Loading...
15100114I CITY OF CUPERTINO BUILDING PERMIT I I BUILDING ADDRESS: 21960 MCCLELLAN RD CONTRACTOR: SOLARCITY PERMIT NO: 15100114 I OWNER'S NAME: YKARI CHAVES 13055 CLEARVIEW WAY I DATE ISSUED: 10/14/2015 I OWNER'S PHONE: 4082524553 1 SAN MATEO, CA 94402 1 PHONE NO: (650) 638-1028 1 LICENSED CONTRACTOR'S DECLARATION License Class0_ 0­2(Lic. # 119i Contractor i) 10,x` f ") Date to i Ll /L) I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. JOB DESCRIPTION: RESIDENTIAL ❑ COMMERCIAL Q INSTALLATION 15 ROOFTOP FLUSH MOUNTED SOLAR PANEL (3.9KW) hereby affirm under penalty of perjury one of the following two declarations: Sq. Ft Floor Area: I have and will maintain a certificate of consent to self --insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the APN Number: 35608033.00 performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may acctue against said City in consequence of the granting of this permit. Additionally,applicant understands and will comply with all non -point source regulation aper tli Cupertino Municipal Code, Section 9.18. Signature f Date (� 1-, m 1 OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: 1. I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) 2. I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.7044, Business & Professions Code). I hereby affirm under penalty of perjury one of the following three declarations: t. I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. s. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Signature Date Valuation: $8500 Occupancy Type: PERMIT EXPIRES IF WORK IS NOT STARTED WITHIN 180 DAYS OF PERMIT ISSUANCE OR 180 DAYS AST CALLED _2�INSPECTION. Issued by: .2Date• / RE -ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. Signature of Applicant: Date: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER HAZARDOUS MATERIALS DISCLOSURE I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. Lwill maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Cod -Sects 25505, 25533, and 25534. Owner or ut a r t: Date: z CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name Lender's Address ARCHITECT'S DECLARATION I understand my plans shall be used as public records. Licensed Professional UM Ev� A `IR s s _. a-IUPERTINO PROJECT ADDRESS �$ / ®� �yfl F� I C_ CL 6r,) Pr`-� APN k 0 OWNER NAMEPHONE IBJ 4� E-MAIL r �d STREET ADDRESS r CITY, STATE, ZIP FAX t�U.V, Ck. � -i M fr 0 13 5o i CONTACT NAME Marian Javanmard PHGNE650.477.6430 i E-MAILmjavanmard@solarcity.com STREETADDREss391 Foster City Blvd CITY, STATE; ZIP Foster City, C/6 94404 FAX ❑ OWNER ❑ owNt ER -BUILDER ❑ OWNER AGENT ❑ CONTRACTOR ® CONTRACTOR AGENT ❑ ARCIffrECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME SolarCity Corporation LICENSE NUMBER 88F104 LICENSE TYPE C10 BUS. LIC k 28640 COMPANY NAMESolarCity Corporation F E-MAIL mjavanmaard@solarcity.com FAX STREETADDREss391 Foster City Blvd U CITY, STATE, ZIP Foster City, CA 94404 PH0N`650.477.6430 ARCHITECT/ENG(NEER NAME LICENSE NUMBER BUS. LIC COMPANY NAME E-MAIL. FAX STREET ADDRESS It USE OF Ed SFD Or Duplex ❑ Multi -Family STRUCTURE: ❑ Commercial CITY, STATE, ZIP PHONE' PROJECT IN WILDLAND PROJECT IN URBAN INTERFACE AREA ❑ Yes ❑ No FLOOD ZONE ❑ Yes ❑ No SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PA,VELS. NUMBER OF PANELS/UNITS: � 5 KILOWATTS (COMMERCIAL ONLY): j -'I DESCRIPTION OF WORK - Installation ( 15 ) rooftop flush mounted solar panel (3-. ) kW By my signature below, I certify to each of the following: I am application and the information I have provided is correct. I ha -V ordinances and state laws relating to building construction. I au Signature of Applicant/Agent: or authorized agent to act on the property o er's be al£ I have read this on of Work and verify it is accurate. I agree y with all applicable local es of Cupertino to enter the above -identified property for inspection purposes. Date: I r) 14 /1-5 .TION REQUIRED OFFICE USE ONLY ❑ OVER-TH&COUNTER F f .J ❑ EAPRESS U ❑ STANDARD U 2 ❑ LARGE c, ❑ MAJOR PYApp_2011.doc revised 03/16/11 CITY OF CUPERTINO FEE ESTIMATOR — BUILDING DIVISION ADDRESS: 21960 MCCELLAN RD DATE: 10/14/2015 REVIEWED BY: PHUONG APN 356-08-033 BP#: VALUATION: 1$8,500 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY SFD or Duplex PENTAMATION SOLAR -RES USE: PERMIT TYPE: WORK INSTALLATION 15 ROOFTOP FLUSH MOUNTED SOLAR PANEL 3.9kw SCOPE ,,Tech. i'lan (3,7eck FEE d'fxfO. 1 loo Ch Elec. ,P/17;i Check I hi(?f li. 1'e ft7 l 7 Li.': $0.00 = # $236.00 7'111 ti?J. N: if Fee: Suppl. PC Fee: Reg. 0 OT 1 I l,le c Permil Fee: 011lier AA --ch. Imp. I I I I o . I I I C,rhet l u��:<i Irr:s; C)fhe?• . lech. fayl-'. 14*ee: ( phulib. Tris. I Ins'Fee: NOTE: This estimate does not include fees due to other Departments r.e. Planninz, Public Works, Fire, Sanitary Sewer District, School rl:ctv:nt .#, 1 7%— 'r .,......., 1--1 -- f1... „1:..... 1-nntnrt tho I)vnt fpr addn'I info_ FEE ITEMS (Fee Resolution 11-053 Ef. . 711./13) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 = # $236.00 Alternative Energy System IPHQTOVRES Photovoltaic System Suppl. PC Fee: Reg. 0 OT 1 0. 