B-2016-1760CITY OF CUPERTINO BUILDING PERMIT
BUILDING ADDRESS: CONTRACTOR: PERMIT NO: B-2016-1760
21835 ALMADEN CIR CUPERTINO, CA 95014-2803 (357 15 088) WEST COAST SOLAR
INC
BRENTWOOD,CA
94513
OWNER'S NAME: DYER BRUCE T TRUSTEE & ET AL DATE ISSUED: 04/13/2016
OWNER'S PHONE: 925-516-3900 PHONE NO: (925) 516-3900
LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO:
License Class C-46, C-39 Lic. #908549
Contractor WEST COAST SOLAR INC Date 12/31/2017 X BLDG X ELECT —PLUMB
I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing MECH X RESIDENTIAL COMMERCIAL
with Section 7000) of Division 3 of the Business & Professions Code and that my
license is in full force and effect. JOB DESCRIPTION:
INSTALL (N) PV SOLAR ARRAY SYSTEM FLUSH -MOUNTED
I hereby affirm under penalty of perjury, one of the following two declarations: DIRECTLY TO THE ROOF - 3.64 KW AND 14 MODULES
n. I have and will maintain a certificate of consent to self -insure for Worker's
Compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
7-0 I have and will maintain Worker's Compensation Insurance, as provided for by
Or Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued. Sq. Ft Floor Area: Valuation: $12000.00
APPLICANT CERTIFICATION
I certify that I have read this application and state that the above
information is correct. I agree to comply with all city and county ordinances
and state laws relating to building construction, and hereby authorize
representatives of this city to enter upon the above mentioned property for
inspection purposes. (We) agree to save indemnify and keep harmless the
City of Cupertino against liabilities, judgments, costs, and expenses which
may accrue against said City in consequence of the granting of this permit.
Additionally, the applicant understands and will comply with all non -point
source regulations per the Cupertino Municipal Code, Section 9.18.
Date 4/13/2016
OWNER -BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for one of the
following two reasons:
n. I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for
sale (Sec.7044, Business & Professions Code)
2. I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project (Sec.7044, Business & Professions Code).
I hereby affirm under penalty of perjury one of the following three declarations:
n. I have and will maintain a Certificate of Consent to self -insure for Worker's
Compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
2. I have and will maintain Worker's Compensation Insurance, as provided for by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued.
3. I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the
Worker's Compensation laws of California. If, after making this certificate of
exemption, I become subject to the Worker's Compensation provisions of the
Labor Code, I trust forthwith comply with such provisions or this permit shall
be deemed revoked.
APPLICANT CERTIFICATION
I certify that I have read this application and state that the above information is
correct. I agree to comply with all city and county ordinances and state laws
relating to building construction, and hereby authorize representatives of this city
to enter upon the above mentioned property for inspection purposes. (We) agree
to save indemnify and keep harmless the City of Cupertino against liabilities,
judgments, costs, and expenses which may accrue against said City in
consequence of the granting of this permit. Additionally, the applicant understands
and will comply with all non -point source regulations per the Cupertino Municipal
Code, Section 9.18.
Signature Date 4/13/2016
APN Number: Occupancy Type:
357 15 088
PERMIT EXPIRES IF WORK IS NOT STARTED
WITHIN 180 DAYS OF PERMIT ISSUANCE OR
180 DAYS FROM LAST CALLED IN ECTION.
Issued by: Alex Valleluneaa:* :: ?
Date: 04/ 13/2016
RE -ROOFS:
All roofs shall be inspected prior to any roofing material being installed. If a roof is
installed without first obtaining an inspection, I agree to remove all new materials for
inspection.
Signature of Applicant:
Date: 4/13/2016
ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER
HAZARDOUS MATERIALS DISCLOSURE
I have read the hazardous materials requirements under Chapter 6.95 of the
California Health & Safety Code, Sections 25505, 25533, and 25534. I will
maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the
Health & Safety Code, Section 25532(a) should I store or handle hazardous
material. Additionally, should I use equipment or devices which emit hazardous
air contaminants as defined by the Bay Area Air Quatity Management District I
will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and
the Health & Safety Code, Sections 25505, 25533, and 25534.
Date: 4/13/2016 6;1� ��
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance
of work's for which this permit is issued (Sec. 3097, Civ C.)
Lender's Name
Lender's Address
ARCHITECT'S DECLARATION
I understand my plans shall be used as public records.
Licensed
Professional
CUPERTINO
CONSTRUCTION PERMIT APPLICATION
COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION
10300 TORRE AVENUE • CUPERTINO, CA 95014-3255
(408) 777-3228 • FAX (408) 777-3333 • buildingc@-cupertino.org
❑ NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION / TI ❑ REVISION / DEFERRED
L)' U - 1--+ 6 U
ORIGINAL PERMIT #
PROJECT ADDRESS
Azdpe-j C/1 r
APN # If_
141t_15
__,6
OWNERNAME 7 PHONE q�� r 3c4 4 E-MAIL
e-t-
STREET ADDRESS
CITY, STATE, ZIP
FAX
Adle
CONTACT NAME O
PHONE-
�_ �i� /�
6
E-1 L f O�/%/� 60/7
STREET ADDRESS .
CITY, STATE, ZIP
S/
FAX
2/ IA)
.c cdOd
SZS - /G - 3 q 3
❑ OWNER ❑ OWNER-BU DER ❑ OWNER AGENT ❑ CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT
CONTRACTOR NAME
LICEN E NUMBER
LICENSE TYPE
BUS. LIC #
sus
� - 3
CO ANY NAME
AICS r- t'o sT oz,44-
E-
&260 & wesrCOAS7-S*4064
44 cow
FAX
39Zj - _5 6 - 3 9.3 S<
STREET ADDRESS
C STATE,
//
PHONE a
K/ /�
.
(J
/ � — � V
ARCHITECT/ENGINEER NAME
LICENSE NUMBER
BUS. LIC #
COMPANY NAME
E-MAIL
FAX
STREET ADDRESS
CITY, STATE, ZIP
PHONE
DESCRIPTION OF WORK
/0'W
OLY
(A) 5k DA OQ Q A
EXISTING USE
PROPOSED USE CONSTR.
TYPE
# STORIES
USE
TYPE
OCC.
SQ.FT.
VALUATION ($)
EXISTG
NEW FLOOR
DEMO
TOTAL
AREA
AREA
AREA
NET AREA
BATHROOM
KITCHEN
OTHER
REMODEL AREA
REMODEL AREA
REMODEL AREA
PORCH AREA
DECK AREA
TOTAL DECK/PORCH AREA
GARAGE AREA: LJDETACH
ATTACH
# DWELLING UNITS:
IS A SECOND UNIT ElYES
SECOND STORY ❑YES
BEING ADDED? []NO
ADDITION? []NO
PRE -APPLICATION ❑ YES IF YES, PROVIDE COPY OF
IS THE BLDG AN ❑ YES
RECEIVED BY:
TOTAL VALUATION:
PLANNING APPL # ❑ NO PLANNING APPROVAL LETTER
EICHLER HOME? ❑ NO
�DC
By my signature below, I certify to each of the following: I am the property owner or authorized agent to At on the p operty owner's behalf. I h ve read this
application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local
ordinances and state laws relating to building construction. I authorize representatives of Cupertino
to enter the above-identifiedpropertyfor inspection purposes.
Signature of Applicant/Agent:
Date:
EN
SUPPLEMT ORMATI QUIRED
PLAN CHECK TYPE ; "
ROUTING SLIP
_ New SFD or Multifamily dwellings: Apply for demolition permit for
❑ ovER THE-coulvTEltu
- -�,q� REVIEW
existing building(s). Demolition permit is required prior to issuance of building
"EXPRESS `
'-
"
09. (RE/
permit for new building.
