Loading...
B-2016-1791 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO:B-2016-1791 926 SEPTEMBER DR CUPERTINO,CA 95014-4143(362 14 006) SOLARCITY CORPORATION SAN MATEO,CA 94402 OWNER'S NAME: BISWAS DEBABRATA S AND MAITY SUTAPA DATE ISSUED:04/19/2016 OWNER'S PHONE:408-598-7545 PHONE NO:(650)963-4722 LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO: License Class CC10 Lic.#888104 Contractor SOLARCITY CORPORATION Date 12/31/2017 X BLDG _ELECT _PLUMB MECH X RESIDENTIAL_COMMERCIAL I hereby affirm that I am licensed under the provisions of Chapter 9(commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. JOB DESCRIPTION: INSTALL 7 ROOF TOP,FLUSH MOUNTED PV MODULES(1.82kW) I hereby affirm under penalty of perjury one of the following two declarations: i. I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. 2,®_ I have and will maintain Worker's Compensation Insurance,as provided for by I►Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$4500.00 APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct.I agree to comply with all city and county ordinances 62 Number: Occupancy Type: 3 and state laws relating to building construction,and hereby authorize 362 14 006 representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save indemnify and keep harmless the City of Cupertino against liabilities,judgments,costs,and expenses which PERMIT EXPIRES IF WORK IS NOT STARTED may accrue against said City in cons uence of the granting of this permit. WITHIN 180 DAYS OF PERMIT ISSUANCE OR Additionally,the applicant understan s and will comply with all non-point source regulations per the Cupertio Mu 'c' al Code,Section 9.18. 180 DAYS FROM LAST CALLED INSPECTION. ;s 7F Date 04/19/2016 Issued by:Alex Vallelunga Y �( t Date.04/19/2016 )6C OWNER-BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of the RE-ROOFS: following two reasons: All roofs shall be inspected prior to any roofing material being installed.If a roof is r. 1,as owner of the property,or my employees with wages as their sole installed without first obtaining an inspection,I agree to remove all new materials for compensation,will do the work,and the structure is not intended or offered for inspection. sale(Sec.7044,Business&Professions Code) 2. I,as owner of the property,am exclusively contracting with licensed Signature of Applicant: contractors to construct the project(See.7044,Business&Professions Code). Date:04/19/2016 1 hereby affirm under penalty of perjury one of the following three declarations: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER 1. I have and will maintain a Certificate of Consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. HAZARDOUS MATERIALS DISCLOSURE 2. I have and will maintain Worker's Compensation Insurance,as provided for by I have read the hazardous materials requirements under Chapter 6.95 of the Section 3700 of the Labor Code,for the performance of the work for which this California Health&Safety Code,Sections 25505,25533,and 25534. I will permit is issued. maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the 3. I certify that in the performance of the work for which this permit is issued,I Health&Safety Code,Section 25532(a)should I store or handle hazardous material. Additionally,should I use equipment or devices which emit hazardous shall not employ any person in any manner so as to become subject to the air contaminants as defined by the Bay Area Air Quality agement District I Worker's Compensation laws of California. If,after making this certificate of will maintain compliance with the Cupertino MunicipalY53apter 9.12 and exemption,I become subject to the Worker's Compensation provisions of the the Health&Safety Code,Sections 25505,25 34. Labor Code,I must forthwith comply with such provisions or this permit shall be deemed revoked. ()w„ ; n_. 26%autho 'zq genu APPLICANT CERTIFICATION Date 047 9 6 I certify that I have read this application and state that the above information is TR TI Di A E Y correct.I agree to comply with all city and county ordinances and state laws I hereby affirm that there is a construction lending agency for the performance relating to building construction,and hereby authorize representatives of this city of work's for which this permit is issued(Sec.3097,Civ C.) to enter upon the above mentioned property for inspection purposes. (We)agree Lender's Name to save indemnify and keep harmless the City of Cupertino against liabilities, judgments,costs,and expenses which may accrue against said City in Lender's Address consequence of the granting of this permit. Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal ARCHITECT'S DECLARATION Code,Section 9.18. I understand my plans shall be used as public records. Licensed Signature Date 04/19/2016 Professional --- - ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION 10300 TORRE AVENUE •CUPERTINO, CA 95014-3255 (408)777-3228•FAX(408)777-3333•building@cupertino.ora � CUPERTINO 1 \J G Lel� L PROJECT ADDRESSQ j C_ _,n b e / r° APN# /� _ 000 OWNER NAME L W V S W �J PHONE ZJry, 9_ ��r O �l E-MAIL STREET ADDRESS / C `^CNS y� CITY, STATE ZI^PV n Y��� V�. �_ c:Y !1© CONTACT NAME Marjan Javanmard PHONE 650.477.6430 E-MAIL mjavanmard@solarcity.com STREET ADDRESS 391 Foster City Blvd CITY,STATE,ZIP Foster City, CA 94404 FAX ❑OWNER ❑ OWNER-BUILDER ❑ OWNER AGENT ❑ CONTRACTOR 0 CONTRACTOR AGENT ❑ ARCHITECT ❑ENGINEER ❑ DEVELOPER ❑TENANT CONTRACTOR NAMESOIarCity Corporation LICE NSENUMBER888104 LICENSE TYPE C10 BUS.LIC#2S84-,q COMPANY NAMESOIarClty Corporation E-MAILmjavanmard@solarcity.com FAX STREET ADDRESS 391 Foster City Blvd CITY,STATE,ZIP Foster City, CA 94404 PHONE 650.477.6430 ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS.LIC# COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE USE OF r—/SFD or Duplex ❑ Multi-Family PROJECT IN WILDLAND PROJECT IN STR CTURE: ❑ Commercial URBAN INTERFACE AREA ❑ Yes ❑ No FLOOD ZONE ❑ Yes ❑ NO SOLAR PANELS 1 ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PANELS: NUMBER OF PANELS/UNITS: KILOWATTS(COMMERCIAL ONLY): ' h�� TOTAL VALUATION: OO �fy500 .c� c DESCRIPTION OF WORK Installation ( ) rooftop flush mounted solar panel loll RECEIVED By:nf-�� By my signature below,I certify to each of the following: I am the prope� o r authorized agent to act on the property owner's behalf. I have read this application and the information I have provided is correct. I have read t Des i on of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to building construction. I authoriz rept atives of Cupertino to enter the above-identified property for inspection purposes. Signature of Applicant/Agent: Date: [7 f' 1 & SUPPLEMENTAL F ATION REQ OFFICE USE ONLY OVER-TAE-COUNTER u ❑ EXPRESS U ca ❑ STANDARD x U_ ❑ LARGE a, ❑ MAJOR P T,App_201 1.cloc I•evised 03/16/11 ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID-INTER11ED VIA A FLASHING WILL BE PAINTED TO MATCH EXTERIOR AC ALTERNATING CURRENT UL-LISTED POWER-CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONC CONCRETE 3. A NATIONALLY-RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING ;�;;- PLOT PLANS EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, ,�: . ,� C _ OP. FSB FIRE SET-BACK A SIGN WILL BE PROVIDED WARNING OF THE OFFI GALV GALVANIZED HAZARDS PER ART. 690.17. AT>£ GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE PLANNING DE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. CUPERTINO I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). c • Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER CC MUNITY DEVELOPMENT DEPARTMENT •� "` Digitally J Igned BUILDING DIVISION-CUPERTINO kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC APPROVED �, ^ LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E).This set of plans and specifications MUST be kept at the = � MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH P U 6IN-,dL ring construction. It is unlawful to make any _ + by Matthew W• (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED cRyant ss or alterations on same,onto deviate NEUT NEUTRAL UL LISTING. therefrom without approval from the Building Official. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE BaileyPE OC ON CENTER UL-LISTED LOCATION PROVIDED BY THE Tha stampil 9 of this plan and specifications SHALL NOT PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDINCpe,held tc permit or to be an aA ppr al of the violation POI POINT OF INTERCONNECTION HARDWARE. of any prc vision f y Ci ance or State Law. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS BALL BE Date: 2016,04. 18 SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTOR-. 4" S STAINLESS STEEL DATE l STC STANDARD TESTING CONDITIONS PC7RMIT IVO. ��j(� ���- � 1 ` -06'00'� � TYP TYPICAL RECEIVES - f 111:21 .04 0 0 0 UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER e-L'Ji t VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT lay ' PV1 COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS LICENSE GENERAL NOTES PV5 THREE LINE DIAGRAM � ��_� Cutsheets Attached CA # 888104 1. ALL WORK TO BE DONE TO THE 2013 CALIFORNIA BUILDING CODE, 2013 CALIFORNIA CUPERTINO C-10 PLUMBING CODE, AND THE 2013 CALIFORNIA Ir Building Depat-,neat RESIDENTIAL CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH A THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY MODULE GROUNDING METHOD: . ZEP SOLAR THE 2013 CALIFORNIA ELECTRIC CODE. 1r TE AHJ: Cupertino.. � REV BY DAC- REV UTILITY:-Pacific Gas,and Electric Company PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN IDB NUMBER: fig-8507155 00 DEB BISWAS Deb Biswas RESIDENCE Tony Chavez CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: ►�����. olar ity NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 926 SEPTEMBER DRIVE 1.82 KW PV ARRAY PART OTHERS OUTSIDE THE RECIPIENTMODULES: 3055 gearview Way ORGANIZATION, EXCEPT IN CONNECTION WITH TH CUPERTINO,P E R TI N O� C A 9 5014 THE SALE AND USE OF THE RESPECTIVE (7) REC # REC260PEZ SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: San Mateo,CA 94402 PERMISSION OF SOLARCITY INC. INVERTER: T:(650)638-1028 F:(650)638-1029 ABB PVI-3.0—OUTD—S—US—Z—A COVER SHEET PV 1 4/18/2016 (888)—SOL—qTY(765-2489)www.solarcitycom PITCH: 18 ARRAY PITCH:18 MP1 AZIMUTH:159 ARRAY AZIMUTH: 159 FEssh MATERIAL:Comp Shingle STORY: 1 Story. E 4 937 �. "iciCP.. 