Loading...
15110048-CANCELLED RECEIVED _ APP 2 5 2016 April 21, 2016 BY Dear Sir or Madam: This letter is to inquire about cancelling the permit for the following customer: Sam Ma 21811 Rifredi Court Cupertino CA, 95014 Permit# 15110048 The customer has decided to cancel their solar project with SolarCity. ddrhess:by request a refund of fees, If possible. Refund checks can be mailed directly to the following a ,ATTN: Iona V llalba SolarCity Las Vegas- `6671 S. Las Vegas Blvd Ste. 300 Las Vegas, NV 89119-3290 If you have any questions or need anything further, please let me know. Sincerely, Marjan Javanmard, Permit Coordinator (650)477-6430 miavanmardsolarcitly corn ° ` d t?3 a CI �r�i��a �y �n �t��t��, �F�LS E �f��u t�� � =��' X814 - LA,'JTY F(HO)W17-1029 t Tic 'CO { CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 21811 RIFREDI CT CONTRACTOR:SOLARCITY PERMIT NO:15110048 OWNER'S NAME: MA SAM AND DIANA 3055 CLEARVIEW WAY DATE ISSUED:11/09/2015 OV/NER'S PHONE: SAN MATEO,CA 94402 PHONE NO:(650)638-1028 LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL ❑ COMMERCIAL License Class 0-1 CgC9 Lie.# YY'19 to INSTALL(10)ROOFTOP FLUSH MOUNTED SOLAR PANELS(2.6 KW) Contractor to 0—, Date l hereby affirm that I am licenses under the provisions of Chapter 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$5500 bI have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:35716122.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct.I agree to comply with all city and county ordinances and state laws relating WIT�IIN 180 DAYS OF PERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 DAYS FROM LAST CALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the granting of this permit. Additionlg a applicant understands and will comply Issued by: Date: with all non-point source regulatits a the Cupertino Municipal Code,Section 9.18. ii RE-ROOFS: Signature Date_)K_10 All roofs shall be inspected prior to any roofing material being installed.If a roof is installed without first obtaining an inspection,I agree to remove all new materials for inspection. ❑ OWNER-BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER I,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Scc.7044, Business&Professions Code) I,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. 1 will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino uiAipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sections 25505, 33, d 25534. �� �, Section 3700 of the Labor Code,for the performance of the work for which this Owner or authorized agent: /"—' Date:A k permit is issued. I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct.I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records, granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18. Signature Date A ERNATIVE ENERGY PERMIT APPLICATION E ` AE $0,1 0`I`OR"RE AVrEt�lUE$CUPER,11110,CA 95014-S,25,5, CUPERT11 VAX 140,9)77 - .E -„3,3 �..�. 1100 PROJECT ADDRESS 9 W1 i/ ` ct aac 9 4 L 1 E-MAILOWNERNAME PHONL E- 9 ; STREET ADDRES pp 1CITY, 6430 avai'(laQ'so STATE,ZIP FAX CONTACT NAME Marjan Iavanmard PHONE— 1--F-650.477.6430 50.477. � E-MAI mjd la•GIIy.com ® V i STREET ADORES S391 Foster City Blvd CITY,STATE,ZIP Foster City, CA 94404 FAX -❑OWNER ElO%rNER-BUIIAER ElOWNERAGENT El CONTRACTOR 19 CONTRACTOR El ARCHITECT El ENGINEER El DEVELOPER ❑TENANT CONTRACTOR N � LICENSE NUMBER 888104 LICENSE TYPE C1 0 BUS."28840 24440� SolarCity corporation COMPANY NAME l Corporation E-MAIL mjavanmard@Solarcity.corn FAX STREETADDRESS391 Foster City Blvd CITY,STATE,ZIP Foster City, CA 94404 PHONE 650.477.6430 i ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS.LIC 41 COMPANY NAME E-IVIAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE USE OF LJ SFD Or Duplex ❑ Multi-Family PROJECT IN WILDLAND PROJECT IN STRUCTURE: ❑ Commercial URBAN INTERFACE AREA ❑ Yes ❑ No FLOOD ZONE ❑ Yes ❑ No OLAR PANELS ElELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING El OTHER: { FOR SOLAR PANELS NUMBER OF PANELSIUNITS: KILOWATTS(COMMERCIAL