❑`
PLANNING REVIEW
_ Commercial Bldgs: Provide a completed Hazardous Materials Disclosure
❑. STANDARD ."
❑ PUBLICwORKS
form if any Hazardous Materials are being used as part of this project.
❑ LAtGE
❑ FIRE DEPT
_ Copy of Planning Approval Letter or Meeting with Planning prior to
❑ MAJOR
❑ SANITARY SEWER DISTRICT
submittal of Building Permit application.
❑ ENVIRONMENTAL HEALTH
B1dgApp 2011.doc revised 06121111
GENERAL NOTES
1. ALL ELECTRICAL MATERIALS SHALL BE NEW AND LISTED BY
RECOGNIZED ELECTRICAL TESTING LABORATORY
CUSTOM MADE EQUIPMENT SHALL HAVE COMPLETE TEST DATA
SUBMITTED BY THE MANUFACTURER ATTESTING TO ITS SAFETY
2. OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED
3. ALL METALLIC EQUIPMENT SHALL BE GROUNDED
4. ALL SPECIFIC WIRING IS BASED ON THE USE OF COPPER.
5. CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS PRIOR TO
INSTALLATION AND SHALL COORDINATE ALL INSPECTIONS, TESTING
COMMISSIONING AND ACCEPTANCE WITH THE CLIENT,
UTILITY CO. AND CITY INSPECTORS AS NEEDED.
6. THE ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT
LOCATIONS OF SERVICE POINTS AND SERVICE SIZES WITH THE
SERVING UTILITY COMPANY AND COMPLY WITH ALL UTILITY
COMPANIES REQUIREMENTS. IF THE SOLAR BACK FED BREAKER IS
VOER THE BUSS SIZE 20% LIMIT, CONTRACTOR SHALL INCLUDE THE
COST TO REPLACE MAIN BREAKER OR ENLARGE MAIN CAPACITY.
7. DRAWINGS ARE DIAGRAMMATIC ONLY, ROUTING OF RACEWAYS
SHALL BE OPTION OF THE CONTRACTOR UNLESS OTHERWISE
NOTED AND SHALL BE COORDINATED WITH OTHER TRADES.
8. IF THE ROOF MATERIAL OR ROOF STRUCTURE NOT ADEQUATE
FOR PV INSTALLATION, CALL ENGINEER PRIOR TO INSTALL. THE
CONTRACTOR IS RESPONSIBLE TO VERIFY THAT THE ROOF IS
CAPABLE OF WHITSANDING THE EXTRA WEIGHT.
9. IF THE DISTANCES FOR CABLE RUNS ARE DIFFERENT THAN
SHOWN, THE CONTRACTOR SHALL NOTIFY THE ELECTRICAL
ENGINEER TO VALIDATE THE SIRE SIZE. FINAL DRAWINGS
WILL BE RED -LINED AND UPDATED AS APPRPRIATE.
6. ALL PV MODULES AND ASSOCIATED EQUIPMENT AND
WIRING SHALL BE PROTECTED FROM ANY PHYSICAL
DAMAGE.
7. LIVE PARTS OF PV SOURCE CIRCUITS AND PV OUTPUT
CIRCUITS OVER 150V TO GROUND SHALL NOT BE
ACCESSIBLE TO OTHER THAN QUALIFIED PERSONS WHILE
ENERGIZED.
8. INVERTER IS EQUIPED W/ INTEGRATED GFDI, THUS
PROVIDING GROUND FAULT PROTECTION
9. ALL CONDUCTORS SHALL BE COPPER AND 90 DEG RATED
10. ALL ELECTRICAL EQUIPMENT SHALL BE LISTED BY A
RECOGNIZED ELECTRICAL TESTING LABORATORY OR
APPROVED BY THE DEPARTMENT.
11. CONDUITS SHOULD BE PAINTED TO MATCH EXISTING
ROOF AND WALL COLORS
12. ALL WORK SHALL BE IN ACCORD WITH THE 2013 CBC, 2013
CEC AND 2011 NEC WITH SPECIAL ENPHASIS ON ARTICLE 690
13. A SINGLE CONDUCTOR SHALL BE PERMITTED TO BE USED
TO PERFORM THE MULTIPLE FUNCTIONS OF DC GROUNDING,
AC GROUNDING
AND BONDING BETWEEN AC AND DC SYSTEMS AS PER NEC
690.47(C) AND SIZED AS PER SEC 250.122
14. EQUIPMENT GROUND CONDUCTOR REQUIRED IN
RACEWAYS SIZED PER CEC 250-122.
15. PER ART 250.92. NON -CURRENT CARRYING METAL PARTS
OF EQUIPMENT SHALL BE EFFECTIVELY BONDED TOGETHER.
BOND BOTH ENDS OF RACEWAYS
10. WHENEVER A DISCREPANCY IN QUALITY OF EQUIPMENT ARISES ON THE
DRAWING OR SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE
FOR PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES REQUIRED
CODV.'
BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN THE
SPECIFICATIONS TO ENSURE COMPLETE COMPLIANCE AND LONGEVITY OF
OFFICE
THE OPERABLE SYSTEM REQUIRED BY THE ARCHITECT/ENGINEERS.
11. ALL BROCHURES, OPERATION MANUALS, CATALOGS, SHOP
DRAWINGS, ETC. SHALL BE HANDED OVER TO OWNER'S
REPRESENTATIVE AT THE COMPLETION OF WORK
PHOTOVOLTAIC NOTES:
SHEET INDEX
1 1 1 ROOF PLAN
2
SINGLE LINE DIAGRAM
3
CODE REQUIRED SIGNAGE
4
ATTACHMENT LAYOUT
5
INVERTER MAP
6
MODULE MAP
7
INVERTER DATA SHEET
8 MODULE DATA SHEET
9 MODULE CERTIFICATION
10 RACKING DATA SHEET
11 RACKING CERTIFICATION
12 ATTACHMENT DATA SHEET
CUP RTIICIO
Building C)epartment
R 'j,
-11
INSTALLER
West Coast Solar
AridrPsc-
2155 Elkins Way, Suite F
Brentwood, CA 94513
Phone Number:
925-516-3900
Lic 908549
Class C, C-46, C-39
WEST C 0 A S T
tYC,
DESIGNER NAME:
DAVID D.
DATE:
13 APRIL 2016
THE IN �
POWER
SYSTEMtASt%T�2ALL COMq.PLY) WT�H T LLOWING CODES:
2013 CALIFORRI✓ RG?111`9PAL
RxECEIVED
v%
2013 CALIFORNIA RESIDENTIAL CODE
2013 CALIFORNIA BUILDING CODE
APR 1 Lll iJ
2013 CALIFORNIA GREEN BUILDING STANDARDS CODE
C99
2013 CALIFORNIA ENERGY CODE
2013 CALIFORNIA MECHANICAL CODE
��-.
2013 CALIFORNIA PLUMBING CODE
ALL OTHER ORDINANCE ADOPTED BY THE
LOCAL GOVERNING AGENCIES
PROJECT NAME: Joan Thompson Dyer
COMMUI JITY DEVELOPMENT DEPART2.11e35 Almaden Ave, Cupertino, CA 95014
BUI -
1. ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULAis set of plan
SHALL BE TESTED, LISTED AND IDENTIFIED UL 170pbsiteduring
changes c
2. SOLAR SYSTEM SHALL NOT COVER ANY PLUMBING OR MECHAW,,&4rom, -wit
VENTS
The stamping o
3. MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED. be held to per
4. SOLAR INVERTER MUST HAVE A MANUFACTURE of any provisk
INSTALLED DISCONNECTING MEANS THAT PREVENTS
PARALLEL FEEDING UTILITY LINES DURING POWER OUTAGE. BY
5. REMOVAL OF AN INTERACTIVE INVERTER OR OTHER EQUIP"11ENT
SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEE!fffHE NO.
GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC
SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTORS.
D
d specifications MUST be kept at h�
struction. It is unlawful to msake-any ,
orations on'same, or to deviate.
approval from t ' - ' 47ng Official.
s purr and specifications SHALL NOT
)r -a ar ar al of.the violatiori'y,
Ci',r ; a or State
VICINITY MAP
SCALE: NTS
SATELLITE VIEW
SCALE: NTS
PHOTOVOLTAIC SYSTEM SUMMARY
SYSTEM SIZE: DC STC: 3.64 KW
SYSTEM SIZE: AC CEC 3.14 KW
SOLAR MODULES: (14) HYUNDAI HiS-S
MICRO INVERTERS: (14) M215-60-21-L-81
MOUNTING SYSTEM: IRONRIDGE ROO
ELECTRICAL INFORMATION:
MAIN SERVICE PANEL BUS SIZE: 125A
MAIN SERVICE BREAKER SIZE: 100A,
BUILDING INFORMATION: 6 %
TWO STORY HOUSE c� D
CONSTRUCTION TYPE: V-B
OCCUPANCY: R
ROOF: ASPHALT SHINGLE
TRUSSES: 2"X4" @ 24" O.C.
(BK)
PHOTOVOLTAIC ARRAY
(14) Hyundai 260 W Solar Modules (HiS-S260 RG (BK))
(14) Enphase Energy (M215-60-2LL-S22-IG)
UNIT INDEX
MSP
(E) 125A Main Service Panel
SP
(N) 100A Sub Panel
J/B
(N) Junction Box
M215 Micro Inverter
Solar Module
EMT Type Conduit
B.O.S. LOCATION MAP
min 4'"
o O
(N)Sub Panel
(E)Main
Service Panel
South Side view
4 M2
Solar Array 2
10 Hyundai 260W
10 M215 Micro -Inverters
Pitch: 37 Deg
7
fire setback j/
4=�0 �../
Almaden Ave
FROM JUNCTION BOX TO ROOF EAVE EMT TYPE CONDUIT WILL RUN OVER
THE ROOF AT 1 1/2" HEIGHT, THEN UNDER THE EAVE TO PV EQUIPMENT
(CD
CUPERTINO
Budding Department
REVIEWED FOR CODE COMPLIANCE
Reviewed By:
N
0°
W E
270° 90°
s
180°
SCALE
0 1 5 loft
General Notes
ROOF PLAN
Drawn By: David D.
No.
Revision/Issue
Date
CONTRACTOR
West Coast Solar
Address:
2155 Elkins Way, Suite F
Brentwood, CA 94513
Phone Number:
925-516-3900
Lic# 908549
WEST COAST
ILI R
Joan Thompson Dyer
21835 Almaden Ave,
Cupertino, CA 95014
oa.
Apr 13, 2016
s.r
SWIM
AS INDICATED
PV SYSTEM
NOTE:
A continuity of equipment grounding shall be provided with a minimum of #6 AWG copper grounding
conductor between rail interconnection, and rail end connection
#6 AWG EGC
COPPER WIRE
PV ARRAY 2
10 HYUNDAI
260 WATT MODULES,
10 ENPHASE M215
MICROINVERTERS
PV ARRAY 1
4 HYUNDAI
260 WATT MODULES,
4 ENPHASE M215
MICROINVERTERS
PV ARRAY INFORMATION
14 HYUNDAI 260WATT SOLAR MODULES
MODEL # HiS-S260 RG (BK)
14 ENPHASE ENERGY MICROINVERTERS
MODEL # M215-60-2LL-S22-IG
NUMBER OF BRANCH CIRCUITS: 1
NUMBER OF MODULES IN BRANCH CIRCUIT: 14
WATTS STC: 14 * 260W = 3640W
MAX AC VOLTAGE: 120/240V
PV MODULE RATINGS # STC
SHORT CIRCUIT CURRENT I -SC = 8.90A
MAXIMUM POWER CURRENT I -MP = 8.40A
OPEN CIRCUIT VOLTAGE V-OC = 37.9V
MAXIMUM POWER VOLTAGE V-MP = 31.1V
INVERTER RATING
PEAK PWR TRACKING VOLTAGE = 27-39 V
CEC EFFICIENCY
= 96.5 %
ENCLOSURE:
NEMA6
MAXIMUM INPUT CURRENT
= 10 A
MAXIMUM OUTPUT CURRENT
= 0.9 A
MAXIMUM INPUT POWER
= 210 - 300 W
MAXIMUM OUTPUT POWER
= 215 W
AA
J BOX2
NEMA 3R
120
;FEET
J BOX1
NEMA 3R
All the photovoltaic systems wires that on the roof and
side of the building shall be protected against physical damage
ENPHASE
ENVOY-S
BREAKER
INSTALL 2P
20A CB(PV)
AT OPPOSITE END
OF BUS FROM
MAIN FEEDER CB
(3)#8 AWG THWN-2
15A
15A
3/4" EMT
CONDUIT NEW 100A SUB PANE
10 FEET 120/240V
NEMA 3R
[ ACA ] FROM PV MODULES TO J-BOX
(3) ENPHASE TRUNK CABLE #12 AWG, PV WIRE + (1) #6 AWG BARE CU EGC
FREE IN THE AIR
[ AC.2 ] FROM J-BOX2 TO J-BOX1,FROM J-BOX1 TO SUB PANEL
(3) #10 AWG THWN-2 + (1) #8 AWG CU EGC, 3/4" EMT TYPE CONDUIT, 30 FEET
# OF MICROINVERTERS IN BRANCH CIRCUIT: 14
EACH INVERTER OUTPUT MAX CURRENT: 0.9 A
BRANCH CIRCUIT CURRENT: 14 * 0.9 *1.25 = 15.8 A
BREAKER SIZE PER B. CRCT - 20A
MAXIMUM CONTINUOUS CURRENT: 15.8 A
RACEWAY HEIGHT FROM ROOF 1 z' (TEMP - 39 + 22 = 61 C)
TEMP. DERATE FACTOR - 15.8 A / 0.58 = 27.2 A
WIRE SIZE FROM NEC TABLE 310.15(b)16 - 10 AWG
AMBIENT TEM FACTOR 0.58 PER NEC 310.15(b)(2)(a)
UTILITY
M
0
100A TOP
FEED
40A U)
Z)
m
(1)#8 AWG GROUND <
N
EXISTING
125A MAIN
SERVICE PANEL
120/240V,1 P,3W,
L OVERHEAD #3 AWG
EXISTING BUILDING
GROUND SYSTEM
TO CW PIPE AND'UFER'
/'
Connection to the Interior metal water piping
shall be made within 5 feet from the point of
entrance. 250.68(C) (1)
CUPERTINO
r,y�
NY!(r..K
r�;
Building Department
PP1D201S
0 i.
REVIEWED FOR CODE COMPLIANCE
Reviewed By; ✓�
MAIN PANEL RATING
SPLIT PHASE: 3W, 120/240V
BUSBAR RATING = 125A
MAIN SERVICE BREAKER = 100A TOP FEED
120% RULE:
MAX ALLOWED FEED: 150A
ACTUAL FEED:
100 WSP" + 20 A "SOLAR" = 120 A <= 150A MAX
OUTPUT CALCULATIONS
PV SYSTEM MAX DC OUTPUT:
14 * 260W = 3640W
PV SYSTEM MAX AC OUTPUT:
(14) HiS-S260 RG (BK)
(14) M215-60-2LL-S22-IG
Pmax (PTC Rating) PER MODULE: 232.8W
232.8W * 14 = 3.23 KW
3.23 KW * 96.5% CEC INVERTER = 3.14KW
General Notes
SINGLE LINE
DIAGRAM
Drawn By: David D.
