Loading...
B-2016-1782 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO:B-2016-1782 22219 HAMMOND WAY CUPERTINO,CA 95014-6576(342 58 008) CLEANFOCUS ENERGYINC SAN FRANCISCO,CA 94111 OWNER'S NAME: BISWAS SANJIT TRUSTEE&ET AL DATE ISSUED:04/18/2016 OWNER'S PHONE:408-300-4976 PHONE NO:(415)729-5575 LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO: License Class B Lic.#965327 Contractor CLEANFOCUS ENERGY INC Date 09/30/2017 X BLDG —ELECT —PLUMB I hereby affirm that I am licensed under the provisions of Chapter 9(commencing MECH•X RESIDENTIAL_COMMERCIAL with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. JOB DESCRIPTION: INSTALL(N)PV SOLAR ARRAY SYSTEM FLUSH-MOUNTED I hereby affirm under penalty of perjury one of the following two declarations: DIRECTLY TO THE ROOF-5.99 KW AND 19 PANELS 1. I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor'Area: Valuation:$23000.00 APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct.I agree to comply with all city and county ordinances APN Number: Occupancy Type: and state laws relating to building construction,and hereby authorize 342 58 008 representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save indemnify and keep harmless the City of Cupertino against liabilities,judgments,costs,and expenses which PERMIT EXPIRES IF WORD IS NOT STARTED may accrue against said City in consequence of the granting of this permit. WITHIN 180 DAYS OF PERMIT ISSUANCE OR Additionally,the applicant understands and will comply with all non-point source regulati s er.he Cupertino Municipal Code,Section 9.18. 180 DAYS FROM LAST CALLED INSPECTION. � f Signature Date 4/18/2016 Issued by:Alex Vallelunea Date:04/18/2016 OWNER-BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of the RE-ROOFS: following two reasons: All roofs shall be inspected prior to any roofing material being installed.If a roof is 1. I,as owner of the property,or my employees with wages as their sole installed without first obtaining an inspection,I agree to remove all new materials for compensation,will do the work,and the structure is not intended or offered for inspection. sale(Sec.7044,Business&Professions Code) 2. I,as owner of the property,am exclusively contracting with licensed Signature of,Applicant: contractors to construct the project(Sec.7044,Business&Professions Code). Date:4/18/2016 I hereby affirm under penalty of perjury one of the following three declarations: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER 1. I have and will maintain a Certificate of Consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. HAZARDOUS MATERIALS DISCLOSURE 2. I have and will maintain Worker's Compensation Insurance,as provided for by I have read the hazardous materials requirements under Chapter 6.95 of the Section 3700 of the Labor Code,for the performance of the work for which this California Health&Safety Code,Sections 25505,25533,and 25534. I will permit is issued. maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the a. I certify that in the performance of the work for which this permit is issued,I Health&Safety Code,Section 25532(a)should I store or handle hazardous material. Additionally,should I use equipment or devices which emit hazardous shall not employ any person in any manner so as to become subject to the air contaminants as defined by the Bay Area Air Quality Management District I Worker's Compensation laws of California. If,after making this certificate of will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and exemption,I become subject to the Worker's Compensation provisions of the the Health&Safety Code,Se s 255 5,25533,and 25534. Labor Code,I must forthwith comply with such provisions or this permit shall be deemed revoked. y Owner or authorized agent: APPLICANT CERTIFICATION Date:4/18/2016 I certify that'l have read this application and state that the above information is CONSTRUCT ON LENDINL AGENCY correct.I agree to comply with all city and county ordinances and state laws I hereby affirm that there is a construction lending agency for the performance relating to building construction,and hereby authorize representatives of this city of work's fo'r which this permit is issued(Sec.3097,Civ C.) to enter upon the above mentioned property for inspection purposes. (We)agree Lender's Name to save indemnify and keep harmless the City of Cupertino against liabilities, judgments,costs,and expenses which may accrue against said City in Lender's Address consequence of the granting of this permit. Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal ARCHITECT'S DECLARATION Code,Section 9.18. 