15100114I CITY OF CUPERTINO BUILDING PERMIT I
I BUILDING ADDRESS: 21960 MCCLELLAN RD CONTRACTOR: SOLARCITY PERMIT NO: 15100114
I OWNER'S NAME: YKARI CHAVES 13055 CLEARVIEW WAY I DATE ISSUED: 10/14/2015 I
OWNER'S PHONE: 4082524553 1 SAN MATEO, CA 94402 1 PHONE NO: (650) 638-1028 1
LICENSED CONTRACTOR'S DECLARATION
License Class0_ 02(Lic. # 119i
Contractor i) 10,x` f ") Date to i Ll /L)
I hereby affirm that I am licensed under the provisions of Chapter 9
(commencing with Section 7000) of Division 3 of the Business & Professions
Code and that my license is in full force and effect.
JOB DESCRIPTION: RESIDENTIAL ❑ COMMERCIAL Q
INSTALLATION 15 ROOFTOP FLUSH MOUNTED SOLAR PANEL
(3.9KW)
hereby affirm under penalty of perjury one of the following two declarations: Sq. Ft Floor Area:
I have and will maintain a certificate of consent to self --insure for Worker's
Compensation, as provided for by Section 3700 of the Labor Code, for the APN Number: 35608033.00
performance of the work for which this permit is issued.
I have and will maintain Worker's Compensation Insurance, as provided for by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued.
APPLICANT CERTIFICATION
I certify that I have read this application and state that the above information is
correct. I agree to comply with all city and county ordinances and state laws relating
to building construction, and hereby authorize representatives of this city to enter
upon the above mentioned property for inspection purposes. (We) agree to save
indemnify and keep harmless the City of Cupertino against liabilities, judgments,
costs, and expenses which may acctue against said City in consequence of the
granting of this permit. Additionally,applicant understands and will comply with
all non -point source regulation aper tli Cupertino Municipal Code, Section 9.18.
Signature f Date (�
1-, m
1 OWNER -BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for one of
the following two reasons:
1. I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for
sale (Sec.7044, Business & Professions Code)
2. I, as owner of the property, am exclusively contracting with licensed contractors to
construct the project (Sec.7044, Business & Professions Code).
I hereby affirm under penalty of perjury one of the following three declarations:
t. I have and will maintain a Certificate of Consent to self -insure for Worker's
Compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
2. I have and will maintain Worker's Compensation Insurance, as provided for by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued.
s. I certify that in the performance of the work for which this permit is issued, I shall
not employ any person in any manner so as to become subject to the Worker's
Compensation laws of California. If, after making this certificate of exemption, I
become subject to the Worker's Compensation provisions of the Labor Code, I
must forthwith comply with such provisions or this permit shall be deemed
revoked.
APPLICANT CERTIFICATION
I certify that I have read this application and state that the above information is
correct. I agree to comply with all city and county ordinances and state laws relating
to building construction, and hereby authorize representatives of this city to enter
upon the above mentioned property for inspection purposes. (We) agree to save
indemnify and keep harmless the City of Cupertino against liabilities, judgments,
costs, and expenses which may accrue against said City in consequence of the
granting of this permit. Additionally, the applicant understands and will comply with
all non -point source regulations per the Cupertino Municipal Code, Section 9.18.
Signature Date
Valuation: $8500
Occupancy Type:
PERMIT EXPIRES IF WORK IS NOT STARTED
WITHIN 180 DAYS OF PERMIT ISSUANCE OR
180 DAYS AST CALLED _2�INSPECTION.
Issued by: .2Date• /
RE -ROOFS:
All roofs shall be inspected prior to any roofing material being installed. If a roof is
installed without first obtaining an inspection, I agree to remove all new materials for
inspection.
Signature of Applicant: Date:
ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER
HAZARDOUS MATERIALS DISCLOSURE
I have read the hazardous materials requirements under Chapter 6.95 of the
California Health & Safety Code, Sections 25505, 25533, and 25534. Lwill maintain
compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health &
Safety Code, Section 25532(a) should I store or handle hazardous material.
Additionally, should I use equipment or devices which emit hazardous air
contaminants as defined by the Bay Area Air Quality Management District I will
maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the
Health & Safety Cod -Sects 25505, 25533, and 25534.
Owner or ut a r t:
Date:
z
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of work's
for which this permit is issued (Sec. 3097, Civ C.)
Lender's Name
Lender's Address
ARCHITECT'S DECLARATION
I understand my plans shall be used as public records.
Licensed Professional
UM Ev�
A
`IR s s _.
a-IUPERTINO
PROJECT ADDRESS �$ / ®� �yfl F� I C_ CL 6r,) Pr`-� APN k 0
OWNER NAMEPHONE IBJ 4� E-MAIL
r �d
STREET ADDRESS r CITY, STATE, ZIP FAX
t�U.V, Ck. � -i M fr 0 13 5o i
CONTACT NAME Marian Javanmard PHGNE650.477.6430 i E-MAILmjavanmard@solarcity.com
STREETADDREss391 Foster City Blvd CITY, STATE; ZIP Foster City, C/6 94404 FAX
❑ OWNER ❑ owNt ER -BUILDER ❑ OWNER AGENT ❑ CONTRACTOR ® CONTRACTOR AGENT ❑ ARCIffrECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT
CONTRACTOR NAME
SolarCity Corporation
LICENSE NUMBER
88F104
LICENSE TYPE
C10
BUS. LIC k
28640
COMPANY NAMESolarCity Corporation
F
E-MAIL mjavanmaard@solarcity.com
FAX
STREETADDREss391 Foster City Blvd
U
CITY, STATE, ZIP Foster City, CA 94404
PH0N`650.477.6430
ARCHITECT/ENG(NEER NAME
LICENSE NUMBER
BUS. LIC
COMPANY NAME
E-MAIL.
FAX
STREET ADDRESS
It
USE OF Ed SFD Or Duplex ❑ Multi -Family
STRUCTURE: ❑ Commercial
CITY, STATE, ZIP PHONE'
PROJECT IN WILDLAND PROJECT IN
URBAN INTERFACE AREA ❑ Yes ❑ No FLOOD ZONE ❑ Yes ❑ No
SOLAR PANELS
❑ ELECTRIC VEHICLE CHARGING STATION
❑ SOLAR WATER HEATING
❑ OTHER:
FOR SOLAR PA,VELS. NUMBER OF PANELS/UNITS: � 5 KILOWATTS (COMMERCIAL ONLY): j -'I
DESCRIPTION OF WORK
- Installation ( 15 ) rooftop flush mounted solar panel (3-. ) kW
By my signature below, I certify to each of the following: I am
application and the information I have provided is correct. I ha -V
ordinances and state laws relating to building construction. I au
Signature of Applicant/Agent:
or authorized agent to act on the property o er's be al£ I have read this
on of Work and verify it is accurate. I agree y with all applicable local
es of Cupertino to enter the above -identified property for inspection purposes.
