Loading...
15100132-CANCELLEDApril 21, 2016 Dear Sir or Madam: APR 2 5 2016 13Y V'_V) This letter is to -inquire about cancelling the permit for the following customer: John Wei 10628 John Way Cupertino CA, 95014 Permit # 15100132 The customer has decided to cancel their solar project with SolarCity. We hereby request a refund of fees, If possible. Refund checks can be mailed directly to the following address: ATTN: Iona Villalba SolarCity Las Vegas 6671 S. Las Vegas Blvd Ste. 300 Las Vegas, NV 89119-3290 If you have any questions or need anything further, please let me know. Sincerely, Marjan Javanmard, Permit Coordinator (650)477-6430 miavanmard@solarcity,com IAII);�l ( Aczaal 2-10 M � C - -Y' deo, QA 'Y - q $ v 0 �5' 41earview WO , Un M, — 94402 T (65-W 63AW028 (8, 8) S*LANN F (65M 63N,4029 I OLARCITY C M A -9 R Of 4 -.-I I f,A I CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 10628 JOHN WAY CONTRACTOR: SOLARCITY PERMIT NO: 15100132 OWNER'S NAME: WEI JOHN J 3055 CLEARVIEW WAY DATE ISSUED: 10/16/2015 OW ER'S PHONE: 4087778258 SAN MATEO, CA 94402 PHONE NO: (650) 638-1028 LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL ❑ COMMERCIAL ❑ License Class O P Q9_0 Lic. #_ INSTALLATION (15) ROOFTOP FLUSH MOUNTED SOLAR PANEL (3.9KW)j INSTALL (N) 125 AMP SUB -PANEL. Date ( { Contractor_2. �c ,( i ��under I hereby affirm that I am licenprovisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: Sq. Ft Floor Area: Valuation: $8500 t. I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the APN Number: 35918002.00 Occupancy Type: performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. PERMIT EXPIRES IF WORK IS NOT STARTED APPLICANT CERTIFICATION WITHIN 180 DAYS OF PERMIT ISSUANCE OR I certify that I have read this application and state that the above information is 180 LAST CALLED INSPECTION. correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter( VDAYSROM upon the above mentioned propefor inspection purposes. (We) agree to save Issued bi Date: l 1 indemnify and keep harmless theCity of Cupertino against liabilities, judgments, costs; and expenses which may ccrue nst said City in consequence of the granting of this permit. Add' rr nally, applicant understands and will comply with all non -point source regul ton e Cupertino Municipal Code, Section 9.18, RE -ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is Signature Date_b installed without first obtaining an inspection, I agree to remove all new materials for inspection. Signature of Applicant: Date: ❑ OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER the following two reasons: t. 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for HAZARDOUS MATERIALS DISCLOSURE sale (See.7044, Business & Professions Code) I have read the hazardous materials requirements under Chapter 6.95 of the 2. I, as owner of the property, am exclusively contracting with licensed contractors to California Health & Safety Code, Sections 25505, 25533, and 25534. 1 will maintain construct the project (Sec.7044, Business & Professions Code). compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a)should' I store or handle hazardous material. I hereby affirm under penalty of perjury one of the following three declarations: Additionally, should I use equipment:or devices which emit hazardous air 1. I have and will maintain a Certificate of Consent to self -insure for Worker's contaminants as defined by the Bay Area Air Quality Management District I will Compensation, as provided for by Section 3700 of the Labor Code, for the maintain compliance . th th upertino Municipal Code, Chapter 9.12 and the performance of the work for which this permit is issued. Health &Safety Cod, Secti 625505, 25533, and 25534. 2. 1 have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this Owner or auth ze ag nt• / r� Dater / f permit is issued. jf s. I certify that in the performance of the work for which this permit is issued, I shall ° ' CONSTRUCTION LENDING AGENCY not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I I hereby affirm that there is a construction lending agency for the performance of work's become subject to the Worker's Compensation provisions of the Labor Code, I for which this permit is issued (Sec. 3097, Civ C.) Lender's Name must forthwith comply with such provisions or this permit shall be deemed . revoked. Lender's Address APPLICANT CERTIFICATION ARCHITECT'S DECLARATION I certify that I have read this application and state that the above information is I understand my plans shall be used as public records. correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter Licensed Professional upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Signature Date ALTERNATIVE NER PERMIT APPLICATION '.._,'..,,at T �)—c:t. k1H .t9'a{. :Izi,{.., AEi UPERTIN10 _ C� PROJECT ADDRESS L I APN k ` R q _' OWNER NAME i_ Y \ iid/ ✓✓ PHONEn p I E-MAIL 11 r STREET ADDRESS( CITY, STATE ZIP FAX CONTACT "'Marjan Javanmard PHONE650.477.6430 1:-MA1Lmjavanmard@SolafCfty.com I STREETADDRESS391 Foster City Blvd CITY, STATE, ZIP Foster City, CA 94404 FAX ❑ OWNER ❑ OWNER -BUILDER ❑ OWNER AGENT ❑ CO`1TRACTOR ® CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTORNAIMFSolarCity Corporation LICENSE NUMBER 888104 LICENSE TYPE C10 BUS. LIC g28840 COMPANY NAMESolarCity Corporation E-MAIL mjeSvvUanmard@solarcity...com FAX STREETADDRESS391 Foster City Blvd CITY, STATE, ZIP Foster City, CA 94404 "650.477.6430 ARCHITECT/ENGNEER NAME LICENSE NUMBER BUS. LIC 7 COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE USE OF L9 SFD or Duplex ❑ Multi -Family PROJECT N WILDLAND PROJECT N Commercial URB -AN INTERFACE AREA ❑ Yes ❑ No FLOOD ZONE ❑ Yes ❑ NO STRUCTURE: ❑ ® SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PANELS: NUMBER OF PANELSlUNITS: KILOWATTS (COMMERCIAL ONLY): DESCRIPTION OF WORK Installation I5) rooftop flush Mounted solar panel (� `) kW By my signature below, I certify to each of the following: I am application and the information I have provided is correct. I hav ordinances and state laws relating to building construction. I ark Signature of Appl icant/Agent: ✓ owner or authorized agent to act on the prop e s beh VAI have read this ,-scription of Work and verify it is accurate. I agree to with all applicable local >entatives of Cupertino to enter the above -identified property for inspection purposes. Date: 1(2116/1-5 SQUIRED OFFICE USE ONLY ri ❑ OVER-TPIE-COUNTER f� v ❑ EXPRESS U ❑ STANDARD V d ❑ LARGE .a Cr ❑ MAJOR pV4pp 2011.doc revised 03/16/11 -- CITY OF CUPERTINO FFF FgTTMATnR _ RTTTT.D1XV_' iITV>1C><( T%T ADDRESS: 10628 John Way DATE: 1 011 61201 5 REVIEWED BY: Phuong APN: 359-18-002 BP#: *VALUATION; 1$8,500 rPERMIT TYPE: Building Permit PLAN CHECKTYPE: Alteration / Repair PRIMARY SFD or Duplex USE: p PENTAMATION PERMIT TYPE: SOLAR -RE WORK Installation 15 rooftop flush mounted solar panel (3.9KW); Install N 125 amp sub -panel. SCOPE PME Plan Check: 11ec1r. Plan C'hee5 1"hi b. 1 hon Chef." Elec. Plan Check 0.0 hrs $0.00 Inc,r. I'etr�ril Fr?c" Pbvmb. F't:tTY t TV2: Elec. Permit Fee: IEPERMIT %1tf c.r les'di, Inv). Citi;er 111a b Other Elec. Insp. 0.0 hrs $48.00 IrrsT;. 140th, hisp. Fee: Phemb, hl'S1t, fee: l'lec. Imp. tee: NOTE. This estimate does not include fees due to other Denorttnentc (i.e. Planning. Puhlic Warks. Fire. Sanitary Sewer District. School Dictrirt otr_ )_ Thoco foot oro hncod n" tho nrolirmimnm imfnrsmntinm mmilnhlo and aro nmhi om octisnnto_ Cnmtnrt tho Dont far addn'l ini0_ FEE ITEMS (Fee Resolution 11-053 Eff. 7/1/13,) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 = # Alternative Energy System $236.00 IPHOTOVRES Photovoltaic System Suppl. PC Fee: (F) Reg. 0 OT0.0 1 hrs $0.00 PME Plan Check: $0.00 = amps Electrical $48.00 FIBELEC200 Services Permit Fee: $0.00 Suppl. Insp. Fee: Reg. 0 OTJ 0,0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $48.00 {.,C3n irlict?on .lax: Administrative Fee: 1ADMIN $45.00 Q) Work Without Permit? 0 Yes Q No $0.00 Advanced Planning Fce: $0.00 Select a Non -Residential Building or Structure E) ! , Travel Documentation Fee: ITRA VDOC $48.00 Strong Motion. Fee: IBSEISMICR $1.11 Select an Administrative Item Bldp, Stds Commission Fee: IBCBSC $1.00 9I7I3TQTLS $143.11 $284.00flTLFE $427.11 Revised: 1 otuvzuI b ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A FLASHING WILL BE PAINTED TO MATCH EXTERIOR AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. BLDG BUILDING cUPERTINO CONC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING Building ®Eportment PLOI PLANS DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN B EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. OCT 15 2015 (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING DATE JO i fo j$ EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FOR CODE COMPLIANCE PLANNING DEPT FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE REVIEWED GALV GALVANIZED HAZARDS PER ART. 690.17. Reviewed By: CUPERTINO GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY RECE VFD HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. 