1v� Nk .. . Digitally signed by Matthew WW. Al . Inv O D LEGEND Bailey PE (E) UTILITY METER & WARNING LABEL Date: 2016.04. 18 m� INVERTER W/ INTEGRATED DC DISCO ' & WARNING LABELS 14:21 : 14 -06'00 © DC DISCONNECT & WARNING LABELS Front Of House © AC DISCONNECT & WARNING LABELS OB DC JUNCTION/COMBINER BOX & LABELS _ F 3' FSB _ ' B �D DISTRIBUTION PANEL & LABELS - ----- ---- -- '17 Lc LOAD CENTER & WARNING LABELS a� MP1 I M DEDICATED PV SYSTEM METER ml Im U-I IU- MI IM O CONDDUIIT RUNONLOCATIONS CONDUIT RUN ON INTERIOR _"1`j t O GATE/FENCE � T'I�® I HEAT PRODUCING VENTS ARE RED ,!,iiClir!7 �c=Pat-nent INTERIOR EQUIPMENT IS DASHED /� EVIE' VSITE PLAN N �.'v si: CC-IMPLIANCE TOTAL ARRAY AREA (SF): 127 W r TOTAL ROOF AREA (SF): 2697 Scale: 1/8" = 1' 0 1' 8' 16' F TOTAL ARRAY AREA IS m 4.7 s PERCENT OF TOTAL ROOF AREA CONJB-9507155 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: ■ CONTAINED SHALL NOT BE USED FOR THE DEB BISWAS Deb Biswas RESIDENCE Tony Chavez . BENEFIT ITBEDISCLOSED IN SOLARCITY INC.,SRIMOUNTING SYSTEM: 926 SEPTEMBER DRIVE 1.82 KW PV ARRAY 'i,�Solar . qty PART TO OTHERS OUTSIDE THE RECIPIENTS Comp Mount Type C ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: CUPERTINO, CA 95014 3055 gearview Way THE SALE AND USE OF THE RESPECTIVE (7) REC # REC260PEZ Son Mateo,CA 94402 PAGE NAME SHEET: REV: DATE SOLARCITY EQUIPMENT, WTHOUT THE WRITTEN INVERTER: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. ABB PVI-3.0—OUTD—S—US—Z—A SITE PLAN / / 4 18 2016 (888)—SOL—CITY(765-2489)www.solarcityeom S1 4" 2 8'-6" -2" 5'-1» (E) LBW SIDE VIEW OF MP1 NTS A MPI X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 72" 24" PORTRAIT 48" 20" RAFTER 2x6 @ 24" OC ROOF AZI 159 PITCH 18 ARRAY AZI 159 PITCH 18 STORIES: 1 C.J. 2x6 @16" OC Comp Shingle-Skip Sheathing PV MODULE 5/16" BOLT WITH INSTALLATION ORDER FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. (4) (2) SEAL PILOT HOLE WITH ZEP COMP MOUNT C POLYURETHANE SEALANT. ZEP FLASHING C (3) (3) INSERT FLASHING. (E) COMP. SHINGLE (4) PLACE MOUNT. a '�E ,uildi� (E) ROOF DECKING (2) V I f O 5/16" DIA STAINLESS (5) (5) INSTALL LAG BOLT WITHt::r„= 9 �epar�ent bhp H :'.'�:�•7 SEALING WASHER. ��s>y STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH REV1E�E� (2T SEALING WASHER 1 /2" EMBED, MW) G(6) BOLT & WASHERS. Fir CopE Co (E) RAFTER Revlewed By. �/fPLIAPVCE STAN DOFF S CONFIDENTIAL— THE INFORMATION HERON JOB NUMBER: PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE �B-9507155 00 OF DEB BISWAS Deb Biswas RESIDENCE Tony Chavez , SolarCity. NOR SHTALL IT BENDISCLOSED N WHOLE OR IN M0om SYSTEM: 926 SEPTEMBER DRIVE 1.82 KW PV ARRAY ''"� Comp Mount Type C PART IZ OTHERS OUTSIDE THE RECIPIENT'S MODULES: C U P E R TI N 0 3055 aeardew Way ORGANIZATION, EXCEPT IN CONNECTION WITH CA 95014 THE SALE AND USE OF THE RESPECTIVE (7) REC # REC260PEZ Son Mateo,CA 94402 SOLARCITY EQUIPMENT,WITHOUT THE WRITTEN INVERTER: PAGE NAME SHEET: REV: DAIS T.(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. ABB# PVI-3.0—OUTD—S—US—Z—A STRUCTURAL VIEWS PV 3 4/18/2016 (888)—SOL—CITY(765-2489)www.solareityeom UPLIFT CALCULATI®NS g� 04.18.2016 PE" V system structural Version#56.4 6,'SolarGty. es0 n Software groject""Info>tmatiosr.&Table Of°Can is Risk Category IT SleekNtount"A__..__ Com Roof Camp Roof _ �_. __. L ers.of Cam .Rooffn Z ' Roof Slope ry 180 Rafte'r`5"acro PV System Module Orientation_ __.�_._ p._._ Landscape and Portrait 1425(_._._. _ _. __. .._. . PV Module Width 39 PU Module Length.__ _ _66 _ Standoff Attachment Hardwares_ �� � - Com "Mount T e-C, RLidtaced-Groiaitd/Roof L!VejSi otiv Loads;'_ Ground Snow Load pg' _ 0 0 psf _ ASCE Table 7-1 A6CE_�q_.,7. -1 Roof Snow Over PV Modules. 0.0 "sf ASCE.E 7.4-1 Wind Desilgn Code _ ASCE 7-10 ° Ind lJesign. lethod _a_. a� - �r w.< Paiafly/ ully Enclosed Nletfiod Basic Wind Speed V 110 mph ___ fig 26 S-lA Roof Style Gable Roof F>g.3o a ziUajas'A%"s _._ __.w. _._. . _ __. . -_ _. _ . _ MeanRoof Height- h - i5 ft'... _ -- Section._26.2',- Effective Wind Area 1 Module A 17.8 sf IBG 1509.7.1 Wind Pre' ssure.Calidulatinii CoefficiidntS Wind Pressure 6cposure x _ . �'.__. _ ._ _ _0.85 . _ _ Table 30.3-1 TopahicFacoan2 g ----- --_ Wind DirectionalityFactor_ Kd__a _ 0.85 �Secbon 26.&1 Im ortance;Factor° I NA Velocity Pressure qh qh=0.00256(Kz)(Kzt)(Kd)(V^2) Equation:30.3-1 22.4 psf E)dt Pressure Coefficient(Up) GCp(Up) -0.88 Fig.30 4 2N6/C_5AjR Ext iessure_CoAkI1ent Doavn Ge " Down Fg.30.42rVejt sA]i3 Design Wind Pressure P p= h GC E uation 30.4-1 WlhdPresSure Up- _ �, �`Ku Wind Pressure Down down :.16.0 A116Wable;Standaff S a"can s X-®irect on Y.Direi ion. Max Allowable Standoff Spacing_ Landscape_. __.. _. _..