No.
Revision/Issue
Date
CONTRACTOR
West Coast Solar
Address:
2155 Elkins Way, Suite F
Brentwood, CA 94513
Phone Number:
925-516-3900
Lic# 908549
sit 1.
WEST
ES T COAST
�
INC
Joan Thompson Dyer
21835 Almaden Ave,
Cupertino, CA 95014
Dot.
Apr 13, 2016
s.r
2
sm1.
AS INDICATED
PV SYSTEM
(STICKER TO BE LOCATED ON
CONDUIT WITH DC CURRENT
EVERY 4' HORIZONTALLY OR
10' VERTICALLY AND 1' FROM
EACH SIDE OF A BEND)
O
0
O
O
(TO BE LOCATED ON
SUB -PANEL ONLY
WHEN SUB -PANEL IS
DEDICATED FOR PV ONLY)
4
H
(STICKER LOCATED
INSIDE PANEL
NEXT TO SOLAR BREAKER)
(STICKER LOCATED
INSIDE PANEL
BELOW PV BREAKER)
(STICKER LOCATED
ON THE PV SUB PANEL)
Permanent directory or plaque providing location of service disconnecting
means and photovoltaic system disconnecting means, if not located at the
same location. (Plaques shall be metal or plastic, with engraved or machine printed
letters, or electro-photo plating, in a contrasting color to the plaque. Plaques shall be
permanently attached to the equipmenq or in the required location using an approved
method that is suitable to withstand the environment to which it is exposed. Plaques
and signage shall meet legibility, defacemet, exposure and adhesion requirements of
Underwriters Laboratories marking and labeling system 969(UL969).
Plaques will have red background & white lettering.
MARKINGS, LABELS AND WIRING SIGNS
A. Purpose: Provide emergency responders with appropriate warning and
guidance with respect to isolating solar electric system.
This can facilitate identifying energized electrical lines that connect solar panels
to the inverter, as these should not be cut when venting for smoke removal
B. Main Service Disconnect.
1. Residential buildings - The marking main be placed within the main service
disconnect. The marking shall be placed
outside cover if the main service disconnect is operable with the service panel
closed.
2. Commercial buildings - Tha marking shall be placed adjacent to the main
service disconnect clearly visible from the location where the level is operated
3. Markings: Verbiage, Format and Type of Material.
a. Verbiage: CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED
b. Format: White lettering on a red background. Minimum 3/8 inches letter
height. All letters shall be capitalized. Arial or similar font, non bold.
c. Material: Reflective, weather resistant material suitable for the environment
(use UL - 969 as standard for weather rating). Durable adhesive materials meet
this requirement.
C.Marking Requirements on DC conduit, raceways, enclosures, cable
assemblies, DC combiners and junction boxes:
1. Markings: Verbiage, Format and Type of Material.
a. Placement : Markings shall be placed every 10 feet on all interior and exterior
DC conduits, raceways, enclosures, and cable assemblies,
at turns, above and for below penetrations, all DC combiners and junction boxes
b. Verbiage: CAUTION: SOLAR CIRCUIT Note: The format and type of material
shall adhere to ' V. V-3b, c" of this requirement.
c. Inverters are not required to have caution markings
1.Marking is required on all interior and exterior DC conduit
raceways, enclosures,cable assemblies,and junction boxes,combiner boxes and
disconnects.CFC 605.11.1
2.The materials used for marking shall be reflective,weather resistant material
suitable for the environment.
Minimum 3/8 "letter height; all upper case letters Aria] or similar font; Red
background with white lettering. CFC 605.11.1.1
3.Marcking shall contain the words: WARNING: PHOTOVOLTAIC POWER
SOURCE. CFC 605.11.1.2
4.Marcking shall be placed adjacent to the main service disconnect in a location
clearly visible from the location where the disconnect is operated CFC 605.11.1.3
SOLAR PV ARRAY WITH
INVERTER TYPE: MICRO
s„J`1J t
CAUT10-wain,.
;.� iilildil geAarnl
r,
POWER TO THIS BUILDING IS ALSO SUPPLIED 3
FROM THE FOLLOWING SOURCES'WtTN— E f
PV EQUIPMENT LOCATED AS �tIEV�EWED
FOR CODE Cov
Reviewed By:�
O
Almaden Ave
SOLAR PV ARRAY WITH
General Notes
e
CODE REQUIRED
SIGNAGE
Drawn By: David D.
No.
Revision/Issue
Date
CONTRACTOR
West Coast Solar
Address:
2155 Elkins Way, Suite F
Brentwood, CA 94513
Phone Number:
925-516-3900
Lic# 908549
�nt
WEST COAST
'�'
INC,
Joan Thompson Dyer
21835 Almaden Ave,
Cupertino, CA 95014
Dd.
Apr 13, 2016
Sh a
3
Smh
AS INDICATED
PrOwt
PV SYSTEM
FLASH MOUNTING DETAIL
MODULE WEIGHT (Ibs)
37.9
# OF MODULES
14
TOTAL MODULE WEIGHT (Ibs)
530
RACK WEIGHT (Ibs)
106
MICROINVERTERS WEIGHT (Ibs)
48
TOTAL SYSTEM WEIGHT (Ibs)
684
# OF STANDOFFS
32
MAX SPAN BETWEEN STANDOFFS (in)
48
LOADING PER STANDOFF (Ibs)
21.4
TOTAL AREA (sgft)
252
LOADING (PSF)
2.71
Dking
Brace
ATTACHMENT DETAILS
1. Ironridge Racking System
2. Ironridge Flash Foot Attachment
3. Racking loading calculations were performed for ASCE 7-10 wind speeds @ 110 mph for B and C
exposure categories and ASCE 7-10 Seismic Design Category E.
4. Roof attachment hardware to be mounted to existing structure
(2"x4"@24" O.C. Trusses) at 48" O.C. rail spans or less.
5. Lag bolts are 5/16" X 3.5" stainless steel with 2.5" minimum embedment into the roof rafters.
6. Roof sheathed with 1/2" plywood and upper surface is faced with felt paper.
Finished roof surface is Asphalt Shingle.
7. Mounts or/and mounting hardware will be sealed with Tremco Vulkem 116 Polyurethane Sealant or
equivalent.
IRONRIDGE FLASH FOOT ATTACHMENT
IRONRIDGE ROOF MOUNT XR10 RAIL
— — — — — — — — — — — EXISTING 2" BY 4", 24 O.C. ROOF TRUSSES
CUPERTINO
Building Department
=D FOR CODE COMPLIi
viewed BY:
General Notes
ATTACHMENT
LAYOUT
Drawn By: David D.
No.
Revision/Issue
Date
CONTRACTOR
n-N.h,
West Coast Solar
Address:
2155 Elkins Way, Suite F
Brentwood, CA 94513
Phone Number:
925-516-3900
Lic# 908549
WEST COAST
@ 00 L 2%
IYC.
IgCE
Joan Thompson Dyer
21835 Almaden Ave,
Cupertino, CA 95014
0eh
Apr 13, 2016
err
seer
AS INDICATED
PV SYSTEM
3.64 KW DC (STC)
14 HYUNDAI
HiS-S260 RG (BK)
260W MODULES &
ENPHASE ENERGY
M215-60-2LL-S22-IG
MICRO INVERTERS
ENVOY SERIAL #:
ENVOY LOCATION:
C U PEE RT I t
COMMUNICATION LEVEL: 1 Building Depar-;Ll
ETHERNET BRIDGE INSTALLED:
1041611111:&1
LP -1 ?)
