y- l
INSTALLATION SPECIFICATIONS _
AC output conduit size / AWG range 1; 3/4" minimum/ 24-6 AWG { 3/4" minimum/ 8-3 AWG
DC input conduit size / q of strings / I 3/4" minimum / 1-2 strings / 24-6 AWG -3/4" minimum / 1-2 strings / 14-6 AWG
AWGrange ........... .............. ...�................ -... ... ....... .....,...................................... ............... I.......... ...........
Dimensions with AC/DC Safety 30.5 x 125 x 7 / 30.5 x 12.5 x 7.5 / in/
Switch (HxWxD) ! 775 x 315 x 172 775 x 315 x 191 x 10.5 / 775 x mm
. ... ....................... ...
Weight with AC/DC Safety Switch S1.2 / 23.2 ! 54.7 / 24.7 12 5 88 A / 40.1 ' 315 ' Ib / k$
x z
................... _. . ..... ..... .. .... ...... ....
Cooling Natural Convection Fans (user replaceable)
...........
... ........ .. _......................... ................. ...... ................. ...........
Noise < 25 I < 50 I dBA
. ... _ ..................................I... . . ...................... _.........................---................................I...........
Min: Max. Operating Tempera ture
-13 to +140/ -25 to +60 (CAN version,*** -40 to +60) I 'F /'C
Range
Protection Ratin gNEMA 3R
. ............ . - ............................ ....... ..... ................ ...............
i...........
• For other regional settings please contact SolarEdge support.
•• limited to 125% for locations where the vearH average high temperature is above 77'F/25 C and to 135% for locations where it is below 77'F/25'C.
For detailed information, refer to httoJ/www.solaredee.us/files/odfs/inverter do oversiymt euide.odf rA 0
• 21.5% efficiency
Ideal for roofs where space is at a premium or
where future expansion might be needed.
Maximum performance
Designed to deliver the most energy in
demanding real world conditions, in partial
shade and hot rooftop temperatures. '• 2.3
• Premium aesthetics
SunPower®Signature' Black X -Series panels
blend harmoniously into your roof. The most
elegant choice for your home. .
moxeon® Solar Cells: Fundamentally better.
Engineered for performance, designed for durability
Engineered for peace of mind
Designed to deliver consistent,trouble-free
energy over a very long lifetime.a,s
Designed for durability
The SunPower Maxeon Solar Cell is the only
cell built on a solid copper foundation. Virtually
impervious to the corrosion and cracking that
degrade Conventional Panels.a,s
Same excellent durability as E. -Series panels.
# 1 Ranked in Fraunhofer durability test:'°
100% power maintained in Atlas 25+
comprehensive PVDI Durability test."
UNMATCHED PERFORMANCE, RELIABILITY & AESTHETICS
SIGNATURETM BLACK ; X21 345 PANEL
X21 - 335 PANEL
HIGHEST EFFICIENCY°� rOFt LODE LnMp��ANMI✓
Generate more energy per square foot
X -Series residential panels convert more sunlight to electricity producing 44
more power per panel,' and 75% more energy per square foot over 25
years -3.4
HIGHEST ENERGY PRODUCTION 7
Produce more energy per rated watt
High year one performance delivers 8-10% more energy per rated waft .3
This advantage increases over time, producing 21 % more energy over the
first 25 years to meet your needs.'
a
120%.21%
-------------
-------
I Power at High Temps
More
Energy
c
110%
Per Rated. Watt
5
100%
Degradation
Q
• - - -
High Average Watts
90%
4%
a
Better. low --Light and "`-----
rn
80%
Spectral Response
m
LU
-------
Co-ive-itio-Ewl
0 60%
N 50%
0 5 10 15 20 25
Years
--- --- - -- -- - ---
j Maintains High
36% more,
year 25
�5,�-1ERGY pf��
PHOTON;
'o-'2F_160�,
A—d.d to
SwPow.r ES.rie,.