01 hrs $0.00 PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Fee:19 Reg. 0 OT 0,0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 (1017shr vtiopz Achr ni5'tratile Fee: E) Work Without Permit? 0 Yes (j) No $0.00 Advanced Planning Fee: $0.00 Select a Non -Residential Building or Structure G A frUvel T�ocu me'nialion fees Strong Motion Fee: IBSEISMICR $1.11 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $1.00 SI7BTOTALS= $2.11 $236.00 TO�ALTET:: $238.11 Revised: 1U/U1izu'5 ABBREVIATIONS ELECTRICAL NOTES I JURISDICTION NOTES A AMPERE AC ALTERNATING CURRENT BLDG BUILDING CONC CONCRETE DC DIRECT CURRENT EGC EQUIPMENT GROUNDING CONDUCTOR (E) EXISTING EMT ELECTRICAL METALLIC TUBING FSB FIRE SET -BACK GALV GALVANIZED GEC GROUNDING ELECTRODE CONDUCTOR GND GROUND HDG HOT DIPPED GALVANIZED I CURRENT Imp CURRENT AT MAX POWER Isc SHORT CIRCUIT CURRENT kVA KILOVOLT AMPERE kW KILOWATT LBW LOAD BEARING WALL MIN MINIMUM (N) NEW NEUT NEUTRAL NTS NOT TO SCALE OC ON CENTER PL PROPERTY LINE POI POINT OF INTERCONNECTION PV PHOTOVOLTAIC SCH SCHEDULE S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT 1. THIS SYSTEM IS GRID-INTERTIED VIA A UL -LISTED f OWER-COND!T!ONING INVFRTFR. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. 3. A NATIONALLY -RECOGNIZED TESTING LABORATORY SHALL LIST ALL EQUIPMENT IN COMPLIANCE WITH ART. 110.3. 4. WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, A SIGN WILL BE PROVIDED WARNING OF THE HAZARDS PER ART. 690.17. 5. EACH UNGROUNDED CONDUCTOR OF THE MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY PHASE AND SYSTEM PER ART. 210.5. 6. CIRCUITS OVER 250V TO GROUND SHALL COMPLY WITH ART. 250.97, 250.92(B). 7. DC CONDUCTORS EITHER DO NOT ENTER BUILDING OR ARE RUN IN METALLIC RACEWAYS OR ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER ART. 690.31(E). 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY UL LISTING. 9. MODULE FRAMES SHALL BE GROUNDED AT THE UL -LISTED LOCATION PROVIDED BY THE MANUFACTURER USING UL LISTED GROUNDING HARDWARE. 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE BONDED WITH EQUIPMENT GROUND CONDUCTORS. LICENSE GENERAL NOTES CA # 888104 1. ALL WORK TO BE DONE TO THE 2013 C-10 CALIFORNIA BUILDING CODE AND THE 2013 CALIFORNIA RESIDENTIAL CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY THE 2013 CALIFORNIA ELECTRIC CODE. MODULE GROUNDING METHOD: ZEP SOLAR I AHJ: Cupertino FLASHING WILL BE PAINTED TO MATCH EXTERIOR UTILITY: Pacific Gas and Electric Company •� JB-9506224 00 `''IQ'E" CONFIDENTIAL —THE INFORMATION HEREIN [INVERTER: NUMBER: CHAVEZ, YUKARI CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR INultiple Mounting Hardware Types 21960 MCCLELLAN ROAD PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH ULES: CUPERTINO, C A 95014 THE SALE AND USE OF THE RESPECTIVE 5) REC # REC260PEZSOLAR�: PERMISSION EQUIPMENT, WITHOUT THE WRITTEN 4082524553 PERMISSION of soLARCITY lNc.LAREDGE # SE380OA-US-ZB-U — I CUPERTINO I Building Depatnent w .0 I QCT 1 4 2015 -ZEVIEVVED FOR CODE COMPLIANCE Reviewed By: —, COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION - CUPERTINO APPROVED This set of plans and specifications MUST be kept at the job site during construction. It is unlawful to make any changes or alterations on same, or to deviate therefrom, without approval from the Building Official. The Stamping of this plan and specifications SHALL NOT be held to permit or to be an approval of the violation any provi ' C B y Y ` ity Ordinance or State Law. Ei DATE U — PERMIT # _ V VICINITY MAP 0 DESCRIPTION: CHAVEZ RESIDENCE 3.9 KW PV ARRAY TMK OWNER: PACE NAME: COVER SHEET PIAT P NS C ECKED h y. DATE /0 /' o ls PLANNING DEPT CUPERTINO INDEX x-11 PV1 COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS "�. PV4 UPLIFT CALCULATIONS f iI PV5 THREE LINE DIAGRAM iII :- Cutsheets Attached a O V W U LL REV BY DATE COMMENTS REV A NAME DATE COMMENTS t ■ s s DESIGN: D. ew Flerchinger \\I,;SOIarCit ^� v J V 3055 Cleorview Way SHEET: REV: DATE San Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 PV 1 10/13/2015 (888)—SOL—CITY (765-2489) www.solarcity.com Front Of House CUPERTINO Building Department OCT 1 4 2015 EVIEWED FOR CODE COMPLIANCE Reviewed By: TOTAL ARRAY AREA (SF): 272 TOTAL ROOF AREA (SF): 1823 TOTAL ARRAY AREA IS N 14.92 PERCENT OF TOTAL ROOF AREA PITCH: 23 ARRAY PITCH: 23 MP1 AZIMUTH: 270 ARRAY AZIMUTH: 270 MATERIAL: Comp Shingle STORY: 1 Story PITCH: 23 ARRAY PITCH: 23 MP2 AZIMUTH: 90 ARRAY AZIMUTH: 90 MATERIAL: Comp Shingle STORY: 1 Story PITCH: 23 ARRAY PITCH: 23 MP3 AZIMUTH: 180 ARRAY AZIMUTH: 180 MATERIAL: Comp Shingle STORY: 1 Story (E) UTILITY METER & WARNING LABEL Inv INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS SITE PLAN Scale: 1/8" = 1' 0 1' 8' 16' N W E S CONFIDENTIAL —THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER: JB - 9506224 0 0 ' PREMISE OWER. DESCRIPTION: CHAVEZ, YUKARI CHAVEZ RESIDENCE DESIGN: F, ,^ U1tw F "'"h Inger DC DISCONNECT & WARNING LABELS A AC AC DISCONNECT &WARNING LABELS O DC JUNCTION/COMBINER BOX & LABELS DISTRIBUTION PANEL & LABELS Lc LOAD CENTER & WARNING LABELS ODEDICATED PV SYSTEM METER 0 STANDOFF