__. 72n Standoff Configuration Landscape Not Staggered ®R 7p Max Standoff Tributary Area _W Trlb 20 sf i C U P E R TI I p y O PV Assembly Dead Load � y W PV 3 p4 I- lding Departmentwet Wmd,Uplitt_atStand-if . : T-adOf ,4 UpliftLLCa aci of Standoff Tallow 500 lbs _. P ty__ _ _. _..v ,.. - ,yr-' Max Portrait 348/0 _ 66" p 9 H _ MaxAlloyda6leCanblever _P,ortrait __.._ 20 Standoff Conf muration Portrait Not Staggered ;.E®FG. COMPLIANCE sf Max StandoffTribataa_ry,Area_.. __ _� Trtb,r� _�_-_-__._ ?��. __ } --viewed PV Assembly Dead Load YW PV psf - -a wet Wind Uplift at,5tandoff._____ ._._ actual_.. F-219 Uplift Capacityxof Standoff T allow 500 lbs __r' "°a. ____ - _ _ _ ____ _. ,- ._. - . _. _, Standoff Demand Ca ar i DCR JB-9507155 O O CONFIDENTIAL- THE INFORMATION HERON JOB NUMBER: PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE DEB BISWAS Deb Biswas RESIDENCE Tony Chavez �SolarCity.BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: A'0 NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 926 SEPTEMBER DRIVE 1.82 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES. CU P E R TI N 0, C A 9 5014 ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 Clearview Way THE SALE AND USE OF THE RESPECTIVE (7) REC # REC260PEZ �: REy, pA�. San Mateo,CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. INVERTER: ABB# PVI-3.0-0UTD—S—US—Z—A UPLIFT CALCULATIONS PV 4 4/18/2016 (abs)-SQL-CITY(765-2489)www.salaraityaam GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (N) GROUND ROD Panel Number:NoLobel Inv 1: DC Ungrounded INV 1 —(1)ABB# PVI-3.0—OUTD—S—US—Z—A LABEL: A —(7)REC # REC260PEZ CA # 888104 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:104833837 Tie—In: Supply Side Connection FCI Inverter; Zigbee 3000W, 240V, 96% PV Module; 260W, 236.6W PTC, MC4, 40mm, Black Frame, ZEP Enabled C-10 Underground Service Entrance INV 2 Voc: 37.8 Vpmax: 30.7 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER �E� 100A MAIN SERVICE PANEL E 100A/2P MAIN CIRCUIT BREAKER ADJUST MIN. ACTIVATION VOLTAGES! Disconnect HAMMER CUTLERInverter 1 PAR 3 2 ABB ki I A 20A PVI-3.0—OUTD—S—US—Z—A __1 lo A L1 T-v 100A/2P B L2 N 1 (E) LOADS __________ _EGa Dc+ Dc+ Vstdrt = 200V GND --------------------------- --- /IOA GEC N DC- DG MID 1: 1X7 GND EGC EGC ---------------------------------------- --------------------� I I I N I I I o I z z I � I I TO 120/240V ***Supply Side Connection to be field listed*** SINGLE PHASE UTILITY SERVICE ; �,. Digitally signed _ a' _C0 by Matthew W. CUPER-rs, O - m ��. g De —�_ ,�� �193? 8uildin � ��.� ` r�artment EXP . Bailey PE U �, s t it) ��`' REVIEINED ;_ R CODE GY �� Date: 2016.04.1 8 CA�-1 r;evlewec, OWPLIANCE 14:21 :25 -06'00' �� Voc* = MAX VOC AT MIN TEMP Ol (1)Gro�gd Rod (1)CUTLER—HAMMER DG222NR8 �� ®� 5 8 x 8, Co per Disconnect- 60A, 24OVoc Fusible, NEMA 3R —(2)ILSCO#IPC 4/ r6 —(1)CUTLER— A�IMER DGIOGNB Insulation Piercing Connector, Main 4/0-4, Tap 6-14 Ground Kgit 60-100A, General Duty(DG) S —(2)FERRAZ SHAMUT 0 k632 SUPPLY SIDE CONNECTION. DISCONNECTING MEANS SHALL BE SUITABLE Fuse Reducer 3 A Fuse for 60A Gip, 250V I AS SERVICE EQUIPMENT AND SHALL BE RATED PER NEC. —(1)CUu9R—HAMMER #DS16FK Class R Fuse Kit —(2) Fuse Z20 A 250V,#TRR20ass RK5 PV BACKFEED OCP V(1)A #6, THWN-2, Black 1 AWG #10, THWN-2, Black (2)AWG #10, PV Wire, 60OV, Black Voc* =288.18 VDC Isc =9.01 ADC WG (1)AWG /6, THWN-2, Red ®14I—(1)AWG #10, THWN-2, Red O (1)AWG#10, THHN/THWN-2, Green EGC Vmp =214.9 VDC Imp=8.5 ADC (1)AWG 16, THWN-2, White NEUTRAL Vmp =240 VAC Imp=14.5 AAC (I)AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=14.5 AAC } (1)Con0uit Kit;.3/4'.EMT .. ... .. . .. . . . . . .. .. . . . . .. . . .. . . . . .. .. . . . . —(1)AWG #6,,Solid Bare.Copper. GEC, , . . (1)Conduit.Kit;.3/4'.EMT. . . .. . . . . . . . .. ...-.(1)AWG #8,.T}IWN72,.Green . . EGC/GEC.—(1)Conduit.Kit;.3/4".EMT. . .. .. . I CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: PREMISE OWNER: DESCRIPTION: DESIGN: JB-9507155 00 CONTAINED SHALL NOT USED FOR THE DEB BISWAS Deb Biswas RESIDENCE Tony Chavez �i �/ BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: ��ei�®��rC�ty® NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C ORGANIZATION, EXCEPT IN CONNECTION WITH 926 SEPTEMBER DRIVE 1.82 KW PV ARRAY PART OTHERS OUTSIDE THE RECIPIENTS MODULES C U P E R TI N 0r CA 95014 3055 Clearview Way I THE SALE AND USE OF THE RESPECTIVE (7) REC # REC260PEZ SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV: DATE San Mateo, 94402 PERMISSION OF SOLARCITY INC. INVERTER. LF.