ma....qY.,
sunpowercorp.com
8,�
-------
I Power at High Temps
m---------
No Lightlnduced
0
6%
---------
.."---
Degradation
Q
High Average Watts
4%
---------
Better. low --Light and "`-----
`c
Spectral Response
2%
-------
--------
a
Anti-Reflective
Anti -Reflective Glass
36% more,
year 25
�5,�-1ERGY pf��
PHOTON;
'o-'2F_160�,
A—d.d to
SwPow.r ES.rie,.
ma....qY.,
sunpowercorp.com
100%
95%
90%
85%
80%
75%
6WER AND PRODUCT WARRANTY
SUNPOWER OFFERS THE BEST COMBINE"j
POWER WARRANTY
7 5 10 15 20 25
Years
More guaranteed power: 95% for first 5 years,-0.4%/yr, to year 25. a
ELECTRICAL DATA
Temperature
— 40'F to +I 85'F (— 40aC to +85'C)
X21-335-BL.K
X21-345
Nominal Power12 (Pnom)
335 W
345 W
Power Tolerance
+5/-0%
+5/-0%
Avg. Panel Efficiency11
21.1%
21..5%
Rated Voltage (Vmpp)
57.3 V
57.3 V
Rated Current (Impp)
5.85 A
6.02 A
ltage (Voc)
67.9 V
68.2 V
EShort-Circuitrrent (Isc)
6 .23 A
6.39 Am
Voltage
600 V UL; 1000 V JEC
s Fuse
20A
Power Temp Coef. (Pmpp)
—0.30% / aC
Voltage Temp Coef. (Voc)
—167.4 mV / aC
Current Temp Coef. (Isc)
3.5 mA / IC
REFERENCES:
1 Al comparisons are SPR -X21-345 vs. a representative conventional panel: 240W,
approx 1.6 m2, 15% efficiency.
2 PVEvolution Labs "SunPower Shading Study," Feb 2013.
3 Typically 8-10% more energy per watt; BEW/DNV Engineering "SunPower Yield Report"
Jan 2013, with CFV Solar Test Lab Report #12063, Jan 2013 temp. coef. calculation.
4 SunPower 0.25%/yr degradation vs. 1.0%/yr conv. panel. Campeau, Z. et al. "SunPbwer
Modple Degradation Rate," SunPower white paper, Feb 2013; Jordan, Dirk "SunPower
Test Report" NREL, Oct 2012.
5 "SdhPower Module 40 -Year Useful Life" "SunPower white paper, Feb 2013. Useful life is
99 out of 100 panels operating at more than 70% of rated power.
6 Nigher than E Series which is highest of all 2600 panels listed in Photon Intl, Feb 2012.
7 1 % more energy than E -Series panels, 8% more energy than the average of the top 10
panel companies tested in 2012 (151 panels, 102 companies), Photon fnPI, Mar 2013.
8 Compared with the top 15 manufacturers. SunPower Warranty Review, Feb 2013.
9 Some exclusions apply. See warranty for details.
10 X -Series same as E -Series, 5 of top 8 panel manufacturers were tested by Fraunhofer
ISE, "PV Module Durability Initiative Public Report," Feb 2013.
11 Compared with the non-chess-tesfed control panel. X -Series some as E -Series, tested in
ANos 25+ Durability test report, Feb 2013.
12 Standard Test Conditions (1000 W/m2 irradiance, AM 1.5, 25" C).
13 Based on average of measured power values during production.
PRODUCT WARRANTY
5 10 15 20 25
Years
Combined Power and Product Defect 25 year coverage
that includes panel replacement costs.'