Date: I r) 14 /1-5
.TION REQUIRED
OFFICE USE ONLY
❑ OVER-TH&COUNTER
F
f
.J
❑ EAPRESS
U
❑ STANDARD
U
2
❑ LARGE
c,
❑ MAJOR
PYApp_2011.doc revised 03/16/11
CITY OF CUPERTINO
FEE ESTIMATOR — BUILDING DIVISION
ADDRESS: 21960 MCCELLAN RD DATE: 10/14/2015 REVIEWED BY: PHUONG
APN 356-08-033 BP#: VALUATION: 1$8,500
*PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair
PRIMARY SFD or Duplex PENTAMATION SOLAR -RES
USE: PERMIT TYPE:
WORK INSTALLATION 15 ROOFTOP FLUSH MOUNTED SOLAR PANEL 3.9kw
SCOPE
,,Tech. i'lan (3,7eck
FEE
d'fxfO. 1 loo Ch
Elec. ,P/17;i Check
I
hi(?f li.
1'e ft7 l 7 Li.':
$0.00
= #
$236.00
7'111 ti?J. N: if Fee:
Suppl. PC Fee: Reg. 0 OT 1
I l,le c Permil Fee:
011lier AA --ch. Imp. I I I I o . I I I
C,rhet l u��:<i Irr:s; C)fhe?•
. lech. fayl-'. 14*ee: ( phulib. Tris. I Ins'Fee:
NOTE: This estimate does not include fees due to other Departments r.e. Planninz, Public Works, Fire, Sanitary Sewer District, School
rl:ctv:nt .#, 1 7%— 'r .,......., 1--1 -- f1... „1:..... 1-nntnrt tho I)vnt fpr addn'I info_
FEE ITEMS (Fee Resolution 11-053 Ef. . 711./13)
FEE
QTY/FEE
MISC ITEMS
Plan Check Fee:
$0.00
= #
$236.00
Alternative Energy System
IPHQTOVRES Photovoltaic System
Suppl. PC Fee: Reg. 0 OT 1
0. 01
hrs
$0.00
PME Plan Check:
$0.00
Permit Fee:
$0.00
Suppl. Insp. Fee:19 Reg. 0 OT
0,0
hrs
$0.00
PME Unit Fee:
$0.00
PME Permit Fee:
$0.00
(1017shr vtiopz
Achr ni5'tratile Fee:
E)
Work Without Permit? 0 Yes (j) No
$0.00
Advanced Planning Fee:
$0.00
Select a Non -Residential
Building or Structure
G
A
frUvel T�ocu me'nialion fees
Strong Motion Fee: IBSEISMICR
$1.11
Select an Administrative Item
Bldg Stds Commission Fee: IBCBSC
$1.00
SI7BTOTALS=
$2.11
$236.00
TO�ALTET::
$238.11
Revised: 1U/U1izu'5
ABBREVIATIONS ELECTRICAL NOTES I JURISDICTION NOTES
A AMPERE
AC ALTERNATING CURRENT
BLDG BUILDING
CONC CONCRETE
DC DIRECT CURRENT
EGC EQUIPMENT GROUNDING CONDUCTOR
(E) EXISTING
EMT ELECTRICAL METALLIC TUBING
FSB FIRE SET -BACK
GALV GALVANIZED
GEC GROUNDING ELECTRODE CONDUCTOR
GND GROUND
HDG HOT DIPPED GALVANIZED
I CURRENT
Imp CURRENT AT MAX POWER
Isc SHORT CIRCUIT CURRENT
kVA KILOVOLT AMPERE
kW KILOWATT
LBW LOAD BEARING WALL
MIN MINIMUM
(N) NEW
NEUT NEUTRAL
NTS NOT TO SCALE
OC ON CENTER
PL PROPERTY LINE
POI POINT OF INTERCONNECTION
PV PHOTOVOLTAIC
SCH SCHEDULE
S STAINLESS STEEL
STC STANDARD TESTING CONDITIONS
TYP TYPICAL
UPS UNINTERRUPTIBLE POWER SUPPLY
V VOLT
Vmp VOLTAGE AT MAX POWER
Voc VOLTAGE AT OPEN CIRCUIT
W WATT
3R NEMA 3R, RAINTIGHT
1. THIS SYSTEM IS GRID-INTERTIED VIA A
UL -LISTED f OWER-COND!T!ONING INVFRTFR.
2. THIS SYSTEM HAS NO BATTERIES, NO UPS.
3. A NATIONALLY -RECOGNIZED TESTING
LABORATORY SHALL LIST ALL EQUIPMENT IN
COMPLIANCE WITH ART. 110.3.
4. WHERE ALL TERMINALS OF THE DISCONNECTING
MEANS MAY BE ENERGIZED IN THE OPEN POSITION,
A SIGN WILL BE PROVIDED WARNING OF THE
HAZARDS PER ART. 690.17.
5. EACH UNGROUNDED CONDUCTOR OF THE
MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY
PHASE AND SYSTEM PER ART. 210.5.
6. CIRCUITS OVER 250V TO GROUND SHALL
COMPLY WITH ART. 250.97, 250.92(B).
7. DC CONDUCTORS EITHER DO NOT ENTER
BUILDING OR ARE RUN IN METALLIC RACEWAYS OR
ENCLOSURES TO THE FIRST ACCESSIBLE DC
DISCONNECTING MEANS PER ART. 690.31(E).
8. ALL WIRES SHALL BE PROVIDED WITH STRAIN
RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY
UL LISTING.
9. MODULE FRAMES SHALL BE GROUNDED AT THE
UL -LISTED LOCATION PROVIDED BY THE
MANUFACTURER USING UL LISTED GROUNDING
HARDWARE.
10. MODULE FRAMES, RAIL, AND POSTS SHALL BE
BONDED WITH EQUIPMENT GROUND CONDUCTORS.
LICENSE GENERAL NOTES
CA # 888104 1. ALL WORK TO BE DONE TO THE 2013
C-10 CALIFORNIA BUILDING CODE AND THE 2013
CALIFORNIA RESIDENTIAL CODE.
2. ALL ELECTRICAL WORK SHALL COMPLY WITH
THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY
THE 2013 CALIFORNIA ELECTRIC CODE.
MODULE GROUNDING METHOD: ZEP SOLAR I
AHJ: Cupertino
FLASHING WILL BE PAINTED TO MATCH EXTERIOR
UTILITY: Pacific Gas and Electric Company
•�
JB-9506224 00 `''IQ'E"
CONFIDENTIAL —THE INFORMATION HEREIN [INVERTER:
NUMBER: CHAVEZ, YUKARI
CONTAINED SHALL NOT BE USED FOR THE
BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NTING SYSTEM:
NOR SHALL IT BE DISCLOSED IN WHOLE OR INultiple Mounting Hardware Types 21960 MCCLELLAN ROAD
PART TO OTHERS OUTSIDE THE RECIPIENTS
ORGANIZATION, EXCEPT IN CONNECTION WITH ULES: CUPERTINO, C A 95014
THE SALE AND USE OF THE RESPECTIVE 5) REC # REC260PEZSOLAR�:
PERMISSION
EQUIPMENT, WITHOUT THE WRITTEN 4082524553
PERMISSION of soLARCITY lNc.LAREDGE # SE380OA-US-ZB-U
— I CUPERTINO
I Building Depatnent
w .0 I
QCT 1 4 2015
-ZEVIEVVED FOR CODE COMPLIANCE
Reviewed By: —,
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING DIVISION - CUPERTINO
APPROVED
This set of plans and specifications MUST be kept at the
job site during construction. It is unlawful to make any
changes or alterations on same, or to deviate
therefrom, without approval from the Building Official.