1 CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL ZO15 Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). OCT 1 Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER DE's ELOF)MIENT PIEPARTNILNT kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR BUILDIiJG i `'VISION - CUPERTINO BY kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC APPROVED LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). `his set of plan; a- I specifications "MUST be kept at the MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY i,.:c s;te during c��r�ir.�ction. It is unla�,vful to make any NEST NEUTRAL LISTING. -nan es ter dte; NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE 9. - 'nerefr-)m, Wtnc,.! approval from the Building Official. OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE the S:ampinr of It1!; plan and specifications SHALL NOT r PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING be held to pen,Tlt or to be an approval of the violation P01 POINT OF INTERCONNECTION HARDWARE. ofanyny provisi - ' nye City Ordinance or State Law. PV PHOTOVOLTAIC SCH SCHEDULE 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE BONDED WITH EQUIPMENT GROUND CONDUCTORS. DATE �, U S STAINLESS STEEL PERMIT STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT VICINITY MAP INDEX Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT W WATT PV1 COVER SHEET 3R NEMA 3R, RAINTIGHT PV2 SITE PLAN a. PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS PV5 THREE LINE DIAGRAM IsCutsheets LICENSE GENERAL NOTES Attached CA # 888104 1. ALL WORK TO BE DONE TO THE 2013 C-10 CALIFORNIA BUILDING CODE AND THE 2013 CALIFORNIA RESIDENTIAL CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH , .I THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY THE 2013 CALIFORNIA ELECTRIC CODE. a MODULE GROUNDING METHOD: * i .t ' - REV BY DATE COMMENTS AHJ: Cupertino REV A NAME DATE COMMENTS UTILITY: Pacific Gas and Electric Company 1 DESCRIPTION: DESIGN: WEI RESIDENCE John Mcdonald ,I1;COI��rI�` , CONFIDENTIAL —THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER: JB9 5 0 6 2 3 8 0 0 PREMISE OWNER: WEI, JOHN BENEFIT OF ANYONE EXCEPT SOLARCITY INC., JOHN WAY 3.9 KW PV ARRAY 04' J ` Y MOUNTING SYSTEM: [MODULES: 10628 NOR SHALL IT BE DISCLOSED IN MOLE OR IN Comp Mount Type C PART TO OTHERS OUTSIDE THE RECIPIENTS CA 95014ORGANIZATION, TMK OWNER: CUPERTINO, EXCEPT IN CONNECTION MATH7� THE SALE AND USE OF THE RESPECTIVE (15) REC # REC260PEZ ��I 3055 Clearvew Way M * PAGE NAME: REV DATE San Mateo, CA 94402 INVERTER: FRONIUS Primo 3.8 408-777-8258 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. [S5WEE71 T:(650) 638-1028 F:(650) 638-1029 COVER SHEET V 1 10/12/2015 (688)-SCI-CITY (765-2489) www.solarcity.com Fron CUPERTINO Building Depar"el OCT 'I REVIEWED FOR COD E COI Reviewed By PITCH: 18 ARRAY PITCH: 18 MPI AZIMUTH: 270 ARRAY AZIMUTH: 270 MATERIAL: Comp Shingle STORY: 1 Story - I Ff;FND (E) UTILITY METER & WARNING LABEL Ing INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS TOTAL ARRAY AREA (SF): 272 SITE PLAN N TOTAL ROOF AREA (SF): 3164 Scale: 1/8" = 1' w E TOTAL ARRAY AREA IS N 8.59 0 1' 8' 16' PERCENT OF TOTAL ROOF AREA S CONFIDENTIAL —THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE ,108 NUMBER:\\\ JB -9506238 0 0 PREMISE OWNER: DESCRIPTION: WEI, JOHN WEI RESIDENCE DC DC DISCONNECT & WARNING LABELS Al AC DISCONNECT & WARNING LABELS DC JUNCTION/COMBINER BOX & LABELS MOUNTING SYSTEM: DISTRIBUTION PANEL & LABELS Lc LOAD CENTER & WARNING LABELS ODEDICATED PV SYSTEM METER 0 STANDOFF LOCATIONS CUPERTINO, CA 95014 CONDUIT RUN ON EXTERIOR --- CONDUIT RUN ON INTERIOR — GATE/FENCE Q HEAT PRODUCING VENTS ARE RED 1%/ ` 1 INTERIOR EQUIPMENT IS DASHED L -'J SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. TOTAL ARRAY AREA (SF): 272 SITE PLAN N TOTAL ROOF AREA (SF): 3164 Scale: 1/8" = 1' w E TOTAL ARRAY AREA IS N 8.59 0 1' 8' 16' PERCENT OF TOTAL ROOF AREA S CONFIDENTIAL —THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE ,108 NUMBER:\\\ JB -9506238 0 0 PREMISE OWNER: DESCRIPTION: WEI, JOHN WEI RESIDENCE DESIGN: John Mcdonold --ft_I;;I���I�� CO BENEFIT OF ANYONE EXCEPT SOLARCITY INC., WH DISCLOSED IN OLE OR IN 10628 JOHN WAY 3.9 KW PV ARRAY "�' J �/® MOUNTING SYSTEM: NOR SHALL IT BE Comp Mount Type C PART OTHERS OUTSIDE THE RECIPIENTS CUPERTINO, CA 95014 MODULES. ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (15) REC # REC260PEZPAGE NAME 30555 ClemNiew Way San Mateo, CA 94402 SHEET: REV: DATE INVERTER: FRONIUS # Primo 3.8 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. 