Loading...
B-2016-1760CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO: B-2016-1760 21835 ALMADEN CIR CUPERTINO, CA 95014-2803 (357 15 088) WEST COAST SOLAR INC BRENTWOOD,CA 94513 OWNER'S NAME: DYER BRUCE T TRUSTEE & ET AL DATE ISSUED: 04/13/2016 OWNER'S PHONE: 925-516-3900 PHONE NO: (925) 516-3900 LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO: License Class C-46, C-39 Lic. #908549 Contractor WEST COAST SOLAR INC Date 12/31/2017 X BLDG X ELECT —PLUMB I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing MECH X RESIDENTIAL COMMERCIAL with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. JOB DESCRIPTION: INSTALL (N) PV SOLAR ARRAY SYSTEM FLUSH -MOUNTED I hereby affirm under penalty of perjury, one of the following two declarations: DIRECTLY TO THE ROOF - 3.64 KW AND 14 MODULES n. I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 7-0 I have and will maintain Worker's Compensation Insurance, as provided for by Or Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Sq. Ft Floor Area: Valuation: $12000.00 APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Date 4/13/2016 OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: n. I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) 2. I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.7044, Business & Professions Code). I hereby affirm under penalty of perjury one of the following three declarations: n. I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I trust forthwith comply with such provisions or this permit shall be deemed revoked. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Signature Date 4/13/2016 APN Number: Occupancy Type: 357 15 088 PERMIT EXPIRES IF WORK IS NOT STARTED WITHIN 180 DAYS OF PERMIT ISSUANCE OR 180 DAYS FROM LAST CALLED IN ECTION. Issued by: Alex Valleluneaa:* :: ? Date: 04/ 13/2016 RE -ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. Signature of Applicant: Date: 4/13/2016 ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER HAZARDOUS MATERIALS DISCLOSURE I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quatity Management District I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Sections 25505, 25533, and 25534. Date: 4/13/2016 6;1� �� CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name Lender's Address ARCHITECT'S DECLARATION I understand my plans shall be used as public records. Licensed Professional CUPERTINO CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • buildingc@-cupertino.org ❑ NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION / TI ❑ REVISION / DEFERRED L)' U - 1--+ 6 U ORIGINAL PERMIT # PROJECT ADDRESS Azdpe-j C/1 r APN # If_ 141t_15 __,6 OWNERNAME 7 PHONE q�� r 3c4 4 E-MAIL e-t- STREET ADDRESS CITY, STATE, ZIP FAX Adle CONTACT NAME O PHONE- �_ �i� /� 6 E-1 L f O�/%/� 60/7 STREET ADDRESS . CITY, STATE, ZIP S/ FAX 2/ IA) .c cdOd SZS - /G - 3 q 3 ❑ OWNER ❑ OWNER-BU DER ❑ OWNER AGENT ❑ CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME LICEN E NUMBER LICENSE TYPE BUS. LIC # sus � - 3 CO ANY NAME AICS r- t'o sT oz,44- E- &260 & wesrCOAS7-S*4064 44 cow FAX 39Zj - _5 6 - 3 9.3 S< STREET ADDRESS C STATE, // PHONE a K/ /� . (J / � — � V ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS. LIC # COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE DESCRIPTION OF WORK /0'W OLY (A) 5k DA OQ Q A EXISTING USE PROPOSED USE CONSTR. TYPE # STORIES USE TYPE OCC. SQ.FT. VALUATION ($) EXISTG NEW FLOOR DEMO TOTAL AREA AREA AREA NET AREA BATHROOM KITCHEN OTHER REMODEL AREA REMODEL AREA REMODEL AREA PORCH AREA DECK AREA TOTAL DECK/PORCH AREA GARAGE AREA: LJDETACH ATTACH # DWELLING UNITS: IS A SECOND UNIT ElYES SECOND STORY ❑YES BEING ADDED? []NO ADDITION? []NO PRE -APPLICATION ❑ YES IF YES, PROVIDE COPY OF IS THE BLDG AN ❑ YES RECEIVED BY: TOTAL VALUATION: PLANNING APPL # ❑ NO PLANNING APPROVAL LETTER EICHLER HOME? ❑ NO �DC By my signature below, I certify to each of the following: I am the property owner or authorized agent to At on the p operty owner's behalf. I h ve read this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to building construction. I authorize representatives of Cupertino to enter the above-identifiedpropertyfor inspection purposes. Signature of Applicant/Agent: Date: EN SUPPLEMT ORMATI QUIRED PLAN CHECK TYPE ; " ROUTING SLIP _ New SFD or Multifamily dwellings: Apply for demolition permit for ❑ ovER THE-coulvTEltu - -�,q� REVIEW existing building(s). Demolition permit is required prior to issuance of building "EXPRESS ` '- " 09. (RE/ permit for new building. ❑` PLANNING REVIEW _ Commercial Bldgs: Provide a completed Hazardous Materials Disclosure ❑. STANDARD ." ❑ PUBLICwORKS form if any Hazardous Materials are being used as part of this project. ❑ LAtGE ❑ FIRE DEPT _ Copy of Planning Approval Letter or Meeting with Planning prior to ❑ MAJOR ❑ SANITARY SEWER DISTRICT submittal of Building Permit application. ❑ ENVIRONMENTAL HEALTH B1dgApp 2011.doc revised 06121111 GENERAL NOTES 1. ALL ELECTRICAL MATERIALS SHALL BE NEW AND LISTED BY RECOGNIZED ELECTRICAL TESTING LABORATORY CUSTOM MADE EQUIPMENT SHALL HAVE COMPLETE TEST DATA SUBMITTED BY THE MANUFACTURER ATTESTING TO ITS SAFETY 2. OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED 3. ALL METALLIC EQUIPMENT SHALL BE GROUNDED 4. ALL SPECIFIC WIRING IS BASED ON THE USE OF COPPER. 5. CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS PRIOR TO INSTALLATION AND SHALL COORDINATE ALL INSPECTIONS, TESTING COMMISSIONING AND ACCEPTANCE WITH THE CLIENT, UTILITY CO. AND CITY INSPECTORS AS NEEDED. 6. THE ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS OF SERVICE POINTS AND SERVICE SIZES WITH THE SERVING UTILITY COMPANY AND COMPLY WITH ALL UTILITY COMPANIES REQUIREMENTS. IF THE SOLAR BACK FED BREAKER IS VOER THE BUSS SIZE 20% LIMIT, CONTRACTOR SHALL INCLUDE THE COST TO REPLACE MAIN BREAKER OR ENLARGE MAIN CAPACITY. 