OPERATING CONDITION AND MECHANICAL DATA
Temperature
— 40'F to +I 85'F (— 40aC to +85'C)
Max load
Wind: 50 psf, 2400 Pa, 245 kg/m2 front & back
Snow: 112 psf, 5400 Pa, 550kg/m2 front
Impact
i resistance
1 inch (25 mm) diameter hail at 52 mph (23 m/s) I
Appearance
Class A+
Solar Cells
96-Monocrystalline Maxeon Gen III Cells
Tempered Glass
High Transmission Tempered Anti -Reflective
.function Box
IP -65 Rated
Connectors
MC4 Compatible 1
Frame
Class 1 black anodized, highest AAMA Rating
Weight
41 lbs (18.6 kg) l
1046mm
[41.2in]
46mm
[1.81 in] 1559mm
[61.4in]
See htta://www.sunpowermm.com/facts for more reference information.
For further details, see extended dotasheet: www.sunpowercoro.com/daiushecits Read safety and installation instructions before using this product.
O April 2013 SunPower Coryomlion. AN rights miwmd. SUNPOWER, the SUNPOWER 1090,. MAXEON, MORE ENERGY. FOR UFE., and SIGNATURE oro trademarks or mgW@md trademarks of SunPa mr
Corporation. Specifications induded in this dabsh"t aro subject to change without natia. - su n powe rco rp. com
D --.t # 504828 Ra. A ATR EN
TESTS AND CERTIFICATIONS
j Standardtests
UL 1703, IEC61215,IEC 61730
Quality tests
ISO 9001:2008, ISO 1.4001:2004 j
EHS.Compliance
ROHS, OHSAS 18001:2007, lead-free j
Ammonia test
IEC 62716 !I
Salt Spray test
IEC 61701 (passed maximum severity)
PID test
Potentiol4nduced Degradation free: 1000V 10
Available listings
- CEC,-UL, TUV, MCS
1046mm
[41.2in]
46mm
[1.81 in] 1559mm
[61.4in]
See htta://www.sunpowermm.com/facts for more reference information.
For further details, see extended dotasheet: www.sunpowercoro.com/daiushecits Read safety and installation instructions before using this product.
O April 2013 SunPower Coryomlion. AN rights miwmd. SUNPOWER, the SUNPOWER 1090,. MAXEON, MORE ENERGY. FOR UFE., and SIGNATURE oro trademarks or mgW@md trademarks of SunPa mr
Corporation. Specifications induded in this dabsh"t aro subject to change without natia. - su n powe rco rp. com
D --.t # 504828 Ra. A ATR EN
25800 Commercentre Drive
Lake Forest, CA 92630 USA
Telephone: 949.448.4100
Facsimile: 949.448.4111
www.intertek.com
In the basis of the tests undertaken, the sample(s) of the below product have been found to comply with the requirements of
the referenced specifications at the time the tests were carried out.
t-1 IPEKI INU
Name &
Address:
Product Description:
Ratings & Principle
Characteristics:
Models:
Brand Name:
Relevant Standards:
Verification Issuing Office:
Date of Tests:
Test Report Numberl
Professional Solar Products, Inc.
1551 S. Rose Avenue
Oxnard, CA 93033
Photovoltaic Racking System, Roof System
Fire Class Resistance Rating:
-Class A for Steep Slope Al
Rooffrac
when u
APR 07215
Cai�F COMPLIANCE
REV;EV
aev�ewe� tsy �
1 and Type 2, Listed Photovoltaic Modules.
NroSolar
UL Subject 2703 (Section 15.2 and 15.3) Outline of Investigation for Rack Mounting Systems and
Clamping Devices for Flat -Plate Photovoltaic Modules and Panels, Issue Number: 2, Nov 13, 2012
Referencing UL1703 (Section 31.2) Standard for Safety for Flat -Plate Photovoltaic Modules and
Panels, May 20, 2014
Intertek Testing Services NA, Inc.
25800 Commercentre Dr.
Lake Forest, CA 92630
12/12/2014 through 12/30/2014
100779407LAX-003
This verification is part of the full test report(s) and should be read in conjunction with them. This report does not automatically
imply product certification.
Completed by: Michael Hoffnagle
Title: PV Engineer
Signature:
Date: 02/23/2015
Reviewed by: Amar Ka cel
Title: Reviewer
Signature:
Date: 02/24/2015
This Verification is for the exclusive use of lntertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are
limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement for any loss, expense
or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its -
marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results
referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever beer
under an Intertek certification program.