408-777-8258 SITE PLAN PV 2 10/12/2015 T:(650) 638-1028 F:(650) 638-1029 (688)-SOL—CITY (765-2489) www.solarcity.com SIDE VIEW OF MPI NTS (A�� MP1 X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 7211 2411 PORTRAIT 48" 20" RAFTER C.J. 2X4_@ 24" OC 2X6 @16" OC ROOF AZI 270 PITCH 18 STORIES: 1 ARRAY AZI 270 PITCH 18 Comp Shingle PV MODULE 5/16" BOLT WITH LOCK & FENDER WASHERS ZEP LEVELING FOOT ZEP ARRAY SKIRT ZEP COMP MOUNT C ZEP FLASHING C (E) COMP. SHINGLE (E) ROOF DECKING 5/16" DIA STAINLESS STEEL LAG BOLT WITH SEALING WASHER (2-1/2" EMBED, MIN) (E) RAFTER CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. S1 STANDOFF JOB NUMBER: JB -9506238 00 MOUNTING SYSTEM: Comp Mount Type C MODULES (15) REC # REC260PEZ INVERTER FRONIUS # Primo 3.8 INSTALLATION ORDER LOCATE RAFTER, MARK HOLE (1) LOCATION, AND DRILL PILOT HOLE. (2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. (3) INSERT FLASHING. (4) PLACE MOUNT. (5) INSTALL LAG BOLT WITH SEALING WASHER. C(6)INSTALL LEVELING FOOT WITH BOLT & WASHERS. PREMISE OWNER: WEI, JOHN 10628 JOHN WAY CUPERTINO, CA 95014 408-777-8258 CUPERTINO Building Department OCT 15 2015 REVIEWED FOR CODE COMPLIANCE Reviewed By: W04D\- WEI RESIDENCE John Mcdonold �\�`.• SolarCity. 3.9 KW PV ARRAY ��� • 3055 Clear%iew Way PAGE NAME ' REV DATE Son Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 STRUCTURAL VIEWS I PV 3 10/12/2015 (888)- SOL -CITY (765-2489) www.solarcity.com CUPERTINO Building Department OCT 15 2015 REVIEWED FOR CODE COMPLIANCE Reviewed By: WC D - UPLIFT CALCULATIONS 10.12.2015 PV System Structural Version #49.3 SolarCity Desian Software Project Information & Table Of Contents Risk Category: E BENEFIT OF ANYONE EXCEPT SOLARCITY INC., SHALL BE DISCLOSED OR IN[IN II ��'�� .,;So�arCity. PV System Type NOR IT IN WHOLE SolarCity SleekMount— Comp Roof Comp Roof C U P E R TI N 0, C A 9 5014 Layers of Comp Roofing DULE 2 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE Roof Slope 18° 3055 CleoNew Way Son Mateo, CA 94402 Rafter Spacing SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. 24" O.C. PV 4 10/12/2015 PV System Module Orientation ONIUS Primo 3.8 Landscape and Portrait PV Module Area 266 sf PV Module Width 39" PV Module Length 66" Standoff Attachment Hardware Comp Mount Type C Reduced Ground/Roof Live/Snow Loads Ground Snow Load pg 0.0 psf ASCE Table 7-1 Surrounding Roof Snow 0.0 psf ASCE Eq. 7.4-1 Roof Snow Over PV Modules 0.0 psf ASCE Eq- 7.4-1 Wind -Design Criteria -- Wind Design Code ASCE 7-10 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 110 mph Fig. 26.5-1A Exposure Category C Section 26.7 Roof Style Gable Roof Fig. 30.4-2A/B/C-5A/B Mean Roof Height h 15 ft Section 26.2 Effective Wind Area 1 Module A 17.8 sf IBC 1509.7.1 Wind Pressure Calculation Coefficients Wind Pressure Exposure Kz 0.85 Table 30.3-1 Topographic Factor Kzt 1.00 Section 26.8 Wind Directionality Factor Kd 0.85 Section 26.6-1 Importance Factor I NA Velocity Pressure qh qh = 0.00256 (Kz) (Kzt) (Kd) (V^2) 22.4 sf Equation 30.3-1 Ext. Pressure Coefficient (Up) GCp (Up) -0.88 Fig. 30.4-2A/8/C-5A/B Ext. Pressure Coefficient Down GCp Down 0.45 Fig. 30.4-2AJB/C-5A/B Design Wind Pressure P p = gh GC Equation 30.4-1 Wind Pressure Up p(up) -19.6 psf Wind Pressure Down down 16.0 psf Allowable Standoff Spacings X -Direction Y -Direction Max Allowable Standoff Spacing Landscape 72" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Not -Staggered Max Standoff Tributary Area Trib 20 sf PV Assembly Dead Load W -PV 3 psf Net Wind Uplift at Standoff T -actual -196 lbs Uplift Capacity of Standoff T -allow 500 lbs Standoff Demand/Capacity DCR 39.1% Max Allowable Standoff Spacing Portrait 48" 66" Max Allowable Cantilever Portrait 20" NA Standoff Configuration Portrait Not -Staggered Max Standoff Tributary Area Trlb 22 sf PV Assembly Dead Load W -PV 3 psf Net Wind Uplift at Standoff T -actual -219 lbs Uplift Capacity of Standoff T -allow 500 lbs Standoff DemandjCaeacL I DCR 43.8% CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT USED FOR THE JOB NUMBER: JB -9506238 O O PREMISE OWNER: DESCRIPTION: WEI, JOHN WEI RESIDENCE OtSIGN. John Mcdonald ■ MOUNTING SYSTEM: E BENEFIT OF ANYONE EXCEPT SOLARCITY INC., SHALL BE DISCLOSED OR IN[IN 10628 JOHN WAY 3.9 KW PV ARRAY ��'�� .,;So�arCity. NOR IT IN WHOLE om Mount Type C P }_ PART TO OTHERS OUTSIDE THE RECIPIENTS C U P E R TI N 0, C A 9 5014 ry� DULE ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE 15) REC # REC260PEZ 3055 CleoNew Way Son Mateo, CA 94402 g{E�; REV PATE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. PAGE NAME 408-777-8258 UPLIFT CALCULATIONS PV 4 