ONLY): TOTAL VALUATION Soo DESCRIPTION OF WORK Installation (_Lo ) rooftop flush mounted solar panel ( 6) kW i RECEIVED BY: By my signature below,I certify to each of the following: I am tTi piopey o er or authorized agent to act on the property owner's behalf. I have re his application and the information I have provided is correct. I have ad tlfe D cription of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to building construction. I ant ri e representatives of Cupertino to enter the above-identified property for inspection purposes. Signature ofApplicant/Agent: �^ Date: r � SUPPLEMENITAL�IN-FORMATION REQUIRED OFFICE us> o,NLY °`-°'' - ❑ OVER-TILE-COUNTER El Ir3PF ss U El STANDARD LARGE 0 MAJOR P VApp_201 1.doe revised 03116111 CITY OF CUPERTINO FEE ESTIMATOR—BUILDING DIVISION `- ADDRESS: 21811 Rifredi Ct DATE: 11/09/2015 REVIEWED BY: Phuong APN: 357-16-122 BP#: *VALUATION: 1$5,500 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration✓ Repair PRIMARY SFD or Duplex PENTAMATION SOLAR-RES USE: PERMIT TYPE: � WORK Install 10 rooftop flush mounted solar panels 2.6 K SCOPE I - _ I s' Veeh,Plan Check l'himb.P/atf£:heck Elea Plan Check blech.Perrnif Fee' Plumb.Permit Fee: Elec. Permit Fee: Other tlech.Insp. Other Plumb Insp. El Othef,Ehl (. Insp, 'Vlech Insp,I�'c:e: C'h rrtl. Trtsl�.I ec:: I lec.Insp.Fee. NOTE:This estimate does not include fees due to other Departments(i.e.Planning,Public Works,Fire,Sanitary Sewer District,School District,eta). Thesefees are based on the prelimina i4formation available and are only an estimate. Contact the Dept for addn'l info. FEE ITEMS 6Fee Resolution 11-053 E . 7/1/13,1 FEE QTUFEE MISC ITEMS Plan Check Fee: $0.00 0 # Alternative Energy System Suppl.PC Fee: � Reg. 0 OT 0.0 hrs $0.00 $236.00 IPHOTOVRES Photovoltaic System I PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp.Feer Reg. 0 OT F 0 hr $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 Construction?ay .4dininistrative Fee: 0 1 Work Without Permit? 0 Yes (F) No $0.00 Advanced Plannin Fee: $0.00 Select a Non-Residential Travel Documentation 1 ecus: Building or Structure 0 Strong Motion Fee: IBSEISMICR $0.72 Select an Administrative Item Bldg Stds Commission Fee: 1BCBSC $1.00 v SIJBT©T� $1.72 $236.00 - TSL $237.72 Revised: 10/01/2015 ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID-INTERTIED VIA A FLASHING WILL BE PAINTED TO MATCH EXTERIOR -n' `°� AC ALTERNATING CURRENT UL-LISTED POWER-CONDITIONING INVERTER. '` BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. , CONIC CONCRETE 3. A NATIONALLY-RECOGNIZED TESTING . ' -w ®� DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. RE C0BYIptW— (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING FOg Cp© - EMT ELECTRICAL METALLIC TUBING MEANS,MAY BE ENERGIZED IN THE OPEN POSITION, Reviewed BY' _. J FSB FIRE SET-BACK A SIGN WILL BE PROVIDED WARNING OF THE DAT C� GALV GALVANIZED HAZARDS PER ART. 690.17. PLANNING-OF GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY CUPERTINO HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(8). Cp.N1MUNITY DEVELOPMENT DEPARTMENT Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER BUILDING DIVISION - CUPERTINO kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR APPROVED kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E).. This set of plans and specifications MUST be kept at the MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN job site during construction. It is unlawful to make any (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY Ichangps or alterations tan same, or to deviate NEUT NEUTRAL UL LISTING. Without approval from the Building Official. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE �I .therefrom- RECEIVED I Stamping of this plan and specifications SHALL NOT OC ON CENTER UL-LISTED LOCATION PROVIDED BY THE approval of the violation PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING be held to permit.or to be an POI POINT OF INTERCONNECTION HARDWARE. of any provision of any Citjc_Or 'nav�e,or State Lavte. f�u�` c 2015 PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE 8Y - �K Gj ! SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. DATE 1�I D BY S STAINLESS STEEL PEFWIT STC STANDARD TESTING CONDITIONS TYP TYPICAL �/J oo/// k1F101 -0.C7 UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHTUj In t r� a , ` ` fPV1 COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS 'G PV4 UPLIFT CALCULATIONS LICENSE GENERAL NOTES i PV5 THREE LINE DIAGRAM ori Cutsheets Attached CA # 888104 1. ALL WORK TO BE DONE TO THE 2013 CALIFORNIA BUILDING CODE AND THE 2013 t- CALIFORNIA RESIDENTIAL CODE. _.,�• ' � � � _ � �- ; � � � � � �: LL a � 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY0� THE 2013 CALIFORNIA ELECTRIC CODE. MODULE GROUNDING METHOD: �j REV BY DATE COMMENTS AHJ: Cupertino REV A NAME DATE COMMENTS UTILITY: Pacific Gas and Electric Company " CONFIDENTIAL— THE INFORMATION HEREIN � NUMBER: J[3-9506251 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: \\\�� � CONTAINED SHALL NOT USED FOR MA, SAM MA RESIDENCE Fernando Perez SOIarCIt BENEFIT OF ANYONE EXCEPT SOLARCITY Y INC., MOUNTING SYSTEM:NOR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount.Type C 21811 RIFREDI CT 2.6 KW PV ARRAY ,, PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: C U P E R TI N 0, CA 95014 TMK OWNER. THE SALE AND USE OF THE RESPECTIVE (10) REC # REC260PEZ �� * on M teo, CA Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET REV: DATE Son Mateo, CA 94402 PERMISSION OF SOLARCITY INC. INVERTER' 65O 248-3931 PV 1 10 20 2015 T.- (650)638-1028 F.(,50)638-1029 FRONIUS Primo 3.8 ) COVER SHEET / / (888—SOL—CITY 765-2489 www.sol(3rcity.com t PITCH: 27 ARRAY PITCH:27 MP1 AZIMUTH: 180 ARRAY AZIMUTH: 180 MATERIAL: Comp Shingle STORY: 2 Stories CUPERTINO BUilding Department 4} . a NOV 0 9 2015 REVIEWED FOR CODE COMPLIANCE ReVlewed By: LEGEND (E) UTILITY METER & WARNING LABEL 3' FSB Ing INVERTER W/ INTEGRATED DC DISCO �— — —— —— ——i & WARNING LABELS ml O I © DC DISCONNECT & WARNING LABELS MI I FTC AC DISCONNECT & WARNING LABELS J m mI IU- O DC JUNCTION/COMBINER BOX & LABELS Inv LL. 1`513 1 DISTRIBUTION PANEL & LABELS AC co U i Lc LOAD CENTER & WARNING LABELS cn D O DEDICATED PV SYSTEM METER 0 STANDOFF LOCATIONS A CONDUIT RUN ON EXTERIOR O ®®® CONDUIT RUN ON INTERIOR GA /FENCE 0 HEAT PRODUCING VENTS ARE RED Front Of House INTERIOR EQUIPMENT IS DASHED L-�J TOTAL ARRAY AREA (SF): 181 SITE PLAN NScale: 1/8" = 1' TOTAL ROOF AREA (SF): 1610 w E TOTAL ARRAY AREA IS a 11.26 0 1' 8' 16' PERCENT OF TOTAL ROOF AREA I S PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN dD6 NUMBER: JB-9506251 00 MA, SAM MA RESIDENCE Fernando Perez CONTAINED SHALL NOT BE USED FOR THE ■ BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �.,��� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 21811 RIFREDI CT 2.6 KW PV ARRAY I\\ oar Ity PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATHE SALE¶AND SEEPT OF IN CONNECTION THE RESPECTIVE WITH (10)SREC # REC260PEZ CUPERTINO, CA 95014 3055 CleaMew Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME SHEER REV: DATE: San Mateo, CA 94402 PERMISSION OF SOLARCITY INC. 650 248-3931 PV 2 10 20 2015 888.80,638-1028 F89)w 638-102 FRONIUS Primo 3.8 ) SITE PLAN / / ( )—SOL—CITY(ass—lass www.salaralt.aam y a 51 � vs 10'-3" 8' 1'— (E) LBW A SIDE VIEW OF MP1 NTS `''�r����� CUPERTIN® Building Department MPI X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 72" 24" PORTRAIT 48° 20" - _ NOV 0 9 2015 ROOF AZI ARRAY AZI iso PITCH PITCH ii REVIEWED FOR CODE COMPLIANCE RAFTER 2X6 @ 24 OC STORIES: 2 C.j. 2x6 @16"OC Comp Shingle Reviewed By: PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. (4) (2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. ZEP COMP MOUNT C --- ------ ---- - -------- ------ -ZEP FLASHING CFR (3) (3) INSERT FLASHING. (E) COMP. SHINGLE (4) PLACE MOUNT. (1) (E) ROOF DECKING V (2) FINSTALL LAG BOLT WITH 5/16" DIA STAINLESS (5) G(5) SEALING WASHER. STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULESINSTALL LEVELING FOOT WITH WITH SEALING WASHER (6) BOLT & WASHERS. (2-1/2" EMBED, MIN) (E) RAFTER #_5TkNDOFF PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: JB-9506251 0 0 \�1 CONTAINED SHALL NOT USED FOR THE MA, SAM MA RESIDENCE Fernando Perez SolarCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �-.,�� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 21811 RIFREDI CT 2.6 KW PV ARRAY �1, PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: CUPERTINO, CA 95014 THE SALE AND USE OF THE RESPECTIVE (10) REC # REC260PEZPAGE NAME SHEET REV: DAIS,I` ' SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN Son3055 MateCleao, CA Way INVERTER: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. FRONIUS Primo 3.8 (650) 248-3931 STRUCTURAL VIEWS PV 3 10/20/2015 (888)—SOL—CITY(765-2489)www.solarcity.com UPLIFT CALCULATIONS 10.20.2015 `fi�� Ptd 1ystem Structural `o. ��olarClt„ ® Version#52.6 esian Software Prajo#jnformatioii&J-able",i:onfents Risk Category II PV System Type SolarGty SleekMountn x '' -� _ ERTIN® Comp Roof Comp Raof r4 ti La ers,.of ComRoofn- - - 2 ,. � 'Uiidlnc oepartment RoofSlope 27° ��,,:►,, z�" PV System Module Orientation Landscape and_Portrait ,6- Q V ) 9 2015 .'Modul- 66-_ --- PV Module Width _ _ -- _ -. 3911 .- REVi�Wr--D Fl3r.-r ODE COMPLIANCE PV Module Length Standoff Attachment Hardware Comp MountType C. Odd e ced,Gi6u id[Roof`LiveJSi b W Loads':_ Ground Snow Load pg__ 0.0 psf ASCE Table 7-1 SurroundingRoof S.nnw. _, _ , . 0 0-psf _ -- ASCE Eq_74-1 Roof Snow Over PV Modules 0.0 sf ASCE Eq:7.4-1 Wmd Design Code ASCE 7-10 WIndDesi9,9,Method;- ___ _ _ Partially/Fully Enclosed Method-_ Basic Wind Speed V 110 mph Fig 26 5 1A C . Exposure Category Roof Style Gable.Roof Fi9.3o:a-zn/e/e-sn/e Mean Raof'Herght,. _ h, _ _. 25 ft' _ _ Section-26'Z Effective Wind Area 1 Module A 17.8 sf IBC 1509.7.1 Wind;Pressure Calculation Coe tl Ients .. Wind Pressure Exposure. rvKz 0.95 Table 30.371 Topag[aphic Factor WindDrrectronahty Factor Kd 0.85 Section 26.6 1 Im oifance Factor I; NA, Velocity.Pressure qh qh=0.00256(Kz)(Kzt)(Kd)(V11,2) Equation 30.34 24.9 PSF Ext Pressure Coefficient(Up) .r GCp(Up) -0.88 F9.so 4 zn/3/c sA/e_ Ext Piessure Cpefficient Dawn;__ Gr , Down _ _ 0 45Fiye364 2A1ejc=sa/e Design Wind Pressure P p= h GC E nation 30.4-1 1pN IP)_.._-._.- Wind Pressure Down down 16.0 psf Allowable.StanddfF S acin s, - -- ]on 4u.: .. Y_D�tecti4n Max Allowable Standoff Spacing, Landscape 72" 39" Max Allowable Cantilever ; -. _ Landscape., _ 24 Standoff Confi uration Landsca a Not-Staggered ,Max Standoff_Tributary�Area-_ _.�Trib;_ PVAssembly Dead Load W-PV 3 sf Net Wind t)plrft at Standoff _..-- Tactual ,. _. _ : _ =2Z41bs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand Ca a ' ; _DCR _ - 447% Max Allowable Standoff Spacing Portrait 48" 66" Max Allowable,Cantilever ___ P,.ortralt_ _ 20 Standoff Configuration Portrait Not-Staggered Max 5tandoffTnbutaty Area.; -. Trlb•,, = 22 sf` _ PV Assembly Dead Load W-PV 3 Psf Net Wnd,UplLfE'at Standoff", - ._ _ - T-actual: _=- -. :250-lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand Ca PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: JB-9506251 0 0 CONTAINED SHALL NOT BE USED FOR THE MA, SAM MA RESIDENCE Fernando Perez SO�a�C■�ty. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: of g NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type c 21811 RIFREDI CT 2.6 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS. MODULES: C U P E R TI N O, CA 95014 r ORGANIZATION, EXCEPT IN CONNECTION WITH !' - �= 3055 Clearview Way THE SALE AND USE OF THE RESPECTIVE (10) REC # REC260PEZ PAGE NAME SHEET: REV: DATE San Mateo,CA 94402 SOLA29 PERMISSIONCITY EOFISOLARCITY INCT THE WRITTEN INVERTER: 650 248-3931 PV 4 10/20/2015 (888)(SOL,CITY(765-2489)638-1028 �wwwsolarcitycom FRONIUS Primo 3.8 ( � UPLIFT CALCULATIONS GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (N) GROUND ROD Panel Number: Inv 1: DC Ungrounded CA 888104 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:1006677528 