The Stamping of this plan and specifications SHALL NOT
be held to permit or to be an approval of the violation
any provi ' C
B y
Y ` ity Ordinance or State Law.
Ei
DATE U —
PERMIT # _ V
VICINITY MAP
0
DESCRIPTION:
CHAVEZ RESIDENCE
3.9 KW PV ARRAY
TMK OWNER:
PACE NAME:
COVER SHEET
PIAT P NS C ECKED h y.
DATE /0 /' o ls
PLANNING DEPT
CUPERTINO
INDEX
x-11 PV1 COVER SHEET
PV2 SITE PLAN
PV3 STRUCTURAL VIEWS
"�. PV4 UPLIFT CALCULATIONS
f iI PV5 THREE LINE DIAGRAM
iII :- Cutsheets Attached
a
O
V
W
U
LL
REV BY DATE COMMENTS
REV A NAME DATE COMMENTS
t ■ s s
DESIGN:
D. ew Flerchinger \\I,;SOIarCit
^� v
J V 3055 Cleorview Way
SHEET: REV: DATE San Mateo, CA 94402
T:(650) 638-1028 F:(650) 638-1029
PV 1 10/13/2015 (888)—SOL—CITY (765-2489) www.solarcity.com
Front Of House
CUPERTINO
Building Department
OCT 1 4 2015
EVIEWED FOR CODE COMPLIANCE
Reviewed By:
TOTAL ARRAY AREA (SF): 272
TOTAL ROOF AREA (SF): 1823
TOTAL ARRAY AREA IS N 14.92
PERCENT OF TOTAL ROOF AREA
PITCH: 23 ARRAY PITCH: 23
MP1 AZIMUTH: 270 ARRAY AZIMUTH: 270
MATERIAL: Comp Shingle STORY: 1 Story
PITCH: 23 ARRAY PITCH: 23
MP2 AZIMUTH: 90 ARRAY AZIMUTH: 90
MATERIAL: Comp Shingle STORY: 1 Story
PITCH: 23 ARRAY PITCH: 23
MP3 AZIMUTH: 180 ARRAY AZIMUTH: 180
MATERIAL: Comp Shingle STORY: 1 Story
(E) UTILITY METER & WARNING LABEL
Inv INVERTER W/ INTEGRATED DC DISCO
& WARNING LABELS
SITE PLAN
Scale: 1/8" = 1'
0 1' 8' 16'
N
W E
S
CONFIDENTIAL —THE INFORMATION HEREIN
CONTAINED SHALL NOT BE USED FOR THE
JOB NUMBER: JB - 9506224 0 0
' PREMISE OWER. DESCRIPTION:
CHAVEZ, YUKARI CHAVEZ RESIDENCE
DESIGN:
F, ,^
U1tw F "'"h Inger
DC DISCONNECT & WARNING LABELS
A AC
AC DISCONNECT &WARNING LABELS
O
DC JUNCTION/COMBINER BOX & LABELS
DISTRIBUTION PANEL & LABELS
Lc
LOAD CENTER & WARNING LABELS
ODEDICATED
PV SYSTEM METER
0
STANDOFF LOCATIONS
—
CONDUIT RUN ON EXTERIOR
---
CONDUIT RUN ON INTERIOR
—
GATE/FENCE
0
HEAT PRODUCING VENTS ARE RED
F/ -_I+ 11
INTERIOR EQUIPMENT IS DASHED
L _ "J
SITE PLAN
Scale: 1/8" = 1'
0 1' 8' 16'
N
W E
S
CONFIDENTIAL —THE INFORMATION HEREIN
CONTAINED SHALL NOT BE USED FOR THE
JOB NUMBER: JB - 9506224 0 0
' PREMISE OWER. DESCRIPTION:
CHAVEZ, YUKARI CHAVEZ RESIDENCE
DESIGN:
F, ,^
U1tw F "'"h Inger
�;,;So�arCity.
MOUNTING SYSTEM:
Multiple Mounting Hardware Types
BENEFIT OF ANYONE EXCEPT SOLARCITY INC.,
NOR SHALL IT BE DISCLOSED IN WHOLE OR IN
21960 MCCLELLAN ROAD 3.9 KW PV ARRAY
�
PART OTHERS OUTSIDE THE RECIPIENTS
CUPERTINO CA 95014
MODULES
ORGANIZATION, EXCEPT IN CONNECTION WITH
THE SALE AND USE OF THE RESPECTIVE
(15) REC # REC260PEZSon
,
3055 Clearview Way
CA 94402
SHEET: REV: DATE
SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN
PERMISSION OF SOLARCITY INC.
PAGE NAME
4082524553 SITE PLAN
PV 2 10/13/2015
T:(650) 638-1028Mateo,
F.(650) 638-1029
(988)-SOL—CITY (765-2489) www.sdorcity.com
INVERTER:
SOLAREDGE # SE3800A—US—ZB—U
A)SIDE VIEW OF MPI
-�
NTS
MPJ
X -SPACING
X -CANTILEVER
Y -SPACING
Y -CANTILEVER
NOTES
LANDSCAPE
72
24"
RAFTER
C.J.
11
2x4 @ 24 OC
2x6 @16" OC
PORTRAIT
48
20"
RAFTER
C.J.
2x4 @ 24" OC
2X6 @16" OC
ROOF AZI 270 PITCH 23 STORIES: 1
ARRAY AZI 270 PITCH 23
Comp Shingle
rC--��SIDE VIEW OF MP3 NTS
MP3
X -SPACING X -CANTILEVER
Y -SPACING Y -CANTILEVER
NOTES
LANDSCAPE
72" 24"
LANDSCAPE
72"
PORTRAIT 48"2011
RAFTER
C.J.
11
2x4 @ 24 OC
2x6 @16" OC
ROOF AZI 180 PITCH 23
ARRAY AZI 180 PITCH 23 STORIES: 1
Comp Shingle
CONFIDENTIAL — THE INFORMATION HEREIN
CONTAINED SHALL NOT BE USED FOR THE
BENEFIT OF ANYONE EXCEPT SOLARCITY INC.,
NOR SHALL IT BE DISCLOSED IN WHOLE OR IN
PART TO OTHERS OUTSIDE THE RECIPIENTS
ORGANIZATION, EXCEPT IN CONNECTION WITH
THE SALE AND USE OF THE RESPECTIVE
SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN
PERMISSION OF SOLARCITY INC.
JOB NUMBER: JB -9506224 00
MOUNTING SYSTEM:
Multiple Mounting Hardware Types
MODULES
(15) REC # REC260PEZ
INVERTER:
SOLAREDGE # SE380OA—US—ZB—U
CHAVEZ, YUKARI
21960 MCCLELLAN ROAD
CUPERTINO, CA 95014
4082524553
&A
PV MODULE
r.3
CUPERTINO
Building Department
OCT 14 2015
REVIEWED FOR CODE COMPLIANCE
Reviewed By:
SIDE VIEW OF MP2 N.s
MP2
X -SPACING
X -CANTILEVER
Y -SPACING
Y -CANTILEVER
NOTES
LANDSCAPE
72"
24"
PORTRAIT
48"
20"
RAFTER
C.J.