1 understand my plans shall be used as public records. Licensed Signature Date 4/18/2016 Professional ALTERNATIVE ENERGY PERMIT APPLICATION A COMMUNITY DEVELOPMENT DEPARTIOENT • BUILDING DIVISION 10300 TORRE AVENUE. CUPERTINO, CA 9501 -3255 (408)777-3228 • FAX(408)777-3333• buildinan.cupertino.org CUPERTINO 13 PROJECT ADDRESS � � � INR J OWIiRNAA4Epmsft�,�+ ��5 P \ [ E-MAIL w 1w STREET ADDRESS 2;z,2, 8I , P CITY, STAT I FAX CONTACT 1;Ah!EP) I ; l PH l� 7,-Xg --'7S— E 2` ^ e4K STREET AD CITY,STATE O' FAX J El cm,,R ❑ O1Y)BR-BUIIDER Ol1T_RkGtvT C01,'IR4Ci0R ❑COJ.iR4CT0 AGEK ❑ ARCl-=1-CT ❑ENGINEER ❑ DEVELOPER ❑ i_J AM CONTRACTOR N MO 6 LICE'-SE NUMBER ��4y� LICEI\'SE TYPE I BUS.LIC R ' o; OLI COl✓,PANY h. Ps,i`I +\cke'6 y/ I F?.X STREET ADDRESS,y,,,> � h /•_ CITY; PHON-- '5 ,,.,Q ARCMTECTicNGINMI �''J EER NP. E LCENSE IME BR BUS.LIC R P�,J COMPANY NAME E-M.AIL FAX STREET ADDRESS I CITY,STATE,ZIP PHO)\ USE OF ❑ SFD or Duplex ❑ Multi-Family PROJECT IN WILDLAND PROJECT IN STRUCTURE: ❑ Commercial URBAN INTERFACE AREA ❑ Yes 13NO FLOOD ZONE ❑ Yes ❑ No Y-SOLARPANELS ❑ ELECTRIC VEHICLE CHI4RGING STATION ❑ SOLAR WATER FaATING ❑ OTHER: FDR SOLAR PAA'ELS. NUMBER OF PANILS/UNITS: KILOWATTS(COMMIER TIAL ONLI�: TOTAL VALUATION: DESCRIPTION OF WORK ' v '5 *1 r-Av n p '- By my signature below,I certify to each of the following: I am the propery owvner or authorized agent to act on the.properly mvne-r's behalf. I have read this application and the information I hav -o id is Corr-- . I ve.re d the Description of WorJc and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating 1 onsClio I t ize representatives of Cupddrtino to enter the above-identified property for inspection purposes. S ignature ofApplicant/Agent: Date: �( 0 —,26I� SUPPLE'NdE TTAL INTFORMATION REQUIRED i _ OPFTCE'U�EONZY ° `' y `v 9�ER THECOUI�TER -2 Lim I ?c x t } S V L7 CT43�DARD _ S f _t J � ;A-A tv w I tjG.--Qv n kv-4-N A a-AlvL PE4pp_2011. ,oc revised 03/16/11 I * ` PROJECT DESCRIPTION: " VuvUa oy'n 19X315W ROOF MOUNTED SOLAR CLEA', FACT R PHOTOVOLTAIC MODULES ppEPARTMENT SYSTEM SIZE: 5.99 kW DC STC PROJECT SITE OMMUN1Tir � ARRAY AREA: 335.35 ft2 BUILDING DIVISION-CUP Clean Factor ��RVVED SHEET INDEX PV-1 SITE PLAN &VICINITY MAP • plans and specifications MU T be k7at PV-2 ROOF PLAN & PANELS Energy, Inc. Th��, t of p PV-3 ROOF ATTACHMENT DETAIL& =" 500 Sansome Street, Job 3 during construction. It is unlaw ul to make any ELEVATION PROFILE hanges or altemt;ons on same,or o doviate (' Suite 510, r roval from the B lid Official. PV-4 ELECTRIC LINE DIAGRAM '' " - therefrom,without app PV-5 WIRING CALCULATION r San Francisco, EXISTING ,anificatits SHALL N0 PV-6 PLACARDS \ CA 94111 Tho P- ..'raping 90f,.EXISTING d the violation Tel.: (415) 729-5575 be E:.d to perry BACKYAR PV-7 SPECIFICATION DETAIL �} RECEIVED ansa or State Law. PV-8 SPECIFICATION DETAIL Fax: (707) 477-5643 of ny provision PV-9 SPECIFICATION DETAIL �. 22219 Hammond Way www.cleanfocusenergy.col PV-10 SPECIFICATION DETAIL BY project name and address D'-,T Io I(� - 11 _ Prasenjit Biswas PER .IT NO .-. 22219 Hammond Way �Y � Cupertino OFFICEC CA 95014 . ...,,. ,.r (E) POOL CUPERTINO Building Departrnent 2 VICINITY MAP v ;n APR 82016 PV 1 SCALE: NTS ROOF#1 (19) LG ELECTRONICS: IEWED FOR CODE COMPLIANCE LG315N1C-G4 (315W) reviewed By: ARRAY LOCATION - (E)400A MAIN SERVICE PANEL (OUTSIDE OF THE HOUSE) P LQTPLANS CHECKED BY - EXISTING cn EXISTING DATE DRIVEWAY FRONTYARD PLANNING DEPT --- - - N�' C;UPERTINO r 3OVERNING CODES ;ALIFORNIA ELECTRIC CODE, 2013 EDITION (CEC) , ;ALIFORNIA RESIDENTIAL CODE, 2013 (CRC) R ; ALIFORNIA PLUMBING CODE, 2013 (CPC) HAMIVI ;ALIFORNIA BUILDING CODE, 2013 EDITION (CBC) OND WAY ,ALIFORNIA MECHANICAL CODE, 2013 (CMC) \RTICLE 690, NEC 2011 CODE BOOK -ITLE 24 RESIDENCE ENERGY EFFICIENCY STANDARDS ;AL-FIRE PHOTOVOLTAIC INSTALLATION GUIDELINES „ PLAN NORTH TITLE SHEET 1 SITE PLAN WITH ROOF PLAN 3 HOUSE PHOTO SITE PLAN &VICINITY MAP PV-1 SCALE: 1/32"=1'-0" PV-1 SCALE: NTS 11 1 PV-1 aUIai Ni wwvui�ai�sysLCi i i MC)DULE TYPE, DIMENSIONS & WEIGHT MODULE TYPE= LG ELECTRONICS: LG315N1 C-G4 (315W) CCS r,A!N FAC7Z R MODULE WEIGHT=37.48 LBS/17.0 KG. ENERGY MODULE DIMENSIONS =64.57"X 39.37"= 17.65 SF UNIT WEIGHT OF ARRAY=2.20 PSF Clean Factor ARRAY & ROOF #1 AREA CALC'S Energy, Inc. C. ARRAY AREA =335.35 ft . �, 500 Sansome Street, ROOF FACE AREA=6447.36 ftz. Suite 510, 335.35/6447.36=5% OF ROOF San Francisco, FACE AREA COVERED BY ARRAY CA 94111 ROOF DESCRIPTION Fax: (707)477-5643 COMP SHINGLES ROOFING ;— www.cleanfocusenergy.coi ROOF PITCH 230 project name and address ARRAY AZIMUTH 