LOCATIONS — CONDUIT RUN ON EXTERIOR --- CONDUIT RUN ON INTERIOR — GATE/FENCE 0 HEAT PRODUCING VENTS ARE RED F/ -_I+ 11 INTERIOR EQUIPMENT IS DASHED L _ "J SITE PLAN Scale: 1/8" = 1' 0 1' 8' 16' N W E S CONFIDENTIAL —THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER: JB - 9506224 0 0 ' PREMISE OWER. DESCRIPTION: CHAVEZ, YUKARI CHAVEZ RESIDENCE DESIGN: F, ,^ U1tw F "'"h Inger �;,;So�arCity. MOUNTING SYSTEM: Multiple Mounting Hardware Types BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN 21960 MCCLELLAN ROAD 3.9 KW PV ARRAY � PART OTHERS OUTSIDE THE RECIPIENTS CUPERTINO CA 95014 MODULES ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (15) REC # REC260PEZSon , 3055 Clearview Way CA 94402 SHEET: REV: DATE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. PAGE NAME 4082524553 SITE PLAN PV 2 10/13/2015 T:(650) 638-1028Mateo, F.(650) 638-1029 (988)-SOL—CITY (765-2489) www.sdorcity.com INVERTER: SOLAREDGE # SE3800A—US—ZB—U A)SIDE VIEW OF MPI -� NTS MPJ X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 72 24" RAFTER C.J. 11 2x4 @ 24 OC 2x6 @16" OC PORTRAIT 48 20" RAFTER C.J. 2x4 @ 24" OC 2X6 @16" OC ROOF AZI 270 PITCH 23 STORIES: 1 ARRAY AZI 270 PITCH 23 Comp Shingle rC--��SIDE VIEW OF MP3 NTS MP3 X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 72" 24" LANDSCAPE 72" PORTRAIT 48"2011 RAFTER C.J. 11 2x4 @ 24 OC 2x6 @16" OC ROOF AZI 180 PITCH 23 ARRAY AZI 180 PITCH 23 STORIES: 1 Comp Shingle CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER: JB -9506224 00 MOUNTING SYSTEM: Multiple Mounting Hardware Types MODULES (15) REC # REC260PEZ INVERTER: SOLAREDGE # SE380OA—US—ZB—U CHAVEZ, YUKARI 21960 MCCLELLAN ROAD CUPERTINO, CA 95014 4082524553 &A PV MODULE r.3 CUPERTINO Building Department OCT 14 2015 REVIEWED FOR CODE COMPLIANCE Reviewed By: SIDE VIEW OF MP2 N.s MP2 X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 72" 24" PORTRAIT 48" 20" RAFTER C.J. 2X4 @ 24" OC 2x6 @16" OC ROOF AZI 90 PITCH 23 STORIES: 1 ARRAY AZI 90 PITCH 23 Comp Shingle 5/16" BOLT WITH LOCK & FENDER WASHERS ZEP LEVELING FOOT ZEP ARRAY SKIRT ZEP COMP MOUNT C ZEP FLASHING C (E) COMP. SHINGLE (E) ROOF DECKING 5/16" DIA STAINLESS STEEL LAG BOLT WITH SEALING WASHER (2-1/2" EMBED, MIN) (E) RAFTER CHAVEZ RESIDENCE 3.9 KW PV ARRAY PAGE NAME STRUCTURAL VIEWS #_5TP�NDOFF iifcJr' 7! �i;, ;y INSTALLATION ORDER LOCATE RAFTER, MARK HOLE (1) LOCATION, AND DRILL PILOT HOLE. C(2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. (3) INSERT FLASHING. (4) PLACE MOUNT. (5) INSTALL LAG BOLT WITH SEALING WASHER. (6) INSTALL LEVELING FOOT WITH BOLT & WASHERS. SHEET REV. DATE: PV 3 10/13/2015 Oil, City 3055 CleaNew Way San Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 (888)—SOL—CITY (765-2489) www.solarcity.com VENT SPANNING DETAIL SOLAR PANEL M SOLAR MODULE MOUNTING HARDWARE (SEE STANDOFF DETAIL) ROOFING MATERIAL PLYWOOD (E) RAFTER SPANNING PHOTOVOLTAIC MODULES OVER VENTS �I TC 2" MAX 2" MIN CLEAR SPAN DIAMETER __�,TO UNDERSIDE -_� OF MODULE Ur MINIMUM VENT HEIGHT IS 6" ABOVE THE SURFACE OF THE ROOF PER 2007 CPC SECTION 906.1. 6" MIN. VENT HEIGHT FROM TOP OF ROOFING MATERIAL VENT PIPE 2013 CPC 310.5 STATES "NO FITTING, FIXTURE, AND PIPING CONNECTION, APPLIANCE, DEVICE, OR METHOD OF INSTALLATION THAT OBSTRUCTS OR RETARDS THE FLOW OF WATER, WASTES, SEWAGE, OR AIR IN THE DRAINAGE OR VENTING SYSTEMS IN AN AMOUNT EXCEEDING THE NORMAL FRICTIONAL RESISTANCE TO FLOW, SHALL BE USED UNLESS IT IS INDICATED AS ACCEPTABLE IN THIS CODE OR IS APPROVED IN ACCORDANCE WITH SECTION 301.1 OF THIS CODE." FROM THIS SECTION, IT IS CLEAR THAT MOUNTING SOLAR MODULES OVER A VENT IN A MANNER THAT WILL NOT HAVE A GREATER FRICTIONAL RESISTANCE TO AIR FLOW WOULD BE ACCEPTABLE. EQUATIONS: THE FRICTIONAL RESISTANCE TO FLOW IS DIRECTLY PROPORTIONAL TO THE AREA THAT THE AIR CAN FLOW THROUGH. IN THE VENT, THAT IS THE CROSS-SECTIONAL AREA OF THE VENT PIPE: Avent = 7T*R' WHEN THE AIR EXITS THE VENT, THE AREA IT HAS TO FLOW THROUGH IS THE CIRCUMFERENCE OF THE VENT TIMES THE VERTICAL DISTANCE BETWEEM THE VENT AND THE MODULE ABOVE (IN THIS CASE, WE ARE LEAVING THE DIAMETER BETWEEN THE TOP OF THE VENT AND THE BOTTOM OF THE PANEL). THIS METHODOLOGY ASSUMES THE WORST CASE SCENARIO OF MOUNTING THE MODULES HORIZONTALLY OVER THE VENT. IN ACTUALITY, THE MODULES WILL BE TILTED WHICH WILL OFFER MORE AREA FOR AIR TO FLOW THROUGH. Agap = C*CLEARANCE = (7T*D)*D = (7T*2*R)*(2*R) = 4*71*R2 4*7T*R2 > 7T*R2 FROM THE EQUATIONS ABOVE, IT IS EVIDENT THAT MOUNTING THE MODULES IN THIS MANNER ALLOWS FOUR TIMES THE AMOUNT OF AIR FLOW ABOVE THE VENT THAN IN THE VENT ITSELF. VENT HEIGHT WILL BE A MINIMUM OF 6 INCHES ABOVE THE ROOF, OR THE MINIMUM VALUE ALLOWED BY LOCAL BUILDING CODE. MINIMUM CLEARANCE BETWEEN THE TOP OF THE VENT AND THE BOTTOM OF THE SOLAR MODULE GLASS SHALL BE AT LEAST THE DIAMETER OF THE VENT. IN THE DIRECTION OF THE SLOPE OF THE ROOF, THERE SHALL BE A GAP OF AT LEAST 1/2 INCH BETWEEN MODULES. THF ROOF SLOPF MAST HAVE A MINIMUM INCLINATION OF 10' OR THE PANELS MUST BE SLOPED AT A MINIMUM INCLINATION OF 10'. UPLIFT CALCULATIONS 10.13.2015 SolarCi+` , PV System Structural Version #49.3 a `Y Desian Software Project Information & Table Of Contents Risk Category: BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR INMultiple II ��'�` PV System Type PART TO OTHERS OUTSIDE THE RECIPIENTS SolarCity SleekMount— Comp Roof Comp Roof (15) REC # REC260PEZ Layers of Comp Roofinq 2 SHEET: REV: DATE Roof Slope PAGE NAME: 4082524553 UPLIFT CALCULATIONS 230 T.