10/12/2015 T:(650) 638-1028 F:(650) 638-1029 (866) -sol -CITY (765-2489) www.solaralty.cam ONIUS Primo 3.8 Label Location: (C)(IC)(CB) Per Code: CRC R331.2 Label Location: (DC) (INV) Per Code: CEC 690.14.C.2 Label Location: (DC) (INV) Per Code: CEC 690.53 _Label Location: (DC) (CB) Per Code: CEC 690.17 Label Location: (INV) Per Code: CEC 690.5(C) Label Location: (AC) (POI) Per Code: CEC 690.14.C.2 Label Location: (AC) (POI) Per Code: CEC 690.54 Label Location: (AC) Label Location: (DC) Per Code: CEC 690.17 Label Location: (POI) Per Code: CEC 705.12.D.7 Label Location: (POI) Per Code: CEC 690.54; CEC 690.17 Label Location: (D) (POI) Per Code: CEC 690.64.B.4 Label Location: (POI) Per Code: CEC 705.12.D.7 Label Location: (DC)(INV)(CB) Per Code: CEC 690.35(F) TO BE USED WHEN INVERTER IS UNGROUNDED CUPERTINO Building Department OCT 15 2015 REVIEWED FOR CODE COMPLIANCE Reviewed By: w4� a - (AC): AC Disconnect (C): Conduit (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit (INV): Inverter With Integrated DC Disconnect (LC): Load Center (M): Utility Meter (POI): Point of Interconnection CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR�� ie �� 3055 Clearview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED o- . San Mateo, CA 94402 38-1029 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, Label Set +�� -SOL-) 638-1028 89) w) .solar it EXCEPT IN CONNECTION NTH THE SALE AND USE OF THE RESPECTIVE �� SDialtlt (888) -SOL -CITY (765-2489)www.solarcity.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS - (15) REC# REC260PEZ LICENSE BOND (N) #8 GEC TO (N) GROUND ROD Panel Number: Inv 1: DC Ungrounded INV 1 - (1) FRONIUS # Primo 3.8 LABEL: A CA # 888104 C-10 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number: 1008987153 AFCI Inverter; 380OW, 240V, 97%, w/ Antenna PV Module; 260W, 236.6W PTC, MC4, 40mm, Black Frame, ZEP Enabled INV 2 Underground Service Entrance Voc: 37.8 Vpmax: 30.7 INV 3 1 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 100A MAIN SERVICE PANEL E� 10OA/2P MAIN CIRCUIT BREAKER Inverter I IND BRYANT 4 (N) 125A Load Center 3rimaFRONIUS 1 DC- 10OA/2P Primo 3.8 Dc- MP1: 1x8 20A 2P (E) LOADS A / L1 EGC ------------------------� - - �• L2 N DC+ DG I I 50A/2P ---------------------- _--____-__ _EGci GEC Dc+ N DG c- MP1: 1x7 jD'C RN --------------------------------IJI �-----------------� (1)Conduit Kit; 3/4' EMT I I EGGGEC - Z Z 50A/2P --- GEC- --� -- TO 120/240V SINGLE PHASE- - UTILITY SERVICE i TO (E) LOADS C U P E RTI N O I s Building Department I OCT 15 2015 REVIEWED FOR CODE COMPLIANCE Reviewed By: Voc* = MAX VOC AT MIN TEMP POI (2)Bumdy y BIT 2/0 Multi -Cable Connector; 2 Port A (1 )CUTLER -HAMMER � BR220 PV BACKFEED BREAKER /� Breaker, 20A/2P, 2 Spaces A D� - (1)Gr nd Rod 5%8" x 8, Copper - (1) CUTLER -HAMMER # BR250 Breaker, 50A/2P, 2 Spaces - (1)BRYANT # BR48LI25RP Load Center, 125A, 120/24OV, NEMA 3R -- �(1) AWG /8, THWN-2, Black - (1) AWG #8, THWN-2, Red (WFRL) (1) AWG 18, THWN-2, Red -(1)Conduit Kit; 3/4" EMT - -- O - - -------- (1) AWG #10, THWN-2, Black (1) AWG /10, THWN-2, Red ------ AWG X10 P Wire 600 - - (2) V V, Black Voc* = 329.34VDC Isc - 9.01 ADC O (1) AWG #10, THHN/THWN-2, Green EGC Vmp = 245.6 VDC Imp= 8.5 ADC IL^�=LL (1)AWG 18, THWN-2, White Neutral Vmp =240 VAC Imp= N/A AAC L L LL�-LL (1) AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=15.8 AAC (1)Conduit Kit; 3/4'. EMT ... . -(11)AWG }8,. THWN-2,. Green . _EGC ... _- (1) AWG. /8, .THWtJ-2, . Blgok... (WERE).. .... . - (1) AWG #8,. T1 jWN-2,. Green, EGC/GEC .- (1) Conduit, Kit; . 3/4' .EMT ... PV Wire, 600V, Black Voc* 28818 VDC Isc 9.01 ADC (2) AWG y10 Green EGC V p - 214 9 VDC I p- 8 5 AD O (1) AWG #10, THHN/THWN-2, G m - m- C (1) Conduit Kit;.3/4" EMT ................ ...... CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER: J B- 9 5 0 6 2 3 8 0 o PREMISE OWNER: WEI, JOHN DESCRIPTION: WEI RESIDENCE DESIGN: John Mcdonald \\`�SolarCity. INC., ��'� BENEFIT OF ANYONE EXCEPT SOLARCITY MOUNTING SYSTEM: 10628 JOHN WAY 3.9 KW PV ARRAY � NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS Comp Mount Type C }_� MODULES C U P E R TI N 0, CA 95014 J-""" ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (15) REC # REC260PEZPAGE NAME: 3055 Clearview Way San Mateo, CA 94402 SHEET: REV DATE INWERTER: FRONIUS Primo 3.8 PERMISOLASSIONITYEOFISOLARCITY INaCI.T THE WRITTEN 408-777-8258 THREE LINE DIAGRAM PV 5 10/12/2015 638-1028 F: 9 29 (888)-SOLdorcity.com SOlaf�lty ®pSOlar Next -Level PV Mounting Technology 'i SOlafCity ®pSolar Next -Level PV Mounting Technology Zep System for