Reviewed By:
General Notes
INVERTER
MAP
Drawn By: David D.
No.
Revision/issue
Date
CONTRACTOR
Fb� H— A, A* —
West Coast Solar
Address:
2155 Elkins Way, Suite F
Brentwood, CA 94513
Phone Number:
925-516-3900
Lic# 908549
WEST COAST
cin t
�11PLIANCF
Joan Thompson Dyer
21835 Almaden Ave,
Cupertino, CA 95014
od.
Apr 13, 2016
Sh.A
SmN
S INDICATED
A -5
ftw
PV SYSTEM
3.64 KW DC (STC)
14 HYUNDAI
HiS-S260 RG (BK)
260W MODULES &
ENPHASE ENERGY
M215-60-2LL-S22-IG
MICRO INVERTERS
CUPERTINO
k.y n�k'
Building Department
REVIEWED FOR CODE COMPUA
Reviewed By: 9�" %T
General Notes
MODULE
MAP
Drawn By: David D.
No.
Revision/Issue
Date
CONTRACTOR
West Coast Solar
Address:
2155 Elkins Way, Suite F
Brentwood, CA 94513
Phone Number:
925-516-3900
Lic# 908549
W.
�_..
WEST COAST
L -' PR
NYC
Joan Thompson Dyer
21835 Almaden Ave,
Cupertino, CA 95014
Dal.
Apr 13, 2016
s.w
6
smh
AS INDICATED
AvI t
PV SYSTEM
Enphase`1 M215 Microinverter // DATA
Enphase'y Microinverters INPUT DATA (DC) M215-60-2LL-S22-IG, M215-60-2LL-S25-IG
Recommended input power (STC) 190 - 270 W
EnphaseeM215 Maximum input DC voltage 48 V
Peak power tracking voltage 27 V - 39 V
Operating range 16 V - 48 V
Min/Max start voltage 22 V / 48 V
Max DC short circuit current 15 A
OUTPUT DATA (AC) @208 VAC @240 VAC
Peak output power 225 W 225 W
E P Rated (continuous) output power 215 W 215 W
MOE
Nominal output current 1.03 A (A rms at nominal duration) 0.9 A (Arms at nominal duration)
Nominal voltage/range 208 V / 183-229 V 240 V / 211-264 V
Nominal frequency/range 60.0 ! 57-61 Hz 60.0./ 57-61 Hz
r , Extended frequency range 57-62.5 Hz 57-62.5 Hz
The Enphase' M215 Microinverl;er with integrated ground delivers increased energy harvest and
reduces design and installation complexity with its all -AC approach. With the advanced M215, the DC
circuit is isolated and insulated from ground, so no Ground Electrode Conductor (GEC) is required
for the microinverter. This further simplifies installation, enhances safety, and saves on labor and
materials costs.
The Enphase M215 integrates seamlessly with the Engager Cable, the Envoy' Communications
Gateway', and Enlighten', Enphase's monitoring and analysis software.
Power factor
>0.95 >0.95
Maximum units per 20 A branch circuit
25 (three phase) 17 (single phase)
Maximum output fault current
850 mA rms for 6 cycles 850 rnA rms for 6'cycles
EFFICIENCY
CEC weighted efficiency, 240 VAC
96.5%
CEO weighted efficiency, 208 VAC
96.5%
Peak inverter efficiency
96.5°%
Static MPPT efficiency (weighted, reference EN50530)
99.4 %
Night time power consumption
65 mW max
MECHANICAL DATA
Ambient temperature range
Dimensions (WxHxD)
Weight
Cooling
Enclosure environmental rating
Connector type
FEATURES
Compatibility
Communication
-40°C to +651C
171 mm x 173 mm x 30 mm (without mounting bracket)
1.6 kg (3.4lbs)
Natural convection - No fans
Outdoor - NEMA 6
M215-60-2LL-S22-IG: MC4
M215-60-2LL-S25-IG: Amph
of H4
Compatible with 60-cell PV modules.
Power line
CL
Sui1d
PRODUCTIVE
SIMPLE
RELIABLE
tip?;
Integrated ground The DC circuit meets the requirements for ungrounded Panaysfm,;
Maximizes energy production
- No GEC needed for microinverter
More than 1 million hours of testing
'Cable No•�m'�
NEC 690.35. Equipment ground is provided in the Engagadditional GEC or ground is required. Ground fault protection (GFP) is
- Minimizes impact of shading,
- No DC design or string calculation
and millions of units shipped
integrated into the microinverter. REVIEWED r Q IT
dust, and debris
required
Industry -leading warranty, tlp to 25
Monitoring Enlighten Manager and MyEnlighten monitoring options
No single point of system failure
- Easy installation with Engage
years
{�
Compliance UL1741/IEEE1547, FCC Part 15 Class B, CAN/CSA-C22.2 NO. 0-M91RGVieWed
Cable
0.4-04, and 107.1-01
Frequency ranges can be extended beyond nominal if required by the utility
[] elnphase- Sla® To learn more about Enphase Microinverter technology, [ i enphasee
� E N E R G Y C US visit enphase.com E N E R G Y
02015 Enphase Energy. All rights reserved. All tradamarks or brands in iris document are registered by their respective owner. MKT M69 Rev 1.0
General Notes
INVERTER
DATA SHEET
Drawn By: David D.
No.
Revision/Issue
Date
CONTRACTOR
West Coast Solar
Address:
2155 Elkins Way, Suite F
Brentwood, CA 94513
Phone Number:
925-516-3900
Lic# 908549
WEST COAST
j
t
INC
Department
it n 1^
I .1 0II
CODE COfy PLI N(D'E
na}d Icy,. • ,�
Joan Thompson Dyer
21835 Almaden Ave,
Cupertino, CA 95014
ow
Apr 13, 2016
a.A
7
ScaN
AS INDICATED
�r
PV SYSTEM
m"Oilhi-green.com/solar
L".i`•'_<i:S1
Multi -crystalline Type �
Hyundai Heavy Industries was founded in 1972 and is a Fortune 500 company. The company employs more than 48,000 people, and has a global
leading 7 business divisions with sales of 60.2 Billion USD in 2012. As one of our core businesses of the company, Hyundai Heavy Industries is
committed to develop and invest heavily in the field of renewable energy.
Hyundai Solar is the largest and the longest standing PV cell and module manufacturer in South Korea. We have 600 MW of module production
capacity and provide high -quality solar PV products to more than 3,000 customers worldwide. We strive to achieve one of the most efficient PV
modules by establishing an R&D laboratory and investing more than 20 Million USD on innovative technologies.
Multi -crystalline Type
HIS-M250RG I HiS-rA255RG 1 HiS-M260RG
RG®Series Mono -crystal line Type
HiS-S260RG I HiS-5265RG I HiS-S270RG
e
(1i,i-eC.50;`iiC:; l..lha#%:ti.w'=.''kFiti.r
998 nim (39.29")(W) x 1,640 mm (64.57")(L) x 35 mm (1.38")(H)
Approx. 17.2 kg (37.9lbs)
60 cells in series (6 x10 matrix) (Hyundai cell, Made in Korea)
4 mm' (12AWG) cables with polarized weatherproof connectors,
IEC certified (UL listed), Length 1.0 m (39.4)
IP68, weatherproof, IEC certified (UL listed)
3 bypass diodes to prevent power decrease by partial shade
Front: High transmission low -iron tempered glass, 2.8 mm (0.11")
Encapsulant:EVA Back Sheet: Weatherproof film
Clear anodized aluminum alloy type 6063
s
IEC 61215 (Ed.2) and IEC 61730 by VIDE
UL listed (UL 1703), Class C Fire Rating
• Output power tolerance +3/-0 %
ISO 9001:2000 and ISO 14001:2004 Certified
Advanced Mechenical Test (5,400 Pa) Passed (IEC)
/ Mechanical Load Test (40lbs/ft7) Passed (LIQ
Ammonia Corrosion Resistance Test Passed
• IEC 61701 (Salt Mist Corrosion Test) Passed
e?(.d�r;3''S :-"i' ,' iNlour i�9
Delivered ready for connection
IEC (LIQ certified and weatherproof connectors
Integrated bypass diodes
LIi-:�i=�1 )"i1/L!q"M r'i63:P
10 years for product defect
10 years for 90 % of warranted min, power
25 years for 80 % of warranted min. power
A Important Notice on Warranty
TnewarranDe:applvonlyto'her^:'mcdulesv:itillyundai Ieavyinocsrl.SCG__td:s
logo (shown bet ,v) and PT -,duct serial nurrber cn it.