7. DRAWINGS ARE DIAGRAMMATIC ONLY, ROUTING OF RACEWAYS SHALL BE OPTION OF THE CONTRACTOR UNLESS OTHERWISE NOTED AND SHALL BE COORDINATED WITH OTHER TRADES. 8. IF THE ROOF MATERIAL OR ROOF STRUCTURE NOT ADEQUATE FOR PV INSTALLATION, CALL ENGINEER PRIOR TO INSTALL. THE CONTRACTOR IS RESPONSIBLE TO VERIFY THAT THE ROOF IS CAPABLE OF WHITSANDING THE EXTRA WEIGHT. 9. IF THE DISTANCES FOR CABLE RUNS ARE DIFFERENT THAN SHOWN, THE CONTRACTOR SHALL NOTIFY THE ELECTRICAL ENGINEER TO VALIDATE THE SIRE SIZE. FINAL DRAWINGS WILL BE RED -LINED AND UPDATED AS APPRPRIATE. 6. ALL PV MODULES AND ASSOCIATED EQUIPMENT AND WIRING SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE. 7. LIVE PARTS OF PV SOURCE CIRCUITS AND PV OUTPUT CIRCUITS OVER 150V TO GROUND SHALL NOT BE ACCESSIBLE TO OTHER THAN QUALIFIED PERSONS WHILE ENERGIZED. 8. INVERTER IS EQUIPED W/ INTEGRATED GFDI, THUS PROVIDING GROUND FAULT PROTECTION 9. ALL CONDUCTORS SHALL BE COPPER AND 90 DEG RATED 10. ALL ELECTRICAL EQUIPMENT SHALL BE LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY OR APPROVED BY THE DEPARTMENT. 11. CONDUITS SHOULD BE PAINTED TO MATCH EXISTING ROOF AND WALL COLORS 12. ALL WORK SHALL BE IN ACCORD WITH THE 2013 CBC, 2013 CEC AND 2011 NEC WITH SPECIAL ENPHASIS ON ARTICLE 690 13. A SINGLE CONDUCTOR SHALL BE PERMITTED TO BE USED TO PERFORM THE MULTIPLE FUNCTIONS OF DC GROUNDING, AC GROUNDING AND BONDING BETWEEN AC AND DC SYSTEMS AS PER NEC 690.47(C) AND SIZED AS PER SEC 250.122 14. EQUIPMENT GROUND CONDUCTOR REQUIRED IN RACEWAYS SIZED PER CEC 250-122. 15. PER ART 250.92. NON -CURRENT CARRYING METAL PARTS OF EQUIPMENT SHALL BE EFFECTIVELY BONDED TOGETHER. BOND BOTH ENDS OF RACEWAYS 10. WHENEVER A DISCREPANCY IN QUALITY OF EQUIPMENT ARISES ON THE DRAWING OR SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES REQUIRED CODV.' BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN THE SPECIFICATIONS TO ENSURE COMPLETE COMPLIANCE AND LONGEVITY OF OFFICE THE OPERABLE SYSTEM REQUIRED BY THE ARCHITECT/ENGINEERS. 11. ALL BROCHURES, OPERATION MANUALS, CATALOGS, SHOP DRAWINGS, ETC. SHALL BE HANDED OVER TO OWNER'S REPRESENTATIVE AT THE COMPLETION OF WORK PHOTOVOLTAIC NOTES: SHEET INDEX 1 1 1 ROOF PLAN 2 SINGLE LINE DIAGRAM 3 CODE REQUIRED SIGNAGE 4 ATTACHMENT LAYOUT 5 INVERTER MAP 6 MODULE MAP 7 INVERTER DATA SHEET 8 MODULE DATA SHEET 9 MODULE CERTIFICATION 10 RACKING DATA SHEET 11 RACKING CERTIFICATION 12 ATTACHMENT DATA SHEET CUP RTIICIO Building C)epartment R 'j, -11 INSTALLER West Coast Solar AridrPsc- 2155 Elkins Way, Suite F Brentwood, CA 94513 Phone Number: 925-516-3900 Lic 908549 Class C, C-46, C-39 WEST C 0 A S T tYC, DESIGNER NAME: DAVID D. DATE: 13 APRIL 2016 THE IN � POWER SYSTEMtASt%T�2ALL COMq.PLY) WT�H T LLOWING CODES: 2013 CALIFORRI✓ RG?111`9PAL RxECEIVED v% 2013 CALIFORNIA RESIDENTIAL CODE 2013 CALIFORNIA BUILDING CODE APR 1 Lll iJ 2013 CALIFORNIA GREEN BUILDING STANDARDS CODE C99 2013 CALIFORNIA ENERGY CODE 2013 CALIFORNIA MECHANICAL CODE ��-. 2013 CALIFORNIA PLUMBING CODE ALL OTHER ORDINANCE ADOPTED BY THE LOCAL GOVERNING AGENCIES PROJECT NAME: Joan Thompson Dyer COMMUI JITY DEVELOPMENT DEPART2.11e35 Almaden Ave, Cupertino, CA 95014 BUI - 1. ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULAis set of plan SHALL BE TESTED, LISTED AND IDENTIFIED UL 170pbsiteduring changes c 2. SOLAR SYSTEM SHALL NOT COVER ANY PLUMBING OR MECHAW,,&4rom, -wit VENTS The stamping o 3. MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED. be held to per 4. SOLAR INVERTER MUST HAVE A MANUFACTURE of any provisk INSTALLED DISCONNECTING MEANS THAT PREVENTS PARALLEL FEEDING UTILITY LINES DURING POWER OUTAGE. BY 5. REMOVAL OF AN INTERACTIVE INVERTER OR OTHER EQUIP"11ENT­ SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEE!fffHE NO. GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTORS. D d specifications MUST be kept at h� struction. It is unlawful to msake-any , orations on'same, or to deviate. approval from t ' - ' 47ng Official. s purr and specifications SHALL NOT )r -a ar ar al of.the violatiori'y, Ci',r ; a or State VICINITY MAP SCALE: NTS SATELLITE VIEW SCALE: NTS PHOTOVOLTAIC SYSTEM SUMMARY SYSTEM SIZE: DC STC: 3.64 KW SYSTEM SIZE: AC CEC 3.14 KW SOLAR MODULES: (14) HYUNDAI HiS-S MICRO INVERTERS: (14) M215-60-21-L-81 MOUNTING SYSTEM: IRONRIDGE ROO ELECTRICAL INFORMATION: MAIN SERVICE PANEL BUS SIZE: 125A MAIN SERVICE BREAKER SIZE: 100A, BUILDING INFORMATION: 6 % TWO STORY HOUSE c� D CONSTRUCTION TYPE: V-B OCCUPANCY: R ROOF: ASPHALT SHINGLE TRUSSES: 2"X4" @ 24" O.C. (BK) PHOTOVOLTAIC ARRAY (14) Hyundai 260 W Solar Modules (HiS-S260 RG (BK)) (14) Enphase Energy (M215-60-2LL-S22-IG) UNIT INDEX MSP (E) 125A Main Service Panel SP (N) 100A Sub Panel J/B (N) Junction Box M215 Micro Inverter Solar Module EMT Type Conduit B.O.S. LOCATION MAP min 4'" o O (N)Sub Panel (E)Main Service Panel South Side view 4 M2 Solar Array 2 10 Hyundai 260W 10 M215 Micro -Inverters Pitch: 37 Deg 7 fire setback j/ 4=�0 �../ Almaden Ave FROM JUNCTION BOX TO ROOF EAVE EMT TYPE CONDUIT WILL RUN OVER THE ROOF AT 1 1/2" HEIGHT, THEN UNDER THE EAVE TO PV EQUIPMENT (CD CUPERTINO Budding Department REVIEWED FOR CODE COMPLIANCE Reviewed By: N 0° W E 270° 90° s 180° SCALE 0 1 5 loft General Notes ROOF PLAN Drawn By: David D. No. Revision/Issue Date CONTRACTOR West Coast Solar Address: 2155 Elkins Way, Suite F Brentwood, CA 94513 Phone Number: 925-516-3900 Lic# 908549 WEST COAST ILI R Joan Thompson Dyer 21835 Almaden Ave, Cupertino, CA 95014 oa. Apr 13, 2016 s.r SWIM AS INDICATED PV SYSTEM NOTE: A continuity of equipment grounding shall