composition shingle roofs QP'GMpA r,6 k' �F ti FACGMPP��O UL LISTED ETV zepsolar.com Ground Zep Interlock ysy s,�e s!o:.ni _ Leveling Foot Zcp Compatible W MOdYte Zcp Groove - - Roof AM hent Array Sklrl ! Description • PV mounting solution for composition shingle roofs • Works with all Zep Compatible Modules • Auto bonding UL -listed hardware creates structual and electrical bond • Zep System has a UL 1703 Class "A" Fire Rating when installed using modules from any manufacturer certified as "Type 1" or "Type 2" Specifications • Designed for pitched roofs • Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467 • Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72" and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices • Attachment method UL listed to UL 2582 for Wind Driven Rain This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of Zep Solar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. 02 27 15 ZS for Comp Shingle Cutsheet Rev 04.pdf Page: 1 of 2 Components zepsolar.com Comp Mount Part No. 850-1382 Listed to UL 2582 & Mounting Block to UL 2703 i) Ground Zep Part No. 850-1172 Listed to UL 2703 and ETL listed to UL 467 Interlock - - - - Leveling Foot Part No. 850-1388 Part No. 850-1397 Listed to UL 2703 Listed to UL 2703 Array Skirt, Grip, End Caps Part Nos. 500-0113, 850-1421,850-1460, 850-1467 Listed to UL 2703 DC Wire Clip Part No. 850-1448 Listed UL 1565 This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole ed ir11 UiPn t v4rNt()r each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referr ct rr t .The cyµ��to��mer is solely responsible for verifying the suitability of Zep Solar's products for each use. Specifications are subject to change witho ice. a'MU,e c.b ,pa rtme nt 02 2715 ZS for Comp Shingle Cutsheet Rev 04.pdf Page: 2 of 2 OCT 5 205 v xk REVIEWED FOR CODE COMPLIANCE Reviewed By:44aa HIGH PERFORMANCE SOLAR PANELS REC PEAK ENERGY REC Pea C!ler gy i--Ii1K �)erie,l sulci panels are the perfect choice for building solar systems that combine long lasting product quality with reliable power output. REC combines high quality design and manufacturing standards to produce high- performance solar panels with uncompromising quality. REC PEAK ENERGY ZLINK SERIES 55.55 30.1 _ •--� sn 39.02'e' EFFICIENCY YEAR PRODUCT WARRANTY YEAR LINEAR POWER OUTPUT WARRANTY OST Y,FR U5 IMPORT DUTY FREE FF TEMPERATURE RATINGS Nominal Operating Cell Temperature(NOCT) 45.7°C(32°C) Temperature Coefficient ofPl_t,, -0.40%/°C = Temperature Coefficient of V. -0 27 %/°C Temperature Coefficient of 1,c 0-024 %/°C All measurements in inches ELECTRICAL DATA P STC REC2613PEZGENERAL Nominal Power-P_p(Wp) Cell Type 60 REC PE multi -crystalline Watt Class Sorting-(Wp) ./_ 5 3 strings of 20 cells with bypass diodes NominalPowerVoltage-V,n(V) 307 Glass: 0.125 in solar glass with anti -reflection surface treatment Nominal Power Current -1� (A) 8.50 Back Sheet: Double layer highly resistant polyester Open Circuit Voltage -Va(V) 37.8 Frame: Anodized aluminum (black) Short Circuit Current - Isc (A) 9.01 Zep Groove compatible Panel Efficiency(%) 158 Junction Box: IP67rated 0.156 in (12 AWG) solar cable, 2 x 47.24 in The electrical characteristics are within /-10% of the indicated values of l ,Va and P„„ at standard Test conditions(STCL Values at standard test conditions STC(airmass AM l.5, irradiance 1000 Wm2, cell temperature 7TF(25'C)). Connectors: H4Amphenol At low irradiance of 200 W/m' (AM 1.5 & cell temperature 77°F (25°C)) at least 97% of the STC panel efficiency will be achieved. -,Igen: Made in Singapore ELECTRICAL DATA @ NOCT REC260PEZ Nominal Power - P,,(Wp) 197 Operational Temperature: -40_.•1185°F(-40...+85°C) Nominal Power Voltage -V�(V) 29.0 Maximum System Voltage: 1000VUL Nominal Power Current-I_(A) 681 Design Load SOlbs /ft z(2400Pa)loAgside — Open Circuit Voltage-V�(V) 357 301bs/ft2 (1 436 Pa) short side Short Circuit Current -Isc(A) 724 Max Series Fuse Rating: 15A Nominal operating cell temperature NOCT(800 W/m2,AM1.5, windspeed I m/s, ambient temperature 68OF(20°q. Max Reverse Current 15A CERTIFICATION LISTED UL 1703, Fire rating Type 1, Class C MECHANICAL DATA 10 year product warranty. Dimensions: 65.55 x 39-02 x 157 in (1665 x 991 x 40 mm) 25 year linear power output warranty Area: 1775ft2(1.65m2) (max. degression in performance of 0.7%p.a.). Weight: 43 lbs (19.5 kg) Note! All given specifications are subject to change without notice at anytime. REC is a leading global provider of solar energy solutions. With more than 15 years of experience, we offer sustainable, high