2X4 @ 24" OC
2x6 @16" OC
ROOF AZI 90 PITCH 23 STORIES: 1
ARRAY AZI 90 PITCH 23
Comp Shingle
5/16" BOLT WITH LOCK
& FENDER WASHERS
ZEP LEVELING FOOT
ZEP ARRAY SKIRT
ZEP COMP MOUNT C
ZEP FLASHING C
(E) COMP. SHINGLE
(E) ROOF DECKING
5/16" DIA STAINLESS
STEEL LAG BOLT
WITH SEALING WASHER
(2-1/2" EMBED, MIN)
(E) RAFTER
CHAVEZ RESIDENCE
3.9 KW PV ARRAY
PAGE NAME
STRUCTURAL VIEWS
#_5TP�NDOFF
iifcJr' 7! �i;, ;y
INSTALLATION ORDER
LOCATE RAFTER, MARK HOLE
(1) LOCATION, AND DRILL PILOT
HOLE.
C(2) SEAL PILOT HOLE WITH
POLYURETHANE SEALANT.
(3) INSERT FLASHING.
(4) PLACE MOUNT.
(5) INSTALL LAG BOLT WITH
SEALING WASHER.
(6) INSTALL LEVELING FOOT WITH
BOLT & WASHERS.
SHEET REV. DATE:
PV 3 10/13/2015
Oil, City
3055 CleaNew Way
San Mateo, CA 94402
T:(650) 638-1028 F:(650) 638-1029
(888)—SOL—CITY (765-2489) www.solarcity.com
VENT SPANNING DETAIL
SOLAR PANEL
M
SOLAR MODULE
MOUNTING HARDWARE
(SEE STANDOFF DETAIL)
ROOFING MATERIAL
PLYWOOD
(E) RAFTER
SPANNING PHOTOVOLTAIC MODULES OVER VENTS
�I TC
2" MAX 2" MIN CLEAR SPAN
DIAMETER __�,TO UNDERSIDE
-_� OF MODULE
Ur
MINIMUM VENT HEIGHT IS 6" ABOVE THE SURFACE OF THE ROOF PER 2007 CPC SECTION 906.1.
6" MIN. VENT
HEIGHT FROM TOP
OF ROOFING MATERIAL
VENT PIPE
2013 CPC 310.5 STATES "NO FITTING, FIXTURE, AND PIPING CONNECTION, APPLIANCE, DEVICE, OR METHOD OF INSTALLATION THAT OBSTRUCTS
OR RETARDS THE FLOW OF WATER, WASTES, SEWAGE, OR AIR IN THE DRAINAGE OR VENTING SYSTEMS IN AN AMOUNT EXCEEDING THE NORMAL
FRICTIONAL RESISTANCE TO FLOW, SHALL BE USED UNLESS IT IS INDICATED AS ACCEPTABLE IN THIS CODE OR IS APPROVED IN ACCORDANCE
WITH SECTION 301.1 OF THIS CODE." FROM THIS SECTION, IT IS CLEAR THAT MOUNTING SOLAR MODULES OVER A VENT IN A MANNER THAT
WILL NOT HAVE A GREATER FRICTIONAL RESISTANCE TO AIR FLOW WOULD BE ACCEPTABLE.
EQUATIONS:
THE FRICTIONAL RESISTANCE TO FLOW IS DIRECTLY PROPORTIONAL TO THE AREA THAT THE AIR CAN FLOW THROUGH. IN THE VENT, THAT IS
THE CROSS-SECTIONAL AREA OF THE VENT PIPE:
Avent = 7T*R'
WHEN THE AIR EXITS THE VENT, THE AREA IT HAS TO FLOW THROUGH IS THE CIRCUMFERENCE OF THE VENT TIMES THE VERTICAL DISTANCE
BETWEEM THE VENT AND THE MODULE ABOVE (IN THIS CASE, WE ARE LEAVING THE DIAMETER BETWEEN THE TOP OF THE VENT AND THE
BOTTOM OF THE PANEL). THIS METHODOLOGY ASSUMES THE WORST CASE SCENARIO OF MOUNTING THE MODULES HORIZONTALLY OVER THE
VENT. IN ACTUALITY, THE MODULES WILL BE TILTED WHICH WILL OFFER MORE AREA FOR AIR TO FLOW THROUGH.
Agap = C*CLEARANCE = (7T*D)*D = (7T*2*R)*(2*R) = 4*71*R2 4*7T*R2 > 7T*R2
FROM THE EQUATIONS ABOVE, IT IS EVIDENT THAT MOUNTING THE MODULES IN THIS MANNER ALLOWS FOUR TIMES THE AMOUNT OF AIR FLOW
ABOVE THE VENT THAN IN THE VENT ITSELF.
VENT HEIGHT WILL BE A MINIMUM OF 6 INCHES ABOVE THE ROOF, OR THE MINIMUM VALUE ALLOWED BY LOCAL BUILDING CODE.
MINIMUM CLEARANCE BETWEEN THE TOP OF THE VENT AND THE BOTTOM OF THE SOLAR MODULE GLASS SHALL BE AT LEAST THE DIAMETER OF
THE VENT.
IN THE DIRECTION OF THE SLOPE OF THE ROOF, THERE SHALL BE A GAP OF AT LEAST 1/2 INCH BETWEEN MODULES.
THF ROOF SLOPF MAST HAVE A MINIMUM INCLINATION OF 10' OR THE PANELS MUST BE SLOPED AT A MINIMUM INCLINATION OF 10'.
UPLIFT CALCULATIONS
10.13.2015
SolarCi+` , PV System Structural Version #49.3
a `Y Desian Software
Project Information & Table
Of Contents
Risk Category:
BENEFIT OF ANYONE EXCEPT SOLARCITY INC.,
NOR SHALL IT BE DISCLOSED IN WHOLE OR INMultiple
II
��'�`
PV System Type
PART TO OTHERS OUTSIDE THE RECIPIENTS
SolarCity SleekMount—
Comp Roof
Comp Roof
(15) REC # REC260PEZ
Layers of Comp Roofinq
2
SHEET: REV: DATE
Roof Slope
PAGE NAME:
4082524553 UPLIFT CALCULATIONS
230
T.(650) 638-1028 F:(650) 638-1029
1 (888) -SCI -CITY (765-2489) www.solarcity.com
Rafter Spacing
24" O.C.
PV System Module Orientation
Landscape and Portrait
PV Module Area
266 sf
PV Module Width
39"
PV Module Length
66"
Standoff Attachment Hardware
Comp Mount Type C
Reduced Ground/Roof Live/Snow Loads
Ground Snow Load
pg
0.0 psf
ASCE Table 7-1
Surrounding Roof Snow
0.0 psf
ASCE Eq: 7.4-1
Roof Snow Over PV Modules
0.0 sf
ASCE Eq: 7.4-1
Wind Design Criteria
Wind Design Code
ASCE 7-10
Wind Design Method
Partially/Fully Enclosed Method
Basic Wind Speed
V
110 mph 26-5-1A
Exposure Category
C 'on 26.7
Roof Style
Gable Roofa A-2A/B/C-5A/B
Mean Roof Height
h
15 ft ; b ion 26.2
Effective Wind Area 1 Module
A
17-8 sf *? " 1509 .7.]