INV 1 —(1)AFClFROInv # Primo 3.8 LABEL: A —(10)REV # REC26060 C-10 AFCI Inverter; 3800W, 240V, 97%, w/ Antenna PV Module; 260W, 236.6W PTC, MC4, 40mm, Black Frame, ZEP Enabled Underground Service Entrance INV 2 Voc: 37,8 Vpmax: 30.7 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER �E� 125A MAIN SERVICE PANEL E 10OA/2P MAIN CIRCUIT BREAKER Inverter 1 PAR (E) WIRING CUTLER—HAMMER 10OA/2P Disconnect 2 FRONIUS Primo 3.8 (E) LOADS A • L1 240V • L2 N 1 20A/2P ---- GND ------------------------------------- —EGCI --- DC+ D C+ — A I GEC �� DC- DG MPl: 1x10 B EGC— --———————————————————————————————————— — EGC I I I N I I EGCIGEC — CUPERTINO GEc ..a Building Department �..: NOV120/240V 0 �QIg SINGLE PHASE UTILITY SERVICE i`J REVIEVVED FOR CODE COMPLIANCE Reviewed By: Voc* = MAX VOC AT MIN TEMP POI (1)CUTLER-HAMMER #BR220 PV BACKFEED BREAKER (I)CUTLER-HAMMER #DG221URB /� [v ®^ Breaker, 20A/2P, 2 Spaces Disconnect; 30A, 24OVac, Non-Fusible, NEMA 3R —(1)Gro rLd Rod —(1)CUTLER -HAMMER #DG030NB H 578 x 8, Copper Ground/Neutral it; 30A, General Duty(DG) 1 AWG #10, THWN-2, Black (2)AWG#10, PV Wire, 60OV, Black Voc* =411.68 VDC Isc =9.01 ADC ® rt (1)AWG #10, THWN-2, Red O (1)AWG#10, THHN/THWN-2, Green EGC Vmp =307 VDC Imp=8.5 ADC (1)AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=15.8 AAC .. . . .. .-.(1)AWG TH.WN-2, Green EGC GEC—(1)Conduit Kit; 3 4 EMT �)Conduit Kit; 3/4'.EMT. ._.. . ✓ . . . .. . . . . . .. . . ./. . . . . . .. .. . . . . ./�. . . . . . . .. . .. . PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: JB-9506251 0 0 \0\�� � CONTAINED SHALL NOT E USED FOR THE MA, SAM MA RESIDENCE Fernando Perez ®I��C�t BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �-� � NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 21811 RIFREDI CT 2.6 KW PV ARRAY �, PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: C U P E R TI N 0, CA 95014 THE SALE AND USE OF THE RESPECTIVE (10) REC # REC260PEZ - 3055 Clearview Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME SHEER REV: DATE: T:650 San Mateo, CA 94402 PERMISSION OF SOLARCITY INC. FRONIUS Primo 3.8 (650) 248-3931 THREE LINE DIAGRAM PV 5 10/20/2015 (888)(SOL,CITY(765-2489) www.solarccitycom WARNING:PHOTOVOLTAIC POWER SOURCE • • • • • PV SYSTEM WARNING _ ••' DISCONNECT FOR ELECTRIC SHOCK HAZARD, - UTILITYOPERATION THE DC CONDUCTORS OF THIS '• - • PHOTOVOLTAIC SYSTEM ARE : UNGROUNDED AND PHOTOVOLTAIC DC MAY BE ENERGIZED - DISCONNECT "- WNR-,NI'N' ' ELECTRIC SHOCK HAZARD' •• -�_ • - • QO]N.OJTT.O.UCH,TERMINALS MAXIMUM POWER= TERMIN/1L•S©N BOTH LINE AN©) POINT•CURRENT(Imp)_A LOAD SIDES�MAtY'BE ENERGIZED: MAXIMUM,POWER- • INITiHE OPQNI POS,•,ITION. POINT.VOLTAGE(•Vmp)-� '' MAXIMUM SYSTEM VOLTAGE(Voc)_V SHORT.- CIRCUIT CURRENT(Isc)-A .•- • • WARNING '• INVERTER OUTPUT C.ONNEC:TION /� - • DO REL•OCAT'E WA.RN•1:NG THIS ODEVCURRENT � - DEVICE ELECTRICAL SHOCKHAZARDI DO NOT TOUCH TERMINALS •' TERMINALS ON:BOTH LINE AND LOAD'SIDES.MAYBE ENERGIZED• • _•_ _ IMTHE.OPEN POSITION "•- • • DC VOLTAGE IS PHOTQVOLTAI'C POINT OF -• ALWAYS,PRESENT WHEN INTERCONNECTION, SOLAR MODULES:ARE' WARNING ELECTRIC SHOCK - EXPOSED.TO SUNLIGHTHAZARD DO NOT TOUCH '' •' - TERMINALS,.TERMINALS-ON' ROTH THE LINE AND,LOAD'SIDE MAY BE ENERGIZED LN THE OPEN • POSITION.FOR SERVICE _ • _ DE-ENERGIZE BATH,SOURCE VV •�•��RNI,N�G AND M;4IN;BR�EAKER. PV P01NER:SOURCE oil- MAXIMUM-AC. ELECTRIC$H0M HAZARD •. OPERATING+CURRENT -,`A IFAGROUND FAULT IS INDICATED NORMALLY GROUNDED MAXIMUM.AC V ; CONDUCTORS MAYBE OPERATING VOLTAGE _ UNGROUNDED'AND ENERGIZED' • CAUTI.ON ' P H'OTOV:O'LTAI'C AC '• PWOTQVOLTAIC SYSTEM CCITBKFEDDISCONNECT AC '- ••'•' • ' ' ' - • MAXIMUM AC A - CAUThON• OPERATING,CURRENT -_ ' ' •,• -- �•�- DUAL POWER SOUR.C.E '- ••- WAXIMUM.AG.' •. , SECOND;SOURCE IS� OPERATING VOLTAGE -"•V PHOTOVOL•TAIC.SYSTEM • • • • .