(650) 638-1028 F:(650) 638-1029 1 (888) -SCI -CITY (765-2489) www.solarcity.com Rafter Spacing 24" O.C. PV System Module Orientation Landscape and Portrait PV Module Area 266 sf PV Module Width 39" PV Module Length 66" Standoff Attachment Hardware Comp Mount Type C Reduced Ground/Roof Live/Snow Loads Ground Snow Load pg 0.0 psf ASCE Table 7-1 Surrounding Roof Snow 0.0 psf ASCE Eq: 7.4-1 Roof Snow Over PV Modules 0.0 sf ASCE Eq: 7.4-1 Wind Design Criteria Wind Design Code ASCE 7-10 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 110 mph 26-5-1A Exposure Category C 'on 26.7 Roof Style Gable Roofa A-2A/B/C-5A/B Mean Roof Height h 15 ft ; b ion 26.2 Effective Wind Area 1 Module A 17-8 sf *? " 1509 .7.] Wind Pressure Calculation Coefficients Wind Pressure Exposure Kz 0.85 bj30.3-1 Topographic Factor Kzt 1.00 KEV FAR r Wind Directionality Factor Kd 0.85 Section 26.6-1 Importance Factor I NA ReVIewed 6, Velocity Pressure qh qh = 0.00256 (Kz) (Kzt) (Kd) (V^2) Equation 30.3-1 22.4 psf Ext. Pressure Coefficient (Up) GCp (Up) -0.88 Fig. 30.4-2A/8/C-5A/B Ext Pressure Coefficient Down GC Down 0.45 Fg.30.4-2VB/C-5A/B Design Wind Pressure P p = gh GC Equation 30.4-1 Wind Pressure Up p(up) -19.6 psf Wind Pressure Down down 16.0 psf Allowable Standoff Spacings X -Direction Y -Direction Max Allowable Standoff Spacing Landscape 72" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Not -Staggered Max Standoff Tributary Area Trib 20 sf PV Assembly Dead Load W -PV 3 psf Net Wind Uplift at Standoff T -actual -197 lbs Uplift Capacity of Standoff T -allow 500 lbs Standoff Demand/Capacity DCR 39.3% Max Allowable Standoff Spacing Portrait 48" 66" Max Allowable Cantilever Portrait 20" NA Standoff Configuration Portrait Not -Staggered Max Standoff Tributary Area Trib 22 sf PV Assembly Dead Load W -PV 3 psf Net Wind Uplift at Standoff T -actual -220 lbs Uplift Capacity of Standoff T -allow 500 lbs Standoff Demand/Capacity DCR 1 44.0% CUPERTINO Building Department 14 2015 -ODE COMPLIANCE CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER: JB -9506224 00 PREMISE ONMCR: DESCRIPTION: CHAVEZ, YUKARI CHAVEZ RESIDENCE DESIGN: DESIGN: Clor�hingpr SolarCity. MOUNTING SYSTEM: Mounting Hardware Types BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR INMultiple 21960 MCCLELLAN ROAD 3.9 KW PV ARRAY ��'�` PART TO OTHERS OUTSIDE THE RECIPIENTS CUPERTINO CA 95014 MODULES ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (15) REC # REC260PEZ 3055 Clearview Way Son Mateo, CA 94402 SHEET: REV: DATE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION of SOLARCITY INC. PAGE NAME: 4082524553 UPLIFT CALCULATIONS PV 4 10/13/2015 T.(650) 638-1028 F:(650) 638-1029 1 (888) -SCI -CITY (765-2489) www.solarcity.com INVERTER: SOLAREDGE # SE380OA—US-ZB-U GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (N) GROUND ROD Panel Number:NoMatch Inv 1: DC Ungrounded INV 1 — (1)SOLAREDGE ## SE380OA—US—ZB—U LABEL: A — (15)REC ## REC260PEZ CA #888104 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number: 1006681035 Inverter; 38GOW, 240V, 97.5%; w/Unifed Disco and ZB, AFCI PV (nodule; 260W, 236.6W PTC, MC4, 40mm, Black Frame, ZEP Enabled C-10 INV 2 Underground Service Entrance Voc: 37.8 Vpmox: 30.7 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 100A MAIN SERVICE PANEL E 10OA/2P MAIN CIRCUIT BREAKER Inverter 1 n 100A/2P 3 SOLAREDGE SE380OA-US-ZB-U DC: MP1 MP2: 1x7 DC- (E) LOADS L1 zaov r--------------------- ------------ EGC————————————— —----� L2 DC, I 20A/2P A r--———————————— —————————————— N _ EGC/ —————————————— — —— ——— GEC DC- ---LDC+ DG- I 2 C MP2,MP3: 1x8 9 I __ EGC--- -----------------pj I I (1) Conduit Kit; 3/4" EMT N I I EGCIGEC _ z z cD GEC TO 120/240V SINGLE PHASE U1ILITY SERVICE I I CUPERTINO Building Departrnent OCT 14 2015 REVIEWED FOR CODE COMPLIANCE Reviewed By: Voc* = MAX VOC AT MIN TEMP POI (1 ) UBI # UBIZO220 PV BCKFE D BREAKER Breaker Zinsco RC Series; 20/2P; 1 ace /fj A Pv (15) SOLAREDGE 1P300-2NA4AZS DC PowerBox G timizer, 30OW, H4, DC to DC, ZEP — (1)Gro nd RoQ 5%8" 8, Copper x O3 R[(1)AWG #10, THWN-2, Black (1 ) AWG #10, THWN-2, Red (2) AWG #10, PV Wire, 60OV, Block Voc* = 500 VDC Isc = 15 ADC O (1)AWG #10, THHN/THWN-2, Green EGC Vmp = 350 VDC Imp= 5.87 ADC P.. L L LL=.LL(1)AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=16 AAC (1)Conduit Kit; 3/4" EMT ...................................................... - (1) AWG /8,. THAN -2,. Green _ . EGC/GEC -(QConduit. Kit; . 3/4" EMT (2) AWG #10, PV Wire, 60OV, Black Voc* = 500 VDC Isc = 15 ADC (1)AWG X10, THHN/THWN-2, Green EGC Vmp = 350 VDC Imp= 5.87 ADC (1) Conduit Kit;. 