(650)638-1028 F:(650)638-1029 ABB PVI-3.0—OUTD—S—US—Z—A THREE LINE DIAGRAM PV 5 4/18/2016 (668)-SOL-CITY(765-2489)www.solarcity.com 1-NINGo -SOURCE Label Location: Label Location: Label Location: (C)(IC)(CB) PV SYSTEM (AC) WARNING (DC)(INV)(CB) Per Code: DISCONNECT FORRIC _ Per Code: ELECT CRC R331.2 OPERATION D CONDUCTORS• OF CK • CEC 690.35(F) Label Location: �HOTOVOLTAIC SYSTEM ARE TO BE USED WHEN E ENERGIZED ■ • (DC)(INV) �• INVERTER IS DISCOPer Code: UNGROUNDED CEC 690.14.C.2 Label Location: A® (DC) ELECTRIC, Per Code: SHOCK + +-■ Label Location: ■• • • CEC 690.17 MAXIM -• (DC)(INV) ' • • _ POINTPer Code: • ® ' D MAXIMUM POWER- •- -® • .• • CEC 690.53 VOLTAGEMAXIMUM SYSTEM V Label Location: WARNING (POI) INVERTER Per Code: OUTPUT CEC 705.12.D.7 CONNECTION Label Location: •• NOT REL06ATF (DC)(CB) THIS •VERCURRENT DEVICE SHOCKELECTRICAL HAZARD Per Code: ■• NOT TOUCHCEC 690.17 TERMINALSON BOTH LINE AND ••■ SIDES MAY ■ IN THE OPEN POSITION Label Location: DC VOLTAGEPHOTOVOLTAIC POINT OF (POI) ALWAYS PRESENT WHEN INTERCONNECTION Per Code: SO-LAR MODULES ARE WARNING: ELECTRIC SHOCK-• ■ • HAZARD. ,• • TOUCHCEC 690.54; CEC 690.17 TERMINALSTERMINALsi ON BOTH THE LINE AND LOAD SIDE MAY ■ IN THE OPEN POSSERVICE ITION. FOR Label Location: 'E-ENERGIZE BOTH SOURCE D MAIN BREAKER. e ® (INV) PV POWER SOURCE Per Code: MAXIMUM AC A IF A GROUND ELECTRIC FAULT• •INDICATED CEC 690.5(C) •PERATING CURRENT MAXIMUM AC NORMALLY GROUNDED _ •- •- VOLTAGE • ■ UNGROUNDED AND ENERGIZED rCUPERTINO Label Location: t ,�~ �1r+9 ©ePartrnernt Label Location: (D)(POI) " Ai " C ^ j PHOTOVOLTAIC A (AC) (POI) Per Code: F ,-: 'f SVI (AC):onduit connect PHOTOVOLTAIC /ED FpE C� Per Code: ;. ■ CEC 690.64.8.4 (C): DISCONNECT Fzevfewed Lo, 'gh"CE (CB): Combiner Box CEC 690.14.C.2 (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit Label Location: Label Location: (INV): Inverter With Integrated DC Disconnect (AC) (POI) CAUTION (POI) (LC): Load Center OPERATING CURRENT Per Code: DUAL'• •_ Per Code: MAXIMUM AC CEC 690.54 • • CEC 705.12.D.7 (M): Utility Meter OPERATING VOLTAGE, (POI): Point of Interconnection CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR Jbbdifj. 3055 Clearview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR MALL IT BE DISCLOSED San Mateo,CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, LabelSet T:(650)638-1028 F:(650)638-1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE /� f (888)SOL-CrfY(765-2489)www.solarcity.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. ° 013;�, f^SolarCity Zep Solar Next-Level PV Mounting Technology ',`,,SolarClty ZepSolaf Next-Level PV Mounting Technology Zep System Components for composition shingle roofs Leveling Foot x, Ground Zep �. Interlock r Leveling Foot Part No.850-1172 ETL listed to UL 467 ,yam t Zep Compatible PV Modulen Zep Groove .: RoolAttachment Array Sklrt ,' r Comp Mount Part No.850-1382 Listed to UL 2582 Mounting Block Listed to UL 2703 oMPq a..a, `��e�� Description • PV mounting solution for composition shingle roofs Fq — �. Works with all Zep Compatible Modules °OMPp�� Auto bonding UL-listed hardware creates structural and electrical bond • Zep System has a UL 1703 Class"A"Fire Rating when installed using modules from any manufacturer certified as"Type 1"or"Type 2" Interlock Ground Zep V2 DC Wire Clip UL LISTED Specifications Part No.850-1388 Part No.850-1511 Part No.850-1448 Listed to UL 2703 Listed to UL 467 and UL 2703 Listed to UL 1565 • Designed for pitched roofs • Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 „ • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and UL 467 • Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72"and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices • Attachment method UL listed to UL 2582 for Wind Driven Rain Array Skirt,Grip, End Caps Part Nos.850-0113,850-1421, 850-1460 zepsolar.com zepsolar.com Listed to UL 1565 y'r C v PER TI O ,850-1467 rtf� �3Uiiding DP his doc n do s no c a any xp ss wa an y by Z p Sola o abo i s p od c s o s vic s.Z p Sola's sol we an y is con ain din h w i n p od c wa an y fo This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the wrilte "o"duxfw rentypeen`for t each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sale specifications referred to in the product warranty.Th ly responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. responsible for verifying the suitability of ZepSolat's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. E_`"i.gj Doc n#800-890-00 R v Da las xpo d: Nov b 3,20 52:23 PM Document#800-1890-001 Rev Date last exported: Novembe Rr�l3u21�4b�v 4l FC)p COD CC)MPLIAWCS 1�eviewed By Solar inverters Additional highlights: 3 — RS-485 communication interface ABB (for connection to laptop or data string inverters logger). r — Integrated Arc Fault Detection and Interruption(-A Version). ....1 .. iI Technical data and types • :' Type code PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US PVI-4.2-OUTD-US Al$ ;Mechanical specifications Nominal output power 3000W 360OW 3w 380OW 420OW ................................................. .. .. fi0 000, 0i 3 Maximum output power wattage 3000 : 33001 3300 3 0 4 400 300 420 420 4 0 4600 460 ........................................................ W W W W W W W W W W W Rated gnd AC voltage 208V i 240V 277V 208V 240V 277V 208V 240V 277V 208V 240V 277V I Input side(DC) Number of independent MPPT channels 2 2 2 2 ....... Maximum usable power for each channel-._..... _._....-.-.-2000W...._... •.•. .••••..•.-3000W.......--. ._..-..-.3000W.•..•..........................-..3000W •......•.. ............................................................ ................. ............... .............. ............. Absolute maximum valla e max 600V .................._g..._N........)............-................................................................................................. .. ... .. ............................................................................. I t t Start-up voltage(Vstart) i 200V. 120-350 ... .." . ..,. �'`��� {P E 1 N .... ... ....................:.................................................................... �. .......... 4s lJ f .Full power MPPT voltage range....................................................160-530V...................................120-530V..................€.. 140-530V..................................140-530V............. Operating MPPT voltage range 0 7 x Vstart-580V"(>=90V)" " r De arTnent w. _". _ : . .. . .. .. .................................... .......... Building p� 1 Maximum current(Idcmax)for tiotn MPPT in :' 20A 32A 32A 32A Parallel•.•••••. ..... s................................ ` ts. f6K....... _:.......................................................................................................... ` Maximum usable current per channel 10A .16A ................ ......-....."."....16A........•...•. . .........16A......... ..•.....• 0 1. ,, Maximum short circuit ciirrent limd per 12.5A 20.OA 20.OA 20.OA gchannel .... ..... .................. .. '-....................................................................................................... I": 2 airs ........... . Number of wire landin terminals er cfianne .................................................g....................p.................... ...................................................... ....t?......t............._WG1....AWG.............................................................. NCE �xnn r Array wiring termination Terminal block pressure camp,A 0- 4 ;Output side(AC) i 10/ Spilt 10/ 10/ Split- 10 10/ Split 10/ 1 Split- 1fd/ RE�;lE�l1lED FOR CODE CO�hPL Grid connection type -- ................................................................._.............................'....?.N...._._0/3W. .....?W........?W......0/3W..:..... W..........?W...: fd/3W.....2t!!/..... 2W i fd/3W........?W....... ��jG' Adjustable voltage range(Vmin-Vmax)(V) 183- 211- ' 244- 183 211 244- 183- 211- '. 244- 163- 211- Reviewed ByBY M, ..................................................... ?64. .: 304V ` 228V 264V ; 304V : ?28V...i•264V...;..304V• ;••2?8V. ..264V...;.•304V.... ._, Gridfrequency..........................................................._i.......................... .......60Hz................... Adjustable grid frequency range 57-60.5Hz Maximum current 14 5 14.5 i 12.0 17.2 46.0 .6.016.020.0 i 20.0 .............................................................................................................[..._!\aw,s.._:...!%%Is........_Awrs.......P!nk,s...::....Aa,us....:..._Aa,ns....[..._!�ans.._:....!4nas.._[..._Awns....[...!aa,.,s......._Aarrs.._:........a,ns..... Power factor >0.995 .............................................................................................................:...........................................................................................:.................................................................................................................................................... Total harmonic distortion.at rated power <2% ........................................................................... .................................................................................................................................................................................................................................................................. This family of single-phase string The high-speed MPPT offers real- Highlights: Grid wiring termination type. . .............. Terminal block,Pressure clamp,AWG10-AWG4 inverters complements the typical time power tracking and improved — Single phase and split phase output kinput protection devices number of rooftop solar panels energy harvestin rid connection. Reverse polarity protection Yes ...................... ......................... ..... ... .. ........... ...................... ... P P 9Y 9• 9 .Over-voltage protection type Varistor,2 for each channel :......................................................................................................................................................... ...... ......... .......... enabling home-owners to get the most The flat efficiency curve ensures high — Wide input range for increased PV array ground fault detection Pre start-up Riso and Dynamic GFDI(requires floating arrays) efficient energy harvesting for the size efficiency at all output levels allowing stringing flexibility. I Output protection devices of theproperty. a consistent and stable performance — The high speed and precise MPPT Anti-Islanding protection .Meets UL 1741/IE...... requirements. P 9 P P Over-voltage protection type ................... .......... ...................... ........ ...Varistor,..2.� 4%L,-G) across the entire input voltage and algorithm Offers real time power Maximum AC OCPD Rating i.20A i 20A i 15,4 25A 20A"" i 20P 20A 20A_,;20A 25A 25A i 25A This inverter offers a dual input output power range. tracking and improved energy I'Effic,ency section that processes two strings The transformerless operation gives the harvesting. Maximum eff(ciency . .."... % 7% 97% CE6 efficiency ; 96% with independent Multiple Power Point highest efficiency of up to 97.0%. — Outdoor NEMA 4X rated enclosure [Operating performance. Tracking(MPPT). The wide input voltage range makes for unrestricted use under any Night time consumption <0.6w This is especially useful for rooftop the inverter suitable to low power environmental conditions. Stand-by consumption <8w [Communication= " installations with two different installations with reduced string size. — Integrated DC disconnect switch User-interface 16 characters x 2 lines LCD display orientations from two sub-arrays This rugged outdoor inverter has been in compliance with international Remote monitoring(1XRS465 Incl)" VSN7o0 Data Logger(opt.) oriented in different directions.(For designed to be a completely sealed Standards(-S Version). ;Environmental - Ambient air operating temperature range -131F to+140'F with derating above 122*F(50 C) ........... .....................,. example: East and West) unit able to withstand the harshest Ambient air stora a temperature range 4o°F to+1760F.(4o C to+8o C) .........................9..................................................................................................................................................... ........ The dual input sections with environmental conditions. Relative humidity ............ . 0-100 RH condensing ........"..........•.............."..•...•......"....._......_..._.............. .. ............................ .... independent MPPT enable a more Acoustic noise emission level <50 db A Cv?1 m ................................................... Maximum operating"altitutde without derating 6560 ft(2000 m) optimal energy harvesting condition. Power and productivity 1.Capability enabled at nominal AC voltage and with sufficient DC power available. for abetter world' 2 ABB Solar Inverters I Product flyer for PVI-3.0/3.6/3.8/4.2-TL-01JTD rR` E E P E P� K E N E R G Y ZUNK 4 n s9'u2 EFFICIENCY HIGH PERFORMANCE _-.- ( � YEAR PRODUCT WARRANTY SOLAR PANELS YEAR LINEAR POWER OUTPUT WARRANTY J _U_C ,PEAKUS IMPORT-DUTY FREE 1'1x d7.2d ENERGYk47TEMPERATURE RATINGS 1 Y t 7­1 3 i I NommalOperatmgCeltTemperature(NOCT) 457 C(t2°C) (emperatureCoeffineotofPMpn 040°10/C ..... .._...... ......... (� t 7emperatuieCoefficientofUOc 027 V C 1 Temperature Cpefficient of lsc 0 024%/C RKP' Energy Lin _5 h,les CJ�I�(', All measurements in inches s o, g panelsare the perfect chatce far buildlgAT °..SC)lar SyS� rnSs ht3t CQiT#�lnC',pn Ic3Stln ,- Nominal Power-P,p(Wp) t�6o j efiType, '60REC_P.E,multi crystatlme , Product quality with reilable power,output Watt Class Sorting-(Wp) 5 3strmgsoi'20cells with'bypassdlodes R� €C31T11Jlne5}llgh ql allty°{�;25lgn and NominalPowerVoltage V�pP(V) 307 =Glass0:125insotarglasswlth,antl reflection surface treatment NominalPowerCurrent-I (A 850 Mpv ) kSheat. Rouble layer highlyresistantpotyester manUfactu'rin standards td. rodU"ce hl h I � �� Open Circuit Voltage-Voc(V) 378 `{ n Izedaiiimmum(b(ack) erfor�Tlance o(ar P46615,with Frame Aad ! P ShortCircuitCurrent-Isc(A) 901 ZepGroovecompafible i �UnCC)mpr�llTtisingqualtty PanelEfficiency(%) 158 Junctlon8ox � ",'AP ( > ',. indicated values of l c,Voc and PMpp at standard Test conditions(STC) ,' The electrical characteristics are within of the 0156 in(12AWG)solar cable 2 x`47241 n Values atstandard test conditions STC(airmass AM 1.5.irradiance 1000 W/m',cell temperature 77°F(25°C)). COnneCtnrSi ''H4 Ampfiengl i;�y l.l��, l ,3, ,;, ,,, ;.,, At low irradiance of 200 W/m2(AM1.5&cell temperature 77°F(25"C))atleast97%of the STC panel efficiencywill be achieved -. I�33� ]iti( ®� t Orlgm MaiietnStngapPre 1111 � t[I i�a(I�il i (1111..1: r r. i tMAiIMUM RAT NGS,. r> W or fl + 4 `+&5 C t Nominal Power-Pvp( P) 197 atwnalTem e�ature �48 Nominal PowerVoltage-VMpp(V) 290vlaxrmum5yyste,6v tt,ge 1000VUL M. NominalPower Current IP(A) 681 Deslgnloat 501bs(ft?