• . • �• 3055 Clearview Way San Mateo,CA 94402 T:(650)638-1028 �• •� •. Label Set (888)-SOL-CITY(765-2489)www.solarcity.com i "SolafCit Ze SoLar Next-Level PV Mounting Technology '� $O�i3fClty ZepSoLar Next-Level PV Mounting Technology Zep system Components for composition shingle roofs Up-roof I . Ground Zep Intertoek ,Key sii. __,. Leveling Foot J—�� i CUPERTINO J Zcp Gompatiblc RV Modulc _ Uilding Department Zc _ - P Graavc - � �r.2t�Y r..s Roof Atm chment NOV0 9 2015 ---- Array Skirt Rll_--vi�-1rvED -OR CODE: connPLi COMPLIANCE CE Re ed By. N�oo-par�el� Description 1� / v PV mounting solution for composition shingle roofs ACpMppS�� Works with all Zep Compatible Modules • Auto bonding UL-listed hardware creates structual and electrical bond • Zep System has a UL 1703 Class"A"Fire Rating when installed using U` LISTED modules from any manufacturer certified as"Type 1"or"Type 2" Comp Mount Interlock Leveling Foot Part No.850-1382 Part No.850-1388 Part No.850-1397 Listed to UL 2582& Listed to UL 2703 Listed to UL 2703 Specifications Mounting Block to UL 2703 El r • Designed for pitched roofs st•o Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards Q� • Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467 f Zep System bonding products are UL listed to UL 2703 ® „ • Engineered for spans up to 72"and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices Ground Zep Array Skirt,Grip,End Caps DC Wire Clip • Attachment method UL listed to UL 2582 for Wind Driven Rain Part No.850-1172 Part Nos.500-0113, Part No.850-1448 Listed to UL 2703 and 850-1421,850-1460, Listed UL 1565 ETL listed to UL 467 850-1467 zepsolar.com zepsolar.com Listed to UL 2703 This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of Zep Solar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. responsible for verifying the suitability of Zep Solar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. 02 27 15 ZS for Comp Shingle Cutsheet Rev 04.pdf Page: 1 of 2 02 27 15 ZS for Comp Shingle Cutsheet Rev 04.pdf Page: 2 of 2 Grp ENERGIZING LIFE TOG'ETH'ER RE C HIGH PERFORMANCE SOLAR PANELS 1 5 'k RE[ PEAK 'MSS,. r•�w \� 1 47.24 0.4 ENERGY 4',.-, k .�. l` ''•.,'r,' 1 TEMPERATURE RATINGS L[IN I K It 'SY '� i• ti� . • 1 ■ %y .i'x. \ .• .• . 1 1 EC Peak Energy Z-Link Series solar panels are •perfect choice for building 3 r s ELECTRICAL DATA 'STC y, a « rw @ REC260PEZ. GENERALI)A -solar •t combine longlasting `s product quality with reliable poweroutput., r1 rt, r iry A « it • $.�; REC combines high quality design and 9r'. l i= 6J • 1 high- performance • • panels with i r. f ,d"���fr lr�d' ,� ' G ,,` � �f;`/-rt r '�� 1 • ••• uncompromising quality s v.G3'r Yi.`-r." 'moi w .• c d._,;n`£F ,� - 111• . . ,� .. /j� r �,I�:a �r`f/{'!,', ��<•. � ��!f!+' �'_} ELECTRICAL DATA@NO[T RECMAXIMUM:RATINGS • 1 '.♦tyyrj �� �Yy'7 /.:�,f��,��t/��� •1 • 111 ifr�:r�r.1'' w/<�✓ '�r�fi��+wr�,.frrJ t✓.;�,.�/ .s . \• .. 1 . r 1 1• . .- MOhEPOWER COMPATIBLEWITH Yr%,/I ''Pr'✓fi.%�t.. /rfr'"t J✓ /�i/' sem✓" tr �. ffllqzNX :11 �J•✓rr�� f�E'� rf f�/,��li �/i�r3. r�/J A .�"yF. j;y� y � ,<r /��` r JI�iJ/r'r�fi% 4r♦ S"� •''✓ °�ff'� i J '. CERTIFICATION WARRANTY MECHANICAL.DATA �%� � `ly"•II•+�JI iif'e �•i`�t:,�� r j�f"r�> J. x', .,fWY 'I�r�`r/t����" �/J'✓j f�! r sd/.�{�tJ'♦r�� i� r�-r 1 1 •• \ • •1 '1 id 1•, t %+//f'f,'f/✓ fir-,- If ! i' r r USIMPORT EASYTO "' Jf{,fr -3'' ir"^' ✓/,/,,�/� v.'1�1� `5 ' • t� f ,J✓¢ /f/v✓•' `5w rt/iH I'tJ lfr � T'� �'�%. • .-. • •. .. 1 ... T/f' > +r/�i// �ie�/ G Aril rr,f✓ 1y/ j�I+/�fIII/RX�r;;' tiJr f � '�f�}•L�'%/'fJ,�r.-��f � f�a% .,y r �rJ I j ��j/0' •-.Fe:Y ,j�G/y'/�/, .�fi.j �'J f1'r1�'A'i/�,r� ./.}Jryu ` y�,:�./}:€ yf„ .�t♦r; r',,'lnr/ •. • •• / .-`s :' :.�!� r _Jf-. 1'} '/j+,r'. .�% t �� �I,+ I,��1fiiJ,o r✓ f.� =%f�f,�, /(flf� 5A �j< r. -, j. �. �, lr' ,f�. s�J. �� � � "'��, r �/.. r�� �/J,ff1f '��_f�J i.f'�f;°�r:��.•� r � 3 ;r��:f •\ _ •/ • \ • •11 / > ✓fi.%"'fii✓l. ,rr ill, •'f J,i/ / •' i ,.r.fl ';/f1.,lir '-1 Ir'. �` .,✓� r: •.• • ••�•' .• • ,.. ✓ .rJ. ./ !', s iJ.iti•i. t /r .!/ -v / r.' r • • 1•. 1�" r✓�~f1l�f'�•I�tX.r:`'/�f}`��r'.•?•�'j',✓�/- , �- '��tf �rri� rw'✓ ��� r,S'r/ •J,rr? a� J `♦i G�,,1,a v#d... ;! ,: frJdi'.!'s'. fi9✓! 