GFT -OP -11a (24 -MAR -2014)
CERTIFICATE OF COMPLIANCE
Certificate Number 20150223-E246423
Report Reference E246423-20040917
Issue Date 2015 -FEBRUARY -23
Issued to: SUNPOWER CORP
77 RIO ROBLES
SAN JOSE CA 95134
This is to certify that PHOTOVOLTAIC MODULES AND PANELS
representative samples of (See addendum for additional information.)
Have been investigated by UL in accordance with the
Standard(s) indicated on this Certificate.
Standard(s) for Safety: UL 1703, 3rd Edition, revised May 20, 2014, "Standard for
Safety for Flat -Plate Photovoltaic Modules and Panels."
Additional Information: See the UL Online Certifications Directory at
www.ul.com/database for additional information
Only those products bearing the UL Listing Mark for the US and Canada should be considered as
being covered by UL's Listing and Follow -Up Service meeting the appropriate requirements for US
and Canada.
The UL Listing Mark for the US and Canada generally includes: the UL in a circle symbol with "C" and
"US" identifiers:(61)°S the word "LISTED",- a control number (may be alphanumeric) assigned by UL.-
and
L;and the product category name (product identifier) as indicated in the appropriate UL Directory.
Look for the UL Listing Mark on the product.
C uV:iERTINO
;q°jv`:lulnc Department
"! ��'� 7 20►�
cars• u,r,hcE
�,EVIE�`�r U FOR CODS
avieu4���1 3y.
William R. Camey, Director, North American Certification Programs ■
UL LLC L
Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at w—ul.con✓comact-
Page 1 of 2
CERTIFICATE OF COMPLIANCE
Certificate Number 20150223-E246423
Report Reference E246423-20040917
Issue Date 2015 -FEBRUARY -23
This is to certify that representative samples of the product as specified on this certificate were tested
according to the current UL requirements.
Photovoltaic Modules:
Models XXX -440 to -410, -408, -405, -402, -400, -398, -395, -392, -390, -388 —385, -382, -380, -375, -
345 to -293, -290, -285, -280, -250 to -225, followed by E or NE, may be followed by -BLK or —WHT,
followed by -D, -I, or—U, where XXX represents SPR or SPV.
Models XXX-EYY-### where XXX represents SPR or SPV, YY represents 18, 19, 20 or 21 and ### is
any number from 440 to 375 or 345 to 285 or 250 to 225 and may be followed by —COM and/or -BLK
Models XXX -450 to -435, XXX -345 to -311, XXX -262 to -233 followed by J, NJ, NX or X, may be
followed by -BLK or -WHT, followed by -D, -1, -or -U, where XXX represents SPR or SPV.
Models XXX-XYY-### where XXX represents SPR or SPV, YY represents 18, 19, 20 or 21 and ### is
any number from 486 to 435 or 365 to 310 or 274 to 233 and may be followed by —COM and/or —BLK
Flat -Plate Photovoltaic Modules with construction compliant to Module Fire
Performance Type 2.
CVpr ,partnont
,;1V0d'1n9
Rev1e\,N 13y
William R. Carney, Director, North American Certification Programs ■
UL LLC L
Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at vrvw.ul.contfconmcul
Page 2 of 2
A
CITY OF CUPERTINO
10300 Torre Avenue Telephone 777-3228
INSPECTION NOTICE
BUILDING DIVISION
JOB DATE
ADDRESS TIME
DAILY REPORT:a CORRECTION NOTICE -J" VIOLATION C3
TYPE INSR: BLDWEI ELEC. L) PLBG.0 MECH.:1
Ll STOP WORK Ll REINSPECTION FEE I
WEATHER---INSP.