performing products, services and investments for the solar industry. Together with our partners, we create value by providing solutions that better meet the world's growing energy needs. REC is headquartered in Norway and listed on the Oslo Stock Exchange (ticker: RECSOL). Ourl,600 employees worldwide generated revenues of USD 647 million in 2013. C U PE RTINO Oullding Department OCT 15 2015 REVIEWED FOR CODE COMPLIANCE Reviewed By: RCC W W W.Fecgroup.com / Perfect Welding / Solar Energy / Perfect Charging FRONIUS PRIMO / The future of residential solar is here - Introducing the new Fronius Primo. I'C board /Snap l�,ciier , AA'i Flag �nperl=la> ; Sncirt Grid , A¢ F n C;rn:il ��-pl,ic, n,cnl pi„c,. mu -Intim; .y.l,��n iiur,rl,itr• �De>i,ii Ready Inicn uptl„n / With power categories ranging from 3.8 kW to 8.2 kW, the transformerless Fronius Primo is the ideal compact single-phase inverter for residential applications. The sleek design is equipped with the SnaplNverter hinge mounting system which allows for lightweight, secure and convenient installation and service. / The Fronius Primo has several integrated features that set it apart from competitors including dual powerpoint trackers, high system voltage, a wide input voltage range and unrestricted use indoors and outdoors. Other standard features include a Wi-Fi* and SunSpec Modbus interface for seamless monitoring and datalogging, Arc Fault Circuit Interruption (AFCI), and Fronius's superb online and mobile platform Fronius Solar.web. The Fronius Primo is designed to adjust to future standards, offering a complete solution to code restrictions and technical innovations of tomorrow. It also works seamlessly with the Fronius Rapid Shutdown Box for a reliable NEC 2014 solution. TECHNICAL DATA FRONIUS PRIMO ENERAL DATA STANDARD WITH ALL PRIMO MODELS D _” � h,,h l u.. I. 1,11, 1 11, '1.7,, Ilii W II 47.!911,. lu=tallali<n Iudu a .., LI � t.illatlnn A,uoi,nl operalint; temperamlc rause P1 Li l P t la I ttIl J1. .1 I , -Dro-)wn-71i t=M71r- AL am urU lou I,.iinil,<d. ,i�„ 1vruui.d- ", AAAT: w. rtifi'aks onJ nq l.Ic ,vuh ,l ui.u.i, III 17312010 Ut 1198 16,, 1 = AEU IAelan -111106,,,,) ILtE1547 ,11 II LEI 4.1 "m ,4� IIFf EC. 6211. F,C I'ar1 15 A Y i NEC Artid, 6)(1 C22. 2lvo. 107.1-01 ISeptembtl 10011 ULA(01)It 1, , t 201'1 LSA 111 %1 01 k-, 1 271 i PROTECTIVE DEVICES AFCI & _'1114 NEC Rr-ady Groff rat Fatal Pl"t"non "11, rularl<n1 NI Ito, Inlcnuplcl UC reset sa pnlai ily prole�Yom STANDARD WITH ALL PRIMO MODELS n - INTERFACES STANDARD WITH ALL PRIMO MODELS Wt ti' ElboI r. I " lal wireless standard 602.11 b/g/n / Fronius Solacweb, SunSpec Modbus TCP, )SON / SunSpec Modbus RTU 6 Snpulsor 1 dit;0A Inputs'ouyn.le IBB (A >„cLcy Datalogging and/or updating vie I1SB ,v R51 22 (RI .W .,, _._,"•_..,_ ,. ce protocol Uataloygor and Avcbsncr Includrd ?he term Wi-Fi(9 is a registered trademark of the Wi-Fi Alliance. TECHNICAL DATA FRONIUS PRIMO AV Ar 6000 W 7600 I,.i.. _n INPUT DATA PRIMO 3.8-1 - PRIMO 5.0-1 PRIMO 6.0-1 PRIMO 7.6-1 PRIMO 8.2-1 SHIFTING THE LIMITS 110 1 11)1A 25.0A aL7 :1.2A Kcunnne�ided 0('PI)IA( breaker si,a laotend,d PV p,oc, ikWpl ' u 6 , lav 4 ,1 „ kw 1, y i 0% I 1 17 kW ,,,, 12 7 Lw Niz--ablelnpw.toem(MITT I/NUTT2 20 A a I,,v s,. l�4:v I�,A 1,A I' v IsA At: _,. , I"I'd ���.,,. Dc—,""t 16.7 96.9 -. 96.0 J7 0;;, CFC 6lhdency Max. erruy short circuit currant 95-U°e. 955_' 96J)'b 96.0 ",1, 96.514. Ad wimable condw Ini we M Uper.,Gug voltage angc ho V' - 6uU V God connc<li,t i, Nt t 1 votlale 600 V Fu quru,p 4.JA 1'0V iIov ILut 11:1V Total ha l monis d l,tm i Inn Inr N I ndhl ,id 1 ,rvreDC Avv( It A\%("' �l VIII V It Rai-_ \11T LUU 711)V _'IJ I -A C, ;n `t S(t I qV Liu I:,UV L� 'of NAPPI _ .,. _,.... 1-11, sent nnbcr 2617WM0 EOo '; I u ,,J OUTPUT DATA PRIMO 3.8-1 PRIMO 5.0-1 PRIMO 6.0-1 PRIMO 7.6.1 PRIMO 8.2-1 / With power categories ranging from 3.8 kW to 8.2 kW, the transformerless Fronius Primo is the ideal compact single-phase inverter for residential applications. The sleek design is equipped with the SnaplNverter hinge mounting system which allows for lightweight, secure and convenient installation and service. / The Fronius Primo has several integrated features that set it apart from competitors including dual powerpoint trackers, high system voltage, a wide input voltage range and unrestricted use indoors and outdoors. Other standard features include a Wi-Fi* and SunSpec Modbus interface for seamless monitoring and datalogging, Arc Fault Circuit Interruption (AFCI), and Fronius's superb online and mobile platform Fronius Solar.web. The