's' 'jf,.v tJO rri f,1 %•'`,rrj ,•`f''*f.,.'s� �'' r,rJ/�'• rdr.J'l'.A ,,���� J+r ! rt/r, �✓ ♦JA"��� 'r/J� rf �'I` r!�` �f`,�,�// ♦;I,! �`fi' 'r' �z'r J �`'F j/�/ . '�' / �.'`f.5; '« '��" �f�r/f�• jr�'J.r r;�.y J�' / ,+/ "�! � j •�`✓!l '% r.� ♦ 4f,' }"'� rr fA rr ��t��ir �r 4����4 ,tr'r�'`;1 ''?/' f�r a //,/ .'��{�r J �- '$:r���/t r'/rj� rl�rr.+G�✓fjf f'r!.� y.' ,Ifi� J ,•t!!�t ✓�l C'<.Jw.r�JS';//�i• ✓rf�.��^J ,"Jf/f ,f V 'r �J�'r,rr��� ;�y�i��✓�r� ��/' •f/�/r�.fr�'� Mfr !':I t f �,.s! 7/ ♦��j y, /; r, "i.' .s,✓,`/'.�J'�J�-� r r,,. �,�.✓'o +""//d r.r;!�✓', ''"'f�ra J�' +!/' f "✓ / r f '%;''fJJ %'. j/�',r,/fit""'"'.�''f/irrw'f�tl ,r/l.. '} G '! =>7'"9 rT%4,'�f'°'a, -'- v�y^'J� ✓•,.!d i,�r !'f':F+,r� r'��r,''�' �`.t�+`,�� ✓ r/ '�f.�,/ � � f r�" /'.r' ✓r 2 �'� �/ � if' `�. �i 4'�{%..r�' r/<>. �! f T.X` �. �+/ ^:w �. +,��• .'r %� � � � �!! / 4�r�A ��,� rr� 1 � /. � �/ w� J L/f*�i � .y lr/' �.%rj'♦ .c1�J tri/' J t }d� 1 ✓ e Jr r J r ,/ � '�ti�'f;,.'s. ,ef � /Jff d 1 •' J. y, n /e.t+rr. �f ,/ r�. d �•`rJ�✓ r r r'f !' +}�J F r♦ /" � /� � � /! '` r�l.�i "r��//I /,+/'r,. r t JS' E ;I✓,/,i ;J. �,f. rA,�{r. � rr,'1r�fiv h�r�+r lY�rj,/ry���* "�/'P�r a� � �' %d�J/.`'f �% J �� g �'Jy%i'��f�tr,i y, ffi/ �/i',�j/b�.GJJ'�;�,gJ�b'F7 / yam` F�Ji.��%f,fi+ �%'%d re r ua "•<•'r.^•a 4's�"`�i` � �. i�' ��J/f r;f"�� �f.�r,'/h'/�,r/ /.. r✓�r+r r rrff,�,.'/r,,1,,�/,« i ♦ * .�r l� r .!' ,.rrrFd � fk 1$. � � 1% � Y' t✓�.r f' r'.J / ' 1. �>,. rT tf�:f, f. JJ.;d,,/. Y.�r/ r�<..w f a" >,� _•:'j '� �r''" ✓r 4f�/' 'T��/ �t'r,r;f'fir.Jr y.r'!r`- ''ry ` i�. /f�/f/J•�1.'f�.,a r ."..fr r, •♦: �f ✓f�/ d��,f ,�.,.+.f� rl�.�� i.�r+ f.f'., � i%�/� �� %` rFf/�/ + 1 f;.r, ,'ri.:. 'r,f h•�.�r �l f>�fj 4 �'.'J ,J i..�.r_ /rf/rI,�dr f,J•�?';f-..r'-�!-- �<j r/�4.;'�r„'.rx" "�!. l .�l{ � ��i, '/� � � � � r,�r�^ ���s ✓� 'YJJ�J f • � ,r,r �,�/ q •/ J fA/J �, r0�fj Ir>,r f,., Ji ../,.. € ' ''Y ,/i rr ��°J' �J �t, � •rr !� _/J�r� >��/!. ��ff: ��ft: r G.:}1.:♦' �� �O.`�f!/I�' '�r�ry � ;:% r`? �:! � /r, ds�%•. r,,:./.. r. rl Jle., .�+ lr,. r/ f ./ rf .+J <; Jri, r/.♦dd.l1r.. /Perfect Welding/Solar Energy/Perfect Charging TECHNICAL DATA FRONIUS PRIMO i SHIFTING THE LIMITS INPUT DATA PRIMO 3.8-1 PRIMO 5.0-1 PRIMO 6.0-1 PRIMO 7.6-1 PRIMO 8.2-1 Recommended PV power(kWp) 3.0-6.0 kW X4.0-7.8 kW 4.8-9.3 kW `6.1-11.7 kW 6.6-12.7 kW FRONIUS PRIMO - --- - M...wattle input currcnt(MPPTIMPYT j_ _ 18ALIA -- - IS'A118, /18 AA /1S I8 AA 18A/18A Total max.DC current 36 A Ala.array short circuit current ""----- -------�--_---- 2x 22.5 A - - - ------ ------ /The future of residential solar is here-Introducing the new Fronius Primo. Operating voltage rang_ _=8 _- _ __- __ 0 V'-600 V -- - LN7ax..iinpuivaltagc 600V `Nominal input voltage 410v -120 V 420V 420 V 420V • Admissible conductor size DC -- - ----�-AWG 14...AWG b' i-- --- -_- MPP Voltage Range 200 180 V 240-480 V 240 480 V 250-480 V 270-480 V g" �Jm I Number-1<(YPT 2 �® 'Starting with serial number 26170960;before serial number:150 V Cti/PC board /SiiaplNvcrtcr 'n /Wt-Fip /SuperFlcx /Smart Grid - /An:Faith Circul. t�rcplaceincin process n ---t system i note face •., Dcsngn - Ready Int cmnpno i _ OUTPUT DATA PRIMO 3.8-1 I PRIMO 5.0-1 PRIMO 6.0-1 PRIMO 7.6-1 PRIMO 8.2-1 /With power categories ranging from 3.8 kW to 8.2 kW, the transformerless Fronius Primo is the ideal compact Max.output power_ 200 3800 w 5000 W-` 6000 W 7600W 7900 W single-phase inverter for residential applications.The sleek design is equipped with the Sna INverter hinge mounting 3800W 5000 w-----"-6000,----- -"- coo w - b200 w Max.continuous output current 208 18.3 A 24.0 A 28.8 A 36.5 A 38.0 A system which allows for lightweight,secure and convenient installation and service. F ---- _ Z40- 15.8.A _.20.8.A'. - 25:0'A 3.1.7A .34.2 A: Recommended OCPD/AC breaker size 208 25A 30 A 40 A 50 A 50A /The Fronius Primo has several integrated features that set it apart from competitors including dual powerpoint x10i 20A .. r aaA 35 A �; fan 45n - trackers,high system voltage,a wide input voltage range and unrestricted use indoors and