be provided with a minimum of #6 AWG copper grounding conductor between rail interconnection, and rail end connection #6 AWG EGC COPPER WIRE PV ARRAY 2 10 HYUNDAI 260 WATT MODULES, 10 ENPHASE M215 MICROINVERTERS PV ARRAY 1 4 HYUNDAI 260 WATT MODULES, 4 ENPHASE M215 MICROINVERTERS PV ARRAY INFORMATION 14 HYUNDAI 260WATT SOLAR MODULES MODEL # HiS-S260 RG (BK) 14 ENPHASE ENERGY MICROINVERTERS MODEL # M215-60-2LL-S22-IG NUMBER OF BRANCH CIRCUITS: 1 NUMBER OF MODULES IN BRANCH CIRCUIT: 14 WATTS STC: 14 * 260W = 3640W MAX AC VOLTAGE: 120/240V PV MODULE RATINGS # STC SHORT CIRCUIT CURRENT I -SC = 8.90A MAXIMUM POWER CURRENT I -MP = 8.40A OPEN CIRCUIT VOLTAGE V-OC = 37.9V MAXIMUM POWER VOLTAGE V-MP = 31.1V INVERTER RATING PEAK PWR TRACKING VOLTAGE = 27-39 V CEC EFFICIENCY = 96.5 % ENCLOSURE: NEMA6 MAXIMUM INPUT CURRENT = 10 A MAXIMUM OUTPUT CURRENT = 0.9 A MAXIMUM INPUT POWER = 210 - 300 W MAXIMUM OUTPUT POWER = 215 W AA J BOX2 NEMA 3R 120 ;FEET J BOX1 NEMA 3R All the photovoltaic systems wires that on the roof and side of the building shall be protected against physical damage ENPHASE ENVOY-S BREAKER INSTALL 2P 20A CB(PV) AT OPPOSITE END OF BUS FROM MAIN FEEDER CB (3)#8 AWG THWN-2 15A 15A 3/4" EMT CONDUIT NEW 100A SUB PANE 10 FEET 120/240V NEMA 3R [ ACA ] FROM PV MODULES TO J-BOX (3) ENPHASE TRUNK CABLE #12 AWG, PV WIRE + (1) #6 AWG BARE CU EGC FREE IN THE AIR [ AC.2 ] FROM J-BOX2 TO J-BOX1,FROM J-BOX1 TO SUB PANEL (3) #10 AWG THWN-2 + (1) #8 AWG CU EGC, 3/4" EMT TYPE CONDUIT, 30 FEET # OF MICROINVERTERS IN BRANCH CIRCUIT: 14 EACH INVERTER OUTPUT MAX CURRENT: 0.9 A BRANCH CIRCUIT CURRENT: 14 * 0.9 *1.25 = 15.8 A BREAKER SIZE PER B. CRCT - 20A MAXIMUM CONTINUOUS CURRENT: 15.8 A RACEWAY HEIGHT FROM ROOF 1 z' (TEMP - 39 + 22 = 61 C) TEMP. DERATE FACTOR - 15.8 A / 0.58 = 27.2 A WIRE SIZE FROM NEC TABLE 310.15(b)16 - 10 AWG AMBIENT TEM FACTOR 0.58 PER NEC 310.15(b)(2)(a) UTILITY M 0 100A TOP FEED 40A U) Z) m (1)#8 AWG GROUND < N EXISTING 125A MAIN SERVICE PANEL 120/240V,1 P,3W, L OVERHEAD #3 AWG EXISTING BUILDING GROUND SYSTEM TO CW PIPE AND'UFER' /' Connection to the Interior metal water piping shall be made within 5 feet from the point of entrance. 250.68(C) (1) CUPERTINO r,y� NY!(r..K r�; Building Department PP1D201S 0 i. REVIEWED FOR CODE COMPLIANCE Reviewed By; ✓� MAIN PANEL RATING SPLIT PHASE: 3W, 120/240V BUSBAR RATING = 125A MAIN SERVICE BREAKER = 100A TOP FEED 120% RULE: MAX ALLOWED FEED: 150A ACTUAL FEED: 100 WSP" + 20 A "SOLAR" = 120 A <= 150A MAX OUTPUT CALCULATIONS PV SYSTEM MAX DC OUTPUT: 14 * 260W = 3640W PV SYSTEM MAX AC OUTPUT: (14) HiS-S260 RG (BK) (14) M215-60-2LL-S22-IG Pmax (PTC Rating) PER MODULE: 232.8W 232.8W * 14 = 3.23 KW 3.23 KW * 96.5% CEC INVERTER = 3.14KW General Notes SINGLE LINE DIAGRAM Drawn By: David D. No. Revision/Issue Date CONTRACTOR West Coast Solar Address: 2155 Elkins Way, Suite F Brentwood, CA 94513 Phone Number: 925-516-3900 Lic# 908549 sit 1. WEST ES T COAST � INC Joan Thompson Dyer 21835 Almaden Ave, Cupertino, CA 95014 Dot. Apr 13, 2016 s.r 2 sm1. AS INDICATED PV SYSTEM (STICKER TO BE LOCATED ON CONDUIT WITH DC CURRENT EVERY 4' HORIZONTALLY OR 10' VERTICALLY AND 1' FROM EACH SIDE OF A BEND) O 0 O O (TO BE LOCATED ON SUB -PANEL ONLY WHEN SUB -PANEL IS DEDICATED FOR PV ONLY) 4 H (STICKER LOCATED INSIDE PANEL NEXT TO SOLAR BREAKER) (STICKER LOCATED INSIDE PANEL BELOW PV BREAKER) (STICKER LOCATED ON THE PV SUB PANEL) Permanent directory or plaque providing location of service disconnecting means and photovoltaic system disconnecting means, if not located at the same location. (Plaques shall be metal or plastic, with engraved or machine printed letters, or electro-photo plating, in a contrasting color to the plaque. Plaques shall be permanently attached to the equipmenq or in the required location using an approved method that is suitable to withstand the environment to which it is exposed. Plaques and signage shall meet legibility, defacemet, exposure and adhesion requirements of Underwriters Laboratories marking and labeling system 969(UL969). Plaques will have red background & white lettering. MARKINGS, LABELS AND WIRING SIGNS A. Purpose: Provide emergency responders with appropriate warning and guidance with respect to isolating solar electric system. This can facilitate identifying energized electrical lines that connect solar panels to the inverter, as these should not be cut when venting for smoke removal B. Main Service Disconnect. 1. Residential buildings - The marking main be placed within the main service disconnect. The marking shall be placed outside cover if the main service disconnect is operable with the service panel closed. 2. Commercial buildings - Tha marking shall be placed adjacent to the main service disconnect clearly visible from the location where the level is operated 3. Markings: Verbiage, Format and Type of Material. a. Verbiage: CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED b. Format: White lettering on a red background. Minimum 3/8 inches letter height. All letters shall be capitalized. Arial or similar font, non bold. c. Material: Reflective, weather resistant material suitable for the environment (use UL - 969 as standard for weather rating). Durable adhesive materials meet this requirement. C.Marking Requirements on DC conduit, raceways, enclosures, cable assemblies, DC combiners and junction boxes: 1. Markings: Verbiage, Format and Type of Material. a. Placement : Markings shall be placed every 10 feet on all interior and exterior DC conduits, raceways, enclosures, and cable assemblies, at turns, above and for below penetrations, all DC combiners and junction boxes b. Verbiage: CAUTION: SOLAR CIRCUIT Note: The format and type of material shall adhere to ' V. V-3b, c" of this requirement. c. Inverters are not required to have caution markings 1.Marking is required on all interior and exterior DC conduit raceways, enclosures,cable assemblies,and junction boxes,combiner boxes and disconnects.CFC 605.11.1 2.The materials used for marking shall be reflective,weather resistant material suitable for the environment. Minimum 3/8 "letter height; all upper case letters Aria] or similar font; Red background with white lettering. CFC 605.11.1.1 3.Marcking shall contain the words: WARNING: PHOTOVOLTAIC POWER SOURCE. CFC 605.11.1.2 4.Marcking shall be placed adjacent to the main service disconnect in a location clearly visible from the location where the disconnect is operated CFC 605.11.1.3 SOLAR PV ARRAY WITH INVERTER TYPE: MICRO s„J`1J t CAUT10-wain,. ;.