3/4" EMT .......................... ....... . CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., ADB NUMBER: JB -9506224 O O PREMISE OWNER: CHAVEZ, YUKARI DESCRIPTION: CHAVEZ RESIDENCE DESIGN: Drew Flerchinger �\`,'' mo S oIarCity, MOUNTING SYSTEM: WH NOR SHALL IT BE DISCLOSED IN OLE OR IN Multiple Mounting Hardware Types 21960 M(;CLLLLAN ROAD 3.9 KW PV ARRAY FIN PART TO OTHERS OUTSIDE THE RECIPIENTS CUPERTINO, CA 95014 MODULES: 3055 Cleornew Way Son CA 94402 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (15) REC # REC260PEZ SHEET: REV: DATE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. 4082524553 PACE NAME THREE LINE DIAGRAM PV 5 10/13/2015 To. : (650) 638-1028 F:(650) 638-1029 (868) -SOL -CITY (765-2489) www.solarcity.com INVERTER: SOLAREDGE# SE380OA-US-ZB-U Label Location: (C)(IC)(CB) C;, C 4 CRC R331.2 Label Location: (DC) (INV) Per Code: CEC 690.14.C.2 Label Location: (DC) (INV) Per Code: CEC 690.53 Label Location: (DC) (CB) Per Code: CEC 690.17 Label Location: (INV) Per Code: CEC 690.5(C) Label Location: (AC) (POI) Per Code: CEC 690.14.C.2 Label Location: (AC) (POI) Per Code: CEC; 690.64 Label Location: (AC) Label Location: (DC) Per Code: CEC 690.17 Label Location.- (POI) ocation:(POI) Per Code: CEC 705.12.D.7 Label Location: (POI) Per Code: CEC 690.54; CEC 690.17 Label Location: (D) (POI) Per Code: CEC 690.64.B.4 Label Location: (POI) Per Code: r,Fi . 7n5 12. D.7 Label Location: (DC)(INV)(CB) Per Code: r.Fr. Fqn 35(F) TO BE USED WHEN INVERTER IS UNGROUNDED CUPERTINO Building Department OCT 14 2015 REVIEWED FOR CODE COMPLIANCE Reviewed By. (AC): AC Disconnect (C): Conduit (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit (INV): Inverter With Integrated DC Disconnect (LC): Load Center (M): Utility Meter (PCI): Point of Interconnection CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR I =�"i! 3055 Cleamew Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED San Mateo, CA 94402 29 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, Label Set �'�� -:(650) 638-1028 89) w) .solar it EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE /9 S0lar'� (888)-SOL-CITYp65-2489)www.solarcity.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. i­SoiarCity ZepSolar Zep System for composition shin le roofs p 9 Q"4314p41�6 h �pOOMPPtl UL LISTED ETA zepsolar.com u,. 1 Next -Level PV Mounting Technology '4,SolarCity 1 ZepSolar lGroundZep Interlock KY see sw,1nl _ Leveling Foot - _ - _ Zcp Compatible• PY Module h r Zcp Growc �. a Rmf Attachment Array Sk(rl kp,9lgt Description • PV mounting solution for composition shingle roofs • Works with all Zep Compatible Modules • Auto bonding UL -listed hardware creates structual and electrical bond • Zep System has a UL 1703 Class "A" Fire Rating when installed using modules from any manufacturer certified as "Type 1" or "Type 2" Specifications • Designed for pitched roofs • Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467 • Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72" and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices • Attachment method UL listed to UL 2582 for Wind Driven Rain This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of Zep Solar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. Components zepsolar.com Next -Level PV Mounting Tcchnolog Comp Mount Part No. 850-1382 Listed to UL 2582 & Mounting Block to UL 2703 f) Ground Zep Part No. 850-1172 Listed to UL 2703 and ETL listed to UL 467 CUPERTINO Building Department 00 T 1 4 2015 :D FOR CODE COMPLIANCE ewed By: GGjG�Y -- Interlock Leveling Foot Part No. 850-1388 Part No. 850-1397 Listed to UL 2703 Listed to UL 2703 Array Skirt, Grip, End Caps DC Wire Clip Part Nos. 500-0113, Part No. 850-1448 850-1421, 850-1460, Listed UL 1565 850-1467 Listed to UL 2703 This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of Zep Solar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com_ 02 27 15 ZS for Comp Shingle Culsheet Rev 04.pdf Page: 1 of 2 02 27 15 ZS for Comp Shingle Cutsheet Rev 04.pdf Page: 2 of 2 solar- . • SolarEdge Power Optimizer Module Add -On For North America P300 / P350 / P400 PV power optimization at the module -level — Up to 25% more energy - Superior efficiency (99.5%) — Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading — Flexible system design for maximum space utilization — Fast installation with a single bolt — Next generation maintenance with module -level monitoring — Module -level voltage shutdown for installer and firefighter safety USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA www.solaredge.us �----� t; U P ER i i iv G Building Department OCT 14 2015 -:aEVIFiWED FOR CODE COMPLIANCE solar =@@ SolarEdge Power Optimizer Module Add -On for North America by P300 / P350 / P400 P300 P350 P400 (for 60 -cell PV (for 72 -cell PV (for 96te11 PV .modules) modules) modules) - - -- INPUT Rated Input DC Power"I 300 350 400 W Absolute Maximum Input Voltage (Voc-at lowest temperature)...,.,,.,,., 48 .............. ......... 60.........,.,, ........... 80.............. Vdc �8 MPPT Operating Range ........................................................ 8. ......... 8 �........ Vdc..... Maximum Short Circuit Current (Isc) 10 . Maximum DC Input Current 12S Adc .................................................... ............................................................................ ,,Maxi . ............. .......... Maximum Eficien........................................ 99S ... %...... Weighted Efficiency 98.8 % ..,., ............................................................................................................................................ Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) Maximum Output Current 15 Adc ............................................................................. ..... .nO Output Maximum Out ut Volta a 60 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer STANDARD COMPLIANCE _ EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 ..................IEC62109-1(class ..Safery.................................................................. II safety),,UL1741.................. ........... RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System VoltageVdc .........................................................................1000 Dimenslons(Wxlx H).................................................................... 141x212x40.5/S.SSz8.34x1.59 mm/in.. ..................................................................... Weight (including cables)..................................................................................950 /.2. :1...................................... Hr / Ib... Inpu[ Connector .............. MC4 / Amphenol / Tyco.................................. . Output Wire Type /Connector Double Insulated; Amphenol ..Output, W ire.Length.................................................. ..... :95..3: .......I.......................?:? x.3:9......................... /^.. ft.... Operating Temperature Ran. e....................................................................:40.185................................... �..... Prote[tion Rating IP65 / NEMA4 Relative Humidit ..................................... 0:.100 % ^�sxed src vo.K, one.—I.,m 1d or.v1.5%­+.kn .1—d. ---. __--- _.----------- --- ------- ----- PV SYSTEM DESIGN USING A SOLAREDGE SINGLE PHASE THREE PHASE THREE PHASE INVERTER 208V 480V Minimum String Leng[h (Power Optimizers) .................................................................................................................... 8 30 ..........................18.......................... Maximum String Length (Power Optimizers) ............................................................................................................................................................................ 25 2550 Maximum Power per String ........................................................................................................................................................................ 5250 6000 12750 W Parallel Stringsof Different Lengths or Orientations Yes HIGH PERFORMANCE SOLAR PANELS REC PEAK ENERGY REC Peak Energy Z -Link Series solar panels are the perfect choice for- building solar systems that combine long lasting product quality with reliable power output. REC combines high quality design and manufacturing standards to produce high- performance solar panels with uncompromising quality. REC PEAK ENERGY Z -LINK 65.55 *0 1 1.38 _ 39-02 All measurements in inches ELECTRICAL DATA @ STC REC26OPEZ Nominal Power - P,n(Wp) 260 Watt Class Sorting-(Wp) /-5 Nominal Power Voltage -Vi,i,n(V) 307 Nominal Power Current -I. (A) 8.50 Open Circuit Voltage -Vi, (V) 37.8 Short Circuit Current -I. (A) 9.01 Panel Efficiency(%) 15.8 The electrical characteristics are within +/-10 % of the indicated values of Iic, Va and PMpp at standard Test conditions (STC). Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W/ m', cell temperature 77°F (25'C)). At low irradiance of 200 W/m' (AM 1.5 & cell temperature 77°F (259C)) at least 97% of the STC panel efficiency will be achieved. l CUPERTINO I,trt Building Department 'WIES t 14 2015 REVIEWED FOR CnDE COMPLIANCE Reviewed By FIRS - H Y YEAR PRODUCT WARRANTY YEAR LINEAR POWER OUTPUT WARRANTY QrY"FR U5 IMPORT DUTY FF Nominal Operating Cell Temperature(NOCT) 45.7°C(±2°C) O.a7 w Temperature Coefficient ofVc, -027%/°C All measurements in inches ELECTRICAL DATA @ STC REC26OPEZ Nominal Power - P,n(Wp) 260 Watt Class Sorting-(Wp) /-5 Nominal Power Voltage -Vi,i,n(V) 307 Nominal Power Current -I. (A) 8.50 Open Circuit Voltage -Vi, (V) 37.8 Short Circuit Current -I. (A) 9.01 Panel Efficiency(%) 15.8 The electrical characteristics are within +/-10 % of the indicated values of Iic, Va and PMpp at standard Test conditions (STC). Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W/ m', cell temperature 77°F (25'C)). At low irradiance of 200 W/m' (AM 1.5 & cell temperature 77°F (259C)) at least 97% of the STC panel efficiency will be achieved. l CUPERTINO I,trt Building Department 'WIES t 14 2015 REVIEWED FOR CnDE COMPLIANCE Reviewed By FIRS - H Y YEAR PRODUCT WARRANTY YEAR LINEAR POWER OUTPUT WARRANTY QrY"FR U5 IMPORT DUTY FF Nominal Operating Cell Temperature(NOCT) 45.7°C(±2°C) Temperature Coefficient ofP1,t,P -0.40%/°C Temperature Coefficient ofVc, -027%/°C Temperature Coefficient of I,_c 0.024 %/°C Cell Type: 60 REC PE multi-crystalt 3 strings of 20 cells with bypass diodes ', Glass 0.125 in solar glass with anti -reflection Nominal Power-P.,(Wp) surface treatment Back Sheet. Double layer highlyresistantpolyester Frame: Anodized aluminum (black) Maximum System Voltage: Zep Groove compatible Junction Box: IP67 rated Design Load: 0156 in (12 AWG) solar cable, 2 x 47.24 in Connectors: H4 Amphenol Origin: Made in Singapore ELECTRICAL .. Nominal Power-P.,(Wp) 197 OperationaITempe rature: -40..