Wind Pressure Calculation Coefficients
Wind Pressure Exposure
Kz
0.85
bj30.3-1
Topographic Factor
Kzt
1.00 KEV
FAR r
Wind Directionality Factor
Kd
0.85
Section 26.6-1
Importance Factor
I
NA
ReVIewed 6,
Velocity Pressure
qh
qh = 0.00256 (Kz) (Kzt) (Kd) (V^2)
Equation 30.3-1
22.4 psf
Ext. Pressure Coefficient (Up)
GCp (Up)
-0.88
Fig. 30.4-2A/8/C-5A/B
Ext Pressure Coefficient Down
GC Down
0.45
Fg.30.4-2VB/C-5A/B
Design Wind Pressure
P
p = gh GC
Equation 30.4-1
Wind Pressure Up
p(up)
-19.6 psf
Wind Pressure Down
down
16.0 psf
Allowable Standoff Spacings
X -Direction
Y -Direction
Max Allowable Standoff Spacing
Landscape
72"
39"
Max Allowable Cantilever
Landscape
24"
NA
Standoff Configuration
Landscape
Not -Staggered
Max Standoff Tributary Area
Trib
20 sf
PV Assembly Dead Load
W -PV
3 psf
Net Wind Uplift at Standoff
T -actual
-197 lbs
Uplift Capacity of Standoff
T -allow
500 lbs
Standoff Demand/Capacity
DCR
39.3%
Max Allowable Standoff Spacing
Portrait
48"
66"
Max Allowable Cantilever
Portrait
20"
NA
Standoff Configuration
Portrait
Not -Staggered
Max Standoff Tributary Area
Trib
22 sf
PV Assembly Dead Load
W -PV
3 psf
Net Wind Uplift at Standoff
T -actual
-220 lbs
Uplift Capacity of Standoff
T -allow
500 lbs
Standoff Demand/Capacity
DCR
1 44.0%
CUPERTINO
Building Department
14 2015
-ODE COMPLIANCE
CONFIDENTIAL - THE INFORMATION HEREIN
CONTAINED SHALL NOT BE USED FOR THE
JOB NUMBER: JB -9506224 00
PREMISE ONMCR: DESCRIPTION:
CHAVEZ, YUKARI CHAVEZ RESIDENCE
DESIGN:
DESIGN:
Clor�hingpr
SolarCity.
MOUNTING SYSTEM:
Mounting Hardware Types
BENEFIT OF ANYONE EXCEPT SOLARCITY INC.,
NOR SHALL IT BE DISCLOSED IN WHOLE OR INMultiple
21960 MCCLELLAN ROAD 3.9 KW PV ARRAY
��'�`
PART TO OTHERS OUTSIDE THE RECIPIENTS
CUPERTINO CA 95014
MODULES
ORGANIZATION, EXCEPT IN CONNECTION WITH
THE SALE AND USE OF THE RESPECTIVE
(15) REC # REC260PEZ
3055 Clearview Way
Son Mateo, CA 94402
SHEET: REV: DATE
SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN
PERMISSION of SOLARCITY INC.
PAGE NAME:
4082524553 UPLIFT CALCULATIONS
PV 4 10/13/2015
T.(650) 638-1028 F:(650) 638-1029
1 (888) -SCI -CITY (765-2489) www.solarcity.com
INVERTER:
SOLAREDGE # SE380OA—US-ZB-U
GROUND SPECS
MAIN PANEL SPECS
GENERAL NOTES
INVERTER SPECS
MODULE SPECS
LICENSE
BOND (N) #8 GEC TO (N) GROUND ROD
Panel Number:NoMatch
Inv 1: DC Ungrounded
INV 1
— (1)SOLAREDGE ## SE380OA—US—ZB—U
LABEL: A
— (15)REC
## REC260PEZ
CA #888104
AT PANEL WITH IRREVERSIBLE CRIMP
Meter Number: 1006681035
Inverter; 38GOW, 240V, 97.5%; w/Unifed Disco and ZB, AFCI
PV
(nodule; 260W, 236.6W PTC,
MC4, 40mm, Black Frame, ZEP Enabled
C-10
INV 2
Underground Service Entrance
Voc: 37.8
Vpmox: 30.7
INV 3
Isc AND Imp
ARE SHOWN IN THE DC STRINGS IDENTIFIER
E 100A MAIN SERVICE PANEL
E 10OA/2P MAIN CIRCUIT BREAKER
Inverter 1
n
100A/2P
3
SOLAREDGE
SE380OA-US-ZB-U
DC: MP1 MP2: 1x7
DC-
(E) LOADS
L1
zaov
r---------------------
------------ EGC————————————— —----�
L2
DC,
I
20A/2P
A r--————————————
——————————————
N
_ EGC/
—————————————— — —— ——— GEC
DC-
---LDC+
DG-
I
2
C MP2,MP3: 1x8
9
I
__ EGC---
-----------------pj
I
I
(1) Conduit Kit; 3/4" EMT
N
I
I
EGCIGEC _
z z
cD
GEC
TO 120/240V
SINGLE PHASE
U1ILITY SERVICE I
I
CUPERTINO
Building Departrnent
OCT 14 2015
REVIEWED FOR CODE COMPLIANCE
Reviewed By:
Voc* = MAX VOC AT MIN TEMP
POI (1 ) UBI # UBIZO220 PV BCKFE D BREAKER
Breaker Zinsco RC Series; 20/2P; 1 ace
/fj
A
Pv
(15) SOLAREDGE 1P300-2NA4AZS DC
PowerBox G timizer, 30OW, H4, DC to DC, ZEP
— (1)Gro nd RoQ
5%8" 8, Copper
x
O3
R[(1)AWG #10, THWN-2, Black
(1 ) AWG #10, THWN-2, Red
(2) AWG #10, PV Wire, 60OV, Block Voc* = 500 VDC Isc = 15 ADC
O (1)AWG #10, THHN/THWN-2, Green EGC Vmp = 350 VDC Imp= 5.87 ADC
P..
L L
LL=.LL(1)AWG #10, THWN-2, White
NEUTRAL Vmp =240 VAC Imp=16 AAC
(1)Conduit Kit; 3/4" EMT
......................................................
- (1) AWG /8,. THAN -2,. Green _ .
EGC/GEC -(QConduit. Kit; . 3/4" EMT
(2) AWG #10, PV Wire, 60OV, Black Voc* = 500 VDC Isc = 15 ADC
(1)AWG X10, THHN/THWN-2, Green EGC Vmp = 350 VDC Imp= 5.87 ADC
(1) Conduit Kit;. 3/4" EMT .......................... ....... .