� iilildil geAarnl r, POWER TO THIS BUILDING IS ALSO SUPPLIED 3 FROM THE FOLLOWING SOURCES'WtTN— E f PV EQUIPMENT LOCATED AS �tIEV�EWED FOR CODE Cov Reviewed By:� O Almaden Ave SOLAR PV ARRAY WITH General Notes e CODE REQUIRED SIGNAGE Drawn By: David D. No. Revision/Issue Date CONTRACTOR West Coast Solar Address: 2155 Elkins Way, Suite F Brentwood, CA 94513 Phone Number: 925-516-3900 Lic# 908549 �nt WEST COAST '�' INC, Joan Thompson Dyer 21835 Almaden Ave, Cupertino, CA 95014 Dd. Apr 13, 2016 Sh a 3 Smh AS INDICATED PrOwt PV SYSTEM FLASH MOUNTING DETAIL MODULE WEIGHT (Ibs) 37.9 # OF MODULES 14 TOTAL MODULE WEIGHT (Ibs) 530 RACK WEIGHT (Ibs) 106 MICROINVERTERS WEIGHT (Ibs) 48 TOTAL SYSTEM WEIGHT (Ibs) 684 # OF STANDOFFS 32 MAX SPAN BETWEEN STANDOFFS (in) 48 LOADING PER STANDOFF (Ibs) 21.4 TOTAL AREA (sgft) 252 LOADING (PSF) 2.71 Dking Brace ATTACHMENT DETAILS 1. Ironridge Racking System 2. Ironridge Flash Foot Attachment 3. Racking loading calculations were performed for ASCE 7-10 wind speeds @ 110 mph for B and C exposure categories and ASCE 7-10 Seismic Design Category E. 4. Roof attachment hardware to be mounted to existing structure (2"x4"@24" O.C. Trusses) at 48" O.C. rail spans or less. 5. Lag bolts are 5/16" X 3.5" stainless steel with 2.5" minimum embedment into the roof rafters. 6. Roof sheathed with 1/2" plywood and upper surface is faced with felt paper. Finished roof surface is Asphalt Shingle. 7. Mounts or/and mounting hardware will be sealed with Tremco Vulkem 116 Polyurethane Sealant or equivalent. IRONRIDGE FLASH FOOT ATTACHMENT IRONRIDGE ROOF MOUNT XR10 RAIL — — — — — — — — — — — EXISTING 2" BY 4", 24 O.C. ROOF TRUSSES CUPERTINO Building Department =D FOR CODE COMPLIi viewed BY: General Notes ATTACHMENT LAYOUT Drawn By: David D. No. Revision/Issue Date CONTRACTOR n-N.h, West Coast Solar Address: 2155 Elkins Way, Suite F Brentwood, CA 94513 Phone Number: 925-516-3900 Lic# 908549 WEST COAST @ 00 L 2% IYC. IgCE Joan Thompson Dyer 21835 Almaden Ave, Cupertino, CA 95014 0eh Apr 13, 2016 err seer AS INDICATED PV SYSTEM 3.64 KW DC (STC) 14 HYUNDAI HiS-S260 RG (BK) 260W MODULES & ENPHASE ENERGY M215-60-2LL-S22-IG MICRO INVERTERS ENVOY SERIAL #: ENVOY LOCATION: C U PEE RT I t COMMUNICATION LEVEL: 1 Building Depar-;Ll ETHERNET BRIDGE INSTALLED: 1041611111:&1 LP -1 ?) Reviewed By: General Notes INVERTER MAP Drawn By: David D. No. Revision/issue Date CONTRACTOR Fb� H— A, A* — West Coast Solar Address: 2155 Elkins Way, Suite F Brentwood, CA 94513 Phone Number: 925-516-3900 Lic# 908549 WEST COAST cin t �11PLIANCF Joan Thompson Dyer 21835 Almaden Ave, Cupertino, CA 95014 od. Apr 13, 2016 Sh.A SmN S INDICATED A -5 ftw PV SYSTEM 3.64 KW DC (STC) 14 HYUNDAI HiS-S260 RG (BK) 260W MODULES & ENPHASE ENERGY M215-60-2LL-S22-IG MICRO INVERTERS CUPERTINO k.y n�k' Building Department REVIEWED FOR CODE COMPUA Reviewed By: 9�" %T General Notes MODULE MAP Drawn By: David D. No. Revision/Issue Date CONTRACTOR West Coast Solar Address: 2155 Elkins Way, Suite F Brentwood, CA 94513 Phone Number: 925-516-3900 Lic# 908549 W. �_.. WEST COAST L -' PR NYC Joan Thompson Dyer 21835 Almaden Ave, Cupertino, CA 95014 Dal. Apr 13, 2016 s.w 6 smh AS INDICATED AvI t PV SYSTEM Enphase`1 M215 Microinverter // DATA Enphase'y Microinverters INPUT DATA (DC) M215-60-2LL-S22-IG, M215-60-2LL-S25-IG Recommended input power (STC) 190 - 270 W EnphaseeM215 Maximum input DC voltage 48 V Peak power tracking voltage 27 V - 39 V Operating range 16 V - 48 V Min/Max start voltage 22 V / 48 V Max DC short circuit current 15 A OUTPUT DATA (AC) @208 VAC @240 VAC Peak output power 225 W 225 W E P Rated (continuous) output power 215 W 215 W MOE Nominal output current 1.03 A (A rms at nominal duration) 0.9 A (Arms at nominal duration) Nominal voltage/range 208 V / 183-229 V 240 V / 211-264 V Nominal frequency/range 60.0 ! 57-61 Hz 60.0./ 57-61 Hz r , Extended frequency range 57-62.5 Hz 57-62.5 Hz The Enphase' M215 Microinverl;er with integrated ground delivers increased energy harvest and reduces design and installation complexity with its all -AC approach. With the advanced M215, the DC circuit is isolated and insulated from ground, so no Ground Electrode Conductor (GEC) is required for the microinverter. This further simplifies installation, enhances safety, and saves on labor and materials costs. The Enphase M215 integrates seamlessly with the Engager Cable, the Envoy' Communications Gateway', and Enlighten', Enphase's monitoring and analysis software. Power factor >0.95 >0.95 Maximum units per 20 A branch circuit 25 (three phase) 17 (single phase) Maximum output fault current 850 mA rms for 6 cycles 850 rnA rms for 6'cycles EFFICIENCY CEC weighted efficiency, 240 VAC 96.5% CEO weighted efficiency, 208 VAC 96.5% Peak inverter efficiency 96.5°% Static MPPT efficiency (weighted, reference EN50530) 99.4 % Night time power consumption 65 mW max MECHANICAL DATA