Ptrcrc� 6 Lima
(cg s
HYU N DAI
HEAVY INDUSTRIES CO.,LTD.
Nominal output (Pmpp)
Voltage at Pmax (Vmpp)
Current at Pmax (Impp)
Open circuit voltage (Voc)
Short circuit current (Isc)
Output tolerance
No. of cells & connections
Cell type
Module efficiency j
Temperature coefficient of Pmpp I
Temperature coefficient ofVoc j
Temperature coefficient of Isc
W
250
255
260
V
30.9
31.0
31.1
A
8.1
8.2
8.4
V
37.4
37.6
37.7
A
8.7
8.8
8.9
Q'6
+3/-0
PCs
60 In series
6" Multi -crystalline
silicon (Hyundai cell, Made
in Korea)
°.v
15.3
15.6
15.9
%/K
-0.43
.0.43
-0.43
46/K
-0.32
-0.32
-0.32
461K
0,048
0.048
0.048
3T All datJ al S I(_ 616ridaid Iet L::,IdI11Ul'i). AI;UV(' 1j : If,; I,, t11,i(jed :Yitl"UUl rtllUl nut; c.
I Mono -crystalline Type I
t t'
�W
Nominal output (Pmpp)
260
265
270
Voltageatpmax(Vriipp)
tti
V
1
31.1
31.3
31A
Current at Pmax (Impp)
A
8.4
8.5
8.6
Open circuit voltage (Voc)
V
37.9
38.1
38.2
Short circuit current (Isc)
A
8.9
9.0
9.2
Outputtolerance
I %
+3i-0
No. of cells & connections
1 PCs
60 in series
Ceti type
6"Mono-crysta[line silicon (Hyundai cell, Made in Korea)
Module efficiency
%
15.9
162
16.5
Temperature coefficient of Pmpp
%/K
-0.45
-0.45
-0.45
Temperature coefficient of Voc
%/K
-0.33
-0.33
-0.33
Temperature coefficient of Isc
0,'9/K
0.032
0.032
0.032
X ;II dal a at Sir (tit: •i,bid I s1('cndit`.nr;i A;:nve dF-n may F.e rhanr11',vilhnn1
I Module Diagram I
(unit: Min, inch) I I-V Curves I
C-It IAI
a
B 1,000YJlrn' _ iSc
, \ a
+x atin
75(03') y -6SC
0 HORS
tl (I} DETAILA
39S'; 0537I bfllSLOTTKYI,
4m 166!F& 4nm'CARLS E(0.3.1
CDNYcCTOR CaNNKTOR d u
�' CurteniW Voka9e lh
.GROUNDMAW. $ DETAILB
Id At V) -� -13Y, inr
GRDUNDF.OIE b'h V,m
r fiO Pam'' � 630V
951137561 v Li
C-'Y s< (( �iC 2534^961 U%' yi`i�,'` Gd Ll l I` 11
SECTIONOC t
Installation Safety Guide
46C±2
Only qualified personnel should install or perform maintenance. �Cn,.,- f ,, ( =_ -REVIEWED F O R
Be aware of dangerous high DC voltage. „J~ tt , - DC 1,000 V (IEC)
Do not damage or scratch the rear surface of the module. L -- ' DC600V (Ut), Reviewed E
Do not handle or install modules when they are we -' h €k' - 15 A
t
Sales & Marketing 2" FL, Hyundai Bldg., 75, YulgokoJonyno-gu, Seoul 110-793, Korea HYU N DAI
rise
Tel: +82-2-74s-sao6,74zz,6525 Fax:+A2-2-746-7675 HEAVY INDUSTRIESCo.,LTD.
General Notes
MODULE
DATA SHEET
Drawn By: David D.
No.
Revision/Issue
Date
CONTRACTOR
meN_ aAa-
West Coast Solar
Address:
2155 Elkins Way, Suite F
Brentwood, CA 94513
Phone Number:
925-516-3900
Lic# 908549
WEST COAST
R:INO
)cparment
. DE COtlilPUANC.E
Hord 11a. a/`1
Joan Thompson Dyer
21835 Almaden Ave,
Cupertino, CA 95014
Wt.
Apr 13, 2016
s d
8
S.I.
AS INDICATED
Aord
PV SYSTEM
CERTIFICATE OF COMPLIANCE
Certificate Number 20150331-E325005
Report Reference E325005-20110831
Issue Date 2015-MARCH-31 j
Issued to: HYUNDAI HEAVY INDUSTRIES CO LTD
1-5 DAEJANG-RI SOI-MYEON
EUMSEONG-GUN
CHUNGCHEONGBUK-DO 369-872 KOREA
This is to certify that PHOTOVOLTAIC MODULES AND PANELS
representative samples of "HiS-SxxxMF, HiS-MxxxMF, HiS-SxxxMG and HiS-MxxxMG
Series with specific construction described in installation
instructions compliant to Photovoltaic Module Fire
Performance Type 1" 111
Have been investigated by UL in accordance with the
Standard(s) indicated on this Certificate.
Standard(s) for safety: The fire test method was in accordance to "Standard For
Safety For Flat -Plate Photovoltaic Modules and Panels", UL
1703, 3rd Edition, dated December 18, 2014.
ULC 0RD/C1703-01 "Flat -Plate Photovoltaic Modules and
Panels", 1
Additional Information: See the UL Online Certifications Directory at
www.u1.com/database for additional information
Only those products bearing the UL Certification Mark should be considered as being covered by UL's
Certification and Follow -Up Service.
Look for the UL Certification Mark on the product'
l
F`''y'";'''r"'°•'`� Building Dep
REVIEWED FOP. COD
Reviewed By. ':'
Bmce %bhmnhot:, Assistant Char Engineer, alabat Inspection and Field Servicas
UL LLC
Any Information and dmunettlat'mn involving UL Nark services am provided on behalf of UL LLC JUL) of any authariwd licensee or UL For questions, please
Contact a local UL Cost- Service Rep -at,, live aty W W.ul.Com'contaGius
Page 1 of 1
General Notes
MODULE
CERTIFICATION
Drawn By: David D.
No.
Revision/Issue
Date
CONTRACTOR
rim Re n. a aa—
West Coast Solar
Address:
2155 Elkins Way, Suite F
Brentwood, CA 94513
Phone Number:
925-516-3900
Lic# 908549
WEST COAST
11C
'10
L-nent
OMPLIANCE
AaJrC tar.. • aen.
Joan Thompson Dyer
21835 Almaden Ave,
Cupertino, CA 95014
Dow
Apr 13, 2016
0.4
9
Sovh
AS INDICATED
r'A)Al
PV SYSTEM
IRONRIDGE
Staijt for solar'' toughest roofs
Roof Mount System
IronRidge builds the strongest roof mounting system in solar. Every component has been tested to the limit
and proven in extreme environments.