2670 RAFTERS 2"x6"SPACING tom'' O.C. — Prasenjit Biswas 22219 Hammond Way Cupertino w — CA 95014 N - h� RAFTERS 2"x6" @ 16"O.C. (19) LG ELECTRONICS: LG315N1C-G4 3' FIRE SETBACK (ROOF#1) \. MICRO-INVERTER ON EACH MODULE (50)ATTACHMENT POINTS @ 6' O.0 MAX — y (ROOF#1) IRONRIDGE XR100 SOLAR RAIL 4' EMT CONDUIT (E)400AMP MAIN — CUPERTINO SERVICE PANEL � I Building Department APR 18 20% 11.02 W-32° REVIEWED FOR CODE COMPLIANCE JUNCTION BOX COMMON TYPE Reviewed By'. NEMA 3R TYP. PLAN TITLE SHEET NORTH ROOF PLAN & 1 ROOF PLAN PANELS PV-2 SCALE:1/16"=1'-T PV-2 JVlpl FJIIVIVVVILpIV Jy JLVI11 CONCRETE TILE CLEfA H FACT v R ROOF ENERGY — PV MODULE Clean Factor Ener Inc. IRONRIDGE XR100 RAIL ��� 500 Sansome Street, �7�%� Suite 510, 4J San Francisco, 5/16" SS LAG BOLT MIN. — xsRyFTFRs@'s"o.� CA 94111 2.5" PENETRATION Tel.: (415) 729-5575 SEALED W/SIKAFLEX 1A \ Fax: (707)477-5643 - www.cleanfocusenergy.col project name and address \ Prasenjit Biswas QUICKSCREW TILE HOOK 22219 Hammond Way ATTACHMENT Cupertino CA 95014 1 ATTACHMENT DETAIL PV-3 SCALE: 1/2"=T-0" 3 6 1g" 1 16 3`L y Y\ , , 211x$11 2"x4'1 CUPERTINO o ' Building Department N APR 18 2016 SIN o ' REVIEWED FOR CODE COMPLIANCE T co Revlewea By. TITLE SHEET 2 SIDE SECTION ATTACHMENT DETAIL& ELEVATION PROFILE PV-3 SCALE: NTS PV-3 aviai Ni iUwVURCU ,ayaMa1 i i SOLAR ARRAY (5.99 kWstc) (19) LG ELECTRONICS: LG315N1 C-G4 (315W) MODULES TOTAL FACTt R (10) MODULES CONNECTED IN BRANCH CIRCUIT#1 ENERGY 9 MODULES CONNECTED IN BRANCH CIRCUIT#2 MICRO-INVERTER ENPHASE ( ) SOLAR MODULE S280-60-LL-2/5-US 240VAC, 1.13A 97% Clean Factor CEC-WEIGHTED EFF NEMA, UL LISTED ENPHASE Energy, Inc. END CAP - - - 500 Sansome Street, Suite 510 San Francisco, CA 94111 -- ----------------------- ------ Tel.: (415) 729-5575 MICRO-INVERTER ENPHASE CUPERTINO Fax: (707)477-5643 SOLAR MODULE S280-60-LL-2/5-US 240VAC, 1.1 97 Building Department www.cleanfocusenergy.col ENPHASE BRANCH CEC-WEIGHTED EFF NEMA, U project name and address CIRCUIT CABLE ENPHASE APR 182016 I Prasenjit Biswas END CAP REVIEWED FOR CODE COMPLIANCE 22219 Hammond Way I ----------------------- G- Reviewed By:G G G G G G G G �`i Cupertino � I -- - -- - � - - -- -- -- -- -- -- -- - - -- CA 95014 I I I I r- -------------------- G _---- G ----- G --- G ---_- G ----- G ----- G ----- G ----- G ENPHASE ENERGY: S280-60-LL-2/5-US (240V) I 'MPPT RANGE:27-37V MAX INPUT DC VOLTAGE:48V NOMINAL VOLTAGE/RANGE: 235-365V (4)#10 AWG PV WIRE NOMINAL OUTPUT CURENT: 1.13A j (2)#8 AWG PV WIRE TO UTILITY GRID CEC EFFICIENCY: 97.0% GND IN Y2" EMT MODULE: LG ELECTRONICS: LG315N1C-G4 L1 N (315W) BI-DIRECTIONAL CEC PTC Rating: 287AW o UTILITY METER Voc=40.6V Vmp=33.2V N L L1 N L1 JUNCTION BOX 1-PHASE, 240 V Isc= 10.02A Imp=9.50A COMMONTL1 N Pmax: 315W � I TYPE NEMA 3R L1 N MATERIAL LIST LG ELECTRONICS: LG315N1C-G4 MODULES 19 G N L1 G N L1 MICRO-INVERTER ENPHASE: 19 S280-60-LL-2/5-US (240V) I I MAIN SERVICE ORION FLAT TILE HOOK ATTACHMENTS 28 L1 L1 DISCONNECT 240V, IRONRIDGE XR100 RAIL 101' 2 200A MID CLAMPS 34 I I N N A 2P END CLAMPS 12 L115 ENGAGE CABLE 38' MAIN SERVICE PANEL, I I N —AlN 4 SIEMENS MC3040M622B ' EMT CONDUIT 28' 15A/2P LF1l L1240 VAC, 400A JUNCTION BOX COMMON TYPE NEMA 3R 1 2 N N SOLAR LOAD CENTER 100AMP 1 I � 1 L----------J------------ ------------------------------------------I N 30AMP 2-POLE CIRCUIT BREAKER G — , GROUND ROD 1 (6)#10 AWG THWN-2 INTERCONNECTION I 2 #8 AWG THWN-2 120%RULE-NEC 690.64(D)(2) I I CABLE DROP 17 ( ) L-------------- I GND IN%4" EMT UTILITY FEED+SOLAR BACKFEED BRANCH TERMINATOR 2 200.0 A+30A=230A SEALING CAP 2 TITLE SHEET BUSS RATING x 120% 1 LEC. LINE ELECTRICAL LINE DRAWING 400.0 Ax 120%=480A EXISTING GROUNDING DIAGRAM ELECTRODE SYSTEM PV-4 SCALE: N.T.S. P - aviai Fn ivivvvnait'oyatau i MAX PV VOLTAGE & CURRENT CALC'S: INTERNAL VOLTAGE RISE WITHIN THE ENGAGE CABLES: CLUEFACT R ENERGY BRANCH CIRCUIT MAX VOLTAGE: PER ENPHASE TABLE: 240.84VAC INTERNAL VOLTAGE %Rise FOR#OF INVERTERS Clean Factor MAX PV CURRENT PER NEC 690.8(A)(3) BRANCH CIRCUIT OF 10 PORTRAIT = 0.35% 1.25 X MAX AC OUTPUT CURRENT X#OF INVERTERS PER STRING BRANCH CIRCUIT OF 9 PORTRAIT = 0.48% Energy, Inc. 1.25 X1.13 X 10 = 14.13 A 500 Sansome Street, VOLTAGE RISE FROM THE ARRAY-MOUNTED Suite 510, San Francisco, AC JUNCTION BOX TO LOAD CENTER: CA 94111 AC CONDUCTOR AMPACITY CALCULATIONS: Tel.: (415) 729-5575 ARRAY- 1: Fax: (707)477-5643 FROM ROOF TOP JUNCTION BOX TO SUBPANELwww.cleanfocusenergy.col VRise=(AMPS/INVERTER)*(#OF INVERTERS)*(1MRE RESISTANCEf?fft)*(1MRE LENGTH*2) AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT VRise = (1.13A)*(10 OF INVERTER)*(0.00129 0/ft)*(50ft x 2) project name and address PER NEC 310.15(B)(2)(c):+22° VRise = 1.46V Prasenjit Biswas EXPECTED WIRE TEMP (°C):41' +22° %VRise= (VRISE V)/240V=% VRise TEMP CORRECTION PER TABLE 310.16: 0.58 %VRise= 1.46V/240V*(100%)= 0.61%VRise 22219 Hammond Way #OF CURRENT CARRYING CONDUCTORS: 4 Cupertino CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a): 0.80 ARRAY-2: CA 95014 CIRCUIT CONDUCTOR SIZE: 10 AWG VRise=(AMPSANVERTER)*(#OF INVERTERS CIRCUIT CONDUCTOR AMPACITY: 40 A ) (WIRE RESISTANCEf?