Fronius Primo is designed to adjust to future standards, offering a complete solution to code restrictions and technical innovations of tomorrow. It also works seamlessly with the Fronius Rapid Shutdown Box for a reliable NEC 2014 solution. TECHNICAL DATA FRONIUS PRIMO ENERAL DATA STANDARD WITH ALL PRIMO MODELS D _” � h,,h l u.. I. 1,11, 1 11, '1.7,, Ilii W II 47.!911,. lu=tallali<n Iudu a .., LI � t.illatlnn A,uoi,nl operalint; temperamlc rause P1 Li l P t la I ttIl J1. .1 I , -Dro-)wn-71i t=M71r- AL am urU lou I,.iinil,<d. ,i�„ 1vruui.d- ", AAAT: w. rtifi'aks onJ nq l.Ic ,vuh ,l ui.u.i, III 17312010 Ut 1198 16,, 1 = AEU IAelan -111106,,,,) ILtE1547 ,11 II LEI 4.1 "m ,4� IIFf EC. 6211. F,C I'ar1 15 A Y i NEC Artid, 6)(1 C22. 2lvo. 107.1-01 ISeptembtl 10011 ULA(01)It 1, , t 201'1 LSA 111 %1 01 k-, 1 271 i PROTECTIVE DEVICES AFCI & _'1114 NEC Rr-ady Groff rat Fatal Pl"t"non "11, rularl<n1 NI Ito, Inlcnuplcl UC reset sa pnlai ily prole�Yom STANDARD WITH ALL PRIMO MODELS n - INTERFACES STANDARD WITH ALL PRIMO MODELS Wt ti' ElboI r. I " lal wireless standard 602.11 b/g/n / Fronius Solacweb, SunSpec Modbus TCP, )SON / SunSpec Modbus RTU 6 Snpulsor 1 dit;0A Inputs'ouyn.le IBB (A >„cLcy Datalogging and/or updating vie I1SB ,v R51 22 (RI .W .,, _._,"•_..,_ ,. ce protocol Uataloygor and Avcbsncr Includrd ?he term Wi-Fi(9 is a registered trademark of the Wi-Fi Alliance. CUPERTINO I3ullding Department OCT 15 2015 nowi tAmn PnR CODE COMPLIANCE Reviewed By: Perfect Welding / Solar Energy / Perfect Charging WE HAVE THREE DIVISIONS AND ONE PASSION: SHIFTING THE LIMITS OF 4ASSIBILITY4d . / Whether welding technology, photovoltaics or buttery charging technology - our goal is clearly defined: to be the innovation leader. With around 3,000 employees worldwide, we shift the limits of what's possible- our record of over 1,000 granted patents is testimony to this. While others progress step by step, we innovate in leaps and bounds. lust as we've always done. The responsible use of our resources forms the basis of our corporate policy. Further information about all Fronius products and our global sales partners and representatives can be found at w Jronius.co Kee. S 2'0.15 USA Fronius USA LLC 6797 Fronius Drive Portage, IN 46368 USA pv-support-usa@fronius.com www.fronius-usa.corn 6000 W 7600 I,.i.. _n .._-_3:A '1.'�,A 2E.SA 1653�.UA 110 1 11)1A 25.0A aL7 :1.2A Kcunnne�ided 0('PI)IA( breaker si,a 208 25 A M A 4(t A -,U A 90 A ,411 20 A it) A 35 A 40 A 45A At: _,. , 16.7 96.9 -. 96.0 J7 0;;, CFC 6lhdency Z -til 95-U°e. 955_' 96J)'b 96.0 ",1, 96.514. Ad wimable condw Ini we M AWG 14 AWG 6 God connc<li,t i, 208 / 240 Fu quru,p 6011, Total ha l monis d l,tm i Inn Inr N I I SA ;:. 0 15 I I, lel 'eap CUPERTINO I3ullding Department OCT 15 2015 nowi tAmn PnR CODE COMPLIANCE Reviewed By: Perfect Welding / Solar Energy / Perfect Charging WE HAVE THREE DIVISIONS AND ONE PASSION: SHIFTING THE LIMITS OF 4ASSIBILITY4d . / Whether welding technology, photovoltaics or buttery charging technology - our goal is clearly defined: to be the innovation leader. With around 3,000 employees worldwide, we shift the limits of what's possible- our record of over 1,000 granted patents is testimony to this. While others progress step by step, we innovate in leaps and bounds. lust as we've always done. The responsible use of our resources forms the basis of our corporate policy. Further information about all Fronius products and our global sales partners and representatives can be found at w Jronius.co Kee. S 2'0.15 USA Fronius USA LLC 6797 Fronius Drive Portage, IN 46368 USA pv-support-usa@fronius.com www.fronius-usa.corn 0 ,w, '=,SolarCity ZepSolar DWV Debris Guard for composition shingle roofs Next -Level PV Mounting Technology PHOTOVOLTAIC DWV DEBRIS GUARD\ DWV Debris Guard Construction Detail Debris Guard, close up gr 14PlPrevent blockages and keep vents open with the DWV Debris Guard. Protects against: Leaves Rain COMP11, Pine needles Insects • Snow Birds DWV Debris Guard is made of rugged 26 gauge galvanized steel. CUPERTINO Building Department '' OCT 15 2015 REVIEWED FOR CODE COMPLIANCE Reviewed By: w D-�- zepsolar.com This document does not create any express warranty by Zap Solar or about its products or services. Zap Solar's sole warranty is contained in the written product warranty for each product. The end-user documentation shipped with Zap Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of ZepSolar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. Document # 800-1677-001 Rev Date last exported: April 3, 2015 4:04 PM