outdoors.Other standard Max.Efficiency 96.7% 96.9 i 96.9% 96.9% 97.0 r features include a Wi-Fi*and SunSpec Modbus interface for seamless monitoring and datalogging,Arc Fault CircuitcIL,_CEi�ienry 24th y5.0oo Interruption (AFCI), and Fronius's superb online and mobile platform Fronius Solar.web. The Fronius Primo is Admissableconductor sizcAC -Y - _ -AWG 14-AwG6 --- Grid connection- ,dog/?40. designed to adjust to future standards,offering a complete.solution to code restrictions and technical innovations of _ -- _ Frequency 60 Hz tomorrow.It also works seamless) with the Fronius Rapid Shutdown Box for a reliable NEC 2014 solution. -- - _-- y A I_Total harmonic distortion - --_ <5.0l Power factor(cos Tac,,) - 0.85-1 ind./cap TECHNICAL DATA FRONIUS PRIMO I GENERAL DATA :I STANDARD WITH ALL PRIMO.MODELS Dimensions(width x height x depth) 16.9 x 24.7 x 8.1 in. I.We ght --r- - � 47.29 lb::NEMA 4X - �t ,< .I PERT N Degree of protector 1WnJlld Inverter topology Transfomcrlcss ing Department IiCooling -� variable speed fart,.. 'F. - < Installation Indoor and outdoor installation �� Q 9 2-015Ambntn at Ic,n craturn rani c 70 137`F-00...s55`C ""')y L en2r -_p- ( _J Permitted humidity_ _ 0-100% I DC Connection temm�ils ^~'I 4t DC+and 4x DC scr.iv t ,ils to b sgbd si a 1 1 jhny stranded) r hunimiru isobd(strap iul). E (t,LE C -0,R ,,,,r C 1t t �ACc connection terminals 5 e term als 1.6 AWG REVI /�.�� ,-�,R CODE COMPLIANCE Cenificatns-I ct n pitanc v th standards •UL 1741-2070 1)L1998(for functions:AFCI and isolation monitoring),IEEE 15472003.1E EE 1 47.1,2003,ANSI/IEEE C62.41,.FCC., Iaet 15:A&B,NEC'A tele 690'C22 2No 107101(ScptcTnibt 2001);,1/L1(99B.1s"uc2 2013 CSA TIL M-07 Issue t 2013 RevieWed By. PROTECTIVE DEVICES _ STANDARD WITH ALL PRIMO MODELS AFCI&2014 NEC Ready _ _ _---_-- -- Yes Ground Fault Protection w th Isolation.Mo sitar- r- lmcrrtrptcr - _Yes DC disconnect Yes - /Perfect Welding/Solar Energy/Perfect Charging llC r crsc.pol-_tY prolc�l do . Yc, WE HAVE THREE DIVISIONS AND ONE PASSION:SHIFTING THE LIMITS OF rOSSIBILITY. /Whether welding technology, hotovolkaics or battery charging technology ) defined:to be the innovation leader.Willi around !INTERFACES STANDARD WITH ALL PRIMO MODELS ° 1 D ar S a tecgY-our goal is clearly 3,000 employees worldwide,we shift the limits of what's possible-our record of over 1,000 granted patents is testimony to this.While others progress Wi-Fi'/EthcmcVScrial Wireless standard 802.11 b/g/n/Fronius Solacweb,SunSpec Modbus TCP,JSON/SurnSpee Modbus RTIJ step by step,we innovate in leaps and bounds.Just as we've always done.The responsible use of our resources forms the basis of our corporate policy. G inputs� Or o.digital inputs/oulpul5 -„�J��� External relay controls USB(A socket) _ Datalogging and/or updalingvia USB !� �w- Further information about all Fronius products and our global sales partners and representatives can be found at www.fronius.com L2x RS422.(AJ4 socket) •r Fro n us Solar•Nct interface protocol -, Da S42crand WcbscrvcrV-_. _-----Included _--_ "The term Wi-Fi iQ is a registered trademark of die Wi-Fi Alliance. Fronius USA LLC 6797 Fronius Drive Portage,IN 46368 USA Rev.5,20.15 USA pv-support-usa@fronius.com www.fronius-usa.com 6olarClty I ZepSolar Next-Level PV Mounting Technology DWV Debris Guard for composition shingle roofs PHOTOVOLTAIC MODULE DWV DEBRIS GUARD COMP ROOF MOUNT COMP ROOF O DWV Debris Guard Construction Detail Debris Guard,close up �OOMP4T, Prevent blockages and keep vents open with the DWV Debris Guard. Protects against: � <��: C 4.►P E RTI IV O m, Leaves Rain Duilding Department OMPAF, • Pine needles Insects • Snow Birds ?; .. --�- � a o 2015 DWV Debris Guard is made of rugged 26 gauge galvanized steel. REVIEWED FOR CODE COMPLIANCE Reviewed Ey: W4 C_. zepsolar.com This document does not create any express warranty by Zep Solar or about its products or services.Zap Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. Document#800-1677-001 Rev A Date last exported:April 3,2015 4:04 PM