/ft) (1MRE LENGTH*2) VRise= (1.13A)*(9 OF INVERTER)*(0.00129 0/ft)*(50ft x 2) REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B): VRise= 1.31V%VRise-(VRISE V)/240V- %VRise 1.25 X 1.13 X 10= 14.13 A %VRise= 1.31V/240V*(100%)= 0.55%VRise DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 TEMP CORR. PER NEC TABLE 310.16 X VOLTAGE RISE FROM THE LOAD CENTER TO UTILITY: CONDUIT FILL CORR. PER NEC 310.15(B)(2)(a)X CIRCUIT CONDUCTOR AMPACITY= VRise=(SUM OF ALL STRING CURRENTS)*(WIRE RESISTANCE fyft)*(WIRE LENGTH*2) 0.58 X 0.80 X 40 = 18.56 A VRise = (21.47A)* (0.00129 f0/ft)*(1 Oft x 2) VRise = 0.55V %VRise= 0.55V/240V*(100%)=0.23%VRise AC CONDUCTOR AMPACITY CALCULATIONS: CUPERTINO SUMMARY OF CALCULATIONS Building Department FROM SUBPANELTO UTILITY FOR 240VAC APPLICATIONS: APR 18 2016 EXPECTED WIRE TEMP (°C): 41° TEMP CORRECTION PER NEC TABLE 310.16: 0.87 REVIEVVED FOR CODE COMPLIANCE CIRCUIT CONDUCTOR SIZE: 10 AWG VRise=(SUM OF ALL INTERNAL VOLTAGE%Rise FOR EA. BRANCH) �� CIRCUIT CONDUCTOR AMPACITY:40 A +(SUM OF ALL%VRise JUNCTION BOX TO LOAD CENTER FOR EA.ARRAY) Reviewed By: #OF CURRENT CARRYING CONDUCTORS: 3 +(%VRise FROM LOAD CENTER TO UTILITY) CONDUIT FILL PER NEC 310.15(B)(2)(a): 1 0.35+0.61 +0.23= 1.19% REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B): 0.48+0.55+0.23= 1.26% 1.25 X MAX AC OUTPUT X#OF INVERTERS 1.25 X 1.13 X 19=26.84 A 119% <2% DERATED AMPACITY OF CIRCUIT CONDUCTORS PER NEC TABLE 310.16: 1.26% <2% TEMP CORR. PER NEC 310.16 X SUMMARY%SHOULD BE<2%TO BE OKAY CONDUIT FILL CORR. PER NEC 310.15(B)(2)(a)X CIRCUIT CONDUCTOR AMPACITY= 0.87X1 X40=34.8A TITLE SHEET WIRING CALCULATION PV-5 aviai Ni wwvvnan,ayaLUJ i i OGROUND-FAULT DETECTION AND �� bs� INTERUPTION; O TO BE INSTALLED ON THE FACE OF THE FACTr;>-R TO BE INSTALLED AT INVERTER PER NEC SERVICE METER PANEL PER ENERGY 2008 690.5 (C) NEC 2008 705.10 Clean Factor WARNING ELECTRIC SHOCK HAZARD IF A CAUTION: GROUND FAULT IS Energy, Inc. INDICATED,NORMALLY GROUNDED POWER TO THIS BUILDING IS ALSO SUPPLIED FROM 500 Sansome Street, CONDUCTORS MAY BE THE FOLLOWING SOURCES WITH DISCONNECTS Suite 510, UNGROUNDED AND ENERGIZED LOCATED AS SHOWN San Francisco, DISCONNECTION MEANS; TO BE AT:® METER AND MAIN SERVICE CA 94111 INSTALLED AT ALL AC AND DC AC DISCONNECT Tel.: (415)729-5575 DISCONNECTS RESPECTIVELY PER NEC DC DISCONNECT Fax: (707)477-5643 2008 90.14(C)(2) INVERTER www.cleanfocusener gy.coi project name and address SOLAR AC DISCONNECT Prasenjit Biswas 22219 Hammond Way HAMMO�D WAY Cupertino CA 95014 ODISCONNECTING MEANS MAY BE ENERGIZED IN MARKING CONTENT AND FORMAT THE OPEN POSITION;TO BE INSTALLED AT • RED BACKGROUND DISCONNECTING MEANS WHITE LETTERING PER NEC 2008 690.17 MINIMUM 3/8" LETTER HEIGHT • ALL CAPITAL LETTERS WARNING • ARIAL OR SIMILAR FONT, NON-BOLD ELECTRIC SHOCK HAZARD.DO NOT REFLECTIVE WEATHER RESISTANT TOUCH TERMINALS.TERMINALS ON MATERIAL SUITABLE FOR THE BOTH THE LINE AND LOAD SIDE ENVIRONMENT(DURABLE ADHESIVE MAY BE ENERGIZED IN THE OPEN MATERIALS MUST MEET THIS POSITION. REQUIREMENT) • TO BE ATTACHED USING POP-RIVETS OINVERTER OUTPUT CONNECTION TO BE INSTALLED AT MAIN SERVICE PANEL PER NEC 2008 690.64 (BCUPERTINO)(7) � Building Department WARNING APR 1 2016 INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE REVIEWED FOR CODE COMPLIANCE Reviewed By: OMARKING SHOULD BE PLACED ON ALL INTERIOR AND EXTERIOR PV CONDUIT, RACEWAYS, ENCLOSURES, AND CABLE ASSEMBLIES, EVERY 10 FEET, AT TURNS AND ABOVE AND/OR BELOW PENETRATIONS AND ALL PV COMBINER AND JUNCTION BOXES. CAUTION: SOLAR CIRCUIT OTO BE LOCATED AT MAIN SERVICE PANEL: TITLE SHEET CAUTION: SOLAR ELECTRIC SYSTEM PLACARDS CONNECTED PV-6 .-� OUI C3 f•JI IULU VU LCIIV-YOM;I I I P-1 FACT>= R ENERGY CUPERTIN® Clean Factor Building DePartrnent Y: -ra APR 1 6 2016 Energy, Inc. � �,.