Ambient temperature range Dimensions (WxHxD) Weight Cooling Enclosure environmental rating Connector type FEATURES Compatibility Communication -40°C to +651C 171 mm x 173 mm x 30 mm (without mounting bracket) 1.6 kg (3.4lbs) Natural convection - No fans Outdoor - NEMA 6 M215-60-2LL-S22-IG: MC4 M215-60-2LL-S25-IG: Amph of H4 Compatible with 60-cell PV modules. Power line CL Sui1d PRODUCTIVE SIMPLE RELIABLE tip?; Integrated ground The DC circuit meets the requirements for ungrounded Panaysfm,; Maximizes energy production - No GEC needed for microinverter More than 1 million hours of testing 'Cable No•�m'� NEC 690.35. Equipment ground is provided in the Engagadditional GEC or ground is required. Ground fault protection (GFP) is - Minimizes impact of shading, - No DC design or string calculation and millions of units shipped integrated into the microinverter. REVIEWED r Q IT dust, and debris required Industry -leading warranty, tlp to 25 Monitoring Enlighten Manager and MyEnlighten monitoring options No single point of system failure - Easy installation with Engage years {� Compliance UL1741/IEEE1547, FCC Part 15 Class B, CAN/CSA-C22.2 NO. 0-M91RGVieWed Cable 0.4-04, and 107.1-01 Frequency ranges can be extended beyond nominal if required by the utility [] elnphase- Sla® To learn more about Enphase Microinverter technology, [ i enphasee � E N E R G Y C US visit enphase.com E N E R G Y 02015 Enphase Energy. All rights reserved. All tradamarks or brands in iris document are registered by their respective owner. MKT M69 Rev 1.0 General Notes INVERTER DATA SHEET Drawn By: David D. No. Revision/Issue Date CONTRACTOR West Coast Solar Address: 2155 Elkins Way, Suite F Brentwood, CA 94513 Phone Number: 925-516-3900 Lic# 908549 WEST COAST j t INC Department it n 1^ I .1 0II CODE COfy PLI N(D'E na}d Icy,. • ,� Joan Thompson Dyer 21835 Almaden Ave, Cupertino, CA 95014 ow Apr 13, 2016 a.A 7 ScaN AS INDICATED �r PV SYSTEM m"Oilhi-green.com/solar L".i`•'_<i:S1 Multi -crystalline Type � Hyundai Heavy Industries was founded in 1972 and is a Fortune 500 company. The company employs more than 48,000 people, and has a global leading 7 business divisions with sales of 60.2 Billion USD in 2012. As one of our core businesses of the company, Hyundai Heavy Industries is committed to develop and invest heavily in the field of renewable energy. Hyundai Solar is the largest and the longest standing PV cell and module manufacturer in South Korea. We have 600 MW of module production capacity and provide high -quality solar PV products to more than 3,000 customers worldwide. We strive to achieve one of the most efficient PV modules by establishing an R&D laboratory and investing more than 20 Million USD on innovative technologies. Multi -crystalline Type HIS-M250RG I HiS-rA255RG 1 HiS-M260RG RG®Series Mono -crystal line Type HiS-S260RG I HiS-5265RG I HiS-S270RG e (1i,i-eC.50;`iiC:; l..lha#%:ti.w'=.''kFiti.r 998 nim (39.29")(W) x 1,640 mm (64.57")(L) x 35 mm (1.38")(H) Approx. 17.2 kg (37.9lbs) 60 cells in series (6 x10 matrix) (Hyundai cell, Made in Korea) 4 mm' (12AWG) cables with polarized weatherproof connectors, IEC certified (UL listed), Length 1.0 m (39.4) IP68, weatherproof, IEC certified (UL listed) 3 bypass diodes to prevent power decrease by partial shade Front: High transmission low -iron tempered glass, 2.8 mm (0.11") Encapsulant:EVA Back Sheet: Weatherproof film Clear anodized aluminum alloy type 6063 s IEC 61215 (Ed.2) and IEC 61730 by VIDE UL listed (UL 1703), Class C Fire Rating • Output power tolerance +3/-0 % ISO 9001:2000 and ISO 14001:2004 Certified Advanced Mechenical Test (5,400 Pa) Passed (IEC) / Mechanical Load Test (40lbs/ft7) Passed (LIQ Ammonia Corrosion Resistance Test Passed • IEC 61701 (Salt Mist Corrosion Test) Passed e?(.d�r;3''S :-"i' ,' iNlour i�9 Delivered ready for connection IEC (LIQ certified and weatherproof connectors Integrated bypass diodes LIi-:�i=�1 )"i1/L!q"M r'i63:P 10 years for product defect 10 years for 90 % of warranted min, power 25 years for 80 % of warranted min. power A Important Notice on Warranty TnewarranDe:applvonlyto'her^:'mcdulesv:itillyundai Ieavyinocsrl.SCG__td:s logo (shown bet ,v) and PT -,duct serial nurrber cn it. Ptrcrc� 6 Lima (cg s HYU N DAI HEAVY INDUSTRIES CO.,LTD. Nominal output (Pmpp) Voltage at Pmax (Vmpp) Current at Pmax (Impp) Open circuit voltage (Voc) Short circuit current (Isc) Output tolerance No. of cells & connections Cell type Module efficiency j Temperature coefficient of Pmpp I Temperature coefficient ofVoc j Temperature coefficient of Isc W 250 255 260 V 30.9 31.0 31.1 A 8.1 8.2 8.4 V 37.4 37.6 37.7 A 8.7 8.8 8.9 Q'6 +3/-0 PCs 60 In series 6" Multi -crystalline silicon (Hyundai cell, Made in Korea) °.v 15.3 15.6 15.9 %/K -0.43 .0.43 -0.43 46/K -0.32 -0.32 -0.32 461K 0,048 0.048 0.048 3T All datJ al S I(_ 616ridaid Iet L::,IdI11Ul'i). AI;UV(' 1j : If,; I,, t11,i(jed :Yitl"UUl rtllUl nut; c. I Mono -crystalline Type I t t' �W Nominal output (Pmpp) 260 265 270 Voltageatpmax(Vriipp) tti V 1 31.1 31.3 31A Current at Pmax (Impp) A 8.4 8.5 8.6 Open circuit voltage (Voc) V 37.9 38.1 38.2 Short circuit current (Isc) A 8.9 9.0 9.2 Outputtolerance I % +3i-0 No. of cells & connections 1 PCs 60 in series Ceti type 6"Mono-crysta[line silicon (Hyundai cell, Made in Korea) Module efficiency % 15.9 162 16.5 Temperature coefficient of Pmpp %/K -0.45 -0.45 -0.45 Temperature coefficient of Voc %/K -0.33 -0.33 -0.33 Temperature coefficient of Isc 0,'9/K 0.032 0.032 0.032 X ;II dal a at Sir (tit: •i,bid I s1('cndit`.nr;i A;:nve dF-n may F.e rhanr11',vilhnn1 I Module Diagram I (unit: Min, inch) I I-V Curves I C-It IAI a B 1,000YJlrn' _ iSc , \ a +x atin 75(03') y -6SC 0 HORS tl (I} DETAILA 39S'; 0537I bfllSLOTTKYI, 4m 166!F& 4nm'CARLS E(0.3.1 CDNYcCTOR CaNNKTOR d u �' CurteniW Voka9e lh .GROUNDMAW. $ DETAILB Id At V) -� -13Y, inr GRDUNDF.OIE b'h V,m r fiO Pam'' � 630V 951137561 v Li C-'Y s< (( �iC 2534^961 U%' yi`i�,'` Gd Ll l I` 11 SECTIONOC t Installation Safety Guide 46C±2 Only qualified personnel should install or perform maintenance. �Cn,.,- f ,, ( =_ -REVIEWED F O R Be aware of dangerous high DC voltage. „J~ tt , - DC 1,000 V (IEC) Do not damage or scratch the rear surface of the module. L -- ' DC600V (Ut), Reviewed E Do not handle or install modules when they are we -' h €k' - 15 A t Sales & Marketing 2" FL, Hyundai Bldg., 75, YulgokoJonyno-gu, Seoul 110-793, Korea HYU N DAI rise Tel: +82-2-74s-sao6,74zz,6525 Fax:+A2-2-746-7675 HEAVY INDUSTRIESCo.,LTD. General Notes MODULE DATA SHEET Drawn By: David D. No. Revision/Issue Date CONTRACTOR meN_ aAa- West Coast Solar Address: 2155 Elkins Way, Suite F Brentwood, CA 94513 Phone Number: 925-516-3900 Lic# 908549 WEST COAST R:INO )cparment . DE COtlilPUANC.E Hord 11a. a/`1 Joan Thompson Dyer 21835 Almaden Ave, Cupertino, CA 95014 Wt. Apr 13, 2016 s d 8 S.I. AS INDICATED Aord PV SYSTEM CERTIFICATE OF COMPLIANCE Certificate Number 20150331-E325005 Report Reference E325005-20110831 Issue Date 2015-MARCH-31 j Issued to: HYUNDAI HEAVY INDUSTRIES CO LTD 1-5 DAEJANG-RI SOI-MYEON EUMSEONG-GUN CHUNGCHEONGBUK-DO 369-872 KOREA This is to certify that PHOTOVOLTAIC MODULES AND PANELS representative samples of "HiS-SxxxMF, HiS-MxxxMF, HiS-SxxxMG and HiS-MxxxMG Series with specific construction described in installation instructions compliant to Photovoltaic Module Fire Performance Type 1" 111 Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s) for safety: The fire test method was in accordance to "Standard For Safety For Flat -Plate Photovoltaic Modules and Panels", UL 1703, 3rd Edition, dated December 18, 2014. ULC 0RD/C1703-01 "Flat -Plate Photovoltaic Modules and Panels", 1 Additional Information: See the UL Online Certifications Directory at www.u1.com/database for additional information Only those products bearing the UL Certification Mark should be considered as being covered by UL's Certification and Follow -Up Service. Look for the UL Certification Mark on the product' l F`''y'";'''r"'°•'`� Building Dep REVIEWED FOP. COD Reviewed By. ':' Bmce %bhmnhot:, Assistant Char Engineer, alabat Inspection and Field Servicas UL LLC Any Information and dmunettlat'mn involving UL Nark services am provided on behalf of UL LLC JUL) of any authariwd licensee or UL For questions, please Contact a local UL Cost- Service Rep -at,, live aty W W.ul.Com'contaGius Page 1 of 1 General Notes MODULE CERTIFICATION Drawn By: David D. No. Revision/Issue Date CONTRACTOR rim Re n. a aa— West Coast Solar Address: 2155 Elkins Way, Suite F Brentwood, CA 94513 Phone Number: 925-516-3900 Lic# 908549 WEST COAST 11C '10 L-nent OMPLIANCE AaJrC tar.. • aen. Joan Thompson Dyer 21835 Almaden Ave, Cupertino, CA 95014 Dow Apr 13, 2016 0.4 9 Sovh AS INDICATED r'A)Al PV SYSTEM IRONRIDGE Staijt for solar'' toughest roofs Roof Mount System IronRidge builds the strongest roof mounting system in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced (lashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. i Strength Tested I All components evaluated for superior structural performance. Class A Fire Rating Certified to maintain the fire resistance rating of the existing roof. PE Certified Pre -stamped engineering letters LC available in most states. Design Software Online tool generates a complete bill of LL materials in minutes. f j Integrated Grounding 20 Year Warranty fI UL 2703 system eliminates separate/ Twice the protection offered by module grounding components. competitors. )\IR R,aiIS XR10 Rail A low -profile mounting rail for regions with light snow. • 6' spanning capability • Moderate load capability • Clear anodized finish FlashFoot XR100 Rail XR1000 Rail Internal Splices e The ultimate residential A heavyweight mounting All rails use internal splices solar mounting rail. rail for commercial projects. for seamless connections. • 8'spanning capability 12'spanning capability Self -tapping screws • Heavy load capability Extreme load capability Varying versions for rails • Clear & black anod. finish Clear anodized finish Grounding Straps offered Slotted L-Feet Standoffs Tilt Legs AERMI Anchor, flash, and mount Drop -in design for rapid rail Raise flush or tilted Tilt assembly to desired with all -in -one attachments. attachment. systems to various heights. angle, up to 45 degrees. Ships with all hardware High -friction serrated face Works with vent flashing Attaches directly to rail • IBC & IRC compliant Heavy-duty profile shape Ships pre -assembled Ships with all hardware • Certified with XR Rails Clear & black anod. finish Lengths from 3" to 9" Fixed and adjustable Clangs Q't Grounding End Clamps Grounding Mid Clamps Ct!:-) T Bolt Grounding^ Lugs (5- Accessories "ta s I Slide in clamps and secure Attach and ground modules Ground system using the Provide a finished and modules at ends of rails. in the middle of the rail. rail's top slot. organized look for rails. r,.sr.,..