(240pPa)long`sltle pld 30tb/ftp{1436Pa)shortsida OpenCircuit357 P ZEP GROOVE FRAME l i ShortCircuitCurrent-Isc(A) 724 Max Sera es,useRatIng 75A . . . . . . . . . . . . sl NominaloperatingcelI emperatureNOCT(800W/m',AM1.5.windspeedIm/s,ambient temperature 687(20°C). NiaxReverM Current '15A l r 1 } E pG ,: ICATION J�ZT r rv, 10 year productwarranty. Dimensions; 65.55x3902xi:57i0G6Sx991x40mm) c �L us 25 yearlinearpoweroutputwarranty Area 17,75ft2(f.65m�) U5IMPORT EASYTO` LISTED (max,degres Sion in performance of 0.7%p.a.). DUTY FREE INSTALL Werght 1 4431b:(19Ski) -� _ UL 1703,Fire ra ting:Type 1,Class C r Q Note( All given specifications aye sub}ectto change ` �,. xvithoutnotic@atan time. REC is a leading global provider of solar energy solutions. With more than 15 years of experience,we offer sustainable,high performing products,services and investments for the solar industry.Together with our partners,we create value by providing solutions that better RE C meet the world's growing energy needs.REC is headquartered in Norway and listed on the Oslo Stock Exchange(ticker:RECSOL).Ourl,600 employees worldwide generated revenues of USD 647 million in 2013. www.recgroup.cam Buildin DP � nartment REVIEWED FOR CO UE COMPLIANCE reviewed By. - NPo ' ziu arta - UL TO: Building Officials.; Plan Examiners, & Inspectors RE: Underwriters Laboratories Field Evaluation for Supply Side Connections Dear Sir or Madam, SolarCity has partnered with Underwriters Laboratories (UL) the Nationally Recognized Testing Laboratory and Listing Agency. Engineers from UL will be performing a Field Evaluation of a supply side connection in your jurisdiction for a residential solar system. UL will visit this site to inspect the supply side connection, confirm it is NEC compliant, and certify alterations made to the existing main electric panel. After UL has verified the installation, their engineer will apply the UL Field Evaluation sticker to the main electric panel, (see sample below). Upon completion, UL will send a report to your jurisdiction and to SolarCity. Should you have any questions, please feel free to contact the SolarCity representatives listed below. Thank you for your time and consideration on this project. We look forward to working with you. Kyle Breuning FIELD N,0. Engineering Program Manager EVAa UATM PROD (650) 963-5100 x 55803 CT kbreuningCaD-solarcity.com ' Ev�uttian vfiRais�Yatk.t9 tit314 tLtst3tuz� aaaoessclui°jraatnrrrs#�t r itrit+aCa9 ffe_ Your regional Permit or Inspections Coordinator O a) w Z acu 45 a_ cc ^ 0 v w C13 _ a LL a) w UJ W 3055..Qearview way Sari MMeo, CA 94402 T(650)838-1028 (888)SOL-CITY F (650).63-8-1029 S€3LARCITY.COM F AZ ROO 243771, Cry GSLB 83a104, CO EC R041, OR CCO 1.80498, TX TDLR -27.006 KUP-L-Tap" ® Connectors ` `1,H ' u� . Insulation Piercing Co s � L(9T41.2960"Dual Rated 5$G1J� Features Benefits u SPE • Body is molded from tough,resilient glass-filled nylon • Provides high degree of breakage resistance and longdeperldabtuse •Compact design • Saves space •Tin plated copper contact teeth • Easily penetrates most ty es of insulation IPC • Insulation piercin • No need to strip the coITwhich sa esr: ita1lation tini m • Perforated end togs • Break out Basil b handl I y b Y Y , ..,..,: a� • Pre-filled with silicone lubricant • Prevents oxidation and moisture from a mg.. ez taagrear_ �O �e •Versatile • Can be used as a splice or to connectoW^�`�' p p ,/ �, • Increased safety • Contains no external energized parts.Cyan ri ht' on energized con- ductors providing tap conductor is not under load. • Horizontal line grid ,C • Provides a visual guide for proper installation of conductors •Temperature rating 90 W L . �� of H Fig. 1 Fig. 2 Fig. 3 Fig. 4 Catalog Figure Wire Range Current Rating Dimensions Torque Bolt Head Number Number Main Tap !Volts CU AL L W H Ft. Lbs. Size IPC=1/0-2 3 1/0-8 2-8 300(480GroundedYSystem) 130 100 1-7132 1-15/32 2-5/16 16 1J2 IPC-410-6 2 4/0-4 6-14 600 75 60 1-27/64 1 1-7/8 13 1/2 IPC-4/0-2/0 3 .. 4/0-2 210-6, 600 195 150 1-21/32 1-7/8 2-7/8 25 1/2 IPC-250-4/0 2 250kcmil-1 4/0-6 600 260 205 1-718 2-11/32 3-11/32 30 518 'IPC-350-4/0 3 350kcmil-4/0 4/0-10 300(480 Grounded YSystem) 260 205 1-43/64 2-7/16 - 3-1/8 25 5/8 IPC-350-350 4 350kcmil-410 350kcmil-4/0 300(480 Grounded Y System) 350 280 2-43/64 2-23/32 3-1/4 25 5/8 'IPC-500-12 1 500kcmil-250kcmil 10-12 300(480„GroundedYSystem) 40 35 1-43/64 2-7/16 3-1/4 25 5/8 IPC-500-250 1 500kcmil-250kcmil 250kcmil-4 600 290 230 2-27164 2-29/32 3-314 55 5/8-11/16 IPC-500-500 1 500kcmil-300kcmil 500kcmil-250kcmil 600 430 350 3-3/16 3-518 5 75 718-718 IPC-750-500 1 750kcmil-500kcmil 500kcmil-350kcmil 600 430 350 3-3/16 3-5/8 5 75 7/8-718 All wire sizes,unless noted otherwise,are American Wire Gauge(AWG) Tested to UL 486A/B,UL File E6207 4730 Madison Road, Cincinnati, Ohio 45227-1426 Phone 513 533-6200 Fax 513 871-4084 Web site www.iisco.com 105 Canada 1050 Lakeshore Road East, Mississauga, Ontario, Canada L5E1E4 Phone 905 274-2341 Fax 905 274-8763