CARD TO REMAIN ON .1.013 -SITE
3
CITY OF CUPERTINO BUILDING PERMIT INSPECTION CARD
BUILDING ADDRESS: 10382 MIRA VISTA RD
coNTPuCTOR: POLO SOLAR
PERMIT NO: 15040047
OWNER'S NAME: STANEK MICHAEL W AND CAROL
3345 KELLER ST
DATE ISSUED: 04/07/2015
OWNER'S PHONE. 4082652311
SANTA CLARA, CA 95054
PHONE NO: (408) 970-0680
F F I— �—
BUILDING PERMIT INFO: BLDG ELECT PLUMB MECH
RESIDENTIAL COMMERCIAL
JOB DESCRIPTION: INSTALL (14) PANEL PV SYSTEM ON SFDWL 4.8 KW
\ -
FOUNDATION/PIERS/H D S
UFER GROUNDI—
TBACK-CERT
GARAGE SLABS/PREGUNITE
UNDERGROUND/SLAB
UNDERGROUND PLUMBING
UNDERGROUND ELECTRICAL
UNDERFLOOR PLUMBING
UNDERFLOOR MECHANICAL
WILDLAND URBAN INTERFACE FIRE AREA ER#
TO ARRANGE INSPECTION
Call 777-3228 between 7:30 am and 3:30 pm Monday through Friday, at least 24 hours
before required inspection. Job address and Permit Numbers are needed when
requesting an inspection.
CUPERTINO SANITARY DISTRICT
Closed circuit video inspection of property line cleanout, point of connection
and street lateral required prior to passing FINAL CITY PLUMBING
INSPECTION. Call the District (408-253-7071) for an appointment.
NO BUILDING FINALS INSPECTIONS UNTIL ALL REQUIRED
BUSINESS LICENSES ARE OBTAINED
PERMIT EXPIRES IF WORK IS NOT STARTED WITHIN 180 DAYS OF PERMIT
ISSUANCE OR 180 DAYS FROM LAST CALLED INSPECTION.
IMPORTANT
When a permit has expired, a charge totaling one-half the fees to obtain a new permit
must be paid in order to reactivate the permit. If a permit has been expired for more
than one year, a charge totaling the full fees to obtain a new permit must be paid
to reactivate the permit
NOTES:
SPECIAL INSPECTIONS Inspector: Date:
ROOF INSPECTIONS
PRE -INSPECTION: Inspector: Date:
TEAR -OFF: Inspector: Date:
PLYWOOD: inspector: Date:
BATTENS: Inspector: Date:
IN PROGRESS: Inspector: Date:
FINAL: Inspector: Date:
NOTE: OSHA APPROVED ACCESS TO ROOF SHALL BE PROVIDED FOR INSPECTION.
OCCUPANCY OF BUILDING NOT PERMITTED UNTIL BUILDING FINAL IS SIGNED BY
INSPECTOR
UNDERFLOOR ELECTRICAL
UNDERFLOOR FRAMING VENTS
UNDERFLOOR INSULATION
PYAEF
ROOF SHEATHING
ROUGH PLUMBING
TUBS & SHOWER PAN
ROUGH MECHANICAL
ROUGH ELECTRICAL/POOL BOND
FRAMING/STAIRS/E. EGRESS
WSULATION/VENTILATION
Clvaw ' '� ;. IIA_ �
EXTERIOR SHEAR/NOLD DOWN
INTERIOR SHEAR/HOLD DOWN
SHEETROCK/SHEETROCK SHEAR
EXTERIOR LATH/W-SCREED
INTERIOR LATH
NO TAPE A51BR .HEI i1i SLGNED . .,
SCRATCH COAT
SEWERIWATER
ABOVE CE1L
�Tv--B�AR/MECH/ELECT
ELECTRIC METER RELEASE
GAS TEST/METER RELEASE
GRADE -PUBLIC WORKS
FIRE - CALL (408) 3784010
PLANNING (408) 777-3308
SANITARY (408) 253-7071
ELECTTRICAL
J
MECHANICAL
PLUMBING
HANDICAP
ENERGY
BUILDING
,S•1l•1
CERTIFICATE OF OCCUPANCY
i
2 Strings w/7 Ea.
SunPower #10 XLP USE -2
SPR -x21-345 3/4" EMT -
W/ #10 Bare 4 ea. #10 THWN-2
Copper Bond w/ #10 Ground
7 ea.