- • Mill finish & black anod. Parallel bonding T-bolt Easy top -slot mounting Snap -in Wir°hGl ps w_ _ i % L ( i • Sizes from 1.22" to 2.3" Reusable up to 10 times Eliminates pre -drilling Perfected d Caps l_a Build • Optional Under Clamps Mill & black stainless Swivels in any direction UV -protects polymer ` l Free Resources Design Assistant A NABCEP Certified Trainini, EVIEVVEJ r Q Go from rough layout to fully 17 y' Earn free continuing education credit ! engineered system. For tree. ^� m while learning more about our systemeVeWed Go to ironRicl9e.co,n/rnt � 7 � Go to Iron Ridgaxom/'training sryr,, z; 4 General Notes RACKING DATA SHEET Drawn By: David D. No. Revision/Issue Dote CONTRACTOR West Coast Solar Address: 2155 Elkins Way, Suite F Brentwood, CA 94513 Phone Number: 925-516-3900 Lic# 908549 WEST COAST ir+c = ERTINO g Department 3 2016 -•ODE COMPLIANCE Joan Thompson Dyer 21835 Almaden Ave, Cupertino, CA 95014 ocrt. Apr 13, 2016 s.r S.I. AS INDICATED 10 nala PV SYSTEM 8431 Murphy Drive Middleton, WI 53562 USA Telephone: 608.836.440 0 Facsimile: 608.831.9279 www.intertek.com kl \(,,8;,.sn !J e Hfi ca fl o o It O ti r r i!' 1 ey� In the basis of the tests undertaken, the sample(s) of the below product have been found to comply with the requirements of the referenced specifications at the time the tests were carried out. (Applicant Name & Address: Product Description: Ratings_& Principle Characteristics: Iron Ridge; Inc. 1495 Zephyr Ave. Hayward, CA 94544 USA XR Rails with Integrated Grounding. Fire Class Resistance Rating: -Flush Mount (Symmetrical). Class A Fire Rated for Low Slope applications when using Type 1, 2 and 3, listed photovoltaic modules. Class A Fire Rated for Steep Slope applications with Type1, 2 and 31 listed photovoltaic modules. Tested with a 5" gap (distance between the bottom the module frameand the roof covering),, per the standard this system can be installed at any gap allowed by the manufacturers installation instructions. No perimeter guarding is required. Models: 151-616D-005, 51-61GD-005B, 51-5000-001 and 517-65-001 Brand Name: Relevant Standards: Verification Issuing Office: Date of Tests: Test Report Nu IronRidge Roof .Mount UL 2703 (Section 15.2 and 15.3) Standard for Safety Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use.with Flat -Plate Photovoltaic Modules and Panels, First Edition dated Jan. 28, 2015 Referencing UL1703 Third Edition dated Nov. 18, 2014, (Section 31.2) Standard for Safety for Flat -Plate Photovoltaic Modules and Panels. Intertek Testing Services NA, Inc. 8431 Murphy Drive Middleton, WI 53562 08/27/2014to 03/17/2015 101769343MID-001r1, 101769343MID-001a, 101915978MID-001 & 101999492MID-001ar1-cr1. This verification is part of the full'test report(s) and should be read in conjunction with them. This report does not automatically imply product certification. Completed by: Chad Naggs Reviewed by: " Gregory Allen Title: Technician II, Fire Resistance Title: Engineering Team Lead, Fire Resistance r �� ��r! Signature: Signature: µ_ Date: 03/30/2015 Date: 03/30/2015 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek, and its Client. intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek ossumes no liability to any party, other than to the Client in accordance with the agreement, for an}, loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one ofits marks for the sale or advertisement of the tested material, product or service .must first be approved in writing by Intertek. The observations and test inspection results referenced in this Verification are relevant only to the sample tested/inspected. rhis Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. GIFT-OP-11a (24-MAR-2014) CUPERTlh FJUiiuln; [[jj1i !Depanr y" REVIEWED FOR CODE C( Reviewed By: General Notes RACKING CERTIFICATION Drawn By: David D. No. Revision/Issue Date CONTRACTOR Am N— & .&— West Coast Solar Address: 2155 Elkins Way, Suite F Brentwood, CA 94513 Phone Number: 925-516-3900 Lic# 908549 WEST COAST r""V r LL [FRD IO (lent I MC' LIANCE Joan Thompson Dyer 21835 Almaden Ave, Cupertino, CA 95014 Der Apr 13, 2016 a.w SwN AS INDICATED PV SYSTEM 0 r IRONRIDGE Rapid & Secure Solar Arta hrnents IronRidge FlashFootTM is an all -in -one solar mounting product for composition shingle roofs that eliminates the need for separate standoffs, (lashings, and L-feet. FlashFoot incorporates a number of structural and waterproofing features to securely attach IronRidge Rails to roof structures, while also protecting against water intrusion and weather damage. 0.050, Load Distribution Plate A solid metal plate below the L-toot t increases the FlashFoot's structural strength and prevents any deformation of the flashing during installation. Cedlfled compliant 1gPM0 nigh IBC end IRC. EB 4 FlashFoot"I Dual Mechanical Seal At the core of the FlashFoot, a pre -installed rubber bushing forms a dual mechanical seal, with its exterior compressed against the cavity of the L-foot and its interior tightly wrapping around the shaft of the lag bolt. Water Shedding Design A wide flashing layer combined with an elevated sealing platform maximizes the FlashFoot's water shedding ability. Installation Overview Tools Required: tape measure, chalk line, stud finder, roofing bar, caulking gun with an approved sealant, drill with 1/4" bit and 1/2" socket. Locate rafters and snap vertical and horizontal lines to mark locations of flashings. Drill 1/4" pilot holes, then backfill with an approved sealant. Line up pilot hole with flashing hole and insert lag bolt through bonded washer, L-Foot, and flashing. Tighten lag bolt until fully seated. Testing & Certification Slide flashing, between 1st and 2nd course, so the top is at least 3/4" above the edge of the 3rd course and the bottom is above the edge of the 1 st course. The FlashFoot is now installed and ready for IronRidge Rails. With provided L-foot fasteners pre - loaded into rails, drop rails into open L-foot slots. FlashFoot is certified for compliance with the International Building Codes (IBC) & International Residential Codes (IRC) by IAPMO-ES. Mechanical testing conformed to the standard for Testing and Analysis of Joist Hangers and Miscellaneous Connectors (EC002-2011), and rain testing conformed to the Und r to ��y �� Laboratory Standard for Gas Vents (UL441-96 Section 25).'