+185°F(-40 +85°C) Nominal Power Voltage - V,, (V) 29.0 Maximum System Voltage: 1000VUL Nominal Power Current -IMrp(A) 6.81 Design Load: 50lbs/ftz(2400Pa) long side Open Circuit Voltage -V,(V) 35.7 30Ihs/ft2 (1436 Pa) short side Short Circuit Current -1,(A) 724 Max Series Fuse Rating: ISA Nominal operatmgcell temperature NOCT(800 W/m',AMI S. windspeed l m/s, ambient temperature 68°F(20°C). Max Reverse Current 15A MECHANICALDATA 10 year product warranty. Dimensions: 65.55 x 39.02 x 1.57 in (1665x 991 x40 mm) c L us 25 year linear power output warranty Area 1775 ft 2(1,65 ma) LISTEN (max. d egression in performance of 0.7% p.a.). Weight: 43Ins (19.5kg) UL 1703, Fl rating. Type 1, Class C Note! All given specifications are subject to change without notice at anytime. REC is a leading global provider of solar energy solutions. With more than 15 years of experience, we offer sustainable, high performing ^ products, services and investments for the solar industry.R Together with our partners, we create value by providing solutions that better meet the world's growing energy needs. REC is headquartered in Norway and listed on the Oslo Stock Exchange (ticker: RECSOL). Ourl,600 employees worldwide generated revenues of USD 647 million in 2013. www.recgroup.com solar =@@ SolarEdge Single Phas( For North America SE3000A-US / SE380OA-US / SE5000A SE760OA-US / SE10000A-US / SEI 1400 ��v erten :12.25 wa�ianbJ 9 � s dv�. Qi a i The best choice for SolarEdge enabled systems Integrated arc fault protection (Type 1) for NEC 2011 690.11 compliance Superior efficiency (98%) Small, lightweight and easy to install on provided bracket Built-in module -level monitoring Internet connection through Ethernet or Wireless Outdoor and indoor installation Fixed voltage inverter, DC/AC conversion only Pre -assembled Safety Switch for faster installation Optional — revenue grade data, ANSI C12.1 USA -GERMANY -ITALY -FRANCE -JAPAN -CHINA -AUSTRALIA - THE NETHERLANDS -ISRAEL www.solaredge.us 211- 240 -.264, Vac AC Frequency Min: Nom: Max.l'I 59.3 - 60 - 60.5 (with HI country setting 57 - 60 - 60.5) 24 @ 208V 48 @ 20SV Max. Continuous Output Current 12.5 16 25 32 47.5 ................. I ....................... . 21, �° .240V .. .......... ........ ...42,@ 240y... .............. ............... ...... ........ GFDI Threshold 1 . tiIIt............................................................................................................................................................ Utiliri Monitoring. Islandina Protection, Country Confiiturable Thresholds Yes INPUT Maximum DC Power (STC) 4050 5100 6750 8100 10250 13500 15350 ............... ................. ........Yes .................... .................. ................. CUPERTINO ..Transformer -less Un rounded...... g................. .............. ........... Building Department solar=@9Single Phase Inverters for North SE3000A-US / SE3800A-US / SE5000A-US/ SE6000A-U Nom. DC Input Voltage .............. ..................... .. 0tCi 14 2015 Vdc.... SE7600A- US/ SE10000A-US/SE1140OA-US REVIEWED FOR CODE COMPLIANCE Adc ...................................... ................ . 15;5 240V. ..................................30;5 240V —TSE3000A-US I SE380OA-US I SESOOOA-US I SE6000A-US SE760OA-US SEIDDOOA-US- 45 OUTPUT Reverse -Polarity Protection Yes....ri.................................................... ............................................................. _ Nominal AC Power Output ........ ......... ................... 3000 3500 5000 6000 7600 ..... 9980 @ 208V .10000.@240V, 11400 ..... .. ... VA ........... Max. AC Power Output .................................... 3300 ................ 4150 ............... 5400 @ 208V . 5450 240V ......... 6000 ................................ 8350 10800 @ 208V 10950 240V ......... ....... 12000 .................. RS485, RS232, Ethernet, ZigBee (optional) .................................................. ...............i3'....................................................... VA ........... AC Output Voltage Min. -Nom: Max.n) Optional .............................i....................... .......................................................... ........... ✓ g....P Functionalityenabled when SolarEdge rapid shutdown kit is installed ✓ Safety UL1741, UL16998, UL1998, CSA 22.2 183 - 208 - 229 Vac ........................................................................................................................................ .................. IEEE1547 .......................................................................................................................... ........... Emissions FCC art15 class B INSTALLATION SPECIFICATIONS AC output conduit size /AWG range .......................................... 