Our rigorous approach has led to unique structural features, such as curved rails and reinforced (lashings, and
is also why our products are fully certified, code compliant and backed by a 20-year warranty.
i Strength Tested
I All components evaluated for superior
structural performance.
Class A Fire Rating
Certified to maintain the fire resistance
rating of the existing roof.
PE Certified
Pre -stamped engineering letters
LC available in most states.
Design Software
Online tool generates a complete bill of
LL materials in minutes.
f j
Integrated Grounding
20 Year Warranty
fI
UL 2703 system eliminates separate/
Twice the protection offered by
module grounding components.
competitors.
)\IR R,aiIS
XR10 Rail
A low -profile mounting rail
for regions with light snow.
• 6' spanning capability
• Moderate load capability
• Clear anodized finish
FlashFoot
XR100 Rail XR1000 Rail Internal Splices e
The ultimate residential A heavyweight mounting All rails use internal splices
solar mounting rail. rail for commercial projects. for seamless connections.
• 8'spanning capability 12'spanning capability Self -tapping screws
• Heavy load capability Extreme load capability Varying versions for rails
• Clear & black anod. finish Clear anodized finish Grounding Straps offered
Slotted L-Feet Standoffs Tilt Legs
AERMI
Anchor, flash, and mount Drop -in design for rapid rail Raise flush or tilted Tilt assembly to desired
with all -in -one attachments. attachment. systems to various heights. angle, up to 45 degrees.
Ships with all hardware High -friction serrated face Works with vent flashing Attaches directly to rail
• IBC & IRC compliant Heavy-duty profile shape Ships pre -assembled Ships with all hardware
• Certified with XR Rails Clear & black anod. finish Lengths from 3" to 9" Fixed and adjustable
Clangs Q't Grounding
End Clamps Grounding Mid Clamps Ct!:-) T Bolt Grounding^ Lugs (5- Accessories
"ta s I
Slide in clamps and secure Attach and ground modules Ground system using the Provide a finished and
modules at ends of rails. in the middle of the rail. rail's top slot. organized look for rails.
r,.sr.,..-
• Mill finish & black anod. Parallel bonding T-bolt Easy top -slot mounting Snap -in Wir°hGl ps w_ _ i % L ( i
• Sizes from 1.22" to 2.3" Reusable up to 10 times Eliminates pre -drilling Perfected d Caps l_a Build
• Optional Under Clamps Mill & black stainless Swivels in any direction UV -protects polymer ` l
Free Resources
Design Assistant A NABCEP Certified Trainini, EVIEVVEJ r Q
Go from rough layout to fully 17 y' Earn free continuing education credit !
engineered system. For tree. ^� m while learning more about our systemeVeWed
Go to ironRicl9e.co,n/rnt � 7 � Go to Iron Ridgaxom/'training
sryr,, z; 4
General Notes
RACKING
DATA SHEET
Drawn By: David D.
No.
Revision/Issue
Dote
CONTRACTOR
West Coast Solar
Address:
2155 Elkins Way, Suite F
Brentwood, CA 94513
Phone Number:
925-516-3900
Lic# 908549
WEST COAST
ir+c
= ERTINO
g Department
3 2016
-•ODE COMPLIANCE
Joan Thompson Dyer
21835 Almaden Ave,
Cupertino, CA 95014
ocrt.
Apr 13, 2016
s.r
S.I.
AS INDICATED
10
nala
PV SYSTEM
8431 Murphy Drive
Middleton, WI 53562 USA
Telephone: 608.836.440 0
Facsimile: 608.831.9279
www.intertek.com
kl \(,,8;,.sn !J e Hfi ca fl o o It O ti r r i!' 1 ey�
In the basis of the tests undertaken, the sample(s) of the below product have been found to comply with the requirements of
the referenced specifications at the time the tests were carried out.
(Applicant Name & Address:
Product Description:
Ratings_& Principle
Characteristics:
Iron Ridge; Inc.
1495 Zephyr Ave.
Hayward, CA 94544
USA
XR Rails with Integrated Grounding.
Fire Class Resistance Rating:
-Flush Mount (Symmetrical). Class A Fire Rated for Low Slope applications when using Type 1, 2
and 3, listed photovoltaic modules. Class A Fire Rated for Steep Slope applications with Type1,
2 and 31 listed photovoltaic modules. Tested with a 5" gap (distance between the bottom the
module frameand the roof covering),, per the standard this system can be installed at any gap
allowed by the manufacturers installation instructions. No perimeter guarding is required.
Models: 151-616D-005, 51-61GD-005B, 51-5000-001 and 517-65-001
Brand Name:
Relevant Standards:
Verification Issuing Office:
Date of Tests:
Test Report Nu
IronRidge Roof .Mount
UL 2703 (Section 15.2 and 15.3) Standard for Safety Mounting Systems, Mounting Devices,
Clamping/Retention Devices, and Ground Lugs for Use.with Flat -Plate Photovoltaic Modules
and Panels, First Edition dated Jan. 28, 2015 Referencing UL1703 Third Edition dated Nov. 18,
2014, (Section 31.2) Standard for Safety for Flat -Plate Photovoltaic Modules and Panels.
Intertek Testing Services NA, Inc.
8431 Murphy Drive
Middleton, WI 53562
08/27/2014to 03/17/2015
101769343MID-001r1, 101769343MID-001a, 101915978MID-001 & 101999492MID-001ar1-cr1.
This verification is part of the full'test report(s) and should be read in conjunction with them. This report does not automatically
imply product certification.
Completed by:
Chad Naggs
Reviewed by:
" Gregory Allen
Title:
Technician II, Fire Resistance
Title:
Engineering Team Lead, Fire Resistance
r ��
��r!
Signature:
Signature:
µ_
Date:
03/30/2015
Date:
03/30/2015
This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek, and its Client. intertek's responsibility and liability are
limited to the terms and conditions of the agreement. Intertek ossumes no liability to any party, other than to the Client in accordance with the agreement, for an}, loss, expense
or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one ofits
marks for the sale or advertisement of the tested material, product or service .must first be approved in writing by Intertek. The observations and test inspection results
referenced in this Verification are relevant only to the sample tested/inspected. rhis Verification by itself does not imply that the material, product, or service is or has ever been
under an Intertek certification program.
GIFT-OP-11a (24-MAR-2014)
CUPERTlh
FJUiiuln;
[[jj1i
!Depanr
y"
REVIEWED FOR CODE C(
Reviewed By:
General Notes
RACKING
CERTIFICATION
Drawn By: David D.
No.
Revision/Issue
Date
CONTRACTOR
Am N— & .&—
West Coast Solar
Address:
2155 Elkins Way, Suite F
Brentwood, CA 94513
Phone Number:
925-516-3900
Lic# 908549
WEST COAST
r""V r LL [FRD
IO
(lent
I
MC' LIANCE
Joan Thompson Dyer
21835 Almaden Ave,
Cupertino, CA 95014
Der
Apr 13, 2016
a.w
SwN
AS INDICATED
PV SYSTEM
0
r
IRONRIDGE
Rapid & Secure Solar Arta hrnents
IronRidge FlashFootTM is an all -in -one solar mounting
product for composition shingle roofs that eliminates the
need for separate standoffs, (lashings, and L-feet.
FlashFoot incorporates a number of structural and
waterproofing features to securely attach IronRidge
Rails to roof structures, while also protecting against
water intrusion and weather damage.
0.050,
Load Distribution Plate
A solid metal plate below the L-toot t
increases the FlashFoot's structural
strength and prevents any deformation
of the flashing during installation.
Cedlfled compliant
1gPM0 nigh IBC end IRC.