<<�: ><' i Building De I Dwgl. Fir. Lard, _..s-.....®_...._.-._..� 5Z I Douglas Rr, Scull, .4ri I i 5x,jeimwv, Syr !,,e, LudgepuM: Rnu {MSR 16501 d higher) .46 7705 Hem. Fir ( .43 `/�' I REV I E V Y E 1 Hem. Fir (NctlII _ - - _ .ds 705 i Soulhem Pine .55 021 Rev e Spruce. Pine, Fir .42 I 615 Spruce. Pine. Fir (E o12 million psi and higher grades of MSR and MEQ t .50 750 . _ � .._._._®� �T� 41['�_--��",��r,?�f py'°Y,i�cY l��ist"w.1`+��:>'G_aru'1; �1'tt-� �% _'�'h.; L•,�i..l�. �s e._1[' S',r'u1,51 �...,.-_�._..�.. �y%/ r�P -OR CO red By: General Notes ATTACHMENT DATA SHEET Drawn By: David D. No. Revision/Issue Date CONTRACTOR rn. %— •ran. West Coast Solar Address: 2155 Elkins Way, Suite F Brentwood, CA 94513 Phone Number: 925-516-3900 Lic# 908549 WEST COAST " tuc tment COMPLIANCE Joan Thompson Dyer 21835 Almaden Ave, Cupertino, CA 95014 D1W Apr 13, 2016 NAM 12 S.I. AS INDICATED Aopol PV SYSTEM CUP RTINt .dclr%s— PURPOSE SMOKE I CARBON MONOXIDE ALARMS OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE CUPERTINO, CA 95014-3255 (408) 777-3228 . FAX (408) 777-3333 • building(a.cupertino.org This affidavit is a self -certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R314, 2013 CBC Sections 420.6 and 907.2.11.2 where no interior access .for inspections are required. GENERAL INFORMATION Existing single-family and multi -family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds $1000.00, CRC Section R314 and CBC Sections 9072.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations: AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of the bedroom(s) X X On every level of a dwelling unit including basements X X Within each sleeping room X Carbon Monoxide alarms are not required in dwellings which do not contain fuel -burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. Power Supply: In dwelling units with no commercial power supply, alarm(s) may be solely battery operated. In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl space. Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2. An electrical permit is required for alarms which must be connected to the building wiring. As owner of the above -referenced property,, I hereby certify that the alarm(s) referenced above has/have been installed in accordance with the manufacturer's instructions and in compliance with the California,Building and California Residential, Codes. The alarms have been tested and are operational,, as of the datel sighed below. t have read and agree, to comply with the terms and conditions of this statement ................... `. bat ". . Sinafuse—� ......._.. ......... ...._.... ......... ..... Lra�.......................................a-fe , "=�­ L F i " WATER -CONSERVING PLUMBING FIXTURES f OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION CUPERTINO I I0300 TORRE AVENUE ® CUPERTINO, CA 95014-3255 408) 777-3228 • FAX (408) 777-3333 building(a)cuQertino.ora yy Owner Name' i 4 Permit No,'iBaD 6— I Address' v 1. Is your real property a registered historical site? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. t ZNo Go to Question 2. 2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its plumbing, installation of water -conserving plumbing fixtures is not technically_ feasible? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply: ❑ The licensed plumber's certification has been provided to the Building Division. Skip the rest of the form and sign bottom of farm. 0 L;�-No Go to Question 3. 3. Is water service permanently disconnected for your building? . ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. kO-No Go to Question 4. 4. Is your real property built and available for use or occupancy on or before January 1, 1994? No My real property is built and available for use or occupancy after January 1, 1994. Civil Code Sections 1101.1 through .1101.8 do not apply. Skip the rest of the form and sign bottom of form. PYes My real property is built and available for use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101.8 apply. Check one of the three following statements and sign bottom of form.. 5. Please check ONE of the following: 91:�My property is a single-family residential real property. See Civil Code Section 1101.4. On and after January 1, 2014, building alterations or improvements shall require all non -compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non- compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements). D My property is a multifamily residential real property. See Civil Code Section 1101.5.. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non -compliant plumbing fixtures shall be replaced with water - conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). My property is a commercial real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non -compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). I, as the owner or owner's agent of this property, certify under penalty of perjury that non -compliant plumbing fixtures will be replaced prior to date specified above with water -conserving plumbing fixtures in accordance with Civil Code Sections 1101.1 through 1101.8, the current California Plumbing Code and California Green Building Standards Code, and manufacturer's installation requirements, and that the water_conserving plumbing fixtures comply with the requirements as indicated in the table on the following page. Owner or Owner Agent's Signaturei `jam! � .,, A_ Date: I 42 le Upon completing and signing this Certificate, please return it to the Building Division in order to final your building permit. SB40 7 2015. doc revised 08126115