� 500 Sansome Street, LGN REViEVVED FOR CODE COMPLIANCE Suite 510, (OLIG Innovation • San Francisco, Lifers Goad Better Reviewed By: CA 94111 Mechanical Properties Electrical Properties(STC*) Tel.: (415) 729-5575 Celts 6 x 19 Module Type 315W-- Fax: (707)477-5643 Celt Vundor LG MNP Voltage(Vmpp) 33.2 www.cleanfocusener col Cell Type iVcnucryst=li:ro_/N-ryes MPP Current(Impp) 9 50 gy Cell Dimensions 156.75 x 15675 rnm/6mches Open Circuit Voltage(Vnc) 406 of 13u4bar 1210 x 1 W0 x"O hal name and address j(0 Silo[ ❑ICllit Current(Isc) 10-02 project Dimcrsiaus(LxWxH) 1640x1000x4Umm 0.iadulaEffidiatiy(9G) let Prasenjit Biswas Frnt Load 64 57x39 37 x 1 51* opecuu,g Temperature('C) -40-0 o6DOP,Pa/125 psF Maximmn 5/stern Voltage(V) 1 fJUO Rev Load 5400 Pa/117 P51 0 Maximmn Series fuse Raine A 20 22219 Hammond Way Wright 00±0.5 kg/37 48_.1 1 1hs Power Totenrre('/.,) 0-r3 ConnecturT UC4,VCaC -ssOiides 1yrr ,,__ -•_�1 Cupertino Type F >tC t_r.rtlin i,+c=sa:4=nl 1, v Wi.-O Vvar.�:tYJue rorpu,!r:re JS M1N 1 lurctianfiox IP 67wrth38 =ss0ixes ^nor nr.,mcs,,rw,,�uu,nr,,,1�J;nJet•.,.m�e:tyh9E�e.:.m<--,t,csu�.r c:mccns•. CA 95014 •hietyyim!CwvxhrtloduSe 9Clrkrcya:1001N/m'to rdslu,to-1000whi s-20% Length of Cables 2 x 1,720 mm/2 x 73 37 inch - Grass_ Anodized i ed Alum,nu Te,��;ered Glass Frame MrhTrais Alum, Electrical Properties(NOCT*) Certifications and Wanr my Module Type '315 w Maximum Power(Nnax) 290 CettiNratldts IEC 6121 5,IEC 6 1730-11-2 MVP Vottaye(Vmpp) '30,4 �,� 5eol� IEC 62716(Amrn :na'rest) MPP Current(Impp) 7S8 `fid/ �� IEC 617:31(SaItVlistCorrosimTest) open Circuit Vottage(Voc) 37.6 ISO 9001 short Ci,c'uit Current(Isc) 8 08 UL 1703 •rv�_r{n:,-:,,::_t<r.,rslt..a1..:�..r=,,:,�7,1 ,..�_:.w:res...:b..c�:�t.,.,�a:,•c,v�rr,4,...J,,•�_ Modute Fire Perforuiarice.(USA) Tyce 2(UL 1723) Fire Ratiny(fon-CANADA) ClassC(1JL(:/L"20 C1 703) Dimensions(mm/in) Product Warralli 12 years 0 LG's newmodule,LG NeON"I 2,adopts Cello technology- output Wal"my of Pn,ax Lrearwarranty'10. Cello technology replaces 3 busbarswith 12 thin wires APFROVEOPROWCr ,tl. } ,c5.s}l Arrc2 inJ Ys'v 0fif7 vm..l�e ra::3�.n.11E=syr lyes-;. to enhance power output and reliability.LG NeCINT""2 �/ 60 Celtdernonstrates LG's efforts to increase customer's values D E e m ` �' Temperature Characteristics beyond efficiency.it features enhanced warranty,durability, Norr 46 s 3°c EE -1 fl ?"SCI n aseicizts Performance under real environment,and aesthetic Pmpp p 38 VVIC design suitable for roofs, Voc _0 28 VrC Isc 0.03"VVIC Characteristic Curves A; Enhanced Performance Warranty iii m, High Power Output psi® �tfi't N". - I. .na - o a LG,VeON 2 has an enhanced performance Nrarranry. _311 3_-, Compared with Frevtous moCels,the LG NeON �2 .j • + x 1 The annual degradation has fallen from-0.7'%/^r to ;lea3''i9� figs been designed to niflcantl eit)larlce its output a 1 sift g / �ii)31s`i� 9 � Y °� raur jam- +i--- -0.6%/yr_Even after 25 year,,the cell guarantees 24Vp tt g efrxiencysthetebymaldngitefficientevertinGmi�dspate. more output,than the previous LG NeON-modules ow Aesthetic Roof Outstanding Durability o)aa�' n■ N �1"'al om oar 1ac� )aW .a® _SCC sa ec <s:a mx rzv _ ]1 u V NeON' 2 has been desi ned with aesd,eacs in mend, o I With Its newt reinforced frame design,LG has extended s-ii ai�,a a3 9 ate� ega9t Y 9 , :, �ae'r al!;:lam thinner.wires that appear all t}la tk at a.dstance �t31i°) ty J y ii j the tvarran of[he LG IVeON' 2 Fcr an'addinonal rs�da.f:s„ �,,.l:l,s;, t.a t The product may help Increase the value of 2 years Additionally LG NeONr^2 can endure a front ; a pr^Ferty with its modern design load up to 6000 Pa,and a rear Nati up to 5400 Pa. 9PBetter Performance on a Sunny Day Double-Sided Cell Structure LGNeONr"42how_performs better on sunny days thanks �- The rear of"he cell used in LG NeON'm2wdlccntnbuteto r ---- to its improved temperature oxffiaency. Ilii i.iill generatran,yEtLice the f ont:the rghtbeam mfiectedfrom ----- ------- s - �'c7 �i36 iI3 5ilir' oil_ - - the rear of the module is reabsorbed to generate a great t n arnaunt of ad ditional pcwer ?a -is o .s so .. •�np ls:.in.=te trsui[rn<c::c�:rtc:ru:Gcxly'.Tu:riJ.m lnxcl ,VjlthAmerrza Sc{_-.r-usires;Te3.•n PradurSsprxifloitlmaare svbjeRto dwrge vritlnait notice ��y, 'e7 .l5"SFRI About LG Electronics LIM Goad ,r-^7 Sy:;nn r\ie, y(ewx7 iris,\11:e7Ei'? � � EI ra,ics ns r�Icoal plaj•er wh:+ha;lice•^:ar-nor-trt_m Espan.i- �c.-ap,1c,[y,--"wd cn s.lar erer::Y b1:s:ness as iu fuz—g-m",ci=;—we mbvie-c.:a s:i�;r r�ri�J sour*e*ere-rc•p.rg.; , Cccyrlsh,.'_1>'il�LS ec:rcn:ts A7 rirr:[5 re-;erveu Ima�avan for aBenvLi(e . - t r .min L:x!ru-x gs...ur�i{�e^_:nn B1/`J4/�71� !` 1985,supported try LG Graup's rich o�erienm n semi-mndurtor,LCD,cbirnisbyt and rrshrials i�at}e wemo:asfulry rekm dthe first MumX*sedes totkariorratin 2010,whid,xvs mTortedto 32 •,vin r I usa e>-1 �ure.s�,n;i<•f„I;ornng 2yr—,thereafter 1:20 13,LG Uet',•L"";prev: :iy irsvr1 AML'—x9\'F•JV)-.,=e'•�r:.