CONFIDENTIAL — THE INFORMATION HEREIN
CONTAINED SHALL NOT BE USED FOR THE
BENEFIT OF ANYONE EXCEPT SOLARCITY INC.,
ADB NUMBER: JB -9506224 O O
PREMISE OWNER:
CHAVEZ, YUKARI
DESCRIPTION:
CHAVEZ
RESIDENCE
DESIGN:
Drew Flerchinger
�\`,''
mo
S oIarCity,
MOUNTING SYSTEM:
WH
NOR SHALL IT BE DISCLOSED IN OLE OR IN
Multiple Mounting Hardware Types
21960 M(;CLLLLAN ROAD
3.9 KW
PV ARRAY
FIN
PART TO OTHERS OUTSIDE THE RECIPIENTS
CUPERTINO, CA 95014
MODULES:
3055 Cleornew Way
Son CA 94402
ORGANIZATION, EXCEPT IN CONNECTION WITH
THE SALE AND USE OF THE RESPECTIVE
(15) REC # REC260PEZ
SHEET: REV: DATE
SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN
PERMISSION OF SOLARCITY INC.
4082524553
PACE NAME
THREE LINE DIAGRAM
PV 5 10/13/2015
To.
: (650) 638-1028 F:(650) 638-1029
(868) -SOL -CITY (765-2489) www.solarcity.com
INVERTER:
SOLAREDGE# SE380OA-US-ZB-U
Label Location:
(C)(IC)(CB)
C;,
C 4
CRC R331.2
Label Location:
(DC) (INV)
Per Code:
CEC 690.14.C.2
Label Location:
(DC) (INV)
Per Code:
CEC 690.53
Label Location:
(DC) (CB)
Per Code:
CEC 690.17
Label Location:
(INV)
Per Code:
CEC 690.5(C)
Label Location:
(AC) (POI)
Per Code:
CEC 690.14.C.2
Label Location:
(AC) (POI)
Per Code:
CEC; 690.64
Label Location:
(AC)
Label Location:
(DC)
Per Code:
CEC 690.17
Label Location.-
(POI)
ocation:(POI)
Per Code:
CEC 705.12.D.7
Label Location:
(POI)
Per Code:
CEC 690.54; CEC 690.17
Label Location:
(D) (POI)
Per Code:
CEC 690.64.B.4
Label Location:
(POI)
Per Code:
r,Fi . 7n5 12. D.7
Label Location:
(DC)(INV)(CB)
Per Code:
r.Fr. Fqn 35(F)
TO BE USED WHEN
INVERTER IS
UNGROUNDED
CUPERTINO
Building Department
OCT 14 2015
REVIEWED FOR CODE COMPLIANCE
Reviewed By.
(AC): AC Disconnect
(C): Conduit
(CB): Combiner Box
(D): Distribution Panel
(DC): DC Disconnect
(IC): Interior Run Conduit
(INV): Inverter With Integrated DC Disconnect
(LC): Load Center
(M): Utility Meter
(PCI): Point of Interconnection
CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR I =�"i! 3055 Cleamew Way
THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED San Mateo, CA 94402
29
IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, Label Set �'�� -:(650) 638-1028 89) w) .solar it
EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE /9 S0lar'� (888)-SOL-CITYp65-2489)www.solarcity.com
SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC.
iSoiarCity ZepSolar
Zep System
for composition shin le roofs
p 9
Q"4314p41�6
h
�pOOMPPtl
UL LISTED
ETA
zepsolar.com
u,. 1
Next -Level PV Mounting Technology '4,SolarCity 1 ZepSolar
lGroundZep Interlock KY see sw,1nl
_ Leveling Foot - _ - _
Zcp Compatible• PY Module
h r
Zcp Growc
�. a Rmf Attachment
Array Sk(rl kp,9lgt
Description
• PV mounting solution for composition shingle roofs
• Works with all Zep Compatible Modules
• Auto bonding UL -listed hardware creates structual and electrical bond
• Zep System has a UL 1703 Class "A" Fire Rating when installed using
modules from any manufacturer certified as "Type 1" or "Type 2"
Specifications
• Designed for pitched roofs
• Installs in portrait and landscape orientations
• Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703
• Wind tunnel report to ASCE 7-05 and 7-10 standards
• Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467
• Zep System bonding products are UL listed to UL 2703
• Engineered for spans up to 72" and cantilevers up to 24"
• Zep wire management products listed to UL 1565 for wire positioning devices
• Attachment method UL listed to UL 2582 for Wind Driven Rain
This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for
each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely
responsible for verifying the suitability of Zep Solar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com.
Components
zepsolar.com
Next -Level PV Mounting Tcchnolog
Comp Mount
Part No. 850-1382
Listed to UL 2582 &
Mounting Block to UL 2703
f)
Ground Zep
Part No. 850-1172
Listed to UL 2703 and
ETL listed to UL 467
CUPERTINO
Building Department
00 T 1 4 2015
:D FOR CODE COMPLIANCE
ewed By: GGjG�Y --
Interlock Leveling Foot
Part No. 850-1388 Part No. 850-1397
Listed to UL 2703 Listed to UL 2703
Array Skirt, Grip, End Caps DC Wire Clip
Part Nos. 500-0113, Part No. 850-1448
850-1421, 850-1460, Listed UL 1565
850-1467
Listed to UL 2703
This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for
each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely
responsible for verifying the suitability of Zep Solar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com_
02 27 15 ZS for Comp Shingle Culsheet Rev 04.pdf Page: 1 of 2 02 27 15 ZS for Comp Shingle Cutsheet Rev 04.pdf Page: 2 of 2
solar- . •
SolarEdge Power Optimizer
Module Add -On For North America
P300 / P350 / P400
PV power optimization at the module -level
— Up to 25% more energy
- Superior efficiency (99.5%)
— Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading
— Flexible system design for maximum space utilization
— Fast installation with a single bolt
— Next generation maintenance with module -level monitoring
— Module -level voltage shutdown for installer and firefighter safety
USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA www.solaredge.us
�----� t; U P ER i i iv G
Building Department
OCT 14 2015
-:aEVIFiWED FOR CODE COMPLIANCE
solar =@@ SolarEdge Power Optimizer
Module Add -On for North America by
P300 / P350 / P400
P300 P350 P400
(for 60 -cell PV (for 72 -cell PV (for 96te11 PV
.modules) modules) modules)
- - --
INPUT
Rated Input DC Power"I 300 350 400 W
Absolute Maximum Input Voltage (Voc-at lowest temperature)...,.,,.,,., 48 .............. ......... 60.........,.,, ........... 80.............. Vdc
�8
MPPT Operating Range ........................................................ 8. ......... 8 �........ Vdc.....
Maximum Short Circuit Current (Isc) 10
.
Maximum DC Input Current 12S Adc
....................................................
............................................................................
,,Maxi . ............. ..........
Maximum Eficien........................................ 99S ... %......
Weighted Efficiency 98.8 % ..,.,
............................................................................................................................................
Overvoltage Category II
OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING INVERTER)
Maximum Output Current
15
Adc
.............................................................................
..... .nO Output
Maximum Out ut Volta a
60
Vdc
OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF)
Safety Output Voltage per Power Optimizer
STANDARD COMPLIANCE _
EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3
..................IEC62109-1(class
..Safery..................................................................