3/4" minimum / 16-6 AWG .......................... ...................................................................I 3/4" minimum / 8-3 AWG ................ I AC Output Voltage Min: Nom: Max.l'I ✓ ✓ ✓ ✓ ✓ ✓ ✓ ............................ Dimensions with Safety Switch 211- 240 -.264, Vac AC Frequency Min: Nom: Max.l'I 59.3 - 60 - 60.5 (with HI country setting 57 - 60 - 60.5) 24 @ 208V 48 @ 20SV Max. Continuous Output Current 12.5 16 25 32 47.5 ................. I ....................... . 21, �° .240V .. .......... ........ ...42,@ 240y... .............. ............... ...... ........ GFDI Threshold 1 . tiIIt............................................................................................................................................................ Utiliri Monitoring. Islandina Protection, Country Confiiturable Thresholds Yes INPUT Maximum DC Power (STC) 4050 5100 6750 8100 10250 13500 15350 ............... ................. ........Yes .................... .................. ................. W ......... ..Transformer -less Un rounded...... g................. .............. ........... ...................r... Max. Input Voltage .......................................................................................................................... 500 .........................:.................. Vdc Nom. DC Input Voltage .............. ..................... .. .. .. .. 325 @ 208V / 350 @ 240V Vdc.... Max. Input Current 16.5 @ 208V 33 @ 208V 9.5 13 18 23 34.5 Adc ...................................... ................ . 15;5 240V. ..................................30;5 240V Max. Input Short Circuit Current 45 Adc Reverse -Polarity Protection Yes....ri.................................................... ............................................................. ........... Ground -Fault Isolation Detection ..Maximum 600ko Sensitivi ....98.2.... .....98.3..... .....98.3 .... .....98 .... ......98...... ......98 ...... ....�..... Inverter. Efficiency .......... Weighted Efficiency ......97.7.... ..CEC ............... ......97.5......1......98......1.998 ,Cal, 2408V .1......97.5.....1......97.5...... ..97.5Z240y..1.......97.5 ...... ....�..... Nighttime Power Consumption <2.5 <4 W ADDITIONAL FEATURES Supported Communication Interfaces ............................ .. t rfa.... RS485, RS232, Ethernet, ZigBee (optional) .................................................. ...............i3'....................................................... ...... ... .. Revenue Grade Data, ANSI 012.1 . ... Optional .............................i....................... .......................................................... ........... Rapid Shutdown —NEC 2014 690.12 g....P Functionalityenabled when SolarEdge rapid shutdown kit is installed STANDARD COMPLIANCE Safety UL1741, UL16998, UL1998, CSA 22.2 Grid Connection Standards ....................................... IEEE1547 .......................................................................................................................... ........... Emissions FCC art15 class B INSTALLATION SPECIFICATIONS AC output conduit size /AWG range .......................................... 3/4" minimum / 16-6 AWG .......................... ...................................................................I 3/4" minimum / 8-3 AWG ................ I ........... DC input conduit size / p of strings J 3/4" minimum / 1-2 strings / 16-6 AWG 3/4" minimum / 1-2 strings / . AWG range 14-6 AWG ............................ Dimensions with Safety Switch ............................. ..................................................................................... 30.Sx12.5x7.2/775x335x184 ....... 30.5 x 12.5 x 10.5 / ........... in / HxWxP ........................................ ........................... .......... 775x,315x26Q......... ,_.mm,,,_ WeightwithSafetySwitch ..................... ,.....,,...:2/23.2 ....................:7/24.7 ..... ................. 88:4/40.1 ................... . Ib/kg Natural convection Cooling Natural Convection and internal Fans (user replaceable) fan (user ... ................... I................... ................................................................... .replaceable). . ............................................... Noise <.25 <,50 dBA Min. -Max. Operating Temperature -13 to +140 / 25 to +60 (-40 to +60 version available( )) 'F /'C Ran e Protection Rating NEMA 3R ........................................................................................................................... For other regional settings please contact SolarEdge support. 1�1 A higher current source may be used; the inverter will limit its input current to the values stated. i,l Revenue grade inverter P/N: SE."'"S000NNR2 (for 760OW inverten5E7600A-US002NNR2). Rapid shutdown kit P/N: 5E30D0-RSD-51. -40 version P/N: SE—ouk-US000NNU4 (for 760OW imener:SE7600A-US002NNU4).