•rs cl..r Award;wh.hprc<•=?LG st1+=:ca..rr�r ovn�v to n:n me rd_5r..y all. TITLE SHEET SPECIFICATION DETAIL PV-7 r t aUrar N'rvwvvnau.,ayaUCr t t FAC T�� �R ENERGY CUPERTIN® Clean Factor _ Enphase S280 M icroinverter//DATA E n e rg y� Inc. i3uiidiflg Department INPUT DATA(DC) S280-60-LL-2-US,S280.60-LL-5-US Enpl�asefViicroinverters - � 500 Sansome Street, APR 18 2016 Commonly used module pairings' 235 W-365 W -'.( Suite 510, EnphaseS280 Maximum input DC voltage 48V REVIEWED FOR CODE COMPLIANCE Peak power tracking voltage San Francisco, 27 V-37 v CA 94111 eviewed By: Operating range 1 s v-48 v Tel.: (415) 729-5575 Min/Max start voltage' 22 V/48 V Fax: (707)477-5643 Max DC short circuit current 15 A www.cleanfocusenergy.col OUTPUT DATA(AC) 206 VAC 240 VAC project name and address Peak output power 280 VA 280 VA Prasenjit Biswas Maximum continuous power 270 VA 270 VA 22219 Hammond Way # Nominal voltage/range' 208 V/'183-229 V 240 V/211-264 V Cupertino Nominal output current 1.30 A 1.13 A - - -- - - - -- - - - CA 95014 _ Nominal frequency/range 60/57-61 Hz 60/57-61.Hz Extended frequency range. 57-63 Hz 57-63 Hz %; j ! Power factor at rated power 1.0 1.0 r I Maximum units per 20 A branch circuit 21 (three phase,balanced) 14(single phase) Maximum output fault current 663 mA rms,.100 ms 663 mA,100 ms Power factor(adjustable) 1/0.7 leading...0.7 lagging 1 /0.7 leading...0.7 lagging EFFICIENCY 206 Vac 240 Vac CEO weighted efficiency 96:5'% . 97.0 Peak inverter efficiency 96.8% 97.3 IN. MECHANICAL DATA Designed for high-powered, 60-cell modules, the advanced grid-ready Enphase 5280 MicroinverterT' is built on the fifth-generation platform and achieves the highest efficiency for module-level power electronics along Ambient temperature,range, -40°Cto+6510 with cost per watt reduction. With its all-AC approach, the 5280 simplifies design and installation for Connector type S280-60-LL-2-U8:MC4 280 VA 5280-60-1-L-5-US:Amphenol H4 installations, and delivers optimal-energy harvest.The S280 is compatible with storage systems, including Dimensions(WxHxD} 172 mrn x 175 mm x 35.mm(without:bracket) battery management systems. weight 1.8 kg(4 lbs) Cooling Natural-convection-.No ians The Enphase S280 integrates seamlessly the Enphase Envoy-ST11 communications gateway, and Enphase Enclosure environmental rating Outdoor-NEMA 6 Enlighten"monitoring and analysis software. FEATURES Compatibility 60-cell PV modules PRODUCTIVE SIMPLE AND RELIABLE ADVANCED GRID READY communication Power line Integrated,ground' The DC circuit meets the requirements for ungrounded PV arrays in -Optimized for higher-power, -No GEC needed for microinverter -Complies with fixed power factor, NEC 690.35.Equipment ground is provided in the Engage Cable.No additional 60.-cell modules -No DC design or string calculation voltage and frequency ride-through GEC or-ground is required.GroundLfauft protection(GFP)is integrated Into the m i croinve iter. -Maximizes energy required requirements Monitoring Enlighten Manager and MyEnlighten monitoring options production -More than 1 million hours of testing -Remote updating to,respond to - - - -Minimizes impact of shading, -IndCompliance UL1741/IEEE1547,FGG Part 15 Class B,ustry-leading warranty, changing grid requirements CAN/CSA 022.2 NO.0-M91,0;4-04,and 107.1-01 dust, and debris up to 25 years -Configurable for variable grid profiles like Hawaiian Electric Company 1.Suggestion only,inverter self limits DC inputs. (HECO)Rule 14H, California Rule 21 2.Nominal voltage range can be extended beyond nominal if required by the utility. enphase- SP.® To learn more.about Enphase Microinverter technology, r enphase� E N E R G Y C Us visit enphase.com L E N E R G Y 0 2015 Enphase Energy.All rights reserved.All trademarks or brands in this document are registered by their respective ov+ner. M Kr-00107 Rev 2.0 TITLE SHEET SPECIFICATION DETAIL PV-8 -Z)UICII YINAL)VURCM,--DyZ)Lt::1 I I ' ENERGY F1\ IRONRIDGE Roof Mount System ARails Clean Fact®r XR10 Rail XR100 Rail XR1000 Rail Internal Splices Energy, Inc. 500 Sansome Street, Suite 510, X San Francisco, CA 94111 Tel.: (415) 729-5575 Fax: (707)477-5643 A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices www.cleanfocusenergy.coi for regions without snow. solar mounting rail. rail for commercial projects. for seamless connections. 