II safety),,UL1741.................. ...........
RoHS Yes
INSTALLATION SPECIFICATIONS
Maximum Allowed System VoltageVdc
.........................................................................1000
Dimenslons(Wxlx H).................................................................... 141x212x40.5/S.SSz8.34x1.59 mm/in..
.....................................................................
Weight (including cables)..................................................................................950 /.2. :1...................................... Hr / Ib...
Inpu[ Connector .............. MC4 / Amphenol / Tyco.................................. .
Output Wire Type /Connector Double Insulated; Amphenol
..Output,
W ire.Length.................................................. ..... :95..3: .......I.......................?:? x.3:9......................... /^.. ft....
Operating Temperature Ran. e....................................................................:40.185................................... �.....
Prote[tion Rating IP65 / NEMA4
Relative Humidit ..................................... 0:.100 %
^�sxed src vo.K, one.—I.,m 1d or.v1.5%+.kn .1—d.
---. __--- _.----------- --- ------- -----
PV SYSTEM DESIGN USING A SOLAREDGE SINGLE PHASE THREE PHASE THREE PHASE
INVERTER 208V 480V
Minimum String Leng[h (Power Optimizers)
....................................................................................................................
8 30 ..........................18..........................
Maximum String Length (Power Optimizers)
............................................................................................................................................................................
25 2550
Maximum Power per String
........................................................................................................................................................................
5250 6000 12750
W
Parallel Stringsof Different Lengths or Orientations
Yes
HIGH PERFORMANCE
SOLAR PANELS
REC PEAK
ENERGY
REC Peak Energy Z -Link Series solar
panels are the perfect choice for- building
solar systems that combine long lasting
product quality with reliable power output.
REC combines high quality design and
manufacturing standards to produce high-
performance solar panels with
uncompromising quality.
REC PEAK ENERGY Z -LINK
65.55 *0 1
1.38 _ 39-02
All measurements in inches
ELECTRICAL DATA @ STC REC26OPEZ
Nominal Power - P,n(Wp) 260
Watt Class Sorting-(Wp) /-5
Nominal Power Voltage -Vi,i,n(V) 307
Nominal Power Current -I. (A) 8.50
Open Circuit Voltage -Vi, (V) 37.8
Short Circuit Current -I. (A) 9.01
Panel Efficiency(%) 15.8
The electrical characteristics are within +/-10 % of the indicated values of Iic, Va and PMpp at standard Test conditions (STC).
Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W/ m', cell temperature 77°F (25'C)).
At low irradiance of 200 W/m' (AM 1.5 & cell temperature 77°F (259C)) at least 97% of the STC panel efficiency will be achieved.
l
CUPERTINO
I,trt Building Department
'WIES
t
14 2015
REVIEWED FOR CnDE COMPLIANCE
Reviewed By
FIRS -
H Y
YEAR PRODUCT WARRANTY
YEAR LINEAR POWER
OUTPUT WARRANTY
QrY"FR U5 IMPORT DUTY
FF
Nominal Operating Cell Temperature(NOCT)
45.7°C(±2°C)
O.a7
w
Temperature Coefficient ofVc,
-027%/°C
All measurements in inches
ELECTRICAL DATA @ STC REC26OPEZ
Nominal Power - P,n(Wp) 260
Watt Class Sorting-(Wp) /-5
Nominal Power Voltage -Vi,i,n(V) 307
Nominal Power Current -I. (A) 8.50
Open Circuit Voltage -Vi, (V) 37.8
Short Circuit Current -I. (A) 9.01
Panel Efficiency(%) 15.8
The electrical characteristics are within +/-10 % of the indicated values of Iic, Va and PMpp at standard Test conditions (STC).
Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W/ m', cell temperature 77°F (25'C)).
At low irradiance of 200 W/m' (AM 1.5 & cell temperature 77°F (259C)) at least 97% of the STC panel efficiency will be achieved.
l
CUPERTINO
I,trt Building Department
'WIES
t
14 2015
REVIEWED FOR CnDE COMPLIANCE
Reviewed By
FIRS -
H Y
YEAR PRODUCT WARRANTY
YEAR LINEAR POWER
OUTPUT WARRANTY
QrY"FR U5 IMPORT DUTY
FF
Nominal Operating Cell Temperature(NOCT)
45.7°C(±2°C)
Temperature Coefficient ofP1,t,P
-0.40%/°C
Temperature Coefficient ofVc,
-027%/°C
Temperature Coefficient of I,_c
0.024 %/°C
Cell Type:
60 REC PE multi-crystalt
3 strings of 20 cells with bypass diodes ',
Glass
0.125 in solar glass with anti -reflection
Nominal Power-P.,(Wp)
surface treatment
Back Sheet.
Double layer highlyresistantpolyester
Frame:
Anodized aluminum (black)
Maximum System Voltage:
Zep Groove compatible
Junction Box:
IP67 rated
Design Load:
0156 in (12 AWG) solar cable, 2 x 47.24 in
Connectors:
H4 Amphenol
Origin:
Made in Singapore
ELECTRICAL ..
Nominal Power-P.,(Wp)
197
OperationaITempe rature:
-40..+185°F(-40 +85°C)
Nominal Power Voltage - V,, (V)
29.0
Maximum System Voltage:
1000VUL
Nominal Power Current -IMrp(A)
6.81
Design Load:
50lbs/ftz(2400Pa) long side
Open Circuit Voltage -V,(V)
35.7
30Ihs/ft2 (1436 Pa) short side
Short Circuit Current -1,(A)
724
Max Series Fuse Rating:
ISA
Nominal operatmgcell temperature NOCT(800 W/m',AMI S. windspeed l m/s, ambient temperature 68°F(20°C).
Max Reverse Current
15A
MECHANICALDATA
10 year product warranty. Dimensions: 65.55 x 39.02 x 1.57 in (1665x 991 x40 mm)
c L us 25 year linear power output warranty Area 1775 ft 2(1,65 ma)
LISTEN (max. d egression in performance of 0.7% p.a.). Weight: 43Ins (19.5kg)
UL 1703, Fl rating. Type 1, Class C
Note! All given specifications are subject to change
without notice at anytime.
REC is a leading global provider of solar energy solutions. With more than 15 years of experience, we offer sustainable, high performing ^
products, services and investments for the solar industry.R
Together with our partners, we create value by providing solutions that better
meet the world's growing energy needs. REC is headquartered in Norway and listed on the Oslo Stock Exchange (ticker: RECSOL). Ourl,600
employees worldwide generated revenues of USD 647 million in 2013. www.recgroup.com
solar =@@
SolarEdge Single Phas(
For North America
SE3000A-US / SE380OA-US / SE5000A
SE760OA-US / SE10000A-US / SEI 1400
��v erten
:12.25
wa�ianbJ
9 �
s
dv�. Qi
a
i
The best choice for SolarEdge enabled systems
Integrated arc fault protection (Type 1) for NEC 2011 690.11 compliance
Superior efficiency (98%)
Small, lightweight and easy to install on provided bracket
Built-in module -level monitoring
Internet connection through Ethernet or Wireless
Outdoor and indoor installation
Fixed voltage inverter, DC/AC conversion only
Pre -assembled Safety Switch for faster installation
Optional — revenue grade data, ANSI C12.1
USA -GERMANY -ITALY -FRANCE -JAPAN -CHINA -AUSTRALIA - THE NETHERLANDS -ISRAEL www.solaredge.us
211- 240 -.264, Vac
AC Frequency Min: Nom: Max.l'I 59.3 - 60 - 60.5 (with HI country setting 57 - 60 - 60.5)
24 @ 208V 48 @ 20SV
Max. Continuous Output Current 12.5 16 25 32 47.5
................. I ....................... . 21, �° .240V .. .......... ........ ...42,@ 240y...