EB 4
FlashFoot"I
Dual Mechanical Seal
At the core of the FlashFoot, a pre -installed
rubber bushing forms a dual mechanical
seal, with its exterior compressed against
the cavity of the L-foot and its interior tightly
wrapping around the shaft of the lag bolt.
Water Shedding Design
A wide flashing layer combined with an
elevated sealing platform maximizes the
FlashFoot's water shedding ability.
Installation Overview
Tools Required: tape measure, chalk line, stud finder, roofing bar, caulking gun with an approved sealant, drill
with 1/4" bit and 1/2" socket.
Locate rafters and snap vertical and horizontal lines
to mark locations of flashings. Drill 1/4" pilot holes,
then backfill with an approved sealant.
Line up pilot hole with flashing hole and insert lag
bolt through bonded washer, L-Foot, and flashing.
Tighten lag bolt until fully seated.
Testing & Certification
Slide flashing, between 1st and 2nd course, so the
top is at least 3/4" above the edge of the 3rd course
and the bottom is above the edge of the 1 st course.
The FlashFoot is now installed and ready for
IronRidge Rails. With provided L-foot fasteners pre -
loaded into rails, drop rails into open L-foot slots.
FlashFoot is certified for compliance with the International Building Codes (IBC) & International Residential
Codes (IRC) by IAPMO-ES. Mechanical testing conformed to the standard for Testing and Analysis of Joist
Hangers and Miscellaneous Connectors (EC002-2011), and rain testing conformed to the Und r to ��y ��
Laboratory Standard for Gas Vents (UL441-96 Section 25).'<<�: ><' i
Building De
I Dwgl. Fir. Lard, _..s-.....®_...._.-._..� 5Z
I Douglas Rr, Scull,
.4ri
I
i 5x,jeimwv, Syr !,,e, LudgepuM: Rnu {MSR 16501 d higher)
.46
7705
Hem. Fir
( .43
`/�'
I REV I E V Y E
1 Hem. Fir (NctlII _ - - _
.ds
705
i Soulhem Pine
.55
021 Rev e
Spruce. Pine, Fir
.42
I 615
Spruce. Pine. Fir (E o12 million psi and higher grades of MSR and MEQ
t .50
750
. _ � .._._._®� �T� 41['�_--��",��r,?�f py'°Y,i�cY l��ist"w.1`+��:>'G_aru'1; �1'tt-� �% _'�'h.; L•,�i..l�. �s e._1[' S',r'u1,51 �...,.-_�._..�.. �y%/ r�P
-OR CO
red By:
General Notes
ATTACHMENT
DATA SHEET
Drawn By: David D.
No.
Revision/Issue
Date
CONTRACTOR
rn. %— •ran.
West Coast Solar
Address:
2155 Elkins Way, Suite F
Brentwood, CA 94513
Phone Number:
925-516-3900
Lic# 908549
WEST COAST
" tuc
tment
COMPLIANCE
Joan Thompson Dyer
21835 Almaden Ave,
Cupertino, CA 95014
D1W
Apr 13, 2016
NAM
12
S.I.
AS INDICATED
Aopol
PV SYSTEM
CUP RTINt
.dclr%s—
PURPOSE
SMOKE I CARBON MONOXIDE ALARMS
OWNER CERTIFICATE OF COMPLIANCE
COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION
10300 TORRE AVENUE CUPERTINO, CA 95014-3255
(408) 777-3228 . FAX (408) 777-3333 • building(a.cupertino.org
This affidavit is a self -certification for the installation of all required Smoke and Carbon Monoxide Alarms for
compliance with 2013 CRC Section R314, 2013 CBC Sections 420.6 and 907.2.11.2 where no interior access .for
inspections are required.
GENERAL INFORMATION
Existing single-family and multi -family dwellings shall be provided with Smoke Alarms and Carbon
Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds
$1000.00, CRC Section R314 and CBC Sections 9072.11.5 and 420.6 require that Smoke Alarms and/or Carbon
Monoxide Alarms be installed in the following locations:
AREA
SMOKE ALARM
CO ALARM
Outside of each separate sleeping area in the immediate vicinity of the
bedroom(s)
X
X
On every level of a dwelling unit including basements
X
X
Within each sleeping room
X
Carbon Monoxide alarms are not required in dwellings which do not contain fuel -burning appliances and that
do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with
CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal.
Power Supply: In dwelling units with no commercial power supply, alarm(s) may be solely battery operated.
In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do
not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl
space. Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2. An electrical permit is required for
alarms which must be connected to the building wiring.
As owner of the above -referenced property,, I hereby certify that the alarm(s) referenced above has/have been
installed in accordance with the manufacturer's instructions and in compliance with the California,Building
and California Residential, Codes. The alarms have been tested and are operational,, as of the datel sighed
below.
t have read and agree, to comply with the terms and conditions of this statement
................... `. bat ". .
Sinafuse—� ......._.. ......... ...._.... ......... ..... Lra�.......................................a-fe ,
"=� L F
i "
WATER -CONSERVING PLUMBING FIXTURES f
OWNER CERTIFICATE OF COMPLIANCE
COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION
CUPERTINO I I0300 TORRE AVENUE ® CUPERTINO, CA 95014-3255
408) 777-3228 • FAX (408) 777-3333 building(a)cuQertino.ora yy
Owner Name' i 4 Permit No,'iBaD
6— I
Address'
v
1. Is your real property a registered historical site?
❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form.
t ZNo Go to Question 2.
2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its
plumbing, installation of water -conserving plumbing fixtures is not technically_ feasible?
❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply:
❑ The licensed plumber's certification has been provided to the Building Division.
Skip the rest of the form and sign bottom of farm.
0 L;�-No Go to Question 3.
3. Is water service permanently disconnected for your building? .
❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form.
kO-No Go to Question 4.
4. Is your real property built and available for use or occupancy on or before January 1, 1994?
No My real property is built and available for use or occupancy after January 1, 1994.
Civil Code Sections 1101.1 through .1101.8 do not apply. Skip the rest of the form and sign bottom of form.
PYes My real property is built and available for use or occupancy on or before January 1, 1994.
Civil Code Sections 1101.1 through 1101.8 apply. Check one of the three following statements and sign
bottom of form..
5. Please check ONE of the following:
91:�My property is a single-family residential real property. See Civil Code Section 1101.4.
On and after January 1, 2014, building alterations or improvements shall require all non -compliant plumbing fixtures
to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non-
compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless of whether
property undergoes alterations or improvements).
D My property is a multifamily residential real property. See Civil Code Section 1101.5..
On and after January 1, 2014, specified building alterations or improvements shall require non- compliant
plumbing fixtures to be replaced with water -conserving plumbing fixtures.
On or before January 1, 2019, all non -compliant plumbing fixtures shall be replaced with water -
conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or
improvements).
My property is a commercial real property. See Civil Code Section 1101.5.
On and after January 1, 2014, specified building alterations or improvements shall require non- compliant
plumbing fixtures to be replaced with water -conserving plumbing fixtures.
On or before January 1, 2019, all non -compliant plumbing fixtures shall be replaced with water- conserving
plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements).
I, as the owner or owner's agent of this property, certify under penalty of perjury that non -compliant plumbing fixtures will be
replaced prior to date specified above with water -conserving plumbing fixtures in accordance with Civil Code Sections 1101.1
through 1101.8, the current California Plumbing Code and California Green Building Standards Code, and manufacturer's
installation requirements, and that the water_conserving plumbing fixtures comply with the requirements as indicated in the
table on the following page.
Owner or Owner Agent's Signaturei `jam! � .,, A_ Date: I 42 le
Upon completing and signing this Certificate, please return it to the Building Division in order to final your building permit.
SB40 7 2015. doc revised 08126115