6'spanning capability - 8'spanning capability 12'spanning capability - Self-tapping screws project name and address Moderate load capability • Heavy load capability Extreme load capability Varying versions for rails Prasenjit Biswas Clear anodized finish Clear&black anod.finish Clear anodized finish Grounding Straps offered 0 22219 Hammond Way �,A Cupertino Attachments CA 95014 FlashFoot Slotted L-Feet Standoffs Tilt Legs w Q Anchor,flash, and mount Drop-in design for rapid rail Raise flush or tilted Tilt assembly to desired with all-in-one attachments. attachment. systems to various heights. angle, up to 45 degrees. AP Ships with all hardware - High-friction serrated face - Works with vent flashing - Attaches directly to rail IBC&IRC compliant - Heavy-duty profile shape . Ships pre-assembled - Ships with all hardware FOR CODE Certified with XR Rails - Clear&black anod.finish . Lengths from 3"to 9" - Fixed and adjustable Built- for soiar's toucj;-iast roofs. Wed BY' Clamps & Grounding lronRldge builds the strongest roof mounting system in solar. Every componeMYS83 been tested to the limit and proven in extreme environments. End Clamps Grounding Mid Clamps (B T-Bolt Grounding Lugs (j) Accessories Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and I � is also why our products are fully certified, code compliant and backed by a 20-year warranty. �-�r-j LL AI— Ce Strength Tested PE Certified All components evaluated for superior Pre-stamped engineering letters Slide in clamps and secure Attach and ground modules Ground system using the Provide a finished and structural performance. available in most states. modules at ends of rails. in the middle of the rail. rail's top slot. organized look for rails. • Mill finish &black anod. - Parallel bonding T-bolt No clips or washers - Snap-in Wire Clips • Sizes from 1.22"to 2.3" . Reusable up to 10 times Eliminates pre-drilling - Perfected End Caps Complete Assembly Design Software - Optional Under Clamps - Mill &black stainless Easy top-slot mounting - UV-protected polymer End-to-end solution provides G E3±6 Online tool generates a complete bill L Free ReSOUrces L attachment, mounting, and grounding. of materials in minutes. Design Assistant NABCEP Certified Training <1 Integrated Grounding 20 Year Warranty Go from rough layout to fully Earn free continuing education credits, engineered system. For free. while learning more about our systems. UL 2703 system eliminates separate Twice the protection offered by to ironFlidge.corn/rrn Go to lronRidge.com./training Go 7 module grounding components. competitors. TITLE SHEET SPECIFICATION DETAIL PV_9 0WIC11 F1 1UL%JVU1LC31L,ay OL­11 C L LH,431,N, FA C T cZD R ENERGY Clean Factor Part 0 Box Quantity Screw Size 17649 20:HbQlks- Not'Ind-uded D Energy, Inc. 17541 1-Hook Not Included., 500 Sansome Street, 17542 20'Hooks 'Hooks&40 Screws #14 x 3"'. Suite 510, 17543 Hook&2 Screws _#140" 0M San Francisco, 17608-4.2-OHooks&40:8dews .5116'`x,3" CA 94111 17609 1 Hook,!&2 Screws 5116"0" Tel.: (415) 729-5575 Type 304 Stainless Steel Fax: (707) 477-5643 For-Side.MbUnt Rails www.cleanfocusenergy.coi g. project name and address Prasenjit Biswas 22219 Hammond Way Cupertino CA 95014 Rev2 IL—eftir Descriptid,n Size/Length A..- -106uridrid 80ew Holes ft* El� Rzd!Slot Size 1_16rft1y1­x,46rhm CLen g6­of Roof Hook-- 286mm ...................................... ......................................... Q RAiI.`Hdi'dht,'Frorn Fir'i8dd R0.0-f 70mm- 1-08mm R E_ Thickness 5M M DM., CUPERTINO 5mm 120mm Building Departmen —1t .1 G. APR 182016 B REVIEWED FOR CODE COMPLIANCE C Rail Slot Accepts 5/16°or-3!8"Bolts Reviewed By: 178mm f 2 D• Al 38MM 1 120* A E Use4ur#14'or:5/16'? 81.82mm Solar Mo nting Screws./ 1.30mm 44mm lbmm 5830 Las Positas Road, Livermore, California 94551 .13048 Airway Drive Rock Hill, South Carolina 29732 TITLE SHEET Phone: (844)-671-6045 1 fax. (000)-009-7975 1 www.soIarro.0fhook-..qqirh solarroofhook.com is a division of Quickscrews International Corp. SPECIFICATION DETAIL PV-10 I� F I SMOKE I CARBON MONOXIDE ALARMS nriA P05 41'orl 16 OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION 10300 TORRE AVENUE•CUPERTINO,CA 95014-3255 (408)777-3228• FAX(408)777-3333• building(ftupertino.or4 WOO 6-1W HAOVYtNo mal SyQ0 I&Iff-MA_041W&f 3 3 IAl l x I I=Jm cv V ? a Tbu, c r PURPOSE Tlis affidavit is a self-certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R314,2013 CBC Sections 420.6 and 907.2.11.2 where no interior access.for inspections are required. GENERAL INFORMATION Existing single-family and multi-family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions,alterations,or repairs to existing dwelling units exceeds $1000.001 CRC Section R314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations: AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of the X X bedroom(s) On ever_: level of a dwelling unit including basements X X Within each sleeping room X Carbon Monoxide alarms are not required in dwellings which do not contain fuel-burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. Power Supply: In dwelling units with no commercial power supply,alarm(s)may be solely battery operated. In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means-of attic,basement or crawl space-.Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2.An electrical permit is required for alarms which must be connected to the building wiring. As owner of the above-referenced property,I hereby certify that the alarm(s)referenced above has/have been installed in accordance with the manufacturer's instructions and in compliance with the California,Building. and Cahfon is Residential Codes. The alarms,have been tested and are operational,as of the date signed below,. l have read and a ree to com1, withthe terms , conditions of this statement a c�"If inafrtre ...,...... ....................................................... j ;Si nafu€e.r. ....--------------------------------Uc ,...,.. :Dafe .............. FINa� WATER-CONSERVING PLUMBING FIXTURESP06 , OWNER CERTIFICATE OF COMPLIANCE COMMUNITYDEVELOPMENT DEPARTMENT•BUILDING DIVISION CUPERTINo 10300TORRE AVENUE•CUPERTINO,CA 95014-3255 (4 )777-3228•F (408)7 3 33'•buildingCfcupertino.orci Owner Name . "f` �j jll� Permit No/r 6_ Address 1. Is your real property a registered historical site? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. D No Go to Question 2. 2. Does your real property have a licensed plumber certifying that,due to the age or configuration of the property or.its plumbing,installation of water-conserving plumbing fixtures is not technically feasible? Yes Civil Code Sections 1101.1 through 1101.8 do not apply. The licensed plumber's certification has been provided to the Building Division. Skip the rest of the form and sign bottom of form. No Go to Question 3. Li 3. Is water service permanently disconnected for your building? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. No Go to Question 4. 4. Is your real property built and available for use or occupancy on or before January 1, 1994? No My real property is built and available for use or occupancy after January 1, 1994. Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. J ❑ Yes My real property is built and available for use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101.8 apply. Check one of the three following statements and sign bottom of form.. 5. Please check ONE of the following: j J X My property is a single-family residential real property. See Civil Code Section 1101.4. On and after January 1, 2014,building alterations or improvements shall require all non-compliant plumbing fixtures to be replaced with water-conserving plumbing fixtures throughout the building.On or before January 1,2017,all non- compliant plumbing fixtures shall be replaced with water-conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements). ❑ My property is a multifamily residential real property. See Civil Code Section 1101.5. On and after January 1,2014,specified building alterations or improvements shall require non-compliant plumbing fixtures to be replaced with water-conserving plumbing fixtures. On or before January 1,2019,all non-compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building(regardless of whether property undergoes alterations or improvements). ❑ My property is a commercial real property. See Civil Code Section 1101.5. On and after January 1,2014,specified building alterations or improvements shall require non-compliant plumbing fixtures to be replaced with water-conserving plumbing fixtures. On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building(regardless of whether property undergoes alterations or improvements). 1,as the owner or owner's agent of this property,certify under penalty of perjury that non-compliant plumbing fixtures will be replaced prior to date specified above with water-conserving plumbing fixtures in accordance with Civil Code Sections 110 1.1 through 1101.8,the current California Plumbing Code and California Green Building Standards Code,and manufacturer's installation requirements,and that the water-conserving plum ' g fixtures comply with the requirements as indicated in the table on the following page. Owner or Owner Agent's Signature' Date: } ; Upon completing and signing this Certificate,please return it to the Building Division in order to final your building pe it. SB40720I5.docrevised 08/26/15