J -Box
7 ea.
Voltage and Current:
2 Strings w/ 7 ea. in Parallel
Max. Power 4830 Watts DC
Max. Power Voltage DC 477.4 Voc
(x temp coefficient) 596.8 Voc
Max. Power Current 18 Isc
(x 1.25 irradiance) 22 Isc
Sunnower SPR -x21-345
Peak Power Watts :
345 W
Max. Power Voltage :
57.3 Vmp
Max. Power Current
6.02 Imp
Open Circuit Voltage :
68.2 Voc
Short Circuit Current :
6.39 Isc
nek, Mike & Carol
0382 Mira Vista Rd.
upertino, CA 95014
3/4" EMT -
3 ea.#8 THWN w/ Meter
#8 Ground
Solar Edge
SE -5000A -US [200 Amp Main w/
(240v)
Inverter
with
Disconnect
CUPERTINO
�iuirdinq DeoariTrPn?
APR 0 7 2015
FOH CODk COMPLIANCE
<PviPwed F3yi � -
Grounding and Bonding
30 Amp Load
Side Solar
Breaker
All Modules, Rail, Boxes, and Conduit will
have a Continued Bond with #10 Bare
Copper and DB Copper Lugs .
All bonding and Grounding will Comply
with Article 690.41-690.49
Inverters:
Solar Edge
SE500OA-US
Input: DC
Max. Power
6750 Watts
Max. DC Voltage
500 Volts
Max. Current DC
45 Amps
Output: AC
Max. Power
5000 Watts
Max. Current AC
21 Amps
Weight
54.7 Lbs
Poco Solar Inc.
3345 Keller Street
Santa Clara, Ca. 95054
265-2311 1 Lic. # 879366
All Warning Labels Shall Conform to UL 969, White Labels, Red Lettering
Installation Shall be in Full Compliance of the Following Codes:
a. 2013 California Building Code (2012 IBC)
b. 2013 California Residential Code (2012 IRC)
c. 2013 California Electrical Code (2012 NEC)
d. 2013 California Fire Code
All electrical equipment
shall meet the 2012
CEC 110.26 required
working clearances and
accessibility
Meter/Main w/
Warning Labels
All PV Equipm4
Marked with We;
Resistant Warnin
Guidance Lane..
Inverter, AC/DC
Disconnects w/
Warning labels
Conduit Routed
on Roof with Signage stating:
nek, Mike & Carol
0382 Mira Vista Rd.
Cupertino, CA 95014
408) 265-2311
U
Clearance
O
Auess
Pathway
Attachment
Points
Driveway
0
Access
❑E
W
Z fn
14 Flush Roof Mounted PV Modules
Roof: 1 Stories Material: Single Layer Comp.
Planes: 270 Pitch: 5/12
Rafters: 2" x 6" Spacing: 16" O.C.
Fast Jacks Lagged into Rafters
with a Minimum of 2 1/2" Embedment
SunPowerSPR-345NE-WHT-D
17.1 Sq. Ft. 41 Lbs 2.4 Lbs per Sq. Ft.
3.03 Lbs per Sq. Ft. W/ Hardware and Rails
725.4 Max. Lbs
Attachment Points: 32
Lbs Per Attachment: 22.7
Existing Pool Solar
Heating Panels
74C;;(.2 Cj?e—
��G C
Rail
6'4gALTi-rJ n-�Jnli C.�17h
`�'uiERTINO
wilding Department
APR 0 7 2015
REVIEwc- 0 F :'t CODE COMPLIANCE
iZeviewed By
Vista Road
3345 Keller Street
Santa Clara, Ca. 95054
yP
_ a Lic. # 879366
Egg d
l So �OD.�
0
FFS
c ,