.............. ............... ...... ........
GFDI Threshold 1
. tiIIt............................................................................................................................................................
Utiliri Monitoring. Islandina Protection, Country Confiiturable Thresholds Yes
INPUT
Maximum DC Power (STC)
4050 5100 6750 8100 10250 13500 15350
............... ................. ........Yes .................... .................. .................
CUPERTINO
..Transformer -less Un rounded......
g.................
..............
...........
Building Department
solar=@9Single
Phase Inverters for North
SE3000A-US / SE3800A-US / SE5000A-US/ SE6000A-U
Nom. DC Input Voltage ..............
..................... ..
0tCi 14 2015
Vdc....
SE7600A- US/ SE10000A-US/SE1140OA-US REVIEWED
FOR CODE COMPLIANCE
Adc
......................................
................ . 15;5 240V. ..................................30;5 240V
—TSE3000A-US I
SE380OA-US I SESOOOA-US I SE6000A-US SE760OA-US SEIDDOOA-US-
45
OUTPUT
Reverse -Polarity Protection
Yes....ri....................................................
.............................................................
_
Nominal AC Power Output
........ ......... ...................
3000
3500
5000
6000
7600
.....
9980 @ 208V
.10000.@240V,
11400
..... ..
...
VA
...........
Max. AC Power Output
....................................
3300
................
4150
...............
5400 @ 208V
. 5450 240V
.........
6000
................................
8350
10800 @ 208V
10950 240V
......... .......
12000
..................
RS485, RS232, Ethernet, ZigBee (optional)
.................................................. ...............i3'.......................................................
VA
...........
AC Output Voltage Min. -Nom: Max.n)
Optional .............................i.......................
..........................................................
...........
✓
g....P
Functionalityenabled when SolarEdge rapid shutdown kit is installed
✓
Safety
UL1741, UL16998, UL1998, CSA 22.2
183 - 208 - 229 Vac
........................................................................................................................................
..................
IEEE1547
..........................................................................................................................
...........
Emissions
FCC art15 class B
INSTALLATION SPECIFICATIONS
AC output conduit size /AWG range
..........................................
3/4" minimum / 16-6 AWG
.......................... ...................................................................I
3/4" minimum / 8-3 AWG
................ I
AC Output Voltage Min: Nom: Max.l'I
✓
✓
✓
✓
✓
✓
✓
............................
Dimensions with Safety Switch
211- 240 -.264, Vac
AC Frequency Min: Nom: Max.l'I 59.3 - 60 - 60.5 (with HI country setting 57 - 60 - 60.5)
24 @ 208V 48 @ 20SV
Max. Continuous Output Current 12.5 16 25 32 47.5
................. I ....................... . 21, �° .240V .. .......... ........ ...42,@ 240y...
.............. ............... ...... ........
GFDI Threshold 1
. tiIIt............................................................................................................................................................
Utiliri Monitoring. Islandina Protection, Country Confiiturable Thresholds Yes
INPUT
Maximum DC Power (STC)
4050 5100 6750 8100 10250 13500 15350
............... ................. ........Yes .................... .................. .................
W
.........
..Transformer -less Un rounded......
g.................
..............
...........
...................r...
Max. Input Voltage
..........................................................................................................................
500 .........................:..................
Vdc
Nom. DC Input Voltage ..............
..................... ..
.. .. .. 325 @ 208V / 350 @ 240V
Vdc....
Max. Input Current
16.5 @ 208V 33 @ 208V
9.5 13 18 23 34.5
Adc
......................................
................ . 15;5 240V. ..................................30;5 240V
Max. Input Short Circuit Current
45
Adc
Reverse -Polarity Protection
Yes....ri....................................................
.............................................................
...........
Ground -Fault Isolation Detection
..Maximum
600ko Sensitivi
....98.2.... .....98.3..... .....98.3 .... .....98 .... ......98...... ......98 ......
....�.....
Inverter. Efficiency
..........
Weighted Efficiency
......97.7....
..CEC
...............
......97.5......1......98......1.998 ,Cal, 2408V .1......97.5.....1......97.5...... ..97.5Z240y..1.......97.5 ......
....�.....
Nighttime Power Consumption
<2.5 <4
W
ADDITIONAL FEATURES
Supported Communication Interfaces
............................ .. t rfa....
RS485, RS232, Ethernet, ZigBee (optional)
.................................................. ...............i3'.......................................................
...... ... ..
Revenue Grade Data, ANSI 012.1
. ...
Optional .............................i.......................
..........................................................
...........
Rapid Shutdown —NEC 2014 690.12
g....P
Functionalityenabled when SolarEdge rapid shutdown kit is installed
STANDARD COMPLIANCE
Safety
UL1741, UL16998, UL1998, CSA 22.2
Grid Connection Standards
.......................................
IEEE1547
..........................................................................................................................
...........
Emissions
FCC art15 class B
INSTALLATION SPECIFICATIONS
AC output conduit size /AWG range
..........................................
3/4" minimum / 16-6 AWG
.......................... ...................................................................I
3/4" minimum / 8-3 AWG
................ I
...........
DC input conduit size / p of strings J
3/4" minimum / 1-2 strings / 16-6 AWG
3/4" minimum / 1-2 strings /
. AWG range
14-6 AWG
............................
Dimensions with Safety Switch
.............................
.....................................................................................
30.Sx12.5x7.2/775x335x184
.......
30.5 x 12.5 x 10.5 /
...........
in /
HxWxP
........................................
...........................
.......... 775x,315x26Q.........
,_.mm,,,_
WeightwithSafetySwitch
.....................
,.....,,...:2/23.2 ....................:7/24.7
..... .................
88:4/40.1
...................
. Ib/kg
Natural
convection
Cooling Natural Convection and internal Fans (user replaceable)
fan (user
... ................... I................... ................................................................... .replaceable). .
...............................................
Noise <.25 <,50 dBA
Min. -Max. Operating Temperature -13 to +140 / 25 to +60 (-40 to +60 version available( )) 'F /'C
Ran e
Protection Rating NEMA 3R
...........................................................................................................................
For other regional settings please contact SolarEdge support.
1�1 A higher current source may be used; the inverter will limit its input current to the values stated.
i,l Revenue grade inverter P/N: SE."'"S000NNR2 (for 760OW inverten5E7600A-US002NNR2).
Rapid shutdown kit P/N: 5E30D0-RSD-51.
-40 version P/N